diff options
| author | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
|---|---|---|
| committer | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
| commit | 98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch) | |
| tree | 9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/arris/BCS-IDENT-MIB | |
| download | mibs-main.tar.gz mibs-main.zip | |
Diffstat (limited to 'MIBS/arris/BCS-IDENT-MIB')
| -rw-r--r-- | MIBS/arris/BCS-IDENT-MIB | 887 |
1 files changed, 887 insertions, 0 deletions
diff --git a/MIBS/arris/BCS-IDENT-MIB b/MIBS/arris/BCS-IDENT-MIB new file mode 100644 index 0000000..666da1f --- /dev/null +++ b/MIBS/arris/BCS-IDENT-MIB @@ -0,0 +1,887 @@ +BCS-IDENT-MIB DEFINITIONS ::= BEGIN
+
+IMPORTS
+
+ DisplayString FROM SNMPv2-TC
+ OBJECT-TYPE FROM SNMPv2-SMI
+ MODULE-IDENTITY FROM SNMPv2-SMI;
+
+gi MODULE-IDENTITY
+ LAST-UPDATED "201008250000Z"
+
+ ORGANIZATION "Motorola Broadband Home Solutions"
+ CONTACT-INFO "Motorola Technical Response Center
+ Inside USA 1-888-944-HELP (1-888-944-4357)
+ Outside USA 1-215-323-0044
+ TRC Hours:
+ Monday through Friday 8am - 7pm Eastern Standard Time
+ Saturdays 10am - 5pm Eastern Standard Time"
+
+ DESCRIPTION "The SMIv2 MIB module for the MOTOROLA BCS common ident objects.
+ The MIB Tree for this is shown below."
+
+ ::= {iso org(3) dod(6) internet(1) private(4) enterprises(1) 1166}
+
+
+ giproducts OBJECT IDENTIFIER ::= { gi 1 }
+ acc4000d OBJECT IDENTIFIER ::= { giproducts 1 }
+ anicd OBJECT IDENTIFIER ::= { giproducts 2 }
+ item1000 OBJECT IDENTIFIER ::= { giproducts 4 }
+ irt1000 OBJECT IDENTIFIER ::= { giproducts 5 }
+ nc1500 OBJECT IDENTIFIER ::= { giproducts 6 }
+-- OM-2000 shares same OID as OM-1000
+ om1000 OBJECT IDENTIFIER ::= { giproducts 7 }
+ im1000 OBJECT IDENTIFIER ::= { giproducts 8 }
+ mps OBJECT IDENTIFIER ::= { giproducts 9 }
+
+ rpd1000 OBJECT IDENTIFIER ::= { giproducts 10 }
+
+-- Access Control Processors; TSODAs and other ACPs in various products.
+ acpStatus OBJECT IDENTIFIER ::= { giproducts 11 }
+-- Heartbeat MIB used in the Satellite environment
+ heartbeat OBJECT IDENTIFIER ::= { giproducts 12 }
+-- Entitlement Key Common MIB - used by SDM/SEM
+ entitlementKey OBJECT IDENTIFIER ::= { giproducts 13 }
+
+ arpd OBJECT IDENTIFIER ::= { giproducts 14 }
+ svom OBJECT IDENTIFIER ::= { giproducts 15 }
+ svm OBJECT IDENTIFIER ::= { giproducts 16 }
+ erm OBJECT IDENTIFIER ::= { giproducts 17 }
+
+-- GI SURBboard BNH
+ surfBbnh OBJECT IDENTIFIER ::= { giproducts 18 }
+
+-- GI SURFboard cable modem
+ sb2100 OBJECT IDENTIFIER ::= { giproducts 19 }
+ sb2100D OBJECT IDENTIFIER ::= { giproducts 20 }
+ sb2000 OBJECT IDENTIFIER ::= { giproducts 21 }
+
+-- CHS digital video headend equipment
+--
+ saDANIS OBJECT IDENTIFIER ::= { giproducts 30 }
+ apex OBJECT IDENTIFIER ::= { giproducts 31 }
+ rem OBJECT IDENTIFIER ::= { giproducts 32 }
+ mpe OBJECT IDENTIFIER ::= { giproducts 33 }
+ spe OBJECT IDENTIFIER ::= { giproducts 34 }
