diff options
| author | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
|---|---|---|
| committer | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
| commit | 98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch) | |
| tree | 9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/avocent/ACS-MIB | |
| download | mibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.tar.gz mibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.zip | |
Diffstat (limited to 'MIBS/avocent/ACS-MIB')
| -rw-r--r-- | MIBS/avocent/ACS-MIB | 2572 |
1 files changed, 2572 insertions, 0 deletions
diff --git a/MIBS/avocent/ACS-MIB b/MIBS/avocent/ACS-MIB new file mode 100644 index 0000000..9587a10 --- /dev/null +++ b/MIBS/avocent/ACS-MIB @@ -0,0 +1,2572 @@ +-------------------------------------------------------------------------------- +-- Avocent ACS MIB +-- Copyright 2009 Avocent Corporation +-- Revision: 2.0.1 +-- Last Modified: October 10, 2010 +-------------------------------------------------------------------------------- + +ACS-MIB DEFINITIONS ::= BEGIN + +IMPORTS + Gauge,TimeTicks,IpAddress,Counter,NetworkAddress + FROM RFC1155-SMI + PhysAddress + FROM RFC1213-MIB + enterprises, MODULE-IDENTITY + FROM SNMPv2-SMI + OBJECT-TYPE, MODULE-IDENTITY, OBJECT-IDENTITY, Integer32 + FROM SNMPv2-SMI + DisplayString + FROM SNMPv2-TC + InterfaceIndex, InterfaceIndexOrZero + FROM IF-MIB + TRAP-TYPE + FROM RFC-1215; + +-------------------------------------------------------------------------------- +-- Object Groupings +-------------------------------------------------------------------------------- + +--@ Note: every product type should be uniquely identified underneath the +--@ acsProducts object group. Each product should report its unique acsProducts +--@ OBJECT IDENTIFIER in mib-2.system.sysObjectID. Please see the file +--@ "_Avocent Enterprise Object Identifier Assignment.txt" for a list of the +--@ IDs that have been assigned. + +-- enterprises .1.3.6.1.4.1 + +-- avocent OBJECT IDENTIFIER ::= { enterprises 10418 } + +acs MODULE-IDENTITY + LAST-UPDATED "201010100000Z" + ORGANIZATION "Avocent Corporation" + CONTACT-INFO "postal : Avocent Corporation + 47281 Bayside Parkway + Fremont, CA 94538, USA + e-mail : Technical Support + techsupport@avocent.com" + DESCRIPTION + "This module defines the Avocent MIB extensions to + ACS60xx products." + REVISION "201010100000Z" + DESCRIPTION "Add products acs6004 and acs6008" + REVISION "200912110000Z" + DESCRIPTION "Extended acsPowerMgmt to support data monitoring + and Avocent PM-PDUs" + REVISION "200709170000Z" + DESCRIPTION "First Draft" +::= { enterprises 10418 16 } + +acsProducts OBJECT IDENTIFIER ::= { acs 1 } +acsManagement OBJECT IDENTIFIER ::= { acs 2 } +-- +acs6016 OBJECT IDENTIFIER ::= { acsProducts 1 } -- 10418.16.1.1 +acs6032 OBJECT IDENTIFIER ::= { acsProducts 2 } -- 10418.16.1.2 +acs6048 OBJECT IDENTIFIER ::= { acsProducts 3 } -- 10418.16.1.3 +acs6004 OBJECT IDENTIFIER ::= { acsProducts 4 } -- 10418.16.1.4 +acs6008 OBJECT IDENTIFIER ::= { acsProducts 5 } -- 10418.16.1.5 + +acsAppliance OBJECT IDENTIFIER ::= { acsManagement 1 } -- 10418.16.2.1 +acsSessions OBJECT IDENTIFIER ::= { acsManagement 2 } -- 10418.16.2.2 +acsSerialPort OBJECT IDENTIFIER ::= { acsManagement 3 } -- 10418.16.2.3 +acsPowerMgmt OBJECT IDENTIFIER ::= { acsManagement 5 } -- 10418.16.2.5 + +-- objects under acsPowerMgmt +-- acsPowerMgmtNumSerialPorts ::= { acsPowerMgmt 1 } +-- acsPowerMgmtSerialTable ::= { acsPowerMgmt 2 } +-- acsPowerMgmtPDUTable ::= { acsPowerMgmt 3 } +-- acsPowerMgmtTotalNumberOfOutlets ::= { acsPowerMgmt 4 } +-- acsPowerMgmtOutletsTable ::= { acsPowerMgmt 5 } +-- acsPowerMgmtNumberOfOutletGroup ::= { acsPowerMgmt 6 } +-- acsPowerMgmtGroupTable ::= { acsPowerMgmt 7 } +-- acsPowerMgmtPhasesTable ::= { acsPowerMgmt 8 } +-- acsPowerMgmtBanksTable ::= { acsPowerMgmt 9 } +-- acsPowerMgmtEnvMonTable ::= { acsPowerMgmt 10 } +-- acsPowerMgmtOutElecMonTable ::= { acsPowerMgmt 11 } + + +-- +-- Note that traps are defined in a separate trap MIB +-- +acsTrapObject OBJECT IDENTIFIER ::= { acsManagement 6 } -- 10418.16.2.6 + +-- +-- Type Definitions +-- + +-- +-- Each enumeration represents the states of the appliance power supplies. +PowerSupplyState ::= INTEGER +{ + statePowerOn(1), + statePowerOff(2), + powerNotInstaled(9999) +} + +-- +-- Each enumeration represents the speed of the serial port. +SerialPortSpeed ::= INTEGER +{ + speed300bps(300), + speed600bps(600), + speed1200bps(1200), + speed2400bps(2400), + speed4800bps(4800), + speed9600bps(9600), + speed19200bps(19200), + speed38400bps(38400), + speed57600bps(57600), + speed115200bps(115200), + speed230400bps(230400), + speed460800bps(460800) +} + +-- +-- Each enumeration represents the state of the RS-232C signal. +SerialPortSignalState ::=INTEGER +{ + up(1), + down(2) +} + +-- +-- Each enumeration represents the RJ-45 pin-out +SerialPortPinOut ::=INTEGER +{ + cyclades(1), + cisco(2) +} + +-- +-- acsAppliance +-- OBJECT IDENTIFIER ::= { acsManagement 1 } 10418.16.2.1 +-- +acsHostName OBJECT-TYPE + SYNTAX DisplayString ( SIZE (0..32) ) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The appliance name" +::= { acsAppliance 1 } + +acsProductModel OBJECT-TYPE + SYNTAX DisplayString ( SIZE (0..50) ) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The appliance product model" +::= { acsAppliance 2 } + +acsPartNumber OBJECT-TYPE + SYNTAX DisplayString ( SIZE (0..32) ) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The part number of this appliance as shown on the label + attached or imprinted on the appliance." +::= { acsAppliance 3 } + +acsSerialNumber OBJECT-TYPE + SYNTAX DisplayString ( SIZE (0..32) ) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The serial number of this appliance as shown on the label + attached or imprinted on the appliance." +::= { acsAppliance 4 } + +acsEIDNumber OBJECT-TYPE + SYNTAX DisplayString ( SIZE (0..32) ) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The electronic ID number (EID) of this appliance as shown on the label + attached or imprinted on the appliance." +::= { acsAppliance 5 } + +acsBootcodeVersion OBJECT-TYPE + SYNTAX DisplayString ( SIZE (0..32) ) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The version of the bootcode of this appliance." +::= { acsAppliance 6 } + +acsFirmwareVersion OBJECT-TYPE + SYNTAX DisplayString ( SIZE (0..32) ) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The version of the firmware of this appliance." +::= { acsAppliance 7 } + +acsPowerSupply OBJECT-IDENTITY + STATUS current + DESCRIPTION + "It gives information about Power Supply of this appliance" +::= { acsAppliance 8 } + +acsPowerSupplyNumber OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of the power supplies of this appliance" +::= { acsPowerSupply 1 } + +acsPowerSupplyStatePw1 OBJECT-TYPE + SYNTAX PowerSupplyState + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "State of the first power supply" +::= { acsPowerSupply 2 } + +acsPowerSupplyStatePw2 OBJECT-TYPE + SYNTAX PowerSupplyState + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "State of the second power supply" +::= { acsPowerSupply 3 } + +acsReboot OBJECT-TYPE + SYNTAX INTEGER { + noAction(1), + reboot(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "A set value of reboot(2) will reboot the appliance. + noAction(1) = always returned in a GET. Does nothing if SET. + reboot(2) = when SET the appliance immediately reboots." +::= { acsAppliance 9 } + +-- +-- acsSessions +-- OBJECT IDENTIFIER ::= { acsManagement 2 } 10418.16.2.2 +-- +acsActiveSessionsNumberOfSession OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of active sessions." +::= { acsSessions 1 } + +acsActiveSessionsTable OBJECT-TYPE + SYNTAX SEQUENCE OF AcsActiveSessionsTableEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table contains the list of active sessions." +::= { acsSessions 2 } + +acsActiveSessionsTableEntry OBJECT-TYPE + SYNTAX AcsActiveSessionsTableEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "each entry has the information about the active session" + INDEX { acsActiveSessionsTableIndex } +::= { acsActiveSessionsTable 1 } + +AcsActiveSessionsTableEntry ::= SEQUENCE { + acsActiveSessionsTableIndex InterfaceIndexOrZero, + acsActiveSessionsTableUser DisplayString, -- user name + acsActiveSessionsTableGroup DisplayString, -- group name + acsActiveSessionsTableType DisplayString, -- RO/RW-ssh,telnet or web + acsActiveSessionsTableConnection DisplayString, -- type + target name + acsActiveSessionsTableSessionTime DisplayString, -- time of session + acsActiveSessionsTableFrom DisplayString, -- source of the session + acsActiveSessionsTableKill INTEGER +} + +acsActiveSessionsTableIndex OBJECT-TYPE + SYNTAX InterfaceIndexOrZero + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A unique index representing an entry in this table." +::= { acsActiveSessionsTableEntry 1 } + +acsActiveSessionsTableUser OBJECT-TYPE + SYNTAX DisplayString ( SIZE (0..32) ) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The name of the user that opens this session." +::= { acsActiveSessionsTableEntry 2 } + +acsActiveSessionsTableGroup OBJECT-TYPE + SYNTAX DisplayString ( SIZE (0..32) ) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The name of the group that the user belongs to." +::= { acsActiveSessionsTableEntry 3 } + +acsActiveSessionsTableType OBJECT-TYPE + SYNTAX DisplayString ( SIZE (0..32) ) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The session type." +::= { acsActiveSessionsTableEntry 4 } + +acsActiveSessionsTableConnection OBJECT-TYPE + SYNTAX DisplayString ( SIZE (0..32) ) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Connection type." +::= { acsActiveSessionsTableEntry 5 } + +acsActiveSessionsTableSessionTime OBJECT-TYPE + SYNTAX DisplayString ( SIZE (0..32) ) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Time of the session" +::= { acsActiveSessionsTableEntry 6 } + +acsActiveSessionsTableFrom OBJECT-TYPE + SYNTAX DisplayString ( SIZE (0..32) ) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The source IP address of the session." +::= { acsActiveSessionsTableEntry 7 } + +acsActiveSessionsTableKill OBJECT-TYPE + SYNTAX INTEGER { + noAction(1), + killSession(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "A set value of killSession(2) will kill the session. + noAction(1) = always returned in a GET. Does nothing if SET. + killSession(2)= when SET the appliance immediately kills the session." +::= { acsActiveSessionsTableEntry 8 } + +-- +-- acsSerialPort +-- OBJECT IDENTIFIER ::= { acsManagement 3 } 10418.16.2.3 +-- + +acsSerialPortNumberOfPorts OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of Serial Ports (physical serial port plus Aux Port." +::= { acsSerialPort 1 } + +acsSerialPortTable OBJECT-TYPE + SYNTAX SEQUENCE OF AcsSerialPortTableEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table contains information about serial ports." +::= { acsSerialPort 2 } + +acsSerialPortTableEntry OBJECT-TYPE + SYNTAX AcsSerialPortTableEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "each entry has the information about specific serial port." + INDEX { acsSerialPortTableNumber } +::= { acsSerialPortTable 1 } + +AcsSerialPortTableEntry ::= SEQUENCE { + acsSerialPortTableNumber Integer32, -- serial port number + acsSerialPortTableDeviceName DisplayString, -- associated device name + acsSerialPortTableStatus INTEGER, -- status of serial port + acsSerialPortTableName DisplayString, -- associated name + acsSerialPortTableProfile INTEGER, -- configured profile + acsSerialPortTablePinOut SerialPortPinOut, -- configure RJ45 pin-out + acsSerialPortTableComSpeed SerialPortSpeed, -- configured speed + acsSerialPortTableComParity INTEGER, -- configured parity + acsSerialPortTableComDataSize Integer32, -- configured data size + acsSerialPortTableComStopBits Integer32, -- configured stop bits + acsSerialPortTableComFlowControl INTEGER, -- configured flow control + acsSerialPortTableSignalStateDTR SerialPortSignalState, -- state of DTR RS-232C signal + acsSerialPortTableSignalStateDCD SerialPortSignalState, -- state of DCD RS-232C signal + acsSerialPortTableSignalStateRTS SerialPortSignalState, -- state of RTS RS-232C signal + acsSerialPortTableSignalStateCTS SerialPortSignalState, -- state of CTS RS-232C signal + acsSerialPortTableTxBytes Integer32, -- number of transmitted bytes + acsSerialPortTableRxBytes Integer32, -- number of received bytes + acsSerialPortTableFrameError Integer32, -- number of detected frame errors + acsSerialPortTableParityError Integer32, -- number of detected parity errors + acsSerialPortTableBreak Integer32, -- number of detected break + acsSerialPortTableOverrun Integer32 -- number of detected overrun errors +} + +acsSerialPortTableNumber OBJECT-TYPE + SYNTAX Integer32 (1..49) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A unique index representing an entry in this table. + It is the number of the serial port. For AUX port, + the number will be the number of physical serial ports plus 1." +::= { acsSerialPortTableEntry 1 } + +acsSerialPortTableDeviceName OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..25)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The associated device name for the serial port." +::= { acsSerialPortTableEntry 2 } + +acsSerialPortTableStatus OBJECT-TYPE + SYNTAX INTEGER { + disabled(1), + idle(2), + inUse(3) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The status of the serial port: + disabled(1) = it was configured as disable. + idle(2) = there is not any session opened in this port. + inUse(3) = there is session(s) opened in this port." +::= { acsSerialPortTableEntry 3 } + +acsSerialPortTableName OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..25)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Name associated with this serial port." +::= { acsSerialPortTableEntry 4 } + +acsSerialPortTableProfile OBJECT-TYPE + SYNTAX INTEGER { + casProfile(1), + tsProfile(2), + dialInProfile(3), + powerProfile(4) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Configured profile for this serial port." +::= { acsSerialPortTableEntry 5 } + +acsSerialPortTablePinOut OBJECT-TYPE + SYNTAX SerialPortPinOut + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "RJ45 Pin-out configured for this serial port." +::= { acsSerialPortTableEntry 6 } + +acsSerialPortTableComSpeed OBJECT-TYPE + SYNTAX SerialPortSpeed + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Speed configured for this serial port." +::= { acsSerialPortTableEntry 7 } + +acsSerialPortTableComParity OBJECT-TYPE + SYNTAX INTEGER { + none(1), + odd(2), + even(3) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Parity configured for this serial port." +::= { acsSerialPortTableEntry 8 } + +acsSerialPortTableComDataSize OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Data Size configured for this serial port." +::= { acsSerialPortTableEntry 9 } + +acsSerialPortTableComStopBits OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of Stop Bits configured for this serial port." +::= { acsSerialPortTableEntry 10 } + +acsSerialPortTableComFlowControl OBJECT-TYPE + SYNTAX INTEGER { + none(1), + hardware(2), + software(3) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Flow Control configured for this serial port." +::= { acsSerialPortTableEntry 11 } + +acsSerialPortTableSignalStateDTR OBJECT-TYPE + SYNTAX SerialPortSignalState + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "State of the DTR RS-232C signal." +::= { acsSerialPortTableEntry 12 } + +acsSerialPortTableSignalStateDCD OBJECT-TYPE + SYNTAX SerialPortSignalState + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "State of the DCD RS-232C signal." +::= { acsSerialPortTableEntry 13 } + +acsSerialPortTableSignalStateRTS OBJECT-TYPE + SYNTAX SerialPortSignalState + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "State of the RTS RS-232C signal." +::= { acsSerialPortTableEntry 14 } + +acsSerialPortTableSignalStateCTS OBJECT-TYPE + SYNTAX SerialPortSignalState + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "State of the CTS RS-232C signal." +::= { acsSerialPortTableEntry 15 } + +acsSerialPortTableTxBytes OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of transmited bytes by the serial port." +::= { acsSerialPortTableEntry 16 } + +acsSerialPortTableRxBytes OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of received bytes by the serial port." +::= { acsSerialPortTableEntry 17 } + +acsSerialPortTableFrameError OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of frame error detected in the serial port." +::= { acsSerialPortTableEntry 18 } + +acsSerialPortTableParityError OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of parity error detected in the serial port." +::= { acsSerialPortTableEntry 19 } + +acsSerialPortTableBreak OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of break detected in the serial port." +::= { acsSerialPortTableEntry 20 } + +acsSerialPortTableOverrun OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of overrun error detected in the serial port." +::= { acsSerialPortTableEntry 21 } + +-- +-- acsPowerMgmt +-- OBJECT IDENTIFIER ::= { acsManagement 5 } 10418.16.2.5 +-- +acsPowerMgmtNumSerialPorts OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Serial Ports that has PDU connected on the appliance." +::= { acsPowerMgmt 1 } + +acsPowerMgmtSerialTable OBJECT-TYPE + SYNTAX SEQUENCE OF AcsPowerMgmtSerialTableEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Information about each serial port thas has PDU connect." +::= { acsPowerMgmt 2 } + +acsPowerMgmtSerialTableEntry OBJECT-TYPE + SYNTAX AcsPowerMgmtSerialTableEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Information about each serial port thas has PDU connect." + INDEX { acsPowerMgmtSerialTableIndex } +::= { acsPowerMgmtSerialTable 1 } + +AcsPowerMgmtSerialTableEntry ::= SEQUENCE { + acsPowerMgmtSerialTableIndex InterfaceIndex, + acsPowerMgmtSerialTablePortNumber Integer32, + acsPowerMgmtSerialTableDeviceName DisplayString, + acsPowerMgmtSerialTableNumberPDUs Integer32 +} + +acsPowerMgmtSerialTableIndex OBJECT-TYPE + SYNTAX InterfaceIndex + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The index of the register." +::= { acsPowerMgmtSerialTableEntry 1 } + +acsPowerMgmtSerialTablePortNumber OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of the serial port when the PDU is connected." +::= { acsPowerMgmtSerialTableEntry 2 } + +acsPowerMgmtSerialTableDeviceName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The device name of this serial port." +::= { acsPowerMgmtSerialTableEntry 3 } + +acsPowerMgmtSerialTableNumberPDUs OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Total number of units connected in this serial port." +::= { acsPowerMgmtSerialTableEntry 4 } + +acsPowerMgmtPDUTable OBJECT-TYPE + SYNTAX SEQUENCE OF AcsPowerMgmtPDUTableEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table contains the list of detected PDUs." +::= { acsPowerMgmt 3 } + +acsPowerMgmtPDUTableEntry OBJECT-TYPE + SYNTAX AcsPowerMgmtPDUTableEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "each entry has the information about the PDU." + INDEX { acsPowerMgmtPDUTablePortNumber, acsPowerMgmtPDUTablePduIndex } +::= { acsPowerMgmtPDUTable 1 } + +AcsPowerMgmtPDUTableEntry ::= SEQUENCE { + acsPowerMgmtPDUTablePortNumber InterfaceIndex, -- number of serial port + acsPowerMgmtPDUTablePduIndex InterfaceIndexOrZero, + acsPowerMgmtPDUTablePduId DisplayString, -- PDU identification + acsPowerMgmtPDUTablePortName DisplayString, -- Serial Port Name + acsPowerMgmtPDUTableModel DisplayString, -- PDU model + acsPowerMgmtPDUTableVendor DisplayString, -- Vendor + acsPowerMgmtPDUTableFirmwareVersion DisplayString, -- Firmware Version + acsPowerMgmtPDUTableNumberOfOutlets Integer32, + acsPowerMgmtPDUTableCurrentNOS Integer32, -- OBSOLETED number of current sensors + acsPowerMgmtPDUTableCurrent1Value Integer32, -- OBSOLETED actual value for current of the sensor 1 + acsPowerMgmtPDUTableCurrent1Max Integer32, -- OBSOLETED max value for current of the sensor 1 + acsPowerMgmtPDUTableCurrent2Value Integer32, -- OBSOLETED actual value for current of the sensor 2 + acsPowerMgmtPDUTableCurrent2Max Integer32, -- OBSOLETED max value for current of the sensor 2 + acsPowerMgmtPDUTableCurrent3Value Integer32, -- OBSOLETED actual value for current of the sensor 3 + acsPowerMgmtPDUTableCurrent3Max Integer32, -- OBSOLETED max value for current of the sensor 3 + acsPowerMgmtPDUTableTemperatureNOS Integer32, -- OBSOLETED number of temperature sensors + acsPowerMgmtPDUTableTemperature1Value Integer32, -- OBSOLETED actual value for Temperature 1 + acsPowerMgmtPDUTableTemperature1Max Integer32, -- OBSOLETED max value for Temperature 1 + acsPowerMgmtPDUTableTemperature2Value Integer32, -- OBSOLETED actual value for Temperaturet 2 + acsPowerMgmtPDUTableTemperature2Max Integer32, -- OBSOLETED max value for Temperature 2 + acsPowerMgmtPDUTableTemperature3Value Integer32, -- OBSOLETED actual value for Temperature 3 + acsPowerMgmtPDUTableTemperature3Max Integer32, -- OBSOLETED max value for Temperature 3 + acsPowerMgmtPDUTableHumidityNOS Integer32, -- OBSOLETED humidity number of humidity sensors + acsPowerMgmtPDUTableHumidity1Value Integer32, -- OBSOLETED actual value for Humidity of the sensor 1 + acsPowerMgmtPDUTableHumidity1Max Integer32, -- OBSOLETED max value for Humidityof the sensor 1 + acsPowerMgmtPDUTableHumidity2Value Integer32, -- OBSOLETED actual value for Humidity of the sensor 2 + acsPowerMgmtPDUTableHumidity2Max Integer32, -- OBSOLETED max value for Humidity of the sensor 2 + acsPowerMgmtPDUTableHumidity3Value Integer32, -- OBSOLETED actual value for Humidity of the sensor 3 + acsPowerMgmtPDUTableHumidity3Max Integer32, -- OBSOLETED max value for Humidity of the sensor 3 + acsPowerMgmtPDUTableVoltageNOS Integer32, -- OBSOLETED number of voltage sensor + acsPowerMgmtPDUTableVoltage1Value Integer32, -- OBSOLETED actual value for Voltage of the sensor 1 + acsPowerMgmtPDUTableVoltage1Max Integer32, -- OBSOLETED max value for Voltage of the sensor 1 + acsPowerMgmtPDUTableVoltage2Value Integer32, -- OBSOLETED actual value for Voltage of the sensor 2 + acsPowerMgmtPDUTableVoltage2Max Integer32, -- OBSOLETED max value for Voltaget of the sensor 2 + acsPowerMgmtPDUTableVoltage3Value Integer32, -- OBSOLETED actual value for Voltage of the sensor 3 + acsPowerMgmtPDUTableVoltage3Max Integer32, -- OBSOLETED max value for Voltage of the sensor 3 + acsPowerMgmtPDUTableNumberOfPhases Integer32, -- number of phases (single or 3-phases) + acsPowerMgmtPDUTableNumberOfBanks Integer32, -- number of banks + acsPowerMgmtPDUTableCurrentValue Integer32, -- actual value of PDU current sensor + acsPowerMgmtPDUTableCurrentMax Integer32, -- max detected value of current sensor + acsPowerMgmtPDUTableCurrentMin Integer32, -- min detected value of current sensor + acsPowerMgmtPDUTableCurrentAvg Integer32, -- average value for current sensor + acsPowerMgmtPDUTableCurrentReset INTEGER, -- reset max, min and avg values + acsPowerMgmtPDUTableVoltageType INTEGER, -- type of PDU voltage + acsPowerMgmtPDUTableVoltageValue Integer32, -- actual value of PDU voltage + acsPowerMgmtPDUTableVoltageMax Integer32, -- max value of voltage sensor + acsPowerMgmtPDUTableVoltageMin Integer32, -- min value of voltage sensor + acsPowerMgmtPDUTableVoltageAvg Integer32, -- avg value of voltage sensor + acsPowerMgmtPDUTableVoltageReset INTEGER, -- reset max, min and avg values + acsPowerMgmtPDUTablePowerType INTEGER, -- type of PDU power consumption + acsPowerMgmtPDUTablePowerValue Integer32, -- actual value of PDU power consumption + acsPowerMgmtPDUTablePowerMax Integer32, -- max value + acsPowerMgmtPDUTablePowerMin Integer32, -- min value + acsPowerMgmtPDUTablePowerAvg Integer32, -- average value + acsPowerMgmtPDUTablePowerReset INTEGER, -- reset max, min and avg values + acsPowerMgmtPDUTablePowerFactorType INTEGER, -- type of PDU power factor + acsPowerMgmtPDUTablePowerFactorValue Integer32, -- actual value of PDU power factor + acsPowerMgmtPDUTablePowerFactorMax Integer32, -- max value for power factor + acsPowerMgmtPDUTablePowerFactorMin Integer32, -- min value for power factor + acsPowerMgmtPDUTablePowerFactorAvg Integer32, -- avg value for power factor + acsPowerMgmtPDUTablePowerFactorReset INTEGER, -- reset max, min and avg values + acsPowerMgmtPDUTableAlarm INTEGER, -- status of PDU alarm + acsPowerMgmtPDUTableEnvSensors Integer32 -- number of environmental sensors +} + +acsPowerMgmtPDUTablePortNumber OBJECT-TYPE + SYNTAX InterfaceIndex + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of serial port when the PDU is connected." +::= { acsPowerMgmtPDUTableEntry 1 } + +acsPowerMgmtPDUTablePduIndex OBJECT-TYPE + SYNTAX InterfaceIndexOrZero + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A PDU position in the chain." +::= { acsPowerMgmtPDUTableEntry 2 } + +acsPowerMgmtPDUTablePduId OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "PDU identification." +::= { acsPowerMgmtPDUTableEntry 3 } + +acsPowerMgmtPDUTablePortName OBJECT-TYPE + SYNTAX DisplayString + + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Name of serial port when the PDU is connected." +::= { acsPowerMgmtPDUTableEntry 4 } + +acsPowerMgmtPDUTableModel OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Model of the PDU." +::= { acsPowerMgmtPDUTableEntry 5 } + +acsPowerMgmtPDUTableVendor OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Vendor of the PDU." +::= { acsPowerMgmtPDUTableEntry 6 } + +acsPowerMgmtPDUTableFirmwareVersion OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Version of the PDU firmware." +::= { acsPowerMgmtPDUTableEntry 7 } + +acsPowerMgmtPDUTableNumberOfOutlets OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of outlets of the PDU." +::= { acsPowerMgmtPDUTableEntry 8 } + +acsPowerMgmtPDUTableCurrentNOS OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS obsolete + DESCRIPTION + "Number of current sensors in the PDU." +::= { acsPowerMgmtPDUTableEntry 9 } + +acsPowerMgmtPDUTableCurrent1Value OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS obsolete + DESCRIPTION + "Current of the sensor 1 in this PDU unit in AMP. + The value of this object is the actual current in + AMP * 10. You need to translate the readed value + (Ex. : value is 5, the current is 0.5 AMP.)" +::= { acsPowerMgmtPDUTableEntry 10 } + +acsPowerMgmtPDUTableCurrent1Max OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS obsolete + DESCRIPTION + "Maximum current of the sensor 1 in this PDU unit in AMP. + When the PDU does not have support for maximum value, + the value will be 0. + The value of this object is the actual current in + AMP * 10. You need to translate the readed value + (Ex. : value is 5, the current is 0.5 AMP.) + Clear this value, set it with Zero value." +::= { acsPowerMgmtPDUTableEntry 11 } + +acsPowerMgmtPDUTableCurrent2Value OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS obsolete + DESCRIPTION + "Current of the sensor 2 in this PDU unit in AMP. + The value of this object is the actual current in + AMP * 10. You need to translate the readed value + (Ex. : value is 5, the current is 0.5 AMP.)" +::= { acsPowerMgmtPDUTableEntry 12 } + +acsPowerMgmtPDUTableCurrent2Max OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS obsolete + DESCRIPTION + "Maximum current of the sensor 2 in this PDU unit in AMP. + When the PDU does not have support for maximum value, + the value will be 0. + The value of this object is the actual current in + AMP * 10. You need to translate the readed value + (Ex. : value is 5, the current is 0.5 AMP.) + Clear this value, set it with Zero value." +::= { acsPowerMgmtPDUTableEntry 13} + +acsPowerMgmtPDUTableCurrent3Value OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS obsolete + DESCRIPTION + "Current of the sensor 3 in this PDU unit in AMP. + The value of this object is the actual current in + AMP * 10. You need to translate the readed value + (Ex. : value is 5, the current is 0.5 AMP.)" +::= { acsPowerMgmtPDUTableEntry 14 } + +acsPowerMgmtPDUTableCurrent3Max OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS obsolete + DESCRIPTION + "Maximum current of the sensor 3 in this PDU unit in AMP. + When the PDU does not have support for maximum value, + the