diff options
| author | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
|---|---|---|
| committer | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
| commit | 98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch) | |
| tree | 9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/eaton/EATON-OIDS | |
| download | mibs-main.tar.gz mibs-main.zip | |
Diffstat (limited to 'MIBS/eaton/EATON-OIDS')
| -rw-r--r-- | MIBS/eaton/EATON-OIDS | 193 |
1 files changed, 193 insertions, 0 deletions
diff --git a/MIBS/eaton/EATON-OIDS b/MIBS/eaton/EATON-OIDS new file mode 100644 index 0000000..fd27c46 --- /dev/null +++ b/MIBS/eaton/EATON-OIDS @@ -0,0 +1,193 @@ +EATON-OIDS DEFINITIONS ::= BEGIN + +IMPORTS + MODULE-IDENTITY, enterprises FROM SNMPv2-SMI + Integer32 FROM SNMPv2-SMI + TEXTUAL-CONVENTION FROM SNMPv2-TC; + +eaton MODULE-IDENTITY + LAST-UPDATED "201811130000Z" + ORGANIZATION "Eaton Corporation" + CONTACT-INFO + "Eaton Power Quality Technical Support (PQTS) group + www.eaton.com/powerxpert + Technical Resource Center phone numbers + United States: 1.800.843.9433 or 919.870.3028 + Canada: 1.800.461.9166 ext. 260 + All other countries: Call your local service representative." + DESCRIPTION + "Assigns major branches from the root of + Eaton's OID tree (534). + + Copyright (C) Exide Electronics 1992-98 + Copyright (C) Powerware Corporation 1999-2004 + Copyright (C) Eaton Corporation (2005-)." + + REVISION "201811130000Z" + DESCRIPTION + "Added assignments for eatonSensor MIB." + + REVISION "201402190000Z" + DESCRIPTION + "Added assignments for stsMIB." + + REVISION "201001240000Z" + DESCRIPTION + "Added assignments for eatonEpdu and eatonEpduMa." + + REVISION "200906180000Z" + DESCRIPTION + "Added assignments for powerCmnd and OSDCIIMIB." + + + REVISION "200708060000Z" + DESCRIPTION + "Added assignments for pcdMIB and pxmMIB. + Added common Textual Conventions for Integers." + + REVISION "200707050000Z" + DESCRIPTION + "Added assignment for eatonEpduMIB. + Cleaned up file for public consumption." + + REVISION "200610150000Z" + DESCRIPTION + "Added assignments for powerChain and pxgMIB." + + REVISION "200605250000Z" + DESCRIPTION + "Revised from the original assignments in XUPS-MIB.txt. + Note that enterprises.534. was originally assigned to Exide + Electronics before Powerware was acquired by Eaton." + + ::= { enterprises 534 } + +-- EATON-OIDS { iso org(3) dod(6) internet(1) private(4) +-- enterprises(1) eaton(534) } + + +-- The Powerware "PowerMIB" for UPSs +xupsMIB OBJECT IDENTIFIER ::= {eaton 1} +-- Define the Environment group here since it is used in the Eaton-EMP-MIB as well +xupsEnvironment OBJECT IDENTIFIER ::= {xupsMIB 6} + +-- +-- The root of the list of Object Identifiers that are used to +-- distinguish Eaton's SNMP agents (for use in sysObjId): +xupsObjectId OBJECT IDENTIFIER ::= {eaton 2} + powerwareEthernetSnmpAdapter OBJECT IDENTIFIER ::= {xupsObjectId 1} + powerwareNetworkSnmpAdapterEther OBJECT IDENTIFIER ::= {xupsObjectId 2} + powerwareNetworkSnmpAdapterToken OBJECT IDENTIFIER ::= {xupsObjectId 3} + onlinetDaemon OBJECT IDENTIFIER ::= {xupsObjectId 4} + connectUPSAdapterEthernet OBJECT IDENTIFIER ::= {xupsObjectId 5} + powerwareNetworkDigitalIOEther OBJECT IDENTIFIER ::= {xupsObjectId 6} + connectUPSAdapterTokenRing OBJECT IDENTIFIER ::= {xupsObjectId 7} + simpleSnmpAdapter OBJECT IDENTIFIER ::= {xupsObjectId 