diff options
| author | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
|---|---|---|
| committer | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
| commit | 98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch) | |
| tree | 9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/asentria/SITEBOSS-550-STD-MIB | |
| download | mibs-main.tar.gz mibs-main.zip | |
Diffstat (limited to 'MIBS/asentria/SITEBOSS-550-STD-MIB')
| -rw-r--r-- | MIBS/asentria/SITEBOSS-550-STD-MIB | 25637 |
1 files changed, 25637 insertions, 0 deletions
diff --git a/MIBS/asentria/SITEBOSS-550-STD-MIB b/MIBS/asentria/SITEBOSS-550-STD-MIB new file mode 100644 index 0000000..7c6f742 --- /dev/null +++ b/MIBS/asentria/SITEBOSS-550-STD-MIB @@ -0,0 +1,25637 @@ +-- SiteBoss 550 MIB + +-- v 4.66 Mar 8 2019 + +-- Copyright (c) 2019 by Asentria Corporation. All rights reserved. + + +SITEBOSS-550-STD-MIB DEFINITIONS ::= BEGIN + +IMPORTS + DisplayString + FROM SNMPv2-TC + IpAddress, TimeTicks, Integer32, + MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-TYPE + FROM SNMPv2-SMI + asentria + FROM ASENTRIA-ROOT-MIB; + +--*************************************************************************************** +--MODULE IDENTITY +--*************************************************************************************** + + s550 MODULE-IDENTITY + LAST-UPDATED "201903081530Z" + ORGANIZATION "Asentria Corporation" + CONTACT-INFO + "Phone: 206-344-8800 + Fax: 206-344-2116 + Email: support@asentria.com" + DESCRIPTION + "MIB module for managing Asentria SiteBoss 550" + + REVISION "201903081530Z" + DESCRIPTION + "-v4.66 + -Add objects for Power Meter line-to-line voltage (OMX-2143) and modified OID numbering for ACMON. + -Applicable since unit version 2.11.760." + + + REVISION "201902111345Z" + DESCRIPTION + "-v4.65 + -Added objects for Site Security (OMX-2021). + -Applicable since unit version 2.11.760." + + REVISION "201710311049Z" + DESCRIPTION + "-v4.64 + -Added objects for Bard HVAC controller (OMX-1852). + -Applicable since unit version 2.11.550." + + REVISION "201705251028Z" + DESCRIPTION + "-v4.63 + -Added trap 545 and 548 to the mibs + -Applicable since unit version 2.11.500." + + REVISION "201704260945Z" + DESCRIPTION + "-v4.62 + -Added ACMON Alarm datetime to the mibs + -Applicable since unit version 2.11.490." + + REVISION "201603160850Z" + DESCRIPTION + "-v4.61 + -Fixed missing IP Camera trap notifications + -Applicable since unit version 2.11.210." + + REVISION "201603150500Z" + DESCRIPTION + "-v4.60 + -Replace existing sensor .type setting with new system .group + -Added Objects espcCCGroup, espcTempGroup, espcHumidGroup, + espcAIGroup espcOutputGroup + -Applicable since unit version 2.11.210." + + + REVISION "201601070459Z" + DESCRIPTION + "-v4.59 + -Added Event Sensor Alias and Class OID for event states. + -Added Fuel Sensor Fuel Type. + -Applicable since unit version 2.11.140." + + + REVISION "201510290458Z" + DESCRIPTION + "-v4.58 + -Allow read access for battery backup - percent charge and running + status. + -Add trap for power up/down or running on battery/main + -Applicable since unit version 2.10.930." + + REVISION "201504030457Z" + DESCRIPTION + "-v4.57 + -Allow read access for serial number, product name, software version + -Add trap for General Sensor Unresponsive (OMX-1257) + -Applicable since unit version 2.10.700." + + REVISION "201503200456Z" + DESCRIPTION + "-v4.56 + -Removed non-essential Bard settings (OMX-1203). + -Removed wirelessPIN and scSecret objects (OMX-1064). + -Added HVAC status and settings objects. + -Added ACDM wiegand point object. + -Applicable since unit version 2.10.670." + + REVISION "201412110455Z" + DESCRIPTION + "-v4.55 + -Changed analog-input fuel sensor objects from Integer32 to DisplayString (OMX-1177). + -Added missing ipv6DefaultRouter object (OMX-1175). + -Applicable since unit version 2.10.580." + + REVISION "201410160454Z" + DESCRIPTION + "-v4.54 + -Added espcAIDisplayFormat object (OMX-1112). + -Removed espcAIPolarity, espcAIConvHighSign, espcAIConvLowSign objects (OMX-1113). + -Applicable since unit version 2.10.460." + + REVISION "201410030453Z" + DESCRIPTION + "-v4.53 + -Changed analog input objects from Integer32 to DisplayString. + -Applicable since unit version 2.10.460." + + REVISION "201409100452Z" + DESCRIPTION + "-v4.52 + -Added dnp3 and telemetry branches (OMX-454). + -Applicable since unit version 2.10.460." + + REVISION "201408140451Z" + DESCRIPTION + "-v4.51 + -Fixed description for wirelessConnIP objects (OMX-1061). + -Applicable since unit version 2.10.390." + + REVISION "201407030450Z" + DESCRIPTION + "-v4.50 + -Fixed wirelessIdleTimeout (OMX-1037). + -Fixed CPE status objects (OMX-1036). + -Applicable since unit version 2.10.390." + + REVISION "201406240449Z" + DESCRIPTION + "-v4.49 + -Fixed CPE status objects. + -Applicable since unit version 2.10.340." + + REVISION "201406170448Z" + DESCRIPTION + "-v4.48 + -Added various missing objects (OMX-751). + -Added CPE objects (OMX-162). + -Added ACDM objects (OMX-683). + -Applicable since unit version 2.10.340." + + REVISION "201404110447Z" + DESCRIPTION + "-v4.47 + -Clarified relay and power output function and documentation (OMX-926). + -Applicable since unit version 2.10.300." + + REVISION "201401170146Z" + DESCRIPTION + "-v4.46 + -Added IPv6 objects (OMX-705). + -Added power distribution objects (powerDistributionStatus branch) (OMX-708). + -Fixed ipRestrictionMask wrong type (OMX-743). + -Added ftpPushPermissions (OMX-737). + -Added snmpProxy objects (OMX-747). + -Applicable since unit version 2.10.150." + + REVISION "201312160445Z" + DESCRIPTION + "-v4.45 + -Changed evHVACStatus branch OIDs (OMX-702). + -Applicable since unit version 2.10.130." + + REVISION "201312040444Z" + DESCRIPTION + "-v4.44 + -Added fsGenEnable (OMX-661). + -Applicable since unit version 2.10.110." + + REVISION "201310300443Z" + DESCRIPTION + "-v4.43 + -Added genSetRelayTable for multiple genset ignition relays (OMX-577). + -Added genSetCCDelay object (OMX-589). + -Added webXMLProxy branch (OMX-629). + -Applicable since unit version 2.09.625." + + REVISION "201310040442Z" + DESCRIPTION + "-v4.42 + -Added objects for Emerson Vortex Power System (OMX-578). + -Applicable since unit version 2.09.624." + + REVISION "201309260441Z" + DESCRIPTION + "-v4.41 + -Added objects for Bard HVAC controller (OMX-563). + -Applicable since unit version 2.09.623." + + REVISION "201308010440Z" + DESCRIPTION + "-v4.40 + -Added missing trapEventTypeNumber available values in description (OMX-437). + -Applicable since unit version 2.09.560." + + REVISION "201307170439Z" + DESCRIPTION + "-v4.39 + -Corrected snmpPBufferAllPeriod object. + -Applicable since unit version 2.09.560." + + REVISION "201307020438Z" + DESCRIPTION + "-v4.38 + -Added snmpPoll objects (OMX-394). + -Applicable since unit version 2.09.560." + + REVISION "201306120437Z" + DESCRIPTION + "-v4.37 + -Renamed EX10 to Ethernet Expansion (OMX-364) + -Applicable since unit version 2.09.510." + + REVISION "201305280436Z" + DESCRIPTION + "-v4.36 + -Fixed incorrect SYNTAX for sysCharMask (OMX-328). + -Added evGlobal branch (OMX-228). + -Applicable since unit version 2.09.500." + + REVISION "201305100435Z" + DESCRIPTION + "-v4.35 + -Fixed incorrect SYNTAX statements for various objects (OMX-314). + -Applicable since unit version 2.09.380." + + REVISION "201304100434Z" + DESCRIPTION + "-v4.34 + -Added non-weekly job scheduling objects (OMX-252). + -Applicable since unit version 2.09.310." + + REVISION "201303150433Z" + DESCRIPTION + "-v4.33 + -Renamed sysLocation branch to sysLoc (OMX-198). + -Applicable since unit version 2.09.240." + + REVISION "201303140432Z" + DESCRIPTION + "-v4.32 + -Added snmpProxy branch (OMX-190). + -Applicable since unit version 2.09.280." + + REVISION "201302060431Z" + DESCRIPTION + "-v4.31 + -Added ex10 branch. + -Renamed telnet* objects. + -Applicable since unit version 2.09.240." + + REVISION "201301140430Z" + DESCRIPTION + "-v4.30 + -Added evReset branch and associated notification (OMX-83). + -Applicable since unit version 2.09.220." + + REVISION "201211190429Z" + DESCRIPTION + "-v4.29 + -Added sysFileTransfer and sysUpdate objects. (BN 4632) + -Fixed backwards pppRoutingEnable/ethRoutingEnable comments. (BN 4620) + -Applicable since unit version 2.09.120." + + REVISION "201208220428Z" + DESCRIPTION + "-v4.28 + -Added additional AC power monitor items." + + REVISION "201208020427Z" + DESCRIPTION + "-v4.27 + -Removed non-weekly job schedule objects." + + REVISION "201206120425Z" + DESCRIPTION + "-v4.25 + -Removed user credentials objects." + + REVISION "201205010424Z" + DESCRIPTION + "-v4.24 + -Added object for location. + -Fixed objects for Generator Exercising Non-Start event." + + REVISION "201204300423Z" + DESCRIPTION + "-v4.23 + -Added objects for fuel sensor sudden/slow change." + + REVISION "201204120422Z" + DESCRIPTION + "-v4.22 + -Added objects for job scheduling and generator exercising." + + REVISION "201204090421Z" + DESCRIPTION + "-v4.21 + -Added eth2WanRoutingEnable object." + + REVISION "201204050420Z" + DESCRIPTION + "-v4.20 + -Added combined eventsensor status objects." + + REVISION "201203060419Z" + DESCRIPTION + "-v4.19 + -Added objects and trap definitions for fuel sensor and AC power monitor." + + REVISION "201201160902Z" + DESCRIPTION + "-v4.18 + -Jumped to 4.xx Asentria version series. The version 4 + series officially may improve compatibility with certain + NMS installations by grouping all notifications in a + dedicated branch. + -Added stockScriptTrap notification definition." + + REVISION "201109150900Z" + DESCRIPTION + "-v1.17 + -Moved notification definitions to dedicated branch." + + REVISION "201108080900Z" + DESCRIPTION + "-v1.16 + -Added s550StockOutputTrap notification definition." + + REVISION "201108010900Z" + DESCRIPTION + "-v1.15 + -Added evMgmtReprocess object." + + REVISION "201107080900Z" + DESCRIPTION + "-v1.14 + -Added wirelessModemStatus branch." + + REVISION "201101050900Z" + DESCRIPTION + "-v1.13 + -Added espcCCNormalThreshold object." + + REVISION "201011030900Z" + DESCRIPTION + "-v1.12 + -Changed deadband, threshold, and current values for temperature + sensors from integer to floating-point type. This means the + SNMP object type for the temperature settings (deadbands and + thresholds) changed from Integer32 to DisplayString. + -Fixed bug where SNMP integer range defined in the MIB for + trapIncludedValue was 16-bit instead of 32-bit." + + REVISION "201008240900Z" + DESCRIPTION + "-v1.11 + -Fixed bug where some stock traps had too few varbinds declared. + -Removed useless trap definitions." + + REVISION "201003160900Z" + DESCRIPTION + "-v1.10 + -Removed useless objects consoleInlineHsk, consoleBaud, consoleFormat, consoleHsk." + + REVISION "201001190900Z" + DESCRIPTION + "-v1.09 + -Increased range for esPointValueInt" + + REVISION "200811210900Z" + DESCRIPTION + "-v1.08 + -Added scripting variable objects." + + REVISION "200811120900Z" + DESCRIPTION + "-v1.07 + -Corrected comments for stock trap definitions." + + REVISION "200806090900Z" + DESCRIPTION + "-v1.06 + -Added sysLocation branch. + -Updated phone numbers in contact info block." + + REVISION "200806021100Z" + DESCRIPTION + "-v1.05 + -Added SitePath CPE routing authorization requested stock trap." + + REVISION "200805151500Z" + DESCRIPTION + "-v1.04 + -Added pager settings" + + REVISION "200805081426Z" + DESCRIPTION + "-v1.03 + -Fixed issue where commented OIDs used wrong module identity number" + + REVISION "200804221652Z" + DESCRIPTION + "-v1.02 + -Added missing wireless objects + -Removed wirelessBaud object which broke mib walk + -Fixed issue where snmpNotificationTx branch was defined wrong." + + REVISION "200803211650Z" + DESCRIPTION + "-v1.01 + -Added missing CPEDown/VPNGDow notification definitions" + + REVISION "200712070030Z" + DESCRIPTION + "-v1.00 + -Branched new MIB off of SiteBoss 570 MIB" + + ::= { asentria 10 } + --1.3.6.1.4.1.3052.10 + + +--*************************************************************************************** +--Concise MIB View: Top Level Branches +--*************************************************************************************** + +-- status .1 +-- eventSensorStatus .1.1 +-- esPointTable .1.1.1 +-- dataEventStatus .1.2 +-- deStatusTable .1.2.1 +-- modemStatus .1.3 +-- modemCLIDLogTable .1.4 +-- powerDistributionStatus .1.5 +-- fuelSensorStatus .1.6 +-- fsStatusTable .1.6.1 +-- wirelessModemStatus .1.7 +-- acPowerMonitorStatus .1.8 +-- acpmStatusTable .1.8.1 +-- evHVACStatus .1.11 +-- evHVACStatusBard .1.11.2 +-- evHVACStatusAsentria .1.11.3 +-- evHVACStatusAirsys .1.11.4 +-- backupBattStatus .1.12 +-- liBattStatus .1.12.1 +-- config .2 +-- eventSensorBasics .2.1 +-- esNumberEventSensors .2.1.1 +-- esTable .2.1.2 +-- esNewSensors .2.1.3 +-- eventSensorPointConfig .2.2 +-- esPointConfigTempTable .2.2.1 +-- esPointConfigCCTable .2.2.2 +-- esPointConfigHumidTable .2.2.3 +-- esPointConfigAITable .2.2.5 +-- esPointConfigOutputTable .2.2.6 +-- serialPorts .2.3 +-- numberPorts .2.3.1 +-- portConfigTable .2.3.2 +-- network .2.4 +-- interface .2.4.1 +-- defaultRouter .2.4.2 +-- dnsTable .2.4.3 +-- hostname .2.4.4 +-- hostTable .2.4.5 +-- ncpDuplex .2.4.6 +-- ncpTimeout .2.4.7 +-- snmp .2.4.8 +-- ftpPush .2.4.9 +-- ppp .2.4.10 +-- routing .2.4.11 +-- netSecurity .2.4.12 +-- rts .2.4.13 +-- trap .2.4.14 +-- routeTest .2.4.15 +-- gprs .2.4.16 +-- email .2.4.17 +-- netAdvanced .2.4.18 +-- web .2.4.19 +-- ethExpan .2.4.20 +-- ipv6 .2.4.21 +-- cpe .2.4.22 +-- dnp3 .2.4.23 +-- modem .2.5 +-- time .2.8 +-- clock .2.8.1 +-- console .2.10 +-- unitSecurity .2.11 +-- secCore .2.11.1 +-- secUserTable .2.11.2 +-- secFactory .2.11.3 +-- secSSH .2.11.4 +-- secVPN .2.11.5 +-- event .2.12 +-- evCore .2.12.1 +-- evData .2.12.2 +-- evNoData1 .2.12.3 +-- evNoData2 .2.12.4 +-- evSched1 .2.12.5 +-- evSched2 .2.12.6 +-- evShskLowTable .2.12.7 +-- evShskHighTable .2.12.8 +-- evNoSensor .2.12.9 +-- fuelSensor .2.12.11 +-- fuelSensorGeneralTable .2.12.11.1 +-- fuelSensorTankTable .2.12.11.2 +-- fuelSensorCustomTankTable .2.12.11.3 +-- fuelSensorVolumeTable .2.12.11.4 +-- fuelSensorDisconnectTable .2.12.11.5 +-- fuelSensorSuddenChangeTable .2.12.11.6 +-- fuelSensorSlowChangeTable .2.12.11.7 +-- acPowerMonitor .2.12.12 +-- evReset .2.12.16 +-- evGlobal .2.12.18 +-- evHVAC .2.12.19 +-- evHVACGeneral .2.12.19.1 +-- evHVACBard .2.12.19.2 +-- evHVACAsentria .2.12.19.3 +-- evHVACAirsys .2.12.19.4 +-- evEvps .2.12.20 +-- accessControl .2.12.21 +-- telemetry .2.12.22 +-- siteSecurity .2.12.23 +-- action .2.14 +-- actionCallNumberTable .2.14.1 +-- actionPagerTable .2.14.2 +-- actionSched .2.14.3 +-- actionAsentria .2.14.4 +-- actionHostTable .2.14.6 +-- actionEmailTable .2.14.7 +-- actionParseError .2.14.8 +-- sys .2.16 +-- sysTime .2.16.1 +-- sysPT .2.16.2 +-- sysMTU .2.16.3 +-- sysAnswerString .2.16.4 +-- sysEventFileID .2.16.6 +-- sysEscapeCharacter .2.16.7 +-- sysTimeStamp .2.16.8 +-- sysLog .2.16.9 +-- sysCRDB .2.16.10 +-- sysCharMask .2.16.11 +-- sysPrompt .2.16.12 +-- sysBootStatus .2.16.13 +-- sysLoc .2.16.14 +-- sysAssetMgmt .2.16.15 +-- sysFileTransfer .2.16.17 +-- sysUpdate .2.16.18 +-- auditLog .2.17 +-- scripting .2.18 +-- scrGlobalEnable .2.18.1 +-- scrDTRCtrlPortEnableTable .2.18.2 +-- scrTable .2.18.3 +-- scrVolatileStringTable .2.18.4 +-- scrVolatileIntTable .2.18.5 +-- scrNonVolatileStringTable .2.18.6 +-- scrNonVolatileIntTable .2.18.7 +-- generator .2.19 +-- genSet .2.19.1 +-- genSetRelay .2.19.1.2 +-- genSetCc .2.19.1.3 +-- genRun .2.19.2 +-- genRunNonstartEvent .2.19.2.7 +-- calendar .2.20 +-- productIds .3 +-- siteName 3.1 +-- thisProduct .3.2 +-- stockTrapString .3.3 +-- trapEventTypeNumber .3.4 +-- trapEventTypeName .3.5 +-- trapIncludedValue .3.6 +-- trapIncludedString .3.7 +-- trapTypeString .3.8 +-- trapEventClassNumber .3.9 +-- trapEventClassName .3.10 +-- keyInterface .4.0 + +--*************************************************************************************** +--Complete MIB View: All Objects +--*************************************************************************************** + +-- status .1 +-- eventSensorStatus .1.1 +-- esPointTable .1.1.1 +-- esPointEntry .1.1.1.1 +-- esIndexES .1.1.1.1.1 +-- esIndexPC .1.1.1.1.2 +-- esIndexPoint .1.1.1.1.3 +-- esPointName .1.1.1.1.4 +-- esPointInEventState .1.1.1.1.5 +-- esPointValueInt .1.1.1.1.6 +-- esPointValueStr .1.1.1.1.7 +-- esPointTimeLastChange .1.1.1.1.8 +-- esPointTimetickLastChange .1.1.1.1.9 +-- esPointAliasValueStr .1.1.1.1.10 +-- esPointClassValueStr .1.1.1.1.11 +-- dataEventStatus .1.2 +-- deStatusTable .1.2.1 +-- deStatusEntry .1.2.1.1 +-- deStatusIndex .1.2.1.1.1 +-- deStatusName .1.2.1.1.2 +-- deStatusCounter .1.2.1.1.3 +-- deStatusThreshold .1.2.1.1.4 +-- modemStatus .1.3 +-- modemCLIDLogTable .1.4 +-- modemCLIDLogEntry .1.4.1 +-- modemCLIDLogIndex .1.4.1.1 +-- modemCLIDLogNumber .1.4.1.2 +-- powerDistributionStatus .1.5 +-- pdConfig .1.5.1 +-- pdNextGen .1.5.4 +-- pdnTable .1.5.4.1 +-- pdnEntry .1.5.4.1.1 +-- pdnIndexPD .1.5.4.1.1.1 +-- pdnIndexOutput .1.5.4.1.1.2 +-- pdnConfig .1.5.4.1.1.3 +-- pdnMainCurrentInEventState .1.5.4.1.1.4 +-- pdnMainCurrentValue .1.5.4.1.1.5 +-- pdnMainCurrentValueStr .1.5.4.1.1.6 +-- pdnMainCurrentDeadband .1.5.4.1.1.7 +-- pdnMainCurrentVHighCurrent .1.5.4.1.1.8 +-- pdnMainCurrentHighCurrent .1.5.4.1.1.9 +-- pdnMainCurrentLowCurrent .1.5.4.1.1.10 +-- pdnMainCurrentVLowCurrent .1.5.4.1.1.11 +-- pdnMainVoltageInEventState .1.5.4.1.1.12 +-- pdnMainVoltageValue .1.5.4.1.1.13 +-- pdnMainVoltageValueStr .1.5.4.1.1.14 +-- pdnMainVoltageDeadband .1.5.4.1.1.15 +-- pdnMainVoltageVHighVoltage .1.5.4.1.1.16 +-- pdnMainVoltageHighVoltage .1.5.4.1.1.17 +-- pdnMainVoltageLowVoltage .1.5.4.1.1.18 +-- pdnMainVoltageVLowVoltage .1.5.4.1.1.19 +-- pdnMainPowerValue .1.5.4.1.1.20 +-- pdnMainPowerValueStr .1.5.4.1.1.21 +-- pdnOutputCurrentInEventState .1.5.4.1.1.22 +-- pdnOutputCurrentValue .1.5.4.1.1.23 +-- pdnOutputCurrentValueStr .1.5.4.1.1.24 +-- pdnOutputCurrentDeadband .1.5.4.1.1.25 +-- pdnOutputCurrentVHighCurrent .1.5.4.1.1.26 +-- pdnOutputCurrentHighCurrent .1.5.4.1.1.27 +-- pdnOutputCurrentLowCurrent .1.5.4.1.1.28 +-- pdnOutputCurrentVLowCurrent .1.5.4.1.1.29 +-- pdnOutputFuseInEventState .1.5.4.1.1.30 +-- pdnOutputFuseValueStr .1.5.4.1.1.31 +-- pdnMainCombinedStatus .1.5.4.1.1.32 +-- pdnOutputCombinedStatusBlock1 .1.5.4.1.1.33 +-- pdnOutputCombinedStatusBlock2 .1.5.4.1.1.34 +-- pdnDeviceCurrentValue .1.5.4.1.1.35 +-- pdnDeviceCurrentValueStr .1.5.4.1.1.36 +-- pdSystem .1.5.5 +-- pdSystemCurrent .1.5.5.1 +-- pdSystemPower .1.5.5.2 +-- fuelSensorStatus .1.6 +-- fsStatusTable .1.6.1 +-- fsStatusEntry .1.6.1.1 +-- fsStatusIndex .1.6.1.1.1 +-- fsStatusName .1.6.1.1.2 +-- fsStatusDeviceState .1.6.1.1.3 +-- fsStatusVolumeValueString .1.6.1.1.4 +-- fsStatusVolumePercentLevel .1.6.1.1.7 +-- fsStatusVolumeInEventState .1.6.1.1.8 +-- fsStatusCombined .1.6.1.1.9 +-- wirelessModemStatus .1.7 +-- wmsStatus .1.7.1 +-- wmsSignal .1.7.2 +-- wmsRSSI .1.7.3 +-- wmsBER .1.7.4 +-- wmsUpdated .1.7.5 +-- wmsRegistration .1.7.6 +-- wmsLAC .1.7.7 +-- wmsCellID .1.7.8 +-- wmsIMSI .1.7.9 +-- wmsPhnum .1.7.10 +-- wmsLocalIP .1.7.11 +-- wmsMgfID .1.7.12 +-- wmsModelID .1.7.13 +-- wmsIMEI .1.7.14 +-- wmsRevID .1.7.15 +-- wmsNetName .1.7.16 +-- wmsGPRSStatus .1.7.17 +-- wmsBand .1.7.18 +-- wmsChannel .1.7.19 +-- wmsCountryCode .1.7.20 +-- wmsNetCode .1.7.21 +-- wmsPLMNColor .1.7.22 +-- wmsBScolor .1.7.23 +-- wmsMpRACH .1.7.24 +-- wmsMinRxLevel .1.7.25 +-- wmsBaseCoeff .1.7.26 +-- wmsSIMStatus .1.7.27 +-- wmsICCID .1.7.28 +-- wmsModemType .1.7.29 +-- acPowerMonitorStatus .1.8 +-- acpmStatusTable .1.8.1 +-- acpmStatusEntry .1.8.1.1 +-- acpmsIndex .1.8.1.1.1 +-- acpmsName .1.8.1.1.2 +-- acpmsAvgVoltageValueStr .1.8.1.1.3 +-- acpmsAvgVoltageMinStr .1.8.1.1.4 +-- acpmsAvgVoltageMaxStr .1.8.1.1.5 +-- acpmsAvgVoltageAvgStr .1.8.1.1.6 +-- acpmsAvgVoltageInEventState .1.8.1.1.7 +-- acpmsVoltagePhaseAValueStr .1.8.1.1.8 +-- acpmsVoltagePhaseBValueStr .1.8.1.1.9 +-- acpmsVoltagePhaseCValueStr .1.8.1.1.10 +-- acpmsVoltageL1L2Value .1.8.1.1.11 +-- acpmsVoltageL2L3Value .1.8.1.1.12 +-- acpmsVoltageL3L1Value .1.8.1.1.13 +-- acpmsAvgCurrentValueStr .1.8.1.1.14 +-- acpmsAvgCurrentMinStr .1.8.1.1.15 +-- acpmsAvgCurrentMaxStr .1.8.1.1.16 +-- acpmsAvgCurrentAvgStr .1.8.1.1.17 +-- acpmsAvgCurrentInEventState .1.8.1.1.18 +-- acpmsCurrentPhaseAValueStr .1.8.1.1.19 +-- acpmsCurrentPhaseBValueStr .1.8.1.1.20 +-- acpmsCurrentPhaseCValueStr .1.8.1.1.21 +-- acpmsFreqValueStr .1.8.1.1.22 +-- acpmsFreqMinStr .1.8.1.1.23 +-- acpmsFreqMaxStr .1.8.1.1.24 +-- acpmsFreqAvgStr .1.8.1.1.25 +-- acpmsFreqInEventState .1.8.1.1.26 +-- acpmsTRPValueStr .1.8.1.1.27 +-- acpmsTRPMinStr .1.8.1.1.28 +-- acpmsTRPMaxStr .1.8.1.1.29 +-- acpmsTRPAvgStr .1.8.1.1.30 +-- acpmsTRPInEventState .1.8.1.1.31 +-- acpmsRPPhaseAValueStr .1.8.1.1.32 +-- acpmsRPPhaseBValueStr .1.8.1.1.33 +-- acpmsRPPhaseCValueStr .1.8.1.1.34 +-- acpmsCombined .1.8.1.1.35 +-- acpmsTPFValueStr .1.8.1.1.36 +-- acpmsTPFMinStr .1.8.1.1.37 +-- acpmsTPFMaxStr .1.8.1.1.38 +-- acpmsTPFAvgStr .1.8.1.1.39 +-- acpmsTPFInEventState .1.8.1.1.40 +-- acpmsPFPhaseAValueStr .1.8.1.1.41 +-- acpmsPFPhaseBValueStr .1.8.1.1.42 +-- acpmsPFPhaseCValueStr .1.8.1.1.43 +-- acpmsTRcPValueStr .1.8.1.1.44 +-- acpmsTRcPMinStr .1.8.1.1.45 +-- acpmsTRcPMaxStr .1.8.1.1.46 +-- acpmsTRcPAvgStr .1.8.1.1.47 +-- acpmsRcPPhaseAValueStr .1.8.1.1.48 +-- acpmsRcPPhaseBValueStr .1.8.1.1.49 +-- acpmsRcPPhaseCValueStr .1.8.1.1.50 +-- acpmsTAPValueStr .1.8.1.1.51 +-- acpmsTAPMinStr .1.8.1.1.52 +-- acpmsTAPMaxStr .1.8.1.1.53 +-- acpmsTAPAvgStr .1.8.1.1.54 +-- acpmsAPPhaseAValueStr .1.8.1.1.55 +-- acpmsAPPhaseBValueStr .1.8.1.1.56 +-- acpmsAPPhaseCValueStr .1.8.1.1.57 +-- acpmsTotalEnergyWh .1.8.1.1.58 +-- acpmsTotalEnergyVAR .1.8.1.1.59 +-- acpmsTotalEnergyVA .1.8.1.1.60 +-- acmpsAvgVoltageAlarmDatetime .1.8.1.1.61 +-- acmpsAvgCurrentAlarmDatetime .1.8.1.1.62 +-- acmpsFreqAlarmDatetime .1.8.1.1.63 +-- acmpsRealPowerAlarmDatetime .1.8.1.1.64 +-- acmpsPowerFactorAlarmDatetime .1.8.1.1.65 +-- evHVACStatus .1.11 +-- evHVACStatusBard .1.11.2 +-- evHVACStatusBardSystem1 .1.11.2.1 +-- evHVACStatusBardSystem1Stage1 .1.11.2.1.1 +-- evHVACStatusBardSystem1Stage1Cooling .1.11.2.1.1.1 +-- evHVACStatusBardSystem1Stage2 .1.11.2.1.2 +-- evHVACStatusBardSystem1Stage2Cooling .1.11.2.1.2.1 +-- evHVACStatusBardSystem1Blower .1.11.2.1.3 +-- evHVACStatusBardSystem1Heating .1.11.2.1.4 +-- evHVACStatusBardSystem1Economizer .1.11.2.1.5 +-- evHVACStatusBardSystem2 .1.11.2.2 +-- evHVACStatusBardSystem2Stage1 .1.11.2.2.1 +-- evHVACStatusBardSystem2Stage1Cooling .1.11.2.2.1.1 +-- evHVACStatusBardSystem2Stage2 .1.11.2.2.2 +-- evHVACStatusBardSystem2Stage2Cooling .1.11.2.2.2.1 +-- evHVACStatusBardSystem2Blower .1.11.2.2.3 +-- evHVACStatusBardSystem2Heating .1.11.2.2.4 +-- evHVACStatusBardSystem2Economizer .1.11.2.2.5 +-- evHVACStatusBardTempAvg .1.11.2.3 +-- evHVACStatusBardTempLocal .1.11.2.4 +-- evHVACStatusBardTempRemote .1.11.2.5 +-- evHVACStatusBardTempRemote1 .1.11.2.5.1 +-- evHVACStatusBardTempRemote2 .1.11.2.5.2 +-- evHVACStatusBardDehumidification .1.11.2.6 +-- evHVACStatusBardLEDs .1.11.2.7 +-- evHVACStatusBardLEDsCooling .1.11.2.7.1 +-- evHVACStatusBardLEDsCooling1 .1.11.2.7.1.1 +-- evHVACStatusBardLEDsCooling2 .1.11.2.7.1.2 +-- evHVACStatusBardLEDsCooling3 .1.11.2.7.1.3 +-- evHVACStatusBardLEDsCooling4 .1.11.2.7.1.4 +-- evHVACStatusBardLEDsHeating .1.11.2.7.2 +-- evHVACStatusBardLEDsHeating1 .1.11.2.7.2.1 +-- evHVACStatusBardLEDsHeating2 .1.11.2.7.2.2 +-- evHVACStatusBardLEDsHeating3 .1.11.2.7.2.3 +-- evHVACStatusBardLEDsHeating4 .1.11.2.7.2.4 +-- evHVACStatusBardLEDsDeHumid .1.11.2.7.3 +-- evHVACStatusBardLEDsDeHumid1 .1.11.2.7.3.1 +-- evHVACStatusBardGenerator .1.11.2.8 +-- evHVACStatusBardAlarmBoardState .1.11.2.9 +-- evHVACStatusBardAlarmStatus .1.11.2.10 +-- evHVACStatusBardASSystem1 .1.11.2.10.1 +-- evHVACStatusBardASSystem1PowerLoss .1.11.2.10.1.1 +-- evHVACStatusBardASSystem1Lockout .1.11.2.10.1.2 +-- evHVACStatusBardASSystem2 .1.11.2.10.2 +-- evHVACStatusBardASSystem2PowerLoss .1.11.2.10.2.1 +-- evHVACStatusBardASSystem2Lockout .1.11.2.10.2.2 +-- evHVACStatusBardASFire .1.11.2.10.3 +-- evHVACStatusBardASTemp .1.11.2.10.4 +-- evHVACStatusBardASTempLowAlarm .1.11.2.10.4.1 +-- evHVACStatusBardASTempHighAlarm .1.11.2.10.4.2 +-- evHVACStatusBardASTempVHighAlarm .1.11.2.10.4.3 +-- evHVACStatusBardASFailure .1.11.2.10.5 +-- evHVACStatusBardConnState .1.11.2.11 +-- evHVACStatusAsentria .1.11.3 +-- evHVACStatusAsentriaSequenceTable .1.11.3.1 +-- evHVACStatusAsentriaSequenceEntry .1.11.3.1.1 +-- evHVACStatusAsentriaSequenceIndex .1.11.3.1.1.1 +-- evHVACStatusAsentriaSeqVentTime .1.11.3.1.1.2 +-- evHVACStatusAsentriaSeqCoolTime .1.11.3.1.1.3 +-- evHVACStatusAsentriaSeqHeatTime .1.11.3.1.1.4 +-- evHVACStatusAsentriaSeqIdleTime .1.11.3.1.1.5 +-- evHVACStatusAsentriaUnitTable .1.11.3.2 +-- evHVACStatusAsentriaUnitEntry .1.11.3.2.1 +-- evHVACStatusAsentriaUnitIndex .1.11.3.2.1.1 +-- evHVACStatusAsentriaUnitState .1.11.3.2.1.2 +-- evHVACStatusAsentriaUnitVentTime .1.11.3.2.1.3 +-- evHVACStatusAsentriaUnitCoolTime .1.11.3.2.1.4 +-- evHVACStatusAsentriaUnitHeatTime .1.11.3.2.1.5 +-- evHVACStatusAsentriaUnitIdleTime .1.11.3.2.1.6 +-- evHVACStatusAsentriaBackupEvent .1.11.3.3 +-- evHVACStatusAsentriaFireEvent .1.11.3.4 +-- evHVACStatusAsentriaTemp .1.11.3.5 +-- evHVACStatusAsentriaTempOut .1.11.3.5.1 +-- evHVACStatusAsentriaTempIn .1.11.3.5.2 +-- evHVACStatusAsentriaHumid .1.11.3.6 +-- evHVACStatusAsentriaHumidOut .1.11.3.6.1 +-- evHVACStatusAsentriaHumidIn .1.11.3.6.2 +-- evHVACStatusAirsys .1.11.4 +-- evHVACStatusAirsysAlarm .1.11.4.1 +-- evHVACStatusAirsysAlarmUnitTable .1.11.4.1.1 +-- evHVACStatusAirsysAlarmUnitEntry .1.11.4.1.1.1 +-- evHVACStatusAirsysAlarmUnitIndex .1.11.4.1.1.1.1 +-- evHVACStatusAirsysAlarmUnitLowPress .1.11.4.1.1.1.2 +-- evHVACStatusAirsysAlarmUnitHighPress .1.11.4.1.1.1.3 +-- evHVACStatusAirsysAlarmUnitEvapFan .1.11.4.1.1.1.4 +-- evHVACStatusAirsysAlarmUnitDirty .1.11.4.1.1.1.5 +-- evHVACStatusAirsysAlarmUnitDamper .1.11.4.1.1.1.6 +-- evHVACStatusAirsysAlarmUnitSupProbe .1.11.4.1.1.1.7 +-- evHVACStatusAirsysAlarmSmokeFire .1.11.4.1.2 +-- evHVACStatusAirsysAlarmLowRoomTemp .1.11.4.1.3 +-- evHVACStatusAirsysAlarmHighRoomTemp .1.11.4.1.4 +-- evHVACStatusAirsysAlarmPower .1.11.4.1.5 +-- evHVACStatusAirsysAlarmpLAN .1.11.4.1.6 +-- evHVACStatusAirsysAlarmClock .1.11.4.1.7 +-- evHVACStatusAirsysAlarmHumidProbe .1.11.4.1.8 +-- evHVACStatusAirsysAlarmOutProbe .1.11.4.1.9 +-- evHVACStatusAirsysAlarmBothCompress .1.11.4.1.10 +-- evHVACStatusAirsysAlarmGenerator .1.11.4.1.11 +-- evHVACStatusAirsysAlarmConnection .1.11.4.1.12 +-- evHVACStatusAirsysAlarmInProbe1 .1.11.4.1.13 +-- evHVACStatusAirsysAlarmInProbe2 .1.11.4.1.14 +-- evHVACStatusAirsysTempOut .1.11.4.2 +-- evHVACStatusAirsysTempIn .1.11.4.3 +-- evHVACStatusAirsysTempInBackup .1.11.4.4 +-- evHVACStatusAirsysHumidIn .1.11.4.5 +-- evHVACStatusAirsysUnitTable .1.11.4.6 +-- evHVACStatusAirsysUnitEntry .1.11.4.6.1 +-- evHVACStatusAirsysUnitIndex .1.11.4.6.1.1 +-- evHVACStatusAirsysUnitTempSupply .1.11.4.6.1.2 +-- evHVACStatusAirsysUnitFanspeed .1.11.4.6.1.3 +-- evHVACStatusAirsysUnitFreeOpening .1.11.4.6.1.4 +-- evHVACStatusAirsysUnitStatus .1.11.4.6.1.5 +-- evHVACStatusAirsysUnitLocked .1.11.4.6.1.6 +-- evHVACStatusAirsysUnitCompressor .1.11.4.6.1.7 +-- evHVACStatusAirsysUnitHeater .1.11.4.6.1.8 +-- evHVACStatusAirsysURuntimeSupplyFan .1.11.4.6.1.9 +-- evHVACStatusAirsysURuntimeCompressor .1.11.4.6.1.10 +-- evHVACStatusAirsysURuntimeHeat .1.11.4.6.1.11 +-- evHVACStatusAirsysURuntimeFreeCooling .1.11.4.6.1.12 +-- evHVACStatusAirsysUCountSupplyFan .1.11.4.6.1.13 +-- evHVACStatusAirsysUCountCompressor .1.11.4.6.1.14 +-- evHVACStatusAirsysUCountHeat .1.11.4.6.1.15 +-- evHVACStatusAirsysUCountFreeCooling .1.11.4.6.1.16 +-- evHVACStatusAirsysDay .1.11.4.7 +-- evHVACStatusAirsysDate .1.11.4.8 +-- evHVACStatusAirsysTime .1.11.4.9 +-- evHVACStatusAirsysVersion .1.11.4.10 +-- backupBattStatus .1.12 +-- liBattStatus .1.12.1 +-- liBattPercentCharge .1.12.1.1 +-- liBattRunning .1.12.1.2 +-- config .2 +-- eventSensorBasics .2.1 +-- esNumberEventSensors .2.1.1 +-- esTable .2.1.2 +-- esEntry .2.1.2.1 +-- esIndex .2.1.2.1.1 +-- esName .2.1.2.1.2 +-- esID .2.1.2.1.3 +-- esNumberTempSensors .2.1.2.1.4 +-- esTempReportingMode .2.1.2.1.5 +-- esNumberCCs .2.1.2.1.6 +-- esCCReportingMode .2.1.2.1.7 +-- esNumberHumidSensors .2.1.2.1.8 +-- esHumidReportingMode .2.1.2.1.9 +-- esNumberNoiseSensors .2.1.2.1.10 +-- esNoiseReportingMode .2.1.2.1.11 +-- esNumberAirflowSensors .2.1.2.1.12 +-- esAirflowReportingMode .2.1.2.1.13 +-- esNumberAnalog .2.1.2.1.14 +-- esAnalogReportingMode .2.1.2.1.15 +-- esNumberOutputs .2.1.2.1.16 +-- esOutputReportingMode .2.1.2.1.17 +-- esTempCombinedStatus .2.1.2.1.18 +-- esCCCombinedStatusBlock1 .2.1.2.1.19 +-- esCCCombinedStatusBlock2 .2.1.2.1.20 +-- esCCCombinedStatusBlock3 .2.1.2.1.21 +-- esCCCombinedStatusBlock4 .2.1.2.1.22 +-- esCCCombinedStatusBlock5 .2.1.2.1.23 +-- esCCCombinedStatusBlock6 .2.1.2.1.24 +-- esCCCombinedStatusBlock7 .2.1.2.1.25 +-- esCCCombinedStatusBlock8 .2.1.2.1.26 +-- esHumidCombinedStatus .2.1.2.1.27 +-- esAnalogCombinedStatusBlock1 .2.1.2.1.28 +-- esAnalogCombinedStatusBlock2 .2.1.2.1.29 +-- esAnalogCombinedStatusBlock3 .2.1.2.1.30 +-- esAnalogCombinedStatusBlock4 .2.1.2.1.31 +-- esAnalogCombinedStatusBlock5 .2.1.2.1.32 +-- esAnalogCombinedStatusBlock6 .2.1.2.1.33 +-- esOutputCombinedStatusBlock1 .2.1.2.1.34 +-- esOutputCombinedStatusBlock2 .2.1.2.1.35 +-- esNewSensors .2.1.3 +-- eventSensorPointConfig .2.2 +-- esPointConfigTempTable .2.2.1 +-- esPointConfigTempEntry .2.2.1.1 +-- espcTempIndexES .2.2.1.1.1 +-- espcTempIndexPoint .2.2.1.1.2 +-- espcTempEnable .2.2.1.1.3 +-- espcTempScale .2.2.1.1.4 +-- espcTempDeadband .2.2.1.1.5 +-- espcTempVHighTemp .2.2.1.1.6 +-- espcTempVHighActions .2.2.1.1.7 +-- espcTempVHighTrapnum .2.2.1.1.8 +-- espcTempVHighClass .2.2.1.1.9 +-- espcTempHighTemp .2.2.1.1.10 +-- espcTempHighActions .2.2.1.1.11 +-- espcTempHighTrapnum .2.2.1.1.12 +-- espcTempHighClass .2.2.1.1.13 +-- espcTempNormalActions .2.2.1.1.14 +-- espcTempNormalTrapnum .2.2.1.1.15 +-- espcTempNormalClass .2.2.1.1.16 +-- espcTempLowTemp .2.2.1.1.17 +-- espcTempLowActions .2.2.1.1.18 +-- espcTempLowTrapnum .2.2.1.1.19 +-- espcTempLowClass .2.2.1.1.20 +-- espcTempVLowTemp .2.2.1.1.21 +-- espcTempVLowActions .2.2.1.1.22 +-- espcTempVLowTrapnum .2.2.1.1.23 +-- espcTempVLowClass .2.2.1.1.24 +-- espcTempGroup .2.2.1.1.25 +-- esPointConfigCCTable .2.2.2 +-- esPointConfigCCEntry .2.2.2.1 +-- espcCCIndexES .2.2.2.1.1 +-- espcCCIndexPoint .2.2.2.1.2 +-- espcCCEnable .2.2.2.1.3 +-- espcCCName .2.2.2.1.4 +-- espcCCEventState .2.2.2.1.5 +-- espcCCThreshold .2.2.2.1.6 +-- espcCCEventActions .2.2.2.1.7 +-- espcCCEventTrapnum .2.2.2.1.8 +-- espcCCEventClass .2.2.2.1.9 +-- espcCCNormalActions .2.2.2.1.10 +-- espcCCNormalTrapnum .2.2.2.1.11 +-- espcCCNormalClass .2.2.2.1.12 +-- espcCCAlarmAlias .2.2.2.1.13 +-- espcCCNormalAlias .2.2.2.1.14 +-- espcCCNormalThreshold .2.2.2.1.15 +-- espcCCOverrideGlobalReminder .2.2.2.1.16 +-- espcCCReminderInterval .2.2.2.1.17 +-- espcCCGroup .2.2.2.1.18 +-- esPointConfigHumidTable .2.2.3 +-- esPointConfigHumidEntry .2.2.3.1 +-- espcHumidIndexES .2.2.3.1.1 +-- espcHumidIndexPoint .2.2.3.1.2 +-- espcHumidEnable .2.2.3.1.3 +-- espcHumidDeadband .2.2.3.1.4 +-- espcHumidVHighHumid .2.2.3.1.5 +-- espcHumidVHighActions .2.2.3.1.6 +-- espcHumidVHighTrapnum .2.2.3.1.7 +-- espcHumidVHighClass .2.2.3.1.8 +-- espcHumidHighHumid .2.2.3.1.9 +-- espcHumidHighActions .2.2.3.1.10 +-- espcHumidHighTrapnum .2.2.3.1.11 +-- espcHumidHighClass .2.2.3.1.12 +-- espcHumidNormalActions .2.2.3.1.13 +-- espcHumidNormalTrapnum .2.2.3.1.14 +-- espcHumidNormalClass .2.2.3.1.15 +-- espcHumidLowHumid .2.2.3.1.16 +-- espcHumidLowActions .2.2.3.1.17 +-- espcHumidLowTrapnum .2.2.3.1.18 +-- espcHumidLowClass .2.2.3.1.19 +-- espcHumidVLowHumid .2.2.3.1.20 +-- espcHumidVLowActions .2.2.3.1.21 +-- espcHumidVLowTrapnum .2.2.3.1.22 +-- espcHumidVLowClass .2.2.3.1.23 +-- espcHumidGroup .2.2.3.1.24 +-- esPointConfigAITable .2.2.5 +-- esPointConfigAIEntry .2.2.5.1 +-- espcAIIndexES .2.2.5.1.1 +-- espcAIIndexPoint .2.2.5.1.2 +-- espcAIEnable .2.2.5.1.3 +-- espcAIDeadband .2.2.5.1.5 +-- espcAIVhighValue .2.2.5.1.6 +-- espcAIVhighActions .2.2.5.1.7 +-- espcAIVhighTrapnum .2.2.5.1.8 +-- espcAIVhighClass .2.2.5.1.9 +-- espcAIHighValue .2.2.5.1.10 +-- espcAIHighActions .2.2.5.1.11 +-- espcAIHighTrapnum .2.2.5.1.12 +-- espcAIHighClass .2.2.5.1.13 +-- espcAINormalActions .2.2.5.1.14 +-- espcAINormalTrapnum .2.2.5.1.15 +-- espcAINormalClass .2.2.5.1.16 +-- espcAILowValue .2.2.5.1.17 +-- espcAILowActions .2.2.5.1.18 +-- espcAILowTrapnum .2.2.5.1.19 +-- espcAILowClass .2.2.5.1.20 +-- espcAIVlowValue .2.2.5.1.21 +-- espcAIVlowActions .2.2.5.1.22 +-- espcAIVlowTrapnum .2.2.5.1.23 +-- espcAIVlowClass .2.2.5.1.24 +-- espcAIConvUnitName .2.2.5.1.25 +-- espcAIConvHighValue .2.2.5.1.26 +-- espcAIConvHighUnit .2.2.5.1.27 +-- espcAIConvLowValue .2.2.5.1.29 +-- espcAIConvLowUnit .2.2.5.1.30 +-- espcAIDisplayFormat .2.2.5.1.32 +-- espcAIGroup .2.2.5.1.33 +-- esPointConfigOutputTable .2.2.6 +-- esPointConfigOutputEntry .2.2.6.1 +-- espcOutputIndexES .2.2.6.1.1 +-- espcOutputIndexPoint .2.2.6.1.2 +-- espcOutputEnable .2.2.6.1.3 +-- espcOutputActiveState .2.2.6.1.4 +-- espcOutputType .2.2.6.1.5 +-- espcOutputAliasValue .2.2.6.1.6 +-- espcOutputAliasColor .2.2.6.1.7 +-- espcOutputActiveAlias .2.2.6.1.10 +-- espcOutputActiveColor .2.2.6.1.11 +-- espcOutputActiveActions .2.2.6.1.12 +-- espcOutputActiveTrapnum .2.2.6.1.13 +-- espcOutputActiveClass .2.2.6.1.14 +-- espcOutputInactiveAlias .2.2.6.1.20 +-- espcOutputInactiveColor .2.2.6.1.21 +-- espcOutputInactiveActions .2.2.6.1.22 +-- espcOutputInactiveTrapnum .2.2.6.1.23 +-- espcOutputInactiveClass .2.2.6.1.24 +-- espcOutputGroup .2.2.6.1.25 +-- serialPorts .2.3 +-- numberPorts .2.3.1 +-- portConfigTable .2.3.2 +-- portConfigEntry .2.3.2.1 +-- portConfigIndex .2.3.2.1.1 +-- portConfigBaud .2.3.2.1.2 +-- portConfigDataFormat .2.3.2.1.3 +-- portConfigStripPtOutputLfs .2.3.2.1.4 +-- portConfigStripPtInputLfs .2.3.2.1.5 +-- portConfigMaskEnable .2.3.2.1.7 +-- portConfigDAEnable .2.3.2.1.8 +-- portConfigStoreAlarmsDPT .2.3.2.1.9 +-- portConfigRecordTimeout .2.3.2.1.10 +-- portConfigDataType .2.3.2.1.11 +-- portConfigEtxToCRLF .2.3.2.1.12 +-- portConfigMLREnable .2.3.2.1.13 +-- portConfigMLRStartField1Pos .2.3.2.1.14 +-- portConfigMLRStartField1Text .2.3.2.1.15 +-- portConfigMLRStartField2Pos .2.3.2.1.16 +-- portConfigMLRStartField2Text .2.3.2.1.17 +-- portConfigMLRNumLinesBefore .2.3.2.1.18 +-- portConfigMLREndDetection .2.3.2.1.19 +-- portConfigMLRLineCount .2.3.2.1.20 +-- portConfigMLREndField1Pos .2.3.2.1.21 +-- portConfigMLREndField1Text .2.3.2.1.22 +-- portConfigMLREndField2Pos .2.3.2.1.23 +-- portConfigMLREndField2Text .2.3.2.1.24 +-- portConfigMLRUseComplexRules .2.3.2.1.25 +-- portConfigBufferPT .2.3.2.1.26 +-- portConfigId .2.3.2.1.27 +-- portConfigMode .2.3.2.1.28 +-- portConfigHsk .2.3.2.1.29 +-- network .2.4 +-- interface .2.4.1 +-- ethernet .2.4.1.1 +-- ethernet1 .2.4.1.1.1 +-- eth1Mode .2.4.1.1.1.1 +-- eth1Address .2.4.1.1.1.2 +-- eth1SubnetMask .2.4.1.1.1.3 +-- eth1Router .2.4.1.1.1.4 +-- eth1VLAN .2.4.1.1.1.5 +-- eth1VLAN1 .2.4.1.1.1.5.1 +-- eth1VLAN1ID .2.4.1.1.1.5.1.1 +-- eth1VLAN1Priority .2.4.1.1.1.5.1.2 +-- eth1VLAN1Address .2.4.1.1.1.5.1.3 +-- eth1VLAN1SubnetMask .2.4.1.1.1.5.1.4 +-- eth1VLAN1Router .2.4.1.1.1.5.1.5 +-- eth1VLAN2 .2.4.1.1.1.5.2 +-- eth1VLAN2ID .2.4.1.1.1.5.2.1 +-- eth1VLAN2Priority .2.4.1.1.1.5.2.2 +-- eth1VLAN2Address .2.4.1.1.1.5.2.3 +-- eth1VLAN2SubnetMask .2.4.1.1.1.5.2.4 +-- eth1VLAN2Router .2.4.1.1.1.5.2.5 +-- eth1VLAN3 .2.4.1.1.1.5.3 +-- eth1VLAN3ID .2.4.1.1.1.5.3.1 +-- eth1VLAN3Priority .2.4.1.1.1.5.3.2 +-- eth1VLAN3Address .2.4.1.1.1.5.3.3 +-- eth1VLAN3SubnetMask .2.4.1.1.1.5.3.4 +-- eth1VLAN3Router .2.4.1.1.1.5.3.5 +-- eth1VLAN4 .2.4.1.1.1.5.4 +-- eth1VLAN4ID .2.4.1.1.1.5.4.1 +-- eth1VLAN4Priority .2.4.1.1.1.5.4.2 +-- eth1VLAN4Address .2.4.1.1.1.5.4.3 +-- eth1VLAN4SubnetMask .2.4.1.1.1.5.4.4 +-- eth1VLAN4Router .2.4.1.1.1.5.4.5 +-- eth1VLAN5 .2.4.1.1.1.5.5 +-- eth1VLAN5ID .2.4.1.1.1.5.5.1 +-- eth1VLAN5Priority .2.4.1.1.1.5.5.2 +-- eth1VLAN5Address .2.4.1.1.1.5.5.3 +-- eth1VLAN5SubnetMask .2.4.1.1.1.5.5.4 +-- eth1VLAN5Router .2.4.1.1.1.5.5.5 +-- eth1VLAN6 .2.4.1.1.1.5.6 +-- eth1VLAN6ID .2.4.1.1.1.5.6.1 +-- eth1VLAN6Priority .2.4.1.1.1.5.6.2 +-- eth1VLAN6Address .2.4.1.1.1.5.6.3 +-- eth1VLAN6SubnetMask .2.4.1.1.1.5.6.4 +-- eth1VLAN6Router .2.4.1.1.1.5.6.5 +-- eth1MAC .2.4.1.1.1.6 +-- eth1IPv6 .2.4.1.1.1.7 +-- eth1IPv6Mode .2.4.1.1.1.7.1 +-- eth1IPv6Static .2.4.1.1.1.7.2 +-- eth1IPv6StaticAddress .2.4.1.1.1.7.2.1 +-- eth1IPv6StaticRouter .2.4.1.1.1.7.2.2 +-- eth1IPv6Auto .2.4.1.1.1.7.3 +-- eth1IPv6AutoAddress1 .2.4.1.1.1.7.3.1 +-- eth1IPv6AutoAddress2 .2.4.1.1.1.7.3.2 +-- eth1IPv6AutoAddress3 .2.4.1.1.1.7.3.3 +-- eth1IPv6AutoAddress4 .2.4.1.1.1.7.3.4 +-- eth1IPv6LinkLocalAddress .2.4.1.1.1.7.4 +-- ethernet2 .2.4.1.1.2 +-- eth2Mode .2.4.1.1.2.1 +-- eth2Address .2.4.1.1.2.2 +-- eth2SubnetMask .2.4.1.1.2.3 +-- eth2Router .2.4.1.1.2.4 +-- eth2VLAN .2.4.1.1.2.5 +-- eth2VLAN1 .2.4.1.1.2.5.1 +-- eth2VLAN1ID .2.4.1.1.2.5.1.1 +-- eth2VLAN1Priority .2.4.1.1.2.5.1.2 +-- eth2VLAN1Address .2.4.1.1.2.5.1.3 +-- eth2VLAN1SubnetMask .2.4.1.1.2.5.1.4 +-- eth2VLAN1Router .2.4.1.1.2.5.1.5 +-- eth2VLAN2 .2.4.1.1.2.5.2 +-- eth2VLAN2ID .2.4.1.1.2.5.2.1 +-- eth2VLAN2Priority .2.4.1.1.2.5.2.2 +-- eth2VLAN2Address .2.4.1.1.2.5.2.3 +-- eth2VLAN2SubnetMask .2.4.1.1.2.5.2.4 +-- eth2VLAN2Router .2.4.1.1.2.5.2.5 +-- eth2VLAN3 .2.4.1.1.2.5.3 +-- eth2VLAN3ID .2.4.1.1.2.5.3.1 +-- eth2VLAN3Priority .2.4.1.1.2.5.3.2 +-- eth2VLAN3Address .2.4.1.1.2.5.3.3 +-- eth2VLAN3SubnetMask .2.4.1.1.2.5.3.4 +-- eth2VLAN3Router .2.4.1.1.2.5.3.5 +-- eth2VLAN4 .2.4.1.1.2.5.4 +-- eth2VLAN4ID .2.4.1.1.2.5.4.1 +-- eth2VLAN4Priority .2.4.1.1.2.5.4.2 +-- eth2VLAN4Address .2.4.1.1.2.5.4.3 +-- eth2VLAN4SubnetMask .2.4.1.1.2.5.4.4 +-- eth2VLAN4Router .2.4.1.1.2.5.4.5 +-- eth2VLAN5 .2.4.1.1.2.5.5 +-- eth2VLAN5ID .2.4.1.1.2.5.5.1 +-- eth2VLAN5Priority .2.4.1.1.2.5.5.2 +-- eth2VLAN5Address .2.4.1.1.2.5.5.3 +-- eth2VLAN5SubnetMask .2.4.1.1.2.5.5.4 +-- eth2VLAN5Router .2.4.1.1.2.5.5.5 +-- eth2VLAN6 .2.4.1.1.2.5.6 +-- eth2VLAN6ID .2.4.1.1.2.5.6.1 +-- eth2VLAN6Priority .2.4.1.1.2.5.6.2 +-- eth2VLAN6Address .2.4.1.1.2.5.6.3 +-- eth2VLAN6SubnetMask .2.4.1.1.2.5.6.4 +-- eth2VLAN6Router .2.4.1.1.2.5.6.5 +-- eth2MAC .2.4.1.1.2.6 +-- eth2IPv6 .2.4.1.1.2.7 +-- eth2IPv6Mode .2.4.1.1.2.7.1 +-- eth2IPv6Static .2.4.1.1.2.7.2 +-- eth2IPv6StaticAddress .2.4.1.1.2.7.2.1 +-- eth2IPv6StaticRouter .2.4.1.1.2.7.2.2 +-- eth2IPv6Auto .2.4.1.1.2.7.3 +-- eth2IPv6AutoAddress1 .2.4.1.1.2.7.3.1 +-- eth2IPv6AutoAddress2 .2.4.1.1.2.7.3.2 +-- eth2IPv6AutoAddress3 .2.4.1.1.2.7.3.3 +-- eth2IPv6AutoAddress4 .2.4.1.1.2.7.3.4 +-- eth2IPv6LinkLocalAddress .2.4.1.1.2.7.4 +-- defaultRouter .2.4.2 +-- dnsTable .2.4.3 +-- dnsEntry .2.4.3.1 +-- dnsIndex .2.4.3.1.1 +-- dnsAddress .2.4.3.1.2 +-- hostname .2.4.4 +-- hostTable .2.4.5 +-- hostEntry .2.4.5.1 +-- hostIndex .2.4.5.1.1 +-- hostDeclaration .2.4.5.1.2 +-- ncpDuplex .2.4.6 +-- ncpTimeout .2.4.7 +-- snmp .2.4.8 +-- snmpAgentEnable .2.4.8.1 +-- snmpNotificationCaptureEnable .2.4.8.5 +-- snmpNotificationCaptureFile .2.4.8.6 +-- snmpNotificationTx .2.4.8.7 +-- snmpNtfnAttempts .2.4.8.7.1 +-- snmpNtfnTimeout .2.4.8.7.2 +-- snmpNtfnCycles .2.4.8.7.3 +-- snmpNtfnSnooze .2.4.8.7.4 +-- snmpProxy .2.4.8.8 +-- snmpProxyTable .2.4.8.8.1 +-- snmpProxyEntry .2.4.8.8.1.1 +-- snmpProxyIndex .2.4.8.8.1.1.1 +-- snmpProxyEgressOIDBranch .2.4.8.8.1.1.2 +-- snmpProxyIP .2.4.8.8.1.1.3 +-- snmpProxyPort .2.4.8.8.1.1.4 +-- snmpProxyIngressOIDBranch .2.4.8.8.1.1.5 +-- snmpProxyName .2.4.8.8.1.1.6 +-- snmpPoll .2.4.8.9 +-- snmpPMode .2.4.8.9.1 +-- snmpPBufferFile .2.4.8.9.2 +-- snmpPBufferAllPeriod .2.4.8.9.3 +-- snmpPRequestTable .2.4.8.9.4 +-- snmpPRequestEntry .2.4.8.9.4.1 +-- snmpPRequestIndex .2.4.8.9.4.1.1 +-- snmpPRequestDescription .2.4.8.9.4.1.2 +-- snmpPRequestAgent .2.4.8.9.4.1.3 +-- snmpPRequestReadcom .2.4.8.9.4.1.4 +-- snmpPRequestOID .2.4.8.9.4.1.5 +-- snmpPRequestPeriod .2.4.8.9.4.1.6 +-- snmpPRequestID .2.4.8.9.4.1.7 +-- snmpPRequestThreshold .2.4.8.9.4.1.8 +-- snmpPRequestResultStatus .2.4.8.9.4.1.10 +-- snmpPRequestResultValue .2.4.8.9.4.1.11 +-- snmpPRequestResultTime .2.4.8.9.4.1.12 +-- snmpPRequestResultType .2.4.8.9.4.1.13 +-- ftpPush .2.4.9 +-- ftpPushEnable .2.4.9.1 +-- ftpPushServer .2.4.9.2 +-- ftpPushAccount .2.4.9.5 +-- ftpPushDirectory .2.4.9.6 +-- ftpPushperiod .2.4.9.7 +-- ftpPushPushFileTable .2.4.9.8 +-- ftpPushPushFileEntry .2.4.9.8.1 +-- ftpPushPushFileIndex .2.4.9.8.1.1 +-- ftpPushPushFile .2.4.9.8.1.2 +-- ftpPushPushAudit .2.4.9.9 +-- ftpPushPushAlarms .2.4.9.10 +-- ftpPushRemoteFileTable .2.4.9.11 +-- ftpPushRemoteFileEntry .2.4.9.11.1 +-- ftpPushRemoteFileIndex .2.4.9.11.1.1 +-- ftpPushRemoteFileName .2.4.9.11.1.2 +-- ftpPushRemoteAlarmName .2.4.9.12 +-- ftpPushPassive .2.4.9.13 +-- ftpPushIncludeDate .2.4.9.14 +-- ftpPushIncludeTime .2.4.9.15 +-- ftpPushIncludeSeq .2.4.9.16 +-- ftpPushPermissions .2.4.9.17 +-- ppp .2.4.10 +-- pppDial .2.4.10.1 +-- pppDialEnable .2.4.10.1.1 +-- pppDialNumber .2.4.10.1.2 +-- pppDialIdleTimeout .2.4.10.1.5 +-- pppDialRetries .2.4.10.1.6 +-- pppDialCDTimeout .2.4.10.1.7 +-- pppDialLoginTimeout .2.4.10.1.8 +-- pppDialMdmInit .2.4.10.1.9 +-- pppDialSuggestIP .2.4.10.1.10 +-- pppDialPlainLogin .2.4.10.1.11 +-- pppHost .2.4.10.2 +-- pppHostEnable .2.4.10.2.1 +-- pppHostIdleTimeout .2.4.10.2.2 +-- pppHostLocalIP .2.4.10.2.3 +-- pppHostRemoteIP .2.4.10.2.4 +-- routing .2.4.11 +-- pppRoutingEnable .2.4.11.1 +-- ethRoutingEnable .2.4.11.2 +-- ethRoutingNATEnable .2.4.11.3 +-- routingInterface .2.4.11.4 +-- eth2WanRoutingEnable .2.4.11.5 +-- netSecurity .2.4.12 +-- ipRestriction .2.4.12.1 +-- ipRestrictionTable .2.4.12.1.1 +-- ipRestrictionEntry .2.4.12.1.1.1 +-- ipRestrictionIndex .2.4.12.1.1.1.1 +-- ipRestrictionEnable .2.4.12.1.1.1.2 +-- ipRestrictionMask .2.4.12.1.1.1.3 +-- rts .2.4.13 +-- rtsFileTable .2.4.13.1 +-- rtsFileEntry .2.4.13.1.1 +-- rtsFileIndex .2.4.13.1.1.1 +-- rtsFileMode .2.4.13.1.1.2 +-- rtsFileShowAnswer .2.4.13.1.1.3 +-- rtsFileReqXON .2.4.13.1.1.4 +-- rtsFileTimeout .2.4.13.1.1.5 +-- rtsFileEmptyClose .2.4.13.1.1.6 +-- rtsFilePushHost .2.4.13.1.1.7 +-- rtsFilePushPort .2.4.13.1.1.8 +-- rtsFilePushRetryTimer .2.4.13.1.1.9 +-- rtsAlarms .2.4.13.2 +-- rtsAlarmsMode .2.4.13.2.1 +-- rtsAlarmsShowAnswer .2.4.13.2.2 +-- rtsAlarmsReqXON .2.4.13.2.3 +-- rtsAlarmsTimeout .2.4.13.2.4 +-- rtsAlarmsEmptyClose .2.4.13.2.5 +-- rtsAlarmsPushHost .2.4.13.2.6 +-- rtsAlarmsPushPort .2.4.13.2.7 +-- rtsAlarmsPushRetryTimer .2.4.13.2.8 +-- trap .2.4.14 +-- trapInclude .2.4.14.1 +-- trapIncludeDateTime .2.4.14.1.1 +-- trapIncludeSiteName .2.4.14.1.2 +-- trapIncludeSensorID .2.4.14.1.3 +-- trapIncludeUDName .2.4.14.1.4 +-- trapIncludeUDState .2.4.14.1.5 +-- trapIncludeSourceAddress .2.4.14.1.6 +-- trapAuthFailEnable .2.4.14.2 +-- routeTest .2.4.15 +-- routeTestEnable .2.4.15.1 +-- routeTestPeriod .2.4.15.2 +-- routeTestAddressTable .2.4.15.3 +-- routeTestAddressEntry .2.4.15.3.1 +-- routeTestAddressIndex .2.4.15.3.1.1 +-- routeTestAddress .2.4.15.3.1.2 +-- wireless .2.4.16 +-- wirelessMode .2.4.16.1 +-- wirelessAPN .2.4.16.2 +-- wirelessIdleTimeout .2.4.16.3 +-- wirelessDRE .2.4.16.9 +-- wirelessPPPUsername .2.4.16.10 +-- wirelessFirewall .2.4.16.11 +-- wirelessKeepaliveThreshold .2.4.16.12 +-- wirelessPPPDebug .2.4.16.13 +-- wirelessConnectivity .2.4.16.20 +-- wirelessConnEnable .2.4.16.20.1 +-- wirelessConnCheckInterval .2.4.16.20.2 +-- wirelessConnFailThreshold .2.4.16.20.3 +-- wirelessConnIP1 .2.4.16.20.10 +-- wirelessConnIP2 .2.4.16.20.11 +-- email .2.4.17 +-- emailServer .2.4.17.1 +-- emailDomain .2.4.17.2 +-- emailAuthEnable .2.4.17.3 +-- netAdvanced .2.4.18 +-- arpFilter .2.4.18.1 +-- web .2.4.19 +-- webEnable .2.4.19.1 +-- webPort .2.4.19.2 +-- webTimeout .2.4.19.3 +-- webXMLProxy .2.4.19.4 +-- wxpEnable .2.4.19.4.1 +-- wxpDeviceTable .2.4.19.4.2 +-- wxpDeviceEntry .2.4.19.4.2.1 +-- wxpDeviceIndex .2.4.19.4.2.1.1 +-- wxpDeviceEnable .2.4.19.4.2.1.2 +-- wxpDeviceIPAddress .2.4.19.4.2.1.3 +-- wxpDevicePort .2.4.19.4.2.1.4 +-- wxpDeviceRemoteFile .2.4.19.4.2.1.5 +-- wxpDeviceLocalFile .2.4.19.4.2.1.6 +-- wxpDeviceTimeout .2.4.19.4.2.1.7 +-- wxpDeviceTimestamp .2.4.19.4.2.1.8 +-- ethExpan .2.4.20 +-- ethExpanIp .2.4.20.1 +-- ethExpanMask .2.4.20.2 +-- ethExpanCardTable .2.4.20.3 +-- ethExpanCardEntry .2.4.20.3.1 +-- ethExpanCardIndex .2.4.20.3.1.1 +-- ethExpanCardMAC .2.4.20.3.1.2 +-- ethExpanDHCP .2.4.20.6 +-- ethExpanDHCPStartIp .2.4.20.6.1 +-- ethExpanDHCPLeaseTime .2.4.20.6.2 +-- ipv6 .2.4.21 +-- ipv6DefaultRouter .2.4.21.1 +-- cpe .2.4.22 +-- cpeTable .2.4.22.1 +-- cpeEntry .2.4.22.1.1 +-- cpeIndex .2.4.22.1.1.1 +-- cpeHost .2.4.22.1.1.2 +-- cpeName .2.4.22.1.1.3 +-- cpeDescription .2.4.22.1.1.4 +-- cpeKeepalive .2.4.22.1.1.5 +-- cpeThreshold .2.4.22.1.1.6 +-- cpeEventReminderInterval .2.4.22.1.1.7 +-- cpeKeepaliveTicks .2.4.22.1.1.20 +-- cpePingSize .2.4.22.1.1.21 +-- cpeInfoReset .2.4.22.1.1.30 +-- cpeInfoNumReq .2.4.22.1.1.31 +-- cpeInfoNumGoodResp .2.4.22.1.1.32 +-- cpeInfoNumBadResp .2.4.22.1.1.33 +-- cpeInfoNumLostResp .2.4.22.1.1.34 +-- cpeInfoPercentLoss .2.4.22.1.1.35 +-- cpeInfoPercentBad .2.4.22.1.1.36 +-- dnp3 .2.4.23 +-- dnp3General .2.4.23.1 +-- dnp3Mode .2.4.23.1.1 +-- dnp3SelfAddressEnable .2.4.23.1.2 +-- dnp3KeepaliveTimeout .2.4.23.1.3 +-- dnp3MaxRXFragmentSize .2.4.23.1.4 +-- dnp3MaxTXFragmentSize .2.4.23.1.5 +-- dnp3UnsolResponseEnable .2.4.23.1.6 +-- dnp3UnsolResponseTimeout .2.4.23.1.7 +-- dnp3UnsolResponseRetries .2.4.23.1.8 +-- dnp3LogFilter .2.4.23.1.9 +-- dnp3Outstation .2.4.23.2 +-- dnp3OutstationTCPPort .2.4.23.2.1 +-- dnp3OutstationDNP3Address .2.4.23.2.2 +-- dnp3OutstationMasterIPAddress .2.4.23.2.3 +-- dnp3OutstationMasterDNP3Address .2.4.23.2.4 +-- dnp3OutstationUnsolResponseDNP3Address .2.4.23.2.5 +-- dnp3Master .2.4.23.3 +-- dnp3Error .2.4.23.4 +-- dnp3DuplicateFragmentCount .2.4.23.4.1 +-- dnp3CollidingFragmentCount .2.4.23.4.2 +-- dnp3UnsolResponseCfmFailCount .2.4.23.4.3 +-- dnp3SolCfmFailCount .2.4.23.4.4 +-- dnp3ObjParseErrorCount .2.4.23.4.5 +-- dnp3FrameParseErrorCount .2.4.23.4.6 +-- dnp3DiscardedFrameCount .2.4.23.4.7 +-- dnp3BadBlockCount .2.4.23.4.8 +-- dnp3UnsolResponseRetryCount .2.4.23.4.9 +-- dnp3UnsupportedFrameCount .2.4.23.4.10 +-- dnp3Status .2.4.23.5 +-- dnp3OutstationCount .2.4.23.5.1 +-- dnp3ConnPeer .2.4.23.5.2 +-- dnp3StartTime .2.4.23.5.3 +-- dnp3EventAwaitingSolCfmCount .2.4.23.5.4 +-- dnp3EventAwaitingUnsolCfmCount .2.4.23.5.5 +-- dnp3EventCount .2.4.23.5.6 +-- dnp3EventClass1Count .2.4.23.5.7 +-- dnp3EventClass2Count .2.4.23.5.8 +-- dnp3EventClass3Count .2.4.23.5.9 +-- dnp3RxFragmentTime .2.4.23.5.10 +-- dnp3TxFragmentTime .2.4.23.5.11 +-- dnp3TxCachedResponseCount .2.4.23.5.12 +-- dnp3TxUnsolResponseCount .2.4.23.5.13 +-- dnp3TxSolResponseCount .2.4.23.5.14 +-- dnp3TxFragmentReqCfmCount .2.4.23.5.15 +-- dnp3RxUnsolResponseCfmCount .2.4.23.5.16 +-- dnp3RxSolResponseCfmCount .2.4.23.5.17 +-- dnp3RxFunctionCount .2.4.23.5.18 +-- dnp3RxReadFunctionCount .2.4.23.5.19 +-- dnp3RxWriteFunctionCount .2.4.23.5.20 +-- dnp3RxDirOpFunctionCount .2.4.23.5.21 +-- dnp3RxEnableURCount .2.4.23.5.22 +-- dnp3RxDisableURCount .2.4.23.5.23 +-- dnp3RxSolObjectCount .2.4.23.5.40 +-- dnp3TxSolObjectCount .2.4.23.5.41 +-- dnp3RxFrameTime .2.4.23.5.42 +-- dnp3TxFrameTime .2.4.23.5.43 +-- dnp3TxFrameCount .2.4.23.5.44 +-- dnp3RxAcceptedFrameCount .2.4.23.5.45 +-- dnp3RxSupportedFrameCount .2.4.23.5.46 +-- modem .2.5 +-- modemFormat .2.5.1 +-- modemInitString .2.5.2 +-- modemCallAttempts .2.5.4 +-- modemCallDelay .2.5.5 +-- modemCmdTimout .2.5.6 +-- modemGoto .2.5.7 +-- modemClid .2.5.8 +-- modemCLIDEnable .2.5.8.1 +-- modemCLIDNumberTable .2.5.8.2 +-- modemCLIDNumberEntry .2.5.8.2.1 +-- modemCLIDNumberIndex .2.5.8.2.1.1 +-- modemCLIDNumber .2.5.8.2.1.2 +-- modemTAPInitString .2.5.9 +-- modemTAP8N1 .2.5.10 +-- time .2.8 +-- clock .2.8.1 +-- console .2.10 +-- consoleDuplex .2.10.1 +-- consoleTimeout .2.10.2 +-- consoleConfirm .2.10.7 +-- unitSecurity .2.11 +-- secCore .2.11.1 +-- scShowPasswordPrompt .2.11.1.1 +-- scConsoleLoginRequired .2.11.1.2 +-- scModemLoginRequired .2.11.1.3 +-- scTelnetLoginRequired .2.11.1.4 +-- scTelnetPTLoginRequired .2.11.1.5 +-- scRTSLoginRequired .2.11.1.6 +-- scAuthMode .2.11.1.7 +-- scRightsGroup .2.11.1.8 +-- secUserTable .2.11.2 +-- secUserEntry .2.11.2.1 +-- secUserIndex .2.11.2.1.1 +-- secUserEnable .2.11.2.1.2 +-- secUserConnectVia .2.11.2.1.5 +-- secUserLoginTo .2.11.2.1.6 +-- secUserAccessFile .2.11.2.1.7 +-- secUserPTEscapeTo .2.11.2.1.9 +-- secUserPPPType .2.11.2.1.10 +-- secUserRights .2.11.2.1.11 +-- secUserEventsReadAccess .2.11.2.1.13 +-- secUserAuditReadAccess .2.11.2.1.14 +-- secUserEventsWriteAccess .2.11.2.1.16 +-- secUserAuditWriteAccess .2.11.2.1.17 +-- secUserExpiration .2.11.2.1.18 +-- secUserCallbackNumber1 .2.11.2.1.19 +-- secUserCallbackNumber2 .2.11.2.1.20 +-- secUserCallbackNumber3 .2.11.2.1.21 +-- secUserChallengeTelnetMode .2.11.2.1.22 +-- secUserChallengeModemMode .2.11.2.1.23 +-- secUserChallengeConsoleMode .2.11.2.1.24 +-- secUserChallengeTelnetSendTo .2.11.2.1.25 +-- secUserChallengeModemSendTo .2.11.2.1.26 +-- secUserChallengeExpiration .2.11.2.1.27 +-- secFactory .2.11.3 +-- sfEnable .2.11.3.1 +-- sfSecret .2.11.3.2 +-- secSSH .2.11.4 +-- secVPN .2.11.5 +-- event .2.12 +-- evCore .2.12.1 +-- evClassNameTable .2.12.1.1 +-- evClassNameEntry .2.12.1.1.1 +-- evClassNameIndex .2.12.1.1.1.1 +-- evClassName .2.12.1.1.1.2 +-- evReminderInterval .2.12.1.2 +-- evLog .2.12.1.3 +-- evLogEnable .2.12.1.3.1 +-- evLogStoreAlarm .2.12.1.3.2 +-- evLogMaxSize .2.12.1.3.3 +-- evLogStoreSensor .2.12.1.3.4 +-- evLogTimeStampAlarms .2.12.1.3.5 +-- evLogPrependName .2.12.1.3.6 +-- evMgmt .2.12.1.4 +-- evMgmtReprocess .2.12.1.4.3 +-- evData .2.12.2 +-- evdCore .2.12.2.1 +-- evdExitOnTrue .2.12.2.1.1 +-- evdFilterAction .2.12.2.1.2 +-- evdWildCardChar .2.12.2.1.3 +-- evdTable .2.12.2.2 +-- evdEntry .2.12.2.2.1 +-- evdIndex .2.12.2.2.1.1 +-- evdEnable .2.12.2.2.1.2 +-- evdName .2.12.2.2.1.3 +-- evdEquation .2.12.2.2.1.4 +-- evdThreshold .2.12.2.2.1.5 +-- evdAutoclear .2.12.2.2.1.6 +-- evdClearInterval .2.12.2.2.1.7 +-- evdClearTime .2.12.2.2.1.8 +-- evdActions .2.12.2.2.1.9 +-- evdClass .2.12.2.2.1.10 +-- evdTrapNum .2.12.2.2.1.11 +-- evdMode .2.12.2.2.1.12 +-- evdFieldTable .2.12.2.3 +-- evdFieldEntry .2.12.2.3.1 +-- evdFieldIndex .2.12.2.3.1.1 +-- evdFieldStart .2.12.2.3.1.2 +-- evdFieldLength .2.12.2.3.1.3 +-- evdFieldName .2.12.2.3.1.4 +-- evdFieldLine .2.12.2.3.1.5 +-- evdFieldType .2.12.2.3.1.6 +-- evdMacroTable .2.12.2.4 +-- evdMacroEntry .2.12.2.4.1 +-- evdMacroIndex .2.12.2.4.1.1 +-- evdMacroName .2.12.2.4.1.2 +-- evdMacroEquation .2.12.2.4.1.3 +-- evNoData1 .2.12.3 +-- evNoData1Enable .2.12.3.1 +-- evNoData1Actions .2.12.3.2 +-- evNoData1Message .2.12.3.3 +-- evNoData1TrapNum .2.12.3.4 +-- evNoData1Class .2.12.3.5 +-- evNoData1Sched1Begin .2.12.3.6 +-- evNoData1Sched1End .2.12.3.7 +-- evNoData1Sched1Duration .2.12.3.8 +-- evNoData1Sched2Begin .2.12.3.9 +-- evNoData1Sched2End .2.12.3.10 +-- evNoData1Sched2Duration .2.12.3.11 +-- evNoData1PortEnableTable .2.12.3.12 +-- evNoData1PortEnableEntry .2.12.3.12.1 +-- evNoData1PortEnableIndex .2.12.3.12.1.1 +-- evNoData1PortEnable .2.12.3.12.1.2 +-- evNoData1Exclusions .2.12.3.13 +-- evNoData1Days .2.12.3.14 +-- evNoData2 .2.12.4 +-- evNoData2Enable .2.12.4.1 +-- evNoData2Actions .2.12.4.2 +-- evNoData2Message .2.12.4.3 +-- evNoData2TrapNum .2.12.4.4 +-- evNoData2Class .2.12.4.5 +-- evNoData2Sched1Begin .2.12.4.6 +-- evNoData2Sched1End .2.12.4.7 +-- evNoData2Sched1Duration .2.12.4.8 +-- evNoData2Sched2Begin .2.12.4.9 +-- evNoData2Sched2End .2.12.4.10 +-- evNoData2Sched2Duration .2.12.4.11 +-- evNoData2PortEnableTable .2.12.4.12 +-- evNoData2PortEnableEntry .2.12.4.12.1 +-- evNoData2PortEnableIndex .2.12.4.12.1.1 +-- evNoData2PortEnable .2.12.4.12.1.2 +-- evNoData2Exclusions .2.12.4.13 +-- evNoData2Days .2.12.4.14 +-- evSched1 .2.12.5 +-- evSched1Enable .2.12.5.1 +-- evSched1Actions .2.12.5.2 +-- evSched1Message .2.12.5.3 +-- evSched1TrapNum .2.12.5.4 +-- evSched1Class .2.12.5.5 +-- evSched1Sunday .2.12.5.6 +-- evSched1Monday .2.12.5.7 +-- evSched1Tuesday .2.12.5.8 +-- evSched1Wednesday .2.12.5.9 +-- evSched1Thursday .2.12.5.10 +-- evSched1Friday .2.12.5.11 +-- evSched1Saturday .2.12.5.12 +-- evSched1Exclusions .2.12.5.13 +-- evSched2 .2.12.6 +-- evSched2Enable .2.12.6.1 +-- evSched2Actions .2.12.6.2 +-- evSched2Message .2.12.6.3 +-- evSched2TrapNum .2.12.6.4 +-- evSched2Class .2.12.6.5 +-- evSched2Sunday .2.12.6.6 +-- evSched2Monday .2.12.6.7 +-- evSched2Tuesday .2.12.6.8 +-- evSched2Wednesday .2.12.6.9 +-- evSched2Thursday .2.12.6.10 +-- evSched2Friday .2.12.6.11 +-- evSched2Saturday .2.12.6.12 +-- evSched2Exclusions .2.12.6.13 +-- evShskLowTable .2.12.7 +-- evShskLowEntry .2.12.7.1 +-- evShskLowIndex .2.12.7.1.1 +-- evShskLowEnable .2.12.7.1.2 +-- evShskLowActions .2.12.7.1.3 +-- evShskLowMessage .2.12.7.1.4 +-- evShskLowClass .2.12.7.1.5 +-- evShskLowTrapNum .2.12.7.1.6 +-- evShskHighTable .2.12.8 +-- evShskHighEntry .2.12.8.1 +-- evShskHighIndex .2.12.8.1.1 +-- evShskHighEnable .2.12.8.1.2 +-- evShskHighActions .2.12.8.1.3 +-- evShskHighMessage .2.12.8.1.4 +-- evShskHighClass .2.12.8.1.5 +-- evShskHighTrapNum .2.12.8.1.6 +-- evNoSensor .2.12.9 +-- evNoSensorTimeout .2.12.9.1 +-- evNoSensorActions .2.12.9.2 +-- evNoSensorTrapNum .2.12.9.3 +-- evNoSensorClass .2.12.9.4 +-- fuelSensor .2.12.11 +-- fuelSensorGeneralTable .2.12.11.1 +-- fsGenEntry .2.12.11.1.1 +-- fsGenIndex .2.12.11.1.1.1 +-- fsGenName .2.12.11.1.1.2 +-- fsGenSensorType .2.12.11.1.1.3 +-- fsGenDistanceUnit .2.12.11.1.1.4 +-- fsGenRawValueTop .2.12.11.1.1.5 +-- fsGenTopOffset .2.12.11.1.1.6 +-- fsGenRawValueBottom .2.12.11.1.1.7 +-- fsGenBottomOffset .2.12.11.1.1.8 +-- fsGenInputES .2.12.11.1.1.9 +-- fsGenInputPoint .2.12.11.1.1.10 +-- fsGenFilterAveraging .2.12.11.1.1.11 +-- fsGenSysrepEnable .2.12.11.1.1.12 +-- fsGenSysrepThreshold .2.12.11.1.1.13 +-- fsGenSysrepLimit .2.12.11.1.1.14 +-- fsGenSysrepPackage .2.12.11.1.1.15 +-- fsGenGroup .2.12.11.1.1.16 +-- fsGenEnable .2.12.11.1.1.17 +-- fsGenFuelType .2.12.11.1.1.18 +-- fuelSensorTankTable .2.12.11.2 +-- fsTankEntry .2.12.11.2.1 +-- fsTankIndex .2.12.11.2.1.1 +-- fsTankHeight .2.12.11.2.1.2 +-- fsTankDimA .2.12.11.2.1.3 +-- fsTankDimB .2.12.11.2.1.4 +-- fsTankVolume .2.12.11.2.1.5 +-- fsTankVolumeUnit .2.12.11.2.1.6 +-- fsTankShape .2.12.11.2.1.7 +-- fuelSensorCustomTankTable .2.12.11.3 +-- fsCustomTankEntry .2.12.11.3.1 +-- fsCustomTankIndexFS .2.12.11.3.1.1 +-- fsCustomTankIndexDatum .2.12.11.3.1.2 +-- fsCustomTankHeight .2.12.11.3.1.3 +-- fsCustomTankVolume .2.12.11.3.1.4 +-- fuelSensorVolumeTable .2.12.11.4 +-- fsVolumeEntry .2.12.11.4.1 +-- fsVolumeIndex .2.12.11.4.1.1 +-- fsVolumeEnable .2.12.11.4.1.2 +-- fsVolumeDeadband .2.12.11.4.1.3 +-- fsVolumeVHighValue .2.12.11.4.1.4 +-- fsVolumeVHighActions .2.12.11.4.1.5 +-- fsVolumeVHighTrapNum .2.12.11.4.1.6 +-- fsVolumeVHighClass .2.12.11.4.1.7 +-- fsVolumeHighValue .2.12.11.4.1.8 +-- fsVolumeHighActions .2.12.11.4.1.9 +-- fsVolumeHighTrapNum .2.12.11.4.1.10 +-- fsVolumeHighClass .2.12.11.4.1.11 +-- fsVolumeNormalActions .2.12.11.4.1.12 +-- fsVolumeNormalTrapNum .2.12.11.4.1.13 +-- fsVolumeNormalClass .2.12.11.4.1.14 +-- fsVolumeLowValue .2.12.11.4.1.15 +-- fsVolumeLowActions .2.12.11.4.1.16 +-- fsVolumeLowTrapNum .2.12.11.4.1.17 +-- fsVolumeLowClass .2.12.11.4.1.18 +-- fsVolumeVLowValue .2.12.11.4.1.19 +-- fsVolumeVLowActions .2.12.11.4.1.20 +-- fsVolumeVLowTrapNum .2.12.11.4.1.21 +-- fsVolumeVLowClass .2.12.11.4.1.22 +-- fuelSensorDisconnectTable .2.12.11.5 +-- fsDiscEntry .2.12.11.5.1 +-- fsDiscIndex .2.12.11.5.1.1 +-- fsDiscEnable .2.12.11.5.1.2 +-- fsDiscHighValue .2.12.11.5.1.3 +-- fsDiscLowValue .2.12.11.5.1.4 +-- fsDiscActions .2.12.11.5.1.5 +-- fsDiscTrapNum .2.12.11.5.1.6 +-- fsDiscClass .2.12.11.5.1.7 +-- fsDiscNormalActions .2.12.11.5.1.8 +-- fsDiscNormalTrapNum .2.12.11.5.1.9 +-- fsDiscNormalClass .2.12.11.5.1.10 +-- fuelSensorSuddenChangeTable .2.12.11.6 +-- fsSuddenChangeEntry .2.12.11.6.1 +-- fsSuddenChangeIndex .2.12.11.6.1.1 +-- fsSuddenChangeEnable .2.12.11.6.1.2 +-- fsSuddenChangeTime .2.12.11.6.1.3 +-- fsSuddenChangeAmplitude .2.12.11.6.1.4 +-- fsSuddenChangeActions .2.12.11.6.1.5 +-- fsSuddenChangeTrapNum .2.12.11.6.1.6 +-- fsSuddenChangeClass .2.12.11.6.1.7 +-- fuelSensorSlowChangeTable .2.12.11.7 +-- fuelSensorSlowChangeEntry .2.12.11.7.1 +-- fsSlowChangeIndex .2.12.11.7.1.1 +-- fsSlowChangeEnable .2.12.11.7.1.2 +-- fsSlowChangeTime .2.12.11.7.1.3 +-- fsSlowChangeAmplitude .2.12.11.7.1.4 +-- fsSlowChangeActions .2.12.11.7.1.5 +-- fsSlowChangeTrapNum .2.12.11.7.1.6 +-- fsSlowChangeClass .2.12.11.7.1.7 +-- acPowerMonitor .2.12.12 +-- acpmGeneralTable .2.12.12.1 +-- acpmGenEntry .2.12.12.1.1 +-- acpmGenIndex .2.12.12.1.1.1 +-- acpmGenDevice .2.12.12.1.1.2 +-- acpmGenName .2.12.12.1.1.3 +-- acpmGenAddress .2.12.12.1.1.4 +-- acpmGenPtRatio .2.12.12.1.1.5 +-- acpmGenCtRatio .2.12.12.1.1.6 +-- acpmGenPowerType .2.12.12.1.1.7 +-- acpmGenSysrepPackage .2.12.12.1.1.8 +-- acpmGenGroup .2.12.12.1.1.9 +-- acpmGenEnable .2.12.12.1.1.10 +-- acpmAvgVoltageTable .2.12.12.2 +-- acpmAvgVoltageEntry .2.12.12.2.1 +-- acpmAvgVoltageIndex .2.12.12.2.1.1 +-- acpmAvgVoltageEnable .2.12.12.2.1.2 +-- acpmAvgVoltageDeadband .2.12.12.2.1.3 +-- acpmAvgVoltageVHighValue .2.12.12.2.1.4 +-- acpmAvgVoltageVHighActions .2.12.12.2.1.5 +-- acpmAvgVoltageVHighTrapNum .2.12.12.2.1.6 +-- acpmAvgVoltageVHighClass .2.12.12.2.1.7 +-- acpmAvgVoltageHighValue .2.12.12.2.1.8 +-- acpmAvgVoltageHighActions .2.12.12.2.1.9 +-- acpmAvgVoltageHighTrapNum .2.12.12.2.1.10 +-- acpmAvgVoltageHighClass .2.12.12.2.1.11 +-- acpmAvgVoltageNormalActions .2.12.12.2.1.12 +-- acpmAvgVoltageNormalTrapNum .2.12.12.2.1.13 +-- acpmAvgVoltageNormalClass .2.12.12.2.1.14 +-- acpmAvgVoltageLowValue .2.12.12.2.1.15 +-- acpmAvgVoltageLowActions .2.12.12.2.1.16 +-- acpmAvgVoltageLowTrapNum .2.12.12.2.1.17 +-- acpmAvgVoltageLowClass .2.12.12.2.1.18 +-- acpmAvgVoltageVLowValue .2.12.12.2.1.19 +-- acpmAvgVoltageVLowActions .2.12.12.2.1.20 +-- acpmAvgVoltageVLowTrapNum .2.12.12.2.1.21 +-- acpmAvgVoltageVLowClass .2.12.12.2.1.22 +-- acpmAvgVoltageSysrepEnable .2.12.12.2.1.23 +-- acpmAvgVoltageSysrepThreshold .2.12.12.2.1.24 +-- acpmAvgVoltageSysrepLimit .2.12.12.2.1.25 +-- acpmAvgCurrentTable .2.12.12.3 +-- acpmAvgCurrentEntry .2.12.12.3.1 +-- acpmAvgCurrentIndex .2.12.12.3.1.1 +-- acpmAvgCurrentEnable .2.12.12.3.1.2 +-- acpmAvgCurrentDeadband .2.12.12.3.1.3 +-- acpmAvgCurrentVHighValue .2.12.12.3.1.4 +-- acpmAvgCurrentVHighActions .2.12.12.3.1.5 +-- acpmAvgCurrentVHighTrapNum .2.12.12.3.1.6 +-- acpmAvgCurrentVHighClass .2.12.12.3.1.7 +-- acpmAvgCurrentHighValue .2.12.12.3.1.8 +-- acpmAvgCurrentHighActions .2.12.12.3.1.9 +-- acpmAvgCurrentHighTrapNum .2.12.12.3.1.10 +-- acpmAvgCurrentHighClass .2.12.12.3.1.11 +-- acpmAvgCurrentNormalActions .2.12.12.3.1.12 +-- acpmAvgCurrentNormalTrapNum .2.12.12.3.1.13 +-- acpmAvgCurrentNormalClass .2.12.12.3.1.14 +-- acpmAvgCurrentLowValue .2.12.12.3.1.15 +-- acpmAvgCurrentLowActions .2.12.12.3.1.16 +-- acpmAvgCurrentLowTrapNum .2.12.12.3.1.17 +-- acpmAvgCurrentLowClass .2.12.12.3.1.18 +-- acpmAvgCurrentVLowValue .2.12.12.3.1.19 +-- acpmAvgCurrentVLowActions .2.12.12.3.1.20 +-- acpmAvgCurrentVLowTrapNum .2.12.12.3.1.21 +-- acpmAvgCurrentVLowClass .2.12.12.3.1.22 +-- acpmAvgCurrentSysrepEnable .2.12.12.3.1.23 +-- acpmAvgCurrentSysrepThreshold .2.12.12.3.1.24 +-- acpmAvgCurrentSysrepLimit .2.12.12.3.1.25 +-- acpmFreqTable .2.12.12.4 +-- acpmFreqEntry .2.12.12.4.1 +-- acpmFreqIndex .2.12.12.4.1.1 +-- acpmFreqEnable .2.12.12.4.1.2 +-- acpmFreqDeadband .2.12.12.4.1.3 +-- acpmFreqVHighValue .2.12.12.4.1.4 +-- acpmFreqVHighActions .2.12.12.4.1.5 +-- acpmFreqVHighTrapNum .2.12.12.4.1.6 +-- acpmFreqVHighClass .2.12.12.4.1.7 +-- acpmFreqHighValue .2.12.12.4.1.8 +-- acpmFreqHighActions .2.12.12.4.1.9 +-- acpmFreqHighTrapNum .2.12.12.4.1.10 +-- acpmFreqHighClass .2.12.12.4.1.11 +-- acpmFreqNormalActions .2.12.12.4.1.12 +-- acpmFreqNormalTrapNum .2.12.12.4.1.13 +-- acpmFreqNormalClass .2.12.12.4.1.14 +-- acpmFreqLowValue .2.12.12.4.1.15 +-- acpmFreqLowActions .2.12.12.4.1.16 +-- acpmFreqLowTrapNum .2.12.12.4.1.17 +-- acpmFreqLowClass .2.12.12.4.1.18 +-- acpmFreqVLowValue .2.12.12.4.1.19 +-- acpmFreqVLowActions .2.12.12.4.1.20 +-- acpmFreqVLowTrapNum .2.12.12.4.1.21 +-- acpmFreqVLowClass .2.12.12.4.1.22 +-- acpmFreqSysrepEnable .2.12.12.4.1.23 +-- acpmFreqSysrepThreshold .2.12.12.4.1.24 +-- acpmFreqSysrepLimit .2.12.12.4.1.25 +-- acpmTotalRealPowerTable .2.12.12.5 +-- acpmTRPEntry .2.12.12.5.1 +-- acpmTRPIndex .2.12.12.5.1.1 +-- acpmTRPEnable .2.12.12.5.1.2 +-- acpmTRPDeadband .2.12.12.5.1.3 +-- acpmTRPVHighValue .2.12.12.5.1.4 +-- acpmTRPVHighActions .2.12.12.5.1.5 +-- acpmTRPVHighTrapNum .2.12.12.5.1.6 +-- acpmTRPVHighClass .2.12.12.5.1.7 +-- acpmTRPHighValue .2.12.12.5.1.8 +-- acpmTRPHighActions .2.12.12.5.1.9 +-- acpmTRPHighTrapNum .2.12.12.5.1.10 +-- acpmTRPHighClass .2.12.12.5.1.11 +-- acpmTRPNormalActions .2.12.12.5.1.12 +-- acpmTRPNormalTrapNum .2.12.12.5.1.13 +-- acpmTRPNormalClass .2.12.12.5.1.14 +-- acpmTRPLowValue .2.12.12.5.1.15 +-- acpmTRPLowActions .2.12.12.5.1.16 +-- acpmTRPLowTrapNum .2.12.12.5.1.17 +-- acpmTRPLowClass .2.12.12.5.1.18 +-- acpmTRPVLowValue .2.12.12.5.1.19 +-- acpmTRPVLowActions .2.12.12.5.1.20 +-- acpmTRPVLowTrapNum .2.12.12.5.1.21 +-- acpmTRPVLowClass .2.12.12.5.1.22 +-- acpmTRPSysrepEnable .2.12.12.5.1.23 +-- acpmTRPSysrepThreshold .2.12.12.5.1.24 +-- acpmTRPSysrepLimit .2.12.12.5.1.25 +-- acpmDisconnectTable .2.12.12.6 +-- acpmDisconnectEntry .2.12.12.6.1 +-- acpmDisconnectIndex .2.12.12.6.1.1 +-- acpmDisconnectEnable .2.12.12.6.1.2 +-- acpmDisconnectActions .2.12.12.6.1.3 +-- acpmDisconnectTrapNum .2.12.12.6.1.4 +-- acpmDisconnectClass .2.12.12.6.1.5 +-- acpmDisconnectNormalActions .2.12.12.6.1.6 +-- acpmDisconnectNormalTrapNum .2.12.12.6.1.7 +-- acpmDisconnectNormalClass .2.12.12.6.1.8 +-- acpmTotalPowerFactorTable .2.12.12.7 +-- acpmTPFEntry .2.12.12.7.1 +-- acpmTPFIndex .2.12.12.7.1.1 +-- acpmTPFEnable .2.12.12.7.1.2 +-- acpmTPFDeadband .2.12.12.7.1.3 +-- acpmTPFNormalActions .2.12.12.7.1.4 +-- acpmTPFNormalTrapNum .2.12.12.7.1.5 +-- acpmTPFNormalClass .2.12.12.7.1.6 +-- acpmTPFLowValue .2.12.12.7.1.7 +-- acpmTPFLowActions .2.12.12.7.1.8 +-- acpmTPFLowTrapNum .2.12.12.7.1.9 +-- acpmTPFLowClass .2.12.12.7.1.10 +-- acpmTPFVLowValue .2.12.12.7.1.11 +-- acpmTPFVLowActions .2.12.12.7.1.12 +-- acpmTPFVLowTrapNum .2.12.12.7.1.13 +-- acpmTPFVLowClass .2.12.12.7.1.14 +-- acpmTPFSysrepEnable .2.12.12.7.1.15 +-- acpmTPFSysrepThreshold .2.12.12.7.1.16 +-- acpmTPFSysrepLimit .2.12.12.7.1.17 +-- evReset .2.12.16 +-- evResetEnable .2.12.16.1 +-- evResetDelay .2.12.16.2 +-- evResetActions .2.12.16.3 +-- evResetMessage .2.12.16.4 +-- evResetTrapnum .2.12.16.5 +-- evResetClass .2.12.16.6 +-- evGlobal .2.12.18 +-- evGlobalActions .2.12.18.1 +-- evGlobalTrapnum .2.12.18.2 +-- evHVAC .2.12.19 +-- evHVACGeneral .2.12.19.1 +-- evHVACBard .2.12.19.2 +-- evHVACBardLocal .2.12.19.2.1 +-- evHVACBardIPAddress .2.12.19.2.1.1 +-- evHVACBardPort .2.12.19.2.1.2 +-- evHVACBardTimeout .2.12.19.2.1.3 +-- evHVACBardXMLStatus .2.12.19.2.1.4 +-- evHVACBardXMLSettings .2.12.19.2.1.5 +-- evHVACBardWebSettingsHTML .2.12.19.2.1.6 +-- evHVACBardAlarm .2.12.19.2.1.7 +-- evHVACBardAlarmEnable .2.12.19.2.1.7.1 +-- evHVACBardAlarmActions .2.12.19.2.1.7.2 +-- evHVACBardAlarmTrapnum .2.12.19.2.1.7.3 +-- evHVACBardAlarmClass .2.12.19.2.1.7.4 +-- evHVACBardAlarmNormalActions .2.12.19.2.1.7.5 +-- evHVACBardAlarmNormalTrapnum .2.12.19.2.1.7.6 +-- evHVACBardAlarmNormalClass .2.12.19.2.1.7.7 +-- evHVACBardReset .2.12.19.2.1.8 +-- evHVACBardDefault .2.12.19.2.1.9 +-- evHVACBardSynchronized .2.12.19.2.2 +-- evHVACBardTempScale .2.12.19.2.2.1 +-- evHVACBardCoolThreshold .2.12.19.2.2.2 +-- evHVACBardCoolThresholdState .2.12.19.2.2.3 +-- evHVACBardHeatThreshold .2.12.19.2.2.4 +-- evHVACBardHeatDiff .2.12.19.2.2.5 +-- evHVACBardHeatDiffState .2.12.19.2.2.6 +-- evHVACBardBlower .2.12.19.2.2.7 +-- evHVACBardBlowerState .2.12.19.2.2.8 +-- evHVACBardAlternate .2.12.19.2.2.9 +-- evHVACBardAlternateState .2.12.19.2.2.10 +-- evHVACBardChangeover .2.12.19.2.2.11 +-- evHVACBardChangeoverState .2.12.19.2.2.12 +-- evHVACBardBlowDiff .2.12.19.2.2.13 +-- evHVACBardBlowDiffState .2.12.19.2.2.14 +-- evHVACBardOffDelay .2.12.19.2.2.15 +-- evHVACBardOffDelayState .2.12.19.2.2.16 +-- evHVACBardRunMin .2.12.19.2.2.17 +-- evHVACBardRunMinState .2.12.19.2.2.18 +-- evHVACBardDiff .2.12.19.2.2.19 +-- evHVACBardStage1Diff .2.12.19.2.2.19.1 +-- evHVACBardStage1DiffState .2.12.19.2.2.19.2 +-- evHVACBardStage2Diff .2.12.19.2.2.19.3 +-- evHVACBardStage2DiffState .2.12.19.2.2.19.4 +-- evHVACBardStage3Diff .2.12.19.2.2.19.5 +-- evHVACBardStage3DiffState .2.12.19.2.2.19.6 +-- evHVACBardCoolDisableDb .2.12.19.2.2.20 +-- evHVACBardCoolDisableDbState .2.12.19.2.2.21 +-- evHVACBardCoolEnableDb .2.12.19.2.2.22 +-- evHVACBardCoolEnableDbState .2.12.19.2.2.23 +-- evHVACBardHeatDb .2.12.19.2.2.24 +-- evHVACBardHeatDbState .2.12.19.2.2.25 +-- evHVACBardHeatPump .2.12.19.2.2.26 +-- evHVACBardHeatPumpState .2.12.19.2.2.27 +-- evHVACBardCompressors .2.12.19.2.2.28 +-- evHVACBardCompressorsState .2.12.19.2.2.29 +-- evHVACBardEconomizer .2.12.19.2.2.30 +-- evHVACBardEconomizerState .2.12.19.2.2.31 +-- evHVACBardTemp .2.12.19.2.2.32 +-- evHVACBardTempLowValue .2.12.19.2.2.32.1 +-- evHVACBardTempLowValueState .2.12.19.2.2.32.2 +-- evHVACBardTempHighValue .2.12.19.2.2.32.3 +-- evHVACBardTempHighValueState .2.12.19.2.2.32.4 +-- evHVACBardTempVHighValue .2.12.19.2.2.32.5 +-- evHVACBardTempVHighValueState .2.12.19.2.2.32.6 +-- evHVACBardOverride .2.12.19.2.2.33 +-- evHVACBardOverrideState .2.12.19.2.2.34 +-- evHVACBardLock .2.12.19.2.2.35 +-- evHVACBardLockState .2.12.19.2.2.36 +-- evHVACBardLeadUnit .2.12.19.2.2.37 +-- evHVACBardLeadUnitState .2.12.19.2.2.38 +-- evHVACBardComfort .2.12.19.2.2.39 +-- evHVACBardComfortState .2.12.19.2.2.40 +-- evHVACAsentria .2.12.19.3 +-- evHVACAsentriaSensorListTable .2.12.19.3.1 +-- evHVACAsentriaSensorListEntry .2.12.19.3.1.1 +-- evHVACAsentriaSensorListIndex .2.12.19.3.1.1.1 +-- evHVACAsentriaSensorListES .2.12.19.3.1.1.2 +-- evHVACAsentriaSensorListPT .2.12.19.3.1.1.3 +-- evHVACAsentriaSensorListType .2.12.19.3.1.1.4 +-- evHVACAsentriaSensorListLoc .2.12.19.3.1.1.5 +-- evHVACAsentriaOverride .2.12.19.3.2 +-- evHVACAsentriaSchedule .2.12.19.3.3 +-- evHVACAsentriaPrimary .2.12.19.3.4 +-- evHVACAsentriaMethod .2.12.19.3.5 +-- evHVACAsentriaAlarm .2.12.19.3.6 +-- evHVACAsentriaAlarmLagNormEnable .2.12.19.3.6.1 +-- evHVACAsentriaAlarmLagNormActions .2.12.19.3.6.2 +-- evHVACAsentriaAlarmLagNormTrapNum .2.12.19.3.6.3 +-- evHVACAsentriaAlarmLagNormClass .2.12.19.3.6.4 +-- evHVACAsentriaAlarmLagVentEnable .2.12.19.3.6.5 +-- evHVACAsentriaAlarmLagVentActions .2.12.19.3.6.6 +-- evHVACAsentriaAlarmLagVentTrapNum .2.12.19.3.6.7 +-- evHVACAsentriaAlarmLagVentClass .2.12.19.3.6.8 +-- evHVACAsentriaAlarmLagCoolEnable .2.12.19.3.6.9 +-- evHVACAsentriaAlarmLagCoolActions .2.12.19.3.6.10 +-- evHVACAsentriaAlarmLagCoolTrapNum .2.12.19.3.6.11 +-- evHVACAsentriaAlarmLagCoolClass .2.12.19.3.6.12 +-- evHVACAsentriaAlarmLagHeatEnable .2.12.19.3.6.13 +-- evHVACAsentriaAlarmLagHeatActions .2.12.19.3.6.14 +-- evHVACAsentriaAlarmLagHeatTrapNum .2.12.19.3.6.15 +-- evHVACAsentriaAlarmLagHeatClass .2.12.19.3.6.16 +-- evHVACAsentriaFire .2.12.19.3.7 +-- evHVACAsentriaFireES .2.12.19.3.7.1 +-- evHVACAsentriaFirePT .2.12.19.3.7.2 +-- evHVACAsentriaFireActions .2.12.19.3.7.3 +-- evHVACAsentriaFireTrapNum .2.12.19.3.7.4 +-- evHVACAsentriaFireClass .2.12.19.3.7.5 +-- evHVACAsentriaFireNormActions .2.12.19.3.7.6 +-- evHVACAsentriaFireNormTrapNum .2.12.19.3.7.7 +-- evHVACAsentriaFireNormClass .2.12.19.3.7.8 +-- evHVACAsentriaUnitTable .2.12.19.3.8 +-- evHVACAsentriaUnitEntry .2.12.19.3.8.1 +-- evHVACAsentriaUnitIndex .2.12.19.3.8.1.1 +-- evHVACAsentriaUnitEnable .2.12.19.3.8.1.2 +-- evHVACAsentriaUnitFanRelayES .2.12.19.3.8.1.3 +-- evHVACAsentriaUnitFanRelayPT .2.12.19.3.8.1.4 +-- evHVACAsentriaUnitVentRelayES .2.12.19.3.8.1.5 +-- evHVACAsentriaUnitVentRelayPT .2.12.19.3.8.1.6 +-- evHVACAsentriaUnitTimereset .2.12.19.3.8.1.7 +-- evHVACAsentriaSeqTimereset .2.12.19.3.8.1.8 +-- evHVACAsentriaUnitStage1CoolES .2.12.19.3.8.1.20 +-- evHVACAsentriaUnitStage1CoolPT .2.12.19.3.8.1.21 +-- evHVACAsentriaUnitStage1HeatES .2.12.19.3.8.1.22 +-- evHVACAsentriaUnitStage1HeatPT .2.12.19.3.8.1.23 +-- evHVACAsentriaUnitStage2CoolES .2.12.19.3.8.1.30 +-- evHVACAsentriaUnitStage2CoolPT .2.12.19.3.8.1.31 +-- evHVACAsentriaUnitStage2HeatES .2.12.19.3.8.1.32 +-- evHVACAsentriaUnitStage2HeatPT .2.12.19.3.8.1.33 +-- evHVACAsentriaTemp .2.12.19.3.9 +-- evHVACAsentriaTempScale .2.12.19.3.9.1 +-- evHVACAsentriaTempCoolThresh .2.12.19.3.9.2 +-- evHVACAsentriaTempHeatThresh .2.12.19.3.9.3 +-- evHVACAsentriaTempEnable .2.12.19.3.9.4 +-- evHVACAsentriaTempEventDeadband .2.12.19.3.9.5 +-- evHVACAsentriaTempVLowValue .2.12.19.3.9.6 +-- evHVACAsentriaTempVLowActions .2.12.19.3.9.7 +-- evHVACAsentriaTempVLowTrapNum .2.12.19.3.9.8 +-- evHVACAsentriaTempVLowClass .2.12.19.3.9.9 +-- evHVACAsentriaTempLowValue .2.12.19.3.9.10 +-- evHVACAsentriaTempLowActions .2.12.19.3.9.11 +-- evHVACAsentriaTempLowTrapNum .2.12.19.3.9.12 +-- evHVACAsentriaTempLowClass .2.12.19.3.9.13 +-- evHVACAsentriaTempNormalActions .2.12.19.3.9.14 +-- evHVACAsentriaTempNormalTrapNum .2.12.19.3.9.15 +-- evHVACAsentriaTempNormalClass .2.12.19.3.9.16 +-- evHVACAsentriaTempHighValue .2.12.19.3.9.17 +-- evHVACAsentriaTempHighActions .2.12.19.3.9.18 +-- evHVACAsentriaTempHighTrapNum .2.12.19.3.9.19 +-- evHVACAsentriaTempHighClass .2.12.19.3.9.20 +-- evHVACAsentriaTempVHighValue .2.12.19.3.9.21 +-- evHVACAsentriaTempVHighActions .2.12.19.3.9.22 +-- evHVACAsentriaTempVHighTrapNum .2.12.19.3.9.23 +-- evHVACAsentriaTempVHighClass .2.12.19.3.9.24 +-- evHVACAsentriaTempDeadband .2.12.19.3.9.25 +-- evHVACAsentriaTempDifference .2.12.19.3.9.26 +-- evHVACAsentriaHumid .2.12.19.3.10 +-- evHVACAsentriaHumidInThresh .2.12.19.3.10.2 +-- evHVACAsentriaHumidOutThresh .2.12.19.3.10.3 +-- evHVACAsentriaHumidEnable .2.12.19.3.10.4 +-- evHVACAsentriaHumidEventDeadband .2.12.19.3.10.5 +-- evHVACAsentriaHumidVLowValue .2.12.19.3.10.6 +-- evHVACAsentriaHumidVLowActions .2.12.19.3.10.7 +-- evHVACAsentriaHumidVLowTrapNum .2.12.19.3.10.8 +-- evHVACAsentriaHumidVLowClass .2.12.19.3.10.9 +-- evHVACAsentriaHumidLowValue .2.12.19.3.10.10 +-- evHVACAsentriaHumidLowActions .2.12.19.3.10.11 +-- evHVACAsentriaHumidLowTrapNum .2.12.19.3.10.12 +-- evHVACAsentriaHumidLowClass .2.12.19.3.10.13 +-- evHVACAsentriaHumidNormalActions .2.12.19.3.10.14 +-- evHVACAsentriaHumidNormalTrapNum .2.12.19.3.10.15 +-- evHVACAsentriaHumidNormalClass .2.12.19.3.10.16 +-- evHVACAsentriaHumidHighValue .2.12.19.3.10.17 +-- evHVACAsentriaHumidHighActions .2.12.19.3.10.18 +-- evHVACAsentriaHumidHighTrapNum .2.12.19.3.10.19 +-- evHVACAsentriaHumidHighClass .2.12.19.3.10.20 +-- evHVACAsentriaHumidVHighValue .2.12.19.3.10.21 +-- evHVACAsentriaHumidVHighActions .2.12.19.3.10.22 +-- evHVACAsentriaHumidVHighTrapNum .2.12.19.3.10.23 +-- evHVACAsentriaHumidVHighClass .2.12.19.3.10.24 +-- evHVACAsentriaHumidDeadband .2.12.19.3.10.25 +-- evHVACAsentriaHumidDifference .2.12.19.3.10.26 +-- evHVACAirsys .2.12.19.4 +-- evHVACAirsysGeneral .2.12.19.4.1 +-- evHVACAirsysGeneratorLogic .2.12.19.4.1.1 +-- evHVACAirsysFreeMode .2.12.19.4.1.2 +-- evHVACAirsysRemoteEnable .2.12.19.4.1.3 +-- evHVACAirsysHVACRotation .2.12.19.4.1.4 +-- evHVACAirsysRotationRuntime .2.12.19.4.1.5 +-- evHVACAirsysAlarm .2.12.19.4.2 +-- evHVACAirsysUnitTable .2.12.19.4.2.1 +-- evHVACAirsysUnitEntry .2.12.19.4.2.1.1 +-- evHVACAirsysUnitIndex .2.12.19.4.2.1.1.1 +-- evHVACAirsysULowPEnable .2.12.19.4.2.1.1.2 +-- evHVACAirsysULowPActions .2.12.19.4.2.1.1.3 +-- evHVACAirsysULowPClass .2.12.19.4.2.1.1.4 +-- evHVACAirsysULowPTrapNum .2.12.19.4.2.1.1.5 +-- evHVACAirsysULowPNormActions .2.12.19.4.2.1.1.6 +-- evHVACAirsysULowPNormClass .2.12.19.4.2.1.1.7 +-- evHVACAirsysULowPNormTrapNum .2.12.19.4.2.1.1.8 +-- evHVACAirsysUHighPEnable .2.12.19.4.2.1.1.9 +-- evHVACAirsysUHighPActions .2.12.19.4.2.1.1.10 +-- evHVACAirsysUHighPClass .2.12.19.4.2.1.1.11 +-- evHVACAirsysUHighPTrapNum .2.12.19.4.2.1.1.12 +-- evHVACAirsysUHighPNormActions .2.12.19.4.2.1.1.13 +-- evHVACAirsysUHighPNormClass .2.12.19.4.2.1.1.14 +-- evHVACAirsysUHighPNormTrapNum .2.12.19.4.2.1.1.15 +-- evHVACAirsysUEvapFanEnable .2.12.19.4.2.1.1.16 +-- evHVACAirsysUEvapFanActions .2.12.19.4.2.1.1.17 +-- evHVACAirsysUEvapFanClass .2.12.19.4.2.1.1.18 +-- evHVACAirsysUEvapFanTrapNum .2.12.19.4.2.1.1.19 +-- evHVACAirsysUEvapFanNormActions .2.12.19.4.2.1.1.20 +-- evHVACAirsysUEvapFanNormClass .2.12.19.4.2.1.1.21 +-- evHVACAirsysUEvapFanNormTrapNum .2.12.19.4.2.1.1.22 +-- evHVACAirsysUDirtyEnable .2.12.19.4.2.1.1.23 +-- evHVACAirsysUDirtyActions .2.12.19.4.2.1.1.24 +-- evHVACAirsysUDirtyClass .2.12.19.4.2.1.1.25 +-- evHVACAirsysUDirtyTrapNum .2.12.19.4.2.1.1.26 +-- evHVACAirsysUDirtyNormActions .2.12.19.4.2.1.1.27 +-- evHVACAirsysUDirtyNormClass .2.12.19.4.2.1.1.28 +-- evHVACAirsysUDirtyNormTrapNum .2.12.19.4.2.1.1.29 +-- evHVACAirsysUInProbeEnable .2.12.19.4.2.1.1.30 +-- evHVACAirsysUInProbeActions .2.12.19.4.2.1.1.31 +-- evHVACAirsysUInProbeClass .2.12.19.4.2.1.1.32 +-- evHVACAirsysUInProbeTrapNum .2.12.19.4.2.1.1.33 +-- evHVACAirsysUInProbeNormActions .2.12.19.4.2.1.1.34 +-- evHVACAirsysUInProbeNormClass .2.12.19.4.2.1.1.35 +-- evHVACAirsysUInProbeNormTrapNum .2.12.19.4.2.1.1.36 +-- evHVACAirsysUDamperEnable .2.12.19.4.2.1.1.37 +-- evHVACAirsysUDamperActions .2.12.19.4.2.1.1.38 +-- evHVACAirsysUDamperClass .2.12.19.4.2.1.1.39 +-- evHVACAirsysUDamperTrapNum .2.12.19.4.2.1.1.40 +-- evHVACAirsysUDamperNormActions .2.12.19.4.2.1.1.41 +-- evHVACAirsysUDamperNormClass .2.12.19.4.2.1.1.42 +-- evHVACAirsysUDamperNormTrapNum .2.12.19.4.2.1.1.43 +-- evHVACAirsysUSupProbeEnable .2.12.19.4.2.1.1.44 +-- evHVACAirsysUSupProbeActions .2.12.19.4.2.1.1.45 +-- evHVACAirsysUSupProbeClass .2.12.19.4.2.1.1.46 +-- evHVACAirsysUSupProbeTrapNum .2.12.19.4.2.1.1.47 +-- evHVACAirsysUSupProbeNormActions .2.12.19.4.2.1.1.48 +-- evHVACAirsysUSupProbeNormClass .2.12.19.4.2.1.1.49 +-- evHVACAirsysUSupProbeNormTrapNum .2.12.19.4.2.1.1.50 +-- evHVACAirsysSmokeFireEnable .2.12.19.4.2.2 +-- evHVACAirsysSmokeFireAction .2.12.19.4.2.3 +-- evHVACAirsysSmokeFireClass .2.12.19.4.2.4 +-- evHVACAirsysSmokeFireTrapNum .2.12.19.4.2.5 +-- evHVACAirsysSmokeFireNormAction .2.12.19.4.2.6 +-- evHVACAirsysSmokeFireNormClass .2.12.19.4.2.7 +-- evHVACAirsysSmokeFireNormTrapNum .2.12.19.4.2.8 +-- evHVACAirsysLowRoomTempEnable .2.12.19.4.2.9 +-- evHVACAirsysLowRoomTempAction .2.12.19.4.2.10 +-- evHVACAirsysLowRoomTempClass .2.12.19.4.2.11 +-- evHVACAirsysLowRoomTempTrapNum .2.12.19.4.2.12 +-- evHVACAirsysLowRoomTempNormAction .2.12.19.4.2.13 +-- evHVACAirsysLowRoomTempNormClass .2.12.19.4.2.14 +-- evHVACAirsysLowRoomTempNormTrapNum .2.12.19.4.2.15 +-- evHVACAirsysHighRoomTempEnable .2.12.19.4.2.16 +-- evHVACAirsysHighRoomTempAction .2.12.19.4.2.17 +-- evHVACAirsysHighRoomTempClass .2.12.19.4.2.18 +-- evHVACAirsysHighRoomTempTrapNum .2.12.19.4.2.19 +-- evHVACAirsysHighRoomTempNormAction .2.12.19.4.2.20 +-- evHVACAirsysHighRoomTempNormClass .2.12.19.4.2.21 +-- evHVACAirsysHighRoomTempNormTrapNum .2.12.19.4.2.22 +-- evHVACAirsysPowerEnable .2.12.19.4.2.23 +-- evHVACAirsysPowerAction .2.12.19.4.2.24 +-- evHVACAirsysPowerClass .2.12.19.4.2.25 +-- evHVACAirsysPowerTrapNum .2.12.19.4.2.26 +-- evHVACAirsysPowerNormAction .2.12.19.4.2.27 +-- evHVACAirsysPowerNormClass .2.12.19.4.2.28 +-- evHVACAirsysPowerNormTrapNum .2.12.19.4.2.29 +-- evHVACAirsyspLANEnable .2.12.19.4.2.30 +-- evHVACAirsyspLANAction .2.12.19.4.2.31 +-- evHVACAirsyspLANClass .2.12.19.4.2.32 +-- evHVACAirsyspLANTrapNum .2.12.19.4.2.33 +-- evHVACAirsyspLANNormAction .2.12.19.4.2.34 +-- evHVACAirsyspLANNormClass .2.12.19.4.2.35 +-- evHVACAirsyspLANNormTrapNum .2.12.19.4.2.36 +-- evHVACAirsysClockEnable .2.12.19.4.2.37 +-- evHVACAirsysClockAction .2.12.19.4.2.38 +-- evHVACAirsysClockClass .2.12.19.4.2.39 +-- evHVACAirsysClockTrapNum .2.12.19.4.2.40 +-- evHVACAirsysClockNormAction .2.12.19.4.2.41 +-- evHVACAirsysClockNormClass .2.12.19.4.2.42 +-- evHVACAirsysClockNormTrapNum .2.12.19.4.2.43 +-- evHVACAirsysHumidProbeEnable .2.12.19.4.2.44 +-- evHVACAirsysHumidProbeAction .2.12.19.4.2.45 +-- evHVACAirsysHumidProbeClass .2.12.19.4.2.46 +-- evHVACAirsysHumidProbeTrapNum .2.12.19.4.2.47 +-- evHVACAirsysHumidProbeNormAction .2.12.19.4.2.48 +-- evHVACAirsysHumidProbeNormClass .2.12.19.4.2.49 +-- evHVACAirsysHumidProbeNormTrapNum .2.12.19.4.2.50 +-- evHVACAirsysOutProbeEnable .2.12.19.4.2.51 +-- evHVACAirsysOutProbeAction .2.12.19.4.2.52 +-- evHVACAirsysOutProbeClass .2.12.19.4.2.53 +-- evHVACAirsysOutProbeTrapNum .2.12.19.4.2.54 +-- evHVACAirsysOutProbeNormAction .2.12.19.4.2.55 +-- evHVACAirsysOutProbeNormClass .2.12.19.4.2.56 +-- evHVACAirsysOutProbeNormTrapNum .2.12.19.4.2.57 +-- evHVACAirsysBothCompressEnable .2.12.19.4.2.58 +-- evHVACAirsysBothCompressAction .2.12.19.4.2.59 +-- evHVACAirsysBothCompressClass .2.12.19.4.2.60 +-- evHVACAirsysBothCompressTrapNum .2.12.19.4.2.61 +-- evHVACAirsysBothCompressNormAction .2.12.19.4.2.62 +-- evHVACAirsysBothCompressNormClass .2.12.19.4.2.63 +-- evHVACAirsysBothCompressNormTrapNum .2.12.19.4.2.64 +-- evHVACAirsysGeneratorEnable .2.12.19.4.2.65 +-- evHVACAirsysGeneratorAction .2.12.19.4.2.66 +-- evHVACAirsysGeneratorClass .2.12.19.4.2.67 +-- evHVACAirsysGeneratorTrapNum .2.12.19.4.2.68 +-- evHVACAirsysGeneratorNormAction .2.12.19.4.2.69 +-- evHVACAirsysGeneratorNormClass .2.12.19.4.2.70 +-- evHVACAirsysGeneratorNormTrapNum .2.12.19.4.2.71 +-- evHVACAirsysConnectionEnable .2.12.19.4.2.72 +-- evHVACAirsysConnectionAction .2.12.19.4.2.73 +-- evHVACAirsysConnectionClass .2.12.19.4.2.74 +-- evHVACAirsysConnectionTrapNum .2.12.19.4.2.75 +-- evHVACAirsysConnectionNormAction .2.12.19.4.2.76 +-- evHVACAirsysConnectionNormClass .2.12.19.4.2.77 +-- evHVACAirsysConnectionNormTrapNum .2.12.19.4.2.78 +-- evHVACAirsysTemp .2.12.19.4.3 +-- evHVACAirsysTempBaseThresh .2.12.19.4.3.1 +-- evHVACAirsysTempCoolDeadband .2.12.19.4.3.2 +-- evHVACAirsysTempHeatDeadband .2.12.19.4.3.3 +-- evHVACAirsysTempHighValue .2.12.19.4.3.4 +-- evHVACAirsysTempLowValue .2.12.19.4.3.5 +-- evHVACAirsysHumid .2.12.19.4.4 +-- evHVACAirsysHumidMaxFree .2.12.19.4.4.1 +-- evHVACAirsysHumidDeadband .2.12.19.4.4.2 +-- evEvps .2.12.20 +-- evpsEnable .2.12.20.1 +-- evpsIPAddress .2.12.20.2 +-- evpsPort .2.12.20.3 +-- evpsTimeout .2.12.20.4 +-- accessControl .2.12.21 +-- acActions .2.12.21.2 +-- acTrapnum .2.12.21.3 +-- acClass .2.12.21.4 +-- accessControlDeviceTable .2.12.21.10 +-- accessControlDeviceEntry .2.12.21.10.1 +-- acdIndex .2.12.21.10.1.1 +-- acdEnable .2.12.21.10.1.2 +-- acdName .2.12.21.10.1.3 +-- acdReader .2.12.21.10.1.4 +-- acdWiegandES .2.12.21.10.1.5 +-- acdWiegandPoint .2.12.21.10.1.6 +-- acdRelayType .2.12.21.10.1.7 +-- acdRelayES .2.12.21.10.1.8 +-- acdRelayPoint .2.12.21.10.1.9 +-- acdOpenTime .2.12.21.10.1.10 +-- acdUserGroup .2.12.21.10.1.11 +-- accessControlUserTable .2.12.21.11 +-- accessControlUserEntry .2.12.21.11.1 +-- acuIndexUserGroup .2.12.21.11.1.1 +-- acuIndexUser .2.12.21.11.1.2 +-- acuEnable .2.12.21.11.1.3 +-- acuName .2.12.21.11.1.4 +-- acuSn .2.12.21.11.1.5 +-- acuSunBegin .2.12.21.11.1.6 +-- acuSunEnd .2.12.21.11.1.7 +-- acuMonBegin .2.12.21.11.1.8 +-- acuMonEnd .2.12.21.11.1.9 +-- acuTueBegin .2.12.21.11.1.10 +-- acuTueEnd .2.12.21.11.1.11 +-- acuWedBegin .2.12.21.11.1.12 +-- acuWedEnd .2.12.21.11.1.13 +-- acuThuBegin .2.12.21.11.1.14 +-- acuThuEnd .2.12.21.11.1.15 +-- acuFriBegin .2.12.21.11.1.16 +-- acuFriEnd .2.12.21.11.1.17 +-- acuSatBegin .2.12.21.11.1.18 +-- acuSatEnd .2.12.21.11.1.19 +-- telemetry .2.12.22 +-- telemetryTable .2.12.22.1 +-- telemetryTableEntry .2.12.22.1.1 +-- telemetryPointIndex .2.12.22.1.1.1 +-- telemetryPointName .2.12.22.1.1.2 +-- telemetryPointKey .2.12.22.1.1.3 +-- telemetryPointType .2.12.22.1.1.4 +-- telemetryPointClass .2.12.22.1.1.5 +-- telemetryPointDeadband .2.12.22.1.1.6 +-- telemetryPointShortcode .2.12.22.1.1.7 +-- siteSecurity .2.12.23 +-- siteSecIntrusionTable .2.12.23.1 +-- siteSecEnable .2.12.23.1.1 +-- siteSecDisarmed .2.12.23.1.2 +-- siteSecName .2.12.23.1.3 +-- siteSecState .2.12.23.1.4 +-- siteSecSensorES .2.12.23.1.5 +-- siteSecSensorPoint .2.12.23.1.6 +-- siteSecIntrusionThreshold .2.12.23.1.7 +-- siteSecReader .2.12.23.1.8 +-- siteSecReaderThreshold .2.12.23.1.9 +-- siteSecButtonEnable .2.12.23.1.10 +-- siteSecButtonES .2.12.23.1.11 +-- siteSecButtonPoint .2.12.23.1.12 +-- siteSecButtonType .2.12.23.1.13 +-- siteSecButtonThresholdArm .2.12.23.1.14 +-- siteSecButtonThresholdDisarm .2.12.23.1.15 +-- siteSecSirenEnable .2.12.23.1.16 +-- siteSecSirenES .2.12.23.1.17 +-- siteSecSirenPoint .2.12.23.1.18 +-- siteSecRearmDelay .2.12.23.1.19 +-- siteSecMotionTable .2.12.23.2 +-- siteSecMotionES .2.12.23.2.1 +-- siteSecMotionPoint .2.12.23.2.2 +-- siteSecMotionEnable .2.12.23.2.3 +-- siteSecMotionName .2.12.23.2.4 +-- siteSecMotionThresholdRearm .2.12.23.2.5 +-- siteSecDoorAjarTable .2.12.23.3 +-- siteSecDoorAjarEnable .2.12.23.3.1 +-- siteSecDoorAjarName .2.12.23.3.2 +-- siteSecDoorAjarES .2.12.23.3.3 +-- siteSecDoorAjarPoint .2.12.23.3.4 +-- siteSecDoorAjarThresholdNormal .2.12.23.3.5 +-- siteSecDoorAjarThresholdExtraTime .2.12.23.3.6 +-- action .2. +-- actionCallNumberTable .2.14.1 +-- actionCallNumberEntry .2.14.1.1 +-- actionCallNumberIndex .2.14.1.1.1 +-- actionCallNumber .2.14.1.1.2 +-- actionPagerTable .2.14.2 +-- actionPagerEntry .2.14.2.1 +-- actionPagerIndex .2.14.2.1.1 +-- actionPagerType .2.14.2.1.2 +-- actionPagerNumber .2.14.2.1.3 +-- actionPagerID .2.14.2.1.4 +-- actionPagerMessage .2.14.2.1.5 +-- actionPagerPostCalloutDelay .2.14.2.1.6 +-- actionPagerPostIDDelay .2.14.2.1.7 +-- actionSched .2.14.3 +-- actionSchedEnable .2.14.3.1 +-- actionSchedBegin .2.14.3.2 +-- actionSchedEnd .2.14.3.3 +-- actionSchedWeekdaysOnly .2.14.3.4 +-- actionAsentria .2.14.4 +-- actionAsentriaRequireAck .2.14.4.1 +-- actionAsentriaVersion .2.14.4.2 +-- actionAsentriaTCPPort .2.14.4.3 +-- actionHostTable .2.14.6 +-- actionHostEntry .2.14.6.1 +-- actionHostIndex .2.14.6.1.1 +-- actionHost .2.14.6.1.2 +-- actionEmailTable .2.14.7 +-- actionEmailEntry .2.14.7.1 +-- actionEmailIndex .2.14.7.1.1 +-- actionEmail .2.14.7.1.2 +-- actionParseError .2.14.8 +-- sys .2.16 +-- sysTime .2.16.1 +-- sysTimeAutoDST .2.16.1.1 +-- sysTimeGMTOffset .2.16.1.2 +-- sysTimeGMTDirection .2.16.1.3 +-- sysTimeNet .2.16.1.4 +-- sysTimeNetEnable .2.16.1.4.1 +-- sysTimeNetHostTable .2.16.1.4.2 +-- sysTimeNetHostEntry .2.16.1.4.2.1 +-- sysTimeNetHostIndex .2.16.1.4.2.1.1 +-- sysTimeNetHost .2.16.1.4.2.1.2 +-- sysPT .2.16.2 +-- sysPTTimeout .2.16.2.1 +-- sysPTEndPause .2.16.2.2 +-- sysPTJoinable .2.16.2.3 +-- sysMTU .2.16.3 +-- sysAnswerString .2.16.4 +-- sysEventFileID .2.16.6 +-- sysEscapeCharacter .2.16.7 +-- sysTimeStamp .2.16.8 +-- sysTimeStampTimeFormat .2.16.8.1 +-- sysTimeStampDateFormat .2.16.8.2 +-- sysTimeStampSpaceAfter .2.16.8.3 +-- sysLog .2.16.9 +-- sysLogMode .2.16.9.1 +-- sysLoghost .2.16.9.2 +-- sysLogFilter .2.16.9.3 +-- sysLogFileSize .2.16.9.4 +-- sysLogFileCount .2.16.9.5 +-- sysLogListenPort .2.16.9.6 +-- sysCRDB .2.16.10 +-- sysCRDBCapacity .2.16.10.1 +-- sysCRDBPercentFull .2.16.10.2 +-- sysCRDBFileIDTable .2.16.10.3 +-- sysCRDBFileIDEntry .2.16.10.3.1 +-- sysCRDBFileIDIndex .2.16.10.3.1.1 +-- sysCRDBFileID .2.16.10.3.1.2 +-- sysCRDBFileEnforceMinTable .2.16.10.4 +-- sysCRDBFileEnforceMinEntry .2.16.10.4.1 +-- sysCRDBFileEnforceMinIndex .2.16.10.4.1.1 +-- sysCRDBFileEnforceMin .2.16.10.4.1.2 +-- sysCharMask .2.16.11 +-- sysPrompt .2.16.12 +-- sysBootStatus .2.16.13 +-- sysLoc .2.16.14 +-- sysLocLatitude .2.16.14.1 +-- sysLocLongitude .2.16.14.2 +-- sysLocXOffset .2.16.14.3 +-- sysLocYOffset .2.16.14.4 +-- sysLocAngle .2.16.14.5 +-- sysLocAltitude .2.16.14.6 +-- sysAssetMgmt .2.16.15 +-- sysAMManufacturer .2.16.15.1 +-- sysAMProduct .2.16.15.2 +-- sysAMSerialNumber .2.16.15.3 +-- sysAMHardwareOptions .2.16.15.4 +-- sysAMSoftwareVersion .2.16.15.5 +-- sysAMSiteName .2.16.15.6 +-- sysFileTransfer .2.16.17 +-- sysFileTransferStatus .2.16.17.1 +-- sysFileTransferURL .2.16.17.2 +-- sysFileTransferUsername .2.16.17.3 +-- sysFileTransferPassword .2.16.17.4 +-- sysUpdate .2.16.18 +-- sysUpdateStatus .2.16.18.1 +-- auditLog .2.17 +-- auditLogEnable .2.17.1 +-- auditLogStoreResets .2.17.2 +-- auditLogStoreCommands .2.17.3 +-- auditLogStoreOutputs .2.17.4 +-- auditLogStoreAlarmActions .2.17.5 +-- auditLogStorePwdFailures .2.17.6 +-- auditLogStoreLogins .2.17.7 +-- auditLogStoreSHSK .2.17.8 +-- auditLogStorePassthrough .2.17.9 +-- auditLogStoreInactivity .2.17.10 +-- auditLogStorePolling .2.17.11 +-- auditLogMaxSize .2.17.12 +-- scripting .2.18 +-- scrGlobalEnable .2.18.1 +-- scrDTRCtrlPortEnableTable .2.18.2 +-- scrDTRCtrlPortEnableEnabletry .2.18.2.1 +-- scrDTRCtrlPortEnableIndex .2.18.2.1.1 +-- scrDTRCtrlPortEnable .2.18.2.1.2 +-- scrTable .2.18.3 +-- scrEntry .2.18.3.1 +-- scrIndex .2.18.3.1.1 +-- scrEnable .2.18.3.1.2 +-- scrName .2.18.3.1.3 +-- scrFilename .2.18.3.1.4 +-- scrRunAlways .2.18.3.1.5 +-- scrRunAtStartup .2.18.3.1.6 +-- scrRunScheduled .2.18.3.1.7 +-- scrScheduleTime .2.18.3.1.8 +-- scrArguments .2.18.3.1.9 +-- scrRepeatInterval .2.18.3.1.10 +-- scrVolatileStringTable .2.18.4 +-- scrVolatileStringEntry .2.18.4.1 +-- scrVolatileStringIndex .2.18.4.1.1 +-- scrVolatileString .2.18.4.1.2 +-- scrVolatileIntTable .2.18.5 +-- scrVolatileIntEntry .2.18.5.1 +-- scrVolatileIntIndex .2.18.5.1.1 +-- scrVolatileInt .2.18.5.1.2 +-- scrNonVolatileStringTable .2.18.6 +-- scrNonVolatileStringEntry .2.18.6.1 +-- scrNonVolatileStringIndex .2.18.6.1.1 +-- scrNonVolatileString .2.18.6.1.2 +-- scrNonVolatileIntTable .2.18.7 +-- scrNonVolatileIntEntry .2.18.7.1 +-- scrNonVolatileIntIndex .2.18.7.1.1 +-- scrNonVolatileInt .2.18.7.1.2 +-- generator .2.19 +-- genSet .2.19.1 +-- genSetEnable .2.19.1.1 +-- genSetRelay .2.19.1.2 +-- genSetRelayEs .2.19.1.2.1 +-- genSetRelayPoint .2.19.1.2.2 +-- genSetRelayRunningstate .2.19.1.2.3 +-- genSetRelayTable .2.19.1.2.5 +-- genSetRelayTableEntry .2.19.1.2.5.1 +-- genSetRelayTableIndex .2.19.1.2.5.1.1 +-- genSetRelayTableEnable .2.19.1.2.5.1.2 +-- genSetRelayTableEs .2.19.1.2.5.1.3 +-- genSetRelayTablePoint .2.19.1.2.5.1.4 +-- genSetRelayTableRunningstate .2.19.1.2.5.1.5 +-- genSetCc .2.19.1.3 +-- genSetCcEnable .2.19.1.3.1 +-- genSetCcEs .2.19.1.3.2 +-- genSetCcPoint .2.19.1.3.3 +-- genSetCcRunningstate .2.19.1.3.4 +-- genSetCCDelay .2.19.1.3.5 +-- genRun .2.19.2 +-- genRunMode .2.19.2.1 +-- genRunSched .2.19.2.2 +-- genRunDuration .2.19.2.3 +-- genRunForce .2.19.2.4 +-- genRunReqasm .2.19.2.5 +-- genRunStatus .2.19.2.6 +-- genRunNonstartEvent .2.19.2.7 +-- genRunNonstartEventEnable .2.19.2.7.1 +-- genRunNonstartEventActions .2.19.2.7.2 +-- genRunNonstartEventTrap .2.19.2.7.3 +-- genRunNonstartEventClass .2.19.2.7.4 +-- calendar .2.20 +-- schedTable .2.20.1 +-- schedEntry .2.20.1.1 +-- schedIndex .2.20.1.1.1 +-- schedEnable .2.20.1.1.2 +-- schedStart .2.20.1.1.3 +-- schedRepeatMode .2.20.1.1.4 +-- schedRepeatFreq .2.20.1.1.5 +-- schedRepeatEndMode .2.20.1.1.6 +-- schedRepeatEndAfter .2.20.1.1.7 +-- schedRepeatEndOn .2.20.1.1.8 +-- schedRepeatWeeklySun .2.20.1.1.9 +-- schedRepeatWeeklyMon .2.20.1.1.10 +-- schedRepeatWeeklyTue .2.20.1.1.11 +-- schedRepeatWeeklyWed .2.20.1.1.12 +-- schedRepeatWeeklyThu .2.20.1.1.13 +-- schedRepeatWeeklyFri .2.20.1.1.14 +-- schedRepeatWeeklySat .2.20.1.1.15 +-- schedRepeatMonthlyMode .2.20.1.1.16 +-- schedRepeatMonthlyDates .2.20.1.1.17 +-- schedRepeatMonthlyOnThe .2.20.1.1.18 +-- schedRepeatMonthlyOnDay .2.20.1.1.19 +-- schedRepeatYearlyJan .2.20.1.1.20 +-- schedRepeatYearlyFeb .2.20.1.1.21 +-- schedRepeatYearlyMar .2.20.1.1.22 +-- schedRepeatYearlyApr .2.20.1.1.23 +-- schedRepeatYearlyMay .2.20.1.1.24 +-- schedRepeatYearlyJun .2.20.1.1.25 +-- schedRepeatYearlyJul .2.20.1.1.26 +-- schedRepeatYearlyAug .2.20.1.1.27 +-- schedRepeatYearlySep .2.20.1.1.28 +-- schedRepeatYearlyOct .2.20.1.1.29 +-- schedRepeatYearlyNov .2.20.1.1.30 +-- schedRepeatYearlyDec .2.20.1.1.31 +-- schedRepeatYearlyOnThe .2.20.1.1.32 +-- schedRepeatYearlyOnDay .2.20.1.1.33 +-- schedNextTrigger .2.20.1.1.34 + +-- productIds .3 +-- siteName 3.1 +-- thisProduct .3.2 +-- stockTrapString .3.3 +-- trapEventTypeNumber .3.4 +-- trapEventTypeName .3.5 +-- trapIncludedValue .3.6 +-- trapIncludedString .3.7 +-- trapTypeString .3.8 +-- trapEventClassNumber .3.9 +-- trapEventClassName .3.10 + +-- keyInterface .4.0 + + +--*************************************************************************************** +--TOP-LEVEL OBJECT IDENTIFIERS +--*************************************************************************************** + +s550notifications OBJECT IDENTIFIER ::= { s550 0 } + --1.3.6.1.4.1.3052.10.0 + + status OBJECT IDENTIFIER ::= { s550 1 } + --1.3.6.1.4.1.3052.10.1 + + eventSensorStatus OBJECT IDENTIFIER ::= { status 1 } + --1.3.6.1.4.1.3052.10.1.1 + + dataEventStatus OBJECT IDENTIFIER ::= { status 2 } + --1.3.6.1.4.1.3052.10.1.2 + + powerDistributionStatus OBJECT IDENTIFIER ::= { status 5 } + --1.3.6.1.4.1.3052.10.1.5 + + pdNextGen OBJECT IDENTIFIER ::= { powerDistributionStatus 4 } + --1.3.6.1.4.1.3052.10.1.5.4 + + pdSystem OBJECT IDENTIFIER ::= { powerDistributionStatus 5 } + --1.3.6.1.4.1.3052.10.1.5.5 + + fuelSensorStatus OBJECT IDENTIFIER ::= { status 6 } + --1.3.6.1.4.1.3052.10.1.6 + + wirelessModemStatus OBJECT IDENTIFIER ::= { status 7 } + --1.3.6.1.4.1.3052.10.1.7 + + acPowerMonitorStatus OBJECT IDENTIFIER ::= { status 8 } + --1.3.6.1.4.1.3052.10.1.8 + + evHVACStatus OBJECT IDENTIFIER ::= { status 11 } + --1.3.6.1.4.1.3052.10.1.11 + + evHVACStatusBard OBJECT IDENTIFIER ::= { evHVACStatus 2 } + --1.3.6.1.4.1.3052.10.1.11.2 + + evHVACStatusBardSystem1 OBJECT IDENTIFIER ::= { evHVACStatusBard 1 } + --1.3.6.1.4.1.3052.10.1.11.2.1 + + evHVACStatusBardSystem1Stage1 OBJECT IDENTIFIER ::= { evHVACStatusBardSystem1 1 } + --1.3.6.1.4.1.3052.10.1.11.2.1.1 + + evHVACStatusBardSystem1Stage2 OBJECT IDENTIFIER ::= { evHVACStatusBardSystem1 2 } + --1.3.6.1.4.1.3052.10.1.11.2.1.2 + + evHVACStatusBardSystem2 OBJECT IDENTIFIER ::= { evHVACStatusBard 2 } + --1.3.6.1.4.1.3052.10.1.11.2.2 + + evHVACStatusBardSystem2Stage1 OBJECT IDENTIFIER ::= { evHVACStatusBardSystem2 1 } + --1.3.6.1.4.1.3052.10.1.11.2.2.1 + + evHVACStatusBardSystem2Stage2 OBJECT IDENTIFIER ::= { evHVACStatusBardSystem2 2 } + --1.3.6.1.4.1.3052.10.1.11.2.2.2 + + evHVACStatusBardTempRemote OBJECT IDENTIFIER ::= { evHVACStatusBard 5 } + --1.3.6.1.4.1.3052.10.1.11.2.5 + + evHVACStatusBardLEDs OBJECT IDENTIFIER ::= { evHVACStatusBard 7 } + --1.3.6.1.4.1.3052.10.1.11.2.7.1 + + evHVACStatusBardLEDsCooling OBJECT IDENTIFIER ::= { evHVACStatusBardLEDs 1 } + --1.3.6.1.4.1.3052.10.1.11.2.7.1 + + evHVACStatusBardLEDsHeating OBJECT IDENTIFIER ::= { evHVACStatusBardLEDs 2 } + --1.3.6.1.4.1.3052.10.1.11.2.7.2 + + evHVACStatusBardLEDsDeHumid OBJECT IDENTIFIER ::= { evHVACStatusBardLEDs 3 } + --1.3.6.1.4.1.3052.10.1.11.2.7.3 + + evHVACStatusBardAlarmStatus OBJECT IDENTIFIER ::= { evHVACStatusBard 10 } + --1.3.6.1.4.1.3052.10.1.11.2.10 + + evHVACStatusBardASSystem1 OBJECT IDENTIFIER ::= { evHVACStatusBardAlarmStatus 1 } + --1.3.6.1.4.1.3052.10.1.11.2.10.1 + + evHVACStatusBardASSystem2 OBJECT IDENTIFIER ::= { evHVACStatusBardAlarmStatus 2 } + --1.3.6.1.4.1.3052.10.1.11.2.10.2 + + evHVACStatusBardASTemp OBJECT IDENTIFIER ::= { evHVACStatusBardAlarmStatus 4 } + --1.3.6.1.4.1.3052.10.1.11.2.10.4 + + evHVACStatusAsentria OBJECT IDENTIFIER ::= { evHVACStatus 3 } + --1.3.6.1.4.1.3052.10.1.11.3 + + evHVACStatusAsentriaTemp OBJECT IDENTIFIER ::= { evHVACStatusAsentria 5 } + --1.3.6.1.4.1.3052.10.1.11.3.5 + + evHVACStatusAsentriaHumid OBJECT IDENTIFIER ::= { evHVACStatusAsentria 6 } + --1.3.6.1.4.1.3052.10.1.11.3.6 + + evHVACStatusAirsys OBJECT IDENTIFIER ::= { evHVACStatus 4 } + --1.3.6.1.4.1.3052.10.1.11.4 + + evHVACStatusAirsysAlarm OBJECT IDENTIFIER ::= { evHVACStatusAirsys 1 } + --1.3.6.1.4.1.3052.10.1.11.4.1 + + backupBattStatus OBJECT IDENTIFIER ::= { status 12 } + --1.3.6.1.4.1.3052.10.1.12 + + liBattStatus OBJECT IDENTIFIER ::= { backupBattStatus 1 } + --1.3.6.1.4.1.3052.10.1.12.1 + config OBJECT IDENTIFIER ::= { s550 2 } + --1.3.6.1.4.1.3052.10.2 + + eventSensorBasics OBJECT IDENTIFIER ::= { config 1 } + --1.3.6.1.4.1.3052.10.2.1 + + eventSensorPointConfig OBJECT IDENTIFIER ::= { config 2 } + --1.3.6.1.4.1.3052.10.2.2 + + serialPorts OBJECT IDENTIFIER ::= { config 3 } + --1.3.6.1.4.1.3052.10.2.3 + + network OBJECT IDENTIFIER ::= { config 4 } + --1.3.6.1.4.1.3052.10.2.4 + + interface OBJECT IDENTIFIER ::= { network 1 } + --1.3.6.1.4.1.3052.10.2.4 + + ethernet OBJECT IDENTIFIER ::= { interface 1 } + --1.3.6.1.4.1.3052.10.2.4.1 + + ethernet1 OBJECT IDENTIFIER ::= { ethernet 1 } + --1.3.6.1.4.1.3052.10.2.4.1.1 + + eth1VLAN OBJECT IDENTIFIER ::= { ethernet1 5 } + --1.3.6.1.4.1.3052.10.2.4.1.1.5 + + eth1VLAN1 OBJECT IDENTIFIER ::= { eth1VLAN 1 } + --1.3.6.1.4.1.3052.10.2.4.1.1.5.1 + + eth1VLAN2 OBJECT IDENTIFIER ::= { eth1VLAN 2 } + --1.3.6.1.4.1.3052.10.2.4.1.1.5.2 + + eth1VLAN3 OBJECT IDENTIFIER ::= { eth1VLAN 3 } + --1.3.6.1.4.1.3052.10.2.4.1.1.5.3 + + eth1VLAN4 OBJECT IDENTIFIER ::= { eth1VLAN 4 } + --1.3.6.1.4.1.3052.10.2.4.1.1.5.4 + + eth1VLAN5 OBJECT IDENTIFIER ::= { eth1VLAN 5 } + --1.3.6.1.4.1.3052.10.2.4.1.1.5.5 + + eth1VLAN6 OBJECT IDENTIFIER ::= { eth1VLAN 6 } + --1.3.6.1.4.1.3052.10.2.4.1.1.5.6 + + eth1IPv6 OBJECT IDENTIFIER ::= { ethernet1 7 } + --1.3.6.1.4.1.3052.10.2.4.1.1.7 + + eth1IPv6Static OBJECT IDENTIFIER ::= { eth1IPv6 2 } + --1.3.6.1.4.1.3052.10.2.4.1.1.7.2 + + eth1IPv6Auto OBJECT IDENTIFIER ::= { eth1IPv6 3 } + --1.3.6.1.4.1.3052.10.2.4.1.1.7.3 + + ethernet2 OBJECT IDENTIFIER ::= { ethernet 2 } + --1.3.6.1.4.1.3052.10.2.4.1.2 + + eth2VLAN OBJECT IDENTIFIER ::= { ethernet2 5 } + --1.3.6.1.4.1.3052.10.2.4.1.2.5 + + eth2VLAN1 OBJECT IDENTIFIER ::= { eth2VLAN 1 } + --1.3.6.1.4.1.3052.10.2.4.1.2.5.1 + + eth2VLAN2 OBJECT IDENTIFIER ::= { eth2VLAN 2 } + --1.3.6.1.4.1.3052.10.2.4.1.2.5.2 + + eth2VLAN3 OBJECT IDENTIFIER ::= { eth2VLAN 3 } + --1.3.6.1.4.1.3052.10.2.4.1.2.5.3 + + eth2VLAN4 OBJECT IDENTIFIER ::= { eth2VLAN 4 } + --1.3.6.1.4.1.3052.10.2.4.1.2.5.4 + + eth2VLAN5 OBJECT IDENTIFIER ::= { eth2VLAN 5 } + --1.3.6.1.4.1.3052.10.2.4.1.2.5.5 + + eth2VLAN6 OBJECT IDENTIFIER ::= { eth2VLAN 6 } + --1.3.6.1.4.1.3052.10.2.4.1.2.5.6 + + eth2IPv6 OBJECT IDENTIFIER ::= { ethernet2 7 } + --1.3.6.1.4.1.3052.10.2.4.1.2.7 + + eth2IPv6Static OBJECT IDENTIFIER ::= { eth2IPv6 2 } + --1.3.6.1.4.1.3052.10.2.4.1.2.7.2 + + eth2IPv6Auto OBJECT IDENTIFIER ::= { eth2IPv6 3 } + --1.3.6.1.4.1.3052.10.2.4.1.2.7.3 + + snmp OBJECT IDENTIFIER ::= { network 8 } + --1.3.6.1.4.1.3052.10.2.4.8 + + snmpNotificationTx OBJECT IDENTIFIER ::= { snmp 7 } + --1.3.6.1.4.1.3052.10.2.4.8.7 + + snmpProxy OBJECT IDENTIFIER ::= { snmp 8 } + --1.3.6.1.4.1.3052.10.2.4.8.8 + + snmpPoll OBJECT IDENTIFIER ::= { snmp 9 } + --1.3.6.1.4.1.3052.10.2.4.8.9 + + ftpPush OBJECT IDENTIFIER ::= { network 9 } + --1.3.6.1.4.1.3052.10.2.4.9 + + ppp OBJECT IDENTIFIER ::= { network 10 } + --1.3.6.1.4.1.3052.10.2.4.10 + + pppDial OBJECT IDENTIFIER ::= { ppp 1 } + --1.3.6.1.4.1.3052.10.2.4.10.1 + + pppHost OBJECT IDENTIFIER ::= { ppp 2 } + --1.3.6.1.4.1.3052.10.2.4.10.2 + + routing OBJECT IDENTIFIER ::= { network 11 } + --1.3.6.1.4.1.3052.10.2.4.11 + + netSecurity OBJECT IDENTIFIER ::= { network 12 } + --1.3.6.1.4.1.3052.10.2.4.12 + + ipRestriction OBJECT IDENTIFIER ::= { netSecurity 1 } + --1.3.6.1.4.1.3052.10.2.4.12.1 + + rts OBJECT IDENTIFIER ::= { network 13 } + --1.3.6.1.4.1.3052.10.2.4.13 + + rtsAlarms OBJECT IDENTIFIER ::= { rts 2 } + --1.3.6.1.4.1.3052.10.2.4.13.2 + + trap OBJECT IDENTIFIER ::= { network 14 } + --1.3.6.1.4.1.3052.10.2.4.14 + + trapInclude OBJECT IDENTIFIER ::= { trap 1} + --1.3.6.1.4.1.3052.10.2.4.14.1 + + routeTest OBJECT IDENTIFIER ::= { network 15 } + --1.3.6.1.4.1.3052.10.2.4.15 + + wireless OBJECT IDENTIFIER ::= { network 16 } + --1.3.6.1.4.1.3052.10.2.4.16 + + wirelessConnectivity OBJECT IDENTIFIER ::= { wireless 20 } + --1.3.6.1.4.1.3052.10.2.4.16.20 + + email OBJECT IDENTIFIER ::= { network 17 } + --1.3.6.1.4.1.3052.10.2.4.17 + + netAdvanced OBJECT IDENTIFIER ::= { network 18 } + --1.3.6.1.4.1.3052.10.2.4.18 + + web OBJECT IDENTIFIER ::= { network 19 } + --1.3.6.1.4.1.3052.10.2.4.19 + + webXMLProxy OBJECT IDENTIFIER ::= { web 4 } + --1.3.6.1.4.1.3052.10.2.4.19.4 + + ethExpan OBJECT IDENTIFIER ::= { network 20 } + --1.3.6.1.4.1.3052.10.2.4.20 + + ethExpanDHCP OBJECT IDENTIFIER ::= { ethExpan 6 } + --1.3.6.1.4.1.3052.10.2.4.20.6 + + ipv6 OBJECT IDENTIFIER ::= { network 21 } + --1.3.6.1.4.1.3052.10.2.4.21 + + cpe OBJECT IDENTIFIER ::= { network 22 } + --1.3.6.1.4.1.3052.10.2.4.22 + + dnp3 OBJECT IDENTIFIER ::= { network 23 } + --1.3.6.1.4.1.3052.10.2.4.23 + + dnp3General OBJECT IDENTIFIER ::= { dnp3 1 } + --1.3.6.1.4.1.3052.10.2.4.23.1 + + dnp3Outstation OBJECT IDENTIFIER ::= { dnp3 2 } + --1.3.6.1.4.1.3052.10.2.4.23.2 + + dnp3Master OBJECT IDENTIFIER ::= { dnp3 3 } + --1.3.6.1.4.1.3052.10.2.4.23.3 + + dnp3Error OBJECT IDENTIFIER ::= { dnp3 4 } + --1.3.6.1.4.1.3052.10.2.4.23.4 + + dnp3Status OBJECT IDENTIFIER ::= { dnp3 5 } + --1.3.6.1.4.1.3052.10.2.4.23.5 + + modem OBJECT IDENTIFIER ::= { config 5 } + --1.3.6.1.4.1.3052.10.2.5 + + modemClid OBJECT IDENTIFIER ::= { modem 8 } + --1.3.6.1.4.1.3052.10.2.5.7 + + time OBJECT IDENTIFIER ::= { config 8 } + --1.3.6.1.4.1.3052.10.2.8 + + console OBJECT IDENTIFIER ::= { config 10 } + --1.3.6.1.4.1.3052.10.2.10 + + unitSecurity OBJECT IDENTIFIER ::= { config 11 } + --1.3.6.1.4.1.3052.10.2.11 + + secCore OBJECT IDENTIFIER ::= { unitSecurity 1 } + --1.3.6.1.4.1.3052.10.2.11.1 + + secFactory OBJECT IDENTIFIER ::= { unitSecurity 3 } + --1.3.6.1.4.1.3052.10.2.11.3 + + secSSH OBJECT IDENTIFIER ::= { unitSecurity 4 } + --1.3.6.1.4.1.3052.10.2.11.4 + + secVPN OBJECT IDENTIFIER ::= { unitSecurity 5 } + --1.3.6.1.4.1.3052.10.2.11.5 + + event OBJECT IDENTIFIER ::= { config 12 } + --1.3.6.1.4.1.3052.10.2.12 + + evCore OBJECT IDENTIFIER ::= { event 1 } + --1.3.6.1.4.1.3052.10.2.12.1 + + evLog OBJECT IDENTIFIER ::= { evCore 3 } + --1.3.6.1.4.1.3052.10.2.12.1.3 + + evMgmt OBJECT IDENTIFIER ::= { evCore 4 } + --1.3.6.1.4.1.3052.10.2.12.1.4 + + evData OBJECT IDENTIFIER ::= { event 2 } + --1.3.6.1.4.1.3052.10.2.12.1 + + evdCore OBJECT IDENTIFIER ::= { evData 1 } + --1.3.6.1.4.1.3052.10.2.12.2.1 + + evNoData1 OBJECT IDENTIFIER ::= { event 3 } + --1.3.6.1.4.1.3052.10.2.12.3 + + evNoData2 OBJECT IDENTIFIER ::= { event 4 } + --1.3.6.1.4.1.3052.10.2.12.4 + + evSched1 OBJECT IDENTIFIER ::= { event 5 } + --1.3.6.1.4.1.3052.10.2.12.5 + + evSched2 OBJECT IDENTIFIER ::= { event 6 } + --1.3.6.1.4.1.3052.10.2.12.6 + + evNoSensor OBJECT IDENTIFIER ::= { event 9 } + --1.3.6.1.4.1.3052.10.2.12.9 + + fuelSensor OBJECT IDENTIFIER ::= { event 11 } + --1.3.6.1.4.1.3052.10.2.12.11 + + acPowerMonitor OBJECT IDENTIFIER ::= { event 12 } + --1.3.6.1.4.1.3052.10.2.12.12 + + evReset OBJECT IDENTIFIER ::= { event 16 } + --1.3.6.1.4.1.3052.10.2.12.16 + + evGlobal OBJECT IDENTIFIER ::= { event 18 } + --1.3.6.1.4.1.3052.10.2.12.18 + + evHVAC OBJECT IDENTIFIER ::= { event 19 } + --1.3.6.1.4.1.3052.10.2.12.19 + + evHVACBard OBJECT IDENTIFIER ::= { evHVAC 2 } + --1.3.6.1.4.1.3052.10.2.12.19.2 + + evHVACBardLocal OBJECT IDENTIFIER ::= { evHVACBard 1 } + --1.3.6.1.4.1.3052.10.2.12.19.2.1 + + evHVACBardAlarm OBJECT IDENTIFIER ::= { evHVACBardLocal 7 } + --1.3.6.1.4.1.3052.10.2.12.19.2.1.7 + + evHVACBardSynchronized OBJECT IDENTIFIER ::= { evHVACBard 2 } + --1.3.6.1.4.1.3052.10.2.12.19.2.2 + + evHVACBardDiff OBJECT IDENTIFIER ::= { evHVACBardSynchronized 19 } + --1.3.6.1.4.1.3052.10.2.12.19.2.2.19 + + evHVACBardTemp OBJECT IDENTIFIER ::= { evHVACBardSynchronized 32 } + --1.3.6.1.4.1.3052.10.2.12.19.2.2.32 + + evHVACAsentria OBJECT IDENTIFIER ::= { evHVAC 3 } + --1.3.6.1.4.1.3052.10.2.12.19.3 + + evHVACAsentriaAlarm OBJECT IDENTIFIER ::= { evHVACAsentria 6 } + --1.3.6.1.4.1.3052.10.2.12.19.3.6 + + evHVACAsentriaFire OBJECT IDENTIFIER ::= { evHVACAsentria 7 } + --1.3.6.1.4.1.3052.10.2.12.19.3.7 + + evHVACAsentriaTemp OBJECT IDENTIFIER ::= { evHVACAsentria 9 } + --1.3.6.1.4.1.3052.10.2.12.19.3.9 + + evHVACAsentriaHumid OBJECT IDENTIFIER ::= { evHVACAsentria 10 } + --1.3.6.1.4.1.3052.10.2.12.19.3.10 + + evHVACAirsys OBJECT IDENTIFIER ::= { evHVAC 4 } + --1.3.6.1.4.1.3052.10.2.12.19.4 + + evHVACAirsysGeneral OBJECT IDENTIFIER ::= { evHVACAirsys 1 } + --1.3.6.1.4.1.3052.10.2.12.19.4.1 + + evHVACAirsysAlarm OBJECT IDENTIFIER ::= { evHVACAirsys 2 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2 + + evHVACAirsysTemp OBJECT IDENTIFIER ::= { evHVACAirsys 3 } + --1.3.6.1.4.1.3052.10.2.12.19.4.3 + + evHVACAirsysHumid OBJECT IDENTIFIER ::= { evHVACAirsys 4 } + --1.3.6.1.4.1.3052.10.2.12.19.4.4 + + evEvps OBJECT IDENTIFIER ::= { event 20 } + --1.3.6.1.4.1.3052.10.2.12.20 + + accessControl OBJECT IDENTIFIER ::= { event 21 } + --1.3.6.1.4.1.3052.10.2.12.21 + + telemetry OBJECT IDENTIFIER ::= { event 22 } + --1.3.6.1.4.1.3052.10.2.12.22 + + siteSecurity OBJECT IDENTIFIER ::= { event 23 } + --1.3.6.1.4.1.3052.10.2.12.23 + + + action OBJECT IDENTIFIER ::= { config 14 } + --1.3.6.1.4.1.3052.10.2.14 + + actionSched OBJECT IDENTIFIER ::= { action 3 } + --1.3.6.1.4.1.3052.10.2.14.3 + + actionAsentria OBJECT IDENTIFIER ::= { action 4 } + --1.3.6.1.4.1.3052.10.2.14.4 + + sys OBJECT IDENTIFIER ::= { config 16 } + --1.3.6.1.4.1.3052.10.2.16 + + sysTime OBJECT IDENTIFIER ::= { sys 1 } + --1.3.6.1.4.1.3052.10.2.16.1 + + sysTimeNet OBJECT IDENTIFIER ::= { sysTime 4 } + --1.3.6.1.4.1.3052.10.2.16.1.4 + + sysPT OBJECT IDENTIFIER ::= { sys 2 } + --1.3.6.1.4.1.3052.10.2.16.2 + + sysTimeStamp OBJECT IDENTIFIER ::= { sys 8 } + --1.3.6.1.4.1.3052.10.2.16.8 + + sysLog OBJECT IDENTIFIER ::= { sys 9 } + --1.3.6.1.4.1.3052.10.2.16.9 + + sysCRDB OBJECT IDENTIFIER ::= { sys 10 } + --1.3.6.1.4.1.3052.10.2.16.10 + + sysLoc OBJECT IDENTIFIER ::= { sys 14 } + --1.3.6.1.4.1.3052.10.2.16.14 + + sysAssetMgmt OBJECT IDENTIFIER ::= { sys 15 } + --1.3.6.1.4.1.3052.10.2.16.15 + + sysFileTransfer OBJECT IDENTIFIER ::= { sys 17 } + --1.3.6.1.4.1.3052.10.2.16.17 + + sysUpdate OBJECT IDENTIFIER ::= { sys 18 } + --1.3.6.1.4.1.3052.10.2.16.18 + + auditLog OBJECT IDENTIFIER ::= { config 17 } + --1.3.6.1.4.1.3052.10.2.17 + + scripting OBJECT IDENTIFIER ::= { config 18 } + --1.3.6.1.4.1.3052.10.2.18 + + generator OBJECT IDENTIFIER ::= { config 19 } + --1.3.6.1.4.1.3052.10.2.19 + + genSet OBJECT IDENTIFIER ::= { generator 1 } + --1.3.6.1.4.1.3052.10.2.19.1 + + genSetRelay OBJECT IDENTIFIER ::= { genSet 2 } + --1.3.6.1.4.1.3052.10.2.19.1.2 + + genSetCC OBJECT IDENTIFIER ::= { genSet 3 } + --1.3.6.1.4.1.3052.10.2.19.1.3 + + genRun OBJECT IDENTIFIER ::= { generator 2 } + --1.3.6.1.4.1.3052.10.2.19.2 + + genRunNonstartEvent OBJECT IDENTIFIER ::= { genRun 7 } + --1.3.6.1.4.1.3052.10.2.19.2.7 + + calendar OBJECT IDENTIFIER ::= { config 20 } + --1.3.6.1.4.1.3052.10.2.20 + + productIds OBJECT IDENTIFIER ::= { s550 3 } + --1.3.6.1.4.1.3052.10.3 + +--*************************************************************************************** +--OBJECT DEFINITIONS +--*************************************************************************************** + +--*************************************************************************************** +--EventSensor Status Section 1.1 +--*************************************************************************************** + +esPointTable OBJECT-TYPE + SYNTAX SEQUENCE OF ESPoint + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + " + This table organizes 4 basic attributes of points. A point + is a particular sensor on an EventSensor (e.g., temperature, + humidity, contact closure 2, output 5, etc.). The 4 point + attributes are its name, whether it's in its event state, + the point's value as a number and its value as a string. + + Points are referenced by a point index. The point index + is a string of 3 numbers separated by periods. + It contains all the information necessary for getting a piece + of data off an event sensor; namely, which EventSensor, + point class, and which-sensor-of-that-class (a.k.a. point). + " + ::= { eventSensorStatus 1 } + --1.3.6.1.4.1.3052.10.1.1.1 + +esPointEntry OBJECT-TYPE + SYNTAX ESPoint + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry for EventSensor point table" + INDEX { esIndexES, esIndexPC, esIndexPoint } + ::= { esPointTable 1 } + --1.3.6.1.4.1.3052.10.1.1.1.1 + +esIndexES OBJECT-TYPE + SYNTAX Integer32 (1..200) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The part of the point index that refers to an + EventSensor. + + The point index is a string of 3 numbers separated + by periods. It contains all the information + necessary for getting a piece of data off an event + sensor; namely, which EventSensor, point class, + and which-sensor-of-that-class (a.k.a. point). + + This object's allowable values are 1 through 16, + and 200. 200 always refers to the EventSensor + inside the unit. 1 through 16 refer to additional + attached EventSensors. + + The number corresponding to an EventSensor is + determined by the user at the initial configuration + time. If there is an internal sensor in the unit, + it will always be the first item in the Sensor + Events setup menu. + + For example, if a new EventSensor is configured as + the 2nd entry AFTER the internal EventSensor (if + one exists) in the Sensor Events Setup Menu, then + that EventSensor will be known from then on as + EventSensor 2. All point indeces with esIndexES=2 + will now refer to that particular EventSensor. + " + ::= { esPointEntry 1 } + --1.3.6.1.4.1.3052.10.1.1.1.1.1 + +esIndexPC OBJECT-TYPE + SYNTAX Integer32 (1..6) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The part of the point index that refers to point class. + + The point index is a string of 3 numbers separated by periods. + It contains all the information necessary for getting a piece + of data off an event sensor; namely, which EventSensor, + point class, and which-sensor-of-that-class (a.k.a. point). + + The values for this object are: + 1=temperature sensor + 2=contact closure + 3=humidity sensor + 4=noise sensor + 5=analog input + 6=output (relay output or power output) + " + ::= { esPointEntry 2 } + --1.3.6.1.4.1.3052.10.1.1.1.1.2 + +esIndexPoint OBJECT-TYPE + SYNTAX Integer32 (1..64) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The part of the point index that delineates which + sensor on the EventSensor. + + So this combined with esIndexPC (Point Class or type) + and esIndexES (which EventSensor) uniquely defines each + point (sensor or output) attached to a unit. For + example, if esIndexES is 3, esIndexPC is 1 and + esIndexPoint is 4 then this is the Fourth Temperature + Sensor on EventSensor number 3." + ::= { esPointEntry 3 } + --1.3.6.1.4.1.3052.10.1.1.1.1.3 + +esPointName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The name of the point on an EventSensor. For example, + 'AC temp' (in the case of the temperature sensor on an + EventSensor). + + There can be multiple points of the same point class on an + EventSensor (e.g., 8 contact closures) and multiple sensor + classes on an EventSensor (e.g., temperature, contact closure, + humidity). + + If the point referenced by a given point index is solitary + (e.g., temperature sensor, because there can be only one on + an EventSensor), then this object reads as '<EventSensor + name>'. Setting this object for solitary point indices sets + the EventSensor name only. + + On the other hand, if a given point is among other points of + the same point class on an EventSensor, then this object reads + as '<Sensor name>'. Setting this object for these NON- + solitary point indices sets the sensor name only - not the + EventSensor name." + ::= { esPointEntry 4 } + --1.3.6.1.4.1.3052.10.1.1.1.1.4 + +esPointInEventState OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "A number referring to the event state of a point + on an EventSensor. This number can have different + meanings depending on the point class. + + If the point class is temperature, humidity, or + analog input, then the values of this object are: + 1=very low + 2=low + 3=normal + 4=high + 5=very high + + For contact closures the values of this object are: + 1=point in event state + 2=point in normal state + + For outputs the values of this object is the numeric + code for the logical state of the output: 1 or 2. The + logical state of the output is either active/inactive for + relay outputs or on/off for power outputs. The logical + state of the output has different nomenclature depending + on the type of the output (relay output or power output): + + 1=active (for relay output) or on (for power output) + 2=inactive (for relay output) or off (for power output) + + This is not necessarily representative of physical state + of the output. Physical state is energized/de-energized, + for both relay and power outputs. For relay outputs, + the active logical state corresponds to either the energized + physical state or the de-energized physical state depending + on how the relay output is configured. For power outputs, + the on logical state always corresponds to the energized + physical state. + + For any point class and any point, if the event + state is undefined, then the value of this object + is 0. + + For any point class except output, this object is read-only. + For outputs, setting this object to 1 puts the output into + its active logical state. + + Setting this object to 2 puts the output into its inactive + logical state. + + Setting this object to any value greater than 2 puts the + output into its active logical state for that many seconds + (up to 3600), after which time it puts the output into its + inactive logical state. + " + ::= { esPointEntry 5 } + --1.3.6.1.4.1.3052.10.1.1.1.1.5 + +esPointValueInt OBJECT-TYPE + SYNTAX Integer32 (-2147483648..2147483647) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "A read-only number referring to the value of a + point on an EventSensor. + + If the point class is temperature, then this object + is the temperature in its configured scale (default + is Fahrenheit). + + If the point class is contact closure, then + this object is either 0 (open) or 1 (closed). + + If the point class is humidity, then this object + is the percent relative humidity. + + If the point class is analog input, then this + object is the signed input value in tenths of the + configured units. + + If the point class is an output, then this object is + the numeric code for the physical state of the output. + 0=de-energized + 1=energized + + This object cannot be used to control the output, i.e, + change its logical or physical state (instead use + the esPointInEventState object). + " + ::= { esPointEntry 6 } + --1.3.6.1.4.1.3052.10.1.1.1.1.6 + +esPointValueStr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A string referring to the value of a point on an + EventSensor. + + For contact closures this object is either 'Open' + or 'Closed'. + + For outputs this object is a concatenation of the + logical state and physical state, separated by '/'. + + For a relay output this object can be one of the + following 4 possible values: + + Active/Energized + Inactive/Energized + Active/De-energized + Inactve/De-energized + + For a power output this object can be one of the + following 2 possible values: + + On/Energized + Off/De-energized + + For temperature and humidity point classes, this + object is the string representation of the + esPointValueInt object. For temperature, 'C' or + 'F' is including in the string to indicate scale. + + For analog inputs, this object is the string + representation of the plus/minus input in the + configured units appended with the unit name. + " + ::= { esPointEntry 7 } + --1.3.6.1.4.1.3052.10.1.1.1.1.7 + +esPointTimeLastChange OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The time of the last time an event was + triggerred for a point on an EventSensor in + MM/DD/YY HH:MM:SS format. + + For contact closures, the possible events are + Active and Inactive. For temperature, humidity, + and analog inputs, the possible events are Normal, + High, Very High, Low, and Very Low. + + For outputs, this object is a null string." + ::= { esPointEntry 8 } + --1.3.6.1.4.1.3052.10.1.1.1.1.8 + +esPointTimetickLastChange OBJECT-TYPE + SYNTAX TimeTicks + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The time of the last time an event was + triggerred for a point on an EventSensor in + 100ths of seconds since reset. + + For contact closures, the possible events are + Active and Inactive. For temperature, humidity, + and analog inputs, the possible events are Normal, + High, Very High, Low, and Very Low. + + For outputs, this object is 0." + ::= { esPointEntry 9 } + --1.3.6.1.4.1.3052.10.1.1.1.1.9 + +esPointAliasValueStr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "For CC inputs, this is the CC active/inactive alias setting + setting value that currently corresponds to the event state. + So if the CC input is in the event state, then this object + is the active alias setting value. If the CC input is in the + normal state, then this object is the inactive alias setting + value. + + For relay/power outputs, this is the output active/inactive + alias setting value that currently corresponds to the output + state. So if the output is in the active state, then this + object is the active alias setting value. If the output is + in hte inactive state, then this object is the inactive alias + setting value. + + For non-CC and non-output sensors, this is the same as the + esPointValueStr object." + ::= { esPointEntry 10 } + --1.3.6.1.4.1.3052.10.1.1.1.1.10 + + + +esPointClassValueStr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "For CC inputs, this is the CC active/inactive class setting + setting value that currently corresponds to the event state. + So if the CC input is in the event state, then this object + is the active class setting value. If the CC input is in the + normal state, then this object is the inactive class setting + value. + + For relay/power, analog and temp outputs, this is the output + class string given the event (Very High, High, Normal, Low and + Very Low). The class string is based upon the chosen string in + the class table for e.g. Info, Minor, Major, Minor, Critical etc. + If the given event is High, the chosen Class string for this event + is what returned. + " + ::= { esPointEntry 11 } + --1.3.6.1.4.1.3052.10.1.1.1.1.11 + +--*************************************************************************************** +--Data Event Status Section 1.2 +--*************************************************************************************** + +deStatusTable OBJECT-TYPE + SYNTAX SEQUENCE OF DEStatus + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Data Event Status Table" + ::= { dataEventStatus 1 } + --1.3.6.1.4.1.3052.10.1.2.1 + +deStatusEntry OBJECT-TYPE + SYNTAX DEStatus + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "EventSensor status entry" + INDEX { deStatusIndex } + ::= { deStatusTable 1 } + --1.3.6.1.4.1.3052.10.1.2.1.1 + +deStatusIndex OBJECT-TYPE + SYNTAX Integer32 (1..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Index for Data Events" + ::= { deStatusEntry 1 } + --1.3.6.1.4.1.3052.10.1.2.1.1.1 + +deStatusName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Data Event name" + ::= { deStatusEntry 2 } + --1.3.6.1.4.1.3052.10.1.2.1.1.2 + +deStatusCounter OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of times a data record has matched this + event's equation. + Range: 1-999999999" + ::= { deStatusEntry 3 } + --1.3.6.1.4.1.3052.10.1.2.1.1.3 + +deStatusThreshold OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of times the equation is matched before + an event is triggered. + Range: 1-999999999" + ::= { deStatusEntry 4 } + --1.3.6.1.4.1.3052.10.1.2.1.1.4 + +modemStatus OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "status of modem (idle, dialing, connected, etc.)" + ::= { status 3 } + --1.3.6.1.4.1.3052.10.1.3 + +modemCLIDLogTable OBJECT-TYPE + SYNTAX SEQUENCE OF ModemCLIDLogConfig + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table of numbers of recent dialing parties" + ::= { status 4 } + --1.3.6.1.4.1.3052.10.1.4 + +modemCLIDLogEntry OBJECT-TYPE + SYNTAX ModemCLIDLogConfig + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry for table of CLID log entries" + INDEX { modemCLIDLogIndex } + ::= { modemCLIDLogTable 1 } + --1.3.6.1.4.1.3052.10.1.4.1 + +modemCLIDLogIndex OBJECT-TYPE + SYNTAX Integer32 (1..8) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Index for table of CLID log entries" + ::= { modemCLIDLogEntry 1 } + --1.3.6.1.4.1.3052.10.1.4.1.1 + +modemCLIDLogNumber OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "recently logged number of dialing party" + ::= { modemCLIDLogEntry 2 } + --1.3.6.1.4.1.3052.10.1.4.1.2 + +--*************************************************************************************** +--Power Distribution Status Section 1.5 +--*************************************************************************************** + +pdConfig OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Power Distribution output configuration" + ::= { powerDistributionStatus 1 } + --1.3.6.1.4.1.3052.10.1.5.1 + +PowerDistribNextGen ::= + SEQUENCE { + pdnIndexPD + Integer32, + pdnIndexOutput + Integer32, + pdnConfig + DisplayString, + pdnMainCurrentInEventState + DisplayString, + pdnMainCurrentValue + Integer32, + pdnMainCurrentValueStr + DisplayString, + pdnMainCurrentDeadband + Integer32, + pdnMainCurrentVHighCurrent + Integer32, + pdnMainCurrentHighCurrent + Integer32, + pdnMainCurrentLowCurrent + Integer32, + pdnMainCurrentVLowCurrent + Integer32, + pdnMainVoltageInEventState + DisplayString, + pdnMainVoltageValue + Integer32, + pdnMainVoltageValueStr + DisplayString, + pdnMainVoltageDeadband + Integer32, + pdnMainVoltageVHighVoltage + Integer32, + pdnMainVoltageHighVoltage + Integer32, + pdnMainVoltageLowVoltage + Integer32, + pdnMainVoltageVLowVoltage + Integer32, + pdnMainPowerValue + Integer32, + pdnMainPowerValueStr + DisplayString, + pdnOutputCurrentInEventState + DisplayString, + pdnOutputCurrentValue + Integer32, + pdnOutputCurrentValueStr + DisplayString, + pdnOutputCurrentDeadband + Integer32, + pdnOutputCurrentVHighCurrent + Integer32, + pdnOutputCurrentHighCurrent + Integer32, + pdnOutputCurrentLowCurrent + Integer32, + pdnOutputCurrentVLowCurrent + Integer32, + pdnOutputFuseInEventState + DisplayString, + pdnOutputFuseValueStr + DisplayString, + pdnMainCombinedStatus + DisplayString, + pdnOutputCombinedStatusBlock1 + DisplayString, + pdnOutputCombinedStatusBlock2 + DisplayString, + pdnDeviceCurrentValue + Integer32, + pdnDeviceCurrentValueStr + DisplayString +} + +pdnTable OBJECT-TYPE + SYNTAX SEQUENCE OF PowerDistribNextGen + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table of power distribution objects arranged according + to next-generation methodology (i.e., using multiple PowerBoss + power distributors in addition to the on-board power + distributor)." + ::= { pdNextGen 1 } + --1.3.6.1.4.1.3052.10.1.5.4.1 + +pdnEntry OBJECT-TYPE + SYNTAX PowerDistribNextGen + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry for table of power distribution objects arranged according + to next-generation methodology (i.e., using multiple PowerBoss + power distributors in addition to the on-board power + distributor)." + INDEX { pdnIndexPD, pdnIndexOutput } + ::= { pdnTable 1 } + --1.3.6.1.4.1.3052.10.1.5.4.1.1 + +pdnIndexPD OBJECT-TYPE + SYNTAX Integer32 (1..200) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Index for table of power distribution objects, specifically the + index that refers to which power distributor. A value of 200 means + the internal power distributor. A value from 1 to 16 refers to an + external power distributor (PowerBoss), and is the same value as esIndexES, + which refers to the PowerBoss as an EventSensor in the eventSensorStatus + object table. In other words, pdnIndexPD is the same as esIndexES: + esIndexES is used to refer to the PowerBoss as an eventsensor (i.e., control + outputs), while pdnIndexPD is used to refer to the PowerBoss when used for + power distribution monitoring (i.e., to alarm on output + current/voltage/fuse status)." + ::= { pdnEntry 1 } + --1.3.6.1.4.1.3052.10.1.5.4.1.1.1 + +pdnIndexOutput OBJECT-TYPE + SYNTAX Integer32 (1..12) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Index for table of power distribution objects, specifically the + index that refers to which output on the power distributor specified + by pdnIndexPD. For objects where the output is irrelevant, this index + should be 1." + ::= { pdnEntry 2 } + --1.3.6.1.4.1.3052.10.1.5.4.1.1.2 + +pdnConfig OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of outputs on the power distributor specified by pdnIndexPD. + pdnIndexOutput should be 1 for this object." + ::= { pdnEntry 3 } + --1.3.6.1.4.1.3052.10.1.5.4.1.1.3 + +pdnMainCurrentInEventState OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The event state of the current (i.e. Amps) event of the power distributor + specified by pdnIndexPD. pdnIndexOutput should be 1 for this object. + Possible values for this object are: 'Very Low', 'Low', 'Normal', 'High', + 'Very High'." + ::= { pdnEntry 4 } + --1.3.6.1.4.1.3052.10.1.5.4.1.1.4 + +pdnMainCurrentValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current drawn, in mA, for the power distributor specified by pdnIndexPD. + If pdnIndexPD is 1-16 then this is an external power distributor (PowerBoss) + and refers to the current drawn by that PowerBoss and all equipment powered + by that PowerBoss. pdnIndexOutput should be 1 for this object." + ::= { pdnEntry 5 } + --1.3.6.1.4.1.3052.10.1.5.4.1.1.5 + +pdnMainCurrentValueStr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Essentially pdnMainCurrentValue formatted as a string in units of Amps, with + 3 decimal places. pdnIndexOutput should be 1 for this object." + ::= { pdnEntry 6 } + --1.3.6.1.4.1.3052.10.1.5.4.1.1.6 + +pdnMainCurrentDeadband OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The deadband, in mA, for the main current sensor for the power distributor + specified by pdIndexPD. pdnIndexOutput should be 1 for this object." + ::= { pdnEntry 7 } + --1.3.6.1.4.1.3052.10.1.5.4.1.1.7 + +pdnMainCurrentVHighCurrent OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current, in mA, for the main current sensor's Very High event threshold, + for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1 + for this object." + ::= { pdnEntry 8 } + --1.3.6.1.4.1.3052.10.1.5.4.1.1.8 + +pdnMainCurrentHighCurrent OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current, in mA, for the main current sensor's High event threshold, + for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1 + for this object." + ::= { pdnEntry 9 } + --1.3.6.1.4.1.3052.10.1.5.4.1.1.9 + +pdnMainCurrentLowCurrent OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current, in mA, for the main current sensor's Low event threshold, + for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1 + for this object." + ::= { pdnEntry 10 } + --1.3.6.1.4.1.3052.10.1.5.4.1.1.10 + +pdnMainCurrentVLowCurrent OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current, in mA, for the main current sensor's Very Low event threshold, + for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1 + for this object." + ::= { pdnEntry 11 } + --1.3.6.1.4.1.3052.10.1.5.4.1.1.11 + +pdnMainVoltageInEventState OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The event state of the voltage event of the power distributor + specified by pdnIndexPD. pdnIndexOutput should be 1 for this object. + Possible values for this object are: 'Very Low', 'Low', 'Normal', 'High', + 'Very High'." + ::= { pdnEntry 12 } + --1.3.6.1.4.1.3052.10.1.5.4.1.1.12 + +pdnMainVoltageValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The voltage, in mV, at the power distributor specified by pdnIndexPD. + If pdnIndexPD is 1-16 then this is an external power distributor (PowerBoss) + and refers to the voltage at that PowerBoss and all equipment powered by that + PowerBoss. pdnIndexOutput should be 1 for this object." + ::= { pdnEntry 13 } + --1.3.6.1.4.1.3052.10.1.5.4.1.1.13 + +pdnMainVoltageValueStr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Essentially pdnMainVoltageValue formatted as a string in units of Volts, with + 3 decimal places. pdnIndexOutput should be 1 for this object." + ::= { pdnEntry 14 } + --1.3.6.1.4.1.3052.10.1.5.4.1.1.14 + +pdnMainVoltageDeadband OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The deadband, in mV, for the main voltage sensor for the power distributor + specified by pdIndexPD. pdnIndexOutput should be 1 for this object." + ::= { pdnEntry 15 } + --1.3.6.1.4.1.3052.10.1.5.4.1.1.15 + +pdnMainVoltageVHighVoltage OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The voltage, in mA, for the main voltage sensor's Very High event threshold, + for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1 + for this object." + ::= { pdnEntry 16 } + --1.3.6.1.4.1.3052.10.1.5.4.1.1.16 + +pdnMainVoltageHighVoltage OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The voltage, in mV, for the main voltage sensor's High event threshold, + for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1 + for this object." + ::= { pdnEntry 17 } + --1.3.6.1.4.1.3052.10.1.5.4.1.1.17 + +pdnMainVoltageLowVoltage OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The voltage, in mV, for the main voltage sensor's Low event threshold, + for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1 + for this object." + ::= { pdnEntry 18 } + --1.3.6.1.4.1.3052.10.1.5.4.1.1.18 + +pdnMainVoltageVLowVoltage OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The voltage, in mV, for the main voltage sensor's Very Low event threshold, + for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1 + for this object." + ::= { pdnEntry 19 } + --1.3.6.1.4.1.3052.10.1.5.4.1.1.19 + +pdnMainPowerValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The power, in Watts, for the power distributor specified by pdIndexPD. + pdnIndexOutput should be 1 for this object." + ::= { pdnEntry 20 } + --1.3.6.1.4.1.3052.10.1.5.4.1.1.20 + +pdnMainPowerValueStr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The power, in Watts, for the power distributor specified by pdIndexPD, + formatted as a string with the unit name 'Watts'. pdnIndexOutput should be 1 + for this object." + ::= { pdnEntry 21 } + --1.3.6.1.4.1.3052.10.1.5.4.1.1.21 + +pdnOutputCurrentInEventState OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The event state of the current (i.e. Amps) event of the power distributor + output specified by pdnIndexPD and pdnIndexOutput. E.g., for pdnIndexPD=200 + and pdnIndexOutput=2, this refers to power output #2 of the internal power + distributor. Possible values for this object are: 'Very Low', 'Low', 'Normal', + 'High', 'Very High'." + ::= { pdnEntry 22 } + --1.3.6.1.4.1.3052.10.1.5.4.1.1.22 + +pdnOutputCurrentValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current drawn, in mA, for the power distributor output specified by + pdnIndexPD and pdIndexOutput. E.g., if pdIndexPD is 3 then this is an external + power distributor (PowerBoss) identified as 'power distributor 3' and refers to + the current drawn by a specific power output on that PowerBoss. The specific + power output is specified by pdIndexOutput." + ::= { pdnEntry 23 } + --1.3.6.1.4.1.3052.10.1.5.4.1.1.23 + +pdnOutputCurrentValueStr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Essentially pdnOutputCurrentValue formatted as a string in units of Amps, with + 3 decimal places." + ::= { pdnEntry 24 } + --1.3.6.1.4.1.3052.10.1.5.4.1.1.24 + +pdnOutputCurrentDeadband OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The deadband, in mA, for the main current sensor for the power distributor + specified by pdIndexPD. The power output is specified by pdnIndexOutput." + ::= { pdnEntry 25 } + --1.3.6.1.4.1.3052.10.1.5.4.1.1.25 + +pdnOutputCurrentVHighCurrent OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current, in mA, for a specific power output's current sensor Very High + event threshold, for the power distributor specified by pdIndexPD. The power + output is specified by pdnIndexOutput." + ::= { pdnEntry 26 } + --1.3.6.1.4.1.3052.10.1.5.4.1.1.26 + +pdnOutputCurrentHighCurrent OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current, in mA, for a specific power output's current sensor High event + threshold, for the power distributor specified by pdIndexPD. The power output + is specified by pdnIndexOutput for this object." + ::= { pdnEntry 27 } + --1.3.6.1.4.1.3052.10.1.5.4.1.1.27 + +pdnOutputCurrentLowCurrent OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current, in mA, for a specific power output's current sensor Low event + threshold, for the power distributor specified by pdIndexPD. The power output + is specified by pdnIndexOutput for this object." + ::= { pdnEntry 28 } + --1.3.6.1.4.1.3052.10.1.5.4.1.1.28 + +pdnOutputCurrentVLowCurrent OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current, in mA, for a specific power output's current sensor Very Low + event threshold, for the power distributor specified by pdIndexPD. The power + output is specified by pdnIndexOutput for this object." + ::= { pdnEntry 29 } + --1.3.6.1.4.1.3052.10.1.5.4.1.1.29 + +pdnOutputFuseInEventState OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The event state of the fuse event of the power distributor output specified + by pdnIndexPD and pdnIndexOutput. E.g., for pdnIndexPD=14 and pdnIndexOutput=2, + this refers to power output #2 of the external power distributor (PowerBoss), + identified as 'power distributor 14'. Possible values for this object are: + 'Very Low', 'Low', 'Normal', 'High', 'Very High'. This object exists only for + power distributors with fuse monitoring support." + ::= { pdnEntry 30 } + --1.3.6.1.4.1.3052.10.1.5.4.1.1.30 + +pdnOutputFuseValueStr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The state of the fuse of the power distributor output specified + by pdnIndexPD and pdnIndexOutput. Possible values for this object are: + 'BLOWN' and 'OK'. This object exists only for power distributors with fuse + monitoring support." + ::= { pdnEntry 31 } + --1.3.6.1.4.1.3052.10.1.5.4.1.1.31 + +pdnMainCombinedStatus OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Combined status string intended to be parsed by NMS: + format: voltageColorCode`voltageEventState`voltageValue`mainCurrentColorCode`mainCurrentEventState`mainCurrentValue`deviceCurrentValue`mainPowerValue" + ::= { pdnEntry 32 } + --1.3.6.1.4.1.3052.10.1.5.4.1.1.32 + +pdnOutputCombinedStatusBlock1 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Combined status string intended to be parsed by NMS: + format: numInBlock~outputCurrentColorCode1`outputCurrentEventState1`outputCurrentValue1`fuseColorCode1`fuseValue1~..." + ::= { pdnEntry 33 } + --1.3.6.1.4.1.3052.10.1.5.4.1.1.33 + +pdnOutputCombinedStatusBlock2 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Combined status string intended to be parsed by NMS: + format: numInBlock~outputCurrentColorCode1`outputCurrentEventState1`outputCurrentValue1`fuseColorCode1`fuseValue1~..." + ::= { pdnEntry 34 } + --1.3.6.1.4.1.3052.10.1.5.4.1.1.34 + +pdnDeviceCurrentValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current drawn by device in mA. For the internal power distributor device, + this is the current drawn by the SiteBoss 571. For an external power + distributor device (PowerBoss), this is the current drawn by the + PowerBoss. This object exists only for power distributors with device + current monitoring support." + ::= { pdnEntry 35 } + --1.3.6.1.4.1.3052.10.1.5.4.1.1.35 + +pdnDeviceCurrentValueStr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current drawn by device as a string with units (Amps). For the internal + power distributor device, this is the current drawn by the SiteBoss 571. + For an external power distributor device (PowerBoss), this is the + current drawn by the PowerBoss. This object exists only for power + distributors with device current monitoring support." + ::= { pdnEntry 36 } + --1.3.6.1.4.1.3052.10.1.5.4.1.1.36 + +pdSystemCurrent OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Total current drawn by all power distributors in system; that is, the + sum of all pdnMainCurrentValue objects for all connected power + distributors: internal and external." + ::= { pdSystem 1 } + --1.3.6.1.4.1.3052.10.1.5.5.1 + +pdSystemPower OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Total power used by all power distributors in system; that is, the + sum of all pdnMainPowerValue objects for all connected power + distributors: internal and external." + ::= { pdSystem 2 } + --1.3.6.1.4.1.3052.10.1.5.5.2 + + +--*************************************************************************************** +--Fuel Sensor 1.6 +--*************************************************************************************** + +fsStatusTable OBJECT-TYPE + SYNTAX SEQUENCE OF FSStatus + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Fuel sensor status table" + ::= { fuelSensorStatus 1 } + --1.3.6.1.4.1.3052.10.1.6.1 + +fsStatusEntry OBJECT-TYPE + SYNTAX FSStatus + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Fuel sensor status table entry" + INDEX { fsStatusIndex } + ::= { fsStatusTable 1 } + --1.3.6.1.4.1.3052.10.1.6.1.1 + +fsStatusIndex OBJECT-TYPE + SYNTAX Integer32 (1..3) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Index for fuel sensors" + ::= { fsStatusEntry 1 } + --1.3.6.1.4.1.3052.10.1.6.1.1.1 + +fsStatusName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Fuel sensor name" + ::= { fsStatusEntry 2 } + --1.3.6.1.4.1.3052.10.1.6.1.1.2 + +fsStatusDeviceState OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Fuel sensor device state" + ::= { fsStatusEntry 3 } + --1.3.6.1.4.1.3052.10.1.6.1.1.3 + +fsStatusVolumeValueString OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Fuel volume. Range is -2,147,483,648 to 2,147,483,647. This value reads + -999 when the fuel sensor is disconnected" + ::= { fsStatusEntry 4 } + --1.3.6.1.4.1.3052.10.1.6.1.1.4 + +fsStatusVolumePercentLevel OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Height of the fluid in the tank expressed as a percentage of the tank + height, in hundredths of a percent." + ::= { fsStatusEntry 7 } + --1.3.6.1.4.1.3052.10.1.6.1.1.7 + +fsStatusVolumeInEventState OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current event status of the fuel sensor." + ::= { fsStatusEntry 8 } + --1.3.6.1.4.1.3052.10.1.6.1.1.8 + +fsStatusCombined OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Combined status string intended to be parsed by NMS: + deviceState`deviceStateColorCode`percentRounded`valueAsFloat`volumeEventState`volumeEventStateColorCode`capacity`units`name" + ::= { fsStatusEntry 9 } + --1.3.6.1.4.1.3052.10.1.6.1.1.9 + +--*************************************************************************************** +--Wireless Modem Status Section 1.7 +--*************************************************************************************** + +wmsStatus OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Wireless modem status" + ::= { wirelessModemStatus 1 } + --1.3.6.1.4.1.3052.10.1.7.1 + +wmsSignal OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Wireless modem Signal strength" + ::= { wirelessModemStatus 2 } + --1.3.6.1.4.1.3052.10.1.7.2 + +wmsRSSI OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Wireless modem Signal strength (RSSI)" + ::= { wirelessModemStatus 3 } + --1.3.6.1.4.1.3052.10.1.7.3 + +wmsBER OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Wireless modem Bit Error Rate" + ::= { wirelessModemStatus 4 } + --1.3.6.1.4.1.3052.10.1.7.4 + +wmsUpdated OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Wireless modem info last update time" + ::= { wirelessModemStatus 5 } + --1.3.6.1.4.1.3052.10.1.7.5 + +wmsRegistration OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Wireless modem registration status" + ::= { wirelessModemStatus 6 } + --1.3.6.1.4.1.3052.10.1.7.6 + +wmsLAC OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Wireless modem Location Area Code" + ::= { wirelessModemStatus 7 } + --1.3.6.1.4.1.3052.10.1.7.7 + +wmsCellID OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Wireless modem Cell ID" + ::= { wirelessModemStatus 8 } + --1.3.6.1.4.1.3052.10.1.7.8 + +wmsIMSI OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Wireless modem Internation Mobile Subscriber Identity number" + ::= { wirelessModemStatus 9 } + --1.3.6.1.4.1.3052.10.1.7.9 + +wmsPhnum OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Wireless modem phone number" + ::= { wirelessModemStatus 10 } + --1.3.6.1.4.1.3052.10.1.7.10 + +wmsLocalIP OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Local IP address of modem on wireless network" + ::= { wirelessModemStatus 11 } + --1.3.6.1.4.1.3052.10.1.7.11 + +wmsMgfID OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Wireless modem manufacturer ID" + ::= { wirelessModemStatus 12 } + --1.3.6.1.4.1.3052.10.1.7.12 + +wmsModelID OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Wireless modem model ID" + ::= { wirelessModemStatus 13 } + --1.3.6.1.4.1.3052.10.1.7.13 + +wmsIMEI OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Wireless modem International Mobile Equipment Identity number" + ::= { wirelessModemStatus 14 } + --1.3.6.1.4.1.3052.10.1.7.14 + +wmsRevID OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Wireless modem revision ID" + ::= { wirelessModemStatus 15 } + --1.3.6.1.4.1.3052.10.1.7.15 + +wmsNetName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Wireless modem network name" + ::= { wirelessModemStatus 16 } + --1.3.6.1.4.1.3052.10.1.7.16 + +wmsGPRSStatus OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Wireless modem (E)GPRS status" + ::= { wirelessModemStatus 17 } + --1.3.6.1.4.1.3052.10.1.7.17 + +wmsBand OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Wireless modem band" + ::= { wirelessModemStatus 18 } + --1.3.6.1.4.1.3052.10.1.7.18 + +wmsChannel OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Wireless modem channel" + ::= { wirelessModemStatus 19 } + --1.3.6.1.4.1.3052.10.1.7.19 + +wmsCountryCode OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Wireless modem country code" + ::= { wirelessModemStatus 20 } + --1.3.6.1.4.1.3052.10.1.7.20 + +wmsNetCode OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Wireless modem network code" + ::= { wirelessModemStatus 21 } + --1.3.6.1.4.1.3052.10.1.7.21 + +wmsPLMNColor OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Wireless modem PLMN color" + ::= { wirelessModemStatus 22 } + --1.3.6.1.4.1.3052.10.1.7.22 + +wmsBScolor OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Wireless modem BS color" + ::= { wirelessModemStatus 23 } + --1.3.6.1.4.1.3052.10.1.7.23 + +wmsMpRACH OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Wireless modem max power RACH" + ::= { wirelessModemStatus 24 } + --1.3.6.1.4.1.3052.10.1.7.24 + +wmsMinRxLevel OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Wireless modem minimum receive level" + ::= { wirelessModemStatus 25 } + --1.3.6.1.4.1.3052.10.1.7.25 + +wmsBaseCoeff OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Wireless modem base coefficient" + ::= { wirelessModemStatus 26 } + --1.3.6.1.4.1.3052.10.1.7.26 + +wmsSIMStatus OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "WWireless modem SIM status" + ::= { wirelessModemStatus 27 } + --1.3.6.1.4.1.3052.10.1.7.27 + +wmsICCID OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Wireless modem SIM ICCID" + ::= { wirelessModemStatus 28 } + --1.3.6.1.4.1.3052.10.1.7.28 + +wmsModemType OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Wireless modem type" + ::= { wirelessModemStatus 29 } + --1.3.6.1.4.1.3052.10.1.7.29 + + +--*************************************************************************************** +--AC Power Monitor Section 1.8 +--*************************************************************************************** + +acpmStatusTable OBJECT-TYPE + SYNTAX SEQUENCE OF ACPMStatus + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "AC power monitor status table" + ::= { acPowerMonitorStatus 1 } + --1.3.6.1.4.1.3052.10.1.8.1 + +acpmStatusEntry OBJECT-TYPE + SYNTAX ACPMStatus + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "AC power monitor status table entry" + INDEX { acpmsIndex } + ::= { acpmStatusTable 1 } + --1.3.6.1.4.1.3052.10.1.8.1.1 + +acpmsIndex OBJECT-TYPE + SYNTAX Integer32 (1..6) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Index for AC power monitors" + ::= { acpmStatusEntry 1 } + --1.3.6.1.4.1.3052.10.1.8.1.1.1 + +acpmsName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Name for the AC power monitor device." + ::= { acpmStatusEntry 2 } + --1.3.6.1.4.1.3052.10.1.8.1.1.2 + +acpmsAvgVoltageValueStr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Average voltage, in volts. This is calculated using the formula + (register * PT ratio * 0.1). This could be either the average of + the phase voltages, or the sum of the phase voltages, depending + on device configuration." + ::= { acpmStatusEntry 3 } + --1.3.6.1.4.1.3052.10.1.8.1.1.3 + +acpmsAvgVoltageMinStr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Minimum average voltage value since last reset, in volts." + ::= { acpmStatusEntry 4 } + --1.3.6.1.4.1.3052.10.1.8.1.1.4 + +acpmsAvgVoltageMaxStr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Maximum average voltage value since last reset, in volts." + ::= { acpmStatusEntry 5 } + --1.3.6.1.4.1.3052.10.1.8.1.1.5 + +acpmsAvgVoltageAvgStr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Average average voltage value since last reset, in volts. This is + the unit's average of its measurements of the average voltage + reported by the AC power monitor device." + ::= { acpmStatusEntry 6 } + --1.3.6.1.4.1.3052.10.1.8.1.1.6 + +acpmsAvgVoltageInEventState OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Event state of this AC power monitor voltage (Low, Normal, High, etc.)." + ::= { acpmStatusEntry 7 } + --1.3.6.1.4.1.3052.10.1.8.1.1.7 + +acpmsVoltagePhaseAValueStr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Phase A voltage, in volts. This is calculated using the formula + (register * PT ratio * 0.1)." + ::= { acpmStatusEntry 8 } + --1.3.6.1.4.1.3052.10.1.8.1.1.8 + +acpmsVoltagePhaseBValueStr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Phase B voltage, in volts. This is calculated using the formula + (register * PT ratio * 0.1)." + ::= { acpmStatusEntry 9 } + --1.3.6.1.4.1.3052.10.1.8.1.1.9 + +acpmsVoltagePhaseCValueStr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Phase C voltage, in volts. This is calculated using the formula + (register * PT ratio * 0.1)." + ::= { acpmStatusEntry 10 } + --1.3.6.1.4.1.3052.10.1.8.1.1.10 + +acpmsVoltageL1L2Value OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Line 1 to Line 2 voltage" + ::= { acpmStatusEntry 11 } + --1.3.6.1.4.1.3052.10.1.8.1.1.11 + +acpmsVoltageL2L3Value OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Line 2 to Line 3 voltage" + ::= { acpmStatusEntry 12 } + --1.3.6.1.4.1.3052.10.1.8.1.1.12 + +acpmsVoltageL3L1Value OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Line 3 to Line 1 voltage" + ::= { acpmStatusEntry 13 } + --1.3.6.1.4.1.3052.10.1.8.1.1.13 + + +acpmsAvgCurrentValueStr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Average current, in amps. This is calculated using the formula + (register * CT ratio * 0.001). This could be either the average of + the phase currents, or the sum of the phase currents, depending on + device configuration." + ::= { acpmStatusEntry 14 } + --1.3.6.1.4.1.3052.10.1.8.1.1.14 + +acpmsAvgCurrentMinStr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Minimum average current value since last reset, in amps." + ::= { acpmStatusEntry 15 } + --1.3.6.1.4.1.3052.10.1.8.1.1.15 + +acpmsAvgCurrentMaxStr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Maximum average current value since last reset, in amps." + ::= { acpmStatusEntry 16 } + --1.3.6.1.4.1.3052.10.1.8.1.1.16 + +acpmsAvgCurrentAvgStr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Average average current value since last reset, in amps. This is + the unit's average of its measurements of the average current reported + by the AC power monitor device." + ::= { acpmStatusEntry 17 } + --1.3.6.1.4.1.3052.10.1.8.1.1.17 + +acpmsAvgCurrentInEventState OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Event state of this AC power monitor current (Low, Normal, High, etc.)." + ::= { acpmStatusEntry 18 } + --1.3.6.1.4.1.3052.10.1.8.1.1.18 + +acpmsCurrentPhaseAValueStr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Phase A current, in amps. This is calculated using the formula + (register * CT ratio * 0.001)." + ::= { acpmStatusEntry 19 } + --1.3.6.1.4.1.3052.10.1.8.1.1.19 + +acpmsCurrentPhaseBValueStr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Phase B current, in amps. This is calculated using the formula + (register * CT ratio * 0.001)." + ::= { acpmStatusEntry 20 } + --1.3.6.1.4.1.3052.10.1.8.1.1.20 + +acpmsCurrentPhaseCValueStr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Phase C current, in amps. This is calculated using the formula + (register * CT ratio * 0.001)." + ::= { acpmStatusEntry 21 } + --1.3.6.1.4.1.3052.10.1.8.1.1.21 + +acpmsAvgFreqValueStr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Frequency, in hertz. On the YD2010, this is calculated using the + formula (register * 0.00106813). On the WattsOn, this is calculated + using the formula (register * 0.1)." + ::= { acpmStatusEntry 22 } + --1.3.6.1.4.1.3052.10.1.8.1.1.22 + +acpmsAvgFreqMinStr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Minimum frequency value since last reset, in hertz." + ::= { acpmStatusEntry 23 } + --1.3.6.1.4.1.3052.10.1.8.1.1.23 + +acpmsAvgFreqMaxStr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Maximum frequency value since last reset, in hertz." + ::= { acpmStatusEntry 24 } + --1.3.6.1.4.1.3052.10.1.8.1.1.24 + +acpmsAvgFreqAvgStr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Average frequency value since last reset, in hertz. This is the + unit's average of its measurements of the average frequency reported + by the AC power monitor device." + ::= { acpmStatusEntry 25 } + --1.3.6.1.4.1.3052.10.1.8.1.1.25 + +acpmsAvgFreqInEventState OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Event state of this AC power monitor frequency (Low, Normal, High, etc.)." + ::= { acpmStatusEntry 26 } + --1.3.6.1.4.1.3052.10.1.8.1.1.26 + +acpmsTRPValueStr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Total real power, in watts. On the YD2010, this is calculated using + the formula (register * PT ratio * CT ratio * Urg * 0.4), where Urg is + the voltage range taken from register 0x30A. On the WattsOn models, + this is calculated using the formula (register * PT * CT)." + ::= { acpmStatusEntry 27 } + --1.3.6.1.4.1.3052.10.1.8.1.1.27 + +acpmsTRPMinStr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Minimum total real power value since last reset, in watts." + ::= { acpmStatusEntry 28 } + --1.3.6.1.4.1.3052.10.1.8.1.1.28 + +acpmsTRPMaxStr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Maximum total real power value since last reset, in watts." + ::= { acpmStatusEntry 29 } + --1.3.6.1.4.1.3052.10.1.8.1.1.29 + +acpmsTRPAvgStr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Average total real power value since last reset, in watts. This is + the unit's average of its measurements of the average total real power + reported by the AC power monitor device." + ::= { acpmStatusEntry 30 } + --1.3.6.1.4.1.3052.10.1.8.1.1.30 + +acpmsTRPInEventState OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Event state of this AC power monitor total real power (Low, Normal, + High, etc.)