summaryrefslogtreecommitdiff
path: root/MIBS/cisco/CISCO-UNIFIED-COMPUTING-COMPUTE-MIB
diff options
context:
space:
mode:
authorDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
committerDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
commit98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch)
tree9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/cisco/CISCO-UNIFIED-COMPUTING-COMPUTE-MIB
downloadmibs-main.tar.gz
mibs-main.zip
Initial commitHEADmain
Diffstat (limited to 'MIBS/cisco/CISCO-UNIFIED-COMPUTING-COMPUTE-MIB')
-rw-r--r--MIBS/cisco/CISCO-UNIFIED-COMPUTING-COMPUTE-MIB12616
1 files changed, 12616 insertions, 0 deletions
diff --git a/MIBS/cisco/CISCO-UNIFIED-COMPUTING-COMPUTE-MIB b/MIBS/cisco/CISCO-UNIFIED-COMPUTING-COMPUTE-MIB
new file mode 100644
index 0000000..4551401
--- /dev/null
+++ b/MIBS/cisco/CISCO-UNIFIED-COMPUTING-COMPUTE-MIB
@@ -0,0 +1,12616 @@
+-- *********************************************************************
+-- CISCO-UNIFIED-COMPUTING-COMPUTE-MIB.my
+--
+-- MIB representation of the Cisco Unified Computing System
+-- COMPUTE management information model package
+--
+-- Created January 2016 by Charles Bullis
+--
+-- Copyright (c) 2005-2016 Cisco Systems, Inc. All rights reserved.
+--
+-- *********************************************************************
+
+CISCO-UNIFIED-COMPUTING-COMPUTE-MIB DEFINITIONS ::= BEGIN
+
+IMPORTS
+ MODULE-IDENTITY,
+ OBJECT-TYPE,
+ Counter32,
+ Gauge32,
+ TimeTicks,
+ Counter64,
+ Unsigned32
+ FROM SNMPv2-SMI
+ TEXTUAL-CONVENTION,
+ RowPointer,
+ DateAndTime,
+ DisplayString,
+ MacAddress,
+ TimeInterval,
+ TimeStamp,
+ TruthValue
+ FROM SNMPv2-TC
+ SnmpAdminString
+ FROM SNMP-FRAMEWORK-MIB
+ InetAddressIPv4,
+ InetAddressIPv6
+ FROM INET-ADDRESS-MIB
+ ciscoMgmt
+ FROM CISCO-SMI
+ CiscoNetworkAddress,
+ Unsigned64,
+ CiscoInetAddressMask,
+ CiscoAlarmSeverity,
+ TimeIntervalSec
+ FROM CISCO-TC
+ ciscoUnifiedComputingMIBObjects,
+ CucsManagedObjectId,
+ CucsManagedObjectDn
+ FROM CISCO-UNIFIED-COMPUTING-MIB
+ CucsComputeABoardPower,
+ CucsComputeAdminLinkAggregation,
+ CucsComputeAdminMemoryState,
+ CucsComputeAdminPowerState,
+ CucsComputeAdminState,
+ CucsComputeAdminTrigger,
+ CucsComputeAlarmSeverity,
+ CucsComputeAssociation,
+ CucsComputeAvailability,
+ CucsComputeBlackListing,
+ CucsComputeBladeEpId,
+ CucsComputeBladeEpSlotId,
+ CucsComputeBladeFsmCurrentFsm,
+ CucsComputeBladeFsmStageName,
+ CucsComputeBladeFsmTaskFlags,
+ CucsComputeBladeFsmTaskItem,
+ CucsComputeBladeSlotId,
+ CucsComputeCartridgeDiscovery,
+ CucsComputeCartridgeSlotId,
+ CucsComputeChassisConnPolicyChassisId,
+ CucsComputeChassisDiscAction,
+ CucsComputeChassisDiscPolicyMulticastHwHash,
+ CucsComputeChassisQualMaxId,
+ CucsComputeChassisQualMinId,
+ CucsComputeCheckPoint,
+ CucsComputeConnectivityRebalancing,
+ CucsComputeDiscovery,
+ CucsComputeEquipmentConstraintType,
+ CucsComputeIOHubEnvStatsHistThresholded,
+ CucsComputeIOHubEnvStatsThresholded,
+ CucsComputeInstanceIdQualMaxId,
+ CucsComputeInstanceIdQualMinId,
+ CucsComputeIssues,
+ CucsComputeKvmMgmtPolicyVmediaEncryption,
+ CucsComputeLinkAggregation,
+ CucsComputeMbPowerStatsHistThresholded,
+ CucsComputeMbPowerStatsThresholded,
+ CucsComputeMbTempStatsHistThresholded,
+ CucsComputeMbTempStatsThresholded,
+ CucsComputeMemoryUnitConstraintType,
+ CucsComputeMode,
+ CucsComputeOwner,
+ CucsComputePCIeFatalCompletionStatsThresholded,
+ CucsComputePCIeFatalProtocolStatsThresholded,
+ CucsComputePCIeFatalReceiveStatsThresholded,
+ CucsComputePCIeFatalStatsThresholded,
+ CucsComputePciCapOrder,
+ CucsComputePhysicalFsmCurrentFsm,
+ CucsComputePhysicalFsmStageName,
+ CucsComputePhysicalFsmTaskFlags,
+ CucsComputePhysicalFsmTaskItem,
+ CucsComputePhysicalLowVoltageMemory,
+ CucsComputePooledEnclosureComputeSlotServerInstanceId,
+ CucsComputePooledEnclosureComputeSlotSlotId,
+ CucsComputePooledRackUnitId,
+ CucsComputePooledSlotSlotId,
+ CucsComputePowerTransitionSrc,
+ CucsComputePsuClusterState,
+ CucsComputePsuControlRedundancy,
+ CucsComputePsuRedundancy,
+ CucsComputePsuRedundancyOperQualifier,
+ CucsComputePsuRedundancyOperState,
+ CucsComputeRackQualMaxId,
+ CucsComputeRackQualMinId,
+ CucsComputeRackUnitFsmCurrentFsm,
+ CucsComputeRackUnitFsmStageName,
+ CucsComputeRackUnitFsmTaskFlags,
+ CucsComputeRackUnitFsmTaskItem,
+ CucsComputeRackUnitId,
+ CucsComputeRackUnitMbTempStatsHistThresholded,
+ CucsComputeRackUnitMbTempStatsThresholded,
+ CucsComputeScrubAction,
+ CucsComputeServerDiscPolicyFsmCurrentFsm,
+ CucsComputeServerDiscPolicyFsmStageName,
+ CucsComputeServerDiscPolicyFsmTaskItem,
+ CucsComputeServerMgmtDiscAction,
+ CucsComputeServerTypeCapType,
+ CucsComputeServerUnitChassisId,
+ CucsComputeServerUnitFsmCurrentFsm,
+ CucsComputeServerUnitFsmStageName,
+ CucsComputeServerUnitFsmTaskFlags,
+ CucsComputeServerUnitFsmTaskItem,
+ CucsComputeServerUnitServerInstanceId,
+ CucsComputeServerUnitSlotId,
+ CucsComputeSlotQualMaxId,
+ CucsComputeSlotQualMinId,
+ CucsComputeUpgradeStatus,
+ CucsConditionRemoteInvRslt,
+ CucsEquipmentBoardAggregationRole,
+ CucsEquipmentBoardConnectorType,
+ CucsEquipmentConnectionStatus,
+ CucsEquipmentFanSpeedPolicyFault,
+ CucsEquipmentOperability,
+ CucsEquipmentPowerState,
+ CucsEquipmentPresence,
+ CucsEquipmentSensorThresholdStatus,
+ CucsEquipmentSlotStatus,
+ CucsFsmCompletion,
+ CucsFsmFlags,
+ CucsFsmFsmStageStatus,
+ CucsLsOperState,
+ CucsNetworkSwitchId,
+ CucsPolicyPolicyOwner,
+ CucsPoolPoolAssignmentOrder,
+ CucsTrigAckChangeDetails,
+ CucsTrigAckChanges,
+ CucsTrigAckDisr,
+ CucsTrigAckOperState,
+ CucsTrigAckPrevOperState,
+ CucsTrigAdminState,
+ CucsTrigTrigState
+ FROM CISCO-UNIFIED-COMPUTING-TC-MIB;
+
+cucsComputeObjects MODULE-IDENTITY
+ LAST-UPDATED "201601180000Z"
+ ORGANIZATION "Cisco Systems Inc."
+ CONTACT-INFO
+ "Cisco Systems
+ Customer Service
+
+ Postal: 170 W Tasman Drive
+ San Jose, CA 95134
+ USA
+
+ Tel: +1 800 553 -NETS
+
+ E-mail: cs-san@cisco.com, cs-lan-switch-snmp@cisco.com"
+ DESCRIPTION
+ "MIB representation of the Cisco Unified Computing System
+ COMPUTE management information model package"
+ ::= { ciscoUnifiedComputingMIBObjects 9 }
+
+cucsComputeAutoconfigPolicyTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputeAutoconfigPolicyEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:AutoconfigPolicy managed object table"
+ ::= { cucsComputeObjects 1 }
+
+cucsComputeAutoconfigPolicyEntry OBJECT-TYPE
+ SYNTAX CucsComputeAutoconfigPolicyEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputeAutoconfigPolicyTable table."
+ INDEX { cucsComputeAutoconfigPolicyInstanceId }
+ ::= { cucsComputeAutoconfigPolicyTable 1 }
+
+CucsComputeAutoconfigPolicyEntry ::= SEQUENCE {
+ cucsComputeAutoconfigPolicyInstanceId CucsManagedObjectId,
+ cucsComputeAutoconfigPolicyDn CucsManagedObjectDn,
+ cucsComputeAutoconfigPolicyRn SnmpAdminString,
+ cucsComputeAutoconfigPolicyDescr SnmpAdminString,
+ cucsComputeAutoconfigPolicyDstDn SnmpAdminString,
+ cucsComputeAutoconfigPolicyIntId SnmpAdminString,
+ cucsComputeAutoconfigPolicyName SnmpAdminString,
+ cucsComputeAutoconfigPolicyQualifier SnmpAdminString,
+ cucsComputeAutoconfigPolicySrcTemplName SnmpAdminString,
+ cucsComputeAutoconfigPolicyPolicyLevel Gauge32,
+ cucsComputeAutoconfigPolicyPolicyOwner CucsPolicyPolicyOwner,
+ cucsComputeAutoconfigPolicyOperQualifier SnmpAdminString
+}
+
+cucsComputeAutoconfigPolicyInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputeAutoconfigPolicyEntry 1 }
+
+cucsComputeAutoconfigPolicyDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:AutoconfigPolicy:dn managed object property"
+ ::= { cucsComputeAutoconfigPolicyEntry 2 }
+
+cucsComputeAutoconfigPolicyRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:AutoconfigPolicy:rn managed object property"
+ ::= { cucsComputeAutoconfigPolicyEntry 3 }
+
+cucsComputeAutoconfigPolicyDescr OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:AutoconfigPolicy:descr managed object property"
+ ::= { cucsComputeAutoconfigPolicyEntry 4 }
+
+cucsComputeAutoconfigPolicyDstDn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:AutoconfigPolicy:dstDn managed object property"
+ ::= { cucsComputeAutoconfigPolicyEntry 5 }
+
+cucsComputeAutoconfigPolicyIntId OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:AutoconfigPolicy:intId managed object property"
+ ::= { cucsComputeAutoconfigPolicyEntry 6 }
+
+cucsComputeAutoconfigPolicyName OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:AutoconfigPolicy:name managed object property"
+ ::= { cucsComputeAutoconfigPolicyEntry 7 }
+
+cucsComputeAutoconfigPolicyQualifier OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:AutoconfigPolicy:qualifier managed
+ object property"
+ ::= { cucsComputeAutoconfigPolicyEntry 8 }
+
+cucsComputeAutoconfigPolicySrcTemplName OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:AutoconfigPolicy:srcTemplName
+ managed object property"
+ ::= { cucsComputeAutoconfigPolicyEntry 9 }
+
+cucsComputeAutoconfigPolicyPolicyLevel OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:AutoconfigPolicy:policyLevel
+ managed object property"
+ ::= { cucsComputeAutoconfigPolicyEntry 10 }
+
+cucsComputeAutoconfigPolicyPolicyOwner OBJECT-TYPE
+ SYNTAX CucsPolicyPolicyOwner
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:AutoconfigPolicy:policyOwner
+ managed object property"
+ ::= { cucsComputeAutoconfigPolicyEntry 11 }
+
+cucsComputeAutoconfigPolicyOperQualifier OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:AutoconfigPolicy:operQualifier
+ managed object property"
+ ::= { cucsComputeAutoconfigPolicyEntry 12 }
+
+cucsComputeBladeTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputeBladeEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Blade managed object table"
+ ::= { cucsComputeObjects 2 }
+
+cucsComputeBladeEntry OBJECT-TYPE
+ SYNTAX CucsComputeBladeEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputeBladeTable table."
+ INDEX { cucsComputeBladeInstanceId }
+ ::= { cucsComputeBladeTable 1 }
+
+CucsComputeBladeEntry ::= SEQUENCE {
+ cucsComputeBladeInstanceId CucsManagedObjectId,
+ cucsComputeBladeDn CucsManagedObjectDn,
+ cucsComputeBladeRn SnmpAdminString,
+ cucsComputeBladeAdminPower CucsComputeAdminPowerState,
+ cucsComputeBladeAdminState CucsComputeAdminState,
+ cucsComputeBladeAssignedToDn SnmpAdminString,
+ cucsComputeBladeAssociation CucsComputeAssociation,
+ cucsComputeBladeAvailability CucsComputeAvailability,
+ cucsComputeBladeAvailableMemory Gauge32,
+ cucsComputeBladeChassisId Gauge32,
+ cucsComputeBladeCheckPoint CucsComputeCheckPoint,
+ cucsComputeBladeConnPath CucsEquipmentConnectionStatus,
+ cucsComputeBladeConnStatus CucsEquipmentConnectionStatus,
+ cucsComputeBladeDescr SnmpAdminString,
+ cucsComputeBladeDiscovery CucsComputeDiscovery,
+ cucsComputeBladeFltAggr Unsigned64,
+ cucsComputeBladeFsmDescr SnmpAdminString,
+ cucsComputeBladeFsmFlags SnmpAdminString,
+ cucsComputeBladeFsmPrev SnmpAdminString,
+ cucsComputeBladeFsmProgr Gauge32,
+ cucsComputeBladeFsmRmtInvErrCode Gauge32,
+ cucsComputeBladeFsmRmtInvErrDescr SnmpAdminString,
+ cucsComputeBladeFsmRmtInvRslt CucsConditionRemoteInvRslt,
+ cucsComputeBladeFsmStageDescr SnmpAdminString,
+ cucsComputeBladeFsmStamp DateAndTime,
+ cucsComputeBladeFsmStatus SnmpAdminString,
+ cucsComputeBladeFsmTry Gauge32,
+ cucsComputeBladeIntId SnmpAdminString,
+ cucsComputeBladeLc CucsComputeAdminTrigger,
+ cucsComputeBladeLcTs DateAndTime,
+ cucsComputeBladeManagingInst CucsNetworkSwitchId,
+ cucsComputeBladeModel SnmpAdminString,
+ cucsComputeBladeName SnmpAdminString,
+ cucsComputeBladeNumOfAdaptors Gauge32,
+ cucsComputeBladeNumOfCores Gauge32,
+ cucsComputeBladeNumOfCpus Gauge32,
+ cucsComputeBladeNumOfEthHostIfs Gauge32,
+ cucsComputeBladeNumOfFcHostIfs Gauge32,
+ cucsComputeBladeNumOfThreads Gauge32,
+ cucsComputeBladeOperPower CucsEquipmentPowerState,
+ cucsComputeBladeOperQualifier CucsComputeIssues,
+ cucsComputeBladeOperState CucsLsOperState,
+ cucsComputeBladeOperability CucsEquipmentOperability,
+ cucsComputeBladeOriginalUuid SnmpAdminString,
+ cucsComputeBladePresence CucsEquipmentSlotStatus,
+ cucsComputeBladeRevision SnmpAdminString,
+ cucsComputeBladeSerial SnmpAdminString,
+ cucsComputeBladeServerId SnmpAdminString,
+ cucsComputeBladeSlotId CucsComputeBladeSlotId,
+ cucsComputeBladeTotalMemory Gauge32,
+ cucsComputeBladeUsrLbl SnmpAdminString,
+ cucsComputeBladeUuid SnmpAdminString,
+ cucsComputeBladeVendor SnmpAdminString,
+ cucsComputeBladeNumOfCoresEnabled Gauge32,
+ cucsComputeBladeLowVoltageMemory CucsComputePhysicalLowVoltageMemory,
+ cucsComputeBladeMemorySpeed Gauge32,
+ cucsComputeBladeMfgTime DateAndTime,
+ cucsComputeBladePartNumber SnmpAdminString,
+ cucsComputeBladeVid SnmpAdminString,
+ cucsComputeBladePolicyLevel Gauge32,
+ cucsComputeBladePolicyOwner CucsPolicyPolicyOwner,
+ cucsComputeBladeLocalId SnmpAdminString,
+ cucsComputeBladeScaledMode CucsComputeMode,
+ cucsComputeBladeUpgradeScenario CucsComputeUpgradeStatus,
+ cucsComputeBladeOperPwrTransSrc CucsComputePowerTransitionSrc,
+ cucsComputeBladeDiscoveryStatus CucsEquipmentConnectionStatus,
+ cucsComputeBladeNumOf40GAdaptorsWithOldFw Gauge32,
+ cucsComputeBladeNumOf40GAdaptorsWithUnknownFw Gauge32
+}
+
+cucsComputeBladeInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputeBladeEntry 1 }
+
+cucsComputeBladeDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Blade:dn managed object property"
+ ::= { cucsComputeBladeEntry 2 }
+
+cucsComputeBladeRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Blade:rn managed object property"
+ ::= { cucsComputeBladeEntry 3 }
+
+cucsComputeBladeAdminPower OBJECT-TYPE
+ SYNTAX CucsComputeAdminPowerState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Blade:adminPower managed object property"
+ ::= { cucsComputeBladeEntry 4 }
+
+cucsComputeBladeAdminState OBJECT-TYPE
+ SYNTAX CucsComputeAdminState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Blade:adminState managed object property"
+ ::= { cucsComputeBladeEntry 5 }
+
+cucsComputeBladeAssignedToDn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Blade:assignedToDn managed object property"
+ ::= { cucsComputeBladeEntry 6 }
+
+cucsComputeBladeAssociation OBJECT-TYPE
+ SYNTAX CucsComputeAssociation
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Blade:association managed object property"
+ ::= { cucsComputeBladeEntry 7 }
+
+cucsComputeBladeAvailability OBJECT-TYPE
+ SYNTAX CucsComputeAvailability
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Blade:availability managed object property"
+ ::= { cucsComputeBladeEntry 8 }
+
+cucsComputeBladeAvailableMemory OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Blade:availableMemory managed object property"
+ ::= { cucsComputeBladeEntry 9 }
+
+cucsComputeBladeChassisId OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Blade:chassisId managed object property"
+ ::= { cucsComputeBladeEntry 10 }
+
+cucsComputeBladeCheckPoint OBJECT-TYPE
+ SYNTAX CucsComputeCheckPoint
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Blade:checkPoint managed object property"
+ ::= { cucsComputeBladeEntry 11 }
+
+cucsComputeBladeConnPath OBJECT-TYPE
+ SYNTAX CucsEquipmentConnectionStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Blade:connPath managed object property"
+ ::= { cucsComputeBladeEntry 12 }
+
+cucsComputeBladeConnStatus OBJECT-TYPE
+ SYNTAX CucsEquipmentConnectionStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Blade:connStatus managed object property"
+ ::= { cucsComputeBladeEntry 13 }
+
+cucsComputeBladeDescr OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Blade:descr managed object property"
+ ::= { cucsComputeBladeEntry 14 }
+
+cucsComputeBladeDiscovery OBJECT-TYPE
+ SYNTAX CucsComputeDiscovery
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Blade:discovery managed object property"
+ ::= { cucsComputeBladeEntry 15 }
+
+cucsComputeBladeFltAggr OBJECT-TYPE
+ SYNTAX Unsigned64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Blade:fltAggr managed object property"
+ ::= { cucsComputeBladeEntry 16 }
+
+cucsComputeBladeFsmDescr OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Blade:fsmDescr managed object property"
+ ::= { cucsComputeBladeEntry 17 }
+
+cucsComputeBladeFsmFlags OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Blade:fsmFlags managed object property"
+ ::= { cucsComputeBladeEntry 18 }
+
+cucsComputeBladeFsmPrev OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Blade:fsmPrev managed object property"
+ ::= { cucsComputeBladeEntry 19 }
+
+cucsComputeBladeFsmProgr OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Blade:fsmProgr managed object property"
+ ::= { cucsComputeBladeEntry 20 }
+
+cucsComputeBladeFsmRmtInvErrCode OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Blade:fsmRmtInvErrCode managed object property"
+ ::= { cucsComputeBladeEntry 21 }
+
+cucsComputeBladeFsmRmtInvErrDescr OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Blade:fsmRmtInvErrDescr managed
+ object property"
+ ::= { cucsComputeBladeEntry 22 }
+
+cucsComputeBladeFsmRmtInvRslt OBJECT-TYPE
+ SYNTAX CucsConditionRemoteInvRslt
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Blade:fsmRmtInvRslt managed object property"
+ ::= { cucsComputeBladeEntry 23 }
+
+cucsComputeBladeFsmStageDescr OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Blade:fsmStageDescr managed object property"
+ ::= { cucsComputeBladeEntry 24 }
+
+cucsComputeBladeFsmStamp OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Blade:fsmStamp managed object property"
+ ::= { cucsComputeBladeEntry 25 }
+
+cucsComputeBladeFsmStatus OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Blade:fsmStatus managed object property"
+ ::= { cucsComputeBladeEntry 26 }
+
+cucsComputeBladeFsmTry OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Blade:fsmTry managed object property"
+ ::= { cucsComputeBladeEntry 27 }
+
+cucsComputeBladeIntId OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Blade:intId managed object property"
+ ::= { cucsComputeBladeEntry 28 }
+
+cucsComputeBladeLc OBJECT-TYPE
+ SYNTAX CucsComputeAdminTrigger
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Blade:lc managed object property"
+ ::= { cucsComputeBladeEntry 29 }
+
+cucsComputeBladeLcTs OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Blade:lcTs managed object property"
+ ::= { cucsComputeBladeEntry 30 }
+
+cucsComputeBladeManagingInst OBJECT-TYPE
+ SYNTAX CucsNetworkSwitchId
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Blade:managingInst managed object property"
+ ::= { cucsComputeBladeEntry 31 }
+
+cucsComputeBladeModel OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Blade:model managed object property"
+ ::= { cucsComputeBladeEntry 32 }
+
+cucsComputeBladeName OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Blade:name managed object property"
+ ::= { cucsComputeBladeEntry 33 }
+
+cucsComputeBladeNumOfAdaptors OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Blade:numOfAdaptors managed object property"
+ ::= { cucsComputeBladeEntry 34 }
+
+cucsComputeBladeNumOfCores OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Blade:numOfCores managed object property"
+ ::= { cucsComputeBladeEntry 35 }
+
+cucsComputeBladeNumOfCpus OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Blade:numOfCpus managed object property"
+ ::= { cucsComputeBladeEntry 36 }
+
+cucsComputeBladeNumOfEthHostIfs OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Blade:numOfEthHostIfs managed object property"
+ ::= { cucsComputeBladeEntry 37 }
+
+cucsComputeBladeNumOfFcHostIfs OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Blade:numOfFcHostIfs managed object property"
+ ::= { cucsComputeBladeEntry 38 }
+
+cucsComputeBladeNumOfThreads OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Blade:numOfThreads managed object property"
+ ::= { cucsComputeBladeEntry 39 }
+
+cucsComputeBladeOperPower OBJECT-TYPE
+ SYNTAX CucsEquipmentPowerState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Blade:operPower managed object property"
+ ::= { cucsComputeBladeEntry 40 }
+
+cucsComputeBladeOperQualifier OBJECT-TYPE
+ SYNTAX CucsComputeIssues
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Blade:operQualifier managed object property"
+ ::= { cucsComputeBladeEntry 41 }
+
+cucsComputeBladeOperState OBJECT-TYPE
+ SYNTAX CucsLsOperState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Blade:operState managed object property"
+ ::= { cucsComputeBladeEntry 42 }
+
+cucsComputeBladeOperability OBJECT-TYPE
+ SYNTAX CucsEquipmentOperability
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Blade:operability managed object property"
+ ::= { cucsComputeBladeEntry 43 }
+
+cucsComputeBladeOriginalUuid OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Blade:originalUuid managed object property"
+ ::= { cucsComputeBladeEntry 44 }
+
+cucsComputeBladePresence OBJECT-TYPE
+ SYNTAX CucsEquipmentSlotStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Blade:presence managed object property"
+ ::= { cucsComputeBladeEntry 45 }
+
+cucsComputeBladeRevision OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Blade:revision managed object property"
+ ::= { cucsComputeBladeEntry 46 }
+
+cucsComputeBladeSerial OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Blade:serial managed object property"
+ ::= { cucsComputeBladeEntry 47 }
+
+cucsComputeBladeServerId OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Blade:serverId managed object property"
+ ::= { cucsComputeBladeEntry 48 }
+
+cucsComputeBladeSlotId OBJECT-TYPE
+ SYNTAX CucsComputeBladeSlotId
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Blade:slotId managed object property"
+ ::= { cucsComputeBladeEntry 49 }
+
+cucsComputeBladeTotalMemory OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Blade:totalMemory managed object property"
+ ::= { cucsComputeBladeEntry 50 }
+
+cucsComputeBladeUsrLbl OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Blade:usrLbl managed object property"
+ ::= { cucsComputeBladeEntry 51 }
+
+cucsComputeBladeUuid OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Blade:uuid managed object property"
+ ::= { cucsComputeBladeEntry 52 }
+
+cucsComputeBladeVendor OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Blade:vendor managed object property"
+ ::= { cucsComputeBladeEntry 53 }
+
+cucsComputeBladeNumOfCoresEnabled OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Blade:numOfCoresEnabled managed
+ object property"
+ ::= { cucsComputeBladeEntry 54 }
+
+cucsComputeBladeLowVoltageMemory OBJECT-TYPE
+ SYNTAX CucsComputePhysicalLowVoltageMemory
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Blade:lowVoltageMemory managed object property"
+ ::= { cucsComputeBladeEntry 55 }
+
+cucsComputeBladeMemorySpeed OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Blade:memorySpeed managed object property"
+ ::= { cucsComputeBladeEntry 56 }
+
+cucsComputeBladeMfgTime OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Blade:mfgTime managed object property"
+ ::= { cucsComputeBladeEntry 57 }
+
+cucsComputeBladePartNumber OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Blade:partNumber managed object property"
+ ::= { cucsComputeBladeEntry 58 }
+
+cucsComputeBladeVid OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Blade:vid managed object property"
+ ::= { cucsComputeBladeEntry 59 }
+
+cucsComputeBladePolicyLevel OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Blade:policyLevel managed object property"
+ ::= { cucsComputeBladeEntry 60 }
+
+cucsComputeBladePolicyOwner OBJECT-TYPE
+ SYNTAX CucsPolicyPolicyOwner
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Blade:policyOwner managed object property"
+ ::= { cucsComputeBladeEntry 61 }
+
+cucsComputeBladeLocalId OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Blade:localId managed object property"
+ ::= { cucsComputeBladeEntry 62 }
+
+cucsComputeBladeScaledMode OBJECT-TYPE
+ SYNTAX CucsComputeMode
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Blade:scaledMode managed object property"
+ ::= { cucsComputeBladeEntry 63 }
+
+cucsComputeBladeUpgradeScenario OBJECT-TYPE
+ SYNTAX CucsComputeUpgradeStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Blade:upgradeScenario managed object property"
+ ::= { cucsComputeBladeEntry 64 }
+
+cucsComputeBladeOperPwrTransSrc OBJECT-TYPE
+ SYNTAX CucsComputePowerTransitionSrc
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Blade:operPwrTransSrc managed object property"
+ ::= { cucsComputeBladeEntry 65 }
+
+cucsComputeBladeDiscoveryStatus OBJECT-TYPE
+ SYNTAX CucsEquipmentConnectionStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Blade:discoveryStatus managed object property"
+ ::= { cucsComputeBladeEntry 66 }
+
+cucsComputeBladeNumOf40GAdaptorsWithOldFw OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Blade:numOf40GAdaptorsWithOldFw
+ managed object property"
+ ::= { cucsComputeBladeEntry 68 }
+
+cucsComputeBladeNumOf40GAdaptorsWithUnknownFw OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Blade:numOf40GAdaptorsWithUnknownFw
+ managed object property"
+ ::= { cucsComputeBladeEntry 69 }
+
+cucsComputeBladeDiscPolicyTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputeBladeDiscPolicyEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BladeDiscPolicy managed object table"
+ ::= { cucsComputeObjects 3 }
+
+cucsComputeBladeDiscPolicyEntry OBJECT-TYPE
+ SYNTAX CucsComputeBladeDiscPolicyEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputeBladeDiscPolicyTable table."
+ INDEX { cucsComputeBladeDiscPolicyInstanceId }
+ ::= { cucsComputeBladeDiscPolicyTable 1 }
+
+CucsComputeBladeDiscPolicyEntry ::= SEQUENCE {
+ cucsComputeBladeDiscPolicyInstanceId CucsManagedObjectId,
+ cucsComputeBladeDiscPolicyDn CucsManagedObjectDn,
+ cucsComputeBladeDiscPolicyRn SnmpAdminString,
+ cucsComputeBladeDiscPolicyAction SnmpAdminString,
+ cucsComputeBladeDiscPolicyDescr SnmpAdminString,
+ cucsComputeBladeDiscPolicyIntId SnmpAdminString,
+ cucsComputeBladeDiscPolicyName SnmpAdminString,
+ cucsComputeBladeDiscPolicyQualifier SnmpAdminString,
+ cucsComputeBladeDiscPolicyScrubPolicyName SnmpAdminString,
+ cucsComputeBladeDiscPolicyPolicyLevel Gauge32,
+ cucsComputeBladeDiscPolicyPolicyOwner CucsPolicyPolicyOwner
+}
+
+cucsComputeBladeDiscPolicyInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputeBladeDiscPolicyEntry 1 }
+
+cucsComputeBladeDiscPolicyDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BladeDiscPolicy:dn managed object property"
+ ::= { cucsComputeBladeDiscPolicyEntry 2 }
+
+cucsComputeBladeDiscPolicyRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BladeDiscPolicy:rn managed object property"
+ ::= { cucsComputeBladeDiscPolicyEntry 3 }
+
+cucsComputeBladeDiscPolicyAction OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BladeDiscPolicy:action managed object property"
+ ::= { cucsComputeBladeDiscPolicyEntry 4 }
+
+cucsComputeBladeDiscPolicyDescr OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BladeDiscPolicy:descr managed object property"
+ ::= { cucsComputeBladeDiscPolicyEntry 5 }
+
+cucsComputeBladeDiscPolicyIntId OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BladeDiscPolicy:intId managed object property"
+ ::= { cucsComputeBladeDiscPolicyEntry 6 }
+
+cucsComputeBladeDiscPolicyName OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BladeDiscPolicy:name managed object property"
+ ::= { cucsComputeBladeDiscPolicyEntry 7 }
+
+cucsComputeBladeDiscPolicyQualifier OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BladeDiscPolicy:qualifier managed
+ object property"
+ ::= { cucsComputeBladeDiscPolicyEntry 8 }
+
+cucsComputeBladeDiscPolicyScrubPolicyName OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BladeDiscPolicy:scrubPolicyName
+ managed object property"
+ ::= { cucsComputeBladeDiscPolicyEntry 9 }
+
+cucsComputeBladeDiscPolicyPolicyLevel OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BladeDiscPolicy:policyLevel
+ managed object property"
+ ::= { cucsComputeBladeDiscPolicyEntry 10 }
+
+cucsComputeBladeDiscPolicyPolicyOwner OBJECT-TYPE
+ SYNTAX CucsPolicyPolicyOwner
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BladeDiscPolicy:policyOwner
+ managed object property"
+ ::= { cucsComputeBladeDiscPolicyEntry 11 }
+
+cucsComputeBladeEpTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputeBladeEpEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BladeEp managed object table"
+ ::= { cucsComputeObjects 66 }
+
+cucsComputeBladeEpEntry OBJECT-TYPE
+ SYNTAX CucsComputeBladeEpEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputeBladeEpTable table."
+ INDEX { cucsComputeBladeEpInstanceId }
+ ::= { cucsComputeBladeEpTable 1 }
+
+CucsComputeBladeEpEntry ::= SEQUENCE {
+ cucsComputeBladeEpInstanceId CucsManagedObjectId,
+ cucsComputeBladeEpDn CucsManagedObjectDn,
+ cucsComputeBladeEpRn SnmpAdminString,
+ cucsComputeBladeEpAdminState CucsComputeAdminState,
+ cucsComputeBladeEpChassisId Gauge32,
+ cucsComputeBladeEpEpDn SnmpAdminString,
+ cucsComputeBladeEpId CucsComputeBladeEpId,
+ cucsComputeBladeEpOperQualifierReason SnmpAdminString,
+ cucsComputeBladeEpOperState CucsLsOperState,
+ cucsComputeBladeEpPeerPresence CucsEquipmentSlotStatus,
+ cucsComputeBladeEpPresence CucsEquipmentSlotStatus,
+ cucsComputeBladeEpSlotId CucsComputeBladeEpSlotId
+}
+
+cucsComputeBladeEpInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputeBladeEpEntry 1 }
+
+cucsComputeBladeEpDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BladeEp:dn managed object property"
+ ::= { cucsComputeBladeEpEntry 2 }
+
+cucsComputeBladeEpRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BladeEp:rn managed object property"
+ ::= { cucsComputeBladeEpEntry 3 }
+
+cucsComputeBladeEpAdminState OBJECT-TYPE
+ SYNTAX CucsComputeAdminState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BladeEp:adminState managed object property"
+ ::= { cucsComputeBladeEpEntry 4 }
+
+cucsComputeBladeEpChassisId OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BladeEp:chassisId managed object property"
+ ::= { cucsComputeBladeEpEntry 5 }
+
+cucsComputeBladeEpEpDn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BladeEp:epDn managed object property"
+ ::= { cucsComputeBladeEpEntry 6 }
+
+cucsComputeBladeEpId OBJECT-TYPE
+ SYNTAX CucsComputeBladeEpId
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BladeEp:id managed object property"
+ ::= { cucsComputeBladeEpEntry 7 }
+
+cucsComputeBladeEpOperQualifierReason OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BladeEp:operQualifierReason
+ managed object property"
+ ::= { cucsComputeBladeEpEntry 8 }
+
+cucsComputeBladeEpOperState OBJECT-TYPE
+ SYNTAX CucsLsOperState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BladeEp:operState managed object property"
+ ::= { cucsComputeBladeEpEntry 9 }
+
+cucsComputeBladeEpPeerPresence OBJECT-TYPE
+ SYNTAX CucsEquipmentSlotStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BladeEp:peerPresence managed object property"
+ ::= { cucsComputeBladeEpEntry 10 }
+
+cucsComputeBladeEpPresence OBJECT-TYPE
+ SYNTAX CucsEquipmentSlotStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BladeEp:presence managed object property"
+ ::= { cucsComputeBladeEpEntry 11 }
+
+cucsComputeBladeEpSlotId OBJECT-TYPE
+ SYNTAX CucsComputeBladeEpSlotId
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BladeEp:slotId managed object property"
+ ::= { cucsComputeBladeEpEntry 12 }
+
+cucsComputeBladeFsmTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputeBladeFsmEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BladeFsm managed object table"
+ ::= { cucsComputeObjects 48 }
+
+cucsComputeBladeFsmEntry OBJECT-TYPE
+ SYNTAX CucsComputeBladeFsmEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputeBladeFsmTable table."
+ INDEX { cucsComputeBladeFsmInstanceId }
+ ::= { cucsComputeBladeFsmTable 1 }
+
+CucsComputeBladeFsmEntry ::= SEQUENCE {
+ cucsComputeBladeFsmInstanceId CucsManagedObjectId,
+ cucsComputeBladeFsmDn CucsManagedObjectDn,
+ cucsComputeBladeFsmRn SnmpAdminString,
+ cucsComputeBladeFsmCompletionTime DateAndTime,
+ cucsComputeBladeFsmCurrentFsm CucsComputeBladeFsmCurrentFsm,
+ cucsComputeBladeFsmDescrData SnmpAdminString,
+ cucsComputeBladeFsmFsmStatus CucsFsmFsmStageStatus,
+ cucsComputeBladeFsmProgress Gauge32,
+ cucsComputeBladeFsmRmtErrCode Gauge32,
+ cucsComputeBladeFsmRmtErrDescr SnmpAdminString,
+ cucsComputeBladeFsmRmtRslt CucsConditionRemoteInvRslt
+}
+
+cucsComputeBladeFsmInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputeBladeFsmEntry 1 }
+
+cucsComputeBladeFsmDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BladeFsm:dn managed object property"
+ ::= { cucsComputeBladeFsmEntry 2 }
+
+cucsComputeBladeFsmRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BladeFsm:rn managed object property"
+ ::= { cucsComputeBladeFsmEntry 3 }
+
+cucsComputeBladeFsmCompletionTime OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BladeFsm:completionTime managed
+ object property"
+ ::= { cucsComputeBladeFsmEntry 4 }
+
+cucsComputeBladeFsmCurrentFsm OBJECT-TYPE
+ SYNTAX CucsComputeBladeFsmCurrentFsm
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BladeFsm:currentFsm managed object property"
+ ::= { cucsComputeBladeFsmEntry 5 }
+
+cucsComputeBladeFsmDescrData OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BladeFsm:descr managed object property"
+ ::= { cucsComputeBladeFsmEntry 6 }
+
+cucsComputeBladeFsmFsmStatus OBJECT-TYPE
+ SYNTAX CucsFsmFsmStageStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BladeFsm:fsmStatus managed object property"
+ ::= { cucsComputeBladeFsmEntry 7 }
+
+cucsComputeBladeFsmProgress OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BladeFsm:progress managed object property"
+ ::= { cucsComputeBladeFsmEntry 8 }
+
+cucsComputeBladeFsmRmtErrCode OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BladeFsm:rmtErrCode managed object property"
+ ::= { cucsComputeBladeFsmEntry 9 }
+
+cucsComputeBladeFsmRmtErrDescr OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BladeFsm:rmtErrDescr managed object property"
+ ::= { cucsComputeBladeFsmEntry 10 }
+
+cucsComputeBladeFsmRmtRslt OBJECT-TYPE
+ SYNTAX CucsConditionRemoteInvRslt
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BladeFsm:rmtRslt managed object property"
+ ::= { cucsComputeBladeFsmEntry 11 }
+
+cucsComputeBladeFsmStageTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputeBladeFsmStageEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BladeFsmStage managed object table"
+ ::= { cucsComputeObjects 49 }
+
+cucsComputeBladeFsmStageEntry OBJECT-TYPE
+ SYNTAX CucsComputeBladeFsmStageEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputeBladeFsmStageTable table."
+ INDEX { cucsComputeBladeFsmStageInstanceId }
+ ::= { cucsComputeBladeFsmStageTable 1 }
+
+CucsComputeBladeFsmStageEntry ::= SEQUENCE {
+ cucsComputeBladeFsmStageInstanceId CucsManagedObjectId,
+ cucsComputeBladeFsmStageDn CucsManagedObjectDn,
+ cucsComputeBladeFsmStageRn SnmpAdminString,
+ cucsComputeBladeFsmStageDescrData SnmpAdminString,
+ cucsComputeBladeFsmStageLastUpdateTime DateAndTime,
+ cucsComputeBladeFsmStageName CucsComputeBladeFsmStageName,
+ cucsComputeBladeFsmStageOrder Gauge32,
+ cucsComputeBladeFsmStageRetry Gauge32,
+ cucsComputeBladeFsmStageStageStatus CucsFsmFsmStageStatus
+}
+
+cucsComputeBladeFsmStageInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputeBladeFsmStageEntry 1 }
+
+cucsComputeBladeFsmStageDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BladeFsmStage:dn managed object property"
+ ::= { cucsComputeBladeFsmStageEntry 2 }
+
+cucsComputeBladeFsmStageRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BladeFsmStage:rn managed object property"
+ ::= { cucsComputeBladeFsmStageEntry 3 }
+
+cucsComputeBladeFsmStageDescrData OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BladeFsmStage:descr managed object property"
+ ::= { cucsComputeBladeFsmStageEntry 4 }
+
+cucsComputeBladeFsmStageLastUpdateTime OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BladeFsmStage:lastUpdateTime
+ managed object property"
+ ::= { cucsComputeBladeFsmStageEntry 5 }
+
+cucsComputeBladeFsmStageName OBJECT-TYPE
+ SYNTAX CucsComputeBladeFsmStageName
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BladeFsmStage:name managed object property"
+ ::= { cucsComputeBladeFsmStageEntry 6 }
+
+cucsComputeBladeFsmStageOrder OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BladeFsmStage:order managed object property"
+ ::= { cucsComputeBladeFsmStageEntry 7 }
+
+cucsComputeBladeFsmStageRetry OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BladeFsmStage:retry managed object property"
+ ::= { cucsComputeBladeFsmStageEntry 8 }
+
+cucsComputeBladeFsmStageStageStatus OBJECT-TYPE
+ SYNTAX CucsFsmFsmStageStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BladeFsmStage:stageStatus managed
+ object property"
+ ::= { cucsComputeBladeFsmStageEntry 9 }
+
+cucsComputeBladeFsmTaskTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputeBladeFsmTaskEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BladeFsmTask managed object table"
+ ::= { cucsComputeObjects 4 }
+
+cucsComputeBladeFsmTaskEntry OBJECT-TYPE
+ SYNTAX CucsComputeBladeFsmTaskEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputeBladeFsmTaskTable table."
+ INDEX { cucsComputeBladeFsmTaskInstanceId }
+ ::= { cucsComputeBladeFsmTaskTable 1 }
+
+CucsComputeBladeFsmTaskEntry ::= SEQUENCE {
+ cucsComputeBladeFsmTaskInstanceId CucsManagedObjectId,
+ cucsComputeBladeFsmTaskDn CucsManagedObjectDn,
+ cucsComputeBladeFsmTaskRn SnmpAdminString,
+ cucsComputeBladeFsmTaskCompletion CucsFsmCompletion,
+ cucsComputeBladeFsmTaskFlags CucsComputeBladeFsmTaskFlags,
+ cucsComputeBladeFsmTaskItem CucsComputeBladeFsmTaskItem,
+ cucsComputeBladeFsmTaskSeqId Gauge32
+}
+
+cucsComputeBladeFsmTaskInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputeBladeFsmTaskEntry 1 }
+
+cucsComputeBladeFsmTaskDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BladeFsmTask:dn managed object property"
+ ::= { cucsComputeBladeFsmTaskEntry 2 }
+
+cucsComputeBladeFsmTaskRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BladeFsmTask:rn managed object property"
+ ::= { cucsComputeBladeFsmTaskEntry 3 }
+
+cucsComputeBladeFsmTaskCompletion OBJECT-TYPE
+ SYNTAX CucsFsmCompletion
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BladeFsmTask:completion managed
+ object property"
+ ::= { cucsComputeBladeFsmTaskEntry 4 }
+
+cucsComputeBladeFsmTaskFlags OBJECT-TYPE
+ SYNTAX CucsComputeBladeFsmTaskFlags
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BladeFsmTask:flags managed object property"
+ ::= { cucsComputeBladeFsmTaskEntry 5 }
+
+cucsComputeBladeFsmTaskItem OBJECT-TYPE
+ SYNTAX CucsComputeBladeFsmTaskItem
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BladeFsmTask:item managed object property"
+ ::= { cucsComputeBladeFsmTaskEntry 6 }
+
+cucsComputeBladeFsmTaskSeqId OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BladeFsmTask:seqId managed object property"
+ ::= { cucsComputeBladeFsmTaskEntry 7 }
+
+cucsComputeBladeInheritPolicyTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputeBladeInheritPolicyEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BladeInheritPolicy managed object table"
+ ::= { cucsComputeObjects 5 }
+
+cucsComputeBladeInheritPolicyEntry OBJECT-TYPE
+ SYNTAX CucsComputeBladeInheritPolicyEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputeBladeInheritPolicyTable table."
