summaryrefslogtreecommitdiff
path: root/MIBS/dell/DELL-RAC-MIB
diff options
context:
space:
mode:
authorDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
committerDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
commit98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch)
tree9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/dell/DELL-RAC-MIB
downloadmibs-main.tar.gz
mibs-main.zip
Initial commitHEADmain
Diffstat (limited to 'MIBS/dell/DELL-RAC-MIB')
-rw-r--r--MIBS/dell/DELL-RAC-MIB7229
1 files changed, 7229 insertions, 0 deletions
diff --git a/MIBS/dell/DELL-RAC-MIB b/MIBS/dell/DELL-RAC-MIB
new file mode 100644
index 0000000..dd2f031
--- /dev/null
+++ b/MIBS/dell/DELL-RAC-MIB
@@ -0,0 +1,7229 @@
+--
+-- Dell Remote Access Controller (RAC) and Chassis Management Controller (CMC)
+-- Management Information Base
+--
+-- This MIB is the legacy iDRAC MIB. Changes are no longer made to this MIB
+-- for iDRACs. iDRACs don't support all of the objects and traps defined
+-- in this MIB. There is a new and more extensive iDRAC MIB available for
+-- newer iDRACs (iDRAC7 and newer).
+--
+-- This MIB is also the CMC MIB. Changes are made to this MIB only for CMCs now.
+--
+-- Copyright (c) 2017 Dell Inc.
+--
+-- Last Changed Revision: 19
+-- Last Changed Date: 2017-07-13 03:46:06 -0530 (Thu, 13 Jul 2017)
+-- Text Last Updated: 2017-07-13 03:46:06 -0530 (Thu, 13 Jul 2017)
+--
+
+DELL-RAC-MIB DEFINITIONS ::= BEGIN
+
+IMPORTS
+ enterprises, TimeTicks
+ FROM RFC1155-SMI
+ OBJECT-TYPE
+ FROM RFC-1212
+ TRAP-TYPE
+ FROM RFC-1215
+ DisplayString
+ FROM RFC1213-MIB;
+
+-- text convention ------------------------------------------------------------------------
+
+ -------------------------------------------------------------------------------
+ -- This data type is used to model textual information taken
+ -- from the NVT ASCII character set. By convention, objects
+ -- with this syntax are declared as having
+ -- SIZE (0..1023)
+ -------------------------------------------------------------------------------
+ DellString ::= DisplayString (SIZE (0..1023))
+
+ DellRacType ::= INTEGER
+ {
+ other(1), -- the DRAC type is not one of the following
+ unknown(2), -- the DRAC type is unknown
+ dracIII(3), -- Drac III
+ era(4), -- ERA
+ drac4(5), -- Drac 4
+ drac5(6), -- Drac 5
+ drac5MC(7), -- Drac 5/MC
+ cmc(8), -- CMC
+ idrac(9), -- iDRAC
+ idrac7monolithic(16), -- iDRAC7 Monolithic
+ idrac7modular(17), -- iDRAC7 Modular
+ vrtxCMC(18), -- VRTX CMC
+ fx2CMC(19), -- FX2 Family CMC
+ idrac8monolithic(32), -- iDRAC8 Monolithic
+ idrac8modular(33) -- iDRAC8 Modular
+ }
+
+ DellStatus ::= INTEGER
+ {
+ other(1), -- the status of the object is not one of the following:
+ unknown(2), -- the status of the object is unknown
+ -- (not known or monitored)
+ ok(3), -- the status of the object is ok
+ nonCritical(4), -- the status of the object is warning, non-critical
+ critical(5), -- the status of the object is critical (failure)
+ nonRecoverable(6) -- the status of the object is non-recoverable (dead)
+ }
+
+ -------------------------------------------------------------------------------
+ -- DellPowerReading is a string representation of a floating point value,
+ -- having exactly 3 digits of precision, and a maximum of 31 characters.
+ --
+ -- DellChassisPowerIndexRange defines the possible chassis power instances
+ -- in this MIB.
+ --
+ -- DellCMCPSUIndexRange defines the possible CMC Power Supply Unit (PSU)
+ -- instances, per chassis power instance, in this MIB.
+ --
+ -- DellCMCPSUCapable is an enumeration of PSU presence and/or monitoring
+ -- capabilities.
+ --
+ -- DellTemperatureReading is an integer value, expressed in degrees Celsius.
+ -------------------------------------------------------------------------------
+ DellPowerReading ::= DisplayString (SIZE (0..32))
+
+ DellCMCPowerIndexRange ::= INTEGER (1..1)
+
+ DellCMCPSUIndexRange ::= INTEGER (1..6)
+
+ DellCMCPSUCapable ::= INTEGER
+ {
+ absent(1), -- power supply is not present
+ none(2), -- no power monitoring abilities
+ basic(3) -- basic power monitoring abilities
+ }
+
+ DellTemperatureReading ::= INTEGER
+
+ -------------------------------------------------------------------------------
+ -- DellTimestamp is defined in the displayable format:
+ --
+ -- yyyymmddHHMMSS.uuuuuuDooo
+ --
+ -- where yyyy is the year, mm is the month number, dd is the day of the month,
+ -- HHMMSS are the hours, minutes and seconds, respectively, uuuuuu is the
+ -- number of microseconds, D is the UTC offset direction, and ooo is the
+ -- offset from UTC, in minutes.
+ --
+ -- Note: D is a plus (+) sign if east of UTC, and a minus (-) if west of UTC.
+ --
+ -- For example, Wednesday, May 25, 1994, at 1:30:15 PM EDT
+ -- would be represented as: 19940525133015.000000-300
+ -------------------------------------------------------------------------------
+ DellTimestamp ::= DisplayString (SIZE (26))
+
+ -------------------------------------------------------------------------------
+ -- DellCMCServerIndexRange defines the possible chassis server instances
+ -- in this MIB.
+ --
+ -- DellCMCServerCapable is an enumeration of server presence and/or monitoring
+ -- capabilities.
+ -------------------------------------------------------------------------------
+ DellCMCServerIndexRange ::= INTEGER (1..32)
+
+ DellCMCServerCapable ::= INTEGER
+ {
+ absent(1), -- server is not present
+ none(2), -- no server monitoring abilities
+ basic(3), -- basic server monitoring abilities
+ off(4) -- server is powered off
+ }
+
+ DellCMCServerStorageMode ::= INTEGER
+ {
+ notApplicable(1), -- not applicable to server
+ joined(2), -- storage mode is Joined
+ splitDualHost(3), -- storage mode is Split Dual Host
+ splitSingleHost(4), -- storage mode is Split Single Host
+ unknown(99) -- storage mode is unknown
+ }
+
+ DellCMCServerIntrusionState ::= INTEGER
+ {
+ notApplicable(1), -- not applicable to server
+ closed(2), -- intrusion state is Closed
+ open(3), -- intrusion state is Open
+ unknown(99) -- intrusion state is unknown
+ }
+
+
+-- MIB Objects and Tables --------------------------------------------------------
+
+ dell OBJECT IDENTIFIER ::= { enterprises 674 }
+ server3 OBJECT IDENTIFIER ::= { dell 10892 }
+ drsOutofBandGroup OBJECT IDENTIFIER ::= { server3 2 }
+ drsInformationGroup OBJECT IDENTIFIER ::= { drsOutofBandGroup 1 }
+ drsProductInfoGroup OBJECT IDENTIFIER ::= { drsInformationGroup 1 }
+ drsFirmwareGroup OBJECT IDENTIFIER ::= { drsInformationGroup 2 }
+
+ drsStatusGroup OBJECT IDENTIFIER ::= { drsOutofBandGroup 2 }
+
+ drsChassisStatusGroup OBJECT IDENTIFIER ::= { drsOutofBandGroup 3 }
+ drsStatusNowGroup OBJECT IDENTIFIER ::= { drsChassisStatusGroup 1 }
+ drsStatusPrevGroup OBJECT IDENTIFIER ::= { drsChassisStatusGroup 2 }
+ drsStatusChangeGroup OBJECT IDENTIFIER ::= { drsChassisStatusGroup 3 }
+
+ drsChassisPowerGroup OBJECT IDENTIFIER ::= { drsOutofBandGroup 4 }
+
+ DrsCMCPowerTableEntry ::= SEQUENCE
+ {
+ drsChassisIndex DellCMCPowerIndexRange,
+ drsPotentialPower DellPowerReading,
+ drsIdlePower DellPowerReading,
+ drsMaxPowerSpecification DellPowerReading,
+ drsPowerSurplus DellPowerReading,
+ drsKWhCumulative DellPowerReading,
+ drsKWhCumulativeTime DellTimestamp,
+ drsWattsPeakUsage DellPowerReading,
+ drsWattsPeakTime DellTimestamp,
+ drsWattsMinUsage DellPowerReading,
+ drsWattsMinTime DellTimestamp,
+ drsWattsResetTime DellTimestamp,
+ drsWattsReading DellPowerReading,
+ drsAmpsReading DellPowerReading
+ }
+
+ DrsCMCPSUTableEntry ::= SEQUENCE
+ {
+ drsPSUChassisIndex DellCMCPowerIndexRange,
+ drsPSUIndex DellCMCPSUIndexRange,
+ drsPSULocation DellString,
+ drsPSUMonitoringCapable DellCMCPSUCapable,
+ drsPSUVoltsReading DellPowerReading,
+ drsPSUAmpsReading DellPowerReading,
+ drsPSUWattsReading DellPowerReading
+ }
+
+ drsChassisServerGroup OBJECT IDENTIFIER ::= { drsOutofBandGroup 5 }
+
+ DrsCMCServerTableEntry ::= SEQUENCE
+ {
+ drsServerIndex DellCMCServerIndexRange,
+ drsServerMonitoringCapable DellCMCServerCapable,
+ drsServerServiceTag DellString,
+ drsServerSlotName DellString,
+ drsServerSlotNumber DellString,
+ drsServerNodeID DellString,
+ drsServerModel DellString,
+ drsServerAssetTag DellString,
+ drsServerNumStorageControllers INTEGER,
+ drsServerStorageMode DellCMCServerStorageMode,
+ drsServerIntrusionState DellCMCServerIntrusionState,
+ drsServerAssignedServerSlots DellString
+ }
+
+-- Storage details start
+storageDetailsGroup OBJECT IDENTIFIER ::= { drsOutofBandGroup 6 }
+software OBJECT IDENTIFIER ::= { storageDetailsGroup 1 }
+storageManagement OBJECT IDENTIFIER ::= { software 20 }
+physicalDevices OBJECT IDENTIFIER ::= { storageManagement 130 }
+logicalDevices OBJECT IDENTIFIER ::= { storageManagement 140 }
+
+
+------------------------------------------------------------------------------
+-- Textual Conventions
+------------------------------------------------------------------------------
+
+FQDDString ::= DisplayString (SIZE (0..512))
+
+ObjectStatusEnum ::= INTEGER {
+ other(1), -- the status of the object is not one of the
+ -- following:
+ unknown(2), -- the status of the object is unknown
+ -- (not known or monitored)
+ ok(3), -- the status of the object is ok
+ nonCritical(4), -- the status of the object is warning, non-critical
+ critical(5), -- the status of the object is critical (failure)
+ nonRecoverable(6) -- the status of the object is non-recoverable (dead)
+}
+BooleanType ::= INTEGER (0..1) -- 0 = FALSE, 1 = TRUE
+
+
+-- Storage details end
+
+
+ drsCMCAlertGroup OBJECT IDENTIFIER ::= { drsOutofBandGroup 20 }
+ drsChassisAlertVariables OBJECT IDENTIFIER ::= { drsCMCAlertGroup 10 }
+ drsCMCAlert2Group OBJECT IDENTIFIER ::= { drsOutofBandGroup 21 }
+ drsChassisAlert2Variables OBJECT IDENTIFIER ::= { drsCMCAlert2Group 10 }
+
+ drsAlertGroup OBJECT IDENTIFIER ::= { drsOutofBandGroup 5000 }
+ drsAlertVariables OBJECT IDENTIFIER ::= { drsAlertGroup 10 }
+
+
+-- Variables and Traps ------------------------------------------------------------------------
+
+ -------------------------------------------------------------------------------
+ -- group: product information
+ -------------------------------------------------------------------------------
+
+ drsProductName OBJECT-TYPE
+ SYNTAX DellString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0001.0001.0001 This attribute defines the product name of a chassis management controller."
+ ::= { drsProductInfoGroup 1 }
+
+ drsProductShortName OBJECT-TYPE
+ SYNTAX DellString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0001.0001.0002 This attribute defines the short product name of a chassis management controller. "
+ ::= { drsProductInfoGroup 2 }
+
+ drsProductDescription OBJECT-TYPE
+ SYNTAX DellString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0001.0001.0003 This attribute defines the product description of a chassis management controller. "
+ ::= { drsProductInfoGroup 3 }
+
+ drsProductManufacturer OBJECT-TYPE
+ SYNTAX DellString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0001.0001.0004 This attribute defines the product manufacturer of a chassis management controller. "
+ ::= { drsProductInfoGroup 4 }
+
+ drsProductVersion OBJECT-TYPE
+ SYNTAX DellString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0001.0001.0005 This attribute defines the product version of a chassis management controller. "
+ ::= { drsProductInfoGroup 5 }
+
+ drsChassisServiceTag OBJECT-TYPE
+ SYNTAX DellString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0001.0001.0007 This attribute defines the Service Tag of the chassis. "
+ ::= { drsProductInfoGroup 6 }
+
+ drsProductURL OBJECT-TYPE
+ SYNTAX DellString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0001.0001.0006 This attribute defines the out-of-band UI URL of a chassis management controller. "
+ ::= { drsProductInfoGroup 7 }
+
+ drsProductChassisAssetTag OBJECT-TYPE
+ SYNTAX DellString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0001.0001.0008 This attribute defines the Asset Tag of the chassis. "
+ ::= { drsProductInfoGroup 8 }
+
+ drsProductChassisLocation OBJECT-TYPE
+ SYNTAX DellString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0001.0001.0009 This attribute defines the location of the chassis. "
+ ::= { drsProductInfoGroup 9 }
+
+ drsProductChassisName OBJECT-TYPE
+ SYNTAX DellString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0001.0001.0010 This attribute defines the name of the chassis. "
+ ::= { drsProductInfoGroup 10 }
+
+ drsSystemServiceTag OBJECT-TYPE
+ SYNTAX DellString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0001.0001.0011 This attribute defines the service tag of a system. "
+ ::= { drsProductInfoGroup 11 }
+
+ drsProductSystemAssetTag OBJECT-TYPE
+ SYNTAX DellString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0001.0001.0012 This attribute defines the asset tag of a system. "
+ ::= { drsProductInfoGroup 12 }
+
+ drsProductSystemSlot OBJECT-TYPE
+ SYNTAX DellString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0001.0001.0013 This attribute defines the slot number of a CMC. "
+ ::= { drsProductInfoGroup 13 }
+
+ drsProductType OBJECT-TYPE
+ SYNTAX DellRacType
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0001.0001.0014 This attribute defines type of a remote access card "
+ ::= { drsProductInfoGroup 14 }
+
+ drsProductChassisDataCenter OBJECT-TYPE
+ SYNTAX DellString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0001.0001.0015 This attribute defines the Data Center locator of the chassis. "
+ ::= { drsProductInfoGroup 15 }
+
+ drsProductChassisAisle OBJECT-TYPE
+ SYNTAX DellString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0001.0001.0016 This attribute defines the Aisle locator of the chassis. "
+ ::= { drsProductInfoGroup 16 }
+
+ drsProductChassisRack OBJECT-TYPE
+ SYNTAX DellString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0001.0001.0017 This attribute defines the Rack locator of the chassis. "
+ ::= { drsProductInfoGroup 17 }
+
+ drsProductChassisRackSlot OBJECT-TYPE
+ SYNTAX DellString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0001.0001.0018 This attribute defines the Rack Slot locator of the chassis. "
+ ::= { drsProductInfoGroup 18 }
+
+ drsProductChassisModel OBJECT-TYPE
+ SYNTAX DellString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0001.0001.0019 This attribute defines the Model of the chassis."
+ ::= { drsProductInfoGroup 19 }
+
+ drsProductChassisExpressServiceCode OBJECT-TYPE
+ SYNTAX DellString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0001.0001.0020 This attribute defines the Express Service Code of the chassis."
+ ::= { drsProductInfoGroup 20 }
+
+ drsProductChassisSystemID OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0001.0001.0021 This attribute defines the System ID of the chassis."
+ ::= { drsProductInfoGroup 21 }
+
+ drsProductChassisSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0001.0001.0022 This attribute defines the size of the
+ chassis in rack units (U). A U is a standard unit of
+ measure for the height of a rack or rack-mountable component."
+ ::= { drsProductInfoGroup 22 }
+
+ -------------------------------------------------------------------------------
+ -- group: firmware
+ -------------------------------------------------------------------------------
+
+ drsFirmwareVersion OBJECT-TYPE
+ SYNTAX DellString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0001.0002.0001 This attribute defines the firmware version of chassis management controller 1."
+ ::= { drsFirmwareGroup 1 }
+
+ drsiKVMFirmwareVersion OBJECT-TYPE
+ SYNTAX DellString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0001.0002.0002 This attribute defines the firmware version of the iKVM. "
+ ::= { drsFirmwareGroup 2 }
+
+ drsFirmwareVersion2 OBJECT-TYPE
+ SYNTAX DellString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0001.0002.0003 This attribute defines the firmware version of chassis management controller 2."
+ ::= { drsFirmwareGroup 3 }
+
+ -------------------------------------------------------------------------------
+ -- group: chassis status
+ -------------------------------------------------------------------------------
+
+ drsGlobalSystemStatus OBJECT-TYPE
+ SYNTAX DellStatus
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0002.0001.0001 This attribute defines the overall chassis status
+ being monitored by the chassis management card."
+ ::= { drsStatusGroup 1 }
+
+ drsGlobalCurrStatus OBJECT-TYPE
+ SYNTAX DellStatus
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0003.0001.0001 This attribute defines the overall chassis status
+ being monitored by the chassis management card."
+ ::= { drsStatusNowGroup 1 }
+
+ drsIOMCurrStatus OBJECT-TYPE
+ SYNTAX DellStatus
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0003.0001.0002 This attribute defines the IOM subsystem status
+ being monitored by the chassis management card."
+ ::= { drsStatusNowGroup 2 }
+
+ drsKVMCurrStatus OBJECT-TYPE
+ SYNTAX DellStatus
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0003.0001.0003 This attribute defines the iKVM subsystem health status
+ being monitored by the chassis management card."
+ ::= { drsStatusNowGroup 3 }
+
+ drsRedCurrStatus OBJECT-TYPE
+ SYNTAX DellStatus
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0003.0001.0004 This attribute defines the Redundancy status
+ being monitored by the chassis management card."
+ ::= { drsStatusNowGroup 4 }
+
+ drsPowerCurrStatus OBJECT-TYPE
+ SYNTAX DellStatus
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0003.0001.0005 This attribute defines the power subsystem health status
+ being monitored by the chassis management card."
+ ::= { drsStatusNowGroup 5 }
+
+ drsFanCurrStatus OBJECT-TYPE
+ SYNTAX DellStatus
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0003.0001.0006 This attribute defines the Fan subsystem health status
+ being monitored by the chassis management card."
+ ::= { drsStatusNowGroup 6 }
+
+ drsBladeCurrStatus OBJECT-TYPE
+ SYNTAX DellStatus
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0003.0001.0007 This attribute defines the Blade subsystem health status
+ being monitored by the chassis management card."
+ ::= { drsStatusNowGroup 7 }
+
+ drsTempCurrStatus OBJECT-TYPE
+ SYNTAX DellStatus
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0003.0001.0008 This attribute defines the Temp Sensor subsystem health status
+ being monitored by the chassis management card."
+ ::= { drsStatusNowGroup 8 }
+
+ drsCMCCurrStatus OBJECT-TYPE
+ SYNTAX DellStatus
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0003.0001.0009 This attribute defines the CMC health status
+ being monitored by the chassis management card."
+ ::= { drsStatusNowGroup 9 }
+
+ drsChassisFrontPanelAmbientTemperature OBJECT-TYPE
+ SYNTAX DellTemperatureReading
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0003.0001.0010 This attribute defines the ambient temperature
+ reading (in degrees Celsius) for the chassis front panel controller."
