diff --git a/MIBS/audiocodes/AC-PMSS7-MIB b/MIBS/audiocodes/AC-PMSS7-MIB new file mode 100644 index 0000000..fef2f3e --- /dev/null +++ b/MIBS/audiocodes/AC-PMSS7-MIB @@ -0,0 +1,2835 @@ +
+AC-PM-SS7-MIB DEFINITIONS ::= BEGIN
+
+
+ IMPORTS
+
+
+ OBJECT-TYPE,
+ MODULE-IDENTITY FROM SNMPv2-SMI
+ TAddress,
+ DisplayString,
+ DateAndTime, TEXTUAL-CONVENTION FROM SNMPv2-TC
+ IpAddress FROM RFC1155-SMI
+ Unsigned32,
+ Integer32,
+ enterprises FROM SNMPv2-SMI
+ SnmpAdminString FROM SNMP-FRAMEWORK-MIB
+ audioCodes,
+ acRegistrations,
+ acGeneric,
+ acProducts,acBoardMibs,acPerformance FROM AUDIOCODES-TYPES-MIB;
+
+
+acPMSS7 MODULE-IDENTITY
+ LAST-UPDATED "200909231811Z" --Wednesday, September 23, 2009
+ ORGANIZATION "AudioCodes Ltd"
+ CONTACT-INFO
+ "Postal: Support
+ AudioCodes LTD
+ 1 Hayarden Street
+ Airport City
+ Lod, ISRAEL 70151
+ Tel: 972-3-9764000
+ Fax: 972-3-9764040
+ Email: support@audiocodes.com
+ Web: www.audiocodes.com"
+
+
+ DESCRIPTION
+ "The AC-PM-SS7 MIB offers performance monitoring
+For the SS7 related elements in Audiocodes' devices.
+The Configuration sub-tree is for configuring the interval
+Period length for the entire AC-PM-SS7 MIB, and the
+different tables' thresholds.
+The Data sub-tree presents the tables of monitored
+elements.
+
+Note - for the entire MIB the value (-1) means the value
+Asked for is either not supported or currently not relevant
+(this is for when values asked for are for intervals not yet
+recorded."
+
+
+
+ ::= {acPerformance 13}
+
+
+
+
+
+
+
+
+ acPMSS7Configuration OBJECT IDENTIFIER ::= {acPMSS7 1}
+
+
+ acPMSS7ConfigurationPeriodLength OBJECT-TYPE
+ SYNTAX Unsigned32 (0..894780)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Length of monitoring intervals for entire MIB. Time is in minutes.
+Access: Online."
+ ::= {acPMSS7Configuration 1}
+
+
+
+ acPMSS7ConfigurationResetTotalCounters OBJECT-TYPE
+ SYNTAX INTEGER {
+ resetCountersDone(1)
+,
+ resetTotalCounters(2)
+
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Total-Counters Reset. To reset the total counters, set the
+value of this object to resetTotalCounters(2).
+Access: Online."
+ ::= {acPMSS7Configuration 2}
+
+
+
+ acPMSS7Data OBJECT IDENTIFIER ::= {acPMSS7 2}
+
+
+ acPMSS7DataTimeFromStartOfInterval OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The time in seconds since the start of the current interval.
+MIB specific."
+ ::= {acPMSS7Data 1}
+
+
+
+ acPMSS7Links OBJECT IDENTIFIER ::= {acPMSS7Data 31}
+
+
+ -- ****************************************
+ -- acPMSS7TxMSU table declaration
+ -- ****************************************
+ acPMSS7TxMSUTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AcPMSS7TxMSUEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Number of transmitted MSU's per SS7 link."
+ ::= {acPMSS7Links 1}
+
+
+
+ -- ****************************************
+ -- acPMSS7TxMSU table entry
+ -- ****************************************
+ acPMSS7TxMSUEntry OBJECT-TYPE
+ SYNTAX AcPMSS7TxMSUEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX {acPMSS7TxMSULink,acPMSS7TxMSUInterval}
+ ::= {acPMSS7TxMSUTable 1}
+
+
+
+ -- ****************************************
+ -- acPMSS7TxMSU TABLE
+ -- ****************************************
+ AcPMSS7TxMSUEntry ::= SEQUENCE {
+ acPMSS7TxMSULink Unsigned32,
+ acPMSS7TxMSUInterval Unsigned32,
+ acPMSS7TxMSUVal Counter32,
+ acPMSS7TxMSUTotal Integer32
+ }
+
+
+
+ acPMSS7TxMSULink OBJECT-TYPE
+ SYNTAX Unsigned32 (0..63)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Link number.
+0 is the first link."
+ ::= {acPMSS7TxMSUEntry 1}
+
+
+
+ acPMSS7TxMSUInterval OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Interval index.
+0 - current period (incomplete monitoring - mid period).
+1 - Last full period.
+2 - One before last."
+ ::= {acPMSS7TxMSUEntry 2}
+
+
+
+ acPMSS7TxMSUVal OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Value of gauge or counter."
+ ::= {acPMSS7TxMSUEntry 3}
+
+
+
+ acPMSS7TxMSUTotal OBJECT-TYPE
+ SYNTAX Integer32 (-1..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total since last reset."
+ ::= {acPMSS7TxMSUEntry 4}
+
+
+
+ -- ****************************************
+ -- acPMSS7RxMSU table declaration
+ -- ****************************************
+ acPMSS7RxMSUTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AcPMSS7RxMSUEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Number of received MSU's per SS7 link."
+ ::= {acPMSS7Links 2}
+
+
+
+ -- ****************************************
+ -- acPMSS7RxMSU table entry
+ -- ****************************************
+ acPMSS7RxMSUEntry OBJECT-TYPE
+ SYNTAX AcPMSS7RxMSUEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX {acPMSS7RxMSULink,acPMSS7RxMSUInterval}
+ ::= {acPMSS7RxMSUTable 1}
+
+
+
+ -- ****************************************
+ -- acPMSS7RxMSU TABLE
+ -- ****************************************
+ AcPMSS7RxMSUEntry ::= SEQUENCE {
+ acPMSS7RxMSULink Unsigned32,
+ acPMSS7RxMSUInterval Unsigned32,
+ acPMSS7RxMSUVal Counter32,
+ acPMSS7RxMSUTotal Integer32
+ }
+
+
+
+ acPMSS7RxMSULink OBJECT-TYPE
+ SYNTAX Unsigned32 (0..63)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Link number.
+0 is the first link."
+ ::= {acPMSS7RxMSUEntry 1}
+
+
+
+ acPMSS7RxMSUInterval OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Interval index.
+0 - current period (incomplete monitoring - mid period).
+1 - Last full period.
+2 - One before last."
+ ::= {acPMSS7RxMSUEntry 2}
+
+
+
+ acPMSS7RxMSUVal OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Value of gauge or counter."
+ ::= {acPMSS7RxMSUEntry 3}
+
+
+
+ acPMSS7RxMSUTotal OBJECT-TYPE
+ SYNTAX Integer32 (-1..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total since last reset."
+ ::= {acPMSS7RxMSUEntry 4}
+
+
+
+ -- ****************************************
+ -- acPMSS7TxLSSU table declaration
+ -- ****************************************
+ acPMSS7TxLSSUTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AcPMSS7TxLSSUEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Number of transmitted LSSU's per SS7 link."
+ ::= {acPMSS7Links 3}
+
+
+
+ -- ****************************************
+ -- acPMSS7TxLSSU table entry
+ -- ****************************************
+ acPMSS7TxLSSUEntry OBJECT-TYPE
+ SYNTAX AcPMSS7TxLSSUEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX {acPMSS7TxLSSULink,acPMSS7TxLSSUInterval}
+ ::= {acPMSS7TxLSSUTable 1}
+
+
+
+ -- ****************************************
+ -- acPMSS7TxLSSU TABLE
+ -- ****************************************
+ AcPMSS7TxLSSUEntry ::= SEQUENCE {
+ acPMSS7TxLSSULink Unsigned32,
+ acPMSS7TxLSSUInterval Unsigned32,
+ acPMSS7TxLSSUVal Counter32,
+ acPMSS7TxLSSUTotal Integer32
+ }
+
+
+
+ acPMSS7TxLSSULink OBJECT-TYPE
+ SYNTAX Unsigned32 (0..63)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Link number.
+0 is the first link."
+ ::= {acPMSS7TxLSSUEntry 1}
+
+
+
+ acPMSS7TxLSSUInterval OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Interval index.
+0 - current period (incomplete monitoring - mid period).
+1 - Last full period.
+2 - One before last."
+ ::= {acPMSS7TxLSSUEntry 2}
+
+
+
+ acPMSS7TxLSSUVal OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Value of gauge or counter."
+ ::= {acPMSS7TxLSSUEntry 3}
+
+
+
+ acPMSS7TxLSSUTotal OBJECT-TYPE
+ SYNTAX Integer32 (-1..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total since last reset."
+ ::= {acPMSS7TxLSSUEntry 4}
+
+
+
+ -- ****************************************
+ -- acPMSS7RxLSSU table declaration
+ -- ****************************************
+ acPMSS7RxLSSUTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AcPMSS7RxLSSUEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Number of received LSSU's per SS7 link."
