diff options
| author | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
|---|---|---|
| committer | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
| commit | 98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch) | |
| tree | 9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/brocade/SYSTEM-MIB | |
| download | mibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.tar.gz mibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.zip | |
Diffstat (limited to 'MIBS/brocade/SYSTEM-MIB')
| -rw-r--r-- | MIBS/brocade/SYSTEM-MIB | 1056 |
1 files changed, 1056 insertions, 0 deletions
diff --git a/MIBS/brocade/SYSTEM-MIB b/MIBS/brocade/SYSTEM-MIB new file mode 100644 index 0000000..affb029 --- /dev/null +++ b/MIBS/brocade/SYSTEM-MIB @@ -0,0 +1,1056 @@ +-- +-- Title: Switch System MIB. +-- + +SYSTEM-MIB DEFINITIONS ::= BEGIN + + IMPORTS + DisplayString, TEXTUAL-CONVENTION, TruthValue + FROM SNMPv2-TC + Integer32, OBJECT-TYPE, OBJECT-IDENTITY, + MODULE-IDENTITY + FROM SNMPv2-SMI + SwSensorIndex, SwPortIndex + FROM Brocade-TC + sw + FROM SWBASE-MIB; + + swSystem MODULE-IDENTITY + LAST-UPDATED "1104151830Z" -- Apr 15, 20i11 6:30pm + ORGANIZATION "Brocade Communications Systems, Inc.," + CONTACT-INFO "Customer Support Group + Brocade Communications Systems, + 130 Holger Way, + San Jose, CA 95134 U.S.A + Tel: +1-408-333-8000 + Fax: +1-408-333-8101 + Email: support@Brocade.COM + WEB: www.brocade.com" + + + DESCRIPTION "The MIB module is for system information. + Copyright (c) 1996-2003 Brocade Communications Systems, Inc. + All rights reserved." + REVISION "1104151830Z" -- Apr 15, 2011 6:30pm + DESCRIPTION "Initial version of this module." + REVISION "1204301800Z" -- Apr 30, 2012 6:00pm + DESCRIPTION "Added swID mib object." + ::= { sw 1 } + + swFabric OBJECT-IDENTITY + STATUS current + DESCRIPTION "The OID sub-tree for swFabric group." + ::= { sw 2 } + + -- 3..7 are reserved; should not be used for new features. + + swFCport OBJECT-IDENTITY + STATUS current + DESCRIPTION "The OID sub-tree for swFCport group." + ::= { sw 6 } + + swEvent OBJECT-IDENTITY + STATUS current + DESCRIPTION "The OID sub-tree for swEvent group." + ::= { sw 8 } + + FcPortFlag ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION "Represents the port status for a FC Flag. Currently this will indicate + if the port is virtual or physical." + SYNTAX BITS { + physical (0), + virtual (1) + } + + -- Fabric member information + -- + swVfId OBJECT-TYPE + SYNTAX Integer32 (0..255) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The Virtual fabric id." + ::= { swFabric 15 } + -- End of Fabric member information + -- + -- + -- the System Group (sw) + -- + + swCurrentDate OBJECT-TYPE + SYNTAX DisplayString(SIZE (0..64)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The current date information in displayable textual + format." + ::= { swSystem 1 } + + swBootDate OBJECT-TYPE + SYNTAX DisplayString(SIZE (0..64)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The date and time when the system last booted, in + displayable textual format." + ::= { swSystem 2 } + + swFWLastUpdated OBJECT-TYPE + SYNTAX DisplayString(SIZE (0..64)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The information indicates the date when the firmware + was last updated, in displayable textual format." + ::= { swSystem 3 } + + swFlashLastUpdated OBJECT-TYPE + SYNTAX DisplayString(SIZE (0..64)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The information indicates the date when the FLASH + was last updated, in displayable textual format." + ::= { swSystem 4 } + + swBootPromLastUpdated OBJECT-TYPE + SYNTAX DisplayString(SIZE (0..64)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The information indicates the date when the boot PROM + was last updated, in displayable textual format." + ::= { swSystem 5 } + + swFirmwareVersion OBJECT-TYPE + SYNTAX DisplayString(SIZE (0..24)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The current version of the firwmare." + ::= { swSystem 6 } + + swOperStatus OBJECT-TYPE + SYNTAX