+ ne2000 OBJECT IDENTIFIER ::= { giproducts 35 }
+ apex1500 OBJECT IDENTIFIER ::= { giproducts 36 }
+ agb OBJECT IDENTIFIER ::= { giproducts 37 }
+ ne2500 OBJECT IDENTIFIER ::= { giproducts 38 }
+--
+ hdd2000 OBJECT IDENTIFIER ::= { giproducts 40 }
+--
+ merlin OBJECT IDENTIFIER ::= { giproducts 50 }
+--
+ rsr OBJECT IDENTIFIER ::= { giproducts 60 }
+ gsrm OBJECT IDENTIFIER ::= { giproducts 61 }
+ gom OBJECT IDENTIFIER ::= { giproducts 62 }
+ b3 OBJECT IDENTIFIER ::= { giproducts 63 }
+ adm OBJECT IDENTIFIER ::= { giproducts 64 }
+
+-- San Diego Headend devices
+
+ sem OBJECT IDENTIFIER ::= { giproducts 70 }
+ ecmg OBJECT IDENTIFIER ::= { giproducts 71 }
+ bsiAdapter OBJECT IDENTIFIER ::= { giproducts 72 }
+ oles OBJECT IDENTIFIER ::= { giproducts 73 }
+ ne OBJECT IDENTIFIER ::= { giproducts 74 }
+ tmxCommTrap OBJECT IDENTIFIER ::= { giproducts 75 }
+ drmenginekskdc OBJECT IDENTIFIER ::= { giproducts 76 }
+ drmenginerte OBJECT IDENTIFIER ::= { giproducts 77 }
+ drmengineecmg OBJECT IDENTIFIER ::= { giproducts 78 }
+ drmengineskgpkg OBJECT IDENTIFIER ::= { giproducts 79 }
+ tmx OBJECT IDENTIFIER ::= { giproducts 80 }
+ prs OBJECT IDENTIFIER ::= { giproducts 81 }
+ se2000 OBJECT IDENTIFIER ::= { giproducts 82 }
+ dem OBJECT IDENTIFIER ::= { giproducts 83 }
+ ncs OBJECT IDENTIFIER ::= { giproducts 84 }
+ ucs OBJECT IDENTIFIER ::= { giproducts 85 }
+ lmm OBJECT IDENTIFIER ::= { giproducts 86 }
+ se4000 OBJECT IDENTIFIER ::= { giproducts 87 }
+ rc OBJECT IDENTIFIER ::= { giproducts 88 }
+
+--
+-- Element Management System Range
+--
+ netSentry OBJECT IDENTIFIER ::= { giproducts 99 }
+ sdm OBJECT IDENTIFIER ::= { giproducts 100 }
+ hfcEms OBJECT IDENTIFIER ::= { giproducts 101 }
+ bnc OBJECT IDENTIFIER ::= { giproducts 102 }
+ drmenginecm OBJECT IDENTIFIER ::= { giproducts 103 }
+ stdc OBJECT IDENTIFIER ::= { giproducts 104 }
+ tview OBJECT IDENTIFIER ::= { giproducts 105 }
+--
+-- OIDS 106 thru 110 reserved for other EMS
+--
+--
+--
+-- OIDS 150 thru 225 reserved for TNS/NIS
+--
+ ponOa OBJECT IDENTIFIER ::= { giproducts 150 }
+ mwtea200 OBJECT IDENTIFIER ::= { giproducts 151 }
+
+ bti OBJECT IDENTIFIER ::= { giproducts 200 }
+ rfModMIB OBJECT IDENTIFIER ::= { giproducts 201 }
+ btiIntMIB OBJECT IDENTIFIER ::= { giproducts 202 }
+ sg4000 OBJECT IDENTIFIER ::= { giproducts 203 }
+
+ ponEm870 OBJECT IDENTIFIER ::= { giproducts 210 }
+--
+-- OIDS 250 thru 290 reserved for TAS
+--
+ rpa OBJECT IDENTIFIER ::= { giproducts 250 }
+ rpc OBJECT IDENTIFIER ::= { giproducts 251 }
+--
+-- OIDS 300 thru 310 reserved for ASTBs
+--
+ dct5000 OBJECT IDENTIFIER ::= { giproducts 300 }
+ dct5100 OBJECT IDENTIFIER ::= { giproducts 301 }
+ dct5200 OBJECT IDENTIFIER ::= { giproducts 302 }
+--
+-- OIDS 314 thru 320 reserved for other CPEs
+--
+ edfaMIB OBJECT IDENTIFIER ::= { giproducts 311 }
+ corvusMIB OBJECT IDENTIFIER ::= { giproducts 312 }
+ oa600 OBJECT IDENTIFIER ::= { giproducts 313 }
+--
+-- Range 321-330 reserved for DSRs
