diff options
| author | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
|---|---|---|
| committer | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
| commit | 98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch) | |
| tree | 9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/dasan/SLE-DEVICE-MIB | |
| download | mibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.tar.gz mibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.zip | |
Diffstat (limited to 'MIBS/dasan/SLE-DEVICE-MIB')
| -rw-r--r-- | MIBS/dasan/SLE-DEVICE-MIB | 7218 |
1 files changed, 7218 insertions, 0 deletions
diff --git a/MIBS/dasan/SLE-DEVICE-MIB b/MIBS/dasan/SLE-DEVICE-MIB new file mode 100644 index 0000000..fba8423 --- /dev/null +++ b/MIBS/dasan/SLE-DEVICE-MIB @@ -0,0 +1,7218 @@ +--
+-- SLE-DEVICE-MIB.my
+-- MIB generated by MG-SOFT Visual MIB Builder Version 6.0 Build 88
+-- Friday, March 18, 2016 at 15:23:50
+--
+
+ SLE-DEVICE-MIB DEFINITIONS ::= BEGIN
+
+ IMPORTS
+ sleMgmt
+ FROM DASAN-SMI
+ SleControlStatusType, SleControlRequestResultType
+ FROM SLE-TC-MIB
+ OBJECT-GROUP, NOTIFICATION-GROUP
+ FROM SNMPv2-CONF
+ TimeTicks, IpAddress, Integer32, Unsigned32, Gauge32,
+ BITS, OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE
+ FROM SNMPv2-SMI;
+
+
+ sleDevice MODULE-IDENTITY
+ LAST-UPDATED "200412100852Z" -- December 10, 2004 at 08:52 GMT
+ ORGANIZATION
+ "Organization."
+ CONTACT-INFO
+ "Contact-info."
+ DESCRIPTION
+ "Description."
+ ::= { sleMgmt 2 }
+
+
+
+
+--
+-- Node definitions
+--
+
+ sleDeviceBase OBJECT IDENTIFIER ::= { sleDevice 1 }
+
+
+ sleDeviceBaseInfo OBJECT IDENTIFIER ::= { sleDeviceBase 1 }
+
+
+ sleDeviceEthernetPortNum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of ethernet port."
+ ::= { sleDeviceBaseInfo 1 }
+
+
+ sleDevicePowerNum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of power module"
+ ::= { sleDeviceBaseInfo 2 }
+
+
+ sleDeviceFanModuleNum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of FAN module"
+ ::= { sleDeviceBaseInfo 3 }
+
+
+ sleDeviceTemperatureNum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of temperature sensor"
+ ::= { sleDeviceBaseInfo 4 }
+
+
+ sleDeviceFanStartTemperature OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The temperature value which begins to turn fan."
+ ::= { sleDeviceBaseInfo 5 }
+
+
+ sleDeviceFanStopTemperature OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The temperature value which stops fan."
+ ::= { sleDeviceBaseInfo 6 }
+
+
+ sleDeviceJumboFrameStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ enable(1),
+ disable(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The global jumbo-frame status.
+ 2011/01/20 V5924CR only support this."
+ ::= { sleDeviceBaseInfo 7 }
+
+
+ sleDeviceEnvironmentMonitoringStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ notInstallAIU(0),
+ normalOpen(1),
+ normalClose(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The alarm input mode of environment monitoring for AIU"
+ ::= { sleDeviceBaseInfo 8 }
+
+
+ sleDeviceBaseControl OBJECT IDENTIFIER ::= { sleDeviceBase 2 }
+
+
+ sleDeviceControlRequest OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ setDeviceTemperatureThreshold(1),
+ setDeviceJumboFrameStatus(2),
+ setDeviceLEDTest(3),
+ setEnvironmentMonitoringStatus(4)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "set an administrative state of FAN module"
+ ::= { sleDeviceBaseControl 1 }
+
+
+ sleDeviceControlStatus OBJECT-TYPE
+ SYNTAX SleControlStatusType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleDeviceBaseControl 2 }
+
+
+ sleDeviceControlTimer OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleDeviceBaseControl 3 }
+
+
+ sleDeviceControlTimeStamp OBJECT-TYPE
+ SYNTAX TimeTicks
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleDeviceBaseControl 4 }
+
+
+ sleDeviceControlReqResult OBJECT-TYPE
+ SYNTAX SleControlRequestResultType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleDeviceBaseControl 5 }
+
+
+ sleDeviceControlFanStartTemperature OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleDeviceBaseControl 6 }
+
+
+ sleDeviceControlFanStopTemperature OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleDeviceBaseControl 7 }
+
+
+ sleDeviceControlJumboFrameStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ enable(1),
+ disable(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The global jumbo-frame status.
+ 2011/01/20 V5924CR only support this."
+ ::= { sleDeviceBaseControl 8 }
+
+
+ sleDeviceControlEnvironmentMonitoringStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ normalOpen(1),
+ normalClose(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The alarm input mode of environment monitoring for AIU"
+ ::= { sleDeviceBaseControl 9 }
+
+
+ sleDeviceBaseNotification OBJECT IDENTIFIER ::= { sleDeviceBase 3 }
+
+
+ sleDeviceTemperatureThresholdChanged NOTIFICATION-TYPE
+ OBJECTS { sleDeviceFanStartTemperature, sleDeviceFanStopTemperature, sleDeviceControlRequest, sleDeviceControlTimeStamp, sleDeviceControlReqResult
+ }
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleDeviceBaseNotification 1 }
+
+
+ sleDeviceJumboFrameChanged NOTIFICATION-TYPE
+ OBJECTS { sleDeviceControlRequest, sleDeviceControlTimeStamp, sleDeviceControlReqResult, sleDeviceControlJumboFrameStatus }
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleDeviceBaseNotification 2 }
+
+
+ sleDeviceLEDTestChanged NOTIFICATION-TYPE
+ OBJECTS { sleDeviceControlRequest, sleDeviceControlTimeStamp, sleDeviceControlReqResult }
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleDeviceBaseNotification 3 }
+
+
+ sleDeviceEnvironmentMonitoringStatusChanged NOTIFICATION-TYPE
+ OBJECTS { sleDeviceControlRequest, sleDeviceControlTimeStamp, sleDeviceControlReqResult, sleDeviceEnvironmentMonitoringStatus }
+ STATUS current
+ DESCRIPTION
+ "setEnvironmentMonitoringStatus "
+ ::= { sleDeviceBaseNotification 4 }
+
+
+ sleEthernetPort OBJECT IDENTIFIER ::= { sleDevice 2 }
+
+
+ sleEthernetPortTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SleEthernetPortEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleEthernetPort 1 }
+
+
+ sleEthernetPortEntry OBJECT-TYPE
+ SYNTAX SleEthernetPortEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Description."
+ INDEX { sleEthernetPortIndex }
+ ::= { sleEthernetPortTable 1 }
+
+
+ SleEthernetPortEntry ::=
+ SEQUENCE {
+ sleEthernetPortIndex
+ INTEGER,
+ sleEthernetPortPhyIndex
+ Integer32,
+ sleEthernetPortType
+ INTEGER,
+ sleEthernetPortAdminStatus
+ INTEGER,
+ sleEthernetPortOperStatus
+ INTEGER,
+ sleEthernetPortTransmissionRate
+ Integer32,
+ sleEthernetPortDuplexMode
+ INTEGER,
+ sleEthernetPortFlowControl
+ INTEGER,
+ sleEthernetPortNegotiationMode
+ INTEGER,
+ sleEthernetPortJumboFrameSize
+ Integer32,
+ sleEthernetPortSfpTransceiver
+ INTEGER,
+ sleEthernetPortSfpVendorName
+ OCTET STRING,
+ sleEthernetPortSfpVendorPartNumber
+ OCTET STRING,
+ sleEthernetPortSfpVendorRevision
+ OCTET STRING,
+ sleEthernetPortSfpVendorSerialNumber
+ OCTET STRING,
+ sleEthernetPortSfpDateCode
+ OCTET STRING,
+ sleEthernetPortPhysicalRemoteChassis
+ OCTET STRING,
+ sleEthernetPortPhysicalRemoteSlot
+ Integer32,
+ sleEthernetPortPhysicalRemotePort
+ Integer32,
+ sleEthernetPortPhysicalLinkDiscoveryMode
+ INTEGER,
+ sleEthernetPortSfpTransceiverType
+ INTEGER,
+ sleEthernetPortSfpTransceiverDetailType
+ INTEGER,
+ sleEthernetPortSlotIndex
+ Integer32,
+ sleEthernetPortSlotPortIndex
+ Integer32,
+ sleEthernetPortAdminTransmissionRate
+ Integer32,
+ sleEthernetPortAdminDuplexMode
+ INTEGER,
+ sleEthernetPortAdminFlowControl
+ INTEGER,
+ sleEthernetPortAdminNegotiationMode
+ INTEGER,
+ sleEthernetPortAdminReason
+ INTEGER,
+ sleEthernetPortLinkCheckTimer
+ Integer32,
+ sleEthernetPortLinkDebounceTime
+ Integer32,
+ sleEthernetPortCpuStatisticsLimitUnicast
+ Integer32,
+ sleEthernetPortCpuStatisticsLimitMulticast
+ Integer32,
+ sleEthernetPortCpuStatisticsLimitBroadcast
+ Integer32,
+ sleEthernetPortFloodBlockBroadcastState
+ INTEGER,
+ sleEthernetPortFloodBlockDlfState
+ INTEGER
+ }
+
+ sleEthernetPortIndex OBJECT-TYPE
+ SYNTAX INTEGER (1..255)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The port index."
+ ::= { sleEthernetPortEntry 1 }
+
+
+ sleEthernetPortPhyIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The physical index of entity mib."
+ ::= { sleEthernetPortEntry 2 }
+
+
+ sleEthernetPortType OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ unknown(0),
+ electrical(1),
+ optical(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The type of port.
+ It is not planed to made a automatic switchover between optical and electrical interfaces."
+ ::= { sleEthernetPortEntry 3 }
+
+
+ sleEthernetPortAdminStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ up(1),
+ down(2),
+ notAvailable(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The admin status of port."
+ ::= { sleEthernetPortEntry 4 }
+
+
+ sleEthernetPortOperStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ up(1),
+ down(2),
+ notAvailable(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The oper status of port"
+ ::= { sleEthernetPortEntry 5 }
+
+
+ sleEthernetPortTransmissionRate OBJECT-TYPE
+ SYNTAX Integer32 (10 | 100 | 1000 | 2500 | 10000)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The speed of port. Unit is Mbit/s.
+ This configurations are only useful for electrical interfaces.
+ Optical - interfaces will always support 1000 MBIT/s"
+ ::= { sleEthernetPortEntry 6 }
+
+
+ sleEthernetPortDuplexMode OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ full(1),
+ half(2),
+ notAvailable(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The duplex status of port."
+ ::= { sleEthernetPortEntry 7 }
+
+
+ sleEthernetPortFlowControl OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ disabled(1),
+ enabledSymetrical(2),
+ enabledAsymetrical(3),
+ enabledBoth(4),
+ notAvailable(5)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The flow-control mode of port."
+ ::= { sleEthernetPortEntry 8 }
+
+
+ sleEthernetPortNegotiationMode OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ auto(1),
+ force(2),
+ notAvailable(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The Auto Negotiation mode of port. "
+ ::= { sleEthernetPortEntry 9 }
+
+
+ sleEthernetPortJumboFrameSize OBJECT-TYPE
+ SYNTAX Integer32 (0 | 1518..12288)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The jumbo frame's size of port.
+ If the value is zero, it means that it is not set up."
+ ::= { sleEthernetPortEntry 10 }
+
+
+ sleEthernetPortSfpTransceiver OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ unknown(0),
+ electrical(1),
+ electricalCoaxial(2),
+ opticalLongHaul(3),
+ opticalShortHaul(4),
+ optical10G(5),
+ opticalGpon(6)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleEthernetPortEntry 11 }
+
+
+ sleEthernetPortSfpVendorName OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleEthernetPortEntry 12 }
+
+
+ sleEthernetPortSfpVendorPartNumber OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleEthernetPortEntry 13 }
+
+
+ sleEthernetPortSfpVendorRevision OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleEthernetPortEntry 14 }
+
+
+ sleEthernetPortSfpVendorSerialNumber OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleEthernetPortEntry 15 }
+
+
+ sleEthernetPortSfpDateCode OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleEthernetPortEntry 16 }
+
+
+ sleEthernetPortPhysicalRemoteChassis OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleEthernetPortEntry 17 }
+
+
+ sleEthernetPortPhysicalRemoteSlot OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleEthernetPortEntry 18 }
+
+
+ sleEthernetPortPhysicalRemotePort OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleEthernetPortEntry 19 }
+
+
+ sleEthernetPortPhysicalLinkDiscoveryMode OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ none(1),
+ manual(2),
+ automatic(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleEthernetPortEntry 20 }
+
+
+ sleEthernetPortSfpTransceiverType OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ sfp(1),
+ gbit(2),
+ xfp(3),
+ unknown(255)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The type of SFP transceiver."
+ ::= { sleEthernetPortEntry 21 }
+
+
+ sleEthernetPortSfpTransceiverDetailType OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ fiber1000Sx(1),
+ fiber1000Lx(2),
+ fiber1000Cx(3),
+ fiber1000T(4),
+ fiber100lLxLx10(5),
+ fiber100Fx(6),
+ fiberBx10(7),
+ fiberPx(8),
+ fiberOc3MmSr(9),
+ fiberOc3SmIr(10),
+ fiberOc3SmLr(11),
+ fiber1000Zx(12),
+ unknown(255)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The detailed-type of SFP transceiver."
+ ::= { sleEthernetPortEntry 22 }
+
+
+ sleEthernetPortSlotIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The slot index."
+ ::= { sleEthernetPortEntry 23 }
+
+
+ sleEthernetPortSlotPortIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The slot's port index."
+ ::= { sleEthernetPortEntry 24 }
+
+
+ sleEthernetPortAdminTransmissionRate OBJECT-TYPE
+ SYNTAX Integer32 (10 | 100 | 1000 | 10000)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The speed of port. Unit is Mbit/s.
+ This configurations are only useful for electrical interfaces.
+ Optical - interfaces will always support 1000 MBIT/s"
+ ::= { sleEthernetPortEntry 25 }
+
+
+ sleEthernetPortAdminDuplexMode OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ full(1),
+ half(2),
+ notAvailable(255)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The duplex status of port."
+ ::= { sleEthernetPortEntry 26 }
+
+
+ sleEthernetPortAdminFlowControl OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ disabled(1),
+ enableSend(2),
+ enableReceive(3),
+ enabledBoth(4)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The flow-control mode of port."
+ ::= { sleEthernetPortEntry 27 }
+
+
+ sleEthernetPortAdminNegotiationMode OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ auto(1),
+ force(2),
+ notAvailable(255)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The Auto Negotiation mode of port. "
+ ::= { sleEthernetPortEntry 28 }
+
+
+ sleEthernetPortAdminReason OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ none(0),
+ user(1),
+ xllcf(2),
+ all(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The admin down reason of the interface.
+ user : by user-configuration
+ xllcf : by xllcf protocol
+ all : both user and xllcf
+ "
+ ::= { sleEthernetPortEntry 29 }
+
+
+ sleEthernetPortLinkCheckTimer OBJECT-TYPE
+ SYNTAX Integer32 (20..1000)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The Link check internval of the interface "
+ ::= { sleEthernetPortEntry 30 }
+
+
+ sleEthernetPortLinkDebounceTime OBJECT-TYPE
+ SYNTAX Integer32 (0 | 10..5000)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The link debounce time of the interface"
+ ::= { sleEthernetPortEntry 31 }
+
+
+ sleEthernetPortCpuStatisticsLimitUnicast OBJECT-TYPE
+ SYNTAX Integer32 (0 | 10..100)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The CPU statistics-limit Unicast Count
+ ( the standard unit : 1000, 10 = 1000 )
+ "
+ ::= { sleEthernetPortEntry 32 }
+
+
+ sleEthernetPortCpuStatisticsLimitMulticast OBJECT-TYPE
+ SYNTAX Integer32 (0 | 10..100)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "et CPU statistics-limit Multicast Count
+ ( the standard unit : 1000, 10 = 1000 )
+ "
+ ::= { sleEthernetPortEntry 33 }
+
+
+ sleEthernetPortCpuStatisticsLimitBroadcast OBJECT-TYPE
+ SYNTAX Integer32 (0 | 10..100)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Set CPU statistics-limit Broadcast Count
+ ( the standard unit : 1000, 10 = 1000 )
+
+ "
+ ::= { sleEthernetPortEntry 34 }
+
+
+ sleEthernetPortFloodBlockBroadcastState OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ disable(0),
+ enable(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The Flood Block Broadcast State of the interface"
+ ::= { sleEthernetPortEntry 35 }
+
+
+ sleEthernetPortFloodBlockDlfState OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ disable(0),
+ enable(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The Flood Block DLF State of the interface"
+ ::= { sleEthernetPortEntry 36 }
+
+
+ sleEthernetPortControl OBJECT IDENTIFIER ::= { sleEthernetPort 2 }
+
+
+ sleEthernetPortControlRequest OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ setEthernetPortProfile(1),
+ setEthernetPortLinkProfile(2),
+ setEhternetPortCpuStatisticsLimitProfile(3),
+ setEthernetPortFloodBlockStateProfile(4)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleEthernetPortControl 1 }
+
+
+ sleEthernetPortControlStatus OBJECT-TYPE
+ SYNTAX SleControlStatusType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleEthernetPortControl 2 }
+
+
+ sleEthernetPortControlTimer OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleEthernetPortControl 3 }
+
+
+ sleEthernetPortControlTimeStamp OBJECT-TYPE
+ SYNTAX TimeTicks
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleEthernetPortControl 4 }
+
+
+ sleEthernetPortControlReqResult OBJECT-TYPE
+ SYNTAX SleControlRequestResultType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleEthernetPortControl 5 }
+
+
+ sleEthernetPortControlIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleEthernetPortControl 6 }
+
+
+ sleEthernetPortControlType OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ unknown(0),
+ electrical(1),
+ optical(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleEthernetPortControl 7 }
+
+
+ sleEthernetPortControlAdminStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ up(1),
+ down(2),
+ notAvailable(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleEthernetPortControl 8 }
+
+
+ sleEthernetPortControlTransmissionRate OBJECT-TYPE
+ SYNTAX Integer32 (10 | 100 | 1000 | 2500 | 10000)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Description.The speed of port. Unit is Mbit/s.
+ This configurations are only useful for electrical interfaces.
+ Optical - interfaces will always support 1000 MBIT/s"
+ ::= { sleEthernetPortControl 9 }
+
+
+ sleEthernetPortControlDuplexMode OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ full(1),
+ half(2),
+ notAvailable(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleEthernetPortControl 10 }
+
+
+ sleEthernetPortControlFlowControl OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ disabled(1),
+ enabledSymetrical(2),
+ enabledAsymetrical(3),
+ enabledBoth(4),
+ notAvailable(5)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleEthernetPortControl 11 }
+
+
+ sleEthernetPortControlNegotiationMode OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ auto(1),
+ force(2),
+ notAvailable(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleEthernetPortControl 12 }
+
+
+ sleEthernetPortControlJumboFrameSize OBJECT-TYPE
+ SYNTAX Integer32 (0 | 1518..12288)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Description. If the value is zero, it means erasing the set-up value.
