diff options
| author | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
|---|---|---|
| committer | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
| commit | 98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch) | |
| tree | 9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/adva/F3-FPM-MIB | |
| download | mibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.tar.gz mibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.zip | |
Diffstat (limited to 'MIBS/adva/F3-FPM-MIB')
| -rw-r--r-- | MIBS/adva/F3-FPM-MIB | 6832 |
1 files changed, 6832 insertions, 0 deletions
diff --git a/MIBS/adva/F3-FPM-MIB b/MIBS/adva/F3-FPM-MIB new file mode 100644 index 0000000..0e8bd43 --- /dev/null +++ b/MIBS/adva/F3-FPM-MIB @@ -0,0 +1,6832 @@ +F3-FPM-MIB DEFINITIONS ::= BEGIN + +IMPORTS + MODULE-COMPLIANCE, OBJECT-GROUP + FROM SNMPv2-CONF + MODULE-IDENTITY, OBJECT-TYPE, Integer32, Unsigned32, Counter64 + FROM SNMPv2-SMI + TruthValue, RowStatus, StorageType, + VariablePointer, TEXTUAL-CONVENTION, DisplayString, DateAndTime + FROM SNMPv2-TC + VlanId, AdminState, OperationalState, SecondaryState, + VlanPriority, CmPmIntervalType, PerfCounter64, CmPmBinAction + FROM CM-COMMON-MIB + neIndex, shelfIndex, slotIndex + FROM CM-ENTITY-MIB + cmEthernetAccPortIndex, ShapingType, FlowVlanActionType, + FlowTagControl, PolicerAlgorithmType, PolicerColorMode, + cmMPFlowEntry, CmControlProtocolDispType, CmActiveControlProtocolsType, + cmEthernetNetPortIndex, cmMPFlowIndex + FROM CM-FACILITY-MIB + fsp150cm + FROM ADVA-MIB + ProtectLearningControl, LearningAction, FlowLearningConfigAction + FROM F3-BRIDGE-MIB + FlowSecState + FROM CM-COMMON-MIB; + +f3FpmMIB MODULE-IDENTITY + LAST-UPDATED "201607110000Z" + ORGANIZATION "ADVA Optical Networking" + CONTACT-INFO + " Jakub Nadolski + ADVA Optical Networking, Inc. + Tel: +48 58 7716 421 + E-mail: jnadolski@advaoptical.com + Postal: ul. Slaska 35 + 81-310 Gdynia, Poland" + DESCRIPTION + "This module defines the Flow Point Model MIB definitions + used by the F3 product lines. + Copyright (C) ADVA Optical Networking." + REVISION "201607110000Z" + DESCRIPTION + "Notes from release 201607110000Z + (1) renamed the type FlowSecureState to FlowSecState + Notes from release 201607080000Z + (1) added f3AccFlowpointRefConnectGuardFlowObject, f3AccFlowpointSecureBlockingControl, and + f3AccFlowpointSecureState to f3AccFlowpointTable + (2) added f3NetFlowpointRefConnectGuardFlowObject, f3NetFlowpointSecureBlockingControl, + and f3NetFlowpointSecureState to f3NetFlowpoitTable + (3) added f3MPFlowRefConnectGuardFlowObject and f3MPFlowSecureState to f3MPFlowExtTable + Notes from release 201504210000Z, + (1) Ready for release FSP150CC 8.1." + + ::= {fsp150cm 43} + +-- +-- OID definitions +-- + +f3FpmConfigObjects OBJECT IDENTIFIER ::= {f3FpmMIB 1} +f3FpmPerfObjects OBJECT IDENTIFIER ::= {f3FpmMIB 2} +f3FpmPerfNotifications OBJECT IDENTIFIER ::= {f3FpmMIB 3} +f3FpmConformance OBJECT IDENTIFIER ::= {f3FpmMIB 4} + + +-- +-- Acess Flow Point Table +-- +f3AccFlowPointTable OBJECT-TYPE + SYNTAX SEQUENCE OF F3AccFlowPointEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of entries corresponding to Access Flow Point + for configuration purposes." + ::= { f3FpmConfigObjects 1 } + +f3AccFlowPointEntry OBJECT-TYPE + SYNTAX F3AccFlowPointEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A conceptual row in the f3AccFlowPointTable. + These entries represent an Access Flow Point. + If the Flow Point attached to a lag, the slotIndex should + be 255 (255 is used to identify the Flow Point belongs to lag), + and the cmEthernetAccPortIndex should be the f3LagIndex." + + INDEX { neIndex, shelfIndex, slotIndex, cmEthernetAccPortIndex, f3AccFlowPointIndex } + ::= { f3AccFlowPointTable 1 } + +F3AccFlowPointEntry ::= SEQUENCE { + f3AccFlowPointIndex Integer32, + f3AccFlowPointAlias DisplayString, + + f3AccFlowPointAdminState AdminState, + f3AccFlowPointOperationalState OperationalState, + f3AccFlowPointSecondaryState SecondaryState, + + f3AccFlowPointAssociatedFlowId VariablePointer, + + f3AccFlowPointIngressMultiCOSEnabled TruthValue, + f3AccFlowPointIngressCOS Integer32, + f3AccFlowPointEgressShapingType ShapingType, + + f3AccFlowPointIngressVlanMemberList DisplayString, + f3AccFlowPointVlanMemberAction FlowVlanActionType, + f3AccFlowPointVlanMemberActionVlan DisplayString, + f3AccFlowPointIngressUntaggedFrameEnabled TruthValue, + + f3AccFlowPointCTagControl FlowTagControl, + f3AccFlowPointCTagVlanId VlanId, + f3AccFlowPointCTagVlanPriority VlanPriority, + f3AccFlowPointSTagControl FlowTagControl, + f3AccFlowPointSTagVlanId VlanId, + f3AccFlowPointSTagVlanPriority VlanPriority, + + f3AccFlowPointEgressOuterTagPrioMapEnabled TruthValue, + f3AccFlowPointEgressInnerTagPrioMapEnabled TruthValue, + f3AccFlowPointSESFramesLossThresholdRatio Integer32, + f3AccFlowPointDefaultMemberEnabled TruthValue, + + f3AccFlowPointMcastRateLimitEnabled TruthValue, + f3AccFlowPointMcastRateLimitSpeedLo Unsigned32, + f3AccFlowPointMcastRateLimitSpeedHi Unsigned32, + f3AccFlowPointBcastRateLimitEnabled TruthValue, + f3AccFlowPointBcastRateLimitSpeedLo Unsigned32, + f3AccFlowPointBcastRateLimitSpeedHi Unsigned32, + f3AccFlowPointCombinedRateLimitEnabled TruthValue, + f3AccFlowPointCombinedRateLimitSpeedLo Unsigned32, + f3AccFlowPointCombinedRateLimitSpeedHi Unsigned32, + + f3AccFlowPointSplitHorizonGroupOID VariablePointer, + f3AccFlowPointLoopAvoidance VariablePointer, + f3AccFlowPointHierarchicalCOSEnabled TruthValue, + f3AccFlowPointMaximumBWLo Unsigned32, + f3AccFlowPointMaximumBWHi Unsigned32, + f3AccFlowPointGuaranteedBWLo Unsigned32, + f3AccFlowPointGuaranteedBWHi Unsigned32, + f3AccFlowPointAutoBandwidthConfigEnabled TruthValue, + f3AccFlowPointAutoCIRPercentage Integer32, + f3AccFlowPointFrameFwdEnabled TruthValue, + + f3AccFlowPointStorageType StorageType, + f3AccFlowPointRowStatus RowStatus, + + f3AccFlowPointUsePortPrioMapProfile TruthValue, + f3AccFlowPointRefPrioMapProfile VariablePointer, + f3AccFlowpointRefConnectGuardFlowObject VariablePointer, + f3AccFlowpointSecureBlockingControl TruthValue, + f3AccFlowpointSecureState FlowSecState +} + +f3AccFlowPointIndex OBJECT-TYPE + SYNTAX Integer32 (1..65535) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The integer index value corresponding to an Flow Point." + ::= { f3AccFlowPointEntry 1 } + +f3AccFlowPointAlias OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..64)) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object allows SNMP management entities to provide a + circuit identifier with the Flow Point." + ::= { f3AccFlowPointEntry 2 } + +f3AccFlowPointAdminState OBJECT-TYPE + SYNTAX AdminState + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object represents the Administrative State of the Flow Point." + ::= { f3AccFlowPointEntry 3 } + +f3AccFlowPointOperationalState OBJECT-TYPE + SYNTAX OperationalState + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object represents the Operational State of the Flow Point." + ::= { f3AccFlowPointEntry 4 } + +f3AccFlowPointSecondaryState OBJECT-TYPE + SYNTAX SecondaryState + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object represents the Secondary State of the Flow Point." + ::= { f3AccFlowPointEntry 5 } + +f3AccFlowPointAssociatedFlowId OBJECT-TYPE + SYNTAX VariablePointer + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object provides the association of an Flow with an Flow Point." + ::= { f3AccFlowPointEntry 6 } + +f3AccFlowPointIngressMultiCOSEnabled OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object allows specification of ingress multiple COS + (Class of Service) Flow Point." + ::= { f3AccFlowPointEntry 7 } + +f3AccFlowPointIngressCOS OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-create + STATUS deprecated + DESCRIPTION + "This object allows specification of ingress COS + (Class of Service) Flow Point. + + This attribute has been deprecated and is not supported. The + Ingress COS is determined from the flowpoint's associated + Priority Mapping Profle." + ::= { f3AccFlowPointEntry 8 } + +f3AccFlowPointEgressShapingType OBJECT-TYPE + SYNTAX ShapingType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object allows specification of Shaping Type for Flow Point. + For 8.1.1 release, only flow-based Shaping Type is supported." + ::= { f3AccFlowPointEntry 9 } + +f3AccFlowPointIngressVlanMemberList OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..512)) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "It allows specification of VLAN members of the Flow Point. + VLAN members are comma separated, of the form X-Y where X is the + VLAN Id and Y is the VLAN Priority. VLAN members can be of + the form X-* or X (vlan X with all priorities), *-Y (all vlans + with priority Y), and X1:X2 (range of vlans from X1 to X2, + all priorities). Members with specific VLAN Id and specific + VLAN Priority are not supported. Once the Flow Point is created, + this attribute can only be updated using f3AccFlowPointVlanMemberAction + and f3AccFlowPointVlanMemberActionVlan objects." + ::= { f3AccFlowPointEntry 10 } + +f3AccFlowPointVlanMemberAction OBJECT-TYPE + SYNTAX FlowVlanActionType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object allows to add or remove the VLAN members specified by + f3AccFlowPointVlanMemberActionVlan object. SNMP manager must first + configure the VLAN member to be added/removed in the object + f3AccFlowPointVlanMemberActionVlan and then should specify + f3AccFlowPointVlanMemberAction on whether to add/remove the specified + VLAN member." + ::= { f3AccFlowPointEntry 11 } + +f3AccFlowPointVlanMemberActionVlan OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..16)) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object allows adding/removing VLAN members to a Flow Point. + VLAN member is of the form X-Y where X is the VLAN Id and Y is + the VLAN Priority. VLAN members can be of the form X-* (vlan X + with all priorities), *-Y (all vlans with priority Y), and X1:X2 + (range of vlans from X1 to X2, all priorities). Members with + specific VLAN Id and specific VLAN Priority are not supported. + In order to add/remove VLAN member to a flow, user must specify + this object with appropriate VLAN and then + invoke f3AccFlowPointVlanMemberAction." + ::= { f3AccFlowPointEntry 12 } + +f3AccFlowPointIngressUntaggedFrameEnabled OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object allows to specify whether or not the Flow Point + supports untagged frame." + ::= { f3AccFlowPointEntry 13 } + +f3AccFlowPointCTagControl OBJECT-TYPE + SYNTAX FlowTagControl + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object allows specification of the tag management + operation on the C-TAG. Supported types are 'push', 'pushvid', + 'swaptag', 'swapvid' and 'none'. If the type is 'push', + the VLAN Id (f3AccFlowPointCTagVlanId) and priority + (f3AccFlowPointCTagVlanPriority) are pushed onto the frame; + if the type is 'pushvid', only the VLAN Id (12 bits) is pushed, + the Priority is copied from incoming tag's priority; + if the type is 'swaptag', both VLAN Id and Priority (15 bits) + are swapped with the specified f3AccFlowPointCTagVlanId and + f3AccFlowPointCTagVlanPriority; + if the type is 'swapvid', only the VLAN Id (12 bits) are + swapped with the specified f3AccFlowPointCTagVlanId; + if the type is 'none', no C-TAG management is performed." + ::= { f3AccFlowPointEntry 14 } + +f3AccFlowPointCTagVlanId OBJECT-TYPE + SYNTAX VlanId + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object allows specification of the VLAN Id to + be pushed or swapped, based on the value of + f3AccFlowPointIngressCTagControl. It is applicable + for 'push', 'swaptag', 'swapvid' and 'pushvid' control types." + ::= { f3AccFlowPointEntry 15 } + +f3AccFlowPointCTagVlanPriority OBJECT-TYPE + SYNTAX VlanPriority + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object allows specification of the VLAN Priority to + be pushed or swapped, based on the value of f3AccFlowPointIngressCTagControl. + It is applicable for 'push' and 'swaptag' control types." + ::= { f3AccFlowPointEntry 16 } + +f3AccFlowPointSTagControl OBJECT-TYPE + SYNTAX FlowTagControl + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object allows specification of the tag management + operation on the S-TAG. Supported types are 'push', 'pushvid', + 'swaptag', 'swapvid' and 'none'. If the type is 'push', + the VLAN Id (f3AccFlowPointSTagVlanId) and priority + (f3AccFlowPointSTagVlanPriority) are pushed onto the frame; + if the type is 'pushvid', only the VLAN Id (12 bits) is pushed, + the Priority is copied from incoming tag's priority; + if the type is 'swaptag', both VLAN Id and Priority (15 bits) + are swapped with the specified f3AccFlowPointSTagVlanId and + f3AccFlowPointSTagVlanPriority; + if the type is 'swapvid', only the VLAN Id (12 bits) are + swapped with the specified f3AccFlowPointSTagVlanId; + if the type is 'none', no S-TAG management is performed." + ::= { f3AccFlowPointEntry 17 } + +f3AccFlowPointSTagVlanId OBJECT-TYPE + SYNTAX VlanId + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object allows specification of the VLAN Id to + be pushed or swapped, based on the value of + f3AccFlowPointIngressSTagControl. It is applicable + for 'push', 'swaptag', 'swapvid' and 'pushvid' control types." + ::= { f3AccFlowPointEntry 18 } + +f3AccFlowPointSTagVlanPriority OBJECT-TYPE + SYNTAX VlanPriority + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object allows specification of the VLAN Priority to + be pushed or swapped, based on the value of + f3AccFlowPointIngressSTagControl. It is applicable + for 'push' and 'swaptag' control types." + ::= { f3AccFlowPointEntry 19 } + +f3AccFlowPointEgressOuterTagPrioMapEnabled OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object defines whether to use the Egress Prio + Mapping to swap the priority of outer tag. When Enabled, + it indicates that the operation specified in the + EgressPrioMapTable would be applied to Flow for specified COS. + When Disabled,the EgressPrioMapTable operations are ignored + for specified Flow COS." + ::= { f3AccFlowPointEntry 20 } + +f3AccFlowPointEgressInnerTagPrioMapEnabled OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object defines whether to use the Egress Prio + Mapping to swap the priority of inner tag. When Enabled, + it indicates that the operation specified in the + EgressPrioMapTable would be applied to Flow for specified COS. + When Disabled, the EgressPrioMapTable operations are ignored + for specified Flow COS." + ::= { f3AccFlowPointEntry 21 } + +f3AccFlowPointSESFramesLossThresholdRatio OBJECT-TYPE + SYNTAX Integer32 (0..100) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object is used to specify the frame-loss ratio + per flow that starts counting Severely Errored Seconds (SES) + on the flowpoint. + This functionality is applicable if the flowpoint is monitored + using the Y.1731 ESA functionality." + ::= { f3AccFlowPointEntry 22 } + +f3AccFlowPointDefaultMemberEnabled OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Truth Value means that on this FP, the membership is all the tag + packets without match any other membership associated to the port. + Untagged means untagged flow. Default only care tagged flow." + ::= { f3AccFlowPointEntry 23 } + +f3AccFlowPointMcastRateLimitEnabled OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Whether multicast packets need be limited per FP." + ::= { f3AccFlowPointEntry 24 } + +f3AccFlowPointMcastRateLimitSpeedLo OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The rate limiting for multicast packets per FP. When + f3AccFlowPointMcastRateLimitEnabled and the value is 0, + it means all multicast frame are dropped. This objects + only represents low 32 bits." + ::= { f3AccFlowPointEntry 25 } + +f3AccFlowPointMcastRateLimitSpeedHi OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The rate limiting for multicast packets per FP. When + f3AccFlowPointMcastRateLimitEnabled and the value is 0, + it means all multicast frame are dropped. This objects + only represents high 32 bits." + ::= { f3AccFlowPointEntry 26 } + +f3AccFlowPointBcastRateLimitEnabled OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Whether broadcast packets need be limited per FP." + ::= { f3AccFlowPointEntry 27 } + +f3AccFlowPointBcastRateLimitSpeedLo OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The rate limiting for broadcast packets per FP. When + f3AccFlowPointBcastRateLimitEnabled and the value is 0, + it means all multicast frame are dropped. This objects + only represents low 32 bits." + ::= { f3AccFlowPointEntry 28 } + +f3AccFlowPointBcastRateLimitSpeedHi OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The rate limiting for broadcast packets per FP. When + f3AccFlowPointBcastRateLimitEnabled and the value is 0, + it means all multicast frame are dropped. This objects + only represents high 32 bits." + ::= { f3AccFlowPointEntry 29 } + +f3AccFlowPointCombinedRateLimitEnabled OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Whether broadcast and multicast packets need be limited per FP." + ::= { f3AccFlowPointEntry 30 } + +f3AccFlowPointCombinedRateLimitSpeedLo OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The rate limiting for broadcast and multicast packets per FP. + When f3AccFlowPointCombinedRateLimitEnabled is true and the value is 0, + it means all broadcast and multicast frame are dropped. This object + only represents low 32 bits." + ::= { f3AccFlowPointEntry 31 } + +f3AccFlowPointCombinedRateLimitSpeedHi OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The rate limiting for broadcast and multicast packets per FP. + When f3AccFlowPointCombinedRateLimitEnabled is true and the value is 0, + it means all broadcast and multicast frame are dropped. This object + only represents high 32 bits." + ::= { f3AccFlowPointEntry 32 } + +f3AccFlowPointSplitHorizonGroupOID OBJECT-TYPE + SYNTAX VariablePointer + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Specifies the Split-Horizon Group OID. If there is no SHG, the value is none." + ::= { f3AccFlowPointEntry 33 } + +f3AccFlowPointLoopAvoidance OBJECT-TYPE + SYNTAX VariablePointer + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "EID of this associated Loop Avoidance protocol entity. + A value of NONE indicates there is no loop avoidance protocol. + Currently ERP EID is filled when ELAN service is created." + ::= { f3AccFlowPointEntry 34 } + +f3AccFlowPointHierarchicalCOSEnabled OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Enable or Disable Hierarchical COS shaping (flow shaping)." + ::= { f3AccFlowPointEntry 35 } + +f3AccFlowPointMaximumBWLo OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This attribute description the Flow Point maximum bandwidth. + This object only represents low 32 bits." + ::= { f3AccFlowPointEntry 36 } + +f3AccFlowPointMaximumBWHi OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This attribute description the Flow Point maximum bandwidth. + This object only represents high 32 bits." + ::= { f3AccFlowPointEntry 37 } + +f3AccFlowPointGuaranteedBWLo OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This attribute description the Flow Point guaranteed bandwidth. + This object only represents low 32 bits." + ::= { f3AccFlowPointEntry 38 } + +f3AccFlowPointGuaranteedBWHi OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This attribute description the Flow Point guaranteed bandwidth. + This objects only represents high 32 bits." + ::= { f3AccFlowPointEntry 39 } + +f3AccFlowPointAutoBandwidthConfigEnabled OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object specifies the shaper bandwidth is automatically adjusted + by the system. For a single COS Flow Point, the shaper EIR bandwidth is + set to the maximum port bandwidth; the shaper CIR is set to the available + port bandwidth multiplied by the value of the f3AccFlowPointAutoCIRPercentage + object. For a Hierarchical-COS Flow Point, the f3AccFlowPointMaximumBWLo and + f3AccFlowPointMaximumBWHi are set to the maximum port bandwidth; + the f3AccFlowPointGuaranteedBWLo and f3AccFlowPointGuaranteedBWHi are set to + the available port bandwidth multiplied by the value of the + f3AccFlowPointAutoCIRPercentage object. The value of this object must be FALSE + when f3AccFlowPointIngressMultiCOSEnabled is TRUE and + f3AccFlowPointHierarchicalCOSEnabled is FALSE." + ::= { f3AccFlowPointEntry 40 } + +f3AccFlowPointAutoCIRPercentage OBJECT-TYPE + SYNTAX Integer32 (0..100) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object specifies the percentage of available shaper CIR to be assigned + to this Flow Point when f3AccFlowPointAutoBandwidthConfigEnabled is TRUE." + ::= { f3AccFlowPointEntry 41 } + +f3AccFlowPointFrameFwdEnabled OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "When enabled Flow Point will forward frames it receives. When disabled, + the Flow Point will not forward frames it receives." + ::= { f3AccFlowPointEntry 42 } + +f3AccFlowPointStorageType OBJECT-TYPE + SYNTAX StorageType + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The type of storage configured for this entry." + ::= { f3AccFlowPointEntry 43 } + +f3AccFlowPointRowStatus OBJECT-TYPE + SYNTAX RowStatus + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The status of this row. + An entry MUST NOT exist in the active state unless all + objects in the entry have an appropriate value, as described + in the description clause for each writable object. + + The values of f3AccFlowPointRowStatus supported are + createAndGo(4) and destroy(6). All mandatory attributes + must be specified in a single SNMP SET request with + f3AccFlowPointRowStatus value as createAndGo(4). + Upon successful row creation, this object has a + value of active(1). + + The f3AccFlowPointRowStatus object may be modified if + the associated instance of this object is equal to active(1)." + ::= { f3AccFlowPointEntry 44 } + +f3AccFlowPointUsePortPrioMapProfile OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This indicates whether the flow point is using, if true, the port's + Priority Mapping Profile or, if false, is using its own + Priority Mapping Profile." + ::= { f3AccFlowPointEntry 45 } + +f3AccFlowPointRefPrioMapProfile OBJECT-TYPE + SYNTAX VariablePointer + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object allows to set priority map profile." + ::= { f3AccFlowPointEntry 46 } + +f3AccFlowpointRefConnectGuardFlowObject OBJECT-TYPE + SYNTAX VariablePointer + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object specifies Mac Sec flow object OID." + ::= { f3AccFlowPointEntry 47 } + +f3AccFlowpointSecureBlockingControl OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object can be used to enable/disable secure block." + ::= { f3AccFlowPointEntry 48 } + +f3AccFlowpointSecureState OBJECT-TYPE + SYNTAX FlowSecState + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object specifies the secure state of this flow." + ::= { f3AccFlowPointEntry 49 } + + +-- +-- Access Flow Point QoS Shaper +-- +f3AccFpQosShaperTable OBJECT-TYPE + SYNTAX SEQUENCE OF F3AccFpQosShaperEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of entries corresponding to Access Flow Point + Quality of Service Shaper for configuration purposes." + ::= { f3FpmConfigObjects 2 } + +f3AccFpQosShaperEntry OBJECT-TYPE + SYNTAX F3AccFpQosShaperEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A conceptual row in the f3AccFpQosShaperTable. + These entries represent an Access Flow Point Quality + of Service Shaper." + INDEX { neIndex, shelfIndex, slotIndex, cmEthernetAccPortIndex, + f3AccFlowPointIndex, f3AccFpQosShaperIndex } + ::= { f3AccFpQosShaperTable 1 } + +F3AccFpQosShaperEntry ::= SEQUENCE { + f3AccFpQosShaperIndex Integer32, + + f3AccFpQosShaperAdminState AdminState, + f3AccFpQosShaperOperationalState OperationalState, + f3AccFpQosShaperSecondaryState SecondaryState, + + f3AccFpQosShaperCIRLo Unsigned32, + f3AccFpQosShaperCIRHi Unsigned32, + f3AccFpQosShaperEIRLo Unsigned32, + f3AccFpQosShaperEIRHi