value will be 0. + The value of this object is the actual current in + AMP * 10. You need to translate the readed value + (Ex. : value is 5, the current is 0.5 AMP.) + Clear this value, set it with Zero value." +::= { acsPowerMgmtPDUTableEntry 15 } + +acsPowerMgmtPDUTableTemperatureNOS OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS obsolete + DESCRIPTION + "Number of temperature sensors in the PDU." +::= { acsPowerMgmtPDUTableEntry 16 } + +acsPowerMgmtPDUTableTemperature1Value OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS obsolete + DESCRIPTION + "Temperature of this PM unit in Celsius degrees. + The value of this object is the actual temperature in + degrees C * 10. You need to translate the readed value + (Ex. : value is 240, the temperature is 24 Celsius.) + If the temperature measurement is not installed this + value will be 0. + Valid values are 5 to 999 ( 0.5 to 99.9 Celsius)." +::= { acsPowerMgmtPDUTableEntry 17 } + +acsPowerMgmtPDUTableTemperature1Max OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS obsolete + DESCRIPTION + "Maximum temperature detected in this PM unit in Celsius degrees. + The value will be Zero when the PDU does not have support for maximum value. + The value of this object is the actual temperature in + degrees C * 10. You need to translate the readed value + (Ex. : value is 240, the temperature is 24 Celsius.) + If the temperature measurement is not installed this + value will be 0. + Valid values are 5 to 999 ( 0.5 to 99.9 Celsius). + Set with Zero value to clear the max. temperature." +::= { acsPowerMgmtPDUTableEntry 18 } + +acsPowerMgmtPDUTableTemperature2Value OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS obsolete + DESCRIPTION + "Temperature of this PM unit in Celsius degrees. + The value of this object is the actual temperature in + degrees C * 10. You need to translate the readed value + (Ex. : value is 240, the temperature is 24 Celsius.) + If the temperature measurement is not installed this + value will be 0. + Valid values are 5 to 999 ( 0.5 to 99.9 Celsius)." +::= { acsPowerMgmtPDUTableEntry 19 } + +acsPowerMgmtPDUTableTemperature2Max OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS obsolete + DESCRIPTION + "Maximum temperature detected in this PM unit in Celsius degrees. + The value will be Zero when the PDU does not have support for maximum value. + The value of this object is the actual temperature in + degrees C * 10. You need to translate the readed value + (Ex. : value is 240, the temperature is 24 Celsius.) + If the temperature measurement is not installed this + value will be 0. + Valid values are 5 to 999 ( 0.5 to 99.9 Celsius). + Set with Zero value to clear the max. temperature." +::= { acsPowerMgmtPDUTableEntry 20 } + +acsPowerMgmtPDUTableTemperature3Value OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS obsolete + DESCRIPTION + "Temperature of this PM unit in Celsius degrees. + The value of this object is the actual temperature in + degrees C * 10. You need to translate the readed value + (Ex. : value is 240, the temperature is 24 Celsius.) + If the temperature measurement is not installed this + value will be 0. + Valid values are 5 to 999 ( 0.5 to 99.9 Celsius)." +::= { acsPowerMgmtPDUTableEntry 21 } + +acsPowerMgmtPDUTableTemperature3Max OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS obsolete + DESCRIPTION + "Maximum temperature detected in this PM unit in Celsius degrees. + The value will be Zero when the PDU does not have support for maximum value. + The value of this object is the actual temperature in + degrees C * 10. You need to translate the readed value + (Ex. : value is 240, the temperature is 24 Celsius.) + If the temperature measurement is not installed this + value will be 0. + Valid values are 5 to 999 ( 0.5 to 99.9 Celsius). + Set with Zero value to clear the max. temperature." +::= { acsPowerMgmtPDUTableEntry 22 } + +acsPowerMgmtPDUTableHumidityNOS OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS obsolete + DESCRIPTION + "Number of humidity sensors in the PDU." +::= { acsPowerMgmtPDUTableEntry 23 } + +acsPowerMgmtPDUTableHumidity1Value OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS obsolete + DESCRIPTION + "Humidity of this PM unit . + If the humidity measurement is not installed this + value will be 0." +::= { acsPowerMgmtPDUTableEntry 24 } + +acsPowerMgmtPDUTableHumidity1Max OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS obsolete + DESCRIPTION + "Maximum humidity detected in this PM unit. + If the humidity measurement is not installed or the PDU does not have support for maximum value this + value will be 0. + Set with Zero value to clear the max. temperature." +::= { acsPowerMgmtPDUTableEntry 25 } + +acsPowerMgmtPDUTableHumidity2Value OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS obsolete + DESCRIPTION + "Humidity of this PM unit . + If the humidity measurement is not installed this + value will be 0." +::= { acsPowerMgmtPDUTableEntry 26 } + +acsPowerMgmtPDUTableHumidity2Max OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS obsolete + DESCRIPTION + "Maximum humidity detected in this PM unit. + If the humidity measurement is not installed or the PDU does not have support for maximum value this + value will be 0. + Set with Zero value to clear the max. temperature." +::= { acsPowerMgmtPDUTableEntry 27 } + +acsPowerMgmtPDUTableHumidity3Value OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS obsolete + DESCRIPTION + "Humidity of this PM unit . + If the humidity measurement is not installed this + value will be 0." +::= { acsPowerMgmtPDUTableEntry 28 } + +acsPowerMgmtPDUTableHumidity3Max OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS obsolete + DESCRIPTION + "Maximum humidity detected in this PM unit. + If the humidity measurement is not installed or the PDU does not have support for maximum value this + value will be 0. + Set with Zero value to clear the max. temperature." +::= { acsPowerMgmtPDUTableEntry 29 } + +acsPowerMgmtPDUTableVoltageNOS OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS obsolete + DESCRIPTION + "Number of voltage sensors in the PDU." +::= { acsPowerMgmtPDUTableEntry 30 } + +acsPowerMgmtPDUTableVoltage1Value OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS obsolete + DESCRIPTION + "Voltage of this sensor in this PDU unit." +::= { acsPowerMgmtPDUTableEntry 31 } + +acsPowerMgmtPDUTableVoltage1Max OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS obsolete + DESCRIPTION + "Maximum voltage of this sensor in this PDU unit. + Set with Zero value to clear the maximum voltage." +::= { acsPowerMgmtPDUTableEntry 32 } + +acsPowerMgmtPDUTableVoltage2Value OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS obsolete + DESCRIPTION + "Voltage of this sensor in this PDU unit." +::= { acsPowerMgmtPDUTableEntry 33 } + +acsPowerMgmtPDUTableVoltage2Max OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS obsolete + DESCRIPTION + "Maximum voltage of this sensor in this PDU unit. + Set with Zero value to clear the maximum voltage." +::= { acsPowerMgmtPDUTableEntry 34 } + +acsPowerMgmtPDUTableVoltage3Value OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS obsolete + DESCRIPTION + "Voltage of this sensor in this PDU unit." +::= { acsPowerMgmtPDUTableEntry 35 } + +acsPowerMgmtPDUTableVoltage3Max OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS obsolete + DESCRIPTION + "Maximum voltage of this sensor in this PDU unit. + Set with Zero value to clear the maximum voltage." +::= { acsPowerMgmtPDUTableEntry 36 } + +acsPowerMgmtPDUTableNumberOfPhases OBJECT-TYPE + SYNTAX INTEGER { + single-phase (0), + three-phase (3) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Number of phases of this PDU unit." +::= { acsPowerMgmtPDUTableEntry 37 } + +acsPowerMgmtPDUTableNumberOfBanks OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Number of banks of this PDU unit." +::= { acsPowerMgmtPDUTableEntry 38 } + +acsPowerMgmtPDUTableCurrentValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Actual value of current sensor in this PDU.( A x 10 )" +::= { acsPowerMgmtPDUTableEntry 39 } + +acsPowerMgmtPDUTableCurrentMax OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Max detected value of current sensor in this PDU.( A x 10 )" +::= { acsPowerMgmtPDUTableEntry 40 } + +acsPowerMgmtPDUTableCurrentMin OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Min detected value of current sensor in this PDU.( A x 10 )" +::= { acsPowerMgmtPDUTableEntry 41 } + +acsPowerMgmtPDUTableCurrentAvg OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Average value for current sensor in this PDU.( A x 10 )" +::= { acsPowerMgmtPDUTableEntry 42 } + +acsPowerMgmtPDUTableCurrentReset OBJECT-TYPE + SYNTAX INTEGER { + no-action (1), + reset (2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Reset max, min and avg values of current." +::= { acsPowerMgmtPDUTableEntry 43 } + +acsPowerMgmtPDUTableVoltageType OBJECT-TYPE + SYNTAX INTEGER { + none-sensor (0), + estimated (1), + read (2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Type of voltage values." +::= { acsPowerMgmtPDUTableEntry 44 } + +acsPowerMgmtPDUTableVoltageValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Actual value of voltage sensor in this PDU unit.( V )" +::= { acsPowerMgmtPDUTableEntry 45 } + +acsPowerMgmtPDUTableVoltageMax OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Max detected value of voltage sensor in this PDU unit.