diff options
| author | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
|---|---|---|
| committer | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
| commit | 98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch) | |
| tree | 9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/dell/FASTPATH-BOXSERVICES-PRIVATE-MIB | |
| download | mibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.tar.gz mibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.zip | |
Diffstat (limited to 'MIBS/dell/FASTPATH-BOXSERVICES-PRIVATE-MIB')
| -rw-r--r-- | MIBS/dell/FASTPATH-BOXSERVICES-PRIVATE-MIB | 430 |
1 files changed, 430 insertions, 0 deletions
diff --git a/MIBS/dell/FASTPATH-BOXSERVICES-PRIVATE-MIB b/MIBS/dell/FASTPATH-BOXSERVICES-PRIVATE-MIB new file mode 100644 index 0000000..9e580eb --- /dev/null +++ b/MIBS/dell/FASTPATH-BOXSERVICES-PRIVATE-MIB @@ -0,0 +1,430 @@ +-- Box Services MIB overview: +-- Box Services MIB falls under fastPath MIB node of the private subtree. + +FASTPATH-BOXSERVICES-PRIVATE-MIB DEFINITIONS ::= BEGIN + +-- Broadcom Corporation FASTPATH Box Services MIB +-- Copyright Broadcom Corporation(2004-2008) All rights reserved. + +-- This SNMP Management Information Specification +-- embodies Broadcom Corporation's confidential and proprietary +-- intellectual property. Broadcom Corporation retains all title +-- and ownership in the Specification including any revisions. + +-- This Specification is supplied "AS IS", Broadcom Corporation +-- makes no warranty, either expressed or implied, +-- as to the use, operation, condition, or performance of the +-- Specification. + + +IMPORTS + MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, + Unsigned32, Integer32 FROM SNMPv2-SMI + TEXTUAL-CONVENTION FROM SNMPv2-TC + DisplayString FROM RFC1213-MIB + fastPath FROM BROADCOM-REF-MIB; + + fastPathBoxServices MODULE-IDENTITY + LAST-UPDATED "200802220000Z" -- 22 Feb 2008 12:00:00 GMT + ORGANIZATION "Broadcom Corporation" + CONTACT-INFO + " Customer Support + Postal: Broadcom Corporation + 100 Perimeter Park Dr., Suite H + Morrisville, NC 27560 + Tel: +1 919 865 2700" + + DESCRIPTION + "The Broadcom Private MIB for FASTPATH Box Services Feature." + + -- Revision history. + REVISION + "200802220000Z" -- 22 Feb 2008 12:00:00 GMT + DESCRIPTION + "Broadcom branding related changes." + + ::= { fastPath 43 } + +--************************************************************************************** +-- boxServicesGroup +-- +-- This group provides configuration and status of the Box Services +-- feature. +-- +--************************************************************************************** + + boxServicesGroup OBJECT IDENTIFIER ::= { fastPathBoxServices 1 } + + --************************************************************************************** + -- Some scalars + + boxServicesNormalTempRangeMin OBJECT-TYPE + SYNTAX INTEGER (-100..100) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " Lower boundary of normal temperature range." + DEFVAL { 0 } + ::= { boxServicesGroup 1 } + + boxServicesNormalTempRangeMax OBJECT-TYPE + SYNTAX INTEGER (-100..100) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " Upper boundary of normal temperature range." + DEFVAL { 45 } + ::= { boxServicesGroup 2 } + + boxServicesTemperatureTrapEnable OBJECT-TYPE + SYNTAX INTEGER { + enable(1), + disable(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " Enable or disable temperature change event trap, raised when temperature crosses boundaries of normal range" + DEFVAL { enable } + ::= { boxServicesGroup 3 } + + boxServicesPSMStateTrapEnable OBJECT-TYPE + SYNTAX INTEGER { + enable(1), + disable(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " Enable or disable Power Supply Module state change trap." + DEFVAL { enable } + ::= { boxServicesGroup 4 } + + boxServicesFanStateTrapEnable OBJECT-TYPE + SYNTAX INTEGER { + enable(1), + disable(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " Enable or disable Fan state change trap." + DEFVAL { enable } + ::= { boxServicesGroup 5 } + + --************************************************************************************** + -- boxServicesFans + + boxServicesFansTable OBJECT-TYPE + SYNTAX SEQUENCE OF BoxServicesFansEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Fan" + ::= { boxServicesGroup 6 } + + boxServicesFansEntry OBJECT-TYPE + SYNTAX BoxServicesFansEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Box Services Fan Entry" + INDEX { boxServicesFansIndex } + ::= { boxServicesFansTable 1 } + + BoxServicesFansEntry ::= SEQUENCE { + boxServicesFansIndex + Integer32, + boxServicesFanItemType + INTEGER, + boxServicesFanItemState + INTEGER, + boxServicesFanSpeed + Integer32, + boxServicesFanDutyLevel + Integer32 + } + + boxServicesFansIndex OBJECT-TYPE + SYNTAX Integer32 (0..2147483647) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Unique index of fan table entry" + ::= { boxServicesFansEntry 1 } + + boxServicesFanItemType OBJECT-TYPE + SYNTAX INTEGER { + fixed(1), + removable(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The type of fan" + ::= { boxServicesFansEntry 2 } + + + boxServicesFanItemState OBJECT-TYPE + SYNTAX INTEGER { + notpresent(1), + operational(2), + failed(3) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The status of fan" + ::= { boxServicesFansEntry 3 } + + + boxServicesFanSpeed OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The speed of fan" + ::= { boxServicesFansEntry 4} + + boxServicesFanDutyLevel OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The duty level of fan, in percents" + ::= { boxServicesFansEntry 5} + + + --************************************************************************************** + -- boxServicesPowSupplies + + boxServicesPowSuppliesTable OBJECT-TYPE + SYNTAX SEQUENCE OF BoxServicesPowSuppliesEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Power supply" + ::= { boxServicesGroup 7 } + + boxServicesPowSuppliesEntry OBJECT-TYPE + SYNTAX BoxServicesPowSuppliesEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Box Services Power Supply Entry" + INDEX { boxServicesPowSupplyIndex } + ::= { boxServicesPowSuppliesTable 1 } + + BoxServicesPowSuppliesEntry ::= SEQUENCE { + boxServicesPowSupplyIndex + Integer32, + boxServicesPowSupplyItemType + INTEGER, + boxServicesPowSupplyItemState + INTEGER + } + + boxServicesPowSupplyIndex OBJECT-TYPE + SYNTAX Integer32 (0..2147483647) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Unique index of power supply table entry" + ::= { boxServicesPowSuppliesEntry 1 } + + boxServicesPowSupplyItemType OBJECT-TYPE + SYNTAX INTEGER { + fixed(1), + removable(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The type of power supply" + ::= { boxServicesPowSuppliesEntry 2 } + + + boxServicesPowSupplyItemState OBJECT-TYPE + SYNTAX INTEGER { + notpresent(1), + operational(2), + failed(3) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The status of power supply" + ::= { boxServicesPowSuppliesEntry 3 } + + + --************************************************************************************** + -- boxServicesTempSensors + + + boxServicesTempSensorsTable OBJECT-TYPE + SYNTAX SEQUENCE OF BoxServicesTempSensorsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Temperature sensor" + ::= { boxServicesGroup 8 } + + + boxServicesTempSensorsEntry OBJECT-TYPE + SYNTAX BoxServicesTempSensorsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Box Services Temperature Sensor Entry" + INDEX { boxServicesTempSensorIndex } + ::= { boxServicesTempSensorsTable 1 } + + BoxServicesTempSensorsEntry ::= SEQUENCE { + boxServicesTempSensorIndex + Integer32, + boxServicesTempSensorType + INTEGER, + boxServicesTempSensorState + INTEGER, + boxServicesTempSensorTemperature + Integer32 + } + + boxServicesTempSensorIndex OBJECT-TYPE + SYNTAX Integer32 (0..2147483647) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Unique index of temperature sensor table entry" + ::= { boxServicesTempSensorsEntry 1 } + + + boxServicesTempSensorType OBJECT-TYPE + SYNTAX INTEGER { + fixed(1), + removable(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The type of temperature sensor" + ::= { boxServicesTempSensorsEntry 2 } + + + boxServicesTempSensorState OBJECT-TYPE + SYNTAX INTEGER { + normal(1), + warning(2), + critical(3), + shutdown(4), + notpresent(5), + notoperational(6) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The state of temperature sensor" + ::= { boxServicesTempSensorsEntry 3 } + + + boxServicesTempSensorTemperature OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The temperature value reported by sensor" + ::= { boxServicesTempSensorsEntry 4} + + +--************************************************************************************** +-- boxServicesNotificationsGroup +-- +-- This group provides notification definitions for the Box Services +-- feature. +-- +--************************************************************************************** + + boxServicesNotificationsGroup OBJECT IDENTIFIER ::= { fastPathBoxServices 2 } + + --************************************************************************************** + -- boxServices notification definitions + + boxsItemStateChangeEvent OBJECT-TYPE + SYNTAX INTEGER { + insertion(1), + removal(2), + becomeoperational(3), + failure(4) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This event describes states of the fan or power supply. + + insertion - hot-pluggable fan or power supply was inserted + removal - hot-pluggable fan or power supply was removed + becomeoperational - fan or power supply became operational after failure state + failure - fan or power supply failure happened, i.e. it is not able to perform its functions" + ::= { boxServicesNotificationsGroup 1 } + + boxsTemperatureChangeEvent OBJECT-TYPE + SYNTAX INTEGER { + abovethreshold(1), + belowthreshold(2), + withinnormalrange(3) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This event describes change of the temperature. + To avoid flipping on boundary conditions, it is allowed to send the trap + taking into account some margin around thresholds. + + abovethreshold - temperature increased and crossed upper threshold value + belowthreshold - temperature decreased and crossed lower threshold value + withinnormalrange - temperature returned to normal range (between threshold)" + ::= { boxServicesNotificationsGroup 2 } + + + + +--************************************************************************************** +-- Traps +--************************************************************************************** + + fastPathBoxServicesTraps OBJECT IDENTIFIER ::= { fastPathBoxServices 0 } + + + + boxsFanStateChange NOTIFICATION-TYPE + OBJECTS { + boxServicesFansIndex, + boxsItemStateChangeEvent + } + STATUS current + DESCRIPTION + "Trap is sent when fan state change happens." + ::= { fastPathBoxServicesTraps 1 } + + boxsPowSupplyStateChange NOTIFICATION-TYPE + OBJECTS { + boxServicesPowSupplyIndex, + boxsItemStateChangeEvent + } + STATUS current + DESCRIPTION + "Trap is sent when power supply state change happens." + ::= { fastPathBoxServicesTraps 2 } + + + boxsTemperatureChange NOTIFICATION-TYPE + OBJECTS { + boxServicesTempSensorIndex, + boxsTemperatureChangeEvent + } + STATUS current + DESCRIPTION + "Trap is sent when temperature is changing and crossing any of the thresholds" + ::= { fastPathBoxServicesTraps 3 } + +END |