+ ::= {acPMSS7Links 4}
+
+
+
+ -- ****************************************
+ -- acPMSS7RxLSSU table entry
+ -- ****************************************
+ acPMSS7RxLSSUEntry OBJECT-TYPE
+ SYNTAX AcPMSS7RxLSSUEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX {acPMSS7RxLSSULink,acPMSS7RxLSSUInterval}
+ ::= {acPMSS7RxLSSUTable 1}
+
+
+
+ -- ****************************************
+ -- acPMSS7RxLSSU TABLE
+ -- ****************************************
+ AcPMSS7RxLSSUEntry ::= SEQUENCE {
+ acPMSS7RxLSSULink Unsigned32,
+ acPMSS7RxLSSUInterval Unsigned32,
+ acPMSS7RxLSSUVal Counter32,
+ acPMSS7RxLSSUTotal Integer32
+ }
+
+
+
+ acPMSS7RxLSSULink OBJECT-TYPE
+ SYNTAX Unsigned32 (0..63)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Link number.
+0 is the first link."
+ ::= {acPMSS7RxLSSUEntry 1}
+
+
+
+ acPMSS7RxLSSUInterval OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Interval index.
+0 - current period (incomplete monitoring - mid period).
+1 - Last full period.
+2 - One before last."
+ ::= {acPMSS7RxLSSUEntry 2}
+
+
+
+ acPMSS7RxLSSUVal OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Value of gauge or counter."
+ ::= {acPMSS7RxLSSUEntry 3}
+
+
+
+ acPMSS7RxLSSUTotal OBJECT-TYPE
+ SYNTAX Integer32 (-1..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total since last reset."
+ ::= {acPMSS7RxLSSUEntry 4}
+
+
+
+ -- ****************************************
+ -- acPMSS7TxFISU table declaration
+ -- ****************************************
+ acPMSS7TxFISUTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AcPMSS7TxFISUEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Number of transmitted FISU's per SS7 link."
+ ::= {acPMSS7Links 5}
+
+
+
+ -- ****************************************
+ -- acPMSS7TxFISU table entry
+ -- ****************************************
+ acPMSS7TxFISUEntry OBJECT-TYPE
+ SYNTAX AcPMSS7TxFISUEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX {acPMSS7TxFISULink,acPMSS7TxFISUInterval}
+ ::= {acPMSS7TxFISUTable 1}
+
+
+
+ -- ****************************************
+ -- acPMSS7TxFISU TABLE
+ -- ****************************************
+ AcPMSS7TxFISUEntry ::= SEQUENCE {
+ acPMSS7TxFISULink Unsigned32,
+ acPMSS7TxFISUInterval Unsigned32,
+ acPMSS7TxFISUVal Counter32,
+ acPMSS7TxFISUTotal Integer32
+ }
+
+
+
+ acPMSS7TxFISULink OBJECT-TYPE
+ SYNTAX Unsigned32 (0..63)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Link number.
+0 is the first link."
+ ::= {acPMSS7TxFISUEntry 1}
+
+
+
+ acPMSS7TxFISUInterval OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Interval index.
+0 - current period (incomplete monitoring - mid period).
+1 - Last full period.
+2 - One before last."
+ ::= {acPMSS7TxFISUEntry 2}
+
+
+
+ acPMSS7TxFISUVal OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Value of gauge or counter."
+ ::= {acPMSS7TxFISUEntry 3}
+
+
+
+ acPMSS7TxFISUTotal OBJECT-TYPE
+ SYNTAX Integer32 (-1..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total since last reset."
+ ::= {acPMSS7TxFISUEntry 4}
+
+
+
+ -- ****************************************
+ -- acPMSS7RxFISU table declaration
+ -- ****************************************
+ acPMSS7RxFISUTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AcPMSS7RxFISUEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Number of received FISU's per SS7 link."
+ ::= {acPMSS7Links 6}
+
+
+
+ -- ****************************************
+ -- acPMSS7RxFISU table entry
+ -- ****************************************
+ acPMSS7RxFISUEntry OBJECT-TYPE
+ SYNTAX AcPMSS7RxFISUEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX {acPMSS7RxFISULink,acPMSS7RxFISUInterval}
+ ::= {acPMSS7RxFISUTable 1}
+
+
+
+ -- ****************************************
+ -- acPMSS7RxFISU TABLE
+ -- ****************************************
+ AcPMSS7RxFISUEntry ::= SEQUENCE {
+ acPMSS7RxFISULink Unsigned32,
+ acPMSS7RxFISUInterval Unsigned32,
+ acPMSS7RxFISUVal Counter32,
+ acPMSS7RxFISUTotal Integer32
+ }
+
+
+
+ acPMSS7RxFISULink OBJECT-TYPE
+ SYNTAX Unsigned32 (0..63)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Link number.
+0 is the first link."
+ ::= {acPMSS7RxFISUEntry 1}
+
+
+
+ acPMSS7RxFISUInterval OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Interval index.
+0 - current period (incomplete monitoring - mid period).
+1 - Last full period.
+2 - One before last."
+ ::= {acPMSS7RxFISUEntry 2}
+
+
+
+ acPMSS7RxFISUVal OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Value of gauge or counter."
+ ::= {acPMSS7RxFISUEntry 3}
+
+
+
+ acPMSS7RxFISUTotal OBJECT-TYPE
+ SYNTAX Integer32 (-1..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total since last reset."
+ ::= {acPMSS7RxFISUEntry 4}
+
+
+
+ -- ****************************************
+ -- acPMSS7TxSignalUnits table declaration
+ -- ****************************************
+ acPMSS7TxSignalUnitsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AcPMSS7TxSignalUnitsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Number of transmitted Signaling units per SS7 link"
+ ::= {acPMSS7Links 7}
+
+
+
+ -- ****************************************
+ -- acPMSS7TxSignalUnits table entry
+ -- ****************************************
+ acPMSS7TxSignalUnitsEntry OBJECT-TYPE
+ SYNTAX AcPMSS7TxSignalUnitsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX {acPMSS7TxSignalUnitsLink,acPMSS7TxSignalUnitsInterval}
+ ::= {acPMSS7TxSignalUnitsTable 1}
+
+
+
+ -- ****************************************
+ -- acPMSS7TxSignalUnits TABLE
+ -- ****************************************
+ AcPMSS7TxSignalUnitsEntry ::= SEQUENCE {
+ acPMSS7TxSignalUnitsLink Unsigned32,
+ acPMSS7TxSignalUnitsInterval Unsigned32,
+ acPMSS7TxSignalUnitsVal Counter32,
+ acPMSS7TxSignalUnitsTotal Integer32
+ }
+
+
+
+ acPMSS7TxSignalUnitsLink OBJECT-TYPE
+ SYNTAX Unsigned32 (0..63)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Link number.
+0 is the first link."
+ ::= {acPMSS7TxSignalUnitsEntry 1}
+
+
+
+ acPMSS7TxSignalUnitsInterval OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Interval index.
+0 - current period (incomplete monitoring - mid period).
+1 - Last full period.
+2 - One before last."
+ ::= {acPMSS7TxSignalUnitsEntry 2}
+
+
+
+ acPMSS7TxSignalUnitsVal OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Value of gauge or counter."
+ ::= {acPMSS7TxSignalUnitsEntry 3}
+
+
+
+ acPMSS7TxSignalUnitsTotal OBJECT-TYPE
+ SYNTAX Integer32 (-1..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total since last reset."
+ ::= {acPMSS7TxSignalUnitsEntry 4}
+
+
+
+ -- ****************************************
+ -- acPMSS7RxSignalUnits table declaration
+ -- ****************************************
+ acPMSS7RxSignalUnitsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AcPMSS7RxSignalUnitsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Number of received Signaling units per SS7 link"
+ ::= {acPMSS7Links 8}
+
+
+
+ -- ****************************************
+ -- acPMSS7RxSignalUnits table entry
+ -- ****************************************
+ acPMSS7RxSignalUnitsEntry OBJECT-TYPE
+ SYNTAX AcPMSS7RxSignalUnitsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX {acPMSS7RxSignalUnitsLink,acPMSS7RxSignalUnitsInterval}
+ ::= {acPMSS7RxSignalUnitsTable 1}
+
+
+
+ -- ****************************************
+ -- acPMSS7RxSignalUnits TABLE
+ -- ****************************************
+ AcPMSS7RxSignalUnitsEntry ::= SEQUENCE {
+ acPMSS7RxSignalUnitsLink Unsigned32,
+ acPMSS7RxSignalUnitsInterval Unsigned32,
+ acPMSS7RxSignalUnitsVal Counter32,
+ acPMSS7RxSignalUnitsTotal Integer32
+ }
+
+
+
+ acPMSS7RxSignalUnitsLink OBJECT-TYPE
+ SYNTAX Unsigned32 (0..63)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Link number.
+0 is the first link."
+ ::= {acPMSS7RxSignalUnitsEntry 1}
+
+
+
+ acPMSS7RxSignalUnitsInterval OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Interval index.
+0 - current period (incomplete monitoring - mid period).