+ ::= { drsStatusNowGroup 10 }
+
+ drsCMCAmbientTemperature OBJECT-TYPE
+ SYNTAX DellTemperatureReading
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0003.0001.0011 This attribute defines the ambient temperature
+ reading (in degrees Celsius) for the chassis management card."
+ ::= { drsStatusNowGroup 11 }
+
+ drsCMCProcessorTemperature OBJECT-TYPE
+ SYNTAX DellTemperatureReading
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0003.0001.0012 This attribute defines the temperature reading
+ (in degrees Celsius) for the chassis management card processor."
+ ::= { drsStatusNowGroup 12 }
+
+ drsGlobalPrevStatus OBJECT-TYPE
+ SYNTAX DellStatus
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0003.0002.0001 This attribute defines the previous chassis status
+ recorded by the chassis management card."
+ ::= { drsStatusPrevGroup 1 }
+
+ drsIOMPrevStatus OBJECT-TYPE
+ SYNTAX DellStatus
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0003.0002.0002 This attribute defines the previous IOM subsystem status
+ recorded by the chassis management card."
+ ::= { drsStatusPrevGroup 2 }
+
+ drsKVMPrevStatus OBJECT-TYPE
+ SYNTAX DellStatus
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0003.0002.0003 This attribute defines the previous iKVM subsystem health status
+ recorded by the chassis management card."
+ ::= { drsStatusPrevGroup 3 }
+
+ drsRedPrevStatus OBJECT-TYPE
+ SYNTAX DellStatus
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0003.0002.0004 This attribute defines the previous Redundancy status
+ recorded by the chassis management card."
+ ::= { drsStatusPrevGroup 4 }
+
+ drsPowerPrevStatus OBJECT-TYPE
+ SYNTAX DellStatus
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0003.0002.0005 This attribute defines the previous power subsystem health status
+ recorded by the chassis management card."
+ ::= { drsStatusPrevGroup 5 }
+
+ drsFanPrevStatus OBJECT-TYPE
+ SYNTAX DellStatus
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0003.0002.0006 This attribute defines the previous Fan health status
+ being monitored by the chassis management card."
+ ::= { drsStatusPrevGroup 6 }
+
+ drsBladePrevStatus OBJECT-TYPE
+ SYNTAX DellStatus
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0003.0002.0007 This attribute defines the previous Blade subsystem health status
+ recorded by the chassis management card."
+ ::= { drsStatusPrevGroup 7 }
+
+ drsTempPrevStatus OBJECT-TYPE
+ SYNTAX DellStatus
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0003.0001.0008 This attribute defines the Temp Sensor health status
+ being monitored by the chassis management card."
+ ::= { drsStatusPrevGroup 8 }
+
+ drsCMCPrevStatus OBJECT-TYPE
+ SYNTAX DellStatus
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0003.0001.0009 This attribute defines the CMC health status
+ being monitored by the chassis management card."
+ ::= { drsStatusPrevGroup 9 }
+
+ drsGlobalChangeTime OBJECT-TYPE
+ SYNTAX TimeTicks
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0003.0003.0001 This attribute defines the timestamp of the most recent
+ global status change."
+ ::= { drsStatusChangeGroup 1 }
+
+ drsIOMChangeTime OBJECT-TYPE
+ SYNTAX TimeTicks
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0003.0003.0002 This attribute defines the timestamp of the most recent
+ IOM status change."
+ ::= { drsStatusChangeGroup 2 }
+
+ drsKVMChangeTime OBJECT-TYPE
+ SYNTAX TimeTicks
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0003.0003.0003 This attribute defines the timestamp of the most recent
+ iKVM status change."
+ ::= { drsStatusChangeGroup 3 }
+
+ drsRedChangeTime OBJECT-TYPE
+ SYNTAX TimeTicks
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0003.0003.0004 This attribute defines the timestamp of the most recent
+ Redundancy status change."
+ ::= { drsStatusChangeGroup 4 }
+
+ drsPowerChangeTime OBJECT-TYPE
+ SYNTAX TimeTicks
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0003.0003.0005 This attribute defines the timestamp of the most recent
+ power health status change."
+ ::= { drsStatusChangeGroup 5 }
+
+ drsFanChangeTime OBJECT-TYPE
+ SYNTAX TimeTicks
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0003.0003.0006 This attribute defines the timestamp of the most recent
+ Fan health status change."
+ ::= { drsStatusChangeGroup 6 }
+
+ drsBladeChangeTime OBJECT-TYPE
+ SYNTAX TimeTicks
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0003.0003.0007 This attribute defines the timestamp of the most recent
+ Blade health status change."
+ ::= { drsStatusChangeGroup 7 }
+
+ drsTempChangeTime OBJECT-TYPE
+ SYNTAX TimeTicks
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0003.0003.0008 This attribute defines the timestamp of the most recent
+ Temp Sensor health status change."
+ ::= { drsStatusChangeGroup 8 }
+
+ drsCMCChangeTime OBJECT-TYPE
+ SYNTAX TimeTicks
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0003.0003.0009 This attribute defines the timestamp of the most recent
+ CMC health status change."
+ ::= { drsStatusChangeGroup 9 }
+
+ -------------------------------------------------------------------------------
+ -- group: chassis power
+ -------------------------------------------------------------------------------
+
+ drsCMCPowerTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF DrsCMCPowerTableEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION "0004.0001 This object defines the CMC power table."
+ ::= { drsChassisPowerGroup 1 }
+
+ drsCMCPowerTableEntry OBJECT-TYPE
+ SYNTAX DrsCMCPowerTableEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION "0004.0001.0001 This object defines the CMC power table entry."
+ INDEX { drsChassisIndex }
+ ::= { drsCMCPowerTable 1 }
+
+ drsCMCPSUTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF DrsCMCPSUTableEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION "0004.0002 This object defines the CMC PSU table."
+ ::= { drsChassisPowerGroup 2 }
+
+ drsCMCPSUTableEntry OBJECT-TYPE
+ SYNTAX DrsCMCPSUTableEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION "0004.0002.0001 This object defines the CMC PSU table entry."
+ INDEX { drsPSUChassisIndex, drsPSUIndex }
+ ::= { drsCMCPSUTable 1 }
+
+ -------------------------------------------------------------------------------
+ -- table: CMC power information
+ -------------------------------------------------------------------------------
+
+ drsChassisIndex OBJECT-TYPE
+ SYNTAX DellCMCPowerIndexRange
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0004.0001.0001.0001 This attribute defines the index
+ (one-based) of the associated chassis."
+ ::= { drsCMCPowerTableEntry 1 }
+
+ drsPotentialPower OBJECT-TYPE
+ SYNTAX DellPowerReading
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0004.0001.0001.0002 This attribute defines the power (in Watts) required by
+ the chassis infrastructure, plus the sum of the maximum power requirements
+ for all currently powered-on servers."
+ ::= { drsCMCPowerTableEntry 2 }
+
+ drsIdlePower OBJECT-TYPE
+ SYNTAX DellPowerReading
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0004.0001.0001.0003 This attribute defines the power (in Watts) required by
+ the chassis infrastructure, plus the sum of the minimum power requirements
+ for all currently powered-on servers."
+ ::= { drsCMCPowerTableEntry 3 }
+
+ drsMaxPowerSpecification OBJECT-TYPE
+ SYNTAX DellPowerReading
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0004.0001.0001.0004 This attribute defines the power limit (in Watts)
+ at which server throttling will take place."
+ ::= { drsCMCPowerTableEntry 4 }
+
+
+ drsPowerSurplus OBJECT-TYPE
+ SYNTAX DellPowerReading
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0004.0001.0001.0005 This attribute defines the power surplus (in Watts)
+ remaining above the drsPotentialPower reading."
+ ::= { drsCMCPowerTableEntry 5 }
+
+ drsKWhCumulative OBJECT-TYPE
+ SYNTAX DellPowerReading
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0004.0001.0001.0006 This attribute defines the cumulative chassis power
+ usage (in KWh) since last reset."
+ ::= { drsCMCPowerTableEntry 6 }
+
+ drsKWhCumulativeTime OBJECT-TYPE
+ SYNTAX DellTimestamp
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0004.0001.0001.0007 This attribute defines the timestamp of the most recent
+ chassis power accumulator reset."
+ ::= { drsCMCPowerTableEntry 7 }
+
+ drsWattsPeakUsage OBJECT-TYPE
+ SYNTAX DellPowerReading
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0004.0001.0001.0008 This attribute defines the chassis peak power
+ usage (in Watts) since last reset."
+ ::= { drsCMCPowerTableEntry 8 }
+
+ drsWattsPeakTime OBJECT-TYPE
+ SYNTAX DellTimestamp
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0004.0001.0001.0009 This attribute defines the timestamp of the most recent
+ chassis peak power usage."
+ ::= { drsCMCPowerTableEntry 9 }
+
+ drsWattsMinUsage OBJECT-TYPE
+ SYNTAX DellPowerReading
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0004.0001.0001.0010 This attribute defines the chassis mimimum power
+ usage (in Watts) since last reset."
+ ::= { drsCMCPowerTableEntry 10 }
+
+ drsWattsMinTime OBJECT-TYPE
+ SYNTAX DellTimestamp
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0004.0001.0001.0011 This attribute defines the timestamp of the most recent
+ chassis minimum power usage."
+ ::= { drsCMCPowerTableEntry 11 }
+
+ drsWattsResetTime OBJECT-TYPE
+ SYNTAX DellTimestamp
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0004.0001.0001.0012 This attribute defines the timestamp of the most recent
+ reset of the chassis min/peak Watts readings."
+ ::= { drsCMCPowerTableEntry 12 }
+
+ drsWattsReading OBJECT-TYPE
+ SYNTAX DellPowerReading
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0004.0001.0001.0013 This attribute defines the instantaneous chassis power
+ usage (in Watts)."
+ ::= { drsCMCPowerTableEntry 13 }
+
+ drsAmpsReading OBJECT-TYPE
+ SYNTAX DellPowerReading
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0004.0001.0001.0014 This attribute defines the instantaneous chassis current
+ usage (in Watts)."
+ ::= { drsCMCPowerTableEntry 14 }
+
+ -------------------------------------------------------------------------------
+ -- table: CMC PSU info
+ -------------------------------------------------------------------------------
+
+ drsPSUChassisIndex OBJECT-TYPE
+ SYNTAX DellCMCPowerIndexRange
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0004.0002.0001.0001 This attribute defines the index
+ (one-based) of the associated chassis."
+ ::= { drsCMCPSUTableEntry 1 }
+
+ drsPSUIndex OBJECT-TYPE
+ SYNTAX DellCMCPSUIndexRange
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0004.0002.0001.0002 This attribute defines the index
+ (one-based) of the associated CMC PSU."
+ ::= { drsCMCPSUTableEntry 2 }
+
+ drsPSULocation OBJECT-TYPE
+ SYNTAX DellString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0004.0002.0001.0003 This attribute defines the location
+ of the CMC PSU."
+ ::= { drsCMCPSUTableEntry 3 }
+
+ drsPSUMonitoringCapable OBJECT-TYPE
+ SYNTAX DellCMCPSUCapable
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0004.0002.0001.0004 This attribute defines the PSU Monitoring
+ capabilities, or the absence of a PSU in this location."
+ ::= { drsCMCPSUTableEntry 4 }
+
+ drsPSUVoltsReading OBJECT-TYPE
+ SYNTAX DellPowerReading
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0004.0002.0001.0005 This attribute defines the instantaneous
+ PSU Voltage reading."
+ ::= { drsCMCPSUTableEntry 5 }
+
+ drsPSUAmpsReading OBJECT-TYPE
+ SYNTAX DellPowerReading
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0004.0002.0001.0006 This attribute defines the instantaneous
+ PSU Current reading."
+ ::= { drsCMCPSUTableEntry 6 }
+
+ drsPSUWattsReading OBJECT-TYPE
+ SYNTAX DellPowerReading
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0004.0002.0001.0007 This attribute defines the instantaneous
+ PSU Wattage reading."
+ ::= { drsCMCPSUTableEntry 7 }
+
+ -------------------------------------------------------------------------------
+ -- group: chassis servers
+ -------------------------------------------------------------------------------
+
+ drsCMCServerTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF DrsCMCServerTableEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION "0005.0001 This object defines the CMC server table."
+ ::= { drsChassisServerGroup 1 }
+
+ drsCMCServerTableEntry OBJECT-TYPE
+ SYNTAX DrsCMCServerTableEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION "0005.0001.0001 This object defines the CMC server table entry."
+ INDEX { drsServerIndex }
+ ::= { drsCMCServerTable 1 }
+
+ -------------------------------------------------------------------------------
+ -- table: CMC Server info
+ -------------------------------------------------------------------------------
+
+ drsServerIndex OBJECT-TYPE
+ SYNTAX DellCMCServerIndexRange
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0005.0001.0001.0001 This attribute defines the index
+ (one-based) of the associated CMC server."
+ ::= { drsCMCServerTableEntry 1 }
+
+ drsServerMonitoringCapable OBJECT-TYPE
+ SYNTAX DellCMCServerCapable
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0005.0001.0001.0002 This attribute defines the server monitoring
+ capabilities, or the absence of a server in this location."
+ ::= { drsCMCServerTableEntry 2 }
+
+ drsServerServiceTag OBJECT-TYPE
+ SYNTAX DellString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0005.0001.0001.0003 This attribute defines the Service Tag
+ of the CMC server."
+ ::= { drsCMCServerTableEntry 3 }
+
+ drsServerSlotName OBJECT-TYPE
+ SYNTAX DellString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0005.0001.0001.0004 This attribute defines the Slot Name
+ of the CMC server."
+ ::= { drsCMCServerTableEntry 4 }
+
+ drsServerSlotNumber OBJECT-TYPE
+ SYNTAX DellString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0005.0001.0001.0005 This attribute defines the Chassis
+ Slot Number of the CMC server."
+ ::= { drsCMCServerTableEntry 5 }
+
+ drsServerNodeID OBJECT-TYPE
+ SYNTAX DellString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0005.0001.0001.0006 This attribute defines the Node ID
+ of the CMC server. The Node ID provides a unique identifier
+ for the server."
+ ::= { drsCMCServerTableEntry 6 }
+
+ drsServerModel OBJECT-TYPE
+ SYNTAX DellString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0005.0001.0001.0007 This attribute defines the Model
+ of the CMC server."
+ ::= { drsCMCServerTableEntry 7 }
+
+ drsServerAssetTag OBJECT-TYPE
+ SYNTAX DellString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0005.0001.0001.0008 This attribute defines the Asset Tag
+ of the CMC server."
+ ::= { drsCMCServerTableEntry 8 }
+
+ drsServerNumStorageControllers OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0005.0001.0001.0009 This attribute defines the number of
+ storage controllers on the storage sled. The value
+ will be zero if this is not a storage sled."
+ ::= { drsCMCServerTableEntry 9 }
+
+ drsServerStorageMode OBJECT-TYPE
+ SYNTAX DellCMCServerStorageMode
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0005.0001.0001.0010 This attribute defines the Storage
+ Mode of the storage sled."
+ ::= { drsCMCServerTableEntry 10 }
+
+ drsServerIntrusionState OBJECT-TYPE
+ SYNTAX DellCMCServerIntrusionState
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0005.0001.0001.0011 This attribute defines the Intrusion
+ State of the CMC server if supported by the server."
+ ::= { drsCMCServerTableEntry 11 }
+
+ drsServerAssignedServerSlots OBJECT-TYPE
+ SYNTAX DellString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0005.0001.0001.0012 This attribute defines the the server
+ slots to which a storage sled is assigned. If this is
+ a storage sled that is assigned to one more or more
+ server slots, the value will be a comma-separated list
+ of one or more server slot names. If the storage sled
+ is not assigned to a server slot, the value will be an
+ empty string. If this is not a storage sled, the value
+ will be N/A."
+ ::= { drsCMCServerTableEntry 12 }
+
+-------------------------------------------------------------------------------
+-- Storage Details Group
+--
+-- OID Format: 1.3.6.1.4.1.674.10892.5.5
+-------------------------------------------------------------------------------
+
+
+-------------------------------------------------------------------------------
+-- Battery Table
+--
+-- OID Format:.1.3.6.1.4.1.674.10892.2.6.1.20.130.15.1.<a>.<i1>
+-------------------------------------------------------------------------------
+
+BatteryTableEntry ::=SEQUENCE {
+ batteryNumber INTEGER,
+ batteryState INTEGER,
+ batteryComponentStatus ObjectStatusEnum,
+ batteryPredictedCapacity INTEGER,
+ batteryFQDD DisplayString,
+ batteryDisplayName DisplayString
+}
+
+batteryTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BatteryTableEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A table of managed batteries. The number of
+ entries is related to number of Batteries
+ discovered in the system. The maximum number of entries
+ is implementation dependent.
+ Note: The properties in this table may not be applicable to all
+ entries.
+ "
+ ::= { physicalDevices 15 }
+
+batteryTableEntry OBJECT-TYPE
+ SYNTAX BatteryTableEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "An entry in the battery table. A row in this table cannot be
+ created or deleted by SNMP operations on columns of the table.
+ "
+ INDEX { batteryNumber }
+ ::= { batteryTable 1 }
+
+batteryNumber OBJECT-TYPE
+ SYNTAX INTEGER (1..255)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Instance number of this battery entry.
+ "
+ ::= { batteryTableEntry 1 }
+
+batteryState OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ unknown(1),
+ ready(2),
+ failed(3),
+ degraded(4),
+ missing(5),
+ charging(6),
+ belowThreshold(7)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Current state of battery.
+ Possible values:
+ 1: The current state could not be determined.
+ 2: The battery is operating normally.
+ 3: The battery has failed and needs to be replaced.
+ 4: The battery temperature is high or charge level is depleting.
+ 5: The battery is missing or not detected.
+ 6: The battery is undergoing the re-charge phase.
+ 7: The battery voltage or charge level is below the threshold.
+ "
+ ::= { batteryTableEntry 4 }
+
+batteryComponentStatus OBJECT-TYPE
+ SYNTAX ObjectStatusEnum
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The status of the battery itself without the
+ propagation of any contained component status.
+ Possible values:
+ 1: Other
+ 2: Unknown
+ 3: OK
+ 4: Non-critical
+ 5: Critical
+ 6: Non-recoverable"
+ ::= { batteryTableEntry 6 }
+
+batteryPredictedCapacity OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ unknown(1),
+ failed(2),
+ ready(3)
+ }
+ ACCESS read-only
+ STATUS obsolete
+ DESCRIPTION
+ "This entry is obsolete. Use the batteryComponentStatus or
+ batteryState instead.
+ "
+ ::= { batteryTableEntry 10 }
+
+batteryFQDD OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The battery's Fully Qualified Device Descriptor (FQDD) as
+ represented in Storage Management.
+ "
+ ::= { batteryTableEntry 20 }
+
+batteryDisplayName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The battery's friendly FQDD as represented in Storage Management."
+ ::= { batteryTableEntry 21 }
+
+
+
+
+-------------------------------------------------------------------------------
+-- Controller Table
+--
+-- OID Format:.1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.<a>.<i1>
+-------------------------------------------------------------------------------
+
+ControllerTableEntry ::=SEQUENCE {
+ controllerNumber INTEGER,
+ controllerName DisplayString,
+ controllerRebuildRate INTEGER,
+ controllerFWVersion DisplayString,
+ controllerCacheSizeInMB INTEGER,
+ controllerRollUpStatus ObjectStatusEnum,
+ controllerComponentStatus ObjectStatusEnum,
+ controllerDriverVersion DisplayString,
+ controllerPCISlot DisplayString,
+ controllerReconstructRate INTEGER,
+ controllerPatrolReadRate INTEGER,
+ controllerBGIRate INTEGER,
+ controllerCheckConsistencyRate INTEGER,
+ controllerPatrolReadMode INTEGER,
+ controllerPatrolReadState INTEGER,
+ controllerPersistentHotSpare BooleanType,
+ controllerSpinDownUnconfiguredDrives BooleanType,
+ controllerSpinDownHotSpareDrives BooleanType,
+ controllerSpinDownTimeInterval INTEGER,
+ controllerPreservedCache BooleanType,
+ controllerCheckConsistencyMode INTEGER,
+ controllerCopyBackMode INTEGER,
+ controllerSecurityStatus INTEGER,
+ controllerEncryptionKeyPresent BooleanType,
+ controllerEncryptionCapability INTEGER,
+ controllerLoadBalanceSetting INTEGER,
+ controllerMaxCapSpeed INTEGER,
+ controllerSASAddress DisplayString,
+ controllerFQDD FQDDString,
+ controllerDisplayName DisplayString,
+ controllerT10PICapability INTEGER,
+ controllerRAID10UnevenSpansSupported BooleanType,
+ controllerEnhancedAutoImportForeignConfigMode INTEGER,
+ controllerBootModeSupported BooleanType,
+ controllerBootMode INTEGER,
+ controllerHighAvailabilityMode INTEGER,
+ controllerPeerController FQDDString,
+ controllerEncryptionKeyIdentifier DisplayString
+}
+
+controllerTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ControllerTableEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A table of managed RAID controllers. The number of entries
+ is related to number of RAID controllers discovered in the
+ system. The maximum number of entries is implementation dependent.
