summaryrefslogtreecommitdiff
path: root/MIBS/accedian/ACD-REGULATOR-MIB
diff options
context:
space:
mode:
authorDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
committerDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
commit98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch)
tree9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/accedian/ACD-REGULATOR-MIB
downloadmibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.tar.gz
mibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.zip
Initial commitHEADmain
Diffstat (limited to 'MIBS/accedian/ACD-REGULATOR-MIB')
-rw-r--r--MIBS/accedian/ACD-REGULATOR-MIB802
1 files changed, 802 insertions, 0 deletions
diff --git a/MIBS/accedian/ACD-REGULATOR-MIB b/MIBS/accedian/ACD-REGULATOR-MIB
new file mode 100644
index 0000000..9bb8b04
--- /dev/null
+++ b/MIBS/accedian/ACD-REGULATOR-MIB
@@ -0,0 +1,802 @@
+--
+-- Accedian Enterprise Specific MIB
+--
+-- Copyright (c) 2005-2011, Accedian Networks, Inc.
+-- All rights reserved.
+--
+-- The contents of this document are subject to change without notice.
+--
+
+
+ACD-REGULATOR-MIB DEFINITIONS ::= BEGIN
+
+IMPORTS
+ MODULE-IDENTITY, OBJECT-TYPE,
+ Gauge32, Counter32, Counter64, Unsigned32
+ FROM SNMPv2-SMI
+ DisplayString, TruthValue, DateAndTime, RowStatus
+ FROM SNMPv2-TC
+ MODULE-COMPLIANCE, OBJECT-GROUP
+ FROM SNMPv2-CONF
+ acdMibs
+ FROM ACCEDIAN-SMI;
+
+acdRegulator MODULE-IDENTITY
+
+ LAST-UPDATED "201110100100Z"
+ ORGANIZATION "Accedian Networks, Inc."
+ CONTACT-INFO
+ "Accedian Technical Assistance Center
+ Accedian Networks, Inc.
+ 4878 Levy, suite 202
+ Saint-Laurent, Quebec Canada H4R 2P1
+ E-mail: support@accedian.com"
+ DESCRIPTION
+ "The Regulators database for this Accedian Networks device."
+
+ REVISION "201110100100Z" -- 10 October 2011
+ DESCRIPTION
+ "Add acdRegulatorTableLastChangeTid."
+
+ REVISION "201011100100Z" -- 10 November 2010
+ DESCRIPTION
+ "Add compliance section."
+
+ REVISION "200805010100Z" -- 1 May 2008
+ DESCRIPTION
+ "Add RowStatus in acdRegulatorTable table."
+
+ REVISION "200802060100Z" -- 6 Feb 2008
+ DESCRIPTION
+ "Add support for history table."
+
+ REVISION "200703280100Z" -- 28 March 2007
+ DESCRIPTION
+ "Initial version of MIB module ACD-REGULATOR-MIB."
+
+ ::= { acdMibs 6 }
+
+acdRegulatorNotifications OBJECT IDENTIFIER ::= { acdRegulator 4 }
+acdRegulatorMIBObjects OBJECT IDENTIFIER ::= { acdRegulator 5 }
+acdRegulatorConformance OBJECT IDENTIFIER ::= { acdRegulator 6 }
+
+acdRegulatorTableTid OBJECT IDENTIFIER ::= { acdRegulatorMIBObjects 1 }
+
+-----------------------------------------------------------------------
+ -- The Regulators table
+ -- This table contains all Regulators.
+---------------------------------------------------------------------------
+
+acdRegulatorTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AcdRegulatorEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of all Regulators"
+ ::= { acdRegulator 1 }
+
+acdRegulatorEntry OBJECT-TYPE
+ SYNTAX AcdRegulatorEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A Regulator is a two rates three colors engine to regulate a
+ given traffic."
+ INDEX { acdRegulatorID }
+ ::= { acdRegulatorTable 1 }
+
+
+AcdRegulatorEntry ::= SEQUENCE {
+ acdRegulatorID Unsigned32,
+ acdRegulatorName DisplayString,
+ acdRegulatorCir Unsigned32,
+ acdRegulatorCbs Unsigned32,
+ acdRegulatorEir Unsigned32,
+ acdRegulatorEbs Unsigned32,
+ acdRegulatorIsBlind TruthValue,
+ acdRegulatorIsCouple TruthValue,
+ acdRegulatorRowStatus RowStatus
+
+}
+
+acdRegulatorID OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Unique value for each regulator entry. Its value ranges from 1 to
+ MAXINT (4 bytes). "
+ ::= { acdRegulatorEntry 1 }
+
+acdRegulatorName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (1..31))
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This is a string to identify the regulator."
