summaryrefslogtreecommitdiff
path: root/MIBS/axis
diff options
context:
space:
mode:
authorDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
committerDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
commit98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch)
tree9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/axis
downloadmibs-main.tar.gz
mibs-main.zip
Initial commitHEADmain
Diffstat (limited to 'MIBS/axis')
-rwxr-xr-xMIBS/axis/AXIS-ROOT-MIB36
-rwxr-xr-xMIBS/axis/AXIS-VIDEO-MIB576
2 files changed, 612 insertions, 0 deletions
diff --git a/MIBS/axis/AXIS-ROOT-MIB b/MIBS/axis/AXIS-ROOT-MIB
new file mode 100755
index 0000000..b558413
--- /dev/null
+++ b/MIBS/axis/AXIS-ROOT-MIB
@@ -0,0 +1,36 @@
+AXIS-ROOT-MIB DEFINITIONS ::= BEGIN
+
+IMPORTS
+ enterprises, MODULE-IDENTITY, OBJECT-IDENTITY
+ FROM SNMPv2-SMI;
+
+axis MODULE-IDENTITY
+ LAST-UPDATED "201206081000Z"
+ ORGANIZATION "Axis Communications AB"
+ CONTACT-INFO
+ "Postal: Axis Communications AB
+ Emdalavagen 14
+ SE-223 69 Lund
+ Sweden
+ Phone: +46 (0)46 272 18 00
+ Fax: +46 (0)46 13 61 30
+ E-Mail: info@axis.com
+ Web: www.axis.com"
+ DESCRIPTION
+ "The AXIS root MIB."
+ REVISION "201206081000Z"
+ DESCRIPTION
+ "Initial version of this MIB module."
+ ::= { enterprises 368 } -- assigned by IANA
+
+products OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "products is the root OBJECT IDENTIFIER from which
+ sysObjectID values are assigned. Actual values and
+ respectively products sub-tree are defined in:
+ AXIS-PRINTSERVER-MIB
+ AXIS-VIDEO-MIB"
+ ::= { axis 1 }
+
+END
diff --git a/MIBS/axis/AXIS-VIDEO-MIB b/MIBS/axis/AXIS-VIDEO-MIB
new file mode 100755
index 0000000..0111f9b
--- /dev/null
+++ b/MIBS/axis/AXIS-VIDEO-MIB
@@ -0,0 +1,576 @@
+AXIS-VIDEO-MIB DEFINITIONS ::= BEGIN
+
+IMPORTS
+ axis, products
+ FROM AXIS-ROOT-MIB
+ MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
+ FROM SNMPv2-CONF -- RFC 2580
+ Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-TYPE,
+ Unsigned32
+ FROM SNMPv2-SMI -- RFC 2578
+ SnmpAdminString
+ FROM SNMP-FRAMEWORK-MIB; -- RFC 3411
+
+video MODULE-IDENTITY
+ LAST-UPDATED "201609231218Z"
+ ORGANIZATION
+ "Axis Communications AB"
+ CONTACT-INFO
+ "Postal: Axis Communications AB
+ Emdalavagen 14
+ SE-223 69 Lund
+ Sweden
+ Phone: +46 (0)46 272 18 00
+ Fax: +46 (0)46 13 61 30
+ E-Mail: info@axis.com
+ Web: www.axis.com"
+ DESCRIPTION
+ "Axis Video MIB. Includes HW resources, such as power
+ supplies, and traps for notifying management stations when
+ something fails."
+ REVISION "201609231218Z"
+ DESCRIPTION
+ "Updates in the compliance statement. Video products do not support all
+ objects in general."
+ REVISION "201212121202Z"
+ DESCRIPTION
+ "Initial version."
+ ::= { axis 4 }
+
+-- Object identifiers: all video products return the videoBased OID
+--- Note: video cannot be used, since it is used above.
+videoBased OBJECT IDENTIFIER
+ ::= { products 1 }
+
+videoObjects OBJECT IDENTIFIER
+ ::= { video 1 }
+
+-- Power supplies
+powerSupplyTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PowerSupplyEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table containing information about all the power supplies
+ present in the device."
+ ::= { videoObjects 1 }
+
+powerSupplyEntry OBJECT-TYPE
+ SYNTAX PowerSupplyEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A power supply entry containing information about
+ a specific power supply."
