mibs/MIBS/zyxel/ZYXEL-MGS3712-MIB
2023-12-05 12:25:34 +01:00

8997 lines
260 KiB
Plaintext

-- ZyXEL Communications Corporation
-- Private Enterprise MIB definition
-- This file describes the ZyXEL Communications Corporation Enterprise MIB.
-- It contains ZyXEL products OIDs, and common managed objects.
ZYXEL-MGS3712-MIB DEFINITIONS ::= BEGIN
IMPORTS
enterprises FROM RFC1155-SMI
OBJECT-TYPE
FROM SNMPv2-SMI -- RFC2578
RowStatus, DateAndTime, TruthValue, StorageType, MacAddress
FROM SNMPv2-TC -- RFC2579
DisplayString
FROM RFC1213-MIB
EnabledStatus
FROM P-BRIDGE-MIB
PortList
FROM Q-BRIDGE-MIB
dot1dBasePort
FROM BRIDGE-MIB
InterfaceIndexOrZero -- RFC2863
FROM IF-MIB
SnmpAdminString
FROM SNMP-FRAMEWORK-MIB -- RFC2571
InetAddressType, InetAddress
FROM INET-ADDRESS-MIB -- RFC2851
OperationResponseStatus
FROM DISMAN-PING-MIB
dot1agCfmMdIndex
FROM IEEE8021-CFM-MIB
dot1agCfmMaIndex
FROM IEEE8021-CFM-MIB
dot1agCfmMepIdentifier
FROM IEEE8021-CFM-MIB
IpAddress
FROM SNMPv2-SMI
ifIndex
FROM IF-MIB
-- from [RFC2863]
NOTIFICATION-TYPE
FROM SNMPv2-SMI
sysObjectID
FROM RFC1213-MIB
Counter, TimeTicks
FROM RFC1155-SMI
BridgeId, Timeout
FROM BRIDGE-MIB;
zyxel OBJECT IDENTIFIER ::= { enterprises 890 }
products OBJECT IDENTIFIER ::= { zyxel 1 }
accessSwitch OBJECT IDENTIFIER ::= { products 5 }
esSeries OBJECT IDENTIFIER ::= { accessSwitch 8 }
mgs3712 OBJECT IDENTIFIER ::= { esSeries 47 }
-- sysInfo
sysInfo OBJECT IDENTIFIER ::= { mgs3712 1 }
sysSwPlatformMajorVers OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SW platform major version, e.g. 3."
::= { sysInfo 1 }
sysSwPlatformMinorVers OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SW platform minor version, e.g. 50."
::= { sysInfo 2 }
sysSwModelString OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Model letters, e.g. TJ"
::= { sysInfo 3 }
sysSwVersionControlNbr OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Version control number, e.g. 0."
::= { sysInfo 4 }
sysSwDay OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SW compilation day, e.g. 19."
::= { sysInfo 5 }
sysSwMonth OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SW compilation month, e.g. 8."
::= { sysInfo 6 }
sysSwYear OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SW compilation year, e.g. 2004."
::= { sysInfo 7 }
sysHwMajorVers OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"HW major version number, e.g. 1."
::= { sysInfo 8 }
sysHwMinorVers OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"HW minor version number, e.g. 0."
::= { sysInfo 9 }
sysSerialNumber OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Serial number"
::= { sysInfo 10 }
sysSwBootUpImage OBJECT-TYPE
SYNTAX INTEGER{
image_1(1),
image_2(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current system boot up image,
You can change the boot up image of next rebooting by setting sysMgmtBootupImage."
::= { sysInfo 11 }
-- rateLimitSetup
rateLimitSetup OBJECT IDENTIFIER ::= { mgs3712 2 }
rateLimitState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Ingress/egress rate limiting enabled/disabled for the switch."
::= { rateLimitSetup 1 }
-- rateLimitPortTable
rateLimitPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF RateLimitPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { rateLimitSetup 2 }
rateLimitPortEntry OBJECT-TYPE
SYNTAX RateLimitPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in rateLimitPortTable."
INDEX { dot1dBasePort }
::= { rateLimitPortTable 1 }
RateLimitPortEntry ::=
SEQUENCE {
rateLimitPortState EnabledStatus,
rateLimitPortPeakRate INTEGER,
rateLimitPortEgrRate INTEGER,
rateLimitPortCommitRate INTEGER,
rateLimitPortPeakState EnabledStatus,
rateLimitPortEgrState EnabledStatus,
rateLimitPortCommitState EnabledStatus
}
rateLimitPortState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This item can enabled/disabled Commit Rate, Peak Rate, and Egress Rate at the same time.
It's meaningless while reading this entry."
::= { rateLimitPortEntry 1 }
rateLimitPortPeakRate OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Peak rate in Kbit/s. The range of FE port is between 1 and 100,000. For GE port, the range is between 1 and 1000,000."
::= { rateLimitPortEntry 2 }
rateLimitPortEgrRate OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Egress rate in Kbit/s. The range of FE port is between 1 and 100,000. For GE port, the range is between 1 and 1000,000."
::= { rateLimitPortEntry 3 }
rateLimitPortCommitRate OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Commit rate in Kbit/s. The range of FE port is between 0 and 100,000. For GE port, the range is between 0 and 1000,000."
::= { rateLimitPortEntry 4 }
rateLimitPortPeakState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Ingress peak rate limiting enabled/disabled on the port."
::= { rateLimitPortEntry 5 }
rateLimitPortEgrState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Egress rate limiting enabled/disabled on the port."
::= { rateLimitPortEntry 6 }
rateLimitPortCommitState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Ingress commit rate limiting enabled/disabled on the port."
::= { rateLimitPortEntry 7 }
-- brLimitSetup
brLimitSetup OBJECT IDENTIFIER ::= { mgs3712 3 }
brLimitState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Broadcast/multicast/DLF rate limiting enabled/disabled for the switch."
::= { brLimitSetup 1 }
-- brLimitPortTable
brLimitPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF BrLimitPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { brLimitSetup 2 }
brLimitPortEntry OBJECT-TYPE
SYNTAX BrLimitPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in brLimitPortTable."
INDEX { dot1dBasePort }
::= { brLimitPortTable 1 }
BrLimitPortEntry ::=
SEQUENCE {
brLimitPortBrState EnabledStatus,
brLimitPortBrRate INTEGER,
brLimitPortMcState EnabledStatus,
brLimitPortMcRate INTEGER,
brLimitPortDlfState EnabledStatus,
brLimitPortDlfRate INTEGER
}
brLimitPortBrState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Broadcast rate limiting enabled/disabled on the port."
::= { brLimitPortEntry 1 }
brLimitPortBrRate OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Allowed broadcast rate in pkts/s. For FE port,
the maximum value is 148800. For GE port, the maximum value is 262143."
::= { brLimitPortEntry 2 }
brLimitPortMcState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Multicast rate limiting enabled/disabled on the port."
::= { brLimitPortEntry 3 }
brLimitPortMcRate OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"AAllowed mullticast rate in pkts/s. For FE port,
the maximum value is 148800. For GE port, the maximum value is 262143."
::= { brLimitPortEntry 4 }
brLimitPortDlfState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Destination lookup failure frames rate limiting enabled/disabled on the port."
::= { brLimitPortEntry 5 }
brLimitPortDlfRate OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Allowed destination lookup failure frames rate in pkts/s.
For FE port, the maximum value is 148800. For GE port, the maximum value is 262143."
::= { brLimitPortEntry 6 }
-- portSecuritySetup
portSecuritySetup OBJECT IDENTIFIER ::= { mgs3712 4 }
portSecurityState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { portSecuritySetup 1 }
portSecurityPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF PortSecurityPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { portSecuritySetup 2 }
portSecurityPortEntry OBJECT-TYPE
SYNTAX PortSecurityPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in portSecurityPortTable."
INDEX { dot1dBasePort }
::= { portSecurityPortTable 1 }
PortSecurityPortEntry ::=
SEQUENCE {
portSecurityPortState EnabledStatus,
portSecurityPortLearnState EnabledStatus,
portSecurityPortCount INTEGER
}
portSecurityPortState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Port Security enabled/disabled on the port.
Active(1) means this port only accept frames from static MAC addresses that are configured for the port,
and dynamic MAC address frames up to the number specified by portSecurityPortCount object."
::= { portSecurityPortEntry 1 }
portSecurityPortLearnState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"MAC address learning enabled/disable on the port."
::= { portSecurityPortEntry 2 }
portSecurityPortCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Number of (dynamic) MAC addresses that may be learned on the port."
::= { portSecurityPortEntry 3 }
portSecurityMacFreeze OBJECT-TYPE
SYNTAX PortList
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This entry is used to execute MacFreeze action to port.
It's meaningless while reading this entry."
::= { portSecuritySetup 3 }
portSecurityVMLTable OBJECT-TYPE
SYNTAX SEQUENCE OF PortSecurityVMLEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { portSecuritySetup 4 }
portSecurityVMLEntry OBJECT-TYPE
SYNTAX PortSecurityVMLEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in portSecurityVMLTable."
INDEX { portSecurityVMLPort, portSecurityVMLVID }
::= { portSecurityVMLTable 1 }
PortSecurityVMLEntry ::=
SEQUENCE {
portSecurityVMLPort INTEGER,
portSecurityVMLVID INTEGER,
portSecurityVMLMacLimit INTEGER,
portSecurityVMLRowStatus RowStatus
}
portSecurityVMLPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The configured port number of VLAN MAC Limit."
::= { portSecurityVMLEntry 1 }
portSecurityVMLVID OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The configured VLAN number of VLAN MAC Limit."
::= { portSecurityVMLEntry 2 }
portSecurityVMLMacLimit OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The MAC limit of specific port and VLAN."
::= { portSecurityVMLEntry 3 }
portSecurityVMLRowStatus OBJECT-TYPE
SYNTAX RowStatus
ACCESS read-create
STATUS mandatory
DESCRIPTION
""
::= { portSecurityVMLEntry 4 }
-- vlanTrunkPortTable
vlanTrunkSetup OBJECT IDENTIFIER ::= { mgs3712 5 }
vlanTrunkPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF VlanTrunkPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { vlanTrunkSetup 1 }
vlanTrunkPortEntry OBJECT-TYPE
SYNTAX VlanTrunkPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in vlanTrunkPortTable."
INDEX { dot1dBasePort }
::= { vlanTrunkPortTable 1 }
VlanTrunkPortEntry ::=
SEQUENCE {
vlanTrunkPortState EnabledStatus
}
vlanTrunkPortState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"VlanTrunking enabled/disabled on the port.
Active(1) to allow frames belonging to unknown
VLAN groups to pass through the switch."
::= { vlanTrunkPortEntry 1 }
-- ctlProtTransSetup
ctlProtTransSetup OBJECT IDENTIFIER ::= { mgs3712 6 }
ctlProtTransState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Bridge control protocol transparency enabled/disabled for the switch"
::= { ctlProtTransSetup 1 }
-- ctlProtTransTunnelPortTable
ctlProtTransTunnelPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF CtlProtTransTunnelPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { ctlProtTransSetup 2 }
ctlProtTransTunnelPortEntry OBJECT-TYPE
SYNTAX CtlProtTransTunnelPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in ctlProtTransTunnelPortTable."
INDEX { dot1dBasePort }
::= { ctlProtTransTunnelPortTable 1 }
CtlProtTransTunnelPortEntry ::=
SEQUENCE {
ctlProtTransTunnelMode INTEGER
}
ctlProtTransTunnelMode OBJECT-TYPE
SYNTAX INTEGER{
peer(0),
tunnel(1),
discard(2),
network(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Bridge control protocol transparency mode for the port.
Modes: Peer(0), Tunnel(1), Discard(2), Network(3)"
::= { ctlProtTransTunnelPortEntry 1 }
---------------------------------------------------------------------
--
-- dot1x Setup
--
-- for AAA Service
-- 1. rename radius8021xSetup as dot1xSetup
-- 2. remove radiusLoginPrecedence (AAA Service: authentication login)
-- 3. remove radiusAnd8021xServer (AAA Service: radius server setup)
-- 4. DO NOT change oid for backward compatible
--
---------------------------------------------------------------------
-- dot1xSetup
dot1xSetup OBJECT IDENTIFIER ::= { mgs3712 7 }
-- portAuthState
portAuthState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"802.1x port authentication enabled/disabled for the switch."
::= { dot1xSetup 3 }
-- portAuthTable
portAuthTable OBJECT-TYPE
SYNTAX SEQUENCE OF PortAuthEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { dot1xSetup 4 }
portAuthEntry OBJECT-TYPE
SYNTAX PortAuthEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in portAuthTable."
INDEX { dot1dBasePort }
::= { portAuthTable 1 }
PortAuthEntry ::=
SEQUENCE {
portAuthEntryState EnabledStatus,
portReAuthEntryState EnabledStatus,
portReAuthEntryTimer INTEGER
}
portAuthEntryState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"802.1x port authentication enabled or disabled on the port."
::= { portAuthEntry 1 }
portReAuthEntryState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"802.1x port re-authentication enabled or disabled on the port."
::= { portAuthEntry 2 }
portReAuthEntryTimer OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Re-authentication timer in seconds."
::= { portAuthEntry 3 }
-- hardwareInfo
hwMonitorInfo OBJECT IDENTIFIER ::= { mgs3712 8 }
-- fabRpmTable
fanRpmTable OBJECT-TYPE
SYNTAX SEQUENCE OF FanRpmEntry
ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { hwMonitorInfo 1 }
fanRpmEntry OBJECT-TYPE
SYNTAX FanRpmEntry
ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in fanRpmTable."
INDEX { fanRpmIndex }
::= { fanRpmTable 1 }
FanRpmEntry ::=
SEQUENCE {
fanRpmIndex INTEGER,
fanRpmCurValue INTEGER,
fanRpmMaxValue INTEGER,
fanRpmMinValue INTEGER,
fanRpmLowThresh INTEGER,
fanRpmDescr DisplayString
}
fanRpmIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
"Index of FAN."
::= { fanRpmEntry 1 }
fanRpmCurValue OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
"Current speed in Revolutions Per Minute (RPM) on the fan."
::= { fanRpmEntry 2 }
fanRpmMaxValue OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
"Maximum speed measured in Revolutions Per Minute (RPM) on the fan."
::= { fanRpmEntry 3 }
fanRpmMinValue OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
"Minimum speed measured in Revolutions Per Minute (RPM) on the fan."
::= { fanRpmEntry 4 }
fanRpmLowThresh OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
"The minimum speed at which a normal fan should work."
::= { fanRpmEntry 5 }
fanRpmDescr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS current
DESCRIPTION
"'Normal' indicates that this fan is functioning above the minimum speed.
'Error' indicates that this fan is functioning below the minimum speed."
::= { fanRpmEntry 6 }
-- tempTable
tempTable OBJECT-TYPE
SYNTAX SEQUENCE OF TempEntry
ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { hwMonitorInfo 2 }
tempEntry OBJECT-TYPE
SYNTAX TempEntry
ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in tempTable."
INDEX { tempIndex }
::= { tempTable 1 }
TempEntry ::=
SEQUENCE {
tempIndex INTEGER,
tempCurValue INTEGER,
tempMaxValue INTEGER,
tempMinValue INTEGER,
tempHighThresh INTEGER,
tempDescr DisplayString
}
tempIndex OBJECT-TYPE
SYNTAX INTEGER {
mac (1),
cpu (2),
phy (3)
}
ACCESS read-only
STATUS current
DESCRIPTION
"Index of temperature unit. 1:MAC, 2:CPU, 3:PHY"
::= { tempEntry 1 }
tempCurValue OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
"The current temperature measured at this sensor."
::= { tempEntry 2 }
tempMaxValue OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
"The maximum temperature measured at this sensor."
::= { tempEntry 3 }
tempMinValue OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
"The minimum temperature measured at this sensor."
::= { tempEntry 4 }
tempHighThresh OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
"The upper temperature limit at this sensor."
::= { tempEntry 5 }
tempDescr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS current
DESCRIPTION
"'Normal' indicates temperatures below the threshold and 'Error' for those above."
::= { tempEntry 6 }
-- voltageTable
voltageTable OBJECT-TYPE
SYNTAX SEQUENCE OF VoltageEntry
ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { hwMonitorInfo 3 }
voltageEntry OBJECT-TYPE
SYNTAX VoltageEntry
ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in voltageTable."
INDEX { voltageIndex }
::= { voltageTable 1 }
VoltageEntry ::=
SEQUENCE {
voltageIndex INTEGER,
voltageCurValue INTEGER,
voltageMaxValue INTEGER,
voltageMinValue INTEGER,
voltageNominalValue INTEGER,
voltageLowThresh INTEGER,
voltageDescr DisplayString
}
voltageIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
"Index of voltage."
::= { voltageEntry 1 }
voltageCurValue OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
"The current voltage reading."
::= { voltageEntry 2 }
voltageMaxValue OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
"The maximum voltage measured at this point."
::= { voltageEntry 3 }
voltageMinValue OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
"The minimum voltage measured at this point."
::= { voltageEntry 4 }
voltageNominalValue OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
"The normal voltage at wchich the switch work."
::= { voltageEntry 5 }
voltageLowThresh OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
"The minimum voltage at which the switch should work."
::= { voltageEntry 6 }
voltageDescr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS current
DESCRIPTION
"'Normal' indicates that the voltage is within an acceptable operating range
at this point; otherwise 'Error' is displayed."
::= { voltageEntry 7 }
-- snmpSetup
snmpSetup OBJECT IDENTIFIER ::= { mgs3712 9 }
snmpGetCommunity OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { snmpSetup 1 }
snmpSetCommunity OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { snmpSetup 2 }
snmpTrapCommunity OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { snmpSetup 3 }
-- snmpTrapDestTable
snmpTrapDestTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnmpTrapDestEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { snmpSetup 4 }
snmpTrapDestEntry OBJECT-TYPE
SYNTAX SnmpTrapDestEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in snmpTrapDestTable."
INDEX { snmpTrapDestIP }
::= { snmpTrapDestTable 1 }
SnmpTrapDestEntry ::=
SEQUENCE {
snmpTrapDestIP IpAddress,
snmpTrapDestRowStatus RowStatus,
snmpTrapDestPort INTEGER,
snmpTrapVersion INTEGER,
snmpTrapUserName DisplayString
}
snmpTrapDestIP OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"IP address of trap destination."
::= { snmpTrapDestEntry 1 }
snmpTrapDestRowStatus OBJECT-TYPE
SYNTAX RowStatus
ACCESS read-create
STATUS mandatory
DESCRIPTION
""
::= { snmpTrapDestEntry 2 }
snmpTrapDestPort OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS mandatory
DESCRIPTION
"The UDP port of the trap destination."
::= { snmpTrapDestEntry 3 }
snmpTrapVersion OBJECT-TYPE
SYNTAX INTEGER {
v1(0),
v2c(1),
v3(2)
}
MAX-ACCESS read-write
STATUS mandatory
DESCRIPTION
"The SNMP protocol version to send traps."
::= { snmpTrapDestEntry 4 }
snmpTrapUserName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS mandatory
DESCRIPTION
"The user name for sending SNMPv3 traps."
::= { snmpTrapDestEntry 5 }
--snmpVersion
snmpVersion OBJECT-TYPE
SYNTAX INTEGER {
v2c(0),
v3(1),
v3v2c(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The SNMP version to be used. v3v2c means that the manager
can get/set by SNMPv3 and can get by SNMPv2c."
::= { snmpSetup 5 }
-- snmpUserTable
snmpUserTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnmpUserEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains SNMPv3 user information."
::= { snmpSetup 6 }
snmpUserEntry OBJECT-TYPE
SYNTAX SnmpUserEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of snmpUserTable."
INDEX { snmpUserName }
::= { snmpUserTable 1 }
SnmpUserEntry ::=
SEQUENCE {
snmpUserName DisplayString,
snmpUserSecurityLevel INTEGER,
snmpUserAuthProtocol INTEGER,
snmpUserPrivProtocol INTEGER
}
snmpUserName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The user name."
::= { snmpUserEntry 1 }
snmpUserSecurityLevel OBJECT-TYPE
SYNTAX INTEGER {
noAuthNoPriv(0),
authNoPriv(1),
authPriv(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The level of security at which SNMP messages can be sent or
with which operations are being processed."
::= { snmpUserEntry 2 }
snmpUserAuthProtocol OBJECT-TYPE
SYNTAX INTEGER {
md5(0),
sha(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The type of authentication protocol to be used."
::= { snmpUserEntry 3 }
snmpUserPrivProtocol OBJECT-TYPE
SYNTAX INTEGER {
des(0),
aes(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The type of privacy protocol to be used."
::= { snmpUserEntry 4 }
-- snmpTrapGroupTable
snmpTrapGroupTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnmpTrapGroupEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { snmpSetup 7 }
snmpTrapGroupEntry OBJECT-TYPE
SYNTAX SnmpTrapGroupEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in snmpTrapGroupTable."
