summaryrefslogtreecommitdiff
path: root/MIBS/brocade/FOUNDRY-SN-IPX-MIB
diff options
context:
space:
mode:
authorDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
committerDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
commit98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch)
tree9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/brocade/FOUNDRY-SN-IPX-MIB
downloadmibs-main.tar.gz
mibs-main.zip
Initial commitHEADmain
Diffstat (limited to 'MIBS/brocade/FOUNDRY-SN-IPX-MIB')
-rw-r--r--MIBS/brocade/FOUNDRY-SN-IPX-MIB1361
1 files changed, 1361 insertions, 0 deletions
diff --git a/MIBS/brocade/FOUNDRY-SN-IPX-MIB b/MIBS/brocade/FOUNDRY-SN-IPX-MIB
new file mode 100644
index 0000000..4abc3df
--- /dev/null
+++ b/MIBS/brocade/FOUNDRY-SN-IPX-MIB
@@ -0,0 +1,1361 @@
+FOUNDRY-SN-IPX-MIB DEFINITIONS ::= BEGIN
+
+IMPORTS
+ MODULE-IDENTITY, OBJECT-TYPE,Counter32,Integer32
+ FROM SNMPv2-SMI
+ TEXTUAL-CONVENTION
+ FROM SNMPv2-TC
+ router
+ FROM FOUNDRY-SN-ROOT-MIB
+ PhysAddress
+ FROM FOUNDRY-SN-SWITCH-GROUP-MIB;
+
+snIpx MODULE-IDENTITY
+ LAST-UPDATED "201006020000Z" -- 04 June 2010
+ ORGANIZATION "Brocade Communications Systems, Inc."
+ CONTACT-INFO
+ "Technical Support Center
+ 130 Holger Way,
+ San Jose, CA 95134
+ Email: ipsupport@brocade.com
+ Phone: 1-800-752-8061
+ URL: www.brocade.com"
+ DESCRIPTION
+ "Copyright 1996-2010 Brocade Communications Systems, Inc.
+ All rights reserved.
+ This Brocade Communications Systems SNMP Management Information Base Specification
+ embodies Brocade Communications Systems' confidential and proprietary
+ intellectual property. Brocade Communications Systems retains all
+ title and ownership in the Specification, including any revisions.
+
+ This Specification is supplied AS IS, and Brocade Communications Systems makes
+ no warranty, either express or implied, as to the use,
+ operation, condition, or performance of the specification, and any unintended
+ consequence it may on the user environment."
+
+ REVISION "201006020000Z" -- 04 June 2010
+ DESCRIPTION
+ "Changed the ORGANIZATION, CONTACT-INFO and DESCRIPTION fields."
+
+ REVISION "200909300000Z" -- September 30, 2009
+ DESCRIPTION
+ "convert from SMIv1 to SMIv2"
+ ::= { router 1 }
+ -- textual conventions
+
+ RtrStatus ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "
+ RtrStatus Values
+ "
+ SYNTAX INTEGER { disabled(0), enabled (1) }
+
+
+
+ ClearStatus ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "
+ Clear Status Values
+ "
+ SYNTAX INTEGER { normal(0), clear(1) }
+
+
+ PortIndex ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "
+ The bits 0-7 = port number.
+ The bits 8-15 = slot number (slot for chassis only).
+ ve port format bits 16-24 = 0x01, bits 0-15 = ve number
+ loopback port format bits 16-24 = 0x02, bits 0-15= lb number
+ "
+ SYNTAX Integer32(1..3900)
+
+
+ Action ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "
+ Represents a action value such as deny or permit.
+ "
+ SYNTAX INTEGER { deny(0), permit(1) }
+
+ NetNumber::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "
+ "
+ SYNTAX OCTET STRING (SIZE(4))
+
+-- SECTION 2: MIB
+
+-- Router IPX MIB
+
+snIpxGen OBJECT IDENTIFIER ::= { snIpx 1 }
+snIpxCache OBJECT IDENTIFIER ::= { snIpx 2 }
+snIpxRoute OBJECT IDENTIFIER ::= { snIpx 3 }
+snIpxServer OBJECT IDENTIFIER ::= { snIpx 4 }
+snIpxFwdFilter OBJECT IDENTIFIER ::= { snIpx 5 }
+snIpxRipFilter OBJECT IDENTIFIER ::= { snIpx 6 }
+snIpxSapFilter OBJECT IDENTIFIER ::= { snIpx 7 }
+snIpxIfFwdAccess OBJECT IDENTIFIER ::= { snIpx 8 }
+snIpxIfRipAccess OBJECT IDENTIFIER ::= { snIpx 9 }
+snIpxIfSapAccess OBJECT IDENTIFIER ::= { snIpx 10 }
+snIpxPortAddr OBJECT IDENTIFIER ::= { snIpx 11 }
+snIpxPortCounters OBJECT IDENTIFIER ::= { snIpx 12 }
+
+-- IPX General MIBs
+
+snIpxRoutingMode OBJECT-TYPE
+ SYNTAX RtrStatus
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enabled/Disabled System IPX Routing Mode status."