Unsigned32, + f3AccFpQosShaperCBS Unsigned32, + f3AccFpQosShaperEBS Unsigned32, + f3AccFpQosShaperBufferSize Unsigned32, + f3AccFpQosShaperCOS Integer32, + + f3AccFpQosShaperStorageType StorageType, + f3AccFpQosShaperRowStatus RowStatus +} + +f3AccFpQosShaperIndex OBJECT-TYPE + SYNTAX Integer32 (1..8) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The unique integer index value corresponding to a Quality + of Service Shaper." + ::= { f3AccFpQosShaperEntry 1 } + +f3AccFpQosShaperAdminState OBJECT-TYPE + SYNTAX AdminState + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object represents the Administrative State of a Shaper." + ::= { f3AccFpQosShaperEntry 2 } + +f3AccFpQosShaperOperationalState OBJECT-TYPE + SYNTAX OperationalState + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object represents the Operational State of a Shaper." + ::= { f3AccFpQosShaperEntry 3 } + +f3AccFpQosShaperSecondaryState OBJECT-TYPE + SYNTAX SecondaryState + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object represents the Secondary State of the Shaper." + ::= { f3AccFpQosShaperEntry 4 } + +f3AccFpQosShaperCIRLo OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object represents the Commited Information Rate (CIR) + (Lower 32 bits) of the Shaper." + ::= { f3AccFpQosShaperEntry 5 } + +f3AccFpQosShaperCIRHi OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object represents the Commited Information Rate (CIR) + (Higher 32 bits) of the Shaper." + ::= { f3AccFpQosShaperEntry 6 } + +f3AccFpQosShaperEIRLo OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object represents the Excess Information Rate (EIR) + (Lower 32 bits) of a Shaper." + ::= { f3AccFpQosShaperEntry 7 } + +f3AccFpQosShaperEIRHi OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object represents the Excess Information Rate (EIR) + (Lower 32 bits) of a Shaper." + ::= { f3AccFpQosShaperEntry 8 } + +f3AccFpQosShaperCBS OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object represents the Commited Burst Size (CBS) + of a Shaper." + ::= { f3AccFpQosShaperEntry 9 } + +f3AccFpQosShaperEBS OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object represents the Excess Burst Size (EBS) + of a Shaper." + ::= { f3AccFpQosShaperEntry 10 } + +f3AccFpQosShaperBufferSize OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object represents the Buffer Size of the Shaper." + ::= { f3AccFpQosShaperEntry 11 } + +f3AccFpQosShaperCOS OBJECT-TYPE + SYNTAX Integer32 (0..7) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object provides the COS (Class of Service) value for + the QOS Shaper." + ::= { f3AccFpQosShaperEntry 12 } + +f3AccFpQosShaperStorageType OBJECT-TYPE + SYNTAX StorageType + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The type of storage configured for this entry." + ::= { f3AccFpQosShaperEntry 13 } + +f3AccFpQosShaperRowStatus OBJECT-TYPE + SYNTAX RowStatus + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The status of this row. + An entry MUST NOT exist in the active state unless all + objects in the entry have an appropriate value, as described + in the description clause for each writable object. + + The values of f3AccFpQosShaperRowStatus supported are + createAndGo(4) and destroy(6). All mandatory attributes + must be specified in a single SNMP SET request with + f3AccFpQosShaperRowStatus value as createAndGo(4). + Upon successful row creation, this object has a + value of active(1). + + The f3AccFpQosShaperRowStatus object may be modified if + the associated instance of this object is equal to active(1)." + ::= { f3AccFpQosShaperEntry 14 } + +-- +-- Access Flow Point QoS Policer +-- +f3AccFpQosPolicerTable OBJECT-TYPE + SYNTAX SEQUENCE OF F3AccFpQosPolicerEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of entries corresponding to Access Flow Point + Quality of Service Policer for configuration purposes." + ::= { f3FpmConfigObjects 3 } + +f3AccFpQosPolicerEntry OBJECT-TYPE + SYNTAX F3AccFpQosPolicerEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A conceptual row in the f3AccFpQosPolicerTable. + These entries represent an Access Flow Point Quality + of Service Policer." + INDEX { neIndex, shelfIndex, slotIndex, cmEthernetAccPortIndex, + f3AccFlowPointIndex, f3AccFpQosPolicerIndex } + ::= { f3AccFpQosPolicerTable 1 } + +F3AccFpQosPolicerEntry ::= SEQUENCE { + f3AccFpQosPolicerIndex Integer32, + + f3AccFpQosPolicerAdminState AdminState, + f3AccFpQosPolicerOperationalState OperationalState, + f3AccFpQosPolicerSecondaryState SecondaryState, + + f3AccFpQosPolicerCIRLo Unsigned32, + f3AccFpQosPolicerCIRHi Unsigned32, + f3AccFpQosPolicerEIRLo Unsigned32, + f3AccFpQosPolicerEIRHi Unsigned32, + f3AccFpQosPolicerCBS Integer32, + f3AccFpQosPolicerEBS Integer32, + + f3AccFpQosPolicerAlgorithm PolicerAlgorithmType, + f3AccFpQosPolicerColorMode PolicerColorMode, + f3AccFpQosPolicerCouplingFlag TruthValue, + f3AccFpQosPolicerPolicingEnabled TruthValue, + + f3AccFpQosPolicerStorageType StorageType, + f3AccFpQosPolicerRowStatus RowStatus +} + +f3AccFpQosPolicerIndex OBJECT-TYPE + SYNTAX Integer32 (1..8) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The unique integer index value corresponding to a Quality + of Service Policer. + The Policer Index represents the COS level. This + is applicable in case of a Multi COS Flow Point. Index 1 + represents COS 0; Index 2 represents COS 1 and so on." + ::= { f3AccFpQosPolicerEntry 1 } + +f3AccFpQosPolicerAdminState OBJECT-TYPE + SYNTAX AdminState + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object represents the Administrative State of a Policer." + ::= { f3AccFpQosPolicerEntry 2 } + +f3AccFpQosPolicerOperationalState OBJECT-TYPE + SYNTAX OperationalState + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object represents the Operational State of a Policer." + ::= { f3AccFpQosPolicerEntry 3 } + +f3AccFpQosPolicerSecondaryState OBJECT-TYPE + SYNTAX SecondaryState + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object represents the Secondary State of a Policer." + ::= { f3AccFpQosPolicerEntry 4 } + +f3AccFpQosPolicerCIRLo OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object represents the Commited Information Rate (CIR) + (Lower 32 bits) of the Policer." + ::= { f3AccFpQosPolicerEntry 5 } + +f3AccFpQosPolicerCIRHi OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object represents the Commited Information Rate (CIR) + (Higher 32 bits) of the Policer." + ::= { f3AccFpQosPolicerEntry 6 } + +f3AccFpQosPolicerEIRLo OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object represents the Excess Information Rate (EIR) + (Lower 32 bits) of a Policer." + ::= { f3AccFpQosPolicerEntry 7 } + +f3AccFpQosPolicerEIRHi OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object represents the Excess Information Rate (EIR) + (Lower 32 bits) of a Policer." + ::= { f3AccFpQosPolicerEntry 8 } + +f3AccFpQosPolicerCBS OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object represents the Commited Burst Size (CBS) + of a Policer." + ::= { f3AccFpQosPolicerEntry 9 } + +f3AccFpQosPolicerEBS OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object represents the Excess Burst Size (EBS) + of a Policer." + ::= { f3AccFpQosPolicerEntry 10 } + +f3AccFpQosPolicerAlgorithm OBJECT-TYPE + SYNTAX PolicerAlgorithmType + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object represents Policer algorithm as 'srTCM' + (Single Rate Triple Color Marking) or 'trTCM' + (Two Rate Triple Color Marking)." + ::= { f3AccFpQosPolicerEntry 11 } + +f3AccFpQosPolicerColorMode OBJECT-TYPE + SYNTAX PolicerColorMode + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object allows specification of Policer Color Mode as + 'color-aware' or 'color-blind'." + ::= { f3AccFpQosPolicerEntry 12 } + +f3AccFpQosPolicerCouplingFlag OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object allows specification of Policer Coupling Flag. + When coupling is enabled, tokens that would normally be + added to the C-bucket are passed to the E-bucket only once the CIR + bucket has reached its CBS level. Therefore under this condition + the E-bucket is being filled at the rate of CIR + EIR. + Normally the long term average of frames declared yellow is + bounded by the EIR. Coupling is a function to allow the + long term average of frames declared yellow to be bounded by + CIR + EIR. This allows a higher volume of yellow frames + to be delivered/received if the arrival of green marked frames + is low. Tokens from the E-bucket do NOT get passed to the + C-bucket once the EBS level has been reached. + Enabling coupling in combination with a provisioned EIR of 0 + allows for a single rate three color marking (srTCM) algorithm + to be established. In this situation the E-bucket is filled at the + CIR rate in the case the C-bucket is filled to its CBS level." + ::= { f3AccFpQosPolicerEntry 13 } + +f3AccFpQosPolicerPolicingEnabled OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object allows specification of Policer Policing. + When Policing is disabled, traffic policing is bypassed. + When Policing is enabled, traffic policing is applied." + ::= { f3AccFpQosPolicerEntry 14 } + +f3AccFpQosPolicerStorageType OBJECT-TYPE + SYNTAX StorageType + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The type of storage configured for this entry." + ::= { f3AccFpQosPolicerEntry 15 } + +f3AccFpQosPolicerRowStatus OBJECT-TYPE + SYNTAX RowStatus + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The status of this row. + An entry MUST NOT exist in the active state unless all + objects in the entry have an appropriate value, as described + in the description clause for each writable object. + + The values of f3AccFpQosPolicerRowStatus supported are + createAndGo(4) and destroy(6). All mandatory attributes + must be specified in a single SNMP SET request with + f3AccFpQosPolicerRowStatus value as createAndGo(4). + Upon successful row creation, this object has a + value of active(1). + + The f3AccFpQosPolicerRowStatus object may be modified if + the associated instance of this object is equal to active(1)." + ::= { f3AccFpQosPolicerEntry 16 } + +-- +-- cmMPFlowTable extension for maximum forwarding table size configurations +-- +f3MPFlowExtTable OBJECT-TYPE + SYNTAX SEQUENCE OF F3MPFlowExtEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table extends cmMPFlowTable to provide configuration of maximum + forwarding table size." + ::= { f3FpmConfigObjects 4 } + +f3MPFlowExtEntry OBJECT-TYPE + SYNTAX F3MPFlowExtEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A conceptual row in the f3MPFlowExtTable." + AUGMENTS { cmMPFlowEntry } + ::= { f3MPFlowExtTable 1 } + +F3MPFlowExtEntry ::= SEQUENCE { + f3MPFlowExtMaxFwdEntries Integer32, + f3MPFlowRefConnectGuardFlowObject VariablePointer, + f3MPFlowSecureState FlowSecState +} + +f3MPFlowExtMaxFwdEntries OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object allows configuring the maximum number of Forwarding Entires + for Forwarding Table of this MP Flow." + ::= { f3MPFlowExtEntry 1 } + +f3MPFlowRefConnectGuardFlowObject OBJECT-TYPE + SYNTAX VariablePointer + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object specifies Mac Sec flow object OID." + ::= { f3MPFlowExtEntry 2 } + +f3MPFlowSecureState OBJECT-TYPE + SYNTAX FlowSecState + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object specifies the secure state of the macsec flow." + ::= { f3MPFlowExtEntry 3 } + +-- +-- Access Flow Point Control Protocol Disposition +-- +f3AccFlowPointCpdV2Table OBJECT-TYPE + SYNTAX SEQUENCE OF F3AccFlowPointCpdV2Entry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of entries corresponding to Access Flow Point + Control Protocol Disposition V2." + ::= { f3FpmConfigObjects 5 } + +f3AccFlowPointCpdV2Entry OBJECT-TYPE + SYNTAX F3AccFlowPointCpdV2Entry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A conceptual row in the f3AccFlowPointCpdV2Table. + These entries represent a Control Protocol Disposition + filtering criteria on the Access Flow Point." + INDEX { neIndex, shelfIndex, slotIndex, cmEthernetAccPortIndex, + f3AccFlowPointIndex, f3AccFlowPointCpdV2Index } + ::= { f3AccFlowPointCpdV2Table 1 } + +F3AccFlowPointCpdV2Entry ::= SEQUENCE { + f3AccFlowPointCpdV2Index Integer32, + f3AccFlowPointCpdV2IslDispType CmControlProtocolDispType, + f3AccFlowPointCpdV2PagpDispType CmControlProtocolDispType, + f3AccFlowPointCpdV2UdldDispType CmControlProtocolDispType, + f3AccFlowPointCpdV2CdpDispType CmControlProtocolDispType, + f3AccFlowPointCpdV2VtpDispType CmControlProtocolDispType, + f3AccFlowPointCpdV2DtpDispType CmControlProtocolDispType, + f3AccFlowPointCpdV2PvstpPlusDispType CmControlProtocolDispType, + f3AccFlowPointCpdV2UplinkFastDispType CmControlProtocolDispType, + f3AccFlowPointCpdV2VlanBridgeDispType CmControlProtocolDispType, + f3AccFlowPointCpdV2L2PTDispType CmControlProtocolDispType, + f3AccFlowPointCpdV2BPDUDispType CmControlProtocolDispType, + f3AccFlowPointCpdV2PauseDispType CmControlProtocolDispType, + f3AccFlowPointCpdV2LACPDispType CmControlProtocolDispType, + f3AccFlowPointCpdV2LACPMarkerDispType CmControlProtocolDispType, + f3AccFlowPointCpdV2EfmOamDispType CmControlProtocolDispType, + f3AccFlowPointCpdV2SSMDispType CmControlProtocolDispType, + f3AccFlowPointCpdV2PortAuthenDispType CmControlProtocolDispType, + f3AccFlowPointCpdV2LANBridgesDispType CmControlProtocolDispType, + f3AccFlowPointCpdV2GMRPDispType CmControlProtocolDispType, + f3AccFlowPointCpdV2GVRPDispType CmControlProtocolDispType, + f3AccFlowPointCpdV2GARPDispType CmControlProtocolDispType, + f3AccFlowPointCpdV2ActiveControlProtocols CmActiveControlProtocolsType, + f3AccFlowPointCpdV2ELMIDispType CmControlProtocolDispType, + f3AccFlowPointCpdV2Mac00DispType CmControlProtocolDispType, + f3AccFlowPointCpdV2Mac01DispType CmControlProtocolDispType, + f3AccFlowPointCpdV2Mac02DispType CmControlProtocolDispType, + f3AccFlowPointCpdV2Mac03DispType CmControlProtocolDispType, + f3AccFlowPointCpdV2Mac04DispType CmControlProtocolDispType, + f3AccFlowPointCpdV2Mac05DispType CmControlProtocolDispType, + f3AccFlowPointCpdV2Mac06DispType CmControlProtocolDispType, + f3AccFlowPointCpdV2Mac07DispType CmControlProtocolDispType, + f3AccFlowPointCpdV2Mac08DispType CmControlProtocolDispType, + f3AccFlowPointCpdV2Mac09DispType CmControlProtocolDispType, + f3AccFlowPointCpdV2Mac0ADispType CmControlProtocolDispType, + f3AccFlowPointCpdV2Mac0BDispType CmControlProtocolDispType, + f3AccFlowPointCpdV2Mac0CDispType CmControlProtocolDispType, + f3AccFlowPointCpdV2Mac0DDispType CmControlProtocolDispType, + f3AccFlowPointCpdV2Mac0EDispType CmControlProtocolDispType, + f3AccFlowPointCpdV2Mac0FDispType CmControlProtocolDispType, + f3AccFlowPointCpdV2NearestLLDPDispType CmControlProtocolDispType, + f3AccFlowPointCpdV2NonTpmrLLDPDispType CmControlProtocolDispType, + f3AccFlowPointCpdV2CustomerLLDPDispType CmControlProtocolDispType +} + +f3AccFlowPointCpdV2Index OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Unique Index value to access the CPD row." + ::= { f3AccFlowPointCpdV2Entry 1 } + +f3AccFlowPointCpdV2IslDispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Control Protocol Disposition for ISL (Inter Switch Link). + MAC Address (01:00:0C:00:00:00)." + ::= { f3AccFlowPointCpdV2Entry 2 } + +f3AccFlowPointCpdV2PagpDispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Control Protocol Disposition for PAGP (Port Aggregation Protocol). + MAC Address (01:00:0C:CC:CC:CC), Ethertype(0x104)." + ::= { f3AccFlowPointCpdV2Entry 3 } + +f3AccFlowPointCpdV2UdldDispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Control Protocol Disposition for UDLD (Unidirectional Link Detection). + MAC Address (01:00:0C:CC:CC:CC), Ethertype(0x111)." + ::= { f3AccFlowPointCpdV2Entry 4 } + +f3AccFlowPointCpdV2CdpDispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Control Protocol Disposition for CDP (Cisco Discovery Protocol). + MAC Address (01:00:0C:CC:CC:CC), Ethertype(0x2000)." + ::= { f3AccFlowPointCpdV2Entry 5 } + +f3AccFlowPointCpdV2VtpDispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Control Protocol Disposition for VTP (VLAN Trunking Protocol). + MAC Address (01:00:0C:CC:CC:CC), Ethertype(0x2003)." + ::= { f3AccFlowPointCpdV2Entry 6 } + +f3AccFlowPointCpdV2DtpDispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Control Protocol Disposition for DTP (Dynamic Trunking). + MAC Address (01:00:0C:CC:CC:CC), Ethertype(0x2004)." + ::= { f3AccFlowPointCpdV2Entry 7 } + +f3AccFlowPointCpdV2PvstpPlusDispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Control Protocol Disposition for Spanning Tree PVSTP+. + MAC Address (01:00:0C:CC:CC:CC), Ethertype(0x10B)." + ::= { f3AccFlowPointCpdV2Entry 8 } + +f3AccFlowPointCpdV2UplinkFastDispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Control Protocol Disposition for STP UplinkFast. + MAC Address (01:00:0C:CD:CD:CD), Ethertype(0x200A)." + ::= { f3AccFlowPointCpdV2Entry 9 } + +f3AccFlowPointCpdV2VlanBridgeDispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Control Protocol Disposition for VLAN Bridge. + MAC Address (01:00:0C:CD:CD:CE), Ethertype(0x10C)." + ::= { f3AccFlowPointCpdV2Entry 10 } + +f3AccFlowPointCpdV2L2PTDispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Control Protocol Disposition for Layer 2 Protocol Tunnelling(L2PT). + MAC Address (01:00:0C:CD:CD:D0)." + ::= { f3AccFlowPointCpdV2Entry 11 } + +f3AccFlowPointCpdV2BPDUDispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Control Protocol Disposition for IEEE Spanning Tree(STP), + MSTP (Multiple Spanning Tree) and RSTP (Rapid Reconfiguration of + Spanning Tree). MAC Address (01:80:C2:00:00:00)." + ::= { f3AccFlowPointCpdV2Entry 12 } + +f3AccFlowPointCpdV2PauseDispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Control Protocol Disposition for IEEE 802.3x Flow Control + (PAUSE frames)." + ::= { f3AccFlowPointCpdV2Entry 13 } + +f3AccFlowPointCpdV2LACPDispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Control Protocol Disposition for 802.3ad Link Aggregation + Protocol. + MAC Address (01:80:C2:00:00:03), Ethertype (0x8809), Subtype(01)." + ::= { f3AccFlowPointCpdV2Entry 14 } + +f3AccFlowPointCpdV2LACPMarkerDispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Control Protocol Disposition for IEEE 802.3ad Marker Protocol. + MAC Address (01:80:C2:00:00:03), Ethertype (0x8809), Subtype(02)." + ::= { f3AccFlowPointCpdV2Entry 15 } + +f3AccFlowPointCpdV2EfmOamDispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Control Protocol Disposition for IEEE 802.3ah EFM OAM. + MAC Address (01:80:C2:00:00:03), Ethertype (0x8809), Subtype(03)." + ::= { f3AccFlowPointCpdV2Entry 16 } + +f3AccFlowPointCpdV2SSMDispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Control Protocol Disposition for Sync Status Messages. + MAC Address (01:80:C2:00:00:02), Ethertype (0x19A7), Subtype(0A)." + ::= { f3AccFlowPointCpdV2Entry 17 } + +f3AccFlowPointCpdV2PortAuthenDispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Control Protocol Disposition for IEEE 802.1x Protocol. + MAC Address (01:80:C2:00:00:03), Ethertype (0x888E)." + ::= { f3AccFlowPointCpdV2Entry 18 } + +f3AccFlowPointCpdV2LANBridgesDispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Control Protocol Disposition for IEEE 802.1d LAN Bridge Managment. + MAC Address (01:80:C2:00:00:10)." + ::= { f3AccFlowPointCpdV2Entry 19 } + +f3AccFlowPointCpdV2GMRPDispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Control Protocol Disposition for GARP Multicast Registration + Protocol. MAC Address (01:80:C2:00:00:20)." + ::= { f3AccFlowPointCpdV2Entry 20 } + +f3AccFlowPointCpdV2GVRPDispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Control Protocol Disposition for GARP VLAN Registration + Protocol. MAC Address (01:80:C2:00:00:21)." + ::= { f3AccFlowPointCpdV2Entry 21 } + +f3AccFlowPointCpdV2GARPDispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Group Disposition type which includes GARP Reserved + MAC Address from range 01:80:C2:00:00:22 to 01:80:C2:00:00:2F." + ::= { f3AccFlowPointCpdV2Entry 22 } + +f3AccFlowPointCpdV2ActiveControlProtocols OBJECT-TYPE + SYNTAX CmActiveControlProtocolsType + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "List of Active Control Protocol Dispositions. Note that + if the Port Level Disposition control is set to PEER or + DISCARD, the flow level disposition is no longer active. + This object provides information on all the active + dispositions." + ::= { f3AccFlowPointCpdV2Entry 23 } + +f3AccFlowPointCpdV2ELMIDispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ELMI (Ethernet Local Management Interface) Disposition type. + MAC Address 01:80:C2:00:00:07 and EtherType of 0x88EE." + ::= { f3AccFlowPointCpdV2Entry 24 } + +f3AccFlowPointCpdV2Mac00DispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "MAC Address 01:80:C2:00:00:00 Disposition type." + ::= { f3AccFlowPointCpdV2Entry 25 } + +f3AccFlowPointCpdV2Mac01DispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "MAC Address 01:80:C2:00:00:01 Disposition type." + ::= { f3AccFlowPointCpdV2Entry 26 } + +f3AccFlowPointCpdV2Mac02DispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "MAC Address 01:80:C2:00:00:02 Disposition type." + ::= { f3AccFlowPointCpdV2Entry 27 } + +f3AccFlowPointCpdV2Mac03DispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "MAC Address 01:80:C2:00:00:03 Disposition type." + ::= { f3AccFlowPointCpdV2Entry 28 } + +f3AccFlowPointCpdV2Mac04DispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "MAC Address 01:80:C2:00:00:04 Disposition type." + ::= { f3AccFlowPointCpdV2Entry 29 } + +f3AccFlowPointCpdV2Mac05DispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "MAC Address 01:80:C2:00:00:05 Disposition type." + ::= { f3AccFlowPointCpdV2Entry 30 } + +f3AccFlowPointCpdV2Mac06DispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "MAC Address 01:80:C2:00:00:06 Disposition type." + ::= { f3AccFlowPointCpdV2Entry 31 } + +f3AccFlowPointCpdV2Mac07DispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "MAC Address 01:80:C2:00:00:07 Disposition type." + ::= { f3AccFlowPointCpdV2Entry 32 } + +f3AccFlowPointCpdV2Mac08DispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "MAC Address 01:80:C2:00:00:08 Disposition type." + ::= { f3AccFlowPointCpdV2Entry 33 } + +f3AccFlowPointCpdV2Mac09DispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "MAC Address 01:80:C2:00:00:09 Disposition type." + ::= { f3AccFlowPointCpdV2Entry 34 } + +f3AccFlowPointCpdV2Mac0ADispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "MAC Address 01:80:C2:00:00:0A Disposition type." + ::= { f3AccFlowPointCpdV2Entry 35 } + +f3AccFlowPointCpdV2Mac0BDispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "MAC Address 01:80:C2:00:00:0B Disposition type." + ::= { f3AccFlowPointCpdV2Entry 36 } + +f3AccFlowPointCpdV2Mac0CDispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "MAC Address 01:80:C2:00:00:0C Disposition type." + ::= { f3AccFlowPointCpdV2Entry 37 } + +f3AccFlowPointCpdV2Mac0DDispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "MAC Address 01:80:C2:00:00:0D Disposition type." + ::= { f3AccFlowPointCpdV2Entry 38 } + +f3AccFlowPointCpdV2Mac0EDispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "MAC Address 01:80:C2:00:00:0E Disposition type." + ::= { f3AccFlowPointCpdV2Entry 39 } + +f3AccFlowPointCpdV2Mac0FDispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "MAC Address 01:80:C2:00:00:0F Disposition type." + ::= { f3AccFlowPointCpdV2Entry 40 } + +f3AccFlowPointCpdV2NearestLLDPDispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "LLDP (Link Layer Discovery Protocol) Nearest Bridge Disposition type." + ::= { f3AccFlowPointCpdV2Entry 41 } + +f3AccFlowPointCpdV2NonTpmrLLDPDispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "LLDP (Link Layer Discovery Protocol) Non-TPMR Bridge Disposition type." + ::= { f3AccFlowPointCpdV2Entry 42 } + +f3AccFlowPointCpdV2CustomerLLDPDispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "LLDP (Link Layer Discovery Protocol) Customer Bridge Disposition type." + ::= { f3AccFlowPointCpdV2Entry 43 } + +-- +-- Access Flowpoint table