INDEX { snmpTrapDestIP }
::= { snmpTrapGroupTable 1 }
SnmpTrapGroupEntry ::=
SEQUENCE {
snmpTrapSystemGroup BITS,
snmpTrapInterfaceGroup BITS,
snmpTrapAAAGroup BITS,
snmpTrapIPGroup BITS,
snmpTrapSwitchGroup BITS
}
snmpTrapSystemGroup OBJECT-TYPE
SYNTAX BITS {
coldStart(0),
warmStart(1),
fanSpeed(2),
temperature(3),
voltage(4),
reset (5),
timeSync (6),
intrusionlock(7),
loopGuard(13),
externalalarm(10)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { snmpTrapGroupEntry 1 }
snmpTrapInterfaceGroup OBJECT-TYPE
SYNTAX BITS {
linkup(0),
linkdown(1),
autonegotiation(2),
lldp(3),
transceiver-ddm(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { snmpTrapGroupEntry 2 }
snmpTrapAAAGroup OBJECT-TYPE
SYNTAX BITS {
authentication(0),
accounting(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { snmpTrapGroupEntry 3 }
snmpTrapIPGroup OBJECT-TYPE
SYNTAX BITS {
ping(0),
traceroute(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { snmpTrapGroupEntry 4 }
snmpTrapSwitchGroup OBJECT-TYPE
SYNTAX BITS {
stp(0),
mactable(1),
rmon(2),
cfm(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { snmpTrapGroupEntry 5 }
-- dateTimeSetup
dateTimeSetup OBJECT IDENTIFIER ::= { mgs3712 10 }
dateTimeServerType OBJECT-TYPE
SYNTAX INTEGER {
none(1),
daytime(2),
time(3),
ntp(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The time service protocol."
::= { dateTimeSetup 1 }
dateTimeServerIP OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IP address of time server."
::= { dateTimeSetup 2 }
dateTimeZone OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The time difference between UTC. Ex: +01"
::= { dateTimeSetup 3 }
dateTimeNewDateYear OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The new date in year."
::= { dateTimeSetup 4 }
dateTimeNewDateMonth OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The new date in month."
::= { dateTimeSetup 5 }
dateTimeNewDateDay OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The new date in day."
::= { dateTimeSetup 6 }
dateTimeNewTimeHour OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The new time in hour."
::= { dateTimeSetup 7 }
dateTimeNewTimeMinute OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The new time in minute."
::= { dateTimeSetup 8 }
dateTimeNewTimeSecond OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The new time in second."
::= { dateTimeSetup 9 }
-- dateTimeDaylightSavingTimeSetup OBJECT-TYPE
dateTimeDaylightSavingTimeSetup OBJECT IDENTIFIER ::= { dateTimeSetup 10 }
daylightSavingTimeState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Daylight saving time service enabled/disabled for the switch."
::= { dateTimeDaylightSavingTimeSetup 1 }
daylightSavingTimeStartDateWeek OBJECT-TYPE
SYNTAX INTEGER {
first(1),
second(2),
third(3),
fourth(4),
last(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Daylight saving time service start week."
::= { dateTimeDaylightSavingTimeSetup 2 }
daylightSavingTimeStartDateDay OBJECT-TYPE
SYNTAX INTEGER {
sunday(0),
monday(1),
tuesday(2),
wednesday(3),
thursday(4),
friday(5),
saturday(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Daylight saving time service start day."
::= { dateTimeDaylightSavingTimeSetup 3 }
daylightSavingTimeStartDateMonth OBJECT-TYPE
SYNTAX INTEGER {
january(1),
february(2),
march(3),
april(4),
may(5),
june(6),
july(7),
august(8),
september(9),
october(10),
november(11),
december(12)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Daylight saving time service start month."
::= { dateTimeDaylightSavingTimeSetup 4 }
daylightSavingTimeStartDateHour OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Daylight saving time service start time."
::= { dateTimeDaylightSavingTimeSetup 5 }
daylightSavingTimeEndDateWeek OBJECT-TYPE
SYNTAX INTEGER {
first(1),
second(2),
third(3),
fourth(4),
last(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Daylight saving time service end week."
::= { dateTimeDaylightSavingTimeSetup 6 }
daylightSavingTimeEndDateDay OBJECT-TYPE
SYNTAX INTEGER {
sunday(0),
monday(1),
tuesday(2),
wednesday(3),
thursday(4),
friday(5),
saturday(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Daylight saving time service end day."
::= { dateTimeDaylightSavingTimeSetup 7 }
daylightSavingTimeEndDateMonth OBJECT-TYPE
SYNTAX INTEGER {
january(1),
february(2),
march(3),
april(4),
may(5),
june(6),
july(7),
august(8),
september(9),
october(10),
november(11),
december(12)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Daylight saving time service end month."
::= { dateTimeDaylightSavingTimeSetup 8 }
daylightSavingTimeEndDateHour OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Daylight saving time service end time."
::= { dateTimeDaylightSavingTimeSetup 9 }
-- sysMgmt
sysMgmt OBJECT IDENTIFIER ::= { mgs3712 11 }
sysMgmtConfigSave OBJECT-TYPE
SYNTAX INTEGER {
config_1(1),
config_2(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"If setting value is given, the variable write index will be set and running-config will be written to the assigned configuration file.
If not, running-config will be written to the booting one."
::= { sysMgmt 1 }
sysMgmtBootupConfig OBJECT-TYPE
SYNTAX INTEGER {
config_1(1),
config_2(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The setting value (read index) will be written into non-volatile memory.
While rebooting, the variable write index is equal to read index initially.
You can change the value of write index by CLI / MIB."
::= { sysMgmt 2 }
sysMgmtReboot OBJECT-TYPE
SYNTAX INTEGER {
nothing(0),
reboot(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Reboot switch from SNMP. 1:Reboot, 0:Nothing"
::= { sysMgmt 3 }
sysMgmtDefaultConfig OBJECT-TYPE
SYNTAX INTEGER {
nothing(0),
reset_to_default(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Erase running config and reset to default."
::= { sysMgmt 4 }
sysMgmtLastActionStatus OBJECT-TYPE
SYNTAX INTEGER {
none(0),
success(1),
fail(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Display status of last mgmt action."
::= { sysMgmt 5 }
sysMgmtSystemStatus OBJECT-TYPE
SYNTAX BITS {
sysAlarmDetected(0),
sysTemperatureError(1),
sysFanRPMError(2),
sysVoltageRangeError(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable indicates the status of the system.
The sysMgmtAlarmStatus is a bit map represented
a sum, therefore, it can represent multiple defects
simultaneously. The sysNoDefect should be set if and only if
no other flag is set.
The various bit positions are:
0 sysAlarmDetected
1 sysTemperatureError
2 sysFanRPMError
3 sysVoltageRangeError"
::= { sysMgmt 6 }
sysMgmtCPUUsage OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Show device CPU load in %, it's the snapshot of CPU load when
getting the values."
::= { sysMgmt 7 }
sysMgmtBootupImage OBJECT-TYPE
SYNTAX INTEGER {
image_1(1),
image_2(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The setting value (read index) will be written into non-volatile memory.
When rebooting, the selected image will be used.
You can change the value of write index by CLI / MIB."
::= { sysMgmt 8 }
sysMgmtCounterReset OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Reset all port counters."
::= { sysMgmt 9 }
-- Tftp service
sysMgmtTftpServiceSetup OBJECT IDENTIFIER ::= { sysMgmt 10 }
sysMgmtTftpServerIp OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
" IP address of TFTP server"
::= { sysMgmtTftpServiceSetup 1 }
sysMgmtTftpRemoteFileName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The file name that you want to backup to or restore from TFTP server"
::= { sysMgmtTftpServiceSetup 2 }
sysMgmtTftpConfigIndex OBJECT-TYPE
SYNTAX INTEGER {
config_1(1),
config_2(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Index of system configuration which you want to restore."
::= { sysMgmtTftpServiceSetup 3 }
sysMgmtTftpAction OBJECT-TYPE
SYNTAX INTEGER {
none(0),
backup_config(1),
restore_config(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Action of tftp service. 1: Backup running-config to tftp server, 2: Restore config from tftp server."
::= { sysMgmtTftpServiceSetup 4 }
sysMgmtTftpActionStatus OBJECT-TYPE
SYNTAX INTEGER {
none(0),
success(1),
fail(2),
under-action(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Display status of mgmt action."
::= { sysMgmtTftpServiceSetup 5 }
-- layer2Setup
layer2Setup OBJECT IDENTIFIER ::= { mgs3712 12 }
vlanTypeSetup OBJECT-TYPE
SYNTAX INTEGER {
dot1Q(1),
port_based(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { layer2Setup 1 }
igmpSnoopingStateSetup OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { layer2Setup 2 }
tagVlanPortIsolationState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { layer2Setup 3 }
stpState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { layer2Setup 4 }
igmpFilteringStateSetup OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { layer2Setup 6 }
unknownMulticastFrameForwarding OBJECT-TYPE
SYNTAX INTEGER {
flooding(1),
drop(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { layer2Setup 7 }
multicastGrpHostTimeout OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specify host timeout for all multicast groups when the specific port is in auto mode."
::= { layer2Setup 8 }
reservedMulticastFrameForwarding OBJECT-TYPE
SYNTAX INTEGER {
flooding(1),
drop(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { layer2Setup 10 }
igmpsnp8021pPriority OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Set the 802.1p priority of control messages for igmp-snooping(0~8, 8-No Change)"
::= { layer2Setup 11 }
igmpsnpVlanMode OBJECT-TYPE
SYNTAX INTEGER {
auto(1),
fixed(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { layer2Setup 12 }
stpMode OBJECT-TYPE
SYNTAX INTEGER {
rstp(1),
mrstp(2),
mstp (3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { layer2Setup 13 }
-- igmpsnpVlanTable
igmpsnpVlanTable OBJECT-TYPE
SYNTAX SEQUENCE OF IgmpsnpVlanEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { layer2Setup 14 }
igmpsnpVlanEntry OBJECT-TYPE
SYNTAX IgmpsnpVlanEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in IgmpsnpVlanTable."
INDEX { igmpsnpVid }
::= { igmpsnpVlanTable 1 }
IgmpsnpVlanEntry ::=
SEQUENCE {
igmpsnpVid INTEGER,
igmpsnpVlanName DisplayString,
igmpsnpVlanRowStatus RowStatus
}
igmpsnpVid OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { igmpsnpVlanEntry 1 }
igmpsnpVlanName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { igmpsnpVlanEntry 2 }
igmpsnpVlanRowStatus OBJECT-TYPE
SYNTAX RowStatus
ACCESS read-create
STATUS mandatory
DESCRIPTION
""
::= { igmpsnpVlanEntry 3 }
igmpsnpQuerierMode OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { layer2Setup 15 }
ethernetCfmStateSetup OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { layer2Setup 16 }
-- ipSetup
ipSetup OBJECT IDENTIFIER ::= { mgs3712 13 }
dnsIpAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { ipSetup 1 }
defaultMgmt OBJECT-TYPE
SYNTAX INTEGER {
in_band(0),
out_of_band(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { ipSetup 2 }
inbandIpSetup OBJECT IDENTIFIER ::= { ipSetup 3 }
inbandIpType OBJECT-TYPE
SYNTAX INTEGER {
dhcp_client(0),
static_ip(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { inbandIpSetup 1 }
inbandVid OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { inbandIpSetup 2 }
inbandStaticIp OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { inbandIpSetup 3 }
inbandStaticSubnetMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { inbandIpSetup 4 }
inbandStaticGateway OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { inbandIpSetup 5 }
outOfBandIpSetup OBJECT IDENTIFIER ::= { ipSetup 4 }
outOfBandIp OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { outOfBandIpSetup 1 }
outOfBandSubnetMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { outOfBandIpSetup 2 }
outOfBandGateway OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { outOfBandIpSetup 3 }
maxNumOfInbandIp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { ipSetup 5 }
-- inbandIpTable
inbandIpTable OBJECT-TYPE
SYNTAX SEQUENCE OF InbandIpEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { ipSetup 6 }
inbandIpEntry OBJECT-TYPE
SYNTAX InbandIpEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in inbandIpTable."
INDEX { inbandEntryIp, inbandEntryVid }
::= { inbandIpTable 1 }
InbandIpEntry ::=
SEQUENCE {
inbandEntryIp IpAddress,
inbandEntrySubnetMask IpAddress,
inbandEntryGateway IpAddress,
inbandEntryVid INTEGER,
inbandEntryRowStatus RowStatus
}
inbandEntryIp OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { inbandIpEntry 1 }
inbandEntrySubnetMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { inbandIpEntry 2 }
inbandEntryGateway OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { inbandIpEntry 3 }
inbandEntryVid OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { inbandIpEntry 4 }
inbandEntryRowStatus OBJECT-TYPE
SYNTAX RowStatus
ACCESS read-create
STATUS mandatory
DESCRIPTION
""
::= { inbandIpEntry 6 }
-- filterSetup
filterSetup OBJECT IDENTIFIER ::= { mgs3712 14 }
-- filterTable
filterTable OBJECT-TYPE
SYNTAX SEQUENCE OF FilterEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { filterSetup 1 }
filterEntry OBJECT-TYPE
SYNTAX FilterEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in filterTable."
INDEX { filterMacAddr, filterVid }
::= { filterTable 1 }
FilterEntry ::=
SEQUENCE {
filterName DisplayString,
filterActionState INTEGER,
filterMacAddr MacAddress,
filterVid INTEGER,
filterRowStatus RowStatus
}
filterName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { filterEntry 1 }
filterActionState OBJECT-TYPE
SYNTAX INTEGER {
discard_source(1),
discard_destination(2),
both(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { filterEntry 2 }
filterMacAddr OBJECT-TYPE
SYNTAX MacAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { filterEntry 3 }
filterVid OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { filterEntry 4 }
filterRowStatus OBJECT-TYPE
SYNTAX RowStatus
ACCESS read-create
STATUS mandatory
DESCRIPTION
""
::= { filterEntry 5 }
-- mirrorSetup
mirrorSetup OBJECT IDENTIFIER ::= { mgs3712 15 }
-- mirrorState
mirrorState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { mirrorSetup 1 }
mirrorMonitorPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { mirrorSetup 2 }
-- mirrorTable
mirrorTable OBJECT-TYPE
SYNTAX SEQUENCE OF MirrorEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { mirrorSetup 3 }
mirrorEntry OBJECT-TYPE
SYNTAX MirrorEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in mirrorTable."
INDEX { dot1dBasePort }
::= { mirrorTable 1 }
MirrorEntry ::=
SEQUENCE {
mirrorMirroredState EnabledStatus,
mirrorDirection INTEGER
}
mirrorMirroredState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { mirrorEntry 1 }
mirrorDirection OBJECT-TYPE
SYNTAX INTEGER {
ingress(0),
egress(1),
both(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { mirrorEntry 2 }
-- aggrSetup
aggrSetup OBJECT IDENTIFIER ::= { mgs3712 16 }
aggrState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { aggrSetup 1 }
aggrSystemPriority OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { aggrSetup 2 }
-- aggrGroupTable
aggrGroupTable OBJECT-TYPE
SYNTAX SEQUENCE OF AggrGroupEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { aggrSetup 3 }
aggrGroupEntry OBJECT-TYPE
SYNTAX AggrGroupEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in aggrGroupTable."
INDEX { aggrGroupIndex }
::= { aggrGroupTable 1 }
AggrGroupEntry ::=
SEQUENCE {
aggrGroupIndex INTEGER,
aggrGroupState EnabledStatus,
aggrGroupDynamicState EnabledStatus,
aggrGroupCriteria INTEGER
}
aggrGroupIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { aggrGroupEntry 1 }
aggrGroupState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { aggrGroupEntry 2 }
aggrGroupDynamicState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { aggrGroupEntry 3 }
aggrGroupCriteria OBJECT-TYPE
SYNTAX INTEGER {
src-mac (1),
dst-mac (2),
src-dst-mac (3),
src-ip (4),
dst-ip (5),
src-dst-ip (6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { aggrGroupEntry 4 }
-- aggrPortTable
aggrPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF AggrPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { aggrSetup 4 }
aggrPortEntry OBJECT-TYPE
SYNTAX AggrPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in aggrPortTable."
INDEX { dot1dBasePort }
::= { aggrPortTable 1 }
AggrPortEntry ::=
SEQUENCE {
aggrPortGroup INTEGER,
aggrPortDynamicStateTimeout INTEGER
}
aggrPortGroup OBJECT-TYPE
SYNTAX INTEGER {
none(0),
t1(1),
t2(2),
t3(3),
t4(4),
t5(5),
t6(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { aggrPortEntry 1 }
aggrPortDynamicStateTimeout OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { aggrPortEntry 2 }
-- accessCtlSetup
accessCtlSetup OBJECT IDENTIFIER ::= { mgs3712 17 }
-- accessCtlTable
accessCtlTable OBJECT-TYPE
SYNTAX SEQUENCE OF AccessCtlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { accessCtlSetup 1 }
accessCtlEntry OBJECT-TYPE
SYNTAX AccessCtlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in accessCtlTable."
INDEX { accessCtlService }
::= { accessCtlTable 1 }
AccessCtlEntry ::=
SEQUENCE {
accessCtlService INTEGER,
accessCtlEnable EnabledStatus,
accessCtlServicePort INTEGER,
accessCtlTimeout INTEGER
}
accessCtlService OBJECT-TYPE
SYNTAX INTEGER {
telnet(1),
ssh(2),
ftp(3),
http(4),
https(5),
icmp(6),
snmp(7)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { accessCtlEntry 1 }
accessCtlEnable OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { accessCtlEntry 2 }
accessCtlServicePort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { accessCtlEntry 3 }
accessCtlTimeout OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { accessCtlEntry 4 }
-- securedClientTable
securedClientTable OBJECT-TYPE
SYNTAX SEQUENCE OF SecuredClientEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { accessCtlSetup 2 }
securedClientEntry OBJECT-TYPE
SYNTAX SecuredClientEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in securedClientTable."
INDEX { securedClientIndex }
::= { securedClientTable 1 }
SecuredClientEntry ::=
SEQUENCE {
securedClientIndex INTEGER,
securedClientEnable EnabledStatus,
securedClientStartIp IpAddress,
securedClientEndIp IpAddress,
securedClientService BITS
}
securedClientIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { securedClientEntry 1 }
securedClientEnable OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { securedClientEntry 2 }
securedClientStartIp OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { securedClientEntry 3 }
securedClientEndIp OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { securedClientEntry 4 }
securedClientService OBJECT-TYPE
SYNTAX BITS {
telnet(0),
ftp(1),
http(2),
icmp(3),
snmp(4),
ssh(5),
https(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { securedClientEntry 5 }
-- queuingMethodSetup
queuingMethodSetup OBJECT IDENTIFIER ::= { mgs3712 18 }
-- portQueuingMethodTable
portQueuingMethodTable OBJECT-TYPE
SYNTAX SEQUENCE OF PortQueuingMethodEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { queuingMethodSetup 1 }
portQueuingMethodEntry OBJECT-TYPE
SYNTAX PortQueuingMethodEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in portQueuingMethodTable."
INDEX { dot1dBasePort, portQueuingMethodQueue }
::= { portQueuingMethodTable 1 }
PortQueuingMethodEntry ::=
SEQUENCE {
portQueuingMethodQueue INTEGER,
portQueuingMethodWeight INTEGER,
portQueuingMethodMode INTEGER
}
portQueuingMethodQueue OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"0...7"
::= { portQueuingMethodEntry 1 }
portQueuingMethodWeight OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"0...15"
::= { portQueuingMethodEntry 2 }
portQueuingMethodMode OBJECT-TYPE
SYNTAX INTEGER {
strictly_priority(0),
weighted_round_robin(1),
weighted_fair_scheduling(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { portQueuingMethodEntry 3 }
-- portQueuingMethodHybridSpqTable
portQueuingMethodHybridSpqTable OBJECT-TYPE
SYNTAX SEQUENCE OF PortQueuingMethodHybridSpqEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { queuingMethodSetup 2 }
portQueuingMethodHybridSpqEntry OBJECT-TYPE
SYNTAX PortQueuingMethodHybridSpqEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in portQueuingMethodHybridSpqTable."
INDEX { dot1dBasePort }
::= {portQueuingMethodHybridSpqTable 1}
PortQueuingMethodHybridSpqEntry ::=
SEQUENCE {
portQueuingMethodHybridSpq INTEGER
}
portQueuingMethodHybridSpq OBJECT-TYPE
SYNTAX INTEGER {
none(0),
q0(1),
q1(2),
q2(3),
q3(4),
q4(5),
q5(6),
q6(7),
q7(8)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specify the queues of SPQ while other queueing method working. The selected Qx and higher serve as SPQ, and the rest of others serve as configured queuing methods."
::= { portQueuingMethodHybridSpqEntry 1 }
-- dhcpSetup
dhcpSetup OBJECT IDENTIFIER ::= { mgs3712 19 }
globalDhcpRelay OBJECT IDENTIFIER ::= { dhcpSetup 1 }
globalDhcpRelayEnable OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { globalDhcpRelay 1 }
globalDhcpRelayOption82Enable OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { globalDhcpRelay 2 }
globalDhcpRelayInfoEnable OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { globalDhcpRelay 3 }
globalDhcpRelayInfoData OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { globalDhcpRelay 4 }
-- globalDhcpRelayRemoteServer
maxNumberOfGlobalDhcpRelayRemoteServer OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { globalDhcpRelay 5 }
-- globalDhcpRelayRemoteServerTable
globalDhcpRelayRemoteServerTable OBJECT-TYPE
SYNTAX SEQUENCE OF GlobalDhcpRelayRemoteServerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { globalDhcpRelay 6 }
globalDhcpRelayRemoteServerEntry OBJECT-TYPE
SYNTAX GlobalDhcpRelayRemoteServerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in globalDhcpRelayRemoteServerTable."
