diff options
| author | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
|---|---|---|
| committer | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
| commit | 98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch) | |
| tree | 9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/cisco/CISCOSB-Physicaldescription-MIB | |
| download | mibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.tar.gz mibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.zip | |
Diffstat (limited to 'MIBS/cisco/CISCOSB-Physicaldescription-MIB')
| -rw-r--r-- | MIBS/cisco/CISCOSB-Physicaldescription-MIB | 1453 |
1 files changed, 1453 insertions, 0 deletions
diff --git a/MIBS/cisco/CISCOSB-Physicaldescription-MIB b/MIBS/cisco/CISCOSB-Physicaldescription-MIB new file mode 100644 index 0000000..03fff0a --- /dev/null +++ b/MIBS/cisco/CISCOSB-Physicaldescription-MIB @@ -0,0 +1,1453 @@ +CISCOSB-Physicaldescription-MIB DEFINITIONS ::= BEGIN + +-- Version: 7.46 +-- Date: 15-Jan-2007 +-- +-- 30-Jan-2004 Add rlPhdUnitGenParamTable +-- 30-Jan-2004 Add rlPhdUnitEnvParamTable +-- 24-Feb-2004 Add rlPhdStackOrderTopUnit +-- 24-Feb-2004 Add rlPhdStackOrderBottomUnit +-- 24-Feb-2004 Add rlPhdStackOrderPermutation +-- 21-Apr-2005 Add rlPhdPortsTable switch description between: +-- rlPhdPortsModuleNumber && rlPhdPortsStackUnit due to EWS need +-- 27-Apr-2005 Add rlStackLinkChange trap. +-- 16-May-2005 Add rlPhdNumberOfPoeUnits +-- 02-Jun-2005 Add field to rlPhDUnitEnvParamTable: rlPhdUnitEnvParamUpTime +-- 25-Jul-2005 Add rlPhdPhyLedTimeout and rlPhdPhyLedStackUnit +-- 03-Aug-2005 Remove boundary for unit number field, checked by box +-- this is done coz different products use different stack size +-- 05-Sep-2005 Add rlCascadeTable +-- 31-Oct-2005 Add rlCascadeAfterResetTable +-- 14-Nov-2005 Change rlPhdUnitGenParamSerialNum to read-write +-- 16-May-2006 Add field rlCascadeUnitId to rlCascadeEntry +-- 14-Jan-2007 rlPhdModuleType was moved to a separated text file +-- 15-Jan-2007 Devided file appolo.txt to a few files +-- Renamed file appolo.txt to ralan-mib.mib +-- 23-Jul-2012 IdanS: Add rlPhdUnitGenParamRegistrationDone and rlPhdUnitGenParamRegistrationSuppressed to RlPhdUnitGenParamEntry +-- 09-Oct-2012 yahal: Add rlPhdUnitEnvParamMonitorAutoRecoveryEnable & rlPhdUnitEnvParamMonitorTemperatureStatus & rlPhdUnitEnvParamMonitorTemperatureStatus +-- 08-Jan-2015 YoramSu: Add rlPhdUnitEnvParamTempSensorWarningThresholdValue and rlPhdUnitEnvParamTempSensorCriticalThresholdValue to rlPhdUnitEnvParamEntry +-- 25-Aug-2016 YoramSu: Add rlPhdPhyLedTimeRemaining scalar + +IMPORTS + OBJECT-TYPE, MODULE-IDENTITY, TimeTicks, + NOTIFICATION-TYPE FROM SNMPv2-SMI + DisplayString, PhysAddress, RowStatus, TruthValue FROM SNMPv2-TC + JackType FROM MAU-MIB + switch001, rndNotifications FROM CISCOSB-MIB + RlEnvMonState FROM CISCOSB-HWENVIROMENT + EntitySensorStatus, EntitySensorValue FROM ENTITY-SENSOR-MIB + InterfaceIndexOrZero,ifIndex,InterfaceIndex FROM IF-MIB + rndErrorDesc, rndErrorSeverity FROM CISCOSB-DEVICEPARAMS-MIB; + +rlPhysicalDescription MODULE-IDENTITY + LAST-UPDATED "202105190000Z" + ORGANIZATION "Cisco Systems, Inc." + + CONTACT-INFO + "Postal: 170 West Tasman Drive + San Jose , CA 95134-1706 + USA + + + Website: Cisco Small Business Support Community <http://www.cisco.com/go/smallbizsupport>" + + DESCRIPTION + "The private MIB module definition for physical + device configuration." + REVISION "202105190000Z" + DESCRIPTION + "Removed TRAP-TYPE from IMPORTS." + REVISION "200310180000Z" + DESCRIPTION + "Initial version of this MIB." + ::= { switch001 53 } + +CascadePortState ::= INTEGER { + error (0), + init (1), + down (2), + active (3), + standby (4) +} + +CascadePortSpeed ::= INTEGER { + port-speed-unknown (0), + port-speed-100M (1), + port-speed-1G (2), + port-speed-10G (3), + port-speed-5G (6), + port-speed-20G (8), + port-speed-40G (9), + port-speed-100G (13), + port-speed-auto (14) +} + +LedLocatorPattern ::= INTEGER { + pattern-unknown (0), + pattern-blink (1), + pattern-alternating (2), + pattern-system (3) +} + + +rlPhdMibVersion OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "MIB's version, the current version is 3. + 1: original version + 2: a. new tables + rlPhdModuleHotSwapTable + rlPhdStackOrderTable + b. new scalars + rlPhdStackReorder + rlPhdNumberOfUnits + rlPhdMaxNumberOfUnits + 3: a. new field rlPhdModuleRole of rlPhdModuleTable + b. new scalars + rlPhdForceControllerUnit + 4: a. new fields rlPhdModuleConnect1 and rlPhdModuleConnect2 + of rlPhdModuleTable. + 5: a. Prefix rlPhD were replaced by prefix rlPhd + b. fields rlPhdModuleConnect1 and rlPhdModuleConnect2 are + moved from rlPhdModuleTable to rlPhdStackTable. + c. new fiels rlPhdStackSofrwareVer, rlPhdStackProductID and + rlPhdStackMacAddr of rlPhdStackTable. + d. new scalars + rlPhdStackReloadUnit + e. new scalars + rlPhdStackOrderTopUnit + rlPhdStackOrderBottomUnit + rlPhdStackOrderPermutation" + ::= { rlPhysicalDescription 1 } + +rlPhdModuleTable OBJECT-TYPE + SYNTAX SEQUENCE OF RlPhdModuleEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "For each module (board) there is an entry describing it in this + module" + ::= { rlPhysicalDescription 2 } + +rlPhdModuleEntry OBJECT-TYPE + SYNTAX RlPhdModuleEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A entry of this table specifies a module (board)" + INDEX { rlPhdModuleStackUnit, rlPhdModuleIndex} + ::= { rlPhdModuleTable 1 } + +RlPhdModuleEntry ::= SEQUENCE { + rlPhdModuleStackUnit INTEGER, + rlPhdModuleIndex INTEGER, + rlPhdModuleType INTEGER, + rlPhdModuleStartingPort INTEGER, + rlPhdModuleNumberOfPorts INTEGER, + rlPhdModuleRow INTEGER, + rlPhdModuleColumn INTEGER, + rlPhdModuleRole INTEGER +} + +rlPhdModuleStackUnit OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of the stack unit" + ::= { rlPhdModuleEntry 1 } + +rlPhdModuleIndex OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of the module in its stack unit" + ::= { rlPhdModuleEntry 2 } + +rlPhdModuleType OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The index for each module type" + ::= { rlPhdModuleEntry 3 } + +rlPhdModuleStartingPort OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The minimal number of the port residing on this module." + ::= { rlPhdModuleEntry 4 } + +rlPhdModuleNumberOfPorts OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of ports residing on this module." + ::= { rlPhdModuleEntry 5} + +rlPhdModuleRow OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "On which row (the uppermost being numbered 1 and the highest row + number asigned to the lowest row) this module resides within the + chassis of its stack unit." + ::= { rlPhdModuleEntry 6 } + +rlPhdModuleColumn OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "On which column (the leftmost being numbered 1 and the highest column + number asigned to the rightmost column) this module resides within the + chassis of its stack unit." + ::= { rlPhdModuleEntry 7 } + +rlPhdModuleRole OBJECT-TYPE + SYNTAX INTEGER { + standalone(1), + controller(2), + backup(3), + member(4) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The module role in the stack." + DEFVAL { standalone } + ::= { rlPhdModuleEntry 8 } + +rlPhdPortsTable OBJECT-TYPE + SYNTAX SEQUENCE OF RlPhdPortsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Lists the physical or physical-related attributes of ports" + ::= { rlPhysicalDescription 3 } + +rlPhdPortsEntry OBJECT-TYPE + SYNTAX RlPhdPortsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "For each port, a entry describing attributes which are either + physical or are derived from the features of the device hardware" + INDEX { rlPhdPortsIfIndex } + ::= { rlPhdPortsTable 1 } + +RlPhdPortsEntry ::= SEQUENCE { + rlPhdPortsIfIndex INTEGER, + rlPhdPortsIfIndexName DisplayString(SIZE(1..20)), + rlPhdPortsMediaType INTEGER, + rlPhdPortsStackUnit INTEGER, + rlPhdPortsModuleNumber INTEGER, + rlPhdPortsRow INTEGER, + rlPhdPortsColumn INTEGER, + rlPhdConnectorType JackType, + rlPhdPortHaul INTEGER + + } + +rlPhdPortsIfIndex OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The L2 interface number associated with this port." + ::= { rlPhdPortsEntry 1 } + +rlPhdPortsIfIndexName OBJECT-TYPE + SYNTAX DisplayString(SIZE(1..20)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The L2 interface number associated with this port, in string format + based on the overall hardware architecture of the device (i.e., for + monolithic devices just numbers, devices composed of modules (boards, + cards) or stackable devices composed of monolithic units in form + <module /stack unit number> - <port number on current module /stack + unit number>, stackable devices in which each unit is composed of + modules + <stack unit number> - <module number> - <port number>" + ::= { rlPhdPortsEntry 2 } + +rlPhdPortsMediaType OBJECT-TYPE + SYNTAX INTEGER {copper(1), optic-fiber(2), combo(3)} + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The media type of this port." + ::= { rlPhdPortsEntry 3 } + +rlPhdPortsStackUnit OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of the slot to which this port belongs." + ::= { rlPhdPortsEntry 4 } + +rlPhdPortsModuleNumber OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of the stack unit to which this port resides in." + ::= { rlPhdPortsEntry 5 } + +rlPhdPortsRow OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "On which row (the uppermost being numbered 1 and the highest row + number asigned to the lowest row) this port resides within its + module." + ::= { rlPhdPortsEntry 6 } + +rlPhdPortsColumn OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "On which column (the leftmost being numbered 1 and the highest column + number asigned to the rightmost column) this this port resides within its + module." + ::= { rlPhdPortsEntry 7 } + +rlPhdConnectorType OBJECT-TYPE + SYNTAX JackType + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Type of connector." + ::= { rlPhdPortsEntry 8 } + + rlPhdPortHaul OBJECT-TYPE + SYNTAX INTEGER { + not-relevant(1), + short(2), + long(3) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Distance supported by this port." + ::= { rlPhdPortsEntry 9 } + +rlPhdStackTable OBJECT-TYPE + SYNTAX SEQUENCE OF RlPhdStackEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "For each stack unit there is an entry describing it in this table" + ::= { rlPhysicalDescription 4 } + +rlPhdStackEntry OBJECT-TYPE + SYNTAX RlPhdStackEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A entry of this table specifies a stack unit" + INDEX { rlPhdStackUnit } + ::= { rlPhdStackTable 1 } + +RlPhdStackEntry ::= SEQUENCE { + rlPhdStackUnit INTEGER, + rlPhdStackType INTEGER, + rlPhdStackConnect1 INTEGER, + rlPhdStackConnect2 INTEGER, + rlPhdStackSofrwareVer DisplayString, + rlPhdStackProductID DisplayString, + rlPhdStackMacAddr PhysAddress +} + +rlPhdStackUnit OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The stack unit described by this entry." + ::= { rlPhdStackEntry 1 } + +rlPhdStackType OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The type of the stack unit described by this entry: + 1 - box 3202 + 2 - box LG + 3 - bcm + 4 - prestera" + ::= { rlPhdStackEntry 2 } + +rlPhdStackConnect1 OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The unit number connected to the Hyper GLink left side connection - + 0 means not connected; other integer indicates the unit number." + DEFVAL { 0 } + ::= { rlPhdStackEntry 3 } + +rlPhdStackConnect2 OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The unit number connected to the Hyper GLink right side connection - + 0 means not connected; other integer indicates the unit number." + DEFVAL { 0 } + ::= { rlPhdStackEntry 4 } + +rlPhdStackSofrwareVer OBJECT-TYPE + SYNTAX DisplayString (SIZE (1..20)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The Software version of the unit." + ::= { rlPhdStackEntry 5 } + +rlPhdStackProductID OBJECT-TYPE + SYNTAX DisplayString (SIZE (1..40)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The Product ID of the unit." + ::= { rlPhdStackEntry 6 } + +rlPhdStackMacAddr OBJECT-TYPE + SYNTAX PhysAddress + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The physical (MAC) address of the unit." + ::= { rlPhdStackEntry 7 } + +rlPhdModuleHotSwapTable OBJECT-TYPE + SYNTAX SEQUENCE OF RlPhdModuleHotSwapEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "For each module (board) there is an entry describing its Hot Swap + status" + ::= { rlPhysicalDescription 5 } + +rlPhdModuleHotSwapEntry OBJECT-TYPE + SYNTAX RlPhdModuleHotSwapEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A entry of this table specifies a module (board) Hot Swap + status" + INDEX { rlPhdModuleStackUnit, rlPhdModuleIndex} + ::= { rlPhdModuleHotSwapTable 1 } + +RlPhdModuleHotSwapEntry ::= SEQUENCE { + rlPhdModuleHotSwapAdminStatus INTEGER, + rlPhdModuleHotSwapOperStatus INTEGER +} + +rlPhdModuleHotSwapAdminStatus OBJECT-TYPE + SYNTAX INTEGER { + on(1), + off(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The desired state of the module. The off(1) state indicates + that the module is not used and its rlPhdModuleHotSwapOperStatus + is always off(2). + The on{1) state indicates that the module may be used and its + rlPhdModuleHotSwapOperStatus will be on(1) if it presents and + off(2) if it does not present." + DEFVAL { on } + ::= { rlPhdModuleHotSwapEntry 1 } + +rlPhdModuleHotSwapOperStatus OBJECT-TYPE + SYNTAX INTEGER { + on(1), + off(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current Hot Swap state of the module. + If rlPhdModuleHotSwapAdminStatus is down(2) then + rlPhdModuleHotSwapOperStatus should be down(2). If + rlPhdModuleHotSwapAdminStatus is changed to up(1) then + rlPhdModuleHotSwapOperStatus should change to + up(1) if the module presents; it should remain in the down(2) state if + and only if the module does not present." + ::= { rlPhdModuleHotSwapEntry 2 } + +rlPhdStackOrderTable OBJECT-TYPE + SYNTAX SEQUENCE OF RlPhdStackOrderEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table enables the user to configure the order + of the stack units as displayed on his GUI. + The order of the entries in this table corresponds + to the last configured order. If the stack units order was + never configured, the order will be the same as in the rlPhdStackTable." + ::= { rlPhysicalDescription 6 } + +rlPhdStackOrderEntry OBJECT-TYPE + SYNTAX RlPhdStackOrderEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A entry of this table specifies a stack unit in the position desired by the user" + INDEX { rlPhdStackOrderCurrentUnitPosition } + ::= { rlPhdStackOrderTable 1 } + +RlPhdStackOrderEntry ::= SEQUENCE { + rlPhdStackOrderCurrentUnitPosition INTEGER, + rlPhdStackOrderDesiredUnitPosition INTEGER, + rlPhdStackOrderUnitIndex