+ "
+ ::= { sleEthernetPortControl 13 }
+
+
+ sleEthernetPortControlPhysicalRemoteChassis OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleEthernetPortControl 14 }
+
+
+ sleEthernetPortControlPhysicalRemoteSlot OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleEthernetPortControl 15 }
+
+
+ sleEthernetPortControlPhysicalRemotePort OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleEthernetPortControl 16 }
+
+
+ sleEthernetPortControlPhysicalLinkDiscoveryMode OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ none(1),
+ manual(2),
+ automatic(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleEthernetPortControl 17 }
+
+
+ sleEthernetPortControlLinkCheckTimer OBJECT-TYPE
+ SYNTAX Integer32 (20..1000)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The Link check internval of the interface "
+ ::= { sleEthernetPortControl 18 }
+
+
+ sleEthernetPortControlLinkDebounceTime OBJECT-TYPE
+ SYNTAX Integer32 (0 | 10..5000)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The link debounce time of the interface"
+ ::= { sleEthernetPortControl 19 }
+
+
+ sleEthernetPortControlCpuStatisticsLimitUnicast OBJECT-TYPE
+ SYNTAX Integer32 (0 | 10..100)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The CPU statistics-limit Unicast Count
+ ( the standard unit : 1000, 10 = 1000 )
+ "
+ ::= { sleEthernetPortControl 20 }
+
+
+ sleEthernetPortControlCpuStatisticsLimitMulticast OBJECT-TYPE
+ SYNTAX Integer32 (0 | 10..100)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "et CPU statistics-limit Multicast Count
+ ( the standard unit : 1000, 10 = 1000 )
+ "
+ ::= { sleEthernetPortControl 21 }
+
+
+ sleEthernetPortControlCpuStatisticsLimitBroadcast OBJECT-TYPE
+ SYNTAX Integer32 (0 | 10..100)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Set CPU statistics-limit Broadcast Count
+ ( the standard unit : 1000, 10 = 1000 )
+ "
+ ::= { sleEthernetPortControl 22 }
+
+
+ sleEthernetPortControlFloodBlockBroadcastState OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ disable(0),
+ enable(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The Flood Block Broadcast State of the interface"
+ ::= { sleEthernetPortControl 23 }
+
+
+ sleEthernetPortControlFloodBlockDlfState OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ disable(0),
+ enable(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The Flood Block DLF State of the interface"
+ ::= { sleEthernetPortControl 24 }
+
+
+ sleEthernetPortNotification OBJECT IDENTIFIER ::= { sleEthernetPort 3 }
+
+
+ sleEthernetPortChanged NOTIFICATION-TYPE
+ OBJECTS { sleEthernetPortType, sleEthernetPortAdminStatus, sleEthernetPortTransmissionRate, sleEthernetPortDuplexMode, sleEthernetPortFlowControl,
+ sleEthernetPortNegotiationMode, sleEthernetPortJumboFrameSize, sleEthernetPortSfpVendorName, sleEthernetPortSfpVendorPartNumber, sleEthernetPortSfpVendorRevision,
+ sleEthernetPortSfpVendorSerialNumber, sleEthernetPortSfpDateCode, sleEthernetPortPhysicalRemoteChassis, sleEthernetPortPhysicalRemoteSlot, sleEthernetPortPhysicalRemotePort,
+ sleEthernetPortPhysicalLinkDiscoveryMode, sleEthernetPortControlRequest, sleEthernetPortControlTimeStamp, sleEthernetPortControlReqResult }
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleEthernetPortNotification 1 }
+
+
+ sleEthernetPortLinkChanged NOTIFICATION-TYPE
+ OBJECTS { sleEthernetPortControlRequest, sleEthernetPortControlTimeStamp, sleEthernetPortControlReqResult, sleEthernetPortControlIndex, sleEthernetPortControlLinkCheckTimer,
+ sleEthernetPortControlLinkDebounceTime }
+ STATUS current
+ DESCRIPTION
+ "setEthernetPortLinkProfile"
+ ::= { sleEthernetPortNotification 2 }
+
+
+ sleEthernetPortCpuStatisticsLimitChanged NOTIFICATION-TYPE
+ OBJECTS { sleEthernetPortControlRequest, sleEthernetPortControlTimeStamp, sleEthernetPortControlReqResult, sleEthernetPortControlIndex, sleEthernetPortControlCpuStatisticsLimitUnicast,
+ sleEthernetPortControlCpuStatisticsLimitMulticast, sleEthernetPortControlCpuStatisticsLimitBroadcast }
+ STATUS current
+ DESCRIPTION
+ "setEhternetPortCpuStatisticsLimitProfile"
+ ::= { sleEthernetPortNotification 3 }
+
+
+ sleEthernetPortFloodBlockStateChanged NOTIFICATION-TYPE
+ OBJECTS { sleEthernetPortControlRequest, sleEthernetPortControlTimeStamp, sleEthernetPortControlReqResult, sleEthernetPortControlIndex, sleEthernetPortControlFloodBlockBroadcastState,
+ sleEthernetPortControlFloodBlockDlfState }
+ STATUS current
+ DESCRIPTION
+ "setEthernetPortFloodBlockStateProfile"
+ ::= { sleEthernetPortNotification 4 }
+
+
+ sleEthernetPortDMITable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SleEthernetPortDMIEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleEthernetPort 4 }
+
+
+ sleEthernetPortDMIEntry OBJECT-TYPE
+ SYNTAX SleEthernetPortDMIEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Description."
+ INDEX { sleEthernetPortDMIIndex }
+ ::= { sleEthernetPortDMITable 1 }
+
+
+ SleEthernetPortDMIEntry ::=
+ SEQUENCE {
+ sleEthernetPortDMIIndex
+ INTEGER,
+ sleEthernetPortDMITemper
+ OCTET STRING,
+ sleEthernetPortDMIVoltage
+ OCTET STRING,
+ sleEthernetPortDMITxBias
+ OCTET STRING,
+ sleEthernetPortDMITxPower
+ OCTET STRING,
+ sleEthernetPortDMIRxPower
+ OCTET STRING
+ }
+
+ sleEthernetPortDMIIndex OBJECT-TYPE
+ SYNTAX INTEGER (1..255)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Port Index."
+ ::= { sleEthernetPortDMIEntry 1 }
+
+
+ sleEthernetPortDMITemper OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Internally measured module temperature."
+ ::= { sleEthernetPortDMIEntry 2 }
+
+
+ sleEthernetPortDMIVoltage OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Internally measured supply voltage in transceiver."
+ ::= { sleEthernetPortDMIEntry 3 }
+
+
+ sleEthernetPortDMITxBias OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Internally measured TX Bias Current."
+ ::= { sleEthernetPortDMIEntry 4 }
+
+
+ sleEthernetPortDMITxPower OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Measured TX output power."
+ ::= { sleEthernetPortDMIEntry 5 }
+
+
+ sleEthernetPortDMIRxPower OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Measured RX input power."
+ ::= { sleEthernetPortDMIEntry 6 }
+
+
+ sleEthernetSFPTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SleEthernetSFPEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleEthernetPort 5 }
+
+
+ sleEthernetSFPEntry OBJECT-TYPE
+ SYNTAX SleEthernetSFPEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Description."
+ INDEX { sleEthernetSfpIndex }
+ ::= { sleEthernetSFPTable 1 }
+
+
+ SleEthernetSFPEntry ::=
+ SEQUENCE {
+ sleEthernetSfpIndex
+ Integer32,
+ sleEthernetSfpTransceiver
+ INTEGER,
+ sleEthernetSfpVendorName
+ OCTET STRING,
+ sleEthernetSfpVendorPartNumber
+ OCTET STRING,
+ sleEthernetSfpVendorRevision
+ OCTET STRING,
+ sleEthernetSfpVendorSerialNumber
+ OCTET STRING,
+ sleEthernetSfpDateCode
+ OCTET STRING,
+ sleEthernetSfpTransceiverType
+ INTEGER,
+ sleEthernetSfpTransceiverDetailType
+ INTEGER,
+ sleEthernetSfpTransceiverCodes
+ OCTET STRING,
+ sleEthernetSfpSpeed
+ OCTET STRING,
+ sleEthernetSfpLength
+ Integer32,
+ sleEthernetSfpWaveLength
+ Integer32,
+ sleEthernetSfpMultimodeLengthOm1
+ Integer32,
+ sleEthernetSfpMultimodeLengthOm2
+ Integer32,
+ sleEthernetSfpMultimodeLengthOm3
+ Integer32,
+ sleEthernetSfpTransceiverDetailTypeStr
+ OCTET STRING,
+ sleEthernetSfpTransceiverLengthStr
+ OCTET STRING,
+ sleEthernetSfpWaveLengthStr
+ OCTET STRING,
+ sleEthernetSfpConnectorType
+ OCTET STRING,
+ sleEthernetSfpDdmState
+ INTEGER,
+ sleEthernetSfpNegoState
+ INTEGER
+ }
+
+ sleEthernetSfpIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..65556)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The SFP index."
+ ::= { sleEthernetSFPEntry 1 }
+
+
+ sleEthernetSfpTransceiver OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ unknown(0),
+ electrical(1),
+ electricalCoaxial(2),
+ opticalLongHaul(3),
+ opticalShortHaul(4),
+ optical10G(5),
+ opticalGpon(6)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The type of SFP"
+ ::= { sleEthernetSFPEntry 2 }
+
+
+ sleEthernetSfpVendorName OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The vendor name of SFP"
+ ::= { sleEthernetSFPEntry 3 }
+
+
+ sleEthernetSfpVendorPartNumber OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The part number of SFP"
+ ::= { sleEthernetSFPEntry 4 }
+
+
+ sleEthernetSfpVendorRevision OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The revision of SFP"
+ ::= { sleEthernetSFPEntry 5 }
+
+
+ sleEthernetSfpVendorSerialNumber OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The serial number of SFP"
+ ::= { sleEthernetSFPEntry 6 }
+
+
+ sleEthernetSfpDateCode OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The manufacturing date of SFP"
+ ::= { sleEthernetSFPEntry 7 }
+
+
+ sleEthernetSfpTransceiverType OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ sfp(1),
+ gbic(2),
+ xfp(3),
+ unknown(255)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The type of SFP transceiver."
+ ::= { sleEthernetSFPEntry 8 }
+
+
+ sleEthernetSfpTransceiverDetailType OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ fiber1000Sx(1),
+ fiber1000Lx(2),
+ fiber1000Cx(3),
+ fiber1000T(4),
+ fiber100lLxLx10(5),
+ fiber100Fx(6),
+ fiberBx10(7),
+ fiberPx(8),
+ fiberOc3MmSr(9),
+ fiberOc3SmIr(10),
+ fiberOc3SmLr(11),
+ fiber1000Zx(12),
+ base10GSR(64),
+ base10GLR(65),
+ base10GER(66),
+ base10GLRM(67),
+ base10GSW(68),
+ base10GLW(69),
+ base10GEW(70),
+ base10GEWorZW(71),
+ unknown(255)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The detailed-type of SFP transceiver."
+ ::= { sleEthernetSFPEntry 9 }
+
+
+ sleEthernetSfpTransceiverCodes OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (1..8))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The transceiver codes.
+ In case of SFP, reference SFP-8472 Rev 11.0
+ - Table 3.5: Transceiver codes (Address A0h)
+ - Table 3.5a: SONET Compliance Specifiers (A0h)
+ In case of XFP, reference XFP Specification Revision 4.5 (August 31,2005)
+ - Table 40 Transceiver codes
+ "
+ ::= { sleEthernetSFPEntry 10 }
+
+
+ sleEthernetSfpSpeed OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The speed of SFP"
+ ::= { sleEthernetSFPEntry 11 }
+
+
+ sleEthernetSfpLength OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The length of SFP"
+ ::= { sleEthernetSFPEntry 12 }
+
+
+ sleEthernetSfpWaveLength OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The wavelength of SFP"
+ ::= { sleEthernetSFPEntry 13 }
+
+
+ sleEthernetSfpMultimodeLengthOm1 OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The Flame rating is 62.5um(OM1). This is used only for 10G SFP module with multi-mode.
+ ref) 50/125 Multimode Fiber Optic
+ 50/125 is one of the most commonly used multimode optical fiber, the other commonly used is 62.5/125 types.
+ There is a special kind 50/125 multimode fibers, which is called OM3 50/125. People usually refer 62.5/125 as the OM1 MMF,
+ common type 50/125 MMF as OM2, OM3 is also 50/125, but it is different from OM2 because it support 10Gig data transmission.
+ The OM3 50/125 fiber optic cable is also called laser optimized fiber cable.
+ Both OM1 and OM2 multimode cables use the orange color jacket (standard practice for commonly used indoor multimode),
+ OM3 use a special color, which is called Aqua."
+ ::= { sleEthernetSFPEntry 14 }
+
+
+ sleEthernetSfpMultimodeLengthOm2 OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The Flame rating is 50um(OM2). This is used only for 10G SFP module with multi-mode.
+ ref) 50/125 Multimode Fiber Optic
+ 50/125 is one of the most commonly used multimode optical fiber, the other commonly used is 62.5/125 types.
+ There is a special kind 50/125 multimode fibers, which is called OM3 50/125. People usually refer 62.5/125 as the OM1 MMF,
+ common type 50/125 MMF as OM2, OM3 is also 50/125, but it is different from OM2 because it support 10Gig data transmission.
+ The OM3 50/125 fiber optic cable is also called laser optimized fiber cable.
+ Both OM1 and OM2 multimode cables use the orange color jacket (standard practice for commonly used indoor multimode),
+ OM3 use a special color, which is called Aqua."
+ ::= { sleEthernetSFPEntry 15 }
+
+
+ sleEthernetSfpMultimodeLengthOm3 OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The Flame rating is 50um(OM3). This is used only for 10G SFP module with multi-mode.
+ ref) 50/125 Multimode Fiber Optic
+ 50/125 is one of the most commonly used multimode optical fiber, the other commonly used is 62.5/125 types.
+ There is a special kind 50/125 multimode fibers, which is called OM3 50/125. People usually refer 62.5/125 as the OM1 MMF,
+ common type 50/125 MMF as OM2, OM3 is also 50/125, but it is different from OM2 because it support 10Gig data transmission.
+ The OM3 50/125 fiber optic cable is also called laser optimized fiber cable.
+ Both OM1 and OM2 multimode cables use the orange color jacket (standard practice for commonly used indoor multimode),
+ OM3 use a special color, which is called Aqua."
+ ::= { sleEthernetSFPEntry 16 }
+
+
+ sleEthernetSfpTransceiverDetailTypeStr OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleEthernetSFPEntry 17 }
+
+
+ sleEthernetSfpTransceiverLengthStr OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleEthernetSFPEntry 18 }
+
+
+ sleEthernetSfpWaveLengthStr OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleEthernetSFPEntry 19 }
+
+
+ sleEthernetSfpConnectorType OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleEthernetSFPEntry 20 }
+
+
+ sleEthernetSfpDdmState OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ disable(0),
+ enable(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The DDM state"
+ ::= { sleEthernetSFPEntry 21 }
+
+
+ sleEthernetSfpNegoState OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ off(0),
+ on(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The Nego state"
+ ::= { sleEthernetSFPEntry 22 }
+
+
+ sleEthernetSFPControl OBJECT IDENTIFIER ::= { sleEthernetPort 6 }
+
+
+ sleEthernetSFPControlRequest OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ setSFPRemoteReset(1),
+ setSFPDdmState(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleEthernetSFPControl 1 }
+
+
+ sleEthernetSFPControlStatus OBJECT-TYPE
+ SYNTAX SleControlStatusType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleEthernetSFPControl 2 }
+
+
+ sleEthernetSFPControlTimer OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleEthernetSFPControl 3 }
+
+
+ sleEthernetSFPControlTimeStamp OBJECT-TYPE
+ SYNTAX TimeTicks
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleEthernetSFPControl 4 }
+
+
+ sleEthernetSFPControlReqResult OBJECT-TYPE
+ SYNTAX SleControlRequestResultType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleEthernetSFPControl 5 }
+
+
+ sleEthernetSFPControlIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleEthernetSFPControl 6 }
+
+
+ sleEthernetSfpControlDdmState OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ disable(0),
+ enable(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleEthernetSFPControl 7 }
+
+
+ sleEthernetSFPNotification OBJECT IDENTIFIER ::= { sleEthernetPort 7 }
+
+
+ sleEthernetSFPRemoteReset NOTIFICATION-TYPE
+ OBJECTS { sleEthernetSFPControlRequest, sleEthernetSFPControlTimeStamp, sleEthernetSFPControlReqResult, sleEthernetSFPControlIndex }
+ STATUS current
+ DESCRIPTION
+ "setSFPRemoteReset"
+ ::= { sleEthernetSFPNotification 1 }
+
+
+ sleEthernetSFPDdmState NOTIFICATION-TYPE
+ OBJECTS { sleEthernetSFPControlRequest, sleEthernetSFPControlTimeStamp, sleEthernetSFPControlReqResult, sleEthernetSFPControlIndex, sleEthernetSfpControlDdmState
+ }
+ STATUS current
+ DESCRIPTION
+ "setSFPDdmState"
+ ::= { sleEthernetSFPNotification 2 }
+
+
+ sleEthernetSFPThresholdTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SleEthernetSFPThresholdEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleEthernetPort 8 }
+
+
+ sleEthernetSFPThresholdEntry OBJECT-TYPE
+ SYNTAX SleEthernetSFPThresholdEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Description."
+ INDEX { sleEthernetSFPThresholdIfIndex, sleEthernetSFPThresholdType }
+ ::= { sleEthernetSFPThresholdTable 1 }
+
+
+ SleEthernetSFPThresholdEntry ::=
+ SEQUENCE {
+ sleEthernetSFPThresholdIfIndex
+ Integer32,
+ sleEthernetSFPThresholdType
+ INTEGER,
+ sleEthernetSFPThresholdSfpLow
+ OCTET STRING,
+ sleEthernetSFPThresholdSfpHigh
+ OCTET STRING,
+ sleEthernetSFPThresholdSystemLow
+ OCTET STRING,
+ sleEthernetSFPThresholdSystemHigh
+ OCTET STRING
+ }
+
+ sleEthernetSFPThresholdIfIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The index of the interface"
+ ::= { sleEthernetSFPThresholdEntry 1 }
+
+
+ sleEthernetSFPThresholdType OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ temperWarning(1),
+ temperAlarm(2),
+ voltageWarning(3),
+ voltageAlarm(4),
+ txbiasWarning(5),
+ txbiasAlarm(6),
+ txpowerWarning(7),
+ txpowerAlarm(8),
+ rxpowerWarning(9),
+ rxpowerAlarm(10)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The Type of Threshold"
+ ::= { sleEthernetSFPThresholdEntry 2 }
+
+
+ sleEthernetSFPThresholdSfpLow OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The Threshold Low Value of Sfp"
+ ::= { sleEthernetSFPThresholdEntry 3 }
+
+
+ sleEthernetSFPThresholdSfpHigh OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The Threshold High Value of Sfp"
+ ::= { sleEthernetSFPThresholdEntry 4 }
+
+
+ sleEthernetSFPThresholdSystemLow OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The Threshold Low Value of System"
+ ::= { sleEthernetSFPThresholdEntry 5 }
+
+
+ sleEthernetSFPThresholdSystemHigh OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The Threshold High Value of System"
+ ::= { sleEthernetSFPThresholdEntry 6 }
+
+
+ sleEthernetSFPThresholdControl OBJECT IDENTIFIER ::= { sleEthernetPort 9 }
+
+
+ sleEthernetSFPThresholdControlRequest OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ setSfpThresholdModule(1),
+ setSystemThresholdModule(2),
+ delThresholdModule(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleEthernetSFPThresholdControl 1 }
+
+
+ sleEthernetSFPThresholdControlStatus OBJECT-TYPE
+ SYNTAX SleControlStatusType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleEthernetSFPThresholdControl 2 }
+
+
+ sleEthernetSFPThresholdControlTimer OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleEthernetSFPThresholdControl 3 }
+
+
+ sleEthernetSFPThresholdControlTimeStamp OBJECT-TYPE
+ SYNTAX TimeTicks
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleEthernetSFPThresholdControl 4 }
+
+
+ sleEthernetSFPThresholdControlReqResult OBJECT-TYPE
+ SYNTAX SleControlRequestResultType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleEthernetSFPThresholdControl 5 }
+
+
+ sleEthernetSFPThresholdControlIfIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The index of the interface"
+ ::= { sleEthernetSFPThresholdControl 6 }
+
+
+ sleEthernetSFPThresholdControlType OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ temperWarning(1),
+ temperAlarm(2),
+ voltageWarning(3),
+ voltageAlarm(4),
+ txbiasWarning(5),
+ txbiasAlarm(6),
+ txpowerWarning(7),
+ txpowerAlarm(8),
+ rxpowerWarning(9),
+ rxpowerAlarm(10)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The Type of Threshold"
+ ::= { sleEthernetSFPThresholdControl 7 }
+
+
+ sleEthernetSFPThresholdControlSfpLow OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The Threshold Low Value of Sfp"
+ ::= { sleEthernetSFPThresholdControl 8 }
+
+
+ sleEthernetSFPThresholdControlSfpHigh OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The Threshold High Value of Sfp"
+ ::= { sleEthernetSFPThresholdControl 9 }
+
+
+ sleEthernetSFPThresholdControlSystemLow OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The Threshold Low Value of System"
+ ::= { sleEthernetSFPThresholdControl 10 }
+
+
+ sleEthernetSFPThresholdControlSystemHigh OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The Threshold High Value of System"
+ ::= { sleEthernetSFPThresholdControl 11 }
+
+
+ sleEthernetSFPThresholdNotification OBJECT IDENTIFIER ::= { sleEthernetPort 10 }
+
+
+ sleEthernetSFPThresholdSfpChanged NOTIFICATION-TYPE
+ OBJECTS { sleEthernetSFPThresholdControlRequest, sleEthernetSFPThresholdControlTimeStamp, sleEthernetSFPThresholdControlReqResult, sleEthernetSFPThresholdControlIfIndex, sleEthernetSFPThresholdControlType,
+ sleEthernetSFPThresholdControlSfpLow, sleEthernetSFPThresholdControlSfpHigh }
+ STATUS current
+ DESCRIPTION
+ "setSfpThresholdModule "
+ ::= { sleEthernetSFPThresholdNotification 1 }
+
+
+ sleEthernetSFPThresholdSystemChanged NOTIFICATION-TYPE
+ OBJECTS { sleEthernetSFPThresholdControlRequest, sleEthernetSFPThresholdControlTimeStamp, sleEthernetSFPThresholdControlReqResult, sleEthernetSFPThresholdControlIfIndex, sleEthernetSFPThresholdControlType,
+ sleEthernetSFPThresholdControlSystemLow, sleEthernetSFPThresholdControlSystemHigh }
+ STATUS current
+ DESCRIPTION
+ "setSystemThresholdModule "
+ ::= { sleEthernetSFPThresholdNotification 2 }
+
+
+ sleEthernetSFPThresholdDestroyed NOTIFICATION-TYPE
+ OBJECTS { sleEthernetSFPThresholdControlRequest, sleEthernetSFPThresholdControlTimeStamp, sleEthernetSFPThresholdControlReqResult, sleEthernetSFPThresholdControlIfIndex, sleEthernetSFPThresholdControlType
+ }
+ STATUS current
+ DESCRIPTION
+ "delThresholdModule "
+ ::= { sleEthernetSFPThresholdNotification 3 }
+
+
+ slePower OBJECT IDENTIFIER ::= { sleDevice 3 }
+
+
+ slePowerTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SlePowerEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { slePower 1 }
+
+
+ slePowerEntry OBJECT-TYPE
+ SYNTAX SlePowerEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Description."