INDEX { globalDhcpRelayRemoteServerIp }
::= { globalDhcpRelayRemoteServerTable 1 }
GlobalDhcpRelayRemoteServerEntry ::=
SEQUENCE {
globalDhcpRelayRemoteServerIp IpAddress,
globalDhcpRelayRemoteServerRowStatus RowStatus
}
globalDhcpRelayRemoteServerIp OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { globalDhcpRelayRemoteServerEntry 1 }
globalDhcpRelayRemoteServerRowStatus OBJECT-TYPE
SYNTAX RowStatus
ACCESS read-create
STATUS mandatory
DESCRIPTION
""
::= { globalDhcpRelayRemoteServerEntry 2 }
--
dhcpRelay OBJECT IDENTIFIER ::= { dhcpSetup 3 }
dhcpRelayInfoData OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { dhcpRelay 1 }
maxNumberOfDhcpRelay OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The maximum number of DHCP relay entries that can be created.
A value of 0 for this object implies that there exists settings for
global DHCP relay."
::= { dhcpRelay 2 }
maxNumberOfDhcpRelayRemoteServer OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { dhcpRelay 3 }
-- dhcpRelayRemoteServerTable
dhcpRelayRemoteServerTable OBJECT-TYPE
SYNTAX SEQUENCE OF DhcpRelayRemoteServerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { dhcpRelay 4 }
dhcpRelayRemoteServerEntry OBJECT-TYPE
SYNTAX DhcpRelayRemoteServerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in dhcpRelayRemoteServerTable."
INDEX { dhcpRelayVid, dhcpRelayRemoteServerIp }
::= { dhcpRelayRemoteServerTable 1 }
DhcpRelayRemoteServerEntry ::=
SEQUENCE {
dhcpRelayVid INTEGER,
dhcpRelayRemoteServerIp IpAddress,
dhcpRelayRemoteServerRowStatus RowStatus
}
dhcpRelayVid OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { dhcpRelayRemoteServerEntry 1 }
dhcpRelayRemoteServerIp OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { dhcpRelayRemoteServerEntry 2 }
dhcpRelayRemoteServerRowStatus OBJECT-TYPE
SYNTAX RowStatus
ACCESS read-create
STATUS mandatory
DESCRIPTION
""
::= { dhcpRelayRemoteServerEntry 3 }
-- dhcpRelayTable
dhcpRelayTable OBJECT-TYPE
SYNTAX SEQUENCE OF DhcpRelayEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { dhcpRelay 5 }
dhcpRelayEntry OBJECT-TYPE
SYNTAX DhcpRelayEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in dhcpRelayTable."
INDEX { dhcpRelayVid }
::= { dhcpRelayTable 1 }
DhcpRelayEntry ::=
SEQUENCE {
dhcpRelayOption82Enable EnabledStatus,
dhcpRelayInfoEnable EnabledStatus
}
dhcpRelayOption82Enable OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { dhcpRelayEntry 1 }
dhcpRelayInfoEnable OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { dhcpRelayEntry 2 }
-- staticRouteSetup
staticRouteSetup OBJECT IDENTIFIER ::= { mgs3712 20 }
maxNumberOfStaticRoutes OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { staticRouteSetup 1 }
-- staticRouteTable
staticRouteTable OBJECT-TYPE
SYNTAX SEQUENCE OF StaticRouteEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { staticRouteSetup 2 }
staticRouteEntry OBJECT-TYPE
SYNTAX StaticRouteEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in staticRouteTable."
INDEX { staticRouteIp, staticRouteMask }
::= { staticRouteTable 1 }
StaticRouteEntry ::=
SEQUENCE {
staticRouteName DisplayString,
staticRouteIp IpAddress,
staticRouteMask IpAddress,
staticRouteGateway IpAddress,
staticRouteMetric INTEGER,
staticRouteRowStatus RowStatus
}
staticRouteName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { staticRouteEntry 1 }
staticRouteIp OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { staticRouteEntry 2 }
staticRouteMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { staticRouteEntry 3 }
staticRouteGateway OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { staticRouteEntry 4 }
staticRouteMetric OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { staticRouteEntry 5 }
staticRouteRowStatus OBJECT-TYPE
SYNTAX RowStatus
ACCESS read-create
STATUS mandatory
DESCRIPTION
""
::= { staticRouteEntry 6 }
-- arpInfo
arpInfo OBJECT IDENTIFIER ::= { mgs3712 21 }
-- arpTable
arpTable OBJECT-TYPE
SYNTAX SEQUENCE OF ArpEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { arpInfo 1 }
arpEntry OBJECT-TYPE
SYNTAX ArpEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in arpTable."
INDEX { arpIpAddr, arpMacVid }
::= { arpTable 1 }
ArpEntry ::=
SEQUENCE {
arpIndex INTEGER,
arpIpAddr IpAddress,
arpMacAddr MacAddress,
arpMacVid INTEGER,
arpType INTEGER
}
arpIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { arpEntry 1 }
arpIpAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { arpEntry 2 }
arpMacAddr OBJECT-TYPE
SYNTAX MacAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { arpEntry 3 }
arpMacVid OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { arpEntry 4 }
arpType OBJECT-TYPE
SYNTAX INTEGER {
static(1),
dynamic(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"1-static, 2-dynamic"
::= { arpEntry 5 }
-- portOpModeSetup
portOpModeSetup OBJECT IDENTIFIER ::= { mgs3712 22 }
-- portOpModePortTable
portOpModePortTable OBJECT-TYPE
SYNTAX SEQUENCE OF PortOpModePortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { portOpModeSetup 1 }
portOpModePortEntry OBJECT-TYPE
SYNTAX PortOpModePortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in portOpModePortTable."
INDEX { dot1dBasePort }
::= { portOpModePortTable 1 }
PortOpModePortEntry ::=
SEQUENCE {
portOpModePortSpeedDuplex INTEGER,
portOpModePortFlowCntl INTEGER,
portOpModePortName OCTET STRING,
portOpModePortModuleType INTEGER,
portOpModePortLinkUpType INTEGER,
portOpModePortIntrusionLock EnabledStatus,
portOpModePortLBTestStatus INTEGER,
portOpModePortCounterReset INTEGER
}
portOpModePortSpeedDuplex OBJECT-TYPE
SYNTAX INTEGER {
auto(0),
speed_10_half(1),
speed_10_full(2),
speed_100_half(3),
speed_100_full(4),
speed_1000_full(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { portOpModePortEntry 1 }
portOpModePortFlowCntl OBJECT-TYPE
SYNTAX INTEGER {
off(0),
on(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { portOpModePortEntry 2 }
portOpModePortName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..64))
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { portOpModePortEntry 3 }
portOpModePortModuleType OBJECT-TYPE
SYNTAX INTEGER {
fast_ethernet_10_100(0),
gigabit_ethernet_100_1000(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { portOpModePortEntry 4 }
portOpModePortLinkUpType OBJECT-TYPE
SYNTAX INTEGER {
down(0),
copper(1),
fiber(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { portOpModePortEntry 5 }
portOpModePortIntrusionLock OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { portOpModePortEntry 6 }
portOpModePortLBTestStatus OBJECT-TYPE
SYNTAX INTEGER {
none(0),
under_testing(1),
success(2),
fail(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This entry display latest loopback test status of port while performing loopback test."
::= { portOpModePortEntry 7 }
portOpModePortCounterReset OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This entry resets port counter."
::= { portOpModePortEntry 8 }
-- portBasedVlanSetup
portBasedVlanSetup OBJECT IDENTIFIER ::= { mgs3712 23 }
-- portBasedVlanPortListTable
portBasedVlanPortListTable OBJECT-TYPE
SYNTAX SEQUENCE OF PortBasedVlanPortListEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { portBasedVlanSetup 1 }
portBasedVlanPortListEntry OBJECT-TYPE
SYNTAX PortBasedVlanPortListEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in portBasedVlanPortListTable."
INDEX { dot1dBasePort }
::= { portBasedVlanPortListTable 1 }
PortBasedVlanPortListEntry ::=
SEQUENCE {
portBasedVlanPortListMembers OCTET STRING
}
portBasedVlanPortListMembers OBJECT-TYPE
SYNTAX PortList
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { portBasedVlanPortListEntry 1 }
--fault MIB
faultMIB MODULE-IDENTITY
LAST-UPDATED "200411031200Z" -- YYYY/MM/DD, HH/MM
ORGANIZATION "ZyXEL"
CONTACT-INFO ""
DESCRIPTION
"Fault event table definitions"
::= { mgs3712 24 }
-- **************************************************************************
-- Local Textual Conventions
-- **************************************************************************
UtcTimeStamp ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Universal Time Coordinated as a 32-bit value that designates
the number of seconds since Jan 1, 1970 12:00AM."
SYNTAX Unsigned32
EventIdNumber ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This textual convention describes the index that uniquely
identifies a fault event type in the entire system. Every fault
event type, e.g. link down, has a unique EventIdNumber."
SYNTAX Integer32
EventSeverity ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This textual convention describes the severity of a fault event.
The decreasing order of severity is shown in the textual
convention."
SYNTAX INTEGER{
critical (1),
major (2),
minor (3),
informational (4)
}
EventServiceAffective ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This textual convention indicates whether an event is immediately
service affecting or not."
SYNTAX INTEGER{
noServiceAffected (1),
serviceAffected (2)
}
InstanceType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This textual convention describes the type of an instanceId
associated with each event and by that means specifies how
the instanceId variable should be intepreted.
Various instanceId types are specified below to enable fault
monitoring for different kind of devices from fixed
configuration pizza boxes to multi chassis nodes. All
instanceId types may not need to be used in every device
type.
Note also that instanceId semantics are element type dependent
(e.g. different kind of interface naming conventions may be used)
and thus instanceId usage may vary from element to element.
=========================================================================
Type Description Example form
of InstanceId
=========================================================================
unknown (1) unknown type - Irrelevant-
-------------------------------------------------------------------------
node (2) Associated with events originating from 1
the node. Used for general events that (Node number)
can not be associated with any specific
block. InstanceId value 1 is used for
single node equipment.
-------------------------------------------------------------------------
shelf (3) Associated with events originating from 1
the shelf. In the case of fixed (shelf number)
configuration devices this type is used
for events that are associated with the
physical enclosure, e.g. faults related
to fan etc. InstanceId value 1 is used
for single self equipment.
-------------------------------------------------------------------------
line (4) Associated with events originating from
physical interfaces or associated
components such as line cards.
InstanceId usage examples for faults
originating from:
- Physical port: Simply port number, e.g. .......1
-------------------------------------------------------------------------
switch (5) Associated with events originating from 1
from a switch chip or a switch card. (switch number)
For single switch equipment InstanceId
value 1 is used, for multi swich nodes
InstanceId semantics if for further
study.
-------------------------------------------------------------------------
lsp (6) Associated with events originating from 1
a particular lsp. (lsp index)
NOTE: In this case the InstanceName
contains the lsp name and InstanceId
contains lsp index.
-------------------------------------------------------------------------
l2Interface(7) Associated with events originating from - TBD -
a particular layer 2 interface. Used for
layer 2 related events such as L2 control
protocol faults. InstanceId semantics is
for further study.
-------------------------------------------------------------------------
l3Interface(8) Associated with events originating from - TBD -
a particular layer 3 interface. Used for
layer 3 related events such as L3 control
protocol faults. InstanceId semantics is
for further study.
-------------------------------------------------------------------------
rowIndex (9) Associated with events reporting about a
'logical' or conceptual table that consists
of rows. The Instance Id is the index/key
for a row in the table. The format of the
Instance Id will simply be a series of decimal
numbers seperated by a '.':
========================================================================="
SYNTAX INTEGER {
unknown (1),
node (2),
shelf (3),
line (4),
switch (5),
lsp (6),
l2Interface(7),
l3Interface(8),
rowIndex(9)
}
MstiOrCistInstanceIndex ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This textual convention is an extension of the
MstiInstanceIndex convention. This extension permits the
additional value of zero, which means Common and Internal
Spanning Tree (CIST)."
SYNTAX Integer32 (0..16)
-- *****************************************************************************
-- Top level structure of this MIB.
-- *****************************************************************************
eventObjects OBJECT IDENTIFIER ::= { faultMIB 1 }
-- *****************************************************************************
-- Event Table
--
-- Event table reports all currently active fault events. Only normal type of
-- faults (i.e. faults that are not automatically and immediately cleared) are
-- present in the event table. Delta faults (i.e. faults that are automatically
-- cleared) are reported only by using trap messages.
-- *****************************************************************************
eventTable OBJECT-TYPE
SYNTAX SEQUENCE OF EventEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of currently active fault events. All faults
of normal type regardless of their severity level
are recorded in the event table. When a normal
type fault is cleared it is deleted from the event
table."
::= { eventObjects 1 }
eventEntry OBJECT-TYPE
SYNTAX EventEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing information about an
event in the event table."
INDEX { eventSeqNum }
::= { eventTable 1 }
EventEntry ::=
SEQUENCE {
eventSeqNum Integer32,
eventEventId EventIdNumber,
eventName DisplayString,
eventInstanceType InstanceType,
eventInstanceId DisplayString,
eventInstanceName DisplayString,
eventSeverity EventSeverity,
eventSetTime UtcTimeStamp,
eventDescription DisplayString,
eventServAffective EventServiceAffective,
eventInstanceIdNumber Integer32
}
eventSeqNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable represents the sequence number of an event.
Sequence number is incremented monotonically starting
from 0 until it reaches its maximum and wraps around back
to 0.
Sequence number is incremented when
- the state of a normal type fault is set on (the same sequence
number is present in the events table as well as in the trap
that is sent to notify about the fault on event)
- delta event occurs (sequence number present in trap message)
- the state of a normal type fault is set off (sequence number
present in trap that is sent to notify for clearing)."
::= { eventEntry 1 }
eventEventId OBJECT-TYPE
SYNTAX EventIdNumber
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable represents the event ID which uniquely
identifies the event in the entire system."
::= { eventEntry 2 }
eventName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..40))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable represents the name of the event, for
example 'Ethernet Link Down'"
::= { eventEntry 3 }
eventInstanceType OBJECT-TYPE
SYNTAX InstanceType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable represents the type of InstanceId of a
particular event in the event table. In brief
the instanceType refers to the type of sub-component
generating this event in the system, for example
switch (5). For more details see the textual
conventions section.
AFFECTS: eventInstanceId,
eventInstanceName"
::= { eventEntry 4 }
eventInstanceId OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable represents the InstanceId of a particular
event in the event current table. In brief the instanceId
refers to the sub-component generating this event in the
system, for example '1' for port 1. For more details see
the textual conventions section.
DEPENDS ON: eventInstanceType"
::= { eventEntry 5 }
eventInstanceName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable is mainly used to store additional information
about the sub-component that is generating an event. For
example this field may specify what cooling fan is faulty.
DEPENDS ON: eventInstanceType"
::= { eventEntry 6 }
eventSeverity OBJECT-TYPE
SYNTAX EventSeverity
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable dictates the urgency of action when a event
occurs. There are four severity levels - Critical, Major,
Minor, and Informational. Critical events are those, which
require immediate operator intervention to prevent/reduce
system down time. Major events require quick attention and
Minor events possibly require some attention. Informational
events indicate the occurrence of events that may need to be
investigated."
::= { eventEntry 7 }
eventSetTime OBJECT-TYPE
SYNTAX UtcTimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This table contains only normal events and this variable
represents the time when the event become active, i.e. the
number of seconds since Jan 1, 1970 12:00AM."
::= { eventEntry 8 }
eventDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable contains a description of the event and reasons
behind the event. This is a free format alpha-numeric string
that is set by the entity generating this event. This variable
may be empty if there is no usefull information to report.
The maximum length of this string is 255 characters."
::= { eventEntry 9 }
eventServAffective OBJECT-TYPE
SYNTAX EventServiceAffective
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates whether the event is service affective or not"
::= { eventEntry 10 }
eventInstanceIdNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable represents the InstanceId of a particular
event in the event current table. In brief the instanceId
refers to the sub-component generating this event in the
system, for example '1' for port 1. For more details see
the textual conventions section.
DEPENDS ON: eventInstanceType"
::= { eventEntry 11 }
-- fault Trap MIB
faultTrapsMIB MODULE-IDENTITY
LAST-UPDATED "200411011200Z" -- YYYY/MM/DD, HH/MM
ORGANIZATION "ZyXEL"
CONTACT-INFO ""
DESCRIPTION
"Fault event trap definitions"
::= { mgs3712 25 }
trapInfoObjects OBJECT IDENTIFIER ::= { faultTrapsMIB 1}
trapNotifications OBJECT IDENTIFIER ::= { faultTrapsMIB 2}
-- **************************************************************************
-- Local Textual Conventions
-- **************************************************************************
EventPersistence ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This textual convention indicates whether the event is delta
(automatically and immediately cleared) or normal (not
automatically cleared)."
SYNTAX INTEGER{
normal (1),
delta (2)
}
-- **************************************************************************
-- Trap information object definitions
-- **************************************************************************
trapRefSeqNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the former sequence number of a cleared event
in the event table. Not intended to read but only used in
trap notifications."
::= { trapInfoObjects 1 }
trapPersistence OBJECT-TYPE
SYNTAX EventPersistence
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates whether the event is delta (automatically and
immediately cleared) or normal (not automatically cleared).
Not intended to read but only used in trap notifications."
::= { trapInfoObjects 2 }
trapSenderNodeId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Represents the node ID of the sending network element. If not
supported should be set to 0. Not intended to read but only
used in trap notifications."
::= { trapInfoObjects 3 }
trapSenderStatus OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Represents the trap status. 0 means cleared, 1 means happened."
::= { trapInfoObjects 4 }
-- ***************************************************************************
-- Trap definitions
-- ***************************************************************************
eventOnTrap NOTIFICATION-TYPE
OBJECTS {
eventSeqNum,
eventEventId,
eventName,
eventSetTime,
eventSeverity,
eventInstanceType,
eventInstanceId,
eventInstanceName,
eventServAffective,
eventDescription,
eventInstanceIdNumber,
trapPersistence,
trapSenderNodeId,
trapSenderStatus,
sysObjectID}
STATUS current
DESCRIPTION
"This trap is used to inform network management system that a delta
fault event (events that are automatically cleared) has occured
or a normal fault event (not automatically cleared) state has
been set on.
Objects are used as follows:
- eventSeqNum is the sequence number of the event. For normal
type of events must equal to the sequence number of the event
in the events table.
- eventEventId specifies what fault event has occured.
- eventName specifies the name of the fault event.
- eventSetTime indicates when fault event has occured
(delta events) or when fault has been set on (normal events).
- eventSeverity reports the severity level of the event.
- eventInstanceType indicates what kind of object is faulty.
- eventInstanceId specifies what instance is faulty.
- eventInstanceName may contain textual description for
the faulty object.
- eventServAffective specifies whether the event is
immediately service affcetive.
- eventDescription reports possible additional information about the event.
- trapPersistence tells whether this event is a delta or normal event.
- trapSenderNodeId specifies the node ID of the sending network element if
configuring it is supported for the network element, otherwise 0.
- trapSenderStatus specifes the trap status.
- sysObjectID specifies what kind of equipment reports the fault event.
For more information see the eventTable specification"
::= { trapNotifications 1 }
eventClearedTrap NOTIFICATION-TYPE
OBJECTS {
eventSeqNum,
eventEventId,
eventSetTime,
eventInstanceType,
eventInstanceId,
eventInstanceIdNumber,
trapRefSeqNum,
trapSenderNodeId,
trapSenderStatus,
sysObjectID}
STATUS current
DESCRIPTION
"This trap is used to inform network management system that a normal
type fault event has been cleared (state set off).
Objects are used as follows:
- eventSeqNum is the sequence number of the this clearing event. Note that
the sequence number of the cleared event is reported in the trapRefSeqNum
object.
- eventEventId specifies what event has been cleared.
- eventSetTime indicates when fault event has been cleared.
- eventInstanceType indicates what kind of object has been
faulty.
- eventInstanceId specifies what instance has been faulty.
- trapRefSeqNum specifies the sequence number of the cleared event (i.e.
the sequence number was assigned for the event in the events table).
- trapSenderNodeId specifies the node ID of the sending network element if
configuring it is supported for the network element, otherwise 0.
- sysObjectID specifies what kind of equipment reports the clearing event.
For more information see the eventTable specification"
::= { trapNotifications 2 }
-- multicastPortSetup
multicastPortSetup OBJECT IDENTIFIER ::= { mgs3712 26 }
multicastPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF MulticastPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { multicastPortSetup 1 }
multicastPortEntry OBJECT-TYPE
SYNTAX MulticastPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in multicastPortTable."