+ Note: The properties in this table may not be applicable to all
+ entries.
+ "
+ ::= { physicalDevices 1 }
+
+controllerTableEntry OBJECT-TYPE
+ SYNTAX ControllerTableEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "An entry in the table of RAID controllers. A row in this table
+ cannot be created or deleted by SNMP operations on columns of
+ the table."
+ INDEX { controllerNumber }
+ ::= { controllerTable 1 }
+
+controllerNumber OBJECT-TYPE
+ SYNTAX INTEGER (1..255)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Instance number of this controller entry."
+ ::= { controllerTableEntry 1 }
+
+
+controllerName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The controller's name as represented in Storage Management.
+ "
+ ::= { controllerTableEntry 2 }
+
+controllerRebuildRate OBJECT-TYPE
+ SYNTAX INTEGER (0..100)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The rebuild rate is the percentage of the controller's
+ resources dedicated to rebuilding a failed disk when a rebuild
+ is necessary.
+ "
+ ::= { controllerTableEntry 7 }
+
+controllerFWVersion OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The controller's current firmware version.
+ "
+ ::= { controllerTableEntry 8 }
+
+controllerCacheSizeInMB OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The controller's current amount of cache memory in megabytes.
+ "
+ ::= { controllerTableEntry 9 }
+
+controllerRollUpStatus OBJECT-TYPE
+ SYNTAX ObjectStatusEnum
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Severity of the controller state.
+ This is the combined status of the controller and its components.
+ Possible values:
+ 1: Other.
+ 2: Unknown.
+ 3: OK
+ 4: Non-critical
+ 5: Critical.
+ 6: Non-recoverable.
+ "
+ ::= { controllerTableEntry 37 }
+
+controllerComponentStatus OBJECT-TYPE
+ SYNTAX ObjectStatusEnum
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The status of the controller itself without the
+ propagation of any contained component status.
+ Possible values:
+ 1: Other
+ 2: Unknown
+ 3: OK
+ 4: Non-critical
+ 5: Critical
+ 6: Non-recoverable"
+ ::= { controllerTableEntry 38 }
+
+controllerDriverVersion OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Currently installed driver version for this controller on the host.
+ "
+ ::= { controllerTableEntry 41 }
+
+controllerPCISlot OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The PCI slot on the server where the controller is seated. This
+ data is not reported for embedded or integrated controllers,
+ "
+ ::= { controllerTableEntry 42 }
+
+controllerReconstructRate OBJECT-TYPE
+ SYNTAX INTEGER (0..100)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The reconstruct rate is the percentage of the controller's resources
+ dedicated to reconstructing a disk group after adding a physical disk
+ or changing the RAID level of a virtual disk residing on the disk
+ group.
+ "
+ ::= { controllerTableEntry 48 }
+
+controllerPatrolReadRate OBJECT-TYPE
+ SYNTAX INTEGER (0..100)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The patrol read rate is the percentage of the controller's
+ resources dedicated to perform a patrol read on disks participating
+ in a virtual disk or hot spares.
+ "
+ ::= { controllerTableEntry 49 }
+
+controllerBGIRate OBJECT-TYPE
+ SYNTAX INTEGER (0..100)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The background initialization (BGI) rate is the percentage of the
+ controller's resources dedicated to performing the background
+ initialization of a redundant virtual disk after it is created.
+ "
+ ::= { controllerTableEntry 50 }
+
+controllerCheckConsistencyRate OBJECT-TYPE
+ SYNTAX INTEGER (0..100)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The check consistency rate is the percentage of the
+ controller's resources dedicated to performing a check consistency
+ on a redundant virtual disk.
+ "
+ ::= { controllerTableEntry 51 }
+
+controllerPatrolReadMode OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ other(1),
+ notSupported(2),
+ disabled(3),
+ auto(4),
+ manual(5)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Identifies the patrol read mode setting for the controller.
+ Possible values:
+ 1: Not one of the following or could not be determined.
+ 2: Not Supported on this controller.
+ 3: Disabled.
+ 4: Automatic.
+ 5: Manual.
+ "
+ ::= { controllerTableEntry 52 }
+
+controllerPatrolReadState OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ other(1),
+ stopped(2),
+ active(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This property displays the current state of the patrol read process.
+ Possible values:
+ 1: Not one of the following or could not be determined.
+ 2: Patrol read is not running.
+ 3: Patrol read is running.
+ "
+ ::= { controllerTableEntry 53 }
+
+controllerPersistentHotSpare OBJECT-TYPE
+ SYNTAX BooleanType
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates whether hot spare drives would be restored on insertion
+ into the same slot.
+ "
+ ::= { controllerTableEntry 59 }
+
+controllerSpinDownUnconfiguredDrives OBJECT-TYPE
+ SYNTAX BooleanType
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates whether un-configured drives would be put in power
+ save mode by the controller.
+ "
+ ::= { controllerTableEntry 60 }
+
+controllerSpinDownHotSpareDrives OBJECT-TYPE
+ SYNTAX BooleanType
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates whether hot spare drives would be put in power
+ save mode by the controller.
+ "
+ ::= { controllerTableEntry 61 }
+
+controllerSpinDownTimeInterval OBJECT-TYPE
+ SYNTAX INTEGER (30..1440)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The duration in minutes after which, the unconfigured or hot
+ spare drives will be spun down to power save mode.
+ "
+ ::= { controllerTableEntry 62 }
+
+controllerPreservedCache OBJECT-TYPE
+ SYNTAX BooleanType
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates whether preserved cache or pinned cache is
+ present on the controller.
+ "
+ ::= { controllerTableEntry 69 }
+
+controllerCheckConsistencyMode OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ other(1),
+ unsupported(2),
+ normal(3),
+ stopOnError(4)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The current check consistency mode setting
+ for the controller.
+ Possible values:
+ 1: Not one of the following.
+ 2: Not supported on this controller.
+ 3: Normal check consistency operation.
+ 4: Check consistency operation will stop on encountering
+ an error.
+ "
+ ::= { controllerTableEntry 70 }
+
+controllerCopyBackMode OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ other(1),
+ unsupported(2),
+ on(3),
+ onWithSmart(4),
+ off(5)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The current copy back mode setting
+ for the controller.
+ Possible values:
+ 1: Not one of the following.
+ 2: Not supported on this controller.
+ 3: Disks assigned as spares could revert back to spare status.
+ 4: Data from physical disk participating in a
+ virtual disk could be automatically copied to the assigned
+ hot spare in case former has a predictive failure event.
+ 5: Copyback mode is disabled.
+ "
+ ::= { controllerTableEntry 71 }
+
+controllerSecurityStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ unknown(1),
+ none(2),
+ lkm(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The controller's current security/encryption status..
+ Possible values:
+ 1: The current status could not be determined.
+ 2: Controller is not operating in an encryption mode.
+ 3: Controller is operating in the Local Key Management
+ (LKM) encryption mode.
+ "
+ ::= { controllerTableEntry 72 }
+
+controllerEncryptionKeyPresent OBJECT-TYPE
+ SYNTAX BooleanType
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates whether encryption key is assigned for the controller.
+ "
+ ::= { controllerTableEntry 73 }
+
+controllerEncryptionCapability OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ other(1),
+ none(2),
+ lkm(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The type of encryption supported by the controller.
+ Possible values:
+ 1: Not one of the following.
+ 2: No encryption supported,
+ 3: Local Key Management,
+ "
+ ::= { controllerTableEntry 74 }
+
+controllerLoadBalanceSetting OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ other(1),
+ unsupported(2),
+ auto(3),
+ none(4)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The ability of the controller to automatically use both
+ controller ports (or connectors) connected to the same enclosure in
+ order to route I/O requests.
+ Possible values:
+ 1: Not one of the following.
+ 2: Not supported.
+ 3: Automatic load balancing is active.
+ 4: Load balancing is inactive.
+ "
+ ::= { controllerTableEntry 75 }
+
+controllerMaxCapSpeed OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ unknown(1),
+ oneDotFiveGbps(2),
+ threeGbps(3),
+ sixGbps(4),
+ twelveGbps(5)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The maximum speed of the controller.in
+ Gigbits per second (Gbps).
+ Possible values:
+ 1: The speed could not be determined.
+ 2. 1.5 Gbps
+ 3: 3.0 Gbps
+ 4: 6.0 Gbps
+ 5: 12.0 Gbps
+ "
+ ::= { controllerTableEntry 76 }
+
+controllerSASAddress OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The SAS address of the controller.
+ "
+ ::= { controllerTableEntry 77 }
+
+controllerFQDD OBJECT-TYPE
+ SYNTAX FQDDString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The controller's Fully Qualified Device Descriptor (FQDD) as
+ represented in Storage Management.
+ "
+ ::= { controllerTableEntry 78 }
+
+controllerDisplayName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The controller's friendly FQDD as represented in Storage
+ Management."
+ ::= { controllerTableEntry 79 }
+
+controllerT10PICapability OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ other(1),
+ capable(2),
+ notCapable(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates whether the controller supports the T10 PI (Protection
+ Information). These protection fields are known as DIF
+ (Data Integrity Fields).
+ Possible values:
+ 1: Not one of the following.
+ 2: Capable of supporting T10 PI.
+ 3: Not capable of supporting T10 PI.
+ "
+ ::= { controllerTableEntry 80 }
+
+controllerRAID10UnevenSpansSupported OBJECT-TYPE
+ SYNTAX BooleanType
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates whether uneven spans for RAID 10 virtual disk
+ is supported on the controller.
+ "
+ ::= { controllerTableEntry 81 }
+
+controllerEnhancedAutoImportForeignConfigMode OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ other(1),
+ notSupported(2),
+ disabled(3),
+ enabled(4)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the status of enhanced auto-import of foreign
+ configuration property of the controller.
+ 1: Not one of the following.
+ 2: Not Supported.
+ 3: Disabled.
+ 4: Enabled.
+ "
+ ::= { controllerTableEntry 82 }
+
+controllerBootModeSupported OBJECT-TYPE
+ SYNTAX BooleanType
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates whether headless boot mode settings are supported
+ on the controller.
+ "
+ ::= { controllerTableEntry 83 }
+
+controllerBootMode OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ notApplicable(1),
+ user(2),
+ contOnError(3),
+ headlessContOnError(4),
+ headlessSafe(5)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the boot mode of the controller.
+ Possible values:
+ 1: Not applicable for this controller.
+ 2: User mode: User interaction required for all boot messages (not
+ applicable for uEFI environments).
+ 3: Continue Boot On Error. User interaction only required for
+ critical messages.
+ 4: Headless Mode Continue On Error. User interaction is not required.
+ Controller boot may halt on Error.
+ 5: Headless Safe Mode. Controller shall boot to safe mode on critical
+ errors.
+ "
+ ::= { controllerTableEntry 84 }
+
+controllerHighAvailabilityMode OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ none (1),
+ faultTolerantActivePassive (2),
+ faultTolerantActiveActive (3),
+ degraded (4)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the fault-tolerant mode of the controller.
+ Possible values:
+ 1: None
+ 2: Fault Tolerant(Active/Passive)
+ 3: Fault Tolerant(Active/Active)
+ 4: Degraded
+ "
+ ::= { controllerTableEntry 85 }
+
+controllerPeerController OBJECT-TYPE
+ SYNTAX FQDDString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The peer controller's Fully Qualified Device Descriptor (FQDD) as
+ represented in Storage Management.
+ "
+ ::= { controllerTableEntry 86 }
+
+controllerEncryptionKeyIdentifier OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Displays the encryption security key identifier of the controller, if the
+ controller is encryption enabled and a security key is configured for the
+ controller."
+ ::= { controllerTableEntry 87 }
+
+
+
+
+-------------------------------------------------------------------------------
+-- Physical Disk Table
+--
+-- OID Format:.1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.<a>.<i1>
+-------------------------------------------------------------------------------
+
+PhysicalDiskTableEntry ::=SEQUENCE {
+ physicalDiskNumber INTEGER,
+ physicalDiskName DisplayString,
+ physicalDiskManufacturer DisplayString,
+ physicalDiskState INTEGER,
+ physicalDiskProductID DisplayString,
+ physicalDiskSerialNo DisplayString,
+ physicalDiskRevision DisplayString,
+ physicalDiskCapacityInMB INTEGER,
+ physicalDiskUsedSpaceInMB INTEGER,
+ physicalDiskFreeSpaceInMB INTEGER,
+ physicalDiskBusType INTEGER,
+ physicalDiskSpareState INTEGER,
+ physicalDiskComponentStatus ObjectStatusEnum,
+ physicalDiskPartNumber DisplayString,
+ physicalDiskSASAddress DisplayString,
+ physicalDiskNegotiatedSpeed INTEGER,
+ physicalDiskCapableSpeed INTEGER,
+ physicalDiskSmartAlertIndication BooleanType,
+ physicalDiskManufactureDay DisplayString,
+ physicalDiskManufactureWeek DisplayString,
+ physicalDiskManufactureYear DisplayString,
+ physicalDiskMediaType INTEGER,
+ physicalDiskPowerState INTEGER,
+ physicalDiskRemainingRatedWriteEndurance INTEGER,
+ physicalDiskOperationalState INTEGER,
+ physicalDiskProgress INTEGER,
+ physicalDiskSecurityStatus INTEGER,
+ physicalDiskFormFactor INTEGER,
+ physicalDiskFQDD FQDDString,
+ physicalDiskDisplayName DisplayString,
+ physicalDiskT10PICapability INTEGER,
+ physicalDiskBlockSizeInBytes INTEGER,
+ physicalDiskProtocolVersion DisplayString,
+ physicalDiskPCIeNegotiatedLinkWidth INTEGER,
+ physicalDiskPCIeCapableLinkWidth INTEGER,
+ physicalDiskCurrentActiveController FQDDString,
+ physicalDiskFailoverController FQDDString,
+ physicalDiskForeignKeyIdentifier DisplayString
+ }
+
+physicalDiskTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PhysicalDiskTableEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A table of managed physical disks. The number of entries is
+ related to number of physical Disks discovered in the system.
+ The maximum number of entries is implementation dependent.
+ Note: The properties in this table may not be applicable to
+ all entries.
+ "
+ ::= { physicalDevices 4 }
+
+physicalDiskTableEntry OBJECT-TYPE
+ SYNTAX PhysicalDiskTableEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "An entry in the physical Disk table. A row in this table cannot be
+ created or deleted by SNMP operations on columns of the table.
+ "
+ INDEX { physicalDiskNumber }
+ ::= { physicalDiskTable 1 }
+
+physicalDiskNumber OBJECT-TYPE
+ SYNTAX INTEGER (1..1000000000)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Instance number of this physical disk entry.
+ "
+ ::= { physicalDiskTableEntry 1 }
+
+physicalDiskName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The physical disk's name as represented in Storage Management.
+ "
+ ::= { physicalDiskTableEntry 2 }
+
+physicalDiskManufacturer OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the physical disk's manufacturer.
+ "
+ ::= { physicalDiskTableEntry 3 }
+
+physicalDiskState OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ unknown(1),
+ ready(2),
+ online(3),
+ foreign(4),
+ offline(5),
+ blocked(6),
+ failed(7),
+ nonraid(8),
+ removed(9),
+ readonly(10)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The current state of this physical disk.
+ Possible states:
+ 1: The current state could not be determined.
+ 2: The physical disk is available for use, but no RAID configuration
+ has been assigned.
+ 3: A RAID configuration has been assigned to the physical disk.
+ 4: The physical disk has been moved from another
+ controller and contains all or some portion of a virtual disk.
+ 5: The physical disk is not available to the RAID
+ controller.
+ 6: The physical disk is currently blocked by
+ controller.
+ 7: The physical disk is not operational.
+ 8: The physical disk is not a RAID capable disk
+ 9: The physical disk has been removed.
+ 10:The physical disk media has been placed in read only mode.
+ "
+ ::= { physicalDiskTableEntry 4 }
+
+physicalDiskProductID OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The model number of the physical disk.
+ "
+ ::= { physicalDiskTableEntry 6 }
+
+physicalDiskSerialNo OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The physical disk's unique identification number
+ from the manufacturer.
+ "
+ ::= { physicalDiskTableEntry 7 }
+
+physicalDiskRevision OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The firmware version of the physical disk.
+ "
+ ::= { physicalDiskTableEntry 8 }
+
+physicalDiskCapacityInMB OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The size of the physical disk in megabytes.
+ "
+ ::= { physicalDiskTableEntry 11 }
+
+physicalDiskUsedSpaceInMB OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The amount of used space in megabytes on the physical
+ disk. This is not applicable for NVMe devices.
+ "
+ ::= { physicalDiskTableEntry 17 }
+
+physicalDiskFreeSpaceInMB OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The amount of free space in megabytes on the physical
+ disk. This is not applicable for NVMe devices.
+ "
+ ::= { physicalDiskTableEntry 19 }
+
+physicalDiskBusType OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ unknown(1),
+ scsi(2),
+ sas(3),
+ sata(4),
+ fibre(5),
+ pcie(6)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The bus type of the physical disk.
+ Possible values:
+ 1: The bus type could not be determined.
+ 2: Small Computer System Interface (SCSI).
+ 3: Serial Attached SCSI (SAS).
+ 4: Serial Advanced Technology Attachment (SATA).
+ 5: Fibre channel.
+ 6: PCIe.
+ "
+ ::= { physicalDiskTableEntry 21 }
+
+physicalDiskSpareState OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ notASpare(1),
+ dedicatedHotSpare(2),
+ globalHotSpare(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The status of the disk as a spare.
+ Possible values:
+ 1: Physical disk is not a spare.
+ 2: Physical disk is a dedicated hot spare.
+ 3: Physical disk is a global hot spare.
+ "
+ ::= { physicalDiskTableEntry 22 }
+
+physicalDiskComponentStatus OBJECT-TYPE
+ SYNTAX ObjectStatusEnum
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The status of the physical disk itself without the
+ propagation of any contained component status.
+ Possible values:
+ 1: Other
+ 2: Unknown
+ 3: OK
+ 4: Non-critical
+ 5: Critical
+ 6: Non-recoverable
+ "
+ ::= { physicalDiskTableEntry 24 }
+
+physicalDiskPartNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The part number of the disk.
+ "
+ ::= { physicalDiskTableEntry 27 }
+
+physicalDiskSASAddress OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The SAS address of the physical disk.
+ "
+ ::= { physicalDiskTableEntry 28 }
+
+physicalDiskNegotiatedSpeed OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ unknown(1),
+ oneDotFiveGbps(2),
+ threeGbps(3),
+ sixGbps(4),
+ twelveGbps(5),
+ fiveGTps(6),
+ eightGTps(7)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The data transfer speed that the disk negotiated while spinning up
+ in Gigbits per second (Gbps).
+ Possible values:
+ 1: The speed could not be determined.
+ 2. 1.5 Gbps
+ 3: 3.0 Gbps
+ 4: 6.0 Gbps
+ 5: 12.0 Gbps
+ 6: 5 GT/s (applicable for NVMe devices).
+ 7: 8 GT/s (applicable for NVMe devices).