." + ::= { acpmStatusEntry 31 } + --1.3.6.1.4.1.3052.10.1.8.1.1.31 + +acpmsRPPhaseAValueStr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Phase A real power, in watts. On the YD2010, this is calculated using + the formula (register * PT ratio * CT ratio * Urg * 0.4), where Urg is + the voltage range taken from register 0x30A. On the WattsOn, this is + calculated using the formula (register * PT * CT)." + ::= { acpmStatusEntry 32 } + --1.3.6.1.4.1.3052.10.1.8.1.1.32 + +acpmsRPPhaseBValueStr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Phase B real power, in watts. On the YD2010, this is calculated using + the formula (register * PT ratio * CT ratio * Urg * 0.4), where Urg is + the voltage range taken from register 0x30A. On the WattsOn, this is + calculated using the formula (register * PT * CT)." + ::= { acpmStatusEntry 33 } + --1.3.6.1.4.1.3052.10.1.8.1.1.33 + +acpmsRPPhaseCValueStr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Phase C real power, in watts. On the YD2010, this is calculated using + the formula (register * PT ratio * CT ratio * Urg * 0.4), where Urg is + the voltage range taken from register 0x30A. On the WattsOn, this is + calculated using the formula (register * PT * CT)." + ::= { acpmStatusEntry 34 } + --1.3.6.1.4.1.3052.10.1.8.1.1.34 + +acpmsCombined OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Combined status string intended to be parsed by NMS: + name`deviceState`deviceStateColorCode`voltage`current`frequency`power~voltageEventState`voltageColorCode`currentEventState`currentColorCode`frequencyEventState`freuencyColorCode`powerEventState`powerColorCode" + ::= { acpmStatusEntry 35 } + --1.3.6.1.4.1.3052.10.1.8.1.1.35 + +acpmsTPFValueStr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Total power factor." + ::= { acpmStatusEntry 36 } + --1.3.6.1.4.1.3052.10.1.8.1.1.36 + +acpmsTPFMinStr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Total power factor minimum value since last reset." + ::= { acpmStatusEntry 37 } + --1.3.6.1.4.1.3052.10.1.8.1.1.37 + +acpmsTPFMaxStr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Total power factor maximum value since last reset." + ::= { acpmStatusEntry 38 } + --1.3.6.1.4.1.3052.10.1.8.1.1.38 + +acpmsTPFAvgStr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Total power factor average value since last reset." + ::= { acpmStatusEntry 39 } + --1.3.6.1.4.1.3052.10.1.8.1.1.39 + +acpmsTPFInEventState OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Total power factor event state." + ::= { acpmStatusEntry 40 } + --1.3.6.1.4.1.3052.10.1.8.1.1.40 + +acpmsPFPhaseAValueStr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Phase A power factor." + ::= { acpmStatusEntry 41 } + --1.3.6.1.4.1.3052.10.1.8.1.1.41 + +acpmsPFPhaseBValueStr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Phase B power factor." + ::= { acpmStatusEntry 42 } + --1.3.6.1.4.1.3052.10.1.8.1.1.42 + +acpmsPFPhaseCValueStr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Phase C power factor." + ::= { acpmStatusEntry 43 } + --1.3.6.1.4.1.3052.10.1.8.1.1.43 + +acpmsTRcPValueStr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Total reactive power, in VAR." + ::= { acpmStatusEntry 44 } + --1.3.6.1.4.1.3052.10.1.8.1.1.44 + +acpmsTRcPMinStr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Total reactive power minimum value since last reset, in VAR." + ::= { acpmStatusEntry 45 } + --1.3.6.1.4.1.3052.10.1.8.1.1.45 + +acpmsTRcPMaxStr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Total reactive power maximum value since last reset, in VAR." + ::= { acpmStatusEntry 46 } + --1.3.6.1.4.1.3052.10.1.8.1.1.46 + +acpmsTRcPAvgStr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Total reactive power average value since last reset, in VAR." + ::= { acpmStatusEntry 47 } + --1.3.6.1.4.1.3052.10.1.8.1.1.47 + +acpmsRcPPhaseAValueStr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Phase A reactive power, in VAR." + ::= { acpmStatusEntry 48 } + --1.3.6.1.4.1.3052.10.1.8.1.1.48 + +acpmsRcPPhaseBValueStr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Phase B reactive power, in VAR." + ::= { acpmStatusEntry 49 } + --1.3.6.1.4.1.3052.10.1.8.1.1.49 + +acpmsRcPPhaseCValueStr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Phase C reactive power, in VAR." + ::= { acpmStatusEntry 50 } + --1.3.6.1.4.1.3052.10.1.8.1.1.50 + +acpmsTAPValueStr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Total apparent power, in VA." + ::= { acpmStatusEntry 51 } + --1.3.6.1.4.1.3052.10.1.8.1.1.51 + +acpmsTAPMinStr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Total apparent power minimum value since last reset, in VA." + ::= { acpmStatusEntry 52 } + --1.3.6.1.4.1.3052.10.1.8.1.1.52 + +acpmsTAPMaxStr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Total apparent power maximum value since last reset, in VA." + ::= { acpmStatusEntry 53 } + --1.3.6.1.4.1.3052.10.1.8.1.1.53 + +acpmsTAPAvgStr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Total apparent power average value since last reset, in VA." + ::= { acpmStatusEntry 54 } + --1.3.6.1.4.1.3052.10.1.8.1.1.54 + +acpmsAPPhaseAValueStr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Phase A apparent power, in VA." + ::= { acpmStatusEntry 55 } + --1.3.6.1.4.1.3052.10.1.8.1.1.55 + +acpmsAPPhaseBValueStr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Phase B apparent power, in VA." + ::= { acpmStatusEntry 56 } + --1.3.6.1.4.1.3052.10.1.8.1.1.56 + +acpmsAPPhaseCValueStr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Phase C apparent power, in VA." + ::= { acpmStatusEntry 57 } + --1.3.6.1.4.1.3052.10.1.8.1.1.57 + +acpmsTotalEnergyWh OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Total energy, in Wh." + ::= { acpmStatusEntry 58 } + --1.3.6.1.4.1.3052.10.1.8.1.1.58 + +acpmsTotalEnergyVAR OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Total reactive energy, in VAR." + ::= { acpmStatusEntry 59 } + --1.3.6.1.4.1.3052.10.1.8.1.1.59 + +acpmsTotalEnergyVA OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Total apparent energy, in VA." + ::= { acpmStatusEntry 60 } + --1.3.6.1.4.1.3052.10.1.8.1.1.60 + +acmpsAvgVoltageAlarmDatetime OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The time of the last Average Voltage alarm + triggerred in the AC monitor + MM/DD/YY HH:MM:SS format. + + The possible events are High, Very High, + Low, and Very Low. + + For outputs, this object is a null string." + ::= { acpmStatusEntry 61 } + --1.3.6.1.4.1.3052.10.1.8.1.1.61 + +acmpsAvgCurrentAlarmDatetime OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The time of the last Average Current alarm + triggerred in the AC monitor + MM/DD/YY HH:MM:SS format. + + The possible events are High, Very High, + Low, and Very Low. + + For outputs, this object is a null string." + ::= { acpmStatusEntry 62 } + --1.3.6.1.4.1.3052.10.1.8.1.1.62 + +acmpsFreqAlarmDatetime OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The time of the last Frequency alarm + triggerred in the AC monitor + MM/DD/YY HH:MM:SS format. + + The possible events are High, Very High, + Low, and Very Low. + + For outputs, this object is a null string." + ::= { acpmStatusEntry 63 } + --1.3.6.1.4.1.3052.10.1.8.1.1.63 + +acmpsRealPowerAlarmDatetime OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The time of the last Real Power alarm + triggerred in the AC monitor + MM/DD/YY HH:MM:SS format. + + The possible events are High, Very High, + Low, and Very Low. + + For outputs, this object is a null string." + ::= { acpmStatusEntry 64 } + --1.3.6.1.4.1.3052.10.1.8.1.1.64 + +acmpsPowerFactorAlarmDatetime OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The time of the last Power Factor alarm + triggerred in the AC monitor + MM/DD/YY HH:MM:SS format. + + The possible events are Low, and Very Low. + + For outputs, this object is a null string." + ::= { acpmStatusEntry 65 } + --1.3.6.1.4.1.3052.10.1.8.1.1.66 + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + +--*************************************************************************************** +--HVAC Status Section 1.11 +--*************************************************************************************** +--*************************************************************************************** +--Asentria HVAC Status Section 1.11.2 +--*************************************************************************************** + +evHVACStatusBardSystem1Stage1Cooling OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Bard HVAC: System 1 stage 1 cooling status." + ::= { evHVACStatusBardSystem1Stage1 1 } + --1.3.6.1.4.1.3052.10.1.11.2.1.1.1 + +evHVACStatusBardSystem1Stage2Cooling OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Bard HVAC: System 1 stage 2 cooling status." + ::= { evHVACStatusBardSystem1Stage2 1 } + --1.3.6.1.4.1.3052.10.1.11.2.1.2.1 + +evHVACStatusBardSystem1Blower OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Bard HVAC: System 1 blower status." + ::= { evHVACStatusBardSystem1 3 } + --1.3.6.1.4.1.3052.10.1.11.2.1.3 + +evHVACStatusBardSystem1Heating OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Bard HVAC: System 1 heating status." + ::= { evHVACStatusBardSystem1 4 } + --1.3.6.1.4.1.3052.10.1.11.2.1.4 + +evHVACStatusBardSystem1Economizer OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Bard HVAC: System 1 heating status." + ::= { evHVACStatusBardSystem1 5 } + --1.3.6.1.4.1.3052.10.1.11.2.1.5 + +evHVACStatusBardSystem2Stage1Cooling OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Bard HVAC: System 2 stage 1 cooling status." + ::= { evHVACStatusBardSystem2Stage1 1 } + --1.3.6.1.4.1.3052.10.1.11.2.2.1.1 + +evHVACStatusBardSystem2Stage2Cooling OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Bard HVAC: System 2 stage 2 cooling status." + ::= { evHVACStatusBardSystem2Stage2 1 } + --1.3.6.1.4.1.3052.10.1.11.2.2.2.1 + +evHVACStatusBardSystem2Blower OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Bard HVAC: System 2 blower status." + ::= { evHVACStatusBardSystem2 3 } + --1.3.6.1.4.1.3052.10.1.11.2.2.3 + +evHVACStatusBardSystem2Heating OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Bard HVAC: System 2 heating status." + ::= { evHVACStatusBardSystem2 4 } + --1.3.6.1.4.1.3052.10.1.11.2.2.4 + +evHVACStatusBardSystem2Economizer OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Bard HVAC: System 2 heating status." + ::= { evHVACStatusBardSystem2 5 } + --1.3.6.1.4.1.3052.10.1.11.2.2.5 + +evHVACStatusBardTempAvg OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Bard HVAC: Average temperature." + ::= { evHVACStatusBard 3 } + --1.3.6.1.4.1.3052.10.1.11.2.3 + +evHVACStatusBardTempLocal OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Bard HVAC: Local temperature." + ::= { evHVACStatusBard 4 } + --1.3.6.1.4.1.3052.10.1.11.2.4 + +evHVACStatusBardTempRemote1 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Bard HVAC: Remote 1 temperature." + ::= { evHVACStatusBardTempRemote 1 } + --1.3.6.1.4.1.3052.10.1.11.2.5.1 + +evHVACStatusBardTempRemote2 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Bard HVAC: Remote 2 temperature." + ::= { evHVACStatusBardTempRemote 2 } + --1.3.6.1.4.1.3052.10.1.11.2.5.2 + +evHVACStatusBardDehumidification OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Bard HVAC: Dehumidification status." + ::= { evHVACStatusBard 6 } + --1.3.6.1.4.1.3052.10.1.11.2.6 + +evHVACStatusBardLEDsCooling1 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Bard HVAC: Cooling LED 1." + ::= { evHVACStatusBardLEDsCooling 1 } + --1.3.6.1.4.1.3052.10.1.11.2.7.1.1 + +evHVACStatusBardLEDsCooling2 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Bard HVAC: Cooling LED 2." + ::= { evHVACStatusBardLEDsCooling 2 } + --1.3.6.1.4.1.3052.10.1.11.2.7.1.2 + +evHVACStatusBardLEDsCooling3 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Bard HVAC: Cooling LED 3." + ::= { evHVACStatusBardLEDsCooling 3 } + --1.3.6.1.4.1.3052.10.1.11.2.7.1.3 + +evHVACStatusBardLEDsCooling4 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Bard HVAC: Cooling LED 4." + ::= { evHVACStatusBardLEDsCooling 4 } + --1.3.6.1.4.1.3052.10.1.11.2.7.1.4 + +evHVACStatusBardLEDsHeating1 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Bard HVAC: Heating LED 1." + ::= { evHVACStatusBardLEDsHeating 1 } + --1.3.6.1.4.1.3052.10.1.11.2.7.2.1 + +evHVACStatusBardLEDsHeating2 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Bard HVAC: Heating LED 2." + ::= { evHVACStatusBardLEDsHeating 2 } + --1.3.6.1.4.1.3052.10.1.11.2.7.2.2 + +evHVACStatusBardLEDsHeating3 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Bard HVAC: Heating LED 3." + ::= { evHVACStatusBardLEDsHeating 3 } + --1.3.6.1.4.1.3052.10.1.11.2.7.2.3 + +evHVACStatusBardLEDsHeating4 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Bard HVAC: Heating LED 4." + ::= { evHVACStatusBardLEDsHeating 4 } + --1.3.6.1.4.1.3052.10.1.11.2.7.2.4 + +evHVACStatusBardLEDsDeHumid1 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Bard HVAC: Dehumidification LED 1." + ::= { evHVACStatusBardLEDsDeHumid 1 } + --1.3.6.1.4.1.3052.10.1.11.2.7.3.1 + +evHVACStatusBardGenerator OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Bard HVAC: Backup generator status." + ::= { evHVACStatusBard 7 } + --1.3.6.1.4.1.3052.10.1.11.2.8 + +evHVACStatusBardAlarmBoardState OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Bard HVAC: Alarm board state." + ::= { evHVACStatusBard 8 } + --1.3.6.1.4.1.3052.10.1.11.2.9 + +evHVACStatusBardASSystem1PowerLoss OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Bard HVAC Alarm Status: System 1 power loss." + ::= { evHVACStatusBardASSystem1 1 } + --1.3.6.1.4.1.3052.10.1.11.2.10.1.1 + +evHVACStatusBardASSystem1Lockout OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Bard HVAC Alarm Status: System 1 ref. lockout." + ::= { evHVACStatusBardASSystem1 2 } + --1.3.6.1.4.1.3052.10.1.11.2.10.1.2 + +evHVACStatusBardASSystem2PowerLoss OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Bard HVAC Alarm Status: System 2 power loss." + ::= { evHVACStatusBardASSystem2 1 } + --1.3.6.1.4.1.3052.10.1.11.2.10.2.1 + +evHVACStatusBardASSystem2Lockout OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Bard HVAC Alarm Status: System 2 ref. lockout." + ::= { evHVACStatusBardASSystem2 2 } + --1.3.6.1.4.1.3052.10.1.11.2.10.2.2 + +evHVACStatusBardASFire OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Bard HVAC Alarm Status: Fire / smoke." + ::= { evHVACStatusBardAlarmStatus 3 } + --1.3.6.1.4.1.3052.10.1.11.2.10.3 + +evHVACStatusBardASTempLowAlarm OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Bard HVAC Alarm Status: Low temperature." + ::= { evHVACStatusBardASTemp 1 } + --1.3.6.1.4.1.3052.10.1.11.2.10.4.1 + +evHVACStatusBardASTempHighAlarm OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Bard HVAC Alarm Status: High temperature." + ::= { evHVACStatusBardASTemp 2 } + --1.3.6.1.4.1.3052.10.1.11.2.10.4.2 + +evHVACStatusBardASTempVHighAlarm OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Bard HVAC Alarm Status: Very high temperature." + ::= { evHVACStatusBardASTemp 3 } + --1.3.6.1.4.1.3052.10.1.11.2.10.4.3 + +evHVACStatusBardASFailure OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Bard HVAC Alarm Status: Controller failure." + ::= { evHVACStatusBardAlarmStatus 5 } + --1.3.6.1.4.1.3052.10.1.11.2.10.5 + +evHVACStatusBardConnState OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Connectivity state: 1 means unit has good connectivity to the + Bard HVAC controller, 0 otherwise." + ::= { evHVACStatusBard 11 } + --1.3.6.1.4.1.3052.10.1.11.2.11 + +--*************************************************************************************** +--Asentria HVAC Status Section 1.11.3 +--*************************************************************************************** + +evHVACStatusAsentriaSequenceTable OBJECT-TYPE + SYNTAX SEQUENCE OF HVACStatusAsentriaSequence + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Asentria HVAC sequence status table" + ::= { evHVACStatusAsentria 1 } + --1.3.6.1.4.1.3052.10.1.11.3.1 + +evHVACStatusAsentriaSequenceEntry OBJECT-TYPE + SYNTAX HVACStatusAsentriaSequence + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Asentria HVAC sequence status table entry" + INDEX { evHVACStatusAsentriaSequenceIndex } + ::= { evHVACStatusAsentriaSequenceTable 1 } + --1.3.6.1.4.1.3052.10.1.11.3.1.1 + +evHVACStatusAsentriaSequenceIndex OBJECT-TYPE + SYNTAX Integer32 (1..2) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Index for Asentria HVAC sequence" + ::= { evHVACStatusAsentriaSequenceEntry 1 } + --1.3.6.1.4.1.3052.10.1.11.3.1.1.1 + +evHVACStatusAsentriaSeqVentTime OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Asentria HVAC sequence time spent venting" + ::= { evHVACStatusAsentriaSequenceEntry 2 } + --1.3.6.1.4.1.3052.10.1.11.3.1.1.2 + +evHVACStatusAsentriaSeqCoolTime OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Asentria HVAC sequence time spent cooling" + ::= { evHVACStatusAsentriaSequenceEntry 3 } + --1.3.6.1.4.1.3052.10.1.11.3.1.1.3 + +evHVACStatusAsentriaSeqHeatTime OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Asentria HVAC sequence time spent heating" + ::= { evHVACStatusAsentriaSequenceEntry 4 } + --1.3.6.1.4.1.3052.10.1.11.3.1.1.4 + +evHVACStatusAsentriaSeqIdleTime OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Asentria HVAC sequence time spent idling" + ::= { evHVACStatusAsentriaSequenceEntry 5 } + --1.3.6.1.4.1.3052.10.1.11.3.1.1.5 + +evHVACStatusAsentriaUnitTable OBJECT-TYPE + SYNTAX SEQUENCE OF HVACStatusAsentriaUnit + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Asentria HVAC unit status table" + ::= { evHVACStatusAsentria 2 } + --1.3.6.1.4.1.3052.10.1.11.3.2 + +evHVACStatusAsentriaUnitEntry OBJECT-TYPE + SYNTAX HVACStatusAsentriaUnit + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Asentria HVAC unit status table entry" + INDEX { evHVACStatusAsentriaUnitIndex } + ::= { evHVACStatusAsentriaUnitTable 1 } + --1.3.6.1.4.1.3052.10.1.11.3.2.1 + +evHVACStatusAsentriaUnitIndex OBJECT-TYPE + SYNTAX Integer32 (1..2) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Index for Asentria HVAC unit" + ::= { evHVACStatusAsentriaUnitEntry 1 } + --1.3.6.1.4.1.3052.10.1.11.3.2.1.1 + +evHVACStatusAsentriaUnitState OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Asentria HVAC unit status" + ::= { evHVACStatusAsentriaUnitEntry 2 } + --1.3.6.1.4.1.3052.10.1.11.3.2.1.2 + +evHVACStatusAsentriaUnitVentTime OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Asentria HVAC unit time spent venting" + ::= { evHVACStatusAsentriaUnitEntry 3 } + --1.3.6.1.4.1.3052.10.1.11.3.2.1.3 + +evHVACStatusAsentriaUnitCoolTime OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Asentria HVAC unit time spent cooling" + ::= { evHVACStatusAsentriaUnitEntry 4 } + --1.3.6.1.4.1.3052.10.1.11.3.2.1.4 + +evHVACStatusAsentriaUnitHeatTime OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Asentria HVAC unit time spent heating" + ::= { evHVACStatusAsentriaUnitEntry 5 } + --1.3.6.1.4.1.3052.10.1.11.3.2.1.5 + +evHVACStatusAsentriaUnitIdleTime OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Asentria HVAC unit time spent idling" + ::= { evHVACStatusAsentriaUnitEntry 6 } + --1.3.6.1.4.1.3052.10.1.11.3.2.1.6 + +evHVACStatusAsentriaBackupEvent OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Asentria HVAC backup event" + ::= { evHVACStatusAsentria 3 } + --1.3.6.1.4.1.3052.10.1.11.3.3 + +evHVACStatusAsentriaFireEvent OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Asentria HVAC smoke/fire event" + ::= { evHVACStatusAsentria 4 } + --1.3.6.1.4.1.3052.10.1.11.3.4 + +evHVACStatusAsentriaTempOut OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Asentria HVAC temperature outside" + ::= { evHVACStatusAsentriaTemp 1 } + --1.3.6.1.4.1.3052.10.1.11.3.5.1 + +evHVACStatusAsentriaTempIn OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Asentria HVAC temperature inside" + ::= { evHVACStatusAsentriaTemp 2 } + --1.3.6.1.4.1.3052.10.1.11.3.5.2 + +evHVACStatusAsentriaHumidOut OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Asentria HVAC humidity outside" + ::= { evHVACStatusAsentriaHumid 1 } + --1.3.6.1.4.1.3052.10.1.11.3.6.1 + +evHVACStatusAsentriaHumidIn OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Asentria HVAC humidity inside" + ::= { evHVACStatusAsentriaHumid 2 } + --1.3.6.1.4.1.3052.10.1.11.3.6.2 + + +--*************************************************************************************** +--Airsys HVAC Status Section 1.11.4 +--*************************************************************************************** + +evHVACStatusAirsysAlarmUnitTable OBJECT-TYPE + SYNTAX SEQUENCE OF HVACStatusAirsysAlarmUnit + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Airsys HVAC unit alarm status table" + ::= { evHVACStatusAirsysAlarm 1 } + --1.3.6.1.4.1.3052.10.1.11.4.1.1 + +evHVACStatusAirsysAlarmUnitEntry OBJECT-TYPE + SYNTAX HVACStatusAirsysAlarmUnit + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Airsys HVAC unit alarm status table entry" + INDEX { evHVACStatusAirsysAlarmUnitIndex } + ::= { evHVACStatusAirsysAlarmUnitTable 1 } + --1.3.6.1.4.1.3052.10.1.11.4.1.1.1 + +evHVACStatusAirsysAlarmUnitIndex OBJECT-TYPE + SYNTAX Integer32 (1..2) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Index for Airsys HVAC unit alarms" + ::= { evHVACStatusAirsysAlarmUnitEntry 1 } + --1.3.6.1.4.1.3052.10.1.11.4.1.1.1.1 + +evHVACStatusAirsysAlarmUnitLowPress OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Airsys HVAC unit low pressure event" + ::= { evHVACStatusAirsysAlarmUnitEntry 2 } + --1.3.6.1.4.1.3052.10.1.11.4.1.1.1.2 + +evHVACStatusAirsysAlarmUnitHighPress OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Airsys HVAC unit high pressure event" + ::= { evHVACStatusAirsysAlarmUnitEntry 3 } + --1.3.6.1.4.1.3052.10.1.11.4.1.1.1.3 + +evHVACStatusAirsysAlarmUnitEvapFan OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Airsys HVAC unit AC power/evaporator fan overload event" + ::= { evHVACStatusAirsysAlarmUnitEntry 4 } + --1.3.6.1.4.1.3052.10.1.11.4.1.1.1.4 + +evHVACStatusAirsysAlarmUnitDirty OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Airsys HVAC unit dirty filter event" + ::= { evHVACStatusAirsysAlarmUnitEntry 5 } + --1.3.6.1.4.1.3052.10.1.11.4.1.1.1.5 + +evHVACStatusAirsysAlarmUnitDamper OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Airsys HVAC unit damper event" + ::= { evHVACStatusAirsysAlarmUnitEntry 6 } + --1.3.6.1.4.1.3052.10.1.11.4.1.1.1.6 + +evHVACStatusAirsysAlarmUnitSupProbe OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Airsys HVAC unit supply probe broken event" + ::= { evHVACStatusAirsysAlarmUnitEntry 7 } + --1.3.6.1.4.1.3052.10.1.11.4.1.1.1.7 + +evHVACStatusAirsysAlarmSmokeFire OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Airsys HVAC smoke/fire event" + ::= { evHVACStatusAirsysAlarm 2 } + --1.3.6.1.4.1.3052.10.1.11.4.1.2 + +evHVACStatusAirsysAlarmLowRoomTemp OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Airsys HVAC low temperature event" + ::= { evHVACStatusAirsysAlarm 3 } + --1.3.6.1.4.1.3052.10.1.11.4.1.3 + +evHVACStatusAirsysAlarmHighRoomTemp OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Airsys HVAC high temperature event" + ::= { evHVACStatusAirsysAlarm 4 } + --1.3.6.1.4.1.3052.10.1.11.4.1.4 + +evHVACStatusAirsysAlarmPower OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Airsys HVAC power failure event" + ::= { evHVACStatusAirsysAlarm 5 } + --1.3.6.1.4.1.3052.10.1.11.4.1.5 + +evHVACStatusAirsysAlarmpLAN OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Airsys HVAC pLAN event" + ::= { evHVACStatusAirsysAlarm 6 } + --1.3.6.1.4.1.3052.10.1.11.4.1.6 + +evHVACStatusAirsysAlarmClock OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Airsys HVAC clock card event" + ::= { evHVACStatusAirsysAlarm 7 } + --1.3.6.1.4.1.3052.10.1.11.4.1.7 + +evHVACStatusAirsysAlarmHumidProbe OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Airsys HVAC humidity probe broken event" + ::= { evHVACStatusAirsysAlarm 8 } + --1.3.6.1.4.1.3052.10.1.11.4.1.8 + +evHVACStatusAirsysAlarmOutProbe OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Airsys HVAC outdoor probe broken event" + ::= { evHVACStatusAirsysAlarm 9 } + --1.3.6.1.4.1.3052.10.1.11.4.1.9 + +evHVACStatusAirsysAlarmBothCompress OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Airsys HVAC both compressors running event" + ::= { evHVACStatusAirsysAlarm 10 } + --1.3.6.1.4.1.3052.10.1.11.4.1.10 + +evHVACStatusAirsysAlarmGenerator OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Airsys HVAC generator running event" + ::= { evHVACStatusAirsysAlarm 11 } + --1.3.6.1.4.1.3052.10.1.11.4.1.11 + +evHVACStatusAirsysAlarmConnection OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Airsys HVAC controller connection event" + ::= { evHVACStatusAirsysAlarm 12 } + --1.3.6.1.4.1.3052.10.1.11.4.1.12 + +evHVACStatusAirsysAlarmInProbe1 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Airsys HVAC indoor probe broken event" + ::= { evHVACStatusAirsysAlarm 13 } + --1.3.6.1.4.1.3052.10.1.11.4.1.13 + +evHVACStatusAirsysAlarmInProbe2 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Airsys HVAC backup indoor probe broken event" + ::= { evHVACStatusAirsysAlarm 14 } + --1.3.6.1.4.1.3052.10.1.11.4.1.14 + +evHVACStatusAirsysTempOut OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Airsys HVAC outdoor temperature" + ::= { evHVACStatusAirsys 2 } + --1.3.6.1.4.1.3052.10.1.11.4.2 + +evHVACStatusAirsysTempIn OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Airsys HVAC indoor temperature" + ::= { evHVACStatusAirsys 3 } + --1.3.6.1.4.1.3052.10.1.11.4.3 + +evHVACStatusAirsysTempInBackup OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Airsys HVAC backup indoor temperature" + ::= { evHVACStatusAirsys 4 } + --1.3.6.1.4.1.3052.10.1.11.4.4 + +evHVACStatusAirsysHumidIn OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Airsys HVAC indoor humidity" + ::= { evHVACStatusAirsys 5 } + --1.3.6.1.4.1.3052.10.1.11.4.5 + +evHVACStatusAirsysUnitTable OBJECT-TYPE + SYNTAX SEQUENCE OF HVACStatusAirsysUnit + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Airsys HVAC unit alarm status table" + ::= { evHVACStatusAirsys 6 } + --1.3.6.1.4.1.3052.10.1.11.4.6 + +evHVACStatusAirsysUnitEntry OBJECT-TYPE + SYNTAX HVACStatusAirsysUnit + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Airsys HVAC unit alarm status table entry" + INDEX { evHVACStatusAirsysUnitIndex } + ::= { evHVACStatusAirsysUnitTable 1 } + --1.3.6.1.4.1.3052.10.1.11.4.6.1 + +evHVACStatusAirsysUnitIndex OBJECT-TYPE + SYNTAX Integer32 (1..2) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Index for Airsys HVAC unit" + ::= { evHVACStatusAirsysUnitEntry 1 } + --1.3.6.1.4.1.3052.10.1.11.4.6.1.1 + +evHVACStatusAirsysUnitTempSupply OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Airsys HVAC unit supply temperature" + ::= { evHVACStatusAirsysUnitEntry 2 } + --1.3.6.1.4.1.3052.10.1.11.4.6.1.2 + +evHVACStatusAirsysUnitFanspeed OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Airsys HVAC unit fan speed" + ::= { evHVACStatusAirsysUnitEntry 3 } + --1.3.6.1.4.1.3052.10.1.11.4.6.1.3 + +evHVACStatusAirsysUnitFreeOpening OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Airsys HVAC unit free cooling vent opening percentage" + ::= { evHVACStatusAirsysUnitEntry 4 } + --1.3.6.1.4.1.3052.10.1.11.4.6.1.4 + +evHVACStatusAirsysUnitStatus OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Airsys HVAC unit running status" + ::= { evHVACStatusAirsysUnitEntry 5 } + --1.3.6.1.4.1.3052.10.1.11.4.6.1.5 + +evHVACStatusAirsysUnitLocked OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Airsys HVAC unit locked status" + ::= { evHVACStatusAirsysUnitEntry 6 } + --1.3.6.1.4.1.3052.10.1.11.4.6.1.6 + +evHVACStatusAirsysUnitCompressor OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Airsys HVAC unit state of compressor" + ::= { evHVACStatusAirsysUnitEntry 7 } + --1.3.6.1.4.1.3052.10.1.11.4.6.1.7 + +evHVACStatusAirsysUnitHeater OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Airsys HVAC unit state of heater" + ::= { evHVACStatusAirsysUnitEntry 8 } + --1.3.6.1.4.1.3052.10.1.11.4.6.1.8 + +evHVACStatusAirsysURuntimeSupplyFan OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Airsys HVAC unit run time of supply fan in hours" + ::= { evHVACStatusAirsysUnitEntry 9 } + --1.3.6.1.4.1.3052.10.1.11.4.6.1.9 + +evHVACStatusAirsysURuntimeCompressor OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Airsys HVAC unit run time of compressor in hours" + ::= { evHVACStatusAirsysUnitEntry 10 } + --1.3.6.1.4.1.3052.10.1.11.4.6.1.10 + +evHVACStatusAirsysURuntimeHeat OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Airsys HVAC unit run time of heating in hours" + ::= { evHVACStatusAirsysUnitEntry 11 } + --1.3.6.1.4.1.3052.10.1.11.4.6.1.11 + +evHVACStatusAirsysURuntimeFreeCooling OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Airsys HVAC unit run time of free cooling in hours" + ::= { evHVACStatusAirsysUnitEntry 12 } + --1.3.6.1.4.1.3052.10.1.11.4.6.1.12 + +evHVACStatusAirsysUCountSupplyFan OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Airsys HVAC unit number of times supply fan has started" + ::= { evHVACStatusAirsysUnitEntry 13 } + --1.3.6.1.4.1.3052.10.1.11.4.6.1.13 + +evHVACStatusAirsysUCountCompressor OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Airsys HVAC unit number of times compressor has started" + ::= { evHVACStatusAirsysUnitEntry 14 } + --1.3.6.1.4.1.3052.10.1.11.4.6.1.14 + +evHVACStatusAirsysUCountHeat OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Airsys HVAC unit number of times heating has started" + ::= { evHVACStatusAirsysUnitEntry 15 } + --1.3.6.1.4.1.3052.10.1.11.4.6.1.15 + +evHVACStatusAirsysUCountFreeCooling OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Airsys HVAC unit number of times free cooling has started" + ::= { evHVACStatusAirsysUnitEntry 16 } + --1.3.6.1.4.1.3052.10.1.11.4.6.1.16 + +evHVACStatusAirsysDay OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Airsys HVAC controller day" + ::= { evHVACStatusAirsys 7 } + --1.3.6.1.4.1.3052.10.1.11.4.7 + +evHVACStatusAirsysDate OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Airsys HVAC controller date" + ::= { evHVACStatusAirsys 8 } + --1.3.6.1.4.1.3052.10.1.11.4.8 + +evHVACStatusAirsysTime OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Airsys HVAC controller time" + ::= { evHVACStatusAirsys 9 } + --1.3.6.1.4.1.3052.10.1.11.4.9 + +evHVACStatusAirsysVersion OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Airsys HVAC controller software version" + ::= { evHVACStatusAirsys 10 } + --1.3.6.1.4.1.3052.10.1.11.4.10 + +--*************************************************************************************** +--Battery Backup Status Section 1.12 +--*************************************************************************************** +liBattPercentCharge OBJECT-TYPE + SYNTAX Integer32 (1..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Lithium Battery State Charge in Percent (0% to 100%)" + ::= { liBattStatus 1 } + --1.3.6.1.4.1.3052.10.1.12.1.1 + +liBattRunning OBJECT-TYPE + SYNTAX Integer32 (0..1) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Is the unit running on battery backup: (TRUE/FALSE) or (1/0)" + ::= { liBattStatus 2 } + --1.3.6.1.4.1.3052.10.1.12.1.2 + +--*************************************************************************************** +--EventSensor Basics Section 2.1 +--*************************************************************************************** + +esNumberEventSensors OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of EventSensors recognized by the unit, + including the internal EventSensor. + Range: 1-17" + ::= { eventSensorBasics 1 } + --1.3.6.1.4.1.3052.10.2.1.1 + +esTable OBJECT-TYPE + SYNTAX SEQUENCE OF ESExist + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The table of what EventSensors are attached to the unit, + including the internal EventSensor" + ::= { eventSensorBasics 2 } + --1.3.6.1.4.1.3052.10.2.1.2 + +esEntry OBJECT-TYPE + SYNTAX ESExist + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table entry for EventSensor table" + INDEX { esIndex } + ::= { esTable 1 } + --1.3.6.1.4.1.3052.10.2.1.2.1 + +esIndex OBJECT-TYPE + SYNTAX Integer32 (1..200) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This number refers to an EventSensor; it has the + same meaning as the esIndexES object (see above), + except that this object is used only within the + esTable branch. + + This object's allowable values are 1 through 16, + and 200. 200 always refers to the EventSensor + inside the unit. 1 through 16 refer to additional + attached EventSensors. + + The number corresponding to an EventSensor is + determined by the user at the initial configuration + time. If there is an internal sensor in the unit, + it will always be the first item in the Sensor + Events setup menu. + + For example, if a new EventSensor is configured as + the 2nd entry AFTER the internal EventSensor (if + one exists) in the Sensor Events Setup Menu, then + that EventSensor will be known from then on as + EventSensor 2. All point indeces with esIndex=2 + will now refer to that particular EventSensor. + " + ::= { esEntry 1 } + --1.3.6.1.4.1.3052.10.2.1.2.1.1 + +esName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The name of the EventSensor" + ::= { esEntry 2 } + --1.3.6.1.4.1.3052.10.2.1.2.1.2 + +esID OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The factory-assigned ID of the EventSensor" + ::= { esEntry 3 } + --1.3.6.1.4.1.3052.10.2.1.2.1.3 + +esNumberTempSensors OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of temperature sensors on the EventSensor" + ::= { esEntry 4 } + --1.3.6.1.4.1.3052.10.2.1.2.1.4 + +esTempReportingMode OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Description of how temperature values should + be interpreted." + ::= { esEntry 5 } + --1.3.6.1.4.1.3052.10.2.1.2.1.5 + +esNumberCCs OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of contact closures on the EventSensor." + ::= { esEntry 6 } + --1.3.6.1.4.1.3052.10.2.1.2.1.6 + +esCCReportingMode OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Description of how CC values should be interpreted." + ::= { esEntry 7 } + --1.3.6.1.4.1.3052.10.2.1.2.1.7 + +esNumberHumidSensors OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of humidity sensors on the EventSensor." + ::= { esEntry 8 } + --1.3.6.1.4.1.3052.10.2.1.2.1.8 + +esHumidReportingMode OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Description of how humidity sensor values should be + interpreted." + ::= { esEntry 9 } + --1.3.6.1.4.1.3052.10.2.1.2.1.9 + +esNumberNoiseSensors OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of noise sensors on the EventSensor." + ::= { esEntry 10 } + --1.3.6.1.4.1.3052.10.2.1.2.1.10 + +esNoiseReportingMode OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Description of how noise sensor values should be + interpreted." + ::= { esEntry 11 } + --1.3.6.1.4.1.3052.10.2.1.2.1.11 + +esNumberAirflowSensors OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of airflow sensors on the EventSensor." + ::= { esEntry 12 } + --1.3.6.1.4.1.3052.10.2.1.2.1.12 + +esAirflowReportingMode OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Description of how airflow sensor values should be + interpreted." + ::= { esEntry 13 } + --1.3.6.1.4.1.3052.10.2.1.2.1.13 + +esNumberAnalog OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of analog inputs on the EventSensor." + ::= { esEntry 14 } + --1.3.6.1.4.1.3052.10.2.1.2.1.14 + +esAnalogReportingMode OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Description of how analog input values should be + interpreted." + ::= { esEntry 15 } + --1.3.6.1.4.1.3052.10.2.1.2.1.15 + +esNumberOutputs OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of outputs (relay or power) on the EventSensor" + ::= { esEntry 16 } + --1.3.6.1.4.1.3052.10.2.1.2.1.16 + +esOutputReportingMode OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Description of how output values should be interpreted." + ::= { esEntry 17 } + --1.3.6.1.4.1.3052.10.2.1.2.1.17 + +esTempCombinedStatus OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Combined status string intended to be parsed by NMS: + name`value`scale`eventState`eventColorCode" + ::= { esEntry 18 } + --1.3.6.1.4.1.3052.10.2.1.2.1.18 + +esCCCombinedStatusBlock1 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Combined status string intended to be parsed by NMS: + numInBlock~name1`value1`eventColorCode1`alias1~name2`value2`eventColorCode2`alias2~...name8`value8`eventColorCode8`alias8" + ::= { esEntry 19 } + --1.3.6.1.4.1.3052.10.2.1.2.1.19 + +esCCCombinedStatusBlock2 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Combined status string intended to be parsed by NMS: + numInBlock~name9`value9`eventColorCode9`alias9~name10`value10`eventColorCode10`alias10~...name16`value16`eventColorCode16`alias16" + ::= { esEntry 20 } + --1.3.6.1.4.1.3052.10.2.1.2.1.20 + +esCCCombinedStatusBlock3 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Combined status string intended to be parsed by NMS: + numInBlock~name17`value17`eventColorCode17`alias17~name18`value18`eventColorCode18`alias18~...name24`value24`eventColorCode24`alias24" + ::= { esEntry 21 } + --1.3.6.1.4.1.3052.10.2.1.2.1.21 + +esCCCombinedStatusBlock4 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Combined status string intended to be parsed by NMS: + numInBlock~name25`value25`eventColorCode25`alias25~name26`value26`eventColorCode26`alias26~...name32`value32`eventColorCode32`alias32" + ::= { esEntry 22 } + --1.3.6.1.4.1.3052.10.2.1.2.1.22 + +esCCCombinedStatusBlock5 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Combined status string intended to be parsed by NMS: + numInBlock~name33`value33`eventColorCode33`alias33~name34`value34`eventColorCode34`alias35~...name40`value40`eventColorCode40`alias40" + ::= { esEntry 23 } + --1.3.6.1.4.1.3052.10.2.1.2.1.23 + +esCCCombinedStatusBlock6 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Combined status string intended to be parsed by NMS: + numInBlock~name41`value41`eventColorCode41`alias41~name42`value42`eventColorCode42`alias43~...name48`value48`eventColorCode48`alias48" + ::= { esEntry 24 } + --1.3.6.1.4.1.3052.10.2.1.2.1.24 + +esCCCombinedStatusBlock7 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Combined status string intended to be parsed by NMS: + numInBlock~name49`value49`eventColorCode49`alias49~name50`value50`eventColorCode50`alias50~...name56`value56`eventColorCode56`alias56" + ::= { esEntry 25 } + --1.3.6.1.4.1.3052.10.2.1.2.1.25 + +esCCCombinedStatusBlock8 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Combined status string intended to be parsed by NMS: + numInBlock~name57`value57`eventColorCode57`alias57~name57`value57`eventColorCode564`alias57~...name64`value64`eventColorCode64`alias64" + ::= { esEntry 26 } + --1.3.6.1.4.1.3052.10.2.1.2.1.26 + +esHumidCombinedStatus OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Combined status string intended to be parsed by NMS: + name`value`eventState`eventColorCode" + ::= { esEntry 27 } + --1.3.6.1.4.1.3052.10.2.1.2.1.27 + +esAnalogCombinedStatusBlock1 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Combined status string intended to be parsed by NMS: + numInBlock~name1`value1`units1`eventState`eventColorCode1~name2`value2`units2`eventState`eventColorCode2~..." + ::= { esEntry 28 } + --1.3.6.1.4.1.3052.10.2.1.2.1.28 + +esAnalogCombinedStatusBlock2 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Combined status string intended to be parsed by NMS: + numInBlock~name9`value9`units9`eventState9`eventColorCode9~..." + ::= { esEntry 29 } + --1.3.6.1.4.1.3052.10.2.1.2.1.29 + +esAnalogCombinedStatusBlock3 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Combined status string intended to be parsed by NMS: + numInBlock~namex`valuex`unitsx`eventStatex`eventColorCodex~..." + ::= { esEntry 30 } + --1.3.6.1.4.1.3052.10.2.1.2.1.31 + +esAnalogCombinedStatusBlock4 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Combined status string intended to be parsed by NMS: + numInBlock~namex`valuex`unitsx`eventStatex`eventColorCodex~..." + ::= { esEntry 31 } + --1.3.6.1.4.1.3052.10.2.1.2.1.31 + +esAnalogCombinedStatusBlock5 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Combined status string intended to be parsed by NMS: + numInBlock~namex`valuex`unitsx`eventStatex`eventColorCodex~..." + ::= { esEntry 32 } + --1.3.6.1.4.1.3052.10.2.1.2.1.32 + +esAnalogCombinedStatusBlock6 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Combined status string intended to be parsed by NMS: + numInBlock~namex`valuex`unitsx`eventStatex`eventColorCodex~..." + ::= { esEntry 33 } + --1.3.6.1.4.1.3052.10.2.1.2.1.33 + +esOutputCombinedStatusBlock1 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Combined status string intended to be parsed by NMS: + numInBlock~namex`valuex`unitsx`eventStatex`eventColorCodex~..." + ::= { esEntry 34 } + --1.3.6.1.4.1.3052.10.2.1.2.1.34 + +esOutputCombinedStatusBlock2 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Combined status string intended to be parsed by NMS: + numInBlock`namex`valuex`aliasx~namey`valuey`aliasy~...namez`valuez`aliasz" + ::= { esEntry 35 } + --1.3.6.1.4.1.3052.10.2.1.2.1.35 + +esNewSensors OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "String representing the number of new (attached but unconfigured) EventSensors" + ::= { eventSensorBasics 3 } + --1.3.6.1.4.1.3052.10.2.1.3 + + +--*************************************************************************************** +--EventSensor Point Config Section 2.2 +--*************************************************************************************** + + + +esPointConfigTempTable OBJECT-TYPE + SYNTAX SEQUENCE OF ESPointConfigTemp + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table organizes 3 basic attributes of temperature + sensor points. A point is a particular sensor on an + EventSensor. The 3 point attributes organizes in this table + are: + 1. the configuration item (e.g., enable, name, etc.) + 2. the eventsensor on which this point resides + 3. the point number (always 1 for temp sensors) + + Points are referenced by a point config index. The point + config index is a string of 2 numbers separated by periods. + It contains all the information necessary for getting a + piece of data off an event sensor within the context of this + emperature point config table ; namely, which EventSensor, + and which sensor (a.k.a. point) (always 1 for temperature + sensors). + " + ::= { eventSensorPointConfig 1 } + --1.3.6.1.4.1.3052.10.2.2.1 + +esPointConfigTempEntry OBJECT-TYPE + SYNTAX ESPointConfigTemp + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry for EventSensor point config temperature table" + INDEX { espcTempIndexES, espcTempIndexPoint } + ::= { esPointConfigTempTable 1 } + --1.3.6.1.4.1.3052.10.2.2.1.1 + +espcTempIndexES OBJECT-TYPE + SYNTAX Integer32 (1..200) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The part of the point index that refers to an + EventSensor. + + The point config index is a string of 2 numbers separated + by a period. It contains all the information + necessary for getting a piece of data off an event + sensor within the the context of the eventsensor point + config temperature table; namely, which EventSensor, + and which sensor (a.k.a. point). + + This object's allowable values are 1 through 16, + and 200. 200 always refers to the EventSensor + inside the unit. 1 through 16 refer to additional + attached EventSensors. + + The number corresponding to an EventSensor is + determined by the user at the initial configuration + time. If there is an internal sensor in the unit, + it will always be the first item in the Sensor + Events setup menu. + + For example, if a new EventSensor is configured as + the 2nd entry AFTER the internal EventSensor (if + one exists) in the Sensor Events Setup Menu, then + that EventSensor will be known from then on as + EventSensor 2. All point indeces with esIndexES=2 + will now refer to that particular EventSensor. + " + ::= { esPointConfigTempEntry 1 } + --1.3.6.1.4.1.3052.10.2.2.1.1.1 + +espcTempIndexPoint OBJECT-TYPE + SYNTAX Integer32 (1..64) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The part of the point index that delineates which + sensor on the EventSensor. + + So this combined with espcTempIndexES (which EventSensor) + uniquely defines each point attached to a unit within the + context of temperature point configuration." + ::= { esPointConfigTempEntry 2 } + --1.3.6.1.4.1.3052.10.2.2.1.1.2 + +espcTempEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF enable this temperature sensor" + ::= { esPointConfigTempEntry 3 } + --1.3.6.1.4.1.3052.10.2.2.1.1.3 + +espcTempScale OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Scale (C/F) for this temperature sensor" + ::= { esPointConfigTempEntry 4 } + --1.3.6.1.4.1.3052.10.2.2.1.1.4 + +espcTempDeadband OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Deadband for this temperature sensor (in floating-point format)" + ::= { esPointConfigTempEntry 5 } + --1.3.6.1.4.1.3052.10.2.2.1.1.5 + +espcTempVHighTemp OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Very high temperature event threshold for this temperature + sensor (in floating-point format)" + ::= { esPointConfigTempEntry 6 } + --1.3.6.1.4.1.3052.10.2.2.1.1.6 + +espcTempVHighActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Very high temperature event actions for this temperature + sensor" + ::= { esPointConfigTempEntry 7 } + --1.3.6.1.4.1.3052.10.2.2.1.1.7 + +espcTempVHighTrapnum OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Very high temperature event trap number for this + temperature sensor" + ::= { esPointConfigTempEntry 8 } + --1.3.6.1.4.1.3052.10.2.2.1.1.8 + +espcTempVHighClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Very high temperature event class for this temperature + sensor" + ::= { esPointConfigTempEntry 9 } + --1.3.6.1.4.1.3052.10.2.2.1.1.9 + +espcTempHighTemp OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "High temperature event threshold for this temperature + sensor (in floating-point format)" + ::= { esPointConfigTempEntry 10 } + --1.3.6.1.4.1.3052.10.2.2.1.1.10 + +espcTempHighActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "High temperature event actions for this temperature sensor" + ::= { esPointConfigTempEntry 11 } + --1.3.6.1.4.1.3052.10.2.2.1.1.11 + +espcTempHighTrapnum OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "High temperature event trap number for this temperature + sensor" + ::= { esPointConfigTempEntry 12 } + --1.3.6.1.4.1.3052.10.2.2.1.1.12 + +espcTempHighClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "High temperature event class for this temperature sensor" + ::= { esPointConfigTempEntry 13 } + --1.3.6.1.4.1.3052.10.2.2.1.1.13 + +espcTempNormalActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Return-to-normal event actions for this temperature sensor" + ::= { esPointConfigTempEntry 14 } + --1.3.6.1.4.1.3052.10.2.2.1.1.14 + +espcTempNormalTrapnum OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Return-to-normal event trap number for this temperature + sensor" + ::= { esPointConfigTempEntry 15 } + --1.3.6.1.4.1.3052.10.2.2.1.1.15 + +espcTempNormalClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Return-to-normal event class for this temperature sensor" + ::= { esPointConfigTempEntry 16 } + --1.3.6.1.4.1.3052.10.2.2.1.1.16 + +espcTempLowTemp OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Low temperature event threshold for this temperature sensor + (in floating-point format)" + ::= { esPointConfigTempEntry 17 } + --1.3.6.1.4.1.3052.10.2.2.1.1.17 + +espcTempLowActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Low temperature event actions for this temperature sensor" + ::= { esPointConfigTempEntry 18 } + --1.3.6.1.4.1.3052.10.2.2.1.1.18 + +espcTempLowTrapnum OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Low temperature event trap number for this temperature + sensor" + ::= { esPointConfigTempEntry 19 } + --1.3.6.1.4.1.3052.10.2.2.1.1.19 + +espcTempLowClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Low temperature event class for this temperature sensor" + ::= { esPointConfigTempEntry 20 } + --1.3.6.1.4.1.3052.10.2.2.1.1.20 + +espcTempVLowTemp OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Very Low temperature event threshold for this temperature + sensor (in floating-point format)" + ::= { esPointConfigTempEntry 21 } + --1.3.6.1.4.1.3052.10.2.2.1.1.21 + +espcTempVLowActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Very Low temperature event actions for this temperature + sensor" + ::= { esPointConfigTempEntry 22 } + --1.3.6.1.4.1.3052.10.2.2.1.1.22 + +espcTempVLowTrapnum OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Very Low temperature event trap number for this temperature + sensor" + ::= { esPointConfigTempEntry 23 } + --1.3.6.1.4.1.3052.10.2.2.1.1.23 + +espcTempVLowClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Very Low temperature event class for this temperature sensor" + ::= { esPointConfigTempEntry 24 } + --1.3.6.1.4.1.3052.10.2.2.1.1.24 + +espcTempGroup OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Name for this temperature sensor group" + ::= { esPointConfigTempEntry 25 } + --1.3.6.1.4.1.3052.10.2.2.1.1.25 + +esPointConfigCCTable OBJECT-TYPE + SYNTAX SEQUENCE OF ESPointConfigCC + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table organizes 3 basic attributes of contact closure + points. A point is a particular sensor on an EventSensor. + The 3 point attributes organizes in this table are: + 1. the configuration item (e.g., enable, name, etc.) + 2. the eventsensor on which this point resides + 3. the point number + + Points are referenced by a point config index. The point + config index is a string of 2 numbers separated by a period. + It contains all the information necessary for getting a piece + of data off an event sensor within the context of this + contact closure point config table ; namely, which + EventSensor and which sensor. + " + ::= { eventSensorPointConfig 2 } + --1.3.6.1.4.1.3052.10.2.2.2 + +esPointConfigCCEntry OBJECT-TYPE + SYNTAX ESPointConfigCC + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry for EventSensor point config contact closure table" + INDEX { espcCCIndexES, espcCCIndexPoint } + ::= { esPointConfigCCTable 1 } + --1.3.6.1.4.1.3052.10.2.2.2.1 + +espcCCIndexES OBJECT-TYPE + SYNTAX Integer32 (1..200) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The part of the point index that refers to an + EventSensor. + + The point config index is a string of 2 numbers separated + by a period. It contains all the information + necessary for getting a piece of data off an event + sensor within the the context of the eventsensor point + config contact closure table; namely, which EventSensor + and which sensor (a.k.a. point). + + This object's allowable values are 1 through 16, + and 200. 200 always refers to the EventSensor + inside the unit. 1 through 16 refer to additional + attached EventSensors. + " + ::= { esPointConfigCCEntry 1 } + --1.3.6.1.4.1.3052.10.2.2.2.1.1 + +espcCCIndexPoint OBJECT-TYPE + SYNTAX Integer32 (1..64) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The part of the point index that delineates which + sensor on the EventSensor. + + So this combined with espcCCIndexES (which EventSensor) + uniquely defines each point attached to a unit within the + context of contact closure point configuration." + ::= { esPointConfigCCEntry 2 } + --1.3.6.1.4.1.3052.10.2.2.2.1.2 + +espcCCEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF enable for this contact closure" + ::= { esPointConfigCCEntry 3 } + --1.3.6.1.4.1.3052.10.2.2.2.1.3 + +espcCCName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Name for this contact closure" + ::= { esPointConfigCCEntry 4 } + --1.3.6.1.4.1.3052.10.2.2.2.1.4 + +espcCCEventState OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Event state for this contact closure" + ::= { esPointConfigCCEntry 5 } + --1.3.6.1.4.1.3052.10.2.2.2.1.5 + +espcCCThreshold OBJECT-TYPE + SYNTAX Integer32 (0..65535) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Event threshold (seconds) for this contact closure" + ::= { esPointConfigCCEntry 6 } + --1.3.6.1.4.1.3052.10.2.2.2.1.6 + +espcCCEventActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Event actions for this contact closure" + ::= { esPointConfigCCEntry 7 } + --1.3.6.1.4.1.3052.10.2.2.2.1.7 + +espcCCEventTrapnum OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Event trap number for this contact closure" + ::= { esPointConfigCCEntry 8 } + --1.3.6.1.4.1.3052.10.2.2.2.1.8 + +espcCCEventClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Event class for this contact closure" + ::= { esPointConfigCCEntry 9 } + --1.3.6.1.4.1.3052.10.2.2.2.1.9 + +espcCCNormalActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Return-to-normal actions for this contact closure" + ::= { esPointConfigCCEntry 10 } + --1.3.6.1.4.1.3052.10.2.2.2.1.10 + +espcCCNormalTrapnum OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Return-to-normal trap number for this contact closure" + ::= { esPointConfigCCEntry 11 } + --1.3.6.1.4.1.3052.10.2.2.2.1.11 + +espcCCNormalClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Return-to-normal class for this contact closure" + ::= { esPointConfigCCEntry 12 } + --1.3.6.1.4.1.3052.10.2.2.2.1.12 + +espcCCAlarmAlias OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Event alias for this contact closure" + ::= { esPointConfigCCEntry 13 } + --1.3.6.1.4.1.3052.10.2.2.2.1.13 + +espcCCNormalAlias OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Return-to-normal alias for this contact closure" + ::= { esPointConfigCCEntry 14 } + --1.3.6.1.4.1.3052.10.2.2.2.1.14 + +espcCCNormalThreshold OBJECT-TYPE + SYNTAX Integer32 (0..65535) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Event threshold (seconds) for this contact closure to return to normal" + ::= { esPointConfigCCEntry 15 } + --1.3.6.1.4.1.3052.10.2.2.2.1.15 + +espcCCOverrideGlobalReminder OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Override global reminder interval (evReminderInterval) for this CC." + ::= { esPointConfigCCEntry 16 } + --1.3.6.1.4.1.3052.10.2.2.2.1.16 + +espcCCReminderInterval OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Individual reminder interval for this CC, applicable when the global + reminder is overriden." + ::= { esPointConfigCCEntry 17 } + --1.3.6.1.4.1.3052.10.2.2.2.1.17 + +espcCCGroup OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Name for this contact closure group" + ::= { esPointConfigCCEntry 18 } + --1.3.6.1.4.1.3052.10.2.2.2.1.18 + +esPointConfigHumidTable OBJECT-TYPE + SYNTAX SEQUENCE OF ESPointConfigHumid + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table organizes 3 basic attributes of humidity points. + A point is a particular sensor on an EventSensor. The 3 + point attributes organizes in this table are: + 1. the configuration item (e.g., enable, name, etc.) + 2. the eventsensor on which this point resides + 3. the point number (always 1 for humidity sensors) + + Points are referenced by a point config index. The point + config index is a string of 2 numbers separated by a period. + It contains all the information necessary for getting a piece + of data off an event sensor within the context of this + humidity point config table ; namely, which EventSensor and + which sensor. + " + ::= { eventSensorPointConfig 3 } + --1.3.6.1.4.1.3052.10.2.2.3 + +esPointConfigHumidEntry OBJECT-TYPE + SYNTAX ESPointConfigHumid + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry for EventSensor point config humidity table" + INDEX { espcHumidIndexES, espcHumidIndexPoint } + ::= { esPointConfigHumidTable 1 } + --1.3.6.1.4.1.3052.10.2.2.3.1 + +espcHumidIndexES OBJECT-TYPE + SYNTAX Integer32 (1..200) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The part of the point index that refers to an + EventSensor. + + The point config index is a string of 2 numbers separated + by a period. It contains all the information + necessary for getting a piece of data off an event + sensor within the the context of the eventsensor point + config contact closure table; namely, which EventSensor + and which sensor (a.k.a. point). + + This object's allowable values are 1 through 16, + and 200. 200 always refers to the EventSensor + inside the unit. 1 through 16 refer to additional + attached EventSensors. + " + ::= { esPointConfigHumidEntry 1 } + --1.3.6.1.4.1.3052.10.2.2.3.1.1 + +espcHumidIndexPoint OBJECT-TYPE + SYNTAX Integer32 (1..64) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The part of the point index that delineates which + sensor on the EventSensor. + + So this combined with espcHumidIndexES (which EventSensor) + uniquely defines each point attached to a unit within the + context of contact closure point configuration." + ::= { esPointConfigHumidEntry 2 } + --1.3.6.1.4.1.3052.10.2.2.3.1.2 + +espcHumidEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF enable for this humidity sensor" + ::= { esPointConfigHumidEntry 3 } + --1.3.6.1.4.1.3052.10.2.2.3.1.3 + +espcHumidDeadband OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Deadband for this humidity sensor" + ::= { esPointConfigHumidEntry 4 } + --1.3.6.1.4.1.3052.10.2.2.3.1.4 + +espcHumidVHighHumid OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Very high event threshold for this humidity sensor" + ::= { esPointConfigHumidEntry 5 } + --1.3.6.1.4.1.3052.10.2.2.3.1.5 + +espcHumidVHighActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Very high event actions for this humidity sensor" + ::= { esPointConfigHumidEntry 6 } + --1.3.6.1.4.1.3052.10.2.2.3.1.6 + +espcHumidVHighTrapnum OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Very high event trap number for this humidity sensor" + ::= { esPointConfigHumidEntry 7 } + --1.3.6.1.4.1.3052.10.2.2.3.1.7 + +espcHumidVHighClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Very high event class for this humidity sensor" + ::= { esPointConfigHumidEntry 8 } + --1.3.6.1.4.1.3052.10.2.2.3.1.8 + +espcHumidHighHumid OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "High event threshold for this humidity sensor" + ::= { esPointConfigHumidEntry 9 } + --1.3.6.1.4.1.3052.10.2.2.3.1.9 + +espcHumidHighActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "High event actions for this humidity sensor" + ::= { esPointConfigHumidEntry 10 } + --1.3.6.1.4.1.3052.10.2.2.3.1.10 + +espcHumidHighTrapnum OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "High event trap number for this humidity sensor" + ::= { esPointConfigHumidEntry 11 } + --1.3.6.1.4.1.3052.10.2.2.3.1.11 + +espcHumidHighClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "High event class for this humidity sensor" + ::= { esPointConfigHumidEntry 12 } + --1.3.6.1.4.1.3052.10.2.2.3.1.12 + +espcHumidNormalActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Return-to-normal actions for this humidity sensor" + ::= { esPointConfigHumidEntry 13 } + --1.3.6.1.4.1.3052.10.2.2.3.1.13 + +espcHumidNormalTrapnum OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Return-to-normal trap number for this humidity sensor" + ::= { esPointConfigHumidEntry 14 } + --1.3.6.1.4.1.3052.10.2.2.3.1.14 + +espcHumidNormalClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Return-to-normal class for this humidity sensor" + ::= { esPointConfigHumidEntry 15 } + --1.3.6.1.4.1.3052.10.2.2.3.1.15 + +espcHumidLowHumid OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Low event threshold for this humidity sensor" + ::= { esPointConfigHumidEntry 16 } + --1.3.6.1.4.1.3052.10.2.2.3.1.16 + +espcHumidLowActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Low event actions for this humidity sensor" + ::= { esPointConfigHumidEntry 17 } + --1.3.6.1.4.1.3052.10.2.2.3.1.17 + +espcHumidLowTrapnum OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Low event trap number for this humidity sensor" + ::= { esPointConfigHumidEntry 18 } + --1.3.6.1.4.1.3052.10.2.2.3.1.18 + +espcHumidLowClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Low event class for this humidity sensor" + ::= { esPointConfigHumidEntry 19 } + --1.3.6.1.4.1.3052.10.2.2.3.1.19 + +espcHumidVLowHumid OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Very low event threshold for this humidity sensor" + ::= { esPointConfigHumidEntry 20 } + --1.3.6.1.4.1.3052.10.2.2.3.1.20 + +espcHumidVLowActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Very low event actions for this humidity sensor" + ::= { esPointConfigHumidEntry 21 } + --1.3.6.1.4.1.3052.10.2.2.3.1.21 + +espcHumidVLowTrapnum OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Very low event trap number for this humidity sensor" + ::= { esPointConfigHumidEntry 22 } + --1.3.6.1.4.1.3052.10.2.2.3.1.22 + +espcHumidVLowClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Very low event class for this humidity sensor" + ::= { esPointConfigHumidEntry 23 } + --1.3.6.1.4.1.3052.10.2.2.3.1.23 + +espcHumidGroup OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Name for this humidity sensor group" + ::= { esPointConfigHumidEntry 24 } + --1.3.6.1.4.1.3052.10.2.2.3.1.24 + +esPointConfigAITable OBJECT-TYPE + SYNTAX SEQUENCE OF ESPointConfigAnalogInput + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table organizes 3 basic attributes of analog input + points. A point is a particular sensor on an EventSensor. + The 3 point attributes organizes in this table are: + 1. the configuration item (e.g., enable, name, etc.) + 2. the eventsensor on which this point resides + 3. the point number + + Points are referenced by a point config index. The point + config index is a string of 2 numbers separated by a period. + It contains all the information necessary for getting a + piece of data off an event sensor within the context of this + analog input point config table ; namely, which EventSensor + and which sensor. + " + ::= { eventSensorPointConfig 5 } + --1.3.6.1.4.1.3052.10.2.2.5 + +esPointConfigAIEntry OBJECT-TYPE + SYNTAX ESPointConfigAnalogInput + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry for EventSensor point config analog input table" + INDEX { espcHumidIndexES, espcHumidIndexPoint } + ::= { esPointConfigAITable 1 } + --1.3.6.1.4.1.3052.10.2.2.5.1 + +espcAIIndexES OBJECT-TYPE + SYNTAX Integer32 (1..200) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The part of the point index that refers to an + EventSensor. + + The point config index is a string of 2 numbers separated + by a period. It contains all the information + necessary for getting a piece of data off an event + sensor within the the context of the eventsensor point + config contact closure table; namely, which EventSensor + and which sensor (a.k.a. point). + + This object's allowable values are 1 through 16, + and 200. 200 always refers to the EventSensor + inside the unit. 1 through 16 refer to additional + attached EventSensors. + " + ::= { esPointConfigAIEntry 1 } + --1.3.6.1.4.1.3052.10.2.2.5.1.1 + +espcAIIndexPoint OBJECT-TYPE + SYNTAX Integer32 (1..64) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The part of the point index that delineates which + sensor on the EventSensor. + + So this combined with espcAIIndexES (which EventSensor) + uniquely defines each point attached to a unit within the + context of contact closure point configuration." + ::= { esPointConfigAIEntry 2 } + --1.3.6.1.4.1.3052.10.2.2.5.1.2 + +espcAIEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF for this analog input sensor" + ::= { esPointConfigAIEntry 3 } + --1.3.6.1.4.1.3052.10.2.2.5.1.3 + +espcAIDeadband OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Deadband for this analog input sensor" + ::= { esPointConfigAIEntry 5 } + --1.3.6.1.4.1.3052.10.2.2.5.1.5 + +espcAIVhighValue OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Very high event threshold (decivolts or tenths of + milliamps) for this analog input sensor" + ::= { esPointConfigAIEntry 6 } + --1.3.6.1.4.1.3052.10.2.2.5.1.6 + +espcAIVhighActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Very high event actions for this analog input sensor" + ::= { esPointConfigAIEntry 7 } + --1.3.6.1.4.1.3052.10.2.2.5.1.7 + +espcAIVhighTrapnum OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Very high event trap number for this analog input sensor" + ::= { esPointConfigAIEntry 8 } + --1.3.6.1.4.1.3052.10.2.2.5.1.8 + +espcAIVhighClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Very high event class for this analog input sensor" + ::= { esPointConfigAIEntry 9 } + --1.3.6.1.4.1.3052.10.2.2.5.1.9 + +espcAIHighValue OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "High event threshold (decivolts or tenths of milliamps) for + this analog input sensor" + ::= { esPointConfigAIEntry 10 } + --1.3.6.1.4.1.3052.10.2.2.5.1.10 + +espcAIHighActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "High event actions for this analog input sensor" + ::= { esPointConfigAIEntry 11 } + --1.3.6.1.4.1.3052.10.2.2.5.1.11 + +espcAIHighTrapnum OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "High event trap number for this analog input sensor" + ::= { esPointConfigAIEntry 12 } + --1.3.6.1.4.1.3052.10.2.2.5.1.12 + +espcAIHighClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "High event class for this analog input sensor" + ::= { esPointConfigAIEntry 13 } + --1.3.6.1.4.1.3052.10.2.2.5.1.13 + +espcAINormalActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Return-to-normal actions for this analog input sensor" + ::= { esPointConfigAIEntry 14 } + --1.3.6.1.4.1.3052.10.2.2.5.1.14 + +espcAINormalTrapnum OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Return-to-normal trap number for this analog input sensor" + ::= { esPointConfigAIEntry 15 } + --1.3.6.1.4.1.3052.10.2.2.5.1.15 + +espcAINormalClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Return-to-normal class for this analog input sensor" + ::= { esPointConfigAIEntry 16 } + --1.3.6.1.4.1.3052.10.2.2.5.1.16 + +espcAILowValue OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Low event threshold (decivolts or tenths of milliamps) for + this analog input sensor" + ::= { esPointConfigAIEntry 17 } + --1.3.6.1.4.1.3052.10.2.2.5.1.17 + +espcAILowActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Low event actions for this analog input sensor" + ::= { esPointConfigAIEntry 18 } + --1.3.6.1.4.1.3052.10.2.2.5.1.18 + +espcAILowTrapnum OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Low event trap number for this analog input sensor" + ::= { esPointConfigAIEntry 19 } + --1.3.6.1.4.1.3052.10.2.2.5.1.19 + +espcAILowClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Low event class for this analog input sensor" + ::= { esPointConfigAIEntry 20 } + --1.3.6.1.4.1.3052.10.2.2.5.1.20 + +espcAIVlowValue OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Very low event threshold (decivolts or tenths of milliamps) + for this analog input sensor" + ::= { esPointConfigAIEntry 21 } + --1.3.6.1.4.1.3052.10.2.2.5.1.21 + +espcAIVlowActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Very low event actions for this analog input sensor" + ::= { esPointConfigAIEntry 22 } + --1.3.6.1.4.1.3052.10.2.2.5.1.22 + +espcAIVlowTrapnum OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Very low event actions for this analog input sensor" + ::= { esPointConfigAIEntry 23 } + --1.3.6.1.4.1.3052.10.2.2.5.1.23 + +espcAIVlowClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Very low event class for this analog input sensor" + ::= { esPointConfigAIEntry 24 } + --1.3.6.1.4.1.3052.10.2.2.5.1.24 + +espcAIConvUnitName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Converstion unit name for this analog input sensor" + ::= { esPointConfigAIEntry 25 } + --1.3.6.1.4.1.3052.10.2.2.5.1.25 + +espcAIConvHighValue OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Conversion high value for this analog input sensor" + ::= { esPointConfigAIEntry 26 } + --1.3.6.1.4.1.3052.10.2.2.5.1.26 + +espcAIConvHighUnit OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Conversion high unit value for this analog input sensor" + ::= { esPointConfigAIEntry 27 } + --1.3.6.1.4.1.3052.10.2.2.5.1.27 + +espcAIConvLowValue OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Conversion low value for this analog input sensor" + ::= { esPointConfigAIEntry 29 } + --1.3.6.1.4.1.3052.10.2.2.5.1.29 + +espcAIConvLowUnit OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Conversion unit low unit value for this analog input sensor" + ::= { esPointConfigAIEntry 30 } + --1.3.6.1.4.1.3052.10.2.2.5.1.30 + +espcAIDisplayFormat OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Analog input display format" + ::= { esPointConfigAIEntry 32 } + --1.3.6.1.4.1.3052.10.2.2.5.1.32 + +espcAIGroup OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Name for this Analog input group" + ::= { esPointConfigAIEntry 33 } + --1.3.6.1.4.1.3052.10.2.2.5.1.33 + +esPointConfigOutputTable OBJECT-TYPE + SYNTAX SEQUENCE OF ESPointConfigOutput + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table organizes configuration items for output + points. A point is a particular sensor on an EventSensor. + The 3 point attributes organized in this table are: + 1. the configuration item (e.g., enable, name, etc.) + 2. the eventsensor on which this point resides + 3. the point number + + Points are referenced by a point config index. The point + config index is a string of 2 numbers separated by a period. + It contains all the information necessary for getting a + piece of data off an event sensor within the context of this + output config table ; namely, which EventSensor + and which sensor. + " + ::= { eventSensorPointConfig 6 } + --1.3.6.1.4.1.3052.10.2.2.6 + +esPointConfigOutputEntry OBJECT-TYPE + SYNTAX ESPointConfigOutput + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry for EventSensor point config output table" + INDEX { espcOutputIndexES, espcOutputIndexPoint } + ::= { esPointConfigOutputTable 1 } + --1.3.6.1.4.1.3052.10.2.2.6.1 + +espcOutputIndexES OBJECT-TYPE + SYNTAX Integer32 (1..200) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The part of the point index that refers to an + EventSensor. + + The point config index is a string of 2 numbers separated + by a period. It contains all the information + necessary for getting a piece of data off an event + sensor within the the context of the eventsensor point + config contact closure table; namely, which EventSensor + and which sensor (a.k.a. point). + + This object's allowable values are 1 through 16, + and 200. 200 always refers to the EventSensor + inside the unit. 1 through 16 refer to additional + attached EventSensors. + " + ::= { esPointConfigOutputEntry 1 } + --1.3.6.1.4.1.3052.10.2.2.6.1.1 + +espcOutputIndexPoint OBJECT-TYPE + SYNTAX Integer32 (1..64) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The part of the point index that delineates which + sensor on the EventSensor. + + So this combined with espcOutputIndexES (which EventSensor) + uniquely defines each point attached to a unit within the + context of output point configuration." + ::= { esPointConfigOutputEntry 2 } + --1.3.6.1.4.1.3052.10.2.2.6.1.2 + +espcOutputEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enables the output event for this output. This has no effect + on whether the relay changes state, only on whether a state change + triggers an event." + ::= { esPointConfigOutputEntry 3 } + --1.3.6.1.4.1.3052.10.2.2.6.1.3 + +espcOutputActiveState OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Which state is considered the active state: energized/de-energized." + ::= { esPointConfigOutputEntry 4 } + --1.3.6.1.4.1.3052.10.2.2.6.1.4 + +espcOutputType OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Output type: RELAY, POWER, SSR, TTL." + ::= { esPointConfigOutputEntry 5 } + --1.3.6.1.4.1.3052.10.2.2.6.1.5 + +espcOutputAliasValue OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Output alias corresponding to its event state." + ::= { esPointConfigOutputEntry 6 } + --1.3.6.1.4.1.3052.10.2.2.6.1.6 + +espcOutputAliasColor OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Output color corresponding to its event state." + ::= { esPointConfigOutputEntry 7 } + --1.3.6.1.4.1.3052.10.2.2.6.1.7 + +espcOutputActiveAlias OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Alias for the output active state." + ::= { esPointConfigOutputEntry 10 } + --1.3.6.1.4.1.3052.10.2.2.6.1.10 + +espcOutputActiveColor OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Output color (as rendered in the web UI, in RGB hex format) corresponding + to the output active state." + ::= { esPointConfigOutputEntry 11 } + --1.3.6.1.4.1.3052.10.2.2.6.1.11 + +espcOutputActiveActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Actions for the output active event." + ::= { esPointConfigOutputEntry 12 } + --1.3.6.1.4.1.3052.10.2.2.6.1.12 + +espcOutputActiveTrapnum OBJECT-TYPE + SYNTAX Integer32 (150..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Actions for the output active event." + ::= { esPointConfigOutputEntry 13 } + --1.3.6.1.4.1.3052.10.2.2.6.1.13 + +espcOutputActiveClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Class (severity) for the output active event." + ::= { esPointConfigOutputEntry 14 } + --1.3.6.1.4.1.3052.10.2.2.6.1.14 + +espcOutputInactiveAlias OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Alias for the output inactive state." + ::= { esPointConfigOutputEntry 20 } + --1.3.6.1.4.1.3052.10.2.2.6.1.20 + +espcOutputInactiveColor OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Output color (as rendered in the web UI, in RGB hex format) corresponding + to the output inactive state." + ::= { esPointConfigOutputEntry 21 } + --1.3.6.1.4.1.3052.10.2.2.6.1.21 + +espcOutputInactiveActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Actions for the output inactive event." + ::= { esPointConfigOutputEntry 22 } + --1.3.6.1.4.1.3052.10.2.2.6.1.22 + +espcOutputInactiveTrapnum OBJECT-TYPE + SYNTAX Integer32 (150..