summaryrefslogtreecommitdiff
path: root/MIBS/arris/DOCS-TEST-MIB
diff options
context:
space:
mode:
authorDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
committerDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
commit98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch)
tree9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/arris/DOCS-TEST-MIB
downloadmibs-main.tar.gz
mibs-main.zip
Initial commitHEADmain
Diffstat (limited to 'MIBS/arris/DOCS-TEST-MIB')
-rw-r--r--MIBS/arris/DOCS-TEST-MIB182
1 files changed, 182 insertions, 0 deletions
diff --git a/MIBS/arris/DOCS-TEST-MIB b/MIBS/arris/DOCS-TEST-MIB
new file mode 100644
index 0000000..ef1a5a2
--- /dev/null
+++ b/MIBS/arris/DOCS-TEST-MIB
@@ -0,0 +1,182 @@
+DOCS-TEST-MIB DEFINITIONS ::= BEGIN
+
+ IMPORTS
+ MODULE-IDENTITY,
+ OBJECT-TYPE,
+ -- do not import BITS,
+ Integer32,
+ enterprises
+ FROM SNMPv2-SMI
+ TEXTUAL-CONVENTION,
+ TruthValue
+ FROM SNMPv2-TC
+ OBJECT-GROUP,
+ MODULE-COMPLIANCE
+ FROM SNMPv2-CONF;
+
+
+-- These are the defined Cablelabs OID paths. Not all are needed for the Test MIB,
+-- but included here for sake of completeness.
+cableLabs OBJECT IDENTIFIER ::= { enterprises 4491 }
+clabFunction OBJECT IDENTIFIER ::= { cableLabs 1 }
+clabFuncMib2 OBJECT IDENTIFIER ::= { clabFunction 1 }
+clabFuncProprietary OBJECT IDENTIFIER ::= { clabFunction 2 }
+clabProject OBJECT IDENTIFIER ::= { cableLabs 2 }
+clabProjDocsis OBJECT IDENTIFIER ::= { clabProject 1 }
+clabProjPacketCable OBJECT IDENTIFIER ::= { clabProject 2 }
+clabProjOpenCable OBJECT IDENTIFIER ::= { clabProject 3 }
+clabProjCableHome OBJECT IDENTIFIER ::= { clabProject 4 }
+
+
+docsTestMIB MODULE-IDENTITY
+ LAST-UPDATED "0203150000Z" -- March 15, 2002
+ ORGANIZATION "DOCSIS 2.0 ATP Working Group"
+ CONTACT-INFO
+ " David Raftus
+ Postal: Imedia Semiconductor
+ 340 Terry Fox Drive, Suite 202
+ Ottawa Ontario
+ Canada
+ Phone: +1 613 592 1052
+ E-mail: david.raftus@imedia.com
+
+ DOCSIS 2.0 ATP Working Group
+ General Discussion: docsis-20@cablelabs.com,
+ docsis-20-atp@cablelabs.com"
+ DESCRIPTION
+ "This is the MIB Module supporting programmable test features
+ for DOCSIS 2.0 compliant Cable Modems (CM) and Cable Modem
+ Termination Systems (CMTS)."
+ -- 4491 is the IANA Cablelabs enterprise number
+ ::= { clabProjDocsis 12 }
+
+
+
+-- Textual Conventions
+-- none required yet - dave - leave as a placeholder
+
+
+-- Mapping path to the test mib.
+--
+docsTestMibObjects OBJECT IDENTIFIER ::= { docsTestMIB 1 }
+docsTestBaseObjects OBJECT IDENTIFIER ::= { docsTestMibObjects 1 }
+docsTestSetupObjects OBJECT IDENTIFIER ::= { docsTestMibObjects 2 }
+
+--
+-- docsTestBaseObjects
+--
+-- These objects indicate the capability and current status of the
+-- programmable test features on the CM/CMTS.
+--
+
+docsTestCapability OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the ability of this device to support the
+ programmable features identified by the TYPE field from
+ the CM/CMTS TLV table in [17] and section 3.1.2.
+ Each octet within this octet string represents eight tests.
+ For example, the first octet represents tests one through eight
+ as identified by the TYPE field."
+ ::= { docsTestBaseObjects 1 }
+
+docsTestStatus OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the current operating status of tests initiated
+ through the docsTestSetupObjects. The octet representation is
+ identical to that used by docsTestCapability. A bit representation
+ of one indicates that a test is currently active, while zero
+ indicates the test is inactive or has completed."
+ ::= { docsTestBaseObjects 2 }
+
+
+--
+-- docsTestSetupObjects
+--
+-- These objects setup the test parameters ands initiate the test.
+--
+
+docsTestType OBJECT-TYPE
+ SYNTAX Integer32 (0..1023)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Corresponds to the TYPE field from the CM/CMTS TLV Table
+ in [17] and section 3.1.2. The default value of zero indicates
+ no test has yet been initiated.
+ A WrongValueError should be returned in response to a write
+ request for a test not supported by the device. A read request
+ will return the docsTestType value last successfully written,
+ whether that test is active or inactive."
+ DEFVAL { 0 }
+ ::= { docsTestSetupObjects 1 }
+
+docsTestData OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Corresponds to the LENGTH and VALUE fields from the CM/CMTS TLV
+ Table in [17] and section 3.1.2. A read request will return the
+ docsTestData value last successfully written, whether that test
+ is active or inactive."
+ ::= { docsTestSetupObjects 2 }
+
+docsTestEnable OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Used to initiate or stop the tests setup through the docsTestType
+ and docsTestData objects.
+ A CommitFailedError should be returned in response to a TRUE
+ Write request if the values in docsTestType and docsTestData are
+ incompatible, or a test could not be initiated for any other
+ reason."
+ ::= { docsTestSetupObjects 3 }
+
+
+
+
+-- Compliance statements
+
+docsTestConformance OBJECT IDENTIFIER ::= { docsTestMIB 2 }
+docsTestCompliances OBJECT IDENTIFIER ::= { docsTestConformance 1 }
+docsTestGroups OBJECT IDENTIFIER ::= { docsTestConformance 2 }
+
+
+docsTestBasicCompliance MODULE-COMPLIANCE
+ STATUS current
+ DESCRIPTION
+ "The compliance statement for devices that implement
+ the DOCSIS compliant programmable test features."
+
+MODULE -- docsTestMib
+
+-- unconditionally mandatory groups
+MANDATORY-GROUPS {
+ docsTestGroup
+ } ::= { docsTestCompliances 1 }
+
+
+docsTestGroup OBJECT-GROUP
+ OBJECTS {
+ docsTestCapability,
+ docsTestStatus,
+ docsTestType,
+ docsTestData,
+ docsTestEnable
+ }
+ STATUS current
+ DESCRIPTION
+ "Group of objects implemented in both Cable Modems and
+ Cable Modem Termination Systems."
+ ::= { docsTestGroups 1 }
+
+
+END