+--
+ dsr350f OBJECT IDENTIFIER ::= { giproducts 321 }
+
+ radd6000 OBJECT IDENTIFIER ::= { giproducts 400 }
+ cs1000 OBJECT IDENTIFIER ::= { giproducts 401 }
+ kls OBJECT IDENTIFIER ::= { giproducts 402 }
+ dac6000 OBJECT IDENTIFIER ::= { giproducts 403 }
+ sdi OBJECT IDENTIFIER ::= { giproducts 404 }
+ cpms OBJECT IDENTIFIER ::= { giproducts 405 }
+ ap OBJECT IDENTIFIER ::= { giproducts 406 }
+ ps OBJECT IDENTIFIER ::= { giproducts 407 }
+--
+-- Range 350-359 reserved for Cable Cards
+--
+ cableCard OBJECT IDENTIFIER ::= { giproducts 350 }
+--
+-- The following branch identifies the BCS/IPNS Devices MIB.
+--
+ motoIPNSprodID OBJECT IDENTIFIER ::= { giproducts 450 }
+--
+-- Range 500-510 reserved for Simulcrypt
+--
+--
+-- Range 600-650 reserved for IRDs
+--
+ ird4500x OBJECT IDENTIFIER ::= { giproducts 610 }
+ ird4520x OBJECT IDENTIFIER ::= { giproducts 620 }
+
+
+ giproxies OBJECT IDENTIFIER ::= { gi 3 }
+
+ gicommon OBJECT IDENTIFIER ::= { gi 4 }
+ identity OBJECT IDENTIFIER ::= { gicommon 1 }
+ state OBJECT IDENTIFIER ::= { gicommon 2 }
+ traps OBJECT IDENTIFIER ::= { gicommon 3 }
+ logs OBJECT IDENTIFIER ::= { gicommon 4 }
+--
+-- nlsbbn OBJECT IDENTIFIER ::= { gi 5 }
+-- added to create new path for gx2 hfc common and device mibs
+ motproxies OBJECT IDENTIFIER ::= { gi 6 }
+
+--
+-- The following is the SMIv2 COMMON MIB branch
+--
+ bcs OBJECT IDENTIFIER ::= { gi 7 }
+ bcsIdent OBJECT IDENTIFIER ::= { bcs 1 }
+-- bcsState OBJECT IDENTIFIER ::= { bcs 2 }
+-- bcsTraps OBJECT IDENTIFIER ::= { bcs 3 }
+ bcsLogs OBJECT IDENTIFIER ::= { bcs 4 }
+
+-- dms OBJECT IDENTIFIER ::= { bcs 5 }
+--
+-- New OID for SMIv2 of ACP MIB
+--
+-- bcs_acp OBJECT IDENTIFIER ::= { bcs 6 }
+--
+-- bcs OID 7 - 10 reserved for Simulcrypt
+--
+ bcsSimulcryptScs OBJECT IDENTIFIER ::= { bcs 7 }
+ bcsSimulcryptMux OBJECT IDENTIFIER ::= { bcs 8 }
+ bcsSimulcrypt OBJECT IDENTIFIER ::= { bcs 9 }
+
+-- bcs OID 11 - 20 reserved for common BCS infrastructure MIBs
+--
+ bcsDatabase OBJECT IDENTIFIER ::= { bcs 11 }
+ bcsRedundancy OBJECT IDENTIFIER ::= { bcs 12 }
+
+ bcsMsgGeneration OBJECT IDENTIFIER ::= { bcs 21 }
+--
+-- Reserved for TNS
+ mea OBJECT IDENTIFIER ::= { gi 8 }
+--
+-- Reserved for common Addressable Control MIBs
+ addressablecontrol OBJECT IDENTIFIER ::= { gi 9 }
+ acCommon OBJECT IDENTIFIER ::= { addressablecontrol 1 }
+ acSecurity OBJECT IDENTIFIER ::= { addressablecontrol 2 }
+ acServices OBJECT IDENTIFIER ::= { addressablecontrol 3 }
+ acBsi OBJECT IDENTIFIER ::= { addressablecontrol 4 }
+ acOperations OBJECT IDENTIFIER ::= { addressablecontrol 5 }
+ acTopology OBJECT IDENTIFIER ::= { addressablecontrol 6 }
+
+--
+-- Reserved for common CHS internal MIBs
+ chsInternal OBJECT IDENTIFIER ::= { gi 10 }
+ emLogin OBJECT IDENTIFIER ::= { chsInternal 1 }
+ radiusClient OBJECT IDENTIFIER ::= { chsInternal 2 }
+
+-- Need to explicitly define EntryStatus since most do not recognize
+-- the version 1 format.