( V )" +::= { acsPowerMgmtPDUTableEntry 46 } + +acsPowerMgmtPDUTableVoltageMin OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Min detected value of voltage sensor in this PDU unit.( V )" +::= { acsPowerMgmtPDUTableEntry 47 } + +acsPowerMgmtPDUTableVoltageAvg OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Average value for voltage sensor in this PDU unit.( V )" +::= { acsPowerMgmtPDUTableEntry 48 } + +acsPowerMgmtPDUTableVoltageReset OBJECT-TYPE + SYNTAX INTEGER { + no-action (1), + reset (2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Reset max, min and avg values of voltage." +::= { acsPowerMgmtPDUTableEntry 49 } + +acsPowerMgmtPDUTablePowerType OBJECT-TYPE + SYNTAX INTEGER { + none-sensor (0), + estimated (1), + read (2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Type of power consumption values.( W x 10 )" +::= { acsPowerMgmtPDUTableEntry 50 } + +acsPowerMgmtPDUTablePowerValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Actual value of power consumption in this PDU unit.( W x 10 )" +::= { acsPowerMgmtPDUTableEntry 51 } + +acsPowerMgmtPDUTablePowerMax OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Max detected value of power consumption in this PDU unit.( W x 10 )" +::= { acsPowerMgmtPDUTableEntry 52 } + +acsPowerMgmtPDUTablePowerMin OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Min detected value of power consumption in this PDU unit.( W x 10 )" +::= { acsPowerMgmtPDUTableEntry 53 } + +acsPowerMgmtPDUTablePowerAvg OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Average value for power consumption in this PDU unit.( W x 10 )" +::= { acsPowerMgmtPDUTableEntry 54 } + +acsPowerMgmtPDUTablePowerReset OBJECT-TYPE + SYNTAX INTEGER { + no-action (1), + reset (2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Reset max, min and avg values of power consumption." +::= { acsPowerMgmtPDUTableEntry 55 } + +acsPowerMgmtPDUTablePowerFactorType OBJECT-TYPE + SYNTAX INTEGER { + none-sensor (0), + estimated (1), + read (2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Type of power factor values." +::= { acsPowerMgmtPDUTableEntry 56 } + +acsPowerMgmtPDUTablePowerFactorValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Actual value of power factor in this PDU unit.( PF x 100 )" +::= { acsPowerMgmtPDUTableEntry 57 } + +acsPowerMgmtPDUTablePowerFactorMax OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Max detected value of power factor in this PDU unit.( PF x 100 )" +::= { acsPowerMgmtPDUTableEntry 58 } + +acsPowerMgmtPDUTablePowerFactorMin OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Min detected value of power factor in this PDU unit.( PF x 100 )" +::= { acsPowerMgmtPDUTableEntry 59 } + +acsPowerMgmtPDUTablePowerFactorAvg OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Average value for power factor in this PDU unit.( PF x 100 )" +::= { acsPowerMgmtPDUTableEntry 60 } + +acsPowerMgmtPDUTablePowerFactorReset OBJECT-TYPE + SYNTAX INTEGER { + no-action (1), + reset (2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Reset max, min and avg values of power factor." +::= { acsPowerMgmtPDUTableEntry 61 } + +acsPowerMgmtPDUTableAlarm OBJECT-TYPE + SYNTAX INTEGER { + normal (1), + blow-fuse (2), + hw-ocp (3), + high-critical (4), + high-warning (5), + low-warning (6), + low-critical (7) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Show the PDU alarm status." +::= { acsPowerMgmtPDUTableEntry 62 } + +acsPowerMgmtPDUTableEnvSensors OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of environmental sensor in this PDU." +::= { acsPowerMgmtPDUTableEntry 63 } + + +acsPowerMgmtTotalNumberOfOutlets OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of outlets managed by the appliance." +::= { acsPowerMgmt 4 } + +acsPowerMgmtOutletsTable OBJECT-TYPE + SYNTAX SEQUENCE OF AcsPowerMgmtOutletsTableEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table contains the information about outlets." +::= { acsPowerMgmt 5 } + +acsPowerMgmtOutletsTableEntry OBJECT-TYPE + SYNTAX AcsPowerMgmtOutletsTableEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "each entry has the information about the outlet." + INDEX { acsPowerMgmtOutletsTablePortNumber, + acsPowerMgmtOutletsTablePduNumber, + acsPowerMgmtOutletsTableNumber } +::= { acsPowerMgmtOutletsTable 1 } + +AcsPowerMgmtOutletsTableEntry ::= SEQUENCE { + acsPowerMgmtOutletsTablePortNumber InterfaceIndex, -- serial port # + acsPowerMgmtOutletsTablePduNumber InterfaceIndex, + acsPowerMgmtOutletsTableNumber InterfaceIndex, -- outlet number in PDU + acsPowerMgmtOutletsTableName DisplayString, -- outlet name + acsPowerMgmtOutletsTableStatus INTEGER, -- outlet status + acsPowerMgmtOutletsTablePowerControl INTEGER, -- manage the outlet + acsPowerMgmtOutletsTablePortName DisplayString, -- serial port name + acsPowerMgmtOutletsTablePduId DisplayString -- PDU ID +} + +acsPowerMgmtOutletsTablePortNumber OBJECT-TYPE + SYNTAX InterfaceIndex + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Serial Port number." +::= { acsPowerMgmtOutletsTableEntry 1 } + +acsPowerMgmtOutletsTablePduNumber OBJECT-TYPE + SYNTAX InterfaceIndex + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Index." +::= { acsPowerMgmtOutletsTableEntry 2 } + +acsPowerMgmtOutletsTableNumber OBJECT-TYPE + SYNTAX InterfaceIndex + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of the outlet in the PDU." +::= { acsPowerMgmtOutletsTableEntry 3 } + +acsPowerMgmtOutletsTableName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Name of the outlet." +::= { acsPowerMgmtOutletsTableEntry 4 } + +acsPowerMgmtOutletsTableStatus OBJECT-TYPE + SYNTAX INTEGER { + off(1), + on(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Status of the outlet." +::= { acsPowerMgmtOutletsTableEntry 5 } + +acsPowerMgmtOutletsTablePowerControl OBJECT-TYPE + SYNTAX INTEGER { + noAction(1), + powerOn(2), + powerOff(3), + powerCycle(4), + powerLock(5), + powerUnlock(6) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "A set value of power*(2-6) will send command to PDU. + noAction(1) = always returned in a GET. Does nothing if SET. + powerOn(2) = when SET the power On command is sent to PDU. + powerOff(3) = when SET the power Off command is sent to PDU. + powerCycle(4)=when SET the power cycle command is sent to PDU. + powerLock(5)= when SET the power lock command is sent to PDU. + powerUnlock(6)=when SET the power unlock command is sent to PDU. + The powerLock and powerUnlock are valid only for Cyclades-PM PDUs" +::= { acsPowerMgmtOutletsTableEntry 6 } + +acsPowerMgmtOutletsTablePortName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Serial Port Name where the PDU is connected." +::= { acsPowerMgmtOutletsTableEntry 7 } + +acsPowerMgmtOutletsTablePduId OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "PDU identification." +::= { acsPowerMgmtOutletsTableEntry 8 } + +acsPowerMgmtNumberOfOutletGroup OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of configured group of outlets." +::= { acsPowerMgmt 6 } + +acsPowerMgmtGroupTable OBJECT-TYPE + SYNTAX SEQUENCE OF AcsPowerMgmtGroupTableEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table contains the information about group of outlets." +::= { acsPowerMgmt 7 } + +acsPowerMgmtGroupTableEntry OBJECT-TYPE + SYNTAX AcsPowerMgmtGroupTableEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "each entry has the information about group of outlets." + INDEX { acsPowerMgmtGroupTableIndex } +::= { acsPowerMgmtGroupTable 1 } + +AcsPowerMgmtGroupTableEntry ::= SEQUENCE { + acsPowerMgmtGroupTableIndex InterfaceIndexOrZero, + acsPowerMgmtGroupTableName DisplayString, -- group name + acsPowerMgmtGroupTableStatus INTEGER, -- group status + acsPowerMgmtGroupTablePowerControl INTEGER -- manage the group +} + +acsPowerMgmtGroupTableIndex OBJECT-TYPE + SYNTAX InterfaceIndexOrZero + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Index of the group." +::= { acsPowerMgmtGroupTableEntry 1 } + +acsPowerMgmtGroupTableName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Name of the group of outlets." +::= { acsPowerMgmtGroupTableEntry 2 } + +acsPowerMgmtGroupTableStatus OBJECT-TYPE + SYNTAX INTEGER { + off(1), + on(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Status of the group of outlet." +::= { acsPowerMgmtGroupTableEntry 3 } + +acsPowerMgmtGroupTablePowerControl OBJECT-TYPE + SYNTAX INTEGER { + noAction(1), + powerOn(2), + powerOff(3), + powerCycle(4) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "A set value of power*(2-6) will send command to PDU. + noAction(1) = always returned in a GET. Does nothing if SET. + powerOn(2) = when SET the power On command is sent to PDU. + powerOff(3) = when SET the power Off command is sent to PDU. + powerCycle(4)=when SET the power cycle command is sent to PDU." +::= { acsPowerMgmtGroupTableEntry 4 } + +acsPowerMgmtPhasesTable OBJECT-TYPE + SYNTAX SEQUENCE OF AcsPowerMgmtPhasesTableEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table contains data monitoring of each detected phase." +::= { acsPowerMgmt 8 } + +acsPowerMgmtPhasesTableEntry OBJECT-TYPE + SYNTAX AcsPowerMgmtPhasesTableEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "each entry has the data monitoring about phases." + INDEX { acsPowerMgmtPhasesTablePortNumber, acsPowerMgmtPhasesTablePduIndex, acsPowerMgmtPhasesTablePhaseIndex } +::= { acsPowerMgmtPhasesTable 1 } + +AcsPowerMgmtPhasesTableEntry ::= SEQUENCE { + acsPowerMgmtPhasesTablePortNumber