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Actions for the output inactive event." + ::= { esPointConfigOutputEntry 23 } + --1.3.6.1.4.1.3052.10.2.2.6.1.23 + +espcOutputInactiveClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Class (severity) for the output inactive event." + ::= { esPointConfigOutputEntry 24 } + --1.3.6.1.4.1.3052.10.2.2.6.1.24 + +espcOutputGroup OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Name for this Ouput Group" + ::= { esPointConfigOutputEntry 25 } + --1.3.6.1.4.1.3052.10.2.2.6.1.25 + +--*************************************************************************************** +--Serial Port Section 2.3 +--*************************************************************************************** + +numberPorts OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of RS-232 ports found. + Range: 2 or 4" + ::= { serialPorts 1 } + --1.3.6.1.4.1.3052.10.2.3.1 + +portConfigTable OBJECT-TYPE + SYNTAX SEQUENCE OF PortConfig + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Port config table" + ::= { serialPorts 2 } + --1.3.6.1.4.1.3052.10.2.3.2 + +portConfigEntry OBJECT-TYPE + SYNTAX PortConfig + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Port config entry" + INDEX { portConfigIndex } + ::= { portConfigTable 1 } + --1.3.6.1.4.1.3052.10.2.3.2.1 + +portConfigIndex OBJECT-TYPE + SYNTAX Integer32 (1..16) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Index for ports" + ::= { portConfigEntry 1 } + --1.3.6.1.4.1.3052.10.2.3.2.1.1 + +portConfigBaud OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Baud rate, 19200, 9600, etc." + ::= { portConfigEntry 2 } + --1.3.6.1.4.1.3052.10.2.3.2.1.2 + +portConfigDataFormat OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Value representing word length, parity, and + stop bits: 0=8N1, 1=7E1, 2=7O1, 3=7N1, 4=8O2" + ::= { portConfigEntry 3 } + --1.3.6.1.4.1.3052.10.2.3.2.1.3 + +portConfigStripPtOutputLfs OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Strip passthrough LFs sent to device on this port: + 1=yes, 0=no." + ::= { portConfigEntry 4 } + --1.3.6.1.4.1.3052.10.2.3.2.1.4 + +portConfigStripPtInputLfs OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Strip passthrough LFs received from device on this + port: 1=yes, 0=no." + ::= { portConfigEntry 5 } + --1.3.6.1.4.1.3052.10.2.3.2.1.5 + +portConfigMaskEnable OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "1=Use the character mask on this port. 0=Do + not use the mask. When the mask is enabled, + the following ASCII characters are ignored + on the port: + 0, 1, 4-9, 11, 12, 14-31, 128-255. + When the mask is disabled, all characters are + accepted on the port." + ::= { portConfigEntry 7 } + --1.3.6.1.4.1.3052.10.2.3.2.1.7 + +portConfigDAEnable OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "1=Enable the Data Alarm Evaluator for data + on this port. 0=Do not evaluate data on this + port." + ::= { portConfigEntry 8 } + --1.3.6.1.4.1.3052.10.2.3.2.1.8 + +portConfigStoreAlarmsDPT OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF: store alarms received during passthrough" + ::= { portConfigEntry 9 } + --1.3.6.1.4.1.3052.10.2.3.2.1.9 + +portConfigRecordTimeout OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Timeout after last unterminated data received upon + which data collected so far is stored as a record." + ::= { portConfigEntry 10 } + --1.3.6.1.4.1.3052.10.2.3.2.1.10 + +portConfigDataType OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "How the port interprets incoming data: ASCII/BINARY" + ::= { portConfigEntry 11 } + --1.3.6.1.4.1.3052.10.2.3.2.1.11 + +portConfigEtxToCRLF OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF whether the port translates incoming ETX to CRLF" + ::= { portConfigEntry 12 } + --1.3.6.1.4.1.3052.10.2.3.2.1.12 + +portConfigMLREnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF Whether Multiline Records are collected on this port." + ::= { portConfigEntry 13 } + --1.3.6.1.4.1.3052.10.2.3.2.1.13 + +portConfigMLRStartField1Pos OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Position of MLR start field 1" + ::= { portConfigEntry 14 } + --1.3.6.1.4.1.3052.10.2.3.2.1.14 + +portConfigMLRStartField1Text OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Text to match MLR start field 1" + ::= { portConfigEntry 15 } + --1.3.6.1.4.1.3052.10.2.3.2.1.15 + +portConfigMLRStartField2Pos OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Position of MLR start field 2" + ::= { portConfigEntry 16 } + --1.3.6.1.4.1.3052.10.2.3.2.1.16 + +portConfigMLRStartField2Text OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Text to match MLR start field 2" + ::= { portConfigEntry 17 } + --1.3.6.1.4.1.3052.10.2.3.2.1.17 + +portConfigMLRNumLinesBefore OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Number of lines before the starting line which should + be included in the MLR" + ::= { portConfigEntry 18 } + --1.3.6.1.4.1.3052.10.2.3.2.1.18 + +portConfigMLREndDetection OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "How the MLR parser determines what ends an MLR: by FORMULA, + number of lines received so far (COUNT), or number of blank + lines received so far (BLANKS)" + ::= { portConfigEntry 19 } + --1.3.6.1.4.1.3052.10.2.3.2.1.19 + +portConfigMLRLineCount OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Number of lines in the MLR (used by the end detection mode)" + ::= { portConfigEntry 20 } + --1.3.6.1.4.1.3052.10.2.3.2.1.20 + +portConfigMLREndField1Pos OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Position of MLR end field 1" + ::= { portConfigEntry 21 } + --1.3.6.1.4.1.3052.10.2.3.2.1.21 + +portConfigMLREndField1Text OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Text to match MLR end field 1" + ::= { portConfigEntry 22 } + --1.3.6.1.4.1.3052.10.2.3.2.1.22 + +portConfigMLREndField2Pos OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Position of MLR end field 2" + ::= { portConfigEntry 23 } + --1.3.6.1.4.1.3052.10.2.3.2.1.23 + +portConfigMLREndField2Text OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Text to match MLR end field 2" + ::= { portConfigEntry 24 } + --1.3.6.1.4.1.3052.10.2.3.2.1.24 + +portConfigMLRUseComplexRules OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF MLR parser uses complex rules (field possitions/ + formulas, etc.)" + ::= { portConfigEntry 25 } + --1.3.6.1.4.1.3052.10.2.3.2.1.25 + +portConfigBufferPT OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF records received during passthrough mode are + buffered/stored in the database" + ::= { portConfigEntry 26 } + --1.3.6.1.4.1.3052.10.2.3.2.1.26 + +portConfigId OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The text identifer for the port" + ::= { portConfigEntry 27 } + --1.3.6.1.4.1.3052.10.2.3.2.1.27 + +portConfigMode OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Mode of the serial port." + ::= { portConfigEntry 28 } + --1.3.6.1.4.1.3052.10.2.3.2.1.28 + +portConfigHsk OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Handshaking mode of the serial port." + ::= { portConfigEntry 29 } + --1.3.6.1.4.1.3052.10.2.3.2.1.29 + + +--*************************************************************************************** +--Network Section 2.4 +--*************************************************************************************** + +eth1Mode OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Mode of the Ethernet1 interface: STATIC,DHCP,VLAN" + ::= { ethernet1 1 } + --1.3.6.1.4.1.3052.10.2.4.1.1.1.1 + +eth1Address OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Ethernet1 IP address" + ::= { ethernet1 2 } + --1.3.6.1.4.1.3052.10.2.4.1.1.1.2 + +eth1SubnetMask OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Ethernet1 subnet mask" + ::= { ethernet1 3 } + --1.3.6.1.4.1.3052.10.2.4.1.1.1.3 + +eth1Router OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Ethernet1 router" + ::= { ethernet1 4 } + --1.3.6.1.4.1.3052.10.2.4.1.1.1.4 + +-- Ethernet1 VLAN1 + +eth1VLAN1ID OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Ethernet1 VLAN1 ID" + ::= { eth1VLAN1 1 } + --1.3.6.1.4.1.3052.10.2.4.1.1.1.5.1.1 + +eth1VLAN1Priority OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Ethernet1 VLAN1 priority" + ::= { eth1VLAN1 2 } + --1.3.6.1.4.1.3052.10.2.4.1.1.1.5.1.2 + +eth1VLAN1Address OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Ethernet1 VLAN1 IP address" + ::= { eth1VLAN1 3 } + --1.3.6.1.4.1.3052.10.2.4.1.1.1.5.1.3 + +eth1VLAN1SubnetMask OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Ethernet1 VLAN1 subnet mask" + ::= { eth1VLAN1 4 } + --1.3.6.1.4.1.3052.10.2.4.1.1.1.5.1.4 + +eth1VLAN1Router OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Ethernet1 VLAN1 router" + ::= { eth1VLAN1 5 } + --1.3.6.1.4.1.3052.10.2.4.1.1.1.5.1.5 + +-- Ethernet1 VLAN2 + +eth1VLAN2ID OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Ethernet1 VLAN2 ID" + ::= { eth1VLAN2 1 } + --1.3.6.1.4.1.3052.10.2.4.1.1.1.5.2.1 + +eth1VLAN2Priority OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Ethernet1 VLAN2 priority" + ::= { eth1VLAN2 2 } + --1.3.6.1.4.1.3052.10.2.4.1.1.1.5.2.2 + +eth1VLAN2Address OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Ethernet1 VLAN2 IP address" + ::= { eth1VLAN2 3 } + --1.3.6.1.4.1.3052.10.2.4.1.1.1.5.2.3 + +eth1VLAN2SubnetMask OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Ethernet1 VLAN2 subnet mask" + ::= { eth1VLAN2 4 } + --1.3.6.1.4.1.3052.10.2.4.1.1.1.5.2.4 + +eth1VLAN2Router OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Ethernet1 VLAN2 router" + ::= { eth1VLAN2 5 } + --1.3.6.1.4.1.3052.10.2.4.1.1.1.5.2.5 + +-- Ethernet1 VLAN3 + +eth1VLAN3ID OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Ethernet1 VLAN3 ID" + ::= { eth1VLAN3 1 } + --1.3.6.1.4.1.3052.10.2.4.1.1.1.5.3.1 + +eth1VLAN3Priority OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Ethernet1 VLAN3 priority" + ::= { eth1VLAN3 2 } + --1.3.6.1.4.1.3052.10.2.4.1.1.1.5.3.2 + +eth1VLAN3Address OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Ethernet1 VLAN3 IP address" + ::= { eth1VLAN3 3 } + --1.3.6.1.4.1.3052.10.2.4.1.1.1.5.3.3 + +eth1VLAN3SubnetMask OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Ethernet1 VLAN3 subnet mask" + ::= { eth1VLAN3 4 } + --1.3.6.1.4.1.3052.10.2.4.1.1.1.5.3.4 + +eth1VLAN3Router OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Ethernet1 VLAN3 router" + ::= { eth1VLAN3 5 } + --1.3.6.1.4.1.3052.10.2.4.1.1.1.5.3.5 + +-- Ethernet1 VLAN4 + +eth1VLAN4ID OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Ethernet1 VLAN4 ID" + ::= { eth1VLAN4 1 } + --1.3.6.1.4.1.3052.10.2.4.1.1.1.5.4.1 + +eth1VLAN4Priority OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Ethernet1 VLAN4 priority" + ::= { eth1VLAN4 2 } + --1.3.6.1.4.1.3052.10.2.4.1.1.1.5.4.2 + +eth1VLAN4Address OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Ethernet1 VLAN4 IP address" + ::= { eth1VLAN4 3 } + --1.3.6.1.4.1.3052.10.2.4.1.1.1.5.4.3 + +eth1VLAN4SubnetMask OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Ethernet1 VLAN4 subnet mask" + ::= { eth1VLAN4 4 } + --1.3.6.1.4.1.3052.10.2.4.1.1.1.5.4.4 + +eth1VLAN4Router OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Ethernet1 VLAN4 router" + ::= { eth1VLAN4 5 } + --1.3.6.1.4.1.3052.10.2.4.1.1.1.5.4.5 + +-- Ethernet1 VLAN5 + +eth1VLAN5ID OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Ethernet1 VLAN5 ID" + ::= { eth1VLAN5 1 } + --1.3.6.1.4.1.3052.10.2.4.1.1.1.5.5.1 + +eth1VLAN5Priority OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Ethernet1 VLAN5 priority" + ::= { eth1VLAN5 2 } + --1.3.6.1.4.1.3052.10.2.4.1.1.1.5.5.2 + +eth1VLAN5Address OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Ethernet1 VLAN5 IP address" + ::= { eth1VLAN5 3 } + --1.3.6.1.4.1.3052.10.2.4.1.1.1.5.5.3 + +eth1VLAN5SubnetMask OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Ethernet1 VLAN5 subnet mask" + ::= { eth1VLAN5 4 } + --1.3.6.1.4.1.3052.10.2.4.1.1.1.5.5.4 + +eth1VLAN5Router OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Ethernet1 VLAN5 router" + ::= { eth1VLAN5 5 } + --1.3.6.1.4.1.3052.10.2.4.1.1.1.5.5.5 + +-- Ethernet1 VLAN6 + +eth1VLAN6ID OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Ethernet1 VLAN6 ID" + ::= { eth1VLAN6 1 } + --1.3.6.1.4.1.3052.10.2.4.1.1.1.5.6.1 + +eth1VLAN6Priority OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Ethernet1 VLAN6 priority" + ::= { eth1VLAN6 2 } + --1.3.6.1.4.1.3052.10.2.4.1.1.1.5.6.2 + +eth1VLAN6Address OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Ethernet1 VLAN6 IP address" + ::= { eth1VLAN6 3 } + --1.3.6.1.4.1.3052.10.2.4.1.1.1.5.6.3 + +eth1VLAN6SubnetMask OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Ethernet1 VLAN6 subnet mask" + ::= { eth1VLAN6 4 } + --1.3.6.1.4.1.3052.10.2.4.1.1.1.5.6.4 + +eth1VLAN6Router OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Ethernet1 VLAN6 router" + ::= { eth1VLAN6 5 } + --1.3.6.1.4.1.3052.10.2.4.1.1.1.5.6.5 + +eth1MAC OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Ethernet1 MAC" + ::= { ethernet1 6 } + --1.3.6.1.4.1.3052.10.2.4.1.1.1.6 + +eth1IPv6Mode OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Controls IPv6 operation for this Ethernet interface." + ::= { eth1IPv6 1 } + --1.3.6.1.4.1.3052.10.2.4.1.1.1.7.1 + +eth1IPv6StaticAddress OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "he static IPv6 address to use for this interface when in + operating in STATIC mode." + ::= { eth1IPv6Static 1 } + --1.3.6.1.4.1.3052.10.2.4.1.1.1.7.2.1 + +eth1IPv6StaticRouter OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IPv6 router to engage as the default router when this + interface operates in STATIC mode." + ::= { eth1IPv6Static 2 } + --1.3.6.1.4.1.3052.10.2.4.1.1.1.7.2.1 + +eth1IPv6AutoAddress1 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "One of the automatically-acquired IPv6 addresses." + ::= { eth1IPv6Auto 1 } + --1.3.6.1.4.1.3052.10.2.4.1.1.1.7.3.1 + +eth1IPv6AutoAddress2 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "One of the automatically-acquired IPv6 addresses." + ::= { eth1IPv6Auto 2 } + --1.3.6.1.4.1.3052.10.2.4.1.1.1.7.3.2 + +eth1IPv6AutoAddress3 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "One of the automatically-acquired IPv6 addresses." + ::= { eth1IPv6Auto 3 } + --1.3.6.1.4.1.3052.10.2.4.1.1.1.7.3.3 + +eth1IPv6AutoAddress4 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "One of the automatically-acquired IPv6 addresses." + ::= { eth1IPv6Auto 4 } + --1.3.6.1.4.1.3052.10.2.4.1.1.1.7.3.4 + +eth1IPv6LinkLocalAddress OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The link local IPv6 address for this interface. This is + present when the IPv6 mode is not OFF." + ::= { eth1IPv6 4 } + --1.3.6.1.4.1.3052.10.2.4.1.1.1.7.4 + + + +eth2Mode OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Mode of the Ethernet2 interface: STATIC,DHCP,VLAN" + ::= { ethernet2 1 } + --1.3.6.1.4.1.3052.10.2.4.1.1.2.1 + +eth2Address OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Ethernet2 IP address" + ::= { ethernet2 2 } + --1.3.6.1.4.1.3052.10.2.4.1.1.2.2 + +eth2SubnetMask OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Ethernet2 subnet mask" + ::= { ethernet2 3 } + --1.3.6.1.4.1.3052.10.2.4.1.1.2.3 + +eth2Router OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Ethernet2 router" + ::= { ethernet2 4 } + --1.3.6.1.4.1.3052.10.2.4.1.1.2.4 + + +-- Ethernet2 VLAN1 + +eth2VLAN1ID OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Ethernet2 VLAN1 ID" + ::= { eth2VLAN1 1 } + --1.3.6.1.4.1.3052.10.2.4.1.1.2.5.1.1 + +eth2VLAN1Priority OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Ethernet2 VLAN1 priority" + ::= { eth2VLAN1 2 } + --1.3.6.1.4.1.3052.10.2.4.1.1.2.5.1.2 + +eth2VLAN1Address OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Ethernet2 VLAN1 IP address" + ::= { eth2VLAN1 3 } + --1.3.6.1.4.1.3052.10.2.4.1.1.2.5.1.3 + +eth2VLAN1SubnetMask OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Ethernet2 VLAN1 subnet mask" + ::= { eth2VLAN1 4 } + --1.3.6.1.4.1.3052.10.2.4.1.1.2.5.1.4 + +eth2VLAN1Router OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Ethernet2 VLAN1 router" + ::= { eth2VLAN1 5 } + --1.3.6.1.4.1.3052.10.2.4.1.1.2.5.1.5 + +-- Ethernet2 VLAN2 + +eth2VLAN2ID OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Ethernet2 VLAN2 ID" + ::= { eth2VLAN2 1 } + --1.3.6.1.4.1.3052.10.2.4.1.1.2.5.2.1 + +eth2VLAN2Priority OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Ethernet2 VLAN2 priority" + ::= { eth2VLAN2 2 } + --1.3.6.1.4.1.3052.10.2.4.1.1.2.5.2.2 + +eth2VLAN2Address OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Ethernet2 VLAN2 IP address" + ::= { eth2VLAN2 3 } + --1.3.6.1.4.1.3052.10.2.4.1.1.2.5.2.3 + +eth2VLAN2SubnetMask OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Ethernet2 VLAN2 subnet mask" + ::= { eth2VLAN2 4 } + --1.3.6.1.4.1.3052.10.2.4.1.1.2.5.2.4 + +eth2VLAN2Router OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Ethernet2 VLAN2 router" + ::= { eth2VLAN2 5 } + --1.3.6.1.4.1.3052.10.2.4.1.1.2.5.2.5 + +-- Ethernet2 VLAN3 + +eth2VLAN3ID OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Ethernet2 VLAN3 ID" + ::= { eth2VLAN3 1 } + --1.3.6.1.4.1.3052.10.2.4.1.1.2.5.3.1 + +eth2VLAN3Priority OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Ethernet2 VLAN3 priority" + ::= { eth2VLAN3 2 } + --1.3.6.1.4.1.3052.10.2.4.1.1.2.5.3.2 + +eth2VLAN3Address OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Ethernet2 VLAN3 IP address" + ::= { eth2VLAN3 3 } + --1.3.6.1.4.1.3052.10.2.4.1.1.2.5.3.3 + +eth2VLAN3SubnetMask OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Ethernet2 VLAN3 subnet mask" + ::= { eth2VLAN3 4 } + --1.3.6.1.4.1.3052.10.2.4.1.1.2.5.3.4 + +eth2VLAN3Router OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Ethernet2 VLAN3 router" + ::= { eth2VLAN3 5 } + --1.3.6.1.4.1.3052.10.2.4.1.1.2.5.3.5 + +-- Ethernet2 VLAN4 + +eth2VLAN4ID OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Ethernet2 VLAN4 ID" + ::= { eth2VLAN4 1 } + --1.3.6.1.4.1.3052.10.2.4.1.1.2.5.4.1 + +eth2VLAN4Priority OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Ethernet2 VLAN4 priority" + ::= { eth2VLAN4 2 } + --1.3.6.1.4.1.3052.10.2.4.1.1.2.5.4.2 + +eth2VLAN4Address OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Ethernet2 VLAN4 IP address" + ::= { eth2VLAN4 3 } + --1.3.6.1.4.1.3052.10.2.4.1.1.2.5.4.3 + +eth2VLAN4SubnetMask OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Ethernet2 VLAN4 subnet mask" + ::= { eth2VLAN4 4 } + --1.3.6.1.4.1.3052.10.2.4.1.1.2.5.4.4 + +eth2VLAN4Router OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Ethernet2 VLAN4 router" + ::= { eth2VLAN4 5 } + --1.3.6.1.4.1.3052.10.2.4.1.1.2.5.4.5 + +-- Ethernet2 VLAN5 + +eth2VLAN5ID OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Ethernet2 VLAN5 ID" + ::= { eth2VLAN5 1 } + --1.3.6.1.4.1.3052.10.2.4.1.1.2.5.5.1 + +eth2VLAN5Priority OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Ethernet2 VLAN5 priority" + ::= { eth2VLAN5 2 } + --1.3.6.1.4.1.3052.10.2.4.1.1.2.5.5.2 + +eth2VLAN5Address OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Ethernet2 VLAN5 IP address" + ::= { eth2VLAN5 3 } + --1.3.6.1.4.1.3052.10.2.4.1.1.2.5.5.3 + +eth2VLAN5SubnetMask OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Ethernet2 VLAN5 subnet mask" + ::= { eth2VLAN5 4 } + --1.3.6.1.4.1.3052.10.2.4.1.1.2.5.5.4 + +eth2VLAN5Router OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Ethernet2 VLAN5 router" + ::= { eth2VLAN5 5 } + --1.3.6.1.4.1.3052.10.2.4.1.1.2.5.5.5 + +-- Ethernet2 VLAN6 + +eth2VLAN6ID OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Ethernet2 VLAN6 ID" + ::= { eth2VLAN6 1 } + --1.3.6.1.4.1.3052.10.2.4.1.1.2.5.6.1 + +eth2VLAN6Priority OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Ethernet2 VLAN6 priority" + ::= { eth2VLAN6 2 } + --1.3.6.1.4.1.3052.10.2.4.1.1.2.5.6.2 + +eth2VLAN6Address OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Ethernet2 VLAN6 IP address" + ::= { eth2VLAN6 3 } + --1.3.6.1.4.1.3052.10.2.4.1.1.2.5.6.3 + +eth2VLAN6SubnetMask OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Ethernet2 VLAN6 subnet mask" + ::= { eth2VLAN6 4 } + --1.3.6.1.4.1.3052.10.2.4.1.1.2.5.6.4 + +eth2VLAN6Router OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Ethernet2 VLAN6 router" + ::= { eth2VLAN6 5 } + --1.3.6.1.4.1.3052.10.2.4.1.1.2.5.6.5 + +eth2MAC OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Ethernet2 MAC" + ::= { ethernet2 6 } + --1.3.6.1.4.1.3052.10.2.4.1.1.2.6 + +eth2IPv6Mode OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Controls IPv6 operation for this Ethernet interface." + ::= { eth2IPv6 1 } + --1.3.6.1.4.1.3052.10.2.4.1.1.2.7.1 + +eth2IPv6StaticAddress OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "he static IPv6 address to use for this interface when in + operating in STATIC mode." + ::= { eth2IPv6Static 1 } + --1.3.6.1.4.1.3052.10.2.4.1.1.2.7.2.1 + +eth2IPv6StaticRouter OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IPv6 router to engage as the default router when this + interface operates in STATIC mode." + ::= { eth2IPv6Static 2 } + --1.3.6.1.4.1.3052.10.2.4.1.1.2.7.2.1 + +eth2IPv6AutoAddress1 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "One of the automatically-acquired IPv6 addresses." + ::= { eth2IPv6Auto 1 } + --1.3.6.1.4.1.3052.10.2.4.1.1.2.7.3.1 + +eth2IPv6AutoAddress2 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "One of the automatically-acquired IPv6 addresses." + ::= { eth2IPv6Auto 2 } + --1.3.6.1.4.1.3052.10.2.4.1.1.2.7.3.2 + +eth2IPv6AutoAddress3 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "One of the automatically-acquired IPv6 addresses." + ::= { eth2IPv6Auto 3 } + --1.3.6.1.4.1.3052.10.2.4.1.1.2.7.3.3 + +eth2IPv6AutoAddress4 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "One of the automatically-acquired IPv6 addresses." + ::= { eth2IPv6Auto 4 } + --1.3.6.1.4.1.3052.10.2.4.1.1.2.7.3.4 + +eth2IPv6LinkLocalAddress OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The link local IPv6 address for this interface. This is + present when the IPv6 mode is not OFF." + ::= { eth2IPv6 4 } + --1.3.6.1.4.1.3052.10.2.4.1.1.2.7.4 + + + +defaultRouter OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The default router/gateway" + ::= { network 2 } + --1.3.6.1.4.1.3052.10.2.4.2 + +-- DNS + +dnsTable OBJECT-TYPE + SYNTAX SEQUENCE OF DNSConfig + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "DNS server address table" + ::= { network 3 } + --1.3.6.1.4.1.3052.10.2.4.3 + +dnsEntry OBJECT-TYPE + SYNTAX DNSConfig + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "DNS server address entry" + INDEX { dnsIndex } + ::= { dnsTable 1 } + --1.3.6.1.4.1.3052.10.2.4.3.1 + +dnsIndex OBJECT-TYPE + SYNTAX Integer32 (1..2) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Index for DNS server address" + ::= { dnsEntry 1 } + --1.3.6.1.4.1.3052.10.2.4.3.1.1 + +dnsAddress OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "DNS server address" + ::= { dnsEntry 2 } + --1.3.6.1.4.1.3052.10.2.4.3.1.2 + +hostname OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The hostname of the unit" + ::= { network 4 } + --1.3.6.1.4.1.3052.10.2.4.4 + +hostTable OBJECT-TYPE + SYNTAX SEQUENCE OF HostConfig + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Static host table" + ::= { network 5 } + --1.3.6.1.4.1.3052.10.2.4.5 + +hostEntry OBJECT-TYPE + SYNTAX HostConfig + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Static host entry" + INDEX { hostIndex } + ::= { hostTable 1 } + --1.3.6.1.4.1.3052.10.2.4.5.1 + +hostIndex OBJECT-TYPE + SYNTAX Integer32 (1..2) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Index for static host" + ::= { hostEntry 1 } + --1.3.6.1.4.1.3052.10.2.4.5.1.1 + +hostDeclaration OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Static host declaration string (i.e. 'address hostname')" + ::= { hostEntry 2 } + --1.3.6.1.4.1.3052.10.2.4.5.1.2 + +-- Network Command Processor + +ncpDuplex OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "For network command processor: 1=Input characters are echoed; 0=no echo." + ::= { network 6 } + --1.3.6.1.4.1.3052.10.2.4.6 + +ncpTimeout OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Network command processor inactivity timeout" + ::= { network 7 } + --1.3.6.1.4.1.3052.10.2.4.7 + +-- SNMP + +snmpAgentEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF for snmp agent" + ::= { snmp 1 } + --1.3.6.1.4.1.3052.10.2.4.8.1 + +snmpNotificationCaptureEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF unit receives and stores SNMP traps/informs" + ::= { snmp 5 } + --1.3.6.1.4.1.3052.10.2.4.8.5 + +snmpNotificationCaptureFile OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "File to which unit stores received SNMP traps/informs" + ::= { snmp 6 } + --1.3.6.1.4.1.3052.10.2.4.8.6 + +snmpNtfnAttempts OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Maximum of times the unit attempts to send a notification + (trap/inform) in 1 cycle" + ::= { snmpNotificationTx 1 } + --1.3.6.1.4.1.3052.10.2.4.8.7.1 + +snmpNtfnTimeout OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Number of seconds between retries of sending a notification" + ::= { snmpNotificationTx 2 } + --1.3.6.1.4.1.3052.10.2.4.8.7.2 + +snmpNtfnCycles OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Number of times the unit attempts a group of attempts to send + a notification (a cycle)" + ::= { snmpNotificationTx 3 } + --1.3.6.1.4.1.3052.10.2.4.8.7.3 + +snmpNtfnSnooze OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Minutes between cycles" + ::= { snmpNotificationTx 4 } + --1.3.6.1.4.1.3052.10.2.4.8.7.4 + +-- SNMP proxy + +snmpProxyTable OBJECT-TYPE + SYNTAX SEQUENCE OF SNMPProxyTable + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table of SNMP proxy entries" + ::= { snmpProxy 1 } + --1.3.6.1.4.1.3052.10.2.4.8.8.1 + +snmpProxyEntry OBJECT-TYPE + SYNTAX SNMPProxyTable + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry for SNMP proxy table" + INDEX { snmpProxyIndex } + ::= { snmpProxyTable 1 } + --1.3.6.1.4.1.3052.10.2.4.8.8.1.1 + +snmpProxyIndex OBJECT-TYPE + SYNTAX Integer32 (1..8) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Index for SNMP proxy table" + ::= { snmpProxyEntry 1 } + --1.3.6.1.4.1.3052.10.2.4.8.8.1.1.1 + +snmpProxyEgressOIDBranch OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The OID branch to trigger the proxy function. This should cover + the device to proxy. If blank then this proxy entry is disabled." + ::= { snmpProxyEntry 2 } + --1.3.6.1.4.1.3052.10.2.4.8.8.1.1.2 + +snmpProxyIP OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IP address of the device to proxy." + ::= { snmpProxyEntry 3 } + --1.3.6.1.4.1.3052.10.2.4.8.8.1.1.3 + +snmpProxyPort OBJECT-TYPE + SYNTAX Integer32 (1..65535) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The UDP port on which the device to proxy listens." + ::= { snmpProxyEntry 4 } + --1.3.6.1.4.1.3052.10.2.4.8.8.1.1.4 + +snmpProxyIngressOIDBranch OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The OID branch to be remapped to egress OID branch to trigger the + proxy function. If blank then the egress OID branch is proxied + without remapping." + ::= { snmpProxyEntry 5 } + --1.3.6.1.4.1.3052.10.2.4.8.8.1.1.5 + +snmpProxyName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Name of this proxy entry." + ::= { snmpProxyEntry 6 } + --1.3.6.1.4.1.3052.10.2.4.8.8.1.1.6 + +-- SNMP Poll + +snmpPMode OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Mode of poll operation: OFF, POLL ONLY (just make the results + available to view), or POLL BUFFER (store the results)." + ::= { snmpPoll 1 } + --1.3.6.1.4.1.3052.10.2.4.8.9.1 + +snmpPBufferFile OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "CRDB file in which data is stored." + ::= { snmpPoll 2 } + --1.3.6.1.4.1.3052.10.2.4.8.9.2 + +snmpPBufferAllPeriod OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Period (in seconds) that, if non-zero, all results are buffered + in the CRDB regardless of the threshold." + ::= { snmpPoll 3 } + --1.3.6.1.4.1.3052.10.2.4.8.9.3 + +snmpPRequestTable OBJECT-TYPE + SYNTAX SEQUENCE OF SNMPPollRequestConfig + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table of SNMP Poll requests." + ::= { snmpPoll 4 } + --1.3.6.1.4.1.3052.10.2.4.8.9.4 + +snmpPRequestEntry OBJECT-TYPE + SYNTAX SNMPPollRequestConfig + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry for table pf SNMP Poll requests." + INDEX { snmpPRequestIndex } + ::= { snmpPRequestTable 1 } + --1.3.6.1.4.1.3052.10.2.4.8.9.4.1 + +snmpPRequestIndex OBJECT-TYPE + SYNTAX Integer32 (1..64) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Index for table of SNMP Poll requests." + ::= { snmpPRequestEntry 1 } + --1.3.6.1.4.1.3052.10.2.4.8.9.4.1.1 + +snmpPRequestDescription OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "A description for this single telemetry request; no functional effect." + ::= { snmpPRequestEntry 2 } + --1.3.6.1.4.1.3052.10.2.4.8.9.4.1.2 + +snmpPRequestAgent OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "SNMP Agent IP address or hostname for this single telemetry request." + ::= { snmpPRequestEntry 3 } + --1.3.6.1.4.1.3052.10.2.4.8.9.4.1.3 + +snmpPRequestReadcom OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "SNMP read community for this single telemetry request." + ::= { snmpPRequestEntry 4 } + --1.3.6.1.4.1.3052.10.2.4.8.9.4.1.4 + +snmpPRequestOID OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "SNMP object identifier for this single telemetry request." + ::= { snmpPRequestEntry 5 } + --1.3.6.1.4.1.3052.10.2.4.8.9.4.1.5 + +snmpPRequestPeriod OBJECT-TYPE + SYNTAX Integer32 (1..255) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "How many seconds between periodic SNMP polls of this + single telemetry request." + ::= { snmpPRequestEntry 6 } + --1.3.6.1.4.1.3052.10.2.4.8.9.4.1.6 + +snmpPRequestID OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "A textual field that is part of the record containing + the telemetry result." + ::= { snmpPRequestEntry 7 } + --1.3.6.1.4.1.3052.10.2.4.8.9.4.1.7 + +snmpPRequestThreshold OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Controls when new data is stored upon a successful + telemetry request." + ::= { snmpPRequestEntry 8 } + --1.3.6.1.4.1.3052.10.2.4.8.9.4.1.8 + +snmpPRequestResultStatus OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Status of the last attempt for this telemetry request." + ::= { snmpPRequestEntry 10 } + --1.3.6.1.4.1.3052.10.2.4.8.9.4.1.10 + +snmpPRequestResultValue OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The telemetry value if the last request was successful." + ::= { snmpPRequestEntry 11 } + --1.3.6.1.4.1.3052.10.2.4.8.9.4.1.11 + +snmpPRequestResultTime OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The timestamp of the last telemetry request." + ::= { snmpPRequestEntry 12 } + --1.3.6.1.4.1.3052.10.2.4.8.9.4.1.12 + +snmpPRequestResultType OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The type of the telemetry as reported by the agent." + ::= { snmpPRequestEntry 13 } + --1.3.6.1.4.1.3052.10.2.4.8.9.4.1.13 + + +-- FTP + +ftpPushEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable FTP push for REGULAR (protocol: FTP) or SECURE (protocol: + SFTP) operation, or disable it (OFF)" + ::= { ftpPush 1 } + --1.3.6.1.4.1.3052.10.2.4.9.1 + +ftpPushServer OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "FTP server to which data should be pushed" + ::= { ftpPush 2 } + --1.3.6.1.4.1.3052.10.2.4.9.2 + +ftpPushAccount OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "FTP push account" + ::= { ftpPush 5 } + --1.3.6.1.4.1.3052.10.2.4.9.5 + +ftpPushDirectory OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "FTP push directory" + ::= { ftpPush 6 } + --1.3.6.1.4.1.3052.10.2.4.9.6 + +ftpPushperiod OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Minutes between pushes" + ::= { ftpPush 7 } + --1.3.6.1.4.1.3052.10.2.4.9.7 + +ftpPushPushFileTable OBJECT-TYPE + SYNTAX SEQUENCE OF FTPPushPushFileConfig + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table of files to push" + ::= { ftpPush 8 } + --1.3.6.1.4.1.3052.10.2.4.9.8 + +ftpPushPushFileEntry OBJECT-TYPE + SYNTAX FTPPushPushFileConfig + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry for table of files to push" + INDEX { ftpPushPushFileIndex } + ::= { ftpPushPushFileTable 1 } + --1.3.6.1.4.1.3052.10.2.4.9.8.1 + +ftpPushPushFileIndex OBJECT-TYPE + SYNTAX Integer32 (1..16) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Index for table of files to push" + ::= { ftpPushPushFileEntry 1 } + --1.3.6.1.4.1.3052.10.2.4.9.8.1.1 + +ftpPushPushFile OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF push this local FILEx" + ::= { ftpPushPushFileEntry 2 } + --1.3.6.1.4.1.3052.10.2.4.9.8.1.2 + +ftpPushPushAudit OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF push the audit log" + ::= { ftpPush 9 } + --1.3.6.1.4.1.3052.10.2.4.9.9 + +ftpPushPushAlarms OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF push the alarms/events file" + ::= { ftpPush 10 } + --1.3.6.1.4.1.3052.10.2.4.9.10 + +ftpPushRemoteFileTable OBJECT-TYPE + SYNTAX SEQUENCE OF FTPPushRemoteFileConfig + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table of remote names of files to push" + ::= { ftpPush 11 } + --1.3.6.1.4.1.3052.10.2.4.9.11 + +ftpPushRemoteFileEntry OBJECT-TYPE + SYNTAX FTPPushRemoteFileConfig + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry for table of remote names of files to push" + INDEX { ftpPushRemoteFileIndex } + ::= { ftpPushRemoteFileTable 1 } + --1.3.6.1.4.1.3052.10.2.4.9.11.1 + +ftpPushRemoteFileIndex OBJECT-TYPE + SYNTAX Integer32 (1..16) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Index for table of remote names of files to push" + ::= { ftpPushRemoteFileEntry 1 } + --1.3.6.1.4.1.3052.10.2.4.9.11.1 + +ftpPushRemoteFileName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "remote name of pushed FILEx (name on server)" + ::= { ftpPushRemoteFileEntry 2 } + --1.3.6.1.4.1.3052.10.2.4.9.11.2 + +ftpPushRemoteAlarmName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Filename on server for alarms" + ::= { ftpPush 12 } + --1.3.6.1.4.1.3052.10.2.4.9.12 + +ftpPushPassive OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF use ftp passive mode" + ::= { ftpPush 13 } + --1.3.6.1.4.1.3052.10.2.4.9.13 + +ftpPushIncludeDate OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF include the date in the name of the pushed file" + ::= { ftpPush 14 } + --1.3.6.1.4.1.3052.10.2.4.9.14 + +ftpPushIncludeTime OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF include the time in the name of the pushed file" + ::= { ftpPush 15 } + --1.3.6.1.4.1.3052.10.2.4.9.15 + +ftpPushIncludeSeq OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF include a sequence number in the name of the pushed file" + ::= { ftpPush 16 } + --1.3.6.1.4.1.3052.10.2.4.9.16 + +ftpPushPermissions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Unix permissions to apply to pushed files (octal notation)." + ::= { ftpPush 17 } + --1.3.6.1.4.1.3052.10.2.4.9.17 + + +pppDialEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF PPP dialout enabled" + ::= { pppDial 1 } + --1.3.6.1.4.1.3052.10.2.4.10.1.1 + +pppDialNumber OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "phone number to dial" + ::= { pppDial 2 } + --1.3.6.1.4.1.3052.10.2.4.10.1.2 + +pppDialIdleTimeout OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Seconds of inactivity after which the unit disconnects" + ::= { pppDial 5 } + --1.3.6.1.4.1.3052.10.2.4.10.1.5 + +pppDialRetries OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Number of dialing retries for PPP" + ::= { pppDial 6 } + --1.3.6.1.4.1.3052.10.2.4.10.1.6 + +pppDialCDTimeout OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Number of seconds to wait after dialing for CD before + giving up" + ::= { pppDial 7 } + --1.3.6.1.4.1.3052.10.2.4.10.1.7 + +pppDialLoginTimeout OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Seconds to wait to negotiate PPP after connecting" + ::= { pppDial 8 } + --1.3.6.1.4.1.3052.10.2.4.10.1.8 + +pppDialMdmInit OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Modem init string to use when dialing PPP" + ::= { pppDial 9 } + --1.3.6.1.4.1.3052.10.2.4.10.1.9 + +pppDialSuggestIP OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "IP address to suggest as the unit's end (local end) of the + PPP link" + ::= { pppDial 10 } + --1.3.6.1.4.1.3052.10.2.4.10.1.10 + +pppDialPlainLogin OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF look for login/password prompt before negotiating + PPP" + ::= { pppDial 11 } + --1.3.6.1.4.1.3052.10.2.4.10.1.11 + +pppHostEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF Unit accepts PPP negotiation" + ::= { pppHost 1 } + --1.3.6.1.4.1.3052.10.2.4.10.2.1 + +pppHostIdleTimeout OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Seconds of inactivity after which PPP-hosted link will + terminate" + ::= { pppHost 2 } + --1.3.6.1.4.1.3052.10.2.4.10.2.2 + +pppHostLocalIP OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Local IP address to negotiate" + ::= { pppHost 3 } + --1.3.6.1.4.1.3052.10.2.4.10.2.3 + +pppHostRemoteIP OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Remote IP address to hand out to PPP peer" + ::= { pppHost 4 } + --1.3.6.1.4.1.3052.10.2.4.10.2.4 + +-- Routing + +pppRoutingEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF unit routes IP traffic from PPP/Wireless to Ethernet" + ::= { routing 1 } + --1.3.6.1.4.1.3052.10.2.4.11.1 + +ethRoutingEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF unit routes IP traffic from Ethernet to PPP/Wireless" + ::= { routing 2 } + --1.3.6.1.4.1.3052.10.2.4.11.2 + +ethRoutingNATEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF unit applies NAT on routed IP frames egressing the + unit on its PPP interface" + ::= { routing 3 } + --1.3.6.1.4.1.3052.10.2.4.11.3 + +routingInterface OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "When Ethernet routing is enabled (routing.1), this is the + Ethernet interface to which IP frames received on PPP are + routed" + ::= { routing 4 } + --1.3.6.1.4.1.3052.10.2.4.11.4 + +eth2WanRoutingEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Make ETH2 operate as a WAN port to route outbound traffic + arriving on ETH1." + ::= { routing 5 } + --1.3.6.1.4.1.3052.10.2.4.11.5 + +-- IP Restrictions + +ipRestrictionTable OBJECT-TYPE + SYNTAX SEQUENCE OF IPRestrictionConfig + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table of IP restrictions" + ::= { ipRestriction 1 } + --1.3.6.1.4.1.3052.10.2.4.12.1.1 + +ipRestrictionEntry OBJECT-TYPE + SYNTAX IPRestrictionConfig + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry for table of IP restrictions" + INDEX { ipRestrictionIndex } + ::= { ipRestrictionTable 1 } + --1.3.6.1.4.1.3052.10.2.4.12.1.1 + +ipRestrictionIndex OBJECT-TYPE + SYNTAX Integer32 (1..8) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Index for table of IP restrictions" + ::= { ipRestrictionEntry 1 } + --1.3.6.1.4.1.3052.10.2.4.12.1.1.1.1 + +ipRestrictionEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF enable this IP restriction" + ::= { ipRestrictionEntry 2 } + --1.3.6.1.4.1.3052.10.2.4.12.1.1.1.2 + +ipRestrictionMask OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "IP restriction mask" + ::= { ipRestrictionEntry 3 } + --1.3.6.1.4.1.3052.10.2.4.12.1.1.1.3 + + +-- RTS + + +rtsFileTable OBJECT-TYPE + SYNTAX SEQUENCE OF RTSFileConfig + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table of RTS files" + ::= { rts 1 } + --1.3.6.1.4.1.3052.10.2.4.13.1 + +rtsFileEntry OBJECT-TYPE + SYNTAX RTSFileConfig + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry for table of RTS files" + INDEX { rtsFileIndex } + ::= { rtsFileTable 1 } + --1.3.6.1.4.1.3052.10.2.4.13.1 + +rtsFileIndex OBJECT-TYPE + SYNTAX Integer32 (1..16) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Index for table of RTS files" + ::= { rtsFileEntry 1 } + --1.3.6.1.4.1.3052.10.2.4.13.1.1.1 + +rtsFileMode OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "RTS mode (OFF,LISTEN,PUSH) for FILEx" + ::= { rtsFileEntry 2 } + --1.3.6.1.4.1.3052.10.2.4.13.1.1.2 + +rtsFileShowAnswer OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Show answer string upon RTS connect for FILEx" + ::= { rtsFileEntry 3 } + --1.3.6.1.4.1.3052.10.2.4.13.1.1.3 + +rtsFileReqXON OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF require XON to start flow for FILEx" + ::= { rtsFileEntry 4 } + --1.3.6.1.4.1.3052.10.2.4.13.1.1.4 + +rtsFileTimeout OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Idle connection close timer (0 means no timeout) for FILEx" + ::= { rtsFileEntry 5 } + --1.3.6.1.4.1.3052.10.2.4.13.1.1.5 + +rtsFileEmptyClose OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF close the socket when FILEx is empty" + ::= { rtsFileEntry 6 } + --1.3.6.1.4.1.3052.10.2.4.13.1.1.6 + +rtsFilePushHost OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Host to which FILEx should be pushed via RTS" + ::= { rtsFileEntry 7 } + --1.3.6.1.4.1.3052.10.2.4.13.1.1.7 + +rtsFilePushPort OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "TCP port to which FILEx should be pushed via RTS" + ::= { rtsFileEntry 8 } + --1.3.6.1.4.1.3052.10.2.4.13.1.1.8 + +rtsFilePushRetryTimer OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Retry timer (seconds) for retrying failed RTS push connect + attempts" + ::= { rtsFileEntry 9 } + --1.3.6.1.4.1.3052.10.2.4.13.1.1.9 + +-- RTS Alarms + +rtsAlarmsMode OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "RTS mode (OFF,LISTEN,PUSH) for alarms file" + ::= { rtsAlarms 1 } + --1.3.6.1.4.1.3052.10.2.4.13.2.1 + +rtsAlarmsShowAnswer OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Show answer string upon RTS connect for alarms file" + ::= { rtsAlarms 2 } + --1.3.6.1.4.1.3052.10.2.4.13.2.2 + +rtsAlarmsReqXON OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF require XON to start flow for alarms file" + ::= { rtsAlarms 3 } + --1.3.6.1.4.1.3052.10.2.4.13.2.3 + +rtsAlarmsTimeout OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Idle connection close timer (0 means no timeout) for alarms + file" + ::= { rtsAlarms 4 } + --1.3.6.1.4.1.3052.10.2.4.13.2.4 + +rtsAlarmsEmptyClose OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF close the socket when this file is empty for alarms + file" + ::= { rtsAlarms 5 } + --1.3.6.1.4.1.3052.10.2.4.13.2.5 + +rtsAlarmsPushHost OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Host to which alarms file should be pushed via RTS" + ::= { rtsAlarms 6 } + --1.3.6.1.4.1.3052.10.2.4.13.2.6 + +rtsAlarmsPushPort OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "TCP port to which alarms file should be pushed via RTS" + ::= { rtsAlarms 7 } + --1.3.6.1.4.1.3052.10.2.4.13.2.7 + +rtsAlarmsPushRetryTimer OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Retry timer (seconds) for retrying failed RTS push connect + attempts" + ::= { rtsAlarms 8 } + --1.3.6.1.4.1.3052.10.2.4.13.2.8 + +-- Traps + +trapIncludeDateTime OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF include date and time in stock trap message" + ::= { trapInclude 1 } + --1.3.6.1.4.1.3052.10.2.4.14.1.1 + +trapIncludeSiteName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF include site name in stock trap message" + ::= { trapInclude 2 } + --1.3.6.1.4.1.3052.10.2.4.14.1.2 + +trapIncludeSensorID OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF include sensor ID in stock trap message" + ::= { trapInclude 3 } + --1.3.6.1.4.1.3052.10.2.4.14.1.3 + +trapIncludeUDName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF include user defined name in stock trap message" + ::= { trapInclude 4 } + --1.3.6.1.4.1.3052.10.2.4.14.1.4 + +trapIncludeUDState OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF include user defined state in stock trap message" + ::= { trapInclude 5 } + --1.3.6.1.4.1.3052.10.2.4.14.1.5 + +trapIncludeSourceAddress OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF include source IP address in stock trap message" + ::= { trapInclude 6 } + --1.3.6.1.4.1.3052.10.2.4.14.1.6 + +trapAuthFailEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF enable trap sent upon SNMP authentication failure" + ::= { trap 2 } + --1.3.6.1.4.1.3052.10.2.4.14.2 + +-- Route testing + +routeTestEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF enable route testing" + ::= { routeTest 1 } + --1.3.6.1.4.1.3052.10.2.4.15.1 + + +routeTestPeriod OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The period which a route is considered valid" + ::= { routeTest 2 } + --1.3.6.1.4.1.3052.10.2.4.15.2 + +routeTestAddressTable OBJECT-TYPE + SYNTAX SEQUENCE OF RouteTestConfig + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table of route testing addresses" + ::= { routeTest 3 } + --1.3.6.1.4.1.3052.10.2.4.15.3 + +routeTestAddressEntry OBJECT-TYPE + SYNTAX RouteTestConfig + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry for table of RTS files" + INDEX { routeTestAddressIndex } + ::= { routeTestAddressTable 1 } + --1.3.6.1.4.1.3052.10.2.4.15.3.1 + +routeTestAddressIndex OBJECT-TYPE + SYNTAX Integer32 (1..3) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Index for table of RTS files" + ::= { routeTestAddressEntry 1 } + --1.3.6.1.4.1.3052.10.2.4.15.3.1.1 + +routeTestAddress OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Address to ping to see if the route to it is valid" + ::= { routeTestAddressEntry 2 } + --1.3.6.1.4.1.3052.10.2.4.15.3.1.2 + + +-- Wireless + + +wirelessMode OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Wireless mode (OFF,PERMANENT-EDGE)" + ::= { wireless 1 } + --1.3.6.1.4.1.3052.10.2.4.16.1 + +wirelessAPN OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Wireless access point name" + ::= { wireless 2 } + --1.3.6.1.4.1.3052.10.2.4.16.2 + +wirelessIdleTimeout OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Wireless idle timeout" + ::= { wireless 3 } + --1.3.6.1.4.1.3052.10.2.4.16.3 + +wirelessDRE OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Default route enable for wireless network interface. + When this is ON, the wireless link, if up, becomes + the default route, overriding the default route setting + (defaultRouter object). When OFF, the default route + setting controls the default route and the wireless link + does not become the default route." + ::= { wireless 9 } + --1.3.6.1.4.1.3052.10.2.4.16.9 + +wirelessPPPUsername OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Username for PPP-based wireless modem connections." + ::= { wireless 10 } + --1.3.6.1.4.1.3052.10.2.4.16.10 + +wirelessFirewall OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable wireless modem firewall." + ::= { wireless 11 } + --1.3.6.1.4.1.3052.10.2.4.16.11 + +wirelessKeepaliveThreshold OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Minutes of no RX activity before sending keep-alive." + ::= { wireless 12 } + --1.3.6.1.4.1.3052.10.2.4.16.12 + +wirelessPPPDebug OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable wireless modem PPP debug." + ::= { wireless 13 } + --1.3.6.1.4.1.3052.10.2.4.16.13 + +wirelessConnEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable wireless modem connectivity check." + ::= { wirelessConnectivity 1 } + --1.3.6.1.4.1.3052.10.2.4.16.20.1 + +wirelessConnCheckInterval OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Wireless connectivity check interval in minutes." + ::= { wirelessConnectivity 2 } + --1.3.6.1.4.1.3052.10.2.4.16.20.2 + +wirelessConnFailThreshold OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Wireless connectivity fail threshold." + ::= { wirelessConnectivity 3 } + --1.3.6.1.4.1.3052.10.2.4.16.20.3 + +wirelessConnIP1 OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Wireless connectivity check IP address 1." + ::= { wirelessConnectivity 10 } + --1.3.6.1.4.1.3052.10.2.4.16.20.10 + +wirelessConnIP2 OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Wireless connectivity check IP address 2." + ::= { wirelessConnectivity 11 } + --1.3.6.1.4.1.3052.10.2.4.16.20.11 + + +-- Email + + +emailServer OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "SMTP server to which the unit sends email" + ::= { email 1 } + --1.3.6.1.4.1.3052.10.2.4.17.1 + +emailDomain OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Domain to use in recipient address" + ::= { email 2 } + --1.3.6.1.4.1.3052.10.2.4.17.2 + +emailAuthEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF enable SMTP authentication" + ::= { email 3 } + --1.3.6.1.4.1.3052.10.2.4.17.3 + +-- Advanced network config + +arpFilter OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ARP filter code" + ::= { netAdvanced 1 } + --1.3.6.1.4.1.3052.10.2.4.18.1 + + +-- Web interface + +webEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF for the web interface" + ::= { web 1 } + --1.3.6.1.4.1.3052.10.2.4.19.1 + +webPort OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "TCP port on which web interface listens" + ::= { web 2 } + --1.3.6.1.4.1.3052.10.2.4.19.2 + +webTimeout OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Web interface session timeout (seconds)" + ::= { web 3 } + --1.3.6.1.4.1.3052.10.2.4.19.3 + + +-- XML Proxy + +wxpEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Globally enables/disables the XML Proxy feature. This feature + is not available in the STD software build." + ::= { webXMLProxy 1 } + --1.3.6.1.4.1.3052.10.2.4.19.4.1 + +wxpDeviceTable OBJECT-TYPE + SYNTAX SEQUENCE OF WebXMLProxyDeviceConfig + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table of XML Proxy devices." + ::= { webXMLProxy 2 } + --1.3.6.1.4.1.3052.10.2.4.19.4.2 + +wxpDeviceEntry OBJECT-TYPE + SYNTAX WebXMLProxyDeviceConfig + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry for table of XML Proxy devices." + INDEX { wxpDeviceIndex } + ::= { wxpDeviceTable 1 } + --1.3.6.1.4.1.3052.10.2.4.19.4.2.1 + +wxpDeviceIndex OBJECT-TYPE + SYNTAX Integer32 (1..16) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Index for table of XML Proxy devices." + ::= { wxpDeviceEntry 1 } + --1.3.6.1.4.1.3052.10.2.4.19.4.2.1.1 + +wxpDeviceEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enables/disables this particular XML device configuration." + ::= { wxpDeviceEntry 2 } + --1.3.6.1.4.1.3052.10.2.4.19.4.2.1.2 + +wxpDeviceIPAddress OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "IP address for device." + ::= { wxpDeviceEntry 3 } + --1.3.6.1.4.1.3052.10.2.4.19.4.2.1.3 + +wxpDevicePort OBJECT-TYPE + SYNTAX Integer32 (0..65535) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "TCP port on which to connect via HTTP to fetch the XML file." + ::= { wxpDeviceEntry 4 } + --1.3.6.1.4.1.3052.10.2.4.19.4.2.1.4 + +wxpDeviceRemoteFile OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Path and name of the XML file on the remote device. E.g., + 'xml/telemetry.xml' if the URL for the XML is + 'http://<remote device address>/xml/telemetry.xml'." + ::= { wxpDeviceEntry 5 } + --1.3.6.1.4.1.3052.10.2.4.19.4.2.1.5 + +wxpDeviceLocalFile OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Name of file in which the remote file content will be cached + on the unit. E.g., 'alpha-telemetry.xml' if the URL for the + unit-cached XML is intended to be + 'http://<unit address>/xmlproxy/alpha-telemetry.xml'." + ::= { wxpDeviceEntry 6 } + --1.3.6.1.4.1.3052.10.2.4.19.4.2.1.6 + +wxpDeviceTimeout OBJECT-TYPE + SYNTAX Integer32 (1..255) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "How long in seconds to wait for the device to serve the + remote file before cancelling the fetch operation." + ::= { wxpDeviceEntry 7 } + --1.3.6.1.4.1.3052.10.2.4.19.4.2.1.7 + +wxpDeviceTimestamp OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Timestamp of last successful XML file fetch/cache operation. + If blank then either the device is not configured or there + was a fetch error. If not blank, but not updating, then this + indicates that the fetch succeeded at one point but then + encountered an error." + ::= { wxpDeviceEntry 8 } + --1.3.6.1.4.1.3052.10.2.4.19.4.2.1.8 + + +-- Ethernet Expansion + +ethExpanIp OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "IPv4 address of the unit reachable by nodes on the network interface + consisting of the Ethernet Expansion Card(s). If this is default + (0.0.0.0), then each card will still convey Ethernet traffic + (acting as Ethernet switch) among its nodes but those nodes will not + be able to communicate with the unit." + ::= { ethExpan 1 } + --1.3.6.1.4.1.3052.10.2.4.20.1 + +ethExpanMask OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "IPv4 subnet mask for the Ethernet Expansion network interface." + ::= { ethExpan 2 } + --1.3.6.1.4.1.3052.10.2.4.20.2 + +ethExpanCardTable OBJECT-TYPE + SYNTAX SEQUENCE OF EthernetExpansionCardConfig + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table of Ethernet Expansion cards" + ::= { ethExpan 3 } + --1.3.6.1.4.1.3052.10.2.4.20.3 + +ethExpanCardEntry OBJECT-TYPE + SYNTAX EthernetExpansionCardConfig + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry for table of Ethernet Expansion cards" + INDEX { ethExpanCardIndex } + ::= { ethExpanCardTable 1 } + --1.3.6.1.4.1.3052.10.2.4.20.3.1 + +ethExpanCardIndex OBJECT-TYPE + SYNTAX Integer32 (1..2) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Index for table of Ethernet Expansion cards" + ::= { ethExpanCardEntry 1 } + --1.3.6.1.4.1.3052.10.2.4.20.3.1.1 + +ethExpanCardMAC OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "MAC address for each Ethernet Expansion Card that is bridged + together to form the Ethernet Expansion network interface." + ::= { ethExpanCardEntry 2 } + --1.3.6.1.4.1.3052.10.2.4.20.3.1.2 + +ethExpanDHCPStartIp OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Starting IP address for serving DHCP addresses on the Ethernet + Expansion network interface. If this is default (0.0.0.0) then + the unit will not run DHCP to serve addresses." + ::= { ethExpanDHCP 1 } + --1.3.6.1.4.1.3052.10.2.4.20.6.1 + +ethExpanDHCPLeaseTime OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Lease time for Ethernet Expansion DHCP clients in minutes." + ::= { ethExpanDHCP 2 } + --1.3.6.1.4.1.3052.10.2.4.20.6.2 + + + +-- IPv6 + +ipv6DefaultRouter OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IPv6 default router in use." + ::= { ipv6 1 } + --1.3.6.1.4.1.3052.10.2.4.21.1 + + + +-- CPE table + +cpeTable OBJECT-TYPE + SYNTAX SEQUENCE OF CPEConfig + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table of CPEs" + ::= { cpe 1 } + --1.3.6.1.4.1.3052.10.2.4.22.1 + +cpeEntry OBJECT-TYPE + SYNTAX CPEConfig + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry for table of CPEs" + INDEX { cpeIndex } + ::= { cpeTable 1 } + --1.3.6.1.4.1.3052.10.2.4.22.1.1 + +cpeIndex OBJECT-TYPE + SYNTAX Integer32 (1..16) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Index for table of CPEs" + ::= { cpeEntry 1 } + --1.3.6.1.4.1.3052.10.2.4.22.1.1.1 + +cpeHost OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "CPE host (IP address or DNS name)" + ::= { cpeEntry 2 } + --1.3.6.1.4.1.3052.10.2.4.22.1.1.2 + +cpeName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "CPE name, informational only" + ::= { cpeEntry 3 } + --1.3.6.1.4.1.3052.10.2.4.22.1.1.3 + +cpeDescription OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "CPE description, informational only" + ::= { cpeEntry 4 } + --1.3.6.1.4.1.3052.10.2.4.22.1.1.4 + +cpeKeepalive OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Number of seconds between each successful ping request." + ::= { cpeEntry 5 } + --1.3.6.1.4.1.3052.10.2.4.22.1.1.5 + +cpeThreshold OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Number of unsuccessful pings that triggers the CPE event." + ::= { cpeEntry 6 } + --1.3.6.1.4.1.3052.10.2.4.22.1.1.6 + +cpeEventReminderInterval OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "CPE event reminder interval (minutes)." + ::= { cpeEntry 7 } + --1.3.6.1.4.1.3052.10.2.4.22.1.1.7 + +cpeKeepaliveTicks OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "CPE ping period in 16ths of a second (nonzero overrides keepalive)." + ::= { cpeEntry 20 } + --1.3.6.1.4.1.3052.10.2.4.22.1.1.20 + +cpePingSize OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Number of bytes in CPE ping payload" + ::= { cpeEntry 21 } + --1.3.6.1.4.1.3052.10.2.4.22.1.11 + +cpeInfoReset OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Set any number to reset CPE ping stats." + ::= { cpeEntry 30 } + --1.3.6.1.4.1.3052.10.2.4.22.1.1.30 + +cpeInfoNumReq OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Total number of requests transmitted." + ::= { cpeEntry 31 } + --1.3.6.1.4.1.3052.10.2.4.22.1.1.31 + +cpeInfoNumGoodResp OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Total number of non-corrupt responses." + ::= { cpeEntry 32 } + --1.3.6.1.4.1.3052.10.2.4.22.1.1.32 + +cpeInfoNumBadResp OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Total number of corrupt responses." + ::= { cpeEntry 33 } + --1.3.6.1.4.1.3052.10.2.4.22.1.1.33 + +cpeInfoNumLostResp OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Total number of requests with no response." + ::= { cpeEntry 34 } + --1.3.6.1.4.1.3052.10.2.4.22.1.1.34 + +cpeInfoPercentLoss OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Percent loss (missing responses / total requests)." + ::= { cpeEntry 35 } + --1.3.6.1.4.1.3052.10.2.4.22.1.1.35 + +cpeInfoPercentBad OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Percent corrupt (corrupt responses / total requests)." + ::= { cpeEntry 36 } + --1.3.6.1.4.1.3052.10.2.4.22.1.1.36 + + +-- DNP3 + +dnp3Mode OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "DNP3 operating mode." + ::= { dnp3General 1 } + --1.3.6.1.4.1.3052.10.2.4.23.1.1 + +dnp3SelfAddressEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "DNP3 self-address enabled." + ::= { dnp3General 2 } + --1.3.6.1.4.1.3052.10.2.4.23.1.2 + +dnp3KeepaliveTimeout OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Keepalive timeout in seconds." + ::= { dnp3General 3 } + --1.3.6.1.4.1.3052.10.2.4.23.1.3 + +dnp3MaxRXFragmentSize OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Maximum size of a received fragment in bytes." + ::= { dnp3General 4 } + --1.3.6.1.4.1.3052.10.2.4.23.1.4 + +dnp3MaxTXFragmentSize OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Maximum size of a transmitted fragment in bytes." + ::= { dnp3General 5 } + --1.3.6.1.4.1.3052.10.2.4.23.1.5 + +dnp3UnsolResponseEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable unsolicited responses." + ::= { dnp3General 6 } + --1.3.6.1.4.1.3052.10.2.4.23.1.6 + +dnp3UnsolResponseTimeout OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Unsolicited response confirmation timeout in seconds." + ::= { dnp3General 7 } + --1.3.6.1.4.1.3052.10.2.4.23.1.7 + +dnp3UnsolResponseRetries OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Unsolicited response confirmation timeout retries." + ::= { dnp3General 8 } + --1.3.6.1.4.1.3052.10.2.4.23.1.8 + +dnp3LogFilter OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Numeric code to describe what gets logged (for support/troubleshooting analysis only)." + ::= { dnp3General 9 } + --1.3.6.1.4.1.3052.10.2.4.23.1.9 + +dnp3OutstationTCPPort OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "TCP port on which to listen for connections." + ::= { dnp3Outstation 1 } + --1.3.6.1.4.1.3052.10.2.4.23.2.1 + +dnp3OutstationDNP3Address OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "DNP3 address of the outstation. " + ::= { dnp3Outstation 2 } + --1.3.6.1.4.1.3052.10.2.4.23.2.2 + +dnp3OutstationMasterIPAddress OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "IP (v4 or v6) address (non-resolved) of the intended master. Default blank. + If non-blank then the outstation drops connections from TCP clients not at this address." + ::= { dnp3Outstation 3 } + --1.3.6.1.4.1.3052.10.2.4.23.2.3 + +dnp3OutstationMasterDNP3Address OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "DNP3 address of the intended master upon connection. Range 0 - 65520, default 65520. + If set to 0 - 65519 then the outstation discards DNP3 data link frames not from this + address. 65520 is not a valid DNP3 address; if set to 65520 then it means the + outstation accepts frames from any address." + ::= { dnp3Outstation 4 } + --1.3.6.1.4.1.3052.10.2.4.23.2.4 + +dnp3OutstationUnsolResponseDNP3Address OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "DNP3 destination address of unsolicited responses. Range 0 - 65520, default 65520. + If set to 65520 then it means the outstation addresses data link frames of + unsolicited responses to the source address of the last accepted frame received + from the master." + ::= { dnp3Outstation 5 } + --1.3.6.1.4.1.3052.10.2.4.23.2.5 + + + +dnp3DuplicateFragmentCount OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Count of duplicate fragments received." + ::= { dnp3Error 1 } + --1.3.6.1.4.1.3052.10.2.4.23.4.1 + +dnp3CollidingFragmentCount OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Count of colliding fragments received." + ::= { dnp3Error 2 } + --1.3.6.1.4.1.3052.10.2.4.23.4.2 + +dnp3UnsolResponseCfmFailCount OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Count of unsolicited response confirmation failures." + ::= { dnp3Error 3 } + --1.3.6.1.4.1.3052.10.2.4.23.4.3 + +dnp3SolCfmFailCount OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Count of solicited response confirmation failures." + ::= { dnp3Error 4 } + --1.3.6.1.4.1.3052.10.2.4.23.4.4 + +dnp3ObjParseErrorCount OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Count of received data object parse errors." + ::= { dnp3Error 5 } + --1.3.6.1.4.1.3052.10.2.4.23.4.5 + +dnp3FrameParseErrorCount OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Count of received frame parse errors." + ::= { dnp3Error 6 } + --1.3.6.1.4.1.3052.10.2.4.23.4.6 + +dnp3DiscardedFrameCount OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Count of received frames discarded." + ::= { dnp3Error 7 } + --1.3.6.1.4.1.3052.10.2.4.23.4.7 + +dnp3BadBlockCount OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Count of received frame blocks with bad CRC." + ::= { dnp3Error 8 } + --1.3.6.1.4.1.3052.10.2.4.23.4.8 + +dnp3UnsolResponseRetryCount OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Count of retried unsolicited responses." + ::= { dnp3Error 9 } + --1.3.6.1.4.1.3052.10.2.4.23.4.9 + +dnp3UnsupportedFrameCount OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Count of received frames accepted (good CRC and addressed to + the outstation) with an unsupported data link function code." + ::= { dnp3Error 10 } + --1.3.6.1.4.1.3052.10.2.4.23.4.10 + + +dnp3OutstationCount OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Count of running outstation instances." + ::= { dnp3Status 1 } + --1.3.6.1.4.1.3052.10.2.4.23.5.1 + +dnp3ConnPeer OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Description of the connected peer (the TCP socket endpoint of the master)." + ::= { dnp3Status 2 } + --1.3.6.1.4.1.3052.10.2.4.23.5.2 + +dnp3StartTime OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "When the outstation instance started." + ::= { dnp3Status 3 } + --1.3.6.1.4.1.3052.10.2.4.23.5.3 + +dnp3EventAwaitingSolCfmCount OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of events reported and awaiting solicited confirmation; usually 0." + ::= { dnp3Status 4 } + --1.3.6.1.4.1.3052.10.2.4.23.5.4 + +dnp3EventAwaitingUnsolCfmCount OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of events reported and awaiting unsolicited confirmation; usually 0." + ::= { dnp3Status 5 } + --1.3.6.1.4.1.3052.10.2.4.23.5.5 + +dnp3EventCount OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of total events buffered (that is, existing, maybe reported, but not confirmed)." + ::= { dnp3Status 6 } + --1.3.6.1.4.1.3052.10.2.4.23.5.6 + +dnp3EventClass1Count OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Portion of the total events buffered that are class 1 events." + ::= { dnp3Status 7 } + --1.3.6.1.4.1.3052.10.2.4.23.5.7 + +dnp3EventClass2Count OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Portion of the total events buffered that are class 2 events." + ::= { dnp3Status 8 } + --1.3.6.1.4.1.3052.10.2.4.23.5.8 + +dnp3EventClass3Count OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Portion of the total events buffered that are class 3 events." + ::= { dnp3Status 9 } + --1.3.6.1.4.1.3052.10.2.4.23.5.9 + +dnp3RxFragmentTime OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Time of the last fragment received." + ::= { dnp3Status 10 } + --1.3.6.1.4.1.3052.10.2.4.23.5.10 + +dnp3TxFragmentTime OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Time of the last fragment transmitted." + ::= { dnp3Status 11 } + --1.3.6.1.4.1.3052.10.2.4.23.5.11 + +dnp3TxCachedResponseCount OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Count of cached responses transmitted." + ::= { dnp3Status 12 } + --1.3.6.1.4.1.3052.10.2.4.23.5.12 + +dnp3TxUnsolResponseCount OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Count of unsolicited responses transmitted." + ::= { dnp3Status 13 } + --1.3.6.1.4.1.3052.10.2.4.23.5.13 + +dnp3TxSolResponseCount OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Count of solicited responses transmitted." + ::= { dnp3Status 14 } + --1.3.6.1.4.1.3052.10.2.4.23.5.14 + +dnp3TxFragmentReqCfmCount OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Count of fragments transmitted that required confirmation." + ::= { dnp3Status 15 } + --1.3.6.1.4.1.3052.10.2.4.23.5.15 + +dnp3RxUnsolResponseCfmCount OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Count of unsolicited response confirmations received." + ::= { dnp3Status 16 } + --1.3.6.1.4.1.3052.10.2.4.23.5.16 + +dnp3RxSolResponseCfmCount OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Count of solicited response confirmations received." + ::= { dnp3Status 17 } + --1.3.6.1.4.1.3052.10.2.4.23.5.17 + +dnp3RxFunctionCount OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Count of total application function codes received." + ::= { dnp3Status 18 } + --1.3.6.1.4.1.3052.10.2.4.23.5.18 + +dnp3RxReadFunctionCount OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Count of read application function codes received." + ::= { dnp3Status 19 } + --1.3.6.1.4.1.3052.10.2.4.23.5.19 + +dnp3RxWriteFunctionCount OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Count of write application function codes received." + ::= { dnp3Status 20 } + --1.3.6.1.4.1.3052.10.2.4.23.5.20 + +dnp3RxDirOpFunctionCount OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Count of direct operate application function codes received." + ::= { dnp3Status 21 } + --1.3.6.1.4.1.3052.10.2.4.23.5.21 + +dnp3RxEnableURCount OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Count of enable unsolicited application function codes received." + ::= { dnp3Status 22 } + --1.3.6.1.4.1.3052.10.2.4.23.5.22 + +dnp3RxDisableURCount OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Count of disabled unsolicited application function codes received." + ::= { dnp3Status 23 } + --1.3.6.1.4.1.3052.10.2.4.23.5.23 + +dnp3RxSolObjectCount OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Count of data objects received in solicited requests." + ::= { dnp3Status 40 } + --1.3.6.1.4.1.3052.10.2.4.23.5.40 + +dnp3TxSolObjectCount OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Count of data objects transmitted in solicted responses." + ::= { dnp3Status 41 } + --1.3.6.1.4.1.3052.10.2.4.23.5.41 + +dnp3RxFrameTime OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Time of the last frame received." + ::= { dnp3Status 42 } + --1.3.6.1.4.1.3052.10.2.4.23.5.42 + +dnp3TxFrameTime OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Time of the last frame transmitted." + ::= { dnp3Status 43 } + --1.3.6.1.4.1.3052.10.2.4.23.5.43 + +dnp3TxFrameCount OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Count of total frames transmitted." + ::= { dnp3Status 44 } + --1.3.6.1.4.1.3052.10.2.4.23.5.44 + +dnp3RxAcceptedFrameCount OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Count of total frames accepted." + ::= { dnp3Status 45 } + --1.3.6.1.4.1.3052.10.2.4.23.5.45 + +dnp3RxSupportedFrameCount OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Count of total frames accepted with a supported data link function code." + ::= { dnp3Status 46 } + --1.3.6.1.4.1.3052.10.2.4.23.5.46 + + +--*************************************************************************************** +--Modem Section 2.5 +--*************************************************************************************** + + + + + +modemFormat OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Modem data format (8N1,7E1,7O1,7N1)" + ::= { modem 1 } + --1.3.6.1.4.1.3052.10.2.5.1 + +modemInitString OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Init string for modem" + ::= { modem 2 } + --1.3.6.1.4.1.3052.10.2.5.2 + + +modemCallAttempts OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Max mumber of times the modem should try to call out until + successful connect" + ::= { modem 4 } + --1.3.6.1.4.1.3052.10.2.5.4 + +modemCallDelay OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Minimum delay (seconds) between callouts" + ::= { modem 5 } + --1.3.6.1.4.1.3052.10.2.5.6 + + +modemCmdTimout OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Number of minutes after which an idle command session via + modem is terminated" + ::= { modem 6 } + --1.3.6.1.4.1.3052.10.2.5.6 + +modemGoto OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "When a user connects, where that user is routed (command + session, passthrough to port 1, passthrough to port 2, etc.)" + ::= { modem 7 } + --1.3.6.1.4.1.3052.10.2.5.7 + + +modemCLIDEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF Calling Line Identification security" + ::= { modemClid 1 } + --1.3.6.1.4.1.3052.10.2.5.8.1 + + +modemCLIDNumberTable OBJECT-TYPE + SYNTAX SEQUENCE OF ModemCLIDNumberConfig + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table of authorized callers identified by phone number" + ::= { modemClid 2 } + --1.3.6.1.4.1.3052.10.2.5.8.2 + +modemCLIDNumberEntry OBJECT-TYPE + SYNTAX ModemCLIDNumberConfig + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry for table of CLID numbers" + INDEX { modemCLIDNumberIndex } + ::= { modemCLIDNumberTable 1 } + --1.3.6.1.4.1.3052.10.2.5.8.2.1 + +modemCLIDNumberIndex OBJECT-TYPE + SYNTAX Integer32 (1..20) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Index for table of CLID numbers" + ::= { modemCLIDNumberEntry 1 } + --1.3.6.1.4.1.3052.10.2.5.8.2.1.1 + +modemCLIDNumber OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "auhorized CLID number" + ::= { modemCLIDNumberEntry 2 } + --1.3.6.1.4.1.3052.10.2.5.8.2.1.2 + +modemTAPInitString OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Init string to use for TAP (pager) connections" + ::= { modem 9 } + --1.3.6.1.4.1.3052.10.2.5.9 + +modemTAP8N1 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF: use 8N1 data/parity/stop for TAP connections" + ::= { modem 10 } + --1.3.6.1.4.1.3052.10.2.5.10 + + +--*************************************************************************************** +--Time Section 2.8 +--*************************************************************************************** + +clock OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Text string for date and time; + e.g. 