INTEGER, + rlPhdStackOrderUnitType INTEGER +} + +rlPhdStackOrderCurrentUnitPosition OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The current stack unit position." + ::= { rlPhdStackOrderEntry 1 } + +rlPhdStackOrderDesiredUnitPosition OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The desired stack unit position. Note that setting this MIB + object will take effect only after setting the rlPhdStackReorder MIB + object below. After setting this MIB object and until a further change + of at least one instance of the rlPhdStackOrderDesiredUnitPosition object, + the values of the rlPhdStackOrderCurrentUnitPosition objectinstance and + the corresponding rlPhdStackOrderDesiredUnitPosition object instance + will be the same." + ::= { rlPhdStackOrderEntry 2 } + +rlPhdStackOrderUnitIndex OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This is the original unit index, i.e. has the same value as rlPhdStackUnit + above." + ::= { rlPhdStackOrderEntry 3 } + +rlPhdStackOrderUnitType OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The type of the stack unit described by this entry. It has the same value + as rlPhdStackType above. This information is duplicated here only for easier + retrieval by the device manager." + ::= { rlPhdStackOrderEntry 4 } + +rlPhdStackReorder OBJECT-TYPE + SYNTAX INTEGER {reorder(1)} + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Setting this MIB object will cause the settings of the + rlPhdStackOrderDesiredUnitPosition MIB object instances to take effect. + After setting this MIB object and until a further change + of at least one instance of the rlPhdStackOrderDesiredUnitPosition object, + the values of the rlPhdStackOrderCurrentUnitPosition objectinstance and + the corresponding rlPhdStackOrderDesiredUnitPosition object instance + will be the same." + ::= { rlPhysicalDescription 7 } + +rlPhdNumberOfUnits OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Shows the current number of units in the stack." + ::= { rlPhysicalDescription 8 } + +rlPhdMaxNumberOfUnits OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Shows the maximum number of units in the stack." + ::= { rlPhysicalDescription 9 } + +rlPhdForceControllerUnit OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Force unit to be controller." + ::= { rlPhysicalDescription 10 } + +-- The following scalar isn't suported and will be removed +rlPhdStackFixedUnit OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Determine which unit will be on bottom/top of list + on Show-List command(see ." + ::= { rlPhysicalDescription 11 } + +-- The following scalar isn't suported and will be removed +rlPhdStackFixedUnitLocation OBJECT-TYPE + SYNTAX INTEGER{ + bottom(1), + top(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Determine the bottom/top object in the stack table." + ::= { rlPhysicalDescription 12 } + +rlPhdStackReloadUnit OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Reset a specific unit." + ::= { rlPhysicalDescription 13 } + +rlPhdUnitGenParamTable OBJECT-TYPE + SYNTAX SEQUENCE OF RlPhdUnitGenParamEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "For each module (board) there is an entry describing it in this + module" + ::= { rlPhysicalDescription 14 } + +rlPhdUnitGenParamEntry OBJECT-TYPE + SYNTAX RlPhdUnitGenParamEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A entry of this table specifies a module (board)" + INDEX { rlPhdUnitGenParamStackUnit} + ::= { rlPhdUnitGenParamTable 1 } + +RlPhdUnitGenParamEntry ::= SEQUENCE { + rlPhdUnitGenParamStackUnit INTEGER, + rlPhdUnitGenParamSoftwareVersion DisplayString, + rlPhdUnitGenParamFirmwareVersion DisplayString, + rlPhdUnitGenParamHardwareVersion DisplayString, + rlPhdUnitGenParamSerialNum DisplayString, + rlPhdUnitGenParamAssetTag DisplayString, + rlPhdUnitGenParamServiceTag DisplayString, + rlPhdUnitGenParamSoftwareDate DisplayString, + rlPhdUnitGenParamFirmwareDate DisplayString, + rlPhdUnitGenParamManufacturer DisplayString, + rlPhdUnitGenParamModelName DisplayString, + rlPhdUnitGenParamMd5ChksumBoot DisplayString, + rlPhdUnitGenParamMd5ChksumImage1 DisplayString, + rlPhdUnitGenParamMd5ChksumImage2 DisplayString, + rlPhdUnitGenParamRegistrationDone TruthValue, + rlPhdUnitGenParamRegistrationSuppressed TruthValue, + rlPhdUnitGenParamCpldVersion DisplayString +} + +rlPhdUnitGenParamStackUnit OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The index of the stack unit to which this conceptual row corresponds." + ::= { rlPhdUnitGenParamEntry 1 } + +rlPhdUnitGenParamSoftwareVersion OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Serial number of the product." + ::= { rlPhdUnitGenParamEntry 2 } + +rlPhdUnitGenParamFirmwareVersion OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Serial number of the product." + ::= { rlPhdUnitGenParamEntry 3 } + +rlPhdUnitGenParamHardwareVersion OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Serial