Diffstat (limited to 'MIBS/enterasys/CTRON-SFCS-MIB')
-rw-r--r--MIBS/enterasys/CTRON-SFCS-MIB5553
1 files changed, 5553 insertions, 0 deletions
diff --git a/MIBS/enterasys/CTRON-SFCS-MIB b/MIBS/enterasys/CTRON-SFCS-MIB
new file mode 100644
index 0000000..e04e4c5
--- /dev/null
+++ b/MIBS/enterasys/CTRON-SFCS-MIB
@@ -0,0 +1,5553 @@
+CTRON-SFCS-MIB DEFINITIONS ::= BEGIN
+
+-- ctron-sfcs-mib.txt
+-- Revision: 1.00.01
+-- Date: March 23, 1999
+
+
+-- Cabletron Systems, Inc.
+-- 35 Industrial Way, P.O. Box 5005
+-- Rochester, NH 03867-0505
+-- (603) 332-9400
+-- support@ctron.com
+
+-- This module provides authoritative definitions for Cabletron's
+-- enterprise specific Secure Fast Cell Switching MIB.
+--
+-- This module will be extended, as required.
+--
+
+-- Cabletron Systems reserves the right to make changes in
+-- specification and other information contained in this document
+-- without prior notice. The reader should consult Cabletron Systems
+-- to determine whether any such changes have been made.
+--
+-- In no event shall Cabletron Systems be liable for any incidental,
+-- indirect, special, or consequential damages whatsoever (including
+-- but not limited to lost profits) arising out of or related to this
+-- document or the information contained in it, even if Cabletron
+-- Systems has been advised of, known, or should have known, the
+-- possibility of such damages.
+--
+-- Cabletron grants vendors, end-users, and other interested parties
+-- a non-exclusive license to use this Specification in connection
+-- with the management of Cabletron products.
+-- Copyright October 98 Cabletron Systems
+--
+
+
+ IMPORTS
+ OBJECT-TYPE
+ FROM RFC-1212
+ DisplayString
+ FROM RFC1213-MIB
+ enterprises, IpAddress, TimeTicks
+ FROM RFC1155-SMI
+ TruthValue
+ FROM SNMPv2-TC
+ atmVcCrossConnectIndex, atmVcCrossConnectLowIfIndex,
+ atmVcCrossConnectLowVpi, atmVcCrossConnectLowVci,
+ atmVcCrossConnectHighIfIndex, atmVcCrossConnectHighVpi,
+ atmVcCrossConnectHighVci
+ FROM ATM-MIB;
+
+cabletron OBJECT IDENTIFIER ::= { enterprises 52 }
+
+mibs OBJECT IDENTIFIER ::= { cabletron 4 }
+
+ctron OBJECT IDENTIFIER ::= { mibs 1 }
+
+ctDataLink OBJECT IDENTIFIER ::= { ctron 2 }
+
+ctSwitch OBJECT IDENTIFIER ::= { ctDataLink 11 }
+
+ctsfSwitch OBJECT IDENTIFIER ::= { ctSwitch 1 }
+
+ctSFCS OBJECT IDENTIFIER ::= { ctsfSwitch 1 }
+
+
+-- The SFCS Groups.