+ INDEX { cucsComputeBladeInheritPolicyInstanceId }
+ ::= { cucsComputeBladeInheritPolicyTable 1 }
+
+CucsComputeBladeInheritPolicyEntry ::= SEQUENCE {
+ cucsComputeBladeInheritPolicyInstanceId CucsManagedObjectId,
+ cucsComputeBladeInheritPolicyDn CucsManagedObjectDn,
+ cucsComputeBladeInheritPolicyRn SnmpAdminString,
+ cucsComputeBladeInheritPolicyDescr SnmpAdminString,
+ cucsComputeBladeInheritPolicyDstDn SnmpAdminString,
+ cucsComputeBladeInheritPolicyIntId SnmpAdminString,
+ cucsComputeBladeInheritPolicyName SnmpAdminString,
+ cucsComputeBladeInheritPolicyQualifier SnmpAdminString,
+ cucsComputeBladeInheritPolicyPolicyLevel Gauge32,
+ cucsComputeBladeInheritPolicyPolicyOwner CucsPolicyPolicyOwner,
+ cucsComputeBladeInheritPolicyOperQualifier SnmpAdminString
+}
+
+cucsComputeBladeInheritPolicyInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputeBladeInheritPolicyEntry 1 }
+
+cucsComputeBladeInheritPolicyDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BladeInheritPolicy:dn managed object property"
+ ::= { cucsComputeBladeInheritPolicyEntry 2 }
+
+cucsComputeBladeInheritPolicyRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BladeInheritPolicy:rn managed object property"
+ ::= { cucsComputeBladeInheritPolicyEntry 3 }
+
+cucsComputeBladeInheritPolicyDescr OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BladeInheritPolicy:descr managed
+ object property"
+ ::= { cucsComputeBladeInheritPolicyEntry 4 }
+
+cucsComputeBladeInheritPolicyDstDn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BladeInheritPolicy:dstDn managed
+ object property"
+ ::= { cucsComputeBladeInheritPolicyEntry 5 }
+
+cucsComputeBladeInheritPolicyIntId OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BladeInheritPolicy:intId managed
+ object property"
+ ::= { cucsComputeBladeInheritPolicyEntry 6 }
+
+cucsComputeBladeInheritPolicyName OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BladeInheritPolicy:name managed
+ object property"
+ ::= { cucsComputeBladeInheritPolicyEntry 7 }
+
+cucsComputeBladeInheritPolicyQualifier OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BladeInheritPolicy:qualifier
+ managed object property"
+ ::= { cucsComputeBladeInheritPolicyEntry 8 }
+
+cucsComputeBladeInheritPolicyPolicyLevel OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BladeInheritPolicy:policyLevel
+ managed object property"
+ ::= { cucsComputeBladeInheritPolicyEntry 9 }
+
+cucsComputeBladeInheritPolicyPolicyOwner OBJECT-TYPE
+ SYNTAX CucsPolicyPolicyOwner
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BladeInheritPolicy:policyOwner
+ managed object property"
+ ::= { cucsComputeBladeInheritPolicyEntry 10 }
+
+cucsComputeBladeInheritPolicyOperQualifier OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BladeInheritPolicy:operQualifier
+ managed object property"
+ ::= { cucsComputeBladeInheritPolicyEntry 11 }
+
+cucsComputeBoardTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputeBoardEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Board managed object table"
+ ::= { cucsComputeObjects 6 }
+
+cucsComputeBoardEntry OBJECT-TYPE
+ SYNTAX CucsComputeBoardEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputeBoardTable table."
+ INDEX { cucsComputeBoardInstanceId }
+ ::= { cucsComputeBoardTable 1 }
+
+CucsComputeBoardEntry ::= SEQUENCE {
+ cucsComputeBoardInstanceId CucsManagedObjectId,
+ cucsComputeBoardDn CucsManagedObjectDn,
+ cucsComputeBoardRn SnmpAdminString,
+ cucsComputeBoardCmosVoltage CucsEquipmentSensorThresholdStatus,
+ cucsComputeBoardId Gauge32,
+ cucsComputeBoardModel SnmpAdminString,
+ cucsComputeBoardOperPower CucsEquipmentPowerState,
+ cucsComputeBoardOperState CucsEquipmentOperability,
+ cucsComputeBoardOperability CucsEquipmentOperability,
+ cucsComputeBoardPerf CucsEquipmentSensorThresholdStatus,
+ cucsComputeBoardPower CucsComputeABoardPower,
+ cucsComputeBoardPresence CucsEquipmentPresence,
+ cucsComputeBoardRevision SnmpAdminString,
+ cucsComputeBoardSerial SnmpAdminString,
+ cucsComputeBoardThermal CucsEquipmentSensorThresholdStatus,
+ cucsComputeBoardVendor SnmpAdminString,
+ cucsComputeBoardVoltage CucsEquipmentSensorThresholdStatus,
+ cucsComputeBoardOperQualifierReason SnmpAdminString,
+ cucsComputeBoardPowerUsage CucsEquipmentSensorThresholdStatus,
+ cucsComputeBoardFaultQualifier SnmpAdminString,
+ cucsComputeBoardLocationDn SnmpAdminString,
+ cucsComputeBoardCpuTypeDescription SnmpAdminString
+}
+
+cucsComputeBoardInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputeBoardEntry 1 }
+
+cucsComputeBoardDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Board:dn managed object property"
+ ::= { cucsComputeBoardEntry 2 }
+
+cucsComputeBoardRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Board:rn managed object property"
+ ::= { cucsComputeBoardEntry 3 }
+
+cucsComputeBoardCmosVoltage OBJECT-TYPE
+ SYNTAX CucsEquipmentSensorThresholdStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Board:cmosVoltage managed object property"
+ ::= { cucsComputeBoardEntry 4 }
+
+cucsComputeBoardId OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Board:id managed object property"
+ ::= { cucsComputeBoardEntry 5 }
+
+cucsComputeBoardModel OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Board:model managed object property"
+ ::= { cucsComputeBoardEntry 6 }
+
+cucsComputeBoardOperPower OBJECT-TYPE
+ SYNTAX CucsEquipmentPowerState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Board:operPower managed object property"
+ ::= { cucsComputeBoardEntry 7 }
+
+cucsComputeBoardOperState OBJECT-TYPE
+ SYNTAX CucsEquipmentOperability
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Board:operState managed object property"
+ ::= { cucsComputeBoardEntry 8 }
+
+cucsComputeBoardOperability OBJECT-TYPE
+ SYNTAX CucsEquipmentOperability
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Board:operability managed object property"
+ ::= { cucsComputeBoardEntry 9 }
+
+cucsComputeBoardPerf OBJECT-TYPE
+ SYNTAX CucsEquipmentSensorThresholdStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Board:perf managed object property"
+ ::= { cucsComputeBoardEntry 10 }
+
+cucsComputeBoardPower OBJECT-TYPE
+ SYNTAX CucsComputeABoardPower
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Board:power managed object property"
+ ::= { cucsComputeBoardEntry 11 }
+
+cucsComputeBoardPresence OBJECT-TYPE
+ SYNTAX CucsEquipmentPresence
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Board:presence managed object property"
+ ::= { cucsComputeBoardEntry 12 }
+
+cucsComputeBoardRevision OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Board:revision managed object property"
+ ::= { cucsComputeBoardEntry 13 }
+
+cucsComputeBoardSerial OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Board:serial managed object property"
+ ::= { cucsComputeBoardEntry 14 }
+
+cucsComputeBoardThermal OBJECT-TYPE
+ SYNTAX CucsEquipmentSensorThresholdStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Board:thermal managed object property"
+ ::= { cucsComputeBoardEntry 15 }
+
+cucsComputeBoardVendor OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Board:vendor managed object property"
+ ::= { cucsComputeBoardEntry 16 }
+
+cucsComputeBoardVoltage OBJECT-TYPE
+ SYNTAX CucsEquipmentSensorThresholdStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Board:voltage managed object property"
+ ::= { cucsComputeBoardEntry 17 }
+
+cucsComputeBoardOperQualifierReason OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Board:operQualifierReason managed
+ object property"
+ ::= { cucsComputeBoardEntry 18 }
+
+cucsComputeBoardPowerUsage OBJECT-TYPE
+ SYNTAX CucsEquipmentSensorThresholdStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Board:powerUsage managed object property"
+ ::= { cucsComputeBoardEntry 19 }
+
+cucsComputeBoardFaultQualifier OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Board:faultQualifier managed object property"
+ ::= { cucsComputeBoardEntry 20 }
+
+cucsComputeBoardLocationDn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Board:locationDn managed object property"
+ ::= { cucsComputeBoardEntry 21 }
+
+cucsComputeBoardCpuTypeDescription OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Board:cpuTypeDescription managed
+ object property"
+ ::= { cucsComputeBoardEntry 23 }
+
+cucsComputeBoardConnectorTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputeBoardConnectorEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BoardConnector managed object table"
+ ::= { cucsComputeObjects 63 }
+
+cucsComputeBoardConnectorEntry OBJECT-TYPE
+ SYNTAX CucsComputeBoardConnectorEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputeBoardConnectorTable table."
+ INDEX { cucsComputeBoardConnectorInstanceId }
+ ::= { cucsComputeBoardConnectorTable 1 }
+
+CucsComputeBoardConnectorEntry ::= SEQUENCE {
+ cucsComputeBoardConnectorInstanceId CucsManagedObjectId,
+ cucsComputeBoardConnectorDn CucsManagedObjectDn,
+ cucsComputeBoardConnectorRn SnmpAdminString,
+ cucsComputeBoardConnectorBoardConnectorType CucsEquipmentBoardConnectorType,
+ cucsComputeBoardConnectorMasterSlotId Gauge32,
+ cucsComputeBoardConnectorSlaveSlotId Gauge32
+}
+
+cucsComputeBoardConnectorInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputeBoardConnectorEntry 1 }
+
+cucsComputeBoardConnectorDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BoardConnector:dn managed object property"
+ ::= { cucsComputeBoardConnectorEntry 2 }
+
+cucsComputeBoardConnectorRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BoardConnector:rn managed object property"
+ ::= { cucsComputeBoardConnectorEntry 3 }
+
+cucsComputeBoardConnectorBoardConnectorType OBJECT-TYPE
+ SYNTAX CucsEquipmentBoardConnectorType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BoardConnector:boardConnectorType
+ managed object property"
+ ::= { cucsComputeBoardConnectorEntry 4 }
+
+cucsComputeBoardConnectorMasterSlotId OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BoardConnector:masterSlotId
+ managed object property"
+ ::= { cucsComputeBoardConnectorEntry 5 }
+
+cucsComputeBoardConnectorSlaveSlotId OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BoardConnector:slaveSlotId managed
+ object property"
+ ::= { cucsComputeBoardConnectorEntry 6 }
+
+cucsComputeBoardControllerTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputeBoardControllerEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BoardController managed object table"
+ ::= { cucsComputeObjects 7 }
+
+cucsComputeBoardControllerEntry OBJECT-TYPE
+ SYNTAX CucsComputeBoardControllerEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputeBoardControllerTable table."
+ INDEX { cucsComputeBoardControllerInstanceId }
+ ::= { cucsComputeBoardControllerTable 1 }
+
+CucsComputeBoardControllerEntry ::= SEQUENCE {
+ cucsComputeBoardControllerInstanceId CucsManagedObjectId,
+ cucsComputeBoardControllerDn CucsManagedObjectDn,
+ cucsComputeBoardControllerRn SnmpAdminString,
+ cucsComputeBoardControllerId Gauge32,
+ cucsComputeBoardControllerModel SnmpAdminString,
+ cucsComputeBoardControllerOperState CucsEquipmentOperability,
+ cucsComputeBoardControllerOperability CucsEquipmentOperability,
+ cucsComputeBoardControllerPerf CucsEquipmentSensorThresholdStatus,
+ cucsComputeBoardControllerPower CucsEquipmentPowerState,
+ cucsComputeBoardControllerPresence CucsEquipmentPresence,
+ cucsComputeBoardControllerRevision SnmpAdminString,
+ cucsComputeBoardControllerSerial SnmpAdminString,
+ cucsComputeBoardControllerThermal CucsEquipmentSensorThresholdStatus,
+ cucsComputeBoardControllerVendor SnmpAdminString,
+ cucsComputeBoardControllerVoltage CucsEquipmentSensorThresholdStatus,
+ cucsComputeBoardControllerOperQualifierReason SnmpAdminString,
+ cucsComputeBoardControllerLocationDn SnmpAdminString
+}
+
+cucsComputeBoardControllerInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputeBoardControllerEntry 1 }
+
+cucsComputeBoardControllerDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BoardController:dn managed object property"
+ ::= { cucsComputeBoardControllerEntry 2 }
+
+cucsComputeBoardControllerRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BoardController:rn managed object property"
+ ::= { cucsComputeBoardControllerEntry 3 }
+
+cucsComputeBoardControllerId OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BoardController:id managed object property"
+ ::= { cucsComputeBoardControllerEntry 4 }
+
+cucsComputeBoardControllerModel OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BoardController:model managed object property"
+ ::= { cucsComputeBoardControllerEntry 5 }
+
+cucsComputeBoardControllerOperState OBJECT-TYPE
+ SYNTAX CucsEquipmentOperability
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BoardController:operState managed
+ object property"
+ ::= { cucsComputeBoardControllerEntry 6 }
+
+cucsComputeBoardControllerOperability OBJECT-TYPE
+ SYNTAX CucsEquipmentOperability
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BoardController:operability
+ managed object property"
+ ::= { cucsComputeBoardControllerEntry 7 }
+
+cucsComputeBoardControllerPerf OBJECT-TYPE
+ SYNTAX CucsEquipmentSensorThresholdStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BoardController:perf managed object property"
+ ::= { cucsComputeBoardControllerEntry 8 }
+
+cucsComputeBoardControllerPower OBJECT-TYPE
+ SYNTAX CucsEquipmentPowerState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BoardController:power managed object property"
+ ::= { cucsComputeBoardControllerEntry 9 }
+
+cucsComputeBoardControllerPresence OBJECT-TYPE
+ SYNTAX CucsEquipmentPresence
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BoardController:presence managed
+ object property"
+ ::= { cucsComputeBoardControllerEntry 10 }
+
+cucsComputeBoardControllerRevision OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BoardController:revision managed
+ object property"
+ ::= { cucsComputeBoardControllerEntry 11 }
+
+cucsComputeBoardControllerSerial OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BoardController:serial managed object property"
+ ::= { cucsComputeBoardControllerEntry 12 }
+
+cucsComputeBoardControllerThermal OBJECT-TYPE
+ SYNTAX CucsEquipmentSensorThresholdStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BoardController:thermal managed
+ object property"
+ ::= { cucsComputeBoardControllerEntry 13 }
+
+cucsComputeBoardControllerVendor OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BoardController:vendor managed object property"
+ ::= { cucsComputeBoardControllerEntry 14 }
+
+cucsComputeBoardControllerVoltage OBJECT-TYPE
+ SYNTAX CucsEquipmentSensorThresholdStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BoardController:voltage managed
+ object property"
+ ::= { cucsComputeBoardControllerEntry 15 }
+
+cucsComputeBoardControllerOperQualifierReason OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BoardController:operQualifierReason
+ managed object property"
+ ::= { cucsComputeBoardControllerEntry 16 }
+
+cucsComputeBoardControllerLocationDn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:BoardController:locationDn managed
+ object property"
+ ::= { cucsComputeBoardControllerEntry 17 }
+
+cucsComputeCartridgeTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputeCartridgeEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Cartridge managed object table"
+ ::= { cucsComputeObjects 71 }
+
+cucsComputeCartridgeEntry OBJECT-TYPE
+ SYNTAX CucsComputeCartridgeEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputeCartridgeTable table."
+ INDEX { cucsComputeCartridgeInstanceId }
+ ::= { cucsComputeCartridgeTable 1 }
+
+CucsComputeCartridgeEntry ::= SEQUENCE {
+ cucsComputeCartridgeInstanceId CucsManagedObjectId,
+ cucsComputeCartridgeDn CucsManagedObjectDn,
+ cucsComputeCartridgeRn SnmpAdminString,
+ cucsComputeCartridgeChassisId Gauge32,
+ cucsComputeCartridgeDiscovery CucsComputeCartridgeDiscovery,
+ cucsComputeCartridgeFltAggr Unsigned64,
+ cucsComputeCartridgeId Gauge32,
+ cucsComputeCartridgeLc CucsComputeAdminTrigger,
+ cucsComputeCartridgeLcTs DateAndTime,
+ cucsComputeCartridgeModel SnmpAdminString,
+ cucsComputeCartridgeOperQualifierReason SnmpAdminString,
+ cucsComputeCartridgeOperState CucsEquipmentOperability,
+ cucsComputeCartridgeOperability CucsEquipmentOperability,
+ cucsComputeCartridgePerf CucsEquipmentSensorThresholdStatus,
+ cucsComputeCartridgePower CucsEquipmentPowerState,
+ cucsComputeCartridgePresence CucsEquipmentPresence,
+ cucsComputeCartridgeRevision SnmpAdminString,
+ cucsComputeCartridgeSerial SnmpAdminString,
+ cucsComputeCartridgeSlotId CucsComputeCartridgeSlotId,
+ cucsComputeCartridgeThermal CucsEquipmentSensorThresholdStatus,
+ cucsComputeCartridgeVendor SnmpAdminString,
+ cucsComputeCartridgeVoltage CucsEquipmentSensorThresholdStatus
+}
+
+cucsComputeCartridgeInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputeCartridgeEntry 1 }
+
+cucsComputeCartridgeDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Cartridge:dn managed object property"
+ ::= { cucsComputeCartridgeEntry 2 }
+
+cucsComputeCartridgeRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Cartridge:rn managed object property"
+ ::= { cucsComputeCartridgeEntry 3 }
+
+cucsComputeCartridgeChassisId OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Cartridge:chassisId managed object property"
+ ::= { cucsComputeCartridgeEntry 4 }
+
+cucsComputeCartridgeDiscovery OBJECT-TYPE
+ SYNTAX CucsComputeCartridgeDiscovery
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Cartridge:discovery managed object property"
+ ::= { cucsComputeCartridgeEntry 5 }
+
+cucsComputeCartridgeFltAggr OBJECT-TYPE
+ SYNTAX Unsigned64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Cartridge:fltAggr managed object property"
+ ::= { cucsComputeCartridgeEntry 6 }
+
+cucsComputeCartridgeId OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Cartridge:id managed object property"
+ ::= { cucsComputeCartridgeEntry 7 }
+
+cucsComputeCartridgeLc OBJECT-TYPE
+ SYNTAX CucsComputeAdminTrigger
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Cartridge:lc managed object property"
+ ::= { cucsComputeCartridgeEntry 8 }
+
+cucsComputeCartridgeLcTs OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Cartridge:lcTs managed object property"
+ ::= { cucsComputeCartridgeEntry 9 }
+
+cucsComputeCartridgeModel OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Cartridge:model managed object property"
+ ::= { cucsComputeCartridgeEntry 10 }
+
+cucsComputeCartridgeOperQualifierReason OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Cartridge:operQualifierReason
+ managed object property"
+ ::= { cucsComputeCartridgeEntry 11 }
+
+cucsComputeCartridgeOperState OBJECT-TYPE
+ SYNTAX CucsEquipmentOperability
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Cartridge:operState managed object property"
+ ::= { cucsComputeCartridgeEntry 12 }
+
+cucsComputeCartridgeOperability OBJECT-TYPE
+ SYNTAX CucsEquipmentOperability
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Cartridge:operability managed object property"
+ ::= { cucsComputeCartridgeEntry 13 }
+
+cucsComputeCartridgePerf OBJECT-TYPE
+ SYNTAX CucsEquipmentSensorThresholdStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Cartridge:perf managed object property"
+ ::= { cucsComputeCartridgeEntry 14 }
+
+cucsComputeCartridgePower OBJECT-TYPE
+ SYNTAX CucsEquipmentPowerState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Cartridge:power managed object property"
+ ::= { cucsComputeCartridgeEntry 15 }
+
+cucsComputeCartridgePresence OBJECT-TYPE
+ SYNTAX CucsEquipmentPresence
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Cartridge:presence managed object property"
+ ::= { cucsComputeCartridgeEntry 16 }
+
+cucsComputeCartridgeRevision OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Cartridge:revision managed object property"
+ ::= { cucsComputeCartridgeEntry 17 }
+
+cucsComputeCartridgeSerial OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Cartridge:serial managed object property"
+ ::= { cucsComputeCartridgeEntry 18 }
+
+cucsComputeCartridgeSlotId OBJECT-TYPE
+ SYNTAX CucsComputeCartridgeSlotId
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Cartridge:slotId managed object property"
+ ::= { cucsComputeCartridgeEntry 19 }
+
+cucsComputeCartridgeThermal OBJECT-TYPE
+ SYNTAX CucsEquipmentSensorThresholdStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Cartridge:thermal managed object property"
+ ::= { cucsComputeCartridgeEntry 20 }
+
+cucsComputeCartridgeVendor OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Cartridge:vendor managed object property"
+ ::= { cucsComputeCartridgeEntry 21 }
+
+cucsComputeCartridgeVoltage OBJECT-TYPE
+ SYNTAX CucsEquipmentSensorThresholdStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Cartridge:voltage managed object property"
+ ::= { cucsComputeCartridgeEntry 22 }
+
+cucsComputeChassisConnPolicyTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputeChassisConnPolicyEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ChassisConnPolicy managed object table"
+ ::= { cucsComputeObjects 46 }
+
+cucsComputeChassisConnPolicyEntry OBJECT-TYPE
+ SYNTAX CucsComputeChassisConnPolicyEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputeChassisConnPolicyTable table."
+ INDEX { cucsComputeChassisConnPolicyInstanceId }
+ ::= { cucsComputeChassisConnPolicyTable 1 }
+
+CucsComputeChassisConnPolicyEntry ::= SEQUENCE {
+ cucsComputeChassisConnPolicyInstanceId CucsManagedObjectId,
+ cucsComputeChassisConnPolicyDn CucsManagedObjectDn,
+ cucsComputeChassisConnPolicyRn SnmpAdminString,
+ cucsComputeChassisConnPolicyAdminState CucsComputeAdminLinkAggregation,
+ cucsComputeChassisConnPolicyChassisId CucsComputeChassisConnPolicyChassisId,
+ cucsComputeChassisConnPolicyDescr SnmpAdminString,
+ cucsComputeChassisConnPolicyIntId SnmpAdminString,
+ cucsComputeChassisConnPolicyName SnmpAdminString,
+ cucsComputeChassisConnPolicyQualifier SnmpAdminString,
+ cucsComputeChassisConnPolicySwitchId CucsNetworkSwitchId,
+ cucsComputeChassisConnPolicyPolicyLevel Gauge32,
+ cucsComputeChassisConnPolicyPolicyOwner CucsPolicyPolicyOwner
+}
+
+cucsComputeChassisConnPolicyInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputeChassisConnPolicyEntry 1 }
+
+cucsComputeChassisConnPolicyDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ChassisConnPolicy:dn managed object property"
+ ::= { cucsComputeChassisConnPolicyEntry 2 }
+
+cucsComputeChassisConnPolicyRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ChassisConnPolicy:rn managed object property"
+ ::= { cucsComputeChassisConnPolicyEntry 3 }
+
+cucsComputeChassisConnPolicyAdminState OBJECT-TYPE
+ SYNTAX CucsComputeAdminLinkAggregation
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ChassisConnPolicy:adminState
+ managed object property"
+ ::= { cucsComputeChassisConnPolicyEntry 4 }
+
+cucsComputeChassisConnPolicyChassisId OBJECT-TYPE
+ SYNTAX CucsComputeChassisConnPolicyChassisId
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ChassisConnPolicy:chassisId
+ managed object property"
+ ::= { cucsComputeChassisConnPolicyEntry 5 }
+
+cucsComputeChassisConnPolicyDescr OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ChassisConnPolicy:descr managed
+ object property"
+ ::= { cucsComputeChassisConnPolicyEntry 6 }
+
+cucsComputeChassisConnPolicyIntId OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ChassisConnPolicy:intId managed
+ object property"
+ ::= { cucsComputeChassisConnPolicyEntry 7 }
+
+cucsComputeChassisConnPolicyName OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ChassisConnPolicy:name managed object property"
+ ::= { cucsComputeChassisConnPolicyEntry 8 }
+
+cucsComputeChassisConnPolicyQualifier OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ChassisConnPolicy:qualifier
+ managed object property"
+ ::= { cucsComputeChassisConnPolicyEntry 9 }
+
+cucsComputeChassisConnPolicySwitchId OBJECT-TYPE
+ SYNTAX CucsNetworkSwitchId
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ChassisConnPolicy:switchId managed
+ object property"
+ ::= { cucsComputeChassisConnPolicyEntry 10 }
+
+cucsComputeChassisConnPolicyPolicyLevel OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ChassisConnPolicy:policyLevel
+ managed object property"
+ ::= { cucsComputeChassisConnPolicyEntry 11 }
+
+cucsComputeChassisConnPolicyPolicyOwner OBJECT-TYPE
+ SYNTAX CucsPolicyPolicyOwner
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ChassisConnPolicy:policyOwner
+ managed object property"
+ ::= { cucsComputeChassisConnPolicyEntry 12 }
+
+cucsComputeChassisDiscPolicyTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputeChassisDiscPolicyEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ChassisDiscPolicy managed object table"
+ ::= { cucsComputeObjects 8 }
+
+cucsComputeChassisDiscPolicyEntry OBJECT-TYPE
+ SYNTAX CucsComputeChassisDiscPolicyEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputeChassisDiscPolicyTable table."
+ INDEX { cucsComputeChassisDiscPolicyInstanceId }
+ ::= { cucsComputeChassisDiscPolicyTable 1 }
+
+CucsComputeChassisDiscPolicyEntry ::= SEQUENCE {
+ cucsComputeChassisDiscPolicyInstanceId CucsManagedObjectId,
+ cucsComputeChassisDiscPolicyDn CucsManagedObjectDn,
+ cucsComputeChassisDiscPolicyRn SnmpAdminString,
+ cucsComputeChassisDiscPolicyAction CucsComputeChassisDiscAction,
+ cucsComputeChassisDiscPolicyDescr SnmpAdminString,
+ cucsComputeChassisDiscPolicyIntId SnmpAdminString,
+ cucsComputeChassisDiscPolicyName SnmpAdminString,
+ cucsComputeChassisDiscPolicyQualifier SnmpAdminString,
+ cucsComputeChassisDiscPolicyRebalance CucsComputeConnectivityRebalancing,
+ cucsComputeChassisDiscPolicyLinkAggregationPref CucsComputeLinkAggregation,
+ cucsComputeChassisDiscPolicyPolicyLevel Gauge32,
+ cucsComputeChassisDiscPolicyPolicyOwner CucsPolicyPolicyOwner,
+ cucsComputeChassisDiscPolicyMulticastHwHash CucsComputeChassisDiscPolicyMulticastHwHash
+}
+
+cucsComputeChassisDiscPolicyInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputeChassisDiscPolicyEntry 1 }
+
+cucsComputeChassisDiscPolicyDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ChassisDiscPolicy:dn managed object property"
+ ::= { cucsComputeChassisDiscPolicyEntry 2 }
+
+cucsComputeChassisDiscPolicyRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ChassisDiscPolicy:rn managed object property"
+ ::= { cucsComputeChassisDiscPolicyEntry 3 }
+
+cucsComputeChassisDiscPolicyAction OBJECT-TYPE
+ SYNTAX CucsComputeChassisDiscAction
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ChassisDiscPolicy:action managed
+ object property"
+ ::= { cucsComputeChassisDiscPolicyEntry 4 }
+
+cucsComputeChassisDiscPolicyDescr OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ChassisDiscPolicy:descr managed
+ object property"
+ ::= { cucsComputeChassisDiscPolicyEntry 5 }
+
+cucsComputeChassisDiscPolicyIntId OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ChassisDiscPolicy:intId managed
+ object property"
+ ::= { cucsComputeChassisDiscPolicyEntry 6 }
+
+cucsComputeChassisDiscPolicyName OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ChassisDiscPolicy:name managed object property"
+ ::= { cucsComputeChassisDiscPolicyEntry 7 }
+
+cucsComputeChassisDiscPolicyQualifier OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ChassisDiscPolicy:qualifier
+ managed object property"
+ ::= { cucsComputeChassisDiscPolicyEntry 8 }
+
+cucsComputeChassisDiscPolicyRebalance OBJECT-TYPE
+ SYNTAX CucsComputeConnectivityRebalancing
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ChassisDiscPolicy:rebalance
+ managed object property"
+ ::= { cucsComputeChassisDiscPolicyEntry 9 }
+
+cucsComputeChassisDiscPolicyLinkAggregationPref OBJECT-TYPE
+ SYNTAX CucsComputeLinkAggregation
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ChassisDiscPolicy:linkAggregationPref
+ managed object property"
+ ::= { cucsComputeChassisDiscPolicyEntry 10 }
+
+cucsComputeChassisDiscPolicyPolicyLevel OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ChassisDiscPolicy:policyLevel
+ managed object property"
+ ::= { cucsComputeChassisDiscPolicyEntry 11 }
+
+cucsComputeChassisDiscPolicyPolicyOwner OBJECT-TYPE
+ SYNTAX CucsPolicyPolicyOwner
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ChassisDiscPolicy:policyOwner
+ managed object property"
+ ::= { cucsComputeChassisDiscPolicyEntry 12 }
+
+cucsComputeChassisDiscPolicyMulticastHwHash OBJECT-TYPE
+ SYNTAX CucsComputeChassisDiscPolicyMulticastHwHash
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ChassisDiscPolicy:multicastHwHash
+ managed object property"
+ ::= { cucsComputeChassisDiscPolicyEntry 13 }
+
+cucsComputeChassisQualTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputeChassisQualEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ChassisQual managed object table"
+ ::= { cucsComputeObjects 9 }
+
+cucsComputeChassisQualEntry OBJECT-TYPE
+ SYNTAX CucsComputeChassisQualEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputeChassisQualTable table."
+ INDEX { cucsComputeChassisQualInstanceId }
+ ::= { cucsComputeChassisQualTable 1 }
+
+CucsComputeChassisQualEntry ::= SEQUENCE {
+ cucsComputeChassisQualInstanceId CucsManagedObjectId,
+ cucsComputeChassisQualDn CucsManagedObjectDn,
+ cucsComputeChassisQualRn SnmpAdminString,
+ cucsComputeChassisQualMaxId CucsComputeChassisQualMaxId,
+ cucsComputeChassisQualMinId CucsComputeChassisQualMinId
+}
+
+cucsComputeChassisQualInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputeChassisQualEntry 1 }
+
+cucsComputeChassisQualDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ChassisQual:dn managed object property"
+ ::= { cucsComputeChassisQualEntry 2 }
+
+cucsComputeChassisQualRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ChassisQual:rn managed object property"
+ ::= { cucsComputeChassisQualEntry 3 }
+
+cucsComputeChassisQualMaxId OBJECT-TYPE
+ SYNTAX CucsComputeChassisQualMaxId
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ChassisQual:maxId managed object property"
+ ::= { cucsComputeChassisQualEntry 4 }
+
+cucsComputeChassisQualMinId OBJECT-TYPE
+ SYNTAX CucsComputeChassisQualMinId
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ChassisQual:minId managed object property"
+ ::= { cucsComputeChassisQualEntry 5 }
+
+cucsComputeConstraintDefTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputeConstraintDefEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ConstraintDef managed object table"
+ ::= { cucsComputeObjects 67 }
+
+cucsComputeConstraintDefEntry OBJECT-TYPE
+ SYNTAX CucsComputeConstraintDefEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputeConstraintDefTable table."
+ INDEX { cucsComputeConstraintDefInstanceId }
+ ::= { cucsComputeConstraintDefTable 1 }
+
+CucsComputeConstraintDefEntry ::= SEQUENCE {
+ cucsComputeConstraintDefInstanceId CucsManagedObjectId,
+ cucsComputeConstraintDefDn CucsManagedObjectDn,
+ cucsComputeConstraintDefRn SnmpAdminString,
+ cucsComputeConstraintDefConstraintType CucsComputeEquipmentConstraintType,
+ cucsComputeConstraintDefDescr SnmpAdminString,
+ cucsComputeConstraintDefHwModel SnmpAdminString,
+ cucsComputeConstraintDefHwRevision SnmpAdminString,
+ cucsComputeConstraintDefHwVendor SnmpAdminString,
+ cucsComputeConstraintDefIntId SnmpAdminString,
+ cucsComputeConstraintDefName SnmpAdminString,
+ cucsComputeConstraintDefPolicyLevel Gauge32,
+ cucsComputeConstraintDefPolicyOwner CucsPolicyPolicyOwner
+}
+
+cucsComputeConstraintDefInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputeConstraintDefEntry 1 }
+
+cucsComputeConstraintDefDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ConstraintDef:dn managed object property"
+ ::= { cucsComputeConstraintDefEntry 2 }
+
+cucsComputeConstraintDefRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ConstraintDef:rn managed object property"
+ ::= { cucsComputeConstraintDefEntry 3 }
+
+cucsComputeConstraintDefConstraintType OBJECT-TYPE
+ SYNTAX CucsComputeEquipmentConstraintType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ConstraintDef:constraintType
+ managed object property"
+ ::= { cucsComputeConstraintDefEntry 4 }
+
+cucsComputeConstraintDefDescr OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ConstraintDef:descr managed object property"
+ ::= { cucsComputeConstraintDefEntry 5 }
+
+cucsComputeConstraintDefHwModel OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ConstraintDef:hwModel managed object property"
+ ::= { cucsComputeConstraintDefEntry 6 }
+
+cucsComputeConstraintDefHwRevision OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ConstraintDef:hwRevision managed
+ object property"
+ ::= { cucsComputeConstraintDefEntry 7 }
+
+cucsComputeConstraintDefHwVendor OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ConstraintDef:hwVendor managed object property"
+ ::= { cucsComputeConstraintDefEntry 8 }
+
+cucsComputeConstraintDefIntId OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ConstraintDef:intId managed object property"
+ ::= { cucsComputeConstraintDefEntry 9 }
+
+cucsComputeConstraintDefName OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ConstraintDef:name managed object property"
+ ::= { cucsComputeConstraintDefEntry 10 }
+
+cucsComputeConstraintDefPolicyLevel OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ConstraintDef:policyLevel managed
+ object property"
+ ::= { cucsComputeConstraintDefEntry 11 }
+
+cucsComputeConstraintDefPolicyOwner OBJECT-TYPE
+ SYNTAX CucsPolicyPolicyOwner
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ConstraintDef:policyOwner managed
+ object property"
+ ::= { cucsComputeConstraintDefEntry 12 }
+
+cucsComputeDefaultsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputeDefaultsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Defaults managed object table"
+ ::= { cucsComputeObjects 10 }
+
+cucsComputeDefaultsEntry OBJECT-TYPE
+ SYNTAX CucsComputeDefaultsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputeDefaultsTable table."
+ INDEX { cucsComputeDefaultsInstanceId }
+ ::= { cucsComputeDefaultsTable 1 }
+
+CucsComputeDefaultsEntry ::= SEQUENCE {
+ cucsComputeDefaultsInstanceId CucsManagedObjectId,
+ cucsComputeDefaultsDn CucsManagedObjectDn,
+ cucsComputeDefaultsRn SnmpAdminString
+}
+
+cucsComputeDefaultsInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputeDefaultsEntry 1 }
+
+cucsComputeDefaultsDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Defaults:dn managed object property"
+ ::= { cucsComputeDefaultsEntry 2 }
+
+cucsComputeDefaultsRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Defaults:rn managed object property"
+ ::= { cucsComputeDefaultsEntry 3 }
+
+cucsComputeExtBoardTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputeExtBoardEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ExtBoard managed object table"
+ ::= { cucsComputeObjects 64 }
+
+cucsComputeExtBoardEntry OBJECT-TYPE
+ SYNTAX CucsComputeExtBoardEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputeExtBoardTable table."
+ INDEX { cucsComputeExtBoardInstanceId }
+ ::= { cucsComputeExtBoardTable 1 }
+
+CucsComputeExtBoardEntry ::= SEQUENCE {
+ cucsComputeExtBoardInstanceId CucsManagedObjectId,
+ cucsComputeExtBoardDn CucsManagedObjectDn,
+ cucsComputeExtBoardRn SnmpAdminString,
+ cucsComputeExtBoardBoardAggregationRole CucsEquipmentBoardAggregationRole,
+ cucsComputeExtBoardChassisId Gauge32,
+ cucsComputeExtBoardCmosVoltage CucsEquipmentSensorThresholdStatus,
+ cucsComputeExtBoardConnPath CucsEquipmentConnectionStatus,
+ cucsComputeExtBoardConnStatus CucsEquipmentConnectionStatus,
+ cucsComputeExtBoardFaultQualifier SnmpAdminString,
+ cucsComputeExtBoardId Gauge32,
+ cucsComputeExtBoardLocationDn SnmpAdminString,
+ cucsComputeExtBoardManagingInst CucsNetworkSwitchId,
+ cucsComputeExtBoardModel SnmpAdminString,
+ cucsComputeExtBoardOperPower CucsEquipmentPowerState,
+ cucsComputeExtBoardOperQualifierReason SnmpAdminString,
+ cucsComputeExtBoardOperState CucsEquipmentOperability,
+ cucsComputeExtBoardOperability CucsEquipmentOperability,
+ cucsComputeExtBoardPerf CucsEquipmentSensorThresholdStatus,
+ cucsComputeExtBoardPower CucsComputeABoardPower,
+ cucsComputeExtBoardPowerUsage CucsEquipmentSensorThresholdStatus,
+ cucsComputeExtBoardPresence CucsEquipmentPresence,
+ cucsComputeExtBoardRevision SnmpAdminString,
+ cucsComputeExtBoardSerial SnmpAdminString,
+ cucsComputeExtBoardSlotId Gauge32,
+ cucsComputeExtBoardThermal CucsEquipmentSensorThresholdStatus,
+ cucsComputeExtBoardVendor SnmpAdminString,
+ cucsComputeExtBoardVoltage CucsEquipmentSensorThresholdStatus,
+ cucsComputeExtBoardDiscoveryStatus CucsEquipmentConnectionStatus
+}
+
+cucsComputeExtBoardInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputeExtBoardEntry 1 }
+
+cucsComputeExtBoardDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ExtBoard:dn managed object property"
+ ::= { cucsComputeExtBoardEntry 2 }
+
+cucsComputeExtBoardRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ExtBoard:rn managed object property"
+ ::= { cucsComputeExtBoardEntry 3 }
+
+cucsComputeExtBoardBoardAggregationRole OBJECT-TYPE
+ SYNTAX CucsEquipmentBoardAggregationRole
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ExtBoard:boardAggregationRole
+ managed object property"
+ ::= { cucsComputeExtBoardEntry 4 }
+
+cucsComputeExtBoardChassisId OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ExtBoard:chassisId managed object property"
+ ::= { cucsComputeExtBoardEntry 5 }
+
+cucsComputeExtBoardCmosVoltage OBJECT-TYPE
+ SYNTAX CucsEquipmentSensorThresholdStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ExtBoard:cmosVoltage managed object property"
+ ::= { cucsComputeExtBoardEntry 6 }
+
+cucsComputeExtBoardConnPath OBJECT-TYPE
+ SYNTAX CucsEquipmentConnectionStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ExtBoard:connPath managed object property"
+ ::= { cucsComputeExtBoardEntry 7 }
+
+cucsComputeExtBoardConnStatus OBJECT-TYPE
+ SYNTAX CucsEquipmentConnectionStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ExtBoard:connStatus managed object property"
+ ::= { cucsComputeExtBoardEntry 8 }
+
+cucsComputeExtBoardFaultQualifier OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ExtBoard:faultQualifier managed
+ object property"
+ ::= { cucsComputeExtBoardEntry 9 }
+
+cucsComputeExtBoardId OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ExtBoard:id managed object property"
+ ::= { cucsComputeExtBoardEntry 10 }
+
+cucsComputeExtBoardLocationDn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ExtBoard:locationDn managed object property"
+ ::= { cucsComputeExtBoardEntry 11 }
+
+cucsComputeExtBoardManagingInst OBJECT-TYPE
+ SYNTAX CucsNetworkSwitchId
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ExtBoard:managingInst managed object property"
+ ::= { cucsComputeExtBoardEntry 12 }
+
+cucsComputeExtBoardModel OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ExtBoard:model managed object property"
+ ::= { cucsComputeExtBoardEntry 13 }
+
+cucsComputeExtBoardOperPower OBJECT-TYPE
+ SYNTAX CucsEquipmentPowerState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ExtBoard:operPower managed object property"
+ ::= { cucsComputeExtBoardEntry 14 }
+
+cucsComputeExtBoardOperQualifierReason OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ExtBoard:operQualifierReason
+ managed object property"
+ ::= { cucsComputeExtBoardEntry 15 }
+
+cucsComputeExtBoardOperState OBJECT-TYPE
+ SYNTAX CucsEquipmentOperability
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ExtBoard:operState managed object property"
+ ::= { cucsComputeExtBoardEntry 16 }
+
+cucsComputeExtBoardOperability OBJECT-TYPE
+ SYNTAX CucsEquipmentOperability
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ExtBoard:operability managed object property"
+ ::= { cucsComputeExtBoardEntry 17 }
+
+cucsComputeExtBoardPerf OBJECT-TYPE
+ SYNTAX CucsEquipmentSensorThresholdStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ExtBoard:perf managed object property"
+ ::= { cucsComputeExtBoardEntry 18 }
+
+cucsComputeExtBoardPower OBJECT-TYPE
+ SYNTAX CucsComputeABoardPower
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ExtBoard:power managed object property"
+ ::= { cucsComputeExtBoardEntry 19 }
+
+cucsComputeExtBoardPowerUsage OBJECT-TYPE
+ SYNTAX CucsEquipmentSensorThresholdStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ExtBoard:powerUsage managed object property"
+ ::= { cucsComputeExtBoardEntry 20 }
+
+cucsComputeExtBoardPresence OBJECT-TYPE
+ SYNTAX CucsEquipmentPresence
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ExtBoard:presence managed object property"
+ ::= { cucsComputeExtBoardEntry 21 }
+
+cucsComputeExtBoardRevision OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ExtBoard:revision managed object property"
+ ::= { cucsComputeExtBoardEntry 22 }
+
+cucsComputeExtBoardSerial OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ExtBoard:serial managed object property"
+ ::= { cucsComputeExtBoardEntry 23 }
+
+cucsComputeExtBoardSlotId OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ExtBoard:slotId managed object property"
+ ::= { cucsComputeExtBoardEntry 24 }
+
+cucsComputeExtBoardThermal OBJECT-TYPE
+ SYNTAX CucsEquipmentSensorThresholdStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ExtBoard:thermal managed object property"
+ ::= { cucsComputeExtBoardEntry 25 }
+
+cucsComputeExtBoardVendor OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ExtBoard:vendor managed object property"
+ ::= { cucsComputeExtBoardEntry 26 }
+
+cucsComputeExtBoardVoltage OBJECT-TYPE
+ SYNTAX CucsEquipmentSensorThresholdStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ExtBoard:voltage managed object property"
+ ::= { cucsComputeExtBoardEntry 27 }
+
+cucsComputeExtBoardDiscoveryStatus OBJECT-TYPE
+ SYNTAX CucsEquipmentConnectionStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ExtBoard:discoveryStatus managed
+ object property"
+ ::= { cucsComputeExtBoardEntry 28 }
+
+cucsComputeFwSyncAckTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputeFwSyncAckEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:FwSyncAck managed object table"
+ ::= { cucsComputeObjects 60 }
+
+cucsComputeFwSyncAckEntry OBJECT-TYPE
+ SYNTAX CucsComputeFwSyncAckEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputeFwSyncAckTable table."