+ "
+ ::= { physicalDiskTableEntry 29 }
+
+physicalDiskCapableSpeed OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ unknown(1),
+ oneDotFiveGbps(2),
+ threeGbps(3),
+ sixGbps(4),
+ twelveGbps(5),
+ fiveGTps(6),
+ eightGTps(7)
+
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The maximum data transfer speed supported by the disk
+ in Gigbits per second (Gbps).
+ Possible values:
+ 1: The speed could not be determined.
+ 2. 1.5 Gbps
+ 3: 3.0 Gbps
+ 4: 6.0 Gbps
+ 5: 12.0 Gbps
+ 6: 5 GT/s (applicable for NVMe devices).
+ 7: 8 GT/s (applicable for NVMe devices).
+ "
+ ::= { physicalDiskTableEntry 30 }
+
+physicalDiskSmartAlertIndication OBJECT-TYPE
+ SYNTAX BooleanType
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates whether the physical disk has received a predictive
+ failure alert.
+ "
+ ::= { physicalDiskTableEntry 31 }
+
+physicalDiskManufactureDay OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The day of the week (1=Sunday thru 7=Saturday)
+ on which the physical disk was manufactured.
+ "
+ ::= { physicalDiskTableEntry 32 }
+
+physicalDiskManufactureWeek OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The week (1 thru 53) in which the physical disk
+ was manufactured.
+ "
+ ::= { physicalDiskTableEntry 33 }
+
+physicalDiskManufactureYear OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The four digit year in which the physical disk was manufactured.
+ "
+ ::= { physicalDiskTableEntry 34 }
+
+physicalDiskMediaType OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ unknown(1),
+ hdd(2),
+ ssd(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The media type of the physical disk.
+ Possible Values:
+ 1: The media type could not be determined.
+ 2: Hard Disk Drive (HDD).
+ 3: Solid State Device (SSD).
+ "
+ ::= { physicalDiskTableEntry 35 }
+
+physicalDiskPowerState OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ other(1),
+ spunUp(2),
+ spunDown(3),
+ transition(4),
+ on(5)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The power state of the physical disk.
+ Possible Values:
+ 1: Not one of the following.
+ 2: The physical disk is in the spun up state.
+ 3: The physical disk is in the spun down state.
+ 4: The physical disk is changing from spun down state
+ to spun up state or vice versa.
+ 5: The Solid State Device (SSD) is powered on.
+ "
+ ::= { physicalDiskTableEntry 42 }
+
+physicalDiskRemainingRatedWriteEndurance OBJECT-TYPE
+ SYNTAX INTEGER (0..255)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This property is applicable to SSD media type only. This indicates
+ the wear-out percentage of the SSD. Typically it is a value between
+ 0 to 100. However, if the value is not available or not applicable
+ (in the case of HDD media type) the value will be 255.
+ "
+ ::= { physicalDiskTableEntry 49 }
+
+physicalDiskOperationalState OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ notApplicable(1),
+ rebuild(2),
+ clear(3),
+ copyback(4)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The state of the physical disk when there are progressive
+ operations ongoing.
+ Possible values:
+ 1: There is no active operation running.
+ 2: Data from a redundant virtual disk is
+ currently being rebuilt onto the physical disk.
+ 3: Data on the disk is being erased.
+ 4: Data is being copied from a hot spare disk to
+ the physical disk or vice versa.
+ "
+ ::= { physicalDiskTableEntry 50 }
+
+physicalDiskProgress OBJECT-TYPE
+ SYNTAX INTEGER (0..100)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The progress percentage of the operation that is being
+ performed on the physical disk. This is applicable
+ only if there is a progressive operations ongoing
+ "
+ ::= { physicalDiskTableEntry 51 }
+
+physicalDiskSecurityStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ supported(1),
+ notSupported(2),
+ secured(3),
+ locked(4),
+ foreign(5)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The security/encryption status of the physical disk.
+ Possible Values:
+ 1: The physical disk supports encryption.
+ 2: The physical disk does not support encryption
+ 3: The physical disk is encrypted.
+ 4: The physical disk is locked by a key.
+ 5: The physical disk is locked by a foreign key.
+ "
+ ::= { physicalDiskTableEntry 52 }
+
+physicalDiskFormFactor OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ unknown(1),
+ oneDotEight(2),
+ twoDotFive(3),
+ threeDotFive(4)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The form factor of the physical disk.
+ Possible values:
+ 1: The form factor could not be determined.
+ 2: 1.8 inch.
+ 3: 2.5 inch.
+ 4: 3.5 inch.
+ "
+ ::= { physicalDiskTableEntry 53 }
+
+physicalDiskFQDD OBJECT-TYPE
+ SYNTAX FQDDString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The physical disk's Fully Qualified Device Descriptor (FQDD)
+ as represented in Storage Management.
+ "
+ ::= { physicalDiskTableEntry 54 }
+
+physicalDiskDisplayName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The physical disk's friendly FQDD as represented in Storage
+ Management.
+ "
+ ::= { physicalDiskTableEntry 55 }
+
+physicalDiskT10PICapability OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ other(1),
+ capable(2),
+ notCapable(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates whether the physical disk supports the T10 PI (Protection
+ Information). These protection fields are known as DIF
+ (Data Integrity Fields).
+ Possible values:
+ 1: Not one of the following.
+ 2: Capable of supporting T10 PI.
+ 3: Not capable of supporting T10 PI.
+ "
+ ::= { physicalDiskTableEntry 57 }
+
+physicalDiskBlockSizeInBytes OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The block size (in bytes) of the physical disk. This is not
+ applicable for NVMe devices.
+ Possible values:
+ 1: 512.
+ 2: 4096
+ "
+ ::= { physicalDiskTableEntry 58 }
+
+physicalDiskProtocolVersion OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Applicable for NVMe devices only. The NVMe protocol version supported
+ by the device.
+ "
+ ::= { physicalDiskTableEntry 59 }
+
+physicalDiskPCIeNegotiatedLinkWidth OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ other(1),
+ notApplicable(2),
+ byOne(3),
+ byTwp(4),
+ byFour(5),
+ byEight(6),
+ bySixteen(7),
+ byThirtyTwp(8)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Applicable for NVMe devices only. The PCIe link width negotiated with the host
+ during device initialization.
+ "
+ ::= { physicalDiskTableEntry 60 }
+
+physicalDiskPCIeCapableLinkWidth OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ other(1),
+ notApplicable(2),
+ byOne(3),
+ byTwp(4),
+ byFour(5),
+ byEight(6),
+ bySixteen(7),
+ byThirtyTwp(8)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Applicable for NVMe devices only. The PCIe link widths the device is capable of
+ supporting.
+ "
+ ::= { physicalDiskTableEntry 61 }
+
+physicalDiskCurrentActiveController OBJECT-TYPE
+ SYNTAX FQDDString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the Fully Qualified Device Descriptor (FQDD) of
+ the current active controller.
+ "
+ ::= { physicalDiskTableEntry 62 }
+
+physicalDiskFailoverController OBJECT-TYPE
+ SYNTAX FQDDString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the Fully Qualified Device Descriptor (FQDD) of
+ the failover controller.
+ "
+ ::= { physicalDiskTableEntry 63 }
+
+physicalDiskForeignKeyIdentifier OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Displays the encryption key identifier of the physical disk if it is in
+ locked or foreign state."
+
+ ::= { physicalDiskTableEntry 64 }
+
+
+
+-------------------------------------------------------------------------------
+-- Virtual Disk Table
+--
+-- OID Format:.1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.<a>.<i1>
+-------------------------------------------------------------------------------
+VirtualDiskTableEntry ::=SEQUENCE {
+ virtualDiskNumber INTEGER,
+ virtualDiskName DisplayString,
+ virtualDiskState INTEGER,
+ virtualDiskSizeInMB INTEGER,
+ virtualDiskWritePolicy INTEGER,
+ virtualDiskReadPolicy INTEGER,
+ virtualDiskLayout INTEGER,
+ virtualDiskStripeSize INTEGER,
+ virtualDiskComponentStatus ObjectStatusEnum,
+ virtualDiskBadBlocksDetected BooleanType,
+ virtualDiskSecured BooleanType,
+ virtualDiskIsCacheCade BooleanType,
+ virtualDiskDiskCachePolicy INTEGER,
+ virtualDiskOperationalState INTEGER,
+ virtualDiskProgress INTEGER,
+ virtualDiskAvailableProtocols DisplayString,
+ virtualDiskMediaType DisplayString,
+ virtualDiskRemainingRedundancy INTEGER,
+ virtualDiskFQDD FQDDString,
+ virtualDiskDisplayName DisplayString,
+ virtualDiskT10PIStatus INTEGER,
+ virtualDiskBlockSizeInBytes INTEGER,
+ virtualDiskAdapter1AccessPolicy INTEGER,
+ virtualDiskAdapter2AccessPolicy INTEGER,
+ virtualDiskAdapter3AccessPolicy INTEGER,
+ virtualDiskAdapter4AccessPolicy INTEGER,
+ virtualDiskCurrentActiveController FQDDString,
+ virtualDiskFailoverController FQDDString
+}
+
+virtualDiskTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF VirtualDiskTableEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A table of managed virtual disks. The number of entries is related
+ to number of virtual disks discovered in the system.
+ The maximum number of entries is implementation dependent.
+ Note: The properties in this table may not be applicable to all
+ entries.
+ "
+ ::= { logicalDevices 1 }
+
+virtualDiskTableEntry OBJECT-TYPE
+ SYNTAX VirtualDiskTableEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "An entry in the virtual disk table. A row in this table cannot be
+ created or deleted by SNMP operations on columns of the table.
+ "
+ INDEX { virtualDiskNumber }
+ ::= { virtualDiskTable 1 }
+
+virtualDiskNumber OBJECT-TYPE
+ SYNTAX INTEGER (1..100000000)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Instance number of this virtual disk entry.
+ "
+ ::= { virtualDiskTableEntry 1 }
+
+virtualDiskName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The virtual disk's label as entered by the user.
+ "
+ ::= { virtualDiskTableEntry 2 }
+
+virtualDiskState OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ unknown(1),
+ online(2),
+ failed(3),
+ degraded(4)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The current state of this virtual disk
+ (which includes any member physical disks.)
+ Possible states:
+ 1: The current state could not be determined.
+ 2: The virtual disk is operating normally or optimally.
+ 3: The virtual disk has encountered a failure. The data on disk
+ is lost or is about to be lost.
+ 4: The virtual disk encounterd a failure with one or all of the
+ constituent redundant physical disks. The data on the virtual
+ disk might no longer be fault tolerant.
+ "
+ ::= { virtualDiskTableEntry 4 }
+
+virtualDiskSizeInMB OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The size of the virtual disk in megabytes.
+ "
+ ::= { virtualDiskTableEntry 6 }
+
+virtualDiskWritePolicy OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ writeThrough(1),
+ writeBack(2),
+ writeBackForce(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The write policy used by the controller for write operations on
+ this virtual disk.
+ Possible values:
+ 1: Write Through.
+ 2: Write Back.
+ 3: Force Write Back.
+ "
+ ::= { virtualDiskTableEntry 10 }
+
+virtualDiskReadPolicy OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ noReadAhead(1),
+ readAhead(2),
+ adaptiveReadAhead(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The read policy used by the controller for read operations on
+ this virtual disk.
+ Possible values:
+ 1: No Read Ahead.
+ 2: Read Ahead.
+ 3: Adaptive Read Ahead.
+ "
+ ::= { virtualDiskTableEntry 11 }
+
+virtualDiskLayout OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ other(1),
+ r0(2),
+ r1(3),
+ r5(4),
+ r6(5),
+ r10(6),
+ r50(7),
+ r60(8),
+ concatRaid1(9),
+ concatRaid5(10)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The virtual disk's RAID type.
+ Possible values:
+ 1: Not one of the following
+ 2: RAID-0
+ 3: RAID-1
+ 4: RAID-5
+ 5: RAID-6
+ 6: RAID-10
+ 7: RAID-50
+ 8: RAID-60
+ 9: Concatenated RAID 1
+ 10: Concatenated RAID 5
+ "
+ ::= { virtualDiskTableEntry 13 }
+
+virtualDiskStripeSize OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ other(1),
+ default(2),
+ fiveHundredAndTwelvebytes(3),
+ oneKilobytes(4),
+ twoKilobytes(5),
+ fourKilobytes(6),
+ eightKilobytes(7),
+ sixteenKilobytes(8),
+ thirtyTwoKilobytes(9),
+ sixtyFourKilobytes(10),
+ oneTwentyEightKilobytes(11),
+ twoFiftySixKilobytes(12),
+ fiveOneTwoKilobytes(13),
+ oneMegabye(14),
+ twoMegabytes(15),
+ fourMegabytes(16),
+ eightMegabytes(17),
+ sixteenMegabytes(18)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The stripe size of this virtual disk.
+ Possible values:
+ 1: Not one of the following
+ 2: Default.
+ 3: 512 bytes
+ 4: 1 kB,
+ 5: 2 kB,
+ 6: 4 kB,
+ 7: 8 kB,
+ 8: 16 kB,
+ 9: 32 kB,
+ 10: 64 kB,
+ 11: 128 kB,
+ 12: 256 kB,
+ 13: 512 kB,
+ 14: 1 MB,
+ 15: 2 MB,
+ 16: 4 MB,
+ 17: 8 MB,
+ 18: 16 MB
+ "
+ ::= { virtualDiskTableEntry 14 }
+
+virtualDiskComponentStatus OBJECT-TYPE
+ SYNTAX ObjectStatusEnum
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The status of the virtual disk itself without the
+ propagation of any contained component status.
+ Possible values:
+ 1: Other.
+ 2: Unknown.
+ 3: OK.
+ 4: Non-critical .
+ 5: Critical.
+ 6: Non-recoverable.
+ "
+ ::= { virtualDiskTableEntry 20 }
+
+virtualDiskBadBlocksDetected OBJECT-TYPE
+ SYNTAX BooleanType
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates whether the virtual disk has bad blocks.
+ "
+ ::= { virtualDiskTableEntry 23 }
+
+virtualDiskSecured OBJECT-TYPE
+ SYNTAX BooleanType
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates whether the virtual disk is secured or not.
+ "
+ ::= { virtualDiskTableEntry 24 }
+
+virtualDiskIsCacheCade OBJECT-TYPE
+ SYNTAX BooleanType
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates whether the virtual disk is being used as a secondary
+ cache by the controller.
+ "
+ ::= { virtualDiskTableEntry 25 }
+
+virtualDiskDiskCachePolicy OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ enabled(1),
+ disabled(2),
+ defullt(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The cache policy of the physical disks that are
+ part of this virtual disk
+ Possible values:
+ 1: Enabled.
+ 2: Disabled.
+ 3: Default.
+ "
+ ::= { virtualDiskTableEntry 26 }
+
+virtualDiskOperationalState OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ notApplicable(1),
+ reconstructing(2),
+ resynching(3),
+ initializing(4),
+ backgroundInit(5)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The state of the virtual disk when there are progressive
+ operations ongoing.
+ Possible values:
+ 1: There is no active operation running.
+ 2: The virtual disk configuration has changed.
+ The physical disks included in the virtual disk are being
+ modified to support the new configuration.
+ 3: A Consistency Check (CC) is being performed
+ on the virtual disk.
+ 4: The virtual disk is being initialized.
+ 5: BackGround Initialization (BGI) is being performed
+ on the virtual disk.
+ "
+ ::= { virtualDiskTableEntry 30 }
+
+virtualDiskProgress OBJECT-TYPE
+ SYNTAX INTEGER (0..100)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The progress percentage of the operation that is being
+ performed on the virtual disk. This is applicable
+ only if there is a progressive operations ongoing
+ "
+ ::= { virtualDiskTableEntry 31 }
+
+virtualDiskAvailableProtocols OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "List of protocols support by physical disks part of this virtual
+ disk. For e.g. SAS for Serial Attached SCSI or SATA for
+ Serial Advanced Technology Attachment.
+ "
+ ::= { virtualDiskTableEntry 32 }
+
+virtualDiskMediaType OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "List of media types of the physical disks part of this virtual
+ disk. For e.g. HDD for Hard Disk Drive or SSD for Solid State Device.
+ "
+ ::= { virtualDiskTableEntry 33 }
+
+virtualDiskRemainingRedundancy OBJECT-TYPE
+ SYNTAX INTEGER (0..2)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of physical disks which can be lost before the
+ virtual disk loses its redundancy.
+ "
+ ::= { virtualDiskTableEntry 34 }
+
+virtualDiskFQDD OBJECT-TYPE
+ SYNTAX FQDDString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The virtual disk's Fully Qualified Device Descriptor (FQDD) as
+ represented in Storage Management.
+ "
+ ::= { virtualDiskTableEntry 35 }
+
+virtualDiskDisplayName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The virtual disk's friendly FQDD as represented in Storage
+ Management.
+ "
+ ::= { virtualDiskTableEntry 36 }
+
+virtualDiskT10PIStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ other(1),
+ enabled(2),
+ disabled(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates whether the virtual disk supports the T10 PI (Protection
+ Information). These protection fields are known as DIF
+ (Data Integrity Fields).
+ Possible values:
+ 1: Not one of the following.
+ 2: Enabled.
+ 3: Disabled.
+ "
+ ::= { virtualDiskTableEntry 37 }
+
+virtualDiskBlockSizeInBytes OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The block size (in bytes) of the physical disk part of the virtual disk.
+ Possible values:
+ 1: 512.
+ 2: 4096
+ "
+ ::= { virtualDiskTableEntry 38 }
+
+virtualDiskAdapter1AccessPolicy OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ noAccess (1),
+ fullAccess (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the access policy of the virtual disk with the virtual
+ adapters.
+ Possible values:
+ 1: No Access.
+ 2: Full Access
+ "
+ ::= { virtualDiskTableEntry 39 }
+
+virtualDiskAdapter2AccessPolicy OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ noAccess (1),
+ fullAccess (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the access policy of the virtual disk with the virtual
+ adapters.
+ Possible values:
+ 1: No Access.
+ 2: Full Access
+ "
+ ::= { virtualDiskTableEntry 40 }
+
+virtualDiskAdapter3AccessPolicy OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ noAccess (1),
+ fullAccess (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the access policy of the virtual disk with the virtual
+ adapters.
+ Possible values:
+ 1: No Access.
+ 2: Full Access
+ "
+ ::= { virtualDiskTableEntry 41 }
+
+virtualDiskAdapter4AccessPolicy OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ noAccess (1),
+ fullAccess (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the access policy of the virtual disk with the virtual
+ adapters.
+ Possible values:
+ 1: No Access.
+ 2: Full Access
+ "
+ ::= { virtualDiskTableEntry 42 }
+
+virtualDiskCurrentActiveController OBJECT-TYPE
+ SYNTAX FQDDString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the Fully Qualified Device Descriptor (FQDD) of
+ the current active controller.
+ "
+ ::= { virtualDiskTableEntry 43 }
+
+virtualDiskFailoverController OBJECT-TYPE
+ SYNTAX FQDDString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the Fully Qualified Device Descriptor (FQDD) of
+ the failover controller.
+ "
+ ::= { virtualDiskTableEntry 44 }
+
+
+-------------------------------------------------------------------------------
+-- Enclosure Table
+--
+-- OID Format:.1.3.6.1.4.1.674.10892.2.6.1.20.130.3.1.<a>.<i1>
+-------------------------------------------------------------------------------
+
+EnclosureTableEntry ::=SEQUENCE {
+ enclosureNumber INTEGER,
+ enclosureName DisplayString,
+ enclosureState INTEGER,
+ enclosureServiceTag DisplayString,
+ enclosureAssetTag DisplayString,
+ enclosureConnectedPort DisplayString,
+ enclosureRollUpStatus ObjectStatusEnum,
+ enclosureComponentStatus ObjectStatusEnum,
+ enclosureFirmwareVersion DisplayString,
+ enclosureSASAddress DisplayString,
+ enclosureDriveCount INTEGER,
+ enclosureTotalSlots INTEGER,
+ enclosureFanCount DisplayString,
+ enclosurePSUCount DisplayString,
+ enclosureEMMCount DisplayString,
+ enclosureTempProbeCount DisplayString,
+ enclosureRedundantPath DisplayString,
+ enclosurePosition DisplayString,
+ enclosureBackplaneBayID DisplayString,
+ enclosureFQDD FQDDString,
+ enclosureDisplayName DisplayString,
+ enclosureType INTEGER
+}
+
+enclosureTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EnclosureTableEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A table of managed enclosures/backplanes. The number of entries is
+ related to number of internal backplane(s) discovered in the system
+ and external storage enclosure(s) attached to the system..