INTEGER { + online (1), + offline (2), + testing (3), + faulty (4) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The current operational status of the switch. + The states are as follow: + o online(1) means the switch is accessible by an external + port; + o offline(2) means the switch is not accessible; + o testing(3) means the switch is in a built-in test mode + and is not accessible by an external port; + o faulty(4) means the switch is not operational." + ::= { swSystem 7 } + + -- 8..9 are reserved; should not be used for new features. + + swSsn OBJECT-TYPE + SYNTAX DisplayString(SIZE (0..128)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The soft serial number of the switch." + ::= { swSystem 10 } + + + -- FLASH administration + -- the next 5 objects are related to firmware or config file management. + -- + -- The underlying method in the transfer of the firmware or config file + -- is based on either FTP or remote shell. + -- If a password is provided, then FTP is used. + -- If NO password is provided, then remote shell is used. + -- + -- 2 steps to manage firmware or switch config file in the switch FLASH, + -- (A1) set swFlashDLHost.0, swFlashDLUser.0 and swFlashDLFile.0 to + -- appropriate + -- host IP address in user dot notation (e.g. 192.168.1.7), + -- user name (e.g. "administrator"), and + -- file name of the firmware or config file (e.g. "/home/fcswh/v2.2") + -- respectively; + -- (A2) set swFlashDLPassword.0 to an appropriate value (e.g. "secret") + -- if FTP is the desired method of transfer; + -- (B) set swFlashDLAdmStatus.0 to swFwUpgrade(2), swCfUpload(3), + -- or swCfDownload(4) accordingly. + -- + + swFlashDLOperStatus OBJECT-TYPE + SYNTAX INTEGER { + unknown (0), + swCurrent (1), + swFwUpgraded (2), + swCfUploaded (3), + swCfDownloaded (4), + swFwCorrupted (5) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The operational status of the FLASH. + The operational states are as follow: + o swCurrent(1) indicates that the FLASH contains the + current firmware image or config file; + o swFwUpgraded(2) state indicates that it contains the image + upgraded from the swFlashDLHost.0.; + o swCfUploaded(3) state indicates that the switch configuration + file has been uploaded to the host; and + o swCfDownloaded(4) state indicates that the switch + configuration file has been downloaded from the host. + o swFwCorrupted (5) state indicates that the firmware in the + FLASH of the switch is corrupted." + ::= { swSystem 11 } + + swFlashDLAdmStatus OBJECT-TYPE + SYNTAX INTEGER { + swCurrent (1), + swFwUpgrade (2), + swCfUpload (3), + swCfDownload (4), + swFwCorrupted (5) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The state of the FLASH. + o swCurrent(1) indicates that the FLASH contains the + current firmware image or config file; + o swFwUpgrade(2) means that the firmware in the FLASH is to be + upgraded from the host specified; + o swCfUpload(3) means that the switch config file is to be + uploaded to the host specified; or + o swCfDownload(4) means that the switch config file is to be + downloaded from the host specified. + o swFwCorrupted(5) state indicates that the firmware in the + FLASH is corrupted. This value is for informational purpose + only. However, set of swFlashDLAdmStatus to this value is + not allowed. + + The host is specified in swFlashDLHost.0. In addition, + user name is specified in swFlashDLUser.0, and + the file name specified in swFlashDLFile.0. + + Reference the user manual on the following commands, + o firmwareDownload, + o configUpload, and + o configDownload." + ::= { swSystem 12 } + + -- 13..17 are reserved + + swBeaconOperStatus OBJECT-TYPE + SYNTAX INTEGER { + on (1), + off (2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The current operational status of the switch beacon. + When the beacon is on, the LEDs on the front panel + of the switch run alternately from left to right + and right to left. The color is yellow. + When the beacon is off, each LED will be in their + its regular status indicating color and