+ INDEX { cucsComputeFwSyncAckInstanceId }
+ ::= { cucsComputeFwSyncAckTable 1 }
+
+CucsComputeFwSyncAckEntry ::= SEQUENCE {
+ cucsComputeFwSyncAckInstanceId CucsManagedObjectId,
+ cucsComputeFwSyncAckDn CucsManagedObjectDn,
+ cucsComputeFwSyncAckRn SnmpAdminString,
+ cucsComputeFwSyncAckAcked DateAndTime,
+ cucsComputeFwSyncAckAckedBy SnmpAdminString,
+ cucsComputeFwSyncAckAdminState CucsTrigAdminState,
+ cucsComputeFwSyncAckAutoDelete TruthValue,
+ cucsComputeFwSyncAckChangeBy SnmpAdminString,
+ cucsComputeFwSyncAckChangeDetails CucsTrigAckChangeDetails,
+ cucsComputeFwSyncAckChanges CucsTrigAckChanges,
+ cucsComputeFwSyncAckDescr SnmpAdminString,
+ cucsComputeFwSyncAckDisr CucsTrigAckDisr,
+ cucsComputeFwSyncAckIgnoreCap TruthValue,
+ cucsComputeFwSyncAckIntId SnmpAdminString,
+ cucsComputeFwSyncAckModified DateAndTime,
+ cucsComputeFwSyncAckName SnmpAdminString,
+ cucsComputeFwSyncAckOperScheduler SnmpAdminString,
+ cucsComputeFwSyncAckOperState CucsTrigAckOperState,
+ cucsComputeFwSyncAckPolicyLevel Gauge32,
+ cucsComputeFwSyncAckPolicyOwner CucsPolicyPolicyOwner,
+ cucsComputeFwSyncAckPrevOperState CucsTrigAckPrevOperState,
+ cucsComputeFwSyncAckScheduler SnmpAdminString,
+ cucsComputeFwSyncAckTriggerConfigState CucsTrigTrigState
+}
+
+cucsComputeFwSyncAckInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputeFwSyncAckEntry 1 }
+
+cucsComputeFwSyncAckDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:FwSyncAck:dn managed object property"
+ ::= { cucsComputeFwSyncAckEntry 2 }
+
+cucsComputeFwSyncAckRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:FwSyncAck:rn managed object property"
+ ::= { cucsComputeFwSyncAckEntry 3 }
+
+cucsComputeFwSyncAckAcked OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:FwSyncAck:acked managed object property"
+ ::= { cucsComputeFwSyncAckEntry 4 }
+
+cucsComputeFwSyncAckAckedBy OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:FwSyncAck:ackedBy managed object property"
+ ::= { cucsComputeFwSyncAckEntry 5 }
+
+cucsComputeFwSyncAckAdminState OBJECT-TYPE
+ SYNTAX CucsTrigAdminState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:FwSyncAck:adminState managed object property"
+ ::= { cucsComputeFwSyncAckEntry 6 }
+
+cucsComputeFwSyncAckAutoDelete OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:FwSyncAck:autoDelete managed object property"
+ ::= { cucsComputeFwSyncAckEntry 7 }
+
+cucsComputeFwSyncAckChangeBy OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:FwSyncAck:changeBy managed object property"
+ ::= { cucsComputeFwSyncAckEntry 8 }
+
+cucsComputeFwSyncAckChangeDetails OBJECT-TYPE
+ SYNTAX CucsTrigAckChangeDetails
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:FwSyncAck:changeDetails managed
+ object property"
+ ::= { cucsComputeFwSyncAckEntry 9 }
+
+cucsComputeFwSyncAckChanges OBJECT-TYPE
+ SYNTAX CucsTrigAckChanges
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:FwSyncAck:changes managed object property"
+ ::= { cucsComputeFwSyncAckEntry 10 }
+
+cucsComputeFwSyncAckDescr OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:FwSyncAck:descr managed object property"
+ ::= { cucsComputeFwSyncAckEntry 11 }
+
+cucsComputeFwSyncAckDisr OBJECT-TYPE
+ SYNTAX CucsTrigAckDisr
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:FwSyncAck:disr managed object property"
+ ::= { cucsComputeFwSyncAckEntry 12 }
+
+cucsComputeFwSyncAckIgnoreCap OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:FwSyncAck:ignoreCap managed object property"
+ ::= { cucsComputeFwSyncAckEntry 13 }
+
+cucsComputeFwSyncAckIntId OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:FwSyncAck:intId managed object property"
+ ::= { cucsComputeFwSyncAckEntry 14 }
+
+cucsComputeFwSyncAckModified OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:FwSyncAck:modified managed object property"
+ ::= { cucsComputeFwSyncAckEntry 15 }
+
+cucsComputeFwSyncAckName OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:FwSyncAck:name managed object property"
+ ::= { cucsComputeFwSyncAckEntry 16 }
+
+cucsComputeFwSyncAckOperScheduler OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:FwSyncAck:operScheduler managed
+ object property"
+ ::= { cucsComputeFwSyncAckEntry 17 }
+
+cucsComputeFwSyncAckOperState OBJECT-TYPE
+ SYNTAX CucsTrigAckOperState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:FwSyncAck:operState managed object property"
+ ::= { cucsComputeFwSyncAckEntry 18 }
+
+cucsComputeFwSyncAckPolicyLevel OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:FwSyncAck:policyLevel managed object property"
+ ::= { cucsComputeFwSyncAckEntry 19 }
+
+cucsComputeFwSyncAckPolicyOwner OBJECT-TYPE
+ SYNTAX CucsPolicyPolicyOwner
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:FwSyncAck:policyOwner managed object property"
+ ::= { cucsComputeFwSyncAckEntry 20 }
+
+cucsComputeFwSyncAckPrevOperState OBJECT-TYPE
+ SYNTAX CucsTrigAckPrevOperState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:FwSyncAck:prevOperState managed
+ object property"
+ ::= { cucsComputeFwSyncAckEntry 21 }
+
+cucsComputeFwSyncAckScheduler OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:FwSyncAck:scheduler managed object property"
+ ::= { cucsComputeFwSyncAckEntry 22 }
+
+cucsComputeFwSyncAckTriggerConfigState OBJECT-TYPE
+ SYNTAX CucsTrigTrigState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:FwSyncAck:triggerConfigState
+ managed object property"
+ ::= { cucsComputeFwSyncAckEntry 23 }
+
+cucsComputeHealthLedSensorAlarmTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputeHealthLedSensorAlarmEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:HealthLedSensorAlarm managed object table"
+ ::= { cucsComputeObjects 59 }
+
+cucsComputeHealthLedSensorAlarmEntry OBJECT-TYPE
+ SYNTAX CucsComputeHealthLedSensorAlarmEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputeHealthLedSensorAlarmTable table."
+ INDEX { cucsComputeHealthLedSensorAlarmInstanceId }
+ ::= { cucsComputeHealthLedSensorAlarmTable 1 }
+
+CucsComputeHealthLedSensorAlarmEntry ::= SEQUENCE {
+ cucsComputeHealthLedSensorAlarmInstanceId CucsManagedObjectId,
+ cucsComputeHealthLedSensorAlarmDn CucsManagedObjectDn,
+ cucsComputeHealthLedSensorAlarmRn SnmpAdminString,
+ cucsComputeHealthLedSensorAlarmAlarmDesc SnmpAdminString,
+ cucsComputeHealthLedSensorAlarmAlarmSeverity CucsComputeAlarmSeverity,
+ cucsComputeHealthLedSensorAlarmSensorId Gauge32,
+ cucsComputeHealthLedSensorAlarmSensorName SnmpAdminString
+}
+
+cucsComputeHealthLedSensorAlarmInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputeHealthLedSensorAlarmEntry 1 }
+
+cucsComputeHealthLedSensorAlarmDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:HealthLedSensorAlarm:dn managed
+ object property"
+ ::= { cucsComputeHealthLedSensorAlarmEntry 2 }
+
+cucsComputeHealthLedSensorAlarmRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:HealthLedSensorAlarm:rn managed
+ object property"
+ ::= { cucsComputeHealthLedSensorAlarmEntry 3 }
+
+cucsComputeHealthLedSensorAlarmAlarmDesc OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:HealthLedSensorAlarm:alarmDesc
+ managed object property"
+ ::= { cucsComputeHealthLedSensorAlarmEntry 4 }
+
+cucsComputeHealthLedSensorAlarmAlarmSeverity OBJECT-TYPE
+ SYNTAX CucsComputeAlarmSeverity
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:HealthLedSensorAlarm:alarmSeverity
+ managed object property"
+ ::= { cucsComputeHealthLedSensorAlarmEntry 5 }
+
+cucsComputeHealthLedSensorAlarmSensorId OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:HealthLedSensorAlarm:sensorId
+ managed object property"
+ ::= { cucsComputeHealthLedSensorAlarmEntry 6 }
+
+cucsComputeHealthLedSensorAlarmSensorName OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:HealthLedSensorAlarm:sensorName
+ managed object property"
+ ::= { cucsComputeHealthLedSensorAlarmEntry 7 }
+
+cucsComputeIOHubTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputeIOHubEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:IOHub managed object table"
+ ::= { cucsComputeObjects 11 }
+
+cucsComputeIOHubEntry OBJECT-TYPE
+ SYNTAX CucsComputeIOHubEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputeIOHubTable table."
+ INDEX { cucsComputeIOHubInstanceId }
+ ::= { cucsComputeIOHubTable 1 }
+
+CucsComputeIOHubEntry ::= SEQUENCE {
+ cucsComputeIOHubInstanceId CucsManagedObjectId,
+ cucsComputeIOHubDn CucsManagedObjectDn,
+ cucsComputeIOHubRn SnmpAdminString,
+ cucsComputeIOHubId Gauge32,
+ cucsComputeIOHubModel SnmpAdminString,
+ cucsComputeIOHubOperState CucsEquipmentOperability,
+ cucsComputeIOHubOperability CucsEquipmentOperability,
+ cucsComputeIOHubPerf CucsEquipmentSensorThresholdStatus,
+ cucsComputeIOHubPower CucsEquipmentPowerState,
+ cucsComputeIOHubPresence CucsEquipmentPresence,
+ cucsComputeIOHubRevision SnmpAdminString,
+ cucsComputeIOHubSerial SnmpAdminString,
+ cucsComputeIOHubThermal CucsEquipmentSensorThresholdStatus,
+ cucsComputeIOHubVendor SnmpAdminString,
+ cucsComputeIOHubVoltage CucsEquipmentSensorThresholdStatus,
+ cucsComputeIOHubOperQualifierReason SnmpAdminString,
+ cucsComputeIOHubLocationDn SnmpAdminString
+}
+
+cucsComputeIOHubInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputeIOHubEntry 1 }
+
+cucsComputeIOHubDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:IOHub:dn managed object property"
+ ::= { cucsComputeIOHubEntry 2 }
+
+cucsComputeIOHubRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:IOHub:rn managed object property"
+ ::= { cucsComputeIOHubEntry 3 }
+
+cucsComputeIOHubId OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:IOHub:id managed object property"
+ ::= { cucsComputeIOHubEntry 4 }
+
+cucsComputeIOHubModel OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:IOHub:model managed object property"
+ ::= { cucsComputeIOHubEntry 5 }
+
+cucsComputeIOHubOperState OBJECT-TYPE
+ SYNTAX CucsEquipmentOperability
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:IOHub:operState managed object property"
+ ::= { cucsComputeIOHubEntry 6 }
+
+cucsComputeIOHubOperability OBJECT-TYPE
+ SYNTAX CucsEquipmentOperability
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:IOHub:operability managed object property"
+ ::= { cucsComputeIOHubEntry 7 }
+
+cucsComputeIOHubPerf OBJECT-TYPE
+ SYNTAX CucsEquipmentSensorThresholdStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:IOHub:perf managed object property"
+ ::= { cucsComputeIOHubEntry 8 }
+
+cucsComputeIOHubPower OBJECT-TYPE
+ SYNTAX CucsEquipmentPowerState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:IOHub:power managed object property"
+ ::= { cucsComputeIOHubEntry 9 }
+
+cucsComputeIOHubPresence OBJECT-TYPE
+ SYNTAX CucsEquipmentPresence
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:IOHub:presence managed object property"
+ ::= { cucsComputeIOHubEntry 10 }
+
+cucsComputeIOHubRevision OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:IOHub:revision managed object property"
+ ::= { cucsComputeIOHubEntry 11 }
+
+cucsComputeIOHubSerial OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:IOHub:serial managed object property"
+ ::= { cucsComputeIOHubEntry 12 }
+
+cucsComputeIOHubThermal OBJECT-TYPE
+ SYNTAX CucsEquipmentSensorThresholdStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:IOHub:thermal managed object property"
+ ::= { cucsComputeIOHubEntry 13 }
+
+cucsComputeIOHubVendor OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:IOHub:vendor managed object property"
+ ::= { cucsComputeIOHubEntry 14 }
+
+cucsComputeIOHubVoltage OBJECT-TYPE
+ SYNTAX CucsEquipmentSensorThresholdStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:IOHub:voltage managed object property"
+ ::= { cucsComputeIOHubEntry 15 }
+
+cucsComputeIOHubOperQualifierReason OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:IOHub:operQualifierReason managed
+ object property"
+ ::= { cucsComputeIOHubEntry 16 }
+
+cucsComputeIOHubLocationDn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:IOHub:locationDn managed object property"
+ ::= { cucsComputeIOHubEntry 17 }
+
+cucsComputeIOHubEnvStatsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputeIOHubEnvStatsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:IOHubEnvStats managed object table"
+ ::= { cucsComputeObjects 12 }
+
+cucsComputeIOHubEnvStatsEntry OBJECT-TYPE
+ SYNTAX CucsComputeIOHubEnvStatsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputeIOHubEnvStatsTable table."
+ INDEX { cucsComputeIOHubEnvStatsInstanceId }
+ ::= { cucsComputeIOHubEnvStatsTable 1 }
+
+CucsComputeIOHubEnvStatsEntry ::= SEQUENCE {
+ cucsComputeIOHubEnvStatsInstanceId CucsManagedObjectId,
+ cucsComputeIOHubEnvStatsDn CucsManagedObjectDn,
+ cucsComputeIOHubEnvStatsRn SnmpAdminString,
+ cucsComputeIOHubEnvStatsIntervals Gauge32,
+ cucsComputeIOHubEnvStatsSuspect TruthValue,
+ cucsComputeIOHubEnvStatsTemperature INTEGER,
+ cucsComputeIOHubEnvStatsTemperatureAvg INTEGER,
+ cucsComputeIOHubEnvStatsTemperatureMax INTEGER,
+ cucsComputeIOHubEnvStatsTemperatureMin INTEGER,
+ cucsComputeIOHubEnvStatsThresholded CucsComputeIOHubEnvStatsThresholded,
+ cucsComputeIOHubEnvStatsTimeCollected DateAndTime,
+ cucsComputeIOHubEnvStatsUpdate Gauge32
+}
+
+cucsComputeIOHubEnvStatsInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputeIOHubEnvStatsEntry 1 }
+
+cucsComputeIOHubEnvStatsDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:IOHubEnvStats:dn managed object property"
+ ::= { cucsComputeIOHubEnvStatsEntry 2 }
+
+cucsComputeIOHubEnvStatsRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:IOHubEnvStats:rn managed object property"
+ ::= { cucsComputeIOHubEnvStatsEntry 3 }
+
+cucsComputeIOHubEnvStatsIntervals OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:IOHubEnvStats:intervals managed
+ object property"
+ ::= { cucsComputeIOHubEnvStatsEntry 4 }
+
+cucsComputeIOHubEnvStatsSuspect OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:IOHubEnvStats:suspect managed object property"
+ ::= { cucsComputeIOHubEnvStatsEntry 5 }
+
+cucsComputeIOHubEnvStatsTemperature OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:IOHubEnvStats:temperature managed
+ object property"
+ ::= { cucsComputeIOHubEnvStatsEntry 6 }
+
+cucsComputeIOHubEnvStatsTemperatureAvg OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:IOHubEnvStats:temperatureAvg
+ managed object property"
+ ::= { cucsComputeIOHubEnvStatsEntry 7 }
+
+cucsComputeIOHubEnvStatsTemperatureMax OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:IOHubEnvStats:temperatureMax
+ managed object property"
+ ::= { cucsComputeIOHubEnvStatsEntry 8 }
+
+cucsComputeIOHubEnvStatsTemperatureMin OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:IOHubEnvStats:temperatureMin
+ managed object property"
+ ::= { cucsComputeIOHubEnvStatsEntry 9 }
+
+cucsComputeIOHubEnvStatsThresholded OBJECT-TYPE
+ SYNTAX CucsComputeIOHubEnvStatsThresholded
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:IOHubEnvStats:thresholded managed
+ object property"
+ ::= { cucsComputeIOHubEnvStatsEntry 10 }
+
+cucsComputeIOHubEnvStatsTimeCollected OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:IOHubEnvStats:timeCollected
+ managed object property"
+ ::= { cucsComputeIOHubEnvStatsEntry 11 }
+
+cucsComputeIOHubEnvStatsUpdate OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:IOHubEnvStats:update managed object property"
+ ::= { cucsComputeIOHubEnvStatsEntry 12 }
+
+cucsComputeIOHubEnvStatsHistTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputeIOHubEnvStatsHistEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:IOHubEnvStatsHist managed object table"
+ ::= { cucsComputeObjects 13 }
+
+cucsComputeIOHubEnvStatsHistEntry OBJECT-TYPE
+ SYNTAX CucsComputeIOHubEnvStatsHistEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputeIOHubEnvStatsHistTable table."
+ INDEX { cucsComputeIOHubEnvStatsHistInstanceId }
+ ::= { cucsComputeIOHubEnvStatsHistTable 1 }
+
+CucsComputeIOHubEnvStatsHistEntry ::= SEQUENCE {
+ cucsComputeIOHubEnvStatsHistInstanceId CucsManagedObjectId,
+ cucsComputeIOHubEnvStatsHistDn CucsManagedObjectDn,
+ cucsComputeIOHubEnvStatsHistRn SnmpAdminString,
+ cucsComputeIOHubEnvStatsHistId Unsigned64,
+ cucsComputeIOHubEnvStatsHistMostRecent TruthValue,
+ cucsComputeIOHubEnvStatsHistSuspect TruthValue,
+ cucsComputeIOHubEnvStatsHistTemperature INTEGER,
+ cucsComputeIOHubEnvStatsHistTemperatureAvg INTEGER,
+ cucsComputeIOHubEnvStatsHistTemperatureMax INTEGER,
+ cucsComputeIOHubEnvStatsHistTemperatureMin INTEGER,
+ cucsComputeIOHubEnvStatsHistThresholded CucsComputeIOHubEnvStatsHistThresholded,
+ cucsComputeIOHubEnvStatsHistTimeCollected DateAndTime
+}
+
+cucsComputeIOHubEnvStatsHistInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputeIOHubEnvStatsHistEntry 1 }
+
+cucsComputeIOHubEnvStatsHistDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:IOHubEnvStatsHist:dn managed object property"
+ ::= { cucsComputeIOHubEnvStatsHistEntry 2 }
+
+cucsComputeIOHubEnvStatsHistRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:IOHubEnvStatsHist:rn managed object property"
+ ::= { cucsComputeIOHubEnvStatsHistEntry 3 }
+
+cucsComputeIOHubEnvStatsHistId OBJECT-TYPE
+ SYNTAX Unsigned64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:IOHubEnvStatsHist:id managed object property"
+ ::= { cucsComputeIOHubEnvStatsHistEntry 4 }
+
+cucsComputeIOHubEnvStatsHistMostRecent OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:IOHubEnvStatsHist:mostRecent
+ managed object property"
+ ::= { cucsComputeIOHubEnvStatsHistEntry 5 }
+
+cucsComputeIOHubEnvStatsHistSuspect OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:IOHubEnvStatsHist:suspect managed
+ object property"
+ ::= { cucsComputeIOHubEnvStatsHistEntry 6 }
+
+cucsComputeIOHubEnvStatsHistTemperature OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:IOHubEnvStatsHist:temperature
+ managed object property"
+ ::= { cucsComputeIOHubEnvStatsHistEntry 7 }
+
+cucsComputeIOHubEnvStatsHistTemperatureAvg OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:IOHubEnvStatsHist:temperatureAvg
+ managed object property"
+ ::= { cucsComputeIOHubEnvStatsHistEntry 8 }
+
+cucsComputeIOHubEnvStatsHistTemperatureMax OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:IOHubEnvStatsHist:temperatureMax
+ managed object property"
+ ::= { cucsComputeIOHubEnvStatsHistEntry 9 }
+
+cucsComputeIOHubEnvStatsHistTemperatureMin OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:IOHubEnvStatsHist:temperatureMin
+ managed object property"
+ ::= { cucsComputeIOHubEnvStatsHistEntry 10 }
+
+cucsComputeIOHubEnvStatsHistThresholded OBJECT-TYPE
+ SYNTAX CucsComputeIOHubEnvStatsHistThresholded
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:IOHubEnvStatsHist:thresholded
+ managed object property"
+ ::= { cucsComputeIOHubEnvStatsHistEntry 11 }
+
+cucsComputeIOHubEnvStatsHistTimeCollected OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:IOHubEnvStatsHist:timeCollected
+ managed object property"
+ ::= { cucsComputeIOHubEnvStatsHistEntry 12 }
+
+cucsComputeInstanceIdQualTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputeInstanceIdQualEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:InstanceIdQual managed object table"
+ ::= { cucsComputeObjects 72 }
+
+cucsComputeInstanceIdQualEntry OBJECT-TYPE
+ SYNTAX CucsComputeInstanceIdQualEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputeInstanceIdQualTable table."
+ INDEX { cucsComputeInstanceIdQualInstanceId }
+ ::= { cucsComputeInstanceIdQualTable 1 }
+
+CucsComputeInstanceIdQualEntry ::= SEQUENCE {
+ cucsComputeInstanceIdQualInstanceId CucsManagedObjectId,
+ cucsComputeInstanceIdQualDn CucsManagedObjectDn,
+ cucsComputeInstanceIdQualRn SnmpAdminString,
+ cucsComputeInstanceIdQualMaxId CucsComputeInstanceIdQualMaxId,
+ cucsComputeInstanceIdQualMinId CucsComputeInstanceIdQualMinId
+}
+
+cucsComputeInstanceIdQualInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputeInstanceIdQualEntry 1 }
+
+cucsComputeInstanceIdQualDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:InstanceIdQual:dn managed object property"
+ ::= { cucsComputeInstanceIdQualEntry 2 }
+
+cucsComputeInstanceIdQualRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:InstanceIdQual:rn managed object property"
+ ::= { cucsComputeInstanceIdQualEntry 3 }
+
+cucsComputeInstanceIdQualMaxId OBJECT-TYPE
+ SYNTAX CucsComputeInstanceIdQualMaxId
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:InstanceIdQual:maxId managed object property"
+ ::= { cucsComputeInstanceIdQualEntry 4 }
+
+cucsComputeInstanceIdQualMinId OBJECT-TYPE
+ SYNTAX CucsComputeInstanceIdQualMinId
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:InstanceIdQual:minId managed object property"
+ ::= { cucsComputeInstanceIdQualEntry 5 }
+
+cucsComputeKvmMgmtPolicyTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputeKvmMgmtPolicyEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:KvmMgmtPolicy managed object table"
+ ::= { cucsComputeObjects 65 }
+
+cucsComputeKvmMgmtPolicyEntry OBJECT-TYPE
+ SYNTAX CucsComputeKvmMgmtPolicyEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputeKvmMgmtPolicyTable table."
+ INDEX { cucsComputeKvmMgmtPolicyInstanceId }
+ ::= { cucsComputeKvmMgmtPolicyTable 1 }
+
+CucsComputeKvmMgmtPolicyEntry ::= SEQUENCE {
+ cucsComputeKvmMgmtPolicyInstanceId CucsManagedObjectId,
+ cucsComputeKvmMgmtPolicyDn CucsManagedObjectDn,
+ cucsComputeKvmMgmtPolicyRn SnmpAdminString,
+ cucsComputeKvmMgmtPolicyDescr SnmpAdminString,
+ cucsComputeKvmMgmtPolicyIntId SnmpAdminString,
+ cucsComputeKvmMgmtPolicyName SnmpAdminString,
+ cucsComputeKvmMgmtPolicyPolicyLevel Gauge32,
+ cucsComputeKvmMgmtPolicyPolicyOwner CucsPolicyPolicyOwner,
+ cucsComputeKvmMgmtPolicyVmediaEncryption CucsComputeKvmMgmtPolicyVmediaEncryption
+}
+
+cucsComputeKvmMgmtPolicyInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputeKvmMgmtPolicyEntry 1 }
+
+cucsComputeKvmMgmtPolicyDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:KvmMgmtPolicy:dn managed object property"
+ ::= { cucsComputeKvmMgmtPolicyEntry 2 }
+
+cucsComputeKvmMgmtPolicyRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:KvmMgmtPolicy:rn managed object property"
+ ::= { cucsComputeKvmMgmtPolicyEntry 3 }
+
+cucsComputeKvmMgmtPolicyDescr OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:KvmMgmtPolicy:descr managed object property"
+ ::= { cucsComputeKvmMgmtPolicyEntry 4 }
+
+cucsComputeKvmMgmtPolicyIntId OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:KvmMgmtPolicy:intId managed object property"
+ ::= { cucsComputeKvmMgmtPolicyEntry 5 }
+
+cucsComputeKvmMgmtPolicyName OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:KvmMgmtPolicy:name managed object property"
+ ::= { cucsComputeKvmMgmtPolicyEntry 6 }
+
+cucsComputeKvmMgmtPolicyPolicyLevel OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:KvmMgmtPolicy:policyLevel managed
+ object property"
+ ::= { cucsComputeKvmMgmtPolicyEntry 7 }
+
+cucsComputeKvmMgmtPolicyPolicyOwner OBJECT-TYPE
+ SYNTAX CucsPolicyPolicyOwner
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:KvmMgmtPolicy:policyOwner managed
+ object property"
+ ::= { cucsComputeKvmMgmtPolicyEntry 8 }
+
+cucsComputeKvmMgmtPolicyVmediaEncryption OBJECT-TYPE
+ SYNTAX CucsComputeKvmMgmtPolicyVmediaEncryption
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:KvmMgmtPolicy:vmediaEncryption
+ managed object property"
+ ::= { cucsComputeKvmMgmtPolicyEntry 9 }
+
+cucsComputeMbPowerStatsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputeMbPowerStatsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbPowerStats managed object table"
+ ::= { cucsComputeObjects 14 }
+
+cucsComputeMbPowerStatsEntry OBJECT-TYPE
+ SYNTAX CucsComputeMbPowerStatsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputeMbPowerStatsTable table."
+ INDEX { cucsComputeMbPowerStatsInstanceId }
+ ::= { cucsComputeMbPowerStatsTable 1 }
+
+CucsComputeMbPowerStatsEntry ::= SEQUENCE {
+ cucsComputeMbPowerStatsInstanceId CucsManagedObjectId,
+ cucsComputeMbPowerStatsDn CucsManagedObjectDn,
+ cucsComputeMbPowerStatsRn SnmpAdminString,
+ cucsComputeMbPowerStatsConsumedPower INTEGER,
+ cucsComputeMbPowerStatsConsumedPowerAvg INTEGER,
+ cucsComputeMbPowerStatsConsumedPowerMax INTEGER,
+ cucsComputeMbPowerStatsConsumedPowerMin INTEGER,
+ cucsComputeMbPowerStatsInputCurrent INTEGER,
+ cucsComputeMbPowerStatsInputCurrentAvg INTEGER,
+ cucsComputeMbPowerStatsInputCurrentMax INTEGER,
+ cucsComputeMbPowerStatsInputCurrentMin INTEGER,
+ cucsComputeMbPowerStatsInputVoltage INTEGER,
+ cucsComputeMbPowerStatsInputVoltageAvg INTEGER,
+ cucsComputeMbPowerStatsInputVoltageMax INTEGER,
+ cucsComputeMbPowerStatsInputVoltageMin INTEGER,
+ cucsComputeMbPowerStatsIntervals Gauge32,
+ cucsComputeMbPowerStatsSuspect TruthValue,
+ cucsComputeMbPowerStatsThresholded CucsComputeMbPowerStatsThresholded,
+ cucsComputeMbPowerStatsTimeCollected DateAndTime,
+ cucsComputeMbPowerStatsUpdate Gauge32
+}
+
+cucsComputeMbPowerStatsInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputeMbPowerStatsEntry 1 }
+
+cucsComputeMbPowerStatsDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbPowerStats:dn managed object property"
+ ::= { cucsComputeMbPowerStatsEntry 2 }
+
+cucsComputeMbPowerStatsRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbPowerStats:rn managed object property"
+ ::= { cucsComputeMbPowerStatsEntry 3 }
+
+cucsComputeMbPowerStatsConsumedPower OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbPowerStats:consumedPower managed
+ object property"
+ ::= { cucsComputeMbPowerStatsEntry 4 }
+
+cucsComputeMbPowerStatsConsumedPowerAvg OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbPowerStats:consumedPowerAvg
+ managed object property"
+ ::= { cucsComputeMbPowerStatsEntry 5 }
+
+cucsComputeMbPowerStatsConsumedPowerMax OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbPowerStats:consumedPowerMax
+ managed object property"
+ ::= { cucsComputeMbPowerStatsEntry 6 }
+
+cucsComputeMbPowerStatsConsumedPowerMin OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbPowerStats:consumedPowerMin
+ managed object property"
+ ::= { cucsComputeMbPowerStatsEntry 7 }
+
+cucsComputeMbPowerStatsInputCurrent OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbPowerStats:inputCurrent managed
+ object property"
+ ::= { cucsComputeMbPowerStatsEntry 8 }
+
+cucsComputeMbPowerStatsInputCurrentAvg OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbPowerStats:inputCurrentAvg
+ managed object property"
+ ::= { cucsComputeMbPowerStatsEntry 9 }
+
+cucsComputeMbPowerStatsInputCurrentMax OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbPowerStats:inputCurrentMax
+ managed object property"
+ ::= { cucsComputeMbPowerStatsEntry 10 }
+
+cucsComputeMbPowerStatsInputCurrentMin OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbPowerStats:inputCurrentMin
+ managed object property"
+ ::= { cucsComputeMbPowerStatsEntry 11 }
+
+cucsComputeMbPowerStatsInputVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbPowerStats:inputVoltage managed
+ object property"
+ ::= { cucsComputeMbPowerStatsEntry 12 }
+
+cucsComputeMbPowerStatsInputVoltageAvg OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbPowerStats:inputVoltageAvg
+ managed object property"
+ ::= { cucsComputeMbPowerStatsEntry 13 }
+
+cucsComputeMbPowerStatsInputVoltageMax OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbPowerStats:inputVoltageMax
+ managed object property"
+ ::= { cucsComputeMbPowerStatsEntry 14 }
+
+cucsComputeMbPowerStatsInputVoltageMin OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbPowerStats:inputVoltageMin
+ managed object property"
+ ::= { cucsComputeMbPowerStatsEntry 15 }
+
+cucsComputeMbPowerStatsIntervals OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbPowerStats:intervals managed object property"
+ ::= { cucsComputeMbPowerStatsEntry 16 }
+
+cucsComputeMbPowerStatsSuspect OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbPowerStats:suspect managed object property"
+ ::= { cucsComputeMbPowerStatsEntry 17 }
+
+cucsComputeMbPowerStatsThresholded OBJECT-TYPE
+ SYNTAX CucsComputeMbPowerStatsThresholded
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbPowerStats:thresholded managed
+ object property"
+ ::= { cucsComputeMbPowerStatsEntry 18 }
+
+cucsComputeMbPowerStatsTimeCollected OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbPowerStats:timeCollected managed
+ object property"
+ ::= { cucsComputeMbPowerStatsEntry 19 }
+
+cucsComputeMbPowerStatsUpdate OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbPowerStats:update managed object property"
+ ::= { cucsComputeMbPowerStatsEntry 20 }
+
+cucsComputeMbPowerStatsHistTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputeMbPowerStatsHistEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbPowerStatsHist managed object table"
+ ::= { cucsComputeObjects 15 }
+
+cucsComputeMbPowerStatsHistEntry OBJECT-TYPE
+ SYNTAX CucsComputeMbPowerStatsHistEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputeMbPowerStatsHistTable table."
+ INDEX { cucsComputeMbPowerStatsHistInstanceId }
+ ::= { cucsComputeMbPowerStatsHistTable 1 }
+
+CucsComputeMbPowerStatsHistEntry ::= SEQUENCE {
+ cucsComputeMbPowerStatsHistInstanceId CucsManagedObjectId,
+ cucsComputeMbPowerStatsHistDn CucsManagedObjectDn,
+ cucsComputeMbPowerStatsHistRn SnmpAdminString,
+ cucsComputeMbPowerStatsHistConsumedPower INTEGER,
+ cucsComputeMbPowerStatsHistConsumedPowerAvg INTEGER,
+ cucsComputeMbPowerStatsHistConsumedPowerMax INTEGER,
+ cucsComputeMbPowerStatsHistConsumedPowerMin INTEGER,
+ cucsComputeMbPowerStatsHistId Unsigned64,
+ cucsComputeMbPowerStatsHistInputCurrent INTEGER,
+ cucsComputeMbPowerStatsHistInputCurrentAvg INTEGER,
+ cucsComputeMbPowerStatsHistInputCurrentMax INTEGER,
+ cucsComputeMbPowerStatsHistInputCurrentMin INTEGER,
+ cucsComputeMbPowerStatsHistInputVoltage INTEGER,
+ cucsComputeMbPowerStatsHistInputVoltageAvg INTEGER,
+ cucsComputeMbPowerStatsHistInputVoltageMax INTEGER,
+ cucsComputeMbPowerStatsHistInputVoltageMin INTEGER,
+ cucsComputeMbPowerStatsHistMostRecent TruthValue,
+ cucsComputeMbPowerStatsHistSuspect TruthValue,
+ cucsComputeMbPowerStatsHistThresholded CucsComputeMbPowerStatsHistThresholded,
+ cucsComputeMbPowerStatsHistTimeCollected DateAndTime
+}
+
+cucsComputeMbPowerStatsHistInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputeMbPowerStatsHistEntry 1 }
+
+cucsComputeMbPowerStatsHistDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbPowerStatsHist:dn managed object property"
+ ::= { cucsComputeMbPowerStatsHistEntry 2 }
+
+cucsComputeMbPowerStatsHistRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbPowerStatsHist:rn managed object property"
+ ::= { cucsComputeMbPowerStatsHistEntry 3 }
+
+cucsComputeMbPowerStatsHistConsumedPower OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbPowerStatsHist:consumedPower
+ managed object property"
+ ::= { cucsComputeMbPowerStatsHistEntry 4 }
+
+cucsComputeMbPowerStatsHistConsumedPowerAvg OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbPowerStatsHist:consumedPowerAvg
+ managed object property"
+ ::= { cucsComputeMbPowerStatsHistEntry 5 }
+
+cucsComputeMbPowerStatsHistConsumedPowerMax OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbPowerStatsHist:consumedPowerMax
+ managed object property"
+ ::= { cucsComputeMbPowerStatsHistEntry 6 }
+
+cucsComputeMbPowerStatsHistConsumedPowerMin OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbPowerStatsHist:consumedPowerMin
+ managed object property"
+ ::= { cucsComputeMbPowerStatsHistEntry 7 }
+
+cucsComputeMbPowerStatsHistId OBJECT-TYPE
+ SYNTAX Unsigned64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbPowerStatsHist:id managed object property"
+ ::= { cucsComputeMbPowerStatsHistEntry 8 }
+
+cucsComputeMbPowerStatsHistInputCurrent OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbPowerStatsHist:inputCurrent
+ managed object property"
+ ::= { cucsComputeMbPowerStatsHistEntry 9 }
+
+cucsComputeMbPowerStatsHistInputCurrentAvg OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbPowerStatsHist:inputCurrentAvg
+ managed object property"
+ ::= { cucsComputeMbPowerStatsHistEntry 10 }
+
+cucsComputeMbPowerStatsHistInputCurrentMax OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbPowerStatsHist:inputCurrentMax
+ managed object property"
+ ::= { cucsComputeMbPowerStatsHistEntry 11 }
+
+cucsComputeMbPowerStatsHistInputCurrentMin OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbPowerStatsHist:inputCurrentMin
+ managed object property"
+ ::= { cucsComputeMbPowerStatsHistEntry 12 }
+
+cucsComputeMbPowerStatsHistInputVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbPowerStatsHist:inputVoltage
+ managed object property"
+ ::= { cucsComputeMbPowerStatsHistEntry 13 }
+
+cucsComputeMbPowerStatsHistInputVoltageAvg OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbPowerStatsHist:inputVoltageAvg
+ managed object property"
+ ::= { cucsComputeMbPowerStatsHistEntry 14 }
+
+cucsComputeMbPowerStatsHistInputVoltageMax OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbPowerStatsHist:inputVoltageMax
+ managed object property"
+ ::= { cucsComputeMbPowerStatsHistEntry 15 }
+
+cucsComputeMbPowerStatsHistInputVoltageMin OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbPowerStatsHist:inputVoltageMin
+ managed object property"
+ ::= { cucsComputeMbPowerStatsHistEntry 16 }
+
+cucsComputeMbPowerStatsHistMostRecent OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbPowerStatsHist:mostRecent
+ managed object property"
+ ::= { cucsComputeMbPowerStatsHistEntry 17 }
+
+cucsComputeMbPowerStatsHistSuspect OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbPowerStatsHist:suspect managed
+ object property"
+ ::= { cucsComputeMbPowerStatsHistEntry 18 }
+
+cucsComputeMbPowerStatsHistThresholded OBJECT-TYPE
+ SYNTAX CucsComputeMbPowerStatsHistThresholded
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbPowerStatsHist:thresholded
+ managed object property"
+ ::= { cucsComputeMbPowerStatsHistEntry 19 }
+
+cucsComputeMbPowerStatsHistTimeCollected OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbPowerStatsHist:timeCollected
+ managed object property"
+ ::= { cucsComputeMbPowerStatsHistEntry 20 }
+
+cucsComputeMbTempStatsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputeMbTempStatsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbTempStats managed object table"
+ ::= { cucsComputeObjects 16 }
+
+cucsComputeMbTempStatsEntry OBJECT-TYPE
+ SYNTAX CucsComputeMbTempStatsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputeMbTempStatsTable table."
+ INDEX { cucsComputeMbTempStatsInstanceId }
+ ::= { cucsComputeMbTempStatsTable 1 }
+
+CucsComputeMbTempStatsEntry ::= SEQUENCE {
+ cucsComputeMbTempStatsInstanceId CucsManagedObjectId,
+ cucsComputeMbTempStatsDn CucsManagedObjectDn,
+ cucsComputeMbTempStatsRn SnmpAdminString,
+ cucsComputeMbTempStatsFmTempSenIo INTEGER,
+ cucsComputeMbTempStatsFmTempSenIoAvg INTEGER,
+ cucsComputeMbTempStatsFmTempSenIoMax INTEGER,
+ cucsComputeMbTempStatsFmTempSenIoMin INTEGER,
+ cucsComputeMbTempStatsFmTempSenRear INTEGER,
+ cucsComputeMbTempStatsFmTempSenRearAvg INTEGER,
+ cucsComputeMbTempStatsFmTempSenRearL INTEGER,
+ cucsComputeMbTempStatsFmTempSenRearLAvg INTEGER,
+ cucsComputeMbTempStatsFmTempSenRearLMax INTEGER,
+ cucsComputeMbTempStatsFmTempSenRearLMin INTEGER,
+ cucsComputeMbTempStatsFmTempSenRearMax INTEGER,
+ cucsComputeMbTempStatsFmTempSenRearMin INTEGER,
+ cucsComputeMbTempStatsFmTempSenRearR INTEGER,
+ cucsComputeMbTempStatsFmTempSenRearRAvg INTEGER,
+ cucsComputeMbTempStatsFmTempSenRearRMax INTEGER,
+ cucsComputeMbTempStatsFmTempSenRearRMin INTEGER,
+ cucsComputeMbTempStatsIntervals Gauge32,
+ cucsComputeMbTempStatsSuspect TruthValue,
+ cucsComputeMbTempStatsThresholded CucsComputeMbTempStatsThresholded,
+ cucsComputeMbTempStatsTimeCollected DateAndTime,
+ cucsComputeMbTempStatsUpdate Gauge32
+}
+
+cucsComputeMbTempStatsInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputeMbTempStatsEntry 1 }
+
+cucsComputeMbTempStatsDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbTempStats:dn managed object property"
+ ::= { cucsComputeMbTempStatsEntry 2 }
+
+cucsComputeMbTempStatsRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbTempStats:rn managed object property"
+ ::= { cucsComputeMbTempStatsEntry 3 }
+
+cucsComputeMbTempStatsFmTempSenIo OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbTempStats:fmTempSenIo managed
+ object property"
+ ::= { cucsComputeMbTempStatsEntry 4 }
+
+cucsComputeMbTempStatsFmTempSenIoAvg OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbTempStats:fmTempSenIoAvg managed
+ object property"
+ ::= { cucsComputeMbTempStatsEntry 5 }
+
+cucsComputeMbTempStatsFmTempSenIoMax OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbTempStats:fmTempSenIoMax managed
+ object property"
+ ::= { cucsComputeMbTempStatsEntry 6 }
+
+cucsComputeMbTempStatsFmTempSenIoMin OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbTempStats:fmTempSenIoMin managed
+ object property"
+ ::= { cucsComputeMbTempStatsEntry 7 }
+
+cucsComputeMbTempStatsFmTempSenRear OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbTempStats:fmTempSenRear managed
+ object property"
+ ::= { cucsComputeMbTempStatsEntry 8 }
+
+cucsComputeMbTempStatsFmTempSenRearAvg OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbTempStats:fmTempSenRearAvg
+ managed object property"
+ ::= { cucsComputeMbTempStatsEntry 9 }
+
+cucsComputeMbTempStatsFmTempSenRearL OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbTempStats:fmTempSenRearL managed
+ object property"
+ ::= { cucsComputeMbTempStatsEntry 10 }
+
+cucsComputeMbTempStatsFmTempSenRearLAvg OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbTempStats:fmTempSenRearLAvg
+ managed object property"
+ ::= { cucsComputeMbTempStatsEntry 11 }
+
+cucsComputeMbTempStatsFmTempSenRearLMax OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbTempStats:fmTempSenRearLMax
+ managed object property"
+ ::= { cucsComputeMbTempStatsEntry 12 }
+
+cucsComputeMbTempStatsFmTempSenRearLMin OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbTempStats:fmTempSenRearLMin
+ managed object property"
+ ::= { cucsComputeMbTempStatsEntry 13 }
+
+cucsComputeMbTempStatsFmTempSenRearMax OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbTempStats:fmTempSenRearMax
+ managed object property"
+ ::= { cucsComputeMbTempStatsEntry 14 }
+
+cucsComputeMbTempStatsFmTempSenRearMin OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbTempStats:fmTempSenRearMin
+ managed object property"
+ ::= { cucsComputeMbTempStatsEntry 15 }
+
+cucsComputeMbTempStatsFmTempSenRearR OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbTempStats:fmTempSenRearR managed
+ object property"
+ ::= { cucsComputeMbTempStatsEntry 16 }
+
+cucsComputeMbTempStatsFmTempSenRearRAvg OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbTempStats:fmTempSenRearRAvg
+ managed object property"
+ ::= { cucsComputeMbTempStatsEntry 17 }
+
+cucsComputeMbTempStatsFmTempSenRearRMax OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbTempStats:fmTempSenRearRMax
+ managed object property"
+ ::= { cucsComputeMbTempStatsEntry 18 }
+
+cucsComputeMbTempStatsFmTempSenRearRMin OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbTempStats:fmTempSenRearRMin
+ managed object property"
+ ::= { cucsComputeMbTempStatsEntry 19 }
+
+cucsComputeMbTempStatsIntervals OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbTempStats:intervals managed object property"
+ ::= { cucsComputeMbTempStatsEntry 20 }
+
+cucsComputeMbTempStatsSuspect OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbTempStats:suspect managed object property"
+ ::= { cucsComputeMbTempStatsEntry 21 }
+
+cucsComputeMbTempStatsThresholded OBJECT-TYPE
+ SYNTAX CucsComputeMbTempStatsThresholded
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbTempStats:thresholded managed
+ object property"
+ ::= { cucsComputeMbTempStatsEntry 22 }
+
+cucsComputeMbTempStatsTimeCollected OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbTempStats:timeCollected managed
+ object property"
+ ::= { cucsComputeMbTempStatsEntry 23 }
+
+cucsComputeMbTempStatsUpdate OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbTempStats:update managed object property"
+ ::= { cucsComputeMbTempStatsEntry 24 }
+
+cucsComputeMbTempStatsHistTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputeMbTempStatsHistEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbTempStatsHist managed object table"
+ ::= { cucsComputeObjects 17 }
+
+cucsComputeMbTempStatsHistEntry OBJECT-TYPE
+ SYNTAX CucsComputeMbTempStatsHistEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputeMbTempStatsHistTable table."
+ INDEX { cucsComputeMbTempStatsHistInstanceId }
+ ::= { cucsComputeMbTempStatsHistTable 1 }
+
+CucsComputeMbTempStatsHistEntry ::= SEQUENCE {
+ cucsComputeMbTempStatsHistInstanceId CucsManagedObjectId,
+ cucsComputeMbTempStatsHistDn CucsManagedObjectDn,
+ cucsComputeMbTempStatsHistRn SnmpAdminString,
+ cucsComputeMbTempStatsHistFmTempSenIo INTEGER,
+ cucsComputeMbTempStatsHistFmTempSenIoAvg INTEGER,
+ cucsComputeMbTempStatsHistFmTempSenIoMax INTEGER,
+ cucsComputeMbTempStatsHistFmTempSenIoMin INTEGER,
+ cucsComputeMbTempStatsHistFmTempSenRear INTEGER,
+ cucsComputeMbTempStatsHistFmTempSenRearAvg INTEGER,
+ cucsComputeMbTempStatsHistFmTempSenRearL INTEGER,
+ cucsComputeMbTempStatsHistFmTempSenRearLAvg INTEGER,
+ cucsComputeMbTempStatsHistFmTempSenRearLMax INTEGER,
+ cucsComputeMbTempStatsHistFmTempSenRearLMin INTEGER,
+ cucsComputeMbTempStatsHistFmTempSenRearMax INTEGER,
+ cucsComputeMbTempStatsHistFmTempSenRearMin INTEGER,
+ cucsComputeMbTempStatsHistFmTempSenRearR INTEGER,
+ cucsComputeMbTempStatsHistFmTempSenRearRAvg INTEGER,
+ cucsComputeMbTempStatsHistFmTempSenRearRMax INTEGER,
+ cucsComputeMbTempStatsHistFmTempSenRearRMin INTEGER,
+ cucsComputeMbTempStatsHistId Unsigned64,
+ cucsComputeMbTempStatsHistMostRecent TruthValue,
+ cucsComputeMbTempStatsHistSuspect TruthValue,
+ cucsComputeMbTempStatsHistThresholded CucsComputeMbTempStatsHistThresholded,
+ cucsComputeMbTempStatsHistTimeCollected DateAndTime
+}
+
+cucsComputeMbTempStatsHistInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputeMbTempStatsHistEntry 1 }
+
+cucsComputeMbTempStatsHistDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbTempStatsHist:dn managed object property"
+ ::= { cucsComputeMbTempStatsHistEntry 2 }
+
+cucsComputeMbTempStatsHistRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbTempStatsHist:rn managed object property"
+ ::= { cucsComputeMbTempStatsHistEntry 3 }
+
+cucsComputeMbTempStatsHistFmTempSenIo OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbTempStatsHist:fmTempSenIo
+ managed object property"
+ ::= { cucsComputeMbTempStatsHistEntry 4 }
+
+cucsComputeMbTempStatsHistFmTempSenIoAvg OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbTempStatsHist:fmTempSenIoAvg
+ managed object property"
+ ::= { cucsComputeMbTempStatsHistEntry 5 }
+
+cucsComputeMbTempStatsHistFmTempSenIoMax OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbTempStatsHist:fmTempSenIoMax
+ managed object property"
+ ::= { cucsComputeMbTempStatsHistEntry 6 }
+
+cucsComputeMbTempStatsHistFmTempSenIoMin OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbTempStatsHist:fmTempSenIoMin
+ managed object property"
+ ::= { cucsComputeMbTempStatsHistEntry 7 }
+
+cucsComputeMbTempStatsHistFmTempSenRear OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbTempStatsHist:fmTempSenRear
+ managed object property"
+ ::= { cucsComputeMbTempStatsHistEntry 8 }
+
+cucsComputeMbTempStatsHistFmTempSenRearAvg OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbTempStatsHist:fmTempSenRearAvg
+ managed object property"
+ ::= { cucsComputeMbTempStatsHistEntry 9 }
+
+cucsComputeMbTempStatsHistFmTempSenRearL OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbTempStatsHist:fmTempSenRearL
+ managed object property"
+ ::= { cucsComputeMbTempStatsHistEntry 10 }
+
+cucsComputeMbTempStatsHistFmTempSenRearLAvg OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbTempStatsHist:fmTempSenRearLAvg
+ managed object property"
+ ::= { cucsComputeMbTempStatsHistEntry 11 }
+
+cucsComputeMbTempStatsHistFmTempSenRearLMax OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbTempStatsHist:fmTempSenRearLMax
+ managed object property"
+ ::= { cucsComputeMbTempStatsHistEntry 12 }
+
+cucsComputeMbTempStatsHistFmTempSenRearLMin OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbTempStatsHist:fmTempSenRearLMin
+ managed object property"
+ ::= { cucsComputeMbTempStatsHistEntry 13 }
+
+cucsComputeMbTempStatsHistFmTempSenRearMax OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbTempStatsHist:fmTempSenRearMax
+ managed object property"
+ ::= { cucsComputeMbTempStatsHistEntry 14 }
+
+cucsComputeMbTempStatsHistFmTempSenRearMin OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbTempStatsHist:fmTempSenRearMin
+ managed object property"
+ ::= { cucsComputeMbTempStatsHistEntry 15 }
+
+cucsComputeMbTempStatsHistFmTempSenRearR OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbTempStatsHist:fmTempSenRearR
+ managed object property"
+ ::= { cucsComputeMbTempStatsHistEntry 16 }
+
+cucsComputeMbTempStatsHistFmTempSenRearRAvg OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbTempStatsHist:fmTempSenRearRAvg
+ managed object property"
+ ::= { cucsComputeMbTempStatsHistEntry 17 }
+
+cucsComputeMbTempStatsHistFmTempSenRearRMax OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbTempStatsHist:fmTempSenRearRMax
+ managed object property"
+ ::= { cucsComputeMbTempStatsHistEntry 18 }
+
+cucsComputeMbTempStatsHistFmTempSenRearRMin OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbTempStatsHist:fmTempSenRearRMin
+ managed object property"
+ ::= { cucsComputeMbTempStatsHistEntry 19 }
+
+cucsComputeMbTempStatsHistId OBJECT-TYPE
+ SYNTAX Unsigned64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbTempStatsHist:id managed object property"
+ ::= { cucsComputeMbTempStatsHistEntry 20 }
+
+cucsComputeMbTempStatsHistMostRecent OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbTempStatsHist:mostRecent managed
+ object property"
+ ::= { cucsComputeMbTempStatsHistEntry 21 }
+
+cucsComputeMbTempStatsHistSuspect OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbTempStatsHist:suspect managed
+ object property"
+ ::= { cucsComputeMbTempStatsHistEntry 22 }
+
+cucsComputeMbTempStatsHistThresholded OBJECT-TYPE
+ SYNTAX CucsComputeMbTempStatsHistThresholded
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbTempStatsHist:thresholded
+ managed object property"
+ ::= { cucsComputeMbTempStatsHistEntry 23 }
+
+cucsComputeMbTempStatsHistTimeCollected OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MbTempStatsHist:timeCollected
+ managed object property"
+ ::= { cucsComputeMbTempStatsHistEntry 24 }
+
+cucsComputeMemoryConfigPolicyTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputeMemoryConfigPolicyEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MemoryConfigPolicy managed object table"
+ ::= { cucsComputeObjects 61 }
+
+cucsComputeMemoryConfigPolicyEntry OBJECT-TYPE
+ SYNTAX CucsComputeMemoryConfigPolicyEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputeMemoryConfigPolicyTable table."
+ INDEX { cucsComputeMemoryConfigPolicyInstanceId }
+ ::= { cucsComputeMemoryConfigPolicyTable 1 }
+
+CucsComputeMemoryConfigPolicyEntry ::= SEQUENCE {
+ cucsComputeMemoryConfigPolicyInstanceId CucsManagedObjectId,
+ cucsComputeMemoryConfigPolicyDn CucsManagedObjectDn,
+ cucsComputeMemoryConfigPolicyRn SnmpAdminString,
+ cucsComputeMemoryConfigPolicyBlackListing CucsComputeBlackListing,
+ cucsComputeMemoryConfigPolicyDescr SnmpAdminString,
+ cucsComputeMemoryConfigPolicyIntId SnmpAdminString,
+ cucsComputeMemoryConfigPolicyName SnmpAdminString,
+ cucsComputeMemoryConfigPolicyPolicyLevel Gauge32,
+ cucsComputeMemoryConfigPolicyPolicyOwner CucsPolicyPolicyOwner
+}
+
+cucsComputeMemoryConfigPolicyInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputeMemoryConfigPolicyEntry 1 }
+
+cucsComputeMemoryConfigPolicyDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MemoryConfigPolicy:dn managed object property"
+ ::= { cucsComputeMemoryConfigPolicyEntry 2 }
+
+cucsComputeMemoryConfigPolicyRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MemoryConfigPolicy:rn managed object property"
+ ::= { cucsComputeMemoryConfigPolicyEntry 3 }
+
+cucsComputeMemoryConfigPolicyBlackListing OBJECT-TYPE
+ SYNTAX CucsComputeBlackListing
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MemoryConfigPolicy:blackListing
+ managed object property"
+ ::= { cucsComputeMemoryConfigPolicyEntry 4 }
+
+cucsComputeMemoryConfigPolicyDescr OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MemoryConfigPolicy:descr managed
+ object property"
+ ::= { cucsComputeMemoryConfigPolicyEntry 5 }
+
+cucsComputeMemoryConfigPolicyIntId OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MemoryConfigPolicy:intId managed
+ object property"
+ ::= { cucsComputeMemoryConfigPolicyEntry 6 }
+
+cucsComputeMemoryConfigPolicyName OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MemoryConfigPolicy:name managed
+ object property"
+ ::= { cucsComputeMemoryConfigPolicyEntry 7 }
+
+cucsComputeMemoryConfigPolicyPolicyLevel OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MemoryConfigPolicy:policyLevel
+ managed object property"
+ ::= { cucsComputeMemoryConfigPolicyEntry 8 }
+
+cucsComputeMemoryConfigPolicyPolicyOwner OBJECT-TYPE
+ SYNTAX CucsPolicyPolicyOwner
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MemoryConfigPolicy:policyOwner
+ managed object property"
+ ::= { cucsComputeMemoryConfigPolicyEntry 9 }
+
+cucsComputeMemoryConfigurationTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputeMemoryConfigurationEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MemoryConfiguration managed object table"
+ ::= { cucsComputeObjects 62 }
+
+cucsComputeMemoryConfigurationEntry OBJECT-TYPE
+ SYNTAX CucsComputeMemoryConfigurationEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputeMemoryConfigurationTable table."
+ INDEX { cucsComputeMemoryConfigurationInstanceId }
+ ::= { cucsComputeMemoryConfigurationTable 1 }
+
+CucsComputeMemoryConfigurationEntry ::= SEQUENCE {
+ cucsComputeMemoryConfigurationInstanceId CucsManagedObjectId,
+ cucsComputeMemoryConfigurationDn CucsManagedObjectDn,
+ cucsComputeMemoryConfigurationRn SnmpAdminString,
+ cucsComputeMemoryConfigurationAdminMemoryState CucsComputeAdminMemoryState,
+ cucsComputeMemoryConfigurationBlackListing CucsComputeBlackListing
+}
+
+cucsComputeMemoryConfigurationInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputeMemoryConfigurationEntry 1 }
+
+cucsComputeMemoryConfigurationDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MemoryConfiguration:dn managed object property"
+ ::= { cucsComputeMemoryConfigurationEntry 2 }
+
+cucsComputeMemoryConfigurationRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MemoryConfiguration:rn managed object property"
+ ::= { cucsComputeMemoryConfigurationEntry 3 }
+
+cucsComputeMemoryConfigurationAdminMemoryState OBJECT-TYPE
+ SYNTAX CucsComputeAdminMemoryState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MemoryConfiguration:adminMemoryState
+ managed object property"
+ ::= { cucsComputeMemoryConfigurationEntry 4 }
+
+cucsComputeMemoryConfigurationBlackListing OBJECT-TYPE
+ SYNTAX CucsComputeBlackListing
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MemoryConfiguration:blackListing
+ managed object property"
+ ::= { cucsComputeMemoryConfigurationEntry 5 }
+
+cucsComputeMemoryUnitConstraintDefTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputeMemoryUnitConstraintDefEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MemoryUnitConstraintDef managed object table"
+ ::= { cucsComputeObjects 18 }
+
+cucsComputeMemoryUnitConstraintDefEntry OBJECT-TYPE
+ SYNTAX CucsComputeMemoryUnitConstraintDefEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputeMemoryUnitConstraintDefTable table."
+ INDEX { cucsComputeMemoryUnitConstraintDefInstanceId }
+ ::= { cucsComputeMemoryUnitConstraintDefTable 1 }
+
+CucsComputeMemoryUnitConstraintDefEntry ::= SEQUENCE {
+ cucsComputeMemoryUnitConstraintDefInstanceId CucsManagedObjectId,
+ cucsComputeMemoryUnitConstraintDefDn CucsManagedObjectDn,
+ cucsComputeMemoryUnitConstraintDefRn SnmpAdminString,
+ cucsComputeMemoryUnitConstraintDefDescr SnmpAdminString,
+ cucsComputeMemoryUnitConstraintDefIntId SnmpAdminString,
+ cucsComputeMemoryUnitConstraintDefName SnmpAdminString,
+ cucsComputeMemoryUnitConstraintDefType CucsComputeMemoryUnitConstraintType,
+ cucsComputeMemoryUnitConstraintDefRevisionModifier SnmpAdminString,
+ cucsComputeMemoryUnitConstraintDefPolicyLevel Gauge32,
+ cucsComputeMemoryUnitConstraintDefPolicyOwner CucsPolicyPolicyOwner
+}
+
+cucsComputeMemoryUnitConstraintDefInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputeMemoryUnitConstraintDefEntry 1 }
+
+cucsComputeMemoryUnitConstraintDefDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MemoryUnitConstraintDef:dn managed
+ object property"
+ ::= { cucsComputeMemoryUnitConstraintDefEntry 2 }
+
+cucsComputeMemoryUnitConstraintDefRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MemoryUnitConstraintDef:rn managed
+ object property"
+ ::= { cucsComputeMemoryUnitConstraintDefEntry 3 }
+
+cucsComputeMemoryUnitConstraintDefDescr OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MemoryUnitConstraintDef:descr
+ managed object property"
+ ::= { cucsComputeMemoryUnitConstraintDefEntry 4 }
+
+cucsComputeMemoryUnitConstraintDefIntId OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MemoryUnitConstraintDef:intId
+ managed object property"
+ ::= { cucsComputeMemoryUnitConstraintDefEntry 5 }
+
+cucsComputeMemoryUnitConstraintDefName OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MemoryUnitConstraintDef:name
+ managed object property"
+ ::= { cucsComputeMemoryUnitConstraintDefEntry 6 }
+
+cucsComputeMemoryUnitConstraintDefType OBJECT-TYPE
+ SYNTAX CucsComputeMemoryUnitConstraintType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MemoryUnitConstraintDef:type
+ managed object property"
+ ::= { cucsComputeMemoryUnitConstraintDefEntry 7 }
+
+cucsComputeMemoryUnitConstraintDefRevisionModifier OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MemoryUnitConstraintDef:revisionModifier
+ managed object property"
+ ::= { cucsComputeMemoryUnitConstraintDefEntry 8 }
+
+cucsComputeMemoryUnitConstraintDefPolicyLevel OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MemoryUnitConstraintDef:policyLevel
+ managed object property"
+ ::= { cucsComputeMemoryUnitConstraintDefEntry 9 }
+
+cucsComputeMemoryUnitConstraintDefPolicyOwner OBJECT-TYPE
+ SYNTAX CucsPolicyPolicyOwner
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:MemoryUnitConstraintDef:policyOwner
+ managed object property"
+ ::= { cucsComputeMemoryUnitConstraintDefEntry 10 }
+
+cucsComputePCIeFatalCompletionStatsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputePCIeFatalCompletionStatsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalCompletionStats managed object table"
+ ::= { cucsComputeObjects 19 }
+
+cucsComputePCIeFatalCompletionStatsEntry OBJECT-TYPE
+ SYNTAX CucsComputePCIeFatalCompletionStatsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputePCIeFatalCompletionStatsTable table."
+ INDEX { cucsComputePCIeFatalCompletionStatsInstanceId }
+ ::= { cucsComputePCIeFatalCompletionStatsTable 1 }
+
+CucsComputePCIeFatalCompletionStatsEntry ::= SEQUENCE {
+ cucsComputePCIeFatalCompletionStatsInstanceId CucsManagedObjectId,
+ cucsComputePCIeFatalCompletionStatsDn CucsManagedObjectDn,
+ cucsComputePCIeFatalCompletionStatsRn SnmpAdminString,
+ cucsComputePCIeFatalCompletionStatsAbortErrors Counter32,
+ cucsComputePCIeFatalCompletionStatsAbortErrors15Min Gauge32,
+ cucsComputePCIeFatalCompletionStatsAbortErrors15MinH Gauge32,
+ cucsComputePCIeFatalCompletionStatsAbortErrors1Day Gauge32,
+ cucsComputePCIeFatalCompletionStatsAbortErrors1DayH Gauge32,
+ cucsComputePCIeFatalCompletionStatsAbortErrors1Hour Gauge32,
+ cucsComputePCIeFatalCompletionStatsAbortErrors1HourH Gauge32,
+ cucsComputePCIeFatalCompletionStatsAbortErrors1Week Gauge32,
+ cucsComputePCIeFatalCompletionStatsAbortErrors1WeekH Gauge32,
+ cucsComputePCIeFatalCompletionStatsTimeoutErrors Counter32,
+ cucsComputePCIeFatalCompletionStatsTimeoutErrors15Min Gauge32,
+ cucsComputePCIeFatalCompletionStatsTimeoutErrors15MinH Gauge32,
+ cucsComputePCIeFatalCompletionStatsTimeoutErrors1Day Gauge32,
+ cucsComputePCIeFatalCompletionStatsTimeoutErrors1DayH Gauge32,
+ cucsComputePCIeFatalCompletionStatsTimeoutErrors1Hour Gauge32,
+ cucsComputePCIeFatalCompletionStatsTimeoutErrors1HourH Gauge32,
+ cucsComputePCIeFatalCompletionStatsTimeoutErrors1Week Gauge32,
+ cucsComputePCIeFatalCompletionStatsTimeoutErrors1WeekH Gauge32,
+ cucsComputePCIeFatalCompletionStatsIntervals Gauge32,
+ cucsComputePCIeFatalCompletionStatsSuspect TruthValue,
+ cucsComputePCIeFatalCompletionStatsThresholded CucsComputePCIeFatalCompletionStatsThresholded,
+ cucsComputePCIeFatalCompletionStatsTimeCollected DateAndTime,
+ cucsComputePCIeFatalCompletionStatsUnexpectedErrors Counter32,
+ cucsComputePCIeFatalCompletionStatsUnexpectedErrors15Min Gauge32,
+ cucsComputePCIeFatalCompletionStatsUnexpectedErrors15MinH Gauge32,
+ cucsComputePCIeFatalCompletionStatsUnexpectedErrors1Day Gauge32,
+ cucsComputePCIeFatalCompletionStatsUnexpectedErrors1DayH Gauge32,
+ cucsComputePCIeFatalCompletionStatsUnexpectedErrors1Hour Gauge32,
+ cucsComputePCIeFatalCompletionStatsUnexpectedErrors1HourH Gauge32,
+ cucsComputePCIeFatalCompletionStatsUnexpectedErrors1Week Gauge32,
+ cucsComputePCIeFatalCompletionStatsUnexpectedErrors1WeekH Gauge32,
+ cucsComputePCIeFatalCompletionStatsUpdate Gauge32,
+ cucsComputePCIeFatalCompletionStatsAbortErrors2Weeks Gauge32,
+ cucsComputePCIeFatalCompletionStatsAbortErrors2WeeksH Gauge32,
+ cucsComputePCIeFatalCompletionStatsTimeoutErrors2Weeks Gauge32,
+ cucsComputePCIeFatalCompletionStatsTimeoutErrors2WeeksH Gauge32,
+ cucsComputePCIeFatalCompletionStatsUnexpectedErrors2Weeks Gauge32,
+ cucsComputePCIeFatalCompletionStatsUnexpectedErrors2WeeksH Gauge32
+}
+
+cucsComputePCIeFatalCompletionStatsInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputePCIeFatalCompletionStatsEntry 1 }
+
+cucsComputePCIeFatalCompletionStatsDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalCompletionStats:dn
+ managed object property"
+ ::= { cucsComputePCIeFatalCompletionStatsEntry 2 }
+
+cucsComputePCIeFatalCompletionStatsRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalCompletionStats:rn
+ managed object property"
+ ::= { cucsComputePCIeFatalCompletionStatsEntry 3 }
+
+cucsComputePCIeFatalCompletionStatsAbortErrors OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalCompletionStats:AbortErrors
+ managed object property"
+ ::= { cucsComputePCIeFatalCompletionStatsEntry 4 }
+
+cucsComputePCIeFatalCompletionStatsAbortErrors15Min OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalCompletionStats:AbortErrors15Min
+ managed object property"
+ ::= { cucsComputePCIeFatalCompletionStatsEntry 5 }
+
+cucsComputePCIeFatalCompletionStatsAbortErrors15MinH OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalCompletionStats:AbortErrors15MinH
+ managed object property"
+ ::= { cucsComputePCIeFatalCompletionStatsEntry 6 }
+
+cucsComputePCIeFatalCompletionStatsAbortErrors1Day OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalCompletionStats:AbortErrors1Day
+ managed object property"
+ ::= { cucsComputePCIeFatalCompletionStatsEntry 7 }
+
+cucsComputePCIeFatalCompletionStatsAbortErrors1DayH OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalCompletionStats:AbortErrors1DayH
+ managed object property"
+ ::= { cucsComputePCIeFatalCompletionStatsEntry 8 }
+
+cucsComputePCIeFatalCompletionStatsAbortErrors1Hour OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalCompletionStats:AbortErrors1Hour
+ managed object property"
+ ::= { cucsComputePCIeFatalCompletionStatsEntry 9 }
+
+cucsComputePCIeFatalCompletionStatsAbortErrors1HourH OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalCompletionStats:AbortErrors1HourH
+ managed object property"
+ ::= { cucsComputePCIeFatalCompletionStatsEntry 10 }
+
+cucsComputePCIeFatalCompletionStatsAbortErrors1Week OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalCompletionStats:AbortErrors1Week
+ managed object property"
+ ::= { cucsComputePCIeFatalCompletionStatsEntry 11 }
+
+cucsComputePCIeFatalCompletionStatsAbortErrors1WeekH OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalCompletionStats:AbortErrors1WeekH
+ managed object property"
+ ::= { cucsComputePCIeFatalCompletionStatsEntry 12 }
+
+cucsComputePCIeFatalCompletionStatsTimeoutErrors OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalCompletionStats:TimeoutErrors
+ managed object property"
+ ::= { cucsComputePCIeFatalCompletionStatsEntry 13 }
+
+cucsComputePCIeFatalCompletionStatsTimeoutErrors15Min OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalCompletionStats:TimeoutErrors15Min
+ managed object property"
+ ::= { cucsComputePCIeFatalCompletionStatsEntry 14 }
+
+cucsComputePCIeFatalCompletionStatsTimeoutErrors15MinH OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalCompletionStats:TimeoutErrors15MinH
+ managed object property"
+ ::= { cucsComputePCIeFatalCompletionStatsEntry 15 }
+
+cucsComputePCIeFatalCompletionStatsTimeoutErrors1Day OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalCompletionStats:TimeoutErrors1Day
+ managed object property"
+ ::= { cucsComputePCIeFatalCompletionStatsEntry 16 }
+
+cucsComputePCIeFatalCompletionStatsTimeoutErrors1DayH OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalCompletionStats:TimeoutErrors1DayH
+ managed object property"
+ ::= { cucsComputePCIeFatalCompletionStatsEntry 17 }
+
+cucsComputePCIeFatalCompletionStatsTimeoutErrors1Hour OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalCompletionStats:TimeoutErrors1Hour
+ managed object property"
+ ::= { cucsComputePCIeFatalCompletionStatsEntry 18 }
+
+cucsComputePCIeFatalCompletionStatsTimeoutErrors1HourH OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalCompletionStats:TimeoutErrors1HourH
+ managed object property"
+ ::= { cucsComputePCIeFatalCompletionStatsEntry 19 }
+
+cucsComputePCIeFatalCompletionStatsTimeoutErrors1Week OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalCompletionStats:TimeoutErrors1Week
+ managed object property"
+ ::= { cucsComputePCIeFatalCompletionStatsEntry 20 }
+
+cucsComputePCIeFatalCompletionStatsTimeoutErrors1WeekH OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalCompletionStats:TimeoutErrors1WeekH
+ managed object property"
+ ::= { cucsComputePCIeFatalCompletionStatsEntry 21 }
+
+cucsComputePCIeFatalCompletionStatsIntervals OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalCompletionStats:intervals
+ managed object property"
+ ::= { cucsComputePCIeFatalCompletionStatsEntry 22 }
+
+cucsComputePCIeFatalCompletionStatsSuspect OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalCompletionStats:suspect
+ managed object property"
+ ::= { cucsComputePCIeFatalCompletionStatsEntry 23 }
+
+cucsComputePCIeFatalCompletionStatsThresholded OBJECT-TYPE
+ SYNTAX CucsComputePCIeFatalCompletionStatsThresholded
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalCompletionStats:thresholded
+ managed object property"
+ ::= { cucsComputePCIeFatalCompletionStatsEntry 24 }
+
+cucsComputePCIeFatalCompletionStatsTimeCollected OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalCompletionStats:timeCollected
+ managed object property"
+ ::= { cucsComputePCIeFatalCompletionStatsEntry 25 }
+
+cucsComputePCIeFatalCompletionStatsUnexpectedErrors OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalCompletionStats:unexpectedErrors
+ managed object property"
+ ::= { cucsComputePCIeFatalCompletionStatsEntry 26 }
+
+cucsComputePCIeFatalCompletionStatsUnexpectedErrors15Min OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalCompletionStats:unexpectedErrors15Min
+ managed object property"
+ ::= { cucsComputePCIeFatalCompletionStatsEntry 27 }
+
+cucsComputePCIeFatalCompletionStatsUnexpectedErrors15MinH OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalCompletionStats:unexpectedErrors15MinH
+ managed object property"
+ ::= { cucsComputePCIeFatalCompletionStatsEntry 28 }
+
+cucsComputePCIeFatalCompletionStatsUnexpectedErrors1Day OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalCompletionStats:unexpectedErrors1Day
+ managed object property"
+ ::= { cucsComputePCIeFatalCompletionStatsEntry 29 }
+
+cucsComputePCIeFatalCompletionStatsUnexpectedErrors1DayH OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalCompletionStats:unexpectedErrors1DayH
+ managed object property"
+ ::= { cucsComputePCIeFatalCompletionStatsEntry 30 }
+
+cucsComputePCIeFatalCompletionStatsUnexpectedErrors1Hour OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalCompletionStats:unexpectedErrors1Hour
+ managed object property"
+ ::= { cucsComputePCIeFatalCompletionStatsEntry 31 }
+
+cucsComputePCIeFatalCompletionStatsUnexpectedErrors1HourH OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalCompletionStats:unexpectedErrors1HourH
+ managed object property"
+ ::= { cucsComputePCIeFatalCompletionStatsEntry 32 }
+
+cucsComputePCIeFatalCompletionStatsUnexpectedErrors1Week OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalCompletionStats:unexpectedErrors1Week
+ managed object property"
+ ::= { cucsComputePCIeFatalCompletionStatsEntry 33 }
+
+cucsComputePCIeFatalCompletionStatsUnexpectedErrors1WeekH OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalCompletionStats:unexpectedErrors1WeekH
+ managed object property"
+ ::= { cucsComputePCIeFatalCompletionStatsEntry 34 }
+
+cucsComputePCIeFatalCompletionStatsUpdate OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalCompletionStats:update
+ managed object property"
+ ::= { cucsComputePCIeFatalCompletionStatsEntry 35 }
+
+cucsComputePCIeFatalCompletionStatsAbortErrors2Weeks OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalCompletionStats:AbortErrors2Weeks
+ managed object property"
+ ::= { cucsComputePCIeFatalCompletionStatsEntry 36 }
+
+cucsComputePCIeFatalCompletionStatsAbortErrors2WeeksH OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalCompletionStats:AbortErrors2WeeksH
+ managed object property"
+ ::= { cucsComputePCIeFatalCompletionStatsEntry 37 }
+
+cucsComputePCIeFatalCompletionStatsTimeoutErrors2Weeks OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalCompletionStats:TimeoutErrors2Weeks
+ managed object property"
+ ::= { cucsComputePCIeFatalCompletionStatsEntry 38 }
+
+cucsComputePCIeFatalCompletionStatsTimeoutErrors2WeeksH OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalCompletionStats:TimeoutErrors2WeeksH
+ managed object property"
+ ::= { cucsComputePCIeFatalCompletionStatsEntry 39 }
+
+cucsComputePCIeFatalCompletionStatsUnexpectedErrors2Weeks OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalCompletionStats:unexpectedErrors2Weeks
+ managed object property"
+ ::= { cucsComputePCIeFatalCompletionStatsEntry 40 }
+
+cucsComputePCIeFatalCompletionStatsUnexpectedErrors2WeeksH OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalCompletionStats:unexpectedErrors2Weeks
+ H managed object property"
+ ::= { cucsComputePCIeFatalCompletionStatsEntry 41 }
+
+cucsComputePCIeFatalProtocolStatsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputePCIeFatalProtocolStatsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalProtocolStats managed object table"
+ ::= { cucsComputeObjects 20 }
+
+cucsComputePCIeFatalProtocolStatsEntry OBJECT-TYPE
+ SYNTAX CucsComputePCIeFatalProtocolStatsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputePCIeFatalProtocolStatsTable table."
+ INDEX { cucsComputePCIeFatalProtocolStatsInstanceId }
+ ::= { cucsComputePCIeFatalProtocolStatsTable 1 }
+
+CucsComputePCIeFatalProtocolStatsEntry ::= SEQUENCE {
+ cucsComputePCIeFatalProtocolStatsInstanceId CucsManagedObjectId,
+ cucsComputePCIeFatalProtocolStatsDn CucsManagedObjectDn,
+ cucsComputePCIeFatalProtocolStatsRn SnmpAdminString,
+ cucsComputePCIeFatalProtocolStatsDllpErrors Counter32,
+ cucsComputePCIeFatalProtocolStatsDllpErrors15Min Gauge32,
+ cucsComputePCIeFatalProtocolStatsDllpErrors15MinH Gauge32,
+ cucsComputePCIeFatalProtocolStatsDllpErrors1Day Gauge32,
+ cucsComputePCIeFatalProtocolStatsDllpErrors1DayH Gauge32,
+ cucsComputePCIeFatalProtocolStatsDllpErrors1Hour Gauge32,
+ cucsComputePCIeFatalProtocolStatsDllpErrors1HourH Gauge32,
+ cucsComputePCIeFatalProtocolStatsDllpErrors1Week Gauge32,
+ cucsComputePCIeFatalProtocolStatsDllpErrors1WeekH Gauge32,
+ cucsComputePCIeFatalProtocolStatsFlowControlErrors Counter32,
+ cucsComputePCIeFatalProtocolStatsFlowControlErrors15Min Gauge32,
+ cucsComputePCIeFatalProtocolStatsFlowControlErrors15MinH Gauge32,
+ cucsComputePCIeFatalProtocolStatsFlowControlErrors1Day Gauge32,
+ cucsComputePCIeFatalProtocolStatsFlowControlErrors1DayH Gauge32,
+ cucsComputePCIeFatalProtocolStatsFlowControlErrors1Hour Gauge32,
+ cucsComputePCIeFatalProtocolStatsFlowControlErrors1HourH Gauge32,
+ cucsComputePCIeFatalProtocolStatsFlowControlErrors1Week Gauge32,
+ cucsComputePCIeFatalProtocolStatsFlowControlErrors1WeekH Gauge32,
+ cucsComputePCIeFatalProtocolStatsIntervals Gauge32,
+ cucsComputePCIeFatalProtocolStatsSuspect TruthValue,
+ cucsComputePCIeFatalProtocolStatsThresholded CucsComputePCIeFatalProtocolStatsThresholded,
+ cucsComputePCIeFatalProtocolStatsTimeCollected DateAndTime,
+ cucsComputePCIeFatalProtocolStatsUpdate Gauge32,
+ cucsComputePCIeFatalProtocolStatsDllpErrors2Weeks Gauge32,
+ cucsComputePCIeFatalProtocolStatsDllpErrors2WeeksH Gauge32,
+ cucsComputePCIeFatalProtocolStatsFlowControlErrors2Weeks Gauge32,
+ cucsComputePCIeFatalProtocolStatsFlowControlErrors2WeeksH Gauge32
+}
+
+cucsComputePCIeFatalProtocolStatsInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputePCIeFatalProtocolStatsEntry 1 }
+
+cucsComputePCIeFatalProtocolStatsDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalProtocolStats:dn managed
+ object property"
+ ::= { cucsComputePCIeFatalProtocolStatsEntry 2 }
+
+cucsComputePCIeFatalProtocolStatsRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalProtocolStats:rn managed
+ object property"
+ ::= { cucsComputePCIeFatalProtocolStatsEntry 3 }
+
+cucsComputePCIeFatalProtocolStatsDllpErrors OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalProtocolStats:dllpErrors
+ managed object property"
+ ::= { cucsComputePCIeFatalProtocolStatsEntry 4 }
+
+cucsComputePCIeFatalProtocolStatsDllpErrors15Min OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalProtocolStats:dllpErrors15Min
+ managed object property"
+ ::= { cucsComputePCIeFatalProtocolStatsEntry 5 }
+
+cucsComputePCIeFatalProtocolStatsDllpErrors15MinH OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalProtocolStats:dllpErrors15MinH
+ managed object property"
+ ::= { cucsComputePCIeFatalProtocolStatsEntry 6 }
+
+cucsComputePCIeFatalProtocolStatsDllpErrors1Day OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalProtocolStats:dllpErrors1Day
+ managed object property"
+ ::= { cucsComputePCIeFatalProtocolStatsEntry 7 }
+
+cucsComputePCIeFatalProtocolStatsDllpErrors1DayH OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalProtocolStats:dllpErrors1DayH
+ managed object property"
+ ::= { cucsComputePCIeFatalProtocolStatsEntry 8 }
+
+cucsComputePCIeFatalProtocolStatsDllpErrors1Hour OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalProtocolStats:dllpErrors1Hour
+ managed object property"
+ ::= { cucsComputePCIeFatalProtocolStatsEntry 9 }
+
+cucsComputePCIeFatalProtocolStatsDllpErrors1HourH OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalProtocolStats:dllpErrors1HourH
+ managed object property"
+ ::= { cucsComputePCIeFatalProtocolStatsEntry 10 }
+
+cucsComputePCIeFatalProtocolStatsDllpErrors1Week OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalProtocolStats:dllpErrors1Week
+ managed object property"
+ ::= { cucsComputePCIeFatalProtocolStatsEntry 11 }
+
+cucsComputePCIeFatalProtocolStatsDllpErrors1WeekH OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalProtocolStats:dllpErrors1WeekH
+ managed object property"
+ ::= { cucsComputePCIeFatalProtocolStatsEntry 12 }
+
+cucsComputePCIeFatalProtocolStatsFlowControlErrors OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalProtocolStats:flowControlErrors
+ managed object property"
+ ::= { cucsComputePCIeFatalProtocolStatsEntry 13 }
+
+cucsComputePCIeFatalProtocolStatsFlowControlErrors15Min OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalProtocolStats:flowControlErrors15Min
+ managed object property"
+ ::= { cucsComputePCIeFatalProtocolStatsEntry 14 }
+
+cucsComputePCIeFatalProtocolStatsFlowControlErrors15MinH OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalProtocolStats:flowControlErrors15MinH
+ managed object property"
+ ::= { cucsComputePCIeFatalProtocolStatsEntry 15 }
+
+cucsComputePCIeFatalProtocolStatsFlowControlErrors1Day OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalProtocolStats:flowControlErrors1Day
+ managed object property"
+ ::= { cucsComputePCIeFatalProtocolStatsEntry 16 }
+
+cucsComputePCIeFatalProtocolStatsFlowControlErrors1DayH OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalProtocolStats:flowControlErrors1DayH
+ managed object property"
+ ::= { cucsComputePCIeFatalProtocolStatsEntry 17 }
+
+cucsComputePCIeFatalProtocolStatsFlowControlErrors1Hour OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalProtocolStats:flowControlErrors1Hour
+ managed object property"
+ ::= { cucsComputePCIeFatalProtocolStatsEntry 18 }
+
+cucsComputePCIeFatalProtocolStatsFlowControlErrors1HourH OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalProtocolStats:flowControlErrors1HourH
+ managed object property"
+ ::= { cucsComputePCIeFatalProtocolStatsEntry 19 }
+
+cucsComputePCIeFatalProtocolStatsFlowControlErrors1Week OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalProtocolStats:flowControlErrors1Week
+ managed object property"
+ ::= { cucsComputePCIeFatalProtocolStatsEntry 20 }
+
+cucsComputePCIeFatalProtocolStatsFlowControlErrors1WeekH OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalProtocolStats:flowControlErrors1WeekH
+ managed object property"
+ ::= { cucsComputePCIeFatalProtocolStatsEntry 21 }
+
+cucsComputePCIeFatalProtocolStatsIntervals OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalProtocolStats:intervals
+ managed object property"
+ ::= { cucsComputePCIeFatalProtocolStatsEntry 22 }
+
+cucsComputePCIeFatalProtocolStatsSuspect OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalProtocolStats:suspect
+ managed object property"
+ ::= { cucsComputePCIeFatalProtocolStatsEntry 23 }
+
+cucsComputePCIeFatalProtocolStatsThresholded OBJECT-TYPE
+ SYNTAX CucsComputePCIeFatalProtocolStatsThresholded
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalProtocolStats:thresholded
+ managed object property"
+ ::= { cucsComputePCIeFatalProtocolStatsEntry 24 }
+
+cucsComputePCIeFatalProtocolStatsTimeCollected OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalProtocolStats:timeCollected
+ managed object property"
+ ::= { cucsComputePCIeFatalProtocolStatsEntry 25 }
+
+cucsComputePCIeFatalProtocolStatsUpdate OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalProtocolStats:update
+ managed object property"
+ ::= { cucsComputePCIeFatalProtocolStatsEntry 26 }
+
+cucsComputePCIeFatalProtocolStatsDllpErrors2Weeks OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalProtocolStats:dllpErrors2Weeks
+ managed object property"
+ ::= { cucsComputePCIeFatalProtocolStatsEntry 27 }
+
+cucsComputePCIeFatalProtocolStatsDllpErrors2WeeksH OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalProtocolStats:dllpErrors2WeeksH
+ managed object property"
+ ::= { cucsComputePCIeFatalProtocolStatsEntry 28 }
+
+cucsComputePCIeFatalProtocolStatsFlowControlErrors2Weeks OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalProtocolStats:flowControlErrors2Weeks
+ managed object property"
+ ::= { cucsComputePCIeFatalProtocolStatsEntry 29 }
+
+cucsComputePCIeFatalProtocolStatsFlowControlErrors2WeeksH OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalProtocolStats:flowControlErrors2WeeksH
+ managed object property"
+ ::= { cucsComputePCIeFatalProtocolStatsEntry 30 }
+
+cucsComputePCIeFatalReceiveStatsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputePCIeFatalReceiveStatsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalReceiveStats managed object table"
+ ::= { cucsComputeObjects 21 }
+
+cucsComputePCIeFatalReceiveStatsEntry OBJECT-TYPE
+ SYNTAX CucsComputePCIeFatalReceiveStatsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputePCIeFatalReceiveStatsTable table."
+ INDEX { cucsComputePCIeFatalReceiveStatsInstanceId }
+ ::= { cucsComputePCIeFatalReceiveStatsTable 1 }
+
+CucsComputePCIeFatalReceiveStatsEntry ::= SEQUENCE {
+ cucsComputePCIeFatalReceiveStatsInstanceId CucsManagedObjectId,
+ cucsComputePCIeFatalReceiveStatsDn CucsManagedObjectDn,
+ cucsComputePCIeFatalReceiveStatsRn SnmpAdminString,
+ cucsComputePCIeFatalReceiveStatsBufferOverflowErrors Counter32,
+ cucsComputePCIeFatalReceiveStatsBufferOverflowErrors15Min Gauge32,
+ cucsComputePCIeFatalReceiveStatsBufferOverflowErrors15MinH Gauge32,
+ cucsComputePCIeFatalReceiveStatsBufferOverflowErrors1Day Gauge32,
+ cucsComputePCIeFatalReceiveStatsBufferOverflowErrors1DayH Gauge32,
+ cucsComputePCIeFatalReceiveStatsBufferOverflowErrors1Hour Gauge32,
+ cucsComputePCIeFatalReceiveStatsBufferOverflowErrors1HourH Gauge32,
+ cucsComputePCIeFatalReceiveStatsBufferOverflowErrors1Week Gauge32,
+ cucsComputePCIeFatalReceiveStatsBufferOverflowErrors1WeekH Gauge32,
+ cucsComputePCIeFatalReceiveStatsErrFatalErrors Counter32,
+ cucsComputePCIeFatalReceiveStatsErrFatalErrors15Min Gauge32,
+ cucsComputePCIeFatalReceiveStatsErrFatalErrors15MinH Gauge32,
+ cucsComputePCIeFatalReceiveStatsErrFatalErrors1Day Gauge32,
+ cucsComputePCIeFatalReceiveStatsErrFatalErrors1DayH Gauge32,
+ cucsComputePCIeFatalReceiveStatsErrFatalErrors1Hour Gauge32,
+ cucsComputePCIeFatalReceiveStatsErrFatalErrors1HourH Gauge32,
+ cucsComputePCIeFatalReceiveStatsErrFatalErrors1Week Gauge32,
+ cucsComputePCIeFatalReceiveStatsErrFatalErrors1WeekH Gauge32,
+ cucsComputePCIeFatalReceiveStatsErrNonFatalErrors Counter32,
+ cucsComputePCIeFatalReceiveStatsErrNonFatalErrors15Min Gauge32,
+ cucsComputePCIeFatalReceiveStatsErrNonFatalErrors15MinH Gauge32,
+ cucsComputePCIeFatalReceiveStatsErrNonFatalErrors1Day Gauge32,
+ cucsComputePCIeFatalReceiveStatsErrNonFatalErrors1DayH Gauge32,
+ cucsComputePCIeFatalReceiveStatsErrNonFatalErrors1Hour Gauge32,
+ cucsComputePCIeFatalReceiveStatsErrNonFatalErrors1HourH Gauge32,
+ cucsComputePCIeFatalReceiveStatsErrNonFatalErrors1Week Gauge32,
+ cucsComputePCIeFatalReceiveStatsErrNonFatalErrors1WeekH Gauge32,
+ cucsComputePCIeFatalReceiveStatsIntervals Gauge32,
+ cucsComputePCIeFatalReceiveStatsSuspect TruthValue,
+ cucsComputePCIeFatalReceiveStatsThresholded CucsComputePCIeFatalReceiveStatsThresholded,
+ cucsComputePCIeFatalReceiveStatsTimeCollected DateAndTime,
+ cucsComputePCIeFatalReceiveStatsUnsupportedRequestErrors Counter32,
+ cucsComputePCIeFatalReceiveStatsUnsupportedRequestErrors15Min Gauge32,
+ cucsComputePCIeFatalReceiveStatsUnsupportedRequestErrors15MinH Gauge32,
+ cucsComputePCIeFatalReceiveStatsUnsupportedRequestErrors1Day Gauge32,
+ cucsComputePCIeFatalReceiveStatsUnsupportedRequestErrors1DayH Gauge32,
+ cucsComputePCIeFatalReceiveStatsUnsupportedRequestErrors1Hour Gauge32,
+ cucsComputePCIeFatalReceiveStatsUnsupportedRequestErrors1HourH Gauge32,
+ cucsComputePCIeFatalReceiveStatsUnsupportedRequestErrors1Week Gauge32,
+ cucsComputePCIeFatalReceiveStatsUnsupportedRequestErrors1WeekH Gauge32,
+ cucsComputePCIeFatalReceiveStatsUpdate Gauge32,
+ cucsComputePCIeFatalReceiveStatsBufferOverflowErrors2Weeks Gauge32,
+ cucsComputePCIeFatalReceiveStatsBufferOverflowErrors2WeeksH Gauge32,
+ cucsComputePCIeFatalReceiveStatsErrFatalErrors2Weeks Gauge32,
+ cucsComputePCIeFatalReceiveStatsErrFatalErrors2WeeksH Gauge32,
+ cucsComputePCIeFatalReceiveStatsErrNonFatalErrors2Weeks Gauge32,
+ cucsComputePCIeFatalReceiveStatsErrNonFatalErrors2WeeksH Gauge32,
+ cucsComputePCIeFatalReceiveStatsUnsupportedRequestErrors2Weeks Gauge32,
+ cucsComputePCIeFatalReceiveStatsUnsupportedRequestErrors2WeeksH Gauge32
+}
+
+cucsComputePCIeFatalReceiveStatsInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputePCIeFatalReceiveStatsEntry 1 }
+
+cucsComputePCIeFatalReceiveStatsDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalReceiveStats:dn managed
+ object property"
+ ::= { cucsComputePCIeFatalReceiveStatsEntry 2 }
+
+cucsComputePCIeFatalReceiveStatsRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalReceiveStats:rn managed
+ object property"
+ ::= { cucsComputePCIeFatalReceiveStatsEntry 3 }
+
+cucsComputePCIeFatalReceiveStatsBufferOverflowErrors OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalReceiveStats:bufferOverflowErrors
+ managed object property"
+ ::= { cucsComputePCIeFatalReceiveStatsEntry 4 }
+
+cucsComputePCIeFatalReceiveStatsBufferOverflowErrors15Min OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalReceiveStats:bufferOverflowErrors15Min
+ managed object property"
+ ::= { cucsComputePCIeFatalReceiveStatsEntry 5 }
+
+cucsComputePCIeFatalReceiveStatsBufferOverflowErrors15MinH OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalReceiveStats:bufferOverflowErrors15Min
+ H managed object property"
+ ::= { cucsComputePCIeFatalReceiveStatsEntry 6 }
+
+cucsComputePCIeFatalReceiveStatsBufferOverflowErrors1Day OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalReceiveStats:bufferOverflowErrors1Day
+ managed object property"
+ ::= { cucsComputePCIeFatalReceiveStatsEntry 7 }
+
+cucsComputePCIeFatalReceiveStatsBufferOverflowErrors1DayH OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalReceiveStats:bufferOverflowErrors1DayH
+ managed object property"
+ ::= { cucsComputePCIeFatalReceiveStatsEntry 8 }
+
+cucsComputePCIeFatalReceiveStatsBufferOverflowErrors1Hour OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalReceiveStats:bufferOverflowErrors1Hour
+ managed object property"
+ ::= { cucsComputePCIeFatalReceiveStatsEntry 9 }
+
+cucsComputePCIeFatalReceiveStatsBufferOverflowErrors1HourH OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalReceiveStats:bufferOverflowErrors1Hour
+ H managed object property"
+ ::= { cucsComputePCIeFatalReceiveStatsEntry 10 }
+
+cucsComputePCIeFatalReceiveStatsBufferOverflowErrors1Week OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalReceiveStats:bufferOverflowErrors1Week
+ managed object property"
+ ::= { cucsComputePCIeFatalReceiveStatsEntry 11 }
+
+cucsComputePCIeFatalReceiveStatsBufferOverflowErrors1WeekH OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalReceiveStats:bufferOverflowErrors1Week
+ H managed object property"
+ ::= { cucsComputePCIeFatalReceiveStatsEntry 12 }
+
+cucsComputePCIeFatalReceiveStatsErrFatalErrors OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalReceiveStats:errFatalErrors
+ managed object property"
+ ::= { cucsComputePCIeFatalReceiveStatsEntry 13 }
+
+cucsComputePCIeFatalReceiveStatsErrFatalErrors15Min OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalReceiveStats:errFatalErrors15Min
+ managed object property"
+ ::= { cucsComputePCIeFatalReceiveStatsEntry 14 }
+
+cucsComputePCIeFatalReceiveStatsErrFatalErrors15MinH OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalReceiveStats:errFatalErrors15MinH
+ managed object property"
+ ::= { cucsComputePCIeFatalReceiveStatsEntry 15 }
+
+cucsComputePCIeFatalReceiveStatsErrFatalErrors1Day OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalReceiveStats:errFatalErrors1Day
+ managed object property"
+ ::= { cucsComputePCIeFatalReceiveStatsEntry 16 }
+
+cucsComputePCIeFatalReceiveStatsErrFatalErrors1DayH OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalReceiveStats:errFatalErrors1DayH
+ managed object property"
+ ::= { cucsComputePCIeFatalReceiveStatsEntry 17 }
+
+cucsComputePCIeFatalReceiveStatsErrFatalErrors1Hour OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalReceiveStats:errFatalErrors1Hour
+ managed object property"
+ ::= { cucsComputePCIeFatalReceiveStatsEntry 18 }
+
+cucsComputePCIeFatalReceiveStatsErrFatalErrors1HourH OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalReceiveStats:errFatalErrors1HourH
+ managed object property"
+ ::= { cucsComputePCIeFatalReceiveStatsEntry 19 }
+
+cucsComputePCIeFatalReceiveStatsErrFatalErrors1Week OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalReceiveStats:errFatalErrors1Week
+ managed object property"
+ ::= { cucsComputePCIeFatalReceiveStatsEntry 20 }
+
+cucsComputePCIeFatalReceiveStatsErrFatalErrors1WeekH OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalReceiveStats:errFatalErrors1WeekH
+ managed object property"
+ ::= { cucsComputePCIeFatalReceiveStatsEntry 21 }
+
+cucsComputePCIeFatalReceiveStatsErrNonFatalErrors OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalReceiveStats:errNonFatalErrors
+ managed object property"
+ ::= { cucsComputePCIeFatalReceiveStatsEntry 22 }
+
+cucsComputePCIeFatalReceiveStatsErrNonFatalErrors15Min OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalReceiveStats:errNonFatalErrors15Min
+ managed object property"
+ ::= { cucsComputePCIeFatalReceiveStatsEntry 23 }
+
+cucsComputePCIeFatalReceiveStatsErrNonFatalErrors15MinH OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalReceiveStats:errNonFatalErrors15MinH
+ managed object property"
+ ::= { cucsComputePCIeFatalReceiveStatsEntry 24 }
+
+cucsComputePCIeFatalReceiveStatsErrNonFatalErrors1Day OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalReceiveStats:errNonFatalErrors1Day
+ managed object property"
+ ::= { cucsComputePCIeFatalReceiveStatsEntry 25 }
+
+cucsComputePCIeFatalReceiveStatsErrNonFatalErrors1DayH OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalReceiveStats:errNonFatalErrors1DayH
+ managed object property"
+ ::= { cucsComputePCIeFatalReceiveStatsEntry 26 }
+
+cucsComputePCIeFatalReceiveStatsErrNonFatalErrors1Hour OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalReceiveStats:errNonFatalErrors1Hour
+ managed object property"
+ ::= { cucsComputePCIeFatalReceiveStatsEntry 27 }
+
+cucsComputePCIeFatalReceiveStatsErrNonFatalErrors1HourH OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalReceiveStats:errNonFatalErrors1HourH
+ managed object property"
+ ::= { cucsComputePCIeFatalReceiveStatsEntry 28 }
+
+cucsComputePCIeFatalReceiveStatsErrNonFatalErrors1Week OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalReceiveStats:errNonFatalErrors1Week
+ managed object property"
+ ::= { cucsComputePCIeFatalReceiveStatsEntry 29 }
+
+cucsComputePCIeFatalReceiveStatsErrNonFatalErrors1WeekH OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalReceiveStats:errNonFatalErrors1WeekH
+ managed object property"
+ ::= { cucsComputePCIeFatalReceiveStatsEntry 30 }
+
+cucsComputePCIeFatalReceiveStatsIntervals OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalReceiveStats:intervals
+ managed object property"
+ ::= { cucsComputePCIeFatalReceiveStatsEntry 31 }
+
+cucsComputePCIeFatalReceiveStatsSuspect OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalReceiveStats:suspect
+ managed object property"
+ ::= { cucsComputePCIeFatalReceiveStatsEntry 32 }
+
+cucsComputePCIeFatalReceiveStatsThresholded OBJECT-TYPE
+ SYNTAX CucsComputePCIeFatalReceiveStatsThresholded
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalReceiveStats:thresholded
+ managed object property"
+ ::= { cucsComputePCIeFatalReceiveStatsEntry 33 }
+
+cucsComputePCIeFatalReceiveStatsTimeCollected OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalReceiveStats:timeCollected
+ managed object property"
+ ::= { cucsComputePCIeFatalReceiveStatsEntry 34 }
+
+cucsComputePCIeFatalReceiveStatsUnsupportedRequestErrors OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalReceiveStats:unsupportedRequestErrors
+ managed object property"
+ ::= { cucsComputePCIeFatalReceiveStatsEntry 35 }
+
+cucsComputePCIeFatalReceiveStatsUnsupportedRequestErrors15Min OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalReceiveStats:unsupportedRequestErrors1
+ 5Min managed object property"
+ ::= { cucsComputePCIeFatalReceiveStatsEntry 36 }
+
+cucsComputePCIeFatalReceiveStatsUnsupportedRequestErrors15MinH OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalReceiveStats:unsupportedRequestErrors1
+ 5MinH managed object property"
+ ::= { cucsComputePCIeFatalReceiveStatsEntry 37 }
+
+cucsComputePCIeFatalReceiveStatsUnsupportedRequestErrors1Day OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalReceiveStats:unsupportedRequestErrors1
+ Day managed object property"
+ ::= { cucsComputePCIeFatalReceiveStatsEntry 38 }
+
+cucsComputePCIeFatalReceiveStatsUnsupportedRequestErrors1DayH OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalReceiveStats:unsupportedRequestErrors1
+ DayH managed object property"
+ ::= { cucsComputePCIeFatalReceiveStatsEntry 39 }
+
+cucsComputePCIeFatalReceiveStatsUnsupportedRequestErrors1Hour OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalReceiveStats:unsupportedRequestErrors1
+ Hour managed object property"
+ ::= { cucsComputePCIeFatalReceiveStatsEntry 40 }
+
+cucsComputePCIeFatalReceiveStatsUnsupportedRequestErrors1HourH OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalReceiveStats:unsupportedRequestErrors1
+ HourH managed object property"
+ ::= { cucsComputePCIeFatalReceiveStatsEntry 41 }
+
+cucsComputePCIeFatalReceiveStatsUnsupportedRequestErrors1Week OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalReceiveStats:unsupportedRequestErrors1
+ Week managed object property"
+ ::= { cucsComputePCIeFatalReceiveStatsEntry 42 }
+
+cucsComputePCIeFatalReceiveStatsUnsupportedRequestErrors1WeekH OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalReceiveStats:unsupportedRequestErrors1
+ WeekH managed object property"
+ ::= { cucsComputePCIeFatalReceiveStatsEntry 43 }
+
+cucsComputePCIeFatalReceiveStatsUpdate OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalReceiveStats:update
+ managed object property"
+ ::= { cucsComputePCIeFatalReceiveStatsEntry 44 }
+
+cucsComputePCIeFatalReceiveStatsBufferOverflowErrors2Weeks OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalReceiveStats:bufferOverflowErrors2Week
+ s managed object property"
+ ::= { cucsComputePCIeFatalReceiveStatsEntry 45 }
+
+cucsComputePCIeFatalReceiveStatsBufferOverflowErrors2WeeksH OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalReceiveStats:bufferOverflowErrors2Week
+ sH managed object property"
+ ::= { cucsComputePCIeFatalReceiveStatsEntry 46 }
+
+cucsComputePCIeFatalReceiveStatsErrFatalErrors2Weeks OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalReceiveStats:errFatalErrors2Weeks
+ managed object property"
+ ::= { cucsComputePCIeFatalReceiveStatsEntry 47 }
+
+cucsComputePCIeFatalReceiveStatsErrFatalErrors2WeeksH OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalReceiveStats:errFatalErrors2WeeksH
+ managed object property"
+ ::= { cucsComputePCIeFatalReceiveStatsEntry 48 }
+
+cucsComputePCIeFatalReceiveStatsErrNonFatalErrors2Weeks OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalReceiveStats:errNonFatalErrors2Weeks
+ managed object property"
+ ::= { cucsComputePCIeFatalReceiveStatsEntry 49 }
+
+cucsComputePCIeFatalReceiveStatsErrNonFatalErrors2WeeksH OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalReceiveStats:errNonFatalErrors2WeeksH
+ managed object property"
+ ::= { cucsComputePCIeFatalReceiveStatsEntry 50 }
+
+cucsComputePCIeFatalReceiveStatsUnsupportedRequestErrors2Weeks OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalReceiveStats:unsupportedRequestErrors2
+ Weeks managed object property"
+ ::= { cucsComputePCIeFatalReceiveStatsEntry 51 }
+
+cucsComputePCIeFatalReceiveStatsUnsupportedRequestErrors2WeeksH OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalReceiveStats:unsupportedRequestErrors2
+ WeeksH managed object property"
+ ::= { cucsComputePCIeFatalReceiveStatsEntry 52 }
+
+cucsComputePCIeFatalStatsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputePCIeFatalStatsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalStats managed object table"
+ ::= { cucsComputeObjects 22 }
+
+cucsComputePCIeFatalStatsEntry OBJECT-TYPE
+ SYNTAX CucsComputePCIeFatalStatsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputePCIeFatalStatsTable table."
+ INDEX { cucsComputePCIeFatalStatsInstanceId }
+ ::= { cucsComputePCIeFatalStatsTable 1 }
+
+CucsComputePCIeFatalStatsEntry ::= SEQUENCE {
+ cucsComputePCIeFatalStatsInstanceId CucsManagedObjectId,
+ cucsComputePCIeFatalStatsDn CucsManagedObjectDn,
+ cucsComputePCIeFatalStatsRn SnmpAdminString,
+ cucsComputePCIeFatalStatsAcsViolationErrors Counter32,
+ cucsComputePCIeFatalStatsAcsViolationErrors15Min Gauge32,
+ cucsComputePCIeFatalStatsAcsViolationErrors15MinH Gauge32,
+ cucsComputePCIeFatalStatsAcsViolationErrors1Day Gauge32,
+ cucsComputePCIeFatalStatsAcsViolationErrors1DayH Gauge32,
+ cucsComputePCIeFatalStatsAcsViolationErrors1Hour Gauge32,
+ cucsComputePCIeFatalStatsAcsViolationErrors1HourH Gauge32,
+ cucsComputePCIeFatalStatsAcsViolationErrors1Week Gauge32,
+ cucsComputePCIeFatalStatsAcsViolationErrors1WeekH Gauge32,
+ cucsComputePCIeFatalStatsIntervals Gauge32,
+ cucsComputePCIeFatalStatsMalformedTLPErrors Counter32,
+ cucsComputePCIeFatalStatsMalformedTLPErrors15Min Gauge32,
+ cucsComputePCIeFatalStatsMalformedTLPErrors15MinH Gauge32,
+ cucsComputePCIeFatalStatsMalformedTLPErrors1Day Gauge32,
+ cucsComputePCIeFatalStatsMalformedTLPErrors1DayH Gauge32,
+ cucsComputePCIeFatalStatsMalformedTLPErrors1Hour Gauge32,
+ cucsComputePCIeFatalStatsMalformedTLPErrors1HourH Gauge32,
+ cucsComputePCIeFatalStatsMalformedTLPErrors1Week Gauge32,
+ cucsComputePCIeFatalStatsMalformedTLPErrors1WeekH Gauge32,
+ cucsComputePCIeFatalStatsPoisonedTLPErrors Counter32,
+ cucsComputePCIeFatalStatsPoisonedTLPErrors15Min Gauge32,
+ cucsComputePCIeFatalStatsPoisonedTLPErrors15MinH Gauge32,
+ cucsComputePCIeFatalStatsPoisonedTLPErrors1Day Gauge32,
+ cucsComputePCIeFatalStatsPoisonedTLPErrors1DayH Gauge32,
+ cucsComputePCIeFatalStatsPoisonedTLPErrors1Hour Gauge32,
+ cucsComputePCIeFatalStatsPoisonedTLPErrors1HourH Gauge32,
+ cucsComputePCIeFatalStatsPoisonedTLPErrors1Week Gauge32,
+ cucsComputePCIeFatalStatsPoisonedTLPErrors1WeekH Gauge32,
+ cucsComputePCIeFatalStatsSurpriseLinkDownErrors Counter32,
+ cucsComputePCIeFatalStatsSurpriseLinkDownErrors15Min Gauge32,
+ cucsComputePCIeFatalStatsSurpriseLinkDownErrors15MinH Gauge32,
+ cucsComputePCIeFatalStatsSurpriseLinkDownErrors1Day Gauge32,
+ cucsComputePCIeFatalStatsSurpriseLinkDownErrors1DayH Gauge32,
+ cucsComputePCIeFatalStatsSurpriseLinkDownErrors1Hour Gauge32,
+ cucsComputePCIeFatalStatsSurpriseLinkDownErrors1HourH Gauge32,
+ cucsComputePCIeFatalStatsSurpriseLinkDownErrors1Week Gauge32,
+ cucsComputePCIeFatalStatsSurpriseLinkDownErrors1WeekH Gauge32,
+ cucsComputePCIeFatalStatsSuspect TruthValue,
+ cucsComputePCIeFatalStatsThresholded CucsComputePCIeFatalStatsThresholded,
+ cucsComputePCIeFatalStatsTimeCollected DateAndTime,
+ cucsComputePCIeFatalStatsUpdate Gauge32,
+ cucsComputePCIeFatalStatsAcsViolationErrors2Weeks Gauge32,
+ cucsComputePCIeFatalStatsAcsViolationErrors2WeeksH Gauge32,
+ cucsComputePCIeFatalStatsMalformedTLPErrors2Weeks Gauge32,
+ cucsComputePCIeFatalStatsMalformedTLPErrors2WeeksH Gauge32,
+ cucsComputePCIeFatalStatsPoisonedTLPErrors2Weeks Gauge32,
+ cucsComputePCIeFatalStatsPoisonedTLPErrors2WeeksH Gauge32,
+ cucsComputePCIeFatalStatsSurpriseLinkDownErrors2Weeks Gauge32,
+ cucsComputePCIeFatalStatsSurpriseLinkDownErrors2WeeksH Gauge32
+}
+
+cucsComputePCIeFatalStatsInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputePCIeFatalStatsEntry 1 }
+
+cucsComputePCIeFatalStatsDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalStats:dn managed object property"
+ ::= { cucsComputePCIeFatalStatsEntry 2 }
+
+cucsComputePCIeFatalStatsRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalStats:rn managed object property"
+ ::= { cucsComputePCIeFatalStatsEntry 3 }
+
+cucsComputePCIeFatalStatsAcsViolationErrors OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalStats:acsViolationErrors
+ managed object property"
+ ::= { cucsComputePCIeFatalStatsEntry 4 }
+
+cucsComputePCIeFatalStatsAcsViolationErrors15Min OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalStats:acsViolationErrors15Min
+ managed object property"
+ ::= { cucsComputePCIeFatalStatsEntry 5 }
+
+cucsComputePCIeFatalStatsAcsViolationErrors15MinH OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalStats:acsViolationErrors15MinH
+ managed object property"
+ ::= { cucsComputePCIeFatalStatsEntry 6 }
+
+cucsComputePCIeFatalStatsAcsViolationErrors1Day OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalStats:acsViolationErrors1Day
+ managed object property"
+ ::= { cucsComputePCIeFatalStatsEntry 7 }
+
+cucsComputePCIeFatalStatsAcsViolationErrors1DayH OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalStats:acsViolationErrors1DayH
+ managed object property"
+ ::= { cucsComputePCIeFatalStatsEntry 8 }
+
+cucsComputePCIeFatalStatsAcsViolationErrors1Hour OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalStats:acsViolationErrors1Hour
+ managed object property"
+ ::= { cucsComputePCIeFatalStatsEntry 9 }
+
+cucsComputePCIeFatalStatsAcsViolationErrors1HourH OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalStats:acsViolationErrors1HourH
+ managed object property"
+ ::= { cucsComputePCIeFatalStatsEntry 10 }
+
+cucsComputePCIeFatalStatsAcsViolationErrors1Week OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalStats:acsViolationErrors1Week
+ managed object property"
+ ::= { cucsComputePCIeFatalStatsEntry 11 }
+
+cucsComputePCIeFatalStatsAcsViolationErrors1WeekH OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalStats:acsViolationErrors1WeekH
+ managed object property"
+ ::= { cucsComputePCIeFatalStatsEntry 12 }
+
+cucsComputePCIeFatalStatsIntervals OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalStats:intervals managed
+ object property"
+ ::= { cucsComputePCIeFatalStatsEntry 13 }
+
+cucsComputePCIeFatalStatsMalformedTLPErrors OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalStats:malformedTLPErrors
+ managed object property"
+ ::= { cucsComputePCIeFatalStatsEntry 14 }
+
+cucsComputePCIeFatalStatsMalformedTLPErrors15Min OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalStats:malformedTLPErrors15Min
+ managed object property"
+ ::= { cucsComputePCIeFatalStatsEntry 15 }
+
+cucsComputePCIeFatalStatsMalformedTLPErrors15MinH OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalStats:malformedTLPErrors15MinH
+ managed object property"
+ ::= { cucsComputePCIeFatalStatsEntry 16 }
+
+cucsComputePCIeFatalStatsMalformedTLPErrors1Day OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalStats:malformedTLPErrors1Day
+ managed object property"
+ ::= { cucsComputePCIeFatalStatsEntry 17 }
+
+cucsComputePCIeFatalStatsMalformedTLPErrors1DayH OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalStats:malformedTLPErrors1DayH
+ managed object property"
+ ::= { cucsComputePCIeFatalStatsEntry 18 }
+
+cucsComputePCIeFatalStatsMalformedTLPErrors1Hour OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalStats:malformedTLPErrors1Hour
+ managed object property"
+ ::= { cucsComputePCIeFatalStatsEntry 19 }
+
+cucsComputePCIeFatalStatsMalformedTLPErrors1HourH OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalStats:malformedTLPErrors1HourH
+ managed object property"
+ ::= { cucsComputePCIeFatalStatsEntry 20 }
+
+cucsComputePCIeFatalStatsMalformedTLPErrors1Week OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalStats:malformedTLPErrors1Week
+ managed object property"
+ ::= { cucsComputePCIeFatalStatsEntry 21 }
+
+cucsComputePCIeFatalStatsMalformedTLPErrors1WeekH OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalStats:malformedTLPErrors1WeekH
+ managed object property"
+ ::= { cucsComputePCIeFatalStatsEntry 22 }
+
+cucsComputePCIeFatalStatsPoisonedTLPErrors OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalStats:poisonedTLPErrors
+ managed object property"
+ ::= { cucsComputePCIeFatalStatsEntry 23 }
+
+cucsComputePCIeFatalStatsPoisonedTLPErrors15Min OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalStats:poisonedTLPErrors15Min
+ managed object property"
+ ::= { cucsComputePCIeFatalStatsEntry 24 }
+
+cucsComputePCIeFatalStatsPoisonedTLPErrors15MinH OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalStats:poisonedTLPErrors15MinH
+ managed object property"
+ ::= { cucsComputePCIeFatalStatsEntry 25 }
+
+cucsComputePCIeFatalStatsPoisonedTLPErrors1Day OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalStats:poisonedTLPErrors1Day
+ managed object property"
+ ::= { cucsComputePCIeFatalStatsEntry 26 }
+
+cucsComputePCIeFatalStatsPoisonedTLPErrors1DayH OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalStats:poisonedTLPErrors1DayH
+ managed object property"
+ ::= { cucsComputePCIeFatalStatsEntry 27 }
+
+cucsComputePCIeFatalStatsPoisonedTLPErrors1Hour OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalStats:poisonedTLPErrors1Hour
+ managed object property"
+ ::= { cucsComputePCIeFatalStatsEntry 28 }
+
+cucsComputePCIeFatalStatsPoisonedTLPErrors1HourH OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalStats:poisonedTLPErrors1HourH
+ managed object property"
+ ::= { cucsComputePCIeFatalStatsEntry 29 }
+
+cucsComputePCIeFatalStatsPoisonedTLPErrors1Week OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalStats:poisonedTLPErrors1Week
+ managed object property"
+ ::= { cucsComputePCIeFatalStatsEntry 30 }
+
+cucsComputePCIeFatalStatsPoisonedTLPErrors1WeekH OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalStats:poisonedTLPErrors1WeekH
+ managed object property"
+ ::= { cucsComputePCIeFatalStatsEntry 31 }
+
+cucsComputePCIeFatalStatsSurpriseLinkDownErrors OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalStats:surpriseLinkDownErrors
+ managed object property"
+ ::= { cucsComputePCIeFatalStatsEntry 32 }
+
+cucsComputePCIeFatalStatsSurpriseLinkDownErrors15Min OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalStats:surpriseLinkDownErrors15Min
+ managed object property"
+ ::= { cucsComputePCIeFatalStatsEntry 33 }
+
+cucsComputePCIeFatalStatsSurpriseLinkDownErrors15MinH OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalStats:surpriseLinkDownErrors15MinH
+ managed object property"
+ ::= { cucsComputePCIeFatalStatsEntry 34 }
+
+cucsComputePCIeFatalStatsSurpriseLinkDownErrors1Day OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalStats:surpriseLinkDownErrors1Day
+ managed object property"
+ ::= { cucsComputePCIeFatalStatsEntry 35 }
+
+cucsComputePCIeFatalStatsSurpriseLinkDownErrors1DayH OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalStats:surpriseLinkDownErrors1DayH
+ managed object property"
+ ::= { cucsComputePCIeFatalStatsEntry 36 }
+
+cucsComputePCIeFatalStatsSurpriseLinkDownErrors1Hour OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalStats:surpriseLinkDownErrors1Hour
+ managed object property"
+ ::= { cucsComputePCIeFatalStatsEntry 37 }
+
+cucsComputePCIeFatalStatsSurpriseLinkDownErrors1HourH OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalStats:surpriseLinkDownErrors1HourH
+ managed object property"
+ ::= { cucsComputePCIeFatalStatsEntry 38 }
+
+cucsComputePCIeFatalStatsSurpriseLinkDownErrors1Week OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalStats:surpriseLinkDownErrors1Week
+ managed object property"
+ ::= { cucsComputePCIeFatalStatsEntry 39 }
+
+cucsComputePCIeFatalStatsSurpriseLinkDownErrors1WeekH OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalStats:surpriseLinkDownErrors1WeekH
+ managed object property"
+ ::= { cucsComputePCIeFatalStatsEntry 40 }
+
+cucsComputePCIeFatalStatsSuspect OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalStats:suspect managed object property"
+ ::= { cucsComputePCIeFatalStatsEntry 41 }
+
+cucsComputePCIeFatalStatsThresholded OBJECT-TYPE
+ SYNTAX CucsComputePCIeFatalStatsThresholded
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalStats:thresholded managed
+ object property"
+ ::= { cucsComputePCIeFatalStatsEntry 42 }
+
+cucsComputePCIeFatalStatsTimeCollected OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalStats:timeCollected
+ managed object property"
+ ::= { cucsComputePCIeFatalStatsEntry 43 }
+
+cucsComputePCIeFatalStatsUpdate OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalStats:update managed object property"
+ ::= { cucsComputePCIeFatalStatsEntry 44 }
+
+cucsComputePCIeFatalStatsAcsViolationErrors2Weeks OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalStats:acsViolationErrors2Weeks
+ managed object property"
+ ::= { cucsComputePCIeFatalStatsEntry 45 }
+
+cucsComputePCIeFatalStatsAcsViolationErrors2WeeksH OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalStats:acsViolationErrors2WeeksH
+ managed object property"
+ ::= { cucsComputePCIeFatalStatsEntry 46 }
+
+cucsComputePCIeFatalStatsMalformedTLPErrors2Weeks OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalStats:malformedTLPErrors2Weeks
+ managed object property"
+ ::= { cucsComputePCIeFatalStatsEntry 47 }
+
+cucsComputePCIeFatalStatsMalformedTLPErrors2WeeksH OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalStats:malformedTLPErrors2WeeksH
+ managed object property"
+ ::= { cucsComputePCIeFatalStatsEntry 48 }
+
+cucsComputePCIeFatalStatsPoisonedTLPErrors2Weeks OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalStats:poisonedTLPErrors2Weeks
+ managed object property"
+ ::= { cucsComputePCIeFatalStatsEntry 49 }
+
+cucsComputePCIeFatalStatsPoisonedTLPErrors2WeeksH OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalStats:poisonedTLPErrors2WeeksH
+ managed object property"
+ ::= { cucsComputePCIeFatalStatsEntry 50 }
+
+cucsComputePCIeFatalStatsSurpriseLinkDownErrors2Weeks OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalStats:surpriseLinkDownErrors2Weeks
+ managed object property"
+ ::= { cucsComputePCIeFatalStatsEntry 51 }
+
+cucsComputePCIeFatalStatsSurpriseLinkDownErrors2WeeksH OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PCIeFatalStats:surpriseLinkDownErrors2WeeksH
+ managed object property"
+ ::= { cucsComputePCIeFatalStatsEntry 52 }
+
+cucsComputePciCapTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputePciCapEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PciCap managed object table"
+ ::= { cucsComputeObjects 23 }
+
+cucsComputePciCapEntry OBJECT-TYPE
+ SYNTAX CucsComputePciCapEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputePciCapTable table."
+ INDEX { cucsComputePciCapInstanceId }
+ ::= { cucsComputePciCapTable 1 }
+
+CucsComputePciCapEntry ::= SEQUENCE {
+ cucsComputePciCapInstanceId CucsManagedObjectId,
+ cucsComputePciCapDn CucsManagedObjectDn,
+ cucsComputePciCapRn SnmpAdminString,
+ cucsComputePciCapNumOfPhysSlots Gauge32,
+ cucsComputePciCapOrder CucsComputePciCapOrder,
+ cucsComputePciCapStartsWith Gauge32,
+ cucsComputePciCapMaxBusIdPerSlot Gauge32
+}
+
+cucsComputePciCapInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputePciCapEntry 1 }
+
+cucsComputePciCapDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PciCap:dn managed object property"
+ ::= { cucsComputePciCapEntry 2 }
+
+cucsComputePciCapRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PciCap:rn managed object property"
+ ::= { cucsComputePciCapEntry 3 }
+
+cucsComputePciCapNumOfPhysSlots OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PciCap:numOfPhysSlots managed object property"
+ ::= { cucsComputePciCapEntry 4 }
+
+cucsComputePciCapOrder OBJECT-TYPE
+ SYNTAX CucsComputePciCapOrder
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PciCap:order managed object property"
+ ::= { cucsComputePciCapEntry 5 }
+
+cucsComputePciCapStartsWith OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PciCap:startsWith managed object property"
+ ::= { cucsComputePciCapEntry 6 }
+
+cucsComputePciCapMaxBusIdPerSlot OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PciCap:maxBusIdPerSlot managed object property"
+ ::= { cucsComputePciCapEntry 7 }
+
+cucsComputePciSlotScanDefTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputePciSlotScanDefEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PciSlotScanDef managed object table"
+ ::= { cucsComputeObjects 58 }
+
+cucsComputePciSlotScanDefEntry OBJECT-TYPE
+ SYNTAX CucsComputePciSlotScanDefEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputePciSlotScanDefTable table."
+ INDEX { cucsComputePciSlotScanDefInstanceId }
+ ::= { cucsComputePciSlotScanDefTable 1 }
+
+CucsComputePciSlotScanDefEntry ::= SEQUENCE {
+ cucsComputePciSlotScanDefInstanceId CucsManagedObjectId,
+ cucsComputePciSlotScanDefDn CucsManagedObjectDn,
+ cucsComputePciSlotScanDefRn SnmpAdminString,
+ cucsComputePciSlotScanDefDescr SnmpAdminString,
+ cucsComputePciSlotScanDefIntId SnmpAdminString,
+ cucsComputePciSlotScanDefName SnmpAdminString,
+ cucsComputePciSlotScanDefPolicyLevel Gauge32,
+ cucsComputePciSlotScanDefPolicyOwner CucsPolicyPolicyOwner,
+ cucsComputePciSlotScanDefScanOrder Gauge32,
+ cucsComputePciSlotScanDefSlotId Gauge32
+}
+
+cucsComputePciSlotScanDefInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputePciSlotScanDefEntry 1 }
+
+cucsComputePciSlotScanDefDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PciSlotScanDef:dn managed object property"
+ ::= { cucsComputePciSlotScanDefEntry 2 }
+
+cucsComputePciSlotScanDefRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PciSlotScanDef:rn managed object property"
+ ::= { cucsComputePciSlotScanDefEntry 3 }
+
+cucsComputePciSlotScanDefDescr OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PciSlotScanDef:descr managed object property"
+ ::= { cucsComputePciSlotScanDefEntry 4 }
+
+cucsComputePciSlotScanDefIntId OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PciSlotScanDef:intId managed object property"
+ ::= { cucsComputePciSlotScanDefEntry 5 }
+
+cucsComputePciSlotScanDefName OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PciSlotScanDef:name managed object property"
+ ::= { cucsComputePciSlotScanDefEntry 6 }
+
+cucsComputePciSlotScanDefPolicyLevel OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PciSlotScanDef:policyLevel managed
+ object property"
+ ::= { cucsComputePciSlotScanDefEntry 7 }
+
+cucsComputePciSlotScanDefPolicyOwner OBJECT-TYPE
+ SYNTAX CucsPolicyPolicyOwner
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PciSlotScanDef:policyOwner managed
+ object property"
+ ::= { cucsComputePciSlotScanDefEntry 8 }
+
+cucsComputePciSlotScanDefScanOrder OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PciSlotScanDef:scanOrder managed
+ object property"
+ ::= { cucsComputePciSlotScanDefEntry 9 }
+
+cucsComputePciSlotScanDefSlotId OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PciSlotScanDef:slotId managed object property"
+ ::= { cucsComputePciSlotScanDefEntry 10 }
+
+cucsComputePhysicalAssocCtxTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputePhysicalAssocCtxEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PhysicalAssocCtx managed object table"
+ ::= { cucsComputeObjects 41 }
+
+cucsComputePhysicalAssocCtxEntry OBJECT-TYPE
+ SYNTAX CucsComputePhysicalAssocCtxEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputePhysicalAssocCtxTable table."
+ INDEX { cucsComputePhysicalAssocCtxInstanceId }
+ ::= { cucsComputePhysicalAssocCtxTable 1 }
+
+CucsComputePhysicalAssocCtxEntry ::= SEQUENCE {
+ cucsComputePhysicalAssocCtxInstanceId CucsManagedObjectId,
+ cucsComputePhysicalAssocCtxDn CucsManagedObjectDn,
+ cucsComputePhysicalAssocCtxRn SnmpAdminString,
+ cucsComputePhysicalAssocCtxFruCapDn SnmpAdminString
+}
+
+cucsComputePhysicalAssocCtxInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputePhysicalAssocCtxEntry 1 }
+
+cucsComputePhysicalAssocCtxDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PhysicalAssocCtx:dn managed object property"
+ ::= { cucsComputePhysicalAssocCtxEntry 2 }
+
+cucsComputePhysicalAssocCtxRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PhysicalAssocCtx:rn managed object property"
+ ::= { cucsComputePhysicalAssocCtxEntry 3 }
+
+cucsComputePhysicalAssocCtxFruCapDn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PhysicalAssocCtx:fruCapDn managed
+ object property"
+ ::= { cucsComputePhysicalAssocCtxEntry 4 }
+
+cucsComputePhysicalFsmTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputePhysicalFsmEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PhysicalFsm managed object table"
+ ::= { cucsComputeObjects 50 }
+
+cucsComputePhysicalFsmEntry OBJECT-TYPE
+ SYNTAX CucsComputePhysicalFsmEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputePhysicalFsmTable table."
+ INDEX { cucsComputePhysicalFsmInstanceId }
+ ::= { cucsComputePhysicalFsmTable 1 }
+
+CucsComputePhysicalFsmEntry ::= SEQUENCE {
+ cucsComputePhysicalFsmInstanceId CucsManagedObjectId,
+ cucsComputePhysicalFsmDn CucsManagedObjectDn,
+ cucsComputePhysicalFsmRn SnmpAdminString,
+ cucsComputePhysicalFsmCompletionTime DateAndTime,
+ cucsComputePhysicalFsmCurrentFsm CucsComputePhysicalFsmCurrentFsm,
+ cucsComputePhysicalFsmDescr SnmpAdminString,
+ cucsComputePhysicalFsmFsmStatus CucsFsmFsmStageStatus,
+ cucsComputePhysicalFsmProgress Gauge32,
+ cucsComputePhysicalFsmRmtErrCode Gauge32,
+ cucsComputePhysicalFsmRmtErrDescr SnmpAdminString,
+ cucsComputePhysicalFsmRmtRslt CucsConditionRemoteInvRslt
+}
+
+cucsComputePhysicalFsmInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputePhysicalFsmEntry 1 }
+
+cucsComputePhysicalFsmDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PhysicalFsm:dn managed object property"
+ ::= { cucsComputePhysicalFsmEntry 2 }
+
+cucsComputePhysicalFsmRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PhysicalFsm:rn managed object property"
+ ::= { cucsComputePhysicalFsmEntry 3 }
+
+cucsComputePhysicalFsmCompletionTime OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PhysicalFsm:completionTime managed
+ object property"
+ ::= { cucsComputePhysicalFsmEntry 4 }
+
+cucsComputePhysicalFsmCurrentFsm OBJECT-TYPE
+ SYNTAX CucsComputePhysicalFsmCurrentFsm
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PhysicalFsm:currentFsm managed object property"
+ ::= { cucsComputePhysicalFsmEntry 5 }
+
+cucsComputePhysicalFsmDescr OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PhysicalFsm:descr managed object property"
+ ::= { cucsComputePhysicalFsmEntry 6 }
+
+cucsComputePhysicalFsmFsmStatus OBJECT-TYPE
+ SYNTAX CucsFsmFsmStageStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PhysicalFsm:fsmStatus managed object property"
+ ::= { cucsComputePhysicalFsmEntry 7 }
+
+cucsComputePhysicalFsmProgress OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PhysicalFsm:progress managed object property"
+ ::= { cucsComputePhysicalFsmEntry 8 }
+
+cucsComputePhysicalFsmRmtErrCode OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PhysicalFsm:rmtErrCode managed object property"
+ ::= { cucsComputePhysicalFsmEntry 9 }
+
+cucsComputePhysicalFsmRmtErrDescr OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PhysicalFsm:rmtErrDescr managed
+ object property"
+ ::= { cucsComputePhysicalFsmEntry 10 }
+
+cucsComputePhysicalFsmRmtRslt OBJECT-TYPE
+ SYNTAX CucsConditionRemoteInvRslt
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PhysicalFsm:rmtRslt managed object property"
+ ::= { cucsComputePhysicalFsmEntry 11 }
+
+cucsComputePhysicalFsmStageTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputePhysicalFsmStageEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PhysicalFsmStage managed object table"
+ ::= { cucsComputeObjects 51 }
+
+cucsComputePhysicalFsmStageEntry OBJECT-TYPE
+ SYNTAX CucsComputePhysicalFsmStageEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputePhysicalFsmStageTable table."
+ INDEX { cucsComputePhysicalFsmStageInstanceId }
+ ::= { cucsComputePhysicalFsmStageTable 1 }
+
+CucsComputePhysicalFsmStageEntry ::= SEQUENCE {
+ cucsComputePhysicalFsmStageInstanceId CucsManagedObjectId,
+ cucsComputePhysicalFsmStageDn CucsManagedObjectDn,
+ cucsComputePhysicalFsmStageRn SnmpAdminString,
+ cucsComputePhysicalFsmStageDescr SnmpAdminString,
+ cucsComputePhysicalFsmStageLastUpdateTime DateAndTime,
+ cucsComputePhysicalFsmStageName CucsComputePhysicalFsmStageName,
+ cucsComputePhysicalFsmStageOrder Gauge32,
+ cucsComputePhysicalFsmStageRetry Gauge32,
+ cucsComputePhysicalFsmStageStageStatus CucsFsmFsmStageStatus
+}
+
+cucsComputePhysicalFsmStageInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputePhysicalFsmStageEntry 1 }
+
+cucsComputePhysicalFsmStageDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PhysicalFsmStage:dn managed object property"
+ ::= { cucsComputePhysicalFsmStageEntry 2 }
+
+cucsComputePhysicalFsmStageRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PhysicalFsmStage:rn managed object property"
+ ::= { cucsComputePhysicalFsmStageEntry 3 }
+
+cucsComputePhysicalFsmStageDescr OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PhysicalFsmStage:descr managed object property"
+ ::= { cucsComputePhysicalFsmStageEntry 4 }
+
+cucsComputePhysicalFsmStageLastUpdateTime OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PhysicalFsmStage:lastUpdateTime
+ managed object property"
+ ::= { cucsComputePhysicalFsmStageEntry 5 }
+
+cucsComputePhysicalFsmStageName OBJECT-TYPE
+ SYNTAX CucsComputePhysicalFsmStageName
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PhysicalFsmStage:name managed object property"
+ ::= { cucsComputePhysicalFsmStageEntry 6 }
+
+cucsComputePhysicalFsmStageOrder OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PhysicalFsmStage:order managed object property"
+ ::= { cucsComputePhysicalFsmStageEntry 7 }
+
+cucsComputePhysicalFsmStageRetry OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PhysicalFsmStage:retry managed object property"
+ ::= { cucsComputePhysicalFsmStageEntry 8 }
+
+cucsComputePhysicalFsmStageStageStatus OBJECT-TYPE
+ SYNTAX CucsFsmFsmStageStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PhysicalFsmStage:stageStatus
+ managed object property"
+ ::= { cucsComputePhysicalFsmStageEntry 9 }
+
+cucsComputePhysicalFsmTaskTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputePhysicalFsmTaskEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PhysicalFsmTask managed object table"
+ ::= { cucsComputeObjects 24 }
+
+cucsComputePhysicalFsmTaskEntry OBJECT-TYPE
+ SYNTAX CucsComputePhysicalFsmTaskEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputePhysicalFsmTaskTable table."
+ INDEX { cucsComputePhysicalFsmTaskInstanceId }
+ ::= { cucsComputePhysicalFsmTaskTable 1 }
+
+CucsComputePhysicalFsmTaskEntry ::= SEQUENCE {
+ cucsComputePhysicalFsmTaskInstanceId CucsManagedObjectId,
+ cucsComputePhysicalFsmTaskDn CucsManagedObjectDn,
+ cucsComputePhysicalFsmTaskRn SnmpAdminString,
+ cucsComputePhysicalFsmTaskCompletion CucsFsmCompletion,
+ cucsComputePhysicalFsmTaskFlags CucsComputePhysicalFsmTaskFlags,
+ cucsComputePhysicalFsmTaskItem CucsComputePhysicalFsmTaskItem,
+ cucsComputePhysicalFsmTaskSeqId Gauge32
+}
+
+cucsComputePhysicalFsmTaskInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputePhysicalFsmTaskEntry 1 }
+
+cucsComputePhysicalFsmTaskDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PhysicalFsmTask:dn managed object property"
+ ::= { cucsComputePhysicalFsmTaskEntry 2 }
+
+cucsComputePhysicalFsmTaskRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PhysicalFsmTask:rn managed object property"
+ ::= { cucsComputePhysicalFsmTaskEntry 3 }
+
+cucsComputePhysicalFsmTaskCompletion OBJECT-TYPE
+ SYNTAX CucsFsmCompletion
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PhysicalFsmTask:completion managed
+ object property"
+ ::= { cucsComputePhysicalFsmTaskEntry 4 }
+
+cucsComputePhysicalFsmTaskFlags OBJECT-TYPE
+ SYNTAX CucsComputePhysicalFsmTaskFlags
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PhysicalFsmTask:flags managed object property"
+ ::= { cucsComputePhysicalFsmTaskEntry 5 }
+
+cucsComputePhysicalFsmTaskItem OBJECT-TYPE
+ SYNTAX CucsComputePhysicalFsmTaskItem
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PhysicalFsmTask:item managed object property"
+ ::= { cucsComputePhysicalFsmTaskEntry 6 }
+
+cucsComputePhysicalFsmTaskSeqId OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PhysicalFsmTask:seqId managed object property"
+ ::= { cucsComputePhysicalFsmTaskEntry 7 }
+
+cucsComputePhysicalQualTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputePhysicalQualEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PhysicalQual managed object table"
+ ::= { cucsComputeObjects 25 }
+
+cucsComputePhysicalQualEntry OBJECT-TYPE
+ SYNTAX CucsComputePhysicalQualEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputePhysicalQualTable table."
+ INDEX { cucsComputePhysicalQualInstanceId }
+ ::= { cucsComputePhysicalQualTable 1 }
+
+CucsComputePhysicalQualEntry ::= SEQUENCE {
+ cucsComputePhysicalQualInstanceId CucsManagedObjectId,
+ cucsComputePhysicalQualDn CucsManagedObjectDn,
+ cucsComputePhysicalQualRn SnmpAdminString,
+ cucsComputePhysicalQualModel SnmpAdminString,
+ cucsComputePhysicalQualPropAcl Unsigned64
+}
+
+cucsComputePhysicalQualInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputePhysicalQualEntry 1 }
+
+cucsComputePhysicalQualDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PhysicalQual:dn managed object property"
+ ::= { cucsComputePhysicalQualEntry 2 }
+
+cucsComputePhysicalQualRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PhysicalQual:rn managed object property"
+ ::= { cucsComputePhysicalQualEntry 3 }
+
+cucsComputePhysicalQualModel OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PhysicalQual:model managed object property"
+ ::= { cucsComputePhysicalQualEntry 4 }
+
+cucsComputePhysicalQualPropAcl OBJECT-TYPE
+ SYNTAX Unsigned64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PhysicalQual:propAcl managed object property"
+ ::= { cucsComputePhysicalQualEntry 5 }
+
+cucsComputePlatformTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputePlatformEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Platform managed object table"
+ ::= { cucsComputeObjects 26 }
+
+cucsComputePlatformEntry OBJECT-TYPE
+ SYNTAX CucsComputePlatformEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputePlatformTable table."