+ INDEX { slePowerIndex }
+ ::= { slePowerTable 1 }
+
+
+ SlePowerEntry ::=
+ SEQUENCE {
+ slePowerIndex
+ INTEGER,
+ slePowerPhyIndex
+ Integer32,
+ slePowerState
+ INTEGER,
+ slePowerType
+ INTEGER,
+ slePowerPSUType
+ INTEGER
+ }
+
+ slePowerIndex OBJECT-TYPE
+ SYNTAX INTEGER (1..255)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A unique value, greater than zero, for each module. It is recommended that values are assigned contiguously starting from 1. The value for each interface sub-layer must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization."
+ ::= { slePowerEntry 1 }
+
+
+ slePowerPhyIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "entPhysicalIndex of Power Modules (0: Internal, -1: uninstalled)"
+ ::= { slePowerEntry 2 }
+
+
+ slePowerState OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ failure(0),
+ ok(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Power status information."
+ ::= { slePowerEntry 3 }
+
+
+ slePowerType OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ ac(1),
+ dc(2),
+ unknown(3),
+ psu(4)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Power type information."
+ ::= { slePowerEntry 4 }
+
+
+ slePowerPSUType OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ psuA(1),
+ psuS(2),
+ unknown(255)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The type of Power Supply Unit.(DC)"
+ ::= { slePowerEntry 5 }
+
+
+ sleFanModule OBJECT IDENTIFIER ::= { sleDevice 4 }
+
+
+ sleFanModuleTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SleFanModuleEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleFanModule 1 }
+
+
+ sleFanModuleEntry OBJECT-TYPE
+ SYNTAX SleFanModuleEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Description."
+ INDEX { sleFanModuleIndex }
+ ::= { sleFanModuleTable 1 }
+
+
+ SleFanModuleEntry ::=
+ SEQUENCE {
+ sleFanModuleIndex
+ INTEGER,
+ sleFanModulePhyIndex
+ Integer32,
+ sleFanModuleUnitNum
+ Integer32,
+ sleFanModuleAdminState
+ INTEGER,
+ sleFanModuleSpeedThreshold
+ Integer32
+ }
+
+ sleFanModuleIndex OBJECT-TYPE
+ SYNTAX INTEGER (1..255)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A unique value, greater than zero, for each module. It is recommended that values are assigned contiguously starting from 1."
+ ::= { sleFanModuleEntry 1 }
+
+
+ sleFanModulePhyIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "entPhysicalIndex of FAN Modules. (0: Internal, -1: uninstalled)"
+ ::= { sleFanModuleEntry 2 }
+
+
+ sleFanModuleUnitNum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of unit in FAN module"
+ ::= { sleFanModuleEntry 3 }
+
+
+ sleFanModuleAdminState OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ off(0),
+ on(1),
+ auto(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An administrative state of FAN module"
+ ::= { sleFanModuleEntry 4 }
+
+
+ sleFanModuleSpeedThreshold OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Fan-speed threshold"
+ ::= { sleFanModuleEntry 5 }
+
+
+ sleFanModuleControl OBJECT IDENTIFIER ::= { sleFanModule 2 }
+
+
+ sleFanModuleControlRequest OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ setFanAdminState(1),
+ setFanSpeedThreshold(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "set an administrative state of FAN module"
+ ::= { sleFanModuleControl 1 }
+
+
+ sleFanModuleControlStatus OBJECT-TYPE
+ SYNTAX SleControlStatusType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleFanModuleControl 2 }
+
+
+ sleFanModuleControlTimer OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleFanModuleControl 3 }
+
+
+ sleFanModuleControlTimeStamp OBJECT-TYPE
+ SYNTAX TimeTicks
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleFanModuleControl 4 }
+
+
+ sleFanModuleControlReqResult OBJECT-TYPE
+ SYNTAX SleControlRequestResultType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleFanModuleControl 5 }
+
+
+ sleFanModuleControlIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleFanModuleControl 6 }
+
+
+ sleFanModuleControlAdminState OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ off(0),
+ on(1),
+ auto(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "An administrative state of FAN module"
+ ::= { sleFanModuleControl 7 }
+
+
+ sleFanModuleControlSpeedThreshold OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fan-speed threshold"
+ ::= { sleFanModuleControl 8 }
+
+
+ sleFanModuleNotification OBJECT IDENTIFIER ::= { sleFanModule 3 }
+
+
+ sleFanAdminStateChanged NOTIFICATION-TYPE
+ OBJECTS { sleFanModuleAdminState, sleFanModuleControlRequest, sleFanModuleControlTimeStamp, sleFanModuleControlReqResult }
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleFanModuleNotification 1 }
+
+
+ sleFanSpeedThresholdChanged NOTIFICATION-TYPE
+ OBJECTS { sleFanModuleControlRequest, sleFanModuleControlTimeStamp, sleFanModuleControlReqResult, sleFanModuleControlIndex, sleFanModuleControlSpeedThreshold
+ }
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleFanModuleNotification 2 }
+
+
+ sleFanUnit OBJECT IDENTIFIER ::= { sleDevice 5 }
+
+
+ sleFanUnitTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SleFanUnitEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleFanUnit 1 }
+
+
+ sleFanUnitEntry OBJECT-TYPE
+ SYNTAX SleFanUnitEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Description."
+ INDEX { sleFanModuleIndex, sleFanUnitIndex }
+ ::= { sleFanUnitTable 1 }
+
+
+ SleFanUnitEntry ::=
+ SEQUENCE {
+ sleFanUnitIndex
+ INTEGER,
+ sleFanUnitOperState
+ INTEGER,
+ sleFanUnitSpeed
+ Integer32
+ }
+
+ sleFanUnitIndex OBJECT-TYPE
+ SYNTAX INTEGER (1..255)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A unique number in FAN module"
+ ::= { sleFanUnitEntry 1 }
+
+
+ sleFanUnitOperState OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ failure(0),
+ ok(1),
+ stop(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An operational state of FAN unit"
+ ::= { sleFanUnitEntry 2 }
+
+
+ sleFanUnitSpeed OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Speed of FAN unit"
+ ::= { sleFanUnitEntry 3 }
+
+
+ sleTemperature OBJECT IDENTIFIER ::= { sleDevice 6 }
+
+
+ sleTemperatureTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SleTemperatureEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleTemperature 1 }
+
+
+ sleTemperatureEntry OBJECT-TYPE
+ SYNTAX SleTemperatureEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Description."
+ INDEX { sleTemperatureIndex }
+ ::= { sleTemperatureTable 1 }
+
+
+ SleTemperatureEntry ::=
+ SEQUENCE {
+ sleTemperatureIndex
+ INTEGER,
+ sleTemperatureState
+ INTEGER,
+ sleTemperatureValue
+ Integer32,
+ sleTemperatureHighThreshold
+ Integer32,
+ sleTemperatureLowThreshold
+ Integer32,
+ sleTemperatureWarnHighThreshold
+ Integer32,
+ sleTemperatureWarnLowThreshold
+ Integer32,
+ sleTemperatureWarnDuration
+ Integer32,
+ sleTemperatureAlarmHighThreshold
+ Integer32,
+ sleTemperatureAlarmLowThreshold
+ Integer32,
+ sleTemperatureAlarmDuration
+ Integer32
+ }
+
+ sleTemperatureIndex OBJECT-TYPE
+ SYNTAX INTEGER (1..255)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A unique value, greater than zero, for each module. It is recommended that values are assigned contiguously starting from 1."
+ ::= { sleTemperatureEntry 1 }
+
+
+ sleTemperatureState OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ failure(0),
+ ok(1),
+ others(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Temperature status information"
+ ::= { sleTemperatureEntry 2 }
+
+
+ sleTemperatureValue OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value of temperature sensor. (unit: C)"
+ ::= { sleTemperatureEntry 3 }
+
+
+ sleTemperatureHighThreshold OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The High threshold of temperature."
+ ::= { sleTemperatureEntry 4 }
+
+
+ sleTemperatureLowThreshold OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The Low threshold of temperature."
+ ::= { sleTemperatureEntry 5 }
+
+
+ sleTemperatureWarnHighThreshold OBJECT-TYPE
+ SYNTAX Integer32 (-40..100)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The High threshold of temperature."
+ ::= { sleTemperatureEntry 6 }
+
+
+ sleTemperatureWarnLowThreshold OBJECT-TYPE
+ SYNTAX Integer32 (-40..100)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The Low threshold of temperature."
+ ::= { sleTemperatureEntry 7 }
+
+
+ sleTemperatureWarnDuration OBJECT-TYPE
+ SYNTAX Integer32 (0..300)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Duration-time units by the 5 sec.
+ 0: Clear threshold."
+ ::= { sleTemperatureEntry 8 }
+
+
+ sleTemperatureAlarmHighThreshold OBJECT-TYPE
+ SYNTAX Integer32 (-40..100)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The High threshold of temperature."
+ ::= { sleTemperatureEntry 9 }
+
+
+ sleTemperatureAlarmLowThreshold OBJECT-TYPE
+ SYNTAX Integer32 (-40..100)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The Low threshold of temperature."
+ ::= { sleTemperatureEntry 10 }
+
+
+ sleTemperatureAlarmDuration OBJECT-TYPE
+ SYNTAX Integer32 (0..300)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Duration-time units by the 5 sec.
+ 0: Clear threshold."
+ ::= { sleTemperatureEntry 11 }
+
+
+ sleTemperatureControl OBJECT IDENTIFIER ::= { sleTemperature 2 }
+
+
+ sleTemperatureControlRequest OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ setTempThreshold(1),
+ setTempAlarmThreshold(2),
+ setTempWarnThreshold(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "set an administrative state of FAN module"
+ ::= { sleTemperatureControl 1 }
+
+
+ sleTemperatureControlStatus OBJECT-TYPE
+ SYNTAX SleControlStatusType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleTemperatureControl 2 }
+
+
+ sleTemperatureControlTimer OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleTemperatureControl 3 }
+
+
+ sleTemperatureControlTimeStamp OBJECT-TYPE
+ SYNTAX TimeTicks
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleTemperatureControl 4 }
+
+
+ sleTemperatureControlReqResult OBJECT-TYPE
+ SYNTAX SleControlRequestResultType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleTemperatureControl 5 }
+
+
+ sleTemperatureControlIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The Temperature index"
+ ::= { sleTemperatureControl 6 }
+
+
+ sleTemperatureControlHighThreshold OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The High threshold of temperature."
+ ::= { sleTemperatureControl 7 }
+
+
+ sleTemperatureControlLowThreshold OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The Low threshold of temperature."
+ ::= { sleTemperatureControl 8 }
+
+
+ sleTemperatureControlDuration OBJECT-TYPE
+ SYNTAX Integer32 (0..300)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Duration-time units by the 5 sec.
+ 0: Clear threshold."
+ ::= { sleTemperatureControl 9 }
+
+
+ sleTemperatureNotification OBJECT IDENTIFIER ::= { sleTemperature 3 }
+
+
+ sleTemperatureThresholdChanged NOTIFICATION-TYPE
+ OBJECTS { sleTemperatureControlRequest, sleTemperatureControlTimeStamp, sleTemperatureControlReqResult, sleTemperatureIndex, sleTemperatureWarnHighThreshold,
+ sleTemperatureWarnLowThreshold, sleTemperatureWarnDuration, sleTemperatureAlarmHighThreshold, sleTemperatureAlarmLowThreshold, sleTemperatureLowThreshold,
+ sleTemperatureAlarmDuration, sleTemperatureHighThreshold }
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleTemperatureNotification 1 }
+
+
+ sleBattery OBJECT IDENTIFIER ::= { sleDevice 7 }
+
+
+ sleBatteryTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SleBatteryEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleBattery 1 }
+
+
+ sleBatteryEntry OBJECT-TYPE
+ SYNTAX SleBatteryEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Description."
+ INDEX { sleBatteryIndex }
+ ::= { sleBatteryTable 1 }
+
+
+ SleBatteryEntry ::=
+ SEQUENCE {
+ sleBatteryIndex
+ INTEGER,
+ sleOperationPowerType
+ INTEGER,
+ sleOperationPowerInfo
+ OCTET STRING,
+ slePSUACPowerState
+ INTEGER,
+ slePSUTemperture
+ Integer32,
+ slePSUTempThreshold
+ Integer32,
+ slePSUOutVoltage
+ OCTET STRING,
+ slePSUOverTemp
+ INTEGER,
+ slePSUFirmwareVer
+ Integer32,
+ sleRBUEquipState
+ INTEGER,
+ sleRBUModeStaus
+ OCTET STRING,
+ sleRBUTemperature1
+ Integer32,
+ sleRBUTemperature2
+ Integer32,
+ sleRBUTempLowThreshold
+ Integer32,
+ sleRBUOutVoltage
+ OCTET STRING,
+ sleRBUChargeCurrent
+ Integer32,
+ sleRBURemainCapacity
+ Integer32,
+ sleRBUOverTemp
+ INTEGER,
+ sleBatteryLow
+ INTEGER,
+ sleRBUTempHighThreshold
+ Integer32,
+ sleRBUBTStatus
+ INTEGER,
+ sleRBUBTThreshold
+ Integer32,
+ sleRBURechargeVoltage
+ Integer32,
+ sleBatteryCellStatus
+ INTEGER,
+ sleBPSUACHardwareVer
+ Integer32
+ }
+
+ sleBatteryIndex OBJECT-TYPE
+ SYNTAX INTEGER (1..256)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The index of battery charger."
+ ::= { sleBatteryEntry 1 }
+
+
+ sleOperationPowerType OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ ac(0),
+ rbu(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Power Type."
+ ::= { sleBatteryEntry 2 }
+
+
+ sleOperationPowerInfo OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Operation Power Info."
+ ::= { sleBatteryEntry 3 }
+
+
+ slePSUACPowerState OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ ok(0),
+ fault(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Power State."
+ ::= { sleBatteryEntry 4 }
+
+
+ slePSUTemperture OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Temperture."
+ ::= { sleBatteryEntry 5 }
+
+
+ slePSUTempThreshold OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Temperture Threshold."
+ ::= { sleBatteryEntry 6 }
+
+
+ slePSUOutVoltage OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Voltage."
+ ::= { sleBatteryEntry 7 }
+
+
+ slePSUOverTemp OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ normal(0),
+ over(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleBatteryEntry 8 }
+
+
+ slePSUFirmwareVer OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The firmware version of battery charger for communication to system."
+ ::= { sleBatteryEntry 9 }
+
+
+ sleRBUEquipState OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ equipped(0),
+ empty(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Equipment State."
+ ::= { sleBatteryEntry 10 }
+
+
+ sleRBUModeStaus OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleBatteryEntry 11 }
+
+
+ sleRBUTemperature1 OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleBatteryEntry 12 }
+
+
+ sleRBUTemperature2 OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "."
+ ::= { sleBatteryEntry 13 }
+
+
+ sleRBUTempLowThreshold OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "RBU Low Temperature Threshold."
+ ::= { sleBatteryEntry 14 }
+
+
+ sleRBUOutVoltage OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "RBU Out Voltage."
+ ::= { sleBatteryEntry 15 }
+
+
+ sleRBUChargeCurrent OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Current Charge."
+ ::= { sleBatteryEntry 16 }
+
+
+ sleRBURemainCapacity OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Remain Capacity."
+ ::= { sleBatteryEntry 17 }
+
+
+ sleRBUOverTemp OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ normal(0),
+ over(1),
+ under(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The state of Temperature over."
+ ::= { sleBatteryEntry 18 }
+
+
+ sleBatteryLow OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ normal(0),
+ low(1),
+ notAvailable(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Battery state."
+ ::= { sleBatteryEntry 19 }
+
+
+ sleRBUTempHighThreshold OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "RBU High Temperature Threshold."
+ ::= { sleBatteryEntry 20 }
+
+
+ sleRBUBTStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ enable(1),
+ disable(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleBatteryEntry 21 }
+
+
+ sleRBUBTThreshold OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleBatteryEntry 22 }
+
+
+ sleRBURechargeVoltage OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleBatteryEntry 23 }
+
+
+ sleBatteryCellStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ ok(1),
+ failure(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleBatteryEntry 24 }
+
+
+ sleBPSUACHardwareVer OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleBatteryEntry 25 }
+
+
+ sleBatteryControl OBJECT IDENTIFIER ::= { sleBattery 2 }
+
+
+ sleBatteryControlRequest OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ setBatteryForceCharge(1),
+ setBatteryChargingStart(2),
+ setBatteryForceChargeNonStop(3),
+ setBatteryBootingTimeStatus(4),
+ setBatteryBootingTime(5),
+ setBatteryRechargeVoltage(6),
+ setPsuAcTemperature(7),
+ setBatteryTemperature(8)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleBatteryControl 1 }
+
+
+ sleBatteryControlStatus OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleBatteryControl 2 }
+
+
+ sleBatteryControlTimer OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleBatteryControl 3 }
+
+
+ sleBatteryControlTimeStamp OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleBatteryControl 4 }
+
+
+ sleBatteryControlReqResult OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleBatteryControl 5 }
+
+
+ sleBatteryControlRBUBTStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ enable(1),
+ disable(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleBatteryControl 6 }
+
+
+ sleBatteryControlRBUBTThreshold OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleBatteryControl 7 }
+
+
+ sleBatteryControlRBURechargeVoltage OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleBatteryControl 8 }
+
+
+ sleBatteryControlTemperThresh1 OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleBatteryControl 9 }
+
+
+ sleBatteryControlTemperThresh2 OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleBatteryControl 10 }
+
+
+ sleBatteryNotification OBJECT IDENTIFIER ::= { sleBattery 3 }
+
+
+ sleBatteryForceChargeChanged NOTIFICATION-TYPE
+ OBJECTS { sleBatteryControlRequest, sleBatteryControlTimeStamp, sleBatteryControlReqResult }
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleBatteryNotification 1 }
+
+
+ sleBatteryChargingStartChanged NOTIFICATION-TYPE
+ OBJECTS { sleBatteryControlRequest, sleBatteryControlTimeStamp, sleBatteryControlReqResult }
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleBatteryNotification 2 }
+
+
+ sleBatteryForceChargeNonStopChanged NOTIFICATION-TYPE
+ OBJECTS { sleBatteryControlRequest, sleBatteryControlTimeStamp, sleBatteryControlReqResult }
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleBatteryNotification 3 }
+
+
+ sleBatteryRBUBTStatusChanged NOTIFICATION-TYPE
+ OBJECTS { sleBatteryControlRequest, sleBatteryControlTimeStamp, sleBatteryControlReqResult, sleRBUBTStatus }
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleBatteryNotification 4 }
+
+
+ sleBatteryRBUBTThresholdChanged NOTIFICATION-TYPE
+ OBJECTS { sleBatteryControlRequest, sleBatteryControlTimeStamp, sleBatteryControlReqResult, sleRBUBTThreshold }
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleBatteryNotification 5 }
+
+
+ sleBatteryRBURechargeVoltageChanged NOTIFICATION-TYPE
+ OBJECTS { sleBatteryControlRequest, sleBatteryControlTimeStamp, sleBatteryControlReqResult, sleRBURechargeVoltage }
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleBatteryNotification 6 }
+
+
+ sleBatteryPsuAcTemperThreshChanged NOTIFICATION-TYPE
+ OBJECTS { sleBatteryControlRequest, sleBatteryControlTimeStamp, sleBatteryControlReqResult, slePSUTempThreshold }
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleBatteryNotification 7 }
+
+
+ sleBatteryRBUTemperThreshChanged NOTIFICATION-TYPE
+ OBJECTS { sleBatteryControlRequest, sleBatteryControlTimeStamp, sleBatteryControlReqResult, sleRBUTempLowThreshold, sleRBUTempHighThreshold
+ }
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleBatteryNotification 8 }
+
+
+ sleBatteryBackupTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SleBatteryBackupEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleBattery 4 }
+
+
+ sleBatteryBackupEntry OBJECT-TYPE
+ SYNTAX SleBatteryBackupEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Description."