+ INDEX { powerSupplyType, powerSupplyId }
+ ::= { powerSupplyTable 1 }
+
+PowerSupplyEntry ::= SEQUENCE {
+ powerSupplyType INTEGER,
+ powerSupplyId Unsigned32,
+ powerSupplyStatus INTEGER
+}
+
+powerSupplyType OBJECT-TYPE
+ SYNTAX INTEGER { common(1), internal(2), external(3) }
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Indicates whether the power supply is mounted externally,
+ e.g. in a rack, or internally."
+ ::= { powerSupplyEntry 1 }
+
+powerSupplyId OBJECT-TYPE
+ SYNTAX Unsigned32 (1..128)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Used to identify a power supply. The powerSupplyId is unique
+ within the type, i.e. there can not be two external power
+ supplies with the same powerSupplyId. There can, however, be one
+ external and one internal that have the same powerSupplyId."
+ ::= { powerSupplyEntry 2 }
+
+powerSupplyStatus OBJECT-TYPE
+ SYNTAX INTEGER { ok(1), failure(2) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The status of a power supply."
+ ::= { powerSupplyEntry 3 }
+
+--- Fans
+fanTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF FanEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table containing information about all the fans in the product."
+ ::= { videoObjects 2 }
+
+fanEntry OBJECT-TYPE
+ SYNTAX FanEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A fan entry contains information about a specific fan."
+ INDEX { fanType, fanId }
+ ::= { fanTable 1 }
+
+FanEntry ::= SEQUENCE {
+ fanType INTEGER,
+ fanId Unsigned32,
+ fanStatus INTEGER
+}
+
+fanType OBJECT-TYPE
+ SYNTAX INTEGER { common(1), housing(2), rack(3), cpu(4) }
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The type of the fan, i.e. where the fan is mounted."
+ ::= { fanEntry 1 }
+
+fanId OBJECT-TYPE
+ SYNTAX Unsigned32 (1..128)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Used, together with fanType, to identify a fan. The fanId is
+ unique within the type, i.e. there can not be two fans with the
+ same fanType and the same fanId."
+ ::= { fanEntry 2 }
+
+fanStatus OBJECT-TYPE
+ SYNTAX INTEGER { ok(1), failure(2) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The status of a fan."
+ ::= { fanEntry 3 }
+
+--- Temperature Sensors
+tempSensorTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TempSensorEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table containing information about all the temperature
+ sensors in the product."
+ ::= { videoObjects 3 }
+
+tempSensorEntry OBJECT-TYPE
+ SYNTAX TempSensorEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A temperature sensor entry contains information about a
+ specific temperature sensor."
+ INDEX { tempSensorType, tempSensorId }
+ ::= { tempSensorTable 1 }
+
+TempSensorEntry ::= SEQUENCE {
+ tempSensorType INTEGER,
+ tempSensorId Unsigned32,
+ tempSensorStatus INTEGER,
+ tempSensorValue Integer32
+}
+
+tempSensorType OBJECT-TYPE
+ SYNTAX INTEGER { common(1), housing(2), rack(3), cpu(4) }
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The type of the temperature sensor, i.e. where it is mounted."
+ ::= { tempSensorEntry 1 }
+
+tempSensorId OBJECT-TYPE
+ SYNTAX Unsigned32 (1..128)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Used, together with tempSensorType, to identify a temperature
+ sensor. The tempSensorId is unique within the type, i.e. there
+ can not be two sensors with the same tempSensorType and the same
+ tempSensorId."
+ ::= { tempSensorEntry 2 }
+
+tempSensorStatus OBJECT-TYPE
+ SYNTAX INTEGER { ok(1), failure(2), outOfBoundary(3) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The status of the temperature sensor."
+ ::= { tempSensorEntry 3 }
+
+tempSensorValue OBJECT-TYPE
+ SYNTAX Integer32 (-176..150)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The temperature measured by a specific temperature sensor.
+ The temperature is given in degrees Celsius."
+ ::= { tempSensorEntry 4 }
+
+--- Physical video channels
+videoChannelTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF VideoChannelEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of video channel information, one entry for each
+ physical video channel."
+ ::= { videoObjects 4 }
+
+videoChannelEntry OBJECT-TYPE
+ SYNTAX VideoChannelEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A video channel entry contains information about a specific
+ physical video channel."
+ INDEX { videoChannelId }
+ ::= { videoChannelTable 1 }
+
+VideoChannelEntry ::= SEQUENCE {
+ videoChannelId Unsigned32,
+ videoSignalStatus INTEGER
+}
+
+videoChannelId OBJECT-TYPE
+ SYNTAX Unsigned32 (1..8192)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Used to identify a physical video channel."
+ ::= { videoChannelEntry 1 }
+
+videoSignalStatus OBJECT-TYPE
+ SYNTAX INTEGER { signalOk(1), noSignal(2) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The status of the video signal for a channel."