state." + ::= { swSystem 18 } + + swBeaconAdmStatus OBJECT-TYPE + SYNTAX INTEGER { + on (1), + off (2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The desired status of the switch beacon. + When the beacon is set to on, the LEDs on the front + panel of the switch run alternately from left to right + and right to left. The color is yellow. + When the beacon is set to off, each LED will be in + its regular status indicating color and state." + ::= { swSystem 19 } + + swDiagResult OBJECT-TYPE + SYNTAX INTEGER { + sw-ok (1), + sw-faulty (2), + sw-embedded-port-fault (3) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The result of the power-on startup (POST) + diagnostics." + ::= { swSystem 20 } + + -- operating environment sensors (temperature, fan, power supply...) + swNumSensors OBJECT-TYPE + SYNTAX Integer32 (0..2147483647) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The number of sensors inside the switch." + ::= { swSystem 21 } + + swSensorTable OBJECT-TYPE + SYNTAX SEQUENCE OF SwSensorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "The table of sensor entries." + ::= { swSystem 22 } + + swSensorEntry OBJECT-TYPE + SYNTAX SwSensorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "An entry of the sensor information." + INDEX { swSensorIndex } + ::= { swSensorTable 1 } + + SwSensorEntry ::= SEQUENCE { + swSensorIndex SwSensorIndex, + swSensorType INTEGER, + swSensorStatus INTEGER, + swSensorValue Integer32, + swSensorInfo DisplayString + } + + swSensorIndex OBJECT-TYPE + SYNTAX SwSensorIndex + MAX-ACCESS read-only + STATUS current + DESCRIPTION "This object identifies the sensor." + ::= { swSensorEntry 1 } + + swSensorType OBJECT-TYPE + SYNTAX INTEGER { + temperature (1), + fan (2), + power-supply (3) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION "This object identifies the sensor type." + ::= { swSensorEntry 2 } + + swSensorStatus OBJECT-TYPE + SYNTAX INTEGER { + unknown (1), + faulty (2), + below-min (3), + nominal (4), + above-max (5), + absent (6) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The current status of the sensor." + ::= { swSensorEntry 3 } + + swSensorValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The current value (reading) of the sensor. + The value, -2147483648, represents an unknown quantity. + It also means that the sensor does not have the capability to + measure the actual value. In V2.0, the temperature sensor + value will be in Celsius; the fan value will be in RPM + (revolution per minute); and the power supply sensor reading + will be unknown." + ::= { swSensorEntry 4 } + + swSensorInfo OBJECT-TYPE + SYNTAX DisplayString(SIZE(0..255)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Additional displayable information on the sensor. + In V2.x, it contains the sensor type and number + in textual format. For example, 'Temp 3', 'Fan 6'." + ::= { swSensorEntry 5 } + + -- 23 is reserved + + swID OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of the logical switch (0/1)." + ::= { swSystem 24 } + + swEtherIPAddress OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The IP Address of the Ethernet interface of this logical + switch." + ::= { swSystem 25 } + + swEtherIPMask OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The IP Mask of the Ethernet interface of this logical switch." + ::= { swSystem 26} + + -- 27..28 are reserved + + swIPv6Address OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "IPV6 address." + ::= { swSystem 29 } + + swIPv6Status OBJECT-TYPE + SYNTAX INTEGER { + tentative (1), + preferred (2), + ipdeprecated (3), + inactive (4) + } + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "The current status of ipv6 address." + ::= { swSystem 30 } + + -- + -- End of System Group + -- + + -- + -- Fibre Channel Port Group + -- This group contains information about the physical state, + -- operational status, performance and error statistics of each + -- Fibre Channel port on the switch. A Fibre Channel port is one which + -- supports the Fibre Channel protocol. E.g. F_Port, E_Port, FL_Port. + -- + -- 