+ INDEX { sleBatteryBackupFile }
+ ::= { sleBatteryBackupTable 1 }
+
+
+ SleBatteryBackupEntry ::=
+ SEQUENCE {
+ sleBatteryBackupFile
+ OCTET STRING
+ }
+
+ sleBatteryBackupFile OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (1..64))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleBatteryBackupEntry 1 }
+
+
+ sleBatteryBackupControl OBJECT IDENTIFIER ::= { sleBattery 5 }
+
+
+ sleBatteryBackupControlRequest OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ setBatteryBackupProfile(1),
+ setBatteryUpgrade(2),
+ clearBatteryBackupTable(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleBatteryBackupControl 1 }
+
+
+ sleBatteryBackupControlStatus OBJECT-TYPE
+ SYNTAX SleControlStatusType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleBatteryBackupControl 2 }
+
+
+ sleBatteryBackupControlTimer OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleBatteryBackupControl 3 }
+
+
+ sleBatteryBackupControlTimeStamp OBJECT-TYPE
+ SYNTAX TimeTicks
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleBatteryBackupControl 4 }
+
+
+ sleBatteryBackupControlReqResult OBJECT-TYPE
+ SYNTAX SleControlRequestResultType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleBatteryBackupControl 5 }
+
+
+ sleBatteryBackupControlServerIP OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleBatteryBackupControl 6 }
+
+
+ sleBatteryBackupControlUserID OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (1..64))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleBatteryBackupControl 7 }
+
+
+ sleBatteryBackupControlPassword OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (1..64))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleBatteryBackupControl 8 }
+
+
+ sleBatteryBackupControlFlag OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ download(1),
+ upload(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleBatteryBackupControl 9 }
+
+
+ sleBatteryBackupControlLocalFile OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (1..64))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleBatteryBackupControl 10 }
+
+
+ sleBatteryBackupControlRemoteFile OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (1..64))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleBatteryBackupControl 11 }
+
+
+ sleBatterBackupNotification OBJECT IDENTIFIER ::= { sleBattery 6 }
+
+
+ sleBatteryBackupProfileChanged NOTIFICATION-TYPE
+ OBJECTS { sleBatteryBackupControlRequest, sleBatteryBackupControlTimeStamp, sleBatteryBackupControlReqResult, sleBatteryBackupControlServerIP, sleBatteryBackupControlUserID,
+ sleBatteryBackupControlPassword, sleBatteryBackupControlFlag, sleBatteryBackupControlLocalFile, sleBatteryBackupControlRemoteFile }
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleBatterBackupNotification 1 }
+
+
+ sleBatteryBackupUpgraded NOTIFICATION-TYPE
+ OBJECTS { sleBatteryBackupControlRequest, sleBatteryBackupControlTimeStamp, sleBatteryBackupControlReqResult, sleBatteryBackupControlLocalFile }
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleBatterBackupNotification 2 }
+
+
+ sleBatteryBackupTableCleared NOTIFICATION-TYPE
+ OBJECTS { sleBatteryBackupControlRequest, sleBatteryBackupControlTimeStamp, sleBatteryBackupControlReqResult, sleBatteryBackupControlLocalFile }
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleBatterBackupNotification 3 }
+
+
+ sleDoor OBJECT IDENTIFIER ::= { sleDevice 8 }
+
+
+ sleDoorInfo OBJECT IDENTIFIER ::= { sleDoor 1 }
+
+
+ sleDoorStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ close(0),
+ open(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleDoorInfo 1 }
+
+
+ sleCpu OBJECT IDENTIFIER ::= { sleDevice 9 }
+
+
+ sleCpuInfo OBJECT IDENTIFIER ::= { sleCpu 1 }
+
+
+ sleCpuProcessor OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleCpuInfo 1 }
+
+
+ sleCpuModel OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleCpuInfo 2 }
+
+
+ sleCpuRevision OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleCpuInfo 3 }
+
+
+ sleCpuBogomips OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleCpuInfo 4 }
+
+
+ sleCpuManufacturer OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleCpuInfo 5 }
+
+
+ sleCpuClock OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleCpuInfo 6 }
+
+
+ sleCpuBusClock OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleCpuInfo 7 }
+
+
+ sleClockModule OBJECT IDENTIFIER ::= { sleDevice 10 }
+
+
+ sleClockModuleTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SleClockModuleEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleClockModule 1 }
+
+
+ sleClockModuleEntry OBJECT-TYPE
+ SYNTAX SleClockModuleEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Description."
+ INDEX { sleClockModuleIndex }
+ ::= { sleClockModuleTable 1 }
+
+
+ SleClockModuleEntry ::=
+ SEQUENCE {
+ sleClockModuleIndex
+ INTEGER,
+ sleClockModuleBoardId
+ INTEGER,
+ sleClockModuleInstallStatus
+ INTEGER,
+ sleClockModuleInitStatus
+ INTEGER,
+ sleClockModuleOPMode
+ INTEGER
+ }
+
+ sleClockModuleIndex OBJECT-TYPE
+ SYNTAX INTEGER (1..255)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A unique value, greater than zero, for each module. It is recommended that values are assigned contiguously starting from 1."
+ ::= { sleClockModuleEntry 1 }
+
+
+ sleClockModuleBoardId OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ sfuA(1),
+ sfuB(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indication of the board identifier."
+ ::= { sleClockModuleEntry 2 }
+
+
+ sleClockModuleInstallStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ removed(0),
+ installed(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The install status of clock module."
+ ::= { sleClockModuleEntry 3 }
+
+
+ sleClockModuleInitStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ failure(0),
+ ok(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The initialization status of clock module."
+ ::= { sleClockModuleEntry 4 }
+
+
+ sleClockModuleOPMode OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ freerun(1),
+ holdover(2),
+ locked(3),
+ prelocked2(4),
+ prelocked(5),
+ lostphase(6),
+ unknown(255)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The CM operating mode"
+ ::= { sleClockModuleEntry 5 }
+
+
+ sleClockInfo OBJECT IDENTIFIER ::= { sleClockModule 2 }
+
+
+ sleClockInfoInSrcType OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ ntt(1),
+ ntt2(2),
+ e1(3),
+ t1(4),
+ unknown(255)
+ }
+ MAX-ACCESS accessible-for-notify
+ STATUS current
+ DESCRIPTION
+ "The clock input source type."
+ ::= { sleClockInfo 1 }
+
+
+ sleClockInfoInSrcStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ true(1),
+ false(2)
+ }
+ MAX-ACCESS accessible-for-notify
+ STATUS current
+ DESCRIPTION
+ "The input source is Valid or Invalid."
+ ::= { sleClockInfo 2 }
+
+
+ sleClockInfoInSrcAISStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ true(1),
+ false(2)
+ }
+ MAX-ACCESS accessible-for-notify
+ STATUS current
+ DESCRIPTION
+ "The AIS is detected or not detected."
+ ::= { sleClockInfo 3 }
+
+
+ sleClockInfoInSrcLoSStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ true(1),
+ false(2)
+ }
+ MAX-ACCESS accessible-for-notify
+ STATUS current
+ DESCRIPTION
+ "The LoS is detected or not detected"
+ ::= { sleClockInfo 4 }
+
+
+ sleClockInfoInSrcLDSCStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ true(1),
+ false(2)
+ }
+ MAX-ACCESS accessible-for-notify
+ STATUS current
+ DESCRIPTION
+ "The Line Driver Short Circuit is detected or not detected"
+ ::= { sleClockInfo 5 }
+
+
+ sleClockInfoInSrcNtrClockType OBJECT-TYPE
+ SYNTAX BITS
+ {
+ bit64Khz(0),
+ bit8Khz(1),
+ bit04Khz(2)
+ }
+ MAX-ACCESS accessible-for-notify
+ STATUS current
+ DESCRIPTION
+ "The ntr clock is changed."
+ ::= { sleClockInfo 6 }
+
+
+ sleSlot OBJECT IDENTIFIER ::= { sleDevice 11 }
+
+
+ sleSlotSystemInfo OBJECT IDENTIFIER ::= { sleSlot 1 }
+
+
+ sleSlotSystemInfoTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SleSlotSystemInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleSlotSystemInfo 1 }
+
+
+ sleSlotSystemInfoEntry OBJECT-TYPE
+ SYNTAX SleSlotSystemInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Description."
+ INDEX { sleSlotSystemIndex }
+ ::= { sleSlotSystemInfoTable 1 }
+
+
+ SleSlotSystemInfoEntry ::=
+ SEQUENCE {
+ sleSlotSystemIndex
+ Integer32,
+ sleSlotSystemUptime
+ TimeTicks,
+ sleSlotSystemModelName
+ OCTET STRING,
+ sleSlotSystemSerialNumber
+ OCTET STRING,
+ sleSlotSystemHWVersion
+ OCTET STRING,
+ sleSlotSystemBLVersion
+ OCTET STRING,
+ sleSlotSystemSWCompatibility
+ OCTET STRING,
+ sleSlotSystemOSVersion
+ OCTET STRING,
+ sleSlotSystemMacAddress
+ OCTET STRING,
+ sleSlotSystemCPULoadAll
+ OCTET STRING,
+ sleSlotSystemCPULoadInterrupt
+ OCTET STRING,
+ sleSlotSystemMemoryTotal
+ Gauge32,
+ sleSlotSystemMemoryFree
+ Gauge32,
+ sleSlotSystemMemoryShared
+ Gauge32,
+ sleSlotSystemMemoryBuffers
+ Gauge32,
+ sleSlotSystemMemoryCached
+ Gauge32,
+ sleSlotSystemMemorySwapTotal
+ Gauge32,
+ sleSlotSystemMemorySwapFree
+ Gauge32,
+ sleSlotSystemBootReason
+ INTEGER,
+ sleSlotSystemBootTime
+ Gauge32,
+ sleSlotSystemVoltage
+ Gauge32,
+ sleSlotSystemPowerLevelStatus
+ INTEGER,
+ sleSlotSystemInfoLEDStatus
+ BITS,
+ sleSlotSystemInfoPackageVersion
+ OCTET STRING,
+ sleSlotSystemInfoManufacturer
+ OCTET STRING,
+ sleSlotSystemInfoManufactureDate
+ OCTET STRING,
+ sleSlotSystemCPULoadHighThreshold
+ Integer32,
+ sleSlotSystemCPULoadHighThresholdTimer
+ INTEGER,
+ sleSlotSystemCPULoadLowThreshold
+ Integer32,
+ sleSlotSystemCPULoadLowThresholdTimer
+ INTEGER,
+ sleSlotSystemCPULoadCurrent
+ Integer32,
+ sleSlotSystemCPUOverallStatus
+ INTEGER,
+ sleSlotSystemTemperOverallStatus
+ INTEGER
+ }
+
+ sleSlotSystemIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..8)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The system slot index."
+ ::= { sleSlotSystemInfoEntry 1 }
+
+
+ sleSlotSystemUptime OBJECT-TYPE
+ SYNTAX TimeTicks
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The time since the network management portion of the system was last re-initialized."
+ ::= { sleSlotSystemInfoEntry 2 }
+
+
+ sleSlotSystemModelName OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The model name."
+ ::= { sleSlotSystemInfoEntry 3 }
+
+
+ sleSlotSystemSerialNumber OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The serial number "
+ ::= { sleSlotSystemInfoEntry 4 }
+
+
+ sleSlotSystemHWVersion OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The H/W version."
+ ::= { sleSlotSystemInfoEntry 5 }
+
+
+ sleSlotSystemBLVersion OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The boot loader¡¯s S/W version."
+ ::= { sleSlotSystemInfoEntry 6 }
+
+
+ sleSlotSystemSWCompatibility OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The system compatibility."
+ ::= { sleSlotSystemInfoEntry 7 }
+
+
+ sleSlotSystemOSVersion OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The version information of current os."
+ ::= { sleSlotSystemInfoEntry 8 }
+
+
+ sleSlotSystemMacAddress OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The system¡¯s MAC address."
+ ::= { sleSlotSystemInfoEntry 9 }
+
+
+ sleSlotSystemCPULoadAll OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The CPU all load for 5/60/600 second. (unit: 0.01%)"
+ ::= { sleSlotSystemInfoEntry 10 }
+
+
+ sleSlotSystemCPULoadInterrupt OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The CPU interrupt load for 5/60/600 second. (unit: 0.01%)"
+ ::= { sleSlotSystemInfoEntry 11 }
+
+
+ sleSlotSystemMemoryTotal OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total memory size (unit: kb)"
+ ::= { sleSlotSystemInfoEntry 12 }
+
+
+ sleSlotSystemMemoryFree OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The freed memory size (unit: kb)"
+ ::= { sleSlotSystemInfoEntry 13 }
+
+
+ sleSlotSystemMemoryShared OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The shared memory size (unit: kb)"
+ ::= { sleSlotSystemInfoEntry 14 }
+
+
+ sleSlotSystemMemoryBuffers OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The buffer size (unit: kb)"
+ ::= { sleSlotSystemInfoEntry 15 }
+
+
+ sleSlotSystemMemoryCached OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The cached memory size (unit: kb)"
+ ::= { sleSlotSystemInfoEntry 16 }
+
+
+ sleSlotSystemMemorySwapTotal OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total swap memory size (unit: kb)"
+ ::= { sleSlotSystemInfoEntry 17 }
+
+
+ sleSlotSystemMemorySwapFree OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The freed swap memory size (unit: kb)"
+ ::= { sleSlotSystemInfoEntry 18 }
+
+
+ sleSlotSystemBootReason OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ powerBoot(1),
+ powerBootByLocal(2),
+ hwResetBySW(3),
+ hardWdogByLocal(4),
+ hwRebootByMate(5),
+ hwRebootBySwitchover(6),
+ swReboot(10),
+ swRebootByLocal(11),
+ swRebootBySFU(12),
+ swRebootBySwitchover(13),
+ swRebootByPanic(14),
+ watchdog(20),
+ watchdogByLocal(21),
+ swWatchdog(30),
+ swWatchdogByCpuOver(31),
+ swWatchdogByMemoryLow(32),
+ error(255)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The system slot boot reason."
+ ::= { sleSlotSystemInfoEntry 19 }
+
+
+ sleSlotSystemBootTime OBJECT-TYPE
+ SYNTAX Gauge32
+ UNITS "1 second"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The system slot boot time.
+ The time since the Epoch (00:00:00 UTC, January 1, 1970), measured in seconds.
+ "
+ ::= { sleSlotSystemInfoEntry 20 }
+
+
+ sleSlotSystemVoltage OBJECT-TYPE
+ SYNTAX Gauge32
+ UNITS "0.1 v"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The system slot voltage."
+ ::= { sleSlotSystemInfoEntry 21 }
+
+
+ sleSlotSystemPowerLevelStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ good(1),
+ bad(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "PCB Power level status."
+ ::= { sleSlotSystemInfoEntry 22 }
+
+
+ sleSlotSystemInfoLEDStatus OBJECT-TYPE
+ SYNTAX BITS
+ {
+ pwr(0),
+ run(1),
+ critical(2),
+ major(3),
+ minor(4),
+ error(5)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The LED status of each slot."
+ ::= { sleSlotSystemInfoEntry 23 }
+
+
+ sleSlotSystemInfoPackageVersion OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The applied package revision."
+ ::= { sleSlotSystemInfoEntry 24 }
+
+
+ sleSlotSystemInfoManufacturer OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Ths manufacturer name and country."
+ ::= { sleSlotSystemInfoEntry 25 }
+
+
+ sleSlotSystemInfoManufactureDate OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Ths manufacture date."
+ ::= { sleSlotSystemInfoEntry 26 }
+
+
+ sleSlotSystemCPULoadHighThreshold OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The high threshold of CPU load (70:default)"
+ ::= { sleSlotSystemInfoEntry 27 }
+
+
+ sleSlotSystemCPULoadHighThresholdTimer OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ timerInverval5(1),
+ timerInverval60(2),
+ timerInverval600(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The high threshold timer of CPU load (sec) (60:default)"
+ ::= { sleSlotSystemInfoEntry 28 }
+
+
+ sleSlotSystemCPULoadLowThreshold OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The low threshold of CPU load (30:default)"
+ ::= { sleSlotSystemInfoEntry 29 }
+
+
+ sleSlotSystemCPULoadLowThresholdTimer OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ timerInverval5(1),
+ timerInverval60(2),
+ timerInverval600(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The low threshold timer of CPU load (sec) (60:default)"
+ ::= { sleSlotSystemInfoEntry 30 }
+
+
+ sleSlotSystemCPULoadCurrent OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The CPU load currnet value (only used for trap)"
+ ::= { sleSlotSystemInfoEntry 31 }
+
+
+ sleSlotSystemCPUOverallStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ good(1),
+ bad(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The CPU Overall status for SFU & IU"
+ ::= { sleSlotSystemInfoEntry 32 }
+
+
+ sleSlotSystemTemperOverallStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ good(1),
+ bad(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The Temperature Overall status for SFU & IU"
+ ::= { sleSlotSystemInfoEntry 33 }
+
+
+ sleSlotSystemControl OBJECT IDENTIFIER ::= { sleSlotSystemInfo 2 }
+
+
+ sleSlotSystemControlRequest OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ setSlotRestart(1),
+ setSlotCpuloadThreshold(2),
+ delSlotCpuloadThreshold(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The request of a user command"
+ ::= { sleSlotSystemControl 1 }
+
+
+ sleSlotSystemControlStatus OBJECT-TYPE
+ SYNTAX SleControlStatusType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The status of user command"
+ ::= { sleSlotSystemControl 2 }
+
+
+ sleSlotSystemControlTimer OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The maximum time for the manager for a long running user command"
+ ::= { sleSlotSystemControl 3 }
+
+
+ sleSlotSystemControlTimeStamp OBJECT-TYPE
+ SYNTAX TimeTicks
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The time stamp of the last command(end of command)"
+ ::= { sleSlotSystemControl 4 }
+
+
+ sleSlotSystemControlReqResult OBJECT-TYPE
+ SYNTAX SleControlRequestResultType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The result of the last user command"
+ ::= { sleSlotSystemControl 5 }
+
+
+ sleSlotSystemControlSlotIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The system slot index."
+ ::= { sleSlotSystemControl 6 }
+
+
+ sleSlotSystemControlCPULoadHighThreshold OBJECT-TYPE
+ SYNTAX Integer32 (21..100)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The high threshold of CPU load (70:default)"
+ ::= { sleSlotSystemControl 7 }
+
+
+ sleSlotSystemControlCPULoadHighThresholdTimer OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ timerInverval5(1),
+ timerInverval60(2),
+ timerInverval600(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The high threshold timer of CPU load (sec) (60:default)"
+ ::= { sleSlotSystemControl 8 }
+
+
+ sleSlotSystemControlCPULoadLowThreshold OBJECT-TYPE
+ SYNTAX Integer32 (20..100)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The low threshold of CPU load (30:default)"
+ ::= { sleSlotSystemControl 9 }
+
+
+ sleSlotSystemControlCPULoadLowThresholdTimer OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ timerInverval5(1),
+ timerInverval60(2),
+ timerInverval600(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The low threshold timer of CPU load (sec) (60:default)"
+ ::= { sleSlotSystemControl 10 }
+
+
+ sleSlotSystemNotification OBJECT IDENTIFIER ::= { sleSlotSystemInfo 3 }
+
+
+ sleSlotSystemRestart NOTIFICATION-TYPE
+ OBJECTS { sleSlotSystemControlRequest, sleSlotSystemControlTimeStamp, sleSlotSystemControlReqResult, sleSlotSystemControlSlotIndex }
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleSlotSystemNotification 1 }
+
+
+ sleSlotSystemCPULoadChagned NOTIFICATION-TYPE
+ OBJECTS { sleSlotSystemControlRequest, sleSlotSystemControlTimeStamp, sleSlotSystemControlReqResult, sleSlotSystemControlSlotIndex, sleSlotSystemControlCPULoadHighThreshold,
+ sleSlotSystemControlCPULoadHighThresholdTimer, sleSlotSystemControlCPULoadLowThreshold, sleSlotSystemControlCPULoadLowThresholdTimer }
+ STATUS current
+ DESCRIPTION
+ "setSlotCpuloadThreshold"
+ ::= { sleSlotSystemNotification 2 }
+
+
+ sleSlotSystemCPULoadDeleted NOTIFICATION-TYPE
+ OBJECTS { sleSlotSystemControlRequest, sleSlotSystemControlTimeStamp, sleSlotSystemControlReqResult, sleSlotSystemControlSlotIndex }
+ STATUS current
+ DESCRIPTION
+ "delSlotCpuloadThreshold"
+ ::= { sleSlotSystemNotification 3 }
+
+
+ sleSlotStatusInfo OBJECT IDENTIFIER ::= { sleSlot 2 }
+
+
+ sleSlotStatusInfoTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SleSlotStatusInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleSlotStatusInfo 1 }
+
+
+ sleSlotStatusInfoEntry OBJECT-TYPE
+ SYNTAX SleSlotStatusInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Description."
+ INDEX { sleSlotSystemIndex }
+ ::= { sleSlotStatusInfoTable 1 }
+
+
+ SleSlotStatusInfoEntry ::=
+ SEQUENCE {
+ sleSlotStatusPlan
+ INTEGER,
+ sleSlotStatusPlanCardType
+ INTEGER,
+ sleSlotStatusCurrentInstall
+ INTEGER,
+ sleSlotStatusCurrentInstallCardType
+ INTEGER,
+ sleSlotStatusCardOperation
+ INTEGER,
+ sleSlotStatusLock
+ INTEGER,
+ sleSlotStatusUpgradeMode
+ INTEGER,
+ sleSlotStatusActionEvent
+ INTEGER,
+ sleSlotStatusState
+ INTEGER,
+ sleSlotStatusPower
+ INTEGER,
+ sleSlotStatusSerialNumber
+ OCTET STRING,
+ sleSlotStatusHealthState
+ INTEGER,
+ sleslotStatusOverallState
+ INTEGER,
+ sleslotStatusSyncState
+ INTEGER
+ }
+
+ sleSlotStatusPlan OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ notPlanned(1),
+ planned(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Planning status of slot."