+1 - Last full period.
+2 - One before last."
+ ::= {acPMSS7RxSignalUnitsEntry 2}
+
+
+
+ acPMSS7RxSignalUnitsVal OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Value of gauge or counter."
+ ::= {acPMSS7RxSignalUnitsEntry 3}
+
+
+
+ acPMSS7RxSignalUnitsTotal OBJECT-TYPE
+ SYNTAX Integer32 (-1..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total since last reset."
+ ::= {acPMSS7RxSignalUnitsEntry 4}
+
+
+
+ -- ****************************************
+ -- acPMSS7TxOctets table declaration
+ -- ****************************************
+ acPMSS7TxOctetsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AcPMSS7TxOctetsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Number of transmitted Octets per SS7 link - Q.752 3.1"
+ ::= {acPMSS7Links 9}
+
+
+
+ -- ****************************************
+ -- acPMSS7TxOctets table entry
+ -- ****************************************
+ acPMSS7TxOctetsEntry OBJECT-TYPE
+ SYNTAX AcPMSS7TxOctetsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX {acPMSS7TxOctetsLink,acPMSS7TxOctetsInterval}
+ ::= {acPMSS7TxOctetsTable 1}
+
+
+
+ -- ****************************************
+ -- acPMSS7TxOctets TABLE
+ -- ****************************************
+ AcPMSS7TxOctetsEntry ::= SEQUENCE {
+ acPMSS7TxOctetsLink Unsigned32,
+ acPMSS7TxOctetsInterval Unsigned32,
+ acPMSS7TxOctetsVal Counter32,
+ acPMSS7TxOctetsTotal Integer32
+ }
+
+
+
+ acPMSS7TxOctetsLink OBJECT-TYPE
+ SYNTAX Unsigned32 (0..63)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Link number.
+0 is the first link."
+ ::= {acPMSS7TxOctetsEntry 1}
+
+
+
+ acPMSS7TxOctetsInterval OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Interval index.
+0 - current period (incomplete monitoring - mid period).
+1 - Last full period.
+2 - One before last."
+ ::= {acPMSS7TxOctetsEntry 2}
+
+
+
+ acPMSS7TxOctetsVal OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Value of gauge or counter."
+ ::= {acPMSS7TxOctetsEntry 3}
+
+
+
+ acPMSS7TxOctetsTotal OBJECT-TYPE
+ SYNTAX Integer32 (-1..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total since last reset."
+ ::= {acPMSS7TxOctetsEntry 4}
+
+
+
+ -- ****************************************
+ -- acPMSS7RxOctets table declaration
+ -- ****************************************
+ acPMSS7RxOctetsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AcPMSS7RxOctetsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Number of received Octets per SS7 link - Q.752 3.4"
+ ::= {acPMSS7Links 10}
+
+
+
+ -- ****************************************
+ -- acPMSS7RxOctets table entry
+ -- ****************************************
+ acPMSS7RxOctetsEntry OBJECT-TYPE
+ SYNTAX AcPMSS7RxOctetsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX {acPMSS7RxOctetsLink,acPMSS7RxOctetsInterval}
+ ::= {acPMSS7RxOctetsTable 1}
+
+
+
+ -- ****************************************
+ -- acPMSS7RxOctets TABLE
+ -- ****************************************
+ AcPMSS7RxOctetsEntry ::= SEQUENCE {
+ acPMSS7RxOctetsLink Unsigned32,
+ acPMSS7RxOctetsInterval Unsigned32,
+ acPMSS7RxOctetsVal Counter32,
+ acPMSS7RxOctetsTotal Integer32
+ }
+
+
+
+ acPMSS7RxOctetsLink OBJECT-TYPE
+ SYNTAX Unsigned32 (0..63)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Link number.
+0 is the first link."
+ ::= {acPMSS7RxOctetsEntry 1}
+
+
+
+ acPMSS7RxOctetsInterval OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Interval index.
+0 - current period (incomplete monitoring - mid period).
+1 - Last full period.
+2 - One before last."
+ ::= {acPMSS7RxOctetsEntry 2}
+
+
+
+ acPMSS7RxOctetsVal OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Value of gauge or counter."
+ ::= {acPMSS7RxOctetsEntry 3}
+
+
+
+ acPMSS7RxOctetsTotal OBJECT-TYPE
+ SYNTAX Integer32 (-1..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total since last reset."
+ ::= {acPMSS7RxOctetsEntry 4}
+
+
+
+ -- ****************************************
+ -- acPMSS7MTP2NoAckRx table declaration
+ -- ****************************************
+ acPMSS7MTP2NoAckRxTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AcPMSS7MTP2NoAckRxEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Number of MTP2 Not Ack received (from far end) per SS7 link - Q.752 1.9"
+ ::= {acPMSS7Links 11}
+
+
+
+ -- ****************************************
+ -- acPMSS7MTP2NoAckRx table entry
+ -- ****************************************
+ acPMSS7MTP2NoAckRxEntry OBJECT-TYPE
+ SYNTAX AcPMSS7MTP2NoAckRxEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX {acPMSS7MTP2NoAckRxLink,acPMSS7MTP2NoAckRxInterval}
+ ::= {acPMSS7MTP2NoAckRxTable 1}
+
+
+
+ -- ****************************************
+ -- acPMSS7MTP2NoAckRx TABLE
+ -- ****************************************
+ AcPMSS7MTP2NoAckRxEntry ::= SEQUENCE {
+ acPMSS7MTP2NoAckRxLink Unsigned32,
+ acPMSS7MTP2NoAckRxInterval Unsigned32,
+ acPMSS7MTP2NoAckRxVal Counter32,
+ acPMSS7MTP2NoAckRxTotal Integer32
+ }
+
+
+
+ acPMSS7MTP2NoAckRxLink OBJECT-TYPE
+ SYNTAX Unsigned32 (0..63)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Link number.
+0 is the first link."
+ ::= {acPMSS7MTP2NoAckRxEntry 1}
+
+
+
+ acPMSS7MTP2NoAckRxInterval OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Interval index.
+0 - current period (incomplete monitoring - mid period).
+1 - Last full period.
+2 - One before last."
+ ::= {acPMSS7MTP2NoAckRxEntry 2}
+
+
+
+ acPMSS7MTP2NoAckRxVal OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Value of gauge or counter."
+ ::= {acPMSS7MTP2NoAckRxEntry 3}
+
+
+
+ acPMSS7MTP2NoAckRxTotal OBJECT-TYPE
+ SYNTAX Integer32 (-1..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total since last reset."
+ ::= {acPMSS7MTP2NoAckRxEntry 4}
+
+
+
+ -- ****************************************
+ -- acPMSS7DiscMSU table declaration
+ -- ****************************************
+ acPMSS7DiscMSUTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AcPMSS7DiscMSUEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "MSUs discarded due to SL congestion - transmit and receive - Q.752 3.10"
+ ::= {acPMSS7Links 12}
+
+
+
+ -- ****************************************
+ -- acPMSS7DiscMSU table entry
+ -- ****************************************
+ acPMSS7DiscMSUEntry OBJECT-TYPE
+ SYNTAX AcPMSS7DiscMSUEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX {acPMSS7DiscMSULink,acPMSS7DiscMSUInterval}
+ ::= {acPMSS7DiscMSUTable 1}
+
+
+
+ -- ****************************************
+ -- acPMSS7DiscMSU TABLE
+ -- ****************************************
+ AcPMSS7DiscMSUEntry ::= SEQUENCE {
+ acPMSS7DiscMSULink Unsigned32,
+ acPMSS7DiscMSUInterval Unsigned32,
+ acPMSS7DiscMSUVal Counter32,
+ acPMSS7DiscMSUTotal Integer32
+ }
+
+
+
+ acPMSS7DiscMSULink OBJECT-TYPE
+ SYNTAX Unsigned32 (0..63)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Link number.
+0 is the first link."
+ ::= {acPMSS7DiscMSUEntry 1}
+
+
+
+ acPMSS7DiscMSUInterval OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Interval index.
+0 - current period (incomplete monitoring - mid period).
+1 - Last full period.
+2 - One before last."
+ ::= {acPMSS7DiscMSUEntry 2}
+
+
+
+ acPMSS7DiscMSUVal OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Value of gauge or counter."
+ ::= {acPMSS7DiscMSUEntry 3}
+
+
+
+ acPMSS7DiscMSUTotal OBJECT-TYPE
+ SYNTAX Integer32 (-1..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total since last reset."
+ ::= {acPMSS7DiscMSUEntry 4}
+
+
+
+ -- ****************************************
+ -- acPMSS7InService table declaration
+ -- ****************************************
+ acPMSS7InServiceTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AcPMSS7InServiceEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Duration of SS7 link at in-service state in percentage (in last 30 minutes) - Q.752 1.1"
+ ::= {acPMSS7Links 13}
+
+
+
+ -- ****************************************
+ -- acPMSS7InService table entry
+ -- ****************************************
+ acPMSS7InServiceEntry OBJECT-TYPE
+ SYNTAX AcPMSS7InServiceEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX {acPMSS7InServiceLink,acPMSS7InServiceInterval}
+ ::= {acPMSS7InServiceTable 1}
+
+
+
+ -- ****************************************
+ -- acPMSS7InService TABLE
+ -- ****************************************
+ AcPMSS7InServiceEntry ::= SEQUENCE {
+ acPMSS7InServiceLink Unsigned32,
+ acPMSS7InServiceInterval Unsigned32,
+ acPMSS7InServiceVal Gauge32,
+ acPMSS7InServiceTimeAboveHighThreshold Integer32,
+ acPMSS7InServiceTimeBetweenThresholds Integer32
+ }
+
+
+
+ acPMSS7InServiceLink OBJECT-TYPE
+ SYNTAX Unsigned32 (0..63)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Link number.