'SUN 01/02/98 12:34:27'. When setting + this object, only the date and time are + required; the unit will ignore a specified + day of week because it is calculated from + the date and time. When this object is included + in a notification as a varbind, it represents + the time that the triggering event occurred." + ::= { time 1 } + --1.3.6.1.4.1.3052.10.2.8.1 + +--*************************************************************************************** +--Console Section 2.10 +--*************************************************************************************** + + +consoleDuplex OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF characters echoed on telnet command session" + ::= { console 1 } + --1.3.6.1.4.1.3052.10.2.10.1 + +consoleTimeout OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Minutes of inactivity after which telnet command session is terminated" + ::= { console 2 } + --1.3.6.1.4.1.3052.10.2.10.2 + +consoleConfirm OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF Prompt to confirm certain actions" + ::= { console 7 } + --1.3.6.1.4.1.3052.10.2.10.7 + +--*************************************************************************************** +--Core Security Section 2.11.1 +--*************************************************************************************** + +scShowPasswordPrompt OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF show password prompt upon login" + ::= { secCore 1 } + --1.3.6.1.4.1.3052.10.2.11.1.1 + +scConsoleLoginRequired OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF login required upon connecting via console" + ::= { secCore 2 } + --1.3.6.1.4.1.3052.10.2.11.1.2 + +scModemLoginRequired OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF login required upon connecting via modem" + ::= { secCore 3 } + --1.3.6.1.4.1.3052.10.2.11.1.3 + +scTelnetLoginRequired OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF login required upon connecting via Telnet" + ::= { secCore 4 } + --1.3.6.1.4.1.3052.10.2.11.1.4 + +scTelnetPTLoginRequired OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF login required upon connecting via Telnet to pass- + through ports (TCP ports 210x)" + ::= { secCore 5 } + --1.3.6.1.4.1.3052.10.2.11.1.5 + +scRTSLoginRequired OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF login required upon connecting to RTS (TCP ports 220x)" + ::= { secCore 6 } + --1.3.6.1.4.1.3052.10.2.11.1.6 + +scAuthMode OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Authentication mode (USERNAME/PW,PW/USERNAME,PASSWORD ONLY)" + ::= { secCore 7 } + --1.3.6.1.4.1.3052.10.2.11.1.7 + +scRightsGroup OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The set of aliases used for the 8 available rights levels" + ::= { secCore 8 } + --1.3.6.1.4.1.3052.10.2.11.1.8 + + +--*************************************************************************************** +--User Security Section 2.11.2 +--*************************************************************************************** + + +secUserTable OBJECT-TYPE + SYNTAX SEQUENCE OF SecUserConfig + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table of users" + ::= { unitSecurity 2 } + --1.3.6.1.4.1.3052.10.2.11.2 + +secUserEntry OBJECT-TYPE + SYNTAX SecUserConfig + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry for table of users" + INDEX { secUserIndex } + ::= { secUserTable 1 } + --1.3.6.1.4.1.3052.10.2.11.2.1 + +secUserIndex OBJECT-TYPE + SYNTAX Integer32 (1..12) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Index for table of users" + ::= { secUserEntry 1 } + --1.3.6.1.4.1.3052.10.2.11.2.1.1 + +secUserEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF enable user" + ::= { secUserEntry 2 } + --1.3.6.1.4.1.3052.10.2.11.2.1.2 + +secUserConnectVia OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Methods by which user is allowed to connect: + L=local (console) + T=Telnet + M=modem + F=FTP + R=RTS + S=SSH + " + ::= { secUserEntry 5 } + --1.3.6.1.4.1.3052.10.2.11.2.1.5 + +secUserLoginTo OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The function presented to the user upon login (COMMAND, + PASSTHROUGH,MENU)" + ::= { secUserEntry 6 } + --1.3.6.1.4.1.3052.10.2.11.2.1.6 + +secUserAccessFile OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The default access file associated with the user" + ::= { secUserEntry 7 } + --1.3.6.1.4.1.3052.10.2.11.2.1.7 + +secUserPTEscapeTo OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The function presented to the user upon escaping pass- + through: currently only MENU" + ::= { secUserEntry 9 } + --1.3.6.1.4.1.3052.10.2.11.2.1.9 + +secUserPPPType OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The kind of PPP access allowed to this user cannot connect + via PPP (NONE), can connect but only to the unit (LOCAL), or + can connect and route to Ethernet (ROUTING)" + ::= { secUserEntry 10 } + --1.3.6.1.4.1.3052.10.2.11.2.1.10 + +secUserRights OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The rights level granted to this user" + ::= { secUserEntry 11 } + --1.3.6.1.4.1.3052.10.2.11.2.1.11 + +secUserEventsReadAccess OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "DENY/ALLOW user to read the events/alarms file" + ::= { secUserEntry 13 } + --1.3.6.1.4.1.3052.10.2.11.2.1.13 + +secUserAuditReadAccess OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "DENY/ALLOW user to read the audit log" + ::= { secUserEntry 14 } + --1.3.6.1.4.1.3052.10.2.11.2.1.14 + +secUserEventsWriteAccess OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "DENY/ALLOW user to delete the events file" + ::= { secUserEntry 16 } + --1.3.6.1.4.1.3052.10.2.11.2.1.16 + +secUserAuditWriteAccess OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "DENY/ALLOW user to write to the audit log" + ::= { secUserEntry 17 } + --1.3.6.1.4.1.3052.10.2.11.2.1.17 + +secUserExpiration OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Expiration date/time of this user" + ::= { secUserEntry 18 } + --1.3.6.1.4.1.3052.10.2.11.2.1.18 + +secUserCallbackNumber1 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Number slot 1 the unit calls for dialback" + ::= { secUserEntry 19 } + --1.3.6.1.4.1.3052.10.2.11.2.1.19 + +secUserCallbackNumber2 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Number slot 2 the unit calls for dialback" + ::= { secUserEntry 20 } + --1.3.6.1.4.1.3052.10.2.11.2.1.20 + +secUserCallbackNumber3 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Number slot 3 the unit calls for dialback" + ::= { secUserEntry 21 } + --1.3.6.1.4.1.3052.10.2.11.2.1.21 + +secUserChallengeTelnetMode OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Telnet challenge mode: when user logs in via telnet, unit + allows access (OFF), presents a challenge (CHALLENGE), or + unit sends a one-time-password (SEND PASSWORD) to a + destination configured by secUserChallengeTelnetSendTo" + ::= { secUserEntry 22 } + --1.3.6.1.4.1.3052.10.2.11.2.1.22 + +secUserChallengeModemMode OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Modem challenge mode: when user logs in via modem, unit + allows access (OFF), presents a challenge (CHALLENGE), sends + a one-time-password (SEND PASSWORD) to a destination + configured by secUserChallengeTelnetSendTo, or dials a + number (CALLBACK) configured with secUserCallbackNumberx" + ::= { secUserEntry 23 } + --1.3.6.1.4.1.3052.10.2.11.2.1.23 + +secUserChallengeConsoleMode OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Console challenge mode: when user logs in via console, unit + allows access (OFF), or presents a challenge (CHALLENGE)" + ::= { secUserEntry 24 } + --1.3.6.1.4.1.3052.10.2.11.2.1.24 + +secUserChallengeTelnetSendTo OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Email action used as the destination address for one-time- + password when a user logs in with a challenge mode of + SEND PASSWORD" + ::= { secUserEntry 25 } + --1.3.6.1.4.1.3052.10.2.11.2.1.25 + +secUserChallengeModemSendTo OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Modem action used as the destination phone number for one- + time-password when a user logs in with a challenge mode of + SEND PASSWORD" + ::= { secUserEntry 26 } + --1.3.6.1.4.1.3052.10.2.11.2.1.26 + +secUserChallengeExpiration OBJECT-TYPE + SYNTAX Integer32 (0..180) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Time (in minutes) after which a one-time-password is sent + that it can be used to log in" + ::= { secUserEntry 27 } + --1.3.6.1.4.1.3052.10.2.11.2.1.27 + + +--*************************************************************************************** +--Factory Security Section 2.11.3 +--*************************************************************************************** + +sfEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF enable factory access" + ::= { secFactory 1 } + --1.3.6.1.4.1.3052.10.2.11.3.1 + +sfSecret OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Secret used for factory access" + ::= { secFactory 2 } + --1.3.6.1.4.1.3052.10.2.11.3.2 + + +--*************************************************************************************** +--SSH Security Section 2.11.3 +--*************************************************************************************** + +--*************************************************************************************** +--Event Section 2.12 +--*************************************************************************************** + +--*************************************************************************************** +--Event Core Section 2.12.1 +--*************************************************************************************** + + +evClassNameTable OBJECT-TYPE + SYNTAX SEQUENCE OF EventClassConfig + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table of classes" + ::= { evCore 1 } + --1.3.6.1.4.1.3052.10.2.12.1.1 + +evClassNameEntry OBJECT-TYPE + SYNTAX EventClassConfig + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry for table of classes" + INDEX { evClassNameIndex } + ::= { evClassNameTable 1 } + --1.3.6.1.4.1.3052.10.2.12.1.1.1 + +evClassNameIndex OBJECT-TYPE + SYNTAX Integer32 (1..12) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Index for table of classes" + ::= { evClassNameEntry 1 } + --1.3.6.1.4.1.3052.10.2.12.1.1.1.1 + +evClassName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Class name for this slot" + ::= { evClassNameEntry 2 } + --1.3.6.1.4.1.3052.10.2.12.1.1.1.2 + +evReminderInterval OBJECT-TYPE + SYNTAX Integer32 (0..65535) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Interval (minutes) between EventSensor reminder events" + ::= { evCore 2 } + --1.3.6.1.4.1.3052.10.2.12.1.2 + +evLogEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF enable event log" + ::= { evLog 1 } + --1.3.6.1.4.1.3052.10.2.12.1.3.1 + +evLogStoreAlarm OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF store data alarms in event log" + ::= { evLog 2 } + --1.3.6.1.4.1.3052.10.2.12.1.3.2 + +evLogMaxSize OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "max size (in KB) of event log" + ::= { evLog 3 } + --1.3.6.1.4.1.3052.10.2.12.1.3.3 + +evLogStoreSensor OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF store EventSensor events in event log" + ::= { evLog 4 } + --1.3.6.1.4.1.3052.10.2.12.1.3.4 + +evLogTimeStampAlarms OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF put timestamps on event log entries" + ::= { evLog 5 } + --1.3.6.1.4.1.3052.10.2.12.1.3.5 + +evLogPrependName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF prepend data event name to data alarm records in event + log" + ::= { evLog 6 } + --1.3.6.1.4.1.3052.10.2.12.1.3.6 + + +evMgmtReprocess OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Number of sensors that have generated events since reset. + Write this to reprocess each sensor's last generated event + since reset. The value to write determines what kind of + events should be reprocessed: + 'all': all sensor events + 'cc': cc events + 'temperature': temperature events + 'humidity': humidity events + 'analog': analog input events" + ::= { evMgmt 3 } + --1.3.6.1.4.1.3052.10.2.12.1.4.3 + + + +--*************************************************************************************** +--Data event section 2.12.2 +--*************************************************************************************** + +evdExitOnTrue OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF: Data alarm evaluator stops checking record against + alarm equations when it finds an equation that matches" + ::= { evdCore 1 } + --1.3.6.1.4.1.3052.10.2.12.2.1.1.1 + +evdFilterAction OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "What happens to a record that matches an equation: + REJECT/ACCEPT" + ::= { evdCore 2 } + --1.3.6.1.4.1.3052.10.2.12.2.1.1.2 + +evdWildCardChar OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Character (in decimal ASCII code format) used to indicate + wildcards in data alarm equation" + ::= { evdCore 3 } + --1.3.6.1.4.1.3052.10.2.12.2.1.1.3 + + +evdTable OBJECT-TYPE + SYNTAX SEQUENCE OF DataEventConfig + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table of data events" + ::= { evData 2 } + --1.3.6.1.4.1.3052.10.2.12.2.2 + +evdEntry OBJECT-TYPE + SYNTAX DataEventConfig + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry for table of data events" + INDEX { evdIndex } + ::= { evdTable 1 } + --1.3.6.1.4.1.3052.10.2.12.2.2.1 + +evdIndex OBJECT-TYPE + SYNTAX Integer32 (1..1000) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Index for table of data events" + ::= { evdEntry 1 } + --1.3.6.1.4.1.3052.10.2.12.2.2.1.1 + +evdEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF enable this data event" + ::= { evdEntry 2 } + --1.3.6.1.4.1.3052.10.2.12.2.2.1.2 + +evdName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Name for this data event" + ::= { evdEntry 3 } + --1.3.6.1.4.1.3052.10.2.12.2.2.1.3 + +evdEquation OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Equation for this data event" + ::= { evdEntry 4 } + --1.3.6.1.4.1.3052.10.2.12.2.2.1.4 + +evdThreshold OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Number of equation matches that must happen to trigger this + data event" + ::= { evdEntry 5 } + --1.3.6.1.4.1.3052.10.2.12.2.2.1.5 + +evdAutoClear OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF this data alarm is automatically cleared (re-armed) + upon reaching the threshold number of matches" + ::= { evdEntry 6 } + --1.3.6.1.4.1.3052.10.2.12.2.2.1.6 + +evdClearInterval OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Interval at which this alarm is automatically cleared (no + bearing with evdAutoClear)" + ::= { evdEntry 7 } + --1.3.6.1.4.1.3052.10.2.12.2.2.1.7 + +evdClearTime OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Tie of day (HH:MM) at which this data alarm is cleared (no + bearing with evdAutoClear)" + ::= { evdEntry 8 } + --1.3.6.1.4.1.3052.10.2.12.2.2.1.8 + +evdActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Actions for this data event" + ::= { evdEntry 9 } + --1.3.6.1.4.1.3052.10.2.12.2.2.1.9 + +evdClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Class for this data event" + ::= { evdEntry 10 } + --1.3.6.1.4.1.3052.10.2.12.2.2.1.10 + +evdTrapNum OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Trap number for this event" + ::= { evdEntry 11 } + --1.3.6.1.4.1.3052.10.2.12.2.2.1.11 + +evdMode OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ALARM/FILTER: what is happens when this data event + triggers: either generate actions (mode=ALARM) )or + ACCEPT/REJECT (via evdFilterAction) the record + (mode=FILTER)" + ::= { evdEntry 12 } + --1.3.6.1.4.1.3052.10.2.12.2.2.1.12 + +evdFieldTable OBJECT-TYPE + SYNTAX SEQUENCE OF DataEventFieldConfig + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table of data event fields" + ::= { evData 3 } + --1.3.6.1.4.1.3052.10.2.12.2.3 + +evdFieldEntry OBJECT-TYPE + SYNTAX DataEventFieldConfig + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry for table of data event fields" + INDEX { evdFieldIndex } + ::= { evdFieldTable 1 } + --1.3.6.1.4.1.3052.10.2.12.2.3.1 + +evdFieldIndex OBJECT-TYPE + SYNTAX Integer32 (1..16) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Index for table of data event fields" + ::= { evdFieldEntry 1 } + --1.3.6.1.4.1.3052.10.2.12.2.3.1.1 + +evdFieldStart OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Start position (1-based) for this data event field" + ::= { evdFieldEntry 2 } + --1.3.6.1.4.1.3052.10.2.12.2.3.1.2 + +evdFieldLength OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Number of characters this data event field occupies" + ::= { evdFieldEntry 3 } + --1.3.6.1.4.1.3052.10.2.12.2.3.1.3 + +evdFieldName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Start position (1-based) for this data event field" + ::= { evdFieldEntry 4 } + --1.3.6.1.4.1.3052.10.2.12.2.3.1.4 + +evdFieldLine OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Line number (1-based, for multiline records) for this data + event field" + ::= { evdFieldEntry 5 } + --1.3.6.1.4.1.3052.10.2.12.2.3.1.5 + +evdFieldType OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Alpha/Numeric type for this data event field" + ::= { evdFieldEntry 6 } + --1.3.6.1.4.1.3052.10.2.12.2.3.1.6 + +evdMacroTable OBJECT-TYPE + SYNTAX SEQUENCE OF DataEventMacroConfig + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table of data event macros" + ::= { evData 4 } + --1.3.6.1.4.1.3052.10.2.12.2.4 + +evdMacroEntry OBJECT-TYPE + SYNTAX DataEventMacroConfig + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry for table of data event macros" + INDEX { evdMacroIndex } + ::= { evdMacroTable 1 } + --1.3.6.1.4.1.3052.10.2.12.2.4.1 + +evdMacroIndex OBJECT-TYPE + SYNTAX Integer32 (1..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Index for table of data event macros" + ::= { evdMacroEntry 1 } + --1.3.6.1.4.1.3052.10.2.12.2.4.1.1 + +evdMacroName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Name of this macro for use in data event equations" + ::= { evdMacroEntry 2 } + --1.3.6.1.4.1.3052.10.2.12.2.4.1.2 + +evdMacroEquation OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Equation for this data event macro" + ::= { evdMacroEntry 3 } + --1.3.6.1.4.1.3052.10.2.12.2.4.1.3 + +--*************************************************************************************** +--No data event 1 Section 2.12.3 +--*************************************************************************************** + +evNoData1Enable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF enable this no data event" + ::= { evNoData1 1 } + --1.3.6.1.4.1.3052.10.2.12.3.1 + +evNoData1Actions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Actions for this no data event" + ::= { evNoData1 2 } + --1.3.6.1.4.1.3052.10.2.12.3.2 + +evNoData1Message OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Message for this no data event" + ::= { evNoData1 3 } + --1.3.6.1.4.1.3052.10.2.12.3.3 + +evNoData1TrapNum OBJECT-TYPE + SYNTAX Integer32 (505..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Trap number for this no data event" + ::= { evNoData1 4 } + --1.3.6.1.4.1.3052.10.2.12.3.4 + +evNoData1Class OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Class for this no data event" + ::= { evNoData1 5 } + --1.3.6.1.4.1.3052.10.2.12.3.5 + +evNoData1Sched1Begin OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Schedule 1 begin time (HH:MM) for this no data event" + ::= { evNoData1 6 } + --1.3.6.1.4.1.3052.10.2.12.3.6 + +evNoData1Sched1End OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Schedule 1 end time (HH:MM) for this no data event" + ::= { evNoData1 7 } + --1.3.6.1.4.1.3052.10.2.12.3.7 + +evNoData1Sched1Duration OBJECT-TYPE + SYNTAX Integer32 (0..65535) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Duration (minutes) for schedule 1 of this no data event" + ::= { evNoData1 8 } + --1.3.6.1.4.1.3052.10.2.12.3.8 + +evNoData1Sched2Begin OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Schedule 2 begin time (HH:MM) for this no data event" + ::= { evNoData1 9 } + --1.3.6.1.4.1.3052.10.2.12.3.9 + +evNoData1Sched2End OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Schedule 2 end time (HH:MM) for this no data event" + ::= { evNoData1 10 } + --1.3.6.1.4.1.3052.10.2.12.3.10 + +evNoData1Sched2Duration OBJECT-TYPE + SYNTAX Integer32 (0..65535) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Duration (minutes) for schedule 2 of this no data event" + ::= { evNoData1 11 } + --1.3.6.1.4.1.3052.10.2.12.3.11 + +evNoData1PortEnableTable OBJECT-TYPE + SYNTAX SEQUENCE OF NoDataEvent1PortEnableConfig + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table of no data event 1 port enables" + ::= { evNoData1 12 } + --1.3.6.1.4.1.3052.10.2.12.3.12 + +evNoData1PortEnableEntry OBJECT-TYPE + SYNTAX NoDataEvent1PortEnableConfig + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry for table of no data event 1 port enables" + INDEX { evNoData1PortEnableIndex } + ::= { evNoData1PortEnableTable 1 } + --1.3.6.1.4.1.3052.10.2.12.3.12.1 + +evNoData1PortEnableIndex OBJECT-TYPE + SYNTAX Integer32 (1..16) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Index for table of no data event 1 port enables" + ::= { evNoData1PortEnableEntry 1 } + --1.3.6.1.4.1.3052.10.2.12.3.12.1.1 + +evNoData1PortEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF: no data event 1 observes this port" + ::= { evNoData1PortEnableEntry 2 } + --1.3.6.1.4.1.3052.10.2.12.3.12.1.2 + +evNoData1Exclusions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Exclusions (space-separated MM/DD-formatted dates) for this + no data event" + ::= { evNoData1 13 } + --1.3.6.1.4.1.3052.10.2.12.3.13 + +evNoData1Days OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Days of the week on which this no event is active" + ::= { evNoData1 14 } + --1.3.6.1.4.1.3052.10.2.12.3.14 + +--*************************************************************************************** +--No data event 2 Section 2.12.4 +--*************************************************************************************** + +evNoData2Enable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF enable this no data event" + ::= { evNoData2 1 } + --1.3.6.1.4.1.3052.10.2.12.4.1 + +evNoData2Actions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Actions for this no data event" + ::= { evNoData2 2 } + --1.3.6.1.4.1.3052.10.2.12.4.2 + +evNoData2Message OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Message for this no data event" + ::= { evNoData2 3 } + --1.3.6.1.4.1.3052.10.2.12.4.3 + +evNoData2TrapNum OBJECT-TYPE + SYNTAX Integer32 (505..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Trap number for this no data event" + ::= { evNoData2 4 } + --1.3.6.1.4.1.3052.10.2.12.4.4 + +evNoData2Class OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Class for this no data event" + ::= { evNoData2 5 } + --1.3.6.1.4.1.3052.10.2.12.4.5 + +evNoData2Sched1Begin OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Schedule 1 begin time (HH:MM) for this no data event" + ::= { evNoData2 6 } + --1.3.6.1.4.1.3052.10.2.12.4.6 + +evNoData2Sched1End OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Schedule 1 end time (HH:MM) for this no data event" + ::= { evNoData2 7 } + --1.3.6.1.4.1.3052.10.2.12.4.7 + +evNoData2Sched1Duration OBJECT-TYPE + SYNTAX Integer32 (0..65535) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Duration (minutes) for schedule 1 of this no data event" + ::= { evNoData2 8 } + --1.3.6.1.4.1.3052.10.2.12.4.8 + +evNoData2Sched2Begin OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Schedule 2 begin time (HH:MM) for this no data event" + ::= { evNoData2 9 } + --1.3.6.1.4.1.3052.10.2.12.4.9 + +evNoData2Sched2End OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Schedule 2 end time (HH:MM) for this no data event" + ::= { evNoData2 10 } + --1.3.6.1.4.1.3052.10.2.12.4.10 + +evNoData2Sched2Duration OBJECT-TYPE + SYNTAX Integer32 (0..65535) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Duration (minutes) for schedule 2 of this no data event" + ::= { evNoData2 11 } + --1.3.6.1.4.1.3052.10.2.12.4.11 + +evNoData2PortEnableTable OBJECT-TYPE + SYNTAX SEQUENCE OF NoDataEvent2PortEnableConfig + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table of no data event 2 port enables" + ::= { evNoData2 12 } + --1.3.6.1.4.1.3052.10.2.12.4.12 + +evNoData2PortEnableEntry OBJECT-TYPE + SYNTAX NoDataEvent2PortEnableConfig + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry for table of no data event 2 port enables" + INDEX { evNoData2PortEnableIndex } + ::= { evNoData2PortEnableTable 1 } + --1.3.6.1.4.1.3052.10.2.12.4.12.1 + +evNoData2PortEnableIndex OBJECT-TYPE + SYNTAX Integer32 (1..16) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Index for table of no data event 2 port enables" + ::= { evNoData2PortEnableEntry 1 } + --1.3.6.1.4.1.3052.10.2.12.4.12.1.1 + +evNoData2PortEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF: no data event 2 observes this port" + ::= { evNoData2PortEnableEntry 2 } + --1.3.6.1.4.1.3052.10.2.12.4.12.1.2 + +evNoData2Exclusions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Exclusions (space-separated MM/DD-formatted dates) for this + no data event" + ::= { evNoData2 13 } + --1.3.6.1.4.1.3052.10.2.12.4.13 + +evNoData2Days OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Days of the week on which this no event is active" + ::= { evNoData2 14 } + --1.3.6.1.4.1.3052.10.2.12.4.14 + +--*************************************************************************************** +--Scheduled Event 1 Section 2.12.5 +--*************************************************************************************** + +evSched1Enable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF enable this scheduled event" + ::= { evSched1 1 } + --1.3.6.1.4.1.3052.10.2.12.5.1 + +evSched1Actions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Actions for this scheduled event" + ::= { evSched1 2 } + --1.3.6.1.4.1.3052.10.2.12.5.2 + +evSched1Message OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Message for this scheduled event" + ::= { evSched1 3 } + --1.3.6.1.4.1.3052.10.2.12.5.3 + +evSched1TrapNum OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Trap number for this scheduled event" + ::= { evSched1 4 } + --1.3.6.1.4.1.3052.10.2.12.5.4 + +evSched1Class OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Class for this scheduled event" + ::= { evSched1 5 } + --1.3.6.1.4.1.3052.10.2.12.5.5 + +evSched1Sunday OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Time on Sunday (HH:MM) when this scheduled event triggers" + ::= { evSched1 6 } + --1.3.6.1.4.1.3052.10.2.12.5.6 + +evSched1Monday OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Time on Monday (HH:MM) when this scheduled event triggers" + ::= { evSched1 7 } + --1.3.6.1.4.1.3052.10.2.12.5.7 + +evSched1Tuesday OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Time on Tuesday (HH:MM) when this scheduled event triggers" + ::= { evSched1 8 } + --1.3.6.1.4.1.3052.10.2.12.5.8 + +evSched1Wednesday OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Time on Wednesday (HH:MM) when this scheduled event triggers" + ::= { evSched1 9 } + --1.3.6.1.4.1.3052.10.2.12.5.9 + +evSched1Thursday OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Time on Thursday (HH:MM) when this scheduled event triggers" + ::= { evSched1 10 } + --1.3.6.1.4.1.3052.10.2.12.5.10 + +evSched1Friday OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Time on Friday (HH:MM) when this scheduled event triggers" + ::= { evSched1 11 } + --1.3.6.1.4.1.3052.10.2.12.5.11 + +evSched1Saturday OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Time on Saturday (HH:MM) when this scheduled event triggers" + ::= { evSched1 12 } + --1.3.6.1.4.1.3052.10.2.12.5.12 + +evSched1Exclusions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Exclusions (space-separated MM/DD-formatted dates) for this + scheduled event" + ::= { evSched1 13 } + --1.3.6.1.4.1.3052.10.2.12.5.13 + + +--*************************************************************************************** +--Scheduled Event 2 Section 2.12.6 +--*************************************************************************************** + +evSched2Enable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF enable this scheduled event" + ::= { evSched2 1 } + --1.3.6.1.4.1.3052.10.2.12.6.1 + +evSched2Actions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Actions for this scheduled event" + ::= { evSched2 2 } + --1.3.6.1.4.1.3052.10.2.12.6.2 + +evSched2Message OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Message for this scheduled event" + ::= { evSched2 3 } + --1.3.6.1.4.1.3052.10.2.12.6.3 + +evSched2TrapNum OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Trap number for this scheduled event" + ::= { evSched2 4 } + --1.3.6.1.4.1.3052.10.2.12.6.4 + +evSched2Class OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Class for this scheduled event" + ::= { evSched2 5 } + --1.3.6.1.4.1.3052.10.2.12.6.5 + +evSched2Sunday OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Time on Sunday (HH:MM) when this scheduled event triggers" + ::= { evSched2 6 } + --1.3.6.1.4.1.3052.10.2.12.6.6 + +evSched2Monday OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Time on Monday (HH:MM) when this scheduled event triggers" + ::= { evSched2 7 } + --1.3.6.1.4.1.3052.10.2.12.6.7 + +evSched2Tuesday OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Time on Tuesday (HH:MM) when this scheduled event triggers" + ::= { evSched2 8 } + --1.3.6.1.4.1.3052.10.2.12.6.8 + +evSched2Wednesday OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Time on Wednesday (HH:MM) when this scheduled event triggers" + ::= { evSched2 9 } + --1.3.6.1.4.1.3052.10.2.12.6.9 + +evSched2Thursday OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Time on Thursday (HH:MM) when this scheduled event triggers" + ::= { evSched2 10 } + --1.3.6.1.4.1.3052.10.2.12.6.10 + +evSched2Friday OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Time on Friday (HH:MM) when this scheduled event triggers" + ::= { evSched2 11 } + --1.3.6.1.4.1.3052.10.2.12.6.11 + +evSched2Saturday OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Time on Saturday (HH:MM) when this scheduled event triggers" + ::= { evSched2 12 } + --1.3.6.1.4.1.3052.10.2.12.6.12 + +evSched2Exclusions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Exclusions (space-separated MM/DD-formatted dates) for this + scheduled event" + ::= { evSched2 13 } + --1.3.6.1.4.1.3052.10.2.12.6.13 + +--*************************************************************************************** +--Serial Handshaking Low Section 2.12.7 +--*************************************************************************************** + +evShskLowTable OBJECT-TYPE + SYNTAX SEQUENCE OF SerialHandshakingLowEventConfig + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table of serial handshaking low events" + ::= { event 7 } + --1.3.6.1.4.1.3052.10.2.12.7 + +evShskLowEntry OBJECT-TYPE + SYNTAX SerialHandshakingLowEventConfig + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry for table of serial handshaking low events" + INDEX { evShskLowIndex } + ::= { evShskLowTable 1 } + --1.3.6.1.4.1.3052.10.2.12.7.1 + +evShskLowIndex OBJECT-TYPE + SYNTAX Integer32 (1..16) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Index for table of serial handshaking low events" + ::= { evShskLowEntry 1 } + --1.3.6.1.4.1.3052.10.2.12.7.1.1 + +evShskLowEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF: enable the serial handshaking low event for this port" + ::= { evShskLowEntry 2 } + --1.3.6.1.4.1.3052.10.2.12.7.1.2 + +evShskLowActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Actions for the serial handshaking low event for this port" + ::= { evShskLowEntry 3 } + --1.3.6.1.4.1.3052.10.2.12.7.1.3 + +evShskLowMessage OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Message for the serial handshaking low event for this port" + ::= { evShskLowEntry 4 } + --1.3.6.1.4.1.3052.10.2.12.7.1.4 + +evShskLowClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Class for the serial handshaking low event for this port" + ::= { evShskLowEntry 5 } + --1.3.6.1.4.1.3052.10.2.12.7.1.5 + +evShskLowTrapNum OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Trap number for the serial handshaking low event for this port" + ::= { evShskLowEntry 6 } + --1.3.6.1.4.1.3052.10.2.12.7.1.6 + + +--*************************************************************************************** +--Serial Handshaking High Section 2.12.8 +--*************************************************************************************** + +evShskHighTable OBJECT-TYPE + SYNTAX SEQUENCE OF SerialHandshakingHighEventConfig + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table of serial handshaking high events" + ::= { event 8 } + --1.3.6.1.4.1.3052.10.2.12.8 + +evShskHighEntry OBJECT-TYPE + SYNTAX SerialHandshakingHighEventConfig + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry for table of serial handshaking high events" + INDEX { evShskHighIndex } + ::= { evShskHighTable 1 } + --1.3.6.1.4.1.3052.10.2.12.8.1 + +evShskHighIndex OBJECT-TYPE + SYNTAX Integer32 (1..16) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Index for table of serial handshaking high events" + ::= { evShskHighEntry 1 } + --1.3.6.1.4.1.3052.10.2.12.8.1.1 + +evShskHighEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF: enable the serial handshaking high event for this + port" + ::= { evShskHighEntry 2 } + --1.3.6.1.4.1.3052.10.2.12.8.1.2 + +evShskHighActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Actions for the serial handshaking high event for this port" + ::= { evShskHighEntry 3 } + --1.3.6.1.4.1.3052.10.2.12.8.1.3 + +evShskHighMessage OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Message for the serial handshaking high event for this port" + ::= { evShskHighEntry 4 } + --1.3.6.1.4.1.3052.10.2.12.8.1.4 + +evShskHighClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Class for the serial handshaking high event for this port" + ::= { evShskHighEntry 5 } + --1.3.6.1.4.1.3052.10.2.12.8.1.5 + +evShskHighTrapNum OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Trap number for the serial handshaking high event for this + port" + ::= { evShskHighEntry 6 } + --1.3.6.1.4.1.3052.10.2.12.8.1.6 + + + +--*************************************************************************************** +--No Sensor Event Section 2.12.9 +--*************************************************************************************** + +evNoSensorTimeout OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Timeout (seconds) after which an EventSensor becomes + unresponsive that this event is triggered" + ::= { evNoSensor 1 } + --1.3.6.1.4.1.3052.10.2.12.9.1 + +evNoSensorActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Actions for no sensor event" + ::= { evNoSensor 2 } + --1.3.6.1.4.1.3052.10.2.12.9.2 + +evNoSensorTrapNum OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Trap number for no sensor event" + ::= { evNoSensor 3 } + --1.3.6.1.4.1.3052.10.2.12.9.3 + +evNoSensorClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Class for no sensor event" + ::= { evNoSensor 4 } + --1.3.6.1.4.1.3052.10.2.12.9.4 + + + +--*************************************************************************************** +--Fuel Sensor Config Section 2.12.11 +--*************************************************************************************** + + +fuelSensorGeneralTable OBJECT-TYPE + SYNTAX SEQUENCE OF FuelSensorConfigGeneral + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table organizes general fuel sensor attributes." + ::= { fuelSensor 1 } + --1.3.6.1.4.1.3052.10.2.12.11.1 + +fsGenEntry OBJECT-TYPE + SYNTAX FuelSensorConfigGeneral + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry for fuel sensor general config table." + INDEX { fsGenIndex } + ::= { fuelSensorGeneralTable 1 } + --1.3.6.1.4.1.3052.10.2.12.11.1.1 + +fsGenIndex OBJECT-TYPE + SYNTAX Integer32 (1..3) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Which fuel sensor in the fuel sensor general config table." + ::= { fsGenEntry 1 } + --1.3.6.1.4.1.3052.10.2.12.11.1.1.1 + +fsGenName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Fuel sensor name." + ::= { fsGenEntry 2 } + --1.3.6.1.4.1.3052.10.2.12.11.1.1.2 + +fsGenSensorType OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Type of fuel sensor in use; NONE disables the fuel sensor." + ::= { fsGenEntry 3 } + --1.3.6.1.4.1.3052.10.2.12.11.1.1.3 + +fsGenDistanceUnit OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Distance units in use when setting and indicating tank dimensions." + ::= { fsGenEntry 4 } + --1.3.6.1.4.1.3052.10.2.12.11.1.1.4 + +fsGenRawValueTop OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Analog input reading corresponding to the SENSOR FULL point." + ::= { fsGenEntry 5 } + --1.3.6.1.4.1.3052.10.2.12.11.1.1.5 + +fsGenTopOffset OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Distance, in the specified distance unit, between the SENSOR FULL + point and the TANK FULL point. The value is positive if the + SENSOR FULL point is above the TANK FULL point, and negative if it is + below." + ::= { fsGenEntry 6 } + --1.3.6.1.4.1.3052.10.2.12.11.1.1.6 + +fsGenRawValueBottom OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Analog input reading corresponding to the minimum fluid height + measurable by the fuel sensor." + ::= { fsGenEntry 7 } + --1.3.6.1.4.1.3052.10.2.12.11.1.1.7 + +fsGenBottomOffset OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Distance, in the specified distance unit, between the SENSOR EMPTY + point and the TANK EMPTY point. The value is positive if the + SENSOR EMPTY point is above the TANK EMPTY point, and negative if it + is below." + ::= { fsGenEntry 8 } + --1.3.6.1.4.1.3052.10.2.12.11.1.1.8 + +fsGenInputES OBJECT-TYPE + SYNTAX Integer32 (1..200) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Which eventsensor contains the analog input associated with this fuel + sensor. Allowed values are 200 (for internal ES), or 1-16." + ::= { fsGenEntry 9 } + --1.3.6.1.4.1.3052.10.2.12.11.1.1.9 + +fsGenInputPoint OBJECT-TYPE + SYNTAX Integer32 (1..16) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Which analog input point, on the specified eventsensor, that is + associated with the fuel sensor." + ::= { fsGenEntry 10 } + --1.3.6.1.4.1.3052.10.2.12.11.1.1.10 + +fsGenFilterAveraging OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Fuel sensor filter averaging factor." + ::= { fsGenEntry 11 } + --1.3.6.1.4.1.3052.10.2.12.11.1.1.11 + +fsGenSysrepEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Fuel sensor System Reporting enable." + ::= { fsGenEntry 12 } + --1.3.6.1.4.1.3052.10.2.12.11.1.1.12 + +fsGenSysrepThreshold OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Fuel sensor System Reporting threshold (floating point value)." + ::= { fsGenEntry 13 } + --1.3.6.1.4.1.3052.10.2.12.11.1.1.13 + +fsGenSysrepLimit OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Fuel sensor System Reporting limit." + ::= { fsGenEntry 14 } + --1.3.6.1.4.1.3052.10.2.12.11.1.1.14 + +fsGenSysrepPackage OBJECT-TYPE + SYNTAX Integer32 (0..10) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Fuel sensor System Reporting package number." + ::= { fsGenEntry 15 } + --1.3.6.1.4.1.3052.10.2.12.11.1.1.15 + +fsGenGroup OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Fuel sensor ASM profile type." + ::= { fsGenEntry 16 } + --1.3.6.1.4.1.3052.10.2.12.11.1.1.16 + +fsGenEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Fuel sensor enable." + ::= { fsGenEntry 17 } + --1.3.6.1.4.1.3052.10.2.12.11.1.1.17 + +fsGenFuelType OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Type of fuel being measured: DIESEL, PROPANE, + NATURAL GAS, HYDROGEN, GASOLINE, OTHER." + ::= { fsGenEntry 18 } + --1.3.6.1.4.1.3052.10.2.12.11.1.1.18 + +fuelSensorTankTable OBJECT-TYPE + SYNTAX SEQUENCE OF FuelSensorConfigTank + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table organizes tank-specific fuel sensor attributes." + ::= { fuelSensor 2 } + --1.3.6.1.4.1.3052.10.2.12.11.2 + +fsTankEntry OBJECT-TYPE + SYNTAX FuelSensorConfigTank + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry for fuel sensor tank config table." + INDEX { fsTankIndex } + ::= { fuelSensorTankTable 1 } + --1.3.6.1.4.1.3052.10.2.12.11.2.1 + +fsTankIndex OBJECT-TYPE + SYNTAX Integer32 (1..3) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Which fuel sensor in the fuel sensor tank config table." + ::= { fsTankEntry 1 } + --1.3.6.1.4.1.3052.10.2.12.11.2.1.1 + +fsTankHeight OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Height of the tank, from the TANK EMPTY point to the TANK FULL point, + in the specified distance unit (i.e. TANK HEIGHT). This is a + floating point value." + ::= { fsTankEntry 2 } + --1.3.6.1.4.1.3052.10.2.12.11.2.1.2 + +fsTankDimA OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Tank dimension measurement A for certain tank profiles. For + HORIZ OVAL, this is the length of the straight section. This is a + floating point value." + ::= { fsTankEntry 3 } + --1.3.6.1.4.1.3052.10.2.12.11.2.1.3 + +fsTankDimB OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Tank dimension measurement B for certain tank profiles. For + HORIZ OVAL, this is the radius of the curved section. This is a + floating point value." + ::= { fsTankEntry 4 } + --1.3.6.1.4.1.3052.10.2.12.11.2.1.4 + +fsTankVolume OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "How many volume units the tank contains, when full. This is a + floating point value." + ::= { fsTankEntry 5 } + --1.3.6.1.4.1.3052.10.2.12.11.2.1.5 + +fsTankVolumeUnit OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Name of the unit representing fluid volume in the tank. This is only + used for display purposes; it does not affect the volume calculation." + ::= { fsTankEntry 6 } + --1.3.6.1.4.1.3052.10.2.12.11.2.1.6 + +fsTankShape OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The shape of the fuel tank. A value of LINEAR produces a fluid + volume reading that is directly proportional to fluid height. The + HORIZ CYL and HORIZ OVAL settings use a hard-coded formula to + calculate the volume. The CUSTOM setting uses a strapping table that + must be configured as well (see fuelSensorCustomTankTable)." + ::= { fsTankEntry 7 } + --1.3.6.1.4.1.3052.10.2.12.11.2.1.7 + + +fuelSensorCustomTankTable OBJECT-TYPE + SYNTAX SEQUENCE OF FuelSensorConfigCustomTankStrapping + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table organizes the custom tank strapping table. Each fuel + sensor has a table of height/volume pairs in service only when the tank + shape (fsTankShape) in CUSTOM. This allows the unit to calculate + volumes for nonstandard tank shapes, to the degree that accurate + height/volume measurements can be configured. This SNMP table has two + indexes: the first for which fuel sensor and the second for which + height/volume pair." + ::= { fuelSensor 3 } + --1.3.6.1.4.1.3052.10.2.12.11.3 + +fsCustomTankEntry OBJECT-TYPE + SYNTAX FuelSensorConfigCustomTankStrapping + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry for fuel sensor custom tank config table." + INDEX { fsCustomTankIndexFS, fsCustomTankIndexDatum } + ::= { fuelSensorCustomTankTable 1 } + --1.3.6.1.4.1.3052.10.2.12.11.3.1 + +fsCustomTankIndexFS OBJECT-TYPE + SYNTAX Integer32 (1..3) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Which fuel sensor in the fuel sensor tank config table. This is the + first of two indexes for this SNMP table." + ::= { fsCustomTankEntry 1 } + --1.3.6.1.4.1.3052.10.2.12.11.3.1.1 + +fsCustomTankIndexDatum OBJECT-TYPE + SYNTAX Integer32 (1..32) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Which hight/volume pair: there are 32 pairs per fuel sensor. This is + the second of two indexes for this SNMP table." + ::= { fsCustomTankEntry 2 } + --1.3.6.1.4.1.3052.10.2.12.11.3.1.2 + +fsCustomTankHeight OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Height of custom tank height/volume pair. This is a floating point + value." + ::= { fsCustomTankEntry 3 } + --1.3.6.1.4.1.3052.10.2.12.11.3.1.3 + +fsCustomTankVolume OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Volume of custom tank height/volume pair. This is a floating point + value." + ::= { fsCustomTankEntry 4 } + --1.3.6.1.4.1.3052.10.2.12.11.3.1.4 + + +fuelSensorVolumeTable OBJECT-TYPE + SYNTAX SEQUENCE OF FuelSensorConfigVolume + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table organizes volume-event-specific fuel sensor attributes." + ::= { fuelSensor 4 } + --1.3.6.1.4.1.3052.10.2.12.11.4 + +fsVolumeEntry OBJECT-TYPE + SYNTAX FuelSensorConfigVolume + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry for fuel sensor volume event config table." + INDEX { fsVolumeIndex } + ::= { fuelSensorVolumeTable 1 } + --1.3.6.1.4.1.3052.10.2.12.11.4.1 + +fsVolumeIndex OBJECT-TYPE + SYNTAX Integer32 (1..3) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Which fuel sensor in the fuel sensor volume event config table." + ::= { fsVolumeEntry 1 } + --1.3.6.1.4.1.3052.10.2.12.11.4.1.1 + +fsVolumeEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable fuel sensor volume events." + ::= { fsVolumeEntry 2 } + --1.3.6.1.4.1.3052.10.2.12.11.4.1.2 + +fsVolumeDeadband OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Fuel sensor deadband (hysteresis). This is a floating point value." + ::= { fsVolumeEntry 3 } + --1.3.6.1.4.1.3052.10.2.12.11.4.1.3 + +fsVolumeVHighValue OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Fuel sensor volume very high event threshold value. This is a + floating point value." + ::= { fsVolumeEntry 4 } + --1.3.6.1.4.1.3052.10.2.12.11.4.1.4 + +fsVolumeVHighActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Fuel sensor volume very high event threshold actions." + ::= { fsVolumeEntry 5 } + --1.3.6.1.4.1.3052.10.2.12.11.4.1.5 + +fsVolumeVHighTrapNum OBJECT-TYPE + SYNTAX Integer32 (519..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Fuel sensor volume very high event threshold trap number." + ::= { fsVolumeEntry 6 } + --1.3.6.1.4.1.3052.10.2.12.11.4.1.6 + +fsVolumeVHighClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Fuel sensor volume very high event threshold class (severity)." + ::= { fsVolumeEntry 7 } + --1.3.6.1.4.1.3052.10.2.12.11.4.1.7 + +fsVolumeHighValue OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Fuel sensor volume high event threshold value. This is a floating + point value." + ::= { fsVolumeEntry 8 } + --1.3.6.1.4.1.3052.10.2.12.11.4.1.8 + +fsVolumeHighActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Fuel sensor volume high event threshold actions." + ::= { fsVolumeEntry 9 } + --1.3.6.1.4.1.3052.10.2.12.11.4.1.9 + +fsVolumeHighTrapNum OBJECT-TYPE + SYNTAX Integer32 (519..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Fuel sensor volume high event threshold trap number." + ::= { fsVolumeEntry 10 } + --1.3.6.1.4.1.3052.10.2.12.11.4.1.10 + +fsVolumeHighClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Fuel sensor volume high event threshold class (severity)." + ::= { fsVolumeEntry 11 } + --1.3.6.1.4.1.3052.10.2.12.11.4.1.11 + +fsVolumeNormalActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Fuel sensor volume return to normal actions." + ::= { fsVolumeEntry 12 } + --1.3.6.1.4.1.3052.10.2.12.11.4.1.12 + +fsVolumeNormalTrapNum OBJECT-TYPE + SYNTAX Integer32 (519..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Fuel sensor volume return to normal trap number." + ::= { fsVolumeEntry 13 } + --1.3.6.1.4.1.3052.10.2.12.11.4.1.13 + +fsVolumeNormalClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Fuel sensor volume return to normal class (severity)." + ::= { fsVolumeEntry 14 } + --1.3.6.1.4.1.3052.10.2.12.11.4.1.14 + +fsVolumeLowValue OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Fuel sensor volume low event threshold value. This is a floating + point value." + ::= { fsVolumeEntry 15 } + --1.3.6.1.4.1.3052.10.2.12.11.4.1.15 + +fsVolumeLowActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Fuel sensor volume low event threshold actions." + ::= { fsVolumeEntry 16 } + --1.3.6.1.4.1.3052.10.2.12.11.4.1.16 + +fsVolumeLowTrapNum OBJECT-TYPE + SYNTAX Integer32 (519..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Fuel sensor volume low event threshold trap number." + ::= { fsVolumeEntry 17 } + --1.3.6.1.4.1.3052.10.2.12.11.4.1.17 + +fsVolumeLowClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Fuel sensor volume low event threshold class (severity)." + ::= { fsVolumeEntry 18 } + --1.3.6.1.4.1.3052.10.2.12.11.4.1.18 + +fsVolumeVLowValue OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Fuel sensor volume very low event threshold value. This is a + floating point value." + ::= { fsVolumeEntry 19 } + --1.3.6.1.4.1.3052.10.2.12.11.4.1.19 + +fsVolumeVLowActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Fuel sensor volume very low event threshold actions." + ::= { fsVolumeEntry 20 } + --1.3.6.1.4.1.3052.10.2.12.11.4.1.20 + +fsVolumeVLowTrapNum OBJECT-TYPE + SYNTAX Integer32 (519..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Fuel sensor volume very low event threshold trap number." + ::= { fsVolumeEntry 21 } + --1.3.6.1.4.1.3052.10.2.12.11.4.1.21 + +fsVolumeVLowClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Fuel sensor volume very low event threshold class (severity)." + ::= { fsVolumeEntry 22 } + --1.3.6.1.4.1.3052.10.2.12.11.4.1.22 + + + +fuelSensorDisconnectTable OBJECT-TYPE + SYNTAX SEQUENCE OF FuelSensorConfigDisconnect + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table organizes disconnect-event-specific fuel sensor attributes." + ::= { fuelSensor 5 } + --1.3.6.1.4.1.3052.10.2.12.11.5 + +fsDiscEntry OBJECT-TYPE + SYNTAX FuelSensorConfigDisconnect + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry for fuel sensor disconnect event config table." + INDEX { fsDiscIndex } + ::= { fuelSensorDisconnectTable 1 } + --1.3.6.1.4.1.3052.10.2.12.11.5.1 + +fsDiscIndex OBJECT-TYPE + SYNTAX Integer32 (1..3) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Which fuel sensor in the fuel sensor disconnect event config table." + ::= { fsDiscEntry 1 } + --1.3.6.1.4.1.3052.10.2.12.11.5.1.1 + +fsDiscEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Fuel sensor disconnect event enable." + ::= { fsDiscEntry 2 } + --1.3.6.1.4.1.3052.10.2.12.11.5.1.2 + +fsDiscHighValue OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "High end of input value range when fuel sensor is disconnected. This + is in the units of the analog input value." + ::= { fsDiscEntry 3 } + --1.3.6.1.4.1.3052.10.2.12.11.5.1.3 + +fsDiscLowValue OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Low end of input value range when fuel sensor is disconnected. This + is in the units of the analog input value." + ::= { fsDiscEntry 4 } + --1.3.6.1.4.1.3052.10.2.12.11.5.1.4 + +fsDiscActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Fuel sensor disconnect event actions." + ::= { fsDiscEntry 5 } + --1.3.6.1.4.1.3052.10.2.12.11.5.1.5 + +fsDiscTrapNum OBJECT-TYPE + SYNTAX Integer32 (515..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Fuel sensor disconnect event trap number." + ::= { fsDiscEntry 6 } + --1.3.6.1.4.1.3052.10.2.12.11.5.1.6 + +fsDiscClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Fuel sensor disconnect event class (severity)." + ::= { fsDiscEntry 7 } + --1.3.6.1.4.1.3052.10.2.12.11.5.1.7 + +fsDiscNormalActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Fuel sensor disconnect return to normal actions." + ::= { fsDiscEntry 8 } + --1.3.6.1.4.1.3052.10.2.12.11.5.1.8 + +fsDiscNormalTrapNum OBJECT-TYPE + SYNTAX Integer32 (515..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Fuel sensor disconnect return to normal trap number." + ::= { fsDiscEntry 9 } + --1.3.6.1.4.1.3052.10.2.12.11.5.1.9 + +fsDiscNormalClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Fuel sensor disconnect return to normal class (severity)." + ::= { fsDiscEntry 10 } + --1.3.6.1.4.1.3052.10.2.12.11.5.1.10 + + +fuelSensorSuddenChangeTable OBJECT-TYPE + SYNTAX SEQUENCE OF FuelSensorConfigSuddenChange + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table organizes sudden-change-event-specific fuel sensor + attributes." + ::= { fuelSensor 6 } + --1.3.6.1.4.1.3052.10.2.12.11.6 + +fsSuddenChangeEntry OBJECT-TYPE + SYNTAX FuelSensorConfigSuddenChange + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry for fuel sensor sudden change event config table." + INDEX { fsSuddenChangeIndex } + ::= { fuelSensorSuddenChangeTable 1 } + --1.3.6.1.4.1.3052.10.2.12.11.6.1 + +fsSuddenChangeIndex OBJECT-TYPE + SYNTAX Integer32 (1..3) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Which fuel sensor in the fuel sensor sudden change event + config table." + ::= { fsSuddenChangeEntry 1 } + --1.3.6.1.4.1.3052.10.2.12.11.6.1.1 + +fsSuddenChangeEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Fuel volume sudden change event enable." + ::= { fsSuddenChangeEntry 2 } + --1.3.6.1.4.1.3052.10.2.12.11.6.1.2 + +fsSuddenChangeTime OBJECT-TYPE + SYNTAX Integer32 (5..360) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Fuel volume sudden change event time (minutes): what duration defines + 'sudden'." + ::= { fsSuddenChangeEntry 3 } + --1.3.6.1.4.1.3052.10.2.12.11.6.1.3 + +fsSuddenChangeAmplitude OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Fuel volume sudden change event amplitude: what amount (in fuel + volume units) over the duration (fsSuddenChangeTime) defines enough + change." + ::= { fsSuddenChangeEntry 4 } + --1.3.6.1.4.1.3052.10.2.12.11.6.1.4 + +fsSuddenChangeActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Fuel volume sudden change event actions." + ::= { fsSuddenChangeEntry 5 } + --1.3.6.1.4.1.3052.10.2.12.11.6.1.5 + +fsSuddenChangeTrapNum OBJECT-TYPE + SYNTAX Integer32 (527..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Fuel volume sudden change event trap number." + ::= { fsSuddenChangeEntry 6 } + --1.3.6.1.4.1.3052.10.2.12.11.6.1.6 + +fsSuddenChangeClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Fuel volume sudden change event class (severity)." + ::= { fsSuddenChangeEntry 7 } + --1.3.6.1.4.1.3052.10.2.12.11.6.1.7 + + +fuelSensorSlowChangeTable OBJECT-TYPE + SYNTAX SEQUENCE OF FuelSensorConfigSlowChange + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table organizes slow-change-event-specific fuel sensor attributes." + ::= { fuelSensor 7 } + --1.3.6.1.4.1.3052.10.2.12.11.7 + +fsSlowChangeEntry OBJECT-TYPE + SYNTAX FuelSensorConfigSlowChange + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry for fuel sensor slow change event config table." + INDEX { fsSlowChangeIndex } + ::= { fuelSensorSlowChangeTable 1 } + --1.3.6.1.4.1.3052.10.2.12.11.7.1 + +fsSlowChangeIndex OBJECT-TYPE + SYNTAX Integer32 (1..3) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Which fuel sensor in the fuel sensor slow change event + config table." + ::= { fsSlowChangeEntry 1 } + --1.3.6.1.4.1.3052.10.2.12.11.7.1.1 + +fsSlowChangeEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Fuel volume slow change event enable." + ::= { fsSlowChangeEntry 2 } + --1.3.6.1.4.1.3052.10.2.12.11.7.1.2 + +fsSlowChangeTime OBJECT-TYPE + SYNTAX Integer32 (1..168) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Fuel volume slow change event time (minutes): what duration defines + 'slow'." + ::= { fsSlowChangeEntry 3 } + --1.3.6.1.4.1.3052.10.2.12.11.7.1.3 + +fsSlowChangeAmplitude OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Fuel volume slow change event amplitude: what amount (in fuel volume + units) over the duration (fsSlowChangeTime) defines enough change." + ::= { fsSlowChangeEntry 4 } + --1.3.6.1.4.1.3052.10.2.12.11.7.1.4 + +fsSlowChangeActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Fuel volume slow change event actions." + ::= { fsSlowChangeEntry 5 } + --1.3.6.1.4.1.3052.10.2.12.11.7.1.5 + +fsSlowChangeTrapNum OBJECT-TYPE + SYNTAX Integer32 (528..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Fuel volume slow change event trap number." + ::= { fsSlowChangeEntry 6 } + --1.3.6.1.4.1.3052.10.2.12.11.7.1.6 + +fsSlowChangeClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Fuel volume slow change event class (severity)." + ::= { fsSlowChangeEntry 7 } + --1.3.6.1.4.1.3052.10.2.12.11.7.1.7 + + +--*************************************************************************************** +--AC Power Monitor Config Section 2.12.12 +--*************************************************************************************** + +acpmGeneralTable OBJECT-TYPE + SYNTAX SEQUENCE OF ACPMConfigGeneral + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table organizes general AC power monitor attributes." + ::= { acPowerMonitor 1 } + --1.3.6.1.4.1.3052.10.2.12.12.1 + +acpmGenEntry OBJECT-TYPE + SYNTAX ACPMConfigGeneral + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry for AC power monitor general config table." + INDEX { acpmGenIndex } + ::= { acpmGeneralTable 1 } + --1.3.6.1.4.1.3052.10.2.12.12.1.1 + +acpmGenIndex OBJECT-TYPE + SYNTAX Integer32 (1..6) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Which AC power monitor in the AC power monitor general config table." + ::= { acpmGenEntry 1 } + --1.3.6.1.4.1.3052.10.2.12.12.1.1.1 + +acpmGenDevice OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Model of the AC power monitor device. The unit needs this setting to + know which registers to poll for the various data items, among other + things." + ::= { acpmGenEntry 2 } + --1.3.6.1.4.1.3052.10.2.12.12.1.1.2 + +acpmGenName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Name for the AC power monitor device." + ::= { acpmGenEntry 3 } + --1.3.6.1.4.1.3052.10.2.12.12.1.1.3 + +acpmGenAddress OBJECT-TYPE + SYNTAX Integer32 (1..247) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Modbus address of the AC power monitor device." + ::= { acpmGenEntry 4 } + --1.3.6.1.4.1.3052.10.2.12.12.1.1.4 + +acpmGenPtRatio OBJECT-TYPE + SYNTAX Integer32 (1..10000) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Ratio of secondary turns to primary turns on potential transformers + (PT)." + ::= { acpmGenEntry 5 } + --1.3.6.1.4.1.3052.10.2.12.12.1.1.5 + +acpmGenCtRatio OBJECT-TYPE + SYNTAX Integer32 (1..10000) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Ratio of secondary turns to primary turns on current transformers + (CT)." + ::= { acpmGenEntry 6 } + --1.3.6.1.4.1.3052.10.2.12.12.1.1.6 + +acpmGenPowerType OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Type of power being monitored." + ::= { acpmGenEntry 7 } + --1.3.6.1.4.1.3052.10.2.12.12.1.1.7 + +acpmGenSysrepPackage OBJECT-TYPE + SYNTAX Integer32 (0..10) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "System reporting package number." + ::= { acpmGenEntry 8 } + --1.3.6.1.4.1.3052.10.2.12.12.1.1.8 + +acpmGenGroup OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ASM profile group." + ::= { acpmGenEntry 9 } + --1.3.6.1.4.1.3052.10.2.12.12.1.1.9 + +acpmGenEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "AC power monitor enable." + ::= { acpmGenEntry 10 } + --1.3.6.1.4.1.3052.10.2.12.12.1.1.10 + + +acpmAvgVoltageTable OBJECT-TYPE + SYNTAX SEQUENCE OF ACPMConfigAvgVoltage + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table organizes AC power monitor average voltage attributes." + ::= { acPowerMonitor 2 } + --1.3.6.1.4.1.3052.10.2.12.12.2 + +acpmAvgVoltageEntry OBJECT-TYPE + SYNTAX ACPMConfigAvgVoltage + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry for AC power monitor average voltage config table." + INDEX { acpmAvgVoltageIndex } + ::= { acpmAvgVoltageTable 1 } + --1.3.6.1.4.1.3052.10.2.12.12.2.1 + +acpmAvgVoltageIndex OBJECT-TYPE + SYNTAX Integer32 (1..6) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Which AC power monitor in the AC power monitor average voltage config + table." + ::= { acpmAvgVoltageEntry 1 } + --1.3.6.1.4.1.3052.10.2.12.12.2.1.1 + +acpmAvgVoltageEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable AC power monitor average voltage events." + ::= { acpmAvgVoltageEntry 2 } + --1.3.6.1.4.1.3052.10.2.12.12.2.1.2 + +acpmAvgVoltageDeadband OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Deadband (hysteresis) for average voltage event. This is a floating + point value." + ::= { acpmAvgVoltageEntry 3 } + --1.3.6.1.4.1.3052.10.2.12.12.2.1.3 + +acpmAvgVoltageVHighValue OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Very high event threshold. This is a floating point value." + ::= { acpmAvgVoltageEntry 4 } + --1.3.6.1.4.1.3052.10.2.12.12.2.1.4 + +acpmAvgVoltageVHighActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Very high event actions." + ::= { acpmAvgVoltageEntry 5 } + --1.3.6.1.4.1.3052.10.2.12.12.2.1.5 + +acpmAvgVoltageVHighTrapNum OBJECT-TYPE + SYNTAX Integer32 (520..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Very high event trap number." + ::= { acpmAvgVoltageEntry 6 } + --1.3.6.1.4.1.3052.10.2.12.12.2.1.6 + +acpmAvgVoltageVHighClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Very high event class." + ::= { acpmAvgVoltageEntry 7 } + --1.3.6.1.4.1.3052.10.2.12.12.2.1.7 + +acpmAvgVoltageHighValue OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "High event threshold. This is a floating point value." + ::= { acpmAvgVoltageEntry 8 } + --1.3.6.1.4.1.3052.10.2.12.12.2.1.8 + +acpmAvgVoltageHighActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "High event actions." + ::= { acpmAvgVoltageEntry 9 } + --1.3.6.1.4.1.3052.10.2.12.12.2.1.9 + +acpmAvgVoltageHighTrapNum OBJECT-TYPE + SYNTAX Integer32 (520..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "High event trap number." + ::= { acpmAvgVoltageEntry 10 } + --1.3.6.1.4.1.3052.10.2.12.12.2.1.10 + +acpmAvgVoltageHighClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "High event class." + ::= { acpmAvgVoltageEntry 11 } + --1.3.6.1.4.1.3052.10.2.12.12.2.1.11 + +acpmAvgVoltageNormalActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Return to normal actions." + ::= { acpmAvgVoltageEntry 12 } + --1.3.6.1.4.1.3052.10.2.12.12.2.1.12 + +acpmAvgVoltageNormalTrapNum OBJECT-TYPE + SYNTAX Integer32 (520..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Return to normal trap number." + ::= { acpmAvgVoltageEntry 13 } + --1.3.6.1.4.1.3052.10.2.12.12.2.1.13 + +acpmAvgVoltageNormalClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Return to normal class." + ::= { acpmAvgVoltageEntry 14 } + --1.3.6.1.4.1.3052.10.2.12.12.2.1.14 + +acpmAvgVoltageLowValue OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Low event threshold. This is a floating point value." + ::= { acpmAvgVoltageEntry 15 } + --1.3.6.1.4.1.3052.10.2.12.12.2.1.15 + +acpmAvgVoltageLowActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Low event actions." + ::= { acpmAvgVoltageEntry 16 } + --1.3.6.1.4.1.3052.10.2.12.12.2.1.16 + +acpmAvgVoltageLowTrapNum OBJECT-TYPE + SYNTAX Integer32 (520..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Low event trap number." + ::= { acpmAvgVoltageEntry 17 } + --1.3.6.1.4.1.3052.10.2.12.12.2.1.17 + +acpmAvgVoltageLowClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Low event class." + ::= { acpmAvgVoltageEntry 18 } + --1.3.6.1.4.1.3052.10.2.12.12.2.1.18 + +acpmAvgVoltageVLowValue OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Very low event threshold. This is a floating point value." + ::= { acpmAvgVoltageEntry 19 } + --1.3.6.1.4.1.3052.10.2.12.12.2.1.19 + +acpmAvgVoltageVLowActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Very low event actions." + ::= { acpmAvgVoltageEntry 20 } + --1.3.6.1.4.1.3052.10.2.12.12.2.1.20 + +acpmAvgVoltageVLowTrapNum OBJECT-TYPE + SYNTAX Integer32 (520..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Very low event trap number." + ::= { acpmAvgVoltageEntry 21 } + --1.3.6.1.4.1.3052.10.2.12.12.2.1.21 + +acpmAvgVoltageVLowClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Very low event class." + ::= { acpmAvgVoltageEntry 22 } + --1.3.6.1.4.1.3052.10.2.12.12.2.1.22 + +acpmAvgVoltageSysrepEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "System reporting enable for average voltage telemetry." + ::= { acpmAvgVoltageEntry 23 } + --1.3.6.1.4.1.3052.10.2.12.12.2.1.23 + +acpmAvgVoltageSysrepThreshold OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "System reporting threshold for average voltage telemetry. This is a + floating point value." + ::= { acpmAvgVoltageEntry 24 } + --1.3.6.1.4.1.3052.10.2.12.12.2.1.24 + +acpmAvgVoltageSysrepLimit OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "System reporting limit for average voltage telemetry." + ::= { acpmAvgVoltageEntry 25 } + --1.3.6.1.4.1.3052.10.2.12.12.2.1.25 + + +acpmAvgCurrentTable OBJECT-TYPE + SYNTAX SEQUENCE OF ACPMConfigAvgCurrent + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table organizes AC power monitor average current attributes." + ::= { acPowerMonitor 3 } + --1.3.6.1.4.1.3052.10.2.12.12.3 + +acpmAvgCurrentEntry OBJECT-TYPE + SYNTAX ACPMConfigAvgCurrent + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry for AC power monitor average current config table." + INDEX { acpmAvgCurrentIndex } + ::= { acpmAvgCurrentTable 1 } + --1.3.6.1.4.1.3052.10.2.12.12.3.1 + +acpmAvgCurrentIndex OBJECT-TYPE + SYNTAX Integer32 (1..6) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Which AC power monitor in the AC power monitor average current config + table." + ::= { acpmAvgCurrentEntry 1 } + --1.3.6.1.4.1.3052.10.2.12.12.3.1.1 + +acpmAvgCurrentEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable AC power monitor average current events." + ::= { acpmAvgCurrentEntry 2 } + --1.3.6.1.4.1.3052.10.2.12.12.3.1.2 + +acpmAvgCurrentDeadband OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Deadband (hysteresis) for average current event. This is a floating + point value." + ::= { acpmAvgCurrentEntry 3 } + --1.3.6.1.4.1.3052.10.2.12.12.3.1.3 + +acpmAvgCurrentVHighValue OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Very high event threshold. This is a floating point value." + ::= { acpmAvgCurrentEntry 4 } + --1.3.6.1.4.1.3052.10.2.12.12.3.1.4 + +acpmAvgCurrentVHighActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Very high event actions." + ::= { acpmAvgCurrentEntry 5 } + --1.3.6.1.4.1.3052.10.2.12.12.3.1.5 + +acpmAvgCurrentVHighTrapNum OBJECT-TYPE + SYNTAX Integer32 (521..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Very high event trap number." + ::= { acpmAvgCurrentEntry 6 } + --1.3.6.1.4.1.3052.10.2.12.12.3.1.6 + +acpmAvgCurrentVHighClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Very high event class." + ::= { acpmAvgCurrentEntry 7 } + --1.3.6.1.4.1.3052.10.2.12.12.3.1.7 + +acpmAvgCurrentHighValue OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "High event threshold. This is a floating point value." + ::= { acpmAvgCurrentEntry 8 } + --1.3.6.1.4.1.3052.10.2.12.12.3.1.8 + +acpmAvgCurrentHighActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "High event actions." + ::= { acpmAvgCurrentEntry 9 } + --1.3.6.1.4.1.3052.10.2.12.12.3.1.9 + +acpmAvgCurrentHighTrapNum OBJECT-TYPE + SYNTAX Integer32 (521..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "High event trap number." + ::= { acpmAvgCurrentEntry 10 } + --1.3.6.1.4.1.3052.10.2.12.12.3.1.10 + +acpmAvgCurrentHighClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "High event class." + ::= { acpmAvgCurrentEntry 11 } + --1.3.6.1.4.1.3052.10.2.12.12.3.1.11 + +acpmAvgCurrentNormalActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Return to normal actions." + ::= { acpmAvgCurrentEntry 12 } + --1.3.6.1.4.1.3052.10.2.12.12.3.1.12 + +acpmAvgCurrentNormalTrapNum OBJECT-TYPE + SYNTAX Integer32 (521..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Return to normal trap number." + ::= { acpmAvgCurrentEntry 13 } + --1.3.6.1.4.1.3052.10.2.12.12.3.1.13 + +acpmAvgCurrentNormalClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Return to normal class." + ::= { acpmAvgCurrentEntry 14 } + --1.3.6.1.4.1.3052.10.2.12.12.3.1.14 + +acpmAvgCurrentLowValue OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Low event threshold. This is a floating point value." + ::= { acpmAvgCurrentEntry 15 } + --1.3.6.1.4.1.3052.10.2.12.12.3.1.15 + +acpmAvgCurrentLowActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Low event actions." + ::= { acpmAvgCurrentEntry 16 } + --1.3.6.1.4.1.3052.10.2.12.12.3.1.16 + +acpmAvgCurrentLowTrapNum OBJECT-TYPE + SYNTAX Integer32 (521..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Low event trap number." + ::= { acpmAvgCurrentEntry 17 } + --1.3.6.1.4.1.3052.10.2.12.12.3.1.17 + +acpmAvgCurrentLowClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Low event class." + ::= { acpmAvgCurrentEntry 18 } + --1.3.6.1.4.1.3052.10.2.12.12.3.1.18 + +acpmAvgCurrentVLowValue OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Very low event threshold. This is a floating point value." + ::= { acpmAvgCurrentEntry 19 } + --1.3.6.1.4.1.3052.10.2.12.12.3.1.19 + +acpmAvgCurrentVLowActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Very low event actions." + ::= { acpmAvgCurrentEntry 20 } + --1.3.6.1.4.1.3052.10.2.12.12.3.1.20 + +acpmAvgCurrentVLowTrapNum OBJECT-TYPE + SYNTAX Integer32 (521..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Very low event trap number." + ::= { acpmAvgCurrentEntry 21 } + --1.3.6.1.4.1.3052.10.2.12.12.3.1.21 + +acpmAvgCurrentVLowClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Very low event class." + ::= { acpmAvgCurrentEntry 22 } + --1.3.6.1.4.1.3052.10.2.12.12.3.1.22 + +acpmAvgCurrentSysrepEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "System reporting enable for average current telemetry." + ::= { acpmAvgCurrentEntry 23 } + --1.3.6.1.4.1.3052.10.2.12.12.3.1.23 + +acpmAvgCurrentSysrepThreshold OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "System reporting threshold for average current telemetry. This is + a floating point value." + ::= { acpmAvgCurrentEntry 24 } + --1.3.6.1.4.1.3052.10.2.12.12.3.1.24 + +acpmAvgCurrentSysrepLimit OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "System reporting limit for average current telemetry." + ::= { acpmAvgCurrentEntry 25 } + --1.3.6.1.4.1.3052.10.2.12.12.3.1.25 + + +acpmFreqTable OBJECT-TYPE + SYNTAX SEQUENCE OF ACPMConfigFreq + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table organizes AC power monitor frequency attributes." + ::= { acPowerMonitor 4 } + --1.3.6.1.4.1.3052.10.2.12.12.4 + +acpmFreqEntry OBJECT-TYPE + SYNTAX ACPMConfigFreq + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry for AC power monitor frequency config table." + INDEX { acpmFreqIndex } + ::= { acpmFreqTable 1 } + --1.3.6.1.4.1.3052.10.2.12.12.4.1 + +acpmFreqIndex OBJECT-TYPE + SYNTAX Integer32 (1..6) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Which AC power monitor in the AC power monitor frequency config table." + ::= { acpmFreqEntry 1 } + --1.3.6.1.4.1.3052.10.2.12.12.4.1.1 + +acpmFreqEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable AC power monitor frequency events." + ::= { acpmFreqEntry 2 } + --1.3.6.1.4.1.3052.10.2.12.12.4.1.2 + +acpmFreqDeadband OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Deadband (hysteresis) for frequency event. This is a floating point + value." + ::= { acpmFreqEntry 3 } + --1.3.6.1.4.1.3052.10.2.12.12.4.1.3 + +acpmFreqVHighValue OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Very high event threshold. This is a floating point value." + ::= { acpmFreqEntry 4 } + --1.3.6.1.4.1.3052.10.2.12.12.4.1.4 + +acpmFreqVHighActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Very high event actions." + ::= { acpmFreqEntry 5 } + --1.3.6.1.4.1.3052.10.2.12.12.4.1.5 + +acpmFreqVHighTrapNum OBJECT-TYPE + SYNTAX Integer32 (522..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Very high event trap number." + ::= { acpmFreqEntry 6 } + --1.3.6.1.4.1.3052.10.2.12.12.4.1.6 + +acpmFreqVHighClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Very high event class." + ::= { acpmFreqEntry 7 } + --1.3.6.1.4.1.3052.10.2.12.12.4.1.7 + +acpmFreqHighValue OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "High event threshold. This is a floating point value." + ::= { acpmFreqEntry 8 } + --1.3.6.1.4.1.3052.10.2.12.12.4.1.8 + +acpmFreqHighActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "High event actions." + ::= { acpmFreqEntry 9 } + --1.3.6.1.4.1.3052.10.2.12.12.4.1.9 + +acpmFreqHighTrapNum OBJECT-TYPE + SYNTAX Integer32 (522..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "High event trap number." + ::= { acpmFreqEntry 10 } + --1.3.6.1.4.1.3052.10.2.12.12.4.1.10 + +acpmFreqHighClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "High event class." + ::= { acpmFreqEntry 11 } + --1.3.6.1.4.1.3052.10.2.12.12.4.1.11 + +acpmFreqNormalActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Return to normal actions." + ::= { acpmFreqEntry 12 } + --1.3.6.1.4.1.3052.10.2.12.12.4.1.12 + +acpmFreqNormalTrapNum OBJECT-TYPE + SYNTAX Integer32 (522..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Return to normal trap number." + ::= { acpmFreqEntry 13 } + --1.3.6.1.4.1.3052.10.2.12.12.4.1.13 + +acpmFreqNormalClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Return to normal class." + ::= { acpmFreqEntry 14 } + --1.3.6.1.4.1.3052.10.2.12.12.4.1.14 + +acpmFreqLowValue OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Low event threshold. This is a floating point value." + ::= { acpmFreqEntry 15 } + --1.3.6.1.4.1.3052.10.2.12.12.4.1.15 + +acpmFreqLowActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Low event actions." + ::= { acpmFreqEntry 16 } + --1.3.6.1.4.1.3052.10.2.12.12.4.1.16 + +acpmFreqLowTrapNum OBJECT-TYPE + SYNTAX Integer32 (522..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Low event trap number." + ::= { acpmFreqEntry 17 } + --1.3.6.1.4.1.3052.10.2.12.12.4.1.17 + +acpmFreqLowClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Low event class." + ::= { acpmFreqEntry 18 } + --1.3.6.1.4.1.3052.10.2.12.12.4.1.18 + +acpmFreqVLowValue OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Very low event threshold. This is a floating point value." + ::= { acpmFreqEntry 19 } + --1.3.6.1.4.1.3052.10.2.12.12.4.1.19 + +acpmFreqVLowActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Very low event actions." + ::= { acpmFreqEntry 20 } + --1.3.6.1.4.1.3052.10.2.12.12.4.1.20 + +acpmFreqVLowTrapNum OBJECT-TYPE + SYNTAX Integer32 (522..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Very low event trap number." + ::= { acpmFreqEntry 21 } + --1.3.6.1.4.1.3052.10.2.12.12.4.1.21 + +acpmFreqVLowClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Very low event class." + ::= { acpmFreqEntry 22 } + --1.3.6.1.4.1.3052.10.2.12.12.4.1.22 + +acpmFreqSysrepEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "System reporting enable for frequency telemetry." + ::= { acpmFreqEntry 23 } + --1.3.6.1.4.1.3052.10.2.12.12.4.1.23 + +acpmFreqSysrepThreshold OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "System reporting threshold for frequency telemetry. This is a + floating point value." + ::= { acpmFreqEntry 24 } + --1.3.6.1.4.1.3052.10.2.12.12.4.1.24 + +acpmFreqSysrepLimit OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "System reporting limit for frequency telemetry." + ::= { acpmFreqEntry 25 } + --1.3.6.1.4.1.3052.10.2.12.12.4.1.25 + + +acpmTotalRealPowerTable OBJECT-TYPE + SYNTAX SEQUENCE OF ACPMConfigTRP + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table organizes AC power monitor total real power attributes." + ::= { acPowerMonitor 5 } + --1.3.6.1.4.1.3052.10.2.12.12.5 + +acpmTRPEntry OBJECT-TYPE + SYNTAX ACPMConfigTRP + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry for AC power monitor total real power config table." + INDEX { acpmTRPIndex } + ::= { acpmTotalRealPowerTable 1 } + --1.3.6.1.4.1.3052.10.2.12.12.5.1 + +acpmTRPIndex OBJECT-TYPE + SYNTAX Integer32 (1..6) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Which AC power monitor in the AC power monitor total real power + config table." + ::= { acpmTRPEntry 1 } + --1.3.6.1.4.1.3052.10.2.12.12.5.1.1 + +acpmTRPEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable AC power monitor total real power events." + ::= { acpmTRPEntry 2 } + --1.3.6.1.4.1.3052.10.2.12.12.5.1.2 + +acpmTRPDeadband OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Deadband (hysteresis) for total real power event. This is a + floating point value." + ::= { acpmTRPEntry 3 } + --1.3.6.1.4.1.3052.10.2.12.12.5.1.3 + +acpmTRPVHighValue OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Very high event threshold. This is a floating point value." + ::= { acpmTRPEntry 4 } + --1.3.6.1.4.1.3052.10.2.12.12.5.1.4 + +acpmTRPVHighActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Very high event actions." + ::= { acpmTRPEntry 5 } + --1.3.6.1.4.1.3052.10.2.12.12.5.1.5 + +acpmTRPVHighTrapNum OBJECT-TYPE + SYNTAX Integer32 (523..