+ ::= { sleSlotStatusInfoEntry 1 }
+
+
+ sleSlotStatusPlanCardType OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ unknown(1),
+ siuGE12(2),
+ siuEPON12(3),
+ siuGPON4(4),
+ niuGE12(5),
+ sfu(6),
+ v5548gGE12(7),
+ siuGPON4r(8),
+ niuGE8(9),
+ siuGE4(10),
+ niu10GPlus(11),
+ iu10GE(12),
+ iuGE6(13),
+ iuGE4(14),
+ siuTDM(15),
+ siuGE24(16),
+ siuFE48(17),
+ niu10GE2(18),
+ siu10GE48(19),
+ siuGE10(20),
+ niu10Ge2Plus(21),
+ iuGT4(22),
+ iuGT6(23),
+ iuTDM6(24),
+ siuGE6(25),
+ siuGE8(26),
+ siuGT6(27),
+ niuGE2(28),
+ niuGE4(29),
+ iuGEPON4(30),
+ iu10GE8(31),
+ iuGEPON8(32),
+ iu10GEPON8(33),
+ iuGE8(34),
+ siu10GEPON8(35),
+ niu10GE4(36),
+ sfu10GE4(37),
+ siuGPON16(38),
+ iu10GE4(39),
+ siuGT24(40),
+ iu10GE2(41),
+ cwdm(42),
+ iuGT8(43)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Planning card type status of slot."
+ ::= { sleSlotStatusInfoEntry 2 }
+
+
+ sleSlotStatusCurrentInstall OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ notInstalled(1),
+ installed(2),
+ failed(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Currently installation status of slot."
+ ::= { sleSlotStatusInfoEntry 3 }
+
+
+ sleSlotStatusCurrentInstallCardType OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ unknown(1),
+ siuGE12(2),
+ siuEPON12(3),
+ siuGPON4(4),
+ niuGE12(5),
+ sfu(6),
+ v5548gGE12(7),
+ siuGPON4r(8),
+ niuGE8(9),
+ siuGE4(10),
+ niu10GPlus(11),
+ iuGE10(12),
+ iuGE6(13),
+ iuGE4(14),
+ siuTDM(15),
+ siuGE24(16),
+ siuFE48(17),
+ niu10GE2(18),
+ siu10GE48(19),
+ siuGE10(20),
+ niu10Ge2Plus(21),
+ iuGT4(22),
+ iuGT6(23),
+ iuTDM6(24),
+ siuGE6(25),
+ siuGE8(26),
+ siuGT6(27),
+ niuGE2(28),
+ niuGE4(29),
+ iuGEPON4(30),
+ iu10GE8(31),
+ iuGEPON8(32),
+ iu10GEPON8(33),
+ iuGE8(34),
+ siu10GEPON8(35),
+ niu10GE4(36),
+ sfu10GE4(37),
+ siuGPON16(38),
+ iu10GE4(39),
+ siuGT24(40),
+ iu10GE2(41),
+ cwdm(42),
+ iuGT8(43)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Currently installation card type status of slot."
+ ::= { sleSlotStatusInfoEntry 4 }
+
+
+ sleSlotStatusCardOperation OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ disable(1),
+ init(2),
+ enable(3),
+ enableActive(4),
+ enableStandby(5)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Currently operation status of slot."
+ ::= { sleSlotStatusInfoEntry 5 }
+
+
+ sleSlotStatusLock OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ unlocked(1),
+ locked(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Lock status of slot."
+ ::= { sleSlotStatusInfoEntry 6 }
+
+
+ sleSlotStatusUpgradeMode OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ manual(1),
+ auto(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Upgrade mode status of slot."
+ ::= { sleSlotStatusInfoEntry 7 }
+
+
+ sleSlotStatusActionEvent OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ uninstallAction(1),
+ installAction(2),
+ noPlanningAction(3),
+ planningAction(4),
+ lockAction(5),
+ unlockAction(6),
+ matchedEvent(7),
+ unMatchedEvent(8),
+ bootEndEvent(9),
+ configEndEvent(10),
+ configFailEvent(11)
+ }
+ MAX-ACCESS accessible-for-notify
+ STATUS current
+ DESCRIPTION
+ "Event of slot. (accessible-for-notify)"
+ ::= { sleSlotStatusInfoEntry 8 }
+
+
+ sleSlotStatusState OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ default(1),
+ planningWait(2),
+ installWait(3),
+ operationReady(4),
+ actionBootReady(5),
+ actionConfig(6),
+ actionEnableReady(7),
+ actionEnable(8),
+ actionEnableLock(9),
+ actionDisable(10)
+ }
+ MAX-ACCESS accessible-for-notify
+ STATUS current
+ DESCRIPTION
+ "Status of slot. (accessible-for-notify)"
+ ::= { sleSlotStatusInfoEntry 9 }
+
+
+ sleSlotStatusPower OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ up(1),
+ down(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Currently power status of slot."
+ ::= { sleSlotStatusInfoEntry 10 }
+
+
+ sleSlotStatusSerialNumber OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The serial number"
+ ::= { sleSlotStatusInfoEntry 11 }
+
+
+ sleSlotStatusHealthState OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ well(0),
+ warning(1),
+ timeout(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The slot health status"
+ ::= { sleSlotStatusInfoEntry 12 }
+
+
+ sleslotStatusOverallState OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ good(0),
+ bad(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The slot overrall status"
+ ::= { sleSlotStatusInfoEntry 13 }
+
+
+ sleslotStatusSyncState OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ none(0),
+ disable(1),
+ process(2),
+ done(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The slot sync status"
+ ::= { sleSlotStatusInfoEntry 14 }
+
+
+ sleSlotStatusControl OBJECT IDENTIFIER ::= { sleSlotStatusInfo 2 }
+
+
+ sleSlotStatusControlRequest OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ setSlotLock(1),
+ setSlotUnlock(2),
+ setSlotPlanning(3),
+ setSlotNoplanning(4),
+ setSlotUpgradeMode(5),
+ setSlotPowerUp(6),
+ setSlotPowerDown(7),
+ setSlotPowerReset(8)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The request of a user command"
+ ::= { sleSlotStatusControl 1 }
+
+
+ sleSlotStatusControlStatus OBJECT-TYPE
+ SYNTAX SleControlStatusType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The status of user command"
+ ::= { sleSlotStatusControl 2 }
+
+
+ sleSlotStatusControlTimer OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The maximum time for the manager for a long running user command"
+ ::= { sleSlotStatusControl 3 }
+
+
+ sleSlotStatusControlTimeStamp OBJECT-TYPE
+ SYNTAX TimeTicks
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The time stamp of the last command(end of command)"
+ ::= { sleSlotStatusControl 4 }
+
+
+ sleSlotStatusControlReqResult OBJECT-TYPE
+ SYNTAX SleControlRequestResultType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The result of the last user command"
+ ::= { sleSlotStatusControl 5 }
+
+
+ sleSlotStatusControlSlotIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The system slot index.
+ 255 is means all slot."
+ ::= { sleSlotStatusControl 6 }
+
+
+ sleSlotStatusControlPlanCardType OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ unknown(1),
+ siuGE12(2),
+ siuEPON12(3),
+ siuGPON4(4),
+ niuGE12(5),
+ sfu(6),
+ v5548gGE12(7),
+ siuGPON4r(8),
+ niuGE8(9),
+ siuGE4(10),
+ niu10GPlus(11),
+ iuGE10(12),
+ iuGE6(13),
+ iuGE4(14),
+ siuTDM(15),
+ siuGE24(16),
+ siuFE48(17),
+ niu10GE2(18),
+ siu10GE48(19),
+ siuGE10(20),
+ niu10Ge2Plus(21),
+ iuGT4(22),
+ iuGT6(23),
+ iuTDM6(24),
+ siuGE6(25),
+ siuGE8(26),
+ siuGT6(27),
+ niuGE2(28),
+ niuGE4(29),
+ iuGEPON4(30),
+ iu10GE8(31),
+ iuGEPON8(32),
+ iu10GEPON8(33),
+ iuGE8(34),
+ siu10GEPON8(35),
+ niu10GE4(36),
+ sfu10GE4(37),
+ siuGPON16(38),
+ iu10GE4(39),
+ siuGT24(40),
+ iu10GE2(41),
+ cwdm(42),
+ iuGT8(43)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Planning card type status of slot."
+ ::= { sleSlotStatusControl 7 }
+
+
+ sleSlotStatusControlUpgradeMode OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ manual(1),
+ auto(2),
+ autoUpgradeManualReset(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Upgrade mode status of slot."
+ ::= { sleSlotStatusControl 8 }
+
+
+ sleSlotStatusNotification OBJECT IDENTIFIER ::= { sleSlotStatusInfo 3 }
+
+
+ sleSlotStatusLocked NOTIFICATION-TYPE
+ OBJECTS { sleSlotStatusControlRequest, sleSlotStatusControlTimeStamp, sleSlotStatusControlReqResult, sleSlotStatusControlSlotIndex }
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleSlotStatusNotification 1 }
+
+
+ sleSlotStatusUnlocked NOTIFICATION-TYPE
+ OBJECTS { sleSlotStatusControlRequest, sleSlotStatusControlTimeStamp, sleSlotStatusControlReqResult, sleSlotStatusControlSlotIndex }
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleSlotStatusNotification 2 }
+
+
+ sleSlotStatusPlanning NOTIFICATION-TYPE
+ OBJECTS { sleSlotStatusControlRequest, sleSlotStatusControlTimeStamp, sleSlotStatusControlReqResult, sleSlotStatusControlSlotIndex, sleSlotStatusControlPlanCardType
+ }
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleSlotStatusNotification 3 }
+
+
+ sleSlotStatusNoPlanning NOTIFICATION-TYPE
+ OBJECTS { sleSlotStatusControlRequest, sleSlotStatusControlTimeStamp, sleSlotStatusControlReqResult, sleSlotStatusControlSlotIndex }
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleSlotStatusNotification 4 }
+
+
+ sleSlotStatusUpgradeModeChanged NOTIFICATION-TYPE
+ OBJECTS { sleSlotStatusControlRequest, sleSlotStatusControlTimeStamp, sleSlotStatusControlReqResult, sleSlotStatusControlSlotIndex, sleSlotStatusControlUpgradeMode
+ }
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleSlotStatusNotification 5 }
+
+
+ sleSlotStatusPowerUp NOTIFICATION-TYPE
+ OBJECTS { sleSlotStatusControlRequest, sleSlotStatusControlTimeStamp, sleSlotStatusControlReqResult, sleSlotStatusControlSlotIndex }
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleSlotStatusNotification 6 }
+
+
+ sleSlotStatusPowerDown NOTIFICATION-TYPE
+ OBJECTS { sleSlotStatusControlRequest, sleSlotStatusControlTimeStamp, sleSlotStatusControlReqResult, sleSlotStatusControlSlotIndex }
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleSlotStatusNotification 7 }
+
+
+ sleSlotStatusPowerReset NOTIFICATION-TYPE
+ OBJECTS { sleSlotStatusControlRequest, sleSlotStatusControlTimeStamp, sleSlotStatusControlReqResult, sleSlotStatusControlSlotIndex }
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleSlotStatusNotification 8 }
+
+
+ sleSlotNosInfo OBJECT IDENTIFIER ::= { sleSlot 3 }
+
+
+ sleSlotNosInfoTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SleSlotNosInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleSlotNosInfo 1 }
+
+
+ sleSlotNosInfoEntry OBJECT-TYPE
+ SYNTAX SleSlotNosInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Description."
+ INDEX { sleSlotSystemIndex }
+ ::= { sleSlotNosInfoTable 1 }
+
+
+ SleSlotNosInfoEntry ::=
+ SEQUENCE {
+ sleSlotNosVersion
+ OCTET STRING,
+ sleSlotNosRevision
+ OCTET STRING,
+ sleSlotNosSize
+ Unsigned32,
+ sleSlotNosUpgradeStatus
+ INTEGER,
+ sleSlotNosStbVersion
+ OCTET STRING,
+ sleSlotNosStbRevision
+ OCTET STRING,
+ sleSlotNosStbSize
+ Unsigned32
+ }
+
+ sleSlotNosVersion OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "NOS version of slot."
+ ::= { sleSlotNosInfoEntry 1 }
+
+
+ sleSlotNosRevision OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "NOS revision of slot."
+ ::= { sleSlotNosInfoEntry 2 }
+
+
+ sleSlotNosSize OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "NOS size of slot."
+ ::= { sleSlotNosInfoEntry 3 }
+
+
+ sleSlotNosUpgradeStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ upgradeIdle(1),
+ upgradeStart(2),
+ upgradeDone(3),
+ upgradeFail(4)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "NOS upgrade status of slot."
+ ::= { sleSlotNosInfoEntry 4 }
+
+
+ sleSlotNosStbVersion OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Stand by NOS version of slot"
+ ::= { sleSlotNosInfoEntry 5 }
+
+
+ sleSlotNosStbRevision OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Stand by NOS revision of slot."
+ ::= { sleSlotNosInfoEntry 6 }
+
+
+ sleSlotNosStbSize OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Stand by NOS size of slot."
+ ::= { sleSlotNosInfoEntry 7 }
+
+
+ sleSlotNosControl OBJECT IDENTIFIER ::= { sleSlotNosInfo 2 }
+
+
+ sleSlotNosControlRequest OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ setSlotUpgarde(1),
+ downloadSlotNos(2),
+ upgradeSlotBootloader(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The request of a user command"
+ ::= { sleSlotNosControl 1 }
+
+
+ sleSlotNosControlStatus OBJECT-TYPE
+ SYNTAX SleControlStatusType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The status of user command"
+ ::= { sleSlotNosControl 2 }
+
+
+ sleSlotNosControlTimer OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The maximum time for the manager for a long running user command"
+ ::= { sleSlotNosControl 3 }
+
+
+ sleSlotNosControlTimeStamp OBJECT-TYPE
+ SYNTAX TimeTicks
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The time stamp of the last command(end of command)"
+ ::= { sleSlotNosControl 4 }
+
+
+ sleSlotNosControlReqResult OBJECT-TYPE
+ SYNTAX SleControlRequestResultType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The result of the last user command"
+ ::= { sleSlotNosControl 5 }
+
+
+ sleSlotNosControlSlotIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The system slot index."
+ ::= { sleSlotNosControl 6 }
+
+
+ sleSlotNosControlUpDownMethod OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ ftp(1),
+ tftp(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "1: using FTP
+ 2: using TFTP
+ "
+ ::= { sleSlotNosControl 7 }
+
+
+ sleSlotNosControlUpDownFlag OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ upload(1),
+ download(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "1. Uploading slot nos to the remote-host.
+ 2. Downloading slot nos from the remote-host."
+ ::= { sleSlotNosControl 8 }
+
+
+ sleSlotNosControlServerAddress OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The remote-host's IP address."
+ ::= { sleSlotNosControl 9 }
+
+
+ sleSlotNosControlUserID OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Account-name."
+ ::= { sleSlotNosControl 10 }
+
+
+ sleSlotNosControlPassword OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Account-password."
+ ::= { sleSlotNosControl 11 }
+
+
+ sleSlotNosControlFileName OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Slot nos file name."
+ ::= { sleSlotNosControl 12 }
+
+
+ sleSlotNosNotification OBJECT IDENTIFIER ::= { sleSlotNosInfo 3 }
+
+
+ sleSlotNosUpgrade NOTIFICATION-TYPE
+ OBJECTS { sleSlotNosControlRequest, sleSlotNosControlTimeStamp, sleSlotNosControlReqResult, sleSlotNosControlSlotIndex }
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleSlotNosNotification 1 }
+
+
+ sleSlotNosDownload NOTIFICATION-TYPE
+ OBJECTS { sleSlotNosControlRequest, sleSlotNosControlTimeStamp, sleSlotNosControlReqResult, sleSlotNosControlUpDownMethod, sleSlotNosControlUpDownFlag,
+ sleSlotNosControlServerAddress, sleSlotNosControlUserID, sleSlotNosControlPassword, sleSlotNosControlFileName }
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleSlotNosNotification 2 }
+
+
+ sleSlotNosBootloaderUpgrade NOTIFICATION-TYPE
+ OBJECTS { sleSlotNosControlRequest, sleSlotNosControlTimeStamp, sleSlotNosControlReqResult, sleSlotNosControlSlotIndex, sleSlotNosControlServerAddress,
+ sleSlotNosControlUserID, sleSlotNosControlPassword, sleSlotNosControlFileName }
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleSlotNosNotification 3 }
+
+
+ sleSlotReleasedIUNosInfo OBJECT IDENTIFIER ::= { sleSlot 4 }
+
+
+ sleSlotReleasedNIUNosVersion OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Released NIU NOS image version on SFU."
+ ::= { sleSlotReleasedIUNosInfo 1 }
+
+
+ sleSlotReleasedNIUNosRevision OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Released NIU NOS image revision on SFU."
+ ::= { sleSlotReleasedIUNosInfo 2 }
+
+
+ sleSlotReleasedNIUNosSize OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Released NIU NOS image size on SFU."
+ ::= { sleSlotReleasedIUNosInfo 3 }
+
+
+ sleSlotReleasedGPIUNosVersion OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Released GPIU NOS image version on SFU."
+ ::= { sleSlotReleasedIUNosInfo 4 }
+
+
+ sleSlotReleasedGPIUNosRevision OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Released GPIU NOS image revision on SFU."
+ ::= { sleSlotReleasedIUNosInfo 5 }
+
+
+ sleSlotReleasedGPIUNosSize OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Released GPIU NOS image size on SFU."
+ ::= { sleSlotReleasedIUNosInfo 6 }
+
+
+ sleSlotReleasedSIUNosVersion OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Released SIU NOS image version on SFU."
+ ::= { sleSlotReleasedIUNosInfo 7 }
+
+
+ sleSlotReleasedSIUNosRevision OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Released SIU NOS image revision on SFU."
+ ::= { sleSlotReleasedIUNosInfo 8 }
+
+
+ sleSlotReleasedSIUNosSize OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Released SIU NOS image size on SFU."
+ ::= { sleSlotReleasedIUNosInfo 9 }
+
+
+ sleSlotReleasedIU10GE8NosVersion OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Released IU_10GE8 NOS image version on SFU."
+ ::= { sleSlotReleasedIUNosInfo 10 }
+
+
+ sleSlotReleasedIU10GE8NosRevision OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Released IU_10GE8 NOS image revision on SFU."
+ ::= { sleSlotReleasedIUNosInfo 11 }
+
+
+ sleSlotReleasedIU10GE8NosSize OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Released IU_10GE8 NOS image size on SFU."
+ ::= { sleSlotReleasedIUNosInfo 12 }
+
+
+ sleSlotReleasedIU10GEPON8NosVersion OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Released IU_10GEPON8 NOS image version on SFU."
+ ::= { sleSlotReleasedIUNosInfo 13 }
+
+
+ sleSlotReleasedIU10GEPON8NosRevision OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Released IU_10GEPON8 NOS image revision on SFU."
+ ::= { sleSlotReleasedIUNosInfo 14 }
+
+
+ sleSlotReleasedIU10GEPON8NosSize OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Released IU_10GEPON8 NOS image size on SFU."
+ ::= { sleSlotReleasedIUNosInfo 15 }
+
+
+ sleSlotReleasedIUGEPON8NosVersion OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Released IU_GEPON8 NOS image version on SFU."
+ ::= { sleSlotReleasedIUNosInfo 16 }
+
+
+ sleSlotReleasedIUGEPON8NosRevision OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Released IU_GEPON8 NOS image revision on SFU"
+ ::= { sleSlotReleasedIUNosInfo 17 }
+
+
+ sleSlotReleasedIUGEPON8NosSize OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Released IU_GEPON8 NOS image size on SFU."
+ ::= { sleSlotReleasedIUNosInfo 18 }
+
+
+ sleSlotPowerMon OBJECT IDENTIFIER ::= { sleSlot 5 }
+
+
+ sleSlotPowerMonTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SleSlotPowerMonEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The Power-Monitoring table."
+ ::= { sleSlotPowerMon 1 }
+
+
+ sleSlotPowerMonEntry OBJECT-TYPE
+ SYNTAX SleSlotPowerMonEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The Power-Monitoring entry."
+ INDEX { sleSlotSystemIndex, sleSlotPowerMonIndex }
+ ::= { sleSlotPowerMonTable 1 }
+
+
+ SleSlotPowerMonEntry ::=
+ SEQUENCE {
+ sleSlotPowerMonIndex
+ INTEGER,
+ sleSlotPowerMonStatus
+ INTEGER,
+ sleSlotPowerMonVoltage
+ Gauge32
+ }
+
+ sleSlotPowerMonIndex OBJECT-TYPE
+ SYNTAX INTEGER (1..255)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The physical index of power-monitoring object."
+ ::= { sleSlotPowerMonEntry 1 }
+
+
+ sleSlotPowerMonStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ unknown(1),
+ good(2),
+ bad(3),
+ over(4),
+ under(5),
+ overUnder(6)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The monitoring status of power-monitoring object."
+ ::= { sleSlotPowerMonEntry 2 }
+
+
+ sleSlotPowerMonVoltage OBJECT-TYPE
+ SYNTAX Gauge32
+ UNITS "0.1v"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The voltage value of power-monitoring object.
+ value 10000(1000v) indicate that FUSE."