INDEX { dot1dBasePort }
::= { multicastPortTable 1 }
MulticastPortEntry ::=
SEQUENCE {
multicastPortMaxGroupLimited EnabledStatus,
multicastPortMaxOfGroup INTEGER,
multicastPortIgmpFilteringProfile DisplayString,
multicastPortQuerierMode INTEGER,
multicastPortThrottlingAction INTEGER,
multicastPortLeaveMode INTEGER,
multicastPortLeaveTimeout INTEGER,
multicastPortFastLeaveTimeout INTEGER
}
multicastPortMaxGroupLimited OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { multicastPortEntry 2 }
multicastPortMaxOfGroup OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"0..255"
::= { multicastPortEntry 3 }
multicastPortIgmpFilteringProfile OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { multicastPortEntry 4 }
multicastPortQuerierMode OBJECT-TYPE
SYNTAX INTEGER {
auto(1),
fixed(2),
edge(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { multicastPortEntry 5 }
multicastPortThrottlingAction OBJECT-TYPE
SYNTAX INTEGER {
deny(1),
replace(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specify throttling action for each port"
::= { multicastPortEntry 6 }
multicastPortLeaveMode OBJECT-TYPE
SYNTAX INTEGER {
normal(0),
immediate(1),
fast(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { multicastPortEntry 7 }
multicastPortLeaveTimeout OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"200..6348800"
::= { multicastPortEntry 8 }
multicastPortFastLeaveTimeout OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"200..6348800"
::= { multicastPortEntry 9 }
-- multicastStatus
multicastStatus OBJECT IDENTIFIER ::= { mgs3712 27 }
multicastStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF MulticastStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { multicastStatus 1 }
multicastStatusEntry OBJECT-TYPE
SYNTAX MulticastStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in multicastStatusTable."
INDEX { multicastStatusVlanID, multicastStatusPort, multicastStatusGroup }
::= { multicastStatusTable 1 }
MulticastStatusEntry ::=
SEQUENCE {
multicastStatusIndex INTEGER,
multicastStatusVlanID INTEGER,
multicastStatusPort INTEGER,
multicastStatusGroup IpAddress
}
multicastStatusIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { multicastStatusEntry 1 }
multicastStatusVlanID OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { multicastStatusEntry 2 }
multicastStatusPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { multicastStatusEntry 3 }
multicastStatusGroup OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { multicastStatusEntry 4 }
multicastVlanStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF MulticastVlanStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { multicastStatus 2 }
-- multicastVlanStatusTable
multicastVlanStatusEntry OBJECT-TYPE
SYNTAX MulticastVlanStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in multicastVlanStatusTable."
INDEX { multicastVlanStatusVlanID }
::= { multicastVlanStatusTable 1 }
MulticastVlanStatusEntry ::=
SEQUENCE {
multicastVlanStatusVlanID INTEGER,
multicastVlanStatusType INTEGER,
multicastVlanQueryPort PortList
}
multicastVlanStatusVlanID OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { multicastVlanStatusEntry 1 }
multicastVlanStatusType OBJECT-TYPE
SYNTAX INTEGER {
dynamic(1),
mvr (2),
static(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { multicastVlanStatusEntry 2 }
multicastVlanQueryPort OBJECT-TYPE
SYNTAX PortList
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { multicastVlanStatusEntry 3 }
-- igmpSnpCountStatus
igmpSnpCountStatus OBJECT IDENTIFIER
::= { multicastStatus 3 }
-- igmpSnpV2CountTable
igmpSnpV2CountQueryRx OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { igmpSnpCountStatus 1 }
igmpSnpV2CountReportRx OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { igmpSnpCountStatus 2 }
igmpSnpV2CountLeaveRx OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { igmpSnpCountStatus 3 }
igmpSnpV2CountQueryRxDrop OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { igmpSnpCountStatus 4 }
igmpSnpV2CountReportRxDrop OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { igmpSnpCountStatus 5 }
igmpSnpV2CountLeaveRxDrop OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { igmpSnpCountStatus 6 }
igmpSnpV2CountQueryTx OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { igmpSnpCountStatus 7 }
igmpSnpV2CountReportTx OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { igmpSnpCountStatus 8 }
igmpSnpV2CountLeaveTx OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { igmpSnpCountStatus 9 }
-- igmpSnpV3CountTable
igmpSnpV3CountQueryRx OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { igmpSnpCountStatus 10 }
igmpSnpV3CountReportRx OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { igmpSnpCountStatus 11 }
igmpSnpV3CountQueryRxDrop OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { igmpSnpCountStatus 12 }
igmpSnpV3CountReportRxDrop OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { igmpSnpCountStatus 13 }
igmpSnpV3CountQueryTx OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { igmpSnpCountStatus 14 }
igmpSnpV3CountReportTx OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { igmpSnpCountStatus 15 }
-- igmpSnpCountVlanStatus
igmpSnpCountVlanTable OBJECT-TYPE
SYNTAX SEQUENCE OF IgmpSnpCountVlanEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION ""
::= { multicastStatus 4}
igmpSnpCountVlanEntry OBJECT-TYPE
SYNTAX IgmpSnpCountVlanEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in igmpGroupVlanStatus."
INDEX { igmpSnpCountVlanIndex }
::= { igmpSnpCountVlanTable 1 }
IgmpSnpCountVlanEntry ::=
SEQUENCE {
igmpSnpCountVlanIndex INTEGER,
igmpSnpV2CountVlanQueryRx INTEGER,
igmpSnpV2CountVlanReportRx INTEGER,
igmpSnpV2CountVlanLeaveRx INTEGER,
igmpSnpV2CountVlanQueryRxDrop INTEGER,
igmpSnpV2CountVlanReportRxDrop INTEGER,
igmpSnpV2CountVlanLeaveRxDrop INTEGER,
igmpSnpV2CountVlanQueryTx INTEGER,
igmpSnpV2CountVlanReportTx INTEGER,
igmpSnpV2CountVlanLeaveTx INTEGER,
igmpSnpV3CountVlanQueryRx INTEGER,
igmpSnpV3CountVlanReportRx INTEGER,
igmpSnpV3CountVlanQueryRxDrop INTEGER,
igmpSnpV3CountVlanReportRxDrop INTEGER,
igmpSnpV3CountVlanQueryTx INTEGER,
igmpSnpV3CountVlanReportTx INTEGER
}
igmpSnpCountVlanIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "Input vlan"
::={ igmpSnpCountVlanEntry 1}
igmpSnpV2CountVlanQueryRx OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "show igmpsnp Query Rx counters for vlan"
::={ igmpSnpCountVlanEntry 2}
igmpSnpV2CountVlanReportRx OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "show igmpsnp Report Rx counters for vlan"
::={ igmpSnpCountVlanEntry 3}
igmpSnpV2CountVlanLeaveRx OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "show igmpsnp Leave Rx counters for vlan"
::={ igmpSnpCountVlanEntry 4}
igmpSnpV2CountVlanQueryRxDrop OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "show igmpsnp Query Rx Error counters for vlan"
::={ igmpSnpCountVlanEntry 5}
igmpSnpV2CountVlanReportRxDrop OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "show igmpsnp Report Rx Error counters for vlan"
::={ igmpSnpCountVlanEntry 6}
igmpSnpV2CountVlanLeaveRxDrop OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "show igmpsnp Leave Rx Error counters for vlan"
::={ igmpSnpCountVlanEntry 7}
igmpSnpV2CountVlanQueryTx OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "show igmpsnp Query Tx counters for vlan"
::={ igmpSnpCountVlanEntry 8}
igmpSnpV2CountVlanReportTx OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "show igmpsnp Report Tx counters for vlan"
::={ igmpSnpCountVlanEntry 9}
igmpSnpV2CountVlanLeaveTx OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "show igmpsnp Leave Tx counters for vlan"
::={ igmpSnpCountVlanEntry 10}
igmpSnpV3CountVlanQueryRx OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "show igmpsnp Query Rx counters for vlan"
::={ igmpSnpCountVlanEntry 11}
igmpSnpV3CountVlanReportRx OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "show igmpsnp Report Rx counters for vlan"
::={ igmpSnpCountVlanEntry 12}
igmpSnpV3CountVlanQueryRxDrop OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "show igmpsnp Query Rx Error counters for vlan"
::={ igmpSnpCountVlanEntry 13}
igmpSnpV3CountVlanReportRxDrop OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "show igmpsnp Report Rx Error counters for vlan"
::={ igmpSnpCountVlanEntry 14}
igmpSnpV3CountVlanQueryTx OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "show igmpsnp Query Tx counters for vlan"
::={ igmpSnpCountVlanEntry 15}
igmpSnpV3CountVlanReportTx OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "show igmpsnp Report Tx counters for vlan"
::={ igmpSnpCountVlanEntry 16}
--igmpSnpCountPortStatus
igmpSnpCountPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF IgmpSnpCountPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION ""
::= { multicastStatus 5}
igmpSnpCountPortEntry OBJECT-TYPE
SYNTAX IgmpSnpCountPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in igmpSnpCountPortStatus."
INDEX { dot1dBasePort }
::= { igmpSnpCountPortTable 1 }
IgmpSnpCountPortEntry ::=
SEQUENCE {
igmpSnpV2CountPortQueryRx INTEGER,
igmpSnpV2CountPortReportRx INTEGER,
igmpSnpV2CountPortLeaveRx INTEGER,
igmpSnpV2CountPortReportRxDrop INTEGER,
igmpSnpV2CountPortLeaveRxDrop INTEGER,
igmpSnpV2CountPortReportTx INTEGER,
igmpSnpV2CountPortLeaveTx INTEGER,
igmpSnpV3CountPortQueryRx INTEGER,
igmpSnpV3CountPortReportRx INTEGER,
igmpSnpV3CountPortReportRxDrop INTEGER,
igmpSnpV3CountPortReportTx INTEGER
}
igmpSnpV2CountPortQueryRx OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "show igmpsnp Query Rx counters for port"
::={ igmpSnpCountPortEntry 1}
igmpSnpV2CountPortReportRx OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "show igmpsnp Report Rx counters for port"
::={ igmpSnpCountPortEntry 2}
igmpSnpV2CountPortLeaveRx OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "show igmpsnp Leave Rx counters for port"
::={ igmpSnpCountPortEntry 3}
igmpSnpV2CountPortReportRxDrop OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "show igmpsnp Report Rx Error counters for port"
::={ igmpSnpCountPortEntry 4}
igmpSnpV2CountPortLeaveRxDrop OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "show igmpsnp Leave Rx Error counters for port"
::={ igmpSnpCountPortEntry 5}
igmpSnpV2CountPortReportTx OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "show igmpsnp Report Tx counters for port"
::={ igmpSnpCountPortEntry 6}
igmpSnpV2CountPortLeaveTx OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "show igmpsnp Leave Tx counters for port"
::={ igmpSnpCountPortEntry 7}
igmpSnpV3CountPortQueryRx OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "show igmpsnp Query Rx counters for port"
::={ igmpSnpCountPortEntry 8}
igmpSnpV3CountPortReportRx OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "show igmpsnp Report Rx counters for port"
::={ igmpSnpCountPortEntry 9}
igmpSnpV3CountPortReportRxDrop OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "show igmpsnp Report Rx Error counters for port"
::={ igmpSnpCountPortEntry 10}
igmpSnpV3CountPortReportTx OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "show igmpsnp Report Tx counters for port"
::={ igmpSnpCountPortEntry 11}
-- igmpSnpGroupCountStatus
igmpSnpGroupCountStatus OBJECT IDENTIFIER
::= { multicastStatus 6 }
igmpSnpGroupCountNum OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "Show total IGMP snooping group number"
::= { igmpSnpGroupCountStatus 1 }
-- igmpGroupCountVlanTable
igmpSnpGroupCountVlanTable OBJECT-TYPE
SYNTAX SEQUENCE OF IgmpSnpGroupCountVlanEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION ""
::= { igmpSnpGroupCountStatus 2}
igmpSnpGroupCountVlanEntry OBJECT-TYPE
SYNTAX IgmpSnpGroupCountVlanEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in igmpSnpGroupVlanStatus."
INDEX { igmpSnpGroupCountVlanIndex }
::= { igmpSnpGroupCountVlanTable 1 }
IgmpSnpGroupCountVlanEntry ::=
SEQUENCE {
igmpSnpGroupCountVlanIndex INTEGER,
igmpSnpGroupCountVlanNum INTEGER
}
igmpSnpGroupCountVlanIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "Show IGMP snooping group index for vlan"
::= { igmpSnpGroupCountVlanEntry 1}
igmpSnpGroupCountVlanNum OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "Show IGMP snooping group number for vlan"
::={ igmpSnpGroupCountVlanEntry 2}
-- igmpGroupCountPortTable
igmpSnpGroupCountPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF IgmpSnpGroupCountPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION ""
::= {igmpSnpGroupCountStatus 3}
igmpSnpGroupCountPortEntry OBJECT-TYPE
SYNTAX IgmpSnpGroupCountPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in igmpGroupCountPortStatus."
INDEX { dot1dBasePort }
::= { igmpSnpGroupCountPortTable 1 }
IgmpSnpGroupCountPortEntry ::=
SEQUENCE {
igmpSnpGroupCountPortNum INTEGER
}
igmpSnpGroupCountPortNum OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "Show IGMP snooping group number for port"
::={ igmpSnpGroupCountPortEntry 1}
-- igmpFilteringProfileSetup
igmpFilteringProfileSetup OBJECT IDENTIFIER ::= { mgs3712 28 }
igmpFilteringMaxNumberOfProfile OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { igmpFilteringProfileSetup 1 }
igmpFilteringProfileTable OBJECT-TYPE
SYNTAX SEQUENCE OF IgmpFilteringProfileEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { igmpFilteringProfileSetup 2 }
igmpFilteringProfileEntry OBJECT-TYPE
SYNTAX IgmpFilteringProfileEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in igmpFilteringProfileTable."
INDEX { igmpFilteringProfileName, igmpFilteringProfileStartAddress, igmpFilteringProfileEndAddress }
::= { igmpFilteringProfileTable 1 }
IgmpFilteringProfileEntry ::=
SEQUENCE {
igmpFilteringProfileName DisplayString,
igmpFilteringProfileStartAddress IpAddress,
igmpFilteringProfileEndAddress IpAddress,
igmpFilteringProfileRowStatus RowStatus
}
igmpFilteringProfileName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { igmpFilteringProfileEntry 1 }
igmpFilteringProfileStartAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { igmpFilteringProfileEntry 2 }
igmpFilteringProfileEndAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { igmpFilteringProfileEntry 3 }
igmpFilteringProfileRowStatus OBJECT-TYPE
SYNTAX RowStatus
ACCESS read-create
STATUS mandatory
DESCRIPTION
""
::= { igmpFilteringProfileEntry 4 }
-- MVRSetup
mvrSetup OBJECT IDENTIFIER ::= { mgs3712 29 }
maxNumberOfMVR OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { mvrSetup 1 }
mvrTable OBJECT-TYPE
SYNTAX SEQUENCE OF MvrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { mvrSetup 2 }
mvrEntry OBJECT-TYPE
SYNTAX MvrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in mvrTable."
INDEX { mvrVlanID }
::= { mvrTable 1 }
MvrEntry ::=
SEQUENCE {
mvrVlanID INTEGER,
mvrName DisplayString,
mvrMode INTEGER,
mvrRowStatus RowStatus,
mvr8021pPriority INTEGER
}
mvrVlanID OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"1..4094"
::= { mvrEntry 1 }
mvrName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { mvrEntry 2 }
mvrMode OBJECT-TYPE
SYNTAX INTEGER {
dynamic(0),
compatible(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { mvrEntry 3 }
mvrRowStatus OBJECT-TYPE
SYNTAX RowStatus
ACCESS read-create
STATUS mandatory
DESCRIPTION
""
::= { mvrEntry 4 }
mvr8021pPriority OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Set the 802.1p priority of control messages within MVR (0~7)"
::= { mvrEntry 5 }
mvrPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF MvrPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { mvrSetup 3 }
mvrPortEntry OBJECT-TYPE
SYNTAX MvrPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in mvrPortTable."
INDEX { mvrVlanID, dot1dBasePort }
::= { mvrPortTable 1 }
MvrPortEntry ::=
SEQUENCE {
mvrPortRole INTEGER,
mvrPortTagging EnabledStatus
}
mvrPortRole OBJECT-TYPE
SYNTAX INTEGER {
none(1),
source_port(2),
receiver_port(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { mvrPortEntry 1 }
mvrPortTagging OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { mvrPortEntry 2 }
maxNumberOfMvrGroup OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { mvrSetup 4 }
mvrGroupTable OBJECT-TYPE
SYNTAX SEQUENCE OF MvrGroupEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { mvrSetup 5 }
mvrGroupEntry OBJECT-TYPE
SYNTAX MvrGroupEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in mvrGroupTable."
INDEX { mvrVlanID, mvrGroupName }
::= { mvrGroupTable 1 }
MvrGroupEntry ::=
SEQUENCE {
mvrGroupName DisplayString,
mvrGroupStartAddress IpAddress,
mvrGroupEndAddress IpAddress,
mvrGroupRowStatus RowStatus
}
mvrGroupName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { mvrGroupEntry 1 }
mvrGroupStartAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { mvrGroupEntry 2 }
mvrGroupEndAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { mvrGroupEntry 3 }
mvrGroupRowStatus OBJECT-TYPE
SYNTAX RowStatus
ACCESS read-create
STATUS mandatory
DESCRIPTION
""
::= { mvrGroupEntry 4 }
-- clusterSetup
clusterSetup OBJECT IDENTIFIER ::= { mgs3712 30 }
-- clusterManager
clusterManager OBJECT IDENTIFIER ::= { clusterSetup 1 }
clusterMaxNumOfManager OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { clusterManager 1 }
-- clusterManagerTable
clusterManagerTable OBJECT-TYPE
SYNTAX SEQUENCE OF ClusterManagerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { clusterManager 2 }
clusterManagerEntry OBJECT-TYPE
SYNTAX ClusterManagerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in clusterManagerTable."
INDEX { clusterManagerVid }
::= { clusterManagerTable 1 }
ClusterManagerEntry ::=
SEQUENCE {
clusterManagerVid INTEGER,
clusterManagerName DisplayString,
clusterManagerRowStatus RowStatus
}
clusterManagerVid OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { clusterManagerEntry 1 }
clusterManagerName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { clusterManagerEntry 2 }
clusterManagerRowStatus OBJECT-TYPE
SYNTAX RowStatus
ACCESS read-create
STATUS mandatory
DESCRIPTION
""
::= { clusterManagerEntry 3 }
-- clusterMembers
clusterMembers OBJECT IDENTIFIER ::= { clusterSetup 2 }
clusterMaxNumOfMember OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { clusterMembers 1 }
-- clusterMemberTable
clusterMemberTable OBJECT-TYPE
SYNTAX SEQUENCE OF ClusterMemberEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { clusterMembers 2 }
clusterMemberEntry OBJECT-TYPE
SYNTAX ClusterMemberEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in clusterMemberTable."
INDEX { clusterMemberMac }
::= { clusterMemberTable 1 }
ClusterMemberEntry ::=
SEQUENCE {
clusterMemberMac MacAddress,
clusterMemberName DisplayString,
clusterMemberModel DisplayString,
clusterMemberPassword DisplayString,
clusterMemberRowStatus RowStatus
}
clusterMemberMac OBJECT-TYPE
SYNTAX MacAddress
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { clusterMemberEntry 1 }
clusterMemberName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { clusterMemberEntry 2 }
clusterMemberModel OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { clusterMemberEntry 3 }
clusterMemberPassword OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { clusterMemberEntry 4 }
clusterMemberRowStatus OBJECT-TYPE
SYNTAX RowStatus
ACCESS read-create
STATUS mandatory
DESCRIPTION
""
::= { clusterMemberEntry 5 }
-- clusterCandidates
clusterCandidates OBJECT IDENTIFIER ::= { clusterSetup 3 }
-- clusterCandidateTable
clusterCandidateTable OBJECT-TYPE
SYNTAX SEQUENCE OF ClusterCandidateEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { clusterCandidates 1 }
clusterCandidateEntry OBJECT-TYPE
SYNTAX ClusterCandidateEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in clusterCandidateTable."
INDEX { clusterCandidateMac }
::= { clusterCandidateTable 1 }
ClusterCandidateEntry ::=
SEQUENCE {
clusterCandidateMac MacAddress,
clusterCandidateName DisplayString,
clusterCandidateModel DisplayString
}
clusterCandidateMac OBJECT-TYPE
SYNTAX MacAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { clusterCandidateEntry 1 }
clusterCandidateName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { clusterCandidateEntry 2 }
clusterCandidateModel OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { clusterCandidateEntry 3 }
-- clusterStatus
clusterStatus OBJECT IDENTIFIER ::= { clusterSetup 4 }
clusterStatusRole OBJECT-TYPE
SYNTAX INTEGER {
none(0),
manager(1),
member(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { clusterStatus 1 }
clusterStatusManager OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { clusterStatus 2 }
clsuterStatusNumOfMember OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { clusterStatus 3 }
-- clusterStatusMemberTable
clusterStatusMemberTable OBJECT-TYPE
SYNTAX SEQUENCE OF ClusterStatusMemberEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { clusterStatus 4 }
clusterStatusMemberEntry OBJECT-TYPE
SYNTAX ClusterStatusMemberEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in clusterStatusMemberTable."
