diff options
| author | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
|---|---|---|
| committer | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
| commit | 98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch) | |
| tree | 9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/emerson/EES-POWER-MIB | |
| download | mibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.tar.gz mibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.zip | |
Diffstat (limited to 'MIBS/emerson/EES-POWER-MIB')
| -rw-r--r-- | MIBS/emerson/EES-POWER-MIB | 1115 |
1 files changed, 1115 insertions, 0 deletions
diff --git a/MIBS/emerson/EES-POWER-MIB b/MIBS/emerson/EES-POWER-MIB new file mode 100644 index 0000000..b8bb824 --- /dev/null +++ b/MIBS/emerson/EES-POWER-MIB @@ -0,0 +1,1115 @@ +------------------------------------------------------------ +-- Emerson Energy Systems (EES) +-- Power MIB +------------------------------------------------------------ + +EES-POWER-MIB DEFINITIONS ::= BEGIN + + +IMPORTS + MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, + Integer32, Counter32, enterprises + FROM SNMPv2-SMI + TEXTUAL-CONVENTION, DisplayString, DateAndTime + FROM SNMPv2-TC; + + +powerMIB MODULE-IDENTITY + LAST-UPDATED "201504100857Z" + ORGANIZATION " + Emerson Energy Systems (EES)" + CONTACT-INFO " + Emerson Energy Systems + 141 82 Stockholm + Sweden" + DESCRIPTION " + Emerson Energy Systems (EES) Power MIB, revision D." + ::= { enterprises 6302 2 1 } + +------------------------------------------------------------ +-- Node definitions +------------------------------------------------------------ + +ees OBJECT IDENTIFIER ::= { enterprises 6302 } + +global OBJECT IDENTIFIER ::= { ees 2 } + +------------------------------------------------------------ +-- Textual conventions +------------------------------------------------------------ + +Status ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION " + This integer value represents the operational or administrative + status of the system. Also used as alarm severity. + Depending on situation there may be limits on allowed values. + Operational values: + (1) unknown - status has not yet been defined + (2) normal - there are no activated alarms + (3) warning - OA, lowest level of 'abnormal' status + (4) minor - A3 + (5) major - MA + (6) critical - CA, highest level of 'abnormal' status + Administrative values: + (7) unmanaged + (8) restricted + (9) testing + (10) disabled" + SYNTAX INTEGER { + unknown(1), + normal(2), + warning(3), + minor(4), + major(5), + critical(6), + unmanaged(7), + restricted(8), + testing(9), + disabled(10) } + +StatusChange ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION " + Indicates 'activated' (1) or 'deactivated' (2) alarm events." + SYNTAX INTEGER { + activated(1), + deactivated(2) } + + +------------------------------------------------------------ +-- 1.1 Identification of the plant { powerMIB 1 } +------------------------------------------------------------ + +ident OBJECT IDENTIFIER ::= { powerMIB 1 } + +identManufacturer OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION " + The name of the equipment manufacturer." + ::= { ident 1 } + +identModel OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION " + The manufacturers model designation of the power system." + ::= { ident 2 } + +identControllerFirmwareVersion OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION " + The firmware (software) version of the controller." + ::= { ident 3 } + +identName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION " + The name of the power plant. This object should be set by + the administrator." + ::= { ident 4 } + +identSNMPCfgVer OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION " + The snmp cfg version" + ::= { ident 5 } + +identControllerSerialNumber OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION " + The serial number of this controller" + ::= { ident 6 } + +------------------------------------------------------------ +-- 1.2 System values { powerMIB 2 } +------------------------------------------------------------ + +system OBJECT IDENTIFIER ::= { powerMIB 2 } + +systemStatus OBJECT-TYPE + SYNTAX Status + MAX-ACCESS read-only + STATUS current + DESCRIPTION " + Status of the complete plant (highest alarm). One of + (1) unknown - status has not yet been defined + (2) normal - there are no activated alarms + (3) warning - OA, lowest level of 'abnormal' status + (4) minor - A3 + (5) major - MA + (6) critical - CA, highest