diff options
| author | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
|---|---|---|
| committer | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
| commit | 98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch) | |
| tree | 9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/enterasys/CTRON-POWER-SUPPLY-MIB | |
| download | mibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.tar.gz mibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.zip | |
Diffstat (limited to 'MIBS/enterasys/CTRON-POWER-SUPPLY-MIB')
| -rw-r--r-- | MIBS/enterasys/CTRON-POWER-SUPPLY-MIB | 913 |
1 files changed, 913 insertions, 0 deletions
diff --git a/MIBS/enterasys/CTRON-POWER-SUPPLY-MIB b/MIBS/enterasys/CTRON-POWER-SUPPLY-MIB new file mode 100644 index 0000000..7ccde3e --- /dev/null +++ b/MIBS/enterasys/CTRON-POWER-SUPPLY-MIB @@ -0,0 +1,913 @@ +CTRON-POWER-SUPPLY-MIB DEFINITIONS ::= BEGIN + + -- ctron-power-supply-mib.txt The power supply MIB + -- Revision: 1.01.02 + -- Part Number: + -- Date: March 26, 1997 + + -- Cabletron Systems, Inc. + -- 35 Industrial Way, P.O. Box 5005 + -- Rochester, NH 03867-0505 + -- (603) 332-9400 + -- support@ctron.com + + -- This module provides authoritative definitions for Cabletron's + -- enterprise-specific chassis MIB. + -- + -- This module will be extended, as needed. + -- + + -- Cabletron Systems reserves the right to make changes in + -- specification and other information contained in this document + -- without prior notice. The reader should consult Cabletron Systems + -- to determine whether any such changes have been made. + -- + -- In no event shall Cabletron Systems be liable for any incidental, + -- indirect, special, or consequential damages whatsoever (including + -- but not limited to lost profits) arising out of or related to this + -- document or the information contained in it, even if Cabletron + -- Systems has been advised of, known, or should have known, the + -- possibility of such damages. + -- + -- Cabletron grants vendors, end-users, and other interested parties + -- a non-exclusive license to use this Specification in connection + -- with the management of Cabletron products. + + -- Copyright August 95 Cabletron Systems + + + -- This MIB describes objects for MMAC+ style power supplies. + + IMPORTS + ctps + FROM CTRON-MIB-NAMES + OBJECT-TYPE + FROM RFC-1212; + + + + --=============== group definitions =================== + + chPower OBJECT IDENTIFIER ::= { ctps 1 } + boardPower OBJECT IDENTIFIER ::= { ctps 2 } + psPower OBJECT IDENTIFIER ::= { ctps 3 } + bbuPower OBJECT IDENTIFIER ::= { ctps 4 } + termPower OBJECT IDENTIFIER ::= { ctps 5 } + + --=============== chPower group ==================== + + -- Chassis Power Group + -- Implementation of the Chassis Power group is optional. + -- It needs to be supported when an EM is present and operational + -- in the chassis. + -- This group covers information on the chassis power available. + + chPowerOperationalStatus OBJECT-TYPE + SYNTAX INTEGER { + powerAC(1), + powerACRedundant(2), + powerDC(3), + powerDCRedundant(4), + battery(5) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This object reflects the overall status of the chassis's + power supply in terms of how the power is being delivered + to the chassis." + ::= { chPower 1 } + + chPowerMainVoltageStatus OBJECT-TYPE + SYNTAX INTEGER { + powerOK(1), + overCurrent(2), + overVoltage(3), + underVoltage(4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This object reflects the state of the main voltage + rail within the chassis. The power on this rail may + be delivered by AC supplies, DC supplies or battery + supplies." + ::= { chPower 2 } + + chPowerMainVoltage OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The voltage of the chassis's main voltage rail. This rail + carries power to all the modules in the chassis. It has + an allowable range of 40 volts to 60 volts DC. The value + of this object is the actual voltage * 10." + ::= { chPower 3 } + + chPowerTotalSupply OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The total power being supplied by the chassis's power + supplies to the chassis. The value of this object is the + actual watts." + ::= { chPower 4 } + + chPowerTotalLoad OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The total load being presented by the chassis to the + chassis's power supplies. The value of + this object is the actual watts." + ::= { chPower 5 } + + chPowerMaxSupply OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The maximum power that could de supplied by the chassis's power + supplies to the chassis. The value of this object is the + actual