+ The maximum number of entries is implementation dependent.
+ Note: The properties in this table may not be applicable to all
+ entries.
+ "
+ ::= { physicalDevices 3 }
+
+enclosureTableEntry OBJECT-TYPE
+ SYNTAX EnclosureTableEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "An entry in the enclosure table. A row in this table cannot be
+ created or deleted by SNMP operations on columns of the table.
+ "
+ INDEX { enclosureNumber }
+ ::= { enclosureTable 1 }
+
+enclosureNumber OBJECT-TYPE
+ SYNTAX INTEGER (1..255)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Instance number of this enclossre/backplane.
+ "
+ ::= { enclosureTableEntry 1 }
+
+enclosureName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The enclosure/backplane's name as represented in Storage Management.
+ "
+ ::= { enclosureTableEntry 2 }
+
+enclosureState OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ unknown(1),
+ ready(2),
+ failed(3),
+ missing(4),
+ degraded(5),
+ foreign(6),
+ offline(7),
+ online(8),
+ blocked(9)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The current state of this enclosure/backplane.
+ Possible states:
+ 1: The current state could not be determined.
+ 2: The enclosure is operating normally.
+ 3: The enclosure has encountered a hardware problem or is not
+ responding.
+ 4: The enclosure is no longer connected to the controller or
+ there exists a problem communicating to the enclosure.
+ 5: The enclosure is unstable.
+ 6: The enclosure is inactive due to being configured by another
+ controller.
+ 7: The enclosure is offline and inaccessible.
+ 8: The enclosure is online and accessible.
+ 9: The enclosure is currently blocked by another controller.
+ "
+ ::= { enclosureTableEntry 4 }
+
+enclosureServiceTag OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Enclosure identification used when consulting customer support.
+ "
+ ::= { enclosureTableEntry 8 }
+
+enclosureAssetTag OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The asset tag information for the enclosure."
+ ::= { enclosureTableEntry 9 }
+
+enclosureConnectedPort OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The port on the controller to which the
+ storage enclosure is connected.
+ "
+ ::= { enclosureTableEntry 19 }
+
+enclosureRollUpStatus OBJECT-TYPE
+ SYNTAX ObjectStatusEnum
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Severity of the enclosure/backplane state.
+ This is the combined status of the enclosure and its sub-components.
+ Possible values:
+ 1: Other.
+ 2: Unknown.
+ 3: OK.
+ 4: Non-critical.
+ 5: Critical.
+ 6: Non-recoverable.
+ "
+ ::= { enclosureTableEntry 23 }
+
+enclosureComponentStatus OBJECT-TYPE
+ SYNTAX ObjectStatusEnum
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The status of the enclosure/backplane.itself without the
+ propagation of any contained component status.
+ Possible values:
+ 1: Other.
+ 2: Unknown.
+ 3: OK.
+ 4: Non-critical .
+ 5: Critical.
+ 6: Non-recoverable.
+ "
+ ::= { enclosureTableEntry 24 }
+
+enclosureFirmwareVersion OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The firmware information for the enclosure/backplane.
+ "
+ ::= { enclosureTableEntry 26 }
+
+enclosureSASAddress OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The SAS address of the enclosure/backplane.
+ "
+ ::= { enclosureTableEntry 30 }
+
+enclosureDriveCount OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of disks present in the enclosure/backplane.
+ "
+ ::= { enclosureTableEntry 31 }
+
+enclosureTotalSlots OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The total physical drive slots in a storage enclosure
+ or server backplane.
+ "
+ ::= { enclosureTableEntry 32 }
+
+enclosureFanCount OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of fans present in the storage enclosure.
+ "
+ ::= { enclosureTableEntry 40 }
+
+enclosurePSUCount OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of Power Supply Units (PSU) present
+ in the storage enclosure.
+ "
+ ::= { enclosureTableEntry 41 }
+
+enclosureEMMCount OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of Enclosure Management Modules (EMM)
+ present in the storage enclosure.
+ "
+ ::= { enclosureTableEntry 42 }
+
+enclosureTempProbeCount OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of temperature sensing devices
+ present in the storage enclosure.
+ "
+ ::= { enclosureTableEntry 43 }
+
+enclosureRedundantPath OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates whether the controller has multiply paths to
+ reach the storage enclosure.
+ "
+ ::= { enclosureTableEntry 44 }
+
+enclosurePosition OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The possition of the storage enclosure within a daisy chain.
+ "
+ ::= { enclosureTableEntry 45 }
+
+enclosureBackplaneBayID OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The unique bay ID of the backplane.
+ "
+ ::= { enclosureTableEntry 46 }
+
+enclosureFQDD OBJECT-TYPE
+ SYNTAX FQDDString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The enclosure/backplane's Fully Qualified Device Descriptor (FQDD)
+ as represented in Storage Management.
+ "
+ ::= { enclosureTableEntry 47 }
+
+enclosureDisplayName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The enclosure/backplane's friendly FQDD as represented in
+ Storage Management.
+ "
+ ::= { enclosureTableEntry 48 }
+
+enclosureType OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ other(1),
+ notApplicable(2),
+ sassata(3),
+ pcie(4),
+ universal(5)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The protocol supported by the backplane.
+ Possible states:
+ 1: Not one of the following or could not be determined.
+ 2: Not applicable (i.e. object is not a backplane).
+ 3: Supports SAS/SATA.
+ 4: Supports PCIe.
+ 5: Both SAS/SATA and PCIe.
+ "
+ ::= { enclosureTableEntry 49 }
+
+
+-------------------------------------------------------------------------------
+-- Enclosure Management Module Table
+--
+-- OID Format:.1.3.6.1.4.1.674.10892.2.6.1.20.130.13.1.<a>.<i1>
+-------------------------------------------------------------------------------
+
+EnclosureManagementModuleTableEntry ::=SEQUENCE {
+ enclosureManagementModuleNumber INTEGER,
+ enclosureManagementModuleName DisplayString,
+ enclosureManagementModuleState INTEGER,
+ enclosureManagementModulePartNumber DisplayString,
+ enclosureManagementModuleFWVersion DisplayString,
+ enclosureManagementModuleComponentStatus ObjectStatusEnum,
+ enclosureManagementModuleFQDD FQDDString,
+ enclosureManagementModuleDisplayName DisplayString
+}
+
+enclosureManagementModuleTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EnclosureManagementModuleTableEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A table of managed Enclosure Management Modules (EMM)
+ in the external storage enclosure(s). The number of
+ entries is related to number of enclosure management modules
+ discovered in the enclosure(s). The maximum number of entries
+ is implementation dependent.
+ Note: The properties in this table may not be applicable to all
+ entries.
+ "
+ ::= { physicalDevices 13 }
+
+enclosureManagementModuleTableEntry OBJECT-TYPE
+ SYNTAX EnclosureManagementModuleTableEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "An entry in the enclosure management module table. A row in
+ this table cannot be created or deleted by SNMP operations
+ on columns of the table.
+ "
+ INDEX { enclosureManagementModuleNumber }
+ ::= { enclosureManagementModuleTable 1 }
+
+enclosureManagementModuleNumber OBJECT-TYPE
+ SYNTAX INTEGER (1..255)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Instance number of this enclosure management module.
+ "
+ ::= { enclosureManagementModuleTableEntry 1 }
+
+enclosureManagementModuleName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The enclosure management module's name as
+ represented in Storage Management.
+ "
+ ::= { enclosureManagementModuleTableEntry 2 }
+
+enclosureManagementModuleState OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ unknown(1),
+ ready(2),
+ failed(3),
+ missing(4),
+ degraded(5)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The current state of this enclosure management module.
+ Possible states:
+ 1: The current state could not be determined.
+ 2: The enclosure management module is operating normally.
+ 3: The enclosure management module has encountered a
+ hardware problem or is not responding.
+ 4: The enclosure management module is no longer connected
+ to the enclosure or there exists a problem communicating to it.
+ 5: The enclosure management module is unstable.
+ "
+ ::= { enclosureManagementModuleTableEntry 4 }
+
+enclosureManagementModulePartNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The part number of the enclosure management module.
+ "
+ ::= { enclosureManagementModuleTableEntry 6 }
+
+enclosureManagementModuleFWVersion OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Firmware version of the enclosure management module.
+ "
+ ::= { enclosureManagementModuleTableEntry 8 }
+
+enclosureManagementModuleComponentStatus OBJECT-TYPE
+ SYNTAX ObjectStatusEnum
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The status of the enclosure management module.itself without the
+ propagation of any contained component status.
+ Possible values:
+ 1: Other.
+ 2: Unknown.
+ 3: OK.
+ 4: Non-critical .
+ 5: Critical.
+ 6: Non-recoverable.
+ "
+ ::= { enclosureManagementModuleTableEntry 11 }
+
+enclosureManagementModuleFQDD OBJECT-TYPE
+ SYNTAX FQDDString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The enclosure management module's Fully Qualified Device
+ Descriptor (FQDD) as represented in Storage Management.
+ "
+ ::= { enclosureManagementModuleTableEntry 15 }
+
+enclosureManagementModuleDisplayName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The enclosure management module's friendly FQDD as represented in
+ Storage Management.
+ "
+ ::= { enclosureManagementModuleTableEntry 16 }
+
+
+
+-------------------------------------------------------------------------------
+-- Enclosure Fan Table
+--
+-- OID Format:.1.3.6.1.4.1.674.10892.2.6.1.20.130.7.1.<a>.<i1>
+-------------------------------------------------------------------------------
+
+EnclosureFanTableEntry ::=SEQUENCE {
+ enclosureFanNumber INTEGER,
+ enclosureFanName DisplayString,
+ enclosureFanState INTEGER,
+ enclosureFanSpeed INTEGER,
+ enclosureFanComponentStatus ObjectStatusEnum,
+ enclosureFanFQDD FQDDString,
+ enclosureFanDisplayName DisplayString
+}
+
+enclosureFanTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EnclosureFanTableEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A table of managed fans in the external storage enclosure(s).
+ The number of entries is related to number of fans discovered in
+ the enclosure(s). The maximum number of entries is implementation
+ dependent.
+ Note: The properties in this table may not be applicable to all
+ entries.
+ "
+ ::= { physicalDevices 7 }
+
+enclosureFanTableEntry OBJECT-TYPE
+ SYNTAX EnclosureFanTableEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "An entry in the fan table. A row in this table cannot be
+ created or deleted by SNMP operations on columns of the table.
+ "
+ INDEX { enclosureFanNumber }
+ ::= { enclosureFanTable 1 }
+
+enclosureFanNumber OBJECT-TYPE
+ SYNTAX INTEGER (1..255)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Instance number of this fan.
+ "
+ ::= { enclosureFanTableEntry 1 }
+
+enclosureFanName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The fan's name as represented in Storage Management.
+ "
+ ::= { enclosureFanTableEntry 2 }
+
+enclosureFanState OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ unknown(1),
+ ready(2),
+ failed(3),
+ missing(4),
+ degraded(5)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The current state of this fan.
+ Possible states:
+ 1: The current state could not be determined.
+ 2: The fan is operating normally.
+ 3: The fan has encountered a hardware problem or is not
+ responding.
+ 4: The fan is no longer connected to the enclosure or
+ there exists a problem communicating to it.
+ 5: The fan is unstable.
+ "
+ ::= { enclosureFanTableEntry 4 }
+
+enclosureFanSpeed OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the current relative speed of the fan in RPMs.
+ "
+ ::= { enclosureFanTableEntry 11 }
+
+enclosureFanComponentStatus OBJECT-TYPE
+ SYNTAX ObjectStatusEnum
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The status of the fan itself without the
+ propagation of any contained component status.
+ Possible values:
+ 1: Other.
+ 2: Unknown.
+ 3: OK.
+ 4: Non-critical .
+ 5: Critical.
+ 6: Non-recoverable.
+ "
+ ::= { enclosureFanTableEntry 15 }
+
+enclosureFanFQDD OBJECT-TYPE
+ SYNTAX FQDDString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The fan's Fully Qualified Device Descriptor (FQDD)
+ as represented in Storage Management.
+ "
+ ::= { enclosureFanTableEntry 20 }
+
+enclosureFanDisplayName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The fan's friendly FQDD as represented in
+ Storage Management.
+ "
+ ::= { enclosureFanTableEntry 21 }
+
+
+
+
+-------------------------------------------------------------------------------
+-- Enclosure Power Supply Table
+--
+-- OID Format:.1.3.6.1.4.1.674.10892.2.6.1.20.130.9.1.<a>.<i1>
+-------------------------------------------------------------------------------
+EnclosurePowerSupplyTableEntry ::=SEQUENCE {
+ enclosurePowerSupplyNumber INTEGER,
+ enclosurePowerSupplyName DisplayString,
+ enclosurePowerSupplyState INTEGER,
+ enclosurePowerSupplyPartNumber DisplayString,
+ enclosurePowerSupplyComponentStatus ObjectStatusEnum,
+ enclosurePowerSupplyFQDD FQDDString,
+ enclosurePowerSupplyDisplayName DisplayString
+}
+
+enclosurePowerSupplyTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EnclosurePowerSupplyTableEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A table of managed Power Supply Units(PSU) in the external
+ storage enclosure(s). The number of entries is related to number
+ of power supply unit(s) discovered in the enclosure(s). The
+ maximum number of entries is implementation
+ dependent.
+ Note: The properties in this table may not be applicable to all
+ entries.
+ "
+ ::= { physicalDevices 9 }
+
+enclosurePowerSupplyTableEntry OBJECT-TYPE
+ SYNTAX EnclosurePowerSupplyTableEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "An entry in the power supply unit table. A row in this table cannot
+ be created or deleted by SNMP operations on columns of the table.
+ "
+ INDEX { enclosurePowerSupplyNumber }
+ ::= { enclosurePowerSupplyTable 1 }
+
+enclosurePowerSupplyNumber OBJECT-TYPE
+ SYNTAX INTEGER (1..255)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Instance number of this power supply unit.
+ "
+ ::= { enclosurePowerSupplyTableEntry 1 }
+
+enclosurePowerSupplyName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The power supply unit's name as represented in
+ Storage Management.
+ "
+ ::= { enclosurePowerSupplyTableEntry 2 }
+
+enclosurePowerSupplyState OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ unknown(1),
+ ready(2),
+ failed(3),
+ missing(4),
+ degraded(5)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The current state of this power supply unit.
+ Possible states:
+ 1: The current state could not be determined.
+ 2: The power supply unit is operating normally.
+ 3: The power supply unit has encountered a hardware problem
+ or is not responding.
+ 4: The power supply unit is no longer connected to the enclosure
+ or there exists a problem communicating to it.
+ 5: The power supply unit is unstable.
+ "
+ ::= { enclosurePowerSupplyTableEntry 4 }
+
+enclosurePowerSupplyPartNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The part number of the power supply unit.
+ "
+ ::= { enclosurePowerSupplyTableEntry 7 }
+
+enclosurePowerSupplyComponentStatus OBJECT-TYPE
+ SYNTAX ObjectStatusEnum
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The status of the power supply unit itself without the
+ propagation of any contained component status.
+ Possible values:
+ 1: Other.
+ 2: Unknown.
+ 3: OK.
+ 4: Non-critical .
+ 5: Critical.
+ 6: Non-recoverable.
+ "
+ ::= { enclosurePowerSupplyTableEntry 9 }
+
+enclosurePowerSupplyFQDD OBJECT-TYPE
+ SYNTAX FQDDString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The power supply unit's Fully Qualified Device Descriptor (FQDD)
+ as represented in Storage Management.
+ "
+ ::= { enclosurePowerSupplyTableEntry 15 }
+
+enclosurePowerSupplyDisplayName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The power supply unit's friendly FQDD as represented in
+ Storage Management.
+ "
+ ::= { enclosurePowerSupplyTableEntry 16 }
+
+
+-------------------------------------------------------------------------------
+-- Enclosure Temperature Probe Table
+--
+-- OID Format:.1.3.6.1.4.1.674.10892.2.6.1.20.130.11.1.<a>.<i1>
+-------------------------------------------------------------------------------
+EnclosureTemperatureProbeTableEntry ::=SEQUENCE {
+ enclosureTemperatureProbeNumber INTEGER,
+ enclosureTemperatureProbeName DisplayString,
+ enclosureTemperatureProbeState INTEGER,
+ enclosureTemperatureProbeMinWarningValue INTEGER,
+ enclosureTemperatureProbeMinCriticalValue INTEGER,
+ enclosureTemperatureProbeMaxWarningValue INTEGER,
+ enclosureTemperatureProbeMaxCriticalValue INTEGER,
+ enclosureTemperatureProbeCurValue INTEGER,
+ enclosureTemperatureProbeComponentStatus ObjectStatusEnum,
+ enclosureTemperatureProbeFQDD FQDDString,
+ enclosureTemperatureProbeDisplayName DisplayString
+}
+
+enclosureTemperatureProbeTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EnclosureTemperatureProbeTableEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A table of managed temperature probes in the external storage
+ enclosure(s). The number of entries is related to number of
+ temperature probes discovered in the enclosure(s). The maximum
+ number of entries is implementation dependent.
+ Note: The properties in this table may not be applicable to all
+ entries.
+ "
+ ::= { physicalDevices 11 }
+
+enclosureTemperatureProbeTableEntry OBJECT-TYPE
+ SYNTAX EnclosureTemperatureProbeTableEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "An entry in the temperature probe table. A row in this table cannot be
+ created or deleted by SNMP operations on columns of the table.
+ "
+ INDEX { enclosureTemperatureProbeNumber }
+ ::= { enclosureTemperatureProbeTable 1 }
+
+enclosureTemperatureProbeNumber OBJECT-TYPE
+ SYNTAX INTEGER (1..255)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Instance number of this temperature probe.
+ "
+ ::= { enclosureTemperatureProbeTableEntry 1 }
+
+enclosureTemperatureProbeName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The temperature probe's name as represented in
+ Storage Management.
+ "
+ ::= { enclosureTemperatureProbeTableEntry 2 }
+
+enclosureTemperatureProbeState OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ unknown(1),
+ ready(2),
+ failed(3),
+ missing(4),
+ degraded(5),
+ overWarning(6),
+ underWarning(7)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The current state of this temperature probe.
+ Possible states:
+ 1: The current state could not be determined.
+ 2: The temperature probe is operating normally.
+ 3: The temperature probe has encountered a hardware problem
+ or is not responding.
+ 4: The temperature probe is no longer connected to the enclosure
+ or there exists a problem communicating to it.
+ 5: The temperature probe is unstable.
+ 6: The temperature probe is Over Warning Temperature.
+ 7: The temperature probe is Under Warning Temperature.
+ "
+ ::= { enclosureTemperatureProbeTableEntry 4 }
+
+enclosureTemperatureProbeMinWarningValue OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The minimum temperature that will force the probe into
+ a warning state.
+ "
+ ::= { enclosureTemperatureProbeTableEntry 7 }
+
+enclosureTemperatureProbeMinCriticalValue OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The minimum temperature that will force the probe into
+ a error state.
+ "
+ ::= { enclosureTemperatureProbeTableEntry 8 }
+
+enclosureTemperatureProbeMaxWarningValue OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The maximum temperature that will force the probe into
+ a warning state.
+ "
+ ::= { enclosureTemperatureProbeTableEntry 9 }
+
+enclosureTemperatureProbeMaxCriticalValue OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The maximum temperature that will force the probe into
+ a warning state.
+ "
+ ::= { enclosureTemperatureProbeTableEntry 10 }
+
+enclosureTemperatureProbeCurValue OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The maximum temperature that will force the probe into
+ a warning state.
+ "
+ ::= { enclosureTemperatureProbeTableEntry 11 }
+
+enclosureTemperatureProbeComponentStatus OBJECT-TYPE
+ SYNTAX ObjectStatusEnum
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The status of the enclosure management module.itself without the
+ propagation of any contained component status.
+ Possible values:
+ 1: Other.
+ 2: Unknown.
+ 3: OK.