+ ::= { acdRegulatorEntry 2 }
+
+acdRegulatorCir OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "Kbps"
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The committed information rate."
+ DEFVAL { 20000 }
+ ::= { acdRegulatorEntry 3 }
+
+acdRegulatorCbs OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "Kbytes"
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The committed burst size."
+ DEFVAL { 8 }
+ ::= { acdRegulatorEntry 4 }
+
+acdRegulatorEir OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "Kbps"
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The excess information rate."
+ DEFVAL { 1000 }
+ ::= { acdRegulatorEntry 5 }
+
+acdRegulatorEbs OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "Kbytes"
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The excess burst size."
+ DEFVAL { 8 }
+ ::= { acdRegulatorEntry 6 }
+
+acdRegulatorIsBlind OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Enable or disable the pre-marking color processing."
+ DEFVAL { false }
+ ::= { acdRegulatorEntry 7 }
+
+acdRegulatorIsCouple OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Enable or disable the coupling flag in this regulator."
+ DEFVAL { false }
+ ::= { acdRegulatorEntry 8 }
+
+acdRegulatorRowStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "All columns must have a valid value before a row can be activated. To
+ create a new regulator you shall provide the a unique name for
+ an empty row with the RowStatus set to Create and Go. To delete the
+ row you need to set the RowStatus to destroy."
+ ::= { acdRegulatorEntry 9 }
+
+---------------------------------------------------------------------------
+ -- The Regulator Counters table
+ -- This table contains all counters associated with each regulator.
+---------------------------------------------------------------------------
+
+acdRegulatorStatsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AcdRegulatorStatsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of all counters associated with each regulator."
+ ::= { acdRegulator 2 }
+
+acdRegulatorStatsEntry OBJECT-TYPE
+ SYNTAX AcdRegulatorStatsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An Entry consists of statitics related to a regulator entry."
+ INDEX { acdRegulatorStatsID }
+ ::= { acdRegulatorStatsTable 1 }
+
+
+AcdRegulatorStatsEntry ::= SEQUENCE {
+ acdRegulatorStatsID Unsigned32,
+ acdRegulatorStatsAcceptOctets Counter32,
+ acdRegulatorStatsAcceptOverflowOctets Counter32,
+ acdRegulatorStatsAcceptHCOctets Counter64,
+ acdRegulatorStatsAcceptPkts Counter32,
+ acdRegulatorStatsAcceptOverflowPkts Counter32,
+ acdRegulatorStatsAcceptHCPkts Counter64,
+ acdRegulatorStatsAcceptRate Gauge32,
+ acdRegulatorStatsDropOctets Counter32,
+ acdRegulatorStatsDropOverflowOctets Counter32,
+ acdRegulatorStatsDropHCOctets Counter64,
+ acdRegulatorStatsDropPkts Counter32,
+ acdRegulatorStatsDropOverflowPkts Counter32,
+ acdRegulatorStatsDropHCPkts Counter64,
+ acdRegulatorStatsDropRate Gauge32
+}
+
+acdRegulatorStatsID OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Unique value for each regulator entry. Its value ranges from 1 to
+ MAXINT (4 bytes)."
+ ::= { acdRegulatorStatsEntry 1 }
+
+acdRegulatorStatsAcceptOctets OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "Octets"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of octets received by this regulator. This is a
+ 32 bits counter. Combined with acdRegulatorStatsAcceptOverflowOctets,
+ it provides the equivalent of the 64 bits counter
+ acdRegulatorStatsAcceptHCOctets."
+ ::= { acdRegulatorStatsEntry 2 }
+
+acdRegulatorStatsAcceptOverflowOctets OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "Octets"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of times the associated acdRegulatorStatsAcceptOctets
+ counter has overflowed. This is a 32 bits counter. Combined with
+ acdRegulatorStatsAcceptOctets, it provides the equivalent of the
+ 64 bits counter acdRegulatorStatsAccpetHCOctets."
+ ::= { acdRegulatorStatsEntry 3 }
+
+acdRegulatorStatsAcceptHCOctets OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "Octets"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of octets received by this regulator."