+ ::= { snIpxGen 1 }
+
+snIpxNetBiosFilterMode OBJECT-TYPE
+ SYNTAX RtrStatus
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enabled/Disabled NetBios Filter Mode status."
+ ::= { snIpxGen 2 }
+
+
+snIpxClearCache OBJECT-TYPE
+ SYNTAX ClearStatus
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "clear(1) will clear cache table."
+ ::= { snIpxGen 3 }
+
+snIpxClearRoute OBJECT-TYPE
+ SYNTAX ClearStatus
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "clear(1) will clear ipx route table."
+ ::= { snIpxGen 4 }
+
+snIpxClearTrafficCnts OBJECT-TYPE
+ SYNTAX ClearStatus
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "clear(1) will clear ipx all traffic counters.
+ - snIpxRcvPktsCnt, snIpxFwdPktsCnt,
+ snIpxRcvDropPktsCnt, snIpxTxDropPktsCnt,
+ snIpxRcvFiltPktsCnt, snIpxTxFiltPktsCnt."
+ ::= { snIpxGen 5 }
+
+
+snIpxRcvPktsCnt OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "IPX incoming packets counter."
+ ::= { snIpxGen 6 }
+
+
+snIpxTxPktsCnt OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "IPX Outgoing packets counter."
+ ::= { snIpxGen 7 }
+
+
+snIpxFwdPktsCnt OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "IPX forwarding packets counter."
+ ::= { snIpxGen 8 }
+
+snIpxRcvDropPktsCnt OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "IPX receiving drop packets counter."
+ ::= { snIpxGen 9 }
+
+snIpxRcvFiltPktsCnt OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "IPX receiving filter packets counter."
+ ::= { snIpxGen 10 }
+
+snIpxRipGblFiltList OBJECT-TYPE
+ SYNTAX OCTET STRING(SIZE(0..32))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "An IPX RIP Global Filter List. Null value indicates no filter list."
+ ::= { snIpxGen 11 }
+
+snIpxRipFiltOnAllPort OBJECT-TYPE
+ SYNTAX INTEGER {
+ valid(1),
+ deleteAllInBound(2),
+ deleteAllOutBound(3),
+ addAllInBound(4),
+ addAllOutBound(5)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Apply the IPX RIP Global filter list snIpxRipGblFiltList to
+ all interfaces. This object is used to add all RIP filter
+ lists and delete all RIP filter lists to/from all ports.
+ Prior to sending this command, snIpxRipGblFiltList must be ready.
+ The values that can be written are:
+ deleteAllInBound(2)...delete all in-bound filter lists from all ports.
+ deleteAllOutBound(3)..delete all out-bound filter lists from all ports.
+ addAllInBound(4)......add all in-bound filter lists to all ports.
+ addAllOutBound(5).....add all out-bound filter lists to all ports.
+
+ If set operation is failed, then a SET with
+ value of (2)or(3) returns error 'GenError'.
+ Deleted(2)&(3) go away immediately.
+ The following values can be returned on reads:
+ noSuch(0)...no such operation yet.
+ valid(1)....set operation is done and is valid"
+
+ ::= { snIpxGen 12 }
+
+snIpxSapGblFiltList OBJECT-TYPE
+ SYNTAX OCTET STRING(SIZE(0..32))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "An IPX SAP Global Filter List. Null value indicates no filter list"
+ ::= { snIpxGen 13 }
+
+
+snIpxSapFiltOnAllPort OBJECT-TYPE
+ SYNTAX INTEGER {
+ valid(1),
+ deleteAllInBound(2),
+ deleteAllOutBound(3),
+ addAllInBound(4),
+ addAllOutBound(5)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Apply the IPX SAP Global filter list snIpxSapGblFiltList to
+ all interfaces. This object is used to add all RIP filter
+ lists and delete all SAP filter lists to/from all ports.