number of the product." + ::= { rlPhdUnitGenParamEntry 4 } + +rlPhdUnitGenParamSerialNum OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Serial number of the product." + ::= { rlPhdUnitGenParamEntry 5 } + +rlPhdUnitGenParamAssetTag OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Serial number of the product." + ::= { rlPhdUnitGenParamEntry 6 } + +rlPhdUnitGenParamServiceTag OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Asset tag of the product." + ::= { rlPhdUnitGenParamEntry 7 } + +rlPhdUnitGenParamSoftwareDate OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Date of product's software." + ::= { rlPhdUnitGenParamEntry 8 } + +rlPhdUnitGenParamFirmwareDate OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Date of product's firmware." + ::= { rlPhdUnitGenParamEntry 9 } + +rlPhdUnitGenParamManufacturer OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Product's Manufacturer." + ::= { rlPhdUnitGenParamEntry 10 } + +rlPhdUnitGenParamModelName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Model Name." + ::= { rlPhdUnitGenParamEntry 11 } + +rlPhdUnitGenParamMd5ChksumBoot OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "MD5 Checksum for Boot" + ::= { rlPhdUnitGenParamEntry 12 } + +rlPhdUnitGenParamMd5ChksumImage1 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "MD5 Checksum for Image 1" + ::= { rlPhdUnitGenParamEntry 13 } + +rlPhdUnitGenParamMd5ChksumImage2 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "MD5 Checksum for Image 2" + ::= { rlPhdUnitGenParamEntry 14 } + +rlPhdUnitGenParamRegistrationDone OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Registration Done." + ::= { rlPhdUnitGenParamEntry 15 } + +rlPhdUnitGenParamRegistrationSuppressed OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Registration Suppressed." + ::= { rlPhdUnitGenParamEntry 16 } + +rlPhdUnitGenParamCpldVersion OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "CPLD version" + ::= { rlPhdUnitGenParamEntry 17 } + + + + +rlPhdUnitEnvParamTable OBJECT-TYPE + SYNTAX SEQUENCE OF RlPhdUnitEnvParamEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "For each module (board) there is an entry describing it in this + module" + ::= { rlPhysicalDescription 15 } + +rlPhdUnitEnvParamEntry OBJECT-TYPE + SYNTAX RlPhdUnitEnvParamEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A entry of this table specifies a module (board)" + INDEX { rlPhdUnitEnvParamStackUnit} + ::= { rlPhdUnitEnvParamTable 1 } + +RlPhdUnitEnvParamEntry ::= SEQUENCE { + rlPhdUnitEnvParamStackUnit INTEGER, + rlPhdUnitEnvParamMainPSStatus RlEnvMonState, + rlPhdUnitEnvParamRedundantPSStatus RlEnvMonState, + rlPhdUnitEnvParamFan1Status RlEnvMonState, + rlPhdUnitEnvParamFan2Status RlEnvMonState, + rlPhdUnitEnvParamFan3Status RlEnvMonState, + rlPhdUnitEnvParamFan4Status RlEnvMonState, + rlPhdUnitEnvParamFan5Status RlEnvMonState, + rlPhdUnitEnvParamFan6Status RlEnvMonState, + rlPhdUnitEnvParamTempSensorValue EntitySensorValue, + rlPhdUnitEnvParamTempSensorStatus EntitySensorStatus, + rlPhdUnitEnvParamTempSensorWarningThresholdValue EntitySensorValue, + rlPhdUnitEnvParamTempSensorCriticalThresholdValue EntitySensorValue, + rlPhdUnitEnvParamUpTime TimeTicks, + rlPhdUnitEnvParamMonitorAutoRecoveryEnable TruthValue, + rlPhdUnitEnvParamMonitorTemperatureStatus INTEGER, + rlPhdUnitEnvParamMonitorOperStatus TruthValue, + rlPhdUnitEnvParamFan1Speed Unsigned32, + rlPhdUnitEnvParamFan2Speed Unsigned32, + rlPhdUnitEnvParamFan3Speed Unsigned32, + rlPhdUnitEnvParamFan4Speed Unsigned32, + rlPhdUnitEnvParamFan5Speed Unsigned32, + rlPhdUnitEnvParamFan6Speed Unsigned32 +} + +rlPhdUnitEnvParamStackUnit OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The index of the stack unit to which this conceptual row corresponds. + Note that the index will be the same index as the index + of a 'chassis' physical entity in the entity MIB of the product." + ::= { rlPhdUnitEnvParamEntry 1 } + +rlPhdUnitEnvParamMainPSStatus OBJECT-TYPE + SYNTAX RlEnvMonState + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The mandatory state of the main PS being instrumented." + ::= { rlPhdUnitEnvParamEntry 2 } + +rlPhdUnitEnvParamRedundantPSStatus OBJECT-TYPE + SYNTAX RlEnvMonState + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The mandatory state of the redundant PS being instrumented." + ::= { rlPhdUnitEnvParamEntry 3 } + +rlPhdUnitEnvParamFan1Status OBJECT-TYPE + SYNTAX RlEnvMonState + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The mandatory state of the FAN 1 being instrumented." + ::= { rlPhdUnitEnvParamEntry 4 } + +rlPhdUnitEnvParamFan2Status OBJECT-TYPE + SYNTAX RlEnvMonState + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The mandatory state of the FAN 2 being instrumented." + ::= { rlPhdUnitEnvParamEntry 5 } + +rlPhdUnitEnvParamFan3Status OBJECT-TYPE + SYNTAX RlEnvMonState + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The mandatory state of