InterfaceIndex, -- number of serial port + acsPowerMgmtPhasesTablePduIndex InterfaceIndexOrZero, -- number of PDU + acsPowerMgmtPhasesTablePhaseIndex InterfaceIndexOrZero, -- phase index + acsPowerMgmtPhasesTablePhaseName DisplayString, -- Phase Name + acsPowerMgmtPhasesTablePduId DisplayString, -- PDU identification + acsPowerMgmtPhasesTablePortName DisplayString, -- Serial Port Name + acsPowerMgmtPhasesTableCurrentValue Integer32, -- actual value of Phase current sensor + acsPowerMgmtPhasesTableCurrentMax Integer32, -- max detected value of current sensor + acsPowerMgmtPhasesTableCurrentMin Integer32, -- min detected value of current sensor + acsPowerMgmtPhasesTableCurrentAvg Integer32, -- average value for current sensor + acsPowerMgmtPhasesTableCurrentReset INTEGER, -- reset max, min and avg values + acsPowerMgmtPhasesTableVoltageType INTEGER, -- type of phase voltage + acsPowerMgmtPhasesTableVoltageValue Integer32, -- actual value of phase voltage + acsPowerMgmtPhasesTableVoltageMax Integer32, -- max value of voltage sensor + acsPowerMgmtPhasesTableVoltageMin Integer32, -- min value of voltage sensor + acsPowerMgmtPhasesTableVoltageAvg Integer32, -- avg value of voltage sensor + acsPowerMgmtPhasesTableVoltageReset INTEGER, -- reset max, min and avg values + acsPowerMgmtPhasesTablePowerType INTEGER, -- type of phase power consumption + acsPowerMgmtPhasesTablePowerValue Integer32, -- actual value of phase power consumption + acsPowerMgmtPhasesTablePowerMax Integer32, -- max value + acsPowerMgmtPhasesTablePowerMin Integer32, -- min value + acsPowerMgmtPhasesTablePowerAvg Integer32, -- average value + acsPowerMgmtPhasesTablePowerReset INTEGER, -- reset max, min and avg values + acsPowerMgmtPhasesTablePowerFactorType INTEGER, -- type of phase power factor + acsPowerMgmtPhasesTablePowerFactorValue Integer32, -- actual value of phase power factor + acsPowerMgmtPhasesTablePowerFactorMax Integer32, -- max value for power factor + acsPowerMgmtPhasesTablePowerFactorMin Integer32, -- min value for power factor + acsPowerMgmtPhasesTablePowerFactorAvg Integer32, -- avg value for power factor + acsPowerMgmtPhasesTablePowerFactorReset INTEGER, -- reset max, min and avg values + acsPowerMgmtPhasesTableAlarm INTEGER -- phase alarm status +} + +acsPowerMgmtPhasesTablePortNumber OBJECT-TYPE + SYNTAX InterfaceIndex + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of serial port when the PDU is connected." +::= { acsPowerMgmtPhasesTableEntry 1 } + +acsPowerMgmtPhasesTablePduIndex OBJECT-TYPE + SYNTAX InterfaceIndexOrZero + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A PDU position in the chain." +::= { acsPowerMgmtPhasesTableEntry 2 } + +acsPowerMgmtPhasesTablePhaseIndex OBJECT-TYPE + SYNTAX InterfaceIndexOrZero + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "phase index in the PDU." +::= { acsPowerMgmtPhasesTableEntry 3 } + +acsPowerMgmtPhasesTablePhaseName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "phase name in the PDU." +::= { acsPowerMgmtPhasesTableEntry 4 } + +acsPowerMgmtPhasesTablePduId OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "PDU identification." +::= { acsPowerMgmtPhasesTableEntry 5 } + +acsPowerMgmtPhasesTablePortName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Name of serial port when the PDU is connected." +::= { acsPowerMgmtPhasesTableEntry 6 } + +acsPowerMgmtPhasesTableCurrentValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Actual value of current sensor in this phase.( A x 10 )" +::= { acsPowerMgmtPhasesTableEntry 7 } + +acsPowerMgmtPhasesTableCurrentMax OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Max detected value of current sensor in this phase.( A x 10 )" +::= { acsPowerMgmtPhasesTableEntry 8 } + +acsPowerMgmtPhasesTableCurrentMin OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Min detected value of current sensor in this phase.( A x 10 )" +::= { acsPowerMgmtPhasesTableEntry 9 } + +acsPowerMgmtPhasesTableCurrentAvg OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Average value for current sensor in this phase.( A x 10 )" +::= { acsPowerMgmtPhasesTableEntry 10 } + +acsPowerMgmtPhasesTableCurrentReset OBJECT-TYPE + SYNTAX INTEGER { + no-action (1), + reset (2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Reset max, min and avg values of current." +::= { acsPowerMgmtPhasesTableEntry 11 } + +acsPowerMgmtPhasesTableVoltageType OBJECT-TYPE + SYNTAX INTEGER { + none-sensor (0), + estimated (1), + read (2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Type of voltage values." +::= { acsPowerMgmtPhasesTableEntry 12 } + +acsPowerMgmtPhasesTableVoltageValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Actual value of voltage sensor in this phase.( V )" +::= { acsPowerMgmtPhasesTableEntry 13 } + +acsPowerMgmtPhasesTableVoltageMax OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Max detected value of voltage sensor in this phase.( V )" +::= { acsPowerMgmtPhasesTableEntry 14 } + +acsPowerMgmtPhasesTableVoltageMin OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Min detected value of voltage sensor in this phase.( V )" +::= { acsPowerMgmtPhasesTableEntry 15 } + +acsPowerMgmtPhasesTableVoltageAvg OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Average value for voltage sensor in this phase.( V )" +::= { acsPowerMgmtPhasesTableEntry 16 } + +acsPowerMgmtPhasesTableVoltageReset OBJECT-TYPE + SYNTAX INTEGER { + no-action (1), + reset (2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Reset max, min and avg values of voltage." +::= { acsPowerMgmtPhasesTableEntry 17 } + +acsPowerMgmtPhasesTablePowerType OBJECT-TYPE + SYNTAX INTEGER { + none-sensor (0), + estimated (1), + read (2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Type of power consumption values." +::= { acsPowerMgmtPhasesTableEntry 18 } + +acsPowerMgmtPhasesTablePowerValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Actual value of power consumption in this phase.( W x 10 )" +::= { acsPowerMgmtPhasesTableEntry 19 } + +acsPowerMgmtPhasesTablePowerMax OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Max detected value of power consumption in this phase.( W x 10 )" +::= { acsPowerMgmtPhasesTableEntry 20 } + +acsPowerMgmtPhasesTablePowerMin OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Min detected value of power consumption in this phase.( W x 10 )" +::= { acsPowerMgmtPhasesTableEntry 21 } + +acsPowerMgmtPhasesTablePowerAvg OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Average value for power consumption in this phase.( W x 10 )" +::= { acsPowerMgmtPhasesTableEntry 22 } + +acsPowerMgmtPhasesTablePowerReset OBJECT-TYPE + SYNTAX INTEGER { + no-action (1), + reset (2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Reset max, min and avg values of power consumption." +::= { acsPowerMgmtPhasesTableEntry 23 } + +acsPowerMgmtPhasesTablePowerFactorType OBJECT-TYPE + SYNTAX INTEGER { + none-sensor (0), + estimated (1), + read (2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Type of power factor values." +::= { acsPowerMgmtPhasesTableEntry 24 } + +acsPowerMgmtPhasesTablePowerFactorValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Actual value of power factor in this phase.( PF x 100 )" +::= { acsPowerMgmtPhasesTableEntry 25 } + +acsPowerMgmtPhasesTablePowerFactorMax OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Max detected value of power factor in this phase.( PF x 100 )" +::= { acsPowerMgmtPhasesTableEntry 26 } + +acsPowerMgmtPhasesTablePowerFactorMin OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Min detected value of power factor in this phase.( PF x 100 )" +::= { acsPowerMgmtPhasesTableEntry 27 } + +acsPowerMgmtPhasesTablePowerFactorAvg OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Average value for power factor in this phase.( PF x 100 )" +::= { acsPowerMgmtPhasesTableEntry 28 } + +acsPowerMgmtPhasesTablePowerFactorReset OBJECT-TYPE + SYNTAX INTEGER { + no-action (1), + reset (2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Reset max, min and avg values of power factor." +::= { acsPowerMgmtPhasesTableEntry 29 } + +acsPowerMgmtPhasesTableAlarm OBJECT-TYPE + SYNTAX INTEGER { + normal (1), + blow-fuse (2), + hw-ocp (3), + high-critical (4), + high-warning (5), + low-warning (6), + low-critical (7) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Show the phase alarm status." +::= { acsPowerMgmtPhasesTableEntry 30 } + +acsPowerMgmtBanksTable OBJECT-TYPE + SYNTAX SEQUENCE OF AcsPowerMgmtBanksTableEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table contains data monitoring of each detected bank." +::= { acsPowerMgmt 9 } + +acsPowerMgmtBanksTableEntry OBJECT-TYPE + SYNTAX AcsPowerMgmtBanksTableEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "each entry has the data monitoring about bank." + INDEX { acsPowerMgmtBanksTablePortNumber, acsPowerMgmtBanksTablePduIndex, acsPowerMgmtBanksTableBankIndex } +::= { acsPowerMgmtBanksTable 1 } + +AcsPowerMgmtBanksTableEntry ::= SEQUENCE { + acsPowerMgmtBanksTablePortNumber InterfaceIndex, -- number of serial port + acsPowerMgmtBanksTablePduIndex InterfaceIndexOrZero, -- number of PDU + acsPowerMgmtBanksTableBankIndex InterfaceIndexOrZero, -- bank index + acsPowerMgmtBanksTableBankName DisplayString, -- Bank Name + acsPowerMgmtBanksTablePduId DisplayString, -- PDU identification + acsPowerMgmtBanksTablePortName DisplayString, -- Serial Port Name + acsPowerMgmtBanksTableCurrentValue Integer32, -- actual value of bank current