level of 'abnormal' status + (7) unmanaged + (8) restricted + (9) testing + (10) disabled" + ::= { system 1 } + +systemVoltage OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION " + System voltage, stored as mV, including positive or negative + sign. The integer 2147483647 represents invalid value." + ::= { system 2 } + +systemCurrent OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION " + System current, stored as mA, including positive or negative + sign. The integer 2147483647 represents invalid value." + ::= { system 3 } + +systemUsedCapacity OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION " + Used capacity, stored as % of the total capacity. + The integer 2147483647 represents invalid value." + ::= { system 4 } + + + +-- ------------------------------------------------------------------------ +-- 1.2.5. Battery group +-- ------------------------------------------------------------------------ + +psBattery OBJECT IDENTIFIER ::= { system 5 } + + psBatteryVoltage OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Battery voltage, stored as mV, including positive or negative + sign. The integer 2147483647 represents invalid value." + ::= { psBattery 1 } + + psTotalBatteryCurrent OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Battery current, stored as mA, including positive or negative + sign. The integer 2147483647 represents invalid value." + ::= { psBattery 2 } + + psBatteryCapacity OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION " + Calculated capacity, stored as % of the total capacity. + The integer 2147483647 represents invalid value." + ::= { psBattery 3 } + + psBatteryNominalCapacity OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION " + nominal installed capacity, stored as mAh. + The integer 2147483647 represents invalid value." + ::= { psBattery 4 } + + psBatteryTable OBJECT-TYPE + SYNTAX SEQUENCE OF PSBatteryEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Battery Table." + ::= { psBattery 5 } + + psBatteryEntry OBJECT-TYPE + SYNTAX PSBatteryEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Battery Measurement Table Entry." + INDEX { psBatteryIndex } + ::= { psBatteryTable 1 } + + PSBatteryEntry ::= SEQUENCE { + psBatteryIndex Integer32, + psBatteryCurrent Integer32, + psBatteryName DisplayString + } + + psBatteryIndex OBJECT-TYPE + SYNTAX Integer32(1..16777215) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Automatically generated index object." + ::= { psBatteryEntry 1 } + + psBatteryCurrent OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Battery current in Amps." + ::= { psBatteryEntry 2 } + + psBatteryName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Battery shunt name." + ::= { psBatteryEntry 3 } + + +-- ------------------------------------------------------------------------ +-- 1.2.6. the psInput group +-- ------------------------------------------------------------------------ + +psInput OBJECT IDENTIFIER ::= { system 6 } + + psInputLineAVoltage OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The AC line A voltage, stored as mV. The integer 2147483647 + represents invalid value." + ::= { psInput 1 } + + psInputLineBVoltage OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The AC line B voltage, stored as mV. The integer 2147483647 + represents invalid value." + ::= { psInput 2 } + + psInputLineCVoltage OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The AC line C voltage, stored as mV. The integer 2147483647 + represents invalid value." + ::= { psInput 3 } + +-- ------------------------------------------------------------------------ +-- 1.2.7. the temperatures +-- ------------------------------------------------------------------------ + +psTemperature OBJECT IDENTIFIER ::= { system 7 } + + psTemperature1 OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The first route temperature, stored as 0.001 Celsius degree. + The integer 2147483647 represents invalid value." + ::= { psTemperature 1 } + + psTemperature2 OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The second route temperature, stored as 0.001 Celsius degree. + The integer 2147483647 represents invalid value.." + ::= { psTemperature 2 } + + + psTemperatureTable OBJECT-TYPE + SYNTAX SEQUENCE OF PSTemperatureEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Temperature Measurement Table." + ::= { psTemperature 3 } + + psTemperatureEntry OBJECT-TYPE + SYNTAX PSTemperatureEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Temperature Measurement