+ Prior to sending this command, snIpxSapGblFiltList must be ready.
+ The values that can be written are:
+ deleteAllInBound(2)...delete all in-bound filter lists from all ports.
+ deleteAllOutBound(3)..delete all out-bound filter lists from all ports.
+ addAllInBound(4)......add all in-bound filter lists to all ports.
+ addAllOutBound(5).....add all out-bound filter lists to all ports.
+
+ If set operation is failed, then a SET with
+ value of (2)or(3) returns error 'GenError'.
+ Deleted(2)&(3) go away immediately.
+ The following values can be returned on reads:
+ noSuch(0)...no such operation yet.
+ valid(1)....set operation is done and is valid"
+ ::= { snIpxGen 14 }
+
+snIpxTxDropPktsCnt OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "IPX transmitting drop packets counter."
+ ::= { snIpxGen 15 }
+
+snIpxTxFiltPktsCnt OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "IPX transmitting filter packets counter."
+ ::= { snIpxGen 16 }
+
+
+-- IPX Cache table
+
+snIpxCacheTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SnIpxCacheEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "IPX Cache table."
+ ::= { snIpxCache 1 }
+
+snIpxCacheEntry OBJECT-TYPE
+ SYNTAX SnIpxCacheEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry in the IPX Cache table."
+ INDEX { snIpxCacheIndex }
+ ::= { snIpxCacheTable 1 }
+
+SnIpxCacheEntry ::= SEQUENCE {
+ snIpxCacheIndex
+ Integer32,
+ snIpxCacheNetNum
+ NetNumber,
+ snIpxCacheNode
+ PhysAddress,
+ snIpxCacheOutFilter
+ RtrStatus,
+ snIpxCacheEncap
+ INTEGER,
+ snIpxCachePort
+ PortIndex
+ }
+
+snIpxCacheIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The table index for a IPX Cache entry."
+ ::= { snIpxCacheEntry 1 }
+
+
+snIpxCacheNetNum OBJECT-TYPE
+ SYNTAX NetNumber
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cache Network number."
+ ::= { snIpxCacheEntry 2 }
+
+snIpxCacheNode OBJECT-TYPE
+ SYNTAX PhysAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cache Node Number."
+ ::= { snIpxCacheEntry 3 }
+
+snIpxCacheOutFilter OBJECT-TYPE
+ SYNTAX RtrStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cache Outbound Filter is ether disabled(0) or enabled(1)."
+ ::= { snIpxCacheEntry 4 }
+
+snIpxCacheEncap OBJECT-TYPE
+ SYNTAX INTEGER {
+ ethernetII(1),
+ ethernet8022(2),
+ ethernet8023(3),
+ ethernetSnap(4)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The IPX encapsulation frame type."
+ ::= { snIpxCacheEntry 5 }
+
+
+snIpxCachePort OBJECT-TYPE
+ SYNTAX PortIndex
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "IPX Router Port number."
+ ::= { snIpxCacheEntry 6 }
+
+
+
+
+-- IPX route table
+
+snIpxRouteTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SnIpxRouteEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "IPX route table."
+ ::= { snIpxRoute 1 }
+
+snIpxRouteEntry OBJECT-TYPE
+ SYNTAX SnIpxRouteEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry in the IPX route table."
+ INDEX { snIpxRouteIndex }
+ ::= { snIpxRouteTable 1 }
+
+SnIpxRouteEntry ::= SEQUENCE {
+ snIpxRouteIndex
+ Integer32,
+ snIpxDestNetNum
+ NetNumber,
+ snIpxFwdRouterNode
+ PhysAddress,
+ snIpxDestHopCnts
+ Integer32,
+ snIpxRouteMetric
+ Integer32,
+ snIpxDestPort
+ Integer32
+ }
+
+snIpxRouteIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The table index for a IPX route entry."
+ ::= { snIpxRouteEntry 1 }
+
+snIpxDestNetNum OBJECT-TYPE
+ SYNTAX NetNumber
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Destination Network number."
+ ::= { snIpxRouteEntry 2 }
+
+snIpxFwdRouterNode OBJECT-TYPE
+ SYNTAX PhysAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Forward Router Node Number."
+ ::= { snIpxRouteEntry 3 }
+
+snIpxDestHopCnts OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of hops to reach the
+ destination."