+ ::= { acdRegulatorStatsEntry 4 }
+
+acdRegulatorStatsAcceptPkts OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "Packets"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of packets received by this regulator. This is a
+ 32 bits counter. Combined with acdRegulatorStatsAcceptOverflowPkts,
+ it provides the equivalent of the 64 bits counter
+ acdRegulatorStatsAcceptHCPkts."
+ ::= { acdRegulatorStatsEntry 5 }
+
+acdRegulatorStatsAcceptOverflowPkts OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "Packets"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of times the associated acdRegulatorStatsAcceptPkts
+ counter has overflowed. This is a 32 bits counter. Combined with
+ acdRegulatorStatsAcceptPkts, it provides the equivalent of the
+ 64 bits counter acdRegulatorStatsAcceptHCPkts."
+ ::= { acdRegulatorStatsEntry 6 }
+
+acdRegulatorStatsAcceptHCPkts OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "Octets"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of packets received by this regulator."
+ ::= { acdRegulatorStatsEntry 7 }
+
+acdRegulatorStatsAcceptRate OBJECT-TYPE
+ SYNTAX Gauge32
+ UNITS "Kbps"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The accept rate."
+ ::= { acdRegulatorStatsEntry 8 }
+
+acdRegulatorStatsDropOctets OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "Octets"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of octets received by this regulator. This is a
+ 32 bits counter. Combined with acdRegulatorStatsDropOverflowOctets,
+ it provides the equivalent of the 64 bits counter
+ acdRegulatorStatsDropHCOctets."
+ ::= { acdRegulatorStatsEntry 9 }
+
+acdRegulatorStatsDropOverflowOctets OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "Octets"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of times the associated acdRegulatorStatsDropOctets
+ counter has overflowed. This is a 32 bits counter. Combined with
+ acdRegulatorStatsDropOctets, it provides the equivalent of the
+ 64 bits counter acdRegulatorStatsDropHCOctets."
+ ::= { acdRegulatorStatsEntry 10 }
+
+acdRegulatorStatsDropHCOctets OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "Octets"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of octets received by this regulator."
+ ::= { acdRegulatorStatsEntry 11 }
+
+acdRegulatorStatsDropPkts OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "Packets"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of packets received by this regulator. This is a
+ 32 bits counter. Combined with acdRegulatorStatsDropOverflowPkts,
+ it provides the equivalent of the 64 bits counter
+ acdRegulatorStatsDropHCPkts."
+ ::= { acdRegulatorStatsEntry 12 }
+
+acdRegulatorStatsDropOverflowPkts OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "Packets"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of times the associated acdRegulatorStatsDropPkts
+ counter has overflowed. This is a 32 bits counter. Combined with
+ acdRegulatorStatsDropPkts, it provides the equivalent of the
+ 64 bits counter acdRegulatorStatsDropHCPkts."
+ ::= { acdRegulatorStatsEntry 13 }
+
+acdRegulatorStatsDropHCPkts OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "Octets"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of packets received by this regulator."
+ ::= { acdRegulatorStatsEntry 14 }
+
+acdRegulatorStatsDropRate OBJECT-TYPE
+ SYNTAX Gauge32
+ UNITS "Kbps"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The drop rate."
+ ::= { acdRegulatorStatsEntry 15 }
+
+---------------------------------------------------------------------------
+ -- The Regulator History group
+
+ -- The Regulator History group records periodic statistical samples
+ -- from a regulator and stores them for later retrieval.
+
+---------------------------------------------------------------------------
+
+acdRegulatorHistStatsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AcdRegulatorHistStatsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of all counters associated with each regulator."
+ ::= { acdRegulator 3 }
+
+acdRegulatorHistStatsEntry OBJECT-TYPE
+ SYNTAX AcdRegulatorHistStatsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An Entry consists of statitics related to a regulator entry."