sensor + acsPowerMgmtBanksTableCurrentMax Integer32, -- max detected value of current sensor + acsPowerMgmtBanksTableCurrentMin Integer32, -- min detected value of current sensor + acsPowerMgmtBanksTableCurrentAvg Integer32, -- average value for current sensor + acsPowerMgmtBanksTableCurrentReset INTEGER, -- reset max, min and avg values + acsPowerMgmtBanksTableVoltageType INTEGER, -- type of bank voltage + acsPowerMgmtBanksTableVoltageValue Integer32, -- actual value of bank voltage + acsPowerMgmtBanksTableVoltageMax Integer32, -- max value of voltage sensor + acsPowerMgmtBanksTableVoltageMin Integer32, -- min value of voltage sensor + acsPowerMgmtBanksTableVoltageAvg Integer32, -- avg value of voltage sensor + acsPowerMgmtBanksTableVoltageReset INTEGER, -- reset max, min and avg values + acsPowerMgmtBanksTablePowerType INTEGER, -- type of bank power consumption + acsPowerMgmtBanksTablePowerValue Integer32, -- actual value of bank power consumption + acsPowerMgmtBanksTablePowerMax Integer32, -- max value + acsPowerMgmtBanksTablePowerMin Integer32, -- min value + acsPowerMgmtBanksTablePowerAvg Integer32, -- average value + acsPowerMgmtBanksTablePowerReset INTEGER, -- reset max, min and avg values + acsPowerMgmtBanksTablePowerFactorType INTEGER, -- type of bank power factor + acsPowerMgmtBanksTablePowerFactorValue Integer32, -- actual value of bank power factor + acsPowerMgmtBanksTablePowerFactorMax Integer32, -- max value for power factor + acsPowerMgmtBanksTablePowerFactorMin Integer32, -- min value for power factor + acsPowerMgmtBanksTablePowerFactorAvg Integer32, -- avg value for power factor + acsPowerMgmtBanksTablePowerFactorReset INTEGER, -- reset max, min and avg values + acsPowerMgmtBanksTableAlarm INTEGER -- status of bank alarm +} + +acsPowerMgmtBanksTablePortNumber OBJECT-TYPE + SYNTAX InterfaceIndex + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of serial port when the PDU is connected." +::= { acsPowerMgmtBanksTableEntry 1 } + +acsPowerMgmtBanksTablePduIndex OBJECT-TYPE + SYNTAX InterfaceIndexOrZero + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A PDU position in the chain." +::= { acsPowerMgmtBanksTableEntry 2 } + +acsPowerMgmtBanksTableBankIndex OBJECT-TYPE + SYNTAX InterfaceIndexOrZero + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Bank index in the PDU." +::= { acsPowerMgmtBanksTableEntry 3 } + +acsPowerMgmtBanksTableBankName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Bank name in the PDU." +::= { acsPowerMgmtBanksTableEntry 4 } + +acsPowerMgmtBanksTablePduId OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "PDU identification." +::= { acsPowerMgmtBanksTableEntry 5 } + +acsPowerMgmtBanksTablePortName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Name of serial port when the PDU is connected." +::= { acsPowerMgmtBanksTableEntry 6 } + +acsPowerMgmtBanksTableCurrentValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Actual value of current sensor in this bank.( A x 10 )" +::= { acsPowerMgmtBanksTableEntry 7 } + +acsPowerMgmtBanksTableCurrentMax OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Max detected value of current sensor in this bank.( A x 10 )" +::= { acsPowerMgmtBanksTableEntry 8 } + +acsPowerMgmtBanksTableCurrentMin OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Min detected value of current sensor in this bank.( A x 10 )" +::= { acsPowerMgmtBanksTableEntry 9 } + +acsPowerMgmtBanksTableCurrentAvg OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Average value for current sensor in this bank.( A x 10 )" +::= { acsPowerMgmtBanksTableEntry 10 } + +acsPowerMgmtBanksTableCurrentReset OBJECT-TYPE + SYNTAX INTEGER { + no-action (1), + reset (2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Reset max, min and avg values of current." +::= { acsPowerMgmtBanksTableEntry 11 } + +acsPowerMgmtBanksTableVoltageType OBJECT-TYPE + SYNTAX INTEGER { + none-sensor (0), + estimated (1), + read (2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Type of voltage values." +::= { acsPowerMgmtBanksTableEntry 12 } + +acsPowerMgmtBanksTableVoltageValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Actual value of voltage sensor in this bank.( V )" +::= { acsPowerMgmtBanksTableEntry 13 } + +acsPowerMgmtBanksTableVoltageMax OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Max detected value of voltage sensor in this bank.( V )" +::= { acsPowerMgmtBanksTableEntry 14 } + +acsPowerMgmtBanksTableVoltageMin OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Min detected value of voltage sensor in this bank.( V )" +::= { acsPowerMgmtBanksTableEntry 15 } + +acsPowerMgmtBanksTableVoltageAvg OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Average value for voltage sensor in this bank.( V )" +::= { acsPowerMgmtBanksTableEntry 16 } + +acsPowerMgmtBanksTableVoltageReset OBJECT-TYPE + SYNTAX INTEGER { + no-action (1), + reset (2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Reset max, min and avg values of voltage." +::= { acsPowerMgmtBanksTableEntry 17 } + +acsPowerMgmtBanksTablePowerType OBJECT-TYPE + SYNTAX INTEGER { + none-sensor (0), + estimated (1), + read (2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Type of power consumption values." +::= { acsPowerMgmtBanksTableEntry 18 } + +acsPowerMgmtBanksTablePowerValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Actual value of power consumption in this bank.( W x 10 )" +::= { acsPowerMgmtBanksTableEntry 19 } + +acsPowerMgmtBanksTablePowerMax OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Max detected value of power consumption in this bank.( W x 10 )" +::= { acsPowerMgmtBanksTableEntry 20 } + +acsPowerMgmtBanksTablePowerMin OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Min detected value of power consumption in this bank.( W x 10 )" +::= { acsPowerMgmtBanksTableEntry 21 } + +acsPowerMgmtBanksTablePowerAvg OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Average value for power consumption in this bank.( W x 10 )" +::= { acsPowerMgmtBanksTableEntry 22 } + +acsPowerMgmtBanksTablePowerReset OBJECT-TYPE + SYNTAX INTEGER { + no-action (1), + reset (2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Reset max, min and avg values of power consumption." +::= { acsPowerMgmtBanksTableEntry 23 } + +acsPowerMgmtBanksTablePowerFactorType OBJECT-TYPE + SYNTAX INTEGER { + none-sensor (0), + estimated (1), + read (2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Type of power factor values." +::= { acsPowerMgmtBanksTableEntry 24 } + +acsPowerMgmtBanksTablePowerFactorValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Actual value of power factor in this bank.( PF x 100 )" +::= { acsPowerMgmtBanksTableEntry 25 } + +acsPowerMgmtBanksTablePowerFactorMax OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Max detected value of power factor in this bank.( PF x 100 )" +::= { acsPowerMgmtBanksTableEntry 26 } + +acsPowerMgmtBanksTablePowerFactorMin OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Min detected value of power factor in this bank.( PF x 100 )" +::= { acsPowerMgmtBanksTableEntry 27 } + +acsPowerMgmtBanksTablePowerFactorAvg OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Average value for power factor in this bank.( PF x 100 )" +::= { acsPowerMgmtBanksTableEntry 28 } + +acsPowerMgmtBanksTablePowerFactorReset OBJECT-TYPE + SYNTAX INTEGER { + no-action (1), + reset (2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Reset max, min and avg values of power factor." +::= { acsPowerMgmtBanksTableEntry 29 } + +acsPowerMgmtBanksTableAlarm OBJECT-TYPE + SYNTAX INTEGER { + normal (1), + blow-fuse (2), + hw-ocp (3), + high-critical (4), + high-warning (5), + low-warning (6), + low-critical (7) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Show the bank alarm status." +::= { acsPowerMgmtBanksTableEntry 30 } + +acsPowerMgmtEnvMonTable OBJECT-TYPE + SYNTAX SEQUENCE OF AcsPowerMgmtEnvMonTableEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table contains data monitoring of each detected environmental sensor." +::= { acsPowerMgmt 10 } + +acsPowerMgmtEnvMonTableEntry OBJECT-TYPE + SYNTAX AcsPowerMgmtEnvMonTableEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "each entry has the data monitoring about environmental sensors." + INDEX { acsPowerMgmtEnvMonTablePortNumber, acsPowerMgmtEnvMonTablePduIndex, acsPowerMgmtEnvMonTableIndex } +::= { acsPowerMgmtEnvMonTable 1 } + +AcsPowerMgmtEnvMonTableEntry ::= SEQUENCE { + acsPowerMgmtEnvMonTablePortNumber InterfaceIndex, -- number of serial port + acsPowerMgmtEnvMonTablePduIndex InterfaceIndexOrZero, -- number of PDU + acsPowerMgmtEnvMonTableIndex InterfaceIndexOrZero, -- index + acsPowerMgmtEnvMonTableName DisplayString, -- sensor name + acsPowerMgmtEnvMonTablePduId DisplayString, -- PDU identification + acsPowerMgmtEnvMonTablePortName DisplayString, -- Serial Port Name + acsPowerMgmtEnvMonTableType INTEGER, -- environmental sensor type + acsPowerMgmtEnvMonTableStatus INTEGER, -- state of digital sensor + acsPowerMgmtEnvMonTableValue Integer32, -- value + acsPowerMgmtEnvMonTableMaxValue Integer32 -- max value +} + +acsPowerMgmtEnvMonTablePortNumber OBJECT-TYPE + SYNTAX InterfaceIndex + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of serial port when the PDU is connected." +::= { acsPowerMgmtEnvMonTableEntry 1 } + +acsPowerMgmtEnvMonTablePduIndex OBJECT-TYPE + SYNTAX InterfaceIndexOrZero + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A PDU position in the