+ ::= { snIpxRouteEntry 4 }
+
+snIpxRouteMetric OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The metrics to next hop router."
+ ::= { snIpxRouteEntry 5 }
+
+snIpxDestPort OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The destination port."
+ ::= { snIpxRouteEntry 6 }
+
+
+-- IPX Server table
+
+snIpxServerTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SnIpxServerEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "IPX Server table."
+ ::= { snIpxServer 1 }
+
+snIpxServerEntry OBJECT-TYPE
+ SYNTAX SnIpxServerEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry in the IPX Server table."
+ INDEX { snIpxServerIndex }
+ ::= { snIpxServerTable 1 }
+
+SnIpxServerEntry ::= SEQUENCE {
+ snIpxServerIndex
+ Integer32,
+ snIpxServerType
+ Integer32,
+ snIpxServerNetNum
+ NetNumber,
+ snIpxServerNode
+ PhysAddress,
+ snIpxServerSocket
+ Integer32,
+ snIpxServerHopCnts
+ Integer32,
+ snIpxServerName
+ OCTET STRING
+ }
+
+snIpxServerIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The table index for a IPX Server entry."
+ ::= { snIpxServerEntry 1 }
+
+
+snIpxServerType OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "IPX Server Type."
+ ::= { snIpxServerEntry 2 }
+
+snIpxServerNetNum OBJECT-TYPE
+ SYNTAX NetNumber
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Server Network number."
+ ::= { snIpxServerEntry 3 }
+
+snIpxServerNode OBJECT-TYPE
+ SYNTAX PhysAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Server Node Number."
+ ::= { snIpxServerEntry 4 }
+
+snIpxServerSocket OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Server Socket Number."
+ ::= { snIpxServerEntry 5 }
+
+snIpxServerHopCnts OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of intervening networks to reach the
+ server."
+ ::= { snIpxServerEntry 6 }
+
+
+snIpxServerName OBJECT-TYPE
+ SYNTAX OCTET STRING(SIZE(0..47))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "IPX Server Name."
+ ::= { snIpxServerEntry 7 }
+
+
+
+-- IPX Forward Filter table
+
+snIpxFwdFilterTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SnIpxFwdFilterEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "IPX Forward Filter table."
+ ::= { snIpxFwdFilter 1 }
+
+snIpxFwdFilterEntry OBJECT-TYPE
+ SYNTAX SnIpxFwdFilterEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry in the IPX Forward Filter table."
+ INDEX { snIpxFwdFilterIdx }
+ ::= { snIpxFwdFilterTable 1 }
+
+SnIpxFwdFilterEntry ::= SEQUENCE {
+ snIpxFwdFilterIdx
+ Integer32,
+ snIpxFwdFilterAction
+ Action,
+ snIpxFwdFilterSocket
+ Integer32,
+ snIpxFwdFilterSrcNet
+ NetNumber,
+ snIpxFwdFilterSrcNode
+ PhysAddress,
+ snIpxFwdFilterDestNet
+ NetNumber,
+ snIpxFwdFilterDestNode
+ PhysAddress,
+ snIpxFwdFilterRowStatus
+ INTEGER
+ }
+
+snIpxFwdFilterIdx OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The filter ID for a filter entry."
+ ::= { snIpxFwdFilterEntry 1 }
+
+snIpxFwdFilterAction OBJECT-TYPE
+ SYNTAX Action
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Action to take if the ipx packet match
+ with this filter."
+ ::= { snIpxFwdFilterEntry 2 }
+
+snIpxFwdFilterSocket OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "IPX Forward Filter Socket Number."
+ ::= { snIpxFwdFilterEntry 3 }
+
+snIpxFwdFilterSrcNet OBJECT-TYPE
+ SYNTAX NetNumber
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Source Network Number."
+ ::= { snIpxFwdFilterEntry 4 }
+
+snIpxFwdFilterSrcNode OBJECT-TYPE
+ SYNTAX PhysAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Source Node Number."
+ ::= { snIpxFwdFilterEntry 5 }
+
+snIpxFwdFilterDestNet OBJECT-TYPE
+ SYNTAX NetNumber
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Destination Network Number."
+ ::= { snIpxFwdFilterEntry 6 }
+
+snIpxFwdFilterDestNode OBJECT-TYPE
+ SYNTAX PhysAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Destination Node Number."