Table Entry." + INDEX { psTemperatureIndex } + ::= { psTemperatureTable 1 } + + PSTemperatureEntry ::= SEQUENCE { + psTemperatureIndex Integer32, + psTemperatureMeasurement Integer32, + psTemperatureName DisplayString, + psTemperatureType INTEGER, + psTemperatureAlarmStatus INTEGER + } + + psTemperatureIndex OBJECT-TYPE + SYNTAX Integer32(1..71) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Temperature Probe Number " + ::= { psTemperatureEntry 1 } + + psTemperatureMeasurement OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Temperature Value In Centigrade." + ::= { psTemperatureEntry 2 } + + psTemperatureName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Configured Temperature Probe Name." + ::= { psTemperatureEntry 3 } + + psTemperatureType OBJECT-TYPE + SYNTAX INTEGER { + none(0), + ambient(1), + battery(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Temperature Probe Type " + ::= { psTemperatureEntry 4 } + + psTemperatureAlarmStatus OBJECT-TYPE + SYNTAX INTEGER { + high(0), + low(1), + fail(2), + none(3) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Temperature Probe Alarm Status " + ::= { psTemperatureEntry 5 } + +psStatusCommunication OBJECT-TYPE + SYNTAX INTEGER { + unknown(1), + normal(2), + interrupt(3) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The status of communication with the Power System. interrupt(3) indicates + some errors occurred between Power System and agent." + ::= { system 8 } + +psStatusBatteryMode OBJECT-TYPE + SYNTAX INTEGER { + unknown(1), + floatCharging(2), + shortTest(3), + bcForTest(4), + manualTesting(5), + planTesting(6), + acFailTesting(7), + acFail(8), + manualBC(9), + autoBC(10), + cyclicBC(11), + masterBC(12), + masterBT(13) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The status of battery modes, + FloatCharging(2), + ShortTest(3), + BoostChargingForTest(4), + ManualTesting(5), + PlanTesting(6), + ACFailTesting(7), + ACFail(8), + ManualBoostCharging(9), + AutoBoostCharging(10), + CyclicBoostCharging(11), + MasterBoostCharging(12), + MasterBateryTesting(13)." + ::= { system 9 } + +-- ------------------------------------------------------------------------ +-- 1.2.10. the SM series group(only get number of SM series) +-- ------------------------------------------------------------------------ + +psSMNumber OBJECT IDENTIFIER ::= { system 10 } + + psSMACNumber OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of SM AC module." + ::= { psSMNumber 1 } + + psSMBATNumber OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of SM BAT module." + ::= { psSMNumber 2 } + + psSMIONumber OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of SM IO module." + ::= { psSMNumber 3 } + +-- ------------------------------------------------------------------------ +-- 1.2.11. Rectifier group +-- ------------------------------------------------------------------------ + +psRectifier OBJECT IDENTIFIER ::= { system 11 } + +numberOfInstalledRectifiers OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION " + number of rectifiers, stored as integer. + The integer 2147483647 represents invalid value." + ::= { psRectifier 1 } + +numberOfRectifiersCommunicating OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION " + number of rectifiers communicating, stored as integer. + The integer 2147483647 represents invalid value." + ::= { psRectifier 2 } + +rectifiersUsedCapacity OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION " + Used capacity, stored as % of the total capacity. + The integer 2147483647 represents invalid value." + ::= { psRectifier 3 } + +psRectifierTable OBJECT-TYPE + SYNTAX SEQUENCE OF PSRectifierEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION " + Table holding information about indivual rectifiers." + ::= { psRectifier 4 } + +psRectifierEntry OBJECT-TYPE + SYNTAX PSRectifierEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION " + An entry (conceptual row) in the rectifierInfoTable." + INDEX { psRectifierIndex } + ::= { psRectifierTable 1 } + +PSRectifierEntry ::= SEQUENCE { + psRectifierIndex Integer32, + psRectifierProductNumber DisplayString, + psRectifierHWVersion DisplayString, + psRectifierSWVersion DisplayString, + psRectifierSerialNumber DisplayString, + psRectifierCurrent Integer32, + psRectifierIdent DisplayString, + psRectifierFail StatusChange + } + +psRectifierIndex OBJECT-TYPE + SYNTAX Integer32(1..16777215) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Automatically generated index object." +::= { psRectifierEntry 