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Very high event trap number." + ::= { acpmTRPEntry 6 } + --1.3.6.1.4.1.3052.10.2.12.12.5.1.6 + +acpmTRPVHighClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Very high event class." + ::= { acpmTRPEntry 7 } + --1.3.6.1.4.1.3052.10.2.12.12.5.1.7 + +acpmTRPHighValue OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "High event threshold. This is a floating point value." + ::= { acpmTRPEntry 8 } + --1.3.6.1.4.1.3052.10.2.12.12.5.1.8 + +acpmTRPHighActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "High event actions." + ::= { acpmTRPEntry 9 } + --1.3.6.1.4.1.3052.10.2.12.12.5.1.9 + +acpmTRPHighTrapNum OBJECT-TYPE + SYNTAX Integer32 (523..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "High event trap number." + ::= { acpmTRPEntry 10 } + --1.3.6.1.4.1.3052.10.2.12.12.5.1.10 + +acpmTRPHighClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "High event class." + ::= { acpmTRPEntry 11 } + --1.3.6.1.4.1.3052.10.2.12.12.5.1.11 + +acpmTRPNormalActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Return to normal actions." + ::= { acpmTRPEntry 12 } + --1.3.6.1.4.1.3052.10.2.12.12.5.1.12 + +acpmTRPNormalTrapNum OBJECT-TYPE + SYNTAX Integer32 (523..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Return to normal trap number." + ::= { acpmTRPEntry 13 } + --1.3.6.1.4.1.3052.10.2.12.12.5.1.13 + +acpmTRPNormalClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Return to normal class." + ::= { acpmTRPEntry 14 } + --1.3.6.1.4.1.3052.10.2.12.12.5.1.14 + +acpmTRPLowValue OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Low event threshold. This is a floating point value." + ::= { acpmTRPEntry 15 } + --1.3.6.1.4.1.3052.10.2.12.12.5.1.15 + +acpmTRPLowActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Low event actions." + ::= { acpmTRPEntry 16 } + --1.3.6.1.4.1.3052.10.2.12.12.5.1.16 + +acpmTRPLowTrapNum OBJECT-TYPE + SYNTAX Integer32 (523..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Low event trap number." + ::= { acpmTRPEntry 17 } + --1.3.6.1.4.1.3052.10.2.12.12.5.1.17 + +acpmTRPLowClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Low event class." + ::= { acpmTRPEntry 18 } + --1.3.6.1.4.1.3052.10.2.12.12.5.1.18 + +acpmTRPVLowValue OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Very low event threshold. This is a floating point value." + ::= { acpmTRPEntry 19 } + --1.3.6.1.4.1.3052.10.2.12.12.5.1.19 + +acpmTRPVLowActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Very low event actions." + ::= { acpmTRPEntry 20 } + --1.3.6.1.4.1.3052.10.2.12.12.5.1.20 + +acpmTRPVLowTrapNum OBJECT-TYPE + SYNTAX Integer32 (523..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Very low event trap number." + ::= { acpmTRPEntry 21 } + --1.3.6.1.4.1.3052.10.2.12.12.5.1.21 + +acpmTRPVLowClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Very low event class." + ::= { acpmTRPEntry 22 } + --1.3.6.1.4.1.3052.10.2.12.12.5.1.22 + +acpmTRPSysrepEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "System reporting enable for total real power telemetry." + ::= { acpmTRPEntry 23 } + --1.3.6.1.4.1.3052.10.2.12.12.5.1.23 + +acpmTRPSysrepThreshold OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "System reporting threshold for total real power telemetry. This is a + floating point value." + ::= { acpmTRPEntry 24 } + --1.3.6.1.4.1.3052.10.2.12.12.5.1.24 + +acpmTRPSysrepLimit OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "System reporting limit for total real power telemetry." + ::= { acpmTRPEntry 25 } + --1.3.6.1.4.1.3052.10.2.12.12.5.1.25 + + +acpmDisconnectTable OBJECT-TYPE + SYNTAX SEQUENCE OF ACPMConfigDisconnect + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table organizes AC power monitor device disconnect event + attributes." + ::= { acPowerMonitor 6 } + --1.3.6.1.4.1.3052.10.2.12.12.6 + +acpmDisconnectEntry OBJECT-TYPE + SYNTAX ACPMConfigDisconnect + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry for AC power monitor device disconnect event config table." + INDEX { acpmDisconnectIndex } + ::= { acpmDisconnectTable 1 } + --1.3.6.1.4.1.3052.10.2.12.12.6.1 + +acpmDisconnectIndex OBJECT-TYPE + SYNTAX Integer32 (1..6) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Which AC power monitor in the AC power monitor device disconnect event + config table." + ::= { acpmDisconnectEntry 1 } + --1.3.6.1.4.1.3052.10.2.12.12.6.1.1 + +acpmDisconnectEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable AC power monitor device disconnect event." + ::= { acpmDisconnectEntry 2 } + --1.3.6.1.4.1.3052.10.2.12.12.6.1.2 + +acpmDisconnectActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Actions for disconnect event." + ::= { acpmDisconnectEntry 3 } + --1.3.6.1.4.1.3052.10.2.12.12.6.1.3 + +acpmDisconnectTrapNum OBJECT-TYPE + SYNTAX Integer32 (524..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Trap number for disconnect event." + ::= { acpmDisconnectEntry 4 } + --1.3.6.1.4.1.3052.10.2.12.12.6.1.4 + +acpmDisconnectClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Class for disconnect event." + ::= { acpmDisconnectEntry 5 } + --1.3.6.1.4.1.3052.10.2.12.12.6.1.5 + +acpmDisconnectNormalActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Actions for disconnect return to normal event." + ::= { acpmDisconnectEntry 6 } + --1.3.6.1.4.1.3052.10.2.12.12.6.1.6 + +acpmDisconnectNormalTrapNum OBJECT-TYPE + SYNTAX Integer32 (524..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Trap number for disconnect return to normal event." + ::= { acpmDisconnectEntry 7 } + --1.3.6.1.4.1.3052.10.2.12.12.6.1.7 + +acpmDisconnectNormalClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Class for disconnect return to normal event." + ::= { acpmDisconnectEntry 8 } + --1.3.6.1.4.1.3052.10.2.12.12.6.1.8 + +acpmTotalPowerFactorTable OBJECT-TYPE + SYNTAX SEQUENCE OF ACPMConfigTotalPowerFactor + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table organizes AC power monitor device total power factor + event attributes." + ::= { acPowerMonitor 7 } + --1.3.6.1.4.1.3052.10.2.12.12.7 + +acpmTPFEntry OBJECT-TYPE + SYNTAX ACPMConfigTotalPowerFactor + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry for AC power monitor device total power factor event config + table." + INDEX { acpmTPFIndex } + ::= { acpmTotalPowerFactorTable 1 } + --1.3.6.1.4.1.3052.10.2.12.12.7.1 + +acpmTPFIndex OBJECT-TYPE + SYNTAX Integer32 (1..6) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Which AC power monitor in the AC power monitor device disconnect + event config table." + ::= { acpmTPFEntry 1 } + --1.3.6.1.4.1.3052.10.2.12.12.7.1.1 + +acpmTPFEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable AC power monitor device disconnect event." + ::= { acpmTPFEntry 2 } + --1.3.6.1.4.1.3052.10.2.12.12.7.1.2 + +acpmTPFDeadband OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Deadband (hysteresis)." + ::= { acpmTPFEntry 3 } + --1.3.6.1.4.1.3052.10.2.12.12.7.1.3 + +acpmTPFNormalActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Normal actions." + ::= { acpmTPFEntry 4 } + --1.3.6.1.4.1.3052.10.2.12.12.7.1.4 + +acpmTPFNormalTrapNum OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Normal trap number." + ::= { acpmTPFEntry 5 } + --1.3.6.1.4.1.3052.10.2.12.12.7.1.5 + +acpmTPFNormalClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Normal class." + ::= { acpmTPFEntry 6 } + --1.3.6.1.4.1.3052.10.2.12.12.7.1.6 + +acpmTPFLowValue OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Low threshold." + ::= { acpmTPFEntry 7 } + --1.3.6.1.4.1.3052.10.2.12.12.7.1.7 + +acpmTPFLowActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Low actions." + ::= { acpmTPFEntry 8 } + --1.3.6.1.4.1.3052.10.2.12.12.7.1.8 + +acpmTPFLowTrapNum OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Low trap number." + ::= { acpmTPFEntry 9 } + --1.3.6.1.4.1.3052.10.2.12.12.7.1.9 + +acpmTPFLowClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Low class." + ::= { acpmTPFEntry 10 } + --1.3.6.1.4.1.3052.10.2.12.12.7.1.10 + +acpmTPFVLowValue OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Very Low threshold." + ::= { acpmTPFEntry 11 } + --1.3.6.1.4.1.3052.10.2.12.12.7.1.11 + +acpmTPFVLowActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Very Low actions." + ::= { acpmTPFEntry 12 } + --1.3.6.1.4.1.3052.10.2.12.12.7.1.12 + +acpmTPFVLowTrapNum OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Very Low trap number." + ::= { acpmTPFEntry 13 } + --1.3.6.1.4.1.3052.10.2.12.12.7.1.13 + +acpmTPFVLowClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Very Low class." + ::= { acpmTPFEntry 14 } + --1.3.6.1.4.1.3052.10.2.12.12.7.1.14 + +acpmTPFSysrepEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "System reporting enable." + ::= { acpmTPFEntry 15 } + --1.3.6.1.4.1.3052.10.2.12.12.7.1.15 + +acpmTPFSysrepThreshold OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "System reporting threshold." + ::= { acpmTPFEntry 16 } + --1.3.6.1.4.1.3052.10.2.12.12.7.1.16 + +acpmTPFSysrepLimit OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "System reporting limit." + ::= { acpmTPFEntry 17 } + --1.3.6.1.4.1.3052.10.2.12.12.7.1.17 + + + +--*************************************************************************************** +--Reset Event Section 2.12.16 +--*************************************************************************************** + + +evResetEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable/disable reset event. This event is triggered when the unit + finishes booting." + ::= { evReset 1 } + --1.3.6.1.4.1.3052.10.2.12.16.1 + +evResetDelay OBJECT-TYPE + SYNTAX Integer32 (0..3600) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Number of seconds to wait after unit finishes booting before triggering + the reset event." + ::= { evReset 2 } + --1.3.6.1.4.1.3052.10.2.12.16.2 + +evResetActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Actions for reset event." + ::= { evReset 3 } + --1.3.6.1.4.1.3052.10.2.12.16.3 + +evResetMessage OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Message for reset event." + ::= { evReset 4 } + --1.3.6.1.4.1.3052.10.2.12.16.4 + +evResetTrapnum OBJECT-TYPE + SYNTAX Integer32 (543..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Trap number for reset event." + ::= { evReset 5 } + --1.3.6.1.4.1.3052.10.2.12.16.5 + +evResetClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Class (severity) for reset event." + ::= { evReset 6 } + --1.3.6.1.4.1.3052.10.2.12.16.6 + + +--*************************************************************************************** +--Global Event Section 2.12.18 +--*************************************************************************************** + +evGlobalActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Global event actions." + ::= { evGlobal 2 } + --1.3.6.1.4.1.3052.10.2.12.18.2 + +evGlobalTrapnum OBJECT-TYPE + SYNTAX Integer32 (0..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Global trap number." + ::= { evGlobal 3 } + --1.3.6.1.4.1.3052.10.2.12.18.3 + + +--*************************************************************************************** +--HVAC Configuration Section 2.12.19 +--*************************************************************************************** +--*************************************************************************************** +--BARD HVAC Configuration Section 2.12.19.2 +--*************************************************************************************** + +evHVACBardIPAddress OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "IP address of the Bard HVAC controller." + ::= { evHVACBardLocal 1 } + --1.3.6.1.4.1.3052.10.2.12.19.2.1.1 + +evHVACBardPort OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "TCP port of the Bard HVAC controller interface." + ::= { evHVACBardLocal 2 } + --1.3.6.1.4.1.3052.10.2.12.19.2.1.2 + +evHVACBardTimeout OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Seconds to wait for a response from the Bard HVAC controller." + ::= { evHVACBardLocal 3 } + --1.3.6.1.4.1.3052.10.2.12.19.2.1.3 + +evHVACBardXMLStatus OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "XML status page of the Bard HVAC controller." + ::= { evHVACBardLocal 4 } + --1.3.6.1.4.1.3052.10.2.12.19.2.1.4 + +evHVACBardXMLSettings OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "XML settings page of the Bard HVAC controller." + ::= { evHVACBardLocal 5 } + --1.3.6.1.4.1.3052.10.2.12.19.2.1.5 + +evHVACBardWebSettingsHTML OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Web settings page of the Bard HVAC controller." + ::= { evHVACBardLocal 6 } + --1.3.6.1.4.1.3052.10.2.12.19.2.1.6 + +evHVACBardAlarmEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable/disable the Bard HVAC Alarm event." + ::= { evHVACBardAlarm 1 } + --1.3.6.1.4.1.3052.10.2.12.19.2.1.7.1 + +evHVACBardAlarmActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Actions for the Bard HVAC Alarm event." + ::= { evHVACBardAlarm 2 } + --1.3.6.1.4.1.3052.10.2.12.19.2.1.7.2 + +evHVACBardAlarmTrapnum OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Trap number for the Bard HVAC Alarm event." + ::= { evHVACBardAlarm 3 } + --1.3.6.1.4.1.3052.10.2.12.19.2.1.7.3 + +evHVACBardAlarmClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Class (severity) for the Bard HVAC Alarm event." + ::= { evHVACBardAlarm 4 } + --1.3.6.1.4.1.3052.10.2.12.19.2.1.7.4 + +evHVACBardAlarmNormalActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Actions for the Bard HVAC Alarm Return to Normal event." + ::= { evHVACBardAlarm 5 } + --1.3.6.1.4.1.3052.10.2.12.19.2.1.7.5 + +evHVACBardAlarmNormalTrapnum OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Trap number for the Bard HVAC Alarm Return to Normal event." + ::= { evHVACBardAlarm 6 } + --1.3.6.1.4.1.3052.10.2.12.19.2.1.7.6 + +evHVACBardAlarmNormalClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Class (severity) for the Bard HVAC Alarm Return to Normal event." + ::= { evHVACBardAlarm 7 } + --1.3.6.1.4.1.3052.10.2.12.19.2.1.7.7 + +evHVACBardReset OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Set to any value to reset the Bard HVAC controller. Always reads zero." + ::= { evHVACBardLocal 8 } + --1.3.6.1.4.1.3052.10.2.12.19.2.1.8 + +evHVACBardDefault OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Set to any value to restore default settings on the Bard HVAC controller. Always reads zero." + ::= { evHVACBardLocal 9 } + --1.3.6.1.4.1.3052.10.2.12.19.2.1.9 + +evHVACBardTempScale OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Scale used, Celsius or Fahrenheit (C or F)." + ::= { evHVACBardSynchronized 1 } + --1.3.6.1.4.1.3052.10.2.12.19.2.2.1 + +evHVACBardCoolThreshold OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Cooling threshold to turn on HVAC cooling elements (economizer/compressor)." + ::= { evHVACBardSynchronized 2 } + --1.3.6.1.4.1.3052.10.2.12.19.2.2.2 + +evHVACBardCoolThresholdState OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Synchronization status of previous object: ERROR (with possible description), PENDING, or OK." + ::= { evHVACBardSynchronized 3 } + --1.3.6.1.4.1.3052.10.2.12.19.2.2.3 + +evHVACBardHeatThreshold OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Heating threshold to turn on HVAC heating elements (economizer/compressor)." + ::= { evHVACBardSynchronized 4 } + --1.3.6.1.4.1.3052.10.2.12.19.2.2.4 + +evHVACBardHeatDiff OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Heating differential to turn on HVAC heating elements. The heating threshold + is calculated by subtracting this number from the current cool threshold." + ::= { evHVACBardSynchronized 5 } + --1.3.6.1.4.1.3052.10.2.12.19.2.2.5 + +evHVACBardHeatDiffState OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Synchronization status of previous object: ERROR (with possible description), PENDING, or OK." + ::= { evHVACBardSynchronized 6 } + --1.3.6.1.4.1.3052.10.2.12.19.2.2.6 + +evHVACBardBlower OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Continuous blower operation enable." + ::= { evHVACBardSynchronized 7 } + --1.3.6.1.4.1.3052.10.2.12.19.2.2.7 + +evHVACBardBlowerState OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Synchronization status of previous object: ERROR (with possible description), PENDING, or OK." + ::= { evHVACBardSynchronized 8 } + --1.3.6.1.4.1.3052.10.2.12.19.2.2.8 + +evHVACBardAlternate OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Alternate lead-lag sequence for the economizer." + ::= { evHVACBardSynchronized 9 } + --1.3.6.1.4.1.3052.10.2.12.19.2.2.9 + +evHVACBardAlternateState OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Synchronization status of previous object: ERROR (with possible description), PENDING, or OK." + ::= { evHVACBardSynchronized 10 } + --1.3.6.1.4.1.3052.10.2.12.19.2.2.10 + +evHVACBardChangeover OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Lead-lag changeover time in days." + ::= { evHVACBardSynchronized 11 } + --1.3.6.1.4.1.3052.10.2.12.19.2.2.11 + +evHVACBardChangeoverState OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Synchronization status of previous object: ERROR (with possible description), PENDING, or OK." + ::= { evHVACBardSynchronized 12 } + --1.3.6.1.4.1.3052.10.2.12.19.2.2.12 + +evHVACBardBlowDiff OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable to run blowers if two sensors have a difference of 5 F or greater." + ::= { evHVACBardSynchronized 13 } + --1.3.6.1.4.1.3052.10.2.12.19.2.2.13 + +evHVACBardBlowDiffState OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Synchronization status of previous object: ERROR (with possible description), PENDING, or OK." + ::= { evHVACBardSynchronized 14 } + --1.3.6.1.4.1.3052.10.2.12.19.2.2.14 + +evHVACBardOffDelay OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "3 minute lead/4 minute lag unit off delay enable." + ::= { evHVACBardSynchronized 15 } + --1.3.6.1.4.1.3052.10.2.12.19.2.2.15 + +evHVACBardOffDelayState OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Synchronization status of previous object: ERROR (with possible description), PENDING, or OK." + ::= { evHVACBardSynchronized 16 } + --1.3.6.1.4.1.3052.10.2.12.19.2.2.16 + +evHVACBardRunMin OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Run the compressor for at least 3 minutes before shutting off enable." + ::= { evHVACBardSynchronized 17 } + --1.3.6.1.4.1.3052.10.2.12.19.2.2.17 + +evHVACBardRunMinState OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Synchronization status of previous object: ERROR (with possible description), PENDING, or OK." + ::= { evHVACBardSynchronized 18 } + --1.3.6.1.4.1.3052.10.2.12.19.2.2.18 + +evHVACBardStage1Diff OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Temperature differential between stages 1 and 2." + ::= { evHVACBardDiff 1 } + --1.3.6.1.4.1.3052.10.2.12.19.2.2.19.1 + +evHVACBardStage1DiffState OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Synchronization status of previous object: ERROR (with possible description), PENDING, or OK." + ::= { evHVACBardDiff 2 } + --1.3.6.1.4.1.3052.10.2.12.19.2.2.19.2 + +evHVACBardStage2Diff OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Temperature differential between stages 2 and 3." + ::= { evHVACBardDiff 3 } + --1.3.6.1.4.1.3052.10.2.12.19.2.2.19.3 + +evHVACBardStage2DiffState OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Synchronization status of previous object: ERROR (with possible description), PENDING, or OK." + ::= { evHVACBardDiff 4 } + --1.3.6.1.4.1.3052.10.2.12.19.2.2.19.4 + +evHVACBardStage3Diff OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Temperature differential between stages 3 and 4." + ::= { evHVACBardDiff 5 } + --1.3.6.1.4.1.3052.10.2.12.19.2.2.19.5 + +evHVACBardStage3DiffState OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Synchronization status of previous object: ERROR (with possible description), PENDING, or OK." + ::= { evHVACBardDiff 6 } + --1.3.6.1.4.1.3052.10.2.12.19.2.2.19.6 + +evHVACBardCoolDisableDb OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Cooling disable deadband." + ::= { evHVACBardSynchronized 20 } + --1.3.6.1.4.1.3052.10.2.12.19.2.2.20 + +evHVACBardCoolDisableDbState OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Synchronization status of previous object: ERROR (with possible description), PENDING, or OK." + ::= { evHVACBardSynchronized 21 } + --1.3.6.1.4.1.3052.10.2.12.19.2.2.21 + +evHVACBardCoolEnableDb OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Cooling enable deadband." + ::= { evHVACBardSynchronized 22 } + --1.3.6.1.4.1.3052.10.2.12.19.2.2.22 + +evHVACBardCoolEnableDbState OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Synchronization status of previous object: ERROR (with possible description), PENDING, or OK." + ::= { evHVACBardSynchronized 23 } + --1.3.6.1.4.1.3052.10.2.12.19.2.2.23 + +evHVACBardHeatDb OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Heating deadband." + ::= { evHVACBardSynchronized 24 } + --1.3.6.1.4.1.3052.10.2.12.19.2.2.24 + +evHVACBardHeatDbState OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Synchronization status of previous object: ERROR (with possible description), PENDING, or OK." + ::= { evHVACBardSynchronized 25 } + --1.3.6.1.4.1.3052.10.2.12.19.2.2.25 + +evHVACBardHeatPump OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Heat pump logic enable." + ::= { evHVACBardSynchronized 26 } + --1.3.6.1.4.1.3052.10.2.12.19.2.2.26 + +evHVACBardHeatPumpState OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Synchronization status of previous object: ERROR (with possible description), PENDING, or OK." + ::= { evHVACBardSynchronized 27 } + --1.3.6.1.4.1.3052.10.2.12.19.2.2.27 + +evHVACBardCompressors OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Synchronization status of previous object: ERROR (with possible description), PENDING, or OK." + ::= { evHVACBardSynchronized 28 } + --1.3.6.1.4.1.3052.10.2.12.19.2.2.28 + +evHVACBardCompressorsState OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Synchronization status of previous object: ERROR (with possible description), PENDING, or OK." + ::= { evHVACBardSynchronized 29 } + --1.3.6.1.4.1.3052.10.2.12.19.2.2.29 + +evHVACBardEconomizer OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Synchronization status of previous object: ERROR (with possible description), PENDING, or OK." + ::= { evHVACBardSynchronized 30 } + --1.3.6.1.4.1.3052.10.2.12.19.2.2.30 + +evHVACBardEconomizerState OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Synchronization status of previous object: ERROR (with possible description), PENDING, or OK." + ::= { evHVACBardSynchronized 31 } + --1.3.6.1.4.1.3052.10.2.12.19.2.2.31 + +evHVACBardTempLowValue OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Low alarm for temperature." + ::= { evHVACBardTemp 1 } + --1.3.6.1.4.1.3052.10.2.12.19.2.2.32.1 + +evHVACBardTempLowValueState OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Synchronization status of previous object: ERROR (with possible description), PENDING, or OK." + ::= { evHVACBardTemp 2 } + --1.3.6.1.4.1.3052.10.2.12.19.2.2.32.2 + +evHVACBardTempHighValue OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "High alarm for temperature." + ::= { evHVACBardTemp 3 } + --1.3.6.1.4.1.3052.10.2.12.19.2.2.32.3 + +evHVACBardTempHighValueState OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Synchronization status of previous object: ERROR (with possible description), PENDING, or OK." + ::= { evHVACBardTemp 4 } + --1.3.6.1.4.1.3052.10.2.12.19.2.2.32.4 + +evHVACBardTempVHighValue OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Very high alarm for temperature." + ::= { evHVACBardTemp 5 } + --1.3.6.1.4.1.3052.10.2.12.19.2.2.32.5 + +evHVACBardTempVHighValueState OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Synchronization status of previous object: ERROR (with possible description), PENDING, or OK." + ::= { evHVACBardTemp 6 } + --1.3.6.1.4.1.3052.10.2.12.19.2.2.32.6 + +evHVACBardOverride OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The HVAC controller override." + ::= { evHVACBardSynchronized 33 } + --1.3.6.1.4.1.3052.10.2.12.19.2.2.33 + +evHVACBardOverrideState OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Synchronization status of previous object: ERROR (with possible description), PENDING, or OK." + ::= { evHVACBardSynchronized 34 } + --1.3.6.1.4.1.3052.10.2.12.19.2.2.34 + +evHVACBardLock OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable the external controller lock." + ::= { evHVACBardSynchronized 35 } + --1.3.6.1.4.1.3052.10.2.12.19.2.2.35 + +evHVACBardLockState OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Synchronization status of previous object: ERROR (with possible description), PENDING, or OK." + ::= { evHVACBardSynchronized 36 } + --1.3.6.1.4.1.3052.10.2.12.19.2.2.36 + +evHVACBardLeadUnit OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Which HVAC unit is currently the lead unit." + ::= { evHVACBardSynchronized 37 } + --1.3.6.1.4.1.3052.10.2.12.19.2.2.37 + +evHVACBardLeadUnitState OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Synchronization status of previous object: ERROR (with possible description), PENDING, or OK." + ::= { evHVACBardSynchronized 38 } + --1.3.6.1.4.1.3052.10.2.12.19.2.2.38 + +evHVACBardComfort OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable comfort mode." + ::= { evHVACBardSynchronized 39 } + --1.3.6.1.4.1.3052.10.2.12.19.2.2.39 + +evHVACBardComfortState OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Synchronization status of previous object: ERROR (with possible description), PENDING, or OK." + ::= { evHVACBardSynchronized 40 } + --1.3.6.1.4.1.3052.10.2.12.19.2.2.40 + + +--*************************************************************************************** +--Asentria HVAC Configuration Section 2.12.19.3 +--*************************************************************************************** + +evHVACAsentriaSensorListTable OBJECT-TYPE + SYNTAX SEQUENCE OF HVACAsentriaSensorList + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Asentria HVAC temperature/humidity sensor list table" + ::= { evHVACAsentria 1 } + --1.3.6.1.4.1.3052.10.2.12.19.3.1 + +evHVACAsentriaSensorListEntry OBJECT-TYPE + SYNTAX HVACAsentriaSensorList + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Asentria HVAC temperature/humidity sensor list table entry" + INDEX { evHVACAsentriaSensorListIndex } + ::= { evHVACAsentriaSensorListTable 1 } + --1.3.6.1.4.1.3052.10.2.12.19.3.1.1 + +evHVACAsentriaSensorListIndex OBJECT-TYPE + SYNTAX Integer32 (1..12) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Index for Asentria HVAC temperature/humidity sensor" + ::= { evHVACAsentriaSensorListEntry 1 } + --1.3.6.1.4.1.3052.10.2.12.19.3.1.1.1 + +evHVACAsentriaSensorListES OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC temperature/humidity sensor EventSensor number" + ::= { evHVACAsentriaSensorListEntry 2 } + --1.3.6.1.4.1.3052.10.2.12.19.3.1.1.2 + +evHVACAsentriaSensorListPT OBJECT-TYPE + SYNTAX Integer32 (1..64) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC temperature/humidity sensor point" + ::= { evHVACAsentriaSensorListEntry 3 } + --1.3.6.1.4.1.3052.10.2.12.19.3.1.1.3 + +evHVACAsentriaSensorListType OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC temperature/humidity sensor type" + ::= { evHVACAsentriaSensorListEntry 4 } + --1.3.6.1.4.1.3052.10.2.12.19.3.1.1.4 + +evHVACAsentriaSensorListLoc OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC temperature/humidity sensor location" + ::= { evHVACAsentriaSensorListEntry 5 } + --1.3.6.1.4.1.3052.10.2.12.19.3.1.1.5 + +evHVACAsentriaOverride OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC controller override" + ::= { evHVACAsentria 2 } + --1.3.6.1.4.1.3052.10.2.12.19.3.2 + +evHVACAsentriaSchedule OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC unit primary/lead swap schedule" + ::= { evHVACAsentria 3 } + --1.3.6.1.4.1.3052.10.2.12.19.3.3 + +evHVACAsentriaPrimary OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC primary/lead unit to operate" + ::= { evHVACAsentria 4 } + --1.3.6.1.4.1.3052.10.2.12.19.3.4 + +evHVACAsentriaMethod OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC controller temperature/humidity calculation + method" + ::= { evHVACAsentria 5 } + --1.3.6.1.4.1.3052.10.2.12.19.3.5 + +evHVACAsentriaAlarmLagNormEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC enable for normal/idle alarm notification on + lag unit" + ::= { evHVACAsentriaAlarm 1 } + --1.3.6.1.4.1.3052.10.2.12.19.3.6.1 + +evHVACAsentriaAlarmLagNormActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC actions to perform for normal/idle alarm + notification on lag unit" + ::= { evHVACAsentriaAlarm 2 } + --1.3.6.1.4.1.3052.10.2.12.19.3.6.2 + +evHVACAsentriaAlarmLagNormTrapNum OBJECT-TYPE + SYNTAX Integer32 (545..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC trap number for normal/idle alarm notification + on lag unit" + ::= { evHVACAsentriaAlarm 3 } + --1.3.6.1.4.1.3052.10.2.12.19.3.6.3 + +evHVACAsentriaAlarmLagNormClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC alarm class for normal/idle alarm notification + on lag unit" + ::= { evHVACAsentriaAlarm 4 } + --1.3.6.1.4.1.3052.10.2.12.19.3.6.4 + +evHVACAsentriaAlarmLagVentEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC enable for venting alarm notification on lag + unit" + ::= { evHVACAsentriaAlarm 5 } + --1.3.6.1.4.1.3052.10.2.12.19.3.6.5 + +evHVACAsentriaAlarmLagVentActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC actions to perform for venting alarm + notification on lag unit" + ::= { evHVACAsentriaAlarm 6 } + --1.3.6.1.4.1.3052.10.2.12.19.3.6.6 + +evHVACAsentriaAlarmLagVentTrapNum OBJECT-TYPE + SYNTAX Integer32 (545..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC trap number for venting alarm notification on + lag unit" + ::= { evHVACAsentriaAlarm 7 } + --1.3.6.1.4.1.3052.10.2.12.19.3.6.7 + +evHVACAsentriaAlarmLagVentClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC alarm class for venting alarm notification on + lag unit" + ::= { evHVACAsentriaAlarm 8 } + --1.3.6.1.4.1.3052.10.2.12.19.3.6.8 + +evHVACAsentriaAlarmLagCoolEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC enable for cooling alarm notification on lag + unit" + ::= { evHVACAsentriaAlarm 9 } + --1.3.6.1.4.1.3052.10.2.12.19.3.6.9 + +evHVACAsentriaAlarmLagCoolActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC actions to perform for cooling alarm + notification on lag unit" + ::= { evHVACAsentriaAlarm 10 } + --1.3.6.1.4.1.3052.10.2.12.19.3.6.10 + +evHVACAsentriaAlarmLagCoolTrapNum OBJECT-TYPE + SYNTAX Integer32 (545..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC trap number for cooling alarm notification on + lag unit" + ::= { evHVACAsentriaAlarm 11 } + --1.3.6.1.4.1.3052.10.2.12.19.3.6.11 + +evHVACAsentriaAlarmLagCoolClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC alarm class for cooling alarm notification on + lag unit" + ::= { evHVACAsentriaAlarm 12 } + --1.3.6.1.4.1.3052.10.2.12.19.3.6.12 + +evHVACAsentriaAlarmLagHeatEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC enable for heating alarm notification on lag + unit" + ::= { evHVACAsentriaAlarm 13 } + --1.3.6.1.4.1.3052.10.2.12.19.3.6.13 + +evHVACAsentriaAlarmLagHeatActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC actions to perform for heating alarm + notification on lag unit" + ::= { evHVACAsentriaAlarm 14 } + --1.3.6.1.4.1.3052.10.2.12.19.3.6.14 + +evHVACAsentriaAlarmLagHeatTrapNum OBJECT-TYPE + SYNTAX Integer32 (545..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC trap number for heating alarm notification on + lag unit" + ::= { evHVACAsentriaAlarm 15 } + --1.3.6.1.4.1.3052.10.2.12.19.3.6.15 + +evHVACAsentriaAlarmLagHeatClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC alarm class for heating alarm notification on + lag unit" + ::= { evHVACAsentriaAlarm 16 } + --1.3.6.1.4.1.3052.10.2.12.19.3.6.16 + +evHVACAsentriaFireES OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC fire/smoke alarm EventSensor number" + ::= { evHVACAsentriaFire 1 } + --1.3.6.1.4.1.3052.10.2.12.19.3.7.1 + +evHVACAsentriaFirePT OBJECT-TYPE + SYNTAX Integer32 (1..64) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC fire/smoke alarm point number" + ::= { evHVACAsentriaFire 2 } + --1.3.6.1.4.1.3052.10.2.12.19.3.7.2 + +evHVACAsentriaFireActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC actions to perform for fire/smoke alarm + notification" + ::= { evHVACAsentriaFire 3 } + --1.3.6.1.4.1.3052.10.2.12.19.3.7.3 + +evHVACAsentriaFireTrapnum OBJECT-TYPE + SYNTAX Integer32 (545..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC trap number for fire/smoke alarm notification" + ::= { evHVACAsentriaFire 4 } + --1.3.6.1.4.1.3052.10.2.12.19.3.7.4 + +evHVACAsentriaFireClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC alarm class for fire/smoke alarm notification" + ::= { evHVACAsentriaFire 5 } + --1.3.6.1.4.1.3052.10.2.12.19.3.7.5 + +evHVACAsentriaFireNormActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC return to normal actions to perform for + fire/smoke alarm notification" + ::= { evHVACAsentriaFire 6 } + --1.3.6.1.4.1.3052.10.2.12.19.3.7.6 + +evHVACAsentriaFireNormTrapNum OBJECT-TYPE + SYNTAX Integer32 (545..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC return to normal trap number for fire/smoke + alarm notification" + ::= { evHVACAsentriaFire 7 } + --1.3.6.1.4.1.3052.10.2.12.19.3.7.7 + +evHVACAsentriaFireNormClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC return to normal class for fire/smoke alarm + notification" + ::= { evHVACAsentriaFire 8 } + --1.3.6.1.4.1.3052.10.2.12.19.3.7.8 + +evHVACAsentriaUnitTable OBJECT-TYPE + SYNTAX SEQUENCE OF HVACAsentriaUnit + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Asentria HVAC unit table" + ::= { evHVACAsentria 8 } + --1.3.6.1.4.1.3052.10.2.12.19.3.8 + +evHVACAsentriaUnitEntry OBJECT-TYPE + SYNTAX HVACAsentriaUnit + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Asentria HVAC unit table entry" + INDEX { evHVACAsentriaUnitIndex } + ::= { evHVACAsentriaUnitTable 1 } + --1.3.6.1.4.1.3052.10.2.12.19.3.8.1 + +evHVACAsentriaUnitIndex OBJECT-TYPE + SYNTAX Integer32 (1..2) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Index for Asentria HVAC unit" + ::= { evHVACAsentriaUnitEntry 1 } + --1.3.6.1.4.1.3052.10.2.12.19.3.8.1.1 + +evHVACAsentriaUnitEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC unit enable" + ::= { evHVACAsentriaUnitEntry 2 } + --1.3.6.1.4.1.3052.10.2.12.19.3.8.1.2 + +evHVACAsentriaUnitFanRelayES OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "EventSensor number of relay to control the fan on Asentria + HVAC controller" + ::= { evHVACAsentriaUnitEntry 3 } + --1.3.6.1.4.1.3052.10.2.12.19.3.8.1.3 + +evHVACAsentriaUnitFanRelayPT OBJECT-TYPE + SYNTAX Integer32 (1..16) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Point number of relay to control the fan on Asentria HVAC + controller" + ::= { evHVACAsentriaUnitEntry 4 } + --1.3.6.1.4.1.3052.10.2.12.19.3.8.1.4 + +evHVACAsentriaUnitVentRelayES OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "EventSensor number of relay to control the vent on Asentria + HVAC controller" + ::= { evHVACAsentriaUnitEntry 5 } + --1.3.6.1.4.1.3052.10.2.12.19.3.8.1.5 + +evHVACAsentriaUnitVentRelayPT OBJECT-TYPE + SYNTAX Integer32 (1..16) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Point number of relay to control the vent on Asentria HVAC + controller" + ::= { evHVACAsentriaUnitEntry 6 } + --1.3.6.1.4.1.3052.10.2.12.19.3.8.1.6 + +evHVACAsentriaUnitTimereset OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Resets the time counter for Asentria HVAC unit" + ::= { evHVACAsentriaUnitEntry 7 } + --1.3.6.1.4.1.3052.10.2.12.19.3.8.1.7 + +evHVACAsentriaSeqTimereset OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Resets the time counter for Asentria HVAC sequence number" + ::= { evHVACAsentriaUnitEntry 8 } + --1.3.6.1.4.1.3052.10.2.12.19.3.8.1.8 + +evHVACAsentriaUnitStage1CoolES OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "EventSensor number of relay to control compressor stage 1 on + Asentria HVAC controller" + ::= { evHVACAsentriaUnitEntry 20 } + --1.3.6.1.4.1.3052.10.2.12.19.3.8.1.20 + +evHVACAsentriaUnitStage1CoolPT OBJECT-TYPE + SYNTAX Integer32 (1..16) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Point number of relay to control compressor stage 1 on + Asentria HVAC controller" + ::= { evHVACAsentriaUnitEntry 21 } + --1.3.6.1.4.1.3052.10.2.12.19.3.8.1.21 + +evHVACAsentriaUnitStage1HeatES OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "EventSensor number of relay to control heater stage 1 on + Asentria HVAC controller" + ::= { evHVACAsentriaUnitEntry 22 } + --1.3.6.1.4.1.3052.10.2.12.19.3.8.1.22 + +evHVACAsentriaUnitStage1HeatPT OBJECT-TYPE + SYNTAX Integer32 (1..16) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Point number of relay to control heater stage 1 on + Asentria HVAC controller" + ::= { evHVACAsentriaUnitEntry 23 } + --1.3.6.1.4.1.3052.10.2.12.19.3.8.1.23 + +evHVACAsentriaUnitStage2CoolES OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "EventSensor number of relay to control compressor stage 2 on + Asentria HVAC controller" + ::= { evHVACAsentriaUnitEntry 30 } + --1.3.6.1.4.1.3052.10.2.12.19.3.8.1.30 + +evHVACAsentriaUnitStage2CoolPT OBJECT-TYPE + SYNTAX Integer32 (1..16) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Point number of relay to control compressor stage 2 on + Asentria HVAC controller" + ::= { evHVACAsentriaUnitEntry 31 } + --1.3.6.1.4.1.3052.10.2.12.19.3.8.1.31 + +evHVACAsentriaUnitStage2HeatES OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "EventSensor number of relay to control heater stage 2 on + Asentria HVAC controller" + ::= { evHVACAsentriaUnitEntry 32 } + --1.3.6.1.4.1.3052.10.2.12.19.3.8.1.32 + +evHVACAsentriaUnitStage2HeatPT OBJECT-TYPE + SYNTAX Integer32 (1..16) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Point number of relay to control heater stage 2 on + Asentria HVAC controller" + ::= { evHVACAsentriaUnitEntry 33 } + --1.3.6.1.4.1.3052.10.2.12.19.3.8.1.33 + +evHVACAsentriaTempScale OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC controller temperature scale" + ::= { evHVACAsentriaTemp 1 } + --1.3.6.1.4.1.3052.10.2.12.19.3.9.1 + +evHVACAsentriaTempCoolThresh OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Temperature above this threshold before cooling via Asentria + HVAC controller" + ::= { evHVACAsentriaTemp 2 } + --1.3.6.1.4.1.3052.10.2.12.19.3.9.2 + +evHVACAsentriaTempHeatThresh OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Temperature below this threshold before heating via Asentria + HVAC controller" + ::= { evHVACAsentriaTemp 3 } + --1.3.6.1.4.1.3052.10.2.12.19.3.9.3 + +evHVACAsentriaTempEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC temperature alarm enable" + ::= { evHVACAsentriaTemp 4 } + --1.3.6.1.4.1.3052.10.2.12.19.3.9.4 + +evHVACAsentriaTempEventDeadband OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC temperature alarm event deadband" + ::= { evHVACAsentriaTemp 5 } + --1.3.6.1.4.1.3052.10.2.12.19.3.9.5 + +evHVACAsentriaTempVLowValue OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC temperature alarm event very low value" + ::= { evHVACAsentriaTemp 6 } + --1.3.6.1.4.1.3052.10.2.12.19.3.9.6 + +evHVACAsentriaTempVLowActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC temperature alarm event very low actions" + ::= { evHVACAsentriaTemp 7 } + --1.3.6.1.4.1.3052.10.2.12.19.3.9.7 + +evHVACAsentriaTempVLowTrapNum OBJECT-TYPE + SYNTAX Integer32 (545..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC temperature alarm event very low trap number" + ::= { evHVACAsentriaTemp 8 } + --1.3.6.1.4.1.3052.10.2.12.19.3.9.8 + +evHVACAsentriaTempVLowClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC temperature alarm event very low class" + ::= { evHVACAsentriaTemp 9 } + --1.3.6.1.4.1.3052.10.2.12.19.3.9.9 + +evHVACAsentriaTempLowValue OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC temperature alarm event low value" + ::= { evHVACAsentriaTemp 10 } + --1.3.6.1.4.1.3052.10.2.12.19.3.9.10 + +evHVACAsentriaTempLowActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC temperature alarm event low actions" + ::= { evHVACAsentriaTemp 11 } + --1.3.6.1.4.1.3052.10.2.12.19.3.9.11 + +evHVACAsentriaTempLowTrapNum OBJECT-TYPE + SYNTAX Integer32 (545..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC temperature alarm event low trap number" + ::= { evHVACAsentriaTemp 12 } + --1.3.6.1.4.1.3052.10.2.12.19.3.9.12 + +evHVACAsentriaTempLowClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC temperature alarm event low class" + ::= { evHVACAsentriaTemp 13 } + --1.3.6.1.4.1.3052.10.2.12.19.3.9.13 + +evHVACAsentriaTempNormalActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC temperature alarm event return to normal + actions" + ::= { evHVACAsentriaTemp 14 } + --1.3.6.1.4.1.3052.10.2.12.19.3.9.14 + +evHVACAsentriaTempNormalTrapNum OBJECT-TYPE + SYNTAX Integer32 (545..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC temperature alarm event return to normal trap + number" + ::= { evHVACAsentriaTemp 15 } + --1.3.6.1.4.1.3052.10.2.12.19.3.9.15 + +evHVACAsentriaTempNormalClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC temperature alarm event return to normal class" + ::= { evHVACAsentriaTemp 16 } + --1.3.6.1.4.1.3052.10.2.12.19.3.9.16 + +evHVACAsentriaTempHighValue OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC temperature alarm event high value" + ::= { evHVACAsentriaTemp 17 } + --1.3.6.1.4.1.3052.10.2.12.19.3.9.17 + +evHVACAsentriaTempHighActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC temperature alarm event high actions" + ::= { evHVACAsentriaTemp 18 } + --1.3.6.1.4.1.3052.10.2.12.19.3.9.18 + +evHVACAsentriaTempHighTrapNum OBJECT-TYPE + SYNTAX Integer32 (545..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC temperature alarm event high trap number" + ::= { evHVACAsentriaTemp 19 } + --1.3.6.1.4.1.3052.10.2.12.19.3.9.19 + +evHVACAsentriaTempHighClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC temperature alarm event high class" + ::= { evHVACAsentriaTemp 20 } + --1.3.6.1.4.1.3052.10.2.12.19.3.9.20 + +evHVACAsentriaTempVHighValue OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC temperature alarm event very high value" + ::= { evHVACAsentriaTemp 21 } + --1.3.6.1.4.1.3052.10.2.12.19.3.9.21 + +evHVACAsentriaTempVHighActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC temperature alarm event very high actions" + ::= { evHVACAsentriaTemp 22 } + --1.3.6.1.4.1.3052.10.2.12.19.3.9.22 + +evHVACAsentriaTempVHighTrapNum OBJECT-TYPE + SYNTAX Integer32 (545..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC temperature alarm event very high trap number" + ::= { evHVACAsentriaTemp 23 } + --1.3.6.1.4.1.3052.10.2.12.19.3.9.23 + +evHVACAsentriaTempVHighClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC temperature alarm event very high class" + ::= { evHVACAsentriaTemp 24 } + --1.3.6.1.4.1.3052.10.2.12.19.3.9.24 + +evHVACAsentriaTempDeadband OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC temperature deadband before stopping current + state" + ::= { evHVACAsentriaTemp 25 } + --1.3.6.1.4.1.3052.10.2.12.19.3.9.25 + +evHVACAsentriaTempDifference OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC temperature step before changing states" + ::= { evHVACAsentriaTemp 26 } + --1.3.6.1.4.1.3052.10.2.12.19.3.9.26 + +evHVACAsentriaHumidInThresh OBJECT-TYPE + SYNTAX Integer32 (0..100) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Humidity above this threshold before cooling via Asentria + HVAC controller" + ::= { evHVACAsentriaHumid 2 } + --1.3.6.1.4.1.3052.10.2.12.19.3.9.2 + +evHVACAsentriaHumidOutThresh OBJECT-TYPE + SYNTAX Integer32 (0..100) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Humidity above this threshold before not allowing venting via + Asentria HVAC controller" + ::= { evHVACAsentriaHumid 3 } + --1.3.6.1.4.1.3052.10.2.12.19.3.9.3 + +evHVACAsentriaHumidEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC humidity alarm enable" + ::= { evHVACAsentriaHumid 4 } + --1.3.6.1.4.1.3052.10.2.12.19.3.9.4 + +evHVACAsentriaHumidEventDeadband OBJECT-TYPE + SYNTAX Integer32 (1..100) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC humidity alarm event deadband" + ::= { evHVACAsentriaHumid 5 } + --1.3.6.1.4.1.3052.10.2.12.19.3.9.5 + +evHVACAsentriaHumidVLowValue OBJECT-TYPE + SYNTAX Integer32 (0..100) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC humidity alarm event very low value" + ::= { evHVACAsentriaHumid 6 } + --1.3.6.1.4.1.3052.10.2.12.19.3.9.6 + +evHVACAsentriaHumidVLowActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC humidity alarm event very low actions" + ::= { evHVACAsentriaHumid 7 } + --1.3.6.1.4.1.3052.10.2.12.19.3.9.7 + +evHVACAsentriaHumidVLowTrapNum OBJECT-TYPE + SYNTAX Integer32 (545..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC humidity alarm event very low trap number" + ::= { evHVACAsentriaHumid 8 } + --1.3.6.1.4.1.3052.10.2.12.19.3.9.8 + +evHVACAsentriaHumidVLowClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC humidity alarm event very low class" + ::= { evHVACAsentriaHumid 9 } + --1.3.6.1.4.1.3052.10.2.12.19.3.9.9 + +evHVACAsentriaHumidLowValue OBJECT-TYPE + SYNTAX Integer32 (0..100) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC humidity alarm event low value" + ::= { evHVACAsentriaHumid 10 } + --1.3.6.1.4.1.3052.10.2.12.19.3.9.10 + +evHVACAsentriaHumidLowActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC humidity alarm event low actions" + ::= { evHVACAsentriaHumid 11 } + --1.3.6.1.4.1.3052.10.2.12.19.3.9.11 + +evHVACAsentriaHumidLowTrapNum OBJECT-TYPE + SYNTAX Integer32 (545..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC humidity alarm event low trap number" + ::= { evHVACAsentriaHumid 12 } + --1.3.6.1.4.1.3052.10.2.12.19.3.9.12 + +evHVACAsentriaHumidLowClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC humidity alarm event low class" + ::= { evHVACAsentriaHumid 13 } + --1.3.6.1.4.1.3052.10.2.12.19.3.9.13 + +evHVACAsentriaHumidNormalActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC humidity alarm event return to normal + actions" + ::= { evHVACAsentriaHumid 14 } + --1.3.6.1.4.1.3052.10.2.12.19.3.9.14 + +evHVACAsentriaHumidNormalTrapNum OBJECT-TYPE + SYNTAX Integer32 (545..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC humidity alarm event return to normal trap + number" + ::= { evHVACAsentriaHumid 15 } + --1.3.6.1.4.1.3052.10.2.12.19.3.9.15 + +evHVACAsentriaHumidNormalClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC humidity alarm event return to normal class" + ::= { evHVACAsentriaHumid 16 } + --1.3.6.1.4.1.3052.10.2.12.19.3.9.16 + +evHVACAsentriaHumidHighValue OBJECT-TYPE + SYNTAX Integer32 (0..100) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC humidity alarm event high value" + ::= { evHVACAsentriaHumid 17 } + --1.3.6.1.4.1.3052.10.2.12.19.3.9.17 + +evHVACAsentriaHumidHighActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC humidity alarm event high actions" + ::= { evHVACAsentriaHumid 18 } + --1.3.6.1.4.1.3052.10.2.12.19.3.9.18 + +evHVACAsentriaHumidHighTrapNum OBJECT-TYPE + SYNTAX Integer32 (545..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC humidity alarm event high trap number" + ::= { evHVACAsentriaHumid 19 } + --1.3.6.1.4.1.3052.10.2.12.19.3.9.19 + +evHVACAsentriaHumidHighClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC humidity alarm event high class" + ::= { evHVACAsentriaHumid 20 } + --1.3.6.1.4.1.3052.10.2.12.19.3.9.20 + +evHVACAsentriaHumidVHighValue OBJECT-TYPE + SYNTAX Integer32 (0..100) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC humidity alarm event very high value" + ::= { evHVACAsentriaHumid 21 } + --1.3.6.1.4.1.3052.10.2.12.19.3.9.21 + +evHVACAsentriaHumidVHighActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC humidity alarm event very high actions" + ::= { evHVACAsentriaHumid 22 } + --1.3.6.1.4.1.3052.10.2.12.19.3.9.22 + +evHVACAsentriaHumidVHighTrapNum OBJECT-TYPE + SYNTAX Integer32 (545..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC humidity alarm event very high trap number" + ::= { evHVACAsentriaHumid 23 } + --1.3.6.1.4.1.3052.10.2.12.19.3.9.23 + +evHVACAsentriaHumidVHighClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC humidity alarm event very high class" + ::= { evHVACAsentriaHumid 24 } + --1.3.6.1.4.1.3052.10.2.12.19.3.9.24 + +evHVACAsentriaHumidDeadband OBJECT-TYPE + SYNTAX Integer32 (1..10) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC humidity deadband before stopping current + state" + ::= { evHVACAsentriaHumid 25 } + --1.3.6.1.4.1.3052.10.2.12.19.3.9.25 + +evHVACAsentriaHumidDifference OBJECT-TYPE + SYNTAX Integer32 (1..10) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Asentria HVAC humidity step before changing states" + ::= { evHVACAsentriaHumid 26 } + --1.3.6.1.4.1.3052.10.2.12.19.3.9.26 + + +--*************************************************************************************** +--Airsys HVAC Configuration Section 2.12.19.4 +--*************************************************************************************** + +evHVACAirsysGeneratorLogic OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC generator logic" + ::= { evHVACAirsysGeneral 1 } + --1.3.6.1.4.1.3052.10.2.12.19.4.1.1 + +evHVACAirsysFreeMode OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC free mode" + ::= { evHVACAirsysGeneral 2 } + --1.3.6.1.4.1.3052.10.2.12.19.4.1.2 + +evHVACAirsysRemoteEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC remote control enable" + ::= { evHVACAirsysGeneral 3 } + --1.3.6.1.4.1.3052.10.2.12.19.4.1.3 + +evHVACAirsysHVACRotation OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC rotate unit lead/lag" + ::= { evHVACAirsysGeneral 4 } + --1.3.6.1.4.1.3052.10.2.12.19.4.1.4 + +evHVACAirsysRotationRuntime OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC rotation runtime period" + ::= { evHVACAirsysGeneral 5 } + --1.3.6.1.4.1.3052.10.2.12.19.4.1.5 + +evHVACAirsysUnitTable OBJECT-TYPE + SYNTAX SEQUENCE OF HVACAirsysUnit + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Airsys HVAC unit table" + ::= { evHVACAirsysAlarm 1 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.1 + +evHVACAirsysUnitEntry OBJECT-TYPE + SYNTAX HVACAirsysUnit + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Airsys HVAC unit table entry" + INDEX { evHVACAirsysUnitIndex } + ::= { evHVACAirsysUnitTable 1 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1 + +evHVACAirsysUnitIndex OBJECT-TYPE + SYNTAX Integer32 (1..2) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Index for Airsys HVAC unit" + ::= { evHVACAirsysUnitEntry 1 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.1 + +evHVACAirsysULowPEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC unit low pressure alarm enable" + ::= { evHVACAirsysUnitEntry 2 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.2 + +evHVACAirsysULowPActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC actions to perform for low pressure alarm + notification" + ::= { evHVACAirsysUnitEntry 3 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.3 + +evHVACAirsysULowPTrapnum OBJECT-TYPE + SYNTAX Integer32 (548..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC trap number for low pressure alarm notification" + ::= { evHVACAirsysUnitEntry 4 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.4 + +evHVACAirsysULowPClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC alarm class for low pressure alarm notification" + ::= { evHVACAirsysUnitEntry 5 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.5 + +evHVACAirsysULowPNormActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC return to normal actions to perform for + low pressure alarm notification" + ::= { evHVACAirsysUnitEntry 6 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.6 + +evHVACAirsysULowPNormTrapNum OBJECT-TYPE + SYNTAX Integer32 (548..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC return to normal trap number for low pressure + alarm notification" + ::= { evHVACAirsysUnitEntry 7 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.7 + +evHVACAirsysULowPNormClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC return to normal class for low pressure alarm + notification" + ::= { evHVACAirsysUnitEntry 8 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.8 + +evHVACAirsysUHighPEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC unit high pressure alarm enable" + ::= { evHVACAirsysUnitEntry 9 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.9 + +evHVACAirsysUHighPActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC actions to perform for high pressure alarm + notification" + ::= { evHVACAirsysUnitEntry 10 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.10 + +evHVACAirsysUHighPTrapnum OBJECT-TYPE + SYNTAX Integer32 (548..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC trap number for high pressure alarm notification" + ::= { evHVACAirsysUnitEntry 11 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.11 + +evHVACAirsysUHighPClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC alarm class for high pressure alarm notification" + ::= { evHVACAirsysUnitEntry 12 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.12 + +evHVACAirsysUHighPNormActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC return to normal actions to perform for + high pressure alarm notification" + ::= { evHVACAirsysUnitEntry 13 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.13 + +evHVACAirsysUHighPNormTrapNum OBJECT-TYPE + SYNTAX Integer32 (548..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC return to normal trap number for high pressure + alarm notification" + ::= { evHVACAirsysUnitEntry 14 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.14 + +evHVACAirsysUHighPNormClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC return to normal class for high pressure alarm + notification" + ::= { evHVACAirsysUnitEntry 15 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.15 + +evHVACAirsysUEvapFanEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC unit evaporator fan alarm enable" + ::= { evHVACAirsysUnitEntry 16 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.16 + +evHVACAirsysUEvapFanActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC actions to perform for evaporator fan alarm + notification" + ::= { evHVACAirsysUnitEntry 17 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.17 + +evHVACAirsysUEvapFanTrapnum OBJECT-TYPE + SYNTAX Integer32 (548..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC trap number for evaporator fan alarm notification" + ::= { evHVACAirsysUnitEntry 18 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.18 + +evHVACAirsysUEvapFanClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC alarm class for evaporator fan alarm notification" + ::= { evHVACAirsysUnitEntry 19 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.19 + +evHVACAirsysUEvapFanNormActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC return to normal actions to perform for + evaporator fan alarm notification" + ::= { evHVACAirsysUnitEntry 20 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.20 + +evHVACAirsysUEvapFanNormTrapNum OBJECT-TYPE + SYNTAX Integer32 (548..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC return to normal trap number for evaporator fan + alarm notification" + ::= { evHVACAirsysUnitEntry 21 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.21 + +evHVACAirsysUEvapFanNormClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC return to normal class for evaporator fan alarm + notification" + ::= { evHVACAirsysUnitEntry 22 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.22 + +evHVACAirsysUDirtyEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC unit dirty filter alarm enable" + ::= { evHVACAirsysUnitEntry 23 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.23 + +evHVACAirsysUDirtyActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC actions to perform for dirty filter alarm + notification" + ::= { evHVACAirsysUnitEntry 24 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.24 + +evHVACAirsysUDirtyTrapnum OBJECT-TYPE + SYNTAX Integer32 (548..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC trap number for dirty filter alarm notification" + ::= { evHVACAirsysUnitEntry 25 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.25 + +evHVACAirsysUDirtyClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC alarm class for dirty filter alarm notification" + ::= { evHVACAirsysUnitEntry 26 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.26 + +evHVACAirsysUDirtyNormActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC return to normal actions to perform for + dirty filter alarm notification" + ::= { evHVACAirsysUnitEntry 27 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.27 + +evHVACAirsysUDirtyNormTrapNum OBJECT-TYPE + SYNTAX Integer32 (548..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC return to normal trap number for dirty filter + alarm notification" + ::= { evHVACAirsysUnitEntry 28 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.28 + +evHVACAirsysUDirtyNormClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC return to normal class for dirty filter alarm + notification" + ::= { evHVACAirsysUnitEntry 29 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.29 + +evHVACAirsysUInProbeEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC unit indoor probe broken alarm enable" + ::= { evHVACAirsysUnitEntry 30 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.30 + +evHVACAirsysUInProbeActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC actions to perform for indoor probe broken + alarm notification" + ::= { evHVACAirsysUnitEntry 31 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.31 + +evHVACAirsysUInProbeTrapnum OBJECT-TYPE + SYNTAX Integer32 (548..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC trap number for indoor probe broken alarm + notification" + ::= { evHVACAirsysUnitEntry 32 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.32 + +evHVACAirsysUInProbeClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC alarm class for indoor probe broken alarm + notification" + ::= { evHVACAirsysUnitEntry 33 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.33 + +evHVACAirsysUInProbeNormActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC return to normal actions to perform for + indoor probe broken alarm notification" + ::= { evHVACAirsysUnitEntry 34 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.34 + +evHVACAirsysUInProbeNormTrapNum OBJECT-TYPE + SYNTAX Integer32 (548..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC return to normal trap number for indoor probe + broken alarm notification" + ::= { evHVACAirsysUnitEntry 35 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.35 + +evHVACAirsysUInProbeNormClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC return to normal class for indoor probe broken + alarm notification" + ::= { evHVACAirsysUnitEntry 36 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.36 + +evHVACAirsysUDamperEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC unit high pressure alarm enable" + ::= { evHVACAirsysUnitEntry 37 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.37 + +evHVACAirsysUDamperActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC actions to perform for high pressure alarm + notification" + ::= { evHVACAirsysUnitEntry 38 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.38 + +evHVACAirsysUDamperTrapnum OBJECT-TYPE + SYNTAX Integer32 (548..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC trap number for high pressure alarm notification" + ::= { evHVACAirsysUnitEntry 39 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.39 + +evHVACAirsysUDamperClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC alarm class for high pressure alarm notification" + ::= { evHVACAirsysUnitEntry 40 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.40 + +evHVACAirsysUDamperNormActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC return to normal actions to perform for + high pressure alarm notification" + ::= { evHVACAirsysUnitEntry 41 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.41 + +evHVACAirsysUDamperNormTrapNum OBJECT-TYPE + SYNTAX Integer32 (548..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC return to normal trap number for high pressure + alarm notification" + ::= { evHVACAirsysUnitEntry 42 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.42 + +evHVACAirsysUDamperNormClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC return to normal class for high pressure alarm + notification" + ::= { evHVACAirsysUnitEntry 43 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.43 + +evHVACAirsysUSupProbeEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC unit supply probe broken alarm enable" + ::= { evHVACAirsysUnitEntry 44 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.44 + +evHVACAirsysUSupProbeActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC actions to perform for supply probe broken + alarm notification" + ::= { evHVACAirsysUnitEntry 45 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.45 + +evHVACAirsysUSupProbeTrapnum OBJECT-TYPE + SYNTAX Integer32 (548..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC trap number for supply probe broken alarm + notification" + ::= { evHVACAirsysUnitEntry 46 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.46 + +evHVACAirsysUSupProbeClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC alarm class for supply probe broken alarm + notification" + ::= { evHVACAirsysUnitEntry 47 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.47 + +evHVACAirsysUSupProbeNormActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC return to normal actions to perform for + supply probe broken alarm notification" + ::= { evHVACAirsysUnitEntry 48 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.48 + +evHVACAirsysUSupProbeNormTrapNum OBJECT-TYPE + SYNTAX Integer32 (548..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC return to normal trap number for supply probe + broken alarm notification" + ::= { evHVACAirsysUnitEntry 49 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.49 + +evHVACAirsysUSupProbeNormClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC return to normal class for supply probe broken + alarm notification" + ::= { evHVACAirsysUnitEntry 50 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.50 + +evHVACAirsysSmokeFireEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC unit smoke/fire alarm enable" + ::= { evHVACAirsysAlarm 2 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.2 + +evHVACAirsysSmokeFireActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC actions to perform for smoke/fire alarm + notification" + ::= { evHVACAirsysAlarm 3 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.3 + +evHVACAirsysSmokeFireTrapnum OBJECT-TYPE + SYNTAX Integer32 (548..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC trap number for smoke/fire alarm notification" + ::= { evHVACAirsysAlarm 4 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.4 + +evHVACAirsysSmokeFireClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC alarm class for smoke/fire alarm notification" + ::= { evHVACAirsysAlarm 5 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.5 + +evHVACAirsysSmokeFireNormActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC return to normal actions to perform for + smoke/fire alarm notification" + ::= { evHVACAirsysAlarm 6 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.6 + +evHVACAirsysSmokeFireNormTrapNum OBJECT-TYPE + SYNTAX Integer32 (548..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC return to normal trap number for smoke/fire + alarm notification" + ::= { evHVACAirsysAlarm 7 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.7 + +evHVACAirsysSmokeFireNormClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC return to normal class for smoke/fire alarm + notification" + ::= { evHVACAirsysAlarm 8 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.8 + +evHVACAirsysLowRoomTempEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC unit low room temperature alarm enable" + ::= { evHVACAirsysAlarm 9 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.9 + +evHVACAirsysLowRoomTempActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC actions to perform for low room temperature + alarm notification" + ::= { evHVACAirsysAlarm 10 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.10 + +evHVACAirsysLowRoomTempTrapnum OBJECT-TYPE + SYNTAX Integer32 (548..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC trap number for low room temperature alarm + notification" + ::= { evHVACAirsysAlarm 11 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.11 + +evHVACAirsysLowRoomTempClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC alarm class for low room temperature alarm + notification" + ::= { evHVACAirsysAlarm 12 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.12 + +evHVACAirsysLowRoomTempNormActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC return to normal actions to perform for low + room temperature alarm notification" + ::= { evHVACAirsysAlarm 13 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.13 + +evHVACAirsysLowRoomTempNormTrapNum OBJECT-TYPE + SYNTAX Integer32 (548..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC return to normal trap number for low room + temperature alarm notification" + ::= { evHVACAirsysAlarm 14 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.14 + +evHVACAirsysLowRoomTempNormClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC return to normal class for low room temperature + alarm notification" + ::= { evHVACAirsysAlarm 15 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.15 + +evHVACAirsysHighRoomTempEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC unit high room temperature alarm enable" + ::= { evHVACAirsysAlarm 16 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.16 + +evHVACAirsysHighRoomTempActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC actions to perform for high room temperature + alarm notification" + ::= { evHVACAirsysAlarm 17 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.17 + +evHVACAirsysHighRoomTempTrapnum OBJECT-TYPE + SYNTAX Integer32 (548..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC trap number for high room temperature alarm + notification" + ::= { evHVACAirsysAlarm 18 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.18 + +evHVACAirsysHighRoomTempClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC alarm class for high room temperature alarm + notification" + ::= { evHVACAirsysAlarm 19 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.19 + +evHVACAirsysHighRoomTempNormActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC return to normal actions to perform for high + room temperature alarm notification" + ::= { evHVACAirsysAlarm 20 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.20 + +evHVACAirsysHighRoomTempNormTrapNum OBJECT-TYPE + SYNTAX Integer32 (548..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC return to normal trap number for high room + temperature alarm notification" + ::= { evHVACAirsysAlarm 21 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.21 + +evHVACAirsysHighRoomTempNormClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC return to normal class for high room + temperature alarm notification" + ::= { evHVACAirsysAlarm 22 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.22 + +evHVACAirsysPowerEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC unit power failure alarm enable" + ::= { evHVACAirsysAlarm 23 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.23 + +evHVACAirsysPowerActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC actions to perform for power failure alarm + notification" + ::= { evHVACAirsysAlarm 24 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.24 + +evHVACAirsysPowerTrapnum OBJECT-TYPE + SYNTAX Integer32 (548..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC trap number for power failure alarm + notification" + ::= { evHVACAirsysAlarm 25 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.25 + +evHVACAirsysPowerClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC alarm class for power failure alarm + notification" + ::= { evHVACAirsysAlarm 26 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.26 + +evHVACAirsysPowerNormActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC return to normal actions to perform for power + failure alarm notification" + ::= { evHVACAirsysAlarm 27 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.27 + +evHVACAirsysPowerNormTrapNum OBJECT-TYPE + SYNTAX Integer32 (548..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC return to normal trap number for power failure + alarm notification" + ::= { evHVACAirsysAlarm 28 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.28 + +evHVACAirsysPowerNormClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC return to normal class for power failure alarm + notification" + ::= { evHVACAirsysAlarm 29 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.29 + +evHVACAirsyspLANEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC unit pLAN alarm enable" + ::= { evHVACAirsysAlarm 30 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.30 + +evHVACAirsyspLANActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC actions to perform for pLAN + alarm notification" + ::= { evHVACAirsysAlarm 31 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.31 + +evHVACAirsyspLANTrapnum OBJECT-TYPE + SYNTAX Integer32 (548..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC trap number for pLAN alarm notification" + ::= { evHVACAirsysAlarm 32 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.32 + +evHVACAirsyspLANClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC alarm class for pLAN alarm notification" + ::= { evHVACAirsysAlarm 33 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.33 + +evHVACAirsyspLANNormActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC return to normal actions to perform for pLAN + alarm notification" + ::= { evHVACAirsysAlarm 34 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.34 + +evHVACAirsyspLANNormTrapNum OBJECT-TYPE + SYNTAX Integer32 (548..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC return to normal trap number for pLAN alarm + notification" + ::= { evHVACAirsysAlarm 35 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.35 + +evHVACAirsyspLANNormClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC return to normal class for pLAN alarm + notification" + ::= { evHVACAirsysAlarm 36 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.36 + +evHVACAirsysClockEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC unit clock alarm enable" + ::= { evHVACAirsysAlarm 37 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.37 + +evHVACAirsysClockActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC actions to perform for clock alarm notification" + ::= { evHVACAirsysAlarm 38 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.38 + +evHVACAirsysClockTrapnum OBJECT-TYPE + SYNTAX Integer32 (548..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC trap number for clock alarm notification" + ::= { evHVACAirsysAlarm 39 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.39 + +evHVACAirsysClockClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC alarm class for clock alarm notification" + ::= { evHVACAirsysAlarm 40 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.40 + +evHVACAirsysClockNormActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC return to normal actions to perform for clock + alarm notification" + ::= { evHVACAirsysAlarm 41 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.41 + +evHVACAirsysClockNormTrapNum OBJECT-TYPE + SYNTAX Integer32 (548..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC return to normal trap number for clock alarm + notification" + ::= { evHVACAirsysAlarm 42 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.42 + +evHVACAirsysClockNormClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC return to normal class for clock alarm + notification" + ::= { evHVACAirsysAlarm 43 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.43 + +evHVACAirsysHumidProbeEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC unit humidity probe broken alarm enable" + ::= { evHVACAirsysAlarm 44 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.44 + +evHVACAirsysHumidProbeActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC actions to perform for humidity probe broken + alarm notification" + ::= { evHVACAirsysAlarm 45 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.45 + +evHVACAirsysHumidProbeTrapnum OBJECT-TYPE + SYNTAX Integer32 (548..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC trap number for humidity probe broken alarm + notification" + ::= { evHVACAirsysAlarm 46 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.46 + +evHVACAirsysHumidProbeClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC alarm class for humidity probe broken alarm + notification" + ::= { evHVACAirsysAlarm 47 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.47 + +evHVACAirsysHumidProbeNormActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC return to normal actions to perform for + humidity probe broken alarm notification" + ::= { evHVACAirsysAlarm 48 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.48 + +evHVACAirsysHumidProbeNormTrapNum OBJECT-TYPE + SYNTAX Integer32 (548..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC return to normal trap number for humidity probe + broken alarm notification" + ::= { evHVACAirsysAlarm 49 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.49 + +evHVACAirsysHumidProbeNormClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC return to normal class for humidity probe broken + alarm notification" + ::= { evHVACAirsysAlarm 50 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.50 + +evHVACAirsysOutProbeEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC unit outdoor probe broken alarm enable" + ::= { evHVACAirsysAlarm 51 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.51 + +evHVACAirsysOutProbeActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC actions to perform for outdoor probe broken + alarm notification" + ::= { evHVACAirsysAlarm 52 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.52 + +evHVACAirsysOutProbeTrapnum OBJECT-TYPE + SYNTAX Integer32 (548..