+0 is the first link."
+ ::= {acPMSS7InServiceEntry 1}
+
+
+
+ acPMSS7InServiceInterval OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Interval index.
+0 - current period (incomplete monitoring - mid period).
+1 - Last full period.
+2 - One before last."
+ ::= {acPMSS7InServiceEntry 2}
+
+
+
+ acPMSS7InServiceVal OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Value of gauge or counter."
+ ::= {acPMSS7InServiceEntry 3}
+
+
+
+ acPMSS7InServiceTimeAboveHighThreshold OBJECT-TYPE
+ SYNTAX Integer32 (-1..100)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Percent of interval time for which gauge is above what was determined
+as the high threshold. In this case - 'In Service'."
+ ::= {acPMSS7InServiceEntry 4}
+
+
+
+ acPMSS7InServiceTimeBetweenThresholds OBJECT-TYPE
+ SYNTAX Integer32 (-1..100)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Percent of interval time for which gauge is between what were
+determined as the low and high thresholds. In this case -
+not 'In Service'."
+ ::= {acPMSS7InServiceEntry 5}
+
+
+
+ -- ****************************************
+ -- acPMSS7OutOfService table declaration
+ -- ****************************************
+ acPMSS7OutOfServiceTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AcPMSS7OutOfServiceEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Duration of SS7 link at out-of-service state in percentage (in last 30 minutes) - Q.752 2.1"
+ ::= {acPMSS7Links 14}
+
+
+
+ -- ****************************************
+ -- acPMSS7OutOfService table entry
+ -- ****************************************
+ acPMSS7OutOfServiceEntry OBJECT-TYPE
+ SYNTAX AcPMSS7OutOfServiceEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX {acPMSS7OutOfServiceLink,acPMSS7OutOfServiceInterval}
+ ::= {acPMSS7OutOfServiceTable 1}
+
+
+
+ -- ****************************************
+ -- acPMSS7OutOfService TABLE
+ -- ****************************************
+ AcPMSS7OutOfServiceEntry ::= SEQUENCE {
+ acPMSS7OutOfServiceLink Unsigned32,
+ acPMSS7OutOfServiceInterval Unsigned32,
+ acPMSS7OutOfServiceVal Gauge32,
+ acPMSS7OutOfServiceTimeAboveHighThreshold Integer32,
+ acPMSS7OutOfServiceTimeBetweenThresholds Integer32
+ }
+
+
+
+ acPMSS7OutOfServiceLink OBJECT-TYPE
+ SYNTAX Unsigned32 (0..63)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Link number.
+0 is the first link."
+ ::= {acPMSS7OutOfServiceEntry 1}
+
+
+
+ acPMSS7OutOfServiceInterval OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Interval index.
+0 - current period (incomplete monitoring - mid period).
+1 - Last full period.
+2 - One before last."
+ ::= {acPMSS7OutOfServiceEntry 2}
+
+
+
+ acPMSS7OutOfServiceVal OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Value of gauge or counter."
+ ::= {acPMSS7OutOfServiceEntry 3}
+
+
+
+ acPMSS7OutOfServiceTimeAboveHighThreshold OBJECT-TYPE
+ SYNTAX Integer32 (-1..100)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Percent of interval time for which gauge is above what was determined
+as the high threshold. In this case - 'Out Of Service'."
+ ::= {acPMSS7OutOfServiceEntry 4}
+
+
+
+ acPMSS7OutOfServiceTimeBetweenThresholds OBJECT-TYPE
+ SYNTAX Integer32 (-1..100)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Percent of interval time for which gauge is between what were
+determined as the low and high thresholds. In this case -
+not 'Out of Service'."
+ ::= {acPMSS7OutOfServiceEntry 5}
+
+
+
+ acPMSS7LinkSets OBJECT IDENTIFIER ::= {acPMSS7Data 41}
+
+
+ -- ****************************************
+ -- acPMSS7SN0LSOutOfService table declaration
+ -- ****************************************
+ acPMSS7SN0LSOutOfServiceTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AcPMSS7SN0LSOutOfServiceEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Duration of SS7 linkSet within Signaling node 0 at Out-of-service state in percentage (in last 30 minutes) -Q.752 5.2"
+ ::= {acPMSS7LinkSets 1}
+
+
+
+ -- ****************************************
+ -- acPMSS7SN0LSOutOfService table entry
+ -- ****************************************
+ acPMSS7SN0LSOutOfServiceEntry OBJECT-TYPE
+ SYNTAX AcPMSS7SN0LSOutOfServiceEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX {acPMSS7SN0LSOutOfServiceLinkSet,acPMSS7SN0LSOutOfServiceInterval}
+ ::= {acPMSS7SN0LSOutOfServiceTable 1}
+
+
+
+ -- ****************************************
+ -- acPMSS7SN0LSOutOfService TABLE
+ -- ****************************************
+ AcPMSS7SN0LSOutOfServiceEntry ::= SEQUENCE {
+ acPMSS7SN0LSOutOfServiceLinkSet Unsigned32,
+ acPMSS7SN0LSOutOfServiceInterval Unsigned32,
+ acPMSS7SN0LSOutOfServiceVal Gauge32,
+ acPMSS7SN0LSOutOfServiceTimeAboveHighThreshold Integer32,
+ acPMSS7SN0LSOutOfServiceTimeBetweenThresholds Integer32
+ }
+
+
+
+ acPMSS7SN0LSOutOfServiceLinkSet OBJECT-TYPE
+ SYNTAX Unsigned32 (0..31)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Link Set number.
+0 is the first link."
+ ::= {acPMSS7SN0LSOutOfServiceEntry 1}
+
+
+
+ acPMSS7SN0LSOutOfServiceInterval OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Interval index.
+0 - current period (incomplete monitoring - mid period).
+1 - Last full period.
+2 - One before last."
+ ::= {acPMSS7SN0LSOutOfServiceEntry 2}
+
+
+
+ acPMSS7SN0LSOutOfServiceVal OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Value of gauge or counter."
+ ::= {acPMSS7SN0LSOutOfServiceEntry 3}
+
+
+
+ acPMSS7SN0LSOutOfServiceTimeAboveHighThreshold OBJECT-TYPE
+ SYNTAX Integer32 (-1..100)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Percent of interval time for which gauge is above what was determined
+as the high threshold. In this case - 'Out Of Service'."
+ ::= {acPMSS7SN0LSOutOfServiceEntry 4}
+
+
+
+ acPMSS7SN0LSOutOfServiceTimeBetweenThresholds OBJECT-TYPE
+ SYNTAX Integer32 (-1..100)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Percent of interval time for which gauge is between what were
+determined as the low and high thresholds. In this case -
+not 'Out of Service'."
+ ::= {acPMSS7SN0LSOutOfServiceEntry 5}
+
+
+
+ -- ****************************************
+ -- acPMSS7SN1LSOutOfService table declaration
+ -- ****************************************
+ acPMSS7SN1LSOutOfServiceTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AcPMSS7SN1LSOutOfServiceEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Duration of SS7 linkSet within Signaling node 1 at Out-of-service state in percentage (in last 30 minutes) -Q.752 5.2"
+ ::= {acPMSS7LinkSets 2}
+
+
+
+ -- ****************************************
+ -- acPMSS7SN1LSOutOfService table entry
+ -- ****************************************
+ acPMSS7SN1LSOutOfServiceEntry OBJECT-TYPE
+ SYNTAX AcPMSS7SN1LSOutOfServiceEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX {acPMSS7SN1LSOutOfServiceLinkSet,acPMSS7SN1LSOutOfServiceInterval}
+ ::= {acPMSS7SN1LSOutOfServiceTable 1}
+
+
+
+ -- ****************************************
+ -- acPMSS7SN1LSOutOfService TABLE
+ -- ****************************************
+ AcPMSS7SN1LSOutOfServiceEntry ::= SEQUENCE {
+ acPMSS7SN1LSOutOfServiceLinkSet Unsigned32,
+ acPMSS7SN1LSOutOfServiceInterval Unsigned32,
+ acPMSS7SN1LSOutOfServiceVal Gauge32,
+ acPMSS7SN1LSOutOfServiceTimeAboveHighThreshold Integer32,
+ acPMSS7SN1LSOutOfServiceTimeBetweenThresholds Integer32
+ }
+
+
+
+ acPMSS7SN1LSOutOfServiceLinkSet OBJECT-TYPE
+ SYNTAX Unsigned32 (0..31)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Link Set number.
+0 is the first link."