watts." + ::= { chPower 6 } + + chPowerMaxLoad OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The maximum load that could be presented by the chassis to the + chassis's power supplies. The value of + this object is the actual watts." + ::= { chPower 7 } + + chPowerTable OBJECT-TYPE + SYNTAX SEQUENCE OF ChPowerEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of power lines or busses on the chassis's backplane." + ::= { chPower 8 } + + chPowerEntry OBJECT-TYPE + SYNTAX ChPowerEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A slot entry containing objects for a particular + module and associated power line." + INDEX { chPowerLineID } + ::= { chPowerTable 1 } + + ChPowerEntry ::= + SEQUENCE { + chPowerLineID + INTEGER, + chPowerLineType + OBJECT IDENTIFIER, + chPowerLineTotalSupply + INTEGER, + chPowerLineTotalLoad + INTEGER, + chPowerLineMaxSupply + INTEGER, + chPowerLineMaxLoad + INTEGER + } + + chPowerLineID OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A unique value used to identify a particular power line on + the chassis's backplane." + ::= { chPowerEntry 1 } + + chPowerLineType OBJECT-TYPE + SYNTAX OBJECT IDENTIFIER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The type of power. For example, a power line that supplies + DC current at a nominal voltage of 40 to 57 volts or a + power line that supplies AC current at a nominal volatge of + 110v." + ::= { chPowerEntry 2 } + + chPowerLineTotalSupply OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The total power being supplied by the chassis's power + supplies to the chassis on this power line. The value + of this object is the actual watts." + ::= { chPowerEntry 3 } + + chPowerLineTotalLoad OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The total load being presented by the chassis to the + chassis's power supplies on this power line. This value + will be zero if unknown The value of this object is the + actual watts." + ::= { chPowerEntry 4 } + + chPowerLineMaxSupply OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The maximum power that could de supplied by the chassis's power + supplies to the chassison this power line. The value of + this object is the actual watts." + ::= { chPowerEntry 5 } + + chPowerLineMaxLoad OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The maximum load that could be presented by the chassis to the + chassis's power supplies on this power line. The value of + this object is the actual watts." + ::= { chPowerEntry 6 } + + chPowerDiagVoltageStatus OBJECT-TYPE + SYNTAX INTEGER { + powerOK(1), + overCurrent(2), + overVoltage(3), + underVoltage(4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This object reflects the state of the diag voltage + rail within the chassis." + ::= { chPower 9 } + + chPowerDiagVoltage OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The voltage of the chassis's diag voltage rail. This rail + carries power to all the modules in the chassis. It has + an allowable range of 4.75 volts to 5.25 volts DC. The value + of this object is the actual voltage * 10." + ::= { chPower 10 } + + --=============== boardPower group ==================== + + -- Board Power Group + -- This group covers information on the use of power within the + -- chassis by the networking boards. + + boardPowerSlotStatusTable OBJECT-TYPE + SYNTAX SEQUENCE OF BoardPowerSlotStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of networking modules installed in this chassis." + ::= { boardPower 1 } + + boardPowerSlotStatusEntry OBJECT-TYPE + SYNTAX BoardPowerSlotStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A slot entry containing objects for a particular + module." + INDEX { boardPowerSlotStatusID } + ::= { boardPowerSlotStatusTable 1 } + + BoardPowerSlotStatusEntry ::= + SEQUENCE { + boardPowerSlotStatusID + INTEGER, + boardPowerOperationalStatus + INTEGER, + boardPowerAdminStatus + INTEGER, + boardPowerLocalAdminStatus + INTEGER, + boardPowerLocalStatus + INTEGER, + boardPowerShutdownAdmin + INTEGER, + boardPowerPriority + INTEGER, + boardPowerMaxInputPower + INTEGER, + boardPowerManagement + INTEGER + } + + boardPowerSlotStatusID OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The slot number of a chassis slot in which this board is + installed. This object is similiar to chSlotID in the + Chassis MIB." + ::= { boardPowerSlotStatusEntry 1 } + + boardPowerOperationalStatus OBJECT-TYPE + SYNTAX INTEGER { + powerOn(1), + powerOff(2), + reset(3), + overVoltage(4), + underVoltage(5), + overCurrent(6), + overCurrentShutdown(7), + temperatureShutdown(8), + remotePowerOff(9), + powerConservationShutdown(10), + frontPanelPowerOff(11) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This