1 reserved + + swFCPortTable OBJECT-TYPE + SYNTAX SEQUENCE OF SwFCPortEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "A table that contains, one entry for each switch port, + configuration and service parameters of the port." + ::= { swFCport 2 } + + swFCPortEntry OBJECT-TYPE + SYNTAX SwFCPortEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "An entry containing the configuration and service + parameters of the switch port." + INDEX { swFCPortIndex } + ::= { swFCPortTable 1 } + + SwFCPortEntry ::= SEQUENCE { + swFCPortIndex SwPortIndex, + swFCPortType INTEGER, + swFCPortPhyState INTEGER, + swFCPortOpStatus INTEGER, + swFCPortAdmStatus INTEGER, + + swFCPortLinkState INTEGER, + swFCPortTxType INTEGER, + + -- the rest is mapped to gstat_t + swFCPortTxWords Counter32, + swFCPortRxWords Counter32, + swFCPortTxFrames Counter32, + swFCPortRxFrames Counter32, + swFCPortRxC2Frames Counter32, + swFCPortRxC3Frames Counter32, + swFCPortRxLCs Counter32, + swFCPortRxMcasts Counter32, + swFCPortTooManyRdys Counter32, + swFCPortNoTxCredits Counter32, + swFCPortRxEncInFrs Counter32, + swFCPortRxCrcs Counter32, + swFCPortRxTruncs Counter32, + swFCPortRxTooLongs Counter32, + swFCPortRxBadEofs Counter32, + swFCPortRxEncOutFrs Counter32, + swFCPortRxBadOs Counter32, + swFCPortC3Discards Counter32, + swFCPortMcastTimedOuts Counter32, + swFCPortTxMcasts Counter32, + + -- LIP statistics + swFCPortLipIns Counter32, + swFCPortLipOuts Counter32, + swFCPortLipLastAlpa OCTET STRING, + + -- new for V2.1 + swFCPortWwn OCTET STRING, + + -- new for V3.0 + swFCPortSpeed INTEGER, + + -- new for Port Name Feature. + swFCPortName DisplayString, + + -- new for PortSpecifier Feature. + swFCPortSpecifier DisplayString, + + -- new for portFlag Feature. + swFCPortFlag FcPortFlag, + + -- Brocade port type. + swFCPortBrcdType INTEGER + } + + swFCPortIndex OBJECT-TYPE + SYNTAX SwPortIndex + MAX-ACCESS read-only + STATUS current + DESCRIPTION "This object identifies the switch port index. + Note that the value of a port index is 1 higher than the + port number labeled on the front panel. + E.g. port index 1 correspond to port number 0." + ::= { swFCPortEntry 1 } + + swFCPortType OBJECT-TYPE + SYNTAX INTEGER { + stitch (1), + flannel (2), + loom (3), + bloom (4), + rdbloom (5), + wormhole (6), + other (7), + unknown (8) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION "This object identifies the type of switch port. + It may be of type stitch(1), flannel(2), loom(3) , bloom(4),rdbloom(5) or wormhole(6)." + ::= { swFCPortEntry 2 } + + swFCPortPhyState OBJECT-TYPE + SYNTAX INTEGER { + noCard (1), + noTransceiver (2), + laserFault (3), + noLight (4), + noSync (5), + inSync (6), + portFault (7), + diagFault (8), + lockRef (9), + validating (10), + invalidModule (11), + unknown (255) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION "This object identifies the physical state of + the port: + noCard(1) no card present in this switch slot; + noTransceiver(2) no Transceiver module in this port. + noGbic(2) was used previously. Transceiver + is the generic name for GBIC, SFP etc.; + laserFault(3) the module is signaling a laser fault + (defective Transceiver); + noLight(4) the module is not receiving light; + noSync(5) the module is receiving light but is + out of sync; + inSync(6) the module is receiving light and is + in sync; + portFault(7) the port is marked faulty (defective + Transceiver, cable or device); + diagFault(8) the port failed diagnostics (defective + G_Port or FL_Port card or motherboard); + lockRef(9) the port is locking to the reference + signal. + validating(10) Validation is in progress + invalidModule(11) Invalid SFP + unknown(255) unknown. + " + ::= { swFCPortEntry 3 } + + swFCPortOpStatus OBJECT-TYPE + SYNTAX INTEGER { + unknown (0), + online (1), + offline (2), + testing (3), + faulty (4) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION "This object identifies the operational status of + the port. The online(1) state indicates that user frames + can be passed. The unknown(0) state