+ ::= {acPMSS7SN1LSOutOfServiceEntry 1}
+
+
+
+ acPMSS7SN1LSOutOfServiceInterval OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Interval index.
+0 - current period (incomplete monitoring - mid period).
+1 - Last full period.
+2 - One before last."
+ ::= {acPMSS7SN1LSOutOfServiceEntry 2}
+
+
+
+ acPMSS7SN1LSOutOfServiceVal OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Value of gauge or counter."
+ ::= {acPMSS7SN1LSOutOfServiceEntry 3}
+
+
+
+ acPMSS7SN1LSOutOfServiceTimeAboveHighThreshold OBJECT-TYPE
+ SYNTAX Integer32 (-1..100)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Percent of interval time for which gauge is above what was determined
+as the high threshold. In this case - 'Out Of Service'."
+ ::= {acPMSS7SN1LSOutOfServiceEntry 4}
+
+
+
+ acPMSS7SN1LSOutOfServiceTimeBetweenThresholds OBJECT-TYPE
+ SYNTAX Integer32 (-1..100)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Percent of interval time for which gauge is between what were
+determined as the low and high thresholds. In this case -
+not 'Out of Service'."
+ ::= {acPMSS7SN1LSOutOfServiceEntry 5}
+
+
+
+ acPMSS7SignalingNodes OBJECT IDENTIFIER ::= {acPMSS7Data 51}
+
+
+ -- ****************************************
+ -- acPMSS7TxMTP3Octets table declaration
+ -- ****************************************
+ acPMSS7TxMTP3OctetsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AcPMSS7TxMTP3OctetsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Number of transmitted MTP3 octets per SS7 MTP3 node"
+ ::= {acPMSS7SignalingNodes 1}
+
+
+
+ -- ****************************************
+ -- acPMSS7TxMTP3Octets table entry
+ -- ****************************************
+ acPMSS7TxMTP3OctetsEntry OBJECT-TYPE
+ SYNTAX AcPMSS7TxMTP3OctetsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX {acPMSS7TxMTP3OctetsSN,acPMSS7TxMTP3OctetsInterval}
+ ::= {acPMSS7TxMTP3OctetsTable 1}
+
+
+
+ -- ****************************************
+ -- acPMSS7TxMTP3Octets TABLE
+ -- ****************************************
+ AcPMSS7TxMTP3OctetsEntry ::= SEQUENCE {
+ acPMSS7TxMTP3OctetsSN Unsigned32,
+ acPMSS7TxMTP3OctetsInterval Unsigned32,
+ acPMSS7TxMTP3OctetsVal Counter32,
+ acPMSS7TxMTP3OctetsTotal Integer32
+ }
+
+
+
+ acPMSS7TxMTP3OctetsSN OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "SN number.
+0 is the first SN."
+ ::= {acPMSS7TxMTP3OctetsEntry 1}
+
+
+
+ acPMSS7TxMTP3OctetsInterval OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Interval index.
+0 - current period (incomplete monitoring - mid period).
+1 - Last full period.
+2 - One before last."
+ ::= {acPMSS7TxMTP3OctetsEntry 2}
+
+
+
+ acPMSS7TxMTP3OctetsVal OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Value of gauge or counter."
+ ::= {acPMSS7TxMTP3OctetsEntry 3}
+
+
+
+ acPMSS7TxMTP3OctetsTotal OBJECT-TYPE
+ SYNTAX Integer32 (-1..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total since last reset."
+ ::= {acPMSS7TxMTP3OctetsEntry 4}
+
+
+
+ -- ****************************************
+ -- acPMSS7RxMTP3Octets table declaration
+ -- ****************************************
+ acPMSS7RxMTP3OctetsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AcPMSS7RxMTP3OctetsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Number of received MTP3 octets per SS7 MTP3 node"
+ ::= {acPMSS7SignalingNodes 2}
+
+
+
+ -- ****************************************
+ -- acPMSS7RxMTP3Octets table entry
+ -- ****************************************
+ acPMSS7RxMTP3OctetsEntry OBJECT-TYPE
+ SYNTAX AcPMSS7RxMTP3OctetsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX {acPMSS7RxMTP3OctetsSN,acPMSS7RxMTP3OctetsInterval}
+ ::= {acPMSS7RxMTP3OctetsTable 1}
+
+
+
+ -- ****************************************
+ -- acPMSS7RxMTP3Octets TABLE
+ -- ****************************************
+ AcPMSS7RxMTP3OctetsEntry ::= SEQUENCE {
+ acPMSS7RxMTP3OctetsSN Unsigned32,
+ acPMSS7RxMTP3OctetsInterval Unsigned32,
+ acPMSS7RxMTP3OctetsVal Counter32,
+ acPMSS7RxMTP3OctetsTotal Integer32
+ }
+
+
+
+ acPMSS7RxMTP3OctetsSN OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "SN number.
+0 is the first SN."
+ ::= {acPMSS7RxMTP3OctetsEntry 1}
+
+
+
+ acPMSS7RxMTP3OctetsInterval OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Interval index.
+0 - current period (incomplete monitoring - mid period).
+1 - Last full period.
+2 - One before last."
+ ::= {acPMSS7RxMTP3OctetsEntry 2}
+
+
+
+ acPMSS7RxMTP3OctetsVal OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Value of gauge or counter."
+ ::= {acPMSS7RxMTP3OctetsEntry 3}
+
+
+
+ acPMSS7RxMTP3OctetsTotal OBJECT-TYPE
+ SYNTAX Integer32 (-1..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total since last reset."
+ ::= {acPMSS7RxMTP3OctetsEntry 4}
+
+
+
+ -- ****************************************
+ -- acPMSS7TxMTP3MSU table declaration
+ -- ****************************************
+ acPMSS7TxMTP3MSUTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AcPMSS7TxMTP3MSUEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Number of transmitted MTP3 MSU's per SS7 MTP3 node"
+ ::= {acPMSS7SignalingNodes 3}
+
+
+
+ -- ****************************************
+ -- acPMSS7TxMTP3MSU table entry
+ -- ****************************************
+ acPMSS7TxMTP3MSUEntry OBJECT-TYPE
+ SYNTAX AcPMSS7TxMTP3MSUEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX {acPMSS7TxMTP3MSUSN,acPMSS7TxMTP3MSUInterval}
+ ::= {acPMSS7TxMTP3MSUTable 1}
+
+
+
+ -- ****************************************
+ -- acPMSS7TxMTP3MSU TABLE
+ -- ****************************************
+ AcPMSS7TxMTP3MSUEntry ::= SEQUENCE {
+ acPMSS7TxMTP3MSUSN Unsigned32,
+ acPMSS7TxMTP3MSUInterval Unsigned32,
+ acPMSS7TxMTP3MSUVal Counter32,
+ acPMSS7TxMTP3MSUTotal Integer32
+ }
+
+
+
+ acPMSS7TxMTP3MSUSN OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "SN number.
+0 is the first SN."
+ ::= {acPMSS7TxMTP3MSUEntry 1}
+
+
+
+ acPMSS7TxMTP3MSUInterval OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Interval index.
+0 - current period (incomplete monitoring - mid period).
+1 - Last full period.
+2 - One before last."
+ ::= {acPMSS7TxMTP3MSUEntry 2}
+
+
+
+ acPMSS7TxMTP3MSUVal OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Value of gauge or counter."
+ ::= {acPMSS7TxMTP3MSUEntry 3}
+
+
+
+ acPMSS7TxMTP3MSUTotal OBJECT-TYPE
+ SYNTAX Integer32 (-1..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total since last reset."
+ ::= {acPMSS7TxMTP3MSUEntry 4}
+
+
+
+ -- ****************************************
+ -- acPMSS7RxMTP3MSU table declaration
+ -- ****************************************
+ acPMSS7RxMTP3MSUTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AcPMSS7RxMTP3MSUEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Number of received MTP3 MSU's per SS7 MTP3 node"
+ ::= {acPMSS7SignalingNodes 4}
+
+
+
+ -- ****************************************
+ -- acPMSS7RxMTP3MSU table entry
+ -- ****************************************
+ acPMSS7RxMTP3MSUEntry OBJECT-TYPE
+ SYNTAX AcPMSS7RxMTP3MSUEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX {acPMSS7RxMTP3MSUSN,acPMSS7RxMTP3MSUInterval}
+ ::= {acPMSS7RxMTP3MSUTable 1}
+
+
+
+ -- ****************************************
+ -- acPMSS7RxMTP3MSU TABLE
+ -- ****************************************
+ AcPMSS7RxMTP3MSUEntry ::= SEQUENCE {
+ acPMSS7RxMTP3MSUSN Unsigned32,
+ acPMSS7RxMTP3MSUInterval Unsigned32,
+ acPMSS7RxMTP3MSUVal Counter32,
+ acPMSS7RxMTP3MSUTotal Integer32
+ }
+
+
+
+ acPMSS7RxMTP3MSUSN OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "SN number.
+0 is the first SN."
+ ::= {acPMSS7RxMTP3MSUEntry 1}
+
+
+
+ acPMSS7RxMTP3MSUInterval OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Interval index.
+0 - current period (incomplete monitoring - mid period).