+ INDEX { acdRegulatorHistStatsID , acdRegulatorHistStatsSampleIndex }
+ ::= { acdRegulatorHistStatsTable 1 }
+
+
+AcdRegulatorHistStatsEntry ::= SEQUENCE {
+ acdRegulatorHistStatsID Unsigned32,
+ acdRegulatorHistStatsSampleIndex Unsigned32,
+ acdRegulatorHistStatsStatus INTEGER,
+ acdRegulatorHistStatsDuration Unsigned32,
+ acdRegulatorHistStatsIntervalEnd DateAndTime,
+ acdRegulatorHistStatsAcceptOctets Counter32,
+ acdRegulatorHistStatsAcceptOverflowOctets Counter32,
+ acdRegulatorHistStatsAcceptHCOctets Counter64,
+ acdRegulatorHistStatsAcceptPkts Counter32,
+ acdRegulatorHistStatsAcceptOverflowPkts Counter32,
+ acdRegulatorHistStatsAcceptHCPkts Counter64,
+ acdRegulatorHistStatsAcceptAvgRate Gauge32,
+ acdRegulatorHistStatsAcceptMinRate Gauge32,
+ acdRegulatorHistStatsAcceptMaxRate Gauge32,
+ acdRegulatorHistStatsDropOctets Counter32,
+ acdRegulatorHistStatsDropOverflowOctets Counter32,
+ acdRegulatorHistStatsDropHCOctets Counter64,
+ acdRegulatorHistStatsDropPkts Counter32,
+ acdRegulatorHistStatsDropOverflowPkts Counter32,
+ acdRegulatorHistStatsDropHCPkts Counter64,
+ acdRegulatorHistStatsDropAvgRate Gauge32,
+ acdRegulatorHistStatsDropMinRate Gauge32,
+ acdRegulatorHistStatsDropMaxRate Gauge32
+}
+
+acdRegulatorHistStatsID OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Unique value for each regulator entry. Its value ranges from 1 to
+ MAXINT (4 bytes)."
+ ::= { acdRegulatorHistStatsEntry 1 }
+
+acdRegulatorHistStatsSampleIndex OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An index that uniquely identifies the particular sample this entry
+ represents among all samples associated with the same regulator
+ instance. This index starts at 1 and increases by one as each new
+ sample."
+ ::= { acdRegulatorHistStatsEntry 2 }
+
+acdRegulatorHistStatsStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ valid(1),
+ invalid(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The status of this acdRegulatorHistStats entry."
+ ::= { acdRegulatorHistStatsEntry 3 }
+
+acdRegulatorHistStatsDuration OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The interval in seconds over which the data is sampled for this entry."
+ ::= { acdRegulatorHistStatsEntry 4 }
+
+acdRegulatorHistStatsIntervalEnd OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This is the time of the end of this entry."
+ ::= { acdRegulatorHistStatsEntry 5 }
+
+acdRegulatorHistStatsAcceptOctets OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "Octets"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of octets received by this regulator during this
+ sampling interval. This is a 32 bits counter. Combined with
+ acdRegulatorHistStatsAcceptOverflowOctets, it provides the equivalent
+ of the 64 bits counter acdRegulatorHistStatsAcceptHCOctets."
+ ::= { acdRegulatorHistStatsEntry 6 }
+
+acdRegulatorHistStatsAcceptOverflowOctets OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "Octets"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of times the associated acdRegulatorHistStatsAcceptOctets
+ counter has overflowed during this sampling interval. This is a
+ 32 bits counter. Combined with acdRegulatorHistStatsAcceptOctets,
+ it provides the equivalent of the 64 bits counter
+ acdRegulatorHistStatsAcceptHCOctets."
+ ::= { acdRegulatorHistStatsEntry 7 }
+
+acdRegulatorHistStatsAcceptHCOctets OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "Octets"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of octets received by this regulator during this
+ sampling interval."
+ ::= { acdRegulatorHistStatsEntry 8 }
+
+acdRegulatorHistStatsAcceptPkts OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "Packets"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of packets received by this regulator during this
+ sampling interval. This is a 32 bits counter. Combined with
+ acdRegulatorHistStatsAcceptOverflowPkts, it provides the equivalent
+ of the 64 bits counter acdRegulatorHistStatsAcceptHCPkts."
+ ::= { acdRegulatorHistStatsEntry 9 }
+
+acdRegulatorHistStatsAcceptOverflowPkts OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "Packets"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of times the associated acdRegulatorHistStatsAcceptPkts
+ counter has overflowed during this sampling interval. This is a
+ 32 bits counter. Combined with acdRegulatorHistStatsAcceptPkts, it
+ provides the equivalent of the 64 bits counter
+ acdRegulatorHistStatsAcceptHCPkts."