INDEX { clusterStatusMemberMac }
::= { clusterStatusMemberTable 1 }
ClusterStatusMemberEntry ::=
SEQUENCE {
clusterStatusMemberMac MacAddress,
clusterStatusMemberName DisplayString,
clusterStatusMemberModel DisplayString,
clusterStatusMemberStatus INTEGER
}
clusterStatusMemberMac OBJECT-TYPE
SYNTAX MacAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { clusterStatusMemberEntry 1 }
clusterStatusMemberName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { clusterStatusMemberEntry 2 }
clusterStatusMemberModel OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { clusterStatusMemberEntry 3 }
clusterStatusMemberStatus OBJECT-TYPE
SYNTAX INTEGER {
error(0),
online(1),
offline(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { clusterStatusMemberEntry 4 }
-- sysLogSetup
sysLogSetup OBJECT IDENTIFIER ::= { mgs3712 31 }
sysLogState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"sysLog enabled/disabled for the switch."
::= { sysLogSetup 1 }
-- sysLogTypeTable
sysLogTypeTable OBJECT-TYPE
SYNTAX SEQUENCE OF SysLogTypeEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { sysLogSetup 2 }
sysLogTypeEntry OBJECT-TYPE
SYNTAX SysLogTypeEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in sysLogTypeTable."
INDEX { sysLogTypeIndex }
::= { sysLogTypeTable 1 }
SysLogTypeEntry ::=
SEQUENCE {
sysLogTypeIndex INTEGER,
sysLogTypeName DisplayString,
sysLogTypeState EnabledStatus,
sysLogTypeFacility INTEGER
}
sysLogTypeIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { sysLogTypeEntry 1 }
sysLogTypeName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { sysLogTypeEntry 2 }
sysLogTypeState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { sysLogTypeEntry 3 }
sysLogTypeFacility OBJECT-TYPE
SYNTAX INTEGER {
local_user0(0),
local_user1(1),
local_user2(2),
local_user3(3),
local_user4(4),
local_user5(5),
local_user6(6),
local_user7(7)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { sysLogTypeEntry 4 }
-- sysLogServerTable
sysLogServerTable OBJECT-TYPE
SYNTAX SEQUENCE OF SysLogServerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { sysLogSetup 3 }
sysLogServerEntry OBJECT-TYPE
SYNTAX SysLogServerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in sysLogServerTable."
INDEX { sysLogServerAddress }
::= { sysLogServerTable 1 }
SysLogServerEntry ::=
SEQUENCE {
sysLogServerAddress IpAddress,
sysLogServerLogLevel INTEGER,
sysLogServerRowStatus RowStatus
}
sysLogServerAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { sysLogServerEntry 1 }
sysLogServerLogLevel OBJECT-TYPE
SYNTAX INTEGER {
level0(0),
level0-1(1),
level0-2(2),
level0-3(3),
level0-4(4),
level0-5(5),
level0-6(6),
level0-7(7)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { sysLogServerEntry 2 }
sysLogServerRowStatus OBJECT-TYPE
SYNTAX RowStatus
ACCESS read-create
STATUS mandatory
DESCRIPTION
""
::= { sysLogServerEntry 3 }
-- MRSTP
mrstp OBJECT IDENTIFIER ::= { mgs3712 32 }
mrstpSetup OBJECT IDENTIFIER ::= { mrstp 1 }
mrstpBridgeTable OBJECT-TYPE
SYNTAX SEQUENCE OF MrstpBridgeEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { mrstpSetup 1 }
mrstpBridgeEntry OBJECT-TYPE
SYNTAX MrstpBridgeEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in mrstpBridgeTable."
INDEX { mrstpBridgeIndex }
::= { mrstpBridgeTable 1 }
MrstpBridgeEntry ::=
SEQUENCE {
mrstpBridgeIndex INTEGER,
mrstpState INTEGER,
mrstpProtocolSpecification INTEGER,
mrstpPriority INTEGER,
mrstpTimeSinceTopologyChange TimeTicks,
mrstpTopChanges Counter,
mrstpDesignatedRoot BridgeId,
mrstpRootCost INTEGER,
mrstpRootPort INTEGER,
mrstpMaxAge Timeout,
mrstpHelloTime Timeout,
mrstpHoldTime INTEGER,
mrstpForwardDelay Timeout,
mrstpBridgeMaxAge Timeout,
mrstpBridgeHelloTime Timeout,
mrstpBridgeForwardDelay Timeout
}
-- the dot1dStp group
-- Implementation of the dot1dStp group is optional. It is
-- implemented by those bridges that support the Spanning Tree
-- Protocol.
mrstpBridgeIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The tree index of the MRSTP."
::= { mrstpBridgeEntry 1 }
mrstpState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enabled/disabled on the mrstp bridge."
::= { mrstpBridgeEntry 2 }
mrstpProtocolSpecification OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
decLb100(2),
ieee8021d(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"An indication of what version of the Spanning
Tree Protocol is being run. The value
'decLb100(2)' indicates the DEC LANbridge 100
Spanning Tree protocol. IEEE 802.1d
implementations will return 'ieee8021d(3)'. If
future versions of the IEEE Spanning Tree Protocol
are released that are incompatible with the
current version a new value will be defined."
::= { mrstpBridgeEntry 3 }
mrstpPriority OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The value of the write-able portion of the Bridge
ID, i.e., the first two octets of the (8 octet
long) Bridge ID. The other (last) 6 octets of the
Bridge ID are given by the value of
dot1dBaseBridgeAddress."
REFERENCE
"IEEE 802.1D-1990: Section 4.5.3.7"
::= { mrstpBridgeEntry 4 }
mrstpTimeSinceTopologyChange OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The time (in hundredths of a second) since the
last time a topology change was detected by the
bridge entity."
REFERENCE
"IEEE 802.1D-1990: Section 6.8.1.1.3"
::= { mrstpBridgeEntry 5 }
mrstpTopChanges OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of topology changes detected by
this bridge since the management entity was last
reset or initialized."
REFERENCE
"IEEE 802.1D-1990: Section 6.8.1.1.3"
::= { mrstpBridgeEntry 6 }
mrstpDesignatedRoot OBJECT-TYPE
SYNTAX BridgeId
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The bridge identifier of the root of the spanning
tree as determined by the Spanning Tree Protocol
as executed by this node. This value is used as
the Root Identifier parameter in all Configuration
Bridge PDUs originated by this node."
REFERENCE
"IEEE 802.1D-1990: Section 4.5.3.1"
::= { mrstpBridgeEntry 7 }
mrstpRootCost OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The cost of the path to the root as seen from
this bridge."
REFERENCE
"IEEE 802.1D-1990: Section 4.5.3.2"
::= { mrstpBridgeEntry 8 }
mrstpRootPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The port number of the port which offers the
lowest cost path from this bridge to the root
bridge."
REFERENCE
"IEEE 802.1D-1990: Section 4.5.3.3"
::= { mrstpBridgeEntry 9 }
mrstpMaxAge OBJECT-TYPE
SYNTAX Timeout
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The maximum age of Spanning Tree Protocol
information learned from the network on any port
before it is discarded, in units of hundredths of
a second. This is the actual value that this
bridge is currently using."
REFERENCE
"IEEE 802.1D-1990: Section 4.5.3.4"
::= { mrstpBridgeEntry 10 }
mrstpHelloTime OBJECT-TYPE
SYNTAX Timeout
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The amount of time between the transmission of
Configuration bridge PDUs by this node on any port
when it is the root of the spanning tree or trying
to become so, in units of hundredths of a second.
This is the actual value that this bridge is
currently using."
REFERENCE
"IEEE 802.1D-1990: Section 4.5.3.5"
::= { mrstpBridgeEntry 11 }
mrstpHoldTime OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This time value determines the interval length
during which no more than two Configuration bridge
PDUs shall be transmitted by this node, in units
of hundredths of a second."
REFERENCE
"IEEE 802.1D-1990: Section 4.5.3.14"
::= { mrstpBridgeEntry 12 }
mrstpForwardDelay OBJECT-TYPE
SYNTAX Timeout
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This time value, measured in units of hundredths
of a second, controls how fast a port changes its
spanning state when moving towards the Forwarding
state. The value determines how long the port
stays in each of the Listening and Learning
states, which precede the Forwarding state. This
value is also used, when a topology change has
been detected and is underway, to age all dynamic
entries in the Forwarding Database. [Note that
this value is the one that this bridge is
currently using, in contrast to
mrstpBridgeForwardDelay which is the value that
this bridge and all others would start using
if/when this bridge were to become the root.]"
REFERENCE
"IEEE 802.1D-1990: Section 4.5.3.6"
::= { mrstpBridgeEntry 13 }
mrstpBridgeMaxAge OBJECT-TYPE
SYNTAX Timeout (600..4000)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The value that all bridges use for MaxAge when
this bridge is acting as the root. Note that
802.1D-1990 specifies that the range for this
parameter is related to the value of
mrstpBridgeHelloTime. The granularity of this
timer is specified by 802.1D-1990 to be 1 second.
An agent may return a badValue error if a set is
attempted to a value which is not a whole number
of seconds."
REFERENCE
"IEEE 802.1D-1990: Section 4.5.3.8"
::= { mrstpBridgeEntry 14 }
mrstpBridgeHelloTime OBJECT-TYPE
SYNTAX Timeout (100..1000)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The value that all bridges use for HelloTime when
this bridge is acting as the root. The
granularity of this timer is specified by 802.1D-
1990 to be 1 second. An agent may return a
badValue error if a set is attempted to a value
which is not a whole number of seconds."
REFERENCE
"IEEE 802.1D-1990: Section 4.5.3.9"
::= { mrstpBridgeEntry 15 }
mrstpBridgeForwardDelay OBJECT-TYPE
SYNTAX Timeout (400..3000)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The value that all bridges use for ForwardDelay
when this bridge is acting as the root. Note that
802.1D-1990 specifies that the range for this
parameter is related to the value of
mrstpBridgeMaxAge. The granularity of this
timer is specified by 802.1D-1990 to be 1 second.
An agent may return a badValue error if a set is
attempted to a value which is not a whole number
of seconds."
REFERENCE
"IEEE 802.1D-1990: Section 4.5.3.10"
::= { mrstpBridgeEntry 16 }
-- The Spanning Tree Port Table
mrstpPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF MrstpPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table that contains port-specific information
for the Spanning Tree Protocol."
::= { mrstpSetup 2 }
mrstpPortEntry OBJECT-TYPE
SYNTAX MrstpPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of information maintained by every port
about the Spanning Tree Protocol state for that
port."
INDEX { mrstpPort }
::= { mrstpPortTable 1 }
MrstpPortEntry ::=
SEQUENCE {
mrstpPort
INTEGER,
mrstpPortPriority
INTEGER,
mrstpPortState
INTEGER,
mrstpPortEnable
INTEGER,
mrstpPortPathCost
INTEGER,
mrstpPortDesignatedRoot
BridgeId,
mrstpPortDesignatedCost
INTEGER,
mrstpPortDesignatedBridge
BridgeId,
mrstpPortDesignatedPort
OCTET STRING,
mrstpPortForwardTransitions
Counter,
mrstpPortOnBridgeIndex
INTEGER
}
mrstpPort OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The port number of the port for which this entry
contains Spanning Tree Protocol management
information."
REFERENCE
"IEEE 802.1D-1990: Section 6.8.2.1.2"
::= { mrstpPortEntry 1 }
mrstpPortPriority OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The value of the priority field which is
contained in the first (in network byte order)
octet of the (2 octet long) Port ID. The other
octet of the Port ID is given by the value of
mrstpPort."
REFERENCE
"IEEE 802.1D-1990: Section 4.5.5.1"
::= { mrstpPortEntry 2 }
mrstpPortState OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
blocking(2),
listening(3),
learning(4),
forwarding(5),
broken(6)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The port's current state as defined by
application of the Spanning Tree Protocol. This
state controls what action a port takes on
reception of a frame. If the bridge has detected
a port that is malfunctioning it will place that
port into the broken(6) state. For ports which
are disabled (see mrstpPortEnable), this object
will have a value of disabled(1)."
REFERENCE
"IEEE 802.1D-1990: Section 4.5.5.2"
::= { mrstpPortEntry 3 }
mrstpPortEnable OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The enabled/disabled status of the port."
REFERENCE
"IEEE 802.1D-1990: Section 4.5.5.2"
::= { mrstpPortEntry 4 }
mrstpPortPathCost OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The contribution of this port to the path cost of
paths towards the spanning tree root which include
this port. 802.1D-1990 recommends that the
default value of this parameter be in inverse
proportion to the speed of the attached LAN."
REFERENCE
"IEEE 802.1D-1990: Section 4.5.5.3"
::= { mrstpPortEntry 5 }
mrstpPortDesignatedRoot OBJECT-TYPE
SYNTAX BridgeId
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The unique Bridge Identifier of the Bridge
recorded as the Root in the Configuration BPDUs
transmitted by the Designated Bridge for the
segment to which the port is attached."
REFERENCE
"IEEE 802.1D-1990: Section 4.5.5.4"
::= { mrstpPortEntry 6 }
mrstpPortDesignatedCost OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The path cost of the Designated Port of the
segment connected to this port. This value is
compared to the Root Path Cost field in received
bridge PDUs."
REFERENCE
"IEEE 802.1D-1990: Section 4.5.5.5"
::= { mrstpPortEntry 7 }
mrstpPortDesignatedBridge OBJECT-TYPE
SYNTAX BridgeId
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Bridge Identifier of the bridge which this
port considers to be the Designated Bridge for
this port's segment."
REFERENCE
"IEEE 802.1D-1990: Section 4.5.5.6"
::= { mrstpPortEntry 8 }
mrstpPortDesignatedPort OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (2))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Port Identifier of the port on the Designated
Bridge for this port's segment."
REFERENCE
"IEEE 802.1D-1990: Section 4.5.5.7"
::= { mrstpPortEntry 9 }
mrstpPortForwardTransitions OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of times this port has transitioned
from the Learning state to the Forwarding state."
::= { mrstpPortEntry 10 }
mrstpPortOnBridgeIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indetify the bridge index that this port joined to in MRSTP."
::= { mrstpPortEntry 11 }
-- MRSTP Trap
mrstpNotifications OBJECT IDENTIFIER ::= { mrstp 2 }
newRoot NOTIFICATION-TYPE
OBJECTS {
mrstpBridgeIndex
}
STATUS current
DESCRIPTION
""
::= { mrstpNotifications 1 }
topologyChange NOTIFICATION-TYPE
OBJECTS {
mrstpBridgeIndex
}
STATUS current
DESCRIPTION
""
::= { mrstpNotifications 2 }
-- classifierSetup
classifierSetup OBJECT IDENTIFIER ::= { mgs3712 33 }
classifierRuleTable OBJECT-TYPE
SYNTAX SEQUENCE OF ClassifierRuleEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { classifierSetup 1 }
classifierRuleEntry OBJECT-TYPE
SYNTAX ClassifierRuleEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in classifierRuleTable."
INDEX {classifierName }
::= { classifierRuleTable 1 }
ClassifierRuleEntry ::=
SEQUENCE {
classifierName DisplayString,
classifierEnable INTEGER,
classifierPacketFormat INTEGER,
classifierVlanId INTEGER,
classifier8021pPriority INTEGER,
classifierEtherType INTEGER,
classifierSrcMAC MacAddress,
classifierIncomingPort INTEGER,
classifierDstMAC MacAddress,
classifierDSCP INTEGER,
classifierIpProtocol INTEGER,
classifierEstablishOnly INTEGER,
classifierSrcIp IpAddress,
classifierSrcIpMask INTEGER,
classifierSrcSocket INTEGER,
classifierDstIp IpAddress,
classifierDstIpMask INTEGER,
classifierDstSocket INTEGER,
classifierRowstatus RowStatus
}
classifierName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Name of classifier rule."
::= { classifierRuleEntry 1 }
classifierEnable OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Classifier rule enabled/disabled."
::= { classifierRuleEntry 2 }
classifierPacketFormat OBJECT-TYPE
SYNTAX INTEGER
{
all(1),
ethernetII-untagged(2),
ethernetII-tagged(3),
ethernet802_3-untagged(4),
ethernet802_3-tagged(5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Packet format for classifier rule. All(1), 802.3 untagged(2), 802.3 tagged(3), EthernetII untagged(4), EthernetII tagged(5)."
::= { classifierRuleEntry 3 }
classifierVlanId OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Vlan id for classifer rule, 1~4094. Value 0 means any"
::= { classifierRuleEntry 4 }
classifier8021pPriority OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"802.1p priority for classifier rule, 0~7. Value -1 means any"
::= { classifierRuleEntry 5 }
classifierEtherType OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Ether type for classifier rule, in decimal expression. Value 65535 means any"
::= { classifierRuleEntry 6 }
classifierSrcMAC OBJECT-TYPE
SYNTAX MacAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Source mac address for classifier rule. 00:00:00:00:00:00 means any"
::= { classifierRuleEntry 7 }
classifierIncomingPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Incoming Port for classifier rule. Value 65536 means any"
::= { classifierRuleEntry 8 }
classifierDstMAC OBJECT-TYPE
SYNTAX MacAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Destination mac address for classifier rule. 00:00:00:00:00:00 means any"
::= { classifierRuleEntry 9 }
classifierDSCP OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DSCP for classifier rule. Value -1 means any"
::= { classifierRuleEntry 10 }
classifierIpProtocol OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"IP Protocol for classifier rule. Value 255 means any"
::= { classifierRuleEntry 11 }
classifierEstablishOnly OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION
"IP Protocol for EstablishOnly in classifier rule"
::= { classifierRuleEntry 12 }
classifierSrcIp OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Source IP address for classifier rule. 0.0.0.0 means any"
::= { classifierRuleEntry 13 }
classifierSrcIpMask OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Source IP Mask for classifier rule."
::= { classifierRuleEntry 14 }
classifierSrcSocket OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Source Socket Number for classifier rule. Value 0 means any"
::= { classifierRuleEntry 15 }
classifierDstIp OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Destination IP address for classifier rule. 0.0.0.0 means any"
::= { classifierRuleEntry 16 }
classifierDstIpMask OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Destination IP Mask for classifier rule"
::= { classifierRuleEntry 17 }
classifierDstSocket OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Destination Socket Number for classifier rule. Value 0 means any"
::= { classifierRuleEntry 18 }
classifierRowstatus OBJECT-TYPE
SYNTAX RowStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Row Status for classifier rule"
::= { classifierRuleEntry 19 }
-- policySetup
policySetup OBJECT IDENTIFIER ::= { mgs3712 34 }
policyTable OBJECT-TYPE
SYNTAX SEQUENCE OF PolicyEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { policySetup 1 }
policyEntry OBJECT-TYPE
SYNTAX PolicyEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in policyTable."
INDEX {policyName }
::= { policyTable 1 }
PolicyEntry ::=
SEQUENCE {
policyName DisplayString,
policyEnable INTEGER,
policyClassifier DisplayString,
policyEgressPort INTEGER,
policy8021pPriority INTEGER,
policyDSCP INTEGER,
policyTOS INTEGER,
policyBandwidth INTEGER,
policyOutOfProfileDSCP INTEGER,
policyForwardingAction INTEGER,
policyPriorityAction INTEGER,
policyDiffServAction INTEGER,
policyOutgoingAction BITS,
policyMeteringEnable INTEGER,
policyOutOfProfileAction BITS,
policyRowstatus RowStatus
}
policyName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Name of policy rule."
::= { policyEntry 1 }
policyEnable OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Policy rule enabled/disabled."
::= { policyEntry 2 }
policyClassifier OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Classifier of policy rule."
::= { policyEntry 3 }
policyEgressPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Egress Port for policy rule"
::= { policyEntry 5 }
policy8021pPriority OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"802.1p priority for policy rule, 0~7."
::= { policyEntry 7 }
policyDSCP OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DSCP for policy rule."
::= { policyEntry 8 }
policyTOS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"TOS for policy rule, 0~7"
::= { policyEntry 9 }
policyBandwidth OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bandwidth for policy rule"
::= { policyEntry 10 }
policyOutOfProfileDSCP OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Out Of Profile DSCP for policy rule."