+EntryStatus ::= INTEGER
+ { valid(1),
+ createRequest(2),
+ underCreation(3),
+ invalid(4)
+ }
+
+ -- groups in the GI-IDENT MIB
+
+-- MIB Tree
+--
+-- The following diagram defining the objects in this MIB is for
+-- reference purposes only.
+--
+-- bcs
+-- |
+-- +..bcsIdent
+-- | |
+-- | +..identSerialNumber
+-- | |
+-- | +..identChassisNumber
+-- | |
+-- | +..identIfIndex
+-- | |
+-- | +..identHardwareVersion
+-- | |
+-- | +..identHardwareFeatures
+-- | |
+-- | +..identInventoryCode
+-- | |
+-- | +..identSoftwareVersion
+-- | |
+-- | +..identLocationArea
+-- | |
+-- | +..identLocationRack
+-- | |
+-- | +..identLocationShelf
+-- | |
+-- | +..identMIBVersion
+-- | |
+-- | +..identAgentVersion
+-- | |
+-- | +..identCommand
+-- | |
+-- | +..identIfExtensionTable
+-- | | |
+-- | | +..identIfExtensionEntry
+-- | | |
+-- | | +..identIfExtensionIndex
+-- | | |
+-- | | +..identIfSerialNumber
+-- | | |
+-- | | +..identIfHardwareVersion
+-- | | |
+-- | | +..identIfHardwareFeatures
+-- | | |
+-- | | +..identIfInventoryCode
+-- | | |
+-- | | +..identIfFirmwareVersion1
+-- | | |
+-- | | +..identIfFirmwareVersion2
+-- | | |
+-- | | +..identIfFirmwareVersion3
+-- | | |
+-- | | +..identIfFirmwareVersion4
+-- | | |
+-- | | +..identIfSlotId
+-- | | |
+-- | | +..identIfCommand
+-- | | |
+-- | | +..identIfAdministrativeState
+-- | | |
+-- | | +..identIfOperationalState
+-- | | |
+-- | | +..identIfAlarmStatus
+-- | | |
+-- | | +..identIfAvailabilityStatus
+-- | | |
+-- | | +..identIfSpecific
+-- | | |
+-- | | +..identIfEntryStatus
+-- | |
+-- | +..identUnitModel
+
+
+
+-- The Identification Group.
+
+-- This group of objects contains the identification of the software
+-- and hardware for a specific unit.
+
+ identSerialNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This contains the serial number of the unit. There is no
+ specification of the internal format of the serial number.
+ The serial number is entered into either permanent or non-
+ volatile memory of the unit at the time of manufacture.
+ Note - the unit itself supplies the serial number."
+ REFERENCE " -- "
+ ::= { bcsIdent 1 }
+
+ identChassisNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This contains the chassis number of the unit. This is
+ applicable only to a limited number of products,
+ currently, only the ITEM-1000. For products for which
+ this is not applicable, this will be a null object.
+ There is no specification of the internal format of
+ the chassis number. The means by which any product
+ determines its chassis number is to be determined by
+ each individual product."
+ REFERENCE " -- "
+ ::= { bcsIdent 2 }
+
+
+ identIfIndex OBJECT-TYPE
+ SYNTAX INTEGER (1..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This contains the IfIndex of the OAM&P port."
+ REFERENCE " -- "
+ DEFVAL { 2147483647 }
+ ::= { bcsIdent 3 }
+
+
+ identHardwareVersion OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This contains a display string that defines the hardware
+ version of this particular unit. There is no specification
+ of the internal format of the hardware version. The
+ hardware version is entered into the either permanent or
+ non-volatile memory of the unit at the time of
+ manufacture."