+ ::= { videoChannelEntry 2 }
+
+--- Physical audio channels
+audioChannelTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AudioChannelEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of audio signal information, one entry for each
+ physical audio channel."
+ ::= { videoObjects 5 }
+
+audioChannelEntry OBJECT-TYPE
+ SYNTAX AudioChannelEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An audio signal entry contains information about a specific
+ physical audio signal."
+ INDEX { audioChannelId }
+ ::= { audioChannelTable 1 }
+
+AudioChannelEntry ::= SEQUENCE {
+ audioChannelId Unsigned32,
+ audioSignalStatus INTEGER
+}
+
+audioChannelId OBJECT-TYPE
+ SYNTAX Unsigned32 (1..8192)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Used to identify a physical audio channel."
+ ::= { audioChannelEntry 1 }
+
+audioSignalStatus OBJECT-TYPE
+ SYNTAX INTEGER { signalOk(1), noSignal(2) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The status of the audio signal for a channel."
+ ::= { audioChannelEntry 2 }
+
+--- Open Casing Detector
+casingTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CasingEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of casing status, one entry for each casing."
+ ::= { videoObjects 6 }
+
+casingEntry OBJECT-TYPE
+ SYNTAX CasingEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A casing entry contains information about a specific casing."
+ INDEX { casingId }
+ ::= { casingTable 1 }
+
+CasingEntry ::= SEQUENCE {
+ casingId Unsigned32,
+ casingName SnmpAdminString,
+ casingStatus INTEGER
+}
+
+casingId OBJECT-TYPE
+ SYNTAX Unsigned32 (1..32)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Used to identify a casing."
+ ::= { casingEntry 1 }
+
+casingName OBJECT-TYPE
+ SYNTAX SnmpAdminString (SIZE(0..32))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Used to identify a casing. If the original string is longer than the
+ specified length then the middle of the string will be replaced by '..'
+ in such a way that the length of the string becomes 32 characters
+ anyway."
+ ::= { casingEntry 2 }
+
+casingStatus OBJECT-TYPE
+ SYNTAX INTEGER { closed(1), open(2) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The status of the casing."
+ ::= { casingEntry 3 }
+
+--- { videoObjects 7 }, reserved for PTZ
+
+--- Storage
+storageTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF StorageEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of storage media properties, one entry for each storage media."
+ ::= { videoObjects 8 }
+
+storageEntry OBJECT-TYPE
+ SYNTAX StorageEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A storage media contains information about a specific medium."
+ INDEX { storageId }
+ ::= { storageTable 1 }
+
+StorageEntry ::= SEQUENCE {
+ storageId Unsigned32,
+ storageName SnmpAdminString,
+ storageDisruptionDetected INTEGER
+}
+
+storageId OBJECT-TYPE
+ SYNTAX Unsigned32 (1..128)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Used to identify a storage."
+ ::= { storageEntry 1 }
+
+storageName OBJECT-TYPE
+ SYNTAX SnmpAdminString (SIZE(0..32))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Used to identify a storage medium. If the original string is longer
+ than the specified length then the middle of the string will be
+ replaced by '..' in such a way that the length of the string becomes 32
+ characters anyway."
+ ::= { storageEntry 2 }
+
+storageDisruptionDetected OBJECT-TYPE
+ SYNTAX INTEGER { no(1), yes(2) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The status of the storage medium."
+ ::= { storageEntry 3 }
+
+--- { videoObjects 9 }, reserved for tampering
+
+-- Objects used in Private Enterprise Traps
+videoNotifications OBJECT IDENTIFIER
+ ::= { video 2 }
+
+videoNotificationPrefix OBJECT IDENTIFIER
+ ::= { videoNotifications 0 }
+
+alarmID OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS accessible-for-notify
+ STATUS current
+ DESCRIPTION
+ "This object indentifies a certain alarm event in a unique way.
+ This means that there cannot be any alarm event that has the same ID
+ during a finite period of time."
+ ::= { videoNotifications 1 }
+
+alarmName OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS accessible-for-notify
+ STATUS current
+ DESCRIPTION
+ "A string that identifies which kind of alarm this is. During a certain
+ time it is possible that alarms with the same name occur."
+ ::= { videoNotifications 2 }
+
+alarmText OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS accessible-for-notify
+ STATUS current
+ DESCRIPTION
+ "Detailed description of the alarm."