+ INDEX { cucsComputePlatformInstanceId }
+ ::= { cucsComputePlatformTable 1 }
+
+CucsComputePlatformEntry ::= SEQUENCE {
+ cucsComputePlatformInstanceId CucsManagedObjectId,
+ cucsComputePlatformDn CucsManagedObjectDn,
+ cucsComputePlatformRn SnmpAdminString,
+ cucsComputePlatformModel SnmpAdminString,
+ cucsComputePlatformRevision SnmpAdminString,
+ cucsComputePlatformVendor SnmpAdminString,
+ cucsComputePlatformProductName SnmpAdminString,
+ cucsComputePlatformPropAcl Unsigned64
+}
+
+cucsComputePlatformInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputePlatformEntry 1 }
+
+cucsComputePlatformDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Platform:dn managed object property"
+ ::= { cucsComputePlatformEntry 2 }
+
+cucsComputePlatformRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Platform:rn managed object property"
+ ::= { cucsComputePlatformEntry 3 }
+
+cucsComputePlatformModel OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Platform:model managed object property"
+ ::= { cucsComputePlatformEntry 4 }
+
+cucsComputePlatformRevision OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Platform:revision managed object property"
+ ::= { cucsComputePlatformEntry 5 }
+
+cucsComputePlatformVendor OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Platform:vendor managed object property"
+ ::= { cucsComputePlatformEntry 6 }
+
+cucsComputePlatformProductName OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Platform:productName managed object property"
+ ::= { cucsComputePlatformEntry 7 }
+
+cucsComputePlatformPropAcl OBJECT-TYPE
+ SYNTAX Unsigned64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Platform:propAcl managed object property"
+ ::= { cucsComputePlatformEntry 8 }
+
+cucsComputePnuOSImageTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputePnuOSImageEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PnuOSImage managed object table"
+ ::= { cucsComputeObjects 47 }
+
+cucsComputePnuOSImageEntry OBJECT-TYPE
+ SYNTAX CucsComputePnuOSImageEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputePnuOSImageTable table."
+ INDEX { cucsComputePnuOSImageInstanceId }
+ ::= { cucsComputePnuOSImageTable 1 }
+
+CucsComputePnuOSImageEntry ::= SEQUENCE {
+ cucsComputePnuOSImageInstanceId CucsManagedObjectId,
+ cucsComputePnuOSImageDn CucsManagedObjectDn,
+ cucsComputePnuOSImageRn SnmpAdminString,
+ cucsComputePnuOSImageImgLoc SnmpAdminString,
+ cucsComputePnuOSImageImgName SnmpAdminString
+}
+
+cucsComputePnuOSImageInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputePnuOSImageEntry 1 }
+
+cucsComputePnuOSImageDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PnuOSImage:dn managed object property"
+ ::= { cucsComputePnuOSImageEntry 2 }
+
+cucsComputePnuOSImageRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PnuOSImage:rn managed object property"
+ ::= { cucsComputePnuOSImageEntry 3 }
+
+cucsComputePnuOSImageImgLoc OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PnuOSImage:imgLoc managed object property"
+ ::= { cucsComputePnuOSImageEntry 4 }
+
+cucsComputePnuOSImageImgName OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PnuOSImage:imgName managed object property"
+ ::= { cucsComputePnuOSImageEntry 5 }
+
+cucsComputePoolTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputePoolEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Pool managed object table"
+ ::= { cucsComputeObjects 27 }
+
+cucsComputePoolEntry OBJECT-TYPE
+ SYNTAX CucsComputePoolEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputePoolTable table."
+ INDEX { cucsComputePoolInstanceId }
+ ::= { cucsComputePoolTable 1 }
+
+CucsComputePoolEntry ::= SEQUENCE {
+ cucsComputePoolInstanceId CucsManagedObjectId,
+ cucsComputePoolDn CucsManagedObjectDn,
+ cucsComputePoolRn SnmpAdminString,
+ cucsComputePoolAssigned Gauge32,
+ cucsComputePoolDescr SnmpAdminString,
+ cucsComputePoolIntId SnmpAdminString,
+ cucsComputePoolName SnmpAdminString,
+ cucsComputePoolSize Gauge32,
+ cucsComputePoolAssignmentOrder CucsPoolPoolAssignmentOrder,
+ cucsComputePoolPolicyLevel Gauge32,
+ cucsComputePoolPolicyOwner CucsPolicyPolicyOwner
+}
+
+cucsComputePoolInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputePoolEntry 1 }
+
+cucsComputePoolDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Pool:dn managed object property"
+ ::= { cucsComputePoolEntry 2 }
+
+cucsComputePoolRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Pool:rn managed object property"
+ ::= { cucsComputePoolEntry 3 }
+
+cucsComputePoolAssigned OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Pool:assigned managed object property"
+ ::= { cucsComputePoolEntry 4 }
+
+cucsComputePoolDescr OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Pool:descr managed object property"
+ ::= { cucsComputePoolEntry 5 }
+
+cucsComputePoolIntId OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Pool:intId managed object property"
+ ::= { cucsComputePoolEntry 6 }
+
+cucsComputePoolName OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Pool:name managed object property"
+ ::= { cucsComputePoolEntry 7 }
+
+cucsComputePoolSize OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Pool:size managed object property"
+ ::= { cucsComputePoolEntry 8 }
+
+cucsComputePoolAssignmentOrder OBJECT-TYPE
+ SYNTAX CucsPoolPoolAssignmentOrder
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Pool:assignmentOrder managed object property"
+ ::= { cucsComputePoolEntry 9 }
+
+cucsComputePoolPolicyLevel OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Pool:policyLevel managed object property"
+ ::= { cucsComputePoolEntry 10 }
+
+cucsComputePoolPolicyOwner OBJECT-TYPE
+ SYNTAX CucsPolicyPolicyOwner
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Pool:policyOwner managed object property"
+ ::= { cucsComputePoolEntry 11 }
+
+cucsComputePoolPolicyRefTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputePoolPolicyRefEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PoolPolicyRef managed object table"
+ ::= { cucsComputeObjects 42 }
+
+cucsComputePoolPolicyRefEntry OBJECT-TYPE
+ SYNTAX CucsComputePoolPolicyRefEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputePoolPolicyRefTable table."
+ INDEX { cucsComputePoolPolicyRefInstanceId }
+ ::= { cucsComputePoolPolicyRefTable 1 }
+
+CucsComputePoolPolicyRefEntry ::= SEQUENCE {
+ cucsComputePoolPolicyRefInstanceId CucsManagedObjectId,
+ cucsComputePoolPolicyRefDn CucsManagedObjectDn,
+ cucsComputePoolPolicyRefRn SnmpAdminString,
+ cucsComputePoolPolicyRefId Unsigned64,
+ cucsComputePoolPolicyRefPolicyDn SnmpAdminString
+}
+
+cucsComputePoolPolicyRefInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputePoolPolicyRefEntry 1 }
+
+cucsComputePoolPolicyRefDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PoolPolicyRef:dn managed object property"
+ ::= { cucsComputePoolPolicyRefEntry 2 }
+
+cucsComputePoolPolicyRefRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PoolPolicyRef:rn managed object property"
+ ::= { cucsComputePoolPolicyRefEntry 3 }
+
+cucsComputePoolPolicyRefId OBJECT-TYPE
+ SYNTAX Unsigned64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PoolPolicyRef:id managed object property"
+ ::= { cucsComputePoolPolicyRefEntry 4 }
+
+cucsComputePoolPolicyRefPolicyDn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PoolPolicyRef:policyDn managed object property"
+ ::= { cucsComputePoolPolicyRefEntry 5 }
+
+cucsComputePoolableTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputePoolableEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Poolable managed object table"
+ ::= { cucsComputeObjects 28 }
+
+cucsComputePoolableEntry OBJECT-TYPE
+ SYNTAX CucsComputePoolableEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputePoolableTable table."
+ INDEX { cucsComputePoolableInstanceId }
+ ::= { cucsComputePoolableTable 1 }
+
+CucsComputePoolableEntry ::= SEQUENCE {
+ cucsComputePoolableInstanceId CucsManagedObjectId,
+ cucsComputePoolableDn CucsManagedObjectDn,
+ cucsComputePoolableRn SnmpAdminString,
+ cucsComputePoolableId Unsigned64,
+ cucsComputePoolablePoolDn SnmpAdminString
+}
+
+cucsComputePoolableInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputePoolableEntry 1 }
+
+cucsComputePoolableDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Poolable:dn managed object property"
+ ::= { cucsComputePoolableEntry 2 }
+
+cucsComputePoolableRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Poolable:rn managed object property"
+ ::= { cucsComputePoolableEntry 3 }
+
+cucsComputePoolableId OBJECT-TYPE
+ SYNTAX Unsigned64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Poolable:id managed object property"
+ ::= { cucsComputePoolableEntry 4 }
+
+cucsComputePoolablePoolDn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Poolable:poolDn managed object property"
+ ::= { cucsComputePoolableEntry 5 }
+
+cucsComputePooledEnclosureComputeSlotTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputePooledEnclosureComputeSlotEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PooledEnclosureComputeSlot managed
+ object table"
+ ::= { cucsComputeObjects 73 }
+
+cucsComputePooledEnclosureComputeSlotEntry OBJECT-TYPE
+ SYNTAX CucsComputePooledEnclosureComputeSlotEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputePooledEnclosureComputeSlotTable table."
+ INDEX { cucsComputePooledEnclosureComputeSlotInstanceId }
+ ::= { cucsComputePooledEnclosureComputeSlotTable 1 }
+
+CucsComputePooledEnclosureComputeSlotEntry ::= SEQUENCE {
+ cucsComputePooledEnclosureComputeSlotInstanceId CucsManagedObjectId,
+ cucsComputePooledEnclosureComputeSlotDn CucsManagedObjectDn,
+ cucsComputePooledEnclosureComputeSlotRn SnmpAdminString,
+ cucsComputePooledEnclosureComputeSlotAssigned TruthValue,
+ cucsComputePooledEnclosureComputeSlotAssignedToDn SnmpAdminString,
+ cucsComputePooledEnclosureComputeSlotChassisId Gauge32,
+ cucsComputePooledEnclosureComputeSlotOwner CucsComputeOwner,
+ cucsComputePooledEnclosureComputeSlotPoolableDn SnmpAdminString,
+ cucsComputePooledEnclosureComputeSlotPrevAssignedToDn SnmpAdminString,
+ cucsComputePooledEnclosureComputeSlotServerInstanceId CucsComputePooledEnclosureComputeSlotServerInstanceId,
+ cucsComputePooledEnclosureComputeSlotSlotId CucsComputePooledEnclosureComputeSlotSlotId
+}
+
+cucsComputePooledEnclosureComputeSlotInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputePooledEnclosureComputeSlotEntry 1 }
+
+cucsComputePooledEnclosureComputeSlotDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PooledEnclosureComputeSlot:dn
+ managed object property"
+ ::= { cucsComputePooledEnclosureComputeSlotEntry 2 }
+
+cucsComputePooledEnclosureComputeSlotRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PooledEnclosureComputeSlot:rn
+ managed object property"
+ ::= { cucsComputePooledEnclosureComputeSlotEntry 3 }
+
+cucsComputePooledEnclosureComputeSlotAssigned OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PooledEnclosureComputeSlot:assigned
+ managed object property"
+ ::= { cucsComputePooledEnclosureComputeSlotEntry 4 }
+
+cucsComputePooledEnclosureComputeSlotAssignedToDn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PooledEnclosureComputeSlot:assignedToDn
+ managed object property"
+ ::= { cucsComputePooledEnclosureComputeSlotEntry 5 }
+
+cucsComputePooledEnclosureComputeSlotChassisId OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PooledEnclosureComputeSlot:chassisId
+ managed object property"
+ ::= { cucsComputePooledEnclosureComputeSlotEntry 6 }
+
+cucsComputePooledEnclosureComputeSlotOwner OBJECT-TYPE
+ SYNTAX CucsComputeOwner
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PooledEnclosureComputeSlot:owner
+ managed object property"
+ ::= { cucsComputePooledEnclosureComputeSlotEntry 7 }
+
+cucsComputePooledEnclosureComputeSlotPoolableDn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PooledEnclosureComputeSlot:poolableDn
+ managed object property"
+ ::= { cucsComputePooledEnclosureComputeSlotEntry 8 }
+
+cucsComputePooledEnclosureComputeSlotPrevAssignedToDn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PooledEnclosureComputeSlot:prevAssignedToDn
+ managed object property"
+ ::= { cucsComputePooledEnclosureComputeSlotEntry 9 }
+
+cucsComputePooledEnclosureComputeSlotServerInstanceId OBJECT-TYPE
+ SYNTAX CucsComputePooledEnclosureComputeSlotServerInstanceId
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PooledEnclosureComputeSlot:serverInstanceId
+ managed object property"
+ ::= { cucsComputePooledEnclosureComputeSlotEntry 10 }
+
+cucsComputePooledEnclosureComputeSlotSlotId OBJECT-TYPE
+ SYNTAX CucsComputePooledEnclosureComputeSlotSlotId
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PooledEnclosureComputeSlot:slotId
+ managed object property"
+ ::= { cucsComputePooledEnclosureComputeSlotEntry 11 }
+
+cucsComputePooledRackUnitTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputePooledRackUnitEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PooledRackUnit managed object table"
+ ::= { cucsComputeObjects 29 }
+
+cucsComputePooledRackUnitEntry OBJECT-TYPE
+ SYNTAX CucsComputePooledRackUnitEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputePooledRackUnitTable table."
+ INDEX { cucsComputePooledRackUnitInstanceId }
+ ::= { cucsComputePooledRackUnitTable 1 }
+
+CucsComputePooledRackUnitEntry ::= SEQUENCE {
+ cucsComputePooledRackUnitInstanceId CucsManagedObjectId,
+ cucsComputePooledRackUnitDn CucsManagedObjectDn,
+ cucsComputePooledRackUnitRn SnmpAdminString,
+ cucsComputePooledRackUnitAssigned TruthValue,
+ cucsComputePooledRackUnitAssignedToDn SnmpAdminString,
+ cucsComputePooledRackUnitId CucsComputePooledRackUnitId,
+ cucsComputePooledRackUnitOwner CucsComputeOwner,
+ cucsComputePooledRackUnitPoolableDn SnmpAdminString,
+ cucsComputePooledRackUnitPrevAssignedToDn SnmpAdminString
+}
+
+cucsComputePooledRackUnitInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputePooledRackUnitEntry 1 }
+
+cucsComputePooledRackUnitDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PooledRackUnit:dn managed object property"
+ ::= { cucsComputePooledRackUnitEntry 2 }
+
+cucsComputePooledRackUnitRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PooledRackUnit:rn managed object property"
+ ::= { cucsComputePooledRackUnitEntry 3 }
+
+cucsComputePooledRackUnitAssigned OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PooledRackUnit:assigned managed
+ object property"
+ ::= { cucsComputePooledRackUnitEntry 4 }
+
+cucsComputePooledRackUnitAssignedToDn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PooledRackUnit:assignedToDn
+ managed object property"
+ ::= { cucsComputePooledRackUnitEntry 5 }
+
+cucsComputePooledRackUnitId OBJECT-TYPE
+ SYNTAX CucsComputePooledRackUnitId
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PooledRackUnit:id managed object property"
+ ::= { cucsComputePooledRackUnitEntry 6 }
+
+cucsComputePooledRackUnitOwner OBJECT-TYPE
+ SYNTAX CucsComputeOwner
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PooledRackUnit:owner managed object property"
+ ::= { cucsComputePooledRackUnitEntry 7 }
+
+cucsComputePooledRackUnitPoolableDn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PooledRackUnit:poolableDn managed
+ object property"
+ ::= { cucsComputePooledRackUnitEntry 8 }
+
+cucsComputePooledRackUnitPrevAssignedToDn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PooledRackUnit:prevAssignedToDn
+ managed object property"
+ ::= { cucsComputePooledRackUnitEntry 9 }
+
+cucsComputePooledSlotTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputePooledSlotEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PooledSlot managed object table"
+ ::= { cucsComputeObjects 30 }
+
+cucsComputePooledSlotEntry OBJECT-TYPE
+ SYNTAX CucsComputePooledSlotEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputePooledSlotTable table."
+ INDEX { cucsComputePooledSlotInstanceId }
+ ::= { cucsComputePooledSlotTable 1 }
+
+CucsComputePooledSlotEntry ::= SEQUENCE {
+ cucsComputePooledSlotInstanceId CucsManagedObjectId,
+ cucsComputePooledSlotDn CucsManagedObjectDn,
+ cucsComputePooledSlotRn SnmpAdminString,
+ cucsComputePooledSlotAssigned TruthValue,
+ cucsComputePooledSlotAssignedToDn SnmpAdminString,
+ cucsComputePooledSlotChassisId Gauge32,
+ cucsComputePooledSlotOwner CucsComputeOwner,
+ cucsComputePooledSlotPoolableDn SnmpAdminString,
+ cucsComputePooledSlotPrevAssignedToDn SnmpAdminString,
+ cucsComputePooledSlotSlotId CucsComputePooledSlotSlotId
+}
+
+cucsComputePooledSlotInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputePooledSlotEntry 1 }
+
+cucsComputePooledSlotDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PooledSlot:dn managed object property"
+ ::= { cucsComputePooledSlotEntry 2 }
+
+cucsComputePooledSlotRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PooledSlot:rn managed object property"
+ ::= { cucsComputePooledSlotEntry 3 }
+
+cucsComputePooledSlotAssigned OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PooledSlot:assigned managed object property"
+ ::= { cucsComputePooledSlotEntry 4 }
+
+cucsComputePooledSlotAssignedToDn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PooledSlot:assignedToDn managed
+ object property"
+ ::= { cucsComputePooledSlotEntry 5 }
+
+cucsComputePooledSlotChassisId OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PooledSlot:chassisId managed object property"
+ ::= { cucsComputePooledSlotEntry 6 }
+
+cucsComputePooledSlotOwner OBJECT-TYPE
+ SYNTAX CucsComputeOwner
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PooledSlot:owner managed object property"
+ ::= { cucsComputePooledSlotEntry 7 }
+
+cucsComputePooledSlotPoolableDn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PooledSlot:poolableDn managed object property"
+ ::= { cucsComputePooledSlotEntry 8 }
+
+cucsComputePooledSlotPrevAssignedToDn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PooledSlot:prevAssignedToDn
+ managed object property"
+ ::= { cucsComputePooledSlotEntry 9 }
+
+cucsComputePooledSlotSlotId OBJECT-TYPE
+ SYNTAX CucsComputePooledSlotSlotId
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PooledSlot:slotId managed object property"
+ ::= { cucsComputePooledSlotEntry 10 }
+
+cucsComputePoolingPolicyTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputePoolingPolicyEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PoolingPolicy managed object table"
+ ::= { cucsComputeObjects 31 }
+
+cucsComputePoolingPolicyEntry OBJECT-TYPE
+ SYNTAX CucsComputePoolingPolicyEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputePoolingPolicyTable table."
+ INDEX { cucsComputePoolingPolicyInstanceId }
+ ::= { cucsComputePoolingPolicyTable 1 }
+
+CucsComputePoolingPolicyEntry ::= SEQUENCE {
+ cucsComputePoolingPolicyInstanceId CucsManagedObjectId,
+ cucsComputePoolingPolicyDn CucsManagedObjectDn,
+ cucsComputePoolingPolicyRn SnmpAdminString,
+ cucsComputePoolingPolicyDescr SnmpAdminString,
+ cucsComputePoolingPolicyIntId SnmpAdminString,
+ cucsComputePoolingPolicyName SnmpAdminString,
+ cucsComputePoolingPolicyPoolDn SnmpAdminString,
+ cucsComputePoolingPolicyQualifier SnmpAdminString,
+ cucsComputePoolingPolicyPolicyLevel Gauge32,
+ cucsComputePoolingPolicyPolicyOwner CucsPolicyPolicyOwner
+}
+
+cucsComputePoolingPolicyInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputePoolingPolicyEntry 1 }
+
+cucsComputePoolingPolicyDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PoolingPolicy:dn managed object property"
+ ::= { cucsComputePoolingPolicyEntry 2 }
+
+cucsComputePoolingPolicyRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PoolingPolicy:rn managed object property"
+ ::= { cucsComputePoolingPolicyEntry 3 }
+
+cucsComputePoolingPolicyDescr OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PoolingPolicy:descr managed object property"
+ ::= { cucsComputePoolingPolicyEntry 4 }
+
+cucsComputePoolingPolicyIntId OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PoolingPolicy:intId managed object property"
+ ::= { cucsComputePoolingPolicyEntry 5 }
+
+cucsComputePoolingPolicyName OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PoolingPolicy:name managed object property"
+ ::= { cucsComputePoolingPolicyEntry 6 }
+
+cucsComputePoolingPolicyPoolDn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PoolingPolicy:poolDn managed object property"
+ ::= { cucsComputePoolingPolicyEntry 7 }
+
+cucsComputePoolingPolicyQualifier OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PoolingPolicy:qualifier managed
+ object property"
+ ::= { cucsComputePoolingPolicyEntry 8 }
+
+cucsComputePoolingPolicyPolicyLevel OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PoolingPolicy:policyLevel managed
+ object property"
+ ::= { cucsComputePoolingPolicyEntry 9 }
+
+cucsComputePoolingPolicyPolicyOwner OBJECT-TYPE
+ SYNTAX CucsPolicyPolicyOwner
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PoolingPolicy:policyOwner managed
+ object property"
+ ::= { cucsComputePoolingPolicyEntry 10 }
+
+cucsComputePsuControlTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputePsuControlEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PsuControl managed object table"
+ ::= { cucsComputeObjects 32 }
+
+cucsComputePsuControlEntry OBJECT-TYPE
+ SYNTAX CucsComputePsuControlEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputePsuControlTable table."
+ INDEX { cucsComputePsuControlInstanceId }
+ ::= { cucsComputePsuControlTable 1 }
+
+CucsComputePsuControlEntry ::= SEQUENCE {
+ cucsComputePsuControlInstanceId CucsManagedObjectId,
+ cucsComputePsuControlDn CucsManagedObjectDn,
+ cucsComputePsuControlRn SnmpAdminString,
+ cucsComputePsuControlClusterState CucsComputePsuClusterState,
+ cucsComputePsuControlDescr SnmpAdminString,
+ cucsComputePsuControlInputPowerState CucsEquipmentSensorThresholdStatus,
+ cucsComputePsuControlIntId SnmpAdminString,
+ cucsComputePsuControlName SnmpAdminString,
+ cucsComputePsuControlOperQualifier CucsComputePsuRedundancyOperQualifier,
+ cucsComputePsuControlOperState CucsComputePsuRedundancyOperState,
+ cucsComputePsuControlOutputPowerState CucsEquipmentSensorThresholdStatus,
+ cucsComputePsuControlRedundancy CucsComputePsuControlRedundancy,
+ cucsComputePsuControlPolicyLevel Gauge32,
+ cucsComputePsuControlPolicyOwner CucsPolicyPolicyOwner
+}
+
+cucsComputePsuControlInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputePsuControlEntry 1 }
+
+cucsComputePsuControlDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PsuControl:dn managed object property"
+ ::= { cucsComputePsuControlEntry 2 }
+
+cucsComputePsuControlRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PsuControl:rn managed object property"
+ ::= { cucsComputePsuControlEntry 3 }
+
+cucsComputePsuControlClusterState OBJECT-TYPE
+ SYNTAX CucsComputePsuClusterState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PsuControl:clusterState managed
+ object property"
+ ::= { cucsComputePsuControlEntry 4 }
+
+cucsComputePsuControlDescr OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PsuControl:descr managed object property"
+ ::= { cucsComputePsuControlEntry 5 }
+
+cucsComputePsuControlInputPowerState OBJECT-TYPE
+ SYNTAX CucsEquipmentSensorThresholdStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PsuControl:inputPowerState managed
+ object property"
+ ::= { cucsComputePsuControlEntry 6 }
+
+cucsComputePsuControlIntId OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PsuControl:intId managed object property"
+ ::= { cucsComputePsuControlEntry 7 }
+
+cucsComputePsuControlName OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PsuControl:name managed object property"
+ ::= { cucsComputePsuControlEntry 8 }
+
+cucsComputePsuControlOperQualifier OBJECT-TYPE
+ SYNTAX CucsComputePsuRedundancyOperQualifier
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PsuControl:operQualifier managed
+ object property"
+ ::= { cucsComputePsuControlEntry 9 }
+
+cucsComputePsuControlOperState OBJECT-TYPE
+ SYNTAX CucsComputePsuRedundancyOperState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PsuControl:operState managed object property"
+ ::= { cucsComputePsuControlEntry 10 }
+
+cucsComputePsuControlOutputPowerState OBJECT-TYPE
+ SYNTAX CucsEquipmentSensorThresholdStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PsuControl:outputPowerState
+ managed object property"
+ ::= { cucsComputePsuControlEntry 11 }
+
+cucsComputePsuControlRedundancy OBJECT-TYPE
+ SYNTAX CucsComputePsuControlRedundancy
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PsuControl:redundancy managed object property"
+ ::= { cucsComputePsuControlEntry 12 }
+
+cucsComputePsuControlPolicyLevel OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PsuControl:policyLevel managed object property"
+ ::= { cucsComputePsuControlEntry 13 }
+
+cucsComputePsuControlPolicyOwner OBJECT-TYPE
+ SYNTAX CucsPolicyPolicyOwner
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PsuControl:policyOwner managed object property"
+ ::= { cucsComputePsuControlEntry 14 }
+
+cucsComputePsuPolicyTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputePsuPolicyEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PsuPolicy managed object table"
+ ::= { cucsComputeObjects 33 }
+
+cucsComputePsuPolicyEntry OBJECT-TYPE
+ SYNTAX CucsComputePsuPolicyEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputePsuPolicyTable table."
+ INDEX { cucsComputePsuPolicyInstanceId }
+ ::= { cucsComputePsuPolicyTable 1 }
+
+CucsComputePsuPolicyEntry ::= SEQUENCE {
+ cucsComputePsuPolicyInstanceId CucsManagedObjectId,
+ cucsComputePsuPolicyDn CucsManagedObjectDn,
+ cucsComputePsuPolicyRn SnmpAdminString,
+ cucsComputePsuPolicyDescr SnmpAdminString,
+ cucsComputePsuPolicyIntId SnmpAdminString,
+ cucsComputePsuPolicyName SnmpAdminString,
+ cucsComputePsuPolicyRedundancy CucsComputePsuRedundancy,
+ cucsComputePsuPolicyPolicyLevel Gauge32,
+ cucsComputePsuPolicyPolicyOwner CucsPolicyPolicyOwner
+}
+
+cucsComputePsuPolicyInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputePsuPolicyEntry 1 }
+
+cucsComputePsuPolicyDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PsuPolicy:dn managed object property"
+ ::= { cucsComputePsuPolicyEntry 2 }
+
+cucsComputePsuPolicyRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PsuPolicy:rn managed object property"
+ ::= { cucsComputePsuPolicyEntry 3 }
+
+cucsComputePsuPolicyDescr OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PsuPolicy:descr managed object property"
+ ::= { cucsComputePsuPolicyEntry 4 }
+
+cucsComputePsuPolicyIntId OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PsuPolicy:intId managed object property"
+ ::= { cucsComputePsuPolicyEntry 5 }
+
+cucsComputePsuPolicyName OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PsuPolicy:name managed object property"
+ ::= { cucsComputePsuPolicyEntry 6 }
+
+cucsComputePsuPolicyRedundancy OBJECT-TYPE
+ SYNTAX CucsComputePsuRedundancy
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PsuPolicy:redundancy managed object property"
+ ::= { cucsComputePsuPolicyEntry 7 }
+
+cucsComputePsuPolicyPolicyLevel OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PsuPolicy:policyLevel managed object property"
+ ::= { cucsComputePsuPolicyEntry 8 }
+
+cucsComputePsuPolicyPolicyOwner OBJECT-TYPE
+ SYNTAX CucsPolicyPolicyOwner
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:PsuPolicy:policyOwner managed object property"
+ ::= { cucsComputePsuPolicyEntry 9 }
+
+cucsComputeQualTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputeQualEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Qual managed object table"
+ ::= { cucsComputeObjects 34 }
+
+cucsComputeQualEntry OBJECT-TYPE
+ SYNTAX CucsComputeQualEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputeQualTable table."
+ INDEX { cucsComputeQualInstanceId }
+ ::= { cucsComputeQualTable 1 }
+
+CucsComputeQualEntry ::= SEQUENCE {
+ cucsComputeQualInstanceId CucsManagedObjectId,
+ cucsComputeQualDn CucsManagedObjectDn,
+ cucsComputeQualRn SnmpAdminString,
+ cucsComputeQualDescr SnmpAdminString,
+ cucsComputeQualIntId SnmpAdminString,
+ cucsComputeQualName SnmpAdminString,
+ cucsComputeQualPolicyLevel Gauge32,
+ cucsComputeQualPolicyOwner CucsPolicyPolicyOwner
+}
+
+cucsComputeQualInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputeQualEntry 1 }
+
+cucsComputeQualDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Qual:dn managed object property"
+ ::= { cucsComputeQualEntry 2 }
+
+cucsComputeQualRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Qual:rn managed object property"
+ ::= { cucsComputeQualEntry 3 }
+
+cucsComputeQualDescr OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Qual:descr managed object property"
+ ::= { cucsComputeQualEntry 4 }
+
+cucsComputeQualIntId OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Qual:intId managed object property"
+ ::= { cucsComputeQualEntry 5 }
+
+cucsComputeQualName OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Qual:name managed object property"
+ ::= { cucsComputeQualEntry 6 }
+
+cucsComputeQualPolicyLevel OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Qual:policyLevel managed object property"
+ ::= { cucsComputeQualEntry 7 }
+
+cucsComputeQualPolicyOwner OBJECT-TYPE
+ SYNTAX CucsPolicyPolicyOwner
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:Qual:policyOwner managed object property"
+ ::= { cucsComputeQualEntry 8 }
+
+cucsComputeRackQualTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputeRackQualEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackQual managed object table"
+ ::= { cucsComputeObjects 43 }
+
+cucsComputeRackQualEntry OBJECT-TYPE
+ SYNTAX CucsComputeRackQualEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputeRackQualTable table."
+ INDEX { cucsComputeRackQualInstanceId }
+ ::= { cucsComputeRackQualTable 1 }
+
+CucsComputeRackQualEntry ::= SEQUENCE {
+ cucsComputeRackQualInstanceId CucsManagedObjectId,
+ cucsComputeRackQualDn CucsManagedObjectDn,
+ cucsComputeRackQualRn SnmpAdminString,
+ cucsComputeRackQualMaxId CucsComputeRackQualMaxId,
+ cucsComputeRackQualMinId CucsComputeRackQualMinId
+}
+
+cucsComputeRackQualInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputeRackQualEntry 1 }
+
+cucsComputeRackQualDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackQual:dn managed object property"
+ ::= { cucsComputeRackQualEntry 2 }
+
+cucsComputeRackQualRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackQual:rn managed object property"
+ ::= { cucsComputeRackQualEntry 3 }
+
+cucsComputeRackQualMaxId OBJECT-TYPE
+ SYNTAX CucsComputeRackQualMaxId
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackQual:maxId managed object property"
+ ::= { cucsComputeRackQualEntry 4 }
+
+cucsComputeRackQualMinId OBJECT-TYPE
+ SYNTAX CucsComputeRackQualMinId
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackQual:minId managed object property"
+ ::= { cucsComputeRackQualEntry 5 }
+
+cucsComputeRackUnitTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputeRackUnitEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnit managed object table"
+ ::= { cucsComputeObjects 35 }
+
+cucsComputeRackUnitEntry OBJECT-TYPE
+ SYNTAX CucsComputeRackUnitEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputeRackUnitTable table."
+ INDEX { cucsComputeRackUnitInstanceId }
+ ::= { cucsComputeRackUnitTable 1 }
+
+CucsComputeRackUnitEntry ::= SEQUENCE {
+ cucsComputeRackUnitInstanceId CucsManagedObjectId,
+ cucsComputeRackUnitDn CucsManagedObjectDn,
+ cucsComputeRackUnitRn SnmpAdminString,
+ cucsComputeRackUnitAdminPower CucsComputeAdminPowerState,
+ cucsComputeRackUnitAdminState CucsComputeAdminState,
+ cucsComputeRackUnitAssignedToDn SnmpAdminString,
+ cucsComputeRackUnitAssociation CucsComputeAssociation,
+ cucsComputeRackUnitAvailability CucsComputeAvailability,
+ cucsComputeRackUnitAvailableMemory Gauge32,
+ cucsComputeRackUnitCheckPoint CucsComputeCheckPoint,
+ cucsComputeRackUnitConnPath CucsEquipmentConnectionStatus,
+ cucsComputeRackUnitConnStatus CucsEquipmentConnectionStatus,
+ cucsComputeRackUnitDescr SnmpAdminString,
+ cucsComputeRackUnitDiscovery CucsComputeDiscovery,
+ cucsComputeRackUnitFltAggr Unsigned64,
+ cucsComputeRackUnitFsmDescr SnmpAdminString,
+ cucsComputeRackUnitFsmFlags SnmpAdminString,
+ cucsComputeRackUnitFsmPrev SnmpAdminString,
+ cucsComputeRackUnitFsmProgr Gauge32,
+ cucsComputeRackUnitFsmRmtInvErrCode Gauge32,
+ cucsComputeRackUnitFsmRmtInvErrDescr SnmpAdminString,
+ cucsComputeRackUnitFsmRmtInvRslt CucsConditionRemoteInvRslt,
+ cucsComputeRackUnitFsmStageDescr SnmpAdminString,
+ cucsComputeRackUnitFsmStamp DateAndTime,
+ cucsComputeRackUnitFsmStatus SnmpAdminString,
+ cucsComputeRackUnitFsmTry Gauge32,
+ cucsComputeRackUnitId CucsComputeRackUnitId,
+ cucsComputeRackUnitIntId SnmpAdminString,
+ cucsComputeRackUnitLc CucsComputeAdminTrigger,
+ cucsComputeRackUnitLcTs DateAndTime,
+ cucsComputeRackUnitManagingInst CucsNetworkSwitchId,
+ cucsComputeRackUnitModel SnmpAdminString,
+ cucsComputeRackUnitName SnmpAdminString,
+ cucsComputeRackUnitNumOfAdaptors Gauge32,
+ cucsComputeRackUnitNumOfCores Gauge32,
+ cucsComputeRackUnitNumOfCpus Gauge32,
+ cucsComputeRackUnitNumOfEthHostIfs Gauge32,
+ cucsComputeRackUnitNumOfFcHostIfs Gauge32,
+ cucsComputeRackUnitNumOfThreads Gauge32,
+ cucsComputeRackUnitOperPower CucsEquipmentPowerState,
+ cucsComputeRackUnitOperQualifier CucsComputeIssues,
+ cucsComputeRackUnitOperState CucsLsOperState,
+ cucsComputeRackUnitOperability CucsEquipmentOperability,
+ cucsComputeRackUnitOriginalUuid SnmpAdminString,
+ cucsComputeRackUnitPresence CucsEquipmentSlotStatus,
+ cucsComputeRackUnitRevision SnmpAdminString,
+ cucsComputeRackUnitSerial SnmpAdminString,
+ cucsComputeRackUnitServerId SnmpAdminString,
+ cucsComputeRackUnitTotalMemory Gauge32,
+ cucsComputeRackUnitUuid SnmpAdminString,
+ cucsComputeRackUnitVendor SnmpAdminString,
+ cucsComputeRackUnitVersionHolder TruthValue,
+ cucsComputeRackUnitNumOfCoresEnabled Gauge32,
+ cucsComputeRackUnitLowVoltageMemory CucsComputePhysicalLowVoltageMemory,
+ cucsComputeRackUnitMemorySpeed Gauge32,
+ cucsComputeRackUnitUsrLbl SnmpAdminString,
+ cucsComputeRackUnitMfgTime DateAndTime,
+ cucsComputeRackUnitPartNumber SnmpAdminString,
+ cucsComputeRackUnitVid SnmpAdminString,
+ cucsComputeRackUnitPolicyLevel Gauge32,
+ cucsComputeRackUnitPolicyOwner CucsPolicyPolicyOwner,
+ cucsComputeRackUnitLocalId SnmpAdminString,
+ cucsComputeRackUnitOperPwrTransSrc CucsComputePowerTransitionSrc,
+ cucsComputeRackUnitDiscoveryStatus CucsEquipmentConnectionStatus,
+ cucsComputeRackUnitNumOf40GAdaptorsWithOldFw Gauge32,
+ cucsComputeRackUnitNumOf40GAdaptorsWithUnknownFw Gauge32,
+ cucsComputeRackUnitFanSpeedConfigStatus SnmpAdminString,
+ cucsComputeRackUnitFanSpeedPolicyFault CucsEquipmentFanSpeedPolicyFault
+}
+
+cucsComputeRackUnitInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputeRackUnitEntry 1 }
+
+cucsComputeRackUnitDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnit:dn managed object property"
+ ::= { cucsComputeRackUnitEntry 2 }
+
+cucsComputeRackUnitRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnit:rn managed object property"
+ ::= { cucsComputeRackUnitEntry 3 }
+
+cucsComputeRackUnitAdminPower OBJECT-TYPE
+ SYNTAX CucsComputeAdminPowerState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnit:adminPower managed object property"
+ ::= { cucsComputeRackUnitEntry 4 }
+
+cucsComputeRackUnitAdminState OBJECT-TYPE
+ SYNTAX CucsComputeAdminState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnit:adminState managed object property"
+ ::= { cucsComputeRackUnitEntry 5 }
+
+cucsComputeRackUnitAssignedToDn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnit:assignedToDn managed object property"
+ ::= { cucsComputeRackUnitEntry 6 }
+
+cucsComputeRackUnitAssociation OBJECT-TYPE
+ SYNTAX CucsComputeAssociation
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnit:association managed object property"
+ ::= { cucsComputeRackUnitEntry 7 }
+
+cucsComputeRackUnitAvailability OBJECT-TYPE
+ SYNTAX CucsComputeAvailability
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnit:availability managed object property"
+ ::= { cucsComputeRackUnitEntry 8 }
+
+cucsComputeRackUnitAvailableMemory OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnit:availableMemory managed
+ object property"
+ ::= { cucsComputeRackUnitEntry 9 }
+
+cucsComputeRackUnitCheckPoint OBJECT-TYPE
+ SYNTAX CucsComputeCheckPoint
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnit:checkPoint managed object property"
+ ::= { cucsComputeRackUnitEntry 10 }
+
+cucsComputeRackUnitConnPath OBJECT-TYPE
+ SYNTAX CucsEquipmentConnectionStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnit:connPath managed object property"
+ ::= { cucsComputeRackUnitEntry 11 }
+
+cucsComputeRackUnitConnStatus OBJECT-TYPE
+ SYNTAX CucsEquipmentConnectionStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnit:connStatus managed object property"
+ ::= { cucsComputeRackUnitEntry 12 }
+
+cucsComputeRackUnitDescr OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnit:descr managed object property"
+ ::= { cucsComputeRackUnitEntry 13 }
+
+cucsComputeRackUnitDiscovery OBJECT-TYPE
+ SYNTAX CucsComputeDiscovery
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnit:discovery managed object property"
+ ::= { cucsComputeRackUnitEntry 14 }
+
+cucsComputeRackUnitFltAggr OBJECT-TYPE
+ SYNTAX Unsigned64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnit:fltAggr managed object property"
+ ::= { cucsComputeRackUnitEntry 15 }
+
+cucsComputeRackUnitFsmDescr OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnit:fsmDescr managed object property"
+ ::= { cucsComputeRackUnitEntry 16 }
+
+cucsComputeRackUnitFsmFlags OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnit:fsmFlags managed object property"
+ ::= { cucsComputeRackUnitEntry 17 }
+
+cucsComputeRackUnitFsmPrev OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnit:fsmPrev managed object property"
+ ::= { cucsComputeRackUnitEntry 18 }
+
+cucsComputeRackUnitFsmProgr OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnit:fsmProgr managed object property"
+ ::= { cucsComputeRackUnitEntry 19 }
+
+cucsComputeRackUnitFsmRmtInvErrCode OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnit:fsmRmtInvErrCode managed
+ object property"
+ ::= { cucsComputeRackUnitEntry 20 }
+
+cucsComputeRackUnitFsmRmtInvErrDescr OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnit:fsmRmtInvErrDescr managed
+ object property"
+ ::= { cucsComputeRackUnitEntry 21 }
+
+cucsComputeRackUnitFsmRmtInvRslt OBJECT-TYPE
+ SYNTAX CucsConditionRemoteInvRslt
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnit:fsmRmtInvRslt managed object property"
+ ::= { cucsComputeRackUnitEntry 22 }
+
+cucsComputeRackUnitFsmStageDescr OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnit:fsmStageDescr managed object property"
+ ::= { cucsComputeRackUnitEntry 23 }
+
+cucsComputeRackUnitFsmStamp OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnit:fsmStamp managed object property"
+ ::= { cucsComputeRackUnitEntry 24 }
+
+cucsComputeRackUnitFsmStatus OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnit:fsmStatus managed object property"
+ ::= { cucsComputeRackUnitEntry 25 }
+
+cucsComputeRackUnitFsmTry OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnit:fsmTry managed object property"
+ ::= { cucsComputeRackUnitEntry 26 }
+
+cucsComputeRackUnitId OBJECT-TYPE
+ SYNTAX CucsComputeRackUnitId
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnit:id managed object property"
+ ::= { cucsComputeRackUnitEntry 27 }
+
+cucsComputeRackUnitIntId OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnit:intId managed object property"
+ ::= { cucsComputeRackUnitEntry 28 }
+
+cucsComputeRackUnitLc OBJECT-TYPE
+ SYNTAX CucsComputeAdminTrigger
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnit:lc managed object property"
+ ::= { cucsComputeRackUnitEntry 29 }
+
+cucsComputeRackUnitLcTs OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnit:lcTs managed object property"
+ ::= { cucsComputeRackUnitEntry 30 }
+
+cucsComputeRackUnitManagingInst OBJECT-TYPE
+ SYNTAX CucsNetworkSwitchId
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnit:managingInst managed object property"
+ ::= { cucsComputeRackUnitEntry 31 }
+
+cucsComputeRackUnitModel OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnit:model managed object property"
+ ::= { cucsComputeRackUnitEntry 32 }
+
+cucsComputeRackUnitName OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnit:name managed object property"
+ ::= { cucsComputeRackUnitEntry 33 }
+
+cucsComputeRackUnitNumOfAdaptors OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnit:numOfAdaptors managed object property"
+ ::= { cucsComputeRackUnitEntry 34 }
+
+cucsComputeRackUnitNumOfCores OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnit:numOfCores managed object property"
+ ::= { cucsComputeRackUnitEntry 35 }
+
+cucsComputeRackUnitNumOfCpus OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnit:numOfCpus managed object property"
+ ::= { cucsComputeRackUnitEntry 36 }
+
+cucsComputeRackUnitNumOfEthHostIfs OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnit:numOfEthHostIfs managed
+ object property"
+ ::= { cucsComputeRackUnitEntry 37 }
+
+cucsComputeRackUnitNumOfFcHostIfs OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnit:numOfFcHostIfs managed
+ object property"
+ ::= { cucsComputeRackUnitEntry 38 }
+
+cucsComputeRackUnitNumOfThreads OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnit:numOfThreads managed object property"
+ ::= { cucsComputeRackUnitEntry 39 }
+
+cucsComputeRackUnitOperPower OBJECT-TYPE
+ SYNTAX CucsEquipmentPowerState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnit:operPower managed object property"
+ ::= { cucsComputeRackUnitEntry 40 }
+
+cucsComputeRackUnitOperQualifier OBJECT-TYPE
+ SYNTAX CucsComputeIssues
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnit:operQualifier managed object property"
+ ::= { cucsComputeRackUnitEntry 41 }
+
+cucsComputeRackUnitOperState OBJECT-TYPE
+ SYNTAX CucsLsOperState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnit:operState managed object property"
+ ::= { cucsComputeRackUnitEntry 42 }
+
+cucsComputeRackUnitOperability OBJECT-TYPE
+ SYNTAX CucsEquipmentOperability
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnit:operability managed object property"
+ ::= { cucsComputeRackUnitEntry 43 }
+
+cucsComputeRackUnitOriginalUuid OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnit:originalUuid managed object property"
+ ::= { cucsComputeRackUnitEntry 44 }
+
+cucsComputeRackUnitPresence OBJECT-TYPE
+ SYNTAX CucsEquipmentSlotStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnit:presence managed object property"
+ ::= { cucsComputeRackUnitEntry 45 }
+
+cucsComputeRackUnitRevision OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnit:revision managed object property"
+ ::= { cucsComputeRackUnitEntry 46 }
+
+cucsComputeRackUnitSerial OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnit:serial managed object property"
+ ::= { cucsComputeRackUnitEntry 47 }
+
+cucsComputeRackUnitServerId OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnit:serverId managed object property"
+ ::= { cucsComputeRackUnitEntry 48 }
+
+cucsComputeRackUnitTotalMemory OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnit:totalMemory managed object property"
+ ::= { cucsComputeRackUnitEntry 49 }
+
+cucsComputeRackUnitUuid OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnit:uuid managed object property"
+ ::= { cucsComputeRackUnitEntry 50 }
+
+cucsComputeRackUnitVendor OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnit:vendor managed object property"
+ ::= { cucsComputeRackUnitEntry 51 }
+
+cucsComputeRackUnitVersionHolder OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnit:versionHolder managed object property"
+ ::= { cucsComputeRackUnitEntry 52 }
+
+cucsComputeRackUnitNumOfCoresEnabled OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnit:numOfCoresEnabled managed
+ object property"
+ ::= { cucsComputeRackUnitEntry 53 }
+
+cucsComputeRackUnitLowVoltageMemory OBJECT-TYPE
+ SYNTAX CucsComputePhysicalLowVoltageMemory
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnit:lowVoltageMemory managed
+ object property"
+ ::= { cucsComputeRackUnitEntry 54 }
+
+cucsComputeRackUnitMemorySpeed OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnit:memorySpeed managed object property"
+ ::= { cucsComputeRackUnitEntry 55 }
+
+cucsComputeRackUnitUsrLbl OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnit:usrLbl managed object property"
+ ::= { cucsComputeRackUnitEntry 56 }
+
+cucsComputeRackUnitMfgTime OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnit:mfgTime managed object property"
+ ::= { cucsComputeRackUnitEntry 57 }
+
+cucsComputeRackUnitPartNumber OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnit:partNumber managed object property"
+ ::= { cucsComputeRackUnitEntry 58 }
+
+cucsComputeRackUnitVid OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnit:vid managed object property"
+ ::= { cucsComputeRackUnitEntry 59 }
+
+cucsComputeRackUnitPolicyLevel OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnit:policyLevel managed object property"
+ ::= { cucsComputeRackUnitEntry 60 }
+
+cucsComputeRackUnitPolicyOwner OBJECT-TYPE
+ SYNTAX CucsPolicyPolicyOwner
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnit:policyOwner managed object property"
+ ::= { cucsComputeRackUnitEntry 61 }
+
+cucsComputeRackUnitLocalId OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnit:localId managed object property"
+ ::= { cucsComputeRackUnitEntry 62 }
+
+cucsComputeRackUnitOperPwrTransSrc OBJECT-TYPE
+ SYNTAX CucsComputePowerTransitionSrc
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnit:operPwrTransSrc managed
+ object property"
+ ::= { cucsComputeRackUnitEntry 63 }
+
+cucsComputeRackUnitDiscoveryStatus OBJECT-TYPE
+ SYNTAX CucsEquipmentConnectionStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnit:discoveryStatus managed
+ object property"
+ ::= { cucsComputeRackUnitEntry 64 }
+
+cucsComputeRackUnitNumOf40GAdaptorsWithOldFw OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnit:numOf40GAdaptorsWithOldFw
+ managed object property"
+ ::= { cucsComputeRackUnitEntry 66 }
+
+cucsComputeRackUnitNumOf40GAdaptorsWithUnknownFw OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnit:numOf40GAdaptorsWithUnknownFw
+ managed object property"
+ ::= { cucsComputeRackUnitEntry 67 }
+
+cucsComputeRackUnitFanSpeedConfigStatus OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnit:fanSpeedConfigStatus
+ managed object property"
+ ::= { cucsComputeRackUnitEntry 68 }
+
+cucsComputeRackUnitFanSpeedPolicyFault OBJECT-TYPE
+ SYNTAX CucsEquipmentFanSpeedPolicyFault
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnit:fanSpeedPolicyFault
+ managed object property"
+ ::= { cucsComputeRackUnitEntry 69 }
+
+cucsComputeRackUnitFsmTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputeRackUnitFsmEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitFsm managed object table"
+ ::= { cucsComputeObjects 52 }
+
+cucsComputeRackUnitFsmEntry OBJECT-TYPE
+ SYNTAX CucsComputeRackUnitFsmEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputeRackUnitFsmTable table."