+ REFERENCE " -- "
+ ::= { bcsIdent 4 }
+
+
+ identHardwareFeatures OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This contains a display string that defines the features
+ of this particular unit. There is no specification of the
+ internal format of the hardware features. The hardware
+ features is entered into the either permanent or
+ non-volatile memory of the unit at the time of
+ manufacture."
+ REFERENCE " -- "
+ ::= { bcsIdent 5 }
+
+
+ identInventoryCode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This contains a display string that defines the inventory
+ code for this unit.
+ Once an inventory code has been set, it should be kept in
+ non-volatile memory. The unit should only allow this object
+ to be set when it is in the 'configuration' mode. There is
+ no specification of the internal format of the inventory
+ Code."
+ REFERENCE " -- "
+ ::= { bcsIdent 6 }
+
+
+ identSoftwareVersion OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This contains a display string that defines the current
+ version of the software for this unit. The format of the
+ software version is a fully qualified directory name. This
+ value is received by a unit as within a BOOTP response from
+ the BOOTP server. It is available to the network manager
+ for applications that track the installed software. Once
+ the software version has been set, it should be kept in
+ non-volatile memory."
+ REFERENCE " -- "
+ ::= { bcsIdent 7 }
+
+
+ identLocationArea OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This is different from the MIB II sysLocation variable as it
+ contains only the location area and does not describe the
+ precise location.
+ This contains a display string that defines the area in
+ which the unit is installed. Location is defined by a set
+ of three objects: 'Area', 'Rack', and 'Shelf'. These
+ location objects cannot be determined by the unit itself,
+ but can only be determined by the network manager. It is
+ available to the unit for display on a front panel. Display
+ of the location on the front panel is useful in validating
+ the configuration established by the network manager. The
+ unit should only allow this object to be set when it is in
+ the 'configuration' mode. Once the Location Area has been
+ set, it should be kept in non-volatile memory."
+ REFERENCE " -- "
+ ::= { bcsIdent 8 }
+
+
+ identLocationRack OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This contains a display string that defines the rack in
+ which the unit is installed. Location is defined by a set
+ of three objects: 'Area', 'Rack', and 'Shelf'. These
+ location objects cannot be determined by the unit itself,
+ but can only be determined by the network manager. It is
+ available to the unit for display on a front panel. Display
+ of the location on the front panel is useful in validating
+ the configuration established by the network manager. The
+ unit should only allow this object to be set when it is in
+ the 'configuration' mode. Once the Location Area has been
+ set, it should be kept in non-volatile memory."
+ REFERENCE " -- "
+ ::= { bcsIdent 9 }
+
+
+ identLocationShelf OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This contains a display string that defines the shelf in
+ which the unit is installed. Location is defined by a set
+ of three objects: 'Area', 'Rack', and 'Shelf'. These
+ location objects cannot be determined by the unit itself,
+ but can only be determined by the network manager. It is
+ available to the unit for display on a front panel. Display
+ of the location on the front panel is useful in validating
+ the configuration established by the network manager. The
+ unit should only allow this object to be set when it is in
+ the 'configuration' mode. Once the Location Area has been
+ set, it should be kept in non-volatile memory."
+ REFERENCE " -- "
+ ::= { bcsIdent 10 }
+
+
+
+ identMIBVersion OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ " The version number of this MIB."
+ REFERENCE " -- "
+ ::= { bcsIdent 11 }
+
+
+ identAgentVersion OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The version number of the Agent."
+ REFERENCE " -- "
+ ::= { bcsIdent 12 }
+
+
+ identCommand OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ restart(1),
+ currentlyRestarting(2),
+ unspecified(3),
+ purgeAndRestart(4),
+ currentlyPurgingAndRestarting(5),
+ purgeNvramAndRestart(6),
+ currentlyPurgingNvramAndRestarting(7)
+ }
+
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This is the command to be executed by the resource
+ managed by the agent.
+ The value unspecified is always returned on SNMP
+ Get/GetNext while the resource is running. If the
+ restart(1) command is given, currentlyRestarting(2)
+ is returned while the resource is preparing to
+ restart (reboot)."