+1 - Last full period.
+2 - One before last."
+ ::= {acPMSS7RxMTP3MSUEntry 2}
+
+
+
+ acPMSS7RxMTP3MSUVal OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Value of gauge or counter."
+ ::= {acPMSS7RxMTP3MSUEntry 3}
+
+
+
+ acPMSS7RxMTP3MSUTotal OBJECT-TYPE
+ SYNTAX Integer32 (-1..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total since last reset."
+ ::= {acPMSS7RxMTP3MSUEntry 4}
+
+
+
+ -- ****************************************
+ -- acPMSS7TxMTP3UPU table declaration
+ -- ****************************************
+ acPMSS7TxMTP3UPUTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AcPMSS7TxMTP3UPUEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Number of transmitted MTP3 User Part Unavailable messages per SS7 MTP3 node"
+ ::= {acPMSS7SignalingNodes 5}
+
+
+
+ -- ****************************************
+ -- acPMSS7TxMTP3UPU table entry
+ -- ****************************************
+ acPMSS7TxMTP3UPUEntry OBJECT-TYPE
+ SYNTAX AcPMSS7TxMTP3UPUEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX {acPMSS7TxMTP3UPUSN,acPMSS7TxMTP3UPUInterval}
+ ::= {acPMSS7TxMTP3UPUTable 1}
+
+
+
+ -- ****************************************
+ -- acPMSS7TxMTP3UPU TABLE
+ -- ****************************************
+ AcPMSS7TxMTP3UPUEntry ::= SEQUENCE {
+ acPMSS7TxMTP3UPUSN Unsigned32,
+ acPMSS7TxMTP3UPUInterval Unsigned32,
+ acPMSS7TxMTP3UPUVal Counter32,
+ acPMSS7TxMTP3UPUTotal Integer32
+ }
+
+
+
+ acPMSS7TxMTP3UPUSN OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "SN number.
+0 is the first SN."
+ ::= {acPMSS7TxMTP3UPUEntry 1}
+
+
+
+ acPMSS7TxMTP3UPUInterval OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Interval index.
+0 - current period (incomplete monitoring - mid period).
+1 - Last full period.
+2 - One before last."
+ ::= {acPMSS7TxMTP3UPUEntry 2}
+
+
+
+ acPMSS7TxMTP3UPUVal OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Value of gauge or counter."
+ ::= {acPMSS7TxMTP3UPUEntry 3}
+
+
+
+ acPMSS7TxMTP3UPUTotal OBJECT-TYPE
+ SYNTAX Integer32 (-1..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total since last reset."
+ ::= {acPMSS7TxMTP3UPUEntry 4}
+
+
+
+ -- ****************************************
+ -- acPMSS7RxMTP3UPU table declaration
+ -- ****************************************
+ acPMSS7RxMTP3UPUTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AcPMSS7RxMTP3UPUEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Number of received MTP3 User Part Unavailable messages per SS7 MTP3 node"
+ ::= {acPMSS7SignalingNodes 6}
+
+
+
+ -- ****************************************
+ -- acPMSS7RxMTP3UPU table entry
+ -- ****************************************
+ acPMSS7RxMTP3UPUEntry OBJECT-TYPE
+ SYNTAX AcPMSS7RxMTP3UPUEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX {acPMSS7RxMTP3UPUSN,acPMSS7RxMTP3UPUInterval}
+ ::= {acPMSS7RxMTP3UPUTable 1}
+
+
+
+ -- ****************************************
+ -- acPMSS7RxMTP3UPU TABLE
+ -- ****************************************
+ AcPMSS7RxMTP3UPUEntry ::= SEQUENCE {
+ acPMSS7RxMTP3UPUSN Unsigned32,
+ acPMSS7RxMTP3UPUInterval Unsigned32,
+ acPMSS7RxMTP3UPUVal Counter32,
+ acPMSS7RxMTP3UPUTotal Integer32
+ }
+
+
+
+ acPMSS7RxMTP3UPUSN OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "SN number.
+0 is the first SN."
+ ::= {acPMSS7RxMTP3UPUEntry 1}
+
+
+
+ acPMSS7RxMTP3UPUInterval OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Interval index.
+0 - current period (incomplete monitoring - mid period).
+1 - Last full period.
+2 - One before last."
+ ::= {acPMSS7RxMTP3UPUEntry 2}
+
+
+
+ acPMSS7RxMTP3UPUVal OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Value of gauge or counter."
+ ::= {acPMSS7RxMTP3UPUEntry 3}
+
+
+
+ acPMSS7RxMTP3UPUTotal OBJECT-TYPE
+ SYNTAX Integer32 (-1..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total since last reset."
+ ::= {acPMSS7RxMTP3UPUEntry 4}
+
+
+
+ -- ****************************************
+ -- acPMSS7MTP3MSUDiscarded table declaration
+ -- ****************************************
+ acPMSS7MTP3MSUDiscardedTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AcPMSS7MTP3MSUDiscardedEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Number of discarded MTP3 MSU's per SS7 MTP3 node"
+ ::= {acPMSS7SignalingNodes 7}
+
+
+
+ -- ****************************************
+ -- acPMSS7MTP3MSUDiscarded table entry
+ -- ****************************************
+ acPMSS7MTP3MSUDiscardedEntry OBJECT-TYPE
+ SYNTAX AcPMSS7MTP3MSUDiscardedEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX {acPMSS7MTP3MSUDiscardedSN,acPMSS7MTP3MSUDiscardedInterval}
+ ::= {acPMSS7MTP3MSUDiscardedTable 1}
+
+
+
+ -- ****************************************
+ -- acPMSS7MTP3MSUDiscarded TABLE
+ -- ****************************************
+ AcPMSS7MTP3MSUDiscardedEntry ::= SEQUENCE {
+ acPMSS7MTP3MSUDiscardedSN Unsigned32,
+ acPMSS7MTP3MSUDiscardedInterval Unsigned32,
+ acPMSS7MTP3MSUDiscardedVal Counter32,
+ acPMSS7MTP3MSUDiscardedTotal Integer32
+ }
+
+
+
+ acPMSS7MTP3MSUDiscardedSN OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "SN number.
+0 is the first SN."
+ ::= {acPMSS7MTP3MSUDiscardedEntry 1}
+
+
+
+ acPMSS7MTP3MSUDiscardedInterval OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Interval index.
+0 - current period (incomplete monitoring - mid period).
+1 - Last full period.
+2 - One before last."
+ ::= {acPMSS7MTP3MSUDiscardedEntry 2}
+
+
+
+ acPMSS7MTP3MSUDiscardedVal OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Value of gauge or counter."
+ ::= {acPMSS7MTP3MSUDiscardedEntry 3}
+
+
+
+ acPMSS7MTP3MSUDiscardedTotal OBJECT-TYPE
+ SYNTAX Integer32 (-1..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total since last reset."
+ ::= {acPMSS7MTP3MSUDiscardedEntry 4}
+
+
+
+ -- ****************************************
+ -- acPMSS7MTP3MSUDiscardedRtDataErr table declaration
+ -- ****************************************
+ acPMSS7MTP3MSUDiscardedRtDataErrTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AcPMSS7MTP3MSUDiscardedRtDataErrEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Number of MTP3 Msu's discarded Due to Routing Data error per SS7 MTP3 node - Q.752 5.5"
+ ::= {acPMSS7SignalingNodes 8}
+
+
+
+ -- ****************************************
+ -- acPMSS7MTP3MSUDiscardedRtDataErr table entry
+ -- ****************************************
+ acPMSS7MTP3MSUDiscardedRtDataErrEntry OBJECT-TYPE
+ SYNTAX AcPMSS7MTP3MSUDiscardedRtDataErrEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX {acPMSS7MTP3MSUDiscardedRtDataErrSN,acPMSS7MTP3MSUDiscardedRtDataErrInterval}
+ ::= {acPMSS7MTP3MSUDiscardedRtDataErrTable 1}
+
+
+
+ -- ****************************************
+ -- acPMSS7MTP3MSUDiscardedRtDataErr TABLE
+ -- ****************************************
+ AcPMSS7MTP3MSUDiscardedRtDataErrEntry ::= SEQUENCE {
+ acPMSS7MTP3MSUDiscardedRtDataErrSN Unsigned32,
+ acPMSS7MTP3MSUDiscardedRtDataErrInterval Unsigned32,
+ acPMSS7MTP3MSUDiscardedRtDataErrVal Counter32,
+ acPMSS7MTP3MSUDiscardedRtDataErrTotal Integer32
+ }
+
+
+
+ acPMSS7MTP3MSUDiscardedRtDataErrSN OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "SN number.
+0 is the first SN."
+ ::= {acPMSS7MTP3MSUDiscardedRtDataErrEntry 1}
+
+
+
+ acPMSS7MTP3MSUDiscardedRtDataErrInterval OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Interval index.
+0 - current period (incomplete monitoring - mid period).
+1 - Last full period.
+2 - One before last."
+ ::= {acPMSS7MTP3MSUDiscardedRtDataErrEntry 2}
+
+
+
+ acPMSS7MTP3MSUDiscardedRtDataErrVal OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Value of gauge or counter."