+ 4: Non-critical .
+ 5: Critical.
+ 6: Non-recoverable.
+ "
+ ::= { enclosureTemperatureProbeTableEntry 13 }
+
+enclosureTemperatureProbeFQDD OBJECT-TYPE
+ SYNTAX FQDDString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The temperature probe's Fully Qualified Device Descriptor (FQDD)
+ as represented in Storage Management.
+ "
+ ::= { enclosureTemperatureProbeTableEntry 15 }
+
+enclosureTemperatureProbeDisplayName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The temperature probe's friendly FQDD as represented
+ in Storage Management.
+ "
+ ::= { enclosureTemperatureProbeTableEntry 16 }
+
+
+ -------------------------------------------------------------------------------
+ -- group: Chassis Alerts 1
+ -------------------------------------------------------------------------------
+
+ drsCASubSystem OBJECT-TYPE
+ SYNTAX DellString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0020.0010.0001 This attribute defines the Sub-System Name of the CMC Alert"
+ ::= { drsChassisAlertVariables 1 }
+
+ drsCASSCurrStatus OBJECT-TYPE
+ SYNTAX DellStatus
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0020.0010.0002 This attribute defines the Current Status of the Alerting
+ Sub-System"
+ ::= { drsChassisAlertVariables 2 }
+
+ drsCASSPrevStatus OBJECT-TYPE
+ SYNTAX DellStatus
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0020.0010.0003 This attribute defines the Previous Status of the Alerting
+ Sub-System"
+ ::= { drsChassisAlertVariables 3 }
+
+ drsCASSChangeTime OBJECT-TYPE
+ SYNTAX TimeTicks
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0020.0010.0004 This attribute defines the Timestamp of Most Recent Change of
+ the Alerting Sub-System"
+ ::= { drsChassisAlertVariables 4 }
+
+ drsCAMessage OBJECT-TYPE
+ SYNTAX DellString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "0020.0010.0005 This attribute defines the CSSD message of the CMC Alert"
+ ::= { drsChassisAlertVariables 5 }
+
+ alertCMCTestTrap TRAP-TYPE
+ ENTERPRISE drsOutofBandGroup
+ DESCRIPTION "The CMC has generated a test trap"
+ --#TYPE "CMC Test Trap"
+ --#SUMMARY "CMC Test Trap"
+ --#SEVERITY INFORMATIONAL
+ --#CATEGORY Error Events
+ ::= 2000
+
+ alertCMCNormalTrap TRAP-TYPE
+ ENTERPRISE drsOutofBandGroup
+ VARIABLES { drsProductChassisName,
+ drsProductChassisLocation,
+ drsGlobalCurrStatus,
+ drsCASubSystem,
+ drsCASSCurrStatus,
+ drsCASSPrevStatus,
+ drsCASSChangeTime,
+ drsCAMessage }
+ DESCRIPTION "The CMC reported a return-to-normal or informational event."
+ --#TYPE "CMC Return-to-Normal / Informational Trap"
+ --#SUMMARY "Return-to-Normal / Informational Trap from CMC in system %s in location %s, message: %s"
+ --#ARGUMENTS {0,1,7}
+ --#SEVERITY NORMAL
+ --#CATEGORY Error Events
+ ::= 2002
+
+ alertCMCWarningTrap TRAP-TYPE
+ ENTERPRISE drsOutofBandGroup
+ VARIABLES { drsProductChassisName,
+ drsProductChassisLocation,
+ drsGlobalCurrStatus,
+ drsCASubSystem,
+ drsCASSCurrStatus,
+ drsCASSPrevStatus,
+ drsCASSChangeTime,
+ drsCAMessage }
+ DESCRIPTION "The CMC reported a warning event."
+ --#TYPE "CMC Warning Trap"
+ --#SUMMARY "Warning Trap from CMC in system %s in location %s, message: %s"
+ --#ARGUMENTS {0,1,7}
+ --#SEVERITY WARNING
+ --#CATEGORY Error Events
+ ::= 2003
+
+ alertCMCCriticalTrap TRAP-TYPE
+ ENTERPRISE drsOutofBandGroup
+ VARIABLES { drsProductChassisName,
+ drsProductChassisLocation,
+ drsGlobalCurrStatus,
+ drsCASubSystem,
+ drsCASSCurrStatus,
+ drsCASSPrevStatus,
+ drsCASSChangeTime,
+ drsCAMessage }
+ DESCRIPTION "The CMC reported a critical event."
+ --#TYPE "CMC Critical Trap"
+ --#SUMMARY "Critical Trap from CMC in system %s in location %s, message: %s"
+ --#ARGUMENTS {0,1,7}
+ --#SEVERITY CRITICAL
+ --#CATEGORY Error Events
+ ::= 2004
+
+ alertCMCNonRecoverableTrap TRAP-TYPE
+ ENTERPRISE drsOutofBandGroup
+ VARIABLES { drsProductChassisName,
+ drsProductChassisLocation,
+ drsGlobalCurrStatus,
+ drsCASubSystem,
+ drsCASSCurrStatus,
+ drsCASSPrevStatus,
+ drsCASSChangeTime,
+ drsCAMessage }
+ DESCRIPTION "The CMC reported a catastrophic event."
+ --#TYPE "CMC Non-Recoverable Trap"
+ --#SUMMARY "Non-Recoverable Trap from CMC in system %s in location %s, message: %s"
+ --#ARGUMENTS {0,1,7}
+ --#SEVERITY NON-RECOVERABLE
+ --#CATEGORY Error Events
+ ::= 2005
+
+ -------------------------------------------------------------------------------
+ -- group: Chassis Alerts 2
+ -------------------------------------------------------------------------------
+
+ drsCA2MessageID OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..8))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "Message ID of the alert."
+ ::= { drsChassisAlert2Variables 1 }
+
+ drsCA2Message OBJECT-TYPE
+ SYNTAX DellString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "Message describing the alert."
+ ::= { drsChassisAlert2Variables 2 }
+
+ drsCA2MessageArgs OBJECT-TYPE
+ SYNTAX DellString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "Concatenated set of strings representing any message arguments
+ that were used to construct the alert message. Each message
+ argument string is enclosed in double quotes, and there is a
+ comma after the ending double quote of each message argument
+ string, except the last one. Any double quotes found within a
+ message argument string were preprocessed and changed to single
+ quotes."
+ ::= { drsChassisAlert2Variables 3 }
+
+ drsCA2AlertStatus OBJECT-TYPE
+ SYNTAX DellStatus
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "Status of the alert."
+ ::= { drsChassisAlert2Variables 4 }
+
+ drsCA2FQDD OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..512))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "Fully qualified device descriptor of device causing the alert."
+ ::= { drsChassisAlert2Variables 5 }
+
+ ------------------------------------------------------------------------------
+ -- Chassis Alerts 2: System: Amperage Probe Traps
+ --
+ -- Category: System/1
+ -- Subcategory: AMP/16
+ ------------------------------------------------------------------------------
+
+ alert2AmperageProbeNormal TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Current sensor reading is within range."
+ --#TYPE "System: Amperage Normal"
+ --#SEVERITY INFORMATIONAL
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Status Events"
+ --#STATE OPERATIONAL
+ --#STATUS MANDATORY
+ ::= 2179
+
+ alert2AmperageProbeWarning TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Current sensor has detected a warning value."
+ --#TYPE "System: Amperage Warning"
+ --#SEVERITY MINOR
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Status Events"
+ --#STATE DEGRADED
+ --#STATUS MANDATORY
+ ::= 2178
+
+ alert2AmperageProbeFailure TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Current sensor has detected a failure value."
+ --#TYPE "System: Amperage Failure"
+ --#SEVERITY CRITICAL
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Error Events"
+ --#STATE DEGRADED
+ --#STATUS MANDATORY
+ ::= 2177
+
+ ------------------------------------------------------------------------------
+ -- Chassis Alerts 2: System: Battery Traps
+ --
+ -- Category: System/1
+ -- Subcategory: BAT/22
+ ------------------------------------------------------------------------------
+
+ alert2BatteryNormal TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Battery state has returned to normal;
+ or battery presence had been detected."
+ --#TYPE "System: Battery Normal"
+ --#SEVERITY INFORMATIONAL
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Status Events"
+ --#STATE OPERATIONAL
+ --#STATUS MANDATORY
+ ::= 2227
+
+ alert2BatteryWarning TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Battery is low."
+ --#TYPE "System: Battery Warning"
+ --#SEVERITY MINOR
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Status Events"
+ --#STATE DEGRADED
+ --#STATUS MANDATORY
+ ::= 2226
+
+ alert2BatteryFailure TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Battery has failed or battery is absent."
+ --#TYPE "System: Battery Failure"
+ --#SEVERITY CRITICAL
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Error Events"
+ --#STATE DEGRADED
+ --#STATUS MANDATORY
+ ::= 2225
+
+ ------------------------------------------------------------------------------
+ -- Chassis Alerts 2: System: Cable Traps
+ --
+ -- Category: System/1
+ -- Subcategory: CBL/43
+ ------------------------------------------------------------------------------
+
+ alert2CableFailure TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Cable failure."
+ --#TYPE "System: Cable Failure"
+ --#SEVERITY CRITICAL
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Error Events"
+ --#STATE DEGRADED
+ --#STATUS MANDATORY
+ ::= 2393
+
+ ------------------------------------------------------------------------------
+ -- Chassis Alerts 2: System: CMC Traps
+ --
+ -- Category: System/1
+ -- Subcategory: CMC/62
+ ------------------------------------------------------------------------------
+
+ alert2CMCWarning TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Chassis Management Controller detected a warning."
+ --#TYPE "System: CMC Warning"
+ --#SEVERITY MINOR
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Status Events"
+ --#STATE DEGRADED
+ --#STATUS MANDATORY
+ ::= 2546
+
+ alert2CMCFailure TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Chassis Management Controller detected an error."
+ --#TYPE "System: CMC Failure"
+ --#SEVERITY CRITICAL
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Error Events"
+ --#STATE DEGRADED
+ --#STATUS MANDATORY
+ ::= 2545
+
+ ------------------------------------------------------------------------------
+ -- Chassis Alerts 2: System: Fan Traps
+ --
+ -- Category: System/1
+ -- Subcategory: FAN/13
+ ------------------------------------------------------------------------------
+
+ alert2FanInformation TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Fan information."
+ --#TYPE "System: Fan Information"
+ --#SEVERITY INFORMATIONAL
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Status Events"
+ --#STATE OPERATIONAL
+ --#STATUS MANDATORY
+ ::= 2155
+
+ alert2FanWarning TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Fan warning."
+ --#TYPE "System: Fan Warning"
+ --#SEVERITY MINOR
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Status Events"
+ --#STATE DEGRADED
+ --#STATUS MANDATORY
+ ::= 2154
+
+ alert2FanFailure TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Fan failure."
+ --#TYPE "System: Fan Failure"
+ --#SEVERITY CRITICAL
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Error Events"
+ --#STATE DEGRADED
+ --#STATUS MANDATORY
+ ::= 2153
+
+ ------------------------------------------------------------------------------
+ -- Chassis Alerts 2: System: Hardware Configuration Traps
+ --
+ -- Category: System/1
+ -- Subcategory: HWC/35
+ ------------------------------------------------------------------------------
+
+ alert2HardwareConfigurationInformation TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Hardware configuration information."
+ --#TYPE "System: Hardware Configuration Information"
+ --#SEVERITY INFORMATIONAL
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Status Events"
+ --#STATE OPERATIONAL
+ --#STATUS MANDATORY
+ ::= 2331
+
+ alert2HardwareConfigurationWarning TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Hardware configuration warning."
+ --#TYPE "System: Hardware Configuration Warning"
+ --#SEVERITY MINOR
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Status Events"
+ --#STATE DEGRADED
+ --#STATUS MANDATORY
+ ::= 2330
+
+ alert2HardwareConfigurationFailure TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Hardware configuration failure or critical event."
+ --#TYPE "System: Hardware Configuration Failure"
+ --#SEVERITY CRITICAL
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Error Events"
+ --#STATE DEGRADED
+ --#STATUS MANDATORY
+ ::= 2329
+
+ ------------------------------------------------------------------------------
+ -- Chassis Alerts 2: System: IO Virtualization Traps
+ --
+ -- Category: System/1
+ -- Subcategory: IOV/63
+ ------------------------------------------------------------------------------
+
+ alert2IOVirtualizationInformation TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "IO Virtualization information."
+ --#TYPE "System: IO Virtualization Information"
+ --#SEVERITY INFORMATIONAL
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Status Events"
+ --#STATE OPERATIONAL
+ --#STATUS MANDATORY
+ ::= 2555
+
+ alert2IOVirtualizationWarning TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "IO Virtualization warning."
+ --#TYPE "System: IO Virtualization Warning"
+ --#SEVERITY MINOR
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Status Events"
+ --#STATE DEGRADED
+ --#STATUS MANDATORY
+ ::= 2554
+
+ alert2IOVirtualizationFailure TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "IO Virtualization failure or critical event."
+ --#TYPE "System: IO Virtualization Failure"
+ --#SEVERITY CRITICAL
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Error Events"
+ --#STATE DEGRADED
+ --#STATUS MANDATORY
+ ::= 2553
+
+ ------------------------------------------------------------------------------
+ -- Chassis Alerts 2: System: Link Status Traps
+ --
+ -- Category: System/1
+ -- Subcategory: LNK/25
+ ------------------------------------------------------------------------------
+
+ alert2LinkStatusInformation TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Link status information."
+ --#TYPE "System: Link Status Information"
+ --#SEVERITY INFORMATIONAL
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Status Events"
+ --#STATE OPERATIONAL
+ --#STATUS MANDATORY
+ ::= 2251
+
+ alert2LinkStatusWarning TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Link status warning."
+ --#TYPE "System: Link Status Warning"
+ --#SEVERITY MINOR
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Status Events"
+ --#STATE DEGRADED
+ --#STATUS MANDATORY
+ ::= 2250
+
+ alert2LinkStatusFailure TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Link status failure or critical event."
+ --#TYPE "System: Link Status Failure"
+ --#SEVERITY CRITICAL
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Error Events"
+ --#STATE DEGRADED
+ --#STATUS MANDATORY
+ ::= 2249
+
+ ------------------------------------------------------------------------------
+ -- Chassis Alerts 2: System: PCI Device Traps
+ --
+ -- Category: System/1
+ -- Subcategory: PCI/46
+ ------------------------------------------------------------------------------
+
+ alert2PCIDeviceInformation TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "PCI device information."
+ --#TYPE "System: PCI Device Information"
+ --#SEVERITY INFORMATIONAL
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Status Events"
+ --#STATE OPERATIONAL
+ --#STATUS MANDATORY
+ ::= 2419
+
+ alert2PCIDeviceWarning TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "PCI device warning."
+ --#TYPE "System: PCI Device Warning"
+ --#SEVERITY MINOR
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Status Events"
+ --#STATE DEGRADED
+ --#STATUS MANDATORY
+ ::= 2418
+
+ alert2PCIDeviceFailure TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "PCI device failure or critical event."
+ --#TYPE "System: PCI Device Failure"
+ --#SEVERITY CRITICAL
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Error Events"
+ --#STATE DEGRADED
+ --#STATUS MANDATORY
+ ::= 2417
+
+ ------------------------------------------------------------------------------
+ -- Chassis Alerts 2: System: Power Supply Traps
+ --
+ -- Category: System/1
+ -- Subcategory: PSU/17
+ ------------------------------------------------------------------------------
+
+ alert2PowerSupplyNormal TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Power supply has returned to normal."
+ --#TYPE "System: Power Supply Normal"
+ --#SEVERITY INFORMATIONAL
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Status Events"
+ --#STATE OPERATIONAL
+ --#STATUS MANDATORY
+ ::= 2187
+
+ alert2PowerSupplyWarning TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Power supply has detected a warning."
+ --#TYPE "System: Power Supply Warning"
+ --#SEVERITY MINOR
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Status Events"
+ --#STATE DEGRADED
+ --#STATUS MANDATORY
+ ::= 2186
+
+ alert2PowerSupplyFailure TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Power supply has detected a failure."
+ --#TYPE "System: Power Supply Failure"
+ --#SEVERITY CRITICAL
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Error Events"
+ --#STATE DEGRADED
+ --#STATUS MANDATORY
+ ::= 2185
+
+ alert2PowerSupplyRedundancyPolicyChanged TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "PSU redundancy policy changed."
+ --#TYPE "System: Power Supply Redundancy policy changed"
+ --#SEVERITY INFORMATIONAL
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Status Events"
+ --#STATE OPERATIONAL
+ --#STATUS MANDATORY
+ ::= 8331
+
+ ------------------------------------------------------------------------------
+ -- Chassis Alerts 2: System: Power Supply Absent Traps
+ --
+ -- Category: System/1
+ -- Subcategory: PSUA/52
+ ------------------------------------------------------------------------------
+
+ alert2PowerSupplyAbsent TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Power supply is absent."
+ --#TYPE "System: Power Supply Absent"
+ --#SEVERITY CRITICAL
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Error Events"
+ --#STATE DEGRADED
+ --#STATUS MANDATORY
+ ::= 2465
+
+ ------------------------------------------------------------------------------
+ -- Chassis Alerts 2: System: Power Usage Traps
+ --
+ -- Category: System/1
+ -- Subcategory: PWR/28
+ ------------------------------------------------------------------------------
+
+ alert2PowerUsageInformation TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Power usage information."
+ --#TYPE "System: Power Usage Information"
+ --#SEVERITY INFORMATIONAL
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Status Events"
+ --#STATE OPERATIONAL
+ --#STATUS MANDATORY
+ ::= 2275
+
+ alert2PowerUsageWarning TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Power usage warning."
+ --#TYPE "System: Power Usage Warning"
+ --#SEVERITY MINOR
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Status Events"
+ --#STATE DEGRADED
+ --#STATUS MANDATORY
+ ::= 2274
+
+ alert2PowerUsageFailure TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Power usage failure."
+ --#TYPE "System: Power Usage Failure"
+ --#SEVERITY CRITICAL
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Error Events"
+ --#STATE DEGRADED
+ --#STATUS MANDATORY
+ ::= 2273
+
+ ------------------------------------------------------------------------------
+ -- Chassis Alerts 2: System: Redundancy Traps
+ --
+ -- Category: System/1
+ -- Subcategory: RDU/53
+ ------------------------------------------------------------------------------
+
+ alert2RedundancyInformation TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Redundancy information."
+ --#TYPE "System: Redundancy Information"
+ --#SEVERITY INFORMATIONAL
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Status Events"
+ --#STATE OPERATIONAL
+ --#STATUS MANDATORY
+ ::= 2475
+
+ alert2RedundancyDegraded TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Redundancy is degraded."
+ --#TYPE "System: Redundancy Degraded"
+ --#SEVERITY MINOR
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Status Events"
+ --#STATE DEGRADED
+ --#STATUS MANDATORY
+ ::= 2474
+
+ alert2RedundancyLost TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Redundancy is lost."
+ --#TYPE "System: Redundancy Lost"
+ --#SEVERITY CRITICAL
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Error Events"
+ --#STATE DEGRADED
+ --#STATUS MANDATORY
+ ::= 2473
+
+ ------------------------------------------------------------------------------
+ -- Chassis Alerts 2: System: Security Event Traps
+ --
+ -- Category: System/1
+ -- Subcategory: SEC/42
+ ------------------------------------------------------------------------------
+
+ alert2SecurityInformation TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Security information."
+ --#TYPE "System: Security Information"
+ --#SEVERITY INFORMATIONAL
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Status Events"
+ --#STATE OPERATIONAL
+ --#STATUS MANDATORY
+ ::= 2387
+
+ alert2SecurityWarning TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Security warning."
+ --#TYPE "System: Security Warning"
+ --#SEVERITY MINOR
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Status Events"
+ --#STATE OPERATIONAL
+ --#STATUS MANDATORY
+ ::= 2386
+
+ alert2SecurityFailure TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Security failure or critical event."
+ --#TYPE "System: Security Failure"
+ --#SEVERITY CRITICAL
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Error Events"
+ --#STATE OPERATIONAL
+ --#STATUS MANDATORY
+ ::= 2385
+
+ ------------------------------------------------------------------------------
+ -- Chassis Alerts 2: System: System Event Log Traps
+ --
+ -- Category: System/1
+ -- Subcategory: SEL/41
+ ------------------------------------------------------------------------------
+
+ alert2SystemEventLogInformation TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "System Event Log information."