+ REFERENCE " -- "
+ ::= { bcsIdent 13 }
+
+
+ identIfExtensionTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IdentIfExtensionEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table contains extensions to the MIB II ifTable which contains
+ the definitions of all interfaces. An ifTable entry may be a board
+ or just a port on a board. Any ifTable entry can have an extension
+ in the identIfExtensionTable. The corrsponding entry in that table
+ will have the identIfIndex = ifIndex. Within the ifTable the presence
+ of such an entry is indicated by setting the variable ifSpecific
+ to the OBJECT IDENTIFIER value of identIfExtensionTable. Otherwise
+ iFSpecific is set to {0 0}.
+ The ifType - other - is used for all board types not envisoned by
+ MIB II."
+ REFERENCE " -- "
+ ::= { bcsIdent 14 }
+
+
+ identIfExtensionEntry OBJECT-TYPE
+ SYNTAX IdentIfExtensionEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry (conceptual row) in the Board Table."
+ REFERENCE " -- "
+ INDEX { identIfExtensionIndex }
+ ::= { identIfExtensionTable 1 }
+
+
+
+ IdentIfExtensionEntry ::= SEQUENCE
+ {
+ identIfExtensionIndex INTEGER,
+ identIfSerialNumber DisplayString,
+ identIfHardwareVersion DisplayString,
+ identIfHardwareFeatures DisplayString,
+ identIfInventoryCode DisplayString,
+ identIfFirmwareVersion1 DisplayString,
+ identIfFirmwareVersion2 DisplayString,
+ identIfFirmwareVersion3 DisplayString,
+ identIfFirmwareVersion4 DisplayString,
+ identIfSlotId INTEGER,
+ identIfCommand INTEGER,
+ identIfAdministrativeState INTEGER,
+ identIfOperationalState INTEGER,
+ identIfAlarmStatus INTEGER,
+ identIfAvailabilityStatus INTEGER,
+ identIfSpecific OBJECT IDENTIFIER,
+ identIfEntryStatus EntryStatus
+ }
+
+
+ identIfExtensionIndex OBJECT-TYPE
+ SYNTAX INTEGER (1..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Same value as ifIndex of MIB II for the same board."
+ REFERENCE " -- "
+ DEFVAL { 2147483647 }
+ ::= { identIfExtensionEntry 1 }
+
+
+ identIfSerialNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This contains the serial number of the board. There is no
+ specification of the internal format of the serial number.
+ The serial number is entered into either permanent or
+ non-volatile memory of the unit at the time of manufacture.
+ Note - the unit itself supplies the serial number."
+ REFERENCE " -- "
+ ::= { identIfExtensionEntry 2 }
+
+
+
+ identIfHardwareVersion OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This contains a display string that defines the version
+ of this particular board. There is no specification of the
+ internal format of the hardware version. The hardware
+ version is entered into the either permanent or
+ non-volatile memory of the unit at the time of
+ manufacture."
+ REFERENCE " -- "
+ ::= { identIfExtensionEntry 3 }
+
+
+ identIfHardwareFeatures OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This contains a display string that defines the features of
+ this particular board. There is no specification of the
+ internal format of the hardware features. The hardware
+ features is entered into the either permanent or
+ non-volatile memory of the unit at the time of manufacture."
+ REFERENCE " -- "
+ ::= { identIfExtensionEntry 4 }
+
+
+ identIfInventoryCode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This contains a display string that defines the inventory
+ code for this board. This is an optional value; if there is
+ no inventory code, The unit will respond with a null string.
+ Once an inventory code has been set, it should be kept in
+ non-volatile memory. The unit should only allow this object
+ to be set when it is in the 'configuration' mode. There is
+ no specification of the internal format of the inventory
+ Code."
+ REFERENCE " -- "
+ ::= { identIfExtensionEntry 5 }
+
+
+
+ identIfFirmwareVersion1 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Within a product, there may be several identifiers of such
+ firmware, boot proms, kernel versions, flash versions, etc.
+ This field (and the 3 that follow) are used to hold the
+ identification of these items. These values must be entered
+ into the board at the time of manufacturing. Unused fields
+ are reported as null values. These fields are available to
+ the network manager for applications that keep track of the
+ firmware related identification. There is no specification
+ of the internal format of firmware version identifiers."
+ REFERENCE " -- "
+ ::= { identIfExtensionEntry 6 }
+
+
+ identIfFirmwareVersion2 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Firmware related identification field # 2."