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC trap number for outdoor probe broken alarm + notification" + ::= { evHVACAirsysAlarm 53 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.53 + +evHVACAirsysOutProbeClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC alarm class for outdoor probe broken alarm + notification" + ::= { evHVACAirsysAlarm 54 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.54 + +evHVACAirsysOutProbeNormActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC return to normal actions to perform for + outdoor probe broken alarm notification" + ::= { evHVACAirsysAlarm 55 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.55 + +evHVACAirsysOutProbeNormTrapNum OBJECT-TYPE + SYNTAX Integer32 (548..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC return to normal trap number for outdoor probe + broken alarm notification" + ::= { evHVACAirsysAlarm 56 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.56 + +evHVACAirsysOutProbeNormClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC return to normal class for outdoor probe broken + alarm notification" + ::= { evHVACAirsysAlarm 57 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.57 + +evHVACAirsysBothCompressEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC unit both compressors on alarm enable" + ::= { evHVACAirsysAlarm 58 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.58 + +evHVACAirsysBothCompressActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC actions to perform for both compressors on + alarm notification" + ::= { evHVACAirsysAlarm 59 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.59 + +evHVACAirsysBothCompressTrapnum OBJECT-TYPE + SYNTAX Integer32 (548..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC trap number for both compressors on alarm + notification" + ::= { evHVACAirsysAlarm 60 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.60 + +evHVACAirsysBothCompressClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC alarm class for both compressors on alarm + notification" + ::= { evHVACAirsysAlarm 61 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.61 + +evHVACAirsysBothCompressNormActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC return to normal actions to perform for + both compressors on alarm notification" + ::= { evHVACAirsysAlarm 62 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.62 + +evHVACAirsysBothCompressNormTrapNum OBJECT-TYPE + SYNTAX Integer32 (548..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC return to normal trap number for both + compressors on alarm notification" + ::= { evHVACAirsysAlarm 63 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.63 + +evHVACAirsysBothCompressNormClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC return to normal class for both compressors on + alarm notification" + ::= { evHVACAirsysAlarm 64 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.64 + +evHVACAirsysGeneratorEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC unit generator running alarm enable" + ::= { evHVACAirsysAlarm 65 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.65 + +evHVACAirsysGeneratorActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC actions to perform for generator running + alarm notification" + ::= { evHVACAirsysAlarm 66 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.66 + +evHVACAirsysGeneratorTrapnum OBJECT-TYPE + SYNTAX Integer32 (548..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC trap number for generator running alarm + notification" + ::= { evHVACAirsysAlarm 67 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.67 + +evHVACAirsysGeneratorClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC alarm class for generator running alarm + notification" + ::= { evHVACAirsysAlarm 68 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.68 + +evHVACAirsysGeneratorNormActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC return to normal actions to perform for + generator running alarm notification" + ::= { evHVACAirsysAlarm 69 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.69 + +evHVACAirsysGeneratorNormTrapNum OBJECT-TYPE + SYNTAX Integer32 (548..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC return to normal trap number for generator + running alarm notification" + ::= { evHVACAirsysAlarm 70 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.70 + +evHVACAirsysGeneratorNormClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC return to normal class for generator running + alarm notification" + ::= { evHVACAirsysAlarm 71 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.71 + +evHVACAirsysConnectionEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC unit lost connection alarm enable" + ::= { evHVACAirsysAlarm 72 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.72 + +evHVACAirsysConnectionActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC actions to perform for lost connection + alarm notification" + ::= { evHVACAirsysAlarm 73 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.73 + +evHVACAirsysConnectionTrapnum OBJECT-TYPE + SYNTAX Integer32 (548..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC trap number for lost connection alarm + notification" + ::= { evHVACAirsysAlarm 74 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.74 + +evHVACAirsysConnectionClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC alarm class for lost connection alarm + notification" + ::= { evHVACAirsysAlarm 75 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.75 + +evHVACAirsysConnectionNormActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC return to normal actions to perform for + lost connection alarm notification" + ::= { evHVACAirsysAlarm 76 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.76 + +evHVACAirsysConnectionNormTrapNum OBJECT-TYPE + SYNTAX Integer32 (548..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC return to normal trap number for lost + connection alarm notification" + ::= { evHVACAirsysAlarm 77 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.77 + +evHVACAirsysConnectionNormClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC return to normal class for lost connection + alarm notification" + ::= { evHVACAirsysAlarm 78 } + --1.3.6.1.4.1.3052.10.2.12.19.4.2.78 + +evHVACAirsysTempBaseThresh OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC temperature base threshold" + ::= { evHVACAirsysTemp 1 } + --1.3.6.1.4.1.3052.10.2.12.19.4.3.1 + +evHVACAirsysTempCoolDeadband OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC temperature cool deadband" + ::= { evHVACAirsysTemp 2 } + --1.3.6.1.4.1.3052.10.2.12.19.4.3.2 + +evHVACAirsysTempHeatDeadband OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC temperature heat deadband" + ::= { evHVACAirsysTemp 3 } + --1.3.6.1.4.1.3052.10.2.12.19.4.3.3 + +evHVACAirsysTempHighValue OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC high temperature alarm value" + ::= { evHVACAirsysTemp 4 } + --1.3.6.1.4.1.3052.10.2.12.19.4.3.4 + +evHVACAirsysTempLowValue OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC low temperature alarm value" + ::= { evHVACAirsysTemp 5 } + --1.3.6.1.4.1.3052.10.2.12.19.4.3.5 + +evHVACAirsysHumidMaxFree OBJECT-TYPE + SYNTAX Integer32 (0..99) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC return to normal class for lost connection + alarm notification" + ::= { evHVACAirsysHumid 1 } + --1.3.6.1.4.1.3052.10.2.12.19.4.4.1 + +evHVACAirsysHumidDeadband OBJECT-TYPE + SYNTAX Integer32 (0..99) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Airsys HVAC return to normal class for lost connection + alarm notification" + ::= { evHVACAirsysHumid 2 } + --1.3.6.1.4.1.3052.10.2.12.19.4.4.2 + + +--*************************************************************************************** +--EVPS Section 2.12.20 +--*************************************************************************************** + +evpsEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "EVPS (Emerson Vortex Power System) enable." + ::= { evEvps 1 } + --1.3.6.1.4.1.3052.10.2.12.20.1 + +evpsIPAddress OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "EVPS IP address." + ::= { evEvps 2 } + --1.3.6.1.4.1.3052.10.2.12.20.2 + +evpsPort OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "EVPS IP web port." + ::= { evEvps 3 } + --1.3.6.1.4.1.3052.10.2.12.20.3 + +evpsTimeout OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "EVPS IP timeout." + ::= { evEvps 4 } + --1.3.6.1.4.1.3052.10.2.12.20.4 + + +--*************************************************************************************** +--Access Control Device Management Section 2.12.21 +--*************************************************************************************** + +acActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Actions for the access control event." + ::= { accessControl 2 } + --1.3.6.1.4.1.3052.10.2.12.21.2 + +acTrapnum OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Trap number for the access control event." + ::= { accessControl 3 } + --1.3.6.1.4.1.3052.10.2.12.21.3 + +acClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Class (severity) for the access control event." + ::= { accessControl 4 } + --1.3.6.1.4.1.3052.10.2.12.21.4 + +accessControlDeviceTable OBJECT-TYPE + SYNTAX SEQUENCE OF AccessControlDevice + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table of access control devices for Access Control Device Management." + ::= { accessControl 10 } + --1.3.6.1.4.1.3052.10.2.12.21.10 + +accessControlDeviceEntry OBJECT-TYPE + SYNTAX AccessControlDevice + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry for table of access control devices for Access Control Device Management." + INDEX { acdIndex } + ::= { accessControlDeviceTable 1 } + --1.3.6.1.4.1.3052.10.2.12.21.10.1 + +acdIndex OBJECT-TYPE + SYNTAX Integer32 (1..3) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Index for table of access control devices for Access Control Device Management." + ::= { accessControlDeviceEntry 1 } + --1.3.6.1.4.1.3052.10.2.12.21.10.1.1 + +acdEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable management for this access control device." + ::= { accessControlDeviceEntry 2 } + --1.3.6.1.4.1.3052.10.2.12.21.10.1.2 + +acdName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The name of the access control device for informational purpose only." + ::= { accessControlDeviceEntry 3 } + --1.3.6.1.4.1.3052.10.2.12.21.10.1.3 + +acdReader OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The kind of access control device." + ::= { accessControlDeviceEntry 4 } + --1.3.6.1.4.1.3052.10.2.12.21.10.1.4 + +acdWiegandES OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Index of the Wiegand interface hardware instance allocated as the access control device." + ::= { accessControlDeviceEntry 5 } + --1.3.6.1.4.1.3052.10.2.12.21.10.1.5 + +acdWiegandPoint OBJECT-TYPE + SYNTAX Integer32 (1..2) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Which wiegand on the wiegand EventSensor to use for as the access control device." + ::= { accessControlDeviceEntry 6 } + --1.3.6.1.4.1.3052.10.2.12.21.10.1.6 + +acdRelayType OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Type of relay which activates the door strike." + ::= { accessControlDeviceEntry 7 } + --1.3.6.1.4.1.3052.10.2.12.21.10.1.7 + +acdRelayES OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Which relay EventSensor is connected to the door strike." + ::= { accessControlDeviceEntry 8 } + --1.3.6.1.4.1.3052.10.2.12.21.10.1.8 + +acdRelayPoint OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Which relay on the relay EventSensor is connected to the door strike." + ::= { accessControlDeviceEntry 9 } + --1.3.6.1.4.1.3052.10.2.12.21.10.1.9 + +acdOpenTime OBJECT-TYPE + SYNTAX Integer32 (1..25) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "" + ::= { accessControlDeviceEntry 10 } + --1.3.6.1.4.1.3052.10.2.12.21.10.1.10 + +acdUserGroup OBJECT-TYPE + SYNTAX Integer32 (1..2) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "User group to which this access control device applies." + ::= { accessControlDeviceEntry 11 } + --1.3.6.1.4.1.3052.10.2.12.21.10.1.11 + +accessControlUserTable OBJECT-TYPE + SYNTAX SEQUENCE OF AccessControlUser + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table of access control users for Access Control Device Management." + ::= { accessControl 11 } + --1.3.6.1.4.1.3052.10.2.12.21.11 + +accessControlUserEntry OBJECT-TYPE + SYNTAX AccessControlUser + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry for table of access control users for Access Control Device Management." + INDEX { acuIndexUserGroup, acuIndexUser } + ::= { accessControlUserTable 1 } + --1.3.6.1.4.1.3052.10.2.12.21.11.1 + +acuIndexUserGroup OBJECT-TYPE + SYNTAX Integer32 (1..2) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Index for table of access control devices for Access Control Device Management + which corresponds to the user group containing the user." + ::= { accessControlUserEntry 1 } + --1.3.6.1.4.1.3052.10.2.12.21.10.1.1 + +acuIndexUser OBJECT-TYPE + SYNTAX Integer32 (1..50) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Index for table of access control devices for Access Control Device Management + which corresponds to the user within the user group." + ::= { accessControlUserEntry 2 } + --1.3.6.1.4.1.3052.10.2.12.21.10.1.2 + +acuEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable this access control user." + ::= { accessControlUserEntry 3 } + --1.3.6.1.4.1.3052.10.2.12.21.10.1.3 + +acuName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Name for this access control user." + ::= { accessControlUserEntry 4 } + --1.3.6.1.4.1.3052.10.2.12.21.10.1.4 + +acuSn OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Serial number of the card associated with the user." + ::= { accessControlUserEntry 5 } + --1.3.6.1.4.1.3052.10.2.12.21.10.1.5 + +acuSunBegin OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Time of day (HH:MM) on Sundays when this user should be granted access." + ::= { accessControlUserEntry 6 } + --1.3.6.1.4.1.3052.10.2.12.21.10.1.6 + +acuSunEnd OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Time of day (HH:MM) on Sundays when this user should be forbidden access." + ::= { accessControlUserEntry 7 } + --1.3.6.1.4.1.3052.10.2.12.21.10.1.7 + +acuMonBegin OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Time of day (HH:MM) on Mondays when this user should be granted access." + ::= { accessControlUserEntry 8 } + --1.3.6.1.4.1.3052.10.2.12.21.10.1.8 + +acuMonEnd OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Time of day (HH:MM) on Mondays when this user should be forbidden access." + ::= { accessControlUserEntry 9 } + --1.3.6.1.4.1.3052.10.2.12.21.10.1.9 + +acuTueBegin OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Time of day (HH:MM) on Tuesdays when this user should be granted access." + ::= { accessControlUserEntry 10 } + --1.3.6.1.4.1.3052.10.2.12.21.10.1.10 + +acuTueEnd OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Time of day (HH:MM) on Tuesdays when this user should be forbidden access." + ::= { accessControlUserEntry 11 } + --1.3.6.1.4.1.3052.10.2.12.21.10.1.11 + +acuWedBegin OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Time of day (HH:MM) on Wednesdays when this user should be granted access." + ::= { accessControlUserEntry 12 } + --1.3.6.1.4.1.3052.10.2.12.21.10.1.12 + +acuWedEnd OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Time of day (HH:MM) on Wednesdays when this user should be forbidden access." + ::= { accessControlUserEntry 13 } + --1.3.6.1.4.1.3052.10.2.12.21.10.1.13 + +acuThuBegin OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Time of day (HH:MM) on Thursdays when this user should be granted access." + ::= { accessControlUserEntry 14 } + --1.3.6.1.4.1.3052.10.2.12.21.10.1.14 + +acuThuEnd OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Time of day (HH:MM) on Thursdays when this user should be forbidden access." + ::= { accessControlUserEntry 15 } + --1.3.6.1.4.1.3052.10.2.12.21.10.1.15 + +acuFriBegin OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Time of day (HH:MM) on Fridays when this user should be granted access." + ::= { accessControlUserEntry 16 } + --1.3.6.1.4.1.3052.10.2.12.21.10.1.16 + +acuFriEnd OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Time of day (HH:MM) on Fridays when this user should be forbidden access." + ::= { accessControlUserEntry 17 } + --1.3.6.1.4.1.3052.10.2.12.21.10.1.17 + +acuSatBegin OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Time of day (HH:MM) on Saturdays when this user should be granted access." + ::= { accessControlUserEntry 18 } + --1.3.6.1.4.1.3052.10.2.12.21.10.1.18 + +acuSatEnd OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Time of day (HH:MM) on Saturdays when this user should be forbidden access." + ::= { accessControlUserEntry 19 } + --1.3.6.1.4.1.3052.10.2.12.21.10.1.19 + + + +--*************************************************************************************** +--Telemetry Section 2.12.22 +--*************************************************************************************** + +telemetryTable OBJECT-TYPE + SYNTAX SEQUENCE OF TelemetryPoint + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "" + ::= { telemetry 1 } + --1.3.6.1.4.1.3052.10.2.12.22.1 + +telemetryEntry OBJECT-TYPE + SYNTAX TelemetryPoint + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry for table of telemetry points" + INDEX { telemetryPointIndex } + ::= { telemetryTable 1 } + --1.3.6.1.4.1.3052.10.2.12.22.1.1 + +telemetryPointIndex OBJECT-TYPE + SYNTAX Integer32 (1..256) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Index for table of telemetry points." + ::= { telemetryEntry 1 } + --1.3.6.1.4.1.3052.10.2.12.22.1.1.1 + +telemetryPointName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Name of telemetry point for information purpose only." + ::= { telemetryEntry 2 } + --1.3.6.1.4.1.3052.10.2.12.22.1.1.2 + +telemetryPointKey OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Key for telemetry point that specifies the telemetry data source." + ::= { telemetryEntry 3 } + --1.3.6.1.4.1.3052.10.2.12.22.1.1.3 + +telemetryPointType OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "DNP3 type for telemetry point" + ::= { telemetryEntry 4 } + --1.3.6.1.4.1.3052.10.2.12.22.1.1.4 + +telemetryPointClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "DNP3 class for telemetry point" + ::= { telemetryEntry 5 } + --1.3.6.1.4.1.3052.10.2.12.22.1.1.5 + +telemetryPointDeadband OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Deadband for telemetry point" + ::= { telemetryEntry 6 } + --1.3.6.1.4.1.3052.10.2.12.22.1.1.6 + +telemetryPointShortcode OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Shortcode for telemetry point" + ::= { telemetryEntry 7 } + --1.3.6.1.4.1.3052.10.2.12.22.1.1.7 + +--*************************************************************************************** +--Site Security Section 2.12.23 +--*************************************************************************************** + +siteSecIntrusionTable OBJECT-TYPE + SYNTAX SEQUENCE OF SiteSecIntrusion + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table of for Site Security" + ::= { siteSecurity 1 } + --1.3.6.1.4.1.3052.10.2.12.23.1 + +siteSecEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Security zone 1 to 10 is ON or OFF stating that a zone is configured properly" + ::= { siteSecIntrusionTable 1 } + --1.3.6.1.4.1.3052.10.2.12.23.1.1 + +siteSecDisarmed OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON or OFF if ON the zone will not detect intrusion because it is disarmed, OFF arms the zone to detect intrusion" + ::= { siteSecIntrusionTable 2 } + --1.3.6.1.4.1.3052.10.2.12.23.1.2 + + +siteSecName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The name given to the zone" + ::= { siteSecIntrusionTable 3 } + --1.3.6.1.4.1.3052.10.2.12.23.1.3 + + +siteSecState OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ALARM/DISARMED/DISABLED/INTRUDER/REARMING one of five states the zone is in" + ::= { siteSecIntrusionTable 4 } + --1.3.6.1.4.1.3052.10.2.12.23.1.4 + + +siteSecSensorES OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The Event Sensors related to a particular zone" + ::= { siteSecIntrusionTable 5 } + --1.3.6.1.4.1.3052.10.2.12.23.1.5 + + +siteSecSensorPoint OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The point in conjunction with event-sensor and zone" + ::= { siteSecIntrusionTable 6 } + --1.3.6.1.4.1.3052.10.2.12.23.1.6 + + +siteSecIntrusionThreshold OBJECT-TYPE + SYNTAX Integer32 (0..255) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Seconds to wait for a disarm event" + ::= { siteSecIntrusionTable 7 } + --1.3.6.1.4.1.3052.10.2.12.23.1.7 + + +siteSecReader OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Comma separated string of readers that disarms a zone" + ::= { siteSecIntrusionTable 8 } + --1.3.6.1.4.1.3052.10.2.12.23.1.8 + + +siteSecReaderThreshold OBJECT-TYPE + SYNTAX Integer32 (0..255) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The number of seconds a user has to disable a detected intrusion via the reader configured for the zone" + ::= { siteSecIntrusionTable 9 } + --1.3.6.1.4.1.3052.10.2.12.23.1.9 + + +siteSecButtonEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Button to disable an alarm is PRESENT/NOT PRESENT" + ::= { siteSecIntrusionTable 10 } + --1.3.6.1.4.1.3052.10.2.12.23.1.10 + + +siteSecButtonES OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Configured event-sensor for the Site-Security button" + ::= { siteSecIntrusionTable 11 } + --1.3.6.1.4.1.3052.10.2.12.23.1.11 + + +siteSecButtonPoint OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Configured pont for the Site-Security button" + ::= { siteSecIntrusionTable 12 } + --1.3.6.1.4.1.3052.10.2.12.23.1.12 + + +siteSecButtonType OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Button type configured : MOMENTARY/TOGGLE" + ::= { siteSecIntrusionTable 13 } + --1.3.6.1.4.1.3052.10.2.12.23.1.13 + + +siteSecButtonThresholdArm OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Seconds to hold button to arm a zone" + ::= { siteSecIntrusionTable 14 } + --1.3.6.1.4.1.3052.10.2.12.23.1.14 + + +siteSecButtonThresholdDisarm OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Seconds to hold button to disarm a zone" + ::= { siteSecIntrusionTable 15 } + --1.3.6.1.4.1.3052.10.2.12.23.1.15 + + +siteSecSirenEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF enable realy output for siren" + ::= { siteSecIntrusionTable 16 } + --1.3.6.1.4.1.3052.10.2.12.23.1.16 + + +siteSecSirenES OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Event-sensor relay location of siren for the zone" + ::= { siteSecIntrusionTable 17 } + --1.3.6.1.4.1.3052.10.2.12.23.1.17 + + +siteSecSirenPoint OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Event-sensor point location of siren for the zone" + ::= { siteSecIntrusionTable 18 } + --1.3.6.1.4.1.3052.10.2.12.23.1.18 + + +siteSecRearmDelay OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "A delay in seconds after a rearm event before the site is actually rearmed" + ::= { siteSecIntrusionTable 19 } + --1.3.6.1.4.1.3052.10.2.12.23.1.19 + +siteSecMotionTable OBJECT-TYPE + SYNTAX SEQUENCE OF SiteSecMotion + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table of for Site Security motion sensors" + ::= { siteSecurity 2 } + --1.3.6.1.4.1.3052.10.2.12.23.2 + +siteSecMotionES OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Event-sensor for motion detection device" + ::= { siteSecMotionTable 1 } + --1.3.6.1.4.1.3052.10.2.12.23.2.1 + + siteSecMotionPoint OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Point for event-sensor motion detection device" + ::= { siteSecMotionTable 2 } + --1.3.6.1.4.1.3052.10.2.12.23.2.2 + +siteSecMotionEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF enable or disable motion alarm" + ::= { siteSecMotionTable 3 } + --1.3.6.1.4.1.3052.10.2.12.23.2.3 + +siteSecMotionName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Name of the motion sensor" + ::= { siteSecMotionTable 4 } + --1.3.6.1.4.1.3052.10.2.12.23.2.4 + +siteSecMotionThresholdRearm OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "A threshold to wait for no motion before rearming" + ::= { siteSecMotionTable 5 } + --1.3.6.1.4.1.3052.10.2.12.23.2.5 + +siteSecDoorAjarTable OBJECT-TYPE + SYNTAX SEQUENCE OF SiteSecDoorAjar + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table of for Site Security Door Ajar sensors" + ::= { siteSecurity 3 } + --1.3.6.1.4.1.3052.10.2.12.23.3 + +siteSecDoorAjarEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF enable or disable door ajar sensor" + ::= { siteSecDoorAjarTable 1 } + --1.3.6.1.4.1.3052.10.2.12.23.3.1 + +siteSecDoorAjarName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Name for the door ajar sensor" + ::= { siteSecDoorAjarTable 2 } + --1.3.6.1.4.1.3052.10.2.12.23.3.2 + +siteSecDoorAjarES OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Event-sensor for door ajar detection device" + + ::= { siteSecDoorAjarTable 3 } + --1.3.6.1.4.1.3052.10.2.12.23.3.3 + +siteSecDoorAjarPoint OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Point for event-sensor door ajar detection device" + + ::= { siteSecDoorAjarTable 4 } + --1.3.6.1.4.1.3052.10.2.12.23.3.4 + +siteSecDoorAjarThresholdNormal OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Threshold to wait in seconds before tripping the door ajar alarm " + ::= { siteSecDoorAjarTable 5 } + --1.3.6.1.4.1.3052.10.2.12.23.3.5 + +siteSecDoorAjarThresholdExtraTime OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Extra seconds added to the door ajar threshold for disabled person before door ajar alarm is set" + ::= { siteSecDoorAjarTable 6 } + --1.3.6.1.4.1.3052.10.2.12.23.3.6 + + + +--*************************************************************************************** +--Action Section 2.14 +--*************************************************************************************** + + + +actionCallNumberTable OBJECT-TYPE + SYNTAX SEQUENCE OF ActionCallNumberConfig + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table of phone numbers to dial for modem actions" + ::= { action 1 } + --1.3.6.1.4.1.3052.10.2.14.1 + +actionCallNumberEntry OBJECT-TYPE + SYNTAX ActionCallNumberConfig + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry for table of phone numbers to dial for modem actions" + INDEX { actionCallNumberIndex } + ::= { actionCallNumberTable 1 } + --1.3.6.1.4.1.3052.10.2.14.1.1 + +actionCallNumberIndex OBJECT-TYPE + SYNTAX Integer32 (1..4) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Index for table of phone numbers to dial for modem actions" + ::= { actionCallNumberEntry 1 } + --1.3.6.1.4.1.3052.10.2.14.1.1.1 + +actionCallNumber OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The number to dial for this action slot" + ::= { actionCallNumberEntry 2 } + --1.3.6.1.4.1.3052.10.2.14.1.1.2 + +actionPagerTable OBJECT-TYPE + SYNTAX SEQUENCE OF ActionPagerConfig + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table of pager configurations" + ::= { action 2 } + --1.3.6.1.4.1.3052.10.2.14.2 + +actionPagerEntry OBJECT-TYPE + SYNTAX ActionPagerConfig + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry for table of pager configurations" + INDEX { actionPagerIndex } + ::= { actionPagerTable 1 } + --1.3.6.1.4.1.3052.10.2.14.2.1 + +actionPagerIndex OBJECT-TYPE + SYNTAX Integer32 (1..4) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "index for table of pager configurations" + ::= { actionPagerEntry 1 } + --1.3.6.1.4.1.3052.10.2.14.2.1.1 + +actionPagerType OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "type of this pager configuration" + ::= { actionPagerEntry 2 } + --1.3.6.1.4.1.3052.10.2.14.2.1.2 + +actionPagerNumber OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "phone number to dial for this pager configuration" + ::= { actionPagerEntry 3 } + --1.3.6.1.4.1.3052.10.2.14.2.1.3 + +actionPagerID OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ID to use for this pager configuration" + ::= { actionPagerEntry 4 } + --1.3.6.1.4.1.3052.10.2.14.2.1.4 + +actionPagerMessage OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "message to use for this pager configuration" + ::= { actionPagerEntry 5 } + --1.3.6.1.4.1.3052.10.2.14.2.1.5 + +actionPagerPostCalloutDelay OBJECT-TYPE + SYNTAX Integer32 (0..255) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Seconds to wait after dialing before sending ID" + ::= { actionPagerEntry 6 } + --1.3.6.1.4.1.3052.10.2.14.2.1.6 + +actionPagerPostIDDelay OBJECT-TYPE + SYNTAX Integer32 (0..255) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Seconds to wait after sending ID to send message" + ::= { actionPagerEntry 7 } + --1.3.6.1.4.1.3052.10.2.14.2.1.7 + +actionSchedEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF enable action schedule" + ::= { actionSched 1 } + --1.3.6.1.4.1.3052.10.2.14.3.1 + +actionSchedBegin OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "action schedule begin time (HH:MM)" + ::= { actionSched 2 } + --1.3.6.1.4.1.3052.10.2.14.3.2 + +actionSchedEnd OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "action schedule end time (HH:MM)" + ::= { actionSched 3 } + --1.3.6.1.4.1.3052.10.2.14.3.3 + +actionSchedWeekdaysOnly OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF whether the action schedule applies to weekdays only + (ON) or all days (OFF)" + ::= { actionSched 4 } + --1.3.6.1.4.1.3052.10.2.14.3.4 + +actionAsentriaRequireAck OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF Asentria action requires an ack from the receiver" + ::= { actionAsentria 1 } + --1.3.6.1.4.1.3052.10.2.14.4.1 + +actionAsentriaVersion OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "version 1.0 or 1.1" + ::= { actionAsentria 2 } + --1.3.6.1.4.1.3052.10.2.14.4.2 + +actionAsentriaTCPPort OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "TCP port used for TCP-based Asentria alarms" + ::= { actionAsentria 3 } + --1.3.6.1.4.1.3052.10.2.14.4.3 + +actionHostTable OBJECT-TYPE + SYNTAX SEQUENCE OF ActionHostConfig + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table of network hosts to use for network-based actions" + ::= { action 6 } + --1.3.6.1.4.1.3052.10.2.14.6 + +actionHostEntry OBJECT-TYPE + SYNTAX ActionHostConfig + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry for table of network hosts to use for network-based + actions" + INDEX { actionHostIndex } + ::= { actionHostTable 1 } + --1.3.6.1.4.1.3052.10.2.14.6.1 + +actionHostIndex OBJECT-TYPE + SYNTAX Integer32 (1..6) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Index for table of network hosts to use for network-based + actions" + ::= { actionHostEntry 1 } + --1.3.6.1.4.1.3052.10.2.14.6.1.1 + +actionHost OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Hostname/IP address used as destination for network-based + action (e.g., trap)" + ::= { actionHostEntry 2 } + --1.3.6.1.4.1.3052.10.2.14.6.1.2 + +actionEmailTable OBJECT-TYPE + SYNTAX SEQUENCE OF ActionEmailConfig + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table of email addresses to use for email actions" + ::= { action 7 } + --1.3.6.1.4.1.3052.10.2.14.7 + +actionEmailEntry OBJECT-TYPE + SYNTAX ActionEmailConfig + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry for table of email addresses to use for email actions" + INDEX { actionEmailIndex } + ::= { actionEmailTable 1 } + --1.3.6.1.4.1.3052.10.2.14.7.1 + +actionEmailIndex OBJECT-TYPE + SYNTAX Integer32 (1..6) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Index for table of email addresses to use for email actions" + ::= { actionEmailEntry 1 } + --1.3.6.1.4.1.3052.10.2.14.7.1.1 + +actionEmail OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "email address" + ::= { actionEmailEntry 2 } + --1.3.6.1.4.1.3052.10.2.14.7.1.2 + +actionParseError OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "When a user attempts to configure an invalid action setting/ + object, this object says why it was invalid." + ::= { action 8 } + --1.3.6.1.4.1.3052.10.2.14.8 + +--*************************************************************************************** +--System Section 2.16 +--*************************************************************************************** + + +sysTimeAutoDST OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF automatically adjust for Daylight Savings Time" + ::= { sysTime 1 } + --1.3.6.1.4.1.3052.10.2.16.1.1 + +sysTimeGMTOffset OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Absolute value of offset (hours) from GMT of the timezone" + ::= { sysTime 2 } + --1.3.6.1.4.1.3052.10.2.16.1.2 + +sysTimeGMTDirection OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Direction (AHEAD/BEHIND) of timezone relative to GMT" + ::= { sysTime 3 } + --1.3.6.1.4.1.3052.10.2.16.1.3 + + +sysTimeNetEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Network time mode" + ::= { sysTimeNet 1 } + --1.3.6.1.4.1.3052.10.2.16.1.4.1 + +sysTimeNetHostTable OBJECT-TYPE + SYNTAX SEQUENCE OF NetworkTimeHostConfig + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table of hosts to use for network time services" + ::= { sysTimeNet 2 } + --1.3.6.1.4.1.3052.10.2.16.1.4.2 + +sysTimeNetHostEntry OBJECT-TYPE + SYNTAX NetworkTimeHostConfig + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry for table of hosts to use for network time services" + INDEX { sysTimeNetHostIndex } + ::= { sysTimeNetHostTable 1 } + --1.3.6.1.4.1.3052.10.2.16.1.4.2.1 + +sysTimeNetHostIndex OBJECT-TYPE + SYNTAX Integer32 (1..6) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Index for table of hosts to use for network time services" + ::= { sysTimeNetHostEntry 1 } + --1.3.6.1.4.1.3052.10.2.16.1.4.2.1.1 + +sysTimeNetHost OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "host to use for network time services" + ::= { sysTimeNetHostEntry 2 } + --1.3.6.1.4.1.3052.10.2.16.1.4.2.1.2 + +sysPTTimeout OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Timeout (minutes) of inactivity after which a pass-through + session is terminated (0 means it never terminates)" + ::= { sysPT 1 } + --1.3.6.1.4.1.3052.10.2.16.2.1 + +sysPTEndPause OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "number of 16ths of a second between escape characters + received on pass-through origin IO handle that are reuired + for the escape characters to register as pass-through escape + characters in the pass-through escape sequence. Set to 0 to + make the escape character register as part of the pass- + through escape sequence without requiring a pause." + ::= { sysPT 2 } + --1.3.6.1.4.1.3052.10.2.16.2.2 + +sysPTJoinable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable joinable pass-through sessions." + ::= { sysPT 3 } + --1.3.6.1.4.1.3052.10.2.16.2.3 + +sysMTU OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Maximum transfer unit for ethernet interfaces" + ::= { sys 3 } + --1.3.6.1.4.1.3052.10.2.16.3 + +sysAnswerString OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "String displayed upon login" + ::= { sys 4 } + --1.3.6.1.4.1.3052.10.2.16.4 + +sysEventFileID OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ID string for events file" + ::= { sys 6 } + --1.3.6.1.4.1.3052.10.2.16.6 + +sysEscapeCharacter OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Decimal ASCII code of the system escape character" + ::= { sys 7 } + --1.3.6.1.4.1.3052.10.2.16.7 + +sysTimeStampTimeFormat OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Format of time stamp: HH:MM,HH:MM:SS,BLANK" + ::= { sysTimeStamp 1 } + --1.3.6.1.4.1.3052.10.2.16.8.1 + +sysTimeStampDateFormat OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Format of date stamp: MM/DD,MM/DD/YY,MM/DD/YYYY,BLANK" + ::= { sysTimeStamp 2 } + --1.3.6.1.4.1.3052.10.2.16.8.2 + +sysTimeStampSpaceAfter OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF Inlude a space after timestamp" + ::= { sysTimeStamp 3 } + --1.3.6.1.4.1.3052.10.2.16.8.3 + +sysLogMode OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Syslog mode: disabled, emit UDP (REMOTE), save in a + rotating file set (FILE), or emit on a listening socket + (SERVER)" + ::= { sysLog 1 } + --1.3.6.1.4.1.3052.10.2.16.9.1 + +sysLoghost OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Syslog host: destination machine when syslog mode is REMOTE" + ::= { sysLog 2 } + --1.3.6.1.4.1.3052.10.2.16.9.2 + +sysLogFilter OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "String describing what functions place data in the syslog" + ::= { sysLog 3 } + --1.3.6.1.4.1.3052.10.2.16.9.3 + +sysLogFileSize OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Size (in KB) of syslog files (when syslog mode is SERVER or + FILE)" + ::= { sysLog 4 } + --1.3.6.1.4.1.3052.10.2.16.9.4 + +sysLogFileCount OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Number of files in syslog file set (when syslog mode is + SERVER or FILE)" + ::= { sysLog 5 } + --1.3.6.1.4.1.3052.10.2.16.9.5 + +sysLogListenPort OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "TCP port on which the unit listens for a connection on + which syslog data is dumped (when syslog mode is SERVER)" + ::= { sysLog 6 } + --1.3.6.1.4.1.3052.10.2.16.9.6 + +sysCRDBCapacity OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Capacity of Call Record Database (in KB)" + ::= { sysCRDB 1 } + --1.3.6.1.4.1.3052.10.2.16.10.1 + +sysCRDBPercentFull OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Percent of the CRDB used" + ::= { sysCRDB 2 } + --1.3.6.1.4.1.3052.10.2.16.10.2 + + +sysCRDBFileIDTable OBJECT-TYPE + SYNTAX SEQUENCE OF CRDBFileIDConfig + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table of CRDB file IDs" + ::= { sysCRDB 3 } + --1.3.6.1.4.1.3052.10.2.16.10.3 + +sysCRDBFileIDEntry OBJECT-TYPE + SYNTAX CRDBFileIDConfig + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry for table of CRDB file IDs" + INDEX { sysCRDBFileIDIndex } + ::= { sysCRDBFileIDTable 1 } + --1.3.6.1.4.1.3052.10.2.16.10.3.1 + +sysCRDBFileIDIndex OBJECT-TYPE + SYNTAX Integer32 (1..16) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Index for table of CRDB file IDs" + ::= { sysCRDBFileIDEntry 1 } + --1.3.6.1.4.1.3052.10.2.16.10.3.1.1 + +sysCRDBFileID OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ID of CRDB file for this port-associated file x" + ::= { sysCRDBFileIDEntry 2 } + --1.3.6.1.4.1.3052.10.2.16.10.3.1.2 + +sysCRDBFileEnforceMinTable OBJECT-TYPE + SYNTAX SEQUENCE OF CRDBFileEnforceMinConfig + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table of CRDB file minimum size enforcement settings" + ::= { sysCRDB 4 } + --1.3.6.1.4.1.3052.10.2.16.10.4 + +sysCRDBFileEnforceMinEntry OBJECT-TYPE + SYNTAX CRDBFileEnforceMinConfig + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry for table of CRDB file minimum size enforcement + settings" + INDEX { sysCRDBFileEnforceMinIndex } + ::= { sysCRDBFileEnforceMinTable 1 } + --1.3.6.1.4.1.3052.10.2.16.10.4.1 + +sysCRDBFileEnforceMinIndex OBJECT-TYPE + SYNTAX Integer32 (1..24) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Index for table of CRDB file minimum size enforcement + settings" + ::= { sysCRDBFileEnforceMinEntry 1 } + --1.3.6.1.4.1.3052.10.2.16.10.4.1.1 + +sysCRDBFileEnforceMin OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF: enforce minimum size for this CRDB file x" + ::= { sysCRDBFileEnforceMinEntry 2 } + --1.3.6.1.4.1.3052.10.2.16.10.4.1.2 + +sysCharMask OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Character mask used for ignoring certain characters on + serial ports when assembling data records (when port mode is + ASCII)" + ::= { sys 11 } + --1.3.6.1.4.1.3052.10.2.16.11 + +sysPrompt OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Prompt to use in a commnand session" + ::= { sys 12 } + --1.3.6.1.4.1.3052.10.2.16.12 + +sysBootStatus OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "String describing the boot status of the unit (Booted OK/ + still booting" + ::= { sys 13 } + --1.3.6.1.4.1.3052.10.2.16.13 + +--*************************************************************************************** +--Sys Location Section 2.16.14 +--*************************************************************************************** + +sysLocLatitude OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Latitude portion of geographic coordinates as string" + ::= { sysLoc 1 } + --1.3.6.1.4.1.3052.10.2.16.14.1 + +sysLocLongitude OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Longitude portion of geographic coordinates as string" + ::= { sysLoc 2 } + --1.3.6.1.4.1.3052.10.2.16.14.2 + +sysLocXOffset OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "X-offset portion of geographic coordinates as string" + ::= { sysLoc 3 } + --1.3.6.1.4.1.3052.10.2.16.14.3 + +sysLocYOffset OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Y offset portion of geographic coordinates as string" + ::= { sysLoc 4 } + --1.3.6.1.4.1.3052.10.2.16.14.4 + +sysLocAngle OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Angle portion of geographic coordinates as string" + ::= { sysLoc 5 } + --1.3.6.1.4.1.3052.10.2.16.14.5 + +sysLocAltitude OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Altitude as string" + ::= { sysLoc 6 } + --1.3.6.1.4.1.3052.10.2.16.14.6 + +--*************************************************************************************** +--Sys Asset Managment 2.16.15 +--*************************************************************************************** +sysAMManufacturer OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Device manufacturer" + ::= { sysAssetMgmt 1 } + --1.3.6.1.4.1.3052.10.2.16.15.1 + +sysAMProduct OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Device product description (i.e., model or model number)" + ::= { sysAssetMgmt 2 } + --1.3.6.1.4.1.3052.10.2.16.15.2 + +sysAMSerialNumber OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Manufacturer serial number for device" + ::= { sysAssetMgmt 3 } + --1.3.6.1.4.1.3052.10.2.16.15.3 + +sysAMHardwareOptions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Hardware options currently installed on device" + ::= { sysAssetMgmt 4 } + --1.3.6.1.4.1.3052.10.2.16.15.4 + +sysAMSoftwareVersion OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Currently-running software version on device" + ::= { sysAssetMgmt 5 } + --1.3.6.1.4.1.3052.10.2.16.15.5 + +sysAMSiteName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Site Name of device (user definable, also known as the + siteName object under the productIds branch." + ::= { sysAssetMgmt 6 } + --1.3.6.1.4.1.3052.10.2.16.15.6 + + +--*************************************************************************************** +--Sys File Transfer Section 2.16.17 +--*************************************************************************************** + +sysFileTransferStatus OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Start/cancel file transfer, or check transfer status. To start, set this object + to 'start'. To cancel, set this object to 'cancel'. To check status, get the + object" + ::= { sysFileTransfer 1 } + --1.3.6.1.4.1.3052.10.2.16.17.1 + +sysFileTransferURL OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "URL (describing protocol, host, directory, and file) on which file transfer + function operates." + ::= { sysFileTransfer 2 } + --1.3.6.1.4.1.3052.10.2.16.17.2 + +sysFileTransferUsername OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Username for user account at the resource specified by sysFileTransferURL." + ::= { sysFileTransfer 3 } + --1.3.6.1.4.1.3052.10.2.16.17.3 + +sysFileTransferPassword OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Password for user account at the resource specified by sysFileTransferURL." + ::= { sysFileTransfer 4 } + --1.3.6.1.4.1.3052.10.2.16.17.4 + +--*************************************************************************************** +--Sys Update Section 2.16.18 +--*************************************************************************************** + +sysUpdateStatus OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Check time/result of last update attempt." + ::= { sysUpdate 1 } + --1.3.6.1.4.1.3052.10.2.16.18.1 + + +--*************************************************************************************** +--Audit Log Section 2.17 +--*************************************************************************************** + +auditLogEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF enable audit log" + ::= { auditLog 1 } + --1.3.6.1.4.1.3052.10.2.17.1 + +auditLogStoreResets OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF audit log stores when the unit resets" + ::= { auditLog 2 } + --1.3.6.1.4.1.3052.10.2.17.1 + +auditLogStoreCommands OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF audit log stores commands entered in a command + session" + ::= { auditLog 3 } + --1.3.6.1.4.1.3052.10.2.17.1 + +auditLogStoreOutputs OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF audit log stores output (relay output and power output) + activity" + ::= { auditLog 4 } + --1.3.6.1.4.1.3052.10.2.17.1 + +auditLogStoreAlarmActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF audit log stores action delivery activity" + ::= { auditLog 5 } + --1.3.6.1.4.1.3052.10.2.17.1 + +auditLogStorePwdFailures OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF audit log stores when user was denied login" + ::= { auditLog 6 } + --1.3.6.1.4.1.3052.10.2.17.1 + +auditLogStoreLogins OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF audit log stores when a user was allowed login" + ::= { auditLog 7 } + --1.3.6.1.4.1.3052.10.2.17.1 + +auditLogStoreSHSK OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF audit log stores serial handshaking status + (regardless of serial handshaking event)" + ::= { auditLog 8 } + --1.3.6.1.4.1.3052.10.2.17.1 + +auditLogStorePassthrough OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF audit log stores pass-through activity" + ::= { auditLog 9 } + --1.3.6.1.4.1.3052.10.2.17.1 + +auditLogStoreInactivity OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF audit log stores when sessions expire due to + inactivity" + ::= { auditLog 10 } + --1.3.6.1.4.1.3052.10.2.17.1 + +auditLogStorePolling OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF audit log stores CRDB polling activity" + ::= { auditLog 11 } + --1.3.6.1.4.1.3052.10.2.17.1 + +auditLogMaxSize OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Maximum size (in KB) of audit log" + ::= { auditLog 12 } + --1.3.6.1.4.1.3052.10.2.17.1 + +--*************************************************************************************** +--Scripting Section 2.17 +--*************************************************************************************** + +scrGlobalEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF enable scripting" + ::= { scripting 1 } + --1.3.6.1.4.1.3052.10.2.18.1 + +scrDTRCtrlPortEnableTable OBJECT-TYPE + SYNTAX SEQUENCE OF ScriptingDTRCtrlPortEnableConfig + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table of DTR control port enables" + ::= { scripting 2 } + --1.3.6.1.4.1.3052.10.2.18.2 + +scrDTRCtrlPortEnableEntry OBJECT-TYPE + SYNTAX ScriptingDTRCtrlPortEnableConfig + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry for table of DTR control port enables" + INDEX { scrDTRCtrlPortEnableIndex } + ::= { scrDTRCtrlPortEnableTable 1 } + --1.3.6.1.4.1.3052.10.2.18.2.1 + +scrDTRCtrlPortEnableIndex OBJECT-TYPE + SYNTAX Integer32 (1..16) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Index for table of DTR control port enables" + ::= { scrDTRCtrlPortEnableEntry 1 } + --1.3.6.1.4.1.3052.10.2.18.2.1.1 + +scrDTRCtrlPortEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF enable DTR control of scripting for this port" + ::= { scrDTRCtrlPortEnableEntry 2 } + --1.3.6.1.4.1.3052.10.2.18.2.1.2 + + +scrTable OBJECT-TYPE + SYNTAX SEQUENCE OF ScriptingConfig + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table of scripts" + ::= { scripting 3 } + --1.3.6.1.4.1.3052.10.2.18.3 + +scrEntry OBJECT-TYPE + SYNTAX ScriptingConfig + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry for table of scripts" + INDEX { scrIndex } + ::= { scrTable 1 } + --1.3.6.1.4.1.3052.10.2.18.3.1 + +scrIndex OBJECT-TYPE + SYNTAX Integer32 (1..20) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Index for table of scripts" + ::= { scrEntry 1 } + --1.3.6.1.4.1.3052.10.2.18.3.1.1 + +scrEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF enable this script" + ::= { scrEntry 2 } + --1.3.6.1.4.1.3052.10.2.18.3.1.2 + +scrName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Name of this script" + ::= { scrEntry 3 } + --1.3.6.1.4.1.3052.10.2.18.3.1.3 + +scrFilename OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Filename for this script" + ::= { scrEntry 4 } + --1.3.6.1.4.1.3052.10.2.18.3.1.4 + +scrRunAlways OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF: this script always runs" + ::= { scrEntry 5 } + --1.3.6.1.4.1.3052.10.2.18.3.1.5 + +scrRunAtStartup OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF: this script runs at startup" + ::= { scrEntry 6 } + --1.3.6.1.4.1.3052.10.2.18.3.1.6 + +scrRunScheduled OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ON/OFF: this script runs at a certain time of day" + ::= { scrEntry 7 } + --1.3.6.1.4.1.3052.10.2.18.3.1.7 + +scrScheduleTime OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Time of day (HH:MM) this script is scheduled to run" + ::= { scrEntry 8 } + --1.3.6.1.4.1.3052.10.2.18.3.1.8 + +scrArguments OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Arguments for this script" + ::= { scrEntry 9 } + --1.3.6.1.4.1.3052.10.2.18.3.1.9 + +scrRepeatInterval OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "How often this script runs (minutes)" + ::= { scrEntry 10 } + --1.3.6.1.4.1.3052.10.2.18.3.1.10 + +scrVolatileStringTable OBJECT-TYPE + SYNTAX SEQUENCE OF ScriptingVolatileString + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table of volatile string settings for use in + scripts." + ::= { scripting 4 } + --1.3.6.1.4.1.3052.10.2.18.4 + +scrVolatileStringEntry OBJECT-TYPE + SYNTAX ScriptingVolatileString + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry for table of volatile script string + settings" + INDEX { scrVolatileStringIndex } + ::= { scrVolatileStringTable 1 } + --1.3.6.1.4.1.3052.10.2.18.4.1 + +scrVolatileStringIndex OBJECT-TYPE + SYNTAX Integer32 (1..50) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Index for table of volatile script string + settings" + ::= { scrVolatileStringEntry 1 } + --1.3.6.1.4.1.3052.10.2.18.4.1.1 + +scrVolatileString OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Volatile string for use in scripts. Use this + object to cache frequently-changing string values + or string values that do not need to persist + through reset. This object corresponds to the + scripting.vstring[] setting key branch; use those + keys in scripts and you can view or change their + values with this object." + ::= { scrVolatileStringEntry 2 } + --1.3.6.1.4.1.3052.10.2.18.4.1.2 + +scrVolatileIntTable OBJECT-TYPE + SYNTAX SEQUENCE OF ScriptingVolatileInt + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table of volatile integer settings for use in + scripts." + ::= { scripting 5 } + --1.3.6.1.4.1.3052.10.2.18.5 + +scrVolatileIntEntry OBJECT-TYPE + SYNTAX ScriptingVolatileInt + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry for table of volatile script integer + settings" + INDEX { scrVolatileIntIndex } + ::= { scrVolatileIntTable 1 } + --1.3.6.1.4.1.3052.10.2.18.5.1 + +scrVolatileIntIndex OBJECT-TYPE + SYNTAX Integer32 (1..50) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Index for table of volatile script integer + settings" + ::= { scrVolatileIntEntry 1 } + --1.3.6.1.4.1.3052.10.2.18.5.1.1 + +scrVolatileInt OBJECT-TYPE + SYNTAX Integer32 (0..2147483647) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Volatile integer for use in scripts. Use this + object to cache frequently-changing integer values + or integer values that do not need to persist + through reset. This object corresponds to the + scripting.vint[] setting key branch; use those + keys in scripts and you can view or change their + values with this object." + ::= { scrVolatileIntEntry 2 } + --1.3.6.1.4.1.3052.10.2.18.5.1.2 + +scrNonVolatileStringTable OBJECT-TYPE + SYNTAX SEQUENCE OF ScriptingNonVolatileString + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table of non-volatile string settings for use in + scripts." + ::= { scripting 6 } + --1.3.6.1.4.1.3052.10.2.18.6 + +scrNonVolatileStringEntry OBJECT-TYPE + SYNTAX ScriptingNonVolatileString + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry for table of non-volatile script string + settings" + INDEX { scrNonVolatileStringIndex } + ::= { scrNonVolatileStringTable 1 } + --1.3.6.1.4.1.3052.10.2.18.6.1 + +scrNonVolatileStringIndex OBJECT-TYPE + SYNTAX Integer32 (1..50) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Index for table of non-volatile script string + settings" + ::= { scrNonVolatileStringEntry 1 } + --1.3.6.1.4.1.3052.10.2.18.6.1.1 + +scrNonVolatileString OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Non-volatile string for use in scripts. Use this + object to store values that need to persist + through reset. This object corresponds to the + scripting.nvstring[] setting key branch; use those + keys in scripts and you can view or change their + values with this object. Note: to store frequently- + changing integers, use the scrVolatileString object, + otherwise your scripts may cause unnecessary wear of + the non-volatile storage medium on the unit." + ::= { scrNonVolatileStringEntry 2 } + --1.3.6.1.4.1.3052.10.2.18.6.1.2 + +scrNonVolatileIntTable OBJECT-TYPE + SYNTAX SEQUENCE OF ScriptingNonVolatileInt + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table of non-volatile integer settings for use in + scripts." + ::= { scripting 7 } + --1.3.6.1.4.1.3052.10.2.18.7 + +scrNonVolatileIntEntry OBJECT-TYPE + SYNTAX ScriptingNonVolatileInt + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry for table of non-volatile script integer + settings" + INDEX { scrNonVolatileIntIndex } + ::= { scrNonVolatileIntTable 1 } + --1.3.6.1.4.1.3052.10.2.18.7.1 + +scrNonVolatileIntIndex OBJECT-TYPE + SYNTAX Integer32 (1..50) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Index for table of non-volatile script integer + settings" + ::= { scrNonVolatileIntEntry 1 } + --1.3.6.1.4.1.3052.10.2.18.7.1.1 + +scrNonVolatileInt OBJECT-TYPE + SYNTAX Integer32 (0..2147483647) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Non-volatile integer for use in scripts. Use this + object to store integer values that need to persist + through reset. This object corresponds to the + scripting.nvint[] setting key branch; use those + keys in scripts and you can view or change their + values with this object. Note: to store frequently- + changing integers, use the scrVolatileInt object, + otherwise your scripts may cause unnecessary wear of + the non-volatile storage medium on the unit." + ::= { scrNonVolatileIntEntry 2 } + --1.3.6.1.4.1.3052.10.2.18.7.1.2 + + +--*************************************************************************************** +--Generator Section 2.19 +--*************************************************************************************** + +genSetEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable genset functionality; that is, a generator is in use." + ::= { genSet 1 } + --1.3.6.1.4.1.3052.10.2.19.1.1 + +genSetRelayEs OBJECT-TYPE + SYNTAX Integer32 (1..200) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Which EventSensor has the relay which starts the generator, + for genset relay configuration 1 only. This object maps to the + same setting as genSetRelayTableEs.1." + ::= { genSetRelay 1 } + --1.3.6.1.4.1.3052.10.2.19.1.2.1 + +genSetRelayPoint OBJECT-TYPE + SYNTAX Integer32 (1..13) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Which relay starts the generator, for genset relay configuration + 1 only. This object maps to the same setting as genSetRelayTablePoint.1." + ::= { genSetRelay 2 } + --1.3.6.1.4.1.3052.10.2.19.1.2.2 + +genSetRelayRunningstate OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Which relay state corresponds with the generator starting/running. + This object maps to the same setting as genSetRelayTableRunningstate.1." + ::= { genSetRelay 3 } + --1.3.6.1.4.1.3052.10.2.19.1.2.3 + +genSetRelayTable OBJECT-TYPE + SYNTAX SEQUENCE OF GenSetRelaySequence + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table of relays for genset ignition." + ::= { genSetRelay 5 } + --1.3.6.1.4.1.3052.10.2.19.1.2.5 + +genSetRelayTableEntry OBJECT-TYPE + SYNTAX GenSetRelaySequence + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry for table of relays for genset ignition." + INDEX { genSetRelayTableIndex } + ::= { genSetRelayTable 1 } + --1.3.6.1.4.1.3052.10.2.19.1.2.5.1 + +genSetRelayTableIndex OBJECT-TYPE + SYNTAX Integer32 (1..2) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Index for table of relays for genset ignition." + ::= { genSetRelayTableEntry 1 } + --1.3.6.1.4.1.3052.10.2.19.1.2.5.1.1 + +genSetRelayTableEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable this relay for starting the generator." + ::= { genSetRelayTableEntry 2 } + --1.3.6.1.4.1.3052.10.2.19.1.2.5.1.2 + +genSetRelayTableEs OBJECT-TYPE + SYNTAX Integer32 (1..200) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Which EventSensor has the relay which starts the generator, for this + genset relay configuration specified by the table index." + ::= { genSetRelayTableEntry 3 } + --1.3.6.1.4.1.3052.10.2.19.1.2.5.1.3 + +genSetRelayTablePoint OBJECT-TYPE + SYNTAX Integer32 (1..13) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Which relay point on the EventSensor used for starting the generator, + for this genset relay configuration specified by the table index." + ::= { genSetRelayTableEntry 4 } + --1.3.6.1.4.1.3052.10.2.19.1.2.5.1.4 + +genSetRelayTableRunningstate OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Which relay state corresponds with the generator starting/running, + for this genset relay configuration specified by the table index." + ::= { genSetRelayTableEntry 5 } + --1.3.6.1.4.1.3052.10.2.19.1.2.5.1.5 + +genSetCCEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable generator running detection functionality; that is, the + associated CC is valid for determining if generator is running." + ::= { genSetCC 1 } + --1.3.6.1.4.1.3052.10.2.19.1.3.1 + +genSetCCEs OBJECT-TYPE + SYNTAX Integer32 (1..200) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Which CC EventSensor has the CC which is connected to the genertor + running detection monitor." + ::= { genSetCC 2 } + --1.3.6.1.4.1.3052.10.2.19.1.3.2 + +genSetCCPoint OBJECT-TYPE + SYNTAX Integer32 (1..64) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Which CC is connected to the genertor running detection monitor." + ::= { genSetCC 3 } + --1.3.6.1.4.1.3052.10.2.19.1.3.3 + +genSetCCRunningState OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Which CC physical state corresponds with the generator running." + ::= { genSetCC 4 } + --1.3.6.1.4.1.3052.10.2.19.1.3.4 + +genSetCCDelay OBJECT-TYPE + SYNTAX Integer32 (0..600) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "How long (in seconds) to wait for the generator to indicate + itself as running after engaging the generator-starting mechanism." + ::= { genSetCC 5 } + --1.3.6.1.4.1.3052.10.2.19.1.3.5 + + +genRunMode OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Generator Exercising function main operating mode; set to INHIBIT + to inhibit exercising the generator." + ::= { genRun 1 } + --1.3.6.1.4.1.3052.10.2.19.2.1 + +genRunSched OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Schedule number(s) which govern(s) when Generator Exercising function + runs." + ::= { genRun 2 } + --1.3.6.1.4.1.3052.10.2.19.2.2 + +genRunDuration OBJECT-TYPE + SYNTAX Integer32 (600..3600) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Number of seconds that generator should run, started when the + generator needs to start by SCHEDULE or by being forced to start." + ::= { genRun 3 } + --1.3.6.1.4.1.3052.10.2.19.2.3 + +genRunForce OBJECT-TYPE + SYNTAX Integer32 (0..1) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Write 1 to this to force the generator exercising to start. Always + reads as 0." + ::= { genRun 4 } + --1.3.6.1.4.1.3052.10.2.19.2.4 + +genRunReqasm OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Require ASM connectivity before starting the generator from a schedule." + ::= { genRun 5 } + --1.3.6.1.4.1.3052.10.2.19.2.5 + +genRunStatus OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Status of Generator Exercising function." + ::= { genRun 6 } + --1.3.6.1.4.1.3052.10.2.19.2.6 + + +genRunNonstartEventEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable generator non-start event." + ::= { genRunNonstartEvent 1 } + --1.3.6.1.4.1.3052.10.2.19.2.7.1 + +genRunNonstartEventActions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Actions for generator non-start event." + ::= { genRunNonstartEvent 2 } + --1.3.6.1.4.1.3052.10.2.19.2.7.2 + +genRunNonstartEventTrap OBJECT-TYPE + SYNTAX Integer32 (536..1199) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Trap number for generator non-start event." + ::= { genRunNonstartEvent 3 } + --1.3.6.1.4.1.3052.10.2.19.2.7.3 + +genRunNonstartEventClass OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Class (severity) for generator non-start event." + ::= { genRunNonstartEvent 4 } + --1.3.6.1.4.1.3052.10.2.19.2.7.4 + + +--*************************************************************************************** +--Calendar Section 2.20 +--*************************************************************************************** + +schedTable OBJECT-TYPE + SYNTAX SEQUENCE OF ScheduleConfig + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table of schedules" + ::= { calendar 1 } + --1.3.6.1.4.1.3052.10.2.20.1 + +schedEntry OBJECT-TYPE + SYNTAX ScheduleConfig + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry for table of schedules." + INDEX { schedIndex } + ::= { schedTable 1 } + --1.3.6.1.4.1.3052.10.2.20.1.1 + +schedIndex OBJECT-TYPE + SYNTAX Integer32 (1..8) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Index for table of schedules." + ::= { schedEntry 1 } + --1.3.6.1.4.1.3052.10.2.20.1.1.1 + +schedEnable OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable this schedule." + ::= { schedEntry 2 } + --1.3.6.1.4.1.3052.10.2.20.1.1.2 + +schedStart OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This is of the form 'mm/dd/yy hh:mm:ss'. This controls on which + date/time the schedule starts." + ::= { schedEntry 3 } + --1.3.6.1.4.1.3052.10.2.20.1.1.3 + +schedRepeatMode OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Controls in which way the schedule should repeat." + ::= { schedEntry 4 } + --1.3.6.1.4.1.3052.10.2.20.1.1.4 + +schedRepeatFreq OBJECT-TYPE + SYNTAX Integer32 (1..400) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Controls how often the schedule should repeat: every nth day, week, + month, or year." + ::= { schedEntry 5 } + --1.3.6.1.4.1.3052.10.2.20.1.1.5 + +schedRepeatEndMode OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Controls how the repeating schedule should end." + ::= { schedEntry 6 } + --1.3.6.1.4.1.3052.10.2.20.1.1.6 + +schedRepeatEndAfter OBJECT-TYPE + SYNTAX Integer32 (1..1000) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Number of times this schedule should be repeated; relevant when the + repeat end mode is AFTER." + ::= { schedEntry 7 } + --1.3.6.1.4.1.3052.10.2.20.1.1.7 + +schedRepeatEndOn OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Date/time (in the form 'mm/yy/dd hh:mm:ss' or blank string) after + which repeating should end, relevant when repeat end mode is ON DATE." + ::= { schedEntry 8 } + --1.3.6.1.4.1.3052.10.2.20.1.1.8 + +schedRepeatWeeklySun OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Run this schedule on Sunday(s); relevant when repeat mode is weekly." + ::= { schedEntry 9 } + --1.3.6.1.4.1.3052.10.2.20.1.1.9 + +schedRepeatWeeklyMon OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Run this schedule on Monday(s); relevant when repeat mode is weekly." + ::= { schedEntry 10 } + --1.3.6.1.4.1.3052.10.2.20.1.1.10 + +schedRepeatWeeklyTue OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Run this schedule on Tuesday(s); relevant when repeat mode is weekly." + ::= { schedEntry 11 } + --1.3.6.1.4.1.3052.10.2.20.1.1.11 + +schedRepeatWeeklyWed OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Run this schedule on Wednesday(s); relevant when repeat mode is weekly." + ::= { schedEntry 12 } + --1.3.6.1.4.1.3052.10.2.20.1.1.12 + +schedRepeatWeeklyThu OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Run this schedule on Thursday(s); relevant when repeat mode is weekly." + ::= { schedEntry 13 } + --1.3.6.1.4.1.3052.10.2.20.1.1.13 + +schedRepeatWeeklyFri OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Run this schedule on Friday(s); relevant when repeat mode is weekly." + ::= { schedEntry 14 } + --1.3.6.1.4.1.3052.10.2.20.1.1.14 + +schedRepeatWeeklySat OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Run this schedule on Saturday(s); relevant when repeat mode is weekly." + ::= { schedEntry 15 } + --1.3.6.1.4.1.3052.10.2.20.1.1.15 + +schedRepeatMonthlyMode OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "EACH means the schedule runs on specific dates of the month. ON THE + means the schedule runs on calculated dates of the month according to + which day that month starts." + ::= { schedEntry 16 } + --1.3.6.1.4.1.3052.10.2.20.1.1.16 + +schedRepeatMonthlyDates OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Comma-separated list of dates of a month on which this schedule should + run, relevant when repeat monthly mode is EACH." + ::= { schedEntry 17 } + --1.3.6.1.4.1.3052.10.2.20.1.1.17 + +schedRepeatMonthlyOnThe OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Controls on which day of the month this schedule should run, relevant + when repeat monthly mode is ON THE." + ::= { schedEntry 18 } + --1.3.6.1.4.1.3052.10.2.20.1.1.18 + +schedRepeatMonthlyOnDay OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Controls the day of week on which this schedule is run, relevant when + repeat monthly mode is ON THE" + ::= { schedEntry 19 } + --1.3.6.1.4.1.3052.10.2.20.1.1.19 + +schedRepeatYearlyJan OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Run this schedule in January, relevant when repeat mode is YEARLY." + ::= { schedEntry 20 } + --1.3.6.1.4.1.3052.10.2.20.1.1.20 + +schedRepeatYearlyFeb OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Run this schedule in February, relevant when repeat mode is YEARLY." + ::= { schedEntry 21 } + --1.3.6.1.4.1.3052.10.2.20.1.1.21 + +schedRepeatYearlyMar OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Run this schedule in March, relevant when repeat mode is YEARLY." + ::= { schedEntry 22 } + --1.3.6.1.4.1.3052.10.2.20.1.1.22 + +schedRepeatYearlyApr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Run this schedule in April, relevant when repeat mode is YEARLY." + ::= { schedEntry 23 } + --1.3.6.1.4.1.3052.10.2.20.1.1.23 + +schedRepeatYearlyMay OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Run this schedule in May, relevant when repeat mode is YEARLY." + ::= { schedEntry 24 } + --1.3.6.1.4.1.3052.10.2.20.1.1.24 + +schedRepeatYearlyJun OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Run this schedule in June, relevant when repeat mode is YEARLY." + ::= { schedEntry 25 } + --1.3.6.1.4.1.3052.10.2.20.1.1.25 + +schedRepeatYearlyJul OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Run this schedule in July, relevant when repeat mode is YEARLY." + ::= { schedEntry 26 } + --1.3.6.1.4.1.3052.10.2.20.1.1.26 + +schedRepeatYearlyAug OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Run this schedule in August, relevant when repeat mode is YEARLY." + ::= { schedEntry 27 } + --1.3.6.1.4.1.3052.10.2.20.1.1.27 + +schedRepeatYearlySep OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Run this schedule in September, relevant when repeat mode is YEARLY." + ::= { schedEntry 28 } + --1.3.6.1.4.1.3052.10.2.20.1.1.28 + +schedRepeatYearlyOct OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Run this schedule in October, relevant when repeat mode is YEARLY." + ::= { schedEntry 29 } + --1.3.6.1.4.1.3052.10.2.20.1.1.29 + +schedRepeatYearlyNov OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Run this schedule in November, relevant when repeat mode is YEARLY." + ::= { schedEntry 30 } + --1.3.6.1.4.1.3052.10.2.20.1.1.30 + +schedRepeatYearlyDec OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Run this schedule in December, relevant when repeat mode is YEARLY." + ::= { schedEntry 31 } + --1.3.6.1.4.1.3052.10.2.20.1.1.31 + +schedRepeatYearlyOnThe OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Controls on which day of the month this schedule should run, relevant + when repeat mode is YEARLY." + ::= { schedEntry 32 } + --1.3.6.1.4.1.3052.10.2.20.1.1.32 + +schedRepeatYearlyOnDay OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Controls the day of week on which this schedule is run, relevant when + repeat mode is YEARLY." + ::= { schedEntry 33 } + --1.3.6.1.4.1.3052.10.2.20.1.1.33 + +schedNextTrigger OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "When this schedule will next trigger." + ::= { schedEntry 34 } + --1.3.6.1.4.1.3052.10.2.20.1.1.34 + + +--*************************************************************************************** +--Product IDs Section 3 +--*************************************************************************************** + +siteName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Site Name string; Max 40 characters." + ::= { productIds 1 } + --1.3.6.1.4.1.3052.10.3.1 + +thisProduct OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This is a factory configured string for the + product name." + ::= { productIds 2 } + --1.3.6.1.4.1.3052.10.3.2 + +stockTrapString OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The message defined for the event that triggers a trap." + ::= { productIds 3 } + --1.3.6.1.4.1.3052.10.3.3 + +trapEventTypeNumber OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The user-defined trap variable for the type of + event that happened. Definitions: + 4 Scheduled + 7 Serial Handshaking Low + 8 Serial Handshaking High + 10 Contact Closure Active + 11 Contact Closure Inactive + 12 Temperature High + 13 Temperature Very High + 14 Temperature Low + 15 Temperature Very Low + 16 Temperature Return to Normal + 17 Humidity High + 18 Humidity Very High + 19 Humidity Low + 20 Humidity Very Low + 21 Humidity Return to Normal + 26 Analog High + 27 Analog Very High + 28 Analog Low + 29 Analog Very Low + 30 Analog Normal + 40 EventSensor Unresponsive + 41 Custom + 42 CPE Down + 44 CPE Normal + 49 Fuel Sensor Disconnect + 50 Fuel Sensor Disconnect Return to Normal + 56 Fuel Sensor + 57 AC Power Monitor Average Voltage Very Low + 58 AC Power Monitor Average Voltage Low + 59 AC Power Monitor Average Voltage Return to Normal + 60 AC Power Monitor Average Voltage High + 61 AC Power Monitor Average Voltage Very High + 62 AC Power Monitor Average Current Very Low + 63 AC Power Monitor Average Current Low + 64 AC Power Monitor Average Current Return to Normal + 65 AC Power Monitor Average Current High + 66 AC Power Monitor Average Current Very High + 67 AC Power Monitor Frequency Very Low + 68 AC Power Monitor Frequency Low + 69 AC Power Monitor Frequency Return to Normal + 70 AC Power Monitor Frequency High + 71 AC Power Monitor Frequency Very High + 72 AC Power Monitor Total Real Power Very Low + 73 AC Power Monitor Total Real Power Low + 74 AC Power Monitor Total Real Power Return to Normal + 75 AC Power Monitor Total Real Power High + 76 AC Power Monitor Total Real Power Very High + 77 AC Power Monitor Disconnect + 78 AC Power Monitor Disconnect Return to Normal + 81 Fuel Sensor Volume Sudden Change + 82 Fuel Sensor Volume Slow Change + 83 CPE Down Reminder + 84 AC Power Monitor Total Power Factor Very Low + 85 AC Power Monitor Total Power Factor Low + 86 AC Power Monitor Total Power Factor Return to Normal + 100 Contact Closure Active Reminder + 101 Temperature High Reminder + 102 Temperature High Very Reminder + 103 Temperature Low Reminder + 104 Temperature Very Low Reminder + 105 Humidity High Reminder + 106 Humidity Very High Reminder + 107 Humidity Low Reminder + 108 Humidity Very Low Reminder + 109 Analog High Reminder + 110 Analog Very High Reminder + 111 Analog Low Reminder + 112 Analog Very Low Reminder + 130 Relay Output Active + 131 Relay Output Inactive + 132 Power Output On + 133 Power Output Off + 161 Camera + 164 Reset + 166 Fuel Sensor Levels Auto Adjust + + " + ::= { productIds 4 } + --1.3.6.1.4.1.3052.10.3.4 + +trapEventTypeName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The user-defined trap variable for the string + corresponding to the event type." + ::= { productIds 5 } + --1.3.6.1.4.1.3052.10.3.5 + +trapIncludedValue OBJECT-TYPE + SYNTAX Integer32 (-2147483648..2147483647) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The user-defined trap variable for the generic + included value." + ::= { productIds 6 } + --1.3.6.1.4.1.3052.10.3.6 + +trapIncludedString OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The user-defined trap variable for the generic + included string." + ::= { productIds 7 } + --1.3.6.1.4.1.3052.10.3.7 + +trapTypeString OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The cause of the trap, added for DL880 compatibility." + ::= { productIds 8 } + --1.3.6.1.4.1.3052.10.3.8 + +trapEventClassNumber OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The user-defined trap variable for the configurable + class number associated with the triggering event." + ::= { productIds 9 } + --1.3.6.1.4.1.3052.10.3.9 + +trapEventClassName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The user-defined trap variable for the configurable + class name associated with the class number." + ::= { productIds 10 } + --1.3.6.1.4.1.3052.10.3.10 + + +--*************************************************************************************** +--Key Interface Section 4 +--*************************************************************************************** + +keyInterface OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object represents a setting key interface. When + setting this object, the value to set is the 'sk' command + you would enter on the command line (without the 'sk'). To + get the result of the operation, read this object after you + write it. + + For example, to configure EventSensor 1 contact closure 34 + event actions to be an SNMP InformRequest to host foo, set + this object to: + 'event.sensor[1].cc[34].eventactions=inform(foo)'. The SNMP + response is the result of the operation: if setting that key + to that value was a success then the SNMP response will be a + success and the response value will be what you had set. If + you subsequently read this object then you will see a + message 'OK: ...'