::= { policyEntry 11 }
policyForwardingAction OBJECT-TYPE
SYNTAX INTEGER
{
no-change(1),
discard-the-packet(2),
do-not-drop-the-matching-frame-previously-marked-for-dopping(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Forwarding Action for policy rule"
::= { policyEntry 12 }
policyPriorityAction OBJECT-TYPE
SYNTAX INTEGER
{
no-change(1),
set-the-packets-802_1-priority(2),
send-the-packet-to-priority-queue(3),
replace-the-802_1-priority-field-with-the-IP-TOS-value(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Priority Action for policy rule"
::= { policyEntry 13}
policyDiffServAction OBJECT-TYPE
SYNTAX INTEGER
{
no-change(1),
set-the-packets-TOS-field(2),
replace-the-IP-TOS-field-with-the-802_1-priority-value(3),
set-the-Diffserv-Codepoint-field-in-the-frame(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DiffServ Action for policy rule"
::= { policyEntry 14}
policyOutgoingAction OBJECT-TYPE
SYNTAX BITS {
send-the-packet-to-the-mirror-port(0),
send-the-packet-to-the-egress-port(1),
send-the-matching-frames-to-the-egress-port(2),
set-the-packets-VLAN-ID(3)
}
ACCESS read-create
STATUS current
DESCRIPTION
"Outgoing Action for policy rule. Started bit is from MSB bit7 (bit7~bit0). "
::= { policyEntry 15 }
policyMeteringEnable OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Metering for Policy rule enabled/disabled."
::= { policyEntry 16 }
policyOutOfProfileAction OBJECT-TYPE
SYNTAX BITS {
drop-the-packet(0),
change-the-DSCP-value(1),
set-Out-Drop-Precedence(2),
do-not-drop-the-matching-frame-previously-marked-for-dropping(3)
}
ACCESS read-create
STATUS current
DESCRIPTION
"Out Of Profile Action for policy rule. Started bit is from MSB bit7 (bit7~bit0)."
::= { policyEntry 17 }
policyRowstatus OBJECT-TYPE
SYNTAX RowStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Row Status for policy rule"
::= { policyEntry 18 }
-- radiusServerSetup
radiusServerSetup OBJECT IDENTIFIER ::= { mgs3712 35 }
radiusAuthServerSetup OBJECT IDENTIFIER ::= { radiusServerSetup 1 }
radiusAuthServerMode OBJECT-TYPE
SYNTAX INTEGER{
index-priority(1),
round-robin(2),
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { radiusAuthServerSetup 1 }
radiusAuthServerTimeout OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { radiusAuthServerSetup 2 }
-- radiusAuthServerTable
radiusAuthServerTable OBJECT-TYPE
SYNTAX SEQUENCE OF RadiusAuthServerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { radiusAuthServerSetup 3 }
radiusAuthServerEntry OBJECT-TYPE
SYNTAX RadiusAuthServerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in radiusAuthServerTable."
INDEX { radiusAuthServerIndex }
::= { radiusAuthServerTable 1 }
RadiusAuthServerEntry ::=
SEQUENCE {
radiusAuthServerIndex INTEGER,
radiusAuthServerIpAddr IpAddress,
radiusAuthServerUdpPort INTEGER,
radiusAuthServerSharedSecret DisplayString
}
radiusAuthServerIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { radiusAuthServerEntry 1 }
radiusAuthServerIpAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { radiusAuthServerEntry 2 }
radiusAuthServerUdpPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { radiusAuthServerEntry 3 }
radiusAuthServerSharedSecret OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { radiusAuthServerEntry 4 }
radiusAcctServerSetup OBJECT IDENTIFIER ::= { radiusServerSetup 2 }
radiusAcctServerTimeout OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { radiusAcctServerSetup 1 }
-- radiusAcctServerTable
radiusAcctServerTable OBJECT-TYPE
SYNTAX SEQUENCE OF RadiusAcctServerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { radiusAcctServerSetup 2 }
radiusAcctServerEntry OBJECT-TYPE
SYNTAX RadiusAcctServerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in radiusAcctServerTable."
INDEX { radiusAcctServerIndex }
::= { radiusAcctServerTable 1 }
RadiusAcctServerEntry ::=
SEQUENCE {
radiusAcctServerIndex INTEGER,
radiusAcctServerIpAddr IpAddress,
radiusAcctServerUdpPort INTEGER,
radiusAcctServerSharedSecret DisplayString
}
radiusAcctServerIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { radiusAcctServerEntry 1 }
radiusAcctServerIpAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { radiusAcctServerEntry 2 }
radiusAcctServerUdpPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { radiusAcctServerEntry 3 }
radiusAcctServerSharedSecret OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { radiusAcctServerEntry 4 }
-- tacacsServerSetup
tacacsServerSetup OBJECT IDENTIFIER ::= { mgs3712 36 }
tacacsAuthServerSetup OBJECT IDENTIFIER ::= { tacacsServerSetup 1 }
tacacsAuthServerMode OBJECT-TYPE
SYNTAX INTEGER{
index-priority(1),
round-robin(2),
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { tacacsAuthServerSetup 1 }
tacacsAuthServerTimeout OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { tacacsAuthServerSetup 2 }
-- tacacsAuthServerTable
tacacsAuthServerTable OBJECT-TYPE
SYNTAX SEQUENCE OF TacacsAuthServerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { tacacsAuthServerSetup 3 }
tacacsAuthServerEntry OBJECT-TYPE
SYNTAX TacacsAuthServerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in tacacsAuthServerTable."
INDEX { tacacsAuthServerIndex }
::= { tacacsAuthServerTable 1 }
TacacsAuthServerEntry ::=
SEQUENCE {
tacacsAuthServerIndex INTEGER,
tacacsAuthServerIpAddr IpAddress,
tacacsAuthServerTcpPort INTEGER,
tacacsAuthServerSharedSecret DisplayString
}
tacacsAuthServerIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { tacacsAuthServerEntry 1 }
tacacsAuthServerIpAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { tacacsAuthServerEntry 2 }
tacacsAuthServerTcpPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { tacacsAuthServerEntry 3 }
tacacsAuthServerSharedSecret OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { tacacsAuthServerEntry 4 }
tacacsAcctServerSetup OBJECT IDENTIFIER ::= { tacacsServerSetup 2 }
tacacsAcctServerTimeout OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { tacacsAcctServerSetup 1 }
-- tacacsAcctServerTable
tacacsAcctServerTable OBJECT-TYPE
SYNTAX SEQUENCE OF TacacsAcctServerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { tacacsAcctServerSetup 2 }
tacacsAcctServerEntry OBJECT-TYPE
SYNTAX TacacsAcctServerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in tacacsAcctServerTable."
INDEX { tacacsAcctServerIndex }
::= { tacacsAcctServerTable 1 }
TacacsAcctServerEntry ::=
SEQUENCE {
tacacsAcctServerIndex INTEGER,
tacacsAcctServerIpAddr IpAddress,
tacacsAcctServerTcpPort INTEGER,
tacacsAcctServerSharedSecret DisplayString
}
tacacsAcctServerIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { tacacsAcctServerEntry 1 }
tacacsAcctServerIpAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { tacacsAcctServerEntry 2 }
tacacsAcctServerTcpPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { tacacsAcctServerEntry 3 }
tacacsAcctServerSharedSecret OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { tacacsAcctServerEntry 4 }
-- aaaSetup
aaaSetup OBJECT IDENTIFIER ::= { mgs3712 37 }
authenticationSetup OBJECT IDENTIFIER ::= { aaaSetup 1 }
-- authenticationTypeTable
authenticationTypeTable OBJECT-TYPE
SYNTAX SEQUENCE OF AuthenticationTypeEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { authenticationSetup 1 }
authenticationTypeEntry OBJECT-TYPE
SYNTAX AuthenticationTypeEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in authenticationTypeTable."
INDEX { authenticationTypeName }
::= { authenticationTypeTable 1 }
AuthenticationTypeEntry ::=
SEQUENCE {
authenticationTypeName DisplayString,
authenticationTypeMethodList OCTET STRING
}
authenticationTypeName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { authenticationTypeEntry 1 }
authenticationTypeMethodList OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { authenticationTypeEntry 2 }
accountingSetup OBJECT IDENTIFIER ::= { aaaSetup 2 }
accountingUpdatePeriod OBJECT-TYPE
SYNTAX Integer32
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { accountingSetup 1 }
-- accountingTypeTable
accountingTypeTable OBJECT-TYPE
SYNTAX SEQUENCE OF AccountingTypeEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { accountingSetup 2 }
accountingTypeEntry OBJECT-TYPE
SYNTAX AccountingTypeEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in accountingTypeTable."
INDEX { accountingTypeName }
::= { accountingTypeTable 1 }
AccountingTypeEntry ::=
SEQUENCE {
accountingTypeName DisplayString,
accountingTypeActive EnabledStatus,
accountingTypeBroadcast EnabledStatus,
accountingTypeMode INTEGER,
accountingTypeMethod INTEGER,
accountingTypePrivilege INTEGER
}
accountingTypeName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { accountingTypeEntry 1 }
accountingTypeActive OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { accountingTypeEntry 2 }
accountingTypeBroadcast OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { accountingTypeEntry 3 }
accountingTypeMode OBJECT-TYPE
SYNTAX INTEGER{
not-available(255),
start-stop(1),
stop-only(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { accountingTypeEntry 4 }
accountingTypeMethod OBJECT-TYPE
SYNTAX INTEGER{
radius(1),
tacacs(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { accountingTypeEntry 5 }
accountingTypePrivilege OBJECT-TYPE
SYNTAX INTEGER{
not-available(255),
privilege-0(0),
privilege-1(1),
privilege-2(2),
privilege-3(3),
privilege-4(4),
privilege-5(5),
privilege-6(6),
privilege-7(7),
privilege-8(8),
privilege-9(9),
privilege-10(10),
privilege-11(11),
privilege-12(12),
privilege-13(13),
privilege-14(14)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { accountingTypeEntry 6 }
authorizationSetup OBJECT IDENTIFIER ::= { aaaSetup 3 }
-- authorizationTypeTable
authorizationTypeTable OBJECT-TYPE
SYNTAX SEQUENCE OF AuthorizationTypeEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { authorizationSetup 1 }
authorizationTypeEntry OBJECT-TYPE
SYNTAX AuthorizationTypeEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in authorizationTypeTable."
INDEX { authorizationTypeName }
::= { authorizationTypeTable 1 }
AuthorizationTypeEntry ::=
SEQUENCE {
authorizationTypeName DisplayString,
authorizationTypeActive EnabledStatus,
authorizationTypeMethod INTEGER
}
authorizationTypeName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { authorizationTypeEntry 1 }
authorizationTypeActive OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { authorizationTypeEntry 2 }
authorizationTypeMethod OBJECT-TYPE
SYNTAX INTEGER{
radius(1),
tacacs(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { authorizationTypeEntry 3 }
---------------------------------------------------
--
-- vlan stacking
--
---------------------------------------------------
-- vlanStackSetup
vlanStackSetup OBJECT IDENTIFIER ::= { mgs3712 38 }
vlanStackState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"VLAN Stacking enabled/disabled for the switch."
::= { vlanStackSetup 1 }
-- vlanStackTpid OBJECT-TYPE
-- SYNTAX INTEGER
-- ACCESS read-write
-- STATUS mandatory
-- DESCRIPTION
-- "SP TPID in hex format, e.g. 8100."
-- ::= { vlanStackSetup 2 }
-- vlanStackPortTable
vlanStackPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF VlanStackPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { vlanStackSetup 3 }
vlanStackPortEntry OBJECT-TYPE
SYNTAX VlanStackPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in vlanStackPortTable."
INDEX { dot1dBasePort }
::= { vlanStackPortTable 1 }
VlanStackPortEntry ::=
SEQUENCE {
vlanStackPortMode INTEGER,
vlanStackPortVid INTEGER,
vlanStackPortPrio INTEGER,
vlanStackTunnelPortTpid INTEGER
}
vlanStackPortMode OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
access(2),
tunnel(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Mode of the port. Set Normal to have the switch ignore frames received
(or transmitted) on this port with VLAN stacking tags.
Anything you configure in SPVID and Priority are ignored.
Set Access mode to have the switch add the SP TPID tag to all incoming
frames received on this port. Set Access mode for ingress ports at the
edge of the service provider's network. Set Tunnel mode (available for
Gigabit ports only) for egress ports at the edge of the service provider's
network. In order to support VLAN stacking on a port, the port must be able
to allow frames of 1526 Bytes (1522 Bytes + 4 Bytes for the second tag)
to pass through it. normal (1), Access (2), tunnel (3)"
::= { vlanStackPortEntry 1 }
vlanStackPortVid OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"VLAN ID used in service provider tag."
::= { vlanStackPortEntry 2 }
vlanStackPortPrio OBJECT-TYPE
SYNTAX INTEGER {
prioriry-0(0),
prioriry-1(1),
prioriry-2(2),
prioriry-3(3),
prioriry-4(4),
prioriry-5(5),
prioriry-6(6),
prioriry-7(7)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Priority value for service provider tag.
0 is the lowest priority level and 7 is the highest."
::= { vlanStackPortEntry 3 }
vlanStackTunnelPortTpid OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Tunnel Port TPID in hex format, e.g. 8100."
::= { vlanStackPortEntry 4 }
-- selectiveQinQTable
selectiveQinQTable OBJECT-TYPE
SYNTAX SEQUENCE OF SelectiveQinQEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { vlanStackSetup 4 }
selectiveQinQEntry OBJECT-TYPE
SYNTAX SelectiveQinQEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in selective qinq table"
INDEX { selectiveQinQPort, selectiveQinQCvid }
::= { selectiveQinQTable 1 }
SelectiveQinQEntry ::=
SEQUENCE {
selectiveQinQName DisplayString,
selectiveQinQPort INTEGER,
selectiveQinQCvid INTEGER,
selectiveQinQSpvid INTEGER,
selectiveQinQPriority INTEGER,
selectiveQinQRowStatus RowStatus
}
selectiveQinQName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The name of selective qinq entry"
::= { selectiveQinQEntry 1 }
selectiveQinQPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"interface port id"
::= { selectiveQinQEntry 2 }
selectiveQinQCvid OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"inner vid"
::= { selectiveQinQEntry 3 }
selectiveQinQSpvid OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"outer vid"
::= { selectiveQinQEntry 4 }
selectiveQinQPriority OBJECT-TYPE
SYNTAX INTEGER {
prioriry-0(0),
prioriry-1(1),
prioriry-2(2),
prioriry-3(3),
prioriry-4(4),
prioriry-5(5),
prioriry-6(6),
prioriry-7(7)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"priority"
::= { selectiveQinQEntry 5 }
selectiveQinQRowStatus OBJECT-TYPE
SYNTAX RowStatus
ACCESS read-create
STATUS mandatory
DESCRIPTION
""
::= { selectiveQinQEntry 6 }
-- diffservSetup
diffservSetup OBJECT IDENTIFIER ::= { mgs3712 39 }
diffservState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { diffservSetup 1 }
-- diffservMapTable
diffservMapTable OBJECT-TYPE
SYNTAX SEQUENCE OF DiffservMapEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { diffservSetup 2 }
diffservMapEntry OBJECT-TYPE
SYNTAX DiffservMapEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in diffservMapTable."
INDEX { diffservMapDscp }
::= { diffservMapTable 1 }
DiffservMapEntry ::=
SEQUENCE {
diffservMapDscp INTEGER,
diffservMapPriority INTEGER
}
diffservMapDscp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"0-63"
::= { diffservMapEntry 1 }
diffservMapPriority OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"0-7"
::= { diffservMapEntry 2 }
-- diffservPortTable
diffservPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF DiffservPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { diffservSetup 3 }
diffservPortEntry OBJECT-TYPE
SYNTAX DiffservPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in diffservPortTable."
INDEX { dot1dBasePort }
::= { diffservPortTable 1 }
DiffservPortEntry ::=
SEQUENCE {
diffservPortState EnabledStatus
}
diffservPortState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { diffservPortEntry 1 }
-- protocol-based VLAN
protoBasedVlanSetup OBJECT IDENTIFIER ::= { mgs3712 40 }
protoBasedVlanTable OBJECT-TYPE
SYNTAX SEQUENCE OF ProtoBasedVlanEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { protoBasedVlanSetup 1 }
protoBasedVlanEntry OBJECT-TYPE
SYNTAX ProtoBasedVlanEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in protoBasedVlanTable."
INDEX { protoBasedVlanPort, protoBasedVlanPacketType, protoBasedVlanEtherType }
::= { protoBasedVlanTable 1 }
ProtoBasedVlanEntry ::=
SEQUENCE {
protoBasedVlanPort INTEGER,
protoBasedVlanPacketType INTEGER,
protoBasedVlanEtherType INTEGER,
protoBasedVlanName DisplayString,
protoBasedVlanVid INTEGER,
protoBasedVlanPriority INTEGER,
protoBasedVlanState RowStatus
}
protoBasedVlanPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { protoBasedVlanEntry 1 }
protoBasedVlanPacketType OBJECT-TYPE
SYNTAX INTEGER {
etherII(1),
snap(2),
llc(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { protoBasedVlanEntry 2 }
protoBasedVlanEtherType OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { protoBasedVlanEntry 3 }
protoBasedVlanName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { protoBasedVlanEntry 4 }
protoBasedVlanVid OBJECT-TYPE
SYNTAX INTEGER (1..4094)
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { protoBasedVlanEntry 5 }
protoBasedVlanPriority OBJECT-TYPE
SYNTAX INTEGER (0..7)
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { protoBasedVlanEntry 6 }
protoBasedVlanState OBJECT-TYPE
SYNTAX RowStatus
ACCESS read-create
STATUS mandatory
DESCRIPTION
""
::= { protoBasedVlanEntry 7 }
---------------------------------------------------
--
-- dhcp snooping
--
---------------------------------------------------
dhcpSnp OBJECT IDENTIFIER ::= { mgs3712 100 }
--
-- dhcp snooping vlan table
--
dhcpSnpVlanTable OBJECT-TYPE
SYNTAX SEQUENCE OF DhcpSnpVlanEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { dhcpSnp 1 }
dhcpSnpVlanEntry OBJECT-TYPE
SYNTAX DhcpSnpVlanEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION ""
INDEX { dhcpSnpVlanEntryVid }
::= { dhcpSnpVlanTable 1 }
DhcpSnpVlanEntry ::=
SEQUENCE {
dhcpSnpVlanEntryVid INTEGER,
dhcpSnpVlanEntryEnable EnabledStatus,
dhcpSnpVlanEntryOption82Enable EnabledStatus,
dhcpSnpVlanEntryInfo EnabledStatus
}
dhcpSnpVlanEntryVid OBJECT-TYPE
SYNTAX INTEGER (1..4094)
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { dhcpSnpVlanEntry 1 }
dhcpSnpVlanEntryEnable OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { dhcpSnpVlanEntry 2 }
dhcpSnpVlanEntryOption82Enable OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { dhcpSnpVlanEntry 3 }
dhcpSnpVlanEntryInfo OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { dhcpSnpVlanEntry 4 }
--
-- dhcp snooping interface table
--
dhcpSnpPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF DhcpSnpPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { dhcpSnp 2 }
dhcpSnpPortEntry OBJECT-TYPE
SYNTAX DhcpSnpPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION ""
INDEX { dhcpSnpPortEntryPort }
::= { dhcpSnpPortTable 1 }
DhcpSnpPortEntry ::=
SEQUENCE {
dhcpSnpPortEntryPort INTEGER,
dhcpSnpPortEntryTrust EnabledStatus,
dhcpSnpPortEntryRate INTEGER
}
dhcpSnpPortEntryPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { dhcpSnpPortEntry 1 }
dhcpSnpPortEntryTrust OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { dhcpSnpPortEntry 2 }
dhcpSnpPortEntryRate OBJECT-TYPE
SYNTAX INTEGER (0..2048)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"0 means unlimited"
::= { dhcpSnpPortEntry 3 }
--
-- dhcp snooping binding table
--
dhcpSnpBindTable OBJECT-TYPE
SYNTAX SEQUENCE OF DhcpSnpBindEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { dhcpSnp 3 }
dhcpSnpBindEntry OBJECT-TYPE
SYNTAX DhcpSnpBindEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION ""
INDEX { dhcpSnpBindEntryMac, dhcpSnpBindEntryVid }
::= { dhcpSnpBindTable 1 }
DhcpSnpBindEntry ::=
SEQUENCE {
dhcpSnpBindEntryMac MacAddress,
dhcpSnpBindEntryVid INTEGER,
dhcpSnpBindEntryIP IpAddress,
dhcpSnpBindEntryLease INTEGER,
dhcpSnpBindEntryType INTEGER,
dhcpSnpBindEntryPort INTEGER
}
dhcpSnpBindEntryMac OBJECT-TYPE
SYNTAX MacAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { dhcpSnpBindEntry 1 }
dhcpSnpBindEntryVid OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { dhcpSnpBindEntry 2 }
dhcpSnpBindEntryIP OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { dhcpSnpBindEntry 3 }
dhcpSnpBindEntryLease OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { dhcpSnpBindEntry 4 }
dhcpSnpBindEntryType OBJECT-TYPE
SYNTAX INTEGER { dynamic(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { dhcpSnpBindEntry 5 }
dhcpSnpBindEntryPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { dhcpSnpBindEntry 6 }
--
-- dhcp snooping
--
dhcpSnpEnable OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { dhcpSnp 4 }
--
-- dhcp snooping database
--
dhcpSnpDb OBJECT IDENTIFIER ::= { dhcpSnp 5 }
dhcpSnpDbAbort OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { dhcpSnpDb 1 }
dhcpSnpDbWriteDelay OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { dhcpSnpDb 2 }
dhcpSnpDbUrl OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { dhcpSnpDb 3 }
dhcpSnpDbUrlRenew OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { dhcpSnpDb 4 }
dhcpSnpDbStat OBJECT IDENTIFIER ::= { dhcpSnpDb 5 }
dhcpSnpDbStatClear OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { dhcpSnpDbStat 1 }
dhcpSnpDbStatAgentRunning OBJECT-TYPE
SYNTAX INTEGER { none(0), read(1), write(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { dhcpSnpDbStat 2 }
dhcpSnpDbStatDelayExpiry OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { dhcpSnpDbStat 3 }
dhcpSnpDbStatAbortExpiry OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { dhcpSnpDbStat 4 }
dhcpSnpDbStatLastSuccTime OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { dhcpSnpDbStat 5 }
dhcpSnpDbStatLastFailTime OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { dhcpSnpDbStat 6 }
dhcpSnpDbStatLastFailReason OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { dhcpSnpDbStat 7 }
dhcpSnpDbStatTotalAttempt OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { dhcpSnpDbStat 8 }
dhcpSnpDbStatStartupFail OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { dhcpSnpDbStat 9 }
dhcpSnpDbStatSuccTrans OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { dhcpSnpDbStat 10 }
dhcpSnpDbStatFailTrans OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { dhcpSnpDbStat 11 }
dhcpSnpDbStatSuccRead OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { dhcpSnpDbStat 12 }
dhcpSnpDbStatFailRead OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { dhcpSnpDbStat 13 }
dhcpSnpDbStatSuccWrite OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { dhcpSnpDbStat 14 }
dhcpSnpDbStatFailWrite OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { dhcpSnpDbStat 15 }
dhcpSnpDbStatFirstSuccAccess OBJECT-TYPE
SYNTAX INTEGER { none(0), read(1), write(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { dhcpSnpDbStat 16 }
dhcpSnpDbStatLastIgnoreBindCol OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Last ignored: binding collision"
::= { dhcpSnpDbStat 17 }
dhcpSnpDbStatLastIgnoreExpireLease OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Last ignored: expired leases"
::= { dhcpSnpDbStat 18 }
dhcpSnpDbStatLastIgnoreInvalidIntf OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Last ignored: invalid interface"
::= { dhcpSnpDbStat 19 }
dhcpSnpDbStatLastIgnoreUnsuppVlan OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Last ignored: unsupported vlans"
::= { dhcpSnpDbStat 20 }
dhcpSnpDbStatLastIgnoreParse OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Last ignored: parsing error"
::= { dhcpSnpDbStat 21 }
dhcpSnpDbStatTotalIgnoreBindCol OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total ignored: binding collision"
::= { dhcpSnpDbStat 22 }
dhcpSnpDbStatTotalIgnoreExpireLease OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total ignored: expired leases"
::= { dhcpSnpDbStat 23 }
dhcpSnpDbStatTotalIgnoreInvalidIntf OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total ignored: invalid interface"
::= { dhcpSnpDbStat 24 }
dhcpSnpDbStatTotalIgnoreUnsuppVlan OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total ignored: unsupported vlans"
::= { dhcpSnpDbStat 25 }
dhcpSnpDbStatTotalIgnoreParse OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total ignored: parsing error"
::= { dhcpSnpDbStat 26 }
dhcpSnpDbStatFirstSuccessAccess OBJECT-TYPE
SYNTAX INTEGER{
none(0),
read(1),
write(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"First Success Access"
::={ dhcpSnpDbStat 27}
--
-- dhcp snooping dhcp vlan
--
dhcpSnpDhcpVlan OBJECT IDENTIFIER ::= { dhcpSnp 6 }
dhcpSnpDhcpVlanVid OBJECT-TYPE
SYNTAX INTEGER (0..4094)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"0: disable DHCP VLAN."