+ ::= {acPMSS7MTP3MSUDiscardedRtDataErrEntry 3}
+
+
+
+ acPMSS7MTP3MSUDiscardedRtDataErrTotal OBJECT-TYPE
+ SYNTAX Integer32 (-1..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total since last reset."
+ ::= {acPMSS7MTP3MSUDiscardedRtDataErrEntry 4}
+
+
+
+ -- ****************************************
+ -- acPMSS7RxMTP3TFCMsg table declaration
+ -- ****************************************
+ acPMSS7RxMTP3TFCMsgTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AcPMSS7RxMTP3TFCMsgEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Number of MTP3 TFC messages received per SS7 MTP3 node "
+ ::= {acPMSS7SignalingNodes 9}
+
+
+
+ -- ****************************************
+ -- acPMSS7RxMTP3TFCMsg table entry
+ -- ****************************************
+ acPMSS7RxMTP3TFCMsgEntry OBJECT-TYPE
+ SYNTAX AcPMSS7RxMTP3TFCMsgEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX {acPMSS7RxMTP3TFCMsgSN,acPMSS7RxMTP3TFCMsgInterval}
+ ::= {acPMSS7RxMTP3TFCMsgTable 1}
+
+
+
+ -- ****************************************
+ -- acPMSS7RxMTP3TFCMsg TABLE
+ -- ****************************************
+ AcPMSS7RxMTP3TFCMsgEntry ::= SEQUENCE {
+ acPMSS7RxMTP3TFCMsgSN Unsigned32,
+ acPMSS7RxMTP3TFCMsgInterval Unsigned32,
+ acPMSS7RxMTP3TFCMsgVal Counter32,
+ acPMSS7RxMTP3TFCMsgTotal Integer32
+ }
+
+
+
+ acPMSS7RxMTP3TFCMsgSN OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "SN number.
+0 is the first SN."
+ ::= {acPMSS7RxMTP3TFCMsgEntry 1}
+
+
+
+ acPMSS7RxMTP3TFCMsgInterval OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Interval index.
+0 - current period (incomplete monitoring - mid period).
+1 - Last full period.
+2 - One before last."
+ ::= {acPMSS7RxMTP3TFCMsgEntry 2}
+
+
+
+ acPMSS7RxMTP3TFCMsgVal OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Value of gauge or counter."
+ ::= {acPMSS7RxMTP3TFCMsgEntry 3}
+
+
+
+ acPMSS7RxMTP3TFCMsgTotal OBJECT-TYPE
+ SYNTAX Integer32 (-1..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total since last reset."
+ ::= {acPMSS7RxMTP3TFCMsgEntry 4}
+
+
+
+ acPMSS7MPT2Timers OBJECT IDENTIFIER ::= {acPMSS7Data 61}
+
+
+ -- ****************************************
+ -- acPMSS7MTP2T1Expiry table declaration
+ -- ****************************************
+ acPMSS7MTP2T1ExpiryTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AcPMSS7MTP2T1ExpiryEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Number of MTP2 T1 expiry per SS7 link"
+ ::= {acPMSS7MPT2Timers 1}
+
+
+
+ -- ****************************************
+ -- acPMSS7MTP2T1Expiry table entry
+ -- ****************************************
+ acPMSS7MTP2T1ExpiryEntry OBJECT-TYPE
+ SYNTAX AcPMSS7MTP2T1ExpiryEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX {acPMSS7MTP2T1ExpiryLink,acPMSS7MTP2T1ExpiryInterval}
+ ::= {acPMSS7MTP2T1ExpiryTable 1}
+
+
+
+ -- ****************************************
+ -- acPMSS7MTP2T1Expiry TABLE
+ -- ****************************************
+ AcPMSS7MTP2T1ExpiryEntry ::= SEQUENCE {
+ acPMSS7MTP2T1ExpiryLink Unsigned32,
+ acPMSS7MTP2T1ExpiryInterval Unsigned32,
+ acPMSS7MTP2T1ExpiryVal Counter32,
+ acPMSS7MTP2T1ExpiryTotal Integer32
+ }
+
+
+
+ acPMSS7MTP2T1ExpiryLink OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Link number.
+0 is the first link."
+ ::= {acPMSS7MTP2T1ExpiryEntry 1}
+
+
+
+ acPMSS7MTP2T1ExpiryInterval OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Interval index.
+0 - current period (incomplete monitoring - mid period).
+1 - Last full period.
+2 - One before last."
+ ::= {acPMSS7MTP2T1ExpiryEntry 2}
+
+
+
+ acPMSS7MTP2T1ExpiryVal OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Value of gauge or counter."
+ ::= {acPMSS7MTP2T1ExpiryEntry 3}
+
+
+
+ acPMSS7MTP2T1ExpiryTotal OBJECT-TYPE
+ SYNTAX Integer32 (-1..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total since last reset."
+ ::= {acPMSS7MTP2T1ExpiryEntry 4}
+
+
+
+ -- ****************************************
+ -- acPMSS7MTP2T2Expiry table declaration
+ -- ****************************************
+ acPMSS7MTP2T2ExpiryTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AcPMSS7MTP2T2ExpiryEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Number of MTP2 T2 expiry per SS7 link"
+ ::= {acPMSS7MPT2Timers 2}
+
+
+
+ -- ****************************************
+ -- acPMSS7MTP2T2Expiry table entry
+ -- ****************************************
+ acPMSS7MTP2T2ExpiryEntry OBJECT-TYPE
+ SYNTAX AcPMSS7MTP2T2ExpiryEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX {acPMSS7MTP2T2ExpiryLink,acPMSS7MTP2T2ExpiryInterval}
+ ::= {acPMSS7MTP2T2ExpiryTable 1}
+
+
+
+ -- ****************************************
+ -- acPMSS7MTP2T2Expiry TABLE
+ -- ****************************************
+ AcPMSS7MTP2T2ExpiryEntry ::= SEQUENCE {
+ acPMSS7MTP2T2ExpiryLink Unsigned32,
+ acPMSS7MTP2T2ExpiryInterval Unsigned32,
+ acPMSS7MTP2T2ExpiryVal Counter32,
+ acPMSS7MTP2T2ExpiryTotal Integer32
+ }
+
+
+
+ acPMSS7MTP2T2ExpiryLink OBJECT-TYPE
+ SYNTAX Unsigned32 (0..63)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Link number.
+0 is the first link."
+ ::= {acPMSS7MTP2T2ExpiryEntry 1}
+
+
+
+ acPMSS7MTP2T2ExpiryInterval OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Interval index.
+0 - current period (incomplete monitoring - mid period).
+1 - Last full period.
+2 - One before last."
+ ::= {acPMSS7MTP2T2ExpiryEntry 2}
+
+
+
+ acPMSS7MTP2T2ExpiryVal OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Value of gauge or counter."
+ ::= {acPMSS7MTP2T2ExpiryEntry 3}
+
+
+
+ acPMSS7MTP2T2ExpiryTotal OBJECT-TYPE
+ SYNTAX Integer32 (-1..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total since last reset."
+ ::= {acPMSS7MTP2T2ExpiryEntry 4}
+
+
+
+ -- ****************************************
+ -- acPMSS7MTP2T3Expiry table declaration
+ -- ****************************************
+ acPMSS7MTP2T3ExpiryTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AcPMSS7MTP2T3ExpiryEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Number of MTP2 T3 expiry per SS7 link"
+ ::= {acPMSS7MPT2Timers 3}
+
+
+
+ -- ****************************************
+ -- acPMSS7MTP2T3Expiry table entry
+ -- ****************************************
+ acPMSS7MTP2T3ExpiryEntry OBJECT-TYPE
+ SYNTAX AcPMSS7MTP2T3ExpiryEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX {acPMSS7MTP2T3ExpiryLink,acPMSS7MTP2T3ExpiryInterval}
+ ::= {acPMSS7MTP2T3ExpiryTable 1}
+
+
+
+ -- ****************************************
+ -- acPMSS7MTP2T3Expiry TABLE
+ -- ****************************************
+ AcPMSS7MTP2T3ExpiryEntry ::= SEQUENCE {
+ acPMSS7MTP2T3ExpiryLink Unsigned32,
+ acPMSS7MTP2T3ExpiryInterval Unsigned32,
+ acPMSS7MTP2T3ExpiryVal Counter32,
+ acPMSS7MTP2T3ExpiryTotal Integer32
+ }
+
+
+
+ acPMSS7MTP2T3ExpiryLink OBJECT-TYPE
+ SYNTAX Unsigned32 (0..63)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Link number.
+0 is the first link."
+ ::= {acPMSS7MTP2T3ExpiryEntry 1}
+
+
+
+ acPMSS7MTP2T3ExpiryInterval OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Interval index.
+0 - current period (incomplete monitoring - mid period).
+1 - Last full period.
+2 - One before last."
+ ::= {acPMSS7MTP2T3ExpiryEntry 2}
+
+
+
+ acPMSS7MTP2T3ExpiryVal OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Value of gauge or counter."