+ ::= { snIpxFwdFilterEntry 7 }
+
+snIpxFwdFilterRowStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ invalid(1),
+ valid(2),
+ delete(3),
+ create(4),
+ modify(5)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object is used to create and
+ delete row in the table and control
+ if they are used. The values
+ that can be written are:
+ delete(3)...deletes the row
+ create(4)...creates a new row
+ modify(5)...modifies an exsisting row
+
+ If the row exists, then a SET with
+ value of create(4) returns error
+ 'badValue'. Deleted rows go away
+ immediately. The following values
+ can be returned on reads:
+ noSuch(0)...no such row
+ invalid(1)...Setting it to 'invalid' has the effect of
+ rendering it inoperative..
+ valid(2)....the row exists and is valid"
+ ::= { snIpxFwdFilterEntry 8 }
+
+
+
+-- IPX RIP Filter table
+
+snIpxRipFilterTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SnIpxRipFilterEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "IPX RIP Filter table."
+ ::= { snIpxRipFilter 1 }
+
+snIpxRipFilterEntry OBJECT-TYPE
+ SYNTAX SnIpxRipFilterEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry in the IPX RIP Filter table."
+ INDEX { snIpxRipFilterId }
+ ::= { snIpxRipFilterTable 1 }
+
+SnIpxRipFilterEntry ::= SEQUENCE {
+ snIpxRipFilterId
+ Integer32,
+ snIpxRipFilterAction
+ Action,
+ snIpxRipFilterNet
+ NetNumber,
+ snIpxRipFilterMask
+ NetNumber,
+ snIpxRipFilterRowStatus
+ INTEGER
+ }
+
+snIpxRipFilterId OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The filter ID for a filter entry."
+ ::= { snIpxRipFilterEntry 1 }
+
+snIpxRipFilterAction OBJECT-TYPE
+ SYNTAX Action
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Action to take if the ipx packet match
+ with this filter."
+ ::= { snIpxRipFilterEntry 2 }
+
+snIpxRipFilterNet OBJECT-TYPE
+ SYNTAX NetNumber
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "IPX RIP Filter Network number."
+ ::= { snIpxRipFilterEntry 3 }
+
+snIpxRipFilterMask OBJECT-TYPE
+ SYNTAX NetNumber
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "IPX RIP Filter Network/Subnet Mask."
+ ::= { snIpxRipFilterEntry 4 }
+
+
+snIpxRipFilterRowStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ invalid(1),
+ valid(2),
+ delete(3),
+ create(4),
+ modify(5)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object is used to create and
+ delete row in the table and control
+ if they are used. The values
+ that can be written are:
+ delete(3)...deletes the row
+ create(4)...creates a new row
+ modify(5)...modifies an exsisting row
+
+ If the row exists, then a SET with
+ value of create(4) returns error
+ 'badValue'. Deleted rows go away
+ immediately. The following values
+ can be returned on reads:
+ noSuch(0)...no such row
+ invalid(1)...Setting it to 'invalid' has the effect of
+ rendering it inoperative..
+ valid(2)....the row exists and is valid"
+ ::= { snIpxRipFilterEntry 5 }
+
+
+
+-- IPX SAP Filter table
+
+snIpxSapFilterTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SnIpxSapFilterEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "IPX SAP Filter table."
+ ::= { snIpxSapFilter 1 }
+
+snIpxSapFilterEntry OBJECT-TYPE
+ SYNTAX SnIpxSapFilterEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry in the IPX SAP Filter table."
+ INDEX { snIpxSapFilterId }
+ ::= { snIpxSapFilterTable 1 }
+
+SnIpxSapFilterEntry ::= SEQUENCE {
+ snIpxSapFilterId
+ Integer32,
+ snIpxSapFilterAction
+ Action,
+ snIpxSapFilterType
+ Integer32,
+ snIpxSapFilterName
+ OCTET STRING,
+ snIpxSapFilterRowStatus
+ INTEGER
+ }
+
+snIpxSapFilterId OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The filter ID for a filter entry."
+ ::= { snIpxSapFilterEntry 1 }
+
+snIpxSapFilterAction OBJECT-TYPE
+ SYNTAX Action
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Action to take if the ipx packet match
+ with this filter."
+ ::= { snIpxSapFilterEntry 2 }
+
+snIpxSapFilterType OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "IPX SAP Filter type to be matched."