+ ::= { sleSlotPowerMonEntry 3 }
+
+
+ sleSlotAiu OBJECT IDENTIFIER ::= { sleSlot 6 }
+
+
+ sleSlotAiuRunStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ off(0),
+ on(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The slot AIU run status."
+ ::= { sleSlotAiu 1 }
+
+
+ sleSlotAiuAlarmStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ off(0),
+ on(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The slot AIU alarm status."
+ ::= { sleSlotAiu 2 }
+
+
+ sleSlotProtection OBJECT IDENTIFIER ::= { sleSlot 7 }
+
+
+ sleSlotProtectionBase OBJECT IDENTIFIER ::= { sleSlotProtection 1 }
+
+
+ sleSlotProtectionInfo OBJECT IDENTIFIER ::= { sleSlotProtectionBase 1 }
+
+
+ sleSlotProtectionSystemStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ enable(1),
+ disable(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The system admin status(enable or disable) of overtemperature shutdown function."
+ ::= { sleSlotProtectionInfo 1 }
+
+
+ sleSlotProtectionSystemThreshold OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The system admin threshold of overtemperature shutdown function."
+ ::= { sleSlotProtectionInfo 2 }
+
+
+ sleSlotProtectionIUPowerStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ enable(1),
+ disable(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The slot power shutdown status"
+ ::= { sleSlotProtectionInfo 3 }
+
+
+ sleSlotProtectionControl OBJECT IDENTIFIER ::= { sleSlotProtectionBase 2 }
+
+
+ sleSlotProtectionControlRequest OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ setSlotProtectionSystemStatus(1),
+ setSlotProtectionSystemThresh(2),
+ setslotProtectionIUPowerStatus(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The request of a user command"
+ ::= { sleSlotProtectionControl 1 }
+
+
+ sleSlotProtectionControlStatus OBJECT-TYPE
+ SYNTAX SleControlStatusType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The status of user command"
+ ::= { sleSlotProtectionControl 2 }
+
+
+ sleSlotProtectionControlTimer OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The maximum time for the manager for a long running user command"
+ ::= { sleSlotProtectionControl 3 }
+
+
+ sleSlotProtectionControlTimeStamp OBJECT-TYPE
+ SYNTAX TimeTicks
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The time stamp of the last command(end of command)"
+ ::= { sleSlotProtectionControl 4 }
+
+
+ sleSlotProtectionControlReqResult OBJECT-TYPE
+ SYNTAX SleControlRequestResultType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The result of the last user command"
+ ::= { sleSlotProtectionControl 5 }
+
+
+ sleSlotProtectionControlSystemStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ enable(1),
+ disable(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The system admin status(enable or disable) of overtemperature shutdown function."
+ ::= { sleSlotProtectionControl 6 }
+
+
+ sleSlotProtectionControlSystemThreshold OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The system admin threshold of overtemperature shutdown function."
+ ::= { sleSlotProtectionControl 7 }
+
+
+ sleSlotProtectionControlIUPowerStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ enable(1),
+ disable(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The slot power shutdown status"
+ ::= { sleSlotProtectionControl 8 }
+
+
+ sleSlotProtectionNotification OBJECT IDENTIFIER ::= { sleSlotProtectionBase 3 }
+
+
+ sleSlotProtectionSystemStatusChanged NOTIFICATION-TYPE
+ OBJECTS { sleSlotProtectionControlRequest, sleSlotProtectionControlTimeStamp, sleSlotProtectionControlReqResult, sleSlotProtectionControlSystemStatus }
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleSlotProtectionNotification 1 }
+
+
+ sleSlotProtectionSystemThreshChanged NOTIFICATION-TYPE
+ OBJECTS { sleSlotProtectionControlRequest, sleSlotProtectionControlTimeStamp, sleSlotProtectionControlReqResult, sleSlotProtectionControlSystemThreshold }
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleSlotProtectionNotification 2 }
+
+
+ sleSlotProtectionIUPowerStatusChanged NOTIFICATION-TYPE
+ OBJECTS { sleSlotProtectionControlRequest, sleSlotProtectionControlTimeStamp, sleSlotProtectionControlReqResult, sleSlotProtectionControlIUPowerStatus }
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleSlotProtectionNotification 3 }
+
+
+ sleSlotProtectionIU OBJECT IDENTIFIER ::= { sleSlotProtection 2 }
+
+
+ sleSlotProtectionIUTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SleSlotProtectionIUEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleSlotProtectionIU 1 }
+
+
+ sleSlotProtectionIUEntry OBJECT-TYPE
+ SYNTAX SleSlotProtectionIUEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Description."
+ AUGMENTS { sleSlotSystemInfoEntry }
+ ::= { sleSlotProtectionIUTable 1 }
+
+
+ SleSlotProtectionIUEntry ::=
+ SEQUENCE {
+ sleSlotProtectionIUTemperHighThresh
+ Integer32,
+ sleSlotProtectionIUTemperLowThresh
+ Integer32,
+ sleSlotProtectionIUPowerThresh
+ Integer32,
+ sleSlotProtectionIUTemper
+ Integer32,
+ sleSlotProtectionIUTemper2
+ Integer32
+ }
+
+ sleSlotProtectionIUTemperHighThresh OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The Slot temperature High-threshold of overtemperature alarm"
+ ::= { sleSlotProtectionIUEntry 1 }
+
+
+ sleSlotProtectionIUTemperLowThresh OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The Slot temperature Low-threshold of overtemperature alarm"
+ ::= { sleSlotProtectionIUEntry 2 }
+
+
+ sleSlotProtectionIUPowerThresh OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The Slot temperature threshold of overtemperature power shutdown."
+ ::= { sleSlotProtectionIUEntry 3 }
+
+
+ sleSlotProtectionIUTemper OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The Slot temperature."
+ ::= { sleSlotProtectionIUEntry 4 }
+
+
+ sleSlotProtectionIUTemper2 OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The Slot temperature2."
+ ::= { sleSlotProtectionIUEntry 5 }
+
+
+ sleSlotProtectionIUControl OBJECT IDENTIFIER ::= { sleSlotProtectionIU 2 }
+
+
+ sleSlotProtectionIUControlRequest OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ setSlotTempThreshold(1),
+ setSlotPowerThresh(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The request of a user command"
+ ::= { sleSlotProtectionIUControl 1 }
+
+
+ sleSlotProtectionIUControlStatus OBJECT-TYPE
+ SYNTAX SleControlStatusType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The status of user command"
+ ::= { sleSlotProtectionIUControl 2 }
+
+
+ sleSlotProtectionIUControlTimer OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The maximum time for the manager for a long running user command"
+ ::= { sleSlotProtectionIUControl 3 }
+
+
+ sleSlotProtectionIUControlTimeStamp OBJECT-TYPE
+ SYNTAX TimeTicks
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The time stamp of the last command(end of command)"
+ ::= { sleSlotProtectionIUControl 4 }
+
+
+ sleSlotProtectionIUControlReqResult OBJECT-TYPE
+ SYNTAX SleControlRequestResultType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The result of the last user command"
+ ::= { sleSlotProtectionIUControl 5 }
+
+
+ sleSlotProtectionIUControlindex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "the slot index"
+ ::= { sleSlotProtectionIUControl 6 }
+
+
+ sleSlotProtectionIUControlTemperHighThresh OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The Slot temperature High-threshold of overtemperature alarm"
+ ::= { sleSlotProtectionIUControl 7 }
+
+
+ sleSlotProtectionIUControlTemperLowThresh OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The Slot temperature Low-threshold of overtemperature alarm"
+ ::= { sleSlotProtectionIUControl 8 }
+
+
+ sleSlotProtectionIUControlPowerThresh OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The Slot temperature threshold of overtemperature power shutdown."
+ ::= { sleSlotProtectionIUControl 9 }
+
+
+ sleSlotProtectionIUNotification OBJECT IDENTIFIER ::= { sleSlotProtectionIU 3 }
+
+
+ sleSlotProtectionIUTemperThreshChanged NOTIFICATION-TYPE
+ OBJECTS { sleSlotProtectionIUControlRequest, sleSlotProtectionIUControlTimeStamp, sleSlotProtectionIUControlReqResult, sleSlotProtectionIUControlTemperHighThresh, sleSlotProtectionIUControlTemperLowThresh,
+ sleSlotProtectionIUControlindex }
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleSlotProtectionIUNotification 1 }
+
+
+ sleSlotProtectionIUPowerThreshChanged NOTIFICATION-TYPE
+ OBJECTS { sleSlotProtectionIUControlRequest, sleSlotProtectionIUControlTimeStamp, sleSlotProtectionIUControlReqResult, sleSlotProtectionIUControlindex, sleSlotProtectionIUControlPowerThresh
+ }
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleSlotProtectionIUNotification 2 }
+
+
+ sleRF OBJECT IDENTIFIER ::= { sleDevice 12 }
+
+
+ sleRfBaseInfo OBJECT IDENTIFIER ::= { sleRF 1 }
+
+
+ sleRfConnectStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ connect(1),
+ disconnect(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The RF connect status."
+ ::= { sleRfBaseInfo 1 }
+
+
+ sleRfPowerStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ poweroff(0),
+ poweron(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The RF power status."
+ ::= { sleRfBaseInfo 2 }
+
+
+ sleRfEthertype OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The RF ethertype."
+ ::= { sleRfBaseInfo 3 }
+
+
+ sleRfSrcAddress OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The RF source address."
+ ::= { sleRfBaseInfo 4 }
+
+
+ sleRfDesAddress OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The RF destination address."
+ ::= { sleRfBaseInfo 5 }
+
+
+ sleRfBaseControl OBJECT IDENTIFIER ::= { sleRF 2 }
+
+
+ sleRfBaseControlRequest OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ setRfEthertype(1),
+ resetRfEthertype(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The request of a user command."
+ ::= { sleRfBaseControl 1 }
+
+
+ sleRfBaseControlStatus OBJECT-TYPE
+ SYNTAX SleControlStatusType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The status of user command."
+ ::= { sleRfBaseControl 2 }
+
+
+ sleRfBaseControlTimer OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The maximum time for the manager for a long running user command."
+ ::= { sleRfBaseControl 3 }
+
+
+ sleRfBaseControlTimeStamp OBJECT-TYPE
+ SYNTAX TimeTicks
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The time stamp of the last command(end of command)."
+ ::= { sleRfBaseControl 4 }
+
+
+ sleRfBaseControlReqResult OBJECT-TYPE
+ SYNTAX SleControlRequestResultType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The result of user command."
+ ::= { sleRfBaseControl 5 }
+
+
+ sleRfBaseControlRfEthertype OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The Rf ethertype ,the format is 0xXXXX, default value is 0x8864."
+ ::= { sleRfBaseControl 6 }
+
+
+ sleRfBaseNotification OBJECT IDENTIFIER ::= { sleRF 3 }
+
+
+ sleRFBaseEthertypeChanged NOTIFICATION-TYPE
+ OBJECTS { sleRfBaseControlRequest, sleRfBaseControlTimeStamp, sleRfBaseControlReqResult, sleRfBaseControlRfEthertype }
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleRfBaseNotification 1 }
+
+
+ sleRFBaseEthertypeResetChanged NOTIFICATION-TYPE
+ OBJECTS { sleRfBaseControlRequest, sleRfBaseControlTimeStamp, sleRfBaseControlReqResult, sleRfBaseControlRfEthertype }
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleRfBaseNotification 2 }
+
+
+ sleRfPortTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SleRfPortEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleRF 4 }
+
+
+ sleRfPortEntry OBJECT-TYPE
+ SYNTAX SleRfPortEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Description."
+ INDEX { sleRfPortIndex }
+ ::= { sleRfPortTable 1 }
+
+
+ SleRfPortEntry ::=
+ SEQUENCE {
+ sleRfPortIndex
+ INTEGER,
+ sleRfPortAdminStatus
+ INTEGER,
+ sleRfPortOperStatus
+ INTEGER
+ }
+
+ sleRfPortIndex OBJECT-TYPE
+ SYNTAX INTEGER (1..256)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The RF port index."
+ ::= { sleRfPortEntry 1 }
+
+
+ sleRfPortAdminStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ enable(1),
+ disable(2),
+ na(255)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The RF port adminStatus."
+ ::= { sleRfPortEntry 2 }
+
+
+ sleRfPortOperStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ enable(1),
+ disable(2),
+ na(255)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The RF port operStatus."
+ ::= { sleRfPortEntry 3 }
+
+
+ sleRFPortControl OBJECT IDENTIFIER ::= { sleRF 5 }
+
+
+ sleRfPortControlRequest OBJECT-TYPE
+ SYNTAX INTEGER { setRfPortStatus(1) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The request of a user command."
+ ::= { sleRFPortControl 1 }
+
+
+ sleRfPortControlStatus OBJECT-TYPE
+ SYNTAX SleControlStatusType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The status of user command."
+ ::= { sleRFPortControl 2 }
+
+
+ sleRfPortControlTimer OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The maximum time for the manager for a long running user command."
+ ::= { sleRFPortControl 3 }
+
+
+ sleRfPortControlTimeStamp OBJECT-TYPE
+ SYNTAX TimeTicks
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The time stamp of the last command(end of command)."
+ ::= { sleRFPortControl 4 }
+
+
+ sleRfPortControlReqResult OBJECT-TYPE
+ SYNTAX SleControlRequestResultType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The result of user command.
+ "
+ ::= { sleRFPortControl 5 }
+
+
+ sleRfPortControlIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..8)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The RF port index <1-8>."
+ ::= { sleRFPortControl 6 }
+
+
+ sleRfPortControlAdminStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ enable(1),
+ disable(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The RF port adminStatus."
+ ::= { sleRFPortControl 7 }
+
+
+ sleRFPortNotification OBJECT IDENTIFIER ::= { sleRF 6 }
+
+
+ sleRfPortStatusChanged NOTIFICATION-TYPE
+ OBJECTS { sleRfPortControlRequest, sleRfPortControlTimeStamp, sleRfPortControlReqResult, sleRfPortControlIndex, sleRfPortControlAdminStatus
+ }
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleRFPortNotification 1 }
+
+
+ sleEnvironmentMonitor OBJECT IDENTIFIER ::= { sleDevice 13 }
+
+
+ sleEMTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SleEMEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleEnvironmentMonitor 1 }
+
+
+ sleEMEntry OBJECT-TYPE
+ SYNTAX SleEMEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Description."
+ INDEX { sleEMInputIndex }
+ ::= { sleEMTable 1 }
+
+
+ SleEMEntry ::=
+ SEQUENCE {
+ sleEMInputIndex
+ Integer32,
+ sleEMAlarmString
+ OCTET STRING,
+ sleEMAlarmSeverity
+ INTEGER,
+ sleEMmode
+ INTEGER
+ }
+
+ sleEMInputIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..4)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The environment monitoring input index(1-4)."
+ ::= { sleEMEntry 1 }
+
+
+ sleEMAlarmString OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The alarm string"
+ ::= { sleEMEntry 2 }
+
+
+ sleEMAlarmSeverity OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ none(0),
+ critical(1),
+ major(2),
+ minor(3),
+ warning(4),
+ intermediate(5)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The alarm severity."
+ ::= { sleEMEntry 3 }
+
+
+ sleEMmode OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ normalClose(0),
+ normalOpen(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The environment monitoring mode.(default:normal-close)"
+ ::= { sleEMEntry 4 }
+
+
+ sleEMControl OBJECT IDENTIFIER ::= { sleEnvironmentMonitor 2 }
+
+
+ sleEMControlRequest OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ setEM(1),
+ delEM(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The request of a user command."
+ ::= { sleEMControl 1 }
+
+
+ sleEMControlStatus OBJECT-TYPE
+ SYNTAX SleControlStatusType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleEMControl 2 }
+
+
+ sleEMControlTimer OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The maximum time for the manager for a long running user command.
+ Apply your setting.
+ "
+ ::= { sleEMControl 3 }
+
+
+ sleEMControlTimeStamp OBJECT-TYPE
+ SYNTAX TimeTicks
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleEMControl 4 }
+
+
+ sleEMControlReqResult OBJECT-TYPE
+ SYNTAX SleControlRequestResultType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleEMControl 5 }
+
+
+ sleEMControlInputIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..4)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The environment monitoring input index(1-4)."
+ ::= { sleEMControl 6 }
+
+
+ sleEMControlAlarmString OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The alarm string"
+ ::= { sleEMControl 7 }
+
+
+ sleEMControlAlarmSeverity OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ none(0),
+ critical(1),
+ major(2),
+ minor(3),
+ warning(4),
+ intermediate(5)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The alarm severity."
+ ::= { sleEMControl 8 }
+
+
+ sleEMControlmode OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ normalClose(0),
+ normalOpen(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The environment monitoring mode.(default:normal-close)"
+ ::= { sleEMControl 9 }
+
+
+ sleEMNotification OBJECT IDENTIFIER ::= { sleEnvironmentMonitor 3 }
+
+
+ sleEMChanged NOTIFICATION-TYPE
+ OBJECTS { sleEMControlRequest, sleEMControlTimeStamp, sleEMControlReqResult, sleEMControlInputIndex, sleEMControlAlarmString,
+ sleEMControlAlarmSeverity, sleEMControlmode }
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleEMNotification 1 }
+
+
+ sleEMDeleted NOTIFICATION-TYPE
+ OBJECTS { sleEMControlRequest, sleEMControlTimeStamp, sleEMControlReqResult, sleEMControlInputIndex }
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleEMNotification 2 }
+
+
+ sleBypass OBJECT IDENTIFIER ::= { sleDevice 14 }
+
+
+ sleBypassBase OBJECT IDENTIFIER ::= { sleBypass 1 }
+
+
+ sleBypassBaseInfo OBJECT IDENTIFIER ::= { sleBypassBase 1 }
+
+
+ sleBypassMode OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ on(1),
+ off(2),
+ auto(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "optic bypass mode"
+ DEFVAL { 2 }
+ ::= { sleBypassBaseInfo 1 }
+
+
+ sleBypassStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ enable(1),
+ disable(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "optic bypass status
+ "
+ ::= { sleBypassBaseInfo 2 }
+
+
+ sleBypassBaseControl OBJECT IDENTIFIER ::= { sleBypassBase 2 }
+
+
+ sleBypassBaseControlRequest OBJECT-TYPE
+ SYNTAX INTEGER { setBypassMode(1) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleBypassBaseControl 1 }
+
+
+ sleBypassBaseControlStatus OBJECT-TYPE
+ SYNTAX SleControlStatusType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The status of user command."
+ ::= { sleBypassBaseControl 2 }
+
+
+ sleBypassBaseControlTimer OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The maximum time for the manager for a long running user command."
+ ::= { sleBypassBaseControl 3 }
+
+
+ sleBypassBaseControlTimeStamp OBJECT-TYPE
+ SYNTAX TimeTicks
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The time stamp of the last command(end of command)."
+ ::= { sleBypassBaseControl 4 }
+
+
+ sleBypassBaseControlReqResult OBJECT-TYPE
+ SYNTAX SleControlRequestResultType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The result of user command."
+ ::= { sleBypassBaseControl 5 }
+
+
+ sleBypassBaseControlMode OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ on(1),
+ off(2),
+ auto(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "optic bypass mode"
+ ::= { sleBypassBaseControl 6 }
+
+
+ sleBypassBaseNotification OBJECT IDENTIFIER ::= { sleBypassBase 3 }
+
+
+ sleBypassModeChanged NOTIFICATION-TYPE
+ OBJECTS { sleBypassBaseControlRequest, sleBypassBaseControlTimeStamp, sleBypassBaseControlReqResult, sleBypassBaseControlMode }
+ STATUS current
+ DESCRIPTION
+ "setBypassMode(1)"
+ ::= { sleBypassBaseNotification 1 }
+
+
+ sleBypassOption OBJECT IDENTIFIER ::= { sleBypass 2 }
+
+
+ sleBypassOptionConnectivityTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SleBypassOptionConnectivityEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The connectivity option of bypass"
+ ::= { sleBypassOption 1 }
+
+
+ sleBypassOptionConnectivityEntry OBJECT-TYPE
+ SYNTAX SleBypassOptionConnectivityEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Description."
+ INDEX { sleBypassOptionConnectivityAddress, sleBypassOptionConnectivityPort }
+ ::= { sleBypassOptionConnectivityTable 1 }
+
+
+ SleBypassOptionConnectivityEntry ::=
+ SEQUENCE {
+ sleBypassOptionConnectivityAddress
+ IpAddress,
+ sleBypassOptionConnectivityPort
+ Integer32
+ }
+
+ sleBypassOptionConnectivityAddress OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The target IP address of bypass health-checking"
+ ::= { sleBypassOptionConnectivityEntry 1 }
+
+
+ sleBypassOptionConnectivityPort OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The target port of bypass health-checking."
+ ::= { sleBypassOptionConnectivityEntry 2 }
+
+
+ sleBypassOptionConnectivityControl OBJECT IDENTIFIER ::= { sleBypassOption 2 }
+
+
+ sleBypassOptionConnectivityControlRequest OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ setBypassConnectivity(1),
+ unsetBypassConnectivity(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "setBypassConnectivity(1) : bypass-check-option connectivity (A.B.C.D) PORT
+ unsetBypassConnectivity(2) : no bypass-check option connectivity"
+ ::= { sleBypassOptionConnectivityControl 1 }
+
+
+ sleBypassOptionConnectivityControlStatus OBJECT-TYPE
+ SYNTAX SleControlStatusType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The status of user command."