+
+-- The SFCS System Groups (switch system)
+sfcsSystem OBJECT IDENTIFIER ::= { ctSFCS 1 }
+ sfcsSysConfig OBJECT IDENTIFIER ::= { sfcsSystem 1 }
+ sfcsSysStatus OBJECT IDENTIFIER ::= { sfcsSystem 2 }
+ sfcsSysSystemCfg OBJECT IDENTIFIER ::= { sfcsSystem 3 }
+ sfcsSysBPCfg OBJECT IDENTIFIER ::= { sfcsSystem 4 }
+
+-- All groups from here on represent a single switch module
+
+-- The SFCS Engine Groups
+sfcsEngine OBJECT IDENTIFIER ::= { ctSFCS 2 }
+ sfcsConfig OBJECT IDENTIFIER ::= { sfcsEngine 1 }
+ sfcsStatus OBJECT IDENTIFIER ::= { sfcsEngine 2 }
+ sfcsUPCEngine OBJECT IDENTIFIER ::= { sfcsEngine 3 }
+ sfcsStatisticsEngine OBJECT IDENTIFIER ::= { sfcsEngine 4 }
+ sfcsPacketDiscardEngine OBJECT IDENTIFIER ::= { sfcsEngine 5 }
+
+
+-- The SFCS ANIM Groups
+sfcsANIM OBJECT IDENTIFIER ::= { ctSFCS 3 }
+ sfcsANIMConfig OBJECT IDENTIFIER ::= { sfcsANIM 1 }
+ sfcsANIMStatistics OBJECT IDENTIFIER ::= { sfcsANIM 2 }
+ sfcsANIMPic OBJECT IDENTIFIER ::= { sfcsANIM 3 }
+
+
+-- The SFCS Interface Groups
+sfcsInterface OBJECT IDENTIFIER ::= { ctSFCS 4 }
+ sfcsInterfaceConfig OBJECT IDENTIFIER ::= { sfcsInterface 1 }
+ sfcsInterfaceStatistics OBJECT IDENTIFIER ::= { sfcsInterface 2 }
+
+
+-- The SFCS Queue Groups
+sfcsQueue OBJECT IDENTIFIER ::= { ctSFCS 5 }
+ sfcsQueueConfig OBJECT IDENTIFIER ::= { sfcsQueue 1 }
+ sfcsQueueStatistics OBJECT IDENTIFIER ::= { sfcsQueue 2 }
+
+
+-- The SFCS Connection Groups
+sfcsConnection OBJECT IDENTIFIER ::= { ctSFCS 7 }
+ sfcsConnectionConfig OBJECT IDENTIFIER ::= { sfcsConnection 1 }
+ sfcsConnectionStatistics OBJECT IDENTIFIER ::= { sfcsConnection 2 }
+ sfcsConnectionError OBJECT IDENTIFIER ::= { sfcsConnection 3 }
+
+
+-- The SFCS Connection API Group
+sfcsConnectionAPI OBJECT IDENTIFIER ::= { ctSFCS 8 }
+
+
+-- The SFCS CTM Groups
+sfcsCTM OBJECT IDENTIFIER ::= { ctSFCS 9 }
+ sfcsCTMInterfaceConfig OBJECT IDENTIFIER ::= { sfcsCTM 1 }
+ sfcsCTMInterfaceStatistics OBJECT IDENTIFIER ::= { sfcsCTM 2 }
+ sfcsCTMQueueConfig OBJECT IDENTIFIER ::= { sfcsCTM 3 }
+ sfcsCTMQueueStatistics OBJECT IDENTIFIER ::= { sfcsCTM 4 }
+
+
+-- The SFCS Bandwidth Managment Groups
+sfcsBWMgr OBJECT IDENTIFIER ::= { ctSFCS 12 }
+ sfcsBwNims OBJECT IDENTIFIER ::= { sfcsBWMgr 1 }
+ sfcsBwPorts OBJECT IDENTIFIER ::= { sfcsBWMgr 2 }
+ sfcsBwPortPools OBJECT IDENTIFIER ::= { sfcsBWMgr 3 }
+ sfcsBuffPools OBJECT IDENTIFIER ::= { sfcsBWMgr 4 }
+
+
+-- The ANIM Proxy Groups
+sfcsProxy OBJECT IDENTIFIER ::= { ctSFCS 13 }
+ sfcsProxyConfig OBJECT IDENTIFIER ::= { sfcsProxy 1 }
+ sfcsProxyTrans OBJECT IDENTIFIER ::= { sfcsProxy 2 }
+ sfcsProxyRead OBJECT IDENTIFIER ::= { sfcsProxy 3 }
+
+
+
+sfcsSysConfigTable OBJECT IDENTIFIER ::= { sfcsSysConfig 1 }
+
+sfcsSysConfigEnt OBJECT IDENTIFIER ::= { sfcsSysConfigTable 1 }
+
+sfcsSysConfigAdminStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ enabled(1), -- startup the SFCS
+ disabled(2), -- shutdown the SFCS
+ other(3) -- none of the following
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Sets the administrative state of the SFCS switching
+ services for this virtual switch. This controls the
+ SFCS state at a chassis level. Regardless of the
+ per-interface state of each SFCS switching element
+ and the state of active connections, writing the value
+ disabled(2) will cause the entire switch to immediately
+ shutdown.