+ ::= { acdRegulatorHistStatsEntry 10 }
+
+acdRegulatorHistStatsAcceptHCPkts OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "Octets"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of packets received by this regulator during this
+ sampling interval."
+ ::= { acdRegulatorHistStatsEntry 11 }
+
+acdRegulatorHistStatsAcceptAvgRate OBJECT-TYPE
+ SYNTAX Gauge32
+ UNITS "Kbps"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The average accept rate during this sampling interval."
+ ::= { acdRegulatorHistStatsEntry 12 }
+
+acdRegulatorHistStatsAcceptMinRate OBJECT-TYPE
+ SYNTAX Gauge32
+ UNITS "Kbps"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The minimum accept rate during this sampling interval."
+ ::= { acdRegulatorHistStatsEntry 13 }
+
+acdRegulatorHistStatsAcceptMaxRate OBJECT-TYPE
+ SYNTAX Gauge32
+ UNITS "Kbps"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The maximum accept rate during this sampling interval."
+ ::= { acdRegulatorHistStatsEntry 14 }
+
+acdRegulatorHistStatsDropOctets OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "Octets"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of octets received by this regulator during this
+ sampling interval. This is a 32 bits counter. Combined the overflow,
+ counter it provides the equivalent of the 64 bits counter
+ acdRegulatorHistStatsDropHCOctets."
+ ::= { acdRegulatorHistStatsEntry 15 }
+
+acdRegulatorHistStatsDropOverflowOctets OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "Octets"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of times the associated acdRegulatorHistStatsDropOctets
+ counter has overflowed during this sampling interval. This is a
+ 32 bits counter. Combined with acdRegulatorHistStatsDropOctets, it
+ provides the equivalent of the 64 bits counter
+ acdRegulatorHistStatsDropHCOctets."
+ ::= { acdRegulatorHistStatsEntry 16 }
+
+acdRegulatorHistStatsDropHCOctets OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "Octets"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of octets received by this regulator during this
+ sampling interval."
+ ::= { acdRegulatorHistStatsEntry 17 }
+
+acdRegulatorHistStatsDropPkts OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "Packets"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of packets received by this regulator during this
+ sampling interval. This is a 32 bits counter. Combined with
+ acdRegulatorHistStatsDropOverflowPkts, it provides the equivalent of
+ the 64 bits counter acdRegulatorHistStatsDropHCPkts."
+ ::= { acdRegulatorHistStatsEntry 18 }
+
+acdRegulatorHistStatsDropOverflowPkts OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "Packets"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of times the associated acdRegulatorHistStatsDropPkts
+ counter has overflowed during this sampling interval. This is a
+ 32 bits counter. Combined with acdRegulatorHistStatsDropPkts, it
+ provides the equivalent of the 64 bits counter
+ acdRegulatorHistStatsDropHCPkts."
+ ::= { acdRegulatorHistStatsEntry 19 }
+
+acdRegulatorHistStatsDropHCPkts OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "Octets"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of packets received by this regulator during this
+ sampling interval."
+ ::= { acdRegulatorHistStatsEntry 20 }
+
+acdRegulatorHistStatsDropAvgRate OBJECT-TYPE
+ SYNTAX Gauge32
+ UNITS "Kbps"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The average drop rate during this sampling interval."
+ ::= { acdRegulatorHistStatsEntry 21 }
+
+acdRegulatorHistStatsDropMinRate OBJECT-TYPE
+ SYNTAX Gauge32
+ UNITS "Kbps"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The minimum drop rate during this sampling interval."
+ ::= { acdRegulatorHistStatsEntry 22 }
+
+acdRegulatorHistStatsDropMaxRate OBJECT-TYPE
+ SYNTAX Gauge32
+ UNITS "Kbps"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The maximum drop rate during this sampling interval."
+ ::= { acdRegulatorHistStatsEntry 23 }
+
+---------------------------------------------------------------------------
+ -- Transaction ID Information
+---------------------------------------------------------------------------
+
+acdRegulatorTableLastChangeTid OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This is the transaction ID of the last change of the acdRegulatorTable
+ table. If this value is different since the last read this is indicate
+ a table change."