+ ::= { snIpxSapFilterEntry 3 }
+
+snIpxSapFilterName OBJECT-TYPE
+ SYNTAX OCTET STRING(SIZE(0..47))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "IPX SAP Filter Name."
+ ::= { snIpxSapFilterEntry 4 }
+
+
+snIpxSapFilterRowStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ invalid(1),
+ valid(2),
+ delete(3),
+ create(4),
+ modify(5)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object is used to create and
+ delete row in the table and control
+ if they are used. The values
+ that can be written are:
+ delete(3)...deletes the row
+ create(4)...creates a new row
+ modify(5)...modifies an exsisting row
+
+ If the row exists, then a SET with
+ value of create(4) returns error
+ 'badValue'. Deleted rows go away
+ immediately. The following values
+ can be returned on reads:
+ noSuch(0)...no such row
+ invalid(1)...Setting it to 'invalid' has the effect of
+ rendering it inoperative..
+ valid(2)....the row exists and is valid"
+ ::= { snIpxSapFilterEntry 5 }
+
+
+-- IPX IF Forward Access table
+
+snIpxIfFwdAccessTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SnIpxIfFwdAccessEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "IPX IF Forward Access table."
+ ::= { snIpxIfFwdAccess 1 }
+
+snIpxIfFwdAccessEntry OBJECT-TYPE
+ SYNTAX SnIpxIfFwdAccessEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry in the IPX Forward Access table."
+ INDEX { snIpxIfFwdAccessPort, snIpxIfFwdAccessDir }
+ ::= { snIpxIfFwdAccessTable 1 }
+
+SnIpxIfFwdAccessEntry ::= SEQUENCE {
+ snIpxIfFwdAccessPort
+ Integer32,
+ snIpxIfFwdAccessDir
+ INTEGER,
+ snIpxIfFwdAccessFilterList
+ OCTET STRING,
+ snIpxIfFwdAccessRowStatus
+ INTEGER
+ }
+
+snIpxIfFwdAccessPort OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The IPX interface to which the Forward Filter applies."
+ ::= { snIpxIfFwdAccessEntry 1 }
+
+snIpxIfFwdAccessDir OBJECT-TYPE
+ SYNTAX INTEGER { in(1), out(2) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The access direction of incoming packet filter
+ or outgoing packet filter."
+ ::= { snIpxIfFwdAccessEntry 2 }
+
+snIpxIfFwdAccessFilterList OBJECT-TYPE
+ SYNTAX OCTET STRING(SIZE(1..32))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "An IPX IF Forward Filter List."
+ ::= { snIpxIfFwdAccessEntry 3 }
+
+
+snIpxIfFwdAccessRowStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ invalid(1),
+ valid(2),
+ delete(3),
+ create(4),
+ modify(5)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object is used to create and
+ delete row in the table and control
+ if they are used. The values
+ that can be written are:
+ delete(3)...deletes the row
+ create(4)...creates a new row
+ modify(5)...modifies an exsisting row
+
+ If the row exists, then a SET with
+ value of create(4) returns error
+ 'badValue'. Deleted rows go away
+ immediately. The following values
+ can be returned on reads:
+ noSuch(0)...no such row
+ invalid(1)...Setting it to 'invalid' has the effect of
+ rendering it inoperative..
+ valid(2)....the row exists and is valid"
+ ::= { snIpxIfFwdAccessEntry 4 }
+
+
+
+-- IPX IF RIP Access table
+
+snIpxIfRipAccessTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SnIpxIfRipAccessEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "IPX IF RIP Access table."
+ ::= { snIpxIfRipAccess 1 }
+
+snIpxIfRipAccessEntry OBJECT-TYPE
+ SYNTAX SnIpxIfRipAccessEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry in the IPX Forward Access table."
+ INDEX { snIpxIfRipAccessPort, snIpxIfRipAccessDir }
+ ::= { snIpxIfRipAccessTable 1 }
+
+SnIpxIfRipAccessEntry ::= SEQUENCE {
+ snIpxIfRipAccessPort
+ Integer32,
+ snIpxIfRipAccessDir
+ INTEGER,
+ snIpxIfRipAccessFilterList
+ OCTET STRING,
+ snIpxIfRipAccessRowStatus
+ INTEGER
+ }
+
+snIpxIfRipAccessPort OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The IPX interface to which the RIP Filter applies."
+ ::= { snIpxIfRipAccessEntry 1 }
+
+snIpxIfRipAccessDir OBJECT-TYPE
+ SYNTAX INTEGER { in(1), out(2) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The access direction of incoming packet filter
+ or outgoing packet filter."