::= { dhcpSnpDhcpVlan 1 }
-----------------------------------------------------------------
--
-- ip source guard
--
-----------------------------------------------------------------
ipsg OBJECT IDENTIFIER ::= { mgs3712 101 }
ipsgTable OBJECT-TYPE
SYNTAX SEQUENCE OF IpsgEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { ipsg 1 }
ipsgEntry OBJECT-TYPE
SYNTAX IpsgEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION ""
INDEX { ipsgEntryMac, ipsgEntryVid }
::= { ipsgTable 1 }
IpsgEntry ::=
SEQUENCE {
ipsgEntryMac MacAddress,
ipsgEntryVid INTEGER,
ipsgEntryIp IpAddress,
ipsgEntryLease INTEGER,
ipsgEntryType INTEGER,
ipsgEntryPort INTEGER,
ipsgEntryState RowStatus
}
ipsgEntryMac OBJECT-TYPE
SYNTAX MacAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { ipsgEntry 1 }
ipsgEntryVid OBJECT-TYPE
SYNTAX INTEGER (1.. 4094)
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { ipsgEntry 2 }
ipsgEntryIp OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { ipsgEntry 3 }
ipsgEntryLease OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"second"
::= { ipsgEntry 4 }
ipsgEntryType OBJECT-TYPE
SYNTAX INTEGER { static(1), dhcp(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { ipsgEntry 5 }
ipsgEntryPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"0 means any port"
::= { ipsgEntry 6 }
ipsgEntryState OBJECT-TYPE
SYNTAX RowStatus
ACCESS read-create
STATUS mandatory
DESCRIPTION
""
::= { ipsgEntry 7 }
-----------------------------------------------------------------
--
-- arpInspect
--
-----------------------------------------------------------------
arpInspect OBJECT IDENTIFIER ::= { mgs3712 102 }
arpInspectSetup OBJECT IDENTIFIER ::= { arpInspect 1 }
arpInspectState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { arpInspectSetup 1 }
arpInspectFilterAgingTime OBJECT-TYPE
SYNTAX INTEGER (0..2147483647)
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { arpInspectSetup 2 }
arpInspectLog OBJECT IDENTIFIER ::= { arpInspectSetup 3 }
arpInspectLogEntries OBJECT-TYPE
SYNTAX INTEGER (0..1024)
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { arpInspectLog 1 }
arpInspectLogRate OBJECT-TYPE
SYNTAX INTEGER (0..1024)
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { arpInspectLog 2 }
arpInspectLogInterval OBJECT-TYPE
SYNTAX INTEGER (0..2147483647)
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { arpInspectLog 3 }
--arpInspectVlanTable
arpInspectVlanTable OBJECT-TYPE
SYNTAX SEQUENCE OF ArpInspectVlanEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { arpInspectSetup 4 }
arpInspectVlanEntry OBJECT-TYPE
SYNTAX ArpInspectVlanEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION ""
INDEX { arpInspectVlanVid }
::= { arpInspectVlanTable 1 }
ArpInspectVlanEntry ::=
SEQUENCE {
arpInspectVlanVid INTEGER,
arpInspectVlanLog INTEGER,
arpInspectVlanStatus INTEGER
}
arpInspectVlanVid OBJECT-TYPE
SYNTAX INTEGER (1..4094)
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { arpInspectVlanEntry 1 }
arpInspectVlanLog OBJECT-TYPE
SYNTAX INTEGER {
all (1),
none (2),
permit (3),
deny (4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { arpInspectVlanEntry 2 }
arpInspectVlanStatus OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { arpInspectVlanEntry 3 }
--arpInspectPortTable
arpInspectPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF ArpInspectPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { arpInspectSetup 5 }
arpInspectPortEntry OBJECT-TYPE
SYNTAX ArpInspectPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION ""
INDEX { arpInspectPortIndex }
::= { arpInspectPortTable 1 }
ArpInspectPortEntry ::=
SEQUENCE {
arpInspectPortIndex INTEGER,
arpInspectPortTrust INTEGER,
arpInspectPortRate INTEGER,
arpInspectPortInterval INTEGER
}
arpInspectPortIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { arpInspectPortEntry 1 }
arpInspectPortTrust OBJECT-TYPE
SYNTAX INTEGER {
trusted(1),
untrusted(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { arpInspectPortEntry 2 }
arpInspectPortRate OBJECT-TYPE
SYNTAX INTEGER (0..2048)
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { arpInspectPortEntry 3 }
arpInspectPortInterval OBJECT-TYPE
SYNTAX INTEGER (1..15)
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { arpInspectPortEntry 4 }
arpInspectStatus OBJECT IDENTIFIER ::= { arpInspect 2 }
arpInspectFilterClear OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { arpInspectStatus 1 }
arpInspectLogClear OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { arpInspectStatus 2 }
--arpInspectFilterTable
arpInspectFilterTable OBJECT-TYPE
SYNTAX SEQUENCE OF ArpInspectFilterEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { arpInspectStatus 3 }
arpInspectFilterEntry OBJECT-TYPE
SYNTAX ArpInspectFilterEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION ""
INDEX { arpInspectFilterMac, arpInspectFilterVid }
::= { arpInspectFilterTable 1 }
ArpInspectFilterEntry ::=
SEQUENCE {
arpInspectFilterMac MacAddress,
arpInspectFilterVid INTEGER,
arpInspectFilterPort INTEGER,
arpInspectFilterExpiry INTEGER,
arpInspectFilterReason INTEGER,
arpInspectFilterRowStatus RowStatus
}
arpInspectFilterMac OBJECT-TYPE
SYNTAX MacAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { arpInspectFilterEntry 1 }
arpInspectFilterVid OBJECT-TYPE
SYNTAX INTEGER (1..4094)
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { arpInspectFilterEntry 2 }
arpInspectFilterPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { arpInspectFilterEntry 3 }
arpInspectFilterExpiry OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { arpInspectFilterEntry 4 }
arpInspectFilterReason OBJECT-TYPE
SYNTAX INTEGER {
macVid(1),
port(2),
ip(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { arpInspectFilterEntry 5 }
arpInspectFilterRowStatus OBJECT-TYPE
SYNTAX RowStatus
ACCESS read-create
STATUS mandatory
DESCRIPTION
""
::= { arpInspectFilterEntry 6 }
--arpInspectLogTable
arpInspectLogTable OBJECT-TYPE
SYNTAX SEQUENCE OF ArpInspectLogEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { arpInspectStatus 4 }
arpInspectLogEntry OBJECT-TYPE
SYNTAX ArpInspectLogEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION ""
INDEX { arpInspectLogMac, arpInspectLogVid, arpInspectLogPort, arpInspectLogIp, arpInspectLogReason }
::= { arpInspectLogTable 1 }
ArpInspectLogEntry ::=
SEQUENCE {
arpInspectLogMac MacAddress,
arpInspectLogVid INTEGER,
arpInspectLogPort INTEGER,
arpInspectLogIp IpAddress,
arpInspectLogNumPkt INTEGER,
arpInspectLogReason INTEGER,
arpInspectLogTime DateAndTime
}
arpInspectLogMac OBJECT-TYPE
SYNTAX MacAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { arpInspectLogEntry 1 }
arpInspectLogVid OBJECT-TYPE
SYNTAX INTEGER (1..4094)
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { arpInspectLogEntry 2 }
arpInspectLogPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { arpInspectLogEntry 3 }
arpInspectLogIp OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { arpInspectLogEntry 4 }
arpInspectLogNumPkt OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { arpInspectLogEntry 5 }
arpInspectLogReason OBJECT-TYPE
SYNTAX INTEGER {
deny (1),
denyStatic (2),
denyDHCP (3),
permitStatic (4),
permitDHCP (5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { arpInspectLogEntry 6 }
arpInspectLogTime OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { arpInspectLogEntry 7 }
--arpInspectStatisticsTable
arpInspectStatisticsTable OBJECT-TYPE
SYNTAX SEQUENCE OF ArpInspectStatisticsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { arpInspectStatus 5 }
arpInspectStatisticsEntry OBJECT-TYPE
SYNTAX ArpInspectStatisticsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION ""
INDEX { arpInspectStatisticsVid }
::= { arpInspectStatisticsTable 1 }
ArpInspectStatisticsEntry ::=
SEQUENCE {
arpInspectStatisticsVid INTEGER,
arpInspectStatisticsReceived Counter,
arpInspectStatisticsRequest Counter,
arpInspectStatisticsReply Counter,
arpInspectStatisticsForward Counter,
arpInspectStatisticsDrop Counter,
arpInspectStatisticsClear EnabledStatus
}
arpInspectStatisticsVid OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { arpInspectStatisticsEntry 1 }
arpInspectStatisticsReceived OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { arpInspectStatisticsEntry 2 }
arpInspectStatisticsRequest OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { arpInspectStatisticsEntry 3 }
arpInspectStatisticsReply OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { arpInspectStatisticsEntry 4 }
arpInspectStatisticsForward OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { arpInspectStatisticsEntry 5 }
arpInspectStatisticsDrop OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { arpInspectStatisticsEntry 6 }
arpInspectStatisticsClear OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { arpInspectStatisticsEntry 7 }
-- trTCMSetup
trTCMSetup OBJECT IDENTIFIER ::= { mgs3712 103 }
trTCMState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Two-rate three color marker enabled/disabled for the switch."
::= { trTCMSetup 1 }
trTCMMode OBJECT-TYPE
SYNTAX INTEGER {
color-aware(0),
color-blind(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { trTCMSetup 2 }
-- trTCMPortTable
trTCMPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF TrTCMPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { trTCMSetup 3 }
trTCMPortEntry OBJECT-TYPE
SYNTAX TrTCMPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in trTCMPortTable."
INDEX { dot1dBasePort }
::= { trTCMPortTable 1 }
TrTCMPortEntry ::=
SEQUENCE {
trTCMPortState EnabledStatus,
trTCMPortCIR INTEGER,
trTCMPortPIR INTEGER,
trTCMPortDscpGreen INTEGER,
trTCMPortDscpYellow INTEGER,
trTCMPortDscpRed INTEGER
}
trTCMPortState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-create
STATUS mandatory
DESCRIPTION
"Two-rate three color marker enabled/disabled on the port."
::= { trTCMPortEntry 1 }
trTCMPortCIR OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Allowed CIR in pkts/s."
::= { trTCMPortEntry 2 }
trTCMPortPIR OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Allowed PIR in pkts/s."
::= { trTCMPortEntry 3 }
trTCMPortDscpGreen OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"0-63"
::= { trTCMPortEntry 4 }
trTCMPortDscpYellow OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"0-63"
::= { trTCMPortEntry 5 }
trTCMPortDscpRed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"0-63"
::= { trTCMPortEntry 6 }
-- loopGuardSetup
loopGuardSetup OBJECT IDENTIFIER ::= { mgs3712 104 }
loopGuardState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { loopGuardSetup 1 }
-- loopGuardPortTable
loopGuardPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF LoopGuardPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { loopGuardSetup 2 }
loopGuardPortEntry OBJECT-TYPE
SYNTAX LoopGuardPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in loopGuardPortTable."
INDEX { dot1dBasePort }
::= { loopGuardPortTable 1 }
LoopGuardPortEntry ::=
SEQUENCE {
loopGuardPortState EnabledStatus
}
loopGuardPortState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { loopGuardPortEntry 1 }
-- subnetBasedVlanSetup
subnetBasedVlanSetup OBJECT IDENTIFIER ::= { mgs3712 105 }
subnetBasedVlanState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"subnet-based vlan feature enabled/disabled for the switch."
::= { subnetBasedVlanSetup 1 }
dhcpVlanOverrideState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"dhcp vlan override enabled/disabled when subnet-based vlan is enabled."
::= { subnetBasedVlanSetup 2 }
subnetBasedVlanTable OBJECT-TYPE
SYNTAX SEQUENCE OF SubnetBasedVlanEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { subnetBasedVlanSetup 3 }
subnetBasedVlanEntry OBJECT-TYPE
SYNTAX SubnetBasedVlanEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in subnetBasedVlanTable."
INDEX {subnetBasedVlanSrcIp , subnetBasedVlanSrcMaskBit}
::= { subnetBasedVlanTable 1 }
SubnetBasedVlanEntry ::=
SEQUENCE {
subnetBasedVlanSrcIp IpAddress,
subnetBasedVlanSrcMaskBit INTEGER,
subnetBasedVlanName DisplayString,
subnetBasedVlanVid INTEGER,
subnetBasedVlanPriority INTEGER,
subnetBasedVlanEntryState RowStatus
}
subnetBasedVlanSrcIp OBJECT-TYPE
SYNTAX IpAddress
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"source ip for subnet-based vlan entry"
::= { subnetBasedVlanEntry 1 }
subnetBasedVlanSrcMaskBit OBJECT-TYPE
SYNTAX INTEGER (1..32)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"source ip mask-bits for subnet-based vlan entry"
::= { subnetBasedVlanEntry 2 }
subnetBasedVlanName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"name for subnet-based vlan entry"
::= { subnetBasedVlanEntry 3 }
subnetBasedVlanVid OBJECT-TYPE
SYNTAX INTEGER (1..4094)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"vid for subnet-based vlan entry"
::= { subnetBasedVlanEntry 4 }
subnetBasedVlanPriority OBJECT-TYPE
SYNTAX INTEGER (0..7)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"priority for subnet-based vlan entry"
::= { subnetBasedVlanEntry 5 }
subnetBasedVlanEntryState OBJECT-TYPE
SYNTAX RowStatus
ACCESS read-create
STATUS mandatory
DESCRIPTION
""
::= { subnetBasedVlanEntry 6 }
-- MAC Authentication
macAuthenticationSetup OBJECT IDENTIFIER ::= { mgs3712 106 }
macAuthenticationState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { macAuthenticationSetup 1 }
macAuthenticationNamePrefix OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { macAuthenticationSetup 2 }
macAuthenticationPassword OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { macAuthenticationSetup 3 }
macAuthenticationTimeout OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { macAuthenticationSetup 4 }
-- macAuthenticationPortTable
macAuthenticationPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF MacAuthenticationPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { macAuthenticationSetup 5 }
macAuthenticationPortEntry OBJECT-TYPE
SYNTAX MacAuthenticationPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in macAuthenticationPortTable."
INDEX { dot1dBasePort }
::= { macAuthenticationPortTable 1 }
MacAuthenticationPortEntry ::=
SEQUENCE {
macAuthenticationPortState EnabledStatus
}
macAuthenticationPortState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { macAuthenticationPortEntry 1 }
-- MSTP
mstp OBJECT IDENTIFIER ::= { mgs3712 107 }
-- mstpGen group reflects configurations/statuses
-- the Bridge as a unit
mstpGen OBJECT IDENTIFIER ::= { mstp 1}
mstpGenState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enabled/disabled on the mrstp bridge."
::= { mstpGen 1 }
mstpGenCfgIdName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The configuration name that identifies the MST
region and is used as one of the inputs in the
computation of the MST Configuration Identifier."
REFERENCE
"12.12.3.4.2.b)"
::= { mstpGen 2 }
mstpGenCfgIdRevLevel OBJECT-TYPE
SYNTAX Integer32
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object identifies the MST revision that
identifies the MST region and is used as one
of the inputs in the computation of the MST
configuration Identifier."
REFERENCE
"12.12.3.4.2.c)"
::= { mstpGen 3 }
mstpGenCfgIdCfgDigest OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(16))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Configuration Digest."
REFERENCE
"12.12.3.3.3.a.4"
::= { mstpGen 4 }
mstpGenHelloTime OBJECT-TYPE
SYNTAX Timeout (1..10)
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { mstpGen 5 }
mstpGenMaxAge OBJECT-TYPE
SYNTAX Timeout (6..40)
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { mstpGen 6 }
mstpGenForwardDelay OBJECT-TYPE
SYNTAX Timeout (4..30)
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= {mstpGen 7}
mstpGenMaxHops OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-write
STATUS mandatory
DESCRIPTION
"13.22.f)"
::= { mstpGen 8 }
mstpGenCistRootPathCost OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS mandatory
DESCRIPTION
"."
::= { mstpGen 9 }
mstpGenCistRootBrid OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(8))
MAX-ACCESS read-only
STATUS mandatory
DESCRIPTION
"."
::= { mstpGen 10 }
-- MSTP MAP TABLE
mstMapTable OBJECT-TYPE
SYNTAX SEQUENCE OF MstMapEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains one entry for each instance of MSTP."
::= { mstp 20 }
mstMapEntry OBJECT-TYPE
SYNTAX MstMapEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A conceptual row containing the status of the MSTP instance."
INDEX { mstMapIndex }
::= { mstMapTable 1 }
MstMapEntry ::= SEQUENCE {
mstMapIndex MstiOrCistInstanceIndex,
mstMapVlans1k OCTET STRING,
mstMapVlans2k OCTET STRING,
mstMapVlans3k OCTET STRING,
mstMapVlans4k OCTET STRING,
mstMapRowStatus RowStatus
}
mstMapIndex OBJECT-TYPE
SYNTAX MstiOrCistInstanceIndex
MAX-ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Uniquely identifies an instance. The entry of this table with index 0
presents always, represents CIST. When SET operation "
::= { mstMapEntry 1 }
mstMapVlans1k OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..128))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A string of octets containing one bit per VLAN. The
first octet corresponds to VLANs with VlanIndex values
1 through 8; the second octet to VLANs 9 through
16 etc. The most significant bit of each octet
corresponds to the lowest VlanIndex value in that octet.