extension for Learning Control configuration +-- +f3AccFlowPointLearningConfigTable OBJECT-TYPE + SYNTAX SEQUENCE OF F3AccFlowPointLearningConfigEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table extends f3AccFlowPointTable to provide parameters for MAC Table control + configuration." + ::= { f3FpmConfigObjects 6 } + +f3AccFlowPointLearningConfigEntry OBJECT-TYPE + SYNTAX F3AccFlowPointLearningConfigEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A conceptual row in the f3AccFlowPointLearningConfigTable." + AUGMENTS { f3AccFlowPointEntry } + ::= { f3AccFlowPointLearningConfigTable 1 } + +F3AccFlowPointLearningConfigEntry ::= SEQUENCE { + f3AccFlowPointLearningConfigLearningEnabled TruthValue, + f3AccFlowPointLearningConfigMaxFwdEntries Integer32, + f3AccFlowPointLearningConfigProtectLearningCtrl ProtectLearningControl, + f3AccFlowPointLearningConfigAction FlowLearningConfigAction +} + +f3AccFlowPointLearningConfigLearningEnabled OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object allows configuring Learning Control on this Flowpoint." + ::= { f3AccFlowPointLearningConfigEntry 1 } + +f3AccFlowPointLearningConfigMaxFwdEntries OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object allows configuring the maximum number of Forwarding Entries + on this Flowpoint." + ::= { f3AccFlowPointLearningConfigEntry 2 } + +f3AccFlowPointLearningConfigProtectLearningCtrl OBJECT-TYPE + SYNTAX ProtectLearningControl + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object allows configuring Learning Control on this Flowpoint." + ::= { f3AccFlowPointLearningConfigEntry 3 } + +f3AccFlowPointLearningConfigAction OBJECT-TYPE + SYNTAX FlowLearningConfigAction + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This objects allows performing user action on Flow Learning Table." + ::= { f3AccFlowPointLearningConfigEntry 4 } + +-- +-- Network Flow Point Table +-- + +f3NetFlowPointTable OBJECT-TYPE + SYNTAX SEQUENCE OF F3NetFlowPointEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of entries corresponding to Network Flow Point + for configuration purposes." + ::= { f3FpmConfigObjects 7 } + +f3NetFlowPointEntry OBJECT-TYPE + SYNTAX F3NetFlowPointEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A conceptual row in the f3NetFlowPointTable. + These entries represent an Network Flow Point. + If the Flow Point attached to a lag, the slotIndex should + be 255 (255 is used to identify the Flow Point belongs to lag), + and the cmEthernetNetPortIndex should be the f3LagIndex." + + INDEX { neIndex, shelfIndex, slotIndex, cmEthernetNetPortIndex, f3NetFlowPointIndex } + ::= { f3NetFlowPointTable 1 } + +F3NetFlowPointEntry ::= SEQUENCE { + f3NetFlowPointIndex Integer32, + f3NetFlowPointAlias DisplayString, + + f3NetFlowPointAdminState AdminState, + f3NetFlowPointOperationalState OperationalState, + f3NetFlowPointSecondaryState SecondaryState, + + f3NetFlowPointAssociatedFlowId VariablePointer, + + f3NetFlowPointIngressMultiCOSEnabled TruthValue, + f3NetFlowPointIngressCOS Integer32, + f3NetFlowPointEgressShapingType ShapingType, + + f3NetFlowPointIngressVlanMemberList DisplayString, + f3NetFlowPointVlanMemberAction FlowVlanActionType, + f3NetFlowPointVlanMemberActionVlan DisplayString, + f3NetFlowPointIngressUntaggedFrameEnabled TruthValue, + + f3NetFlowPointCTagControl FlowTagControl, + f3NetFlowPointCTagVlanId VlanId, + f3NetFlowPointCTagVlanPriority VlanPriority, + f3NetFlowPointSTagControl FlowTagControl, + f3NetFlowPointSTagVlanId VlanId, + f3NetFlowPointSTagVlanPriority VlanPriority, + + f3NetFlowPointEgressOuterTagPrioMapEnabled TruthValue, + f3NetFlowPointEgressInnerTagPrioMapEnabled TruthValue, + f3NetFlowPointSESFramesLossThresholdRatio Integer32, + f3NetFlowPointDefaultMemberEnabled TruthValue, + + f3NetFlowPointMcastRateLimitEnabled TruthValue, + f3NetFlowPointMcastRateLimitSpeedLo Unsigned32, + f3NetFlowPointMcastRateLimitSpeedHi Unsigned32, + f3NetFlowPointBcastRateLimitEnabled TruthValue, + f3NetFlowPointBcastRateLimitSpeedLo Unsigned32, + f3NetFlowPointBcastRateLimitSpeedHi Unsigned32, + f3NetFlowPointCombinedRateLimitEnabled TruthValue, + f3NetFlowPointCombinedRateLimitSpeedLo Unsigned32, + f3NetFlowPointCombinedRateLimitSpeedHi Unsigned32, + + f3NetFlowPointSplitHorizonGroupOID VariablePointer, + f3NetFlowPointLoopAvoidance VariablePointer, + f3NetFlowPointHierarchicalCOSEnabled TruthValue, + f3NetFlowPointMaximumBWLo Unsigned32, + f3NetFlowPointMaximumBWHi Unsigned32, + f3NetFlowPointGuaranteedBWLo Unsigned32, + f3NetFlowPointGuaranteedBWHi Unsigned32, + f3NetFlowPointAutoBandwidthConfigEnabled TruthValue, + f3NetFlowPointAutoCIRPercentage Integer32, + f3NetFlowPointFrameFwdEnabled TruthValue, + + f3NetFlowPointStorageType StorageType, + f3NetFlowPointRowStatus RowStatus, + + f3NetFlowPointUsePortPrioMapProfile TruthValue, + f3NetFlowPointRefPrioMapProfile VariablePointer, + f3NetFlowpointRefConnectGuardFlowObject VariablePointer, + f3NetFlowpointSecureBlockingControl TruthValue, + f3NetFlowpointSecureState FlowSecState +} + +f3NetFlowPointIndex OBJECT-TYPE + SYNTAX Integer32 (1..65535) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The integer index value corresponding to an Flow Point." + ::= { f3NetFlowPointEntry 1 } + +f3NetFlowPointAlias OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..64)) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object allows SNMP management entities to provide a + circuit identifier with the Flow Point." + ::= { f3NetFlowPointEntry 2 } + +f3NetFlowPointAdminState OBJECT-TYPE + SYNTAX AdminState + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object represents the Administrative State of the Flow Point." + ::= { f3NetFlowPointEntry 3 } + +f3NetFlowPointOperationalState OBJECT-TYPE + SYNTAX OperationalState + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object represents the Operational State of the Flow Point." + ::= { f3NetFlowPointEntry 4 } + +f3NetFlowPointSecondaryState OBJECT-TYPE + SYNTAX SecondaryState + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object represents the Secondary State of the Flow Point." + ::= { f3NetFlowPointEntry 5 } + +f3NetFlowPointAssociatedFlowId OBJECT-TYPE + SYNTAX VariablePointer + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object provides the association of an Flow with an Flow Point." + ::= { f3NetFlowPointEntry 6 } + +f3NetFlowPointIngressMultiCOSEnabled OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object allows specification of ingress multiple COS + (Class of Service) Flow Point." + ::= { f3NetFlowPointEntry 7 } + +f3NetFlowPointIngressCOS OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-create + STATUS deprecated + DESCRIPTION + "This object allows specification of ingress COS + (Class of Service) Flow Point. + + This attribute has been deprecated and is not supported. The + Ingress COS is determined from the flowpoint's associated + Priority Mapping Profle." + ::= { f3NetFlowPointEntry 8 } + +f3NetFlowPointEgressShapingType OBJECT-TYPE + SYNTAX ShapingType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object allows specification of Shaping Type for Flow Point. + For 8.1.1 release, only flow-based Shaping Type is supported." + ::= { f3NetFlowPointEntry 9 } + +f3NetFlowPointIngressVlanMemberList OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..512)) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "It allows specification of VLAN members of the Flow Point. + VLAN members are comma separated, of the form X-Y where X is the + VLAN Id and Y is the VLAN Priority. VLAN members can be of + the form X-* or X (vlan X with all priorities), *-Y (all vlans + with priority Y), and X1:X2 (range of vlans from X1 to X2, + all priorities). Members with specific VLAN Id and specific + VLAN Priority are not supported. Once the Flow Point is created, + this attribute can only be updated using f3NetFlowPointVlanMemberAction + and f3NetFlowPointVlanMemberActionVlan objects." + ::= { f3NetFlowPointEntry 10 } + +f3NetFlowPointVlanMemberAction OBJECT-TYPE + SYNTAX FlowVlanActionType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object allows to add or remove the VLAN members specified by + f3NetFlowPointVlanMemberActionVlan object. SNMP manager must first + configure the VLAN member to be added/removed in the object + f3NetFlowPointVlanMemberActionVlan and then should specify + f3NetFlowPointVlanMemberAction on whether to add/remove the specified + VLAN member." + ::= { f3NetFlowPointEntry 11 } + +f3NetFlowPointVlanMemberActionVlan OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..16)) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object allows adding/removing VLAN members to a Flow Point. + VLAN member is of the form X-Y where X is the VLAN Id and Y is + the VLAN Priority. VLAN members can be of the form X-* (vlan X + with all priorities), *-Y (all vlans with priority Y), and X1:X2 + (range of vlans from X1 to X2, all priorities). Members with + specific VLAN Id and specific VLAN Priority are not supported. + In order to add/remove VLAN member to a flow, user must specify + this object with appropriate VLAN and then + invoke f3NetFlowPointVlanMemberAction." + ::= { f3NetFlowPointEntry 12 } + +f3NetFlowPointIngressUntaggedFrameEnabled OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object allows to specify whether or not the Flow Point + supports untagged frame." + ::= { f3NetFlowPointEntry 13 } + +f3NetFlowPointCTagControl OBJECT-TYPE + SYNTAX FlowTagControl + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object allows specification of the tag management + operation on the C-TAG. Supported types are 'push', 'pushvid', + 'swaptag', 'swapvid' and 'none'. If the type is 'push', + the VLAN Id (f3NetFlowPointCTagVlanId) and priority + (f3NetFlowPointCTagVlanPriority) are pushed onto the frame; + if the type is 'pushvid', only the VLAN Id (12 bits) is pushed, + the Priority is copied from incoming tag's priority; + if the type is 'swaptag', both VLAN Id and Priority (15 bits) + are swapped with the specified f3NetFlowPointCTagVlanId and + f3NetFlowPointCTagVlanPriority; + if the type is 'swapvid', only the VLAN Id (12 bits) are + swapped with the specified f3NetFlowPointCTagVlanId; + if the type is 'none', no C-TAG management is performed." + ::= { f3NetFlowPointEntry 14 } + +f3NetFlowPointCTagVlanId OBJECT-TYPE + SYNTAX VlanId + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object allows specification of the VLAN Id to + be pushed or swapped, based on the value of + f3NetFlowPointIngressCTagControl. It is applicable + for 'push', 'swaptag', 'swapvid' and 'pushvid' control types." + ::= { f3NetFlowPointEntry 15 } + +f3NetFlowPointCTagVlanPriority OBJECT-TYPE + SYNTAX VlanPriority + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object allows specification of the VLAN Priority to + be pushed or swapped, based on the value of f3NetFlowPointIngressCTagControl. + It is applicable for 'push' and 'swaptag' control types." + ::= { f3NetFlowPointEntry 16 } + +f3NetFlowPointSTagControl OBJECT-TYPE + SYNTAX FlowTagControl + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object allows specification of the tag management + operation on the S-TAG. Supported types are 'push', 'pushvid', + 'swaptag', 'swapvid' and 'none'. If the type is 'push', + the VLAN Id (f3NetFlowPointSTagVlanId) and priority + (f3NetFlowPointSTagVlanPriority) are pushed onto the frame; + if the type is 'pushvid', only the VLAN Id (12 bits) is pushed, + the Priority is copied from incoming tag's priority; + if the type is 'swaptag', both VLAN Id and Priority (15 bits) + are swapped with the specified f3NetFlowPointSTagVlanId and + f3NetFlowPointSTagVlanPriority; + if the type is 'swapvid', only the VLAN Id (12 bits) are + swapped with the specified f3NetFlowPointSTagVlanId; + if the type is 'none', no S-TAG management is performed." + ::= { f3NetFlowPointEntry 17 } + +f3NetFlowPointSTagVlanId OBJECT-TYPE + SYNTAX VlanId + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object allows specification of the VLAN Id to + be pushed or swapped, based on the value of + f3NetFlowPointIngressSTagControl. It is applicable + for 'push', 'swaptag', 'swapvid' and 'pushvid' control types." + ::= { f3NetFlowPointEntry 18 } + +f3NetFlowPointSTagVlanPriority OBJECT-TYPE + SYNTAX VlanPriority + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object allows specification of the VLAN Priority to + be pushed or swapped, based on the value of + f3NetFlowPointIngressSTagControl. It is applicable + for 'push' and 'swaptag' control types." + ::= { f3NetFlowPointEntry 19 } + +f3NetFlowPointEgressOuterTagPrioMapEnabled OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object defines whether to use the Egress Prio + Mapping to swap the priority of outer tag. When Enabled, + it indicates that the operation specified in the + EgressPrioMapTable would be applied to Flow for specified COS. + When Disabled,the EgressPrioMapTable operations are ignored + for specified Flow COS." + ::= { f3NetFlowPointEntry 20 } + +f3NetFlowPointEgressInnerTagPrioMapEnabled OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object defines whether to use the Egress Prio + Mapping to swap the priority of inner tag. When Enabled, + it indicates that the operation specified in the + EgressPrioMapTable would be applied to Flow for specified COS. + When Disabled, the EgressPrioMapTable operations are ignored + for specified Flow COS." + ::= { f3NetFlowPointEntry 21 } + +f3NetFlowPointSESFramesLossThresholdRatio OBJECT-TYPE + SYNTAX Integer32 (0..100) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object is used to specify the frame-loss ratio + per flow that starts counting Severely Errored Seconds (SES) + on the flowpoint. + This functionality is applicable if the flowpoint is monitored + using the Y.1731 ESA functionality." + ::= { f3NetFlowPointEntry 22 } + +f3NetFlowPointDefaultMemberEnabled OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Truth Value means that on this FP, the membership is all the tag + packets without match any other membership associated to the port. + Untagged means untagged flow. Default only care tagged flow." + ::= { f3NetFlowPointEntry 23 } + +f3NetFlowPointMcastRateLimitEnabled OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Whether multicast packets need be limited per FP." + ::= { f3NetFlowPointEntry 24 } + +f3NetFlowPointMcastRateLimitSpeedLo OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The rate limiting for multicast packets per FP. When + f3NetFlowPointMcastRateLimitEnabled and the value is 0, + it means all multicast frame are dropped. This objects + only represents low 32 bits." + ::= { f3NetFlowPointEntry 25 } + +f3NetFlowPointMcastRateLimitSpeedHi OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The rate limiting for multicast packets per FP. When + f3NetFlowPointMcastRateLimitEnabled and the value is 0, + it means all multicast frame are dropped. This objects + only represents high 32 bits." + ::= { f3NetFlowPointEntry 26 } + +f3NetFlowPointBcastRateLimitEnabled OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Whether broadcast packets need be limited per FP." + ::= { f3NetFlowPointEntry 27 } + +f3NetFlowPointBcastRateLimitSpeedLo OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The rate limiting for broadcast packets per FP. When + f3NetFlowPointBcastRateLimitEnabled and the value is 0, + it means all multicast frame are dropped. This objects + only represents low 32 bits." + ::= { f3NetFlowPointEntry 28 } + +f3NetFlowPointBcastRateLimitSpeedHi OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The rate limiting for broadcast packets per FP. When + f3NetFlowPointBcastRateLimitEnabled and the value is 0, + it means all multicast frame are dropped. This objects + only represents high 32 bits." + ::= { f3NetFlowPointEntry 29 } + +f3NetFlowPointCombinedRateLimitEnabled OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Whether broadcast and multicast packets need be limited per FP." + ::= { f3NetFlowPointEntry 30 } + +f3NetFlowPointCombinedRateLimitSpeedLo OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The rate limiting for broadcast and multicast packets per FP. + When f3NetFlowPointCombinedRateLimitEnabled is true and the value is 0, + it means all broadcast and multicast frame are dropped. This object + only represents low 32 bits." + ::= { f3NetFlowPointEntry 31 } + +f3NetFlowPointCombinedRateLimitSpeedHi OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The rate limiting for broadcast and multicast packets per FP. + When f3NetFlowPointCombinedRateLimitEnabled is true and the value is 0, + it means all broadcast and multicast frame are dropped. This object + only represents high 32 bits." + ::= { f3NetFlowPointEntry 32 } + +f3NetFlowPointSplitHorizonGroupOID OBJECT-TYPE + SYNTAX VariablePointer + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Specifies the Split-Horizon Group OID. If there is no SHG, the value is none." + ::= { f3NetFlowPointEntry 33 } + +f3NetFlowPointLoopAvoidance OBJECT-TYPE + SYNTAX VariablePointer + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "EID of this associated Loop Avoidance protocol entity. + A value of NONE indicates there is no loop avoidance protocol. + Currently ERP EID is filled when ELAN service is created." + ::= { f3NetFlowPointEntry 34 } + +f3NetFlowPointHierarchicalCOSEnabled OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Enable or Disable Hierarchical COS shaping (flow shaping)." + ::= { f3NetFlowPointEntry 35 } + +f3NetFlowPointMaximumBWLo OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This attribute description the Flow Point maximum bandwidth. + This object only represents low 32 bits." + ::= { f3NetFlowPointEntry 36 } + +f3NetFlowPointMaximumBWHi OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This attribute description the Flow Point maximum bandwidth. + This object only represents high 32 bits." + ::= { f3NetFlowPointEntry 37 } + +f3NetFlowPointGuaranteedBWLo OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This attribute description the Flow Point guaranteed bandwidth. + This object only represents low 32 bits." + ::= { f3NetFlowPointEntry 38 } + +f3NetFlowPointGuaranteedBWHi OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This attribute description the Flow Point guaranteed bandwidth. + This objects only represents high 32 bits." + ::= { f3NetFlowPointEntry 39 } + +f3NetFlowPointAutoBandwidthConfigEnabled OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object specifies the shaper bandwidth is automatically adjusted + by the system. For a single COS Flow Point, the shaper EIR bandwidth is + set to the maximum port bandwidth; the shaper CIR is set to the available + port bandwidth multiplied by the value of the f3NetFlowPointAutoCIRPercentage + object. For a Hierarchical-COS Flow Point, the f3NetFlowPointMaximumBWLo and + f3NetFlowPointMaximumBWHi are set to the maximum port bandwidth; + the f3NetFlowPointGuaranteedBWLo and f3NetFlowPointGuaranteedBWHi are set to + the available port bandwidth multiplied by the value of the + f3NetFlowPointAutoCIRPercentage object. The value of this object must be FALSE + when f3NetFlowPointIngressMultiCOSEnabled is TRUE and + f3NetFlowPointHierarchicalCOSEnabled is FALSE." + ::= { f3NetFlowPointEntry 40 } + +f3NetFlowPointAutoCIRPercentage OBJECT-TYPE + SYNTAX Integer32 (0..100) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object specifies the percentage of available shaper CIR to be assigned + to this Flow Point when f3NetFlowPointAutoBandwidthConfigEnabled is TRUE." + ::= { f3NetFlowPointEntry 41 } + +f3NetFlowPointFrameFwdEnabled OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "When enabled Flow Point will forward frames it receives. + When disabled, the Flow Point will not forward frames it receives." + ::= { f3NetFlowPointEntry 42 } + +f3NetFlowPointStorageType OBJECT-TYPE + SYNTAX StorageType + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The type of storage configured for this entry." + ::= { f3NetFlowPointEntry 43 } + +f3NetFlowPointRowStatus OBJECT-TYPE + SYNTAX RowStatus + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The status of this row. + An entry MUST NOT exist in the active state unless all + objects in the entry have an appropriate value, as described + in the description clause for each writable object. + + The values of f3NetFlowPointRowStatus supported are + createAndGo(4) and destroy(6). All mandatory attributes + must be specified in a single SNMP SET request with + f3NetFlowPointRowStatus value as createAndGo(4). + Upon successful row creation, this object has a + value of active(1). + + The f3NetFlowPointRowStatus object may be modified if + the associated instance of this object is equal to active(1)." + ::= { f3NetFlowPointEntry 44 } + +f3NetFlowPointUsePortPrioMapProfile OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This indicates whether the flow point is using, if true, the port's + Priority Mapping Profile or, if false, is using its own + Priority Mapping Profile." + ::= { f3NetFlowPointEntry 45 } + +f3NetFlowPointRefPrioMapProfile OBJECT-TYPE + SYNTAX VariablePointer + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object allows to set priority map profile." + ::= { f3NetFlowPointEntry 46 } + +f3NetFlowpointRefConnectGuardFlowObject OBJECT-TYPE + SYNTAX VariablePointer + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object specifies Mac Sec flow object OID." + ::= { f3NetFlowPointEntry 47 } + +f3NetFlowpointSecureBlockingControl OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object can be used to enable/disable secure block." + ::= { f3NetFlowPointEntry 48 } + +f3NetFlowpointSecureState OBJECT-TYPE + SYNTAX FlowSecState + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object specifies the secure state of this flow." + ::= { f3NetFlowPointEntry 49 } + +-- +-- Net Flow Point QoS Shaper +-- + +f3NetFpQosShaperTable OBJECT-TYPE + SYNTAX SEQUENCE OF F3NetFpQosShaperEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of entries corresponding to Net Flow Point + Quality of Service Shaper for configuration purposes." + ::= { f3FpmConfigObjects 8 } + +f3NetFpQosShaperEntry OBJECT-TYPE + SYNTAX F3NetFpQosShaperEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A conceptual row in the f3NetFpQosShaperTable. + These entries represent an Net Flow Point Quality + of Service Shaper." + INDEX { neIndex, shelfIndex, slotIndex, cmEthernetNetPortIndex, + f3NetFlowPointIndex, f3NetFpQosShaperIndex } + ::= { f3NetFpQosShaperTable 1 } + +F3NetFpQosShaperEntry ::= SEQUENCE { + f3NetFpQosShaperIndex Integer32, + + f3NetFpQosShaperAdminState AdminState, + f3NetFpQosShaperOperationalState OperationalState, + f3NetFpQosShaperSecondaryState SecondaryState, + + f3NetFpQosShaperCIRLo Unsigned32, + f3NetFpQosShaperCIRHi Unsigned32, + f3NetFpQosShaperEIRLo Unsigned32, + f3NetFpQosShaperEIRHi Unsigned32, + f3NetFpQosShaperCBS Unsigned32, + f3NetFpQosShaperEBS Unsigned32, + f3NetFpQosShaperBufferSize Unsigned32, + f3NetFpQosShaperCOS Integer32, + + f3NetFpQosShaperStorageType StorageType, + f3NetFpQosShaperRowStatus RowStatus +} + +f3NetFpQosShaperIndex OBJECT-TYPE + SYNTAX Integer32 (1..8) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The unique integer index value corresponding to a Quality + of Service Shaper." + ::= { f3NetFpQosShaperEntry 1 } + +f3NetFpQosShaperAdminState OBJECT-TYPE + SYNTAX AdminState + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object represents the Administrative State of a Shaper." + ::= { f3NetFpQosShaperEntry 2 } + +f3NetFpQosShaperOperationalState OBJECT-TYPE + SYNTAX OperationalState + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object represents the Operational State of a Shaper." + ::= { f3NetFpQosShaperEntry 3 } + +f3NetFpQosShaperSecondaryState OBJECT-TYPE + SYNTAX SecondaryState + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object represents the Secondary State of the Shaper." + ::= { f3NetFpQosShaperEntry 4 } + +f3NetFpQosShaperCIRLo OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object represents the Commited Information Rate (CIR) + (Lower 32 bits) of the Shaper." + ::= { f3NetFpQosShaperEntry 5 } + +f3NetFpQosShaperCIRHi OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object represents the Commited Information Rate (CIR) + (Higher 32 bits) of the Shaper." + ::= { f3NetFpQosShaperEntry 6 } + +f3NetFpQosShaperEIRLo OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object represents the Excess Information Rate (EIR) + (Lower 32 bits) of a Shaper." + ::= { f3NetFpQosShaperEntry 7 } + +f3NetFpQosShaperEIRHi OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object represents the Excess Information Rate (EIR) + (Lower 32 bits) of a Shaper." + ::= { f3NetFpQosShaperEntry 8 } + +f3NetFpQosShaperCBS OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object represents the Commited Burst Size (CBS) + of a Shaper." + ::= { f3NetFpQosShaperEntry 9 } + +f3NetFpQosShaperEBS OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object represents the Excess Burst Size (EBS) + of a Shaper." + ::= { f3NetFpQosShaperEntry 10 } + +f3NetFpQosShaperBufferSize OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object represents the Buffer Size of the Shaper." + ::= { f3NetFpQosShaperEntry 11 } + +f3NetFpQosShaperCOS OBJECT-TYPE + SYNTAX Integer32 (0..7) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object provides the COS (Class of Service) value for + the QOS Shaper." + ::= { f3NetFpQosShaperEntry 12 } + +f3NetFpQosShaperStorageType OBJECT-TYPE + SYNTAX StorageType + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The type of storage configured for this entry." + ::= { f3NetFpQosShaperEntry 13 } + +f3NetFpQosShaperRowStatus OBJECT-TYPE + SYNTAX RowStatus + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The status of this row. + An entry MUST NOT exist in the active state unless all + objects in the entry have an appropriate value, as described + in the description clause for each writable object. + + The values of f3NetFpQosShaperRowStatus supported are + createAndGo(4) and destroy(6). All mandatory attributes + must be specified in a single SNMP SET request with + f3NetFpQosShaperRowStatus value as createAndGo(4). + Upon successful row creation, this object has a + value of active(1). + + The f3NetFpQosShaperRowStatus object may be modified if + the associated instance of this object is equal to active(1)." + ::= { f3NetFpQosShaperEntry 14 } + +-- +-- Net Flow Point QoS Policer +-- + +f3NetFpQosPolicerTable OBJECT-TYPE + SYNTAX SEQUENCE OF F3NetFpQosPolicerEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of entries corresponding to Net Flow Point + Quality of Service Policer for configuration purposes." + ::= { f3FpmConfigObjects 9 } + +f3NetFpQosPolicerEntry OBJECT-TYPE + SYNTAX F3NetFpQosPolicerEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A conceptual row in the f3NetFpQosPolicerTable. + These entries represent an Net Flow Point Quality + of Service Policer." + INDEX { neIndex, shelfIndex, slotIndex, cmEthernetNetPortIndex, + f3NetFlowPointIndex, f3NetFpQosPolicerIndex } + ::= { f3NetFpQosPolicerTable 1 } + +F3NetFpQosPolicerEntry ::= SEQUENCE { + f3NetFpQosPolicerIndex Integer32, + + f3NetFpQosPolicerAdminState AdminState, + f3NetFpQosPolicerOperationalState OperationalState, + f3NetFpQosPolicerSecondaryState SecondaryState, + + f3NetFpQosPolicerCIRLo Unsigned32, + f3NetFpQosPolicerCIRHi Unsigned32, + f3NetFpQosPolicerEIRLo Unsigned32, + f3NetFpQosPolicerEIRHi Unsigned32, + f3NetFpQosPolicerCBS Integer32, + f3NetFpQosPolicerEBS Integer32, + + f3NetFpQosPolicerAlgorithm PolicerAlgorithmType, + f3NetFpQosPolicerColorMode PolicerColorMode, + f3NetFpQosPolicerCouplingFlag TruthValue, + f3NetFpQosPolicerPolicingEnabled TruthValue, + + f3NetFpQosPolicerStorageType StorageType, + f3NetFpQosPolicerRowStatus RowStatus +} + +f3NetFpQosPolicerIndex OBJECT-TYPE + SYNTAX Integer32 (1..8) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The unique integer index value corresponding to a Quality + of Service Policer. + The Policer Index represents the COS level. This + is applicable in case of a Multi COS Flow Point. Index 1 + represents COS 0; Index 2 represents COS 1 and so on." + ::= { f3NetFpQosPolicerEntry 1 } + +f3NetFpQosPolicerAdminState OBJECT-TYPE + SYNTAX AdminState + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object represents the Administrative State of a Policer." + ::= { f3NetFpQosPolicerEntry 2 } + +f3NetFpQosPolicerOperationalState OBJECT-TYPE + SYNTAX OperationalState + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object represents the Operational State of a Policer." + ::= { f3NetFpQosPolicerEntry 3 } + +f3NetFpQosPolicerSecondaryState OBJECT-TYPE + SYNTAX SecondaryState + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object represents the Secondary State of a Policer." + ::= { f3NetFpQosPolicerEntry 4 } + +f3NetFpQosPolicerCIRLo OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object represents the Commited Information Rate (CIR) + (Lower 32 bits) of the Policer." + ::= { f3NetFpQosPolicerEntry 5 } + +f3NetFpQosPolicerCIRHi OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object represents the Commited Information Rate (CIR) + (Higher 32 bits) of the Policer." + ::= { f3NetFpQosPolicerEntry 6 } + +f3NetFpQosPolicerEIRLo OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object represents the Excess Information Rate (EIR) + (Lower 32 bits) of a Policer." + ::= { f3NetFpQosPolicerEntry 7 } + +f3NetFpQosPolicerEIRHi OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object represents the Excess Information Rate (EIR) + (Lower 32 bits) of a Policer." + ::= { f3NetFpQosPolicerEntry 8 } + +f3NetFpQosPolicerCBS OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object represents the Commited Burst Size (CBS) + of a Policer." + ::= { f3NetFpQosPolicerEntry 9 } + +f3NetFpQosPolicerEBS OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object represents the Excess Burst Size (EBS) + of a Policer." + ::= { f3NetFpQosPolicerEntry 10 } + +f3NetFpQosPolicerAlgorithm OBJECT-TYPE + SYNTAX PolicerAlgorithmType + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object represents Policer algorithm as 'srTCM' + (Single Rate Triple Color Marking) or 'trTCM' + (Two Rate Triple Color Marking)." + ::= { f3NetFpQosPolicerEntry 11 } + +f3NetFpQosPolicerColorMode OBJECT-TYPE + SYNTAX PolicerColorMode + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object allows specification of Policer Color Mode as + 'color-aware' or 'color-blind'." + ::= { f3NetFpQosPolicerEntry 12 } + +f3NetFpQosPolicerCouplingFlag OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object allows specification of Policer Coupling Flag. + When coupling is enabled, tokens that would normally be + added to the C-bucket are passed to the E-bucket only once the CIR + bucket has reached its CBS level. Therefore under this condition + the E-bucket is being filled at the rate of CIR + EIR. + Normally the long term average of frames declared yellow is + bounded by the EIR. Coupling is a function to allow the + long term average of frames declared yellow to be bounded by + CIR + EIR. This allows a higher volume of yellow frames + to be delivered/received if the arrival of green marked frames + is low. Tokens from the E-bucket do NOT get passed to the + C-bucket once the EBS level has been reached. + Enabling coupling in combination with a provisioned EIR of 0 + allows for a single rate three color marking (srTCM) algorithm + to be established. In this situation the E-bucket is filled at the + CIR rate in the case the C-bucket is filled to its CBS level." + ::= { f3NetFpQosPolicerEntry 13 } + +f3NetFpQosPolicerPolicingEnabled OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object allows specification of Policer Policing. + When Policing is disabled, traffic policing is bypassed. + When Policing is enabled, traffic policing is applied." + ::= { f3NetFpQosPolicerEntry 14 } + +f3NetFpQosPolicerStorageType OBJECT-TYPE + SYNTAX StorageType + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The type of storage configured for this entry." + ::= { f3NetFpQosPolicerEntry 15 } + +f3NetFpQosPolicerRowStatus OBJECT-TYPE + SYNTAX RowStatus + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The status of this row. + An entry MUST NOT exist in the active state unless all + objects in the entry have an appropriate value, as described + in the description clause for each writable object. + + The values of f3NetFpQosPolicerRowStatus supported are + createAndGo(4) and destroy(6). All mandatory attributes + must be specified in a single SNMP SET request with + f3NetFpQosPolicerRowStatus value as createAndGo(4). + Upon successful row creation, this object has a + value of active(1). + + The f3NetFpQosPolicerRowStatus object may be modified if + the associated instance of this object is equal to active(1)." + ::= { f3NetFpQosPolicerEntry 16 } + +-- +-- Net Flow Point Control Protocol Disposition +-- + +f3NetFlowPointCpdV2Table OBJECT-TYPE + SYNTAX SEQUENCE OF F3NetFlowPointCpdV2Entry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of entries corresponding to Net Flow Point + Control Protocol Disposition V2." + ::= { f3FpmConfigObjects 10 } + +f3NetFlowPointCpdV2Entry OBJECT-TYPE + SYNTAX F3NetFlowPointCpdV2Entry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A conceptual row in the f3NetFlowPointCpdV2Table. + These entries represent a Control Protocol Disposition + filtering criteria on the Net Flow Point." + INDEX { neIndex, shelfIndex, slotIndex, cmEthernetNetPortIndex, + f3NetFlowPointIndex, f3NetFlowPointCpdV2Index } + ::= { f3NetFlowPointCpdV2Table 1 } + +F3NetFlowPointCpdV2Entry ::= SEQUENCE { + f3NetFlowPointCpdV2Index Integer32, + f3NetFlowPointCpdV2IslDispType CmControlProtocolDispType, + f3NetFlowPointCpdV2PagpDispType CmControlProtocolDispType, + f3NetFlowPointCpdV2UdldDispType CmControlProtocolDispType, + f3NetFlowPointCpdV2CdpDispType CmControlProtocolDispType, + f3NetFlowPointCpdV2VtpDispType CmControlProtocolDispType, + f3NetFlowPointCpdV2DtpDispType CmControlProtocolDispType, + f3NetFlowPointCpdV2PvstpPlusDispType CmControlProtocolDispType, + f3NetFlowPointCpdV2UplinkFastDispType CmControlProtocolDispType, + f3NetFlowPointCpdV2VlanBridgeDispType CmControlProtocolDispType, + f3NetFlowPointCpdV2L2PTDispType CmControlProtocolDispType, + f3NetFlowPointCpdV2BPDUDispType CmControlProtocolDispType, + f3NetFlowPointCpdV2PauseDispType CmControlProtocolDispType, + f3NetFlowPointCpdV2LACPDispType CmControlProtocolDispType, + f3NetFlowPointCpdV2LACPMarkerDispType CmControlProtocolDispType, + f3NetFlowPointCpdV2EfmOamDispType CmControlProtocolDispType, + f3NetFlowPointCpdV2SSMDispType CmControlProtocolDispType, + f3NetFlowPointCpdV2PortAuthenDispType CmControlProtocolDispType, + f3NetFlowPointCpdV2LANBridgesDispType CmControlProtocolDispType, + f3NetFlowPointCpdV2GMRPDispType CmControlProtocolDispType, + f3NetFlowPointCpdV2GVRPDispType CmControlProtocolDispType, + f3NetFlowPointCpdV2GARPDispType CmControlProtocolDispType, + f3NetFlowPointCpdV2ActiveControlProtocols CmActiveControlProtocolsType, + f3NetFlowPointCpdV2ELMIDispType CmControlProtocolDispType, + f3NetFlowPointCpdV2Mac00DispType CmControlProtocolDispType, + f3NetFlowPointCpdV2Mac01DispType CmControlProtocolDispType, + f3NetFlowPointCpdV2Mac02DispType CmControlProtocolDispType, + f3NetFlowPointCpdV2Mac03DispType CmControlProtocolDispType, + f3NetFlowPointCpdV2Mac04DispType CmControlProtocolDispType, + f3NetFlowPointCpdV2Mac05DispType CmControlProtocolDispType, + f3NetFlowPointCpdV2Mac06DispType CmControlProtocolDispType, + f3NetFlowPointCpdV2Mac07DispType CmControlProtocolDispType, + f3NetFlowPointCpdV2Mac08DispType CmControlProtocolDispType, + f3NetFlowPointCpdV2Mac09DispType CmControlProtocolDispType, + f3NetFlowPointCpdV2Mac0ADispType CmControlProtocolDispType, + f3NetFlowPointCpdV2Mac0BDispType CmControlProtocolDispType, + f3NetFlowPointCpdV2Mac0CDispType CmControlProtocolDispType, + f3NetFlowPointCpdV2Mac0DDispType CmControlProtocolDispType, + f3NetFlowPointCpdV2Mac0EDispType CmControlProtocolDispType, + f3NetFlowPointCpdV2Mac0FDispType CmControlProtocolDispType, + f3NetFlowPointCpdV2NearestLLDPDispType CmControlProtocolDispType, + f3NetFlowPointCpdV2NonTpmrLLDPDispType CmControlProtocolDispType, + f3NetFlowPointCpdV2CustomerLLDPDispType CmControlProtocolDispType +} + +f3NetFlowPointCpdV2Index OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Unique Index value to access the CPD row." + ::= { f3NetFlowPointCpdV2Entry 1 } + +f3NetFlowPointCpdV2IslDispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Control Protocol Disposition for ISL (Inter Switch Link). + MAC Address (01:00:0C:00:00:00)." + ::= { f3NetFlowPointCpdV2Entry 2 } + +f3NetFlowPointCpdV2PagpDispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Control Protocol Disposition for PAGP (Port Aggregation Protocol). + MAC Address (01:00:0C:CC:CC:CC), Ethertype(0x104)." + ::= { f3NetFlowPointCpdV2Entry 3 } + +f3NetFlowPointCpdV2UdldDispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Control Protocol Disposition for UDLD (Unidirectional Link Detection). + MAC Address (01:00:0C:CC:CC:CC), Ethertype(0x111)." + ::= { f3NetFlowPointCpdV2Entry 4 } + +f3NetFlowPointCpdV2CdpDispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Control Protocol Disposition for CDP (Cisco Discovery Protocol). + MAC Address (01:00:0C:CC:CC:CC), Ethertype(0x2000)." + ::= { f3NetFlowPointCpdV2Entry 5 } + +f3NetFlowPointCpdV2VtpDispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Control Protocol Disposition for VTP (VLAN Trunking Protocol). + MAC Address (01:00:0C:CC:CC:CC), Ethertype(0x2003)." + ::= { f3NetFlowPointCpdV2Entry 6 } + +f3NetFlowPointCpdV2DtpDispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Control Protocol Disposition for DTP (Dynamic Trunking). + MAC Address (01:00:0C:CC:CC:CC), Ethertype(0x2004)." + ::= { f3NetFlowPointCpdV2Entry 7 } + +f3NetFlowPointCpdV2PvstpPlusDispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Control Protocol Disposition for Spanning Tree PVSTP+. + MAC Address (01:00:0C:CC:CC:CC), Ethertype(0x10B)." + ::= { f3NetFlowPointCpdV2Entry 8 } + +f3NetFlowPointCpdV2UplinkFastDispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Control Protocol Disposition for STP UplinkFast. + MAC Address (01:00:0C:CD:CD:CD), Ethertype(0x200A)." + ::= { f3NetFlowPointCpdV2Entry 9 } + +f3NetFlowPointCpdV2VlanBridgeDispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Control Protocol Disposition for VLAN Bridge. + MAC Address (01:00:0C:CD:CD:CE), Ethertype(0x10C)." + ::= { f3NetFlowPointCpdV2Entry 10 } + +f3NetFlowPointCpdV2L2PTDispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Control Protocol Disposition for Layer 2 Protocol Tunnelling(L2PT). + MAC Address (01:00:0C:CD:CD:D0)." + ::= { f3NetFlowPointCpdV2Entry 11 } + +f3NetFlowPointCpdV2BPDUDispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Control Protocol Disposition for IEEE Spanning Tree(STP), + MSTP (Multiple Spanning Tree) and RSTP (Rapid Reconfiguration of + Spanning Tree). MAC Address (01:80:C2:00:00:00)." + ::= { f3NetFlowPointCpdV2Entry 12 } + +f3NetFlowPointCpdV2PauseDispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Control Protocol Disposition for IEEE 802.3x Flow Control + (PAUSE frames)." + ::= { f3NetFlowPointCpdV2Entry 13 } + +f3NetFlowPointCpdV2LACPDispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Control Protocol Disposition for 802.3ad Link Aggregation + Protocol. + MAC Address (01:80:C2:00:00:03), Ethertype (0x8809), Subtype(01)." + ::= { f3NetFlowPointCpdV2Entry 14 } + +f3NetFlowPointCpdV2LACPMarkerDispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Control Protocol Disposition for IEEE 802.3ad Marker Protocol. + MAC Address (01:80:C2:00:00:03), Ethertype (0x8809), Subtype(02)." + ::= { f3NetFlowPointCpdV2Entry 15 } + +f3NetFlowPointCpdV2EfmOamDispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Control Protocol Disposition for IEEE 802.3ah EFM OAM. + MAC Address (01:80:C2:00:00:03), Ethertype (0x8809), Subtype(03)." + ::= { f3NetFlowPointCpdV2Entry 16 } + +f3NetFlowPointCpdV2SSMDispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Control Protocol Disposition for Sync Status Messages. + MAC Address (01:80:C2:00:00:02), Ethertype (0x19A7), Subtype(0A)." + ::= { f3NetFlowPointCpdV2Entry 17 } + +f3NetFlowPointCpdV2PortAuthenDispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Control Protocol Disposition for IEEE 802.1x Protocol. + MAC Address (01:80:C2:00:00:03), Ethertype (0x888E)." + ::= { f3NetFlowPointCpdV2Entry 18 } + +f3NetFlowPointCpdV2LANBridgesDispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Control Protocol Disposition for IEEE 802.1d LAN Bridge Managment. + MAC Address (01:80:C2:00:00:10)." + ::= { f3NetFlowPointCpdV2Entry 19 } + +f3NetFlowPointCpdV2GMRPDispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Control Protocol Disposition for GARP Multicast Registration + Protocol. MAC Address (01:80:C2:00:00:20)." + ::= { f3NetFlowPointCpdV2Entry 20 } + +f3NetFlowPointCpdV2GVRPDispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Control Protocol Disposition for GARP VLAN Registration + Protocol. MAC Address (01:80:C2:00:00:21)." + ::= { f3NetFlowPointCpdV2Entry 21 } + +f3NetFlowPointCpdV2GARPDispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Group Disposition type which includes GARP Reserved + MAC Address from range 01:80:C2:00:00:22 to 01:80:C2:00:00:2F." + ::= { f3NetFlowPointCpdV2Entry 22 } + +f3NetFlowPointCpdV2ActiveControlProtocols OBJECT-TYPE + SYNTAX CmActiveControlProtocolsType + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "List of Active Control Protocol Dispositions. Note that + if the Port Level Disposition control is set to PEER or + DISCARD, the flow level disposition is no longer active. + This object provides information on all the active + dispositions." + ::= { f3NetFlowPointCpdV2Entry 23 } + +f3NetFlowPointCpdV2ELMIDispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ELMI (Ethernet Local Management Interface) Disposition type. + MAC Address 01:80:C2:00:00:07 and EtherType of 0x88EE." + ::= { f3NetFlowPointCpdV2Entry 24 } + +f3NetFlowPointCpdV2Mac00DispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "MAC Address 01:80:C2:00:00:00 Disposition type." + ::= { f3NetFlowPointCpdV2Entry 25 } + +f3NetFlowPointCpdV2Mac01DispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "MAC Address 01:80:C2:00:00:01 Disposition type." + ::= { f3NetFlowPointCpdV2Entry 26 } + +f3NetFlowPointCpdV2Mac02DispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "MAC Address 01:80:C2:00:00:02 Disposition type." + ::= { f3NetFlowPointCpdV2Entry 27 } + +f3NetFlowPointCpdV2Mac03DispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "MAC Address 01:80:C2:00:00:03 Disposition type." + ::= { f3NetFlowPointCpdV2Entry 28 } + +f3NetFlowPointCpdV2Mac04DispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "MAC Address 01:80:C2:00:00:04 Disposition type." + ::= { f3NetFlowPointCpdV2Entry 29 } + +f3NetFlowPointCpdV2Mac05DispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "MAC Address 01:80:C2:00:00:05 Disposition type." + ::= { f3NetFlowPointCpdV2Entry 30 } + +f3NetFlowPointCpdV2Mac06DispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "MAC Address 01:80:C2:00:00:06 Disposition type." + ::= { f3NetFlowPointCpdV2Entry 31 } + +f3NetFlowPointCpdV2Mac07DispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "MAC Address 01:80:C2:00:00:07 Disposition type." + ::= { f3NetFlowPointCpdV2Entry 32 } + +f3NetFlowPointCpdV2Mac08DispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "MAC Address 01:80:C2:00:00:08 Disposition type." + ::= { f3NetFlowPointCpdV2Entry 33 } + +f3NetFlowPointCpdV2Mac09DispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "MAC Address 01:80:C2:00:00:09 Disposition type." + ::= { f3NetFlowPointCpdV2Entry 34 } + +f3NetFlowPointCpdV2Mac0ADispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "MAC Address 01:80:C2:00:00:0A Disposition type." + ::= { f3NetFlowPointCpdV2Entry 35 } + +f3NetFlowPointCpdV2Mac0BDispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "MAC Address 01:80:C2:00:00:0B Disposition type." + ::= { f3NetFlowPointCpdV2Entry 36 } + +f3NetFlowPointCpdV2Mac0CDispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "MAC Address 01:80:C2:00:00:0C Disposition type." + ::= { f3NetFlowPointCpdV2Entry 37 } + +f3NetFlowPointCpdV2Mac0DDispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "MAC Address 01:80:C2:00:00:0D Disposition type." + ::= { f3NetFlowPointCpdV2Entry 38 } + +f3NetFlowPointCpdV2Mac0EDispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "MAC Address 01:80:C2:00:00:0E Disposition type." + ::= { f3NetFlowPointCpdV2Entry 39 } + +f3NetFlowPointCpdV2Mac0FDispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "MAC Address 01:80:C2:00:00:0F Disposition type." + ::= { f3NetFlowPointCpdV2Entry 40 } + +f3NetFlowPointCpdV2NearestLLDPDispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "LLDP (Link Layer Discovery Protocol) Nearest Bridge Disposition type." + ::= { f3NetFlowPointCpdV2Entry 41 } + +f3NetFlowPointCpdV2NonTpmrLLDPDispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "LLDP (Link Layer Discovery Protocol) Non-TPMR Bridge Disposition type." + ::= { f3NetFlowPointCpdV2Entry 42 } + +f3NetFlowPointCpdV2CustomerLLDPDispType OBJECT-TYPE + SYNTAX CmControlProtocolDispType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "LLDP (Link Layer Discovery Protocol) Customer Bridge Disposition type." + ::= { f3NetFlowPointCpdV2Entry 43 } + +-- +-- Net Flowpoint table extension for Learning Control configuration +-- +f3NetFlowPointLearningConfigTable OBJECT-TYPE + SYNTAX SEQUENCE OF F3NetFlowPointLearningConfigEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table extends f3NetFlowPointTable to provide parameters for MAC Table control + configuration." + ::= { f3FpmConfigObjects 11 } + +f3NetFlowPointLearningConfigEntry OBJECT-TYPE + SYNTAX F3NetFlowPointLearningConfigEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A conceptual row in the f3NetFlowPointLearningConfigTable." + AUGMENTS { f3NetFlowPointEntry } + ::= { f3NetFlowPointLearningConfigTable 1 } + +F3NetFlowPointLearningConfigEntry ::= SEQUENCE { + f3NetFlowPointLearningConfigLearningEnabled TruthValue, + f3NetFlowPointLearningConfigMaxFwdEntries Integer32, + f3NetFlowPointLearningConfigProtectLearningCtrl ProtectLearningControl, + f3NetFlowPointLearningConfigAction FlowLearningConfigAction +} + +f3NetFlowPointLearningConfigLearningEnabled OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object allows configuring Learning Control on this Flowpoint." + ::= { f3NetFlowPointLearningConfigEntry 1 } + +f3NetFlowPointLearningConfigMaxFwdEntries OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object allows configuring the maximum number of Forwarding Entries + on this Flowpoint." + ::= { f3NetFlowPointLearningConfigEntry 2 } + +f3NetFlowPointLearningConfigProtectLearningCtrl OBJECT-TYPE + SYNTAX ProtectLearningControl + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object allows configuring Learning Control on this Flowpoint." + ::= { f3NetFlowPointLearningConfigEntry 3 } + +f3NetFlowPointLearningConfigAction OBJECT-TYPE + SYNTAX FlowLearningConfigAction + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This objects allows performing user action on Flow Learning Table." + ::= { f3NetFlowPointLearningConfigEntry 4 } + +-- +-- Access Flowpoint Current Statistics Table +-- + +f3AccFlowPointStatsTable OBJECT-TYPE + SYNTAX SEQUENCE OF F3AccFlowPointStatsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A collection of FlowPoint statistics. + These reflect the current data." + ::= { f3FpmPerfObjects 1 } + +f3AccFlowPointStatsEntry OBJECT-TYPE + SYNTAX F3AccFlowPointStatsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A conceptual row in the f3AccFlowPointStatsTable. + Entries exist in this table for each FlowPoint." + INDEX { neIndex, shelfIndex, slotIndex, cmEthernetAccPortIndex, + f3AccFlowPointIndex, f3AccFlowPointStatsIndex } + ::= { f3AccFlowPointStatsTable 1 } + +F3AccFlowPointStatsEntry ::= SEQUENCE { + f3AccFlowPointStatsIndex Integer32, + f3AccFlowPointStatsIntervalType CmPmIntervalType, + f3AccFlowPointStatsValid TruthValue, + f3AccFlowPointStatsAction CmPmBinAction, + f3AccFlowPointStatsL2CPFD PerfCounter64, + f3AccFlowPointStatsABRRx PerfCounter64, + f3AccFlowPointStatsABRRLRx PerfCounter64, + f3AccFlowPointStatsUAS PerfCounter64, + f3AccFlowPointStatsSES PerfCounter64, + f3AccFlowPointStatsFMG PerfCounter64, + f3AccFlowPointStatsFMY PerfCounter64, + f3AccFlowPointStatsFMRD PerfCounter64, + f3AccFlowPointStatsFTD PerfCounter64, + f3AccFlowPointStatsBytesIn PerfCounter64, + f3AccFlowPointStatsBytesOut PerfCounter64, + f3AccFlowPointStatsIBRMax PerfCounter64, + f3AccFlowPointStatsIBRRlMax PerfCounter64, + f3AccFlowPointStatsIBRMin PerfCounter64, + f3AccFlowPointStatsIBRRlMin PerfCounter64, + f3AccFlowPointStatsIBR PerfCounter64, + f3AccFlowPointStatsIBRRl PerfCounter64, + f3AccFlowPointStatsFBCD PerfCounter64, + f3AccFlowPointStatsFMCD PerfCounter64, + f3AccFlowPointStatsFdRxFb PerfCounter64, + f3AccFlowPointStatsFdTxFb PerfCounter64, + f3AccFlowPointStatsFdicd PerfCounter64, + f3AccFlowPointStatsNumLearnTableFlushes PerfCounter64 +} + +f3AccFlowPointStatsIndex OBJECT-TYPE + SYNTAX Integer32 (1..65535) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "An arbitrary integer index value used to uniquely identify + this Access Ethernet Flowpoint statistics entry. + Index 1 corresponds to 15minute, index 2 to 1 day and index + 3 corresponds to rollover." + ::= { f3AccFlowPointStatsEntry 1 } + +f3AccFlowPointStatsIntervalType OBJECT-TYPE + SYNTAX CmPmIntervalType + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Interval over which Performance Monitoring data is collected." + ::= { f3AccFlowPointStatsEntry 2 } + +f3AccFlowPointStatsValid OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Indicates the validity of the bin." + ::= { f3AccFlowPointStatsEntry 3 } + +f3AccFlowPointStatsAction OBJECT-TYPE + SYNTAX CmPmBinAction + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Allows the Manager to clear the bin." + ::= { f3AccFlowPointStatsEntry 4 } + +f3AccFlowPointStatsL2CPFD OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Layer 2 Control Protocol Frames Discarded." + ::= { f3AccFlowPointStatsEntry 5 } + +f3AccFlowPointStatsABRRx OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The average bit rate." + ::= { f3AccFlowPointStatsEntry 6 } + +f3AccFlowPointStatsABRRLRx OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The average bit rate, rate limited." + ::= { f3AccFlowPointStatsEntry 7 } + +f3AccFlowPointStatsUAS OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Unavailable Seconds (UAS)." + ::= { f3AccFlowPointStatsEntry 8 } + +f3AccFlowPointStatsSES OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Severely Errored Seconds (ES)." + ::= { f3AccFlowPointStatsEntry 9 } + +f3AccFlowPointStatsFMG OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Frames Marked Green." + ::= { f3AccFlowPointStatsEntry 10 } + +f3AccFlowPointStatsFMY OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Frames Marked Yellow." + ::= { f3AccFlowPointStatsEntry 11 } + +f3AccFlowPointStatsFMRD OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Frames Marked Red and Discarded." + ::= { f3AccFlowPointStatsEntry 12 } + +f3AccFlowPointStatsFTD OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Frames Tail Dropped." + ::= { f3AccFlowPointStatsEntry 13 } + +f3AccFlowPointStatsBytesIn OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Bytes In in the ingress direction." + ::= { f3AccFlowPointStatsEntry 14 } + +f3AccFlowPointStatsBytesOut OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Bytes Out in the ingress direction." + ::= { f3AccFlowPointStatsEntry 15 } + +f3AccFlowPointStatsIBRMax OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Instantaneous Bit Rate Maximum." + ::= { f3AccFlowPointStatsEntry 16 } + +f3AccFlowPointStatsIBRRlMax OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Instantaneous Bit Rate Maximum - Rate Limited." + ::= { f3AccFlowPointStatsEntry 17 } + +f3AccFlowPointStatsIBRMin OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Instantaneous Bit Rate Minimum." + ::= { f3AccFlowPointStatsEntry 18 } + +f3AccFlowPointStatsIBRRlMin OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Instantaneous Bit Rate Minimum - Rate Limited." + ::= { f3AccFlowPointStatsEntry 19 } + +f3AccFlowPointStatsIBR OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Instantaneous Bit Rate Minimum." + ::= { f3AccFlowPointStatsEntry 20 } + +f3AccFlowPointStatsIBRRl OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Instantaneous Bit Rate Minimum - Rate Limited." + ::= { f3AccFlowPointStatsEntry 21 } + +f3AccFlowPointStatsFBCD OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Frames Dropped - Broadcast Rate Limit." + ::= { f3AccFlowPointStatsEntry 22 } + +f3AccFlowPointStatsFMCD OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Frames Dropped - Multicast Rate Limit." + ::= { f3AccFlowPointStatsEntry 23 } + +f3AccFlowPointStatsFdRxFb OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Frames Dropped RX - Flowpoint Blocked." + ::= { f3AccFlowPointStatsEntry 24 } + +f3AccFlowPointStatsFdTxFb OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Frames Dropped TX - Flowpoint Blocked." + ::= { f3AccFlowPointStatsEntry 25 } + +f3AccFlowPointStatsFdicd OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Frames Dropped - Ingress COS Disabled." + ::= { f3AccFlowPointStatsEntry 26 } + +f3AccFlowPointStatsNumLearnTableFlushes OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of learning table flushes." + ::= { f3AccFlowPointStatsEntry 27 } + +-- +-- Network Flowpoint Current Statistics Table +-- + +f3NetFlowPointStatsTable OBJECT-TYPE + SYNTAX SEQUENCE OF F3NetFlowPointStatsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A collection of FlowPoint statistics. + These reflect the current data." + ::= { f3FpmPerfObjects 2 } + +f3NetFlowPointStatsEntry OBJECT-TYPE + SYNTAX F3NetFlowPointStatsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A conceptual row in the f3NetFlowPointStatsTable. + Entries exist in this table for each FlowPoint." + INDEX { neIndex, shelfIndex, slotIndex, cmEthernetNetPortIndex, + f3NetFlowPointIndex, f3NetFlowPointStatsIndex } + ::= { f3NetFlowPointStatsTable 1 } + +F3NetFlowPointStatsEntry ::= SEQUENCE { + f3NetFlowPointStatsIndex Integer32, + f3NetFlowPointStatsIntervalType CmPmIntervalType, + f3NetFlowPointStatsValid TruthValue, + f3NetFlowPointStatsAction CmPmBinAction, + f3NetFlowPointStatsL2CPFD PerfCounter64, + f3NetFlowPointStatsABRRx PerfCounter64, + f3NetFlowPointStatsABRRLRx PerfCounter64, + f3NetFlowPointStatsUAS PerfCounter64, + f3NetFlowPointStatsSES PerfCounter64, + f3NetFlowPointStatsFMG PerfCounter64, + f3NetFlowPointStatsFMY PerfCounter64, + f3NetFlowPointStatsFMRD PerfCounter64, + f3NetFlowPointStatsFTD PerfCounter64, + f3NetFlowPointStatsBytesIn PerfCounter64, + f3NetFlowPointStatsBytesOut PerfCounter64, + f3NetFlowPointStatsIBRMax PerfCounter64, + f3NetFlowPointStatsIBRRlMax PerfCounter64, + f3NetFlowPointStatsIBRMin PerfCounter64, + f3NetFlowPointStatsIBRRlMin PerfCounter64, + f3NetFlowPointStatsIBR PerfCounter64, + f3NetFlowPointStatsIBRRl PerfCounter64, + f3NetFlowPointStatsFBCD PerfCounter64, + f3NetFlowPointStatsFMCD PerfCounter64, + f3NetFlowPointStatsFdRxFb PerfCounter64, + f3NetFlowPointStatsFdTxFb PerfCounter64, + f3NetFlowPointStatsFdicd PerfCounter64, + f3NetFlowPointStatsNumLearnTableFlushes PerfCounter64 +} + +f3NetFlowPointStatsIndex OBJECT-TYPE + SYNTAX Integer32 (1..65535) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "An arbitrary integer index value used to uniquely identify + this Access Ethernet Flowpoint statistics entry. + Index 1 corresponds to 15minute, index 2 to 1 day and index + 3 corresponds to rollover." + ::= { f3NetFlowPointStatsEntry 1 } + +f3NetFlowPointStatsIntervalType OBJECT-TYPE + SYNTAX CmPmIntervalType + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Interval over which Performance Monitoring data is collected." + ::= { f3NetFlowPointStatsEntry 2 } + +f3NetFlowPointStatsValid OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Indicates the validity of the bin." + ::= { f3NetFlowPointStatsEntry 3 } + +f3NetFlowPointStatsAction OBJECT-TYPE + SYNTAX CmPmBinAction + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Allows the Manager to clear the bin." + ::= { f3NetFlowPointStatsEntry 4 } + +f3NetFlowPointStatsL2CPFD OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Layer 2 Control Protocol Frames Discarded." + ::= { f3NetFlowPointStatsEntry 5 } + +f3NetFlowPointStatsABRRx OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The average bit rate." + ::= { f3NetFlowPointStatsEntry 6 } + +f3NetFlowPointStatsABRRLRx OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The average bit rate, rate limited." + ::= { f3NetFlowPointStatsEntry 7 } + +f3NetFlowPointStatsUAS OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Unavailable Seconds (UAS)." + ::= { f3NetFlowPointStatsEntry 8 } + +f3NetFlowPointStatsSES OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Severely Errored Seconds (ES)." + ::= { f3NetFlowPointStatsEntry 9 } + +f3NetFlowPointStatsFMG OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Frames Marked Green." + ::= { f3NetFlowPointStatsEntry 10 } + +f3NetFlowPointStatsFMY OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Frames Marked Yellow." + ::= { f3NetFlowPointStatsEntry 11 } + +f3NetFlowPointStatsFMRD OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Frames Marked Red and Discarded." + ::= { f3NetFlowPointStatsEntry 12 } + +f3NetFlowPointStatsFTD OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Frames Tail Dropped." + ::= { f3NetFlowPointStatsEntry 13 } + +f3NetFlowPointStatsBytesIn OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Bytes In in the ingress direction." + ::= { f3NetFlowPointStatsEntry 14 } + +f3NetFlowPointStatsBytesOut OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Bytes Out in the ingress direction." + ::= { f3NetFlowPointStatsEntry 15 } + +f3NetFlowPointStatsIBRMax OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Instantaneous Bit Rate Maximum." + ::= { f3NetFlowPointStatsEntry 16 } + +f3NetFlowPointStatsIBRRlMax OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Instantaneous Bit Rate Maximum - Rate Limited." + ::= { f3NetFlowPointStatsEntry 17 } + +f3NetFlowPointStatsIBRMin OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Instantaneous Bit Rate Minimum." + ::= { f3NetFlowPointStatsEntry 18 } + +f3NetFlowPointStatsIBRRlMin OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Instantaneous Bit Rate Minimum - Rate Limited." + ::= { f3NetFlowPointStatsEntry 19 } + +f3NetFlowPointStatsIBR OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Instantaneous Bit Rate Minimum." + ::= { f3NetFlowPointStatsEntry 20 } + +f3NetFlowPointStatsIBRRl OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Instantaneous Bit Rate Minimum - Rate Limited." + ::= { f3NetFlowPointStatsEntry 21 } + +f3NetFlowPointStatsFBCD OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Frames Dropped - Broadcast Rate Limit." + ::= { f3NetFlowPointStatsEntry 22 } + +f3NetFlowPointStatsFMCD OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Frames Dropped - Multicast Rate Limit." + ::= { f3NetFlowPointStatsEntry 23 } + +f3NetFlowPointStatsFdRxFb OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Frames Dropped RX - Flowpoint Blocked." + ::= { f3NetFlowPointStatsEntry 24 } + +f3NetFlowPointStatsFdTxFb OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Frames Dropped TX - Flowpoint Blocked." + ::= { f3NetFlowPointStatsEntry 25 } + +f3NetFlowPointStatsFdicd OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Frames Dropped - Ingress COS Disabled." + ::= { f3NetFlowPointStatsEntry 26 } + +f3NetFlowPointStatsNumLearnTableFlushes OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of learning table flushes." + ::= { f3NetFlowPointStatsEntry 27 } + +-- +-- Access Flowpoint History Statistics Table +-- + +f3AccFlowPointHistoryTable OBJECT-TYPE + SYNTAX SEQUENCE OF F3AccFlowPointHistoryEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A collection of FlowPoint statistics. + These reflect the history data." + ::= { f3FpmPerfObjects 3 } + +f3AccFlowPointHistoryEntry OBJECT-TYPE + SYNTAX F3AccFlowPointHistoryEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A conceptual row in the f3AccFlowPointHistoryTable. + Entries exist in this table for each FlowPoint." + INDEX { neIndex, shelfIndex, slotIndex, cmEthernetAccPortIndex, + f3AccFlowPointIndex, f3AccFlowPointStatsIndex, + f3AccFlowPointHistoryIndex } + ::= { f3AccFlowPointHistoryTable 1 } + +F3AccFlowPointHistoryEntry ::= SEQUENCE { + f3AccFlowPointHistoryIndex Integer32, + f3AccFlowPointHistoryTime DateAndTime, + f3AccFlowPointHistoryValid TruthValue, + f3AccFlowPointHistoryAction CmPmBinAction, + f3AccFlowPointHistoryL2CPFD PerfCounter64, + f3AccFlowPointHistoryABRRx PerfCounter64, + f3AccFlowPointHistoryABRRLRx PerfCounter64, + f3AccFlowPointHistoryUAS PerfCounter64, + f3AccFlowPointHistorySES PerfCounter64, + f3AccFlowPointHistoryFMG PerfCounter64, + f3AccFlowPointHistoryFMY PerfCounter64, + f3AccFlowPointHistoryFMRD PerfCounter64, + f3AccFlowPointHistoryFTD PerfCounter64, + f3AccFlowPointHistoryBytesIn PerfCounter64, + f3AccFlowPointHistoryBytesOut PerfCounter64, + f3AccFlowPointHistoryIBRMax PerfCounter64, + f3AccFlowPointHistoryIBRRlMax PerfCounter64, + f3AccFlowPointHistoryIBRMin PerfCounter64, + f3AccFlowPointHistoryIBRRlMin PerfCounter64, + f3AccFlowPointHistoryIBR PerfCounter64, + f3AccFlowPointHistoryIBRRl PerfCounter64, + f3AccFlowPointHistoryFBCD PerfCounter64, + f3AccFlowPointHistoryFMCD PerfCounter64, + f3AccFlowPointHistoryFdRxFb PerfCounter64, + f3AccFlowPointHistoryFdTxFb PerfCounter64, + f3AccFlowPointHistoryFdicd PerfCounter64, + f3AccFlowPointHistoryNumLearnTableFlushes PerfCounter64 +} + +f3AccFlowPointHistoryIndex OBJECT-TYPE + SYNTAX Integer32 (1..65535) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "An arbitrary integer index value used to uniquely identify + this Access Ethernet Flowpoint History statistics entry. + Index 1 corresponds to 15minute, index 2 to 1 day and index + 3 corresponds to rollover." + ::= { f3AccFlowPointHistoryEntry 1 } + +f3AccFlowPointHistoryTime OBJECT-TYPE + SYNTAX DateAndTime + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Indicates the time of history bin creation." + ::= { f3AccFlowPointHistoryEntry 2 } + +f3AccFlowPointHistoryValid OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Indicates the validity of the bin." + ::= { f3AccFlowPointHistoryEntry 3 } + +f3AccFlowPointHistoryAction OBJECT-TYPE + SYNTAX CmPmBinAction + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Allows the Manager to clear the bin." + ::= { f3AccFlowPointHistoryEntry 4 } + +f3AccFlowPointHistoryL2CPFD OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Layer 2 Control Protocol Frames Discarded." + ::= { f3AccFlowPointHistoryEntry 5 } + +f3AccFlowPointHistoryABRRx OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The average bit rate." + ::= { f3AccFlowPointHistoryEntry 6 } + +f3AccFlowPointHistoryABRRLRx OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The average bit rate, rate limited." + ::= { f3AccFlowPointHistoryEntry 7 } + +f3AccFlowPointHistoryUAS OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Unavailable Seconds (UAS)." + ::= { f3AccFlowPointHistoryEntry 8 } + +f3AccFlowPointHistorySES OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Severely Errored Seconds (ES)." + ::= { f3AccFlowPointHistoryEntry 9 } + +f3AccFlowPointHistoryFMG OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Frames Marked Green." + ::= { f3AccFlowPointHistoryEntry 10 } + +f3AccFlowPointHistoryFMY OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Frames Marked Yellow." + ::= { f3AccFlowPointHistoryEntry 11 } + +f3AccFlowPointHistoryFMRD OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Frames Marked Red and Discarded." + ::= { f3AccFlowPointHistoryEntry 12 } + +f3AccFlowPointHistoryFTD OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Frames Tail Dropped." + ::= { f3AccFlowPointHistoryEntry 13 } + +f3AccFlowPointHistoryBytesIn OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Bytes In in the ingress direction." + ::= { f3AccFlowPointHistoryEntry 14 } + +f3AccFlowPointHistoryBytesOut OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Bytes Out in the ingress direction." + ::= { f3AccFlowPointHistoryEntry 15 } + +f3AccFlowPointHistoryIBRMax OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Instantaneous Bit Rate Maximum." + ::= { f3AccFlowPointHistoryEntry 16 } + +f3AccFlowPointHistoryIBRRlMax OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Instantaneous Bit Rate Maximum - Rate Limited." + ::= { f3AccFlowPointHistoryEntry 17 } + +f3AccFlowPointHistoryIBRMin OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Instantaneous Bit Rate Minimum." + ::= { f3AccFlowPointHistoryEntry 18 } + +f3AccFlowPointHistoryIBRRlMin OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Instantaneous Bit Rate Minimum - Rate Limited." + ::= { f3AccFlowPointHistoryEntry 19 } + +f3AccFlowPointHistoryIBR OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Instantaneous Bit Rate Minimum." + ::= { f3AccFlowPointHistoryEntry 20 } + +f3AccFlowPointHistoryIBRRl OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Instantaneous Bit Rate Minimum - Rate Limited." + ::= { f3AccFlowPointHistoryEntry 21 } + +f3AccFlowPointHistoryFBCD OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Frames Dropped - Broadcast Rate Limit." + ::= { f3AccFlowPointHistoryEntry 22 } + +f3AccFlowPointHistoryFMCD OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Frames Dropped - Multicast Rate Limit." + ::= { f3AccFlowPointHistoryEntry 23 } + +f3AccFlowPointHistoryFdRxFb OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Frames Dropped RX - Flowpoint Blocked." + ::= { f3AccFlowPointHistoryEntry 24 } + +f3AccFlowPointHistoryFdTxFb OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Frames Dropped TX - Flowpoint Blocked." + ::= { f3AccFlowPointHistoryEntry 25 } + +f3AccFlowPointHistoryFdicd OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Frames Dropped - Ingress COS Disabled." + ::= { f3AccFlowPointHistoryEntry 26 } + +f3AccFlowPointHistoryNumLearnTableFlushes OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of learning table flushes." + ::= { f3AccFlowPointHistoryEntry 27 } + +-- +-- Network Flowpoint History Statistics Table +-- + +f3NetFlowPointHistoryTable OBJECT-TYPE + SYNTAX SEQUENCE OF F3NetFlowPointHistoryEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A collection of FlowPoint statistics. + These reflect the history data." + ::= { f3FpmPerfObjects 4 } + +f3NetFlowPointHistoryEntry OBJECT-TYPE + SYNTAX F3NetFlowPointHistoryEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A conceptual row in the f3NetFlowPointHistoryTable. + Entries exist in this table for each FlowPoint." + INDEX { neIndex, shelfIndex, slotIndex, cmEthernetNetPortIndex, + f3NetFlowPointIndex, f3NetFlowPointStatsIndex, + f3NetFlowPointHistoryIndex } + ::= { f3NetFlowPointHistoryTable 1 } + +F3NetFlowPointHistoryEntry ::= SEQUENCE { + f3NetFlowPointHistoryIndex Integer32, + f3NetFlowPointHistoryTime DateAndTime, + f3NetFlowPointHistoryValid TruthValue, + f3NetFlowPointHistoryAction CmPmBinAction, + f3NetFlowPointHistoryL2CPFD PerfCounter64, + f3NetFlowPointHistoryABRRx PerfCounter64, + f3NetFlowPointHistoryABRRLRx PerfCounter64, + f3NetFlowPointHistoryUAS PerfCounter64, + f3NetFlowPointHistorySES PerfCounter64, + f3NetFlowPointHistoryFMG PerfCounter64, + f3NetFlowPointHistoryFMY PerfCounter64, + f3NetFlowPointHistoryFMRD PerfCounter64, + f3NetFlowPointHistoryFTD PerfCounter64, + f3NetFlowPointHistoryBytesIn PerfCounter64, + f3NetFlowPointHistoryBytesOut PerfCounter64, + f3NetFlowPointHistoryIBRMax PerfCounter64, + f3NetFlowPointHistoryIBRRlMax PerfCounter64, + f3NetFlowPointHistoryIBRMin PerfCounter64, + f3NetFlowPointHistoryIBRRlMin PerfCounter64, + f3NetFlowPointHistoryIBR PerfCounter64, + f3NetFlowPointHistoryIBRRl PerfCounter64, + f3NetFlowPointHistoryFBCD PerfCounter64, + f3NetFlowPointHistoryFMCD PerfCounter64, + f3NetFlowPointHistoryFdRxFb PerfCounter64, + f3NetFlowPointHistoryFdTxFb PerfCounter64, + f3NetFlowPointHistoryFdicd PerfCounter64, + f3NetFlowPointHistoryNumLearnTableFlushes PerfCounter64 +} + +f3NetFlowPointHistoryIndex OBJECT-TYPE + SYNTAX Integer32 (1..65535) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "An arbitrary integer index value used to uniquely identify + this Access Ethernet Flowpoint History statistics entry. + Index 1 corresponds to 15minute, index 2 to 1 day and index + 3 corresponds to rollover." + ::= { f3NetFlowPointHistoryEntry 1 } + +f3NetFlowPointHistoryTime OBJECT-TYPE + SYNTAX DateAndTime + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Indicates the time of history bin creation." + ::= { f3NetFlowPointHistoryEntry 2 } + +f3NetFlowPointHistoryValid OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Indicates the validity of the bin." + ::= { f3NetFlowPointHistoryEntry 3 } + +f3NetFlowPointHistoryAction OBJECT-TYPE + SYNTAX CmPmBinAction + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Allows the Manager to clear the bin." + ::= { f3NetFlowPointHistoryEntry 4 } + +f3NetFlowPointHistoryL2CPFD OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Layer 2 Control Protocol Frames Discarded." + ::= { f3NetFlowPointHistoryEntry 5 } + +f3NetFlowPointHistoryABRRx OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The average bit rate." + ::= { f3NetFlowPointHistoryEntry 6 } + +f3NetFlowPointHistoryABRRLRx OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The average bit rate, rate limited." + ::= { f3NetFlowPointHistoryEntry 7 } + +f3NetFlowPointHistoryUAS OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Unavailable Seconds (UAS)." + ::= { f3NetFlowPointHistoryEntry 8 } + +f3NetFlowPointHistorySES OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Severely Errored Seconds (ES)." + ::= { f3NetFlowPointHistoryEntry 9 } + +f3NetFlowPointHistoryFMG OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Frames Marked Green." + ::= { f3NetFlowPointHistoryEntry 10 } + +f3NetFlowPointHistoryFMY OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Frames Marked Yellow." + ::= { f3NetFlowPointHistoryEntry 11 } + +f3NetFlowPointHistoryFMRD OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Frames Marked Red and Discarded." + ::= { f3NetFlowPointHistoryEntry 12 } + +f3NetFlowPointHistoryFTD OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Frames Tail Dropped." + ::= { f3NetFlowPointHistoryEntry 13 } + +f3NetFlowPointHistoryBytesIn OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Bytes In in the ingress direction." + ::= { f3NetFlowPointHistoryEntry 14 } + +f3NetFlowPointHistoryBytesOut OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Bytes Out in the ingress direction." + ::= { f3NetFlowPointHistoryEntry 15 } + +f3NetFlowPointHistoryIBRMax OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Instantaneous Bit Rate Maximum." + ::= { f3NetFlowPointHistoryEntry 16 } + +f3NetFlowPointHistoryIBRRlMax OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Instantaneous Bit Rate Maximum - Rate Limited." + ::= { f3NetFlowPointHistoryEntry 17 } + +f3NetFlowPointHistoryIBRMin OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Instantaneous Bit Rate Minimum." + ::= { f3NetFlowPointHistoryEntry 18 } + +f3NetFlowPointHistoryIBRRlMin OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Instantaneous Bit Rate Minimum - Rate Limited." + ::= { f3NetFlowPointHistoryEntry 19 } + +f3NetFlowPointHistoryIBR OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Instantaneous