+ ::= { sleBypassOptionConnectivityControl 2 }
+
+
+ sleBypassOptionConnectivityControlTimer OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The maximum time for the manager for a long running user command."
+ ::= { sleBypassOptionConnectivityControl 3 }
+
+
+ sleBypassOptionConnectivityControlTimeStamp OBJECT-TYPE
+ SYNTAX TimeTicks
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The time stamp of the last command(end of command)."
+ ::= { sleBypassOptionConnectivityControl 4 }
+
+
+ sleBypassOptionConnectivityControlReqResult OBJECT-TYPE
+ SYNTAX SleControlRequestResultType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The result of user command."
+ ::= { sleBypassOptionConnectivityControl 5 }
+
+
+ sleBypassOptionConnectivityControlAddress OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The target IP address of bypass health-checking"
+ ::= { sleBypassOptionConnectivityControl 6 }
+
+
+ sleBypassOptionConnectivityControlPort OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "he target port of bypass health-checking"
+ ::= { sleBypassOptionConnectivityControl 7 }
+
+
+ sleBypassOptionConnectivityNotification OBJECT IDENTIFIER ::= { sleBypassOption 3 }
+
+
+ sleBypassOptionConnectivitySet NOTIFICATION-TYPE
+ OBJECTS { sleBypassOptionConnectivityControlRequest, sleBypassOptionConnectivityControlTimeStamp, sleBypassOptionConnectivityControlReqResult, sleBypassOptionConnectivityControlAddress, sleBypassOptionConnectivityControlPort
+ }
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleBypassOptionConnectivityNotification 1 }
+
+
+ sleBypassOptionConnectivityUnset NOTIFICATION-TYPE
+ OBJECTS { sleBypassOptionConnectivityControlRequest, sleBypassOptionConnectivityControlTimeStamp, sleBypassOptionConnectivityControlReqResult, sleBypassOptionConnectivityControlAddress, sleBypassOptionConnectivityControlPort
+ }
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleBypassOptionConnectivityNotification 2 }
+
+
+ sleBypassOptionPingTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SleBypassOptionPingEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleBypassOption 4 }
+
+
+ sleBypassOptionPingEntry OBJECT-TYPE
+ SYNTAX SleBypassOptionPingEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Description."
+ INDEX { sleBypassOptionPingAddress }
+ ::= { sleBypassOptionPingTable 1 }
+
+
+ SleBypassOptionPingEntry ::=
+ SEQUENCE {
+ sleBypassOptionPingAddress
+ IpAddress,
+ sleBypassOptionPingTransInterval
+ Integer32,
+ sleBypassOptionPingTranNumber
+ Integer32,
+ sleBypassOptionPingReqInterval
+ Integer32,
+ sleBypassOptionPingReqTimeout
+ Integer32,
+ sleBypassOptionPingLossThresh
+ Integer32
+ }
+
+ sleBypassOptionPingAddress OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The target IP address of bypass ping health checking"
+ ::= { sleBypassOptionPingEntry 1 }
+
+
+ sleBypassOptionPingTransInterval OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The ping transaction interval"
+ ::= { sleBypassOptionPingEntry 2 }
+
+
+ sleBypassOptionPingTranNumber OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The ping transaction request number"
+ ::= { sleBypassOptionPingEntry 3 }
+
+
+ sleBypassOptionPingReqInterval OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The ping request interval"
+ ::= { sleBypassOptionPingEntry 4 }
+
+
+ sleBypassOptionPingReqTimeout OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The ping request timeout"
+ ::= { sleBypassOptionPingEntry 5 }
+
+
+ sleBypassOptionPingLossThresh OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The ping loss threshold"
+ ::= { sleBypassOptionPingEntry 6 }
+
+
+ sleBypassOptionPingControl OBJECT IDENTIFIER ::= { sleBypassOption 5 }
+
+
+ sleBypassOptionPingControlRequest OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ setBypassPing(1),
+ unsetBypassPing(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The request of a user command."
+ ::= { sleBypassOptionPingControl 1 }
+
+
+ sleBypassOptionPingControlStatus OBJECT-TYPE
+ SYNTAX SleControlStatusType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The status of user command."
+ ::= { sleBypassOptionPingControl 2 }
+
+
+ sleBypassOptionPingControlTimer OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The maximum time for the manager for a long running user command."
+ ::= { sleBypassOptionPingControl 3 }
+
+
+ sleBypassOptionPingControlTimeStamp OBJECT-TYPE
+ SYNTAX TimeTicks
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The time stamp of the last command(end of command)."
+ ::= { sleBypassOptionPingControl 4 }
+
+
+ sleBypassOptionPingControlReqResult OBJECT-TYPE
+ SYNTAX SleControlRequestResultType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The result of user command."
+ ::= { sleBypassOptionPingControl 5 }
+
+
+ sleBypassOptionPingControlAddress OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The target IP address of bypass ping health-checking"
+ ::= { sleBypassOptionPingControl 6 }
+
+
+ sleBypassOptionPingControlTransInterval OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The ping transaction interval"
+ ::= { sleBypassOptionPingControl 7 }
+
+
+ sleBypassOptionPingControlTranNumber OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The ping transaction request number"
+ ::= { sleBypassOptionPingControl 8 }
+
+
+ sleBypassOptionPingControlReqInterval OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The ping request interval"
+ ::= { sleBypassOptionPingControl 9 }
+
+
+ sleBypassOptionPingControlReqTimeout OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The ping request timeout"
+ ::= { sleBypassOptionPingControl 10 }
+
+
+ sleBypassOptionPingControlLossThresh OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The ping loss threshold"
+ ::= { sleBypassOptionPingControl 11 }
+
+
+ sleBypassOptionPingNotification OBJECT IDENTIFIER ::= { sleBypassOption 6 }
+
+
+ sleBypassOptionPingSet NOTIFICATION-TYPE
+ OBJECTS { sleBypassOptionPingControlRequest, sleBypassOptionPingControlTimeStamp, sleBypassOptionPingControlReqResult, sleBypassOptionPingControlTranNumber, sleBypassOptionPingControlReqInterval,
+ sleBypassOptionPingControlReqTimeout, sleBypassOptionPingControlLossThresh, sleBypassOptionPingControlAddress, sleBypassOptionPingControlTransInterval }
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleBypassOptionPingNotification 1 }
+
+
+ sleBypassOptionPingUnset NOTIFICATION-TYPE
+ OBJECTS { sleBypassOptionPingControlRequest, sleBypassOptionPingControlTimeStamp, sleBypassOptionPingControlReqResult, sleBypassOptionPingControlAddress }
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleBypassOptionPingNotification 2 }
+
+
+ sleBypassOptionLinkMonitorTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SleBypassOptionLinkMonitorEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleBypassOption 7 }
+
+
+ sleBypassOptionLinkMonitorEntry OBJECT-TYPE
+ SYNTAX SleBypassOptionLinkMonitorEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Description."
+ INDEX { sleBypassOptionLinkMonitorPort }
+ ::= { sleBypassOptionLinkMonitorTable 1 }
+
+
+ SleBypassOptionLinkMonitorEntry ::=
+ SEQUENCE {
+ sleBypassOptionLinkMonitorPort
+ Integer32,
+ sleBypassOptionLinkMonitorPortStatus
+ INTEGER
+ }
+
+ sleBypassOptionLinkMonitorPort OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The port of bypass link health-checking"
+ ::= { sleBypassOptionLinkMonitorEntry 1 }
+
+
+ sleBypassOptionLinkMonitorPortStatus OBJECT-TYPE
+ SYNTAX INTEGER { enable(1) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The port status of bypass link health-checking"
+ ::= { sleBypassOptionLinkMonitorEntry 2 }
+
+
+ sleBypassOptionLinkMonitorControl OBJECT IDENTIFIER ::= { sleBypassOption 8 }
+
+
+ sleBypassOptionLinkMonitorControlRequest OBJECT-TYPE
+ SYNTAX INTEGER { setBypassLinkMonitor(1) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The request of a user command."
+ ::= { sleBypassOptionLinkMonitorControl 1 }
+
+
+ sleBypassOptionLinkMonitorControlStatus OBJECT-TYPE
+ SYNTAX SleControlStatusType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The status of user command."
+ ::= { sleBypassOptionLinkMonitorControl 2 }
+
+
+ sleBypassOptionLinkMonitorControlTimer OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The maximum time for the manager for a long running user command."
+ ::= { sleBypassOptionLinkMonitorControl 3 }
+
+
+ sleBypassOptionLinkMonitorControlTimeStamp OBJECT-TYPE
+ SYNTAX TimeTicks
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The time stamp of the last command(end of command)."
+ ::= { sleBypassOptionLinkMonitorControl 4 }
+
+
+ sleBypassOptionLinkMonitorControlReqResult OBJECT-TYPE
+ SYNTAX SleControlRequestResultType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The result of user command."
+ ::= { sleBypassOptionLinkMonitorControl 5 }
+
+
+ sleBypassOptionLinkMonitorControlPort OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The port of bypass link health-checking"
+ ::= { sleBypassOptionLinkMonitorControl 6 }
+
+
+ sleBypassOptionLinkMonitorControlPortStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ enable(1),
+ disable(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The port status of bypass link health-checking"
+ ::= { sleBypassOptionLinkMonitorControl 7 }
+
+
+ sleBypassOptioLinkMonitorNotification OBJECT IDENTIFIER ::= { sleBypassOption 9 }
+
+
+ sleBypassOptionLinkMonitorChanged NOTIFICATION-TYPE
+ OBJECTS { sleBypassOptionLinkMonitorControlRequest, sleBypassOptionLinkMonitorControlStatus, sleBypassOptionLinkMonitorControlTimeStamp, sleBypassOptionLinkMonitorControlReqResult, sleBypassOptionLinkMonitorControlPort,
+ sleBypassOptionLinkMonitorControlPortStatus }
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleBypassOptioLinkMonitorNotification 1 }
+
+
+ sleHFC OBJECT IDENTIFIER ::= { sleDevice 15 }
+
+
+ sleHFCTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SleHFCEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleHFC 1 }
+
+
+ sleHFCEntry OBJECT-TYPE
+ SYNTAX SleHFCEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Description."
+ INDEX { sleHFCOptic1550OTX }
+ ::= { sleHFCTable 1 }
+
+
+ SleHFCEntry ::=
+ SEQUENCE {
+ sleHFCOptic1550OTX
+ OCTET STRING,
+ sleHFCOptic1550OTXAlarm
+ INTEGER,
+ sleHFCOpticUpstreamOTX
+ OCTET STRING,
+ sleHFCOpticUpstreamOTXAlarm
+ INTEGER,
+ sleHFCOpticDownstreamORX
+ OCTET STRING,
+ sleHFCOpticDownstreamORXAlarm
+ INTEGER,
+ sleHFCEDFA1OTX
+ OCTET STRING,
+ sleHFCEDFA1OTXAlarm
+ INTEGER,
+ sleHFCEDFA1ORX
+ OCTET STRING,
+ sleHFCEDFA1ORXAlarm
+ INTEGER,
+ sleHFCEDFA1LD1Current
+ OCTET STRING,
+ sleHFCEDFA1LD1CurrentAlarm
+ INTEGER,
+ sleHFCEDFA1LD2Current
+ OCTET STRING,
+ sleHFCEDFA1LD2CurrentAlarm
+ INTEGER,
+ sleHFCEDFA1LD1Temp
+ OCTET STRING,
+ sleHFCEDFA1LD1TempAlarm
+ INTEGER,
+ sleHFCEDFA1LD2Temp
+ OCTET STRING,
+ sleHFCEDFA1LD2TempAlarm
+ INTEGER,
+ sleHFCEDFA1CaseTemp
+ OCTET STRING,
+ sleHFCEDFA1CaseTempAlarm
+ INTEGER,
+ sleHFCEDFA2OTX
+ OCTET STRING,
+ sleHFCEDFA2OTXAarm
+ INTEGER,
+ sleHFCEDFA2ORX
+ OCTET STRING,
+ sleHFCEDFA2ORXAlarm
+ INTEGER,
+ sleHFCEDFA2LD1Current
+ OCTET STRING,
+ sleHFCEDFA2LD1CurrentAlarm
+ INTEGER,
+ sleHFCEDFA2LD2Current
+ OCTET STRING,
+ sleHFCEDFA2LD2CurrentAlarm
+ INTEGER,
+ sleHFCEDFA2LD1Temp
+ OCTET STRING,
+ sleHFCEDFA2LD1TempAlarm
+ INTEGER,
+ sleHFCEDFA2LD2Temp
+ OCTET STRING,
+ sleHFCEDFA2LD2TempAlarm
+ INTEGER,
+ sleHFCEDFA2CaseTemp
+ OCTET STRING,
+ sleHFCEDFA2CaseTempAlarm
+ INTEGER
+ }
+
+ sleHFCOptic1550OTX OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "HFC Optic 1550 OTX value."
+ ::= { sleHFCEntry 1 }
+
+
+ sleHFCOptic1550OTXAlarm OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ off(0),
+ on(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "HFC Optic 1550 OTX alarm status."
+ ::= { sleHFCEntry 2 }
+
+
+ sleHFCOpticUpstreamOTX OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "HFC Optic Upstream OTX value."
+ ::= { sleHFCEntry 3 }
+
+
+ sleHFCOpticUpstreamOTXAlarm OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ off(0),
+ on(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "HFC Optic Upstream OTX alarm status."
+ ::= { sleHFCEntry 4 }
+
+
+ sleHFCOpticDownstreamORX OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "HFC Optic Downstream ORX value."
+ ::= { sleHFCEntry 5 }
+
+
+ sleHFCOpticDownstreamORXAlarm OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ off(0),
+ on(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "HFC Optic Downstream ORX alarm status."
+ ::= { sleHFCEntry 6 }
+
+
+ sleHFCEDFA1OTX OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "HFC EDFA1 OTX value."
+ ::= { sleHFCEntry 7 }
+
+
+ sleHFCEDFA1OTXAlarm OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ off(0),
+ on(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "HFC EDFA1 OTX alarm status."
+ ::= { sleHFCEntry 8 }
+
+
+ sleHFCEDFA1ORX OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "HFC EDFA1 ORX value."
+ ::= { sleHFCEntry 9 }
+
+
+ sleHFCEDFA1ORXAlarm OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ off(0),
+ on(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "HFC EDFA1 ORX alarm status."
+ ::= { sleHFCEntry 10 }
+
+
+ sleHFCEDFA1LD1Current OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "HFC EDFA1 LD1 Current value."
+ ::= { sleHFCEntry 11 }
+
+
+ sleHFCEDFA1LD1CurrentAlarm OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ off(0),
+ on(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "HFC EDFA1 LD1 Current alarm status."
+ ::= { sleHFCEntry 12 }
+
+
+ sleHFCEDFA1LD2Current OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "HFC EDFA1 LD2 Current value."
+ ::= { sleHFCEntry 13 }
+
+
+ sleHFCEDFA1LD2CurrentAlarm OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ off(0),
+ on(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "HFC EDFA1 LD2 Current alarm status."
+ ::= { sleHFCEntry 14 }
+
+
+ sleHFCEDFA1LD1Temp OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "HFC EDFA1 LD1 Temp value."
+ ::= { sleHFCEntry 15 }
+
+
+ sleHFCEDFA1LD1TempAlarm OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ off(0),
+ on(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "HFC EDFA1 LD1 Temp alarm status."
+ ::= { sleHFCEntry 16 }
+
+
+ sleHFCEDFA1LD2Temp OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "HFC EDFA1 LD2 Temp value."
+ ::= { sleHFCEntry 17 }
+
+
+ sleHFCEDFA1LD2TempAlarm OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ off(0),
+ on(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "HFC EDFA1 LD2 Temp alarm status."
+ ::= { sleHFCEntry 18 }
+
+
+ sleHFCEDFA1CaseTemp OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "HFC EDFA1 Case Temp value."
+ ::= { sleHFCEntry 19 }
+
+
+ sleHFCEDFA1CaseTempAlarm OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ off(0),
+ on(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "HFC EDFA1 Case Temp alarm status."
+ ::= { sleHFCEntry 20 }
+
+
+ sleHFCEDFA2OTX OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "HFC EDFA2 OTX value."
+ ::= { sleHFCEntry 21 }
+
+
+ sleHFCEDFA2OTXAarm OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ off(0),
+ on(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "HFC EDFA2 OTX alarm status."
+ ::= { sleHFCEntry 22 }
+
+
+ sleHFCEDFA2ORX OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "HFC EDFA2 ORX value."
+ ::= { sleHFCEntry 23 }
+
+
+ sleHFCEDFA2ORXAlarm OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ off(0),
+ on(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "HFC EDFA2 ORX alarm status."
+ ::= { sleHFCEntry 24 }
+
+
+ sleHFCEDFA2LD1Current OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "HFC EDFA2 LD1 Current value."
+ ::= { sleHFCEntry 25 }
+
+
+ sleHFCEDFA2LD1CurrentAlarm OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ off(0),
+ on(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "HFC EDFA2 LD1 Current alarm status."
+ ::= { sleHFCEntry 26 }
+
+
+ sleHFCEDFA2LD2Current OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "HFC EDFA2 LD2 Current value."
+ ::= { sleHFCEntry 27 }
+
+
+ sleHFCEDFA2LD2CurrentAlarm OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ off(0),
+ on(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "HFC EDFA2 LD2 Current alarm status."
+ ::= { sleHFCEntry 28 }
+
+
+ sleHFCEDFA2LD1Temp OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "HFC EDFA2 LD1 Temp value."
+ ::= { sleHFCEntry 29 }
+
+
+ sleHFCEDFA2LD1TempAlarm OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ off(0),
+ on(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "HFC EDFA2 LD1 Temp alarm status."
+ ::= { sleHFCEntry 30 }
+
+
+ sleHFCEDFA2LD2Temp OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "HFC EDFA2 LD2 Temp value."
+ ::= { sleHFCEntry 31 }
+
+
+ sleHFCEDFA2LD2TempAlarm OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ off(0),
+ on(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "HFC EDFA2 LD2 Temp alarm status."
+ ::= { sleHFCEntry 32 }
+
+
+ sleHFCEDFA2CaseTemp OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "HFC EDFA2 Case Temp value."
+ ::= { sleHFCEntry 33 }
+
+
+ sleHFCEDFA2CaseTempAlarm OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ off(0),
+ on(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "HFC EDFA2 Case Temp alarm status."
+ ::= { sleHFCEntry 34 }
+
+
+ sleHFCControl OBJECT IDENTIFIER ::= { sleHFC 2 }
+
+
+ sleHFCControlRequest OBJECT-TYPE
+ SYNTAX INTEGER { setHFCAlarmStatus(1) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The request of a user command"
+ ::= { sleHFCControl 1 }
+
+
+ sleHFCControlStatus OBJECT-TYPE
+ SYNTAX SleControlStatusType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The status of user command"
+ ::= { sleHFCControl 2 }
+
+
+ sleHFCControlTimer OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The maximum time for the manager for a long running user command."
+ ::= { sleHFCControl 3 }
+
+
+ sleHFCControlTimeStamp OBJECT-TYPE
+ SYNTAX TimeTicks
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The time stamp of the last command(end of command)"
+ ::= { sleHFCControl 4 }
+
+
+ sleHFCControlReqResult OBJECT-TYPE
+ SYNTAX SleControlRequestResultType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The result of the last user command"
+ ::= { sleHFCControl 5 }
+
+
+ sleHFCControlAlarmIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ hfcefda1(0),
+ hfcefda2(1),
+ hfcoptic(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The HFC alarm index , edfa1 /edfa2 /optic ."
+ ::= { sleHFCControl 6 }
+
+
+ sleHFCControlAlarmStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ disable(0),
+ enable(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The HFC alrm status."
+ ::= { sleHFCControl 7 }
+
+
+ sleHFCNotification OBJECT IDENTIFIER ::= { sleHFC 3 }
+
+
+ sleHFCOpticAlarmStatusChanged NOTIFICATION-TYPE
+ OBJECTS { sleHFCControlRequest, sleHFCControlTimeStamp, sleHFCControlReqResult, sleHFCControlAlarmIndex, sleHFCControlAlarmStatus
+ }
+ STATUS current
+ DESCRIPTION
+ "HFC Alarm Status Changed."