+ --#TYPE "System: System Event Log Information"
+ --#SEVERITY INFORMATIONAL
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Status Events"
+ --#STATE OPERATIONAL
+ --#STATUS MANDATORY
+ ::= 2379
+
+ alert2SystemEventLogWarning TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "System Event Log warning."
+ --#TYPE "System: System Event Log Warning"
+ --#SEVERITY MINOR
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Status Events"
+ --#STATE DEGRADED
+ --#STATUS MANDATORY
+ ::= 2378
+
+ alert2SystemEventLogFailure TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "System Event Log failure or critical event."
+ --#TYPE "System: System Event Log Failure"
+ --#SEVERITY CRITICAL
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Error Events"
+ --#STATE OPERATIONAL
+ --#STATUS MANDATORY
+ ::= 2377
+
+ ------------------------------------------------------------------------------
+ -- Chassis Alerts 2: System: Software Configuration Traps
+ --
+ -- Category: System/1
+ -- Subcategory: SWC/36
+ ------------------------------------------------------------------------------
+
+ alert2SoftwareConfigurationInformation TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Software configuration information."
+ --#TYPE "System: Software Configuration Information"
+ --#SEVERITY INFORMATIONAL
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Status Events"
+ --#STATE OPERATIONAL
+ --#STATUS MANDATORY
+ ::= 2339
+
+ alert2SoftwareConfigurationWarning TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Software configuration warning."
+ --#TYPE "System: Software Configuration Warning"
+ --#SEVERITY MINOR
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Status Events"
+ --#STATE DEGRADED
+ --#STATUS MANDATORY
+ ::= 2338
+
+ alert2SoftwareConfigurationFailure TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Software configuration failure."
+ --#TYPE "System: Software Configuration Failure"
+ --#SEVERITY CRITICAL
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Error Events"
+ --#STATE DEGRADED
+ --#STATUS MANDATORY
+ ::= 2337
+
+ ------------------------------------------------------------------------------
+ -- Chassis Alerts 2: System: Temperature Probe Traps
+ --
+ -- Category: System/1
+ -- Subcategory: TMP/14
+ ------------------------------------------------------------------------------
+
+ alert2TemperatureProbeNormal TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Temperature sensor value is within range."
+ --#TYPE "System: Temperature Normal"
+ --#SEVERITY INFORMATIONAL
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Status Events"
+ --#STATE OPERATIONAL
+ --#STATUS MANDATORY
+ ::= 2163
+
+ alert2TemperatureProbeWarning TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Temperature sensor has detected a warning value."
+ --#TYPE "System: Temperature Warning"
+ --#SEVERITY MINOR
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Status Events"
+ --#STATE DEGRADED
+ --#STATUS MANDATORY
+ ::= 2162
+
+ alert2TemperatureProbeFailure TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Temperature sensor has detected a failure value."
+ --#TYPE "System: Temperature Failure"
+ --#SEVERITY CRITICAL
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Error Events"
+ --#STATE DEGRADED
+ --#STATUS MANDATORY
+ ::= 2161
+
+ alert2IOMTemperatureExceeded TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "I/O Module <iom slot name> temperature exceeded operating range."
+ --#TYPE "System: Temperature Failure"
+ --#SEVERITY CRITICAL
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Error Events"
+ --#STATE DEGRADED
+ --#STATUS MANDATORY
+ ::= 8305
+
+ alert2Unable2ReadTemperatureSensors TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Unable to read planar board temperature sensors. The cooling has been increased to safeguard the system."
+ --#TYPE "System: Temperature Failure"
+ --#SEVERITY MINOR
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Error Events"
+ --#STATE DEGRADED
+ --#STATUS MANDATORY
+ ::= 8306
+
+ ------------------------------------------------------------------------------
+ -- Chassis Alerts 2: System: Voltage Probe Traps
+ --
+ -- Category: System/1
+ -- Subcategory: VLT/15
+ ------------------------------------------------------------------------------
+
+ alert2VoltageProbeNormal TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Voltage sensor reading is within range."
+ --#TYPE "System: Voltage Normal"
+ --#SEVERITY INFORMATIONAL
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Status Events"
+ --#STATE OPERATIONAL
+ --#STATUS MANDATORY
+ ::= 2171
+
+ alert2VoltageProbeWarning TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Voltage sensor has detected a warning value."
+ --#TYPE "System: Voltage Warning"
+ --#SEVERITY MINOR
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Status Events"
+ --#STATE DEGRADED
+ --#STATUS MANDATORY
+ ::= 2170
+
+ alert2VoltageProbeFailure TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Voltage sensor has detected a failure value."
+ --#TYPE "System: Voltage Failure"
+ --#SEVERITY CRITICAL
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Error Events"
+ --#STATE DEGRADED
+ --#STATUS MANDATORY
+ ::= 2169
+
+ -------------------------------------------------------------------------------
+ -- Chassis Alerts 2: Storage: Battery Traps
+ --
+ -- Category: Storage/2
+ -- Subcategory: BAT/22
+ -------------------------------------------------------------------------------
+
+ alert2StorageBatteryInformation TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Storage Battery information."
+ --#TYPE "Storage: Battery Information"
+ --#SEVERITY INFORMATIONAL
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Error Events"
+ --#STATE OPERATIONAL
+ --#STATUS MANDATORY
+ ::= 4275
+
+ alert2StorageBatteryWarning TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Storage Battery warning."
+ --#TYPE "Storage: Battery Warning"
+ --#SEVERITY MINOR
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Error Events"
+ --#STATE DEGRADED
+ --#STATUS MANDATORY
+ ::= 4274
+
+ alert2StorageBatteryFailure TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Storage Battery failure."
+ --#TYPE "Storage: Battery Failure"
+ --#SEVERITY CRITICAL
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Error Events"
+ --#STATE FAILED
+ --#STATUS MANDATORY
+ ::= 4273
+
+ ------------------------------------------------------------------------------
+ -- Chassis Alerts 2: Storage: Controller Traps
+ --
+ -- Category: Storage/2
+ -- Subcategory: CTL/29
+ ------------------------------------------------------------------------------
+
+ alert2StorageControllerInformation TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Storage Controller information."
+ --#TYPE "Storage: Controller Information"
+ --#SEVERITY INFORMATIONAL
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Error Events"
+ --#STATE OPERATIONAL
+ --#STATUS MANDATORY
+ ::= 4331
+
+ alert2StorageControllerWarning TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Storage Controller warning."
+ --#TYPE "Storage: Controller Warning"
+ --#SEVERITY MINOR
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Error Events"
+ --#STATE DEGRADED
+ --#STATUS MANDATORY
+ ::= 4330
+
+ alert2StorageControllerFailure TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Storage Controller failure."
+ --#TYPE "Storage: Controller Failure"
+ --#SEVERITY CRITICAL
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Error Events"
+ --#STATE FAILED
+ --#STATUS MANDATORY
+ ::= 4329
+
+ ------------------------------------------------------------------------------
+ -- Chassis Alerts 2: Storage: Enclosure Traps
+ --
+ -- Category: Storage/2
+ -- Subcategory: ENC/30
+ ------------------------------------------------------------------------------
+
+ alert2StorageEnclosureInformation TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Storage Enclosure information."
+ --#TYPE "Storage: Enclosure Information"
+ --#SEVERITY INFORMATIONAL
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Error Events"
+ --#STATE OPERATIONAL
+ --#STATUS MANDATORY
+ ::= 4339
+
+ alert2StorageEnclosureWarning TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Storage Enclosure warning."
+ --#TYPE "Storage: Enclosure Warning"
+ --#SEVERITY MINOR
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Error Events"
+ --#STATE DEGRADED
+ --#STATUS MANDATORY
+ ::= 4338
+
+ alert2StorageEnclosureFailure TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Storage Enclosure failure."
+ --#TYPE "Storage: Enclosure Failure"
+ --#SEVERITY CRITICAL
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Error Events"
+ --#STATE FAILED
+ --#STATUS MANDATORY
+ ::= 4337
+
+ ------------------------------------------------------------------------------
+ -- Chassis Alerts 2: Storage: Fan Traps
+ --
+ -- Category: Storage/2
+ -- Subcategory: FAN/13
+ ------------------------------------------------------------------------------
+
+ alert2StorageFanInformation TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Storage Fan information."
+ --#TYPE "Storage: Fan Information"
+ --#SEVERITY INFORMATIONAL
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Error Events"
+ --#STATE OPERATIONAL
+ --#STATUS MANDATORY
+ ::= 4203
+
+ alert2StorageFanWarning TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Storage Fan warning."
+ --#TYPE "Storage: Fan Warning"
+ --#SEVERITY MINOR
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Status Events"
+ --#STATE DEGRADED
+ --#STATUS MANDATORY
+ ::= 4202
+
+ alert2StorageFanFailure TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Storage Fan failure."
+ --#TYPE "Storage: Fan Failure"
+ --#SEVERITY CRITICAL
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Error Events"
+ --#STATE FAILED
+ --#STATUS MANDATORY
+ ::= 4201
+
+ ------------------------------------------------------------------------------
+ -- Chassis Alerts 2: Storage: Physical Disk Traps
+ --
+ -- Category: Storage/2
+ -- Subcategory: PDR/31
+ ------------------------------------------------------------------------------
+
+ alert2StoragePhysicalDiskInformation TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Storage Physical disk information."
+ --#TYPE "Storage: Physical Disk Information"
+ --#SEVERITY INFORMATIONAL
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Error Events"
+ --#STATE OPERATIONAL
+ --#STATUS MANDATORY
+ ::= 4347
+
+ alert2StoragePhysicalDiskWarning TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Storage Physical disk warning."
+ --#TYPE "Storage: Physical Disk Warning"
+ --#SEVERITY MINOR
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Error Events"
+ --#STATE DEGRADED
+ --#STATUS MANDATORY
+ ::= 4346
+
+ alert2StoragePhysicalDiskFailure TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Storage Physical disk failure."
+ --#TYPE "Storage: Physical Disk Failure"
+ --#SEVERITY CRITICAL
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Error Events"
+ --#STATE FAILED
+ --#STATUS MANDATORY
+ ::= 4345
+
+ ------------------------------------------------------------------------------
+ -- Chassis Alerts 2: Storage: Power Supply Traps
+ --
+ -- Category: Storage/2
+ -- Subcategory: PSU/17
+ ------------------------------------------------------------------------------
+
+ alert2StoragePowerSupplyInformation TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Storage Power supply information."
+ --#TYPE "Storage: Power Supply Information"
+ --#SEVERITY INFORMATIONAL
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Error Events"
+ --#STATE OPERATIONAL
+ --#STATUS MANDATORY
+ ::= 4235
+
+ alert2StoragePowerSupplyWarning TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Storage Power supply warning."
+ --#TYPE "Storage: Power Supply Warning"
+ --#SEVERITY MINOR
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Error Events"
+ --#STATE DEGRADED
+ --#STATUS MANDATORY
+ ::= 4234
+
+ alert2StoragePowerSupplyFailure TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Storage Power supply failure."
+ --#TYPE "Storage: Power Supply Failure"
+ --#SEVERITY CRITICAL
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Error Events"
+ --#STATE FAILED
+ --#STATUS MANDATORY
+ ::= 4233
+
+ ------------------------------------------------------------------------------
+ -- Chassis Alerts 2: Storage: Security Event Traps
+ --
+ -- Category: Storage/2
+ -- Subcategory: SEC/42
+ ------------------------------------------------------------------------------
+
+ alert2StorageSecurityInformation TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Storage Security information."
+ --#TYPE "Storage: Security Information"
+ --#SEVERITY INFORMATIONAL
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Status Events"
+ --#STATE OPERATIONAL
+ --#STATUS MANDATORY
+ ::= 4435
+
+ alert2StorageSecurityWarning TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Storage Security warning."
+ --#TYPE "Storage: Security Warning"
+ --#SEVERITY MINOR
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Status Events"
+ --#STATE OPERATIONAL
+ --#STATUS MANDATORY
+ ::= 4434
+
+ alert2StorageSecurityFailure TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Storage Security failure or critical event."
+ --#TYPE "Storage: Security Failure"
+ --#SEVERITY CRITICAL
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Error Events"
+ --#STATE OPERATIONAL
+ --#STATUS MANDATORY
+ ::= 4433
+
+ ------------------------------------------------------------------------------
+ -- Chassis Alerts 2: Storage: Storage Management Status Traps
+ --
+ -- Category: Storage/2
+ -- Subcategory: STOR/10
+ ------------------------------------------------------------------------------
+
+ alert2StorageManagementInformation TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Storage Management information.
+ There is no global status change associated with this trap."
+ --#TYPE "Storage: Storage Management Information"
+ --#SEVERITY INFORMATIONAL
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Error Events"
+ --#STATE OPERATIONAL
+ --#STATUS MANDATORY
+ ::= 4179
+
+ alert2StorageManagementWarning TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Storage Management has detected a device independent warning
+ condition. There is no global status change associated with this
+ trap."
+ --#TYPE "Storage: Storage Management Warning"
+ --#SEVERITY MINOR
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Error Events"
+ --#STATE DEGRADED
+ --#STATUS MANDATORY
+ ::= 4178
+
+ alert2StorageManagementFailure TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Storage Management has detected a device independent error condition.
+ There is no global status change associated with this trap."
+ --#TYPE "Storage: Storage Management Failure"
+ --#SEVERITY CRITICAL
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Error Events"
+ --#STATE FAILED
+ --#STATUS MANDATORY
+ ::= 4177
+
+ ------------------------------------------------------------------------------
+ -- Chassis Alerts 2: Storage: Temperature Probe Traps
+ --
+ -- Category: Storage/2
+ -- Subcategory: TMP/14
+ ------------------------------------------------------------------------------
+
+ alert2StorageTemperatureProbeInformation TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Storage Temperature probe information."
+ --#TYPE "Storage: Temperature Probe Information"
+ --#SEVERITY INFORMATIONAL
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Error Events"
+ --#STATE OPERATIONAL
+ --#STATUS MANDATORY
+ ::= 4211
+
+ alert2StorageTemperatureProbeWarning TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Storage Temperature probe warning."
+ --#TYPE "Storage: Temperature Probe Warning"
+ --#SEVERITY MINOR
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Error Events"
+ --#STATE DEGRADED
+ --#STATUS MANDATORY
+ ::= 4210
+
+ alert2StorageTemperatureProbeFailure TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Storage Temperature probe failure."
+ --#TYPE "Storage: Temperature Probe Failure"
+ --#SEVERITY CRITICAL
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Error Events"
+ --#STATE FAILED
+ --#STATUS MANDATORY
+ ::= 4209
+
+ ------------------------------------------------------------------------------
+ -- Chassis Alerts 2: Storage: Virtual Disk Traps
+ --
+ -- Category: Storage/2
+ -- Subcategory: VDR/32
+ ------------------------------------------------------------------------------
+
+ alert2StorageVirtualDiskInformation TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Storage Virtual disk information."
+ --#TYPE "Storage: Virtual Disk Information"
+ --#SEVERITY INFORMATIONAL
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Error Events"
+ --#STATE OPERATIONAL
+ --#STATUS MANDATORY
+ ::= 4355
+
+ alert2StorageVirtualDiskWarning TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Storage Virtual disk warning."
+ --#TYPE "Storage: Virtual Disk Warning"
+ --#SEVERITY MINOR
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Error Events"
+ --#STATE DEGRADED
+ --#STATUS MANDATORY
+ ::= 4354
+
+ alert2StorageVirtualDiskFailure TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Storage Virtual disk failure."
+ --#TYPE "Storage: Virtual Disk Failure"
+ --#SEVERITY CRITICAL
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Error Events"
+ --#STATE FAILED
+ --#STATUS MANDATORY
+ ::= 4353
+
+ ------------------------------------------------------------------------------
+ -- Chassis Alerts 2: Updates: Software Change Traps
+ --
+ -- Category: Updates/3
+ -- Subcategory: SWU/21
+ ------------------------------------------------------------------------------
+
+ alert2SoftwareChangeUpdateWarning TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Software change update warning."
+ --#TYPE "Updates: Software Change Warning"
+ --#SEVERITY MINOR
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Status Events"
+ --#STATE DEGRADED
+ --#STATUS MANDATORY
+ ::= 6314
+
+ ------------------------------------------------------------------------------
+ -- Chassis Alerts 2: Audit: CMC Traps
+ --
+ -- Category: Audit/4
+ -- Subcategory: CMC/62
+ ------------------------------------------------------------------------------
+
+ alert2CMCAuditInformation TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Chassis Management Controller audit information."
+ --#TYPE "Audit: CMC Information"
+ --#SEVERITY INFORMATIONAL
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Status Events"
+ --#STATE OPERATIONAL
+ --#STATUS MANDATORY
+ ::= 8691
+
+ alert2CMCAuditWarning TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Chassis Management Controller audit warning."
+ --#TYPE "Audit: CMC Warning"
+ --#SEVERITY MINOR
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Status Events"
+ --#STATE DEGRADED
+ --#STATUS MANDATORY
+ ::= 8690
+
+ alert2CMCAuditFailure TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Chassis Management Controller audit failure or critical event."
+ --#TYPE "Audit: CMC Failure"
+ --#SEVERITY CRITICAL
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Error Events"
+ --#STATE DEGRADED
+ --#STATUS MANDATORY
+ ::= 8689
+
+ ------------------------------------------------------------------------------
+ -- Chassis Alerts 2: Audit: IO Virtualization Traps
+ --
+ -- Category: Audit/4
+ -- Subcategory: IOV/63
+ ------------------------------------------------------------------------------
+
+ alert2IOVirtualizationAuditWarning TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "IO Virtualization audit warning."
+ --#TYPE "Audit: IO Virtualization Warning"
+ --#SEVERITY MINOR
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Status Events"
+ --#STATE DEGRADED
+ --#STATUS MANDATORY
+ ::= 8698
+
+ ------------------------------------------------------------------------------
+ -- Chassis Alerts 2: Audit: License Traps
+ --
+ -- Category: Audit/4
+ -- Subcategory: LIC/40
+ ------------------------------------------------------------------------------
+
+ alert2LicenseInformation TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "License information."
+ --#TYPE "Audit: License Information"
+ --#SEVERITY INFORMATIONAL
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Status Events"
+ --#STATE OPERATIONAL
+ --#STATUS MANDATORY
+ ::= 8515
+
+ alert2LicenseWarning TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "License warning."
+ --#TYPE "Audit: License Warning"
+ --#SEVERITY MINOR
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Status Events"
+ --#STATE DEGRADED
+ --#STATUS MANDATORY
+ ::= 8514
+
+ alert2LicenseFailure TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "License failure."
+ --#TYPE "Audit: License Failure"
+ --#SEVERITY CRITICAL
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Error Events"
+ --#STATE DEGRADED
+ --#STATUS MANDATORY
+ ::= 8513
+
+ ------------------------------------------------------------------------------
+ -- Chassis Alerts 2: Audit: PCI Device Traps
+ --
+ -- Category: Audit/4
+ -- Subcategory: PCI/46
+ ------------------------------------------------------------------------------
+
+ alert2PCIDeviceAuditWarning TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "PCI device audit warning."
+ --#TYPE "Audit: PCI Device Warning"
+ --#SEVERITY MINOR
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Status Events"
+ --#STATE DEGRADED
+ --#STATUS MANDATORY
+ ::= 8562
+
+ ------------------------------------------------------------------------------
+ -- Chassis Alerts 2: Audit: Power Supply Traps
+ --
+ -- Category: Audit/4
+ -- Subcategory: PSU/17
+ ------------------------------------------------------------------------------
+
+ alert2PowerSupplyAuditWarning TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Power Supply audit warning."
+ --#TYPE "Audit: Power Supply Warning"
+ --#SEVERITY MINOR
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Status Events"
+ --#STATE DEGRADED
+ --#STATUS MANDATORY
+ ::= 8330
+
+ alert2PowerSupplyAuditFailure TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Power Supply audit failure or critical event."