Bit Rate Minimum." + ::= { f3NetFlowPointHistoryEntry 20 } + +f3NetFlowPointHistoryIBRRl OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Instantaneous Bit Rate Minimum - Rate Limited." + ::= { f3NetFlowPointHistoryEntry 21 } + +f3NetFlowPointHistoryFBCD OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Frames Dropped - Broadcast Rate Limit." + ::= { f3NetFlowPointHistoryEntry 22 } + +f3NetFlowPointHistoryFMCD OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Frames Dropped - Multicast Rate Limit." + ::= { f3NetFlowPointHistoryEntry 23 } + +f3NetFlowPointHistoryFdRxFb OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Frames Dropped RX - Flowpoint Blocked." + ::= { f3NetFlowPointHistoryEntry 24 } + +f3NetFlowPointHistoryFdTxFb OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Frames Dropped TX - Flowpoint Blocked." + ::= { f3NetFlowPointHistoryEntry 25 } + +f3NetFlowPointHistoryFdicd OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Frames Dropped - Ingress COS Disabled." + ::= { f3NetFlowPointHistoryEntry 26 } + +f3NetFlowPointHistoryNumLearnTableFlushes OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of learning table flushes." + ::= { f3NetFlowPointHistoryEntry 27 } + +-- +-- Access FlowPoint Threshold Table +-- + +f3AccFlowPointThresholdTable OBJECT-TYPE + SYNTAX SEQUENCE OF F3AccFlowPointThresholdEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table of entries that allow manageability of Agg FlowPoint Thresholds." + ::= { f3FpmPerfObjects 5 } + +f3AccFlowPointThresholdEntry OBJECT-TYPE + SYNTAX F3AccFlowPointThresholdEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A conceptual row in the f3AccFlowPointThresholdTable." + INDEX { neIndex, shelfIndex, slotIndex, cmEthernetAccPortIndex, + f3AccFlowPointIndex, f3AccFlowPointStatsIndex, f3AccFlowPointThresholdIndex } + ::= { f3AccFlowPointThresholdTable 1 } + +F3AccFlowPointThresholdEntry ::= SEQUENCE { + f3AccFlowPointThresholdIndex Integer32, + f3AccFlowPointThresholdInterval CmPmIntervalType, + f3AccFlowPointThresholdVariable VariablePointer, + f3AccFlowPointThresholdValueLo Unsigned32, + f3AccFlowPointThresholdValueHi Unsigned32, + f3AccFlowPointThresholdMonValue Counter64 +} + +f3AccFlowPointThresholdIndex OBJECT-TYPE + SYNTAX Integer32 (1..65535) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "An index that uniquely identifies an entry in the + f3AccFlowPointThresholdTable." + ::= { f3AccFlowPointThresholdEntry 1 } + +f3AccFlowPointThresholdInterval OBJECT-TYPE + SYNTAX CmPmIntervalType + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The interval over which monitored value is + sampled and compared with the specified threshold." + ::= { f3AccFlowPointThresholdEntry 2 } + +f3AccFlowPointThresholdVariable OBJECT-TYPE + SYNTAX VariablePointer + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The object identifier of the particular variable to be sampled." + ::= { f3AccFlowPointThresholdEntry 3 } + +f3AccFlowPointThresholdValueLo OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Lower 32 bits of the threshold value." + ::= { f3AccFlowPointThresholdEntry 4 } + +f3AccFlowPointThresholdValueHi OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Higher 32 bits of the threshold value." + ::= { f3AccFlowPointThresholdEntry 5 } + +f3AccFlowPointThresholdMonValue OBJECT-TYPE + SYNTAX Counter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Monitored value corresponding to f3AccFlowPointThresholdVariable." + ::= { f3AccFlowPointThresholdEntry 6 } + +-- +-- Network FlowPoint Threshold Table +-- + +f3NetFlowPointThresholdTable OBJECT-TYPE + SYNTAX SEQUENCE OF F3NetFlowPointThresholdEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table of entries that allow manageability of Agg FlowPoint Thresholds." + ::= { f3FpmPerfObjects 6 } + +f3NetFlowPointThresholdEntry OBJECT-TYPE + SYNTAX F3NetFlowPointThresholdEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A conceptual row in the f3NetFlowPointThresholdTable." + INDEX { neIndex, shelfIndex, slotIndex, cmEthernetNetPortIndex, + f3NetFlowPointIndex, f3NetFlowPointStatsIndex, f3NetFlowPointThresholdIndex } + ::= { f3NetFlowPointThresholdTable 1 } + +F3NetFlowPointThresholdEntry ::= SEQUENCE { + f3NetFlowPointThresholdIndex Integer32, + f3NetFlowPointThresholdInterval CmPmIntervalType, + f3NetFlowPointThresholdVariable VariablePointer, + f3NetFlowPointThresholdValueLo Unsigned32, + f3NetFlowPointThresholdValueHi Unsigned32, + f3NetFlowPointThresholdMonValue Counter64 +} + +f3NetFlowPointThresholdIndex OBJECT-TYPE + SYNTAX Integer32 (1..65535) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "An index that uniquely identifies an entry in the + f3NetFlowPointThresholdTable." + ::= { f3NetFlowPointThresholdEntry 1 } + +f3NetFlowPointThresholdInterval OBJECT-TYPE + SYNTAX CmPmIntervalType + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The interval over which monitored value is + sampled and compared with the specified threshold." + ::= { f3NetFlowPointThresholdEntry 2 } + +f3NetFlowPointThresholdVariable OBJECT-TYPE + SYNTAX VariablePointer + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The object identifier of the particular variable to be sampled." + ::= { f3NetFlowPointThresholdEntry 3 } + +f3NetFlowPointThresholdValueLo OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Lower 32 bits of the threshold value." + ::= { f3NetFlowPointThresholdEntry 4 } + +f3NetFlowPointThresholdValueHi OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Higher 32 bits of the threshold value." + ::= { f3NetFlowPointThresholdEntry 5 } + +f3NetFlowPointThresholdMonValue OBJECT-TYPE + SYNTAX Counter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Monitored value corresponding to f3NetFlowPointThresholdVariable." + ::= { f3NetFlowPointThresholdEntry 6 } + +-- +-- MP Flow Current Statistics Table +-- + +f3MPFlowStatsTable OBJECT-TYPE + SYNTAX SEQUENCE OF F3MPFlowStatsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A collection of MP Flow statistics. + These reflect the current data." + ::= { f3FpmPerfObjects 7 } + +f3MPFlowStatsEntry OBJECT-TYPE + SYNTAX F3MPFlowStatsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A conceptual row in the f3MPFlowStatsTable. + Entries exist in this table for each MP Flow." + INDEX { neIndex, cmMPFlowIndex, f3MPFlowStatsIndex } + ::= { f3MPFlowStatsTable 1 } + +F3MPFlowStatsEntry ::= SEQUENCE { + f3MPFlowStatsIndex Integer32, + f3MPFlowStatsIntervalType CmPmIntervalType, + f3MPFlowStatsValid TruthValue, + f3MPFlowStatsAction CmPmBinAction, + f3MPFlowStatsFDStaticBlock PerfCounter64, + f3MPFlowStatsFDHairPin PerfCounter64, + f3MPFlowStatsMacTableDiscards PerfCounter64, + f3MPFlowStatsFDProtLearn PerfCounter64 +} + +f3MPFlowStatsIndex OBJECT-TYPE + SYNTAX Integer32 (1..65535) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "An arbitrary integer index value used to uniquely identify + this MP Flow statistics entry. Index 1 corresponds to 15minute, + index 2 to 1 day and index 3 corresponds to rollover." + ::= { f3MPFlowStatsEntry 1 } + +f3MPFlowStatsIntervalType OBJECT-TYPE + SYNTAX CmPmIntervalType + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Interval over which Performance Monitoring data is collected." + ::= { f3MPFlowStatsEntry 2 } + +f3MPFlowStatsValid OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Indicates the validity of the bin." + ::= { f3MPFlowStatsEntry 3 } + +f3MPFlowStatsAction OBJECT-TYPE + SYNTAX CmPmBinAction + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Allows the Manager to clear the bin." + ::= { f3MPFlowStatsEntry 4 } + +f3MPFlowStatsFDStaticBlock OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Specifies current counter for number of frames discarded due to a + static entry in Mac Table." + ::= { f3MPFlowStatsEntry 5 } + +f3MPFlowStatsFDHairPin OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Specifies current counter for number of frames discarded because + destination Port is the ingress flowpoint or destination Port is in the + same Split Horizon Group." + ::= { f3MPFlowStatsEntry 6 } + +f3MPFlowStatsMacTableDiscards OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Specifies current counter for total number of MAC Table entries that have + been or would have been learned, but have been failed due to a lack of + storage space in the Filtering Database." + ::= { f3MPFlowStatsEntry 7 } + +f3MPFlowStatsFDProtLearn OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Specifies current counter for number + of frames dropped - protection learning." + ::= { f3MPFlowStatsEntry 8 } + +-- +-- MP Flow History Statistics Table +-- + +f3MPFlowHistoryTable OBJECT-TYPE + SYNTAX SEQUENCE OF F3MPFlowHistoryEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A collection of MP Flow statistics. + These reflect the history data." + ::= { f3FpmPerfObjects 8 } + +f3MPFlowHistoryEntry OBJECT-TYPE + SYNTAX F3MPFlowHistoryEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A conceptual row in the f3MPFlowHistoryTable. + Entries exist in this table for each MP Flow." + INDEX { neIndex, cmMPFlowIndex, f3MPFlowStatsIndex, f3MPFlowHistoryIndex } + ::= { f3MPFlowHistoryTable 1 } + +F3MPFlowHistoryEntry ::= SEQUENCE { + f3MPFlowHistoryIndex Integer32, + f3MPFlowHistoryTime DateAndTime, + f3MPFlowHistoryValid TruthValue, + f3MPFlowHistoryAction CmPmBinAction, + f3MPFlowHistoryFDStaticBlock PerfCounter64, + f3MPFlowHistoryFDHairPin PerfCounter64, + f3MPFlowHistoryMacTableDiscards PerfCounter64, + f3MPFlowHistoryFDProtLearn PerfCounter64 +} + +f3MPFlowHistoryIndex OBJECT-TYPE + SYNTAX Integer32 (1..65535) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "An arbitrary integer index value used to uniquely identify + this MP Flow History statistics entry. Index 1 corresponds to 15minute, + index 2 to 1 day and index 3 corresponds to rollover." + ::= { f3MPFlowHistoryEntry 1 } + +f3MPFlowHistoryTime OBJECT-TYPE + SYNTAX DateAndTime + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Indicates the time of history bin creation." + ::= { f3MPFlowHistoryEntry 2 } + +f3MPFlowHistoryValid OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Indicates the validity of the bin." + ::= { f3MPFlowHistoryEntry 3 } + +f3MPFlowHistoryAction OBJECT-TYPE + SYNTAX CmPmBinAction + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Allows the Manager to clear the bin." + ::= { f3MPFlowHistoryEntry 4 } + +f3MPFlowHistoryFDStaticBlock OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Specifies history bin for number of frames discarded due to a + static entry in Mac Table." + ::= { f3MPFlowHistoryEntry 5 } + +f3MPFlowHistoryFDHairPin OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Specifies history bin for number of frames discarded because + destination Port is the ingress flowpoint or destination Port is in the + same Split Horizon Group." + ::= { f3MPFlowHistoryEntry 6 } + +f3MPFlowHistoryMacTableDiscards OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Specifies history bin for total number of MAC Table entries that have + been or would have been learned, but have been failed due to a lack of + storage space in the Filtering Database." + ::= { f3MPFlowHistoryEntry 7 } + +f3MPFlowHistoryFDProtLearn OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Specifies history bin for total number + of frames dropped - protection learning." + ::= { f3MPFlowHistoryEntry 8 } + +-- +-- MP Flow Threshold Table +-- + +f3MPFlowThresholdTable OBJECT-TYPE + SYNTAX SEQUENCE OF F3MPFlowThresholdEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table of entries that allow manageability of MP Flow Thresholds." + ::= { f3FpmPerfObjects 9 } + +f3MPFlowThresholdEntry OBJECT-TYPE + SYNTAX F3MPFlowThresholdEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A conceptual row in the f3MPFlowThresholdTable." + INDEX { neIndex, cmMPFlowIndex, f3MPFlowStatsIndex, f3MPFlowThresholdIndex } + ::= { f3MPFlowThresholdTable 1 } + +F3MPFlowThresholdEntry ::= SEQUENCE { + f3MPFlowThresholdIndex Integer32, + f3MPFlowThresholdInterval CmPmIntervalType, + f3MPFlowThresholdVariable VariablePointer, + f3MPFlowThresholdValueLo Unsigned32, + f3MPFlowThresholdValueHi Unsigned32, + f3MPFlowThresholdMonValue Counter64 +} + +f3MPFlowThresholdIndex OBJECT-TYPE + SYNTAX Integer32 (1..65535) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "An index that uniquely identifies an entry in the + f3MPFlowThresholdTable." + ::= { f3MPFlowThresholdEntry 1 } + +f3MPFlowThresholdInterval OBJECT-TYPE + SYNTAX CmPmIntervalType + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The interval over which monitored value is + sampled and compared with the specified threshold." + ::= { f3MPFlowThresholdEntry 2 } + +f3MPFlowThresholdVariable OBJECT-TYPE + SYNTAX VariablePointer + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The object identifier of the particular variable to be sampled." + ::= { f3MPFlowThresholdEntry 3 } + +f3MPFlowThresholdValueLo OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Lower 32 bits of the threshold value." + ::= { f3MPFlowThresholdEntry 4 } + +f3MPFlowThresholdValueHi OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Higher 32 bits of the threshold value." + ::= { f3MPFlowThresholdEntry 5 } + +f3MPFlowThresholdMonValue OBJECT-TYPE + SYNTAX Counter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Monitored value corresponding to f3MPFlowThresholdVariable." + ::= { f3MPFlowThresholdEntry 6 } + +-- +-- Access Flow Point QoS Shaper Current Statistics Table +-- + +f3AccFpQosShaperStatsTable OBJECT-TYPE + SYNTAX SEQUENCE OF F3AccFpQosShaperStatsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A collection of Acc FlowPoint QOS Shaper statistics. + These reflect the current data." + ::= { f3FpmPerfObjects 10 } + +f3AccFpQosShaperStatsEntry OBJECT-TYPE + SYNTAX F3AccFpQosShaperStatsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A conceptual row in the f3AccFpQosShaperStatsTable. + Entries exist in this table for each FlowPoint QoS Shaper." + INDEX { neIndex, shelfIndex, slotIndex, cmEthernetAccPortIndex, + f3AccFlowPointIndex, f3AccFpQosShaperIndex, + f3AccFpQosShaperStatsIndex } + ::= { f3AccFpQosShaperStatsTable 1 } + +F3AccFpQosShaperStatsEntry ::= SEQUENCE { + f3AccFpQosShaperStatsIndex Integer32, + f3AccFpQosShaperStatsIntervalType CmPmIntervalType, + f3AccFpQosShaperStatsValid TruthValue, + f3AccFpQosShaperStatsAction CmPmBinAction, + f3AccFpQosShaperStatsBT PerfCounter64, + f3AccFpQosShaperStatsBTD PerfCounter64, + f3AccFpQosShaperStatsFD PerfCounter64, + f3AccFpQosShaperStatsFTD PerfCounter64, + f3AccFpQosShaperStatsABRRL PerfCounter64, + f3AccFpQosShaperStatsBREDD PerfCounter64, + f3AccFpQosShaperStatsFREDD PerfCounter64 +} + +f3AccFpQosShaperStatsIndex OBJECT-TYPE + SYNTAX Integer32 (1..65535) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "An arbitrary integer index value used to uniquely identify + this QOS Shaper statistics entry. + 1 - 15min + 2 - 1day + 3 - rollover + 4 - 5min" + ::= { f3AccFpQosShaperStatsEntry 1 } + +f3AccFpQosShaperStatsIntervalType OBJECT-TYPE + SYNTAX CmPmIntervalType + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Interval over which Performance Monitoring data is collected." + ::= { f3AccFpQosShaperStatsEntry 2 } + +f3AccFpQosShaperStatsValid OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Indicates the validity of the bin." + ::= { f3AccFpQosShaperStatsEntry 3 } + +f3AccFpQosShaperStatsAction OBJECT-TYPE + SYNTAX CmPmBinAction + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Allows the Manager to clear the bin." + ::= { f3AccFpQosShaperStatsEntry 4 } + +f3AccFpQosShaperStatsBT OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Bytes Transmitted." + ::= { f3AccFpQosShaperStatsEntry 5 } + +f3AccFpQosShaperStatsBTD OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Bytes Tail Dropped." + ::= { f3AccFpQosShaperStatsEntry 6 } + +f3AccFpQosShaperStatsFD OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Frames Dequeued." + ::= { f3AccFpQosShaperStatsEntry 7 } + +f3AccFpQosShaperStatsFTD OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Frames Tail Dropped." + ::= { f3AccFpQosShaperStatsEntry 8 } + +f3AccFpQosShaperStatsABRRL OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Average Bit Rate - Rate Limited." + ::= { f3AccFpQosShaperStatsEntry 9 } + +f3AccFpQosShaperStatsBREDD OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Bytes Random Early Discard, Dropped." + ::= { f3AccFpQosShaperStatsEntry 10 } + +f3AccFpQosShaperStatsFREDD OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Frames Random Early Discard, Dropped." + ::= { f3AccFpQosShaperStatsEntry 11 } + +-- +-- Access Flow Point QoS Shaper History Statistics Table +-- + +f3AccFpQosShaperHistoryTable OBJECT-TYPE + SYNTAX SEQUENCE OF F3AccFpQosShaperHistoryEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A collection of Acc FlowPoint QOS Shaper statistics. + These reflect the history data." + ::= { f3FpmPerfObjects 11 } + +f3AccFpQosShaperHistoryEntry OBJECT-TYPE + SYNTAX F3AccFpQosShaperHistoryEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A conceptual row in the f3AccFpQosShaperHistoryTable. + Entries exist in this table for each FlowPoint QoS Shaper." + INDEX { neIndex, shelfIndex, slotIndex, cmEthernetAccPortIndex, + f3AccFlowPointIndex, f3AccFpQosShaperIndex, + f3AccFpQosShaperStatsIndex, f3AccFpQosShaperHistoryIndex } + ::= { f3AccFpQosShaperHistoryTable 1 } + +F3AccFpQosShaperHistoryEntry ::= SEQUENCE { + f3AccFpQosShaperHistoryIndex Integer32, + f3AccFpQosShaperHistoryTime DateAndTime, + f3AccFpQosShaperHistoryValid TruthValue, + f3AccFpQosShaperHistoryAction CmPmBinAction, + f3AccFpQosShaperHistoryBT PerfCounter64, + f3AccFpQosShaperHistoryBTD PerfCounter64, + f3AccFpQosShaperHistoryFD PerfCounter64, + f3AccFpQosShaperHistoryFTD PerfCounter64, + f3AccFpQosShaperHistoryABRRL PerfCounter64, + f3AccFpQosShaperHistoryBREDD PerfCounter64, + f3AccFpQosShaperHistoryFREDD PerfCounter64 +} + +f3AccFpQosShaperHistoryIndex OBJECT-TYPE + SYNTAX Integer32 (1..65535) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "An arbitrary integer index value used to uniquely identify + this QOS Shaper statistics entry." + ::= { f3AccFpQosShaperHistoryEntry 1 } + +f3AccFpQosShaperHistoryTime OBJECT-TYPE + SYNTAX DateAndTime + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Indicates the time of history bin creation." + ::= { f3AccFpQosShaperHistoryEntry 2 } + +f3AccFpQosShaperHistoryValid OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Indicates the validity of the bin." + ::= { f3AccFpQosShaperHistoryEntry 3 } + +f3AccFpQosShaperHistoryAction OBJECT-TYPE + SYNTAX CmPmBinAction + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Allows the Manager to clear the bin." + ::= { f3AccFpQosShaperHistoryEntry 4 } + +f3AccFpQosShaperHistoryBT OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Bytes Transmitted." + ::= { f3AccFpQosShaperHistoryEntry 5 } + +f3AccFpQosShaperHistoryBTD OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Bytes Tail Dropped." + ::= { f3AccFpQosShaperHistoryEntry 6 } + +f3AccFpQosShaperHistoryFD OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Frames Dequeued." + ::= { f3AccFpQosShaperHistoryEntry 7 } + +f3AccFpQosShaperHistoryFTD OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Frames Tail Dropped." + ::= { f3AccFpQosShaperHistoryEntry 8 } + +f3AccFpQosShaperHistoryABRRL OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Average Bit Rate - Rate Limited." + ::= { f3AccFpQosShaperHistoryEntry 9 } + +f3AccFpQosShaperHistoryBREDD OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Bytes Random Early Discard, Dropped." + ::= { f3AccFpQosShaperHistoryEntry 10 } + +f3AccFpQosShaperHistoryFREDD OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Frames Random Early Discard, Dropped." + ::= { f3AccFpQosShaperHistoryEntry 11 } + +-- +-- Access Flow Point QoS Shaper Threshold Table +-- + +f3AccFpQosShaperThresholdTable OBJECT-TYPE + SYNTAX SEQUENCE OF F3AccFpQosShaperThresholdEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table of entries that allow manageability of Acc FlowPoint + QoS Shaper Thresholds." + ::= { f3FpmPerfObjects 12 } + +f3AccFpQosShaperThresholdEntry OBJECT-TYPE + SYNTAX F3AccFpQosShaperThresholdEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A conceptual row in the f3AccFpQosShaperThresholdTable." + INDEX { neIndex, shelfIndex, slotIndex, cmEthernetAccPortIndex, + f3AccFlowPointIndex, f3AccFpQosShaperIndex, + f3AccFpQosShaperStatsIndex, f3AccFpQosShaperThresholdIndex } + ::= { f3AccFpQosShaperThresholdTable 1 } + +F3AccFpQosShaperThresholdEntry ::= SEQUENCE { + f3AccFpQosShaperThresholdIndex Integer32, + f3AccFpQosShaperThresholdInterval CmPmIntervalType, + f3AccFpQosShaperThresholdVariable VariablePointer, + f3AccFpQosShaperThresholdValueLo Unsigned32, + f3AccFpQosShaperThresholdValueHi Unsigned32, + f3AccFpQosShaperThresholdMonValue Counter64 +} + +f3AccFpQosShaperThresholdIndex OBJECT-TYPE + SYNTAX Integer32 (1..65535) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "An index that uniquely identifies an entry in the + f3AccFpQosShaperThresholdTable." + ::= { f3AccFpQosShaperThresholdEntry 1 } + +f3AccFpQosShaperThresholdInterval OBJECT-TYPE + SYNTAX CmPmIntervalType + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The interval over which monitored value is + sampled and compared with the specified threshold." + ::= { f3AccFpQosShaperThresholdEntry 2 } + +f3AccFpQosShaperThresholdVariable OBJECT-TYPE + SYNTAX VariablePointer + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The object identifier of the particular variable to be + sampled." + ::= { f3AccFpQosShaperThresholdEntry 3 } + +f3AccFpQosShaperThresholdValueLo OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Lower 32 bits of the threshold value." + ::= { f3AccFpQosShaperThresholdEntry 4 } + +f3AccFpQosShaperThresholdValueHi OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Higher 32 bits of the threshold value." + ::= { f3AccFpQosShaperThresholdEntry 5 } + +f3AccFpQosShaperThresholdMonValue OBJECT-TYPE + SYNTAX Counter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Monitored value corresponding to f3AccFpQosShaperThresholdVariable." + ::= { f3AccFpQosShaperThresholdEntry 6 } + +-- +-- Network Flow Point QoS Shaper Current Statistics Table +-- + +f3NetFpQosShaperStatsTable OBJECT-TYPE + SYNTAX SEQUENCE OF F3NetFpQosShaperStatsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A collection of Net FlowPoint QOS Shaper statistics. + These reflect the current data." + ::= { f3FpmPerfObjects 13 } + +f3NetFpQosShaperStatsEntry OBJECT-TYPE + SYNTAX F3NetFpQosShaperStatsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A conceptual row in the f3NetFpQosShaperStatsTable. + Entries exist in this table for each FlowPoint QoS Shaper." + INDEX { neIndex, shelfIndex, slotIndex, cmEthernetNetPortIndex, + f3NetFlowPointIndex, f3NetFpQosShaperIndex, + f3NetFpQosShaperStatsIndex } + ::= { f3NetFpQosShaperStatsTable 1 } + +F3NetFpQosShaperStatsEntry ::= SEQUENCE { + f3NetFpQosShaperStatsIndex Integer32, + f3NetFpQosShaperStatsIntervalType CmPmIntervalType, + f3NetFpQosShaperStatsValid TruthValue, + f3NetFpQosShaperStatsAction CmPmBinAction, + f3NetFpQosShaperStatsBT PerfCounter64, + f3NetFpQosShaperStatsBTD PerfCounter64, + f3NetFpQosShaperStatsFD PerfCounter64, + f3NetFpQosShaperStatsFTD PerfCounter64, + f3NetFpQosShaperStatsABRRL PerfCounter64, + f3NetFpQosShaperStatsBREDD PerfCounter64, + f3NetFpQosShaperStatsFREDD PerfCounter64 +} + +f3NetFpQosShaperStatsIndex OBJECT-TYPE + SYNTAX Integer32 (1..65535) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "An arbitrary integer index value used to uniquely identify + this QOS Shaper statistics entry. + 1 - 15min + 2 - 1day + 3 - rollover + 4 - 5min" + ::= { f3NetFpQosShaperStatsEntry 1 } + +f3NetFpQosShaperStatsIntervalType OBJECT-TYPE + SYNTAX CmPmIntervalType + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Interval over which Performance Monitoring data is collected." + ::= { f3NetFpQosShaperStatsEntry 