+ ::= { videoNotifications 3 }
+
+videoConformance OBJECT IDENTIFIER
+ ::= { video 3 }
+
+videoGroups OBJECT IDENTIFIER
+ ::= { videoConformance 1 }
+
+videoCompliances OBJECT IDENTIFIER
+ ::= { videoConformance 2 }
+
+alarmNew NOTIFICATION-TYPE
+ OBJECTS { alarmID, alarmName, alarmText }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when a new Alarm is
+ generated that has a corresponding cleared state."
+ ::= { videoNotificationPrefix 1 }
+
+alarmCleared NOTIFICATION-TYPE
+ OBJECTS { alarmID, alarmName, alarmText }
+ STATUS current
+ DESCRIPTION
+ "This notification is generated when an alarm is
+ cleared that was previous sent as a new Alarm."
+ ::= { videoNotificationPrefix 2 }
+
+alarmSingle NOTIFICATION-TYPE
+ OBJECTS { alarmID, alarmName, alarmText }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when a new Alarm is
+ generated that has no corresponding cleared state."
+ ::= { videoNotificationPrefix 3 }
+
+-- Groups
+videoObjectGroup OBJECT-GROUP
+ OBJECTS { powerSupplyStatus, fanStatus, tempSensorStatus,
+ tempSensorValue, videoSignalStatus, audioSignalStatus,
+ casingName, casingStatus, storageDisruptionDetected,
+ storageName, alarmID, alarmName, alarmText }
+ STATUS obsolete
+ DESCRIPTION
+ "A collection of video objects."
+ ::= { videoGroups 1 }
+
+videoNotificationGroup NOTIFICATION-GROUP
+ NOTIFICATIONS { alarmNew, alarmCleared, alarmSingle }
+ STATUS current
+ DESCRIPTION
+ "A collection of video notifications."
+ ::= { videoGroups 2 }
+
+tempSensorGroup OBJECT-GROUP
+ OBJECTS { tempSensorStatus, tempSensorValue }
+ STATUS current
+ DESCRIPTION
+ "Objects related to Axis temperature sensors."
+ ::= { videoGroups 3 }
+
+casingGroup OBJECT-GROUP
+ OBJECTS { casingName, casingStatus }
+ STATUS current
+ DESCRIPTION
+ "Objects related to Axis casing."
+ ::= { videoGroups 4 }
+
+storageGroup OBJECT-GROUP
+ OBJECTS { storageDisruptionDetected, storageName }
+ STATUS current
+ DESCRIPTION
+ "Objects related to Axis storage."
+ ::= { videoGroups 5 }
+
+-- Compliance Statements
+videoComplianceRev2 MODULE-COMPLIANCE
+ STATUS current
+ DESCRIPTION
+ "The compliance statement for Axis video entities."
+
+ MODULE -- this module
+
+ MANDATORY-GROUPS { videoNotificationGroup }
+
+ GROUP powerSupplyStatus
+ DESCRIPTION
+ "This group is mandatory for all AXIS video products that have
+ redundant power supply for backup, for which it is possible to
+ check whether it is still working."
+
+ GROUP fanStatus
+ DESCRIPTION
+ "This group is mandatory for all AXIS video products that have
+ fans, for which the state can be obtained."
+
+ GROUP tempSensorGroup
+ DESCRIPTION
+ "This group is mandatory for all AXIS video products that have
+ temperature sensors, for which a state can be obtained."
+
+ GROUP videoSignalStatus
+ DESCRIPTION
+ "This group is mandatory for all AXIS video products that have
+ video cameras connected for which it is possible to check the
+ connection state. Typically this is an encoder product."
+
+ GROUP audioSignalStatus
+ DESCRIPTION
+ "This group is mandatory for all AXIS video products to which a
+ a microphone can be connected, for which the state can be
+ detected."
+
+ GROUP casingGroup
+ DESCRIPTION
+ "This group is mandatory for all AXIS video products that have
+ a casing box, for which it is possible to check the status."
+
+ GROUP storageGroup
+ DESCRIPTION
+ "This group is mandatory for all AXIS video products that have a
+ storage device connected and for which it is possible to check the
+ state."
+
+ ::= { videoCompliances 2 }
+
+videoCompliance MODULE-COMPLIANCE
+ STATUS obsolete
+ DESCRIPTION
+ "The compliance statement in a previous version of this MIB for Axis
+ video entities."
+
+ MODULE -- this module
+
+ MANDATORY-GROUPS { videoObjectGroup }
+
+ GROUP videoNotificationGroup
+ DESCRIPTION
+ "This group doesn't need to be supported."
+
+ ::= { videoCompliances 1 }
+
+END -- end of module AXIS-VIDEO-MIB.