+ ::= { acdRegulatorTableTid 1 }
+
+---------------------------------------------------------------------------
+ -- ACD-REGULATOR-MIB Module - Conformance Information
+---------------------------------------------------------------------------
+
+acdRegulatorCompliances OBJECT IDENTIFIER ::= { acdRegulatorConformance 1 }
+acdRegulatorGroups OBJECT IDENTIFIER ::= { acdRegulatorConformance 2 }
+
+---------------------------------------------------------------------------
+ -- Units of conformance
+---------------------------------------------------------------------------
+
+acdRegulatorGroup OBJECT-GROUP
+ OBJECTS {
+ acdRegulatorName,
+ acdRegulatorCir,
+ acdRegulatorCbs,
+ acdRegulatorEir,
+ acdRegulatorEbs,
+ acdRegulatorIsBlind,
+ acdRegulatorIsCouple,
+ acdRegulatorRowStatus
+ }
+ STATUS current
+ DESCRIPTION
+ "Objects for the Regulator configurtion Group."
+ ::= { acdRegulatorGroups 1 }
+
+acdRegulatorStatsGroup OBJECT-GROUP
+ OBJECTS {
+ acdRegulatorStatsAcceptOctets,
+ acdRegulatorStatsAcceptOverflowOctets,
+ acdRegulatorStatsAcceptHCOctets,
+ acdRegulatorStatsAcceptPkts,
+ acdRegulatorStatsAcceptOverflowPkts,
+ acdRegulatorStatsAcceptHCPkts,
+ acdRegulatorStatsAcceptRate,
+ acdRegulatorStatsDropOctets,
+ acdRegulatorStatsDropOverflowOctets,
+ acdRegulatorStatsDropHCOctets,
+ acdRegulatorStatsDropPkts,
+ acdRegulatorStatsDropOverflowPkts,
+ acdRegulatorStatsDropHCPkts,
+ acdRegulatorStatsDropRate
+ }
+ STATUS current
+ DESCRIPTION
+ "Objects for the Regulator statistics Group."
+ ::= { acdRegulatorGroups 2 }
+
+acdRegulatorHistStatsGroup OBJECT-GROUP
+ OBJECTS {
+ acdRegulatorHistStatsStatus,
+ acdRegulatorHistStatsDuration,
+ acdRegulatorHistStatsIntervalEnd,
+ acdRegulatorHistStatsAcceptOctets,
+ acdRegulatorHistStatsAcceptOverflowOctets,
+ acdRegulatorHistStatsAcceptHCOctets,
+ acdRegulatorHistStatsAcceptPkts,
+ acdRegulatorHistStatsAcceptOverflowPkts,
+ acdRegulatorHistStatsAcceptHCPkts,
+ acdRegulatorHistStatsAcceptAvgRate,
+ acdRegulatorHistStatsAcceptMinRate,
+ acdRegulatorHistStatsAcceptMaxRate,
+ acdRegulatorHistStatsDropOctets,
+ acdRegulatorHistStatsDropOverflowOctets,
+ acdRegulatorHistStatsDropHCOctets,
+ acdRegulatorHistStatsDropPkts,
+ acdRegulatorHistStatsDropOverflowPkts,
+ acdRegulatorHistStatsDropHCPkts,
+ acdRegulatorHistStatsDropAvgRate,
+ acdRegulatorHistStatsDropMinRate,
+ acdRegulatorHistStatsDropMaxRate
+ }
+ STATUS current
+ DESCRIPTION
+ "Objects for the Regulator history statistics Group."
+ ::= { acdRegulatorGroups 3 }
+
+acdRegulatorTidGroup OBJECT-GROUP
+ OBJECTS {
+ acdRegulatorTableLastChangeTid
+ }
+ STATUS current
+ DESCRIPTION
+ "List of scalars to monitior changes in tables."
+ ::= { acdRegulatorGroups 4 }
+
+acdPaaCompliance MODULE-COMPLIANCE
+ STATUS current
+ DESCRIPTION
+ "The compliance statement for support of the ACD-REGULATOR-MIB module."
+ MODULE
+ MANDATORY-GROUPS {
+ acdRegulatorGroup,
+ acdRegulatorStatsGroup,
+ acdRegulatorHistStatsGroup,
+ acdRegulatorTidGroup
+ }
+
+ OBJECT acdRegulatorRowStatus
+ SYNTAX RowStatus { active(1) }
+ WRITE-SYNTAX RowStatus { createAndGo(4), destroy(6) }
+ DESCRIPTION "Support for createAndWait is not required."
+
+ ::= { acdRegulatorCompliances 1 }
+
+
+END