+ ::= {acPMSS7MTP2T3ExpiryEntry 3}
+
+
+
+ acPMSS7MTP2T3ExpiryTotal OBJECT-TYPE
+ SYNTAX Integer32 (-1..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total since last reset."
+ ::= {acPMSS7MTP2T3ExpiryEntry 4}
+
+
+
+ -- ****************************************
+ -- acPMSS7MTP2T4Expiry table declaration
+ -- ****************************************
+ acPMSS7MTP2T4ExpiryTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AcPMSS7MTP2T4ExpiryEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Number of MTP2 T4 expiry per SS7 link"
+ ::= {acPMSS7MPT2Timers 4}
+
+
+
+ -- ****************************************
+ -- acPMSS7MTP2T4Expiry table entry
+ -- ****************************************
+ acPMSS7MTP2T4ExpiryEntry OBJECT-TYPE
+ SYNTAX AcPMSS7MTP2T4ExpiryEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX {acPMSS7MTP2T4ExpiryLink,acPMSS7MTP2T4ExpiryInterval}
+ ::= {acPMSS7MTP2T4ExpiryTable 1}
+
+
+
+ -- ****************************************
+ -- acPMSS7MTP2T4Expiry TABLE
+ -- ****************************************
+ AcPMSS7MTP2T4ExpiryEntry ::= SEQUENCE {
+ acPMSS7MTP2T4ExpiryLink Unsigned32,
+ acPMSS7MTP2T4ExpiryInterval Unsigned32,
+ acPMSS7MTP2T4ExpiryVal Counter32,
+ acPMSS7MTP2T4ExpiryTotal Integer32
+ }
+
+
+
+ acPMSS7MTP2T4ExpiryLink OBJECT-TYPE
+ SYNTAX Unsigned32 (0..63)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Link number.
+0 is the first link."
+ ::= {acPMSS7MTP2T4ExpiryEntry 1}
+
+
+
+ acPMSS7MTP2T4ExpiryInterval OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Interval index.
+0 - current period (incomplete monitoring - mid period).
+1 - Last full period.
+2 - One before last."
+ ::= {acPMSS7MTP2T4ExpiryEntry 2}
+
+
+
+ acPMSS7MTP2T4ExpiryVal OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Value of gauge or counter."
+ ::= {acPMSS7MTP2T4ExpiryEntry 3}
+
+
+
+ acPMSS7MTP2T4ExpiryTotal OBJECT-TYPE
+ SYNTAX Integer32 (-1..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total since last reset."
+ ::= {acPMSS7MTP2T4ExpiryEntry 4}
+
+
+
+ -- ****************************************
+ -- acPMSS7MTP2T5Expiry table declaration
+ -- ****************************************
+ acPMSS7MTP2T5ExpiryTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AcPMSS7MTP2T5ExpiryEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Number of MTP2 T5 expiry per SS7 link"
+ ::= {acPMSS7MPT2Timers 5}
+
+
+
+ -- ****************************************
+ -- acPMSS7MTP2T5Expiry table entry
+ -- ****************************************
+ acPMSS7MTP2T5ExpiryEntry OBJECT-TYPE
+ SYNTAX AcPMSS7MTP2T5ExpiryEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX {acPMSS7MTP2T5ExpiryLink,acPMSS7MTP2T5ExpiryInterval}
+ ::= {acPMSS7MTP2T5ExpiryTable 1}
+
+
+
+ -- ****************************************
+ -- acPMSS7MTP2T5Expiry TABLE
+ -- ****************************************
+ AcPMSS7MTP2T5ExpiryEntry ::= SEQUENCE {
+ acPMSS7MTP2T5ExpiryLink Unsigned32,
+ acPMSS7MTP2T5ExpiryInterval Unsigned32,
+ acPMSS7MTP2T5ExpiryVal Counter32,
+ acPMSS7MTP2T5ExpiryTotal Integer32
+ }
+
+
+
+ acPMSS7MTP2T5ExpiryLink OBJECT-TYPE
+ SYNTAX Unsigned32 (0..63)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Link number.
+0 is the first link."
+ ::= {acPMSS7MTP2T5ExpiryEntry 1}
+
+
+
+ acPMSS7MTP2T5ExpiryInterval OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Interval index.
+0 - current period (incomplete monitoring - mid period).
+1 - Last full period.
+2 - One before last."
+ ::= {acPMSS7MTP2T5ExpiryEntry 2}
+
+
+
+ acPMSS7MTP2T5ExpiryVal OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Value of gauge or counter."
+ ::= {acPMSS7MTP2T5ExpiryEntry 3}
+
+
+
+ acPMSS7MTP2T5ExpiryTotal OBJECT-TYPE
+ SYNTAX Integer32 (-1..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total since last reset."
+ ::= {acPMSS7MTP2T5ExpiryEntry 4}
+
+
+
+ -- ****************************************
+ -- acPMSS7MTP2T6Expiry table declaration
+ -- ****************************************
+ acPMSS7MTP2T6ExpiryTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AcPMSS7MTP2T6ExpiryEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Number of MTP2 T6 expiry per SS7 link"
+ ::= {acPMSS7MPT2Timers 6}
+
+
+
+ -- ****************************************
+ -- acPMSS7MTP2T6Expiry table entry
+ -- ****************************************
+ acPMSS7MTP2T6ExpiryEntry OBJECT-TYPE
+ SYNTAX AcPMSS7MTP2T6ExpiryEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX {acPMSS7MTP2T6ExpiryLink,acPMSS7MTP2T6ExpiryInterval}
+ ::= {acPMSS7MTP2T6ExpiryTable 1}
+
+
+
+ -- ****************************************
+ -- acPMSS7MTP2T6Expiry TABLE
+ -- ****************************************
+ AcPMSS7MTP2T6ExpiryEntry ::= SEQUENCE {
+ acPMSS7MTP2T6ExpiryLink Unsigned32,
+ acPMSS7MTP2T6ExpiryInterval Unsigned32,
+ acPMSS7MTP2T6ExpiryVal Counter32,
+ acPMSS7MTP2T6ExpiryTotal Integer32
+ }
+
+
+
+ acPMSS7MTP2T6ExpiryLink OBJECT-TYPE
+ SYNTAX Unsigned32 (0..63)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Link number.
+0 is the first link."
+ ::= {acPMSS7MTP2T6ExpiryEntry 1}
+
+
+
+ acPMSS7MTP2T6ExpiryInterval OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Interval index.
+0 - current period (incomplete monitoring - mid period).
+1 - Last full period.
+2 - One before last."
+ ::= {acPMSS7MTP2T6ExpiryEntry 2}
+
+
+
+ acPMSS7MTP2T6ExpiryVal OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Value of gauge or counter."
+ ::= {acPMSS7MTP2T6ExpiryEntry 3}
+
+
+
+ acPMSS7MTP2T6ExpiryTotal OBJECT-TYPE
+ SYNTAX Integer32 (-1..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total since last reset."
+ ::= {acPMSS7MTP2T6ExpiryEntry 4}
+
+
+
+ -- ****************************************
+ -- acPMSS7MTP2T7Expiry table declaration
+ -- ****************************************
+ acPMSS7MTP2T7ExpiryTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AcPMSS7MTP2T7ExpiryEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Number of MTP2 T7 expiry per SS7 link"
+ ::= {acPMSS7MPT2Timers 7}
+
+
+
+ -- ****************************************
+ -- acPMSS7MTP2T7Expiry table entry
+ -- ****************************************
+ acPMSS7MTP2T7ExpiryEntry OBJECT-TYPE
+ SYNTAX AcPMSS7MTP2T7ExpiryEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX {acPMSS7MTP2T7ExpiryLink,acPMSS7MTP2T7ExpiryInterval}
+ ::= {acPMSS7MTP2T7ExpiryTable 1}
+
+
+
+ -- ****************************************
+ -- acPMSS7MTP2T7Expiry TABLE
+ -- ****************************************
+ AcPMSS7MTP2T7ExpiryEntry ::= SEQUENCE {
+ acPMSS7MTP2T7ExpiryLink Unsigned32,
+ acPMSS7MTP2T7ExpiryInterval Unsigned32,
+ acPMSS7MTP2T7ExpiryVal Counter32,
+ acPMSS7MTP2T7ExpiryTotal Integer32
+ }
+
+
+
+ acPMSS7MTP2T7ExpiryLink OBJECT-TYPE
+ SYNTAX Unsigned32 (0..63)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Link number.
+0 is the first link."
+ ::= {acPMSS7MTP2T7ExpiryEntry 1}
+
+
+
+ acPMSS7MTP2T7ExpiryInterval OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Interval index.
+0 - current period (incomplete monitoring - mid period).
+1 - Last full period.
+2 - One before last."
+ ::= {acPMSS7MTP2T7ExpiryEntry 2}
+
+
+
+ acPMSS7MTP2T7ExpiryVal OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Value of gauge or counter."
+ ::= {acPMSS7MTP2T7ExpiryEntry 3}
+
+
+
+ acPMSS7MTP2T7ExpiryTotal OBJECT-TYPE
+ SYNTAX Integer32 (-1..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total since last reset."
+ ::= {acPMSS7MTP2T7ExpiryEntry 4}
+
+
+
+
+
+END
|