+ enabled(1) -- startup the SFCS
+ disabled(2) -- shutdown the SFCS
+ other(3) -- none of the following"
+ ::= { sfcsSysConfigEnt 1 }
+
+sfcsSysConfigOperStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ enabled(1), -- running
+ disabled(2), -- not running
+ other(3), -- none of the following
+ pending-disable(4), -- shut-down in progress
+ pending-enable(5), -- start-up in progress
+ invalid-config(6) -- not running,invalid config
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the current operating condition of this switch.
+ enabled(1) -- running
+ disabled(2) -- not running
+ other(3) -- none of the following
+ pending-disable(4) -- shut-down in progress
+ pending-enable(5) -- start-up in progress
+ invalid-config(6) -- not running,invalid config"
+ ::= { sfcsSysConfigEnt 2 }
+
+sfcsSysConfigOperTime OBJECT-TYPE
+ SYNTAX TimeTicks
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the amount of time (# of time ticks) that
+ this switch system has been in its current operational
+ state."
+ ::= { sfcsSysConfigEnt 3 }
+
+sfcsSysConfigLastChange OBJECT-TYPE
+ SYNTAX TimeTicks
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the last time a change was made to the
+ configuration entry for this switch."
+ ::= { sfcsSysConfigEnt 4 }
+
+sfcsSysConfigSwitchCapacity OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the maximum front panel bandwidth based on current
+ hardware configuration of the switch in Mbps"
+ ::= { sfcsSysConfigEnt 5 }
+
+sfcsSysConfigMaxCnxEntries OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the maximum number of connections which
+ can be established on this switch."
+ ::= { sfcsSysConfigEnt 6 }
+
+sfcsSysConfigMaxStatEntries OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the maximum number of stats enabled VCs for this
+ switch."
+ ::= { sfcsSysConfigEnt 7 }
+
+sfcsSysConfigMaxUpcEntries OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the maximum number of UPC enabled VCs for this
+ switch."
+ ::= { sfcsSysConfigEnt 8 }
+
+sfcsSysConfigNumberANIMS OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the number of ATM Network Inteface Modules
+ currently configured on this switch."
+ ::= { sfcsSysConfigEnt 9 }
+
+sfcsSysConfigInterfaceCapability OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the total bandwidth capability(of the engine)
+ for this switch expressed in Mbps."
+ ::= { sfcsSysConfigEnt 10 }
+
+sfcsSysConfigTypeofSwitch OBJECT-TYPE
+ SYNTAX INTEGER {
+ other (1),
+ sfcellswitch (2),
+ sfpacketswitch (3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates what type of switch this is.
+ other(1)
+ sfcellswitch(2)
+ sfpacketswitch(3)"
+ ::= { sfcsSysConfigEnt 11 }
+
+sfcsSysConfigPolicingSupport OBJECT-TYPE
+ SYNTAX TruthValue
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates whether or not this switch supports policing.
+ supported(1)
+ not supported(2)"
+ ::= { sfcsSysConfigEnt 12 }
+
+sfcsSysConfigPnniNsapPrefix OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(13))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This is the 13 byte NSAP prefix to use
+ with address registration."
+ ::= { sfcsSysConfigEnt 13 }
+
+sfcsSysConfigPnniNodeLevel OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This is the PNNI node level value.
+ The range can be from 0 to 104."
+ ::= { sfcsSysConfigEnt 14 }
+
+sfcsSysConfigPnniAddessingMode OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This is the PNNI addressing mode - that
+ can range from 0 to 2.
+ 0 - Auto Mode using MAC
+ 1 - Auto Mode using board#
+ 2 - Manual "
+ ::= { sfcsSysConfigEnt 15 }
+
+sfcsSysConfigPnniAddessingAdmnStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This is the PNNI addressing admn status.
+ Down - 2. Up - 1."
+ ::= { sfcsSysConfigEnt 16 }
+
+sfcsSysConfigFMVer OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(8))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This is the Firmware Revision of the switch."
+ ::= { sfcsSysConfigEnt 17 }
+
+sfcsSysConfigCTMSlotMask OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This is the slot mask for all ctm boards in the chassis.