indicates that likely + the port module is physically absent (see swFCPortPhyState)." + ::= { swFCPortEntry 4 } + + swFCPortAdmStatus OBJECT-TYPE + SYNTAX INTEGER { + online (1), + offline (2), + testing (3), + faulty (4) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION "The desired state of the port. A management station + may place the port in a desired state by setting this + object accordingly. The testing(3) state indicates that + no user frames can be passed. As the result of + either explicit management action or per configuration + information accessible by the switch, swFCPortAdmStatus is + then changed to either the online(1) or testing(3) + states, or remains in the offline(2) state." + ::= { swFCPortEntry 5 } + + swFCPortLinkState OBJECT-TYPE + SYNTAX INTEGER { + enabled (1), + disabled (2), + loopback (3) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION "This object indicates the link state of the port. + The value may be: + enabled(1) - port is allowed to participate in the FC-PH + protocol with its attached port (or ports if it is + in a FC-AL loop); + disabled(2) - the port is not allowed to participate in + the FC-PH protocol with its attached port(s); + loopback(3) - the port may transmit frames through an + internal path to verify the health of the transmitter + and receiver path. + + Note that when the port's link state changes, its + operational status (swFCPortOpStatus) will be affected." + ::= { swFCPortEntry 6 } + + swFCPortTxType OBJECT-TYPE + SYNTAX INTEGER { + unknown (1), + lw (2), + sw (3), + ld (4), + cu (5) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION "This object indicates the media transmitter type of + the port. The value may be: + unknown(1) cannot determined to the port driver + lw(2) long wave laser + sw(3) short wave laser + ld(4) long wave LED + cu(5) copper (electrical)." + ::= { swFCPortEntry 7 } + + -- counters + swFCPortTxWords OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "This object counts the number of Fibre Channel + words that the port has transmitted." + ::= { swFCPortEntry 11 } + + swFCPortRxWords OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "This object counts the number of Fibre Channel + words that the port has received." + ::= { swFCPortEntry 12 } + + swFCPortTxFrames OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "This object counts the number of (Fibre Channel) + frames that the port has transmitted." + ::= { swFCPortEntry 13 } + + swFCPortRxFrames OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "This object counts the number of (Fibre Channel) + frames that the port has received." + ::= { swFCPortEntry 14 } + + swFCPortRxC2Frames OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "This object counts the number of Class 2 + frames that the port has received." + ::= { swFCPortEntry 15 } + + swFCPortRxC3Frames OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "This object counts the number of Class 3 + frames that the port has received." + ::= { swFCPortEntry 16 } + + swFCPortRxLCs OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "This object counts the number of Link Control + frames that the port has received." + ::= { swFCPortEntry 17 } + + swFCPortRxMcasts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "This object counts the number of Multicast + frames that the port has received." + ::= { swFCPortEntry 18 } + + swFCPortTooManyRdys OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "This object counts the number of times when RDYs + exceeds the frames received." + ::= { swFCPortEntry 19 } + + swFCPortNoTxCredits OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "This object counts the number of times when the + transmit credit has reached zero." + ::= { swFCPortEntry 20 } + + swFCPortRxEncInFrs OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "This object counts the number of encoding error or + disparity error inside frames received." + ::= { swFCPortEntry 21 } + + swFCPortRxCrcs OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "This object