+ --#TYPE "Audit: Power Supply Failure"
+ --#SEVERITY CRITICAL
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Error Events"
+ --#STATE DEGRADED
+ --#STATUS MANDATORY
+ ::= 8329
+
+ ------------------------------------------------------------------------------
+ -- Chassis Alerts 2: Audit: Power Usage Traps
+ --
+ -- Category: Audit/4
+ -- Subcategory: PWR/28
+ ------------------------------------------------------------------------------
+
+ alert2PowerUsageAuditInformation TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Power usage audit information."
+ --#TYPE "Audit: Power Usage Information"
+ --#SEVERITY INFORMATIONAL
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Status Events"
+ --#STATE OPERATIONAL
+ --#STATUS MANDATORY
+ ::= 8419
+
+ alert2PowerUsageAuditWarning TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Power usage audit warning."
+ --#TYPE "Audit: Power Usage Warning"
+ --#SEVERITY MINOR
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Status Events"
+ --#STATE DEGRADED
+ --#STATUS MANDATORY
+ ::= 8418
+
+ alert2PowerUsageAuditFailure TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Power usage audit failure or critical event."
+ --#TYPE "Audit: Power Usage Failure"
+ --#SEVERITY CRITICAL
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Error Events"
+ --#STATE DEGRADED
+ --#STATUS MANDATORY
+ ::= 8417
+
+ ------------------------------------------------------------------------------
+ -- Chassis Alerts 2: Audit: Software Change Traps
+ --
+ -- Category: Audit/4
+ -- Subcategory: SWU/21
+ ------------------------------------------------------------------------------
+
+ alert2SoftwareChangeAuditFailure TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Software change audit failure or critical event."
+ --#TYPE "Audit: Software Change Failure"
+ --#SEVERITY CRITICAL
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Error Events"
+ --#STATE DEGRADED
+ --#STATUS MANDATORY
+ ::= 8361
+
+ ------------------------------------------------------------------------------
+ -- Chassis Alerts 2: Configuration: IO Virtualization Traps
+ --
+ -- Category: Configuration/5
+ -- Subcategory: IOV/63
+ ------------------------------------------------------------------------------
+
+ alert2IOVConfigurationInformation TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "IO Virtualization configuration information."
+ --#TYPE "Configuration: IO Virtualization Information"
+ --#SEVERITY INFORMATIONAL
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Status Events"
+ --#STATE OPERATIONAL
+ --#STATUS MANDATORY
+ ::= 10747
+
+ alert2IOVConfigurationWarning TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "IO Virtualization configuration warning."
+ --#TYPE "Configuration: IO Virtualization Warning"
+ --#SEVERITY MINOR
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Status Events"
+ --#STATE DEGRADED
+ --#STATUS MANDATORY
+ ::= 10746
+
+ ------------------------------------------------------------------------------
+ -- Chassis Alerts 2: Configuration: PCI Device Traps
+ --
+ -- Category: Configuration/5
+ -- Subcategory: PCI/46
+ ------------------------------------------------------------------------------
+
+ alert2PCIDeviceConfigurationInformation TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "PCI device configuration information."
+ --#TYPE "Configuration: PCI Device Information"
+ --#SEVERITY INFORMATIONAL
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Status Events"
+ --#STATE OPERATIONAL
+ --#STATUS MANDATORY
+ ::= 10611
+
+ ------------------------------------------------------------------------------
+ -- Chassis Alerts 2: Configuration: Software Configuration Traps
+ --
+ -- Category: Configuration/5
+ -- Subcategory: SWC/36
+ ------------------------------------------------------------------------------
+
+ alert2SWCConfigurationWarning TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Software configuration warning."
+ --#TYPE "Configuration: Software Configuration Warning"
+ --#SEVERITY MINOR
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Status Events"
+ --#STATE DEGRADED
+ --#STATUS MANDATORY
+ ::= 10530
+
+ alert2SWCConfigurationFailure TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Software configuration failure."
+ --#TYPE "Configuration: Software Configuration Failure"
+ --#SEVERITY CRITICAL
+ --#SUMMARY "Message ID: %s, Message: %s,"
+ --#SUMMARY "Device Status: %d, Device FQDD: %s,"
+ --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
+ --#SUMMARY "Chassis Location: %s, Global Status: %d"
+ --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
+ --#CATEGORY "Error Events"
+ --#STATE DEGRADED
+ --#STATUS MANDATORY
+ ::= 10529
+
+ ------------------------------------------------------------------------------
+ -- Chassis Alerts 2: Configuration: Test Traps
+ --
+ -- Category: Configuration/5
+ -- Subcategory: TST/19
+ ------------------------------------------------------------------------------
+
+ alert2CMCTestTrap TRAP-TYPE
+ ENTERPRISE drsCMCAlert2Group
+ VARIABLES { drsCA2MessageID,
+ drsCA2Message,
+ drsCA2MessageArgs,
+ drsCA2AlertStatus,
+ drsCA2FQDD,
+ drsProductChassisName,
+ drsProductChassisLocation,
+ drsChassisServiceTag,
+ drsGlobalCurrStatus }
+ DESCRIPTION
+ "Test trap generated by CMC in response to a user request."
+ --#TYPE "Configuration: CMC Test Trap"
+ --#SEVERITY INFORMATIONAL
+ --#SUMMARY "%s"
+ --#ARGUMENTS {1}
+ --#CATEGORY "Status Events"
+ --#STATE OPERATIONAL
+ --#STATUS MANDATORY
+ ::= 10395
+
+ -------------------------------------------------------------------------------
+ -- group: Legacy Alerts
+ -------------------------------------------------------------------------------
+
+ drsAlertSystem OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (0..255))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "5000.0010.0001 Name of the system generating the alert."
+ --DEFAULT get-function-async get_%n_async
+ --DEFAULT next-function-async std_next_async
+ ::= { drsAlertVariables 1 }
+
+ drsAlertTableIndexOID OBJECT-TYPE
+ SYNTAX OBJECT IDENTIFIER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "5000.0010.0002 0.0"
+ --DEFAULT get-function-async get_OID_null_async
+ --DEFAULT next-function-async std_next_async
+ ::= { drsAlertVariables 2 }
+
+ drsAlertMessage OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (0..1024))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "5000.0010.0003 Message describing the alert."
+ --DEFAULT get-function-async get_string_null_async
+ --DEFAULT next-function-async std_next_async
+ ::= { drsAlertVariables 3 }
+
+ drsAlertCurrentStatus OBJECT-TYPE
+ SYNTAX DellStatus
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "5000.0010.0004 Current status of object causing the alert."
+ --DEFAULT get-function-async get_dellstatus_unknow_async
+ --DEFAULT next-function-async std_next_async
+ ::= { drsAlertVariables 4 }
+
+ drsAlertPreviousStatus OBJECT-TYPE
+ SYNTAX DellStatus
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "5000.0010.0005 Previous status of object causing the alert."
+ --DEFAULT get-function-async get_dellstatus_unknow_async
+ --DEFAULT next-function-async std_next_async
+ ::= { drsAlertVariables 5 }
+
+ drsAlertData OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (0..1024))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "5000.0010.0006 Alert data."
+ --DEFAULT get-function-async get_string_null_async
+ --DEFAULT next-function-async std_next_async
+ ::= { drsAlertVariables 6 }
+
+ alertDrscTestTrapEvent TRAP-TYPE
+ ENTERPRISE drsOutofBandGroup
+ VARIABLES { drsAlertSystem,
+ drsAlertTableIndexOID,
+ drsAlertMessage,
+ drsAlertCurrentStatus,
+ drsAlertPreviousStatus,
+ drsAlertData }
+ DESCRIPTION
+ "The RAC generated a test trap event in response to a user request."
+ --#TYPE "Dell RAC Test TRAP Event"
+ --#SUMMARY "%s"
+ --#ARGUMENTS {2}
+ --#SEVERITY INFORMATIONAL
+ --#CATEGORY Status Events
+ ::= 1001
+
+ alertDrscAuthError TRAP-TYPE
+ ENTERPRISE drsOutofBandGroup
+ VARIABLES { drsAlertSystem,
+ drsAlertTableIndexOID,
+ drsAlertMessage,
+ drsAlertCurrentStatus,
+ drsAlertPreviousStatus,
+ drsAlertData }
+ DESCRIPTION
+ "The RAC Authentication Failures during a time period have Exceeded a Threshold."
+ --#TYPE "Dell RAC Authentication Error"
+ --#SUMMARY "%s"
+ --#ARGUMENTS {2}
+ --#SEVERITY MINOR
+ --#CATEGORY Error Events
+ ::= 1002
+
+ alertDrscLostESM TRAP-TYPE
+ ENTERPRISE drsOutofBandGroup
+ VARIABLES { drsAlertSystem,
+ drsAlertTableIndexOID,
+ drsAlertMessage,
+ drsAlertCurrentStatus,
+ drsAlertPreviousStatus,
+ drsAlertData }
+ DESCRIPTION
+ "The RAC cannot communicate with the baseboard management controller (ESM)."
+ --#TYPE "Dell RAC Lost Communication with ESM"
+ --#SUMMARY "%s"
+ --#ARGUMENTS {2}
+ --#SEVERITY MINOR
+ --#CATEGORY Error Events
+ ::= 1003
+
+ alertDrscFoundESM TRAP-TYPE
+ ENTERPRISE drsOutofBandGroup
+ VARIABLES { drsAlertSystem,
+ drsAlertTableIndexOID,
+ drsAlertMessage,
+ drsAlertCurrentStatus,
+ drsAlertPreviousStatus,
+ drsAlertData }
+ DESCRIPTION
+ "The RAC is communicating normally with the baseboard management controller (ESM)."
+ --#TYPE "Dell RAC Communication with ESM is OK"
+ --#SUMMARY "%s"
+ --#ARGUMENTS {2}
+ --#SEVERITY INFORMATIONAL
+ --#CATEGORY Error Events
+ ::= 1004
+
+ alertDrscPowerOff TRAP-TYPE
+ ENTERPRISE drsOutofBandGroup
+ VARIABLES { drsAlertSystem,
+ drsAlertTableIndexOID,
+ drsAlertMessage,
+ drsAlertCurrentStatus,
+ drsAlertPreviousStatus,
+ drsAlertData }
+ DESCRIPTION
+ "The RAC has detected a System power state change to powered-off."
+ --#TYPE "Dell RAC Detected System Powered-Off"
+ --#SUMMARY "%s"
+ --#ARGUMENTS {2}
+ --#SEVERITY CRITICAL
+ --#CATEGORY Error Events
+ ::= 1005
+
+ alertDrscPowerOn TRAP-TYPE
+ ENTERPRISE drsOutofBandGroup
+ VARIABLES { drsAlertSystem,
+ drsAlertTableIndexOID,
+ drsAlertMessage,
+ drsAlertCurrentStatus,
+ drsAlertPreviousStatus,
+ drsAlertData }
+ DESCRIPTION
+ "The RAC has detected a system power state change to powered-on."
+ --#TYPE "Dell RAC Detected System Powered-On"
+ --#SUMMARY "%s"
+ --#ARGUMENTS {2}
+ --#SEVERITY INFORMATIONAL
+ --#CATEGORY Error Events
+ ::= 1006
+
+ alertDrscWatchdogExpired TRAP-TYPE
+ ENTERPRISE drsOutofBandGroup
+ VARIABLES { drsAlertSystem,
+ drsAlertTableIndexOID,
+ drsAlertMessage,
+ drsAlertCurrentStatus,
+ drsAlertPreviousStatus,
+ drsAlertData }
+ DESCRIPTION
+ "The RAC has detected that the system watchdog has expired indicating a system hang."
+ --#TYPE "Dell RAC Detected Watchdog Expired"
+ --#SUMMARY "%s"
+ --#ARGUMENTS {2}
+ --#SEVERITY CRITICAL
+ --#CATEGORY Error Events
+ ::= 1007
+
+ alertDrscBattLow TRAP-TYPE
+ ENTERPRISE drsOutofBandGroup
+ VARIABLES { drsAlertSystem,
+ drsAlertTableIndexOID,
+ drsAlertMessage,
+ drsAlertCurrentStatus,
+ drsAlertPreviousStatus,
+ drsAlertData }
+ DESCRIPTION
+ "The RAC Battery charge is below 25% indicating that the battery may only be able to power the DRSC for 8-10 minutes."
+ --#TYPE "Dell RAC Battery Charge Low"
+ --#SUMMARY "%s"
+ --#ARGUMENTS {2}
+ --#SEVERITY MINOR
+ --#CATEGORY Error Events
+ ::= 1008
+
+ alertDrscTempNormal TRAP-TYPE
+ ENTERPRISE drsOutofBandGroup
+ VARIABLES { drsAlertSystem,
+ drsAlertTableIndexOID,
+ drsAlertMessage,
+ drsAlertCurrentStatus,
+ drsAlertPreviousStatus,
+ drsAlertData }
+ DESCRIPTION
+ "The RAC Temperature probe has retured to a normal value."
+ --#TYPE "Dell RAC Temperature Normal"
+ --#SUMMARY "%s"
+ --#ARGUMENTS {2}
+ --#SEVERITY INFORMATIONAL
+ --#CATEGORY Error Events
+ ::= 1009
+
+ alertDrscTempWarning TRAP-TYPE
+ ENTERPRISE drsOutofBandGroup
+ VARIABLES { drsAlertSystem,
+ drsAlertTableIndexOID,
+ drsAlertMessage,
+ drsAlertCurrentStatus,
+ drsAlertPreviousStatus,
+ drsAlertData }
+ DESCRIPTION
+ "The RAC Temperature probe has detected a Warning value."
+ --#TYPE "Dell RAC Temperature Warning"
+ --#SUMMARY "%s"
+ --#ARGUMENTS {2}
+ --#SEVERITY MINOR
+ --#CATEGORY Error Events
+ ::= 1010
+
+ alertDrscTempCritical TRAP-TYPE
+ ENTERPRISE drsOutofBandGroup
+ VARIABLES { drsAlertSystem,
+ drsAlertTableIndexOID,
+ drsAlertMessage,
+ drsAlertCurrentStatus,
+ drsAlertPreviousStatus,
+ drsAlertData }
+ DESCRIPTION
+ "The RAC Temperature probe has detected a failure (or critical) value."
+ --#TYPE "Dell RAC Temperature Failure"
+ --#SUMMARY "%s"
+ --#ARGUMENTS {2}
+ --#SEVERITY CRITICAL
+ --#CATEGORY Error Events
+ ::= 1011
+
+ alertDrscVoltNormal TRAP-TYPE
+ ENTERPRISE drsOutofBandGroup
+ VARIABLES { drsAlertSystem,
+ drsAlertTableIndexOID,
+ drsAlertMessage,
+ drsAlertCurrentStatus,
+ drsAlertPreviousStatus,
+ drsAlertData }
+ DESCRIPTION
+ "The RAC voltage has returned to a normal value."
+ --#TYPE "Dell RAC Voltage Normal"
+ --#SUMMARY "%s"
+ --#ARGUMENTS {2}
+ --#SEVERITY INFORMATIONAL
+ --#CATEGORY Error Events
+ ::= 1012
+
+ alertDrscVoltWarning TRAP-TYPE
+ ENTERPRISE drsOutofBandGroup
+ VARIABLES { drsAlertSystem,
+ drsAlertTableIndexOID,
+ drsAlertMessage,
+ drsAlertCurrentStatus,
+ drsAlertPreviousStatus,
+ drsAlertData }
+ DESCRIPTION
+ "The RAC voltage probe has detected a warning value."
+ --#TYPE "Dell RAC Battery Warning"
+ --#SUMMARY "%s"
+ --#ARGUMENTS {2}
+ --#SEVERITY MINOR
+ --#CATEGORY Error Events
+ ::= 1013
+
+ alertDrscVoltCritical TRAP-TYPE
+ ENTERPRISE drsOutofBandGroup
+ VARIABLES { drsAlertSystem,
+ drsAlertTableIndexOID,
+ drsAlertMessage,
+ drsAlertCurrentStatus,
+ drsAlertPreviousStatus,
+ drsAlertData }
+ DESCRIPTION
+ "The RAC voltage probe has detected a failure (or critical) value."
+ --#TYPE "Dell RAC Voltage Failure"
+ --#SUMMARY "%s"
+ --#ARGUMENTS {2}
+ --#SEVERITY CRITICAL
+ --#CATEGORY Error Events
+ ::= 1014
+
+ alertDrscSELWarning TRAP-TYPE
+ ENTERPRISE drsOutofBandGroup
+ VARIABLES { drsAlertSystem,
+ drsAlertTableIndexOID,
+ drsAlertMessage,
+ drsAlertCurrentStatus,
+ drsAlertPreviousStatus,
+ drsAlertData }
+ DESCRIPTION
+ "The RAC has detected a new event in the System Event Log with Severity: Warning."
+ --#TYPE "Dell RAC System Event Log Warning"
+ --#SUMMARY "%s"
+ --#ARGUMENTS {2}
+ --#SEVERITY MAJOR
+ --#CATEGORY Error Events
+ ::= 1015
+
+ alertDrscSELCritical TRAP-TYPE
+ ENTERPRISE drsOutofBandGroup
+ VARIABLES { drsAlertSystem,
+ drsAlertTableIndexOID,
+ drsAlertMessage,
+ drsAlertCurrentStatus,
+ drsAlertPreviousStatus,
+ drsAlertData }
+ DESCRIPTION
+ "The RAC has detected a new event in the System Event Log with Severity: Critical."
+ --#TYPE "Dell RAC System Event Log Critical"
+ --#SUMMARY "%s"
+ --#ARGUMENTS {2}
+ --#SEVERITY CRITICAL
+ --#CATEGORY Error Events
+ ::= 1016
+
+ alertDrscSEL80percentFull TRAP-TYPE
+ ENTERPRISE drsOutofBandGroup
+ VARIABLES { drsAlertSystem,
+ drsAlertTableIndexOID,
+ drsAlertMessage,
+ drsAlertCurrentStatus,
+ drsAlertPreviousStatus,
+ drsAlertData }
+ DESCRIPTION
+ "The RAC has detected that the System Event Log is 80% full."
+ --#TYPE "Dell System Event Log 80% Full Warning"
+ --#SUMMARY "%s"
+ --#ARGUMENTS {2}
+ --#SEVERITY MAJOR
+ --#CATEGORY Status Events
+ ::= 1017
+
+ alertDrscSEL90percentFull TRAP-TYPE
+ ENTERPRISE drsOutofBandGroup
+ VARIABLES { drsAlertSystem,
+ drsAlertTableIndexOID,
+ drsAlertMessage,
+ drsAlertCurrentStatus,
+ drsAlertPreviousStatus,
+ drsAlertData }
+ DESCRIPTION
+ "The RAC has detected that the System Event Log is 90% full."
+ --#TYPE " Dell System Event Log 90% Full Warning "
+ --#SUMMARY "%s"
+ --#ARGUMENTS {2}
+ --#SEVERITY MAJOR
+ --#CATEGORY Status Events
+ ::= 1018
+
+ alertDrscSEL100percentFull TRAP-TYPE
+ ENTERPRISE drsOutofBandGroup
+ VARIABLES { drsAlertSystem,
+ drsAlertTableIndexOID,
+ drsAlertMessage,
+ drsAlertCurrentStatus,
+ drsAlertPreviousStatus,
+ drsAlertData }
+ DESCRIPTION
+ "The RAC has detected that the System Event Log is 100% full."
+ --#TYPE " Dell System Event Log 100% Full Warning "
+ --#SUMMARY "%s"
+ --#ARGUMENTS {2}
+ --#SEVERITY MAJOR
+ --#CATEGORY Status Events
+ ::= 1019
+
+ alertDrscSELNormal TRAP-TYPE
+ ENTERPRISE drsOutofBandGroup
+ VARIABLES { drsAlertSystem,
+ drsAlertTableIndexOID,
+ drsAlertMessage,
+ drsAlertCurrentStatus,
+ drsAlertPreviousStatus,
+ drsAlertData }
+ DESCRIPTION
+ "The RAC has detected a new event in the System Event Log with Severity: Normal."
+ --#TYPE "Dell RAC System Event Log Normal"
+ --#SUMMARY "%s"
+ --#ARGUMENTS {2}
+ --#SEVERITY INFORMATIONAL
+ --#CATEGORY Error Events
+ ::= 1020
+END
+