+ The least significant bit represents slot 1."
+ ::= { sfcsSysConfigEnt 18 }
+
+sfcsSysConfigMaxfreecva OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This is the maximum number of CAC connection blocks that
+ CAC will allow on its free list. The default is 1024. If too low
+ CAC performance will degrade (thrashing control blocks), If too high,
+ memory exhaustion may occur.
+ "
+ ::= { sfcsSysConfigEnt 19 }
+
+sfcsSysConfigUBR OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "For the set operation: UBR_Cfg is set across all boards in the
+ chassis (that are operational and manageable).
+ For the get operation: UBR_Cfg setting is retrived from the
+ current chassis manager only (one slot only).
+ IF boards are introduced or re-introduced to the chassis their
+ UBR value will be 0. In order to insure a required UBR_Cfg value
+ the set operation should be proformed after slot insertions or
+ re-insertions are completed to the chassis. "
+ ::= { sfcsSysConfigEnt 20 }
+
+
+-- SFCS System Status Table
+-- This table contains the objects that pertain to the operational status
+-- of a virtual switch.
+
+
+sfcsSysStatusTable OBJECT IDENTIFIER ::= { sfcsSysStatus 1 }
+
+sfcsSysStatusEnt OBJECT IDENTIFIER ::= { sfcsSysStatusTable 1 }
+
+sfcsSysStatusTdmCellCount OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the total number of cells being transfered
+ across the TDM for the entire switch."
+ ::= { sfcsSysStatusEnt 1 }
+
+sfcsSysStatusTdmUtilization OBJECT-TYPE
+ SYNTAX INTEGER (0..100)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the total percentage TDM utilization for the switch."
+ ::= { sfcsSysStatusEnt 2 }
+
+sfcsSysStatusCurrCnxEntries OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the current number of connection entries for
+ this switch."
+ ::= { sfcsSysStatusEnt 3 }
+
+sfcsSysStatusCurrUPCEntries OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the current number of UPC entries for this
+ switch."
+ ::= { sfcsSysStatusEnt 4 }
+
+sfcsSysStatusCurrStatsEntries OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the current number of statistics entries for
+ this switch."
+ ::= { sfcsSysStatusEnt 5 }
+
+sfcsSysStatusAllocatedBw OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the current allocated bandwidth of the switch in
+ bits per second."
+ ::= { sfcsSysStatusEnt 6 }
+
+
+
+-- SFCS System Configuration Table set up as a SYSTEM MIB
+-- This table contains the objects that pertain to the setup and
+-- configuration of the virtual switch.
+
+sfcsSysSystemCfgTable OBJECT IDENTIFIER ::= { sfcsSysSystemCfg 1 }
+
+sfcsSysSystemCfgEnt OBJECT IDENTIFIER ::= { sfcsSysSystemCfgTable 1 }
+
+sfcsSysConfigAdminReset OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1), -- none of the following
+ reset(2) -- force a reset
+ }
+
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Resets this virtual switch. Writing a value of
+ reset(2) will force a restart of the entire switch,
+ without any graceful shutdown. Any active
+ connections or services will be interrupted.
+ other(1) -- none of the following
+ reset(2) -- force a reset"
+ ::= { sfcsSysSystemCfgEnt 1 }
+
+sfcsSysConfigATOMPersistance OBJECT-TYPE
+ SYNTAX INTEGER {
+ enabled (1),
+ disabled (2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This enables or disables ATOM mib persistance.
+ enabled(1)
+ disabled(2)"
+ ::= { sfcsSysSystemCfgEnt 2 }
+
+sfcsSysConfigVcSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This entry is the size of VCs allocated for all
+ VPs in the switch."
+ ::= { sfcsSysSystemCfgEnt 3 }
+
+sfcsSysConfigPowerUpDiags OBJECT-TYPE
+ SYNTAX INTEGER {
+ enabled (1),
+ disabled (2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This enables or disables power up diags.
+ enabled(1)
+ disabled(2)"
+ ::= { sfcsSysSystemCfgEnt 4 }
+
+
+-- SFCS System Back Plane Table set up as a SYSTEM MIB
+-- This table contains the objects that pertain to the setup and
+-- configuration of the virtual switch.