object reflects the status of the module's + DC-DC converter power supply." + ::= { boardPowerSlotStatusEntry 2 } + + boardPowerAdminStatus OBJECT-TYPE + SYNTAX INTEGER { + powerOn(1), + powerOff(2), + reset(3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "This object controls the operation of the module's + DC-DC power supply. If the value 3 is written to + this object then the value of the object will be + set to 1 after the reset is performed." + DEFVAL { powerOn } + ::= { boardPowerSlotStatusEntry 3 } + + boardPowerLocalAdminStatus OBJECT-TYPE + SYNTAX INTEGER { + localMode(1), + secureMode(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "This object controls the operation of the module's + front panel button. In local mode this button may + be used to locally control the operation of the + DC-DC converter, i.e. power on, power off and + reset. In secure mode a request the state of the + front panel button is reflected in the object + boardPowerOperationalStatus. In secure mode + the front panel button has no effect locally." + DEFVAL { localMode } + ::= { boardPowerSlotStatusEntry 4 } + + boardPowerLocalStatus OBJECT-TYPE + SYNTAX INTEGER { + resetRequest(1), + powerDownRequest(2), + powerOnRequest(3), + normal(4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This object reflects the state of the module's front + panel button." + ::= { boardPowerSlotStatusEntry 5 } + + boardPowerShutdownAdmin OBJECT-TYPE + SYNTAX INTEGER { + enabled(1), + disabled(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "This object controls whether or not the module should + auto power down due to an fault condition." + DEFVAL { disabled } + ::= { boardPowerSlotStatusEntry 6 } + + boardPowerPriority OBJECT-TYPE + SYNTAX INTEGER (1..14) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The module's power-up and power down priority. This is a + value of 1 to 14 and is used to decide which modules are + allowed to power on in the event that power demand of the + chassis is greater than the total power supply. The default + value is 14, highest priority. When two modules have equal + priority then the module in the lowest slot wins." + DEFVAL { 14 } + ::= { boardPowerSlotStatusEntry 7 } + + boardPowerMaxInputPower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The maximum input power that this module is allowed + to consume. The value of this object is actual + watts." + ::= { boardPowerSlotStatusEntry 8 } + + boardPowerManagement OBJECT-TYPE + SYNTAX INTEGER { + disabled(1), + enabled(2), + not-supported(7) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Module power management status." + DEFVAL { not-supported } + ::= { boardPowerSlotStatusEntry 9 } + + boardPowerSlotTable OBJECT-TYPE + SYNTAX SEQUENCE OF BoardPowerSlotEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of networking modules and associated power lines + installed in this chassis." + ::= { boardPower 2 } + + boardPowerSlotEntry OBJECT-TYPE + SYNTAX BoardPowerSlotEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A slot entry containing objects for a particular + module and associated power line." + INDEX { boardPowerSlotID, boardPowerID } + ::= { boardPowerSlotTable 1 } + + BoardPowerSlotEntry ::= + SEQUENCE { + boardPowerSlotID + INTEGER, + boardPowerID + INTEGER, + boardPowerType + OBJECT IDENTIFIER, + boardPowerStatus + INTEGER, + boardPowerVoltage + INTEGER, + boardPowerCurrent + INTEGER, + boardPowerMaxVoltage + INTEGER, + boardPowerMinVoltage + INTEGER, + boardPowerMaxPower + INTEGER + } + + boardPowerSlotID OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The slot number of a chassis slot in which this board is + installed. This object is similiar to chSlotID in the + Chassis MIB." + ::= { boardPowerSlotEntry 1 } + + boardPowerID OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A unique value used to identify a particular power line." + ::= { boardPowerSlotEntry 2 } + + boardPowerType OBJECT-TYPE + SYNTAX OBJECT IDENTIFIER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The type of power. For example, a power line that supplies + DC current at a nominal voltage of 40 to 57 volts or a + power line that supplies AC current at a nominal volatge of + 110v." + ::= { boardPowerSlotEntry 3 } + + boardPowerStatus OBJECT-TYPE + SYNTAX INTEGER { + powerOK(1), + powerOff(2), + overCurrent(3), + overVoltage(4), + underVoltage(5) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This object reflects the status of this power line." + ::= { boardPowerSlotEntry 4 } + + boardPowerVoltage OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The