1 } + +psRectifierProductNumber OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Rectifier Product Number." +::= { psRectifierEntry 2} + +psRectifierHWVersion OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Rectifier Hardware Revision." +::= { psRectifierEntry 3} + +psRectifierSWVersion OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Rectifier Software Revision." +::= { psRectifierEntry 4} + +psRectifierSerialNumber OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Rectifier Serial Number." +::= { psRectifierEntry 5} + +psRectifierCurrent OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Rectifier Current." +::= { psRectifierEntry 6} + +psRectifierIdent OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Rectifier physical location identifier." +::= { psRectifierEntry 7} + +psRectifierFail OBJECT-TYPE + SYNTAX StatusChange + MAX-ACCESS read-only + STATUS current + DESCRIPTION " + The type of alarm change. One of + (1) activated + (2) deactivated" +::= { psRectifierEntry 8} + +-- ------------------------------------------------------------------------ +-- 1.2.12. the Distribution +-- ------------------------------------------------------------------------ + +psDistribution OBJECT IDENTIFIER ::= { system 12 } + +psTotalLoadCurrent OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION " + Total Load current, stored as integer. + The integer 2147483647 represents invalid value." + ::= { psDistribution 1 } + psDistributionLoadTable OBJECT-TYPE + SYNTAX SEQUENCE OF PSDistributionLoadEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Distribution Table." + ::= { psDistribution 2 } + + psDistributionLoadEntry OBJECT-TYPE + SYNTAX PSDistributionLoadEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Distribution Measurement Table Entry." + INDEX { psDistributionLoadIndex } + ::= { psDistributionLoadTable 1 } + + PSDistributionLoadEntry ::= SEQUENCE { + psDistributionLoadIndex Integer32, + psDistributionLoadCurrent Integer32, + psDistributionLoadName DisplayString + } + + psDistributionLoadIndex OBJECT-TYPE + SYNTAX Integer32(1..268386303) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Automatically generated index object." + ::= { psDistributionLoadEntry 1 } + + psDistributionLoadCurrent OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Distribution current in Amps." + ::= { psDistributionLoadEntry 2 } + + psDistributionLoadName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Distribution name." + ::= { psDistributionLoadEntry 3 } + + psDistributionGeneralTable OBJECT-TYPE + SYNTAX SEQUENCE OF PSDistributionGeneralEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Distribution Table." + ::= { psDistribution 3 } + + psDistributionGeneralEntry OBJECT-TYPE + SYNTAX PSDistributionGeneralEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Distribution Measurement Table Entry." + INDEX { psDistributionGeneralIndex } + ::= { psDistributionGeneralTable 1 } + + PSDistributionGeneralEntry ::= SEQUENCE { + psDistributionGeneralIndex Integer32, + psDistributionGeneralCurrent Integer32, + psDistributionGeneralName DisplayString + } + + psDistributionGeneralIndex OBJECT-TYPE + SYNTAX Integer32(1..268386303) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Automatically generated index object." + ::= { psDistributionGeneralEntry 1 } + + psDistributionGeneralCurrent OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Distribution current in Amps." + ::= { psDistributionGeneralEntry 2 } + + psDistributionGeneralName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Distribution name." + ::= { psDistributionGeneralEntry 3 } + +-- ------------------------------------------------------------------------ +-- 1.2.13. Converter group +-- ------------------------------------------------------------------------ + +psConverter OBJECT IDENTIFIER ::= { system 13 } + +numberOfInstalledConverters OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION " + number of converters, stored as integer. + The integer 2147483647 represents invalid value." + ::= { psConverter 1 } + +numberOfConvertersCommunicating OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION " + number of converters communicating, stored as integer. + The integer 2147483647 represents invalid value." + ::= { psConverter 2 } + +convertersUsedCapacity OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION " + Used capacity, stored as % of the total capacity. + The integer 2147483647 represents invalid value." + ::= { psConverter 3 } + +psConverterVoltage OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION " + Converter voltage in mV. + The integer 2147483647 represents invalid value." + ::= { psConverter 4 } + +psTotalConverterCurrent OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION " + Total Converter current in Amps. + The integer 2147483647 represents invalid value." + ::= { psConverter 5 } + +psConverterTable OBJECT-TYPE + SYNTAX SEQUENCE OF PSConverterEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION " + Table holding information about indivual converters." + ::= { psConverter 6 } + +psConverterEntry OBJECT-TYPE + SYNTAX PSConverterEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION " + An entry (conceptual row) in the ConverterInfoTable." + INDEX { psConverterIndex } + ::= { psConverterTable 1 } + +PSConverterEntry ::= SEQUENCE { + psConverterIndex Integer32, + psConverterProductNumber DisplayString, + psConverterHWVersion DisplayString, + psConverterSWVersion DisplayString, + psConverterSerialNumber DisplayString, + psConverterCurrent Integer32, + psConverterIdent DisplayString, + psConverterFail StatusChange } + +psConverterIndex OBJECT-TYPE + SYNTAX Integer32(1..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Automatically generated index object." +::= { psConverterEntry 1 } + +psConverterProductNumber OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Converter Product Number." +::= { psConverterEntry 2} + +psConverterHWVersion OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Converter Hardware Revision." +::= { psConverterEntry 3} + +psConverterSWVersion OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Converter Software Revision." +::= { psConverterEntry 4} + +psConverterSerialNumber OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Converter Serial Number." +::= { psConverterEntry 5} + +psConverterCurrent OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Converter Current." +::= { psConverterEntry 6} + +psConverterIdent OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Converter physical location identifier." +::= { psConverterEntry 7} + +psConverterFail OBJECT-TYPE + SYNTAX StatusChange + MAX-ACCESS read-only + STATUS current + DESCRIPTION " + The type of alarm change. One of + (1) activated + (2) deactivated" +::= { psConverterEntry 8} + +-- ------------------------------------------------------------------------ +-- 1.2.14. Control group +-- ------------------------------------------------------------------------ + +psControl OBJECT IDENTIFIER ::= { system 14 } + +controlBatteryTest OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION " + Control battery test, start(1), stop (0)." + ::= { psControl 1 } + +controlRelay8 OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION " + Control relay8, close(1), open(0)." + ::= { psControl 2 } + +controlRelay7 OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION " + Control relay7, close(1), open(0)." + ::= { psControl 3 } + +controlRelay6 OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION " + Control relay6, close(1), open(0)." + ::= { psControl 4 } + +controlRelayTest OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION " + Control Relay test, start(1), stop (0)." + ::= { psControl 5 } + + +-- ------------------------------------------------------------------------ +-- 1.2.15. EquipmentSignalTable +-- ------------------------------------------------------------------------ + +psEquipmentSignalTable OBJECT-TYPE + SYNTAX SEQUENCE OF EquipmentSignalTableEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION " + Table of indexed equipment signal values." + ::= { system 15 } + +equipmentSignalTableEntry OBJECT-TYPE + SYNTAX EquipmentSignalTableEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION " + An entry (conceptual row) in the psEquipment Signal Table." + INDEX { psEquipmentSignalTableEntryIndex } + ::= { psEquipmentSignalTable 1 } + +EquipmentSignalTableEntry ::= SEQUENCE { + psEquipmentSignalTableEntryIndex Integer32, + psEquipmentSignalValue Integer32 } + +psEquipmentSignalTableEntryIndex OBJECT-TYPE + SYNTAX Integer32(1..268386303) + MAX-ACCESS read-only + STATUS current + DESCRIPTION " + The unique sequence number of this equipment signal." + ::= { equipmentSignalTableEntry 1 } + +psEquipmentSignalValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION " + Indexed equipment signal value." + ::= { equipmentSignalTableEntry 2 } + +------------------------------------------------------------ +-- Alarm trap