chain." +::= { acsPowerMgmtEnvMonTableEntry 2 } + +acsPowerMgmtEnvMonTableIndex OBJECT-TYPE + SYNTAX InterfaceIndexOrZero + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "envmon sensor index." +::= { acsPowerMgmtEnvMonTableEntry 3 } + +acsPowerMgmtEnvMonTableName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "envmon sensor name." +::= { acsPowerMgmtEnvMonTableEntry 4 } + +acsPowerMgmtEnvMonTablePduId OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "PDU identification." +::= { acsPowerMgmtEnvMonTableEntry 5 } + +acsPowerMgmtEnvMonTablePortName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Name of serial port when the PDU is connected." +::= { acsPowerMgmtEnvMonTableEntry 6 } + +acsPowerMgmtEnvMonTableType OBJECT-TYPE + SYNTAX INTEGER { + temp-internal (1), + temperature (2), + humidity (3), + air-flow (4), + smoke (5), + dry-concact (6), + water-level (7), + motion (8), + unplugged (9), + unknown (10) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The type of environmental monitor." +::= { acsPowerMgmtEnvMonTableEntry 7 } + +acsPowerMgmtEnvMonTableStatus OBJECT-TYPE + SYNTAX INTEGER { + normal(1), + triggered(2), + not-applicable(3) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Status of digital sensors: + Dry-Contact, Water level, Smoke sensor, Motion sensor." +::= { acsPowerMgmtEnvMonTableEntry 8 } + +acsPowerMgmtEnvMonTableValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Detected value for envmon sensors. Temperature: C x 10. Humidity: %. Air flow: afu." +::= { acsPowerMgmtEnvMonTableEntry 9 } + +acsPowerMgmtEnvMonTableMaxValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Max detected value for envmon sensors. Temperature: C x 10. Humidity: %. Air flow: afu." +::= { acsPowerMgmtEnvMonTableEntry 10 } + +acsPowerMgmtOutElecMonTable OBJECT-TYPE + SYNTAX SEQUENCE OF AcsPowerMgmtOutElecMonTableEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table contains the information about data monitoring of outlets." +::= { acsPowerMgmt 11 } + +acsPowerMgmtOutElecMonTableEntry OBJECT-TYPE + SYNTAX AcsPowerMgmtOutElecMonTableEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "each entry has the information about the outlet." + INDEX { acsPowerMgmtOutElecMonTablePortNumber, + acsPowerMgmtOutElecMonTablePduNumber, + acsPowerMgmtOutElecMonTableNumber } +::= { acsPowerMgmtOutElecMonTable 1 } + +AcsPowerMgmtOutElecMonTableEntry ::= SEQUENCE { + acsPowerMgmtOutElecMonTablePortNumber InterfaceIndex, -- serial port # + acsPowerMgmtOutElecMonTablePduNumber InterfaceIndex, + acsPowerMgmtOutElecMonTableNumber InterfaceIndex, -- outlet number in PDU + acsPowerMgmtOutElecMonTableCurrentValue Integer32, -- actual value for current + acsPowerMgmtOutElecMonTableCurrentMax Integer32, -- max detected value for current + acsPowerMgmtOutElecMonTableCurrentMin Integer32, -- min detected value for current + acsPowerMgmtOutElecMonTableCurrentAvg Integer32, -- average value for current + acsPowerMgmtOutElecMonTableCurrentReset INTEGER, -- reset max, min and avg values of current + acsPowerMgmtOutElecMonTablePowerValue Integer32, -- actual value for power + acsPowerMgmtOutElecMonTablePowerMax Integer32, -- max detected value for power + acsPowerMgmtOutElecMonTablePowerMin Integer32, -- min detected value for power + acsPowerMgmtOutElecMonTablePowerAvg Integer32, -- average value for power + acsPowerMgmtOutElecMonTablePowerReset INTEGER, -- reset max, min and avg values of power + acsPowerMgmtOutElecMonTableVoltageValue Integer32, -- actual value for voltage + acsPowerMgmtOutElecMonTableVoltageMax Integer32, -- max detected value for voltage + acsPowerMgmtOutElecMonTableVoltageMin Integer32, -- min detected value for voltage + acsPowerMgmtOutElecMonTableVoltageAvg Integer32, -- average value for voltage + acsPowerMgmtOutElecMonTableVoltageReset INTEGER, -- reset max, min and avg values of voltage + acsPowerMgmtOutElecMonTablePowerFactorValue Integer32, -- actual value for power factor + acsPowerMgmtOutElecMonTablePowerFactorMax Integer32, -- max detected value for power factor + acsPowerMgmtOutElecMonTablePowerFactorMin Integer32, -- min detected value for power factor + acsPowerMgmtOutElecMonTablePowerFactorAvg Integer32, -- avg value for power factor + acsPowerMgmtOutElecMonTablePowerFactorReset INTEGER, -- reset max, min and avg values of power factor + acsPowerMgmtOutElecMonTableAlarm INTEGER -- outlet alarm status +} + +acsPowerMgmtOutElecMonTablePortNumber OBJECT-TYPE + SYNTAX InterfaceIndex + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Serial Port number." +::= { acsPowerMgmtOutElecMonTableEntry 1 } + +acsPowerMgmtOutElecMonTablePduNumber OBJECT-TYPE + SYNTAX InterfaceIndex + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Index." +::= { acsPowerMgmtOutElecMonTableEntry 2 } + +acsPowerMgmtOutElecMonTableNumber OBJECT-TYPE + SYNTAX InterfaceIndex + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of the outlet in the PDU." +::= { acsPowerMgmtOutElecMonTableEntry 3 } + +acsPowerMgmtOutElecMonTableCurrentValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Actual value of outlet current sensor.( A x 10 )" +::= { acsPowerMgmtOutElecMonTableEntry 4 } + +acsPowerMgmtOutElecMonTableCurrentMax OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Max detected value of outlet current sensor.( A x 10 )" +::= { acsPowerMgmtOutElecMonTableEntry 5 } + +acsPowerMgmtOutElecMonTableCurrentMin OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Min detected value of outlet current sensor.( A x 10 )" +::= { acsPowerMgmtOutElecMonTableEntry 6 } + +acsPowerMgmtOutElecMonTableCurrentAvg OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Average value for outlet current sensor.( A x 10 )" +::= { acsPowerMgmtOutElecMonTableEntry 7 } + +acsPowerMgmtOutElecMonTableCurrentReset OBJECT-TYPE + SYNTAX INTEGER { + noAction(1), + reset(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Reset max, min and avertage values of outlet current." +::= { acsPowerMgmtOutElecMonTableEntry 8 } + +acsPowerMgmtOutElecMonTablePowerValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Actual value of outlet power comsumption sensor.( W x 10 )" +::= { acsPowerMgmtOutElecMonTableEntry 9 } + +acsPowerMgmtOutElecMonTablePowerMax OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Max detected value of outlet power comsumption sensor.( W x 10 )" +::= { acsPowerMgmtOutElecMonTableEntry 10 } + +acsPowerMgmtOutElecMonTablePowerMin OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Min detected value of outlet power comsumption sensor.( W x 10 )" +::= { acsPowerMgmtOutElecMonTableEntry 11 } + +acsPowerMgmtOutElecMonTablePowerAvg OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Average value for outlet power comsumption sensor.( W x 10 )" +::= { acsPowerMgmtOutElecMonTableEntry 12 } + +acsPowerMgmtOutElecMonTablePowerReset OBJECT-TYPE + SYNTAX INTEGER { + noAction(1), + reset(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Reset max, min and avertage values of outlet power comsumption." +::= { acsPowerMgmtOutElecMonTableEntry 13 } + +acsPowerMgmtOutElecMonTableVoltageValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Actual value of outlet voltage sensor.( V )" +::= { acsPowerMgmtOutElecMonTableEntry 14 } + +acsPowerMgmtOutElecMonTableVoltageMax OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Max detected value of outlet voltage sensor.( V )" +::= { acsPowerMgmtOutElecMonTableEntry 15 } + +acsPowerMgmtOutElecMonTableVoltageMin OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Min detected value of outlet voltage sensor.( V )" +::= { acsPowerMgmtOutElecMonTableEntry 16 } + +acsPowerMgmtOutElecMonTableVoltageAvg OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Average value for outlet voltage sensor.( V )" +::= { acsPowerMgmtOutElecMonTableEntry 17 } + +acsPowerMgmtOutElecMonTableVoltageReset OBJECT-TYPE + SYNTAX INTEGER { + noAction(1), + reset(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Reset max, min and avertage values of outlet voltage." +::= { acsPowerMgmtOutElecMonTableEntry 18 } + +acsPowerMgmtOutElecMonTablePowerFactorValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Actual value of outlet power-factor sensor.( PF x 100 )" +::= { acsPowerMgmtOutElecMonTableEntry 19 } + +acsPowerMgmtOutElecMonTablePowerFactorMax OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Max detected value of outlet power-factor sensor.( PF x 100 )" +::= { acsPowerMgmtOutElecMonTableEntry 20 } + +acsPowerMgmtOutElecMonTablePowerFactorMin OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Min detected value of outlet power-factor sensor.( PF x 100 )" +::= { acsPowerMgmtOutElecMonTableEntry 21 } + +acsPowerMgmtOutElecMonTablePowerFactorAvg OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Average value for outlet power-factor sensor.( PF x 100 )" +::= { acsPowerMgmtOutElecMonTableEntry 22 } + +acsPowerMgmtOutElecMonTablePowerFactorReset OBJECT-TYPE + SYNTAX INTEGER { + noAction(1), + reset(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Reset max, min and avertage values of outlet power-factor." +::= { acsPowerMgmtOutElecMonTableEntry 23 } + +acsPowerMgmtOutElecMonTableAlarm OBJECT-TYPE + SYNTAX INTEGER { + normal (1), + blow-fuse (2), + hw-ocp (3), + high-critical (4), + high-warning (5), + low-warning (6), + low-critical (7) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Show the outlet alarm status." +::= { acsPowerMgmtOutElecMonTableEntry 24 } + +END |