counts the number of CRC errors + detected for frames received." + ::= { swFCPortEntry 22 } + + swFCPortRxTruncs OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "This object counts the number of truncated + frames that the port has received." + ::= { swFCPortEntry 23 } + + swFCPortRxTooLongs OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "This object counts the number of received frames that + are too long." + ::= { swFCPortEntry 24 } + + swFCPortRxBadEofs OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "This object counts the number of received frames that + have bad EOF delimiter." + ::= { swFCPortEntry 25 } + + swFCPortRxEncOutFrs OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "This object counts the number of encoding error or + disparity error outside frames received." + ::= { swFCPortEntry 26 } + + swFCPortRxBadOs OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "This object counts the number of invalid Ordered + Sets received." + ::= { swFCPortEntry 27 } + + swFCPortC3Discards OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "This object counts the number of Class 3 + frames that the port has discarded." + ::= { swFCPortEntry 28 } + + swFCPortMcastTimedOuts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "This object counts the number of Multicast + frames that has been timed out." + ::= { swFCPortEntry 29 } + + swFCPortTxMcasts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "This object counts the number of Multicast + frames that has been transmitted." + ::= { swFCPortEntry 30 } + + -- LIP statistics + swFCPortLipIns OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "This object counts the number of Loop Initializations + that has been initiated by loop devices attached." + ::= { swFCPortEntry 31 } + + swFCPortLipOuts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "This object counts the number of Loop Initializations + that has been initiated by the port." + ::= { swFCPortEntry 32 } + + swFCPortLipLastAlpa OBJECT-TYPE + SYNTAX OCTET STRING (SIZE(4)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "This object indicates the Physical Address (AL_PA) + of the loop device that initiated the last + Loop Initialization." + ::= { swFCPortEntry 33 } + + swFCPortWwn OBJECT-TYPE + SYNTAX OCTET STRING (SIZE(8)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The World_wide_Name of the Fibre Channel port. + The contents of an instance are in the IEEE extended format + as specified in FC-PH; the 12-bit port identifier represents + the port number within the switch." + ::= { swFCPortEntry 34 } + + swFCPortSpeed OBJECT-TYPE + SYNTAX INTEGER + { + one-GB (1), + two-GB (2), + auto-Negotiate (3), + four-GB (4), + eight-GB (5), + ten-GB (6), + unknown (7) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION "The desired baud rate for the port. It can have the + values of 1GB (1), 2GB (2), Auto-Negotiate (3), 4GB (4), 8GB (5), + or 10GB (6). Some of the above values may not be supported + by all type of switches." + ::= { swFCPortEntry 35 } + + swFCPortName OBJECT-TYPE + SYNTAX DisplayString(SIZE(0..255)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "A string indicates the name of the addressed port. + The names should be persistent across switch reboots. + Port names do not have to be unique within a switch or + within a fabric." + ::= { swFCPortEntry 36 } + + swFCPortSpecifier OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "This string indicates the physical port number of the addressed port. + The format of the string is: <slot>/port, where 'slot' being + present only for bladed systems. + " + ::= { swFCPortEntry 37 } + + -- FC port status flag + + swFCPortFlag OBJECT-TYPE + SYNTAX FcPortFlag + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A bit map of port status flags which includes the information of port type. + Currently this will indicate if the port is virtual or physical." + ::= { swFCPortEntry 38 } + + swFCPortBrcdType OBJECT-TYPE + SYNTAX INTEGER { + unknown (1), + other (2), + fl-port (3), -- public