counter { powerMIB 3 } +------------------------------------------------------------ + +alarmLastTrapNo OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION " + The sequence number of last submitted alarm trap, + also last row in alarmTrapTable." + ::= { powerMIB 3 } + +------------------------------------------------------------ +-- Active Alarm table { powerMIB 4 } +------------------------------------------------------------ + +alarmActiveAlarmTable OBJECT-TYPE + SYNTAX SEQUENCE OF ActiveAlarmEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION " + Table holding information about the currently active alarms." + ::= { powerMIB 4 } + +activeAlarmEntry OBJECT-TYPE + SYNTAX ActiveAlarmEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION " + An entry (conceptual row) in the alarmTrapTable." + INDEX { alarmIndex } + ::= { alarmActiveAlarmTable 1 } + +ActiveAlarmEntry ::= SEQUENCE { + alarmIndex Counter32, + alarmTime DateAndTime, + alarmStatusChange StatusChange, + alarmSeverity Status, + alarmDescription DisplayString, + alarmType Integer32 } + +alarmIndex OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION " + The unique sequence number of this alarm trap." + ::= { activeAlarmEntry 1 } + +alarmTime OBJECT-TYPE + SYNTAX DateAndTime + MAX-ACCESS read-only + STATUS current + DESCRIPTION " + Date and time when event occured (local time), including + timezone if supported by controller." + ::= { activeAlarmEntry 2 } + +alarmStatusChange OBJECT-TYPE + SYNTAX StatusChange + MAX-ACCESS read-only + STATUS current + DESCRIPTION " + The type of alarm change. One of + (1) activated + (2) deactivated" + ::= { activeAlarmEntry 3 } + +alarmSeverity OBJECT-TYPE + SYNTAX Status + MAX-ACCESS read-only + STATUS current + DESCRIPTION " + The severity of the alarm. One of + (3) warning - OA, lowest level of alarm severity + (4) minor - A3 + (5) major - MA + (6) critical - CA, highest level of alarm severity" + ::= { activeAlarmEntry 4 } + +alarmDescription OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION " + Free-text description of alarm." + ::= { activeAlarmEntry 5 } + +alarmType OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION " + Alarm type, i.e. an integer specifying the type of alarm." + ::= { activeAlarmEntry 6 } + +------------------------------------------------------------ +-- Events/traps { powerMIB 5 } +------------------------------------------------------------ + +powerEvents OBJECT IDENTIFIER ::= { powerMIB 5 } + +alarmTrap NOTIFICATION-TYPE + OBJECTS { + alarmIndex, + alarmTime, + alarmStatusChange, + alarmSeverity, + alarmDescription, + alarmType } + STATUS current + DESCRIPTION " + An alarm trap is sent when an alarm occurs (activated) or + returns to normal state (deactivated). Alarm traps are logged + in alarmTrapTable. Variables in this trap: + * alarmIndex - The unique sequence number of this alarm trap. + * alarmTime - Date and time when event occured (local time), + including timezone if supported by controller. + * alarmStatusChange - (1) activated or (2) deactivated. + * alarmSeverity - Integer describing the severity of the alarm. + * alarmDescription - Free-text description of alarm. + * alarmType - Integer indicating type of alarm." + ::= { powerEvents 1 } + +alarmActiveTrap NOTIFICATION-TYPE + OBJECTS { + alarmTime, + alarmSeverity, + alarmDescription, + alarmType } + STATUS current + DESCRIPTION " + An alarm trap is sent when an alarm occurs (activated) + Variables in this trap + * alarmTime - Date and time when event occured (local time), + including timezone if supported by controller. + * alarmSeverity - Integer describing the severity of the alarm. + * alarmDescription - Free-text description of alarm. + * alarmType - Integer indicating type of alarm." + ::= { powerEvents 2 } + +alarmCeaseTrap NOTIFICATION-TYPE + OBJECTS { + alarmTime, + alarmSeverity, + alarmDescription, + alarmType } + STATUS current + DESCRIPTION " + An alarm trap is sent when an alarm returns to normal state (clear, deactivated). + Variables in this trap: + * alarmTime - Date and time when event occured (local time), + including timezone if supported by controller. + * alarmSeverity - Integer describing the severity of the alarm. + * alarmDescription - Free-text description of alarm. + * alarmType - Integer indicating type of alarm." + ::= { powerEvents 3 } + +------------------------------------------------------------ +-- End of MIB definitions +------------------------------------------------------------ + +END |