For each VLAN that is mapped to this MSTP instance,
the bit corresponding to that VLAN is set to '1'.
Empty (zero) most significant octes are not mandatory."
::= { mstMapEntry 2 }
mstMapVlans2k OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..128))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A string of octets containing one bit per VLAN for
VLANS with VlanIndex values 1024 through 2047. The
first octet corresponds to VLANs with VlanIndex values
1024 through 1031; the second octet to VLANs 1032
through 1039 etc. The most significant bit of each
octet corresponds to the lowest VlanIndex value in that
octet.
For each VLAN that is mapped to this MSTP instance,
the bit corresponding to that VLAN is set to '1'.
Empty (zero) most significant octes are not mandatory."
::= { mstMapEntry 3 }
mstMapVlans3k OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..128))
ACCESS read-write
STATUS current
DESCRIPTION
"A string of octets containing one bit per VLAN for
VLANS with VlanIndex values 2048 through 3071. The
first octet corresponds to VLANs with VlanIndex values
of 2048 through 2055; the second octet to VLANs 2056
through 2063 etc. The most significant bit of each
octet corresponds to the lowest VlanIndex value in that
octet.
For each VLAN that is mapped to this MSTP instance,
the bit corresponding to that VLAN is set to '1'.
Empty (zero) most significant octes are not mandatory."
::= { mstMapEntry 4 }
mstMapVlans4k OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..128))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A string of octets containing one bit per VLAN for
VLANS with VlanIndex values 3072 through 4095. The
first octet corresponds to VLANs with VlanIndex values
3072 through 3079; the second octet to VLANs 3080
through 3087 etc. The most significant bit of each
octet corresponds to the lowest VlanIndex value in that
octet.
For each VLAN that is mapped to this MSTP instance,
the bit corresponding to that VLAN is set to '1'.
Empty (zero) most significant octes are not mandatory."
::= { mstMapEntry 5 }
mstMapRowStatus OBJECT-TYPE
SYNTAX RowStatus
ACCESS read-create
STATUS mandatory
DESCRIPTION
""
::= { mstMapEntry 6 }
-- MSTP Vlan Table, map vlan to msti
mstVlanTable OBJECT-TYPE
SYNTAX SEQUENCE OF MstVlanEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains one entry for each VlanId."
::= { mstp 30 }
mstVlanEntry OBJECT-TYPE
SYNTAX MstVlanEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Information regarding the instance to which each Vlan is mapped."
INDEX { mstVlanIndex }
::= { mstVlanTable 1 }
MstVlanEntry ::= SEQUENCE {
mstVlanIndex INTEGER,
mstVlanMstIndex MstiOrCistInstanceIndex
}
mstVlanIndex OBJECT-TYPE
SYNTAX INTEGER(1..4094)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The VlanId for which this entry contains the instance mapped."
::= { mstVlanEntry 1 }
mstVlanMstIndex OBJECT-TYPE
SYNTAX MstiOrCistInstanceIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"An integer with values ranging from 0 to 64 that identify a
the CIST/MSTI instance to which this VLAN is mapped"
::= { mstVlanEntry 2 }
-- MSTP Port Table, information for all instance of a port
mstpPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF MstpPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table that contains generic information about
every port that is associated with this bridge."
::= { mstp 40 }
mstpPortEntry OBJECT-TYPE
SYNTAX MstpPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of information for each port of the
bridge."
INDEX { mstpPortIndex }
::= { mstpPortTable 1 }
MstpPortEntry ::= SEQUENCE {
mstpPortIndex INTEGER,
mstpPortOperEdgePort TruthValue,
mstpPortOperPointToPointMAC TruthValue
}
mstpPortIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A unique value, greater than zero, for each Port.
The value for each interface sub-layer
must remain constant at least from one re-initialization
of the entity's network management system to the next re-
initialization."
::= { mstpPortEntry 1 }
mstpPortOperEdgePort OBJECT-TYPE
SYNTAX TruthValue
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
REFERENCE ""
::= { mstpPortEntry 2 }
mstpPortOperPointToPointMAC OBJECT-TYPE
SYNTAX TruthValue
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
REFERENCE ""
::= {mstpPortEntry 3}
-- MSTP Xst Table, Cist/Mst status/setting
mstpXstTable OBJECT-TYPE
SYNTAX SEQUENCE OF MstpXstEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"."
::= { mstp 50 }
mstpXstEntry OBJECT-TYPE
SYNTAX MstpXstEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"."
INDEX { mstpXstId }
::= { mstpXstTable 1 }
MstpXstEntry ::= SEQUENCE {
mstpXstId MstiOrCistInstanceIndex,
mstpXstBridgePriority Integer32,
mstpXstBridgeId BridgeId,
mstpXstInternalRootCost Integer32,
mstpXstRootPort INTEGER,
mstpXstTimeSinceTopologyChange TimeTicks,
mstpXstTopologyChangesCount Counter32
}
mstpXstId OBJECT-TYPE
SYNTAX MstiOrCistInstanceIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"0 means CIST."
::= { mstpXstEntry 1 }
mstpXstBridgePriority OBJECT-TYPE
SYNTAX Integer32 (0..61440)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Bridge priority, in steps of 4096."
DEFVAL { 32768 }
::= { mstpXstEntry 2 }
mstpXstBridgeId OBJECT-TYPE
SYNTAX BridgeId
ACCESS read-only
STATUS mandatory
DESCRIPTION
"."
::= { mstpXstEntry 3 }
mstpXstInternalRootCost OBJECT-TYPE
SYNTAX Integer32
ACCESS read-only
STATUS mandatory
DESCRIPTION
"."
::= { mstpXstEntry 4 }
mstpXstRootPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"."
::= { mstpXstEntry 5 }
mstpXstTimeSinceTopologyChange OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"."
::= { mstpXstEntry 6 }
mstpXstTopologyChangesCount OBJECT-TYPE
SYNTAX Counter32
ACCESS read-only
STATUS mandatory
DESCRIPTION
"."
::= { mstpXstEntry 7 }
-- MSTP Xst Port Table, Cist/Mst Port status/setting
mstpXstPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF MstpXstPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"."
::= { mstp 60 }
mstpXstPortEntry OBJECT-TYPE
SYNTAX MstpXstPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"."
REFERENCE
"."
INDEX { mstpXstPortXstId, mstpXstPortIndex }
::= { mstpXstPortTable 1 }
MstpXstPortEntry ::=
SEQUENCE {
mstpXstPortXstId MstiOrCistInstanceIndex,
mstpXstPortIndex INTEGER,
mstpXstPortEnable EnabledStatus,
mstpXstPortPriority Integer32,
mstpXstPortPathCost INTEGER,
mstpXstPortState INTEGER,
mstpXstPortDesignatedRoot BridgeId,
mstpXstPortDesignatedCost Integer32,
mstpXstPortDesignatedBridge BridgeId,
mstpXstPortDesignatedPort INTEGER
}
mstpXstPortXstId OBJECT-TYPE
SYNTAX MstiOrCistInstanceIndex
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"0 means CIST."
::= { mstpXstPortEntry 1 }
mstpXstPortIndex OBJECT-TYPE
SYNTAX INTEGER(1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of mstpPortIndex of the Port
in mstpPortTable."
::= { mstpXstPortEntry 2 }
mstpXstPortEnable OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"."
::= { mstpXstPortEntry 3 }
mstpXstPortPriority OBJECT-TYPE
SYNTAX Integer32 (0..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Port priority, in steps of 16."
DEFVAL { 128 }
::= { mstpXstPortEntry 4 }
mstpXstPortPathCost OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"."
::= { mstpXstPortEntry 5 }
mstpXstPortState OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
discarding(1),
learning(2),
forwarding(3),
unknown(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"."
::= { mstpXstPortEntry 6 }
mstpXstPortDesignatedRoot OBJECT-TYPE
SYNTAX BridgeId
ACCESS read-only
STATUS mandatory
DESCRIPTION
"."
::= { mstpXstPortEntry 7 }
mstpXstPortDesignatedCost OBJECT-TYPE
SYNTAX Integer32
ACCESS read-only
STATUS mandatory
DESCRIPTION
"."
::= { mstpXstPortEntry 8 }
mstpXstPortDesignatedBridge OBJECT-TYPE
SYNTAX BridgeId
ACCESS read-only
STATUS mandatory
DESCRIPTION
"."
::= { mstpXstPortEntry 9 }
mstpXstPortDesignatedPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"."
::= { mstpXstPortEntry 10 }
--MSTP Traps
mstpNotifications OBJECT IDENTIFIER ::= { mstp 70 }
newRoot NOTIFICATION-TYPE
OBJECTS {
mstpXstId
}
STATUS current
DESCRIPTION
""
::= { mstpNotifications 1 }
topologyChange NOTIFICATION-TYPE
OBJECTS {
mstpXstId
}
STATUS current
DESCRIPTION
""
::= { mstpNotifications 2 }
---------------------------------------------------
--
-- Port Isolation
--
---------------------------------------------------
-- portIsolationTable
portIsolationSetup OBJECT IDENTIFIER ::= { mgs3712 112 }
portIsolationTable OBJECT-TYPE
SYNTAX SEQUENCE OF PortIsolationEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { portIsolationSetup 1 }
portIsolationEntry OBJECT-TYPE
SYNTAX PortIsolationEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in portIsolationTable."
INDEX { dot1dBasePort }
::= { portIsolationTable 1 }
PortIsolationEntry ::=
SEQUENCE {
portIsolationState EnabledStatus
}
portIsolationState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Port isolation enabled/disabled on the port.
Enable(1) to be isolated and not exchange packets."
::= { portIsolationEntry 1 }
---------------------------------------------------
--
-- Layer 2 Protocol Tunneling
--
---------------------------------------------------
l2ptSetup OBJECT IDENTIFIER ::= { mgs3712 115 }
-- l2ptState
l2ptState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"L2PT feature enabled/disabled for the switch"
::= { l2ptSetup 1 }
l2ptMacAddr OBJECT-TYPE
SYNTAX MacAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"L2PT destination mac address"
::= { l2ptSetup 2 }
-- l2ptTable
l2ptTable OBJECT-TYPE
SYNTAX SEQUENCE OF L2ptEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { l2ptSetup 3 }
l2ptEntry OBJECT-TYPE
SYNTAX L2ptEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in l2ptTable."
INDEX { dot1dBasePort }
::= { l2ptTable 1 }
L2ptEntry ::=
SEQUENCE {
l2ptProtocolGroup BITS,
l2ptPointToPointProtocolGroup BITS,
l2ptMode INTEGER
}
l2ptProtocolGroup OBJECT-TYPE
SYNTAX BITS {
cdp(0),
stp(1),
vtp(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"L2PT protocols enabled/disabled on the port"
::= { l2ptEntry 1 }
l2ptPointToPointProtocolGroup OBJECT-TYPE
SYNTAX BITS {
pagp(0),
lacp(1),
udld(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"L2PT point-to-point protocols enabled/disabled on the port"
::= { l2ptEntry 2 }
l2ptMode OBJECT-TYPE
SYNTAX INTEGER {
access(1),
tunnel(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"L2PT port role on the port"
::= { l2ptEntry 3 }
---------------------------------------------------
--
-- vlan mapping
--
---------------------------------------------------
-- vlanMappingSetup
vlanMappingSetup OBJECT IDENTIFIER ::= { mgs3712 116 }
vlanMappingState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { vlanMappingSetup 1 }
-- vlanMappingPortTable
vlanMappingPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF VlanMappingPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { vlanMappingSetup 2 }
vlanMappingPortEntry OBJECT-TYPE
SYNTAX VlanMappingPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in vlanMappingPortTable."
INDEX { dot1dBasePort }
::= { vlanMappingPortTable 1 }
VlanMappingPortEntry ::=
SEQUENCE {
vlanMappingPortState EnabledStatus
}
vlanMappingPortState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { vlanMappingPortEntry 1 }
-- vlanMappingRuleTable
vlanMappingRuleTable OBJECT-TYPE
SYNTAX SEQUENCE OF VlanMappingRuleEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { vlanMappingSetup 3 }
vlanMappingRuleEntry OBJECT-TYPE
SYNTAX VlanMappingRuleEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in vlan-mapping rule table"
INDEX { vlanMappingRulePort, vlanMappingRuleVid }
::= { vlanMappingRuleTable 1 }
VlanMappingRuleEntry ::=
SEQUENCE {
vlanMappingRuleName DisplayString,
vlanMappingRulePort INTEGER,
vlanMappingRuleVid INTEGER,
vlanMappingRuleTransVid INTEGER,
vlanMappingRulePriority INTEGER,
vlanMappingRuleRowStatus RowStatus
}
vlanMappingRuleName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The name of vlan-mapping entry"
::= { vlanMappingRuleEntry 1 }
vlanMappingRulePort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"interface port id"
::= { vlanMappingRuleEntry 2 }
vlanMappingRuleVid OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"inner vid"
::= { vlanMappingRuleEntry 3 }
vlanMappingRuleTransVid OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"translated vid"
::= { vlanMappingRuleEntry 4 }
vlanMappingRulePriority OBJECT-TYPE
SYNTAX INTEGER {
prioriry-0(0),
prioriry-1(1),
prioriry-2(2),
prioriry-3(3),
prioriry-4(4),
prioriry-5(5),
prioriry-6(6),
prioriry-7(7)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"priority"
::= { vlanMappingRuleEntry 5 }
vlanMappingRuleRowStatus OBJECT-TYPE
SYNTAX RowStatus
ACCESS read-create
STATUS mandatory
DESCRIPTION
""
::= { vlanMappingRuleEntry 6 }
-- transceiverInfoTable
transceiverInfo OBJECT IDENTIFIER ::= { mgs3712 117 }
-- transceiverSerialInfoTable
transceiverSerialInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF TransceiverSerialInfoEntry
ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { transceiverInfo 1 }
transceiverSerialInfoEntry OBJECT-TYPE
SYNTAX TransceiverSerialInfoEntry
ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in transceiverSerialInfoTable."
INDEX { transceiverSerialInfoEntryPort }
::= { transceiverSerialInfoTable 1 }
TransceiverSerialInfoEntry ::=
SEQUENCE {
transceiverSerialInfoEntryPort INTEGER,
transceiverSerialInfoEntryStatus INTEGER,
transceiverSerialInfoEntryVendor DisplayString,
transceiverSerialInfoEntryPartNo DisplayString,
transceiverSerialInfoEntrySerialNo DisplayString,
transceiverSerialInfoEntryRevision DisplayString,
transceiverSerialInfoEntryDateCode DisplayString,
transceiverSerialInfoEntryTransceiver DisplayString
}
transceiverSerialInfoEntryPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
"Index of transceiverSerialInfo. It is referred to dot1dBasePort"
::= { transceiverSerialInfoEntry 1 }
transceiverSerialInfoEntryStatus OBJECT-TYPE
SYNTAX INTEGER {
ok_with_DDM(1),
ok_without_DDM(2),
nonoperational(3)
}
ACCESS read-only
STATUS current
DESCRIPTION
"Transceiver module status."
::= { transceiverSerialInfoEntry 2 }
transceiverSerialInfoEntryVendor OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS current
DESCRIPTION
"Transceiver module vendor name."
::= { transceiverSerialInfoEntry 3 }
transceiverSerialInfoEntryPartNo OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS current
DESCRIPTION
"Part number provided by transceiver module vendor."
::= { transceiverSerialInfoEntry 4 }
transceiverSerialInfoEntrySerialNo OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS current
DESCRIPTION
"Serial number provided by transceiver module vendor."
::= { transceiverSerialInfoEntry 5 }
transceiverSerialInfoEntryRevision OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS current
DESCRIPTION
"Revision level for part number provided by transceiver module vendor."
::= { transceiverSerialInfoEntry 6 }
transceiverSerialInfoEntryDateCode OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS current
DESCRIPTION
"Transceiver module vendor's manufacturing date code"
::= { transceiverSerialInfoEntry 7 }
transceiverSerialInfoEntryTransceiver OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS current
DESCRIPTION
"Transceiver module type names"
::= { transceiverSerialInfoEntry 8 }
-- transceiverDdmInfoTable
transceiverDdmInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF TransceiverDdmInfoEntry
ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { transceiverInfo 2 }
transceiverDdmInfoEntry OBJECT-TYPE
SYNTAX TransceiverDdmInfoEntry
ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in transceiverDdmInfoTable."
INDEX { transceiverDdmInfoEntryPort, transceiverDdmInfoEntryType }
::= { transceiverDdmInfoTable 1 }
TransceiverDdmInfoEntry ::=
SEQUENCE {
transceiverDdmInfoEntryPort INTEGER,
transceiverDdmInfoEntryType INTEGER,
transceiverDdmInfoEntryAlarmMax INTEGER,
transceiverDdmInfoEntryAlarmMin INTEGER,
transceiverDdmInfoEntryWarnMax INTEGER,
transceiverDdmInfoEntryWarnMin INTEGER,
transceiverDdmInfoEntryCurrent INTEGER,
transceiverDdmInfoEntryDescription DisplayString
}
transceiverDdmInfoEntryPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
"Index of transceiverDdmInfo. This will be referred to dot1dBasePort"
::= { transceiverDdmInfoEntry 1 }
transceiverDdmInfoEntryType OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
"Transceiver module status."
::= { transceiverDdmInfoEntry 2 }
transceiverDdmInfoEntryAlarmMax OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
"Transceiver module vendor name."
::= { transceiverDdmInfoEntry 3 }
transceiverDdmInfoEntryAlarmMin OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
"Part number provided by transceiver module vendor."
::= { transceiverDdmInfoEntry 4 }
transceiverDdmInfoEntryWarnMax OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
"Serial number provided by transceiver module vendor."
::= { transceiverDdmInfoEntry 5 }
transceiverDdmInfoEntryWarnMin OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
"Revision level for part number provided by transceiver module vendor."
::= { transceiverDdmInfoEntry 6 }
transceiverDdmInfoEntryCurrent OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
"Transceiver module vendor's manufacturing date code"
::= { transceiverDdmInfoEntry 7 }
transceiverDdmInfoEntryDescription OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS current
DESCRIPTION
"Transceiver module type names"
::= { transceiverDdmInfoEntry 8 }
-- dot3OamSetup
dot3OamSetup OBJECT IDENTIFIER ::= { mgs3712 118 }
dot3OamState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { dot3OamSetup 1 }
-- dot3OamPortTable
dot3OamPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dot3OamPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { dot3OamSetup 2 }
dot3OamPortEntry OBJECT-TYPE
SYNTAX Dot3OamPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in dot3OamPortTable."
INDEX { ifIndex }
::= { dot3OamPortTable 1 }
Dot3OamPortEntry ::=
SEQUENCE {
dot3OamFunctionsSupported BITS
}
dot3OamFunctionsSupported OBJECT-TYPE
SYNTAX BITS {
unidirectionalSupport (0),
loopbackSupport(1),
eventSupport(2),
variableSupport(3)
}
MAX-ACCESS read-write
STATUS mandatory
DESCRIPTION
"The OAM functions supported on this Ethernet-like interface.
OAM consists of separate functional sets beyond the basic
discovery process that is always required. These functional
groups can be supported independently by any implementation.
These values are communicated to the peer via the local
configuration field of Information OAMPDUs.
Setting 'unidirectionalSupport(0)' indicates that the OA
entity supports the transmission of OAMPDUs on links that are
operating in unidirectional mode (traffic flowing in one
direction only). Setting 'loopbackSupport(1)' indicates that
the OAM entity can initiate and respond to loopback commands.
Setting 'eventSupport(2)' indicates that the OAM entity can
send and receive Event Notification OAMPDUs. Setting
'variableSupport(3)' indicates that the OAM entity can send
and receive Variable Request and Response OAMPDUs.
"
REFERENCE "[802.3ah], 30.3.6.1.6"
::= { dot3OamPortEntry 1 }
-- dot1agCfmMib
dot1agCfmSetup OBJECT IDENTIFIER ::= { mgs3712 119 }
dot1agCfmMIBObjects OBJECT IDENTIFIER ::= { dot1agCfmSetup 1 }
-- ******************************************************************
-- Groups in the CFM MIB Module
-- ******************************************************************
dot1agCfmMep OBJECT IDENTIFIER ::= { dot1agCfmMIBObjects 7 }
-- ******************************************************************
-- The MEP Table
-- ******************************************************************
dot1agCfmMepTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dot1agCfmMepEntry
MAX-ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { dot1agCfmMep 1 }
dot1agCfmMepEntry OBJECT-TYPE
SYNTAX Dot1agCfmMepEntry
MAX-ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The dot1agCfmMep table entry"
INDEX { dot1agCfmMdIndex,
dot1agCfmMaIndex,
dot1agCfmMepIdentifier
}
::= { dot1agCfmMepTable 1 }
Dot1agCfmMepEntry ::= SEQUENCE {
dot1agCfmMepTransmitLbmDataTlvSize Unsigned32
}
dot1agCfmMepTransmitLbmDataTlvSize OBJECT-TYPE
SYNTAX Unsigned32 (0..1500)
MAX-ACCESS read-write
STATUS mandatory
DESCRIPTION
"Size of data to be included in the LBM Data TLV"
REFERENCE
""
::= { dot1agCfmMepEntry 1 }
END