. + + If setting that key to that value failed then the SNMP + response will be a failure (a badValue response). If you + subsequently read this object then the value returned is the + reason that setting that key to that value failed. + + For another example, to read user 3's pass-through access + for port 7, set this object to: + 'sec.user[3].port[7].ptaccess'. The SNMP response is the + result of the operation: if reading that key is a success + then the SNMP response will be a success and the response + value will be what you had SET (i.e., the opertion of + reading a key, which is just the key itself with no '=' + operator, and this is not the key value you want to read). + If you subsequently read this object then the value + returned is the value of the key you want to read. + + If reading that key failed (e.g., if the key is invalid) + then the SNMP response to your SNMP set operation (the + value you set being the invalid key to read) will be a + failure (a badValue response). If you subsequently read + this object then the value returned is the reason that + reading that key failed (i.e., 'invalid key')." + ::= { s550 4 } + --1.3.6.1.4.1.3052.10.4 + + +--*************************************************************************************** +--TABLE DEFINITIONS +--*************************************************************************************** + +ESPointConfigTemp ::= + SEQUENCE { + espcTempIndexES + Integer32, + espcTempIndexPoint + Integer32, + espcTempEnable + DisplayString, + espcTempScale + DisplayString, + espcTempDeadband + DisplayString, + espcTempVHighTemp + DisplayString, + espcTempVHighActions + DisplayString, + espcTempVHighTrapnum + Integer32, + espcTempVHighClass + DisplayString, + espcTempHighTemp + DisplayString, + espcTempHighActions + DisplayString, + espcTempHighTrapnum + Integer32, + espcTempHighClass + DisplayString, + espcTempNormalActions + DisplayString, + espcTempNormalTrapnum + Integer32, + espcTempNormalClass + DisplayString, + espcTempLowTemp + DisplayString, + espcTempLowActions + DisplayString, + espcTempLowTrapnum + Integer32, + espcTempLowClass + DisplayString, + espcTempVLowTemp + DisplayString, + espcTempVLowActions + DisplayString, + espcTempVLowTrapnum + Integer32, + espcTempVLowClass + DisplayString, + espcTempGroup + DisplayString +} + + +ESPointConfigCC ::= + SEQUENCE { + espcCCIndexES + Integer32, + espcCCIndexPoint + Integer32, + espcCCEnable + DisplayString, + espcCCName + DisplayString, + espcCCEventState + DisplayString, + espcCCThreshold + Integer32, + espcCCEventActions + DisplayString, + espcCCEventTrapnum + Integer32, + espcCCEventClass + DisplayString, + espcCCNormalActions + DisplayString, + espcCCNormalTrapnum + Integer32, + espcCCNormalClass + DisplayString, + espcCCAlarmAlias + DisplayString, + espcCCNormalAlias + DisplayString, + espcCCNormalThreshold + Integer32, + espcCCOverrideGlobalReminder + DisplayString, + espcCCReminderInterval + Integer32, + espcCCGroup + DisplayString +} + +ESPointConfigHumid ::= + SEQUENCE { + espcHumidIndexES + Integer32, + espcHumidIndexPoint + Integer32, + espcHumidEnable + DisplayString, + espcHumidDeadband + Integer32, + espcHumidVHighHumid + Integer32, + espcHumidVHighActions + DisplayString, + espcHumidVHighTrapnum + Integer32, + espcHumidVHighClass + DisplayString, + espcHumidHighHumid + Integer32, + espcHumidHighActions + DisplayString, + espcHumidHighTrapnum + Integer32, + espcHumidHighClass + DisplayString, + espcHumidNormalActions + DisplayString, + espcHumidNormalTrapnum + Integer32, + espcHumidNormalClass + DisplayString, + espcHumidLowHumid + Integer32, + espcHumidLowActions + DisplayString, + espcHumidLowTrapnum + Integer32, + espcHumidLowClass + DisplayString, + espcHumidVLowHumid + Integer32, + espcHumidVLowActions + DisplayString, + espcHumidVLowTrapnum + Integer32, + espcHumidVLowClass + DisplayString, + espcHumidGroup + DisplayString +} + +ESPointConfigAnalogInput ::= + SEQUENCE { + espcAIIndexES + Integer32, + espcAIIndexPoint + Integer32, + espcAIEnable + DisplayString, + espcAIDeadband + DisplayString, + espcAIVhighValue + DisplayString, + espcAIVhighActions + DisplayString, + espcAIVhighTrapnum + Integer32, + espcAIVhighClass + DisplayString, + espcAIHighValue + DisplayString, + espcAIHighActions + DisplayString, + espcAIHighTrapnum + Integer32, + espcAIHighClass + DisplayString, + espcAINormalActions + DisplayString, + espcAINormalTrapnum + Integer32, + espcAINormalClass + DisplayString, + espcAILowValue + DisplayString, + espcAILowActions + DisplayString, + espcAILowTrapnum + Integer32, + espcAILowClass + DisplayString, + espcAIVlowValue + DisplayString, + espcAIVlowActions + DisplayString, + espcAIVlowTrapnum + Integer32, + espcAIVlowClass + DisplayString, + espcAIConvUnitName + DisplayString, + espcAIConvHighValue + DisplayString, + espcAIConvHighUnit + DisplayString, + espcAIConvLowValue + DisplayString, + espcAIConvLowUnit + DisplayString, + espcAIDisplayFormat + DisplayString, + espcAIGroup + DisplayString +} + + +ActionCallNumberConfig ::= + SEQUENCE { + actionCallNumberIndex + Integer32, + actionCallNumber + DisplayString + +} + +ActionPagerConfig ::= + SEQUENCE { + actionPagerIndex + Integer32, + actionPagerType + DisplayString, + actionPagerNumber + DisplayString, + actionPagerID + DisplayString, + actionPagerMessage + DisplayString, + actionPagerPostCalloutDelay + Integer32, + actionPagerPostIDDelay + Integer32 +} + +ESPointConfigOutput ::= + SEQUENCE { + espcOutputIndexES + Integer32, + espcOutputIndexPoint + Integer32, + espcOutputEnable + DisplayString, + espcOutputActiveState + DisplayString, + espcOutputType + DisplayString, + espcOutputAliasValue + DisplayString, + espcOutputAliasColor + DisplayString, + espcOutputActiveAlias + DisplayString, + espcOutputActiveColor + DisplayString, + espcOutputActiveActions + DisplayString, + espcOutputActiveTrapnum + Integer32, + espcOutputActiveClass + DisplayString, + espcOutputInactiveAlias + DisplayString, + espcOutputInactiveColor + DisplayString, + espcOutputInactiveActions + DisplayString, + espcOutputInactiveTrapnum + Integer32, + espcOutputInactiveClass + DisplayString, + espcOutputGroup + DisplayString +} + +EventClassConfig ::= + SEQUENCE { + evClassNameIndex + Integer32, + evClassName + DisplayString +} + +RTSFileConfig ::= + SEQUENCE { + rtsFileIndex + Integer32, + rtsFileMode + DisplayString, + rtsFileShowAnswer + DisplayString, + rtsFileReqXON + DisplayString, + rtsFileTimeout + Integer32, + rtsFileEmptyClose + DisplayString, + rtsFilePushHost + DisplayString, + rtsFilePushPort + Integer32, + rtsFilePushRetryTimer + Integer32 +} + + +ModemCLIDLogConfig ::= + SEQUENCE { + modemCLIDLogIndex + Integer32, + modemCLIDLogNumber + DisplayString +} + +CPEConfig ::= + SEQUENCE { + cpeIndex + Integer32, + cpeHost + DisplayString, + cpeName + DisplayString, + cpeDescription + DisplayString, + cpeKeepalive + Integer32, + cpeThreshold + Integer32, + cpeEventReminderInterval + Integer32, + cpeKeepaliveTicks + Integer32, + cpePingSize + Integer32, + cpeInfoReset + Integer32, + cpeInfoNumReq + Integer32, + cpeInfoNumGoodResp + Integer32, + cpeInfoNumBadResp + Integer32, + cpeInfoNumLostResp + Integer32, + cpeInfoPercentLoss + DisplayString, + cpeInfoPercentBad + DisplayString +} + +ScriptingConfig ::= + SEQUENCE { + scrIndex + Integer32, + scrEnable + DisplayString, + scrName + DisplayString, + scrFilename + DisplayString, + scrRunAlways + DisplayString, + scrRunAtStartup + DisplayString, + scrRunScheduled + DisplayString, + scrScheduleTime + DisplayString, + scrArguments + DisplayString, + scrRepeatInterval + Integer32 +} + +ScriptingDTRCtrlPortEnableConfig ::= + SEQUENCE { + scrDTRCtrlPortEnableIndex + Integer32, + scrDTRCtrlPortEnable + DisplayString + +} + +ScriptingVolatileString ::= + SEQUENCE { + scrVolatileStringIndex + Integer32, + scrVolatileString + DisplayString +} + +ScriptingVolatileInt ::= + SEQUENCE { + scrVolatileIntIndex + Integer32, + scrVolatileInt + Integer32 +} + +ScriptingNonVolatileString ::= + SEQUENCE { + scrNonVolatileStringIndex + Integer32, + scrNonVolatileString + DisplayString +} + +ScriptingNonVolatileInt ::= + SEQUENCE { + scrNonVolatileIntIndex + Integer32, + scrNonVolatileInt + Integer32 +} + +GenSetRelaySequence ::= + SEQUENCE { + genSetRelayTableIndex + Integer32, + genSetRelayTableEnable + DisplayString, + genSetRelayTableEs + Integer32, + genSetRelayTablePoint + Integer32, + genSetRelayTableRunningstate + DisplayString +} + +CRDBFileEnforceMinConfig ::= + SEQUENCE { + sysCRDBFileEnforceMinIndex + Integer32, + sysCRDBFileEnforceMin + DisplayString +} + +CRDBFileIDConfig ::= + SEQUENCE { + sysCRDBFileIDIndex + Integer32, + sysCRDBFileID + DisplayString +} + +NetworkTimeHostConfig ::= + SEQUENCE { + sysTimeNetHostIndex + Integer32, + sysTimeNetHost + DisplayString +} + +ActionHostConfig ::= + SEQUENCE { + actionHostIndex + Integer32, + actionHost + DisplayString +} + +ActionEmailConfig ::= + SEQUENCE { + actionEmailIndex + Integer32, + actionEmail + DisplayString +} + +FileEnforceMinimumConfig ::= + SEQUENCE { + sysCRDBFileEnforceMinIndex + Integer32, + sysCRDBFileEnforceMin + DisplayString +} + +SerialHandshakingLowEventConfig ::= + SEQUENCE { + evShskLowIndex + Integer32, + evShskLowEnable + DisplayString, + evShskLowActions + DisplayString, + evShskLowMessage + DisplayString, + evShskLowClass + DisplayString, + evShskLowTrapNum + Integer32 +} + +SerialHandshakingHighEventConfig ::= + SEQUENCE { + evShskHighIndex + Integer32, + evShskHighEnable + DisplayString, + evShskHighActions + DisplayString, + evShskHighMessage + DisplayString, + evShskHighClass + DisplayString, + evShskHighTrapNum + Integer32 +} + +NoDataEvent1PortEnableConfig ::= + SEQUENCE { + evNoData1PortEnableIndex + Integer32, + evNoData1PortEnable + DisplayString +} + +NoDataEvent2PortEnableConfig ::= + SEQUENCE { + evNoData2PortEnableIndex + Integer32, + evNoData2PortEnable + DisplayString +} + +DataEventMacroConfig ::= + SEQUENCE { + evdMacroIndex + Integer32, + evdMacroName + DisplayString, + evdMacroEquation + DisplayString +} + +DataEventFieldConfig ::= + SEQUENCE { + evdFieldIndex + Integer32, + evdFieldStart + Integer32, + evdFieldLength + Integer32, + evdFieldName + DisplayString, + evdFieldLine + Integer32, + evdFieldType + DisplayString +} + +DataEventConfig ::= + SEQUENCE { + evdIndex + Integer32, + evdEnable + DisplayString, + evdName + DisplayString, + evdEquation + DisplayString, + evdThreshold + Integer32, + evdAutoClear + DisplayString, + evdClearInterval + DisplayString, + evdClearTime + DisplayString, + evdActions + DisplayString, + evdClass + DisplayString, + evdTrapNum + Integer32, + evdMode + DisplayString +} + +SecUserConfig ::= + SEQUENCE { + secUserIndex + Integer32, + secUserEnable + DisplayString, + secUserConnectVia + DisplayString, + secUserLoginTo + DisplayString, + secUserAccessFile + DisplayString, + secUserPTEscapeTo + DisplayString, + secUserPPPType + DisplayString, + secUserRights + DisplayString, + secUserEventsReadAccess + DisplayString, + secUserAuditReadAccess + DisplayString, + secUserEventsWriteAccess + DisplayString, + secUserAuditWriteAccess + DisplayString, + secUserExpiration + DisplayString, + secUserCallbackNumber1 + DisplayString, + secUserCallbackNumber2 + DisplayString, + secUserCallbackNumber3 + DisplayString, + secUserChallengeTelnetMode + DisplayString, + secUserChallengeModemMode + DisplayString, + secUserChallengeConsoleMode + DisplayString, + secUserChallengeTelnetSendTo + DisplayString, + secUserChallengeModemSendTo + DisplayString, + secUserChallengeExpiration + Integer32 +} + + + + +ModemCLIDNumberConfig ::= + SEQUENCE { + modemCLIDNumberIndex + Integer32, + modemCLIDNumber + DisplayString +} + + +RouteTestConfig ::= + SEQUENCE { + routeTestAddressIndex + Integer32, + routeTestAddress + DisplayString +} + +IPRestrictionConfig ::= + SEQUENCE { + ipRestrictionIndex + Integer32, + ipRestrictionEnable + DisplayString, + ipRestrictionMask + DisplayString +} + +DNSConfig ::= + SEQUENCE { + dnsIndex + Integer32, + dnsAddress + IpAddress +} + +HostConfig ::= + SEQUENCE { + hostIndex + Integer32, + hostDeclaration + DisplayString +} + +SNMPProxyTable ::= + SEQUENCE { + snmpProxyIndex + Integer32, + snmpProxyEgressOIDBranch + DisplayString, + snmpProxyIP + DisplayString, + snmpProxyPort + Integer32, + snmpProxyIngressOIDBranch + DisplayString, + snmpProxyName + DisplayString +} + +SNMPPollRequestConfig ::= + SEQUENCE { + snmpPRequestIndex + Integer32, + snmpPRequestDescription + DisplayString, + snmpPRequestAgent + DisplayString, + snmpPRequestReadcom + DisplayString, + snmpPRequestOID + DisplayString, + snmpPRequestPeriod + Integer32, + snmpPRequestID + DisplayString, + snmpPRequestThreshold + DisplayString, + snmpPRequestResultStatus + DisplayString, + snmpPRequestResultValue + DisplayString, + snmpPRequestResultTime + DisplayString, + snmpPRequestResultType + DisplayString +} + +FTPPushPushFileConfig ::= + SEQUENCE { + ftpPushPushFileIndex + Integer32, + ftpPushPushFile + DisplayString +} + +FTPPushRemoteFileConfig ::= + SEQUENCE { + ftpPushRemoteFileIndex + Integer32, + ftpPushRemoteFileName + DisplayString +} + +PortConfig ::= + SEQUENCE { + portConfigIndex + Integer32, + portConfigBaud + Integer32, + portConfigDataFormat + Integer32, + portConfigStripPtOutputLfs + Integer32, + portConfigStripPtInputLfs + Integer32, + portConfigMaskEnable + Integer32, + portConfigDAEnable + Integer32, + portConfigStoreAlarmsDPT + DisplayString, + portConfigRecordTimeout + Integer32, + portConfigDataType + DisplayString, + portConfigEtxToCRLF + DisplayString, + portConfigMLREnable + DisplayString, + portConfigMLRStartField1Pos + Integer32, + portConfigMLRStartField1Text + DisplayString, + portConfigMLRStartField2Pos + Integer32, + portConfigMLRStartField2Text + DisplayString, + portConfigMLRNumLinesBefore + Integer32, + portConfigMLREndDetection + DisplayString, + portConfigMLRLineCount + Integer32, + portConfigMLREndField1Pos + Integer32, + portConfigMLREndField1Text + DisplayString, + portConfigMLREndField2Pos + Integer32, + portConfigMLREndField2Text + DisplayString, + portConfigMLRUseComplexRules + DisplayString, + portConfigBufferPT + DisplayString, + portConfigId + DisplayString, + portConfigMode + DisplayString, + portConfigHsk + DisplayString + +} + +ESPoint ::= + SEQUENCE { + esIndexES + Integer32, + esIndexPC + Integer32, + esIndexPoint + Integer32, + esPointName + DisplayString, + esPointInEventState + Integer32, + esPointValueInt + Integer32, + esPointValueStr + DisplayString, + esPointTimeLastChange + DisplayString, + esPointTimetickLastChange + TimeTicks, + esPointAliasValueStr + DisplayString, + esPointClassValueStr + DisplayString +} + +ESExist ::= + SEQUENCE { + esIndex + Integer32, + esName + DisplayString, + esID + DisplayString, + esNumberTempSensors + Integer32, + esTempReportingMode + DisplayString, + esNumberCCs + Integer32, + esCCReportingMode + DisplayString, + esNumberHumidSensors + Integer32, + esHumidReportingMode + DisplayString, + esNumberNoiseSensors + Integer32, + esNoiseReportingMode + DisplayString, + esNumberAirflowSensors + Integer32, + esAirflowReportingMode + DisplayString, + esNumberAnalog + Integer32, + esAnalogReportingMode + DisplayString, + esNumberOutputs + Integer32, + esOutputReportingMode + DisplayString, + esTempCombinedStatus + DisplayString, + esCCCombinedStatusBlock1 + DisplayString, + esCCCombinedStatusBlock2 + DisplayString, + esCCCombinedStatusBlock3 + DisplayString, + esCCCombinedStatusBlock4 + DisplayString, + esCCCombinedStatusBlock5 + DisplayString, + esCCCombinedStatusBlock6 + DisplayString, + esCCCombinedStatusBlock7 + DisplayString, + esCCCombinedStatusBlock8 + DisplayString, + esHumidCombinedStatus + DisplayString, + esAnalogCombinedStatusBlock1 + DisplayString, + esAnalogCombinedStatusBlock2 + DisplayString, + esAnalogCombinedStatusBlock3 + DisplayString, + esAnalogCombinedStatusBlock4 + DisplayString, + esAnalogCombinedStatusBlock5 + DisplayString, + esAnalogCombinedStatusBlock6 + DisplayString, + esOutputCombinedStatusBlock1 + DisplayString, + esOutputCombinedStatusBlock2 + DisplayString +} + +DEStatus ::= + SEQUENCE { + deStatusIndex + Integer32, + deStatusName + DisplayString, + deStatusCounter + Integer32, + deStatusThreshold + Integer32 +} + +FSStatus ::= + SEQUENCE { + fsStatusIndex + Integer32, + fsStatusName + DisplayString, + fsStatusDeviceState + DisplayString, + fsStatusVolumeValueString + DisplayString, + fsStatusVolumePercentLevel + DisplayString, + fsStatusVolumeInEventState + DisplayString, + fsStatusCombined + DisplayString +} + +ACPMStatus ::= + SEQUENCE { + acpmsIndex + Integer32, + acpmsName + DisplayString, + acpmsAvgVoltageValueStr + DisplayString, + acpmsAvgVoltageMinStr + DisplayString, + acpmsAvgVoltageMaxStr + DisplayString, + acpmsAvgVoltageAvgStr + DisplayString, + acpmsAvgVoltageInEventState + DisplayString, + acpmsVoltagePhaseAValueStr + DisplayString, + acpmsVoltagePhaseBValueStr + DisplayString, + acpmsVoltagePhaseCValueStr + DisplayString, + acpmsAvgCurrentValueStr + DisplayString, + acpmsAvgCurrentMinStr + DisplayString, + acpmsAvgCurrentMaxStr + DisplayString, + acpmsAvgCurrentAvgStr + DisplayString, + acpmsAvgCurrentInEventState + DisplayString, + acpmsCurrentPhaseAValueStr + DisplayString, + acpmsCurrentPhaseBValueStr + DisplayString, + acpmsCurrentPhaseCValueStr + DisplayString, + acpmsVoltageL1L2Value + DisplayString, + acpmsVoltageL2L3Value + DisplayString, + acpmsVoltageL3L1Value + DisplayString, + acpmsAvgFreqValueStr + DisplayString, + acpmsAvgFreqMinStr + DisplayString, + acpmsAvgFreqMaxStr + DisplayString, + acpmsAvgFreqAvgStr + DisplayString, + acpmsAvgFreqInEventState + DisplayString, + acpmsTRPValueStr + DisplayString, + acpmsTRPMinStr + DisplayString, + acpmsTRPMaxStr + DisplayString, + acpmsTRPAvgStr + DisplayString, + acpmsTRPInEventState + DisplayString, + acpmsRPPhaseAValueStr + DisplayString, + acpmsRPPhaseBValueStr + DisplayString, + acpmsRPPhaseCValueStr + DisplayString, + acpmsCombined + DisplayString, + acpmsTPFValueStr + DisplayString, + acpmsTPFMinStr + DisplayString, + acpmsTPFMaxStr + DisplayString, + acpmsTPFAvgStr + DisplayString, + acpmsTPFInEventState + DisplayString, + acpmsPFPhaseAValueStr + DisplayString, + acpmsPFPhaseBValueStr + DisplayString, + acpmsPFPhaseCValueStr + DisplayString, + acpmsTRcPValueStr + DisplayString, + acpmsTRcPMinStr + DisplayString, + acpmsTRcPMaxStr + DisplayString, + acpmsTRcPAvgStr + DisplayString, + acpmsRcPPhaseAValueStr + DisplayString, + acpmsRcPPhaseBValueStr + DisplayString, + acpmsRcPPhaseCValueStr + DisplayString, + acpmsTAPValueStr + DisplayString, + acpmsTAPMinStr + DisplayString, + acpmsTAPMaxStr + DisplayString, + acpmsTAPAvgStr + DisplayString, + acpmsAPPhaseAValueStr + DisplayString, + acpmsAPPhaseBValueStr + DisplayString, + acpmsAPPhaseCValueStr + DisplayString, + acpmsTotalEnergyWh + Integer32, + acpmsTotalEnergyVAR + Integer32, + acpmsTotalEnergyVA + Integer32, + acmpsAvgVoltageAlarmDatetime + DisplayString, + acmpsAvgCurrentAlarmDatetime + DisplayString, + acmpsFreqAlarmDatetime + DisplayString, + acmpsRealPowerAlarmDatetime + DisplayString, + acmpsPowerFactorAlarmDatetime + DisplayString +} + +HVACStatusAsentriaSequence ::= + SEQUENCE { + evHVACStatusAsentriaSequenceIndex + Integer32, + evHVACStatusAsentriaSeqVentTime + DisplayString, + evHVACStatusAsentriaSeqCoolTime + DisplayString, + evHVACStatusAsentriaSeqHeatTime + DisplayString, + evHVACStatusAsentriaSeqIdleTime + DisplayString +} + +HVACStatusAsentriaUnit ::= + SEQUENCE { + evHVACStatusAsentriaUnitIndex + Integer32, + evHVACStatusAsentriaUnitState + DisplayString, + evHVACStatusAsentriaUnitVentTime + DisplayString, + evHVACStatusAsentriaUnitCoolTime + DisplayString, + evHVACStatusAsentriaUnitHeatTime + DisplayString, + evHVACStatusAsentriaUnitIdleTime + DisplayString +} + +HVACStatusAirsysAlarmUnit ::= + SEQUENCE { + evHVACStatusAirsysAlarmUnitIndex + Integer32, + evHVACStatusAirsysAlarmUnitLowPress + DisplayString, + evHVACStatusAirsysAlarmUnitHighPress + DisplayString, + evHVACStatusAirsysAlarmUnitEvapFan + DisplayString, + evHVACStatusAirsysAlarmUnitDirty + DisplayString, + evHVACStatusAirsysAlarmUnitDamper + DisplayString, + evHVACStatusAirsysAlarmUnitSupProbe + DisplayString +} + +HVACStatusAirsysUnit ::= + SEQUENCE { + evHVACStatusAirsysUnitIndex + Integer32, + evHVACStatusAirsysUnitTempSupply + DisplayString, + evHVACStatusAirsysUnitFanspeed + DisplayString, + evHVACStatusAirsysUnitFreeOpening + DisplayString, + evHVACStatusAirsysUnitStatus + DisplayString, + evHVACStatusAirsysUnitLocked + DisplayString, + evHVACStatusAirsysUnitCompressor + DisplayString, + evHVACStatusAirsysUnitHeater + DisplayString, + evHVACStatusAirsysURuntimeSupplyFan + DisplayString, + evHVACStatusAirsysURuntimeCompressor + DisplayString, + evHVACStatusAirsysURuntimeHeat + DisplayString, + evHVACStatusAirsysURuntimeFreeCooling + DisplayString, + evHVACStatusAirsysUCountSupplyFan + DisplayString, + evHVACStatusAirsysUCountCompressor + DisplayString, + evHVACStatusAirsysUCountHeat + DisplayString, + evHVACStatusAirsysUCountFreeCooling + DisplayString +} + +HVACAsentriaSensorList ::= + SEQUENCE { + evHVACAsentriaSensorListIndex + Integer32, + evHVACAsentriaSensorListES + DisplayString, + evHVACAsentriaSensorListPT + Integer32, + evHVACAsentriaSensorListType + DisplayString, + evHVACAsentriaSensorListLoc + DisplayString +} + +HVACAsentriaUnit ::= + SEQUENCE { + evHVACAsentriaUnitIndex + Integer32, + evHVACAsentriaUnitEnable + DisplayString, + evHVACAsentriaUnitFanRelayES + DisplayString, + evHVACAsentriaUnitFanRelayPT + Integer32, + evHVACAsentriaUnitVentRelayES + DisplayString, + evHVACAsentriaUnitVentRelayPT + Integer32, + evHVACAsentriaUnitTimereset + Integer32, + evHVACAsentriaSeqTimereset + Integer32, + evHVACAsentriaUnitStage1CoolES + DisplayString, + evHVACAsentriaUnitStage1CoolPT + Integer32, + evHVACAsentriaUnitStage1HeatES + DisplayString, + evHVACAsentriaUnitStage1HeatPT + Integer32, + evHVACAsentriaUnitStage2CoolES + DisplayString, + evHVACAsentriaUnitStage2CoolPT + Integer32, + evHVACAsentriaUnitStage2HeatES + DisplayString, + evHVACAsentriaUnitStage2HeatPT + Integer32 +} + +HVACAirsysUnit::= + SEQUENCE { + evHVACAirsysUnitIndex + Integer32, + evHVACAirsysULowPEnable + DisplayString, + evHVACAirsysULowPActions + DisplayString, + evHVACAirsysULowPTrapnum + Integer32, + evHVACAirsysULowPClass + DisplayString, + evHVACAirsysULowPNormActions + DisplayString, + evHVACAirsysULowPNormTrapNum + Integer32, + evHVACAirsysULowPNormClass + DisplayString, + evHVACAirsysUHighPEnable + DisplayString, + evHVACAirsysUHighPActions + DisplayString, + evHVACAirsysUHighPTrapnum + Integer32, + evHVACAirsysUHighPClass + DisplayString, + evHVACAirsysUHighPNormActions + DisplayString, + evHVACAirsysUHighPNormTrapNum + Integer32, + evHVACAirsysUHighPNormClass + DisplayString, + evHVACAirsysUEvapFanEnable + DisplayString, + evHVACAirsysUEvapFanActions + DisplayString, + evHVACAirsysUEvapFanTrapnum + Integer32, + evHVACAirsysUEvapFanClass + DisplayString, + evHVACAirsysUEvapFanNormActions + DisplayString, + evHVACAirsysUEvapFanNormTrapNum + Integer32, + evHVACAirsysUEvapFanNormClass + DisplayString, + evHVACAirsysUDirtyEnable + DisplayString, + evHVACAirsysUDirtyActions + DisplayString, + evHVACAirsysUDirtyTrapnum + Integer32, + evHVACAirsysUDirtyClass + DisplayString, + evHVACAirsysUDirtyNormActions + DisplayString, + evHVACAirsysUDirtyNormTrapNum + Integer32, + evHVACAirsysUDirtyNormClass + DisplayString, + evHVACAirsysUInProbeEnable + DisplayString, + evHVACAirsysUInProbeActions + DisplayString, + evHVACAirsysUInProbeTrapnum + Integer32, + evHVACAirsysUInProbeClass + DisplayString, + evHVACAirsysUInProbeNormActions + DisplayString, + evHVACAirsysUInProbeNormTrapNum + Integer32, + evHVACAirsysUInProbeNormClass + DisplayString, + evHVACAirsysUDamperEnable + DisplayString, + evHVACAirsysUDamperActions + DisplayString, + evHVACAirsysUDamperTrapnum + Integer32, + evHVACAirsysUDamperClass + DisplayString, + evHVACAirsysUDamperNormActions + DisplayString, + evHVACAirsysUDamperNormTrapNum + Integer32, + evHVACAirsysUDamperNormClass + DisplayString, + evHVACAirsysUSupProbeEnable + DisplayString, + evHVACAirsysUSupProbeActions + DisplayString, + evHVACAirsysUSupProbeTrapnum + Integer32, + evHVACAirsysUSupProbeClass + DisplayString, + evHVACAirsysUSupProbeNormActions + DisplayString, + evHVACAirsysUSupProbeNormTrapNum + Integer32, + evHVACAirsysUSupProbeNormClass + DisplayString +} + +ScheduleConfig ::= + SEQUENCE { + schedIndex + Integer32, + schedEnable + DisplayString, + schedStart + DisplayString, + schedRepeatMode + DisplayString, + schedRepeatFreq + Integer32, + schedRepeatEndMode + DisplayString, + schedRepeatEndAfter + Integer32, + schedRepeatEndOn + DisplayString, + schedRepeatWeeklySun + DisplayString, + schedRepeatWeeklyMon + DisplayString, + schedRepeatWeeklyTue + DisplayString, + schedRepeatWeeklyWed + DisplayString, + schedRepeatWeeklyThu + DisplayString, + schedRepeatWeeklyFri + DisplayString, + schedRepeatWeeklySat + DisplayString, + schedRepeatMonthlyMode + DisplayString, + schedRepeatMonthlyDates + DisplayString, + schedRepeatMonthlyOnThe + DisplayString, + schedRepeatMonthlyOnDay + DisplayString, + schedRepeatYearlyJan + DisplayString, + schedRepeatYearlyFeb + DisplayString, + schedRepeatYearlyMar + DisplayString, + schedRepeatYearlyApr + DisplayString, + schedRepeatYearlyMay + DisplayString, + schedRepeatYearlyJun + DisplayString, + schedRepeatYearlyJul + DisplayString, + schedRepeatYearlyAug + DisplayString, + schedRepeatYearlySep + DisplayString, + schedRepeatYearlyOct + DisplayString, + schedRepeatYearlyNov + DisplayString, + schedRepeatYearlyDec + DisplayString, + schedRepeatYearlyOnThe + DisplayString, + schedRepeatYearlyOnDay + DisplayString, + schedNextTrigger + DisplayString +} + +FuelSensorConfigGeneral ::= + SEQUENCE { + fsGenIndex + Integer32, + fsGenName + DisplayString, + fsGenSensorType + DisplayString, + fsGenDistanceUnit + DisplayString, + fsGenRawValueTop + DisplayString, + fsGenTopOffset + DisplayString, + fsGenRawValueBottom + DisplayString, + fsGenBottomOffset + DisplayString, + fsGenInputES + Integer32, + fsGenInputPoint + Integer32, + fsGenFilterAveraging + Integer32, + fsGenSysrepEnable + DisplayString, + fsGenSysrepThreshold + DisplayString, + fsGenSysrepLimit + Integer32, + fsGenSysrepPackage + Integer32, + fsGenGroup + DisplayString, + fsGenEnable + DisplayString, + fsGenFuelType + DisplayString +} + +FuelSensorConfigTank ::= + SEQUENCE { + fsTankIndex + Integer32, + fsTankHeight + DisplayString, + fsTankDimA + DisplayString, + fsTankDimB + DisplayString, + fsTankVolume + DisplayString, + fsTankVolumeUnit + DisplayString, + fsTankShape + DisplayString +} + +FuelSensorConfigCustomTankStrapping ::= + SEQUENCE { + fsCustomTankIndexFS + Integer32, + fsCustomTankIndexDatum + Integer32, + fsCustomTankHeight + DisplayString, + fsCustomTankVolume + DisplayString +} + +FuelSensorConfigVolume ::= + SEQUENCE { + fsVolumeIndex + Integer32, + fsVolumeEnable + DisplayString, + fsVolumeDeadband + DisplayString, + fsVolumeVHighValue + DisplayString, + fsVolumeVHighActions + DisplayString, + fsVolumeVHighTrapNum + Integer32, + fsVolumeVHighClass + DisplayString, + fsVolumeHighValue + DisplayString, + fsVolumeHighActions + DisplayString, + fsVolumeHighTrapNum + Integer32, + fsVolumeHighClass + DisplayString, + fsVolumeNormalActions + DisplayString, + fsVolumeNormalTrapNum + Integer32, + fsVolumeNormalClass + DisplayString, + fsVolumeLowValue + DisplayString, + fsVolumeLowActions + DisplayString, + fsVolumeLowTrapNum + Integer32, + fsVolumeLowClass + DisplayString, + fsVolumeVLowValue + DisplayString, + fsVolumeVLowActions + DisplayString, + fsVolumeVLowTrapNum + Integer32, + fsVolumeVLowClass + DisplayString +} + +FuelSensorConfigDisconnect ::= + SEQUENCE { + fsDiscIndex + Integer32, + fsDiscEnable + DisplayString, + fsDiscHighValue + DisplayString, + fsDiscLowValue + DisplayString, + fsDiscActions + DisplayString, + fsDiscTrapNum + Integer32, + fsDiscClass + DisplayString, + fsDiscNormalActions + DisplayString, + fsDiscNormalTrapNum + Integer32, + fsDiscNormalClass + DisplayString +} + +FuelSensorConfigSuddenChange ::= + SEQUENCE { + fsSuddenChangeIndex + Integer32, + fsSuddenChangeEnable + DisplayString, + fsSuddenChangeTime + Integer32, + fsSuddenChangeAmplitude + DisplayString, + fsSuddenChangeActions + DisplayString, + fsSuddenChangeTrapNum + Integer32, + fsSuddenChangeClass + DisplayString +} + +FuelSensorConfigSlowChange ::= + SEQUENCE { + fsSlowChangeIndex + Integer32, + fsSlowChangeEnable + DisplayString, + fsSlowChangeTime + Integer32, + fsSlowChangeAmplitude + DisplayString, + fsSlowChangeActions + DisplayString, + fsSlowChangeTrapNum + Integer32, + fsSlowChangeClass + DisplayString +} + +ACPMConfigGeneral ::= + SEQUENCE { + acpmGenIndex + Integer32, + acpmGenDevice + DisplayString, + acpmGenName + DisplayString, + acpmGenAddress + Integer32, + acpmGenPtRatio + Integer32, + acpmGenCtRatio + Integer32, + acpmGenPowerType + DisplayString, + acpmGenSysrepPackage + Integer32, + acpmGenGroup + DisplayString, + acpmGenEnable + DisplayString +} + +ACPMConfigAvgVoltage ::= + SEQUENCE { + acpmAvgVoltageIndex + Integer32, + acpmAvgVoltageEnable + DisplayString, + acpmAvgVoltageDeadband + DisplayString, + acpmAvgVoltageVHighValue + DisplayString, + acpmAvgVoltageVHighActions + DisplayString, + acpmAvgVoltageVHighTrapNum + Integer32, + acpmAvgVoltageVHighClass + DisplayString, + acpmAvgVoltageHighValue + DisplayString, + acpmAvgVoltageHighActions + DisplayString, + acpmAvgVoltageHighTrapNum + Integer32, + acpmAvgVoltageHighClass + DisplayString, + acpmAvgVoltageNormalActions + DisplayString, + acpmAvgVoltageNormalTrapNum + Integer32, + acpmAvgVoltageNormalClass + DisplayString, + acpmAvgVoltageLowValue + DisplayString, + acpmAvgVoltageLowActions + DisplayString, + acpmAvgVoltageLowTrapNum + Integer32, + acpmAvgVoltageLowClass + DisplayString, + acpmAvgVoltageVLowValue + DisplayString, + acpmAvgVoltageVLowActions + DisplayString, + acpmAvgVoltageVLowTrapNum + Integer32, + acpmAvgVoltageVLowClass + DisplayString, + acpmAvgVoltageSysrepEnable + DisplayString, + acpmAvgVoltageSysrepThreshold + DisplayString, + acpmAvgVoltageSysrepLimit + Integer32 +} + +ACPMConfigAvgCurrent ::= + SEQUENCE { + acpmAvgCurrentIndex + Integer32, + acpmAvgCurrentEnable + DisplayString, + acpmAvgCurrentDeadband + DisplayString, + acpmAvgCurrentVHighValue + DisplayString, + acpmAvgCurrentVHighActions + DisplayString, + acpmAvgCurrentVHighTrapNum + Integer32, + acpmAvgCurrentVHighClass + DisplayString, + acpmAvgCurrentHighValue + DisplayString, + acpmAvgCurrentHighActions + DisplayString, + acpmAvgCurrentHighTrapNum + Integer32, + acpmAvgCurrentHighClass + DisplayString, + acpmAvgCurrentNormalActions + DisplayString, + acpmAvgCurrentNormalTrapNum + Integer32, + acpmAvgCurrentNormalClass + DisplayString, + acpmAvgCurrentLowValue + DisplayString, + acpmAvgCurrentLowActions + DisplayString, + acpmAvgCurrentLowTrapNum + Integer32, + acpmAvgCurrentLowClass + DisplayString, + acpmAvgCurrentVLowValue + DisplayString, + acpmAvgCurrentVLowActions + DisplayString, + acpmAvgCurrentVLowTrapNum + Integer32, + acpmAvgCurrentVLowClass + DisplayString, + acpmAvgCurrentSysrepEnable + DisplayString, + acpmAvgCurrentSysrepThreshold + DisplayString, + acpmAvgCurrentSysrepLimit + Integer32 +} + +ACPMConfigFreq ::= + SEQUENCE { + acpmFreqIndex + Integer32, + acpmFreqEnable + DisplayString, + acpmFreqDeadband + DisplayString, + acpmFreqVHighValue + DisplayString, + acpmFreqVHighActions + DisplayString, + acpmFreqVHighTrapNum + Integer32, + acpmFreqVHighClass + DisplayString, + acpmFreqHighValue + DisplayString, + acpmFreqHighActions + DisplayString, + acpmFreqHighTrapNum + Integer32, + acpmFreqHighClass + DisplayString, + acpmFreqNormalActions + DisplayString, + acpmFreqNormalTrapNum + Integer32, + acpmFreqNormalClass + DisplayString, + acpmFreqLowValue + DisplayString, + acpmFreqLowActions + DisplayString, + acpmFreqLowTrapNum + Integer32, + acpmFreqLowClass + DisplayString, + acpmFreqVLowValue + DisplayString, + acpmFreqVLowActions + DisplayString, + acpmFreqVLowTrapNum + Integer32, + acpmFreqVLowClass + DisplayString, + acpmFreqSysrepEnable + DisplayString, + acpmFreqSysrepThreshold + DisplayString, + acpmFreqSysrepLimit + Integer32 +} + +ACPMConfigTRP ::= + SEQUENCE { + acpmTRPIndex + Integer32, + acpmTRPEnable + DisplayString, + acpmTRPDeadband + DisplayString, + acpmTRPVHighValue + DisplayString, + acpmTRPVHighActions + DisplayString, + acpmTRPVHighTrapNum + Integer32, + acpmTRPVHighClass + DisplayString, + acpmTRPHighValue + DisplayString, + acpmTRPHighActions + DisplayString, + acpmTRPHighTrapNum + Integer32, + acpmTRPHighClass + DisplayString, + acpmTRPNormalActions + DisplayString, + acpmTRPNormalTrapNum + Integer32, + acpmTRPNormalClass + DisplayString, + acpmTRPLowValue + DisplayString, + acpmTRPLowActions + DisplayString, + acpmTRPLowTrapNum + Integer32, + acpmTRPLowClass + DisplayString, + acpmTRPVLowValue + DisplayString, + acpmTRPVLowActions + DisplayString, + acpmTRPVLowTrapNum + Integer32, + acpmTRPVLowClass + DisplayString, + acpmTRPSysrepEnable + DisplayString, + acpmTRPSysrepThreshold + DisplayString, + acpmTRPSysrepLimit + Integer32 +} + +ACPMConfigDisconnect ::= + SEQUENCE { + acpmDisconnectIndex + Integer32, + acpmDisconnectEnable + DisplayString, + acpmDisconnectActions + DisplayString, + acpmDisconnectTrapNum + Integer32, + acpmDisconnectClass + DisplayString, + acpmDisconnectNormalActions + DisplayString, + acpmDisconnectNormalTrapNum + Integer32, + acpmDisconnectNormalClass + DisplayString +} + +ACPMConfigTotalPowerFactor ::= + SEQUENCE { + acpmTPFIndex + Integer32, + acpmTPFEnable + DisplayString, + acpmTPFDeadband + DisplayString, + acpmTPFNormalActions + DisplayString, + acpmTPFNormalTrapNum + Integer32, + acpmTPFNormalClass + DisplayString, + acpmTPFLowValue + DisplayString, + acpmTPFLowActions + DisplayString, + acpmTPFLowTrapNum + Integer32, + acpmTPFLowClass + DisplayString, + acpmTPFVLowValue + DisplayString, + acpmTPFVLowActions + DisplayString, + acpmTPFVLowTrapNum + Integer32, + acpmTPFVLowClass + DisplayString, + acpmTPFSysrepEnable + DisplayString, + acpmTPFSysrepThreshold + DisplayString, + acpmTPFSysrepLimit + Integer32 +} + +WebXMLProxyDeviceConfig ::= + SEQUENCE { + wxpDeviceIndex + Integer32, + wxpDeviceEnable + DisplayString, + wxpDeviceIPAddress + IpAddress, + wxpDevicePort + Integer32, + wxpDeviceRemoteFile + DisplayString, + wxpDeviceLocalFile + DisplayString, + wxpDeviceTimeout + Integer32, + wxpDeviceTimestamp + DisplayString +} + +EthernetExpansionCardConfig ::= + SEQUENCE { + ethExpanCardIndex + Integer32, + ethExpanCardMAC + DisplayString +} + + +AccessControlDevice ::= + SEQUENCE { + acdIndex + Integer32, + acdEnable + DisplayString, + acdName + DisplayString, + acdReader + DisplayString, + acdWiegandES + Integer32, + acdWiegandPoint + Integer32, + acdRelayType + DisplayString, + acdRelayES + Integer32, + acdRelayPoint + Integer32, + acdOpenTime + Integer32, + acdUserGroup + Integer32 +} + +AccessControlUser ::= + SEQUENCE { + acuIndexUserGroup + Integer32, + acuIndexUser + Integer32, + acuEnable + DisplayString, + acuName + DisplayString, + acuSn + DisplayString, + acuSunBegin + DisplayString, + acuSunEnd + DisplayString, + acuMonBegin + DisplayString, + acuMonEnd + DisplayString, + acuTueBegin + DisplayString, + acuTueEnd + DisplayString, + acuWedBegin + DisplayString, + acuWedEnd + DisplayString, + acuThuBegin + DisplayString, + acuThuEnd + DisplayString, + acuFriBegin + DisplayString, + acuFriEnd + DisplayString, + acuSatBegin + DisplayString, + acuSatEnd + DisplayString +} + +TelemetryPoint ::= + SEQUENCE { + telemetryPointIndex + Integer32, + telemetryPointName + DisplayString, + telemetryPointKey + DisplayString, + telemetryPointType + DisplayString, + telemetryPointClass + DisplayString, + telemetryPointDeadband + DisplayString, + telemetryPointShortcode + DisplayString +} + + +SiteSecIntrusion ::= + SEQUENCE { + siteSecEnable + DisplayString, + siteSecDisarmed + DisplayString, + siteSecName + DisplayString, + siteSecState + DisplayString, + siteSecSensorES + Integer32, + siteSecSensorPoint + Integer32, + siteSecIntrusionThreshold + Integer32, + siteSecReader + DisplayString, + siteSecReaderThreshold + Integer32, + siteSecButtonEnable + DisplayString, + siteSecButtonES + Integer32, + siteSecButtonPoint + Integer32, + siteSecButtonType + DisplayString, + siteSecButtonThresholdArm + Integer32, + siteSecButtonThresholdDisarm + Integer32, + siteSecSirenEnable + DisplayString, + siteSecSirenES + Integer32, + siteSecSirenPoint + Integer32, + siteSecRearmDelay + Integer32 +} + +SiteSecMotion ::= + SEQUENCE { + + siteSecMotionES + Integer32, + siteSecMotionPoint + Integer32, + siteSecMotionEnable + DisplayString, + siteSecMotionName + DisplayString, + siteSecMotionThresholdRearm + Integer32 +} + +SiteSecDoorAjar ::= + SEQUENCE { + siteSecDoorAjarEnable + DisplayString, + siteSecDoorAjarName + DisplayString, + siteSecDoorAjarES + Integer32, + siteSecDoorAjarPoint + Integer32, + siteSecDoorAjarThresholdNormal + Integer32, + siteSecDoorAjarThresholdExtraTime + Integer32 +} + + + + +--*************************************************************************************** +--TRAP DEFINITIONS +--*************************************************************************************** + +s550StockSensorUnresponsiveTrap NOTIFICATION-TYPE + OBJECTS { siteName, stockTrapString, trapTypeString } + STATUS current + DESCRIPTION + "A stock unresponsive trap is issued when a sensor is unresponsive." + ::= { s550notifications 50 } + +s550notificationsStockContactClosureTrap NOTIFICATION-TYPE + OBJECTS { siteName, stockTrapString, trapTypeString } + STATUS current + DESCRIPTION + "A stock contact closure trap is issued when a contact closure + event happens." + ::= { s550notifications 110 } + +s550notificationsStockTempTrap NOTIFICATION-TYPE + OBJECTS { siteName, stockTrapString, trapTypeString } + STATUS current + DESCRIPTION + "A stock temperature trap is issued when a temperature event + happens." + ::= { s550notifications 120 } + +s550notificationsStockHumidityTrap NOTIFICATION-TYPE + OBJECTS { siteName, stockTrapString, trapTypeString } + STATUS current + DESCRIPTION + "A stock humidity trap is issued when a humidity event + happens." + ::= { s550notifications 130 } + +s550notificationsStockAnalogTrap NOTIFICATION-TYPE + OBJECTS { siteName, stockTrapString, trapTypeString } + STATUS current + DESCRIPTION + "A stock analog trap is issued when an analog sensor event + happens." + ::= { s550notifications 140 } + +s550notificationsStockOutputTrap NOTIFICATION-TYPE + OBJECTS { siteName, stockTrapString, trapTypeString } + STATUS current + DESCRIPTION + "A stock output trap is issued when an output event + happens. That is, depending on the configuration, + when an output changes state for any reason, this + trap will be sent." + ::= { s550notifications 150 } + +s550StockPDCurrentTrap NOTIFICATION-TYPE + OBJECTS { siteName, stockTrapString, trapTypeString } + STATUS current + DESCRIPTION + "A stock analog trap is issued when a power distribution + current event happens." + ::= { s550notifications 180 } + +s550StockPDVoltageTrap NOTIFICATION-TYPE + OBJECTS { siteName, stockTrapString, trapTypeString } + STATUS current + DESCRIPTION + "A stock analog trap is issued when a power distribution + voltage event happens." + ::= { s550notifications 190 } + +s550StockPDFuseTrap NOTIFICATION-TYPE + OBJECTS { siteName, stockTrapString, trapTypeString } + STATUS current + DESCRIPTION + "A stock analog trap is issued when a power distribution + fuse event happens." + ::= { s550notifications 210 } + +s550notificationsStockDbasePfullTrap NOTIFICATION-TYPE + OBJECTS { siteName, stockTrapString, trapTypeString } + STATUS current + DESCRIPTION + "The stock database percent full trap is issued + when the database size surpasses the threshold." + ::= { s550notifications 501 } + +s550notificationsStockDataAlarmTrap NOTIFICATION-TYPE + OBJECTS { siteName, stockTrapString, trapTypeString } + STATUS current + DESCRIPTION + "The stock data alarm trap is issued when a + data alarm happens." + ::= { s550notifications 503 } + +s550notificationsStockNoDataAlarmTrap NOTIFICATION-TYPE + OBJECTS { siteName, stockTrapString, trapTypeString } + STATUS current + DESCRIPTION + "The stock no-data alarm trap is issued when + the unit has received no data for a configured + interval within a configured schedule." + ::= { s550notifications 505 } + +s550notificationsStockSchedTrap NOTIFICATION-TYPE + OBJECTS { siteName, stockTrapString, trapTypeString } + STATUS current + DESCRIPTION + "The stock scheduled alarm trap is issued + when the current time reaches the scheduled + alarm time." + ::= { s550notifications 506 } + +s550notificationsStockImmediateTrap NOTIFICATION-TYPE + OBJECTS { siteName, stockTrapString, trapTypeString } + STATUS current + DESCRIPTION + "The stock immediate alarm trap is issued + when the user enters the DOTRAP command." + ::= { s550notifications 507 } + +s550StockBattRunningTrap NOTIFICATION-TYPE + OBJECTS { siteName, liBattPercentCharge, liBattRunning } + STATUS current + DESCRIPTION + "The stock trap issued when the battery power state change. + Gives the unit name, percentage charge of the battery and + if unit is running on battery backup (0 is False and 1 is True)" + ::= { s550notifications 508 } + +s550notificationsStockCTSTrap NOTIFICATION-TYPE + OBJECTS { siteName, stockTrapString, trapTypeString } + STATUS current + DESCRIPTION + "A stock CTS trap is issued when an RS-232 CTS event + happens." + ::= { s550notifications 510 } + +s550notificationsCPEDownTrap NOTIFICATION-TYPE + OBJECTS { siteName, stockTrapString, trapTypeString } + STATUS current + DESCRIPTION + "A stock CPE Down trap is issued when a CPE Down event + happens." + ::= { s550notifications 511 } + +s550notificationsFuelSensorDisconnectTrap NOTIFICATION-TYPE + OBJECTS { siteName, stockTrapString, trapTypeString } + STATUS current + DESCRIPTION + "A stock Fuel Sensor Disconnect trap is issued when a Fuel + Sensor Disconnect or Connect (Return to Normal) event happens." + ::= { s550notifications 515 } + +s550notificationsFuelSensorVolumeTrap NOTIFICATION-TYPE + OBJECTS { siteName, stockTrapString, trapTypeString } + STATUS current + DESCRIPTION + "A stock Fuel Sensor Volume trap is issued when a Fuel + Sensor Volume event happens" + ::= { s550notifications 519 } + +s550notificationsACPowerMonitorAvgVoltageTrap NOTIFICATION-TYPE + OBJECTS { siteName, stockTrapString, trapTypeString } + STATUS current + DESCRIPTION + "A stock AC power monitor average voltage trap is issued when an + AC power monitor average voltage event happens." + ::= { s550notifications 520 } + +s550notificationsACPowerMonitorAvgCurrentTrap NOTIFICATION-TYPE + OBJECTS { siteName, stockTrapString, trapTypeString } + STATUS current + DESCRIPTION + "A stock AC power monitor average current trap is issued when an + AC power monitor average current event happens." + ::= { s550notifications 521 } + +s550notificationsACPowerMonitorFrequencyTrap NOTIFICATION-TYPE + OBJECTS { siteName, stockTrapString, trapTypeString } + STATUS current + DESCRIPTION + "A stock AC power monitor frequency trap is issued when an + AC power monitor frequency event happens." + ::= { s550notifications 522 } + +s550notificationsACPowerMonitorTRPTrap NOTIFICATION-TYPE + OBJECTS { siteName, stockTrapString, trapTypeString } + STATUS current + DESCRIPTION + "A stock AC power monitor TRP (total real power) trap is issued + when an AC power monitor TRP event happens." + ::= { s550notifications 523 } + +s550notificationsACPowerMonitorDisconnectTrap NOTIFICATION-TYPE + OBJECTS { siteName, stockTrapString, trapTypeString } + STATUS current + DESCRIPTION + "A stock AC power monitor disconnect trap is issued + when an AC power monitor disconnect event happens." + ::= { s550notifications 524 } + +s550notificationsStockScriptTrap NOTIFICATION-TYPE + OBJECTS { siteName, stockTrapString, trapTypeString } + STATUS current + DESCRIPTION + "A stock script trap is issued when a script triggers + an event via a_lib.PostEvent() called with no trap + number (or this trap number) specified." + ::= { s550notifications 526 } + +s550notificationsFuelSensorVolumeSuddenChangeTrap NOTIFICATION-TYPE + OBJECTS { siteName, stockTrapString, trapTypeString } + STATUS current + DESCRIPTION + "A stock Fuel Sensor Volume Sudden Change trap is issued + when a Fuel Sensor Volume Sudden Change event happens" + ::= { s550notifications 527 } + +s550notificationsFuelSensorVolumeSlowChangeTrap NOTIFICATION-TYPE + OBJECTS { siteName, stockTrapString, trapTypeString } + STATUS current + DESCRIPTION + "A stock Fuel Sensor Volume Slow Change trap is issued + when a Fuel Sensor Volume Slow Change event happens" + ::= { s550notifications 528 } + +s550notificationsCameraTrap NOTIFICATION-TYPE + OBJECTS { siteName, stockTrapString, trapTypeString } + STATUS current + DESCRIPTION + "A stock camera trap is issued when a camera event happens." + ::= { s550notifications 539 } + +s550notificationsGeneratorNonStartTrap NOTIFICATION-TYPE + OBJECTS { siteName, stockTrapString, trapTypeString } + STATUS current + DESCRIPTION + "A stock Generator Non-start trap is issued + when the unit commands the generator to start as + part of the generator exercising feature, and the + generator fails to register as started after 30 + seconds (as detected by CC generator running + detection)." + ::= { s550notifications 536 } + +s550notificationsACTotalPowerFactorTrap NOTIFICATION-TYPE + OBJECTS { siteName, stockTrapString, trapTypeString } + STATUS current + DESCRIPTION + "A stock AC power monitor total power factor trap is issued + when an AC power monitor total power factor event happens." + ::= { s550notifications 540 } + +s550notificationsResetTrap NOTIFICATION-TYPE + OBJECTS { siteName, stockTrapString, trapTypeString } + STATUS current + DESCRIPTION + "A stock reset trap is issued when a reset event happens." + ::= { s550notifications 543 } + +s550notificationHVACAsentriaControlTrap NOTIFICATION-TYPE + OBJECTS { siteName, stockTrapString, trapTypeString } + STATUS current + DESCRIPTION + "A stock HVAC Asentria Control trap is issued when an issue with + temperature, humidity, fire detection and other HVAC related + event happens." + ::= { s550notifications 545 } + +s550notificationAccessControlTrap NOTIFICATION-TYPE + OBJECTS { siteName, stockTrapString, trapTypeString } + STATUS current + DESCRIPTION + "A stock access control trap is issued when an access control + device management event happens." + ::= { s550notifications 547 } + +s550notificationHVACAirsysControlTrap NOTIFICATION-TYPE + OBJECTS { siteName, stockTrapString, trapTypeString } + STATUS current + DESCRIPTION + "A stock HVAC Airsys Control trap is issued when an issue + related to alarm conditions for the Airsys HVAC system + event happens." + ::= { s550notifications 548 } + +s550notificationsUserTrap1000 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1000." + ::= { s550notifications 1000 } + +s550notificationsUserTrap1001 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1001." + ::= { s550notifications 1001 } + +s550notificationsUserTrap1002 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1002." + ::= { s550notifications 1002 } + +s550notificationsUserTrap1003 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1003." + ::= { s550notifications 1003 } + +s550notificationsUserTrap1004 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1004." + ::= { s550notifications 1004 } + +s550notificationsUserTrap1005 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1005." + ::= { s550notifications 1005 } + +s550notificationsUserTrap1006 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1006." + ::= { s550notifications 1006 } + +s550notificationsUserTrap1007 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1007." + ::= { s550notifications 1007 } + +s550notificationsUserTrap1008 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1008." + ::= { s550notifications 1008 } + +s550notificationsUserTrap1009 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1009." + ::= { s550notifications 1009 } + +s550notificationsUserTrap1010 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1010." + ::= { s550notifications 1010 } + +s550notificationsUserTrap1011 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1011." + ::= { s550notifications 1011 } + +s550notificationsUserTrap1012 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1012." + ::= { s550notifications 1012 } + +s550notificationsUserTrap1013 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1013." + ::= { s550notifications 1013 } + +s550notificationsUserTrap1014 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1014." + ::= { s550notifications 1014 } + +s550notificationsUserTrap1015 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1015." + ::= { s550notifications 1015 } + +s550notificationsUserTrap1016 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1016." + ::= { s550notifications 1016 } + +s550notificationsUserTrap1017 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1017." + ::= { s550notifications 1017 } + +s550notificationsUserTrap1018 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1018." + ::= { s550notifications 1018 } + +s550notificationsUserTrap1019 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1019." + ::= { s550notifications 1019 } + +s550notificationsUserTrap1020 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1020." + ::= { s550notifications 1020 } + +s550notificationsUserTrap1021 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1021." + ::= { s550notifications 1021 } + +s550notificationsUserTrap1022 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1022." + ::= { s550notifications 1022 } + +s550notificationsUserTrap1023 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1023." + ::= { s550notifications 1023 } + +s550notificationsUserTrap1024 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1024." + ::= { s550notifications 1024 } + +s550notificationsUserTrap1025 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1025." + ::= { s550notifications 1025 } + +s550notificationsUserTrap1026 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1026." + ::= { s550notifications 1026 } + +s550notificationsUserTrap1027 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1027." + ::= { s550notifications 1027 } + +s550notificationsUserTrap1028 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1028." + ::= { s550notifications 1028 } + +s550notificationsUserTrap1029 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1029." + ::= { s550notifications 1029 } + +s550notificationsUserTrap1030 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1030." + ::= { s550notifications 1030 } + +s550notificationsUserTrap1031 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1031." + ::= { s550notifications 1031 } + +s550notificationsUserTrap1032 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1032." + ::= { s550notifications 1032 } + +s550notificationsUserTrap1033 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1033." + ::= { s550notifications 1033 } + +s550notificationsUserTrap1034 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1034." + ::= { s550notifications 1034 } + +s550notificationsUserTrap1035 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1035." + ::= { s550notifications 1035 } + +s550notificationsUserTrap1036 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1036." + ::= { s550notifications 1036 } + +s550notificationsUserTrap1037 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1037." + ::= { s550notifications 1037 } + +s550notificationsUserTrap1038 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1038." + ::= { s550notifications 1038 } + +s550notificationsUserTrap1039 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1039." + ::= { s550notifications 1039 } + +s550notificationsUserTrap1040 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1040." + ::= { s550notifications 1040 } + +s550notificationsUserTrap1041 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1041." + ::= { s550notifications 1041 } + +s550notificationsUserTrap1042 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1042." + ::= { s550notifications 1042 } + +s550notificationsUserTrap1043 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1043." + ::= { s550notifications 1043 } + +s550notificationsUserTrap1044 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1044." + ::= { s550notifications 1044 } + +s550notificationsUserTrap1045 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1045." + ::= { s550notifications 1045 } + +s550notificationsUserTrap1046 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1046." + ::= { s550notifications 1046 } + +s550notificationsUserTrap1047 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1047." + ::= { s550notifications 1047 } + +s550notificationsUserTrap1048 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1048." + ::= { s550notifications 1048 } + +s550notificationsUserTrap1049 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1049." + ::= { s550notifications 1049 } + +s550notificationsUserTrap1050 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1050." + ::= { s550notifications 1050 } + +s550notificationsUserTrap1051 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1051." + ::= { s550notifications 1051 } + +s550notificationsUserTrap1052 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1052." + ::= { s550notifications 1052 } + +s550notificationsUserTrap1053 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1053." + ::= { s550notifications 1053 } + +s550notificationsUserTrap1054 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1054." + ::= { s550notifications 1054 } + +s550notificationsUserTrap1055 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1055." + ::= { s550notifications 1055 } + +s550notificationsUserTrap1056 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1056." + ::= { s550notifications 1056 } + +s550notificationsUserTrap1057 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1057." + ::= { s550notifications 1057 } + +s550notificationsUserTrap1058 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1058." + ::= { s550notifications 1058 } + +s550notificationsUserTrap1059 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1059." + ::= { s550notifications 1059 } + +s550notificationsUserTrap1060 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1060." + ::= { s550notifications 1060 } + +s550notificationsUserTrap1061 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1061." + ::= { s550notifications 1061 } + +s550notificationsUserTrap1062 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1062." + ::= { s550notifications 1062 } + +s550notificationsUserTrap1063 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1063." + ::= { s550notifications 1063 } + +s550notificationsUserTrap1064 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1064." + ::= { s550notifications 1064 } + +s550notificationsUserTrap1065 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1065." + ::= { s550notifications 1065 } + +s550notificationsUserTrap1066 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1066." + ::= { s550notifications 1066 } + +s550notificationsUserTrap1067 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1067." + ::= { s550notifications 1067 } + +s550notificationsUserTrap1068 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1068." + ::= { s550notifications 1068 } + +s550notificationsUserTrap1069 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1069." + ::= { s550notifications 1069 } + +s550notificationsUserTrap1070 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1070." + ::= { s550notifications 1070 } + +s550notificationsUserTrap1071 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1071." + ::= { s550notifications 1071 } + +s550notificationsUserTrap1072 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1072." + ::= { s550notifications 1072 } + +s550notificationsUserTrap1073 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1073." + ::= { s550notifications 1073 } + +s550notificationsUserTrap1074 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1074." + ::= { s550notifications 1074 } + +s550notificationsUserTrap1075 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1075." + ::= { s550notifications 1075 } + +s550notificationsUserTrap1076 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1076." + ::= { s550notifications 1076 } + +s550notificationsUserTrap1077 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1077." + ::= { s550notifications 1077 } + +s550notificationsUserTrap1078 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1078." + ::= { s550notifications 1078 } + +s550notificationsUserTrap1079 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1079." + ::= { s550notifications 1079 } + +s550notificationsUserTrap1080 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1080." + ::= { s550notifications 1080 } + +s550notificationsUserTrap1081 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1081." + ::= { s550notifications 1081 } + +s550notificationsUserTrap1082 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1082." + ::= { s550notifications 1082 } + +s550notificationsUserTrap1083 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1083." + ::= { s550notifications 1083 } + +s550notificationsUserTrap1084 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1084." + ::= { s550notifications 1084 } + +s550notificationsUserTrap1085 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1085." + ::= { s550notifications 1085 } + +s550notificationsUserTrap1086 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1086." + ::= { s550notifications 1086 } + +s550notificationsUserTrap1087 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1087." + ::= { s550notifications 1087 } + +s550notificationsUserTrap1088 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1088." + ::= { s550notifications 1088 } + +s550notificationsUserTrap1089 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1089." + ::= { s550notifications 1089 } + +s550notificationsUserTrap1090 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1090." + ::= { s550notifications 1090 } + +s550notificationsUserTrap1091 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1091." + ::= { s550notifications 1091 } + +s550notificationsUserTrap1092 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1092." + ::= { s550notifications 1092 } + +s550notificationsUserTrap1093 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1093." + ::= { s550notifications 1093 } + +s550notificationsUserTrap1094 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1094." + ::= { s550notifications 1094 } + +s550notificationsUserTrap1095 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1095." + ::= { s550notifications 1095 } + +s550notificationsUserTrap1096 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1096." + ::= { s550notifications 1096 } + +s550notificationsUserTrap1097 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1097." + ::= { s550notifications 1097 } + +s550notificationsUserTrap1098 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1098." + ::= { s550notifications 1098 } + +s550notificationsUserTrap1099 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1099." + ::= { s550notifications 1099 } + +s550notificationsUserTrap1100 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1100." + ::= { s550notifications 1100 } + +s550notificationsUserTrap1101 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1101." + ::= { s550notifications 1101 } + +s550notificationsUserTrap1102 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1102." + ::= { s550notifications 1102 } + +s550notificationsUserTrap1103 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1103." + ::= { s550notifications 1103 } + +s550notificationsUserTrap1104 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1104." + ::= { s550notifications 1104 } + +s550notificationsUserTrap1105 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1105." + ::= { s550notifications 1105 } + +s550notificationsUserTrap1106 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1106." + ::= { s550notifications 1106 } + +s550notificationsUserTrap1107 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1107." + ::= { s550notifications 1107 } + +s550notificationsUserTrap1108 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1108." + ::= { s550notifications 1108 } + +s550notificationsUserTrap1109 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1109." + ::= { s550notifications 1109 } + +s550notificationsUserTrap1110 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1110." + ::= { s550notifications 1110 } + +s550notificationsUserTrap1111 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1111." + ::= { s550notifications 1111 } + +s550notificationsUserTrap1112 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1112." + ::= { s550notifications 1112 } + +s550notificationsUserTrap1113 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1113." + ::= { s550notifications 1113 } + +s550notificationsUserTrap1114 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1114." + ::= { s550notifications 1114 } + +s550notificationsUserTrap1115 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1115." + ::= { s550notifications 1115 } + +s550notificationsUserTrap1116 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1116." + ::= { s550notifications 1116 } + +s550notificationsUserTrap1117 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1117." + ::= { s550notifications 1117 } + +s550notificationsUserTrap1118 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1118." + ::= { s550notifications 1118 } + +s550notificationsUserTrap1119 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1119." + ::= { s550notifications 1119 } + +s550notificationsUserTrap1120 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1120." + ::= { s550notifications 1120 } + +s550notificationsUserTrap1121 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1121." + ::= { s550notifications 1121 } + +s550notificationsUserTrap1122 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1122." + ::= { s550notifications 1122 } + +s550notificationsUserTrap1123 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1123." + ::= { s550notifications 1123 } + +s550notificationsUserTrap1124 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1124." + ::= { s550notifications 1124 } + +s550notificationsUserTrap1125 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1125." + ::= { s550notifications 1125 } + +s550notificationsUserTrap1126 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1126." + ::= { s550notifications 1126 } + +s550notificationsUserTrap1127 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1127." + ::= { s550notifications 1127 } + +s550notificationsUserTrap1128 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1128." + ::= { s550notifications 1128 } + +s550notificationsUserTrap1129 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1129." + ::= { s550notifications 1129 } + +s550notificationsUserTrap1130 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1130." + ::= { s550notifications 1130 } + +s550notificationsUserTrap1131 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1131." + ::= { s550notifications 1131 } + +s550notificationsUserTrap1132 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1132." + ::= { s550notifications 1132 } + +s550notificationsUserTrap1133 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1133." + ::= { s550notifications 1133 } + +s550notificationsUserTrap1134 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1134." + ::= { s550notifications 1134 } + +s550notificationsUserTrap1135 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1135." + ::= { s550notifications 1135 } + +s550notificationsUserTrap1136 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1136." + ::= { s550notifications 1136 } + +s550notificationsUserTrap1137 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1137." + ::= { s550notifications 1137 } + +s550notificationsUserTrap1138 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1138." + ::= { s550notifications 1138 } + +s550notificationsUserTrap1139 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1139." + ::= { s550notifications 1139 } + +s550notificationsUserTrap1140 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1140." + ::= { s550notifications 1140 } + +s550notificationsUserTrap1141 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1141." + ::= { s550notifications 1141 } + +s550notificationsUserTrap1142 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1142." + ::= { s550notifications 1142 } + +s550notificationsUserTrap1143 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1143." + ::= { s550notifications 1143 } + +s550notificationsUserTrap1144 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1144." + ::= { s550notifications 1144 } + +s550notificationsUserTrap1145 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1145." + ::= { s550notifications 1145 } + +s550notificationsUserTrap1146 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1146." + ::= { s550notifications 1146 } + +s550notificationsUserTrap1147 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1147." + ::= { s550notifications 1147 } + +s550notificationsUserTrap1148 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1148." + ::= { s550notifications 1148 } + +s550notificationsUserTrap1149 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1149." + ::= { s550notifications 1149 } + +s550notificationsUserTrap1150 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1150." + ::= { s550notifications 1150 } + +s550notificationsUserTrap1151 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1151." + ::= { s550notifications 1151 } + +s550notificationsUserTrap1152 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1152." + ::= { s550notifications 1152 } + +s550notificationsUserTrap1153 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1153." + ::= { s550notifications 1153 } + +s550notificationsUserTrap1154 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1154." + ::= { s550notifications 1154 } + +s550notificationsUserTrap1155 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1155." + ::= { s550notifications 1155 } + +s550notificationsUserTrap1156 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1156." + ::= { s550notifications 1156 } + +s550notificationsUserTrap1157 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1157." + ::= { s550notifications 1157 } + +s550notificationsUserTrap1158 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1158." + ::= { s550notifications 1158 } + +s550notificationsUserTrap1159 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1159." + ::= { s550notifications 1159 } + +s550notificationsUserTrap1160 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1160." + ::= { s550notifications 1160 } + +s550notificationsUserTrap1161 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1161." + ::= { s550notifications 1161 } + +s550notificationsUserTrap1162 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1162." + ::= { s550notifications 1162 } + +s550notificationsUserTrap1163 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1163." + ::= { s550notifications 1163 } + +s550notificationsUserTrap1164 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1164." + ::= { s550notifications 1164 } + +s550notificationsUserTrap1165 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1165." + ::= { s550notifications 1165 } + +s550notificationsUserTrap1166 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1166." + ::= { s550notifications 1166 } + +s550notificationsUserTrap1167 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1167." + ::= { s550notifications 1167 } + +s550notificationsUserTrap1168 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1168." + ::= { s550notifications 1168 } + +s550notificationsUserTrap1169 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1169." + ::= { s550notifications 1169 } + +s550notificationsUserTrap1170 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1170." + ::= { s550notifications 1170 } + +s550notificationsUserTrap1171 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1171." + ::= { s550notifications 1171 } + +s550notificationsUserTrap1172 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1172." + ::= { s550notifications 1172 } + +s550notificationsUserTrap1173 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1173." + ::= { s550notifications 1173 } + +s550notificationsUserTrap1174 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1174." + ::= { s550notifications 1174 } + +s550notificationsUserTrap1175 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1175." + ::= { s550notifications 1175 } + +s550notificationsUserTrap1176 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1176." + ::= { s550notifications 1176 } + +s550notificationsUserTrap1177 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1177." + ::= { s550notifications 1177 } + +s550notificationsUserTrap1178 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1178." + ::= { s550notifications 1178 } + +s550notificationsUserTrap1179 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1179." + ::= { s550notifications 1179 } + +s550notificationsUserTrap1180 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1180." + ::= { s550notifications 1180 } + +s550notificationsUserTrap1181 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1181." + ::= { s550notifications 1181 } + +s550notificationsUserTrap1182 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1182." + ::= { s550notifications 1182 } + +s550notificationsUserTrap1183 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1183." + ::= { s550notifications 1183 } + +s550notificationsUserTrap1184 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1184." + ::= { s550notifications 1184 } + +s550notificationsUserTrap1185 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1185." + ::= { s550notifications 1185 } + +s550notificationsUserTrap1186 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1186." + ::= { s550notifications 1186 } + +s550notificationsUserTrap1187 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1187." + ::= { s550notifications 1187 } + +s550notificationsUserTrap1188 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1188." + ::= { s550notifications 1188 } + +s550notificationsUserTrap1189 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1189." + ::= { s550notifications 1189 } + +s550notificationsUserTrap1190 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1190." + ::= { s550notifications 1190 } + +s550notificationsUserTrap1191 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1191." + ::= { s550notifications 1191 } + +s550notificationsUserTrap1192 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1192." + ::= { s550notifications 1192 } + +s550notificationsUserTrap1193 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1193." + ::= { s550notifications 1193 } + +s550notificationsUserTrap1194 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1194." + ::= { s550notifications 1194 } + +s550notificationsUserTrap1195 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1195." + ::= { s550notifications 1195 } + +s550notificationsUserTrap1196 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1196." + ::= { s550notifications 1196 } + +s550notificationsUserTrap1197 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1197." + ::= { s550notifications 1197 } + +s550notificationsUserTrap1198 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1198." + ::= { s550notifications 1198 } + +s550notificationsUserTrap1199 NOTIFICATION-TYPE + OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, + trapEventTypeName, esIndexPoint, esPointName, esID, + clock, trapIncludedValue, trapIncludedString, + trapEventClassNumber, trapEventClassName } + STATUS current + DESCRIPTION + "This user-defined trap is issued when an event happens that causes a + trap with specific trap type 1199." + ::= { s550notifications 1199 } + +END |