+ ::= { snIpxIfRipAccessEntry 2 }
+
+snIpxIfRipAccessFilterList OBJECT-TYPE
+ SYNTAX OCTET STRING(SIZE(1..32))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "An IPX IF RIP Access Filter List."
+ ::= { snIpxIfRipAccessEntry 3 }
+
+
+snIpxIfRipAccessRowStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ invalid(1),
+ valid(2),
+ delete(3),
+ create(4),
+ modify(5)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object is used to create and
+ delete row in the table and control
+ if they are used. The values
+ that can be written are:
+ delete(3)...deletes the row
+ create(4)...creates a new row
+ modify(5)...modifies an exsisting row
+
+ If the row exists, then a SET with
+ value of create(4) returns error
+ 'badValue'. Deleted rows go away
+ immediately. The following values
+ can be returned on reads:
+ noSuch(0)...no such row
+ invalid(1)...Setting it to 'invalid' has the effect of
+ rendering it inoperative..
+ valid(2)....the row exists and is valid"
+ ::= { snIpxIfRipAccessEntry 4 }
+
+
+-- IPX IF SAP Access table
+
+snIpxIfSapAccessTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SnIpxIfSapAccessEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "IPX IF RIP Access table."
+ ::= { snIpxIfSapAccess 1 }
+
+snIpxIfSapAccessEntry OBJECT-TYPE
+ SYNTAX SnIpxIfSapAccessEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry in the IPX Forward Access table."
+ INDEX { snIpxIfSapAccessPort, snIpxIfSapAccessDir }
+ ::= { snIpxIfSapAccessTable 1 }
+
+SnIpxIfSapAccessEntry ::= SEQUENCE {
+ snIpxIfSapAccessPort
+ Integer32,
+ snIpxIfSapAccessDir
+ INTEGER,
+ snIpxIfSapAccessFilterList
+ OCTET STRING,
+ snIpxIfSapAccessRowStatus
+ INTEGER
+ }
+
+snIpxIfSapAccessPort OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The IPX interface to which the SAP Filter applies."
+ ::= { snIpxIfSapAccessEntry 1 }
+
+snIpxIfSapAccessDir OBJECT-TYPE
+ SYNTAX INTEGER { in(1), out(2) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The access direction of incoming packet filter
+ or outgoing packet filter."
+ ::= { snIpxIfSapAccessEntry 2 }
+
+snIpxIfSapAccessFilterList OBJECT-TYPE
+ SYNTAX OCTET STRING(SIZE(1..32))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "An IPX IF SAP Access Filter List."
+ ::= { snIpxIfSapAccessEntry 3 }
+
+
+snIpxIfSapAccessRowStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ invalid(1),
+ valid(2),
+ delete(3),
+ create(4),
+ modify(5)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object is used to create and
+ delete row in the table and control
+ if they are used. The values
+ that can be written are:
+ delete(3)...deletes the row
+ create(4)...creates a new row
+ modify(5)...modifies an exsisting row
+
+ If the row exists, then a SET with
+ value of create(4) returns error
+ 'badValue'. Deleted rows go away
+ immediately. The following values
+ can be returned on reads:
+ noSuch(0)...no such row
+ invalid(1)...Setting it to 'invalid' has the effect of
+ rendering it inoperative..
+ valid(2)....the row exists and is valid"
+ ::= { snIpxIfSapAccessEntry 4 }
+
+
+-- ipx interface address table
+
+snIpxPortAddrTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SnIpxPortAddrEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "IPX port address table."
+ ::= { snIpxPortAddr 1 }
+
+snIpxPortAddrEntry OBJECT-TYPE
+ SYNTAX SnIpxPortAddrEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry in the IPX Port Address table."
+ INDEX { snIpxPortAddrPort, snIpxPortAddrEncap }
+ ::= { snIpxPortAddrTable 1 }
+
+SnIpxPortAddrEntry ::= SEQUENCE {
+ snIpxPortAddrPort
+ PortIndex,
+ snIpxPortAddrEncap
+ INTEGER,
+ snIpxPortAddrNetNum
+ NetNumber,
+ snIpxPortAddrRowStatus
+ INTEGER,
+ snIpxPortAddrNetBiosFilterMode
+ RtrStatus
+ }
+
+
+snIpxPortAddrPort OBJECT-TYPE
+ SYNTAX PortIndex
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The port index for port address entry."