voltage reading for the power line. The value of this + object is actual voltage * 100." + ::= { boardPowerSlotEntry 5 } + + boardPowerCurrent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The current reading for the power line. The value of this + object is the actual amperage * 100. If this reading is not + implemented then value will be zero." + ::= { boardPowerSlotEntry 6 } + + boardPowerMaxVoltage OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The maximum voltage for this power line. If the voltage + reading for this power line is greater than this value + then the power line is considered to be in an overvolatge + condition. The value of this object is in voltage * 100." + ::= { boardPowerSlotEntry 7 } + + boardPowerMinVoltage OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The minimum voltage for this power line. If the voltage + reading for this power line is less than this value + then the power line is considered to be in an undervolatge + condition. The value of this object is voltage * 100." + ::= { boardPowerSlotEntry 8 } + + boardPowerMaxPower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The maximum power for this power line. If the power calculated + for this power line is greater than this value then the + power line is considered to be in an overload condition. + The value of this object is in watts." + ::= { boardPowerSlotEntry 9 } + + --=============== psPower group ==================== + + -- AC and DC Power Supply Power Group + -- This group covers information on the use of power within the + -- chassis by the networking boards. + + psPowerSlotStatusTable OBJECT-TYPE + SYNTAX SEQUENCE OF PsPowerSlotStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of AC & DC power supplies installed in this chassis." + ::= { psPower 1 } + + psPowerSlotStatusEntry OBJECT-TYPE + SYNTAX PsPowerSlotStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A slot entry containing objects for a particular + power supply." + INDEX { psPowerSlotStatusID } + ::= { psPowerSlotStatusTable 1 } + + PsPowerSlotStatusEntry ::= + SEQUENCE { + psPowerSlotStatusID + INTEGER, + psPowerOperationalStatus + INTEGER, + psPowerAdminStatus + INTEGER, + psPowerMaxOutputPower + INTEGER + } + + psPowerSlotStatusID OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The slot number of a chassis slot in which this AC power + supply is installed. This object is similiar + to chSlotID in the Chassis MIB." + ::= { psPowerSlotStatusEntry 1 } + + psPowerOperationalStatus OBJECT-TYPE + SYNTAX INTEGER { + powerOn(1), + powerOff(2), + reset(3), + overVoltage(4), + underVoltage(5), + overCurrent(6), + overCurrentShutdown(7), + temperatureShutdown(8), + remotePowerOff(9) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This object reflects the status of the module's + DC-DC converter power supply." + ::= { psPowerSlotStatusEntry 2 } + + psPowerAdminStatus OBJECT-TYPE + SYNTAX INTEGER { + powerOn(1), + powerOff(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "This object controls the operation of power supply." + DEFVAL { powerOn } + ::= { psPowerSlotStatusEntry 3 } + + psPowerMaxOutputPower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The maximum power that this power supply is allowed + to ouput. The value of this object is watts." + ::= { psPowerSlotStatusEntry 4 } + + psPowerSlotTable OBJECT-TYPE + SYNTAX SEQUENCE OF PsPowerSlotEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of power supplies and associated power lines + installed in this chassis." + ::= { psPower 2 } + + psPowerSlotEntry OBJECT-TYPE + SYNTAX PsPowerSlotEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A slot entry containing objects for a particular + power line on a particular power supply." + INDEX { psPowerSlotID, psPowerID } + ::= { psPowerSlotTable 1 } + + PsPowerSlotEntry ::= + SEQUENCE { + psPowerSlotID + INTEGER, + psPowerID + INTEGER, + psPowerType + OBJECT IDENTIFIER, + psPowerStatus + INTEGER, + psPowerAdmin + INTEGER, + psPowerVoltage + INTEGER, + psPowerCurrent + INTEGER, + psPowerLineFrequency + INTEGER, + psPowerMaxVoltage + INTEGER, + psPowerMinVoltage + INTEGER, + psPowerMaxPower + INTEGER + } + + psPowerSlotID OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The slot number of a chassis slot in which this Power + supply is installed. This object is similiar to + chSlotID in the Chassis MIB." + ::= { psPowerSlotEntry 1 } + + psPowerID OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A unique value used to identify a particular power line." + ::= { psPowerSlotEntry 2 } + + psPowerType OBJECT-TYPE + SYNTAX OBJECT