+ ::= { sleHFCNotification 1 }
+
+
+ sleDeviceGroup OBJECT-GROUP
+ OBJECTS { sleRfConnectStatus, sleRfPortIndex, sleRfPortAdminStatus, sleRfPortOperStatus, sleDeviceEthernetPortNum,
+ sleDevicePowerNum, sleDeviceFanModuleNum, sleDeviceTemperatureNum, sleDeviceFanStartTemperature, sleDeviceFanStopTemperature,
+ sleDeviceControlRequest, sleDeviceControlStatus, sleDeviceControlTimer, sleDeviceControlTimeStamp, sleDeviceControlReqResult,
+ sleDeviceControlFanStartTemperature, sleDeviceControlFanStopTemperature, sleEthernetPortIndex, sleEthernetPortPhyIndex, sleEthernetPortType,
+ sleEthernetPortAdminStatus, sleEthernetPortOperStatus, sleEthernetPortTransmissionRate, sleEthernetPortDuplexMode, sleEthernetPortFlowControl,
+ sleEthernetPortNegotiationMode, sleEthernetPortJumboFrameSize, sleEthernetPortSfpTransceiver, sleEthernetPortSfpVendorName, sleEthernetPortSfpVendorPartNumber,
+ sleEthernetPortSfpVendorRevision, sleEthernetPortSfpVendorSerialNumber, sleEthernetPortSfpDateCode, sleEthernetPortPhysicalRemoteChassis, sleEthernetPortPhysicalRemoteSlot,
+ sleEthernetPortPhysicalRemotePort, sleEthernetPortPhysicalLinkDiscoveryMode, sleEthernetPortControlRequest, sleEthernetPortControlStatus, sleEthernetPortControlTimer,
+ sleEthernetPortControlTimeStamp, sleEthernetPortControlReqResult, sleEthernetPortControlIndex, sleEthernetPortControlType, sleEthernetPortControlAdminStatus,
+ sleEthernetPortControlTransmissionRate, sleEthernetPortControlDuplexMode, sleEthernetPortControlFlowControl, sleEthernetPortControlJumboFrameSize, sleEthernetPortControlPhysicalRemoteChassis,
+ sleEthernetPortControlPhysicalRemoteSlot, sleEthernetPortControlPhysicalRemotePort, sleEthernetPortControlPhysicalLinkDiscoveryMode, slePowerIndex, slePowerPhyIndex,
+ slePowerState, sleFanModuleIndex, sleFanModulePhyIndex, sleFanModuleUnitNum, sleFanModuleAdminState,
+ sleFanModuleControlRequest, sleFanModuleControlStatus, sleFanModuleControlTimer, sleFanModuleControlTimeStamp, sleFanModuleControlReqResult,
+ sleFanModuleControlIndex, sleFanModuleControlAdminState, sleFanUnitIndex, sleFanUnitOperState, sleTemperatureIndex,
+ sleTemperatureState, sleTemperatureValue, sleBatteryIndex, sleDoorStatus, sleOperationPowerType,
+ sleOperationPowerInfo, slePSUACPowerState, slePSUTemperture, slePSUOutVoltage, slePSUOverTemp,
+ slePSUFirmwareVer, sleRBUEquipState, sleRBUModeStaus, sleBatteryBackupFile, sleBatteryBackupControlRequest,
+ sleBatteryBackupControlStatus, sleBatteryBackupControlTimer, sleBatteryBackupControlTimeStamp, sleBatteryBackupControlReqResult, sleBatteryBackupControlServerIP,
+ sleBatteryBackupControlUserID, sleBatteryBackupControlPassword, sleBatteryBackupControlFlag, sleBatteryBackupControlLocalFile, sleBatteryBackupControlRemoteFile,
+ sleCpuProcessor, sleCpuModel, sleCpuRevision, sleCpuBogomips, sleCpuManufacturer,
+ sleCpuClock, sleCpuBusClock, sleRBUTemperature1, slePSUTempThreshold, sleRBUTemperature2,
+ sleRBUOutVoltage, sleRBUChargeCurrent, sleRBURemainCapacity, sleRBUOverTemp, sleBatteryLow,
+ sleRBUBTStatus, sleRBUBTThreshold, sleRBURechargeVoltage, sleBatteryCellStatus, sleBPSUACHardwareVer,
+ sleBatteryControlRequest, sleBatteryControlStatus, sleBatteryControlTimer, sleBatteryControlTimeStamp, sleBatteryControlReqResult,
+ sleBatteryControlRBUBTStatus, sleBatteryControlRBUBTThreshold, sleBatteryControlRBURechargeVoltage, sleBatteryControlTemperThresh1, sleBatteryControlTemperThresh2,
+ sleRBUTempHighThreshold, slePowerType, sleClockModuleIndex, sleClockModuleBoardId, sleClockModuleInstallStatus,
+ sleClockModuleInitStatus, sleSlotSystemIndex, sleSlotSystemUptime, sleSlotSystemModelName, sleSlotSystemSerialNumber,
+ sleSlotSystemHWVersion, sleSlotSystemBLVersion, sleSlotSystemSWCompatibility, sleSlotSystemOSVersion, sleSlotSystemMacAddress,
+ sleSlotSystemCPULoadAll, sleSlotSystemCPULoadInterrupt, sleSlotSystemMemoryTotal, sleSlotSystemMemoryFree, sleSlotSystemMemoryShared,
+ sleSlotSystemMemoryBuffers, sleSlotSystemMemoryCached, sleSlotSystemMemorySwapTotal, sleSlotSystemMemorySwapFree, sleSlotSystemBootReason,
+ sleSlotSystemBootTime, sleSlotSystemVoltage, sleSlotSystemControlRequest, sleSlotSystemControlStatus, sleSlotSystemControlTimer,
+ sleSlotSystemControlTimeStamp, sleSlotSystemControlReqResult, sleSlotSystemControlSlotIndex, sleSlotStatusPlan, sleSlotStatusPlanCardType,
+ sleSlotStatusCurrentInstall, sleSlotStatusCurrentInstallCardType, sleSlotStatusCardOperation, sleSlotStatusLock, sleSlotStatusUpgradeMode,
+ sleSlotStatusActionEvent, sleSlotStatusState, sleSlotStatusControlRequest, sleSlotStatusControlStatus, sleSlotStatusControlTimer,
+ sleSlotStatusControlTimeStamp, sleSlotStatusControlReqResult, sleSlotStatusControlSlotIndex, sleSlotStatusControlPlanCardType, sleSlotStatusControlUpgradeMode,
+ sleSlotNosVersion, sleSlotNosRevision, sleSlotNosSize, sleSlotNosUpgradeStatus, sleSlotNosControlRequest,
+ sleSlotNosControlStatus, sleSlotNosControlTimer, sleSlotNosControlTimeStamp, sleSlotNosControlReqResult, sleSlotNosControlSlotIndex,
+ sleSlotReleasedNIUNosVersion, sleSlotReleasedNIUNosRevision, sleSlotReleasedNIUNosSize, sleSlotReleasedGPIUNosVersion, sleSlotReleasedGPIUNosRevision,
+ sleSlotReleasedGPIUNosSize, sleSlotSystemPowerLevelStatus, sleSlotPowerMonStatus, sleSlotPowerMonVoltage, sleEthernetPortDMIIndex,
+ sleEthernetPortDMITemper, sleEthernetPortDMIVoltage, sleEthernetPortDMITxBias, sleEthernetPortDMITxPower, sleEthernetPortDMIRxPower,
+ sleEthernetPortSfpTransceiverType, sleSlotNosControlUpDownMethod, sleSlotNosControlUpDownFlag, sleSlotNosControlServerAddress, sleSlotNosControlUserID,
+ sleSlotNosControlPassword, sleSlotNosControlFileName, sleFanUnitSpeed, sleSlotSystemInfoLEDStatus, sleFanModuleSpeedThreshold,
+ sleFanModuleControlSpeedThreshold, sleEthernetPortSfpTransceiverDetailType, sleClockModuleOPMode, sleClockInfoInSrcType, sleClockInfoInSrcAISStatus,
+ sleClockInfoInSrcLoSStatus, sleClockInfoInSrcLDSCStatus, sleClockInfoInSrcNtrClockType, sleDeviceJumboFrameStatus, sleDeviceControlJumboFrameStatus,
+ slePowerPSUType, sleSlotSystemInfoPackageVersion, sleEthernetSfpIndex, sleEthernetSfpTransceiver, sleEthernetSfpVendorName,
+ sleEthernetSfpVendorPartNumber, sleEthernetSfpDateCode, sleEthernetSfpTransceiverType, sleEthernetSfpTransceiverDetailType, sleTemperatureHighThreshold,
+ sleTemperatureLowThreshold, sleTemperatureControlRequest, sleTemperatureControlStatus, sleTemperatureControlTimer, sleTemperatureControlTimeStamp,
+ sleTemperatureControlReqResult, sleTemperatureControlIndex, sleTemperatureControlHighThreshold, sleTemperatureControlLowThreshold, sleEthernetSFPControlRequest,
+ sleEthernetSFPControlStatus, sleEthernetSFPControlTimer, sleEthernetSFPControlTimeStamp, sleEthernetSFPControlReqResult, sleEthernetSFPControlIndex,
+ sleTemperatureWarnHighThreshold, sleTemperatureWarnLowThreshold, sleTemperatureWarnDuration, sleTemperatureAlarmHighThreshold, sleTemperatureAlarmLowThreshold,
+ sleTemperatureAlarmDuration, sleTemperatureControlDuration, sleSlotPowerMonIndex, sleEthernetPortSlotIndex, sleEthernetPortSlotPortIndex,
+ sleEthernetSfpVendorRevision, sleEthernetSfpVendorSerialNumber, sleEthernetSfpTransceiverCodes, sleSlotNosStbVersion, sleSlotNosStbRevision,
+ sleSlotNosStbSize, sleDeviceEnvironmentMonitoringStatus, sleDeviceControlEnvironmentMonitoringStatus, sleRfPowerStatus, sleSlotAiuRunStatus,
+ sleSlotAiuAlarmStatus, sleEthernetPortAdminTransmissionRate, sleEthernetPortAdminDuplexMode, sleEthernetPortAdminFlowControl, sleEthernetPortAdminNegotiationMode,
+ sleSlotReleasedSIUNosVersion, sleSlotReleasedSIUNosRevision, sleSlotReleasedSIUNosSize, sleEMInputIndex, sleEMAlarmString,
+ sleEMAlarmSeverity, sleEMmode, sleEMControlRequest, sleEMControlStatus, sleEMControlInputIndex,
+ sleEMControlAlarmString, sleEMControlAlarmSeverity, sleEMControlmode, sleEthernetSfpSpeed, sleEthernetSfpLength,
+ sleEthernetSfpWaveLength, sleRfEthertype, sleRfSrcAddress, sleRfDesAddress, sleRBUTempLowThreshold,
+ sleEthernetPortControlNegotiationMode, sleSlotStatusPower, sleSlotStatusSerialNumber, sleEMControlTimer, sleEMControlTimeStamp,
+ sleEthernetPortAdminReason, sleEMControlReqResult, sleRfBaseControlRequest, sleRfBaseControlStatus, sleRfBaseControlTimer,
+ sleRfBaseControlTimeStamp, sleRfBaseControlReqResult, sleRfBaseControlRfEthertype, sleRfPortControlRequest, sleRfPortControlStatus,
+ sleRfPortControlTimer, sleRfPortControlTimeStamp, sleRfPortControlReqResult, sleRfPortControlIndex, sleBypassMode,
+ sleBypassStatus, sleBypassBaseControlRequest, sleBypassBaseControlStatus, sleBypassBaseControlTimer, sleBypassBaseControlTimeStamp,
+ sleBypassBaseControlReqResult, sleBypassBaseControlMode, sleBypassOptionConnectivityAddress, sleBypassOptionConnectivityPort, sleBypassOptionConnectivityControlRequest,
+ sleBypassOptionConnectivityControlStatus, sleBypassOptionConnectivityControlTimer, sleBypassOptionConnectivityControlTimeStamp, sleBypassOptionConnectivityControlReqResult, sleBypassOptionConnectivityControlAddress,
+ sleBypassOptionConnectivityControlPort, sleBypassOptionPingAddress, sleBypassOptionPingTransInterval, sleBypassOptionPingTranNumber, sleBypassOptionPingReqInterval,
+ sleBypassOptionPingReqTimeout, sleBypassOptionPingLossThresh, sleBypassOptionPingControlRequest, sleBypassOptionPingControlStatus, sleBypassOptionPingControlTimer,
+ sleBypassOptionPingControlTimeStamp, sleBypassOptionPingControlReqResult, sleBypassOptionPingControlAddress, sleBypassOptionPingControlTransInterval, sleBypassOptionPingControlTranNumber,
+ sleBypassOptionPingControlReqInterval, sleBypassOptionPingControlReqTimeout, sleBypassOptionPingControlLossThresh, sleBypassOptionLinkMonitorPort, sleBypassOptionLinkMonitorPortStatus,
+ sleBypassOptionLinkMonitorControlRequest, sleBypassOptionLinkMonitorControlStatus, sleBypassOptionLinkMonitorControlTimer, sleBypassOptionLinkMonitorControlTimeStamp, sleBypassOptionLinkMonitorControlReqResult,
+ sleBypassOptionLinkMonitorControlPort, sleBypassOptionLinkMonitorControlPortStatus, sleSlotSystemInfoManufacturer, sleSlotSystemInfoManufactureDate, sleSlotStatusHealthState,
+ sleRfPortControlAdminStatus, sleClockInfoInSrcStatus, sleEthernetSfpMultimodeLengthOm1, sleEthernetSfpMultimodeLengthOm2, sleEthernetSfpTransceiverDetailTypeStr,
+ sleEthernetSfpTransceiverLengthStr, sleEthernetSfpWaveLengthStr, sleEthernetSfpConnectorType, sleSlotReleasedIU10GE8NosVersion, sleSlotReleasedIU10GE8NosRevision,
+ sleSlotReleasedIU10GE8NosSize, sleSlotReleasedIU10GEPON8NosVersion, sleSlotReleasedIU10GEPON8NosRevision, sleSlotReleasedIU10GEPON8NosSize, sleSlotReleasedIUGEPON8NosVersion,
+ sleSlotReleasedIUGEPON8NosRevision, sleSlotReleasedIUGEPON8NosSize, sleEthernetSfpMultimodeLengthOm3, sleSlotProtectionSystemStatus, sleSlotProtectionSystemThreshold,
+ sleSlotProtectionControlRequest, sleSlotProtectionControlStatus, sleSlotProtectionControlTimer, sleSlotProtectionControlTimeStamp, sleSlotProtectionControlReqResult,
+ sleSlotProtectionControlSystemStatus, sleSlotProtectionControlSystemThreshold, sleSlotProtectionIUControlRequest, sleSlotProtectionIUControlStatus, sleSlotProtectionIUControlTimer,
+ sleSlotProtectionIUControlTimeStamp, sleSlotProtectionIUControlReqResult, sleSlotProtectionIUControlTemperHighThresh, sleSlotProtectionIUControlTemperLowThresh, sleSlotProtectionIUControlPowerThresh,
+ sleSlotProtectionIUTemperHighThresh, sleSlotProtectionIUTemperLowThresh, sleSlotProtectionIUPowerStatus, sleSlotProtectionIUPowerThresh, sleSlotProtectionIUTemper,
+ sleHFCOptic1550OTX, sleHFCOptic1550OTXAlarm, sleHFCOpticUpstreamOTX, sleHFCOpticUpstreamOTXAlarm, sleHFCOpticDownstreamORX,
+ sleHFCOpticDownstreamORXAlarm, sleHFCEDFA1OTX, sleHFCEDFA1OTXAlarm, sleHFCEDFA1ORX, sleHFCEDFA1ORXAlarm,
+ sleHFCEDFA1LD1Current, sleHFCEDFA1LD1CurrentAlarm, sleHFCEDFA1LD2Current, sleHFCEDFA1LD2CurrentAlarm, sleHFCEDFA1LD1Temp,
+ sleHFCEDFA1LD1TempAlarm, sleHFCEDFA1LD2Temp, sleHFCEDFA1LD2TempAlarm, sleHFCEDFA1CaseTemp, sleHFCEDFA1CaseTempAlarm,
+ sleHFCEDFA2OTX, sleHFCEDFA2OTXAarm, sleHFCEDFA2ORX, sleHFCEDFA2ORXAlarm, sleHFCEDFA2LD1Current,
+ sleHFCEDFA2LD1CurrentAlarm, sleHFCEDFA2LD2Current, sleHFCEDFA2LD2CurrentAlarm, sleHFCEDFA2LD1Temp, sleHFCEDFA2LD1TempAlarm,
+ sleHFCEDFA2LD2Temp, sleHFCEDFA2LD2TempAlarm, sleHFCEDFA2CaseTemp, sleHFCEDFA2CaseTempAlarm, sleHFCControlRequest,
+ sleHFCControlStatus, sleHFCControlTimer, sleHFCControlTimeStamp, sleHFCControlReqResult, sleHFCControlAlarmIndex,
+ sleHFCControlAlarmStatus, sleSlotSystemCPULoadHighThreshold, sleSlotSystemCPULoadHighThresholdTimer, sleSlotSystemCPULoadLowThreshold, sleSlotSystemCPULoadLowThresholdTimer,
+ sleSlotProtectionIUControlindex, sleSlotSystemCPULoadCurrent, sleEthernetPortLinkCheckTimer, sleEthernetPortLinkDebounceTime, sleEthernetPortCpuStatisticsLimitUnicast,
+ sleEthernetPortCpuStatisticsLimitMulticast, sleEthernetPortCpuStatisticsLimitBroadcast, sleEthernetPortFloodBlockBroadcastState, sleEthernetPortFloodBlockDlfState, sleEthernetPortControlLinkCheckTimer,
+ sleEthernetPortControlLinkDebounceTime, sleEthernetPortControlCpuStatisticsLimitUnicast, sleEthernetPortControlCpuStatisticsLimitMulticast, sleEthernetPortControlCpuStatisticsLimitBroadcast, sleEthernetPortControlFloodBlockBroadcastState,
+ sleEthernetPortControlFloodBlockDlfState, sleEthernetSfpDdmState, sleEthernetSfpNegoState, sleEthernetSfpControlDdmState, sleEthernetSFPThresholdIfIndex,
+ sleEthernetSFPThresholdType, sleEthernetSFPThresholdSfpLow, sleEthernetSFPThresholdSfpHigh, sleEthernetSFPThresholdSystemLow, sleEthernetSFPThresholdSystemHigh,
+ sleEthernetSFPThresholdControlRequest, sleEthernetSFPThresholdControlStatus, sleEthernetSFPThresholdControlTimer, sleEthernetSFPThresholdControlTimeStamp, sleEthernetSFPThresholdControlReqResult,
+ sleEthernetSFPThresholdControlIfIndex, sleEthernetSFPThresholdControlType, sleEthernetSFPThresholdControlSfpLow, sleEthernetSFPThresholdControlSfpHigh, sleEthernetSFPThresholdControlSystemLow,
+ sleEthernetSFPThresholdControlSystemHigh, sleSlotSystemCPUOverallStatus, sleSlotSystemTemperOverallStatus, sleslotStatusOverallState, sleslotStatusSyncState,
+ sleSlotProtectionIUTemper2, sleSlotProtectionControlIUPowerStatus, sleSlotSystemControlCPULoadHighThreshold, sleSlotSystemControlCPULoadHighThresholdTimer, sleSlotSystemControlCPULoadLowThreshold,
+ sleSlotSystemControlCPULoadLowThresholdTimer }
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleDevice 16 }
+
+
+ sleDeviceNotificationGroup NOTIFICATION-GROUP
+ NOTIFICATIONS { sleDeviceTemperatureThresholdChanged, sleEthernetPortChanged, sleFanAdminStateChanged, sleBatteryBackupProfileChanged, sleBatteryBackupUpgraded,
+ sleSlotSystemRestart, sleSlotStatusLocked, sleSlotStatusUnlocked, sleSlotStatusPlanning, sleSlotStatusNoPlanning,
+ sleSlotStatusUpgradeModeChanged, sleSlotNosUpgrade, sleSlotStatusPowerUp, sleSlotStatusPowerDown, sleSlotStatusPowerReset,
+ sleSlotNosDownload, sleSlotNosBootloaderUpgrade, sleFanSpeedThresholdChanged, sleDeviceJumboFrameChanged, sleTemperatureThresholdChanged,
+ sleDeviceLEDTestChanged, sleEthernetSFPRemoteReset, sleRfPortStatusChanged, sleDeviceEnvironmentMonitoringStatusChanged, sleEMChanged,
+ sleEMDeleted, sleRFBaseEthertypeChanged, sleRFBaseEthertypeResetChanged, sleBypassModeChanged, sleBypassOptionConnectivitySet,
+ sleBypassOptionConnectivityUnset, sleBypassOptionPingSet, sleBypassOptionPingUnset, sleBypassOptionLinkMonitorChanged, sleSlotProtectionSystemStatusChanged,
+ sleSlotProtectionSystemThreshChanged, sleSlotProtectionIUTemperThreshChanged, sleSlotProtectionIUPowerThreshChanged, sleSlotProtectionIUPowerStatusChanged, sleHFCOpticAlarmStatusChanged,
+ sleSlotSystemCPULoadChagned, sleSlotSystemCPULoadDeleted, sleEthernetPortLinkChanged, sleEthernetPortCpuStatisticsLimitChanged, sleEthernetPortFloodBlockStateChanged,
+ sleEthernetSFPDdmState, sleEthernetSFPThresholdSfpChanged, sleEthernetSFPThresholdSystemChanged, sleEthernetSFPThresholdDestroyed, sleBatteryBackupTableCleared,
+ sleBatteryForceChargeChanged, sleBatteryChargingStartChanged, sleBatteryForceChargeNonStopChanged, sleBatteryRBUBTStatusChanged, sleBatteryRBUBTThresholdChanged,
+ sleBatteryRBURechargeVoltageChanged, sleBatteryPsuAcTemperThreshChanged, sleBatteryRBUTemperThreshChanged }
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleDevice 17 }
+
+
+
+ END
+
+--
+-- SLE-DEVICE-MIB.my
+--
|