loop + f-port (4), -- fabric port + e-port (5), -- fabric expansion port + g-port (6), -- generic fabric port + ex-port (7) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The Brocade port type." + ::= { swFCPortEntry 39 } + + + -- + -- End of Fibre Channel Port group + -- + + -- + -- swEventTable is defined to gather event info for trap + -- SNMP GET/SET is not supported on this + -- + + -- possible events available, included her for lib/thresh/fwd.c compilation + SwFwEvent ::= INTEGER { + started(1), + changed(2), + exceeded(3), + below(4), + above(5), + inBetween(6), + lowBufferCrsd(7) + } + + + swEventTable OBJECT-TYPE + SYNTAX SEQUENCE OF SwEventEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "The table of event entries." + ::= { swEvent 5 } + + swEventEntry OBJECT-TYPE + SYNTAX SwEventEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "An entry of the event table." + INDEX { swEventIndex } + + ::= { swEventTable 1 } + + SwEventEntry ::= SEQUENCE { + swEventIndex Integer32, + swEventTimeInfo DisplayString, + swEventLevel INTEGER, + swEventRepeatCount Integer32, + swEventDescr DisplayString, + swEventVfId Integer32 + } + + swEventIndex OBJECT-TYPE + SYNTAX Integer32 (0..2147483647) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "This object identifies the event entry." + ::= { swEventEntry 1 } + + swEventTimeInfo OBJECT-TYPE + SYNTAX DisplayString(SIZE (0..64)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "This object identifies the date and time when this + event occurred, in textual format." + ::= { swEventEntry 2 } + + swEventLevel OBJECT-TYPE + SYNTAX INTEGER { + critical (1), + error (2), + warning (3), + informational (4), + debug (5) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION "This object identifies the severity level of this + event entry." + ::= { swEventEntry 3 } + + swEventRepeatCount OBJECT-TYPE + SYNTAX Integer32 (0..2147483647) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "This object identifies how many times this particular + event has occurred." + ::= { swEventEntry 4 } + + swEventDescr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "This object identifies the textual description of + the event." + ::= { swEventEntry 5 } + + swEventVfId OBJECT-TYPE + SYNTAX Integer32 (0..255) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "This object identifies the Virtual fabric id." + ::= { swEventEntry 6 } + + +-- +-- Enterprise Specific Traps for Switch (sw). +-- + + swTrapsV2 OBJECT-IDENTITY + STATUS current + DESCRIPTION "The Traps for Brocade's Switch." + ::= { sw 0 } + + swFCPortScn NOTIFICATION-TYPE + OBJECTS { swFCPortOpStatus, swFCPortIndex, swFCPortName, + swSsn, swFCPortFlag, swVfId } + STATUS current + DESCRIPTION "This trap is sent whenever an FC port operational status or + its type changed. The events that trigger this trap are + port goes to online/offline, port type changed to + E-port/F-port/FL-port. swFCPortName and swSsn are optional + varbind in the trap PDU.swSsn is optional varbind sent when swExtTrap + is also enabled.swVfId is optional if VF is enabled." + --#TYPE "A Fibre Channel Port changed its operational state." + --#SUMMARY "Port Index %d changed state to %d Port Name: %s and SSN is #%s" + --#ARGUMENTS { 1, 0, 2, 3 } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#STATE OPERATIONAL + ::= { swTrapsV2 3 } + + swEventTrap NOTIFICATION-TYPE + OBJECTS { swEventIndex, swEventTimeInfo, swEventLevel, + swEventRepeatCount, swEventDescr, swSsn, swVfId } + STATUS current + DESCRIPTION "This trap is generated when an event whose + level at or below swEventTrapLevel occurs." + --#TYPE "A firmware event has been logged" + --#SUMMARY "Event %d: %s (severity level %d) - %s SSN is #%s" + --#ARGUMENTS { 0, 1, 2, 4, 5 } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#STATE OPERATIONAL + ::= { swTrapsV2 4 } + + swStateChangeTrap NOTIFICATION-TYPE + OBJECTS { swOperStatus, swVfId} + STATUS current + DESCRIPTION "This trap is sent whenever switch state changes to online/offline" + ::= { swTrapsV2 12 } + +END |