+ INDEX { cucsComputeRackUnitFsmInstanceId }
+ ::= { cucsComputeRackUnitFsmTable 1 }
+
+CucsComputeRackUnitFsmEntry ::= SEQUENCE {
+ cucsComputeRackUnitFsmInstanceId CucsManagedObjectId,
+ cucsComputeRackUnitFsmDn CucsManagedObjectDn,
+ cucsComputeRackUnitFsmRn SnmpAdminString,
+ cucsComputeRackUnitFsmCompletionTime DateAndTime,
+ cucsComputeRackUnitFsmCurrentFsm CucsComputeRackUnitFsmCurrentFsm,
+ cucsComputeRackUnitFsmDescrData SnmpAdminString,
+ cucsComputeRackUnitFsmFsmStatus CucsFsmFsmStageStatus,
+ cucsComputeRackUnitFsmProgress Gauge32,
+ cucsComputeRackUnitFsmRmtErrCode Gauge32,
+ cucsComputeRackUnitFsmRmtErrDescr SnmpAdminString,
+ cucsComputeRackUnitFsmRmtRslt CucsConditionRemoteInvRslt
+}
+
+cucsComputeRackUnitFsmInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputeRackUnitFsmEntry 1 }
+
+cucsComputeRackUnitFsmDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitFsm:dn managed object property"
+ ::= { cucsComputeRackUnitFsmEntry 2 }
+
+cucsComputeRackUnitFsmRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitFsm:rn managed object property"
+ ::= { cucsComputeRackUnitFsmEntry 3 }
+
+cucsComputeRackUnitFsmCompletionTime OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitFsm:completionTime managed
+ object property"
+ ::= { cucsComputeRackUnitFsmEntry 4 }
+
+cucsComputeRackUnitFsmCurrentFsm OBJECT-TYPE
+ SYNTAX CucsComputeRackUnitFsmCurrentFsm
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitFsm:currentFsm managed object property"
+ ::= { cucsComputeRackUnitFsmEntry 5 }
+
+cucsComputeRackUnitFsmDescrData OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitFsm:descr managed object property"
+ ::= { cucsComputeRackUnitFsmEntry 6 }
+
+cucsComputeRackUnitFsmFsmStatus OBJECT-TYPE
+ SYNTAX CucsFsmFsmStageStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitFsm:fsmStatus managed object property"
+ ::= { cucsComputeRackUnitFsmEntry 7 }
+
+cucsComputeRackUnitFsmProgress OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitFsm:progress managed object property"
+ ::= { cucsComputeRackUnitFsmEntry 8 }
+
+cucsComputeRackUnitFsmRmtErrCode OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitFsm:rmtErrCode managed object property"
+ ::= { cucsComputeRackUnitFsmEntry 9 }
+
+cucsComputeRackUnitFsmRmtErrDescr OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitFsm:rmtErrDescr managed
+ object property"
+ ::= { cucsComputeRackUnitFsmEntry 10 }
+
+cucsComputeRackUnitFsmRmtRslt OBJECT-TYPE
+ SYNTAX CucsConditionRemoteInvRslt
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitFsm:rmtRslt managed object property"
+ ::= { cucsComputeRackUnitFsmEntry 11 }
+
+cucsComputeRackUnitFsmStageTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputeRackUnitFsmStageEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitFsmStage managed object table"
+ ::= { cucsComputeObjects 53 }
+
+cucsComputeRackUnitFsmStageEntry OBJECT-TYPE
+ SYNTAX CucsComputeRackUnitFsmStageEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputeRackUnitFsmStageTable table."
+ INDEX { cucsComputeRackUnitFsmStageInstanceId }
+ ::= { cucsComputeRackUnitFsmStageTable 1 }
+
+CucsComputeRackUnitFsmStageEntry ::= SEQUENCE {
+ cucsComputeRackUnitFsmStageInstanceId CucsManagedObjectId,
+ cucsComputeRackUnitFsmStageDn CucsManagedObjectDn,
+ cucsComputeRackUnitFsmStageRn SnmpAdminString,
+ cucsComputeRackUnitFsmStageDescrData SnmpAdminString,
+ cucsComputeRackUnitFsmStageLastUpdateTime DateAndTime,
+ cucsComputeRackUnitFsmStageName CucsComputeRackUnitFsmStageName,
+ cucsComputeRackUnitFsmStageOrder Gauge32,
+ cucsComputeRackUnitFsmStageRetry Gauge32,
+ cucsComputeRackUnitFsmStageStageStatus CucsFsmFsmStageStatus
+}
+
+cucsComputeRackUnitFsmStageInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputeRackUnitFsmStageEntry 1 }
+
+cucsComputeRackUnitFsmStageDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitFsmStage:dn managed object property"
+ ::= { cucsComputeRackUnitFsmStageEntry 2 }
+
+cucsComputeRackUnitFsmStageRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitFsmStage:rn managed object property"
+ ::= { cucsComputeRackUnitFsmStageEntry 3 }
+
+cucsComputeRackUnitFsmStageDescrData OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitFsmStage:descr managed object property"
+ ::= { cucsComputeRackUnitFsmStageEntry 4 }
+
+cucsComputeRackUnitFsmStageLastUpdateTime OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitFsmStage:lastUpdateTime
+ managed object property"
+ ::= { cucsComputeRackUnitFsmStageEntry 5 }
+
+cucsComputeRackUnitFsmStageName OBJECT-TYPE
+ SYNTAX CucsComputeRackUnitFsmStageName
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitFsmStage:name managed object property"
+ ::= { cucsComputeRackUnitFsmStageEntry 6 }
+
+cucsComputeRackUnitFsmStageOrder OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitFsmStage:order managed object property"
+ ::= { cucsComputeRackUnitFsmStageEntry 7 }
+
+cucsComputeRackUnitFsmStageRetry OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitFsmStage:retry managed object property"
+ ::= { cucsComputeRackUnitFsmStageEntry 8 }
+
+cucsComputeRackUnitFsmStageStageStatus OBJECT-TYPE
+ SYNTAX CucsFsmFsmStageStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitFsmStage:stageStatus
+ managed object property"
+ ::= { cucsComputeRackUnitFsmStageEntry 9 }
+
+cucsComputeRackUnitFsmTaskTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputeRackUnitFsmTaskEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitFsmTask managed object table"
+ ::= { cucsComputeObjects 36 }
+
+cucsComputeRackUnitFsmTaskEntry OBJECT-TYPE
+ SYNTAX CucsComputeRackUnitFsmTaskEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputeRackUnitFsmTaskTable table."
+ INDEX { cucsComputeRackUnitFsmTaskInstanceId }
+ ::= { cucsComputeRackUnitFsmTaskTable 1 }
+
+CucsComputeRackUnitFsmTaskEntry ::= SEQUENCE {
+ cucsComputeRackUnitFsmTaskInstanceId CucsManagedObjectId,
+ cucsComputeRackUnitFsmTaskDn CucsManagedObjectDn,
+ cucsComputeRackUnitFsmTaskRn SnmpAdminString,
+ cucsComputeRackUnitFsmTaskCompletion CucsFsmCompletion,
+ cucsComputeRackUnitFsmTaskFlags CucsComputeRackUnitFsmTaskFlags,
+ cucsComputeRackUnitFsmTaskItem CucsComputeRackUnitFsmTaskItem,
+ cucsComputeRackUnitFsmTaskSeqId Gauge32
+}
+
+cucsComputeRackUnitFsmTaskInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputeRackUnitFsmTaskEntry 1 }
+
+cucsComputeRackUnitFsmTaskDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitFsmTask:dn managed object property"
+ ::= { cucsComputeRackUnitFsmTaskEntry 2 }
+
+cucsComputeRackUnitFsmTaskRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitFsmTask:rn managed object property"
+ ::= { cucsComputeRackUnitFsmTaskEntry 3 }
+
+cucsComputeRackUnitFsmTaskCompletion OBJECT-TYPE
+ SYNTAX CucsFsmCompletion
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitFsmTask:completion managed
+ object property"
+ ::= { cucsComputeRackUnitFsmTaskEntry 4 }
+
+cucsComputeRackUnitFsmTaskFlags OBJECT-TYPE
+ SYNTAX CucsComputeRackUnitFsmTaskFlags
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitFsmTask:flags managed object property"
+ ::= { cucsComputeRackUnitFsmTaskEntry 5 }
+
+cucsComputeRackUnitFsmTaskItem OBJECT-TYPE
+ SYNTAX CucsComputeRackUnitFsmTaskItem
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitFsmTask:item managed object property"
+ ::= { cucsComputeRackUnitFsmTaskEntry 6 }
+
+cucsComputeRackUnitFsmTaskSeqId OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitFsmTask:seqId managed object property"
+ ::= { cucsComputeRackUnitFsmTaskEntry 7 }
+
+cucsComputeRackUnitMbTempStatsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputeRackUnitMbTempStatsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitMbTempStats managed object table"
+ ::= { cucsComputeObjects 44 }
+
+cucsComputeRackUnitMbTempStatsEntry OBJECT-TYPE
+ SYNTAX CucsComputeRackUnitMbTempStatsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputeRackUnitMbTempStatsTable table."
+ INDEX { cucsComputeRackUnitMbTempStatsInstanceId }
+ ::= { cucsComputeRackUnitMbTempStatsTable 1 }
+
+CucsComputeRackUnitMbTempStatsEntry ::= SEQUENCE {
+ cucsComputeRackUnitMbTempStatsInstanceId CucsManagedObjectId,
+ cucsComputeRackUnitMbTempStatsDn CucsManagedObjectDn,
+ cucsComputeRackUnitMbTempStatsRn SnmpAdminString,
+ cucsComputeRackUnitMbTempStatsAmbientTemp INTEGER,
+ cucsComputeRackUnitMbTempStatsAmbientTempAvg INTEGER,
+ cucsComputeRackUnitMbTempStatsAmbientTempMax INTEGER,
+ cucsComputeRackUnitMbTempStatsAmbientTempMin INTEGER,
+ cucsComputeRackUnitMbTempStatsFrontTemp INTEGER,
+ cucsComputeRackUnitMbTempStatsFrontTempAvg INTEGER,
+ cucsComputeRackUnitMbTempStatsFrontTempMax INTEGER,
+ cucsComputeRackUnitMbTempStatsFrontTempMin INTEGER,
+ cucsComputeRackUnitMbTempStatsIntervals Gauge32,
+ cucsComputeRackUnitMbTempStatsIoh1Temp INTEGER,
+ cucsComputeRackUnitMbTempStatsIoh1TempAvg INTEGER,
+ cucsComputeRackUnitMbTempStatsIoh1TempMax INTEGER,
+ cucsComputeRackUnitMbTempStatsIoh1TempMin INTEGER,
+ cucsComputeRackUnitMbTempStatsIoh2Temp INTEGER,
+ cucsComputeRackUnitMbTempStatsIoh2TempAvg INTEGER,
+ cucsComputeRackUnitMbTempStatsIoh2TempMax INTEGER,
+ cucsComputeRackUnitMbTempStatsIoh2TempMin INTEGER,
+ cucsComputeRackUnitMbTempStatsRearTemp INTEGER,
+ cucsComputeRackUnitMbTempStatsRearTempAvg INTEGER,
+ cucsComputeRackUnitMbTempStatsRearTempMax INTEGER,
+ cucsComputeRackUnitMbTempStatsRearTempMin INTEGER,
+ cucsComputeRackUnitMbTempStatsSuspect TruthValue,
+ cucsComputeRackUnitMbTempStatsThresholded CucsComputeRackUnitMbTempStatsThresholded,
+ cucsComputeRackUnitMbTempStatsTimeCollected DateAndTime,
+ cucsComputeRackUnitMbTempStatsUpdate Gauge32
+}
+
+cucsComputeRackUnitMbTempStatsInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputeRackUnitMbTempStatsEntry 1 }
+
+cucsComputeRackUnitMbTempStatsDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitMbTempStats:dn managed object property"
+ ::= { cucsComputeRackUnitMbTempStatsEntry 2 }
+
+cucsComputeRackUnitMbTempStatsRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitMbTempStats:rn managed object property"
+ ::= { cucsComputeRackUnitMbTempStatsEntry 3 }
+
+cucsComputeRackUnitMbTempStatsAmbientTemp OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitMbTempStats:ambientTemp
+ managed object property"
+ ::= { cucsComputeRackUnitMbTempStatsEntry 4 }
+
+cucsComputeRackUnitMbTempStatsAmbientTempAvg OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitMbTempStats:ambientTempAvg
+ managed object property"
+ ::= { cucsComputeRackUnitMbTempStatsEntry 5 }
+
+cucsComputeRackUnitMbTempStatsAmbientTempMax OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitMbTempStats:ambientTempMax
+ managed object property"
+ ::= { cucsComputeRackUnitMbTempStatsEntry 6 }
+
+cucsComputeRackUnitMbTempStatsAmbientTempMin OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitMbTempStats:ambientTempMin
+ managed object property"
+ ::= { cucsComputeRackUnitMbTempStatsEntry 7 }
+
+cucsComputeRackUnitMbTempStatsFrontTemp OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitMbTempStats:frontTemp
+ managed object property"
+ ::= { cucsComputeRackUnitMbTempStatsEntry 8 }
+
+cucsComputeRackUnitMbTempStatsFrontTempAvg OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitMbTempStats:frontTempAvg
+ managed object property"
+ ::= { cucsComputeRackUnitMbTempStatsEntry 9 }
+
+cucsComputeRackUnitMbTempStatsFrontTempMax OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitMbTempStats:frontTempMax
+ managed object property"
+ ::= { cucsComputeRackUnitMbTempStatsEntry 10 }
+
+cucsComputeRackUnitMbTempStatsFrontTempMin OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitMbTempStats:frontTempMin
+ managed object property"
+ ::= { cucsComputeRackUnitMbTempStatsEntry 11 }
+
+cucsComputeRackUnitMbTempStatsIntervals OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitMbTempStats:intervals
+ managed object property"
+ ::= { cucsComputeRackUnitMbTempStatsEntry 12 }
+
+cucsComputeRackUnitMbTempStatsIoh1Temp OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitMbTempStats:ioh1Temp
+ managed object property"
+ ::= { cucsComputeRackUnitMbTempStatsEntry 13 }
+
+cucsComputeRackUnitMbTempStatsIoh1TempAvg OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitMbTempStats:ioh1TempAvg
+ managed object property"
+ ::= { cucsComputeRackUnitMbTempStatsEntry 14 }
+
+cucsComputeRackUnitMbTempStatsIoh1TempMax OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitMbTempStats:ioh1TempMax
+ managed object property"
+ ::= { cucsComputeRackUnitMbTempStatsEntry 15 }
+
+cucsComputeRackUnitMbTempStatsIoh1TempMin OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitMbTempStats:ioh1TempMin
+ managed object property"
+ ::= { cucsComputeRackUnitMbTempStatsEntry 16 }
+
+cucsComputeRackUnitMbTempStatsIoh2Temp OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitMbTempStats:ioh2Temp
+ managed object property"
+ ::= { cucsComputeRackUnitMbTempStatsEntry 17 }
+
+cucsComputeRackUnitMbTempStatsIoh2TempAvg OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitMbTempStats:ioh2TempAvg
+ managed object property"
+ ::= { cucsComputeRackUnitMbTempStatsEntry 18 }
+
+cucsComputeRackUnitMbTempStatsIoh2TempMax OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitMbTempStats:ioh2TempMax
+ managed object property"
+ ::= { cucsComputeRackUnitMbTempStatsEntry 19 }
+
+cucsComputeRackUnitMbTempStatsIoh2TempMin OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitMbTempStats:ioh2TempMin
+ managed object property"
+ ::= { cucsComputeRackUnitMbTempStatsEntry 20 }
+
+cucsComputeRackUnitMbTempStatsRearTemp OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitMbTempStats:rearTemp
+ managed object property"
+ ::= { cucsComputeRackUnitMbTempStatsEntry 21 }
+
+cucsComputeRackUnitMbTempStatsRearTempAvg OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitMbTempStats:rearTempAvg
+ managed object property"
+ ::= { cucsComputeRackUnitMbTempStatsEntry 22 }
+
+cucsComputeRackUnitMbTempStatsRearTempMax OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitMbTempStats:rearTempMax
+ managed object property"
+ ::= { cucsComputeRackUnitMbTempStatsEntry 23 }
+
+cucsComputeRackUnitMbTempStatsRearTempMin OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitMbTempStats:rearTempMin
+ managed object property"
+ ::= { cucsComputeRackUnitMbTempStatsEntry 24 }
+
+cucsComputeRackUnitMbTempStatsSuspect OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitMbTempStats:suspect
+ managed object property"
+ ::= { cucsComputeRackUnitMbTempStatsEntry 25 }
+
+cucsComputeRackUnitMbTempStatsThresholded OBJECT-TYPE
+ SYNTAX CucsComputeRackUnitMbTempStatsThresholded
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitMbTempStats:thresholded
+ managed object property"
+ ::= { cucsComputeRackUnitMbTempStatsEntry 26 }
+
+cucsComputeRackUnitMbTempStatsTimeCollected OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitMbTempStats:timeCollected
+ managed object property"
+ ::= { cucsComputeRackUnitMbTempStatsEntry 27 }
+
+cucsComputeRackUnitMbTempStatsUpdate OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitMbTempStats:update managed
+ object property"
+ ::= { cucsComputeRackUnitMbTempStatsEntry 28 }
+
+cucsComputeRackUnitMbTempStatsHistTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputeRackUnitMbTempStatsHistEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitMbTempStatsHist managed object table"
+ ::= { cucsComputeObjects 45 }
+
+cucsComputeRackUnitMbTempStatsHistEntry OBJECT-TYPE
+ SYNTAX CucsComputeRackUnitMbTempStatsHistEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputeRackUnitMbTempStatsHistTable table."
+ INDEX { cucsComputeRackUnitMbTempStatsHistInstanceId }
+ ::= { cucsComputeRackUnitMbTempStatsHistTable 1 }
+
+CucsComputeRackUnitMbTempStatsHistEntry ::= SEQUENCE {
+ cucsComputeRackUnitMbTempStatsHistInstanceId CucsManagedObjectId,
+ cucsComputeRackUnitMbTempStatsHistDn CucsManagedObjectDn,
+ cucsComputeRackUnitMbTempStatsHistRn SnmpAdminString,
+ cucsComputeRackUnitMbTempStatsHistAmbientTemp INTEGER,
+ cucsComputeRackUnitMbTempStatsHistAmbientTempAvg INTEGER,
+ cucsComputeRackUnitMbTempStatsHistAmbientTempMax INTEGER,
+ cucsComputeRackUnitMbTempStatsHistAmbientTempMin INTEGER,
+ cucsComputeRackUnitMbTempStatsHistFrontTemp INTEGER,
+ cucsComputeRackUnitMbTempStatsHistFrontTempAvg INTEGER,
+ cucsComputeRackUnitMbTempStatsHistFrontTempMax INTEGER,
+ cucsComputeRackUnitMbTempStatsHistFrontTempMin INTEGER,
+ cucsComputeRackUnitMbTempStatsHistId Unsigned64,
+ cucsComputeRackUnitMbTempStatsHistIoh1Temp INTEGER,
+ cucsComputeRackUnitMbTempStatsHistIoh1TempAvg INTEGER,
+ cucsComputeRackUnitMbTempStatsHistIoh1TempMax INTEGER,
+ cucsComputeRackUnitMbTempStatsHistIoh1TempMin INTEGER,
+ cucsComputeRackUnitMbTempStatsHistIoh2Temp INTEGER,
+ cucsComputeRackUnitMbTempStatsHistIoh2TempAvg INTEGER,
+ cucsComputeRackUnitMbTempStatsHistIoh2TempMax INTEGER,
+ cucsComputeRackUnitMbTempStatsHistIoh2TempMin INTEGER,
+ cucsComputeRackUnitMbTempStatsHistMostRecent TruthValue,
+ cucsComputeRackUnitMbTempStatsHistRearTemp INTEGER,
+ cucsComputeRackUnitMbTempStatsHistRearTempAvg INTEGER,
+ cucsComputeRackUnitMbTempStatsHistRearTempMax INTEGER,
+ cucsComputeRackUnitMbTempStatsHistRearTempMin INTEGER,
+ cucsComputeRackUnitMbTempStatsHistSuspect TruthValue,
+ cucsComputeRackUnitMbTempStatsHistThresholded CucsComputeRackUnitMbTempStatsHistThresholded,
+ cucsComputeRackUnitMbTempStatsHistTimeCollected DateAndTime
+}
+
+cucsComputeRackUnitMbTempStatsHistInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputeRackUnitMbTempStatsHistEntry 1 }
+
+cucsComputeRackUnitMbTempStatsHistDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitMbTempStatsHist:dn managed
+ object property"
+ ::= { cucsComputeRackUnitMbTempStatsHistEntry 2 }
+
+cucsComputeRackUnitMbTempStatsHistRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitMbTempStatsHist:rn managed
+ object property"
+ ::= { cucsComputeRackUnitMbTempStatsHistEntry 3 }
+
+cucsComputeRackUnitMbTempStatsHistAmbientTemp OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitMbTempStatsHist:ambientTemp
+ managed object property"
+ ::= { cucsComputeRackUnitMbTempStatsHistEntry 4 }
+
+cucsComputeRackUnitMbTempStatsHistAmbientTempAvg OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitMbTempStatsHist:ambientTempAvg
+ managed object property"
+ ::= { cucsComputeRackUnitMbTempStatsHistEntry 5 }
+
+cucsComputeRackUnitMbTempStatsHistAmbientTempMax OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitMbTempStatsHist:ambientTempMax
+ managed object property"
+ ::= { cucsComputeRackUnitMbTempStatsHistEntry 6 }
+
+cucsComputeRackUnitMbTempStatsHistAmbientTempMin OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitMbTempStatsHist:ambientTempMin
+ managed object property"
+ ::= { cucsComputeRackUnitMbTempStatsHistEntry 7 }
+
+cucsComputeRackUnitMbTempStatsHistFrontTemp OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitMbTempStatsHist:frontTemp
+ managed object property"
+ ::= { cucsComputeRackUnitMbTempStatsHistEntry 8 }
+
+cucsComputeRackUnitMbTempStatsHistFrontTempAvg OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitMbTempStatsHist:frontTempAvg
+ managed object property"
+ ::= { cucsComputeRackUnitMbTempStatsHistEntry 9 }
+
+cucsComputeRackUnitMbTempStatsHistFrontTempMax OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitMbTempStatsHist:frontTempMax
+ managed object property"
+ ::= { cucsComputeRackUnitMbTempStatsHistEntry 10 }
+
+cucsComputeRackUnitMbTempStatsHistFrontTempMin OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitMbTempStatsHist:frontTempMin
+ managed object property"
+ ::= { cucsComputeRackUnitMbTempStatsHistEntry 11 }
+
+cucsComputeRackUnitMbTempStatsHistId OBJECT-TYPE
+ SYNTAX Unsigned64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitMbTempStatsHist:id managed
+ object property"
+ ::= { cucsComputeRackUnitMbTempStatsHistEntry 12 }
+
+cucsComputeRackUnitMbTempStatsHistIoh1Temp OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitMbTempStatsHist:ioh1Temp
+ managed object property"
+ ::= { cucsComputeRackUnitMbTempStatsHistEntry 13 }
+
+cucsComputeRackUnitMbTempStatsHistIoh1TempAvg OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitMbTempStatsHist:ioh1TempAvg
+ managed object property"
+ ::= { cucsComputeRackUnitMbTempStatsHistEntry 14 }
+
+cucsComputeRackUnitMbTempStatsHistIoh1TempMax OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitMbTempStatsHist:ioh1TempMax
+ managed object property"
+ ::= { cucsComputeRackUnitMbTempStatsHistEntry 15 }
+
+cucsComputeRackUnitMbTempStatsHistIoh1TempMin OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitMbTempStatsHist:ioh1TempMin
+ managed object property"
+ ::= { cucsComputeRackUnitMbTempStatsHistEntry 16 }
+
+cucsComputeRackUnitMbTempStatsHistIoh2Temp OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitMbTempStatsHist:ioh2Temp
+ managed object property"
+ ::= { cucsComputeRackUnitMbTempStatsHistEntry 17 }
+
+cucsComputeRackUnitMbTempStatsHistIoh2TempAvg OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitMbTempStatsHist:ioh2TempAvg
+ managed object property"
+ ::= { cucsComputeRackUnitMbTempStatsHistEntry 18 }
+
+cucsComputeRackUnitMbTempStatsHistIoh2TempMax OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitMbTempStatsHist:ioh2TempMax
+ managed object property"
+ ::= { cucsComputeRackUnitMbTempStatsHistEntry 19 }
+
+cucsComputeRackUnitMbTempStatsHistIoh2TempMin OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitMbTempStatsHist:ioh2TempMin
+ managed object property"
+ ::= { cucsComputeRackUnitMbTempStatsHistEntry 20 }
+
+cucsComputeRackUnitMbTempStatsHistMostRecent OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitMbTempStatsHist:mostRecent
+ managed object property"
+ ::= { cucsComputeRackUnitMbTempStatsHistEntry 21 }
+
+cucsComputeRackUnitMbTempStatsHistRearTemp OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitMbTempStatsHist:rearTemp
+ managed object property"
+ ::= { cucsComputeRackUnitMbTempStatsHistEntry 22 }
+
+cucsComputeRackUnitMbTempStatsHistRearTempAvg OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitMbTempStatsHist:rearTempAvg
+ managed object property"
+ ::= { cucsComputeRackUnitMbTempStatsHistEntry 23 }
+
+cucsComputeRackUnitMbTempStatsHistRearTempMax OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitMbTempStatsHist:rearTempMax
+ managed object property"
+ ::= { cucsComputeRackUnitMbTempStatsHistEntry 24 }
+
+cucsComputeRackUnitMbTempStatsHistRearTempMin OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitMbTempStatsHist:rearTempMin
+ managed object property"
+ ::= { cucsComputeRackUnitMbTempStatsHistEntry 25 }
+
+cucsComputeRackUnitMbTempStatsHistSuspect OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitMbTempStatsHist:suspect
+ managed object property"
+ ::= { cucsComputeRackUnitMbTempStatsHistEntry 26 }
+
+cucsComputeRackUnitMbTempStatsHistThresholded OBJECT-TYPE
+ SYNTAX CucsComputeRackUnitMbTempStatsHistThresholded
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitMbTempStatsHist:thresholded
+ managed object property"
+ ::= { cucsComputeRackUnitMbTempStatsHistEntry 27 }
+
+cucsComputeRackUnitMbTempStatsHistTimeCollected OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RackUnitMbTempStatsHist:timeCollected
+ managed object property"
+ ::= { cucsComputeRackUnitMbTempStatsHistEntry 28 }
+
+cucsComputeRtcBatteryTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputeRtcBatteryEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RtcBattery managed object table"
+ ::= { cucsComputeObjects 37 }
+
+cucsComputeRtcBatteryEntry OBJECT-TYPE
+ SYNTAX CucsComputeRtcBatteryEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputeRtcBatteryTable table."
+ INDEX { cucsComputeRtcBatteryInstanceId }
+ ::= { cucsComputeRtcBatteryTable 1 }
+
+CucsComputeRtcBatteryEntry ::= SEQUENCE {
+ cucsComputeRtcBatteryInstanceId CucsManagedObjectId,
+ cucsComputeRtcBatteryDn CucsManagedObjectDn,
+ cucsComputeRtcBatteryRn SnmpAdminString,
+ cucsComputeRtcBatteryId Gauge32,
+ cucsComputeRtcBatteryModel SnmpAdminString,
+ cucsComputeRtcBatteryOperState CucsEquipmentOperability,
+ cucsComputeRtcBatteryOperability CucsEquipmentOperability,
+ cucsComputeRtcBatteryPerf CucsEquipmentSensorThresholdStatus,
+ cucsComputeRtcBatteryPower CucsEquipmentPowerState,
+ cucsComputeRtcBatteryPresence CucsEquipmentPresence,
+ cucsComputeRtcBatteryRevision SnmpAdminString,
+ cucsComputeRtcBatterySerial SnmpAdminString,
+ cucsComputeRtcBatteryThermal CucsEquipmentSensorThresholdStatus,
+ cucsComputeRtcBatteryVendor SnmpAdminString,
+ cucsComputeRtcBatteryVoltage CucsEquipmentSensorThresholdStatus,
+ cucsComputeRtcBatteryOperQualifierReason SnmpAdminString,
+ cucsComputeRtcBatteryLocationDn SnmpAdminString
+}
+
+cucsComputeRtcBatteryInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputeRtcBatteryEntry 1 }
+
+cucsComputeRtcBatteryDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RtcBattery:dn managed object property"
+ ::= { cucsComputeRtcBatteryEntry 2 }
+
+cucsComputeRtcBatteryRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RtcBattery:rn managed object property"
+ ::= { cucsComputeRtcBatteryEntry 3 }
+
+cucsComputeRtcBatteryId OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RtcBattery:id managed object property"
+ ::= { cucsComputeRtcBatteryEntry 4 }
+
+cucsComputeRtcBatteryModel OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RtcBattery:model managed object property"
+ ::= { cucsComputeRtcBatteryEntry 5 }
+
+cucsComputeRtcBatteryOperState OBJECT-TYPE
+ SYNTAX CucsEquipmentOperability
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RtcBattery:operState managed object property"
+ ::= { cucsComputeRtcBatteryEntry 6 }
+
+cucsComputeRtcBatteryOperability OBJECT-TYPE
+ SYNTAX CucsEquipmentOperability
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RtcBattery:operability managed object property"
+ ::= { cucsComputeRtcBatteryEntry 7 }
+
+cucsComputeRtcBatteryPerf OBJECT-TYPE
+ SYNTAX CucsEquipmentSensorThresholdStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RtcBattery:perf managed object property"
+ ::= { cucsComputeRtcBatteryEntry 8 }
+
+cucsComputeRtcBatteryPower OBJECT-TYPE
+ SYNTAX CucsEquipmentPowerState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RtcBattery:power managed object property"
+ ::= { cucsComputeRtcBatteryEntry 9 }
+
+cucsComputeRtcBatteryPresence OBJECT-TYPE
+ SYNTAX CucsEquipmentPresence
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RtcBattery:presence managed object property"
+ ::= { cucsComputeRtcBatteryEntry 10 }
+
+cucsComputeRtcBatteryRevision OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RtcBattery:revision managed object property"
+ ::= { cucsComputeRtcBatteryEntry 11 }
+
+cucsComputeRtcBatterySerial OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RtcBattery:serial managed object property"
+ ::= { cucsComputeRtcBatteryEntry 12 }
+
+cucsComputeRtcBatteryThermal OBJECT-TYPE
+ SYNTAX CucsEquipmentSensorThresholdStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RtcBattery:thermal managed object property"
+ ::= { cucsComputeRtcBatteryEntry 13 }
+
+cucsComputeRtcBatteryVendor OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RtcBattery:vendor managed object property"
+ ::= { cucsComputeRtcBatteryEntry 14 }
+
+cucsComputeRtcBatteryVoltage OBJECT-TYPE
+ SYNTAX CucsEquipmentSensorThresholdStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RtcBattery:voltage managed object property"
+ ::= { cucsComputeRtcBatteryEntry 15 }
+
+cucsComputeRtcBatteryOperQualifierReason OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RtcBattery:operQualifierReason
+ managed object property"
+ ::= { cucsComputeRtcBatteryEntry 16 }
+
+cucsComputeRtcBatteryLocationDn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:RtcBattery:locationDn managed object property"
+ ::= { cucsComputeRtcBatteryEntry 17 }
+
+cucsComputeScrubPolicyTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputeScrubPolicyEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ScrubPolicy managed object table"
+ ::= { cucsComputeObjects 38 }
+
+cucsComputeScrubPolicyEntry OBJECT-TYPE
+ SYNTAX CucsComputeScrubPolicyEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputeScrubPolicyTable table."
+ INDEX { cucsComputeScrubPolicyInstanceId }
+ ::= { cucsComputeScrubPolicyTable 1 }
+
+CucsComputeScrubPolicyEntry ::= SEQUENCE {
+ cucsComputeScrubPolicyInstanceId CucsManagedObjectId,
+ cucsComputeScrubPolicyDn CucsManagedObjectDn,
+ cucsComputeScrubPolicyRn SnmpAdminString,
+ cucsComputeScrubPolicyBiosSettingsScrub CucsComputeScrubAction,
+ cucsComputeScrubPolicyDescr SnmpAdminString,
+ cucsComputeScrubPolicyDiskScrub CucsComputeScrubAction,
+ cucsComputeScrubPolicyIntId SnmpAdminString,
+ cucsComputeScrubPolicyName SnmpAdminString,
+ cucsComputeScrubPolicyPolicyLevel Gauge32,
+ cucsComputeScrubPolicyPolicyOwner CucsPolicyPolicyOwner,
+ cucsComputeScrubPolicyFlexFlashScrub CucsComputeScrubAction
+}
+
+cucsComputeScrubPolicyInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputeScrubPolicyEntry 1 }
+
+cucsComputeScrubPolicyDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ScrubPolicy:dn managed object property"
+ ::= { cucsComputeScrubPolicyEntry 2 }
+
+cucsComputeScrubPolicyRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ScrubPolicy:rn managed object property"
+ ::= { cucsComputeScrubPolicyEntry 3 }
+
+cucsComputeScrubPolicyBiosSettingsScrub OBJECT-TYPE
+ SYNTAX CucsComputeScrubAction
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ScrubPolicy:biosSettingsScrub
+ managed object property"
+ ::= { cucsComputeScrubPolicyEntry 4 }
+
+cucsComputeScrubPolicyDescr OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ScrubPolicy:descr managed object property"
+ ::= { cucsComputeScrubPolicyEntry 5 }
+
+cucsComputeScrubPolicyDiskScrub OBJECT-TYPE
+ SYNTAX CucsComputeScrubAction
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ScrubPolicy:diskScrub managed object property"
+ ::= { cucsComputeScrubPolicyEntry 6 }
+
+cucsComputeScrubPolicyIntId OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ScrubPolicy:intId managed object property"
+ ::= { cucsComputeScrubPolicyEntry 7 }
+
+cucsComputeScrubPolicyName OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ScrubPolicy:name managed object property"
+ ::= { cucsComputeScrubPolicyEntry 8 }
+
+cucsComputeScrubPolicyPolicyLevel OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ScrubPolicy:policyLevel managed
+ object property"
+ ::= { cucsComputeScrubPolicyEntry 9 }
+
+cucsComputeScrubPolicyPolicyOwner OBJECT-TYPE
+ SYNTAX CucsPolicyPolicyOwner
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ScrubPolicy:policyOwner managed
+ object property"
+ ::= { cucsComputeScrubPolicyEntry 10 }
+
+cucsComputeScrubPolicyFlexFlashScrub OBJECT-TYPE
+ SYNTAX CucsComputeScrubAction
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ScrubPolicy:flexFlashScrub managed
+ object property"
+ ::= { cucsComputeScrubPolicyEntry 11 }
+
+cucsComputeServerDiscPolicyTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputeServerDiscPolicyEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerDiscPolicy managed object table"
+ ::= { cucsComputeObjects 39 }
+
+cucsComputeServerDiscPolicyEntry OBJECT-TYPE
+ SYNTAX CucsComputeServerDiscPolicyEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputeServerDiscPolicyTable table."
+ INDEX { cucsComputeServerDiscPolicyInstanceId }
+ ::= { cucsComputeServerDiscPolicyTable 1 }
+
+CucsComputeServerDiscPolicyEntry ::= SEQUENCE {
+ cucsComputeServerDiscPolicyInstanceId CucsManagedObjectId,
+ cucsComputeServerDiscPolicyDn CucsManagedObjectDn,
+ cucsComputeServerDiscPolicyRn SnmpAdminString,
+ cucsComputeServerDiscPolicyAction SnmpAdminString,
+ cucsComputeServerDiscPolicyDescr SnmpAdminString,
+ cucsComputeServerDiscPolicyIntId SnmpAdminString,
+ cucsComputeServerDiscPolicyName SnmpAdminString,
+ cucsComputeServerDiscPolicyQualifier SnmpAdminString,
+ cucsComputeServerDiscPolicyScrubPolicyName SnmpAdminString,
+ cucsComputeServerDiscPolicyFsmDescr SnmpAdminString,
+ cucsComputeServerDiscPolicyFsmPrev SnmpAdminString,
+ cucsComputeServerDiscPolicyFsmProgr Gauge32,
+ cucsComputeServerDiscPolicyFsmRmtInvErrCode Gauge32,
+ cucsComputeServerDiscPolicyFsmRmtInvErrDescr SnmpAdminString,
+ cucsComputeServerDiscPolicyFsmRmtInvRslt CucsConditionRemoteInvRslt,
+ cucsComputeServerDiscPolicyFsmStageDescr SnmpAdminString,
+ cucsComputeServerDiscPolicyFsmStamp DateAndTime,
+ cucsComputeServerDiscPolicyFsmStatus SnmpAdminString,
+ cucsComputeServerDiscPolicyFsmTry Gauge32,
+ cucsComputeServerDiscPolicyPolicyLevel Gauge32,
+ cucsComputeServerDiscPolicyPolicyOwner CucsPolicyPolicyOwner
+}
+
+cucsComputeServerDiscPolicyInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputeServerDiscPolicyEntry 1 }
+
+cucsComputeServerDiscPolicyDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerDiscPolicy:dn managed object property"
+ ::= { cucsComputeServerDiscPolicyEntry 2 }
+
+cucsComputeServerDiscPolicyRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerDiscPolicy:rn managed object property"
+ ::= { cucsComputeServerDiscPolicyEntry 3 }
+
+cucsComputeServerDiscPolicyAction OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerDiscPolicy:action managed
+ object property"
+ ::= { cucsComputeServerDiscPolicyEntry 4 }
+
+cucsComputeServerDiscPolicyDescr OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerDiscPolicy:descr managed object property"
+ ::= { cucsComputeServerDiscPolicyEntry 5 }
+
+cucsComputeServerDiscPolicyIntId OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerDiscPolicy:intId managed object property"
+ ::= { cucsComputeServerDiscPolicyEntry 6 }
+
+cucsComputeServerDiscPolicyName OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerDiscPolicy:name managed object property"
+ ::= { cucsComputeServerDiscPolicyEntry 7 }
+
+cucsComputeServerDiscPolicyQualifier OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerDiscPolicy:qualifier managed
+ object property"
+ ::= { cucsComputeServerDiscPolicyEntry 8 }
+
+cucsComputeServerDiscPolicyScrubPolicyName OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerDiscPolicy:scrubPolicyName
+ managed object property"
+ ::= { cucsComputeServerDiscPolicyEntry 9 }
+
+cucsComputeServerDiscPolicyFsmDescr OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerDiscPolicy:fsmDescr managed
+ object property"
+ ::= { cucsComputeServerDiscPolicyEntry 10 }
+
+cucsComputeServerDiscPolicyFsmPrev OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerDiscPolicy:fsmPrev managed
+ object property"
+ ::= { cucsComputeServerDiscPolicyEntry 11 }
+
+cucsComputeServerDiscPolicyFsmProgr OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerDiscPolicy:fsmProgr managed
+ object property"
+ ::= { cucsComputeServerDiscPolicyEntry 12 }
+
+cucsComputeServerDiscPolicyFsmRmtInvErrCode OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerDiscPolicy:fsmRmtInvErrCode
+ managed object property"
+ ::= { cucsComputeServerDiscPolicyEntry 13 }
+
+cucsComputeServerDiscPolicyFsmRmtInvErrDescr OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerDiscPolicy:fsmRmtInvErrDescr
+ managed object property"
+ ::= { cucsComputeServerDiscPolicyEntry 14 }
+
+cucsComputeServerDiscPolicyFsmRmtInvRslt OBJECT-TYPE
+ SYNTAX CucsConditionRemoteInvRslt
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerDiscPolicy:fsmRmtInvRslt
+ managed object property"
+ ::= { cucsComputeServerDiscPolicyEntry 15 }
+
+cucsComputeServerDiscPolicyFsmStageDescr OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerDiscPolicy:fsmStageDescr
+ managed object property"
+ ::= { cucsComputeServerDiscPolicyEntry 16 }
+
+cucsComputeServerDiscPolicyFsmStamp OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerDiscPolicy:fsmStamp managed
+ object property"
+ ::= { cucsComputeServerDiscPolicyEntry 17 }
+
+cucsComputeServerDiscPolicyFsmStatus OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerDiscPolicy:fsmStatus managed
+ object property"
+ ::= { cucsComputeServerDiscPolicyEntry 18 }
+
+cucsComputeServerDiscPolicyFsmTry OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerDiscPolicy:fsmTry managed
+ object property"
+ ::= { cucsComputeServerDiscPolicyEntry 19 }
+
+cucsComputeServerDiscPolicyPolicyLevel OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerDiscPolicy:policyLevel
+ managed object property"
+ ::= { cucsComputeServerDiscPolicyEntry 20 }
+
+cucsComputeServerDiscPolicyPolicyOwner OBJECT-TYPE
+ SYNTAX CucsPolicyPolicyOwner
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerDiscPolicy:policyOwner
+ managed object property"
+ ::= { cucsComputeServerDiscPolicyEntry 21 }
+
+cucsComputeServerDiscPolicyFsmTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputeServerDiscPolicyFsmEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerDiscPolicyFsm managed object table"
+ ::= { cucsComputeObjects 54 }
+
+cucsComputeServerDiscPolicyFsmEntry OBJECT-TYPE
+ SYNTAX CucsComputeServerDiscPolicyFsmEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputeServerDiscPolicyFsmTable table."
+ INDEX { cucsComputeServerDiscPolicyFsmInstanceId }
+ ::= { cucsComputeServerDiscPolicyFsmTable 1 }
+
+CucsComputeServerDiscPolicyFsmEntry ::= SEQUENCE {
+ cucsComputeServerDiscPolicyFsmInstanceId CucsManagedObjectId,
+ cucsComputeServerDiscPolicyFsmDn CucsManagedObjectDn,
+ cucsComputeServerDiscPolicyFsmRn SnmpAdminString,
+ cucsComputeServerDiscPolicyFsmCompletionTime DateAndTime,
+ cucsComputeServerDiscPolicyFsmCurrentFsm CucsComputeServerDiscPolicyFsmCurrentFsm,
+ cucsComputeServerDiscPolicyFsmDescrData SnmpAdminString,
+ cucsComputeServerDiscPolicyFsmFsmStatus CucsFsmFsmStageStatus,
+ cucsComputeServerDiscPolicyFsmProgress Gauge32,
+ cucsComputeServerDiscPolicyFsmRmtErrCode Gauge32,
+ cucsComputeServerDiscPolicyFsmRmtErrDescr SnmpAdminString,
+ cucsComputeServerDiscPolicyFsmRmtRslt CucsConditionRemoteInvRslt
+}
+
+cucsComputeServerDiscPolicyFsmInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputeServerDiscPolicyFsmEntry 1 }
+
+cucsComputeServerDiscPolicyFsmDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerDiscPolicyFsm:dn managed object property"
+ ::= { cucsComputeServerDiscPolicyFsmEntry 2 }
+
+cucsComputeServerDiscPolicyFsmRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerDiscPolicyFsm:rn managed object property"
+ ::= { cucsComputeServerDiscPolicyFsmEntry 3 }
+
+cucsComputeServerDiscPolicyFsmCompletionTime OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerDiscPolicyFsm:completionTime
+ managed object property"
+ ::= { cucsComputeServerDiscPolicyFsmEntry 4 }
+
+cucsComputeServerDiscPolicyFsmCurrentFsm OBJECT-TYPE
+ SYNTAX CucsComputeServerDiscPolicyFsmCurrentFsm
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerDiscPolicyFsm:currentFsm
+ managed object property"
+ ::= { cucsComputeServerDiscPolicyFsmEntry 5 }
+
+cucsComputeServerDiscPolicyFsmDescrData OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerDiscPolicyFsm:descr managed
+ object property"
+ ::= { cucsComputeServerDiscPolicyFsmEntry 6 }
+
+cucsComputeServerDiscPolicyFsmFsmStatus OBJECT-TYPE
+ SYNTAX CucsFsmFsmStageStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerDiscPolicyFsm:fsmStatus
+ managed object property"
+ ::= { cucsComputeServerDiscPolicyFsmEntry 7 }
+
+cucsComputeServerDiscPolicyFsmProgress OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerDiscPolicyFsm:progress
+ managed object property"
+ ::= { cucsComputeServerDiscPolicyFsmEntry 8 }
+
+cucsComputeServerDiscPolicyFsmRmtErrCode OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerDiscPolicyFsm:rmtErrCode
+ managed object property"
+ ::= { cucsComputeServerDiscPolicyFsmEntry 9 }
+
+cucsComputeServerDiscPolicyFsmRmtErrDescr OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerDiscPolicyFsm:rmtErrDescr
+ managed object property"
+ ::= { cucsComputeServerDiscPolicyFsmEntry 10 }
+
+cucsComputeServerDiscPolicyFsmRmtRslt OBJECT-TYPE
+ SYNTAX CucsConditionRemoteInvRslt
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerDiscPolicyFsm:rmtRslt
+ managed object property"
+ ::= { cucsComputeServerDiscPolicyFsmEntry 11 }
+
+cucsComputeServerDiscPolicyFsmStageTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputeServerDiscPolicyFsmStageEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerDiscPolicyFsmStage managed object table"
+ ::= { cucsComputeObjects 55 }
+
+cucsComputeServerDiscPolicyFsmStageEntry OBJECT-TYPE
+ SYNTAX CucsComputeServerDiscPolicyFsmStageEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputeServerDiscPolicyFsmStageTable table."
+ INDEX { cucsComputeServerDiscPolicyFsmStageInstanceId }
+ ::= { cucsComputeServerDiscPolicyFsmStageTable 1 }
+
+CucsComputeServerDiscPolicyFsmStageEntry ::= SEQUENCE {
+ cucsComputeServerDiscPolicyFsmStageInstanceId CucsManagedObjectId,
+ cucsComputeServerDiscPolicyFsmStageDn CucsManagedObjectDn,
+ cucsComputeServerDiscPolicyFsmStageRn SnmpAdminString,
+ cucsComputeServerDiscPolicyFsmStageDescrData SnmpAdminString,
+ cucsComputeServerDiscPolicyFsmStageLastUpdateTime DateAndTime,
+ cucsComputeServerDiscPolicyFsmStageName CucsComputeServerDiscPolicyFsmStageName,
+ cucsComputeServerDiscPolicyFsmStageOrder Gauge32,
+ cucsComputeServerDiscPolicyFsmStageRetry Gauge32,
+ cucsComputeServerDiscPolicyFsmStageStageStatus CucsFsmFsmStageStatus
+}
+
+cucsComputeServerDiscPolicyFsmStageInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputeServerDiscPolicyFsmStageEntry 1 }
+
+cucsComputeServerDiscPolicyFsmStageDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerDiscPolicyFsmStage:dn
+ managed object property"
+ ::= { cucsComputeServerDiscPolicyFsmStageEntry 2 }
+
+cucsComputeServerDiscPolicyFsmStageRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerDiscPolicyFsmStage:rn
+ managed object property"
+ ::= { cucsComputeServerDiscPolicyFsmStageEntry 3 }
+
+cucsComputeServerDiscPolicyFsmStageDescrData OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerDiscPolicyFsmStage:descr
+ managed object property"
+ ::= { cucsComputeServerDiscPolicyFsmStageEntry 4 }
+
+cucsComputeServerDiscPolicyFsmStageLastUpdateTime OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerDiscPolicyFsmStage:lastUpdateTime
+ managed object property"
+ ::= { cucsComputeServerDiscPolicyFsmStageEntry 5 }
+
+cucsComputeServerDiscPolicyFsmStageName OBJECT-TYPE
+ SYNTAX CucsComputeServerDiscPolicyFsmStageName
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerDiscPolicyFsmStage:name
+ managed object property"
+ ::= { cucsComputeServerDiscPolicyFsmStageEntry 6 }
+
+cucsComputeServerDiscPolicyFsmStageOrder OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerDiscPolicyFsmStage:order
+ managed object property"
+ ::= { cucsComputeServerDiscPolicyFsmStageEntry 7 }
+
+cucsComputeServerDiscPolicyFsmStageRetry OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerDiscPolicyFsmStage:retry
+ managed object property"
+ ::= { cucsComputeServerDiscPolicyFsmStageEntry 8 }
+
+cucsComputeServerDiscPolicyFsmStageStageStatus OBJECT-TYPE
+ SYNTAX CucsFsmFsmStageStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerDiscPolicyFsmStage:stageStatus
+ managed object property"
+ ::= { cucsComputeServerDiscPolicyFsmStageEntry 9 }
+
+cucsComputeServerDiscPolicyFsmTaskTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputeServerDiscPolicyFsmTaskEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerDiscPolicyFsmTask managed object table"
+ ::= { cucsComputeObjects 56 }
+
+cucsComputeServerDiscPolicyFsmTaskEntry OBJECT-TYPE
+ SYNTAX CucsComputeServerDiscPolicyFsmTaskEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputeServerDiscPolicyFsmTaskTable table."
+ INDEX { cucsComputeServerDiscPolicyFsmTaskInstanceId }
+ ::= { cucsComputeServerDiscPolicyFsmTaskTable 1 }
+
+CucsComputeServerDiscPolicyFsmTaskEntry ::= SEQUENCE {
+ cucsComputeServerDiscPolicyFsmTaskInstanceId CucsManagedObjectId,
+ cucsComputeServerDiscPolicyFsmTaskDn CucsManagedObjectDn,
+ cucsComputeServerDiscPolicyFsmTaskRn SnmpAdminString,
+ cucsComputeServerDiscPolicyFsmTaskCompletion CucsFsmCompletion,
+ cucsComputeServerDiscPolicyFsmTaskFlags CucsFsmFlags,
+ cucsComputeServerDiscPolicyFsmTaskItem CucsComputeServerDiscPolicyFsmTaskItem,
+ cucsComputeServerDiscPolicyFsmTaskSeqId Gauge32
+}
+
+cucsComputeServerDiscPolicyFsmTaskInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputeServerDiscPolicyFsmTaskEntry 1 }
+
+cucsComputeServerDiscPolicyFsmTaskDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerDiscPolicyFsmTask:dn managed
+ object property"
+ ::= { cucsComputeServerDiscPolicyFsmTaskEntry 2 }
+
+cucsComputeServerDiscPolicyFsmTaskRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerDiscPolicyFsmTask:rn managed
+ object property"
+ ::= { cucsComputeServerDiscPolicyFsmTaskEntry 3 }
+
+cucsComputeServerDiscPolicyFsmTaskCompletion OBJECT-TYPE
+ SYNTAX CucsFsmCompletion
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerDiscPolicyFsmTask:completion
+ managed object property"
+ ::= { cucsComputeServerDiscPolicyFsmTaskEntry 4 }
+
+cucsComputeServerDiscPolicyFsmTaskFlags OBJECT-TYPE
+ SYNTAX CucsFsmFlags
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerDiscPolicyFsmTask:flags
+ managed object property"
+ ::= { cucsComputeServerDiscPolicyFsmTaskEntry 5 }
+
+cucsComputeServerDiscPolicyFsmTaskItem OBJECT-TYPE
+ SYNTAX CucsComputeServerDiscPolicyFsmTaskItem
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerDiscPolicyFsmTask:item
+ managed object property"
+ ::= { cucsComputeServerDiscPolicyFsmTaskEntry 6 }
+
+cucsComputeServerDiscPolicyFsmTaskSeqId OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerDiscPolicyFsmTask:seqId
+ managed object property"
+ ::= { cucsComputeServerDiscPolicyFsmTaskEntry 7 }
+
+cucsComputeServerMgmtPolicyTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputeServerMgmtPolicyEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerMgmtPolicy managed object table"
+ ::= { cucsComputeObjects 57 }
+
+cucsComputeServerMgmtPolicyEntry OBJECT-TYPE
+ SYNTAX CucsComputeServerMgmtPolicyEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputeServerMgmtPolicyTable table."
+ INDEX { cucsComputeServerMgmtPolicyInstanceId }
+ ::= { cucsComputeServerMgmtPolicyTable 1 }
+
+CucsComputeServerMgmtPolicyEntry ::= SEQUENCE {
+ cucsComputeServerMgmtPolicyInstanceId CucsManagedObjectId,
+ cucsComputeServerMgmtPolicyDn CucsManagedObjectDn,
+ cucsComputeServerMgmtPolicyRn SnmpAdminString,
+ cucsComputeServerMgmtPolicyAction CucsComputeServerMgmtDiscAction,
+ cucsComputeServerMgmtPolicyDescr SnmpAdminString,
+ cucsComputeServerMgmtPolicyIntId SnmpAdminString,
+ cucsComputeServerMgmtPolicyName SnmpAdminString,
+ cucsComputeServerMgmtPolicyPolicyLevel Gauge32,
+ cucsComputeServerMgmtPolicyPolicyOwner CucsPolicyPolicyOwner,
+ cucsComputeServerMgmtPolicyQualifier SnmpAdminString
+}
+
+cucsComputeServerMgmtPolicyInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputeServerMgmtPolicyEntry 1 }
+
+cucsComputeServerMgmtPolicyDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerMgmtPolicy:dn managed object property"
+ ::= { cucsComputeServerMgmtPolicyEntry 2 }
+
+cucsComputeServerMgmtPolicyRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerMgmtPolicy:rn managed object property"
+ ::= { cucsComputeServerMgmtPolicyEntry 3 }
+
+cucsComputeServerMgmtPolicyAction OBJECT-TYPE
+ SYNTAX CucsComputeServerMgmtDiscAction
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerMgmtPolicy:action managed
+ object property"
+ ::= { cucsComputeServerMgmtPolicyEntry 4 }
+
+cucsComputeServerMgmtPolicyDescr OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerMgmtPolicy:descr managed object property"
+ ::= { cucsComputeServerMgmtPolicyEntry 5 }
+
+cucsComputeServerMgmtPolicyIntId OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerMgmtPolicy:intId managed object property"
+ ::= { cucsComputeServerMgmtPolicyEntry 6 }
+
+cucsComputeServerMgmtPolicyName OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerMgmtPolicy:name managed object property"
+ ::= { cucsComputeServerMgmtPolicyEntry 7 }
+
+cucsComputeServerMgmtPolicyPolicyLevel OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerMgmtPolicy:policyLevel
+ managed object property"
+ ::= { cucsComputeServerMgmtPolicyEntry 8 }
+
+cucsComputeServerMgmtPolicyPolicyOwner OBJECT-TYPE
+ SYNTAX CucsPolicyPolicyOwner
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerMgmtPolicy:policyOwner
+ managed object property"
+ ::= { cucsComputeServerMgmtPolicyEntry 9 }
+
+cucsComputeServerMgmtPolicyQualifier OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerMgmtPolicy:qualifier managed
+ object property"
+ ::= { cucsComputeServerMgmtPolicyEntry 10 }
+
+cucsComputeServerTypeCapTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputeServerTypeCapEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerTypeCap managed object table"
+ ::= { cucsComputeObjects 68 }
+
+cucsComputeServerTypeCapEntry OBJECT-TYPE
+ SYNTAX CucsComputeServerTypeCapEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputeServerTypeCapTable table."
+ INDEX { cucsComputeServerTypeCapInstanceId }
+ ::= { cucsComputeServerTypeCapTable 1 }
+
+CucsComputeServerTypeCapEntry ::= SEQUENCE {
+ cucsComputeServerTypeCapInstanceId CucsManagedObjectId,
+ cucsComputeServerTypeCapDn CucsManagedObjectDn,
+ cucsComputeServerTypeCapRn SnmpAdminString,
+ cucsComputeServerTypeCapType CucsComputeServerTypeCapType
+}
+
+cucsComputeServerTypeCapInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputeServerTypeCapEntry 1 }
+
+cucsComputeServerTypeCapDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerTypeCap:dn managed object property"
+ ::= { cucsComputeServerTypeCapEntry 2 }
+
+cucsComputeServerTypeCapRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerTypeCap:rn managed object property"
+ ::= { cucsComputeServerTypeCapEntry 3 }
+
+cucsComputeServerTypeCapType OBJECT-TYPE
+ SYNTAX CucsComputeServerTypeCapType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerTypeCap:type managed object property"
+ ::= { cucsComputeServerTypeCapEntry 4 }
+
+cucsComputeServerUnitTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputeServerUnitEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnit managed object table"
+ ::= { cucsComputeObjects 74 }
+
+cucsComputeServerUnitEntry OBJECT-TYPE
+ SYNTAX CucsComputeServerUnitEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputeServerUnitTable table."
+ INDEX { cucsComputeServerUnitInstanceId }
+ ::= { cucsComputeServerUnitTable 1 }
+
+CucsComputeServerUnitEntry ::= SEQUENCE {
+ cucsComputeServerUnitInstanceId CucsManagedObjectId,
+ cucsComputeServerUnitDn CucsManagedObjectDn,
+ cucsComputeServerUnitRn SnmpAdminString,
+ cucsComputeServerUnitAdminPower CucsComputeAdminPowerState,
+ cucsComputeServerUnitAdminState CucsComputeAdminState,
+ cucsComputeServerUnitAssignedToDn SnmpAdminString,
+ cucsComputeServerUnitAssociation CucsComputeAssociation,
+ cucsComputeServerUnitAvailability CucsComputeAvailability,
+ cucsComputeServerUnitAvailableMemory Gauge32,
+ cucsComputeServerUnitChassisId CucsComputeServerUnitChassisId,
+ cucsComputeServerUnitCheckPoint CucsComputeCheckPoint,
+ cucsComputeServerUnitConnPath CucsEquipmentConnectionStatus,
+ cucsComputeServerUnitConnStatus CucsEquipmentConnectionStatus,
+ cucsComputeServerUnitDescr SnmpAdminString,
+ cucsComputeServerUnitDiscovery CucsComputeDiscovery,
+ cucsComputeServerUnitDiscoveryStatus CucsEquipmentConnectionStatus,
+ cucsComputeServerUnitFltAggr Unsigned64,
+ cucsComputeServerUnitFsmDescr SnmpAdminString,
+ cucsComputeServerUnitFsmFlags SnmpAdminString,
+ cucsComputeServerUnitFsmPrev SnmpAdminString,
+ cucsComputeServerUnitFsmProgr Gauge32,
+ cucsComputeServerUnitFsmRmtInvErrCode Gauge32,
+ cucsComputeServerUnitFsmRmtInvErrDescr SnmpAdminString,
+ cucsComputeServerUnitFsmRmtInvRslt CucsConditionRemoteInvRslt,
+ cucsComputeServerUnitFsmStageDescr SnmpAdminString,
+ cucsComputeServerUnitFsmStamp DateAndTime,
+ cucsComputeServerUnitFsmStatus SnmpAdminString,
+ cucsComputeServerUnitFsmTry Gauge32,
+ cucsComputeServerUnitIntId SnmpAdminString,
+ cucsComputeServerUnitLc CucsComputeAdminTrigger,
+ cucsComputeServerUnitLcTs DateAndTime,
+ cucsComputeServerUnitLocalId SnmpAdminString,
+ cucsComputeServerUnitLowVoltageMemory CucsComputePhysicalLowVoltageMemory,
+ cucsComputeServerUnitManagingInst CucsNetworkSwitchId,
+ cucsComputeServerUnitMemorySpeed Gauge32,
+ cucsComputeServerUnitMfgTime DateAndTime,
+ cucsComputeServerUnitModel SnmpAdminString,
+ cucsComputeServerUnitName SnmpAdminString,
+ cucsComputeServerUnitNumOfAdaptors Gauge32,
+ cucsComputeServerUnitNumOfCores Gauge32,
+ cucsComputeServerUnitNumOfCoresEnabled Gauge32,
+ cucsComputeServerUnitNumOfCpus Gauge32,
+ cucsComputeServerUnitNumOfEthHostIfs Gauge32,
+ cucsComputeServerUnitNumOfFcHostIfs Gauge32,
+ cucsComputeServerUnitNumOfThreads Gauge32,
+ cucsComputeServerUnitOperPower CucsEquipmentPowerState,
+ cucsComputeServerUnitOperQualifier CucsComputeIssues,
+ cucsComputeServerUnitOperState CucsLsOperState,
+ cucsComputeServerUnitOperability CucsEquipmentOperability,
+ cucsComputeServerUnitOriginalUuid SnmpAdminString,
+ cucsComputeServerUnitPartNumber SnmpAdminString,
+ cucsComputeServerUnitPolicyLevel Gauge32,
+ cucsComputeServerUnitPolicyOwner CucsPolicyPolicyOwner,
+ cucsComputeServerUnitPresence CucsEquipmentSlotStatus,
+ cucsComputeServerUnitRevision SnmpAdminString,
+ cucsComputeServerUnitSerial SnmpAdminString,
+ cucsComputeServerUnitServerId SnmpAdminString,
+ cucsComputeServerUnitServerInstanceId CucsComputeServerUnitServerInstanceId,
+ cucsComputeServerUnitSlotId CucsComputeServerUnitSlotId,
+ cucsComputeServerUnitTotalMemory Gauge32,
+ cucsComputeServerUnitUsrLbl SnmpAdminString,
+ cucsComputeServerUnitUuid SnmpAdminString,
+ cucsComputeServerUnitVendor SnmpAdminString,
+ cucsComputeServerUnitVid SnmpAdminString,
+ cucsComputeServerUnitNumOf40GAdaptorsWithOldFw Gauge32,
+ cucsComputeServerUnitNumOf40GAdaptorsWithUnknownFw Gauge32,
+ cucsComputeServerUnitOperPwrTransSrc CucsComputePowerTransitionSrc
+}
+
+cucsComputeServerUnitInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputeServerUnitEntry 1 }
+
+cucsComputeServerUnitDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnit:dn managed object property"
+ ::= { cucsComputeServerUnitEntry 2 }
+
+cucsComputeServerUnitRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnit:rn managed object property"
+ ::= { cucsComputeServerUnitEntry 3 }
+
+cucsComputeServerUnitAdminPower OBJECT-TYPE
+ SYNTAX CucsComputeAdminPowerState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnit:adminPower managed object property"
+ ::= { cucsComputeServerUnitEntry 4 }
+
+cucsComputeServerUnitAdminState OBJECT-TYPE
+ SYNTAX CucsComputeAdminState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnit:adminState managed object property"
+ ::= { cucsComputeServerUnitEntry 5 }
+
+cucsComputeServerUnitAssignedToDn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnit:assignedToDn managed
+ object property"
+ ::= { cucsComputeServerUnitEntry 6 }
+
+cucsComputeServerUnitAssociation OBJECT-TYPE
+ SYNTAX CucsComputeAssociation
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnit:association managed object property"
+ ::= { cucsComputeServerUnitEntry 7 }
+
+cucsComputeServerUnitAvailability OBJECT-TYPE
+ SYNTAX CucsComputeAvailability
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnit:availability managed
+ object property"
+ ::= { cucsComputeServerUnitEntry 8 }
+
+cucsComputeServerUnitAvailableMemory OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnit:availableMemory managed
+ object property"
+ ::= { cucsComputeServerUnitEntry 9 }
+
+cucsComputeServerUnitChassisId OBJECT-TYPE
+ SYNTAX CucsComputeServerUnitChassisId
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnit:chassisId managed object property"
+ ::= { cucsComputeServerUnitEntry 10 }
+
+cucsComputeServerUnitCheckPoint OBJECT-TYPE
+ SYNTAX CucsComputeCheckPoint
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnit:checkPoint managed object property"
+ ::= { cucsComputeServerUnitEntry 11 }
+
+cucsComputeServerUnitConnPath OBJECT-TYPE
+ SYNTAX CucsEquipmentConnectionStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnit:connPath managed object property"
+ ::= { cucsComputeServerUnitEntry 12 }
+
+cucsComputeServerUnitConnStatus OBJECT-TYPE
+ SYNTAX CucsEquipmentConnectionStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnit:connStatus managed object property"
+ ::= { cucsComputeServerUnitEntry 13 }
+
+cucsComputeServerUnitDescr OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnit:descr managed object property"
+ ::= { cucsComputeServerUnitEntry 14 }
+
+cucsComputeServerUnitDiscovery OBJECT-TYPE
+ SYNTAX CucsComputeDiscovery
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnit:discovery managed object property"
+ ::= { cucsComputeServerUnitEntry 15 }
+
+cucsComputeServerUnitDiscoveryStatus OBJECT-TYPE
+ SYNTAX CucsEquipmentConnectionStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnit:discoveryStatus managed
+ object property"
+ ::= { cucsComputeServerUnitEntry 16 }
+
+cucsComputeServerUnitFltAggr OBJECT-TYPE
+ SYNTAX Unsigned64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnit:fltAggr managed object property"
+ ::= { cucsComputeServerUnitEntry 17 }
+
+cucsComputeServerUnitFsmDescr OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnit:fsmDescr managed object property"
+ ::= { cucsComputeServerUnitEntry 18 }
+
+cucsComputeServerUnitFsmFlags OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnit:fsmFlags managed object property"
+ ::= { cucsComputeServerUnitEntry 19 }
+
+cucsComputeServerUnitFsmPrev OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnit:fsmPrev managed object property"
+ ::= { cucsComputeServerUnitEntry 20 }
+
+cucsComputeServerUnitFsmProgr OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnit:fsmProgr managed object property"
+ ::= { cucsComputeServerUnitEntry 21 }
+
+cucsComputeServerUnitFsmRmtInvErrCode OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnit:fsmRmtInvErrCode
+ managed object property"
+ ::= { cucsComputeServerUnitEntry 22 }
+
+cucsComputeServerUnitFsmRmtInvErrDescr OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnit:fsmRmtInvErrDescr
+ managed object property"
+ ::= { cucsComputeServerUnitEntry 23 }
+
+cucsComputeServerUnitFsmRmtInvRslt OBJECT-TYPE
+ SYNTAX CucsConditionRemoteInvRslt
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnit:fsmRmtInvRslt managed
+ object property"
+ ::= { cucsComputeServerUnitEntry 24 }
+
+cucsComputeServerUnitFsmStageDescr OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnit:fsmStageDescr managed
+ object property"
+ ::= { cucsComputeServerUnitEntry 25 }
+
+cucsComputeServerUnitFsmStamp OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnit:fsmStamp managed object property"
+ ::= { cucsComputeServerUnitEntry 26 }
+
+cucsComputeServerUnitFsmStatus OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnit:fsmStatus managed object property"
+ ::= { cucsComputeServerUnitEntry 27 }
+
+cucsComputeServerUnitFsmTry OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnit:fsmTry managed object property"
+ ::= { cucsComputeServerUnitEntry 28 }
+
+cucsComputeServerUnitIntId OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnit:intId managed object property"
+ ::= { cucsComputeServerUnitEntry 29 }
+
+cucsComputeServerUnitLc OBJECT-TYPE
+ SYNTAX CucsComputeAdminTrigger
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnit:lc managed object property"
+ ::= { cucsComputeServerUnitEntry 30 }
+
+cucsComputeServerUnitLcTs OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnit:lcTs managed object property"
+ ::= { cucsComputeServerUnitEntry 31 }
+
+cucsComputeServerUnitLocalId OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnit:localId managed object property"
+ ::= { cucsComputeServerUnitEntry 32 }
+
+cucsComputeServerUnitLowVoltageMemory OBJECT-TYPE
+ SYNTAX CucsComputePhysicalLowVoltageMemory
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnit:lowVoltageMemory
+ managed object property"
+ ::= { cucsComputeServerUnitEntry 33 }
+
+cucsComputeServerUnitManagingInst OBJECT-TYPE
+ SYNTAX CucsNetworkSwitchId
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnit:managingInst managed
+ object property"
+ ::= { cucsComputeServerUnitEntry 34 }
+
+cucsComputeServerUnitMemorySpeed OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnit:memorySpeed managed object property"
+ ::= { cucsComputeServerUnitEntry 35 }
+
+cucsComputeServerUnitMfgTime OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnit:mfgTime managed object property"
+ ::= { cucsComputeServerUnitEntry 36 }
+
+cucsComputeServerUnitModel OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnit:model managed object property"
+ ::= { cucsComputeServerUnitEntry 37 }
+
+cucsComputeServerUnitName OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnit:name managed object property"
+ ::= { cucsComputeServerUnitEntry 38 }
+
+cucsComputeServerUnitNumOfAdaptors OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnit:numOfAdaptors managed
+ object property"
+ ::= { cucsComputeServerUnitEntry 39 }
+
+cucsComputeServerUnitNumOfCores OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnit:numOfCores managed object property"
+ ::= { cucsComputeServerUnitEntry 40 }
+
+cucsComputeServerUnitNumOfCoresEnabled OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnit:numOfCoresEnabled
+ managed object property"
+ ::= { cucsComputeServerUnitEntry 41 }
+
+cucsComputeServerUnitNumOfCpus OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnit:numOfCpus managed object property"
+ ::= { cucsComputeServerUnitEntry 42 }
+
+cucsComputeServerUnitNumOfEthHostIfs OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnit:numOfEthHostIfs managed
+ object property"
+ ::= { cucsComputeServerUnitEntry 43 }
+
+cucsComputeServerUnitNumOfFcHostIfs OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnit:numOfFcHostIfs managed
+ object property"
+ ::= { cucsComputeServerUnitEntry 44 }
+
+cucsComputeServerUnitNumOfThreads OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnit:numOfThreads managed
+ object property"
+ ::= { cucsComputeServerUnitEntry 45 }
+
+cucsComputeServerUnitOperPower OBJECT-TYPE
+ SYNTAX CucsEquipmentPowerState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnit:operPower managed object property"
+ ::= { cucsComputeServerUnitEntry 46 }
+
+cucsComputeServerUnitOperQualifier OBJECT-TYPE
+ SYNTAX CucsComputeIssues
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnit:operQualifier managed
+ object property"
+ ::= { cucsComputeServerUnitEntry 47 }
+
+cucsComputeServerUnitOperState OBJECT-TYPE
+ SYNTAX CucsLsOperState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnit:operState managed object property"
+ ::= { cucsComputeServerUnitEntry 48 }
+
+cucsComputeServerUnitOperability OBJECT-TYPE
+ SYNTAX CucsEquipmentOperability
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnit:operability managed object property"
+ ::= { cucsComputeServerUnitEntry 49 }
+
+cucsComputeServerUnitOriginalUuid OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnit:originalUuid managed
+ object property"
+ ::= { cucsComputeServerUnitEntry 50 }
+
+cucsComputeServerUnitPartNumber OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnit:partNumber managed object property"
+ ::= { cucsComputeServerUnitEntry 51 }
+
+cucsComputeServerUnitPolicyLevel OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnit:policyLevel managed object property"
+ ::= { cucsComputeServerUnitEntry 52 }
+
+cucsComputeServerUnitPolicyOwner OBJECT-TYPE
+ SYNTAX CucsPolicyPolicyOwner
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnit:policyOwner managed object property"
+ ::= { cucsComputeServerUnitEntry 53 }
+
+cucsComputeServerUnitPresence OBJECT-TYPE
+ SYNTAX CucsEquipmentSlotStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnit:presence managed object property"
+ ::= { cucsComputeServerUnitEntry 54 }
+
+cucsComputeServerUnitRevision OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnit:revision managed object property"
+ ::= { cucsComputeServerUnitEntry 55 }
+
+cucsComputeServerUnitSerial OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnit:serial managed object property"
+ ::= { cucsComputeServerUnitEntry 56 }
+
+cucsComputeServerUnitServerId OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnit:serverId managed object property"
+ ::= { cucsComputeServerUnitEntry 57 }
+
+cucsComputeServerUnitServerInstanceId OBJECT-TYPE
+ SYNTAX CucsComputeServerUnitServerInstanceId
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnit:serverInstanceId
+ managed object property"
+ ::= { cucsComputeServerUnitEntry 58 }
+
+cucsComputeServerUnitSlotId OBJECT-TYPE
+ SYNTAX CucsComputeServerUnitSlotId
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnit:slotId managed object property"
+ ::= { cucsComputeServerUnitEntry 59 }
+
+cucsComputeServerUnitTotalMemory OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnit:totalMemory managed object property"
+ ::= { cucsComputeServerUnitEntry 60 }
+
+cucsComputeServerUnitUsrLbl OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnit:usrLbl managed object property"
+ ::= { cucsComputeServerUnitEntry 61 }
+
+cucsComputeServerUnitUuid OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnit:uuid managed object property"
+ ::= { cucsComputeServerUnitEntry 62 }
+
+cucsComputeServerUnitVendor OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnit:vendor managed object property"
+ ::= { cucsComputeServerUnitEntry 63 }
+
+cucsComputeServerUnitVid OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnit:vid managed object property"
+ ::= { cucsComputeServerUnitEntry 64 }
+
+cucsComputeServerUnitNumOf40GAdaptorsWithOldFw OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnit:numOf40GAdaptorsWithOldFw
+ managed object property"
+ ::= { cucsComputeServerUnitEntry 66 }
+
+cucsComputeServerUnitNumOf40GAdaptorsWithUnknownFw OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnit:numOf40GAdaptorsWithUnknownFw
+ managed object property"
+ ::= { cucsComputeServerUnitEntry 67 }
+
+cucsComputeServerUnitOperPwrTransSrc OBJECT-TYPE
+ SYNTAX CucsComputePowerTransitionSrc
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnit:operPwrTransSrc managed
+ object property"
+ ::= { cucsComputeServerUnitEntry 68 }
+
+cucsComputeServerUnitFsmTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputeServerUnitFsmEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnitFsm managed object table"
+ ::= { cucsComputeObjects 75 }
+
+cucsComputeServerUnitFsmEntry OBJECT-TYPE
+ SYNTAX CucsComputeServerUnitFsmEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputeServerUnitFsmTable table."
+ INDEX { cucsComputeServerUnitFsmInstanceId }
+ ::= { cucsComputeServerUnitFsmTable 1 }
+
+CucsComputeServerUnitFsmEntry ::= SEQUENCE {
+ cucsComputeServerUnitFsmInstanceId CucsManagedObjectId,
+ cucsComputeServerUnitFsmDn CucsManagedObjectDn,
+ cucsComputeServerUnitFsmRn SnmpAdminString,
+ cucsComputeServerUnitFsmCompletionTime DateAndTime,
+ cucsComputeServerUnitFsmCurrentFsm CucsComputeServerUnitFsmCurrentFsm,
+ cucsComputeServerUnitFsmDescrData SnmpAdminString,
+ cucsComputeServerUnitFsmFsmStatus CucsFsmFsmStageStatus,
+ cucsComputeServerUnitFsmProgress Gauge32,
+ cucsComputeServerUnitFsmRmtErrCode Gauge32,
+ cucsComputeServerUnitFsmRmtErrDescr SnmpAdminString,
+ cucsComputeServerUnitFsmRmtRslt CucsConditionRemoteInvRslt
+}
+
+cucsComputeServerUnitFsmInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputeServerUnitFsmEntry 1 }
+
+cucsComputeServerUnitFsmDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnitFsm:dn managed object property"
+ ::= { cucsComputeServerUnitFsmEntry 2 }
+
+cucsComputeServerUnitFsmRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnitFsm:rn managed object property"
+ ::= { cucsComputeServerUnitFsmEntry 3 }
+
+cucsComputeServerUnitFsmCompletionTime OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnitFsm:completionTime
+ managed object property"
+ ::= { cucsComputeServerUnitFsmEntry 4 }
+
+cucsComputeServerUnitFsmCurrentFsm OBJECT-TYPE
+ SYNTAX CucsComputeServerUnitFsmCurrentFsm
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnitFsm:currentFsm managed
+ object property"
+ ::= { cucsComputeServerUnitFsmEntry 5 }
+
+cucsComputeServerUnitFsmDescrData OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnitFsm:descr managed object property"
+ ::= { cucsComputeServerUnitFsmEntry 6 }
+
+cucsComputeServerUnitFsmFsmStatus OBJECT-TYPE
+ SYNTAX CucsFsmFsmStageStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnitFsm:fsmStatus managed
+ object property"
+ ::= { cucsComputeServerUnitFsmEntry 7 }
+
+cucsComputeServerUnitFsmProgress OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnitFsm:progress managed object property"
+ ::= { cucsComputeServerUnitFsmEntry 8 }
+
+cucsComputeServerUnitFsmRmtErrCode OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnitFsm:rmtErrCode managed
+ object property"
+ ::= { cucsComputeServerUnitFsmEntry 9 }
+
+cucsComputeServerUnitFsmRmtErrDescr OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnitFsm:rmtErrDescr managed
+ object property"
+ ::= { cucsComputeServerUnitFsmEntry 10 }
+
+cucsComputeServerUnitFsmRmtRslt OBJECT-TYPE
+ SYNTAX CucsConditionRemoteInvRslt
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnitFsm:rmtRslt managed object property"
+ ::= { cucsComputeServerUnitFsmEntry 11 }
+
+cucsComputeServerUnitFsmStageTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputeServerUnitFsmStageEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnitFsmStage managed object table"
+ ::= { cucsComputeObjects 76 }
+
+cucsComputeServerUnitFsmStageEntry OBJECT-TYPE
+ SYNTAX CucsComputeServerUnitFsmStageEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputeServerUnitFsmStageTable table."
+ INDEX { cucsComputeServerUnitFsmStageInstanceId }
+ ::= { cucsComputeServerUnitFsmStageTable 1 }
+
+CucsComputeServerUnitFsmStageEntry ::= SEQUENCE {
+ cucsComputeServerUnitFsmStageInstanceId CucsManagedObjectId,
+ cucsComputeServerUnitFsmStageDn CucsManagedObjectDn,
+ cucsComputeServerUnitFsmStageRn SnmpAdminString,
+ cucsComputeServerUnitFsmStageDescrData SnmpAdminString,
+ cucsComputeServerUnitFsmStageLastUpdateTime DateAndTime,
+ cucsComputeServerUnitFsmStageName CucsComputeServerUnitFsmStageName,
+ cucsComputeServerUnitFsmStageOrder Gauge32,
+ cucsComputeServerUnitFsmStageRetry Gauge32,
+ cucsComputeServerUnitFsmStageStageStatus CucsFsmFsmStageStatus
+}
+
+cucsComputeServerUnitFsmStageInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputeServerUnitFsmStageEntry 1 }
+
+cucsComputeServerUnitFsmStageDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnitFsmStage:dn managed object property"
+ ::= { cucsComputeServerUnitFsmStageEntry 2 }
+
+cucsComputeServerUnitFsmStageRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnitFsmStage:rn managed object property"
+ ::= { cucsComputeServerUnitFsmStageEntry 3 }
+
+cucsComputeServerUnitFsmStageDescrData OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnitFsmStage:descr managed
+ object property"
+ ::= { cucsComputeServerUnitFsmStageEntry 4 }
+
+cucsComputeServerUnitFsmStageLastUpdateTime OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnitFsmStage:lastUpdateTime
+ managed object property"
+ ::= { cucsComputeServerUnitFsmStageEntry 5 }
+
+cucsComputeServerUnitFsmStageName OBJECT-TYPE
+ SYNTAX CucsComputeServerUnitFsmStageName
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnitFsmStage:name managed
+ object property"
+ ::= { cucsComputeServerUnitFsmStageEntry 6 }
+
+cucsComputeServerUnitFsmStageOrder OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnitFsmStage:order managed
+ object property"
+ ::= { cucsComputeServerUnitFsmStageEntry 7 }
+
+cucsComputeServerUnitFsmStageRetry OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnitFsmStage:retry managed
+ object property"
+ ::= { cucsComputeServerUnitFsmStageEntry 8 }
+
+cucsComputeServerUnitFsmStageStageStatus OBJECT-TYPE
+ SYNTAX CucsFsmFsmStageStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnitFsmStage:stageStatus
+ managed object property"
+ ::= { cucsComputeServerUnitFsmStageEntry 9 }
+
+cucsComputeServerUnitFsmTaskTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputeServerUnitFsmTaskEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnitFsmTask managed object table"
+ ::= { cucsComputeObjects 77 }
+
+cucsComputeServerUnitFsmTaskEntry OBJECT-TYPE
+ SYNTAX CucsComputeServerUnitFsmTaskEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputeServerUnitFsmTaskTable table."
+ INDEX { cucsComputeServerUnitFsmTaskInstanceId }
+ ::= { cucsComputeServerUnitFsmTaskTable 1 }
+
+CucsComputeServerUnitFsmTaskEntry ::= SEQUENCE {
+ cucsComputeServerUnitFsmTaskInstanceId CucsManagedObjectId,
+ cucsComputeServerUnitFsmTaskDn CucsManagedObjectDn,
+ cucsComputeServerUnitFsmTaskRn SnmpAdminString,
+ cucsComputeServerUnitFsmTaskCompletion CucsFsmCompletion,
+ cucsComputeServerUnitFsmTaskFlags CucsComputeServerUnitFsmTaskFlags,
+ cucsComputeServerUnitFsmTaskItem CucsComputeServerUnitFsmTaskItem,
+ cucsComputeServerUnitFsmTaskSeqId Gauge32
+}
+
+cucsComputeServerUnitFsmTaskInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputeServerUnitFsmTaskEntry 1 }
+
+cucsComputeServerUnitFsmTaskDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnitFsmTask:dn managed object property"
+ ::= { cucsComputeServerUnitFsmTaskEntry 2 }
+
+cucsComputeServerUnitFsmTaskRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnitFsmTask:rn managed object property"
+ ::= { cucsComputeServerUnitFsmTaskEntry 3 }
+
+cucsComputeServerUnitFsmTaskCompletion OBJECT-TYPE
+ SYNTAX CucsFsmCompletion
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnitFsmTask:completion
+ managed object property"
+ ::= { cucsComputeServerUnitFsmTaskEntry 4 }
+
+cucsComputeServerUnitFsmTaskFlags OBJECT-TYPE
+ SYNTAX CucsComputeServerUnitFsmTaskFlags
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnitFsmTask:flags managed
+ object property"
+ ::= { cucsComputeServerUnitFsmTaskEntry 5 }
+
+cucsComputeServerUnitFsmTaskItem OBJECT-TYPE
+ SYNTAX CucsComputeServerUnitFsmTaskItem
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnitFsmTask:item managed object property"
+ ::= { cucsComputeServerUnitFsmTaskEntry 6 }
+
+cucsComputeServerUnitFsmTaskSeqId OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:ServerUnitFsmTask:seqId managed
+ object property"
+ ::= { cucsComputeServerUnitFsmTaskEntry 7 }
+
+cucsComputeSlotQualTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CucsComputeSlotQualEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:SlotQual managed object table"
+ ::= { cucsComputeObjects 40 }
+
+cucsComputeSlotQualEntry OBJECT-TYPE
+ SYNTAX CucsComputeSlotQualEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for the cucsComputeSlotQualTable table."
+ INDEX { cucsComputeSlotQualInstanceId }
+ ::= { cucsComputeSlotQualTable 1 }
+
+CucsComputeSlotQualEntry ::= SEQUENCE {
+ cucsComputeSlotQualInstanceId CucsManagedObjectId,
+ cucsComputeSlotQualDn CucsManagedObjectDn,
+ cucsComputeSlotQualRn SnmpAdminString,
+ cucsComputeSlotQualMaxId CucsComputeSlotQualMaxId,
+ cucsComputeSlotQualMinId CucsComputeSlotQualMinId
+}
+
+cucsComputeSlotQualInstanceId OBJECT-TYPE
+ SYNTAX CucsManagedObjectId
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Instance identifier of the managed object."
+ ::= { cucsComputeSlotQualEntry 1 }
+
+cucsComputeSlotQualDn OBJECT-TYPE
+ SYNTAX CucsManagedObjectDn
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:SlotQual:dn managed object property"
+ ::= { cucsComputeSlotQualEntry 2 }
+
+cucsComputeSlotQualRn OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:SlotQual:rn managed object property"
+ ::= { cucsComputeSlotQualEntry 3 }
+
+cucsComputeSlotQualMaxId OBJECT-TYPE
+ SYNTAX CucsComputeSlotQualMaxId
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:SlotQual:maxId managed object property"
+ ::= { cucsComputeSlotQualEntry 4 }
+
+cucsComputeSlotQualMinId OBJECT-TYPE
+ SYNTAX CucsComputeSlotQualMinId
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cisco UCS compute:SlotQual:minId managed object property"
+ ::= { cucsComputeSlotQualEntry 5 }
+
+END