8} + powerwareEliSnmpAdapter OBJECT IDENTIFIER ::= {xupsObjectId 9} + powerwareBasicEmbeddedEthernet OBJECT IDENTIFIER ::= {xupsObjectId 10} + eatonPowerChainGateway OBJECT IDENTIFIER ::= {xupsObjectId 11} + eatonPowerChainDevice OBJECT IDENTIFIER ::= {xupsObjectId 12} + eatonPowerXpertMeter OBJECT IDENTIFIER ::= {xupsObjectId 13} + + +-- Digital IO MIB (deprecated) +-- File XUPSIOV1.MIB +xupsIoMIB OBJECT IDENTIFIER ::= {eaton 3} + +-- DataTrax Forseer and Powervision branch +powerVision OBJECT IDENTIFIER ::= {eaton 4} + +-- orphaned: BEEP (Basic Embedded Ethernet Product) +-- File XUPS-BASIC-MIB.txt +--xupsBasic OBJECT IDENTIFIER ::= {eaton 5} + +-- A branch for Powerware Product MIBs +products OBJECT IDENTIFIER ::= {eaton 6} + -- Product assignments + + pduAgent OBJECT IDENTIFIER ::= {products 6} + -- pduAgent product assignments + -- File MIB_hdpdu.mib for HD PDU + hdpdu OBJECT IDENTIFIER ::= {pduAgent 2} + + -- MIB for Eaton PDU, first for 9315's 3-phase PDU + -- Defined in EATON-PDU-MIB.txt + eatonPdu OBJECT IDENTIFIER ::= {pduAgent 4} + + -- MIB for Eaton Powerware first-generation Managed ePDUs + -- Defined in EATON-EPDU-MA-MIB.txt + -- eatonEpduMa OBJECT IDENTIFIER ::= {pduAgent 6} + + -- MIB for Eaton Powerware ePDUs + -- Defined in EATON-EPDU-MIB.txt + -- eatonEpdu OBJECT IDENTIFIER ::= {pduAgent 7} + + sensorAgent OBJECT IDENTIFIER ::= {products 8} + -- sensorAgent product assignments + -- MIB for Eaton Sensors + -- Defined in EATON-SENSOR-MIB.txt + -- eatonSensor OBJECT IDENTIFIER ::= {sensorAgent 1} + + + dataCenter OBJECT IDENTIFIER ::= {products 7} + -- dataCenter product assignments + environmentalMonitor OBJECT IDENTIFIER ::= {dataCenter 1} + + +-- A branch for Eaton IT Department +itProjects OBJECT IDENTIFIER ::= {eaton 7} + pki OBJECT IDENTIFIER ::= {itProjects 1} + +-- A branch for PowerChain Product MIBs +powerChain OBJECT IDENTIFIER ::= {eaton 8} + -- Product assignments + + -- MIB to support Alarms and Events in PowerXpert toolkit-enabled + -- Devices, Gateways, PXMeters + -- Defined in file EATON-PXG-MIB.txt + -- pxgMIB OBJECT IDENTIFIER ::= {powerChain 1} + + -- MIB to support common measures in Power Chain Devices + -- Defined in file EATON-PCD-MIB.txt + -- pcdMIB OBJECT IDENTIFIER ::= {powerChain 2} + + -- MIB to support power measures in Power Meters + -- Defined in file EATON-PWR-MTR-MIB.txt + -- pxmMIB OBJECT IDENTIFIER ::= {powerChain 3} + +-- A branch for powercomand commercial control Product MIBs +powerCmnd OBJECT IDENTIFIER ::= {eaton 9} + + -- Product assignments + -- MIB to support the OSDCII controller + -- Defined in file EATON-OSDCII-MIB.txt + -- osdcMIB OBJECT IDENTIFIER ::= {powerCmnd 1} + +-- A branch for Eaton STS devices MIBs +sts OBJECT IDENTIFIER ::= {eaton 10} + + -- Product assignments + -- MIB to support the data in STS devices + -- Defined in file Eaton-STS.MIB + -- stsMIB OBJECT IDENTIFIER ::= {ats 1} + +-- Define some common Textual Conventions +-- PositiveInteger and NonNegativeInteger are borrowed from RFC1628 + PositiveInteger ::= TEXTUAL-CONVENTION + DISPLAY-HINT "d" + STATUS current + DESCRIPTION + "This data type is a non-zero and non-negative value." + SYNTAX Integer32 (1..2147483647) + + NonNegativeInteger ::= TEXTUAL-CONVENTION + DISPLAY-HINT "d" + STATUS current + DESCRIPTION + "This data type is a non-negative value." + SYNTAX Integer32 (0..2147483647) + + + + END + |