+ ::= { snIpxPortAddrEntry 1 }
+
+snIpxPortAddrEncap OBJECT-TYPE
+ SYNTAX INTEGER {
+ ethernet8022(1),
+ ethernet8023(2),
+ ethernetII(3),
+ ethernetSnap(4)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The IPX encapsulation type.
+ ethernet8022(1), ethernet8023(2),
+ ethernetII(3), ethernetSnap(4)
+ Note: Each Network Number can be assigned with one unique Frame type; Otherwise,
+ a SNMP-SET error will be returned."
+ ::= { snIpxPortAddrEntry 2 }
+
+snIpxPortAddrNetNum OBJECT-TYPE
+ SYNTAX NetNumber
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "An unique Network number for the IPX interface port."
+ ::= { snIpxPortAddrEntry 3 }
+
+snIpxPortAddrRowStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ invalid(1),
+ valid(2),
+ delete(3),
+ create(4),
+ modify(5)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object is used to create and
+ delete row in the table and control
+ if they are used. The values
+ that can be written are:
+ delete(3)...deletes the row
+ create(4)...creates a new row
+ modify(5)...modifies an exsisting row
+
+ If the row exists, then a SET with
+ value of create(4) returns error
+ 'badValue'. Deleted rows go away
+ immediately. The following values
+ can be returned on reads:
+ noSuch(0)...no such row
+ invalid(1)...Setting it to 'invalid' has the effect of
+ rendering it inoperative..
+ valid(2)....the row exists and is valid"
+ ::= { snIpxPortAddrEntry 4 }
+
+snIpxPortAddrNetBiosFilterMode OBJECT-TYPE
+ SYNTAX RtrStatus
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enabled/Disabled NetBios Filter Mode status per Port Address entry."
+ ::= { snIpxPortAddrEntry 5 }
+
+
+-- ipx port counters table
+
+snIpxPortCountersTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SnIpxPortCountersEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "IPX port Counters table."
+ ::= { snIpxPortCounters 1 }
+
+snIpxPortCountersEntry OBJECT-TYPE
+ SYNTAX SnIpxPortCountersEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry in the IPX Port Counters table."
+ INDEX { snIpxPortCountersPort }
+ ::= { snIpxPortCountersTable 1 }
+
+SnIpxPortCountersEntry ::= SEQUENCE {
+ snIpxPortCountersPort
+ PortIndex,
+ snIpxPortCountersRcvPktsCnt
+ Counter32,
+ snIpxPortCountersTxPktsCnt
+ Counter32,
+ snIpxPortCountersFwdPktsCnt
+ Counter32,
+ snIpxPortCountersRcvDropPktsCnt
+ Counter32,
+ snIpxPortCountersTxDropPktsCnt
+ Counter32,
+ snIpxPortCountersRcvFiltPktsCnt
+ Counter32,
+ snIpxPortCountersTxFiltPktsCnt
+ Counter32
+ }
+
+
+snIpxPortCountersPort OBJECT-TYPE
+ SYNTAX PortIndex
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The port index for port Counters entry."
+ ::= { snIpxPortCountersEntry 1 }
+
+snIpxPortCountersRcvPktsCnt OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "IPX incoming packets counter for the interface."
+ ::= { snIpxPortCountersEntry 2 }
+
+
+snIpxPortCountersTxPktsCnt OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "IPX Outgoing packets counter for the interface."
+ ::= { snIpxPortCountersEntry 3 }
+
+
+snIpxPortCountersFwdPktsCnt OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "IPX forwarding packets counter for the interface."
+ ::= { snIpxPortCountersEntry 4 }
+
+snIpxPortCountersRcvDropPktsCnt OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "IPX receiving drop packets counter for the interface."
+ ::= { snIpxPortCountersEntry 5 }
+
+snIpxPortCountersTxDropPktsCnt OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "IPX transmitting drop packets counter for the interface."
+ ::= { snIpxPortCountersEntry 6 }
+
+snIpxPortCountersRcvFiltPktsCnt OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "IPX receiving filter packets counter for the interface."
+ ::= { snIpxPortCountersEntry 7 }
+
+snIpxPortCountersTxFiltPktsCnt OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "IPX transmitting filter packets counter for the interface."
+ ::= { snIpxPortCountersEntry 8 }
+
+
+
+END
+