2 } + +f3NetFpQosShaperStatsValid OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Indicates the validity of the bin." + ::= { f3NetFpQosShaperStatsEntry 3 } + +f3NetFpQosShaperStatsAction OBJECT-TYPE + SYNTAX CmPmBinAction + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Allows the Manager to clear the bin." + ::= { f3NetFpQosShaperStatsEntry 4 } + +f3NetFpQosShaperStatsBT OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Bytes Transmitted." + ::= { f3NetFpQosShaperStatsEntry 5 } + +f3NetFpQosShaperStatsBTD OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Bytes Tail Dropped." + ::= { f3NetFpQosShaperStatsEntry 6 } + +f3NetFpQosShaperStatsFD OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Frames Dequeued." + ::= { f3NetFpQosShaperStatsEntry 7 } + +f3NetFpQosShaperStatsFTD OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Frames Tail Dropped." + ::= { f3NetFpQosShaperStatsEntry 8 } + +f3NetFpQosShaperStatsABRRL OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Average Bit Rate - Rate Limited." + ::= { f3NetFpQosShaperStatsEntry 9 } + +f3NetFpQosShaperStatsBREDD OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Bytes Random Early Discard, Dropped." + ::= { f3NetFpQosShaperStatsEntry 10 } + +f3NetFpQosShaperStatsFREDD OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Frames Random Early Discard, Dropped." + ::= { f3NetFpQosShaperStatsEntry 11 } + +-- +-- Network Flow Point QoS Shaper History Statistics Table +-- + +f3NetFpQosShaperHistoryTable OBJECT-TYPE + SYNTAX SEQUENCE OF F3NetFpQosShaperHistoryEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A collection of Net FlowPoint QOS Shaper statistics. + These reflect the history data." + ::= { f3FpmPerfObjects 14 } + +f3NetFpQosShaperHistoryEntry OBJECT-TYPE + SYNTAX F3NetFpQosShaperHistoryEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A conceptual row in the f3NetFpQosShaperHistoryTable. + Entries exist in this table for each FlowPoint QoS Shaper." + INDEX { neIndex, shelfIndex, slotIndex, cmEthernetNetPortIndex, + f3NetFlowPointIndex, f3NetFpQosShaperIndex, + f3NetFpQosShaperStatsIndex, f3NetFpQosShaperHistoryIndex } + ::= { f3NetFpQosShaperHistoryTable 1 } + +F3NetFpQosShaperHistoryEntry ::= SEQUENCE { + f3NetFpQosShaperHistoryIndex Integer32, + f3NetFpQosShaperHistoryTime DateAndTime, + f3NetFpQosShaperHistoryValid TruthValue, + f3NetFpQosShaperHistoryAction CmPmBinAction, + f3NetFpQosShaperHistoryBT PerfCounter64, + f3NetFpQosShaperHistoryBTD PerfCounter64, + f3NetFpQosShaperHistoryFD PerfCounter64, + f3NetFpQosShaperHistoryFTD PerfCounter64, + f3NetFpQosShaperHistoryABRRL PerfCounter64, + f3NetFpQosShaperHistoryBREDD PerfCounter64, + f3NetFpQosShaperHistoryFREDD PerfCounter64 +} + +f3NetFpQosShaperHistoryIndex OBJECT-TYPE + SYNTAX Integer32 (1..65535) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "An arbitrary integer index value used to uniquely identify + this QOS Shaper statistics entry." + ::= { f3NetFpQosShaperHistoryEntry 1 } + +f3NetFpQosShaperHistoryTime OBJECT-TYPE + SYNTAX DateAndTime + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Indicates the time of history bin creation." + ::= { f3NetFpQosShaperHistoryEntry 2 } + +f3NetFpQosShaperHistoryValid OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Indicates the validity of the bin." + ::= { f3NetFpQosShaperHistoryEntry 3 } + +f3NetFpQosShaperHistoryAction OBJECT-TYPE + SYNTAX CmPmBinAction + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Allows the Manager to clear the bin." + ::= { f3NetFpQosShaperHistoryEntry 4 } + +f3NetFpQosShaperHistoryBT OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Bytes Transmitted." + ::= { f3NetFpQosShaperHistoryEntry 5 } + +f3NetFpQosShaperHistoryBTD OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Bytes Tail Dropped." + ::= { f3NetFpQosShaperHistoryEntry 6 } + +f3NetFpQosShaperHistoryFD OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Frames Dequeued." + ::= { f3NetFpQosShaperHistoryEntry 7 } + +f3NetFpQosShaperHistoryFTD OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Frames Tail Dropped." + ::= { f3NetFpQosShaperHistoryEntry 8 } + +f3NetFpQosShaperHistoryABRRL OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Average Bit Rate - Rate Limited." + ::= { f3NetFpQosShaperHistoryEntry 9 } + +f3NetFpQosShaperHistoryBREDD OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Bytes Random Early Discard, Dropped." + ::= { f3NetFpQosShaperHistoryEntry 10 } + +f3NetFpQosShaperHistoryFREDD OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Frames Random Early Discard, Dropped." + ::= { f3NetFpQosShaperHistoryEntry 11 } + +-- +-- Network Flow Point QoS Shaper Threshold Table +-- + +f3NetFpQosShaperThresholdTable OBJECT-TYPE + SYNTAX SEQUENCE OF F3NetFpQosShaperThresholdEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table of entries that allow manageability of Net FlowPoint + QoS Shaper Thresholds." + ::= { f3FpmPerfObjects 15 } + +f3NetFpQosShaperThresholdEntry OBJECT-TYPE + SYNTAX F3NetFpQosShaperThresholdEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A conceptual row in the f3NetFpQosShaperThresholdTable." + INDEX { neIndex, shelfIndex, slotIndex, cmEthernetNetPortIndex, + f3NetFlowPointIndex, f3NetFpQosShaperIndex, + f3NetFpQosShaperStatsIndex, f3NetFpQosShaperThresholdIndex } + ::= { f3NetFpQosShaperThresholdTable 1 } + +F3NetFpQosShaperThresholdEntry ::= SEQUENCE { + f3NetFpQosShaperThresholdIndex Integer32, + f3NetFpQosShaperThresholdInterval CmPmIntervalType, + f3NetFpQosShaperThresholdVariable VariablePointer, + f3NetFpQosShaperThresholdValueLo Unsigned32, + f3NetFpQosShaperThresholdValueHi Unsigned32, + f3NetFpQosShaperThresholdMonValue Counter64 +} + +f3NetFpQosShaperThresholdIndex OBJECT-TYPE + SYNTAX Integer32 (1..65535) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "An index that uniquely identifies an entry in the + f3NetFpQosShaperThresholdTable." + ::= { f3NetFpQosShaperThresholdEntry 1 } + +f3NetFpQosShaperThresholdInterval OBJECT-TYPE + SYNTAX CmPmIntervalType + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The interval over which monitored value is + sampled and compared with the specified threshold." + ::= { f3NetFpQosShaperThresholdEntry 2 } + +f3NetFpQosShaperThresholdVariable OBJECT-TYPE + SYNTAX VariablePointer + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The object identifier of the particular variable to be + sampled." + ::= { f3NetFpQosShaperThresholdEntry 3 } + +f3NetFpQosShaperThresholdValueLo OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Lower 32 bits of the threshold value." + ::= { f3NetFpQosShaperThresholdEntry 4 } + +f3NetFpQosShaperThresholdValueHi OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Higher 32 bits of the threshold value." + ::= { f3NetFpQosShaperThresholdEntry 5 } + +f3NetFpQosShaperThresholdMonValue OBJECT-TYPE + SYNTAX Counter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Monitored value corresponding to f3NetFpQosShaperThresholdVariable." + ::= { f3NetFpQosShaperThresholdEntry 6 } + +-- +-- Access Flow Point QoS Policer Current Statistics Table +-- + +f3AccFpQosPolicerStatsTable OBJECT-TYPE + SYNTAX SEQUENCE OF F3AccFpQosPolicerStatsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A collection of Acc FlowPoint QOS Policer statistics. + These reflect the current data." + ::= { f3FpmPerfObjects 16 } + +f3AccFpQosPolicerStatsEntry OBJECT-TYPE + SYNTAX F3AccFpQosPolicerStatsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A conceptual row in the f3AccFpQosPolicerStatsTable. + Entries exist in this table for each Acc FlowPoint QoS Policer." + INDEX { neIndex, shelfIndex, slotIndex, cmEthernetAccPortIndex, + f3AccFlowPointIndex, f3AccFpQosPolicerIndex, f3AccFpQosPolicerStatsIndex } + ::= { f3AccFpQosPolicerStatsTable 1 } + +F3AccFpQosPolicerStatsEntry ::= SEQUENCE { + f3AccFpQosPolicerStatsIndex Integer32, + f3AccFpQosPolicerStatsIntervalType CmPmIntervalType, + f3AccFpQosPolicerStatsValid TruthValue, + f3AccFpQosPolicerStatsAction CmPmBinAction, + f3AccFpQosPolicerStatsFMG PerfCounter64, + f3AccFpQosPolicerStatsFMY PerfCounter64, + f3AccFpQosPolicerStatsFMRD PerfCounter64, + f3AccFpQosPolicerStatsBytesIn PerfCounter64, + f3AccFpQosPolicerStatsBytesOut PerfCounter64, + f3AccFpQosPolicerStatsABR PerfCounter64 +} + +f3AccFpQosPolicerStatsIndex OBJECT-TYPE + SYNTAX Integer32 (1..65535) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "An integer index value used to uniquely identify + this QOS Policer statistics entry. + 1 - 15min + 2 - 1day + 3 - rollover + 4 - 5min" + ::= { f3AccFpQosPolicerStatsEntry 1 } + +f3AccFpQosPolicerStatsIntervalType OBJECT-TYPE + SYNTAX CmPmIntervalType + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Interval over which Performance Monitoring data is collected." + ::= { f3AccFpQosPolicerStatsEntry 2 } + +f3AccFpQosPolicerStatsValid OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Indicates the validity of the bin." + ::= { f3AccFpQosPolicerStatsEntry 3 } + +f3AccFpQosPolicerStatsAction OBJECT-TYPE + SYNTAX CmPmBinAction + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Allows the Manager to clear the bin." + ::= { f3AccFpQosPolicerStatsEntry 4 } + +f3AccFpQosPolicerStatsFMG OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Frames Marked Green." + ::= { f3AccFpQosPolicerStatsEntry 5 } + +f3AccFpQosPolicerStatsFMY OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Frames Marked Yellow." + ::= { f3AccFpQosPolicerStatsEntry 6 } + +f3AccFpQosPolicerStatsFMRD OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Frames Marked Red and Discarded." + ::= { f3AccFpQosPolicerStatsEntry 7 } + +f3AccFpQosPolicerStatsBytesIn OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of bytes received by the Policer." + ::= { f3AccFpQosPolicerStatsEntry 8 } + +f3AccFpQosPolicerStatsBytesOut OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of bytes transmitted by the Policer." + ::= { f3AccFpQosPolicerStatsEntry 9 } + +f3AccFpQosPolicerStatsABR OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Average Bit Rate on the Policer." + ::= { f3AccFpQosPolicerStatsEntry 10 } + +-- +-- Access Flow Point QoS Policer History Statistics Table +-- + +f3AccFpQosPolicerHistoryTable OBJECT-TYPE + SYNTAX SEQUENCE OF F3AccFpQosPolicerHistoryEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A collection of Acc FlowPoint QOS Policer statistics. + These reflect the history data." + ::= { f3FpmPerfObjects 17 } + +f3AccFpQosPolicerHistoryEntry OBJECT-TYPE + SYNTAX F3AccFpQosPolicerHistoryEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A conceptual row in the f3AccFpQosPolicerHistoryTable. + Entries exist in this table for each Acc FlowPoint QoS Policer." + INDEX { neIndex, shelfIndex, slotIndex, cmEthernetAccPortIndex, + f3AccFlowPointIndex, f3AccFpQosPolicerIndex, + f3AccFpQosPolicerStatsIndex, f3AccFpQosPolicerHistoryIndex } + ::= { f3AccFpQosPolicerHistoryTable 1 } + +F3AccFpQosPolicerHistoryEntry ::= SEQUENCE { + f3AccFpQosPolicerHistoryIndex Integer32, + f3AccFpQosPolicerHistoryTime DateAndTime, + f3AccFpQosPolicerHistoryValid TruthValue, + f3AccFpQosPolicerHistoryAction CmPmBinAction, + f3AccFpQosPolicerHistoryFMG PerfCounter64, + f3AccFpQosPolicerHistoryFMY PerfCounter64, + f3AccFpQosPolicerHistoryFMRD PerfCounter64, + f3AccFpQosPolicerHistoryBytesIn PerfCounter64, + f3AccFpQosPolicerHistoryBytesOut PerfCounter64, + f3AccFpQosPolicerHistoryABR PerfCounter64 +} + +f3AccFpQosPolicerHistoryIndex OBJECT-TYPE + SYNTAX Integer32 (1..65535) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "An arbitrary integer index value used to uniquely identify + this QOS Policer history entry." + ::= { f3AccFpQosPolicerHistoryEntry 1 } + +f3AccFpQosPolicerHistoryTime OBJECT-TYPE + SYNTAX DateAndTime + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Indicates the time of history bin creation." + ::= { f3AccFpQosPolicerHistoryEntry 2 } + +f3AccFpQosPolicerHistoryValid OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Indicates the validity of the bin." + ::= { f3AccFpQosPolicerHistoryEntry 3 } + +f3AccFpQosPolicerHistoryAction OBJECT-TYPE + SYNTAX CmPmBinAction + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Allows the Manager to clear the bin." + ::= { f3AccFpQosPolicerHistoryEntry 4 } + +f3AccFpQosPolicerHistoryFMG OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Frames Marked Green." + ::= { f3AccFpQosPolicerHistoryEntry 5 } + +f3AccFpQosPolicerHistoryFMY OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Frames Marked Yellow." + ::= { f3AccFpQosPolicerHistoryEntry 6 } + +f3AccFpQosPolicerHistoryFMRD OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Frames Marked Red and Discarded." + ::= { f3AccFpQosPolicerHistoryEntry 7 } + +f3AccFpQosPolicerHistoryBytesIn OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of bytes received by the Policer." + ::= { f3AccFpQosPolicerHistoryEntry 8 } + +f3AccFpQosPolicerHistoryBytesOut OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of bytes transmitted by the Policer." + ::= { f3AccFpQosPolicerHistoryEntry 9 } + +f3AccFpQosPolicerHistoryABR OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Average Bit Rate on the Policer." + ::= { f3AccFpQosPolicerHistoryEntry 10 } + +-- +-- Access Flow Point QoS Policer Threshold Table +-- + +f3AccFpQosPolicerThresholdTable OBJECT-TYPE + SYNTAX SEQUENCE OF F3AccFpQosPolicerThresholdEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table of entries that allow manageability of QOS + Policer Thresholds." + ::= { f3FpmPerfObjects 18 } + +f3AccFpQosPolicerThresholdEntry OBJECT-TYPE + SYNTAX F3AccFpQosPolicerThresholdEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A conceptual row in the f3AccFpQosPolicerThresholdTable." + INDEX { neIndex, shelfIndex, slotIndex, cmEthernetAccPortIndex, + f3AccFlowPointIndex, f3AccFpQosPolicerIndex, + f3AccFpQosPolicerStatsIndex, f3AccFpQosPolicerThresholdIndex } + ::= { f3AccFpQosPolicerThresholdTable 1 } + +F3AccFpQosPolicerThresholdEntry ::= SEQUENCE { + f3AccFpQosPolicerThresholdIndex Integer32, + f3AccFpQosPolicerThresholdInterval CmPmIntervalType, + f3AccFpQosPolicerThresholdVariable VariablePointer, + f3AccFpQosPolicerThresholdValueLo Unsigned32, + f3AccFpQosPolicerThresholdValueHi Unsigned32, + f3AccFpQosPolicerThresholdMonValue Counter64 +} + +f3AccFpQosPolicerThresholdIndex OBJECT-TYPE + SYNTAX Integer32 (1..65535) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "An index that uniquely identifies an entry in the + f3AccFpQosPolicerThresholdTable." + ::= { f3AccFpQosPolicerThresholdEntry 1 } + +f3AccFpQosPolicerThresholdInterval OBJECT-TYPE + SYNTAX CmPmIntervalType + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The interval over which monitored value is + sampled and compared with the specified threshold." + ::= { f3AccFpQosPolicerThresholdEntry 2 } + +f3AccFpQosPolicerThresholdVariable OBJECT-TYPE + SYNTAX VariablePointer + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The object identifier of the particular variable to be + sampled." + ::= { f3AccFpQosPolicerThresholdEntry 3 } + +f3AccFpQosPolicerThresholdValueLo OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Lower 32 bits of the threshold value." + ::= { f3AccFpQosPolicerThresholdEntry 4 } + +f3AccFpQosPolicerThresholdValueHi OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Higher 32 bits of the threshold value." + ::= { f3AccFpQosPolicerThresholdEntry 5 } + +f3AccFpQosPolicerThresholdMonValue OBJECT-TYPE + SYNTAX Counter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Monitored value corresponding to f3AccFpQosPolicerThresholdVariable." + ::= { f3AccFpQosPolicerThresholdEntry 6 } + +-- +-- Network Flow Point QoS Policer Current Statistics Table +-- + +f3NetFpQosPolicerStatsTable OBJECT-TYPE + SYNTAX SEQUENCE OF F3NetFpQosPolicerStatsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A collection of Net FlowPoint QOS Policer statistics. + These reflect the current data." + ::= { f3FpmPerfObjects 19 } + +f3NetFpQosPolicerStatsEntry OBJECT-TYPE + SYNTAX F3NetFpQosPolicerStatsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A conceptual row in the f3NetFpQosPolicerStatsTable. + Entries exist in this table for each Net FlowPoint QoS Policer." + INDEX { neIndex, shelfIndex, slotIndex, cmEthernetNetPortIndex, + f3NetFlowPointIndex, f3NetFpQosPolicerIndex, f3NetFpQosPolicerStatsIndex } + ::= { f3NetFpQosPolicerStatsTable 1 } + +F3NetFpQosPolicerStatsEntry ::= SEQUENCE { + f3NetFpQosPolicerStatsIndex Integer32, + f3NetFpQosPolicerStatsIntervalType CmPmIntervalType, + f3NetFpQosPolicerStatsValid TruthValue, + f3NetFpQosPolicerStatsAction CmPmBinAction, + f3NetFpQosPolicerStatsFMG PerfCounter64, + f3NetFpQosPolicerStatsFMY PerfCounter64, + f3NetFpQosPolicerStatsFMRD PerfCounter64, + f3NetFpQosPolicerStatsBytesIn PerfCounter64, + f3NetFpQosPolicerStatsBytesOut PerfCounter64, + f3NetFpQosPolicerStatsABR PerfCounter64 +} + +f3NetFpQosPolicerStatsIndex OBJECT-TYPE + SYNTAX Integer32 (1..65535) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "An integer index value used to uniquely identify + this QOS Policer statistics entry. + 1 - 15min + 2 - 1day + 3 - rollover + 4 - 5min" + ::= { f3NetFpQosPolicerStatsEntry 1 } + +f3NetFpQosPolicerStatsIntervalType OBJECT-TYPE + SYNTAX CmPmIntervalType + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Interval over which Performance Monitoring data is collected." + ::= { f3NetFpQosPolicerStatsEntry 2 } + +f3NetFpQosPolicerStatsValid OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Indicates the validity of the bin." + ::= { f3NetFpQosPolicerStatsEntry 3 } + +f3NetFpQosPolicerStatsAction OBJECT-TYPE + SYNTAX CmPmBinAction + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Allows the Manager to clear the bin." + ::= { f3NetFpQosPolicerStatsEntry 4 } + +f3NetFpQosPolicerStatsFMG OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Frames Marked Green." + ::= { f3NetFpQosPolicerStatsEntry 5 } + +f3NetFpQosPolicerStatsFMY OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Frames Marked Yellow." + ::= { f3NetFpQosPolicerStatsEntry 6 } + +f3NetFpQosPolicerStatsFMRD OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Frames Marked Red and Discarded." + ::= { f3NetFpQosPolicerStatsEntry 7 } + +f3NetFpQosPolicerStatsBytesIn OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of bytes received by the Policer." + ::= { f3NetFpQosPolicerStatsEntry 8 } + +f3NetFpQosPolicerStatsBytesOut OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of bytes transmitted by the Policer." + ::= { f3NetFpQosPolicerStatsEntry 9 } + +f3NetFpQosPolicerStatsABR OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Average Bit Rate on the Policer." + ::= { f3NetFpQosPolicerStatsEntry 10 } + +-- +-- Network Flow Point QoS Policer History Statistics Table +-- + +f3NetFpQosPolicerHistoryTable OBJECT-TYPE + SYNTAX SEQUENCE OF F3NetFpQosPolicerHistoryEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A collection of Net FlowPoint QOS Policer statistics. + These reflect the history data." + ::= { f3FpmPerfObjects 20 } + +f3NetFpQosPolicerHistoryEntry OBJECT-TYPE + SYNTAX F3NetFpQosPolicerHistoryEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A conceptual row in the f3NetFpQosPolicerHistoryTable. + Entries exist in this table for each Net FlowPoint QoS Policer." + INDEX { neIndex, shelfIndex, slotIndex, cmEthernetNetPortIndex, + f3NetFlowPointIndex, f3NetFpQosPolicerIndex, + f3NetFpQosPolicerStatsIndex, f3NetFpQosPolicerHistoryIndex } + ::= { f3NetFpQosPolicerHistoryTable 1 } + +F3NetFpQosPolicerHistoryEntry ::= SEQUENCE { + f3NetFpQosPolicerHistoryIndex Integer32, + f3NetFpQosPolicerHistoryTime DateAndTime, + f3NetFpQosPolicerHistoryValid TruthValue, + f3NetFpQosPolicerHistoryAction CmPmBinAction, + f3NetFpQosPolicerHistoryFMG PerfCounter64, + f3NetFpQosPolicerHistoryFMY PerfCounter64, + f3NetFpQosPolicerHistoryFMRD PerfCounter64, + f3NetFpQosPolicerHistoryBytesIn PerfCounter64, + f3NetFpQosPolicerHistoryBytesOut PerfCounter64, + f3NetFpQosPolicerHistoryABR PerfCounter64 +} + +f3NetFpQosPolicerHistoryIndex OBJECT-TYPE + SYNTAX Integer32 (1..65535) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "An arbitrary integer index value used to uniquely identify + this QOS Policer history entry." + ::= { f3NetFpQosPolicerHistoryEntry 1 } + +f3NetFpQosPolicerHistoryTime OBJECT-TYPE + SYNTAX DateAndTime + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Indicates the time of history bin creation." + ::= { f3NetFpQosPolicerHistoryEntry 2 } + +f3NetFpQosPolicerHistoryValid OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Indicates the validity of the bin." + ::= { f3NetFpQosPolicerHistoryEntry 3 } + +f3NetFpQosPolicerHistoryAction OBJECT-TYPE + SYNTAX CmPmBinAction + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Allows the Manager to clear the bin." + ::= { f3NetFpQosPolicerHistoryEntry 4 } + +f3NetFpQosPolicerHistoryFMG OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Frames Marked Green." + ::= { f3NetFpQosPolicerHistoryEntry 5 } + +f3NetFpQosPolicerHistoryFMY OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Frames Marked Yellow." + ::= { f3NetFpQosPolicerHistoryEntry 6 } + +f3NetFpQosPolicerHistoryFMRD OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Frames Marked Red and Discarded." + ::= { f3NetFpQosPolicerHistoryEntry 7 } + +f3NetFpQosPolicerHistoryBytesIn OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of bytes received by the Policer." + ::= { f3NetFpQosPolicerHistoryEntry 8 } + +f3NetFpQosPolicerHistoryBytesOut OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of bytes transmitted by the Policer." + ::= { f3NetFpQosPolicerHistoryEntry 9 } + +f3NetFpQosPolicerHistoryABR OBJECT-TYPE + SYNTAX PerfCounter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Average Bit Rate on the Policer." + ::= { f3NetFpQosPolicerHistoryEntry 10 } + +-- +-- Network Flow Point QoS Policer Threshold Table +-- + +f3NetFpQosPolicerThresholdTable OBJECT-TYPE + SYNTAX SEQUENCE OF F3NetFpQosPolicerThresholdEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table of entries that allow manageability of QOS + Policer Thresholds." + ::= { f3FpmPerfObjects 21 } + +f3NetFpQosPolicerThresholdEntry OBJECT-TYPE + SYNTAX F3NetFpQosPolicerThresholdEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A conceptual row in the f3NetFpQosPolicerThresholdTable." + INDEX { neIndex, shelfIndex, slotIndex, cmEthernetNetPortIndex, + f3NetFlowPointIndex, f3NetFpQosPolicerIndex, + f3NetFpQosPolicerStatsIndex, f3NetFpQosPolicerThresholdIndex } + ::= { f3NetFpQosPolicerThresholdTable 1 } + +F3NetFpQosPolicerThresholdEntry ::= SEQUENCE { + f3NetFpQosPolicerThresholdIndex Integer32, + f3NetFpQosPolicerThresholdInterval CmPmIntervalType, + f3NetFpQosPolicerThresholdVariable VariablePointer, + f3NetFpQosPolicerThresholdValueLo Unsigned32, + f3NetFpQosPolicerThresholdValueHi Unsigned32, + f3NetFpQosPolicerThresholdMonValue Counter64 +} + +f3NetFpQosPolicerThresholdIndex OBJECT-TYPE + SYNTAX Integer32 (1..65535) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "An index that uniquely identifies an entry in the + f3NetFpQosPolicerThresholdTable." + ::= { f3NetFpQosPolicerThresholdEntry 1 } + +f3NetFpQosPolicerThresholdInterval OBJECT-TYPE + SYNTAX CmPmIntervalType + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The interval over which monitored value is + sampled and compared with the specified threshold." + ::= { f3NetFpQosPolicerThresholdEntry 2 } + +f3NetFpQosPolicerThresholdVariable OBJECT-TYPE + SYNTAX VariablePointer + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The object identifier of the particular variable to be + sampled." + ::= { f3NetFpQosPolicerThresholdEntry 3 } + +f3NetFpQosPolicerThresholdValueLo OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Lower 32 bits of the threshold value." + ::= { f3NetFpQosPolicerThresholdEntry 4 } + +f3NetFpQosPolicerThresholdValueHi OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Higher 32 bits of the threshold value." + ::= { f3NetFpQosPolicerThresholdEntry 5 } + +f3NetFpQosPolicerThresholdMonValue OBJECT-TYPE + SYNTAX Counter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Monitored value corresponding to f3NetFpQosPolicerThresholdVariable." + ::= { f3NetFpQosPolicerThresholdEntry 6 } + +-- +-- Notifications +-- + +f3AccFlowPointThresholdCrossingAlert NOTIFICATION-TYPE + OBJECTS { + f3AccFlowPointThresholdIndex, + f3AccFlowPointThresholdInterval, + f3AccFlowPointThresholdVariable, + f3AccFlowPointThresholdValueLo, + f3AccFlowPointThresholdValueHi, + f3AccFlowPointThresholdMonValue + } + STATUS current + DESCRIPTION + "This trap is sent each time a threshold on a PM condition + on an Ethernet Access Port FlowPoint is crossed." + ::= { f3FpmPerfNotifications 1 } + +f3NetFlowPointThresholdCrossingAlert NOTIFICATION-TYPE + OBJECTS { + f3NetFlowPointThresholdIndex, + f3NetFlowPointThresholdInterval, + f3NetFlowPointThresholdVariable, + f3NetFlowPointThresholdValueLo, + f3NetFlowPointThresholdValueHi, + f3NetFlowPointThresholdMonValue + } + STATUS current + DESCRIPTION + "This trap is sent each time a threshold on a PM condition + on an Ethernet Network Port FlowPoint is crossed." + ::= { f3FpmPerfNotifications 2 } + +f3MPFlowThresholdCrossingAlert NOTIFICATION-TYPE + OBJECTS { + f3MPFlowThresholdIndex, + f3MPFlowThresholdInterval, + f3MPFlowThresholdVariable, + f3MPFlowThresholdValueLo, + f3MPFlowThresholdValueHi, + f3MPFlowThresholdMonValue + } + STATUS current + DESCRIPTION + "This trap is sent each time a threshold on a PM condition + on an MP Flow is crossed." + ::= { f3FpmPerfNotifications 3 } + +f3AccFpQosShaperThresholdCrossingAlert NOTIFICATION-TYPE + OBJECTS { + f3AccFpQosShaperThresholdIndex, + f3AccFpQosShaperThresholdInterval, + f3AccFpQosShaperThresholdVariable, + f3AccFpQosShaperThresholdValueLo, + f3AccFpQosShaperThresholdValueHi, + f3AccFpQosShaperThresholdMonValue + } + STATUS current + DESCRIPTION + "This trap is sent each time a threshold on a PM condition + on an Acc FlowPoint QoS Shaper is crossed." + ::= { f3FpmPerfNotifications 4 } + +f3NetFpQosShaperThresholdCrossingAlert NOTIFICATION-TYPE + OBJECTS { + f3NetFpQosShaperThresholdIndex, + f3NetFpQosShaperThresholdInterval, + f3NetFpQosShaperThresholdVariable, + f3NetFpQosShaperThresholdValueLo, + f3NetFpQosShaperThresholdValueHi, + f3NetFpQosShaperThresholdMonValue + } + STATUS current + DESCRIPTION + "This trap is sent each time a threshold on a PM condition + on an Net FlowPoint QoS Shaper is crossed." + ::= { f3FpmPerfNotifications 5 } + +f3AccFpQosPolicerThresholdCrossingAlert NOTIFICATION-TYPE + OBJECTS { + f3AccFpQosPolicerThresholdIndex, + f3AccFpQosPolicerThresholdInterval, + f3AccFpQosPolicerThresholdVariable, + f3AccFpQosPolicerThresholdValueLo, + f3AccFpQosPolicerThresholdValueHi, + f3AccFpQosPolicerThresholdMonValue + } + STATUS current + DESCRIPTION + "This trap is sent each time a threshold on a PM condition + on an Acc FlowPoint QoS Policer is crossed." + ::= { f3FpmPerfNotifications 6 } + +f3NetFpQosPolicerThresholdCrossingAlert NOTIFICATION-TYPE + OBJECTS { + f3NetFpQosPolicerThresholdIndex, + f3NetFpQosPolicerThresholdInterval, + f3NetFpQosPolicerThresholdVariable, + f3NetFpQosPolicerThresholdValueLo, + f3NetFpQosPolicerThresholdValueHi, + f3NetFpQosPolicerThresholdMonValue + } + STATUS current + DESCRIPTION + "This trap is sent each time a threshold on a PM condition + on an Net FlowPoint QoS Policer is crossed." + ::= { f3FpmPerfNotifications 7 } + +-- +-- Conformance +-- + +f3FpmCompliances OBJECT IDENTIFIER ::= {f3FpmConformance 1} +f3FpmGroups OBJECT IDENTIFIER ::= {f3FpmConformance 2} + +f3FpmCompliance MODULE-COMPLIANCE + STATUS current + DESCRIPTION + "Describes the requirements for conformance to the F3-FPM-MIB compilance." + MODULE -- this module + MANDATORY-GROUPS { + f3AccFlowPointGroup, + f3AccFpQosShaperGroup, + f3AccFpQosPolicerGroup, + f3MPFlowExtGroup, + f3AccFlowPointCpdV2Group, + f3AccFlowPointLearningConfigGroup, + f3NetFlowPointGroup, + f3NetFpQosShaperGroup, + f3NetFpQosPolicerGroup, + f3NetFlowPointCpdV2Group, + f3NetFlowPointLearningConfigGroup, + f3AccFlowPointPerfGroup, + f3NetFlowPointPerfGroup, + f3MPFlowPerfGroup, + f3AccFpQosShaperPerfGroup, + f3NetFpQosShaperPerfGroup, + f3AccFpQosPolicerPerfGroup, + f3NetFpQosPolicerPerfGroup, + f3FpmPerfNotifGroup + } + ::= { f3FpmCompliances 1 } + +f3AccFlowPointGroup OBJECT-GROUP + OBJECTS { + f3AccFlowPointAlias, + f3AccFlowPointAdminState, + f3AccFlowPointOperationalState, + f3AccFlowPointSecondaryState, + f3AccFlowPointAssociatedFlowId, + f3AccFlowPointIngressMultiCOSEnabled, + f3AccFlowPointIngressCOS, + f3AccFlowPointEgressShapingType, + f3AccFlowPointIngressVlanMemberList, + f3AccFlowPointVlanMemberAction, + f3AccFlowPointVlanMemberActionVlan, + f3AccFlowPointIngressUntaggedFrameEnabled, + f3AccFlowPointCTagControl, + f3AccFlowPointCTagVlanId, + f3AccFlowPointCTagVlanPriority, + f3AccFlowPointSTagControl, + f3AccFlowPointSTagVlanId, + f3AccFlowPointSTagVlanPriority, + f3AccFlowPointEgressOuterTagPrioMapEnabled, + f3AccFlowPointEgressInnerTagPrioMapEnabled, + f3AccFlowPointSESFramesLossThresholdRatio, + f3AccFlowPointDefaultMemberEnabled, + f3AccFlowPointMcastRateLimitEnabled, + f3AccFlowPointMcastRateLimitSpeedLo, + f3AccFlowPointMcastRateLimitSpeedHi, + f3AccFlowPointBcastRateLimitEnabled, + f3AccFlowPointBcastRateLimitSpeedLo, + f3AccFlowPointBcastRateLimitSpeedHi, + f3AccFlowPointCombinedRateLimitEnabled, + f3AccFlowPointCombinedRateLimitSpeedLo, + f3AccFlowPointCombinedRateLimitSpeedHi, + f3AccFlowPointSplitHorizonGroupOID, + f3AccFlowPointLoopAvoidance, + f3AccFlowPointHierarchicalCOSEnabled, + f3AccFlowPointMaximumBWLo, + f3AccFlowPointMaximumBWHi, + f3AccFlowPointGuaranteedBWLo, + f3AccFlowPointGuaranteedBWHi, + f3AccFlowPointAutoBandwidthConfigEnabled, + f3AccFlowPointAutoCIRPercentage, + f3AccFlowPointFrameFwdEnabled, + f3AccFlowPointStorageType, + f3AccFlowPointRowStatus, + f3AccFlowPointUsePortPrioMapProfile, + f3AccFlowPointRefPrioMapProfile, + f3AccFlowpointRefConnectGuardFlowObject, + f3AccFlowpointSecureBlockingControl, + f3AccFlowpointSecureState + + } + STATUS current + DESCRIPTION + "A collection of Access Flow Point objects." + ::= { f3FpmGroups 1 } + +f3AccFpQosShaperGroup OBJECT-GROUP + OBJECTS { + f3AccFpQosShaperIndex, + f3AccFpQosShaperAdminState, + f3AccFpQosShaperOperationalState, + f3AccFpQosShaperSecondaryState, + f3AccFpQosShaperCIRLo, + f3AccFpQosShaperCIRHi, + f3AccFpQosShaperCBS, + f3AccFpQosShaperEIRLo, + f3AccFpQosShaperEIRHi, + f3AccFpQosShaperEBS, + f3AccFpQosShaperBufferSize, + f3AccFpQosShaperCOS, + f3AccFpQosShaperStorageType, + f3AccFpQosShaperRowStatus + } + STATUS current + DESCRIPTION + "A collection of Access Flow Point QoS Shaper objects." + ::= { f3FpmGroups 2 } + +f3AccFpQosPolicerGroup OBJECT-GROUP + OBJECTS { + f3AccFpQosPolicerAdminState, + f3AccFpQosPolicerOperationalState, + f3AccFpQosPolicerSecondaryState, + f3AccFpQosPolicerCIRLo, + f3AccFpQosPolicerCIRHi, + f3AccFpQosPolicerEIRLo, + f3AccFpQosPolicerEIRHi, + f3AccFpQosPolicerCBS, + f3AccFpQosPolicerEBS, + f3AccFpQosPolicerAlgorithm, + f3AccFpQosPolicerColorMode, + f3AccFpQosPolicerCouplingFlag, + f3AccFpQosPolicerStorageType, + f3AccFpQosPolicerRowStatus + } + STATUS current + DESCRIPTION + "A collection of Access Flow Point QoS Policer objects." + ::= { f3FpmGroups 3 } + +f3MPFlowExtGroup OBJECT-GROUP + OBJECTS { + f3MPFlowExtMaxFwdEntries, + f3MPFlowRefConnectGuardFlowObject, + f3MPFlowSecureState + } + STATUS current + DESCRIPTION + "A collection of MP Flow objects." + ::= { f3FpmGroups 4 } + +f3AccFlowPointCpdV2Group OBJECT-GROUP + OBJECTS { + f3AccFlowPointCpdV2IslDispType, + f3AccFlowPointCpdV2PagpDispType, + f3AccFlowPointCpdV2UdldDispType, + f3AccFlowPointCpdV2CdpDispType, + f3AccFlowPointCpdV2VtpDispType, + f3AccFlowPointCpdV2DtpDispType, + f3AccFlowPointCpdV2PvstpPlusDispType, + f3AccFlowPointCpdV2UplinkFastDispType, + f3AccFlowPointCpdV2VlanBridgeDispType, + f3AccFlowPointCpdV2L2PTDispType, + f3AccFlowPointCpdV2BPDUDispType, + f3AccFlowPointCpdV2PauseDispType, + f3AccFlowPointCpdV2LACPDispType, + f3AccFlowPointCpdV2LACPMarkerDispType, + f3AccFlowPointCpdV2EfmOamDispType, + f3AccFlowPointCpdV2SSMDispType, + f3AccFlowPointCpdV2PortAuthenDispType, + f3AccFlowPointCpdV2LANBridgesDispType, + f3AccFlowPointCpdV2GMRPDispType, + f3AccFlowPointCpdV2GVRPDispType, + f3AccFlowPointCpdV2GARPDispType, + f3AccFlowPointCpdV2ActiveControlProtocols, + f3AccFlowPointCpdV2ELMIDispType, + f3AccFlowPointCpdV2Mac00DispType, + f3AccFlowPointCpdV2Mac01DispType, + f3AccFlowPointCpdV2Mac02DispType, + f3AccFlowPointCpdV2Mac03DispType, + f3AccFlowPointCpdV2Mac04DispType, + f3AccFlowPointCpdV2Mac05DispType, + f3AccFlowPointCpdV2Mac06DispType, + f3AccFlowPointCpdV2Mac07DispType, + f3AccFlowPointCpdV2Mac08DispType, + f3AccFlowPointCpdV2Mac09DispType, + f3AccFlowPointCpdV2Mac0ADispType, + f3AccFlowPointCpdV2Mac0BDispType, + f3AccFlowPointCpdV2Mac0CDispType, + f3AccFlowPointCpdV2Mac0DDispType, + f3AccFlowPointCpdV2Mac0EDispType, + f3AccFlowPointCpdV2Mac0FDispType, + f3AccFlowPointCpdV2NearestLLDPDispType, + f3AccFlowPointCpdV2NonTpmrLLDPDispType, + f3AccFlowPointCpdV2CustomerLLDPDispType + } + STATUS current + DESCRIPTION + "A collection of Access Flow Point CDPV2 objects." + ::= { f3FpmGroups 5 } + +f3AccFlowPointLearningConfigGroup OBJECT-GROUP + OBJECTS { + f3AccFlowPointLearningConfigLearningEnabled, + f3AccFlowPointLearningConfigMaxFwdEntries, + f3AccFlowPointLearningConfigProtectLearningCtrl, + f3AccFlowPointLearningConfigAction + } + STATUS current + DESCRIPTION + "A collection of Access Flowpoint Learning Config objects." + ::= { f3FpmGroups 6 } + +f3NetFlowPointGroup OBJECT-GROUP + OBJECTS { + f3NetFlowPointAlias, + f3NetFlowPointAdminState, + f3NetFlowPointOperationalState, + f3NetFlowPointSecondaryState, + f3NetFlowPointAssociatedFlowId, + f3NetFlowPointIngressMultiCOSEnabled, + f3NetFlowPointIngressCOS, + f3NetFlowPointEgressShapingType, + f3NetFlowPointIngressVlanMemberList, + f3NetFlowPointVlanMemberAction, + f3NetFlowPointVlanMemberActionVlan, + f3NetFlowPointIngressUntaggedFrameEnabled, + f3NetFlowPointCTagControl, + f3NetFlowPointCTagVlanId, + f3NetFlowPointCTagVlanPriority, + f3NetFlowPointSTagControl, + f3NetFlowPointSTagVlanId, + f3NetFlowPointSTagVlanPriority, + f3NetFlowPointEgressOuterTagPrioMapEnabled, + f3NetFlowPointEgressInnerTagPrioMapEnabled, + f3NetFlowPointSESFramesLossThresholdRatio, + f3NetFlowPointDefaultMemberEnabled, + f3NetFlowPointMcastRateLimitEnabled, + f3NetFlowPointMcastRateLimitSpeedLo, + f3NetFlowPointMcastRateLimitSpeedHi, + f3NetFlowPointBcastRateLimitEnabled, + f3NetFlowPointBcastRateLimitSpeedLo, + f3NetFlowPointBcastRateLimitSpeedHi, + f3NetFlowPointCombinedRateLimitEnabled, + f3NetFlowPointCombinedRateLimitSpeedLo, + f3NetFlowPointCombinedRateLimitSpeedHi, + f3NetFlowPointSplitHorizonGroupOID, + f3NetFlowPointLoopAvoidance, + f3NetFlowPointHierarchicalCOSEnabled, + f3NetFlowPointMaximumBWLo, + f3NetFlowPointMaximumBWHi, + f3NetFlowPointGuaranteedBWLo, + f3NetFlowPointGuaranteedBWHi, + f3NetFlowPointAutoBandwidthConfigEnabled, + f3NetFlowPointAutoCIRPercentage, + f3NetFlowPointFrameFwdEnabled, + f3NetFlowPointStorageType, + f3NetFlowPointRowStatus, + f3NetFlowPointUsePortPrioMapProfile, + f3NetFlowPointRefPrioMapProfile, + f3NetFlowpointRefConnectGuardFlowObject, + f3NetFlowpointSecureBlockingControl, + f3NetFlowpointSecureState + } + STATUS current + DESCRIPTION + "A collection of Network Flow Point objects." + ::= { f3FpmGroups 7 } + +f3NetFpQosShaperGroup OBJECT-GROUP + OBJECTS { + f3NetFpQosShaperIndex, + f3NetFpQosShaperAdminState, + f3NetFpQosShaperOperationalState, + f3NetFpQosShaperSecondaryState, + f3NetFpQosShaperCIRLo, + f3NetFpQosShaperCIRHi, + f3NetFpQosShaperCBS, + f3NetFpQosShaperEIRLo, + f3NetFpQosShaperEIRHi, + f3NetFpQosShaperEBS, + f3NetFpQosShaperBufferSize, + f3NetFpQosShaperCOS, + f3NetFpQosShaperStorageType, + f3NetFpQosShaperRowStatus + } + STATUS current + DESCRIPTION + "A collection of Network Flow Point QoS Shaper objects." + ::= { f3FpmGroups 8 } + +f3NetFpQosPolicerGroup OBJECT-GROUP + OBJECTS { + f3NetFpQosPolicerAdminState, + f3NetFpQosPolicerOperationalState, + f3NetFpQosPolicerSecondaryState, + f3NetFpQosPolicerCIRLo, + f3NetFpQosPolicerCIRHi, + f3NetFpQosPolicerEIRLo, + f3NetFpQosPolicerEIRHi, + f3NetFpQosPolicerCBS, + f3NetFpQosPolicerEBS, + f3NetFpQosPolicerAlgorithm, + f3NetFpQosPolicerColorMode, + f3NetFpQosPolicerCouplingFlag, + f3NetFpQosPolicerStorageType, + f3NetFpQosPolicerRowStatus + } + STATUS current + DESCRIPTION + "A collection of Network Flow Point QoS Policer objects." + ::= { f3FpmGroups 9 } + +f3NetFlowPointCpdV2Group OBJECT-GROUP + OBJECTS { + f3NetFlowPointCpdV2IslDispType, + f3NetFlowPointCpdV2PagpDispType, + f3NetFlowPointCpdV2UdldDispType, + f3NetFlowPointCpdV2CdpDispType, + f3NetFlowPointCpdV2VtpDispType, + f3NetFlowPointCpdV2DtpDispType, + f3NetFlowPointCpdV2PvstpPlusDispType, + f3NetFlowPointCpdV2UplinkFastDispType, + f3NetFlowPointCpdV2VlanBridgeDispType, + f3NetFlowPointCpdV2L2PTDispType, + f3NetFlowPointCpdV2BPDUDispType, + f3NetFlowPointCpdV2PauseDispType, + f3NetFlowPointCpdV2LACPDispType, + f3NetFlowPointCpdV2LACPMarkerDispType, + f3NetFlowPointCpdV2EfmOamDispType, + f3NetFlowPointCpdV2SSMDispType, + f3NetFlowPointCpdV2PortAuthenDispType, + f3NetFlowPointCpdV2LANBridgesDispType, + f3NetFlowPointCpdV2GMRPDispType, + f3NetFlowPointCpdV2GVRPDispType, + f3NetFlowPointCpdV2GARPDispType, + f3NetFlowPointCpdV2ActiveControlProtocols, + f3NetFlowPointCpdV2ELMIDispType, + f3NetFlowPointCpdV2Mac00DispType, + f3NetFlowPointCpdV2Mac01DispType, + f3NetFlowPointCpdV2Mac02DispType, + f3NetFlowPointCpdV2Mac03DispType, + f3NetFlowPointCpdV2Mac04DispType, + f3NetFlowPointCpdV2Mac05DispType, + f3NetFlowPointCpdV2Mac06DispType, + f3NetFlowPointCpdV2Mac07DispType, + f3NetFlowPointCpdV2Mac08DispType, + f3NetFlowPointCpdV2Mac09DispType, + f3NetFlowPointCpdV2Mac0ADispType, + f3NetFlowPointCpdV2Mac0BDispType, + f3NetFlowPointCpdV2Mac0CDispType, + f3NetFlowPointCpdV2Mac0DDispType, + f3NetFlowPointCpdV2Mac0EDispType, + f3NetFlowPointCpdV2Mac0FDispType, + f3NetFlowPointCpdV2NearestLLDPDispType, + f3NetFlowPointCpdV2NonTpmrLLDPDispType, + f3NetFlowPointCpdV2CustomerLLDPDispType + } + STATUS current + DESCRIPTION + "A collection of Network Flow Point CDPV2 objects." + ::= { f3FpmGroups 10 } + +f3NetFlowPointLearningConfigGroup OBJECT-GROUP + OBJECTS { + f3NetFlowPointLearningConfigLearningEnabled, + f3NetFlowPointLearningConfigMaxFwdEntries, + f3NetFlowPointLearningConfigProtectLearningCtrl, + f3NetFlowPointLearningConfigAction + } + STATUS current + DESCRIPTION + "A collection of Network Flowpoint Learning Config objects." + ::= { f3FpmGroups 11 } + +f3AccFlowPointPerfGroup OBJECT-GROUP + OBJECTS { + f3AccFlowPointStatsIndex, + f3AccFlowPointStatsIntervalType, + f3AccFlowPointStatsValid, + f3AccFlowPointStatsAction, + f3AccFlowPointStatsL2CPFD, + f3AccFlowPointStatsABRRx, + f3AccFlowPointStatsABRRLRx, + f3AccFlowPointStatsUAS, + f3AccFlowPointStatsSES, + f3AccFlowPointStatsFMG, + f3AccFlowPointStatsFMY, + f3AccFlowPointStatsFMRD, + f3AccFlowPointStatsFTD, + f3AccFlowPointStatsBytesIn, + f3AccFlowPointStatsBytesOut, + f3AccFlowPointStatsIBRMax, + f3AccFlowPointStatsIBRRlMax, + f3AccFlowPointStatsIBRMin, + f3AccFlowPointStatsIBRRlMin, + f3AccFlowPointStatsIBR, + f3AccFlowPointStatsIBRRl, + f3AccFlowPointStatsFBCD, + f3AccFlowPointStatsFMCD, + f3AccFlowPointStatsFdRxFb, + f3AccFlowPointStatsFdTxFb, + f3AccFlowPointStatsFdicd, + f3AccFlowPointStatsNumLearnTableFlushes, + f3AccFlowPointHistoryIndex, + f3AccFlowPointHistoryTime, + f3AccFlowPointHistoryValid, + f3AccFlowPointHistoryAction, + f3AccFlowPointHistoryL2CPFD, + f3AccFlowPointHistoryABRRx, + f3AccFlowPointHistoryABRRLRx, + f3AccFlowPointHistoryUAS, + f3AccFlowPointHistorySES, + f3AccFlowPointHistoryFMG, + f3AccFlowPointHistoryFMY, + f3AccFlowPointHistoryFMRD, + f3AccFlowPointHistoryFTD, + f3AccFlowPointHistoryBytesIn, + f3AccFlowPointHistoryBytesOut, + f3AccFlowPointHistoryIBRMax, + f3AccFlowPointHistoryIBRRlMax, + f3AccFlowPointHistoryIBRMin, + f3AccFlowPointHistoryIBRRlMin, + f3AccFlowPointHistoryIBR, + f3AccFlowPointHistoryIBRRl, + f3AccFlowPointHistoryFBCD, + f3AccFlowPointHistoryFMCD, + f3AccFlowPointHistoryFdRxFb, + f3AccFlowPointHistoryFdTxFb, + f3AccFlowPointHistoryFdicd, + f3AccFlowPointHistoryNumLearnTableFlushes, + f3AccFlowPointThresholdIndex, + f3AccFlowPointThresholdInterval, + f3AccFlowPointThresholdVariable, + f3AccFlowPointThresholdValueLo, + f3AccFlowPointThresholdValueHi, + f3AccFlowPointThresholdMonValue + } + STATUS current + DESCRIPTION + "A collection of Access Flowpoint Performance objects." + ::= { f3FpmGroups 12 } + +f3NetFlowPointPerfGroup OBJECT-GROUP + OBJECTS { + f3NetFlowPointStatsIndex, + f3NetFlowPointStatsIntervalType, + f3NetFlowPointStatsValid, + f3NetFlowPointStatsAction, + f3NetFlowPointStatsL2CPFD, + f3NetFlowPointStatsABRRx, + f3NetFlowPointStatsABRRLRx, + f3NetFlowPointStatsUAS, + f3NetFlowPointStatsSES, + f3NetFlowPointStatsFMG, + f3NetFlowPointStatsFMY, + f3NetFlowPointStatsFMRD, + f3NetFlowPointStatsFTD, + f3NetFlowPointStatsBytesIn, + f3NetFlowPointStatsBytesOut, + f3NetFlowPointStatsIBRMax, + f3NetFlowPointStatsIBRRlMax, + f3NetFlowPointStatsIBRMin, + f3NetFlowPointStatsIBRRlMin, + f3NetFlowPointStatsIBR, + f3NetFlowPointStatsIBRRl, + f3NetFlowPointStatsFBCD, + f3NetFlowPointStatsFMCD, + f3NetFlowPointStatsFdRxFb, + f3NetFlowPointStatsFdTxFb, + f3NetFlowPointStatsFdicd, + f3NetFlowPointStatsNumLearnTableFlushes, + f3NetFlowPointHistoryIndex, + f3NetFlowPointHistoryTime, + f3NetFlowPointHistoryValid, + f3NetFlowPointHistoryAction, + f3NetFlowPointHistoryL2CPFD, + f3NetFlowPointHistoryABRRx, + f3NetFlowPointHistoryABRRLRx, + f3NetFlowPointHistoryUAS, + f3NetFlowPointHistorySES, + f3NetFlowPointHistoryFMG, + f3NetFlowPointHistoryFMY, + f3NetFlowPointHistoryFMRD, + f3NetFlowPointHistoryFTD, + f3NetFlowPointHistoryBytesIn, + f3NetFlowPointHistoryBytesOut, + f3NetFlowPointHistoryIBRMax, + f3NetFlowPointHistoryIBRRlMax, + f3NetFlowPointHistoryIBRMin, + f3NetFlowPointHistoryIBRRlMin, + f3NetFlowPointHistoryIBR, + f3NetFlowPointHistoryIBRRl, + f3NetFlowPointHistoryFBCD, + f3NetFlowPointHistoryFMCD, + f3NetFlowPointHistoryFdRxFb, + f3NetFlowPointHistoryFdTxFb, + f3NetFlowPointHistoryFdicd, + f3NetFlowPointHistoryNumLearnTableFlushes, + f3NetFlowPointThresholdIndex, + f3NetFlowPointThresholdInterval, + f3NetFlowPointThresholdVariable, + f3NetFlowPointThresholdValueLo, + f3NetFlowPointThresholdValueHi, + f3NetFlowPointThresholdMonValue + } + STATUS current + DESCRIPTION + "A collection of Network Flowpoint Performance objects." + ::= { f3FpmGroups 13 } + +f3MPFlowPerfGroup OBJECT-GROUP + OBJECTS { + f3MPFlowStatsIndex, + f3MPFlowStatsIntervalType, + f3MPFlowStatsValid, + f3MPFlowStatsAction, + f3MPFlowStatsFDStaticBlock, + f3MPFlowStatsFDHairPin, + f3MPFlowStatsMacTableDiscards, + f3MPFlowStatsFDProtLearn, + f3MPFlowHistoryIndex, + f3MPFlowHistoryTime, + f3MPFlowHistoryValid, + f3MPFlowHistoryAction, + f3MPFlowHistoryFDStaticBlock, + f3MPFlowHistoryFDHairPin, + f3MPFlowHistoryMacTableDiscards, + f3MPFlowHistoryFDProtLearn, + f3MPFlowThresholdIndex, + f3MPFlowThresholdInterval, + f3MPFlowThresholdVariable, + f3MPFlowThresholdValueLo, + f3MPFlowThresholdValueHi, + f3MPFlowThresholdMonValue + } + STATUS current + DESCRIPTION + "A collection of MP Flow Performance objects." + ::= { f3FpmGroups 14 } + +f3AccFpQosShaperPerfGroup OBJECT-GROUP + OBJECTS { + f3AccFpQosShaperStatsIndex, + f3AccFpQosShaperStatsIntervalType, + f3AccFpQosShaperStatsValid, + f3AccFpQosShaperStatsAction, + f3AccFpQosShaperStatsBT, + f3AccFpQosShaperStatsBTD, + f3AccFpQosShaperStatsFD, + f3AccFpQosShaperStatsFTD, + f3AccFpQosShaperStatsABRRL, + f3AccFpQosShaperStatsBREDD, + f3AccFpQosShaperStatsFREDD, + f3AccFpQosShaperHistoryIndex, + f3AccFpQosShaperHistoryTime, + f3AccFpQosShaperHistoryValid, + f3AccFpQosShaperHistoryAction, + f3AccFpQosShaperHistoryBT, + f3AccFpQosShaperHistoryBTD, + f3AccFpQosShaperHistoryFD, + f3AccFpQosShaperHistoryFTD, + f3AccFpQosShaperHistoryABRRL, + f3AccFpQosShaperHistoryBREDD, + f3AccFpQosShaperHistoryFREDD, + f3AccFpQosShaperThresholdIndex, + f3AccFpQosShaperThresholdInterval, + f3AccFpQosShaperThresholdVariable, + f3AccFpQosShaperThresholdValueLo, + f3AccFpQosShaperThresholdValueHi, + f3AccFpQosShaperThresholdMonValue + } + STATUS current + DESCRIPTION + "A collection of Acc FlowPoint QoS Shaper Performance objects." + ::= { f3FpmGroups 15 } + +f3NetFpQosShaperPerfGroup OBJECT-GROUP + OBJECTS { + f3NetFpQosShaperStatsIndex, + f3NetFpQosShaperStatsIntervalType, + f3NetFpQosShaperStatsValid, + f3NetFpQosShaperStatsAction, + f3NetFpQosShaperStatsBT, + f3NetFpQosShaperStatsBTD, + f3NetFpQosShaperStatsFD, + f3NetFpQosShaperStatsFTD, + f3NetFpQosShaperStatsABRRL, + f3NetFpQosShaperStatsBREDD, + f3NetFpQosShaperStatsFREDD, + f3NetFpQosShaperHistoryIndex, + f3NetFpQosShaperHistoryTime, + f3NetFpQosShaperHistoryValid, + f3NetFpQosShaperHistoryAction, + f3NetFpQosShaperHistoryBT, + f3NetFpQosShaperHistoryBTD, + f3NetFpQosShaperHistoryFD, + f3NetFpQosShaperHistoryFTD, + f3NetFpQosShaperHistoryABRRL, + f3NetFpQosShaperHistoryBREDD, + f3NetFpQosShaperHistoryFREDD, + f3NetFpQosShaperThresholdIndex, + f3NetFpQosShaperThresholdInterval, + f3NetFpQosShaperThresholdVariable, + f3NetFpQosShaperThresholdValueLo, + f3NetFpQosShaperThresholdValueHi, + f3NetFpQosShaperThresholdMonValue + } + STATUS current + DESCRIPTION + "A collection of Net FlowPoint QoS Shaper Performance objects." + ::= { f3FpmGroups 16 } + +f3AccFpQosPolicerPerfGroup OBJECT-GROUP + OBJECTS { + f3AccFpQosPolicerStatsIndex, + f3AccFpQosPolicerStatsIntervalType, + f3AccFpQosPolicerStatsValid, + f3AccFpQosPolicerStatsAction, + f3AccFpQosPolicerStatsFMG, + f3AccFpQosPolicerStatsFMY, + f3AccFpQosPolicerStatsFMRD, + f3AccFpQosPolicerStatsBytesIn, + f3AccFpQosPolicerStatsBytesOut, + f3AccFpQosPolicerStatsABR, + f3AccFpQosPolicerHistoryIndex, + f3AccFpQosPolicerHistoryTime, + f3AccFpQosPolicerHistoryValid, + f3AccFpQosPolicerHistoryAction, + f3AccFpQosPolicerHistoryFMG, + f3AccFpQosPolicerHistoryFMY, + f3AccFpQosPolicerHistoryFMRD, + f3AccFpQosPolicerHistoryBytesIn, + f3AccFpQosPolicerHistoryBytesOut, + f3AccFpQosPolicerHistoryABR, + f3AccFpQosPolicerThresholdIndex, + f3AccFpQosPolicerThresholdInterval, + f3AccFpQosPolicerThresholdVariable, + f3AccFpQosPolicerThresholdValueLo, + f3AccFpQosPolicerThresholdValueHi, + f3AccFpQosPolicerThresholdMonValue + } + STATUS current + DESCRIPTION + "A collection of Acc FlowPoint QoS Policer Performance objects." + ::= { f3FpmGroups 17 } + +f3NetFpQosPolicerPerfGroup OBJECT-GROUP + OBJECTS { + f3NetFpQosPolicerStatsIndex, + f3NetFpQosPolicerStatsIntervalType, + f3NetFpQosPolicerStatsValid, + f3NetFpQosPolicerStatsAction, + f3NetFpQosPolicerStatsFMG, + f3NetFpQosPolicerStatsFMY, + f3NetFpQosPolicerStatsFMRD, + f3NetFpQosPolicerStatsBytesIn, + f3NetFpQosPolicerStatsBytesOut, + f3NetFpQosPolicerStatsABR, + f3NetFpQosPolicerHistoryIndex, + f3NetFpQosPolicerHistoryTime, + f3NetFpQosPolicerHistoryValid, + f3NetFpQosPolicerHistoryAction, + f3NetFpQosPolicerHistoryFMG, + f3NetFpQosPolicerHistoryFMY, + f3NetFpQosPolicerHistoryFMRD, + f3NetFpQosPolicerHistoryBytesIn, + f3NetFpQosPolicerHistoryBytesOut, + f3NetFpQosPolicerHistoryABR, + f3NetFpQosPolicerThresholdIndex, + f3NetFpQosPolicerThresholdInterval, + f3NetFpQosPolicerThresholdVariable, + f3NetFpQosPolicerThresholdValueLo, + f3NetFpQosPolicerThresholdValueHi, + f3NetFpQosPolicerThresholdMonValue + } + STATUS current + DESCRIPTION + "A collection of Net FlowPoint QoS Policer Performance objects." + ::= { f3FpmGroups 18 } + +f3FpmPerfNotifGroup NOTIFICATION-GROUP + NOTIFICATIONS { + f3AccFlowPointThresholdCrossingAlert, + f3NetFlowPointThresholdCrossingAlert, + f3MPFlowThresholdCrossingAlert, + f3AccFpQosShaperThresholdCrossingAlert, + f3NetFpQosShaperThresholdCrossingAlert, + f3AccFpQosPolicerThresholdCrossingAlert, + f3NetFpQosPolicerThresholdCrossingAlert + } + STATUS current + DESCRIPTION + "A collection of notifications related to FSP150CC + Threshold Crossing Alerts." + ::= { f3FpmGroups 19 } + +END |