IDENTIFIER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The type of power. For example, a power line that supplies + DC current at a nominal voltage of 40 to 57 volts or a + power line that supplies AC current at a nominal volatge of + 110v." + ::= { psPowerSlotEntry 3 } + + psPowerStatus OBJECT-TYPE + SYNTAX INTEGER { + powerOK(1), + powerOff(2), + overCurrent(3), + overVoltage(4), + underVoltage(5) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This object reflects the status of the power line." + ::= { psPowerSlotEntry 4 } + + psPowerAdmin OBJECT-TYPE + SYNTAX INTEGER { + powerOn(1), + powerOff(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "This object controls the operation of power supply." + DEFVAL { powerOn } + ::= { psPowerSlotEntry 5 } + + psPowerVoltage OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The voltage reading for the power line. The value of this + object is the actual voltage * 100." + ::= { psPowerSlotEntry 6 } + + psPowerCurrent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The current reading for the power line. The value of this + object is amperage * 100. If this reading is not implemented + then value will be zero." + ::= { psPowerSlotEntry 7 } + + psPowerLineFrequency OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The line frequency for the power line. The value of this + object is the actual frequency in Hertz * 10. If this + reading is not implemented then value will be zero." + ::= { psPowerSlotEntry 8 } + + psPowerMaxVoltage OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The maximum voltage for this power line. If the voltage + reading for this power line is greater than this value + then the power line is considered to be in an over volatge + condition. The value of this object is voltage * 100." + ::= { psPowerSlotEntry 9 } + + psPowerMinVoltage OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The minimum voltage for this power line. If the voltage + reading for this power line is greater than this value + then the power line is considered to be in an over volatge + condition. The value of this object is voltage * 100." + ::= { psPowerSlotEntry 10 } + + psPowerMaxPower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The maximum power for this power line. If the power calculated + for this power line is greater than this value then the + power line is considered to be in an overload condition. + The value of this object is watts." + ::= { psPowerSlotEntry 11 } + + --=============== bbuPower group ==================== + + -- Battery Backup Unit Power Group + -- This group covers information on the use of power within the + -- chassis by the battery backup unit. + + --=============== termPower group ==================== + + -- INB Termination Module Power Group + -- This group covers information on the use of power within the + -- chassis by the INB termination modules. + + termPowerStatus OBJECT-TYPE + SYNTAX INTEGER { + powerOK(1), + overCurrent(2), + overVoltage(3), + underVolatge(4), + overPower(5) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This object reflects the status of the chassis's termination + voltage rail." + ::= { termPower 1 } + + termPowerVoltage OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The voltage of the chassis's termination voltage rail. + This rail carries power to INB terminator cards in the + chassis. It has an allowalble range of 3.3 Volt + or - + 5%.The value of this object is voltage * 100." + ::= { termPower 2 } + + termPowerCurrent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The current on the chassis's termination voltage rail. + The value of this object is the actual amperage * 100. + If this reading is not implemented then the value will + be zero." + ::= { termPower 3 } + + termPowerModule1Status OBJECT-TYPE + SYNTAX INTEGER { + normal(1), + iNBaFault(2), + iNBbFault(3), + fault(4), + termModuleNotInstalled(5), + unknown(6) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This object reflects the state of the INB termination + module number 1. A value of normal(1) reflects that + both busses are normal. A value of fault(4) reflects + that both busses are in a fault condition." + ::= { termPower 4 } + + termPowerModule2Status OBJECT-TYPE + SYNTAX INTEGER { + normal(1), + iNBaFault(2), + iNBbFault(3), + fault(4), + termModuleNotInstalled(5), + unknown(6) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This object reflects the state of the INB termination + module number 2. A value of normal(1) reflects that + both busses are normal. A value of fault(4) reflects + that both busses are in a fault condition." + ::= { termPower 5 } + +END |