+ REFERENCE " -- "
+ ::= { identIfExtensionEntry 7 }
+
+
+ identIfFirmwareVersion3 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Firmware related identification field # 3."
+ REFERENCE " -- "
+ ::= { identIfExtensionEntry 8 }
+
+
+ identIfFirmwareVersion4 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Firmware related identification field # 4"
+ REFERENCE " -- "
+ ::= { identIfExtensionEntry 9 }
+
+
+ identIfSlotId OBJECT-TYPE
+ SYNTAX INTEGER (1..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This variable identifies the board slot."
+ REFERENCE " -- "
+ DEFVAL { 2147483647 }
+ ::= { identIfExtensionEntry 10 }
+
+
+ identIfCommand OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ unspecified(1),
+ reset(2),
+ restart(3),
+ halt(4)
+ }
+
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This is the command to be executed by the resource
+ managed by the agent.
+ The value unspecified(10 is always returned on SNMP
+ Get/GetNext while the other values are set by the manager
+ and executed by the resource."
+ REFERENCE " -- "
+ ::= { identIfExtensionEntry 11 }
+
+
+ identIfAdministrativeState OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ locked(1),
+ unlocked(2),
+ shuttingDown(3)
+ }
+
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ " The current Adminsitrative state of the interface as defined in
+ ISO/IEC 10164-2."
+ REFERENCE " -- "
+ ::= { identIfExtensionEntry 12 }
+
+
+ identIfOperationalState OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ enabled(1),
+ disabled(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ " The current Operational state of the interface as defined in
+ ISO/IEC 10164-2"
+ REFERENCE " -- "
+ ::= { identIfExtensionEntry 13 }
+
+
+ identIfAlarmStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ underRepair(1),
+ critical(2),
+ major(3),
+ minor(4),
+ alarmOutstanding(5),
+ idle(6)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ " This object defines the Alarm status of the interface
+ as defined in ISO/IEC 10164-2 and state-machine"
+ REFERENCE " -- "
+ ::= { identIfExtensionEntry 14 }
+
+
+ identIfAvailabilityStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ inTest(1),
+ failed(2),
+ powerOff(3),
+ offLine(4),
+ offDuty(5),
+ dependency(6),
+ degraded(7),
+ notInstalled(8),
+ logFull(9),
+ available(10)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ " This object controls the Availability status of the interface
+ as defined in ISO/IEC 10164-2 and state-machine"
+ REFERENCE " -- "
+ ::= { identIfExtensionEntry 15 }
+
+
+ identIfSpecific OBJECT-TYPE
+ SYNTAX OBJECT IDENTIFIER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ " The object identifier of a board type specific
+ extension to the ifTable if necessary. Otherwise,
+ identIfSpecific is set to {0 0}."
+ REFERENCE " -- "
+ ::= { identIfExtensionEntry 16 }
+
+
+ identIfEntryStatus OBJECT-TYPE
+ SYNTAX EntryStatus
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object is used to create, delete or
+ modify a row in this table. To create a
+ a new network element, this object is initially
+ set to 'createRequest'. After completion of the
+ configuration of the new entry, the manager
+ must set the appropriate instance of this object
+ to the value valid(1) or aborts, setting this object
+ to invalid(4). This object must not be set to
+ 'active' unless the following columnar objects
+ exist in this row:
+ identIfExtensionIndex
+ identIfSerialNumber
+ identIfHardwareVersion
+ identIfInventoryCode
+ identIfFirmwareVersion1
+ identIfSpecific
+ To delete an existing entry in this table,
+ the manager must set the appropriate
+ instance of this object to the value invalid(4).
+ Creation of an instance of this object has the
+ effect of creating the supplemental object instances
+ to complete the conceptual row. An existing instance
+ of this entry cannot be created. If circumstances
+ occur which cause an entry to become invalid, the
+ agent modifies the value of the appropriate instance
+ of this object to invalid(4). Whenever, the value of
+ this object for a particular entry becomes
+ invalid(4), the conceptual row for that instance may
+ be removed from the table at any time, either
+ immediately or subsequently."
+ DEFVAL { valid }
+ ::= { identIfExtensionEntry 17 }
+
+
+
+ identUnitModel OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This contains the model of the product. For example,
+ the ITEM-1000 would contain 'ITEM1000'. "
+ REFERENCE " -- "
+ ::= { bcsIdent 15 }
+
+
+
+
+END