the FAN 3 being instrumented." + ::= { rlPhdUnitEnvParamEntry 6 } + +rlPhdUnitEnvParamFan4Status OBJECT-TYPE + SYNTAX RlEnvMonState + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The mandatory state of the FAN 4 being instrumented." + ::= { rlPhdUnitEnvParamEntry 7 } + +rlPhdUnitEnvParamFan5Status OBJECT-TYPE + SYNTAX RlEnvMonState + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The mandatory state of the FAN 5 being instrumented." + ::= { rlPhdUnitEnvParamEntry 8 } + +rlPhdUnitEnvParamFan6Status OBJECT-TYPE + SYNTAX RlEnvMonState + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The mandatory state of the FAN 6 being instrumented." + ::= { rlPhdUnitEnvParamEntry 9 } + +rlPhdUnitEnvParamTempSensorValue OBJECT-TYPE + SYNTAX EntitySensorValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current value for the Sensor being instrumented." + ::= { rlPhdUnitEnvParamEntry 10 } + +rlPhdUnitEnvParamTempSensorStatus OBJECT-TYPE + SYNTAX EntitySensorStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Status value for the Sensor being instrumented." + ::= { rlPhdUnitEnvParamEntry 11 } + +rlPhdUnitEnvParamTempSensorWarningThresholdValue OBJECT-TYPE + SYNTAX EntitySensorValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Temperature warning threshold value for the Sensor being instrumented." + ::= { rlPhdUnitEnvParamEntry 12 } + +rlPhdUnitEnvParamTempSensorCriticalThresholdValue OBJECT-TYPE + SYNTAX EntitySensorValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Temperature critical threshold value for the Sensor being instrumented." + ::= { rlPhdUnitEnvParamEntry 13 } + +rlPhdUnitEnvParamUpTime OBJECT-TYPE + SYNTAX TimeTicks + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Up time of the unit in 100th of second (sec/100)." + ::= { rlPhdUnitEnvParamEntry 14 } + +rlPhdUnitEnvParamMonitorAutoRecoveryEnable OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Disable environment automatic recovery option" + ::= { rlPhdUnitEnvParamEntry 15 } + +rlPhdUnitEnvParamMonitorTemperatureStatus OBJECT-TYPE + SYNTAX INTEGER { + ok(1), + overTemperatureThreshold(2), + overCriticalTemperatureThreshold(3) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Display environment monitoring chassis temperature status" + ::= { rlPhdUnitEnvParamEntry 16 } + +rlPhdUnitEnvParamMonitorOperStatus OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Display environment automatic recovery current status (active/not active)" + ::= { rlPhdUnitEnvParamEntry 17 } + +rlPhdUnitEnvParamFan1Speed OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Rotation speed of FAN 1 in RPM. Value 4294967295 means the measurement of speed is not supported." + ::= { rlPhdUnitEnvParamEntry 18 } + +rlPhdUnitEnvParamFan2Speed OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Rotation speed of FAN 2 in RPM. Value 4294967295 means the measurement of speed is not supported." + ::= { rlPhdUnitEnvParamEntry 19 } + +rlPhdUnitEnvParamFan3Speed OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Rotation speed of FAN 3 in RPM. Value 4294967295 means the measurement of speed is not supported." + ::= { rlPhdUnitEnvParamEntry 20 } + +rlPhdUnitEnvParamFan4Speed OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Rotation speed of FAN 4 in RPM. Value 4294967295 means the measurement of speed is not supported." + ::= { rlPhdUnitEnvParamEntry 21 } + +rlPhdUnitEnvParamFan5Speed OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Rotation speed of FAN 5 in RPM. Value 4294967295 means the measurement of speed is not supported." + ::= { rlPhdUnitEnvParamEntry 22 } + +rlPhdUnitEnvParamFan6Speed OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Rotation speed of FAN 6 in RPM. Value 4294967295 means the measurement of speed is not supported." + ::= { rlPhdUnitEnvParamEntry 23 } + +rlPhdStackOrderTopUnit OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This scalar mib holds the Top unit for the stack order command" + ::= { rlPhysicalDescription 16 } + +rlPhdStackOrderBottomUnit OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This scalar mib holds the Bottom unit for the stack order command" + ::= { rlPhysicalDescription 17 } +rlPhdStackOrderPermutation OBJECT-TYPE + SYNTAX OCTET STRING(SIZE(1..32)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This scalar mib holds stack permutation" + ::= { rlPhysicalDescription 18 } + +rlPhdNumberOfPoeUnits OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Shows the current number of poe units in the stack." + ::= { rlPhysicalDescription 19 } + +rlPhdPoeTable OBJECT-TYPE + SYNTAX SEQUENCE OF RlPhdPoeEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "For each module (board) there is an entry describing it in this + module" + ::= { rlPhysicalDescription 20 } + +rlPhdPoeEntry OBJECT-TYPE + SYNTAX RlPhdPoeEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A entry of this table specifies a module (board)" + INDEX { rlPhdPoeStackUnit } + ::= { rlPhdPoeTable 1 } + +RlPhdPoeEntry ::= SEQUENCE { + rlPhdPoeStackUnit INTEGER, + rlPhdPoePresent INTEGER +} + +rlPhdPoeStackUnit OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The stack unit to which this module belongs." + ::= { rlPhdPoeEntry 1 } + +rlPhdPoePresent OBJECT-TYPE + SYNTAX INTEGER { + no(1), + yes(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The present state of the PoE module. The no(1) state indicates + that the PoE module is not present. The yes{2) state indicates that the + PoE module is present." + ::= { rlPhdPoeEntry 2 } + +-- The light unit scalars +rlPhdPhyLedStackUnit OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This scalar mib holds the unit number for the stack light command" + ::= { rlPhysicalDescription 21 } + +rlPhdPhyLedTimeout OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This scalar mib holds the timeout for the stack light command. + May be in the range 2..60 sec. (default - 5 sec.), if the timeout = 0 + - all units return to normal state." + ::= { rlPhysicalDescription 22 } + +rlCascadeTable OBJECT-TYPE + SYNTAX SEQUENCE OF RlCascadeEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "For each cascaded port for stacking unit there is an entry describing it in this table" + ::= { rlPhysicalDescription 23 } + +rlCascadeEntry OBJECT-TYPE + SYNTAX RlCascadeEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry of this table specifies a cascaded link information in a unit" + INDEX { ifIndex } + ::= { rlCascadeTable 1 } + +RlCascadeEntry ::= SEQUENCE { + rlCascadeNeighborIfIndex InterfaceIndexOrZero, + rlCascadeNeighborUnit INTEGER, + rlCascadeTrunkId INTEGER, + rlCascadeUnitId INTEGER, + rlCascadePortSpeed CascadePortSpeed, + rlCascadePortState CascadePortState +} + +rlCascadeNeighborIfIndex OBJECT-TYPE + SYNTAX InterfaceIndexOrZero + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The ifIndex of a stacking port in the neighbor unit - + 0 means not connected; other integer indicates the IfIndex." + ::= { rlCascadeEntry 1 } + +rlCascadeNeighborUnit OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The unit number of the neighbor unit - + 0 means not connected; other integer indicates the unit number." + ::= { rlCascadeEntry 2 } + +rlCascadeTrunkId OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The id of the trunk, the stacking port is member, + zero if the port is not member of trunk." + ::= { rlCascadeEntry 3 } + +rlCascadeUnitId OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The unit number matching the current ifIndex" + ::= { rlCascadeEntry 4 } + +rlCascadePortSpeed OBJECT-TYPE + SYNTAX CascadePortSpeed + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Port speed" + ::= { rlCascadeEntry 5 } + +rlCascadePortState OBJECT-TYPE + SYNTAX CascadePortState + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Port state according to cascade LAG state machine" + ::= { rlCascadeEntry 6 } + +-- rlCascadeAdminTable -- + +rlCascadeAdminTable OBJECT-TYPE + SYNTAX SEQUENCE OF RlCascadeAdminEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "For each unit there is an entry describing its cascade ports and speed after reset" + ::= { rlPhysicalDescription 24 } + +rlCascadeAdminEntry OBJECT-TYPE + SYNTAX RlCascadeAdminEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry of this table specifies a cascaded information in a unit after reset" + INDEX { rlCascadeAdminUnitId } + ::= { rlCascadeAdminTable 1 } + +RlCascadeAdminEntry ::= SEQUENCE { + rlCascadeAdminUnitId INTEGER, + rlCascadeAdminIndexList OCTET STRING, + rlCascadeAdminSpeed CascadePortSpeed +} + +rlCascadeAdminUnitId OBJECT-TYPE + SYNTAX INTEGER (0|1..8) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The active unit number. Unit id 0 means configure all units." + ::= { rlCascadeAdminEntry 1 } + +rlCascadeAdminIndexList OBJECT-TYPE + SYNTAX OCTET STRING (SIZE (1..16)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Indicates the stack ports indexes list. + A set of indexes that are identified by a bit-map, in which + each index is represented as a bit." + ::= { rlCascadeAdminEntry 2 } + +rlCascadeAdminSpeed OBJECT-TYPE + SYNTAX CascadePortSpeed + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Cascade port speed" + ::= { rlCascadeAdminEntry 3 } + +-- Stack MIB Trap Definitions + +rlStackUnitRemoved NOTIFICATION-TYPE + OBJECTS { rndErrorDesc, rndErrorSeverity } + STATUS current + DESCRIPTION + "Trap indicating that a unit was removed from the stack." + ::= { rndNotifications 186 } + +rlStackConfigChangedRingChain NOTIFICATION-TYPE + OBJECTS { rndErrorDesc, rndErrorSeverity } + STATUS current + DESCRIPTION + "Trap indicating that the configuration of the stack has changed. + - from ring to chain + - from chain to ring." + + ::= { rndNotifications 187 } + +rlStackBackupUnitRemoved NOTIFICATION-TYPE + OBJECTS { rndErrorDesc, rndErrorSeverity } + STATUS current + DESCRIPTION + "Trap indicating that the backup unit was removed from the stack." + ::= { rndNotifications 188 } + +rlStackControllerSwitchover NOTIFICATION-TYPE + OBJECTS { rndErrorDesc, rndErrorSeverity } + STATUS current + DESCRIPTION + "Trap indicating that a new controller was elected. + The old maste is the backup now. " + ::= { rndNotifications 189 } + +rlStackUnitDifferentSwVersion NOTIFICATION-TYPE + OBJECTS { rndErrorDesc, rndErrorSeverity } + STATUS current + DESCRIPTION + "Trap indicating that the new unit added to the stack has + different software version than the controller." + ::= { rndNotifications 190 } + +rlStackDuplicateUnitNotJoin NOTIFICATION-TYPE + OBJECTS { rndErrorDesc, rndErrorSeverity } + STATUS current + DESCRIPTION + "Trap indicating that a new unit with duplicated unit id was + added to the stack - but it will not join the stack." + ::= { rndNotifications 191 } + +rlStackLinkChange NOTIFICATION-TYPE + OBJECTS { rndErrorDesc, rndErrorSeverity } + STATUS current + DESCRIPTION + "Trap indicating that Link has change in one of the Stacking Ports." + ::= { rndNotifications 195 } + + +---------------------- +-- rlPhdUnitStackTable +---------------------- + +StackPortType ::= INTEGER { + port-type-100M (0), + port-type-1G (1), + port-type-5G (2), + port-type-10G (3) +} + +ConnectionType ::= INTEGER { + copper (1), + combo-copper (2), + combo-fiber (3), + fiber (4), + direct-attached (5) +} + + +rlPhdUnitStackPortTable OBJECT-TYPE + SYNTAX SEQUENCE OF RlPhdUnitStackPortEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The table listing information required for stack port. + The index for the table is ifindex; the ports that represented in that table are + operational stack ports or ports that can be stack ports after reset" + ::= { rlPhysicalDescription 25} + +rlPhdUnitStackPortEntry OBJECT-TYPE + SYNTAX RlPhdUnitStackPortEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry in rlPhdUnitStackPortTable " + INDEX { rlPhdModuleStackUnit, ifIndex } + ::= { rlPhdUnitStackPortTable 1 } + + +RlPhdUnitStackPortEntry::= SEQUENCE { + rlPhdUnitStackPortName DisplayString, + rlPhdUnitStackPortType StackPortType, + rlPhdUnitStackPortConnectionType ConnectionType, + rlPhdUnitStackPortColumn INTEGER, + rlPhdUnitStackPortRow INTEGER +} + +rlPhdUnitStackPortName OBJECT-TYPE + SYNTAX DisplayString (SIZE(1..50)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Stack port name" + ::= { rlPhdUnitStackPortEntry 1 } + +rlPhdUnitStackPortType OBJECT-TYPE + SYNTAX StackPortType + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Stack port type" + ::= { rlPhdUnitStackPortEntry 2 } + +rlPhdUnitStackPortConnectionType OBJECT-TYPE + SYNTAX ConnectionType + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Operational connection type + (copper(1), combo-copper(2), combo-fiber(3), fiber(4), direct-Attached(5))" + ::= { rlPhdUnitStackPortEntry 3 } + +rlPhdUnitStackPortRow OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "On which row (the uppermost being numbered 1 and the highest row + number assigned to the lowest row) this actual/candidate cascade + port resides within the chassis of its stack unit." + ::= { rlPhdUnitStackPortEntry 4 } + +rlPhdUnitStackPortColumn OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "On which column (the leftmost being numbered 1 and the highest column + number assigned to the rightmost column) this actual/candidate cascade + port resides within the chassis of its stack unit." + ::= { rlPhdUnitStackPortEntry 5 } + + +rlPhdUnitIfsMappingTable OBJECT-TYPE + SYNTAX SEQUENCE OF RlPhdUnitIfsMappingEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Unit Interface Mapping description table." + ::= { rlPhysicalDescription 26 } + +rlPhdUnitIfsMappingEntry OBJECT-TYPE + SYNTAX RlPhdUnitIfsMappingEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Unit Interface Mapping description entry" + INDEX { rlPhdUnitIfsMappingUnitId} + ::= { rlPhdUnitIfsMappingTable 1 } + +RlPhdUnitIfsMappingEntry ::= SEQUENCE { + rlPhdUnitIfsMappingUnitId INTEGER, + rlPhdUnitIfsMappingUnitType INTEGER +} + +rlPhdUnitIfsMappingUnitId OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "Unit Id" + ::= { rlPhdUnitIfsMappingEntry 1 } + +rlPhdUnitIfsMappingUnitType OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Actual unit type used for interface mapping." + ::= { rlPhdUnitIfsMappingEntry 2 } + +rlPhdPhyLedTimeRemaining OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This scalar mib holds the time remaining for the stack light command timout to expire. + May be in the range 0..300 seconds, if the timeout = 0 + - stack light command timeour expired." + ::= { rlPhysicalDescription 27 } + +rlPhdPhyLedPattern OBJECT-TYPE + SYNTAX LedLocatorPattern + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This scalar mib holds the pattern configuration required for the stack light command." + ::= { rlPhysicalDescription 28 } + +END |