+
+sfcsSysBPTable OBJECT IDENTIFIER ::= { sfcsSysBPCfg 1 }
+
+sfcsSysBPEnt OBJECT IDENTIFIER ::= { sfcsSysBPTable 1 }
+
+sfcsSysBPClkSelect OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This enables one of two backplane clocks from any slot.
+ A valid entry is any number that correspond to a slot
+ having a board supporting this mib. A write to this mib
+ will fail if the board with the number selected is deriving
+ its clock from the backplane. A value of 0 indicates that no
+ board is driving the backplane."
+ ::= { sfcsSysBPEnt 1 }
+
+
+-- From here forward, all objects represent the switch modules.
+
+
+-- SFCS Engine Group
+-- This group contains the objects that pertain to switching engines at
+-- a switch module, slot-instanced level. This group contains four sub-groups:
+-- configuration status, statistics, UPC Engine, and statistics engine.
+
+
+-- SFCS Engine Configuration Table
+-- This table contains the objects that pertain to the setup and
+-- configuration of a single SFCS module.
+
+sfcsConfigTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SfcsConfigEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "This table contains the configuration and administrative
+ information for each SFCS module. Essentially, a
+ separate SFCS instance exists for each switch module.
+ If SFCS is not configured on a module, than an entry
+ will not exist."
+ ::= { sfcsConfig 1 }
+
+sfcsConfigEntry OBJECT-TYPE
+ SYNTAX SfcsConfigEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Each entry specifies the SFCS configuration for the
+ SFCS module."
+ INDEX { sfcsConfigSlotIndex }
+ ::= { sfcsConfigTable 1 }
+
+SfcsConfigEntry ::=
+ SEQUENCE {
+ sfcsConfigSlotIndex INTEGER,
+ sfcsConfigAdminStatus INTEGER,
+ sfcsConfigAdminReset INTEGER,
+ sfcsConfigOperStatus INTEGER,
+ sfcsConfigOperTime TimeTicks,
+ sfcsConfigLastChange TimeTicks,
+ sfcsConfigVersion INTEGER,
+ sfcsConfigMibRev DisplayString,
+ sfcsConfigSwitchHostPort INTEGER,
+ sfcsConfigHostCtrlATMAddr OCTET STRING,
+ sfcsConfigSwitchCapacity INTEGER,
+ sfcsConfigMaxCnxEntries INTEGER,
+ sfcsConfigMaxStatEntries INTEGER,
+ sfcsConfigMaxUpcEntries INTEGER,
+ sfcsConfigNumberANIMS INTEGER,
+ sfcsConfigBwCapability INTEGER,
+ sfcsConfigMasterClock1Source INTEGER,
+ sfcsConfigMasterClock2Source INTEGER,
+ sfcsConfigMasterClock1Standby INTEGER,
+ sfcsConfigMasterClock2Standby INTEGER
+ }
+
+sfcsConfigSlotIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The primary index to the SFCS switch table. This
+ identifies the chassis slot number for this switch
+ module."
+ ::= { sfcsConfigEntry 1 }
+
+sfcsConfigAdminStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ enabled(1), -- startup the SFCS
+ disabled(2), -- shutdown the SFCS
+ other(3) -- none of the following
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Sets the administrative state of the SFCS switching
+ services for this SFCS module. This controls the
+ SFCS state at a module level. Regardless of the
+ per-interface state of each SFCS switching interface
+ and the state of active connections, writing the value
+ disabled(2) will cause the SFCS to immediately
+ shutdown. A gracefull shutdown will be attempted.
+ enabled(1) -- startup the SFCS
+ disabled(2) -- shutdown the SFCS
+ other(3) -- none of the following"
+ ::= { sfcsConfigEntry 2 }
+
+sfcsConfigAdminReset OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1), -- none of the following
+ reset(2) -- force a reset
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Resets this SFCS module. Writing a value of
+ reset(2) will force a soft restart of the SFCS
+ without any graceful shutdown. Any active
+ connections or services will be interrupted.
+ other(1) -- none of the following
+ reset(2) -- force a reset"
+ ::= { sfcsConfigEntry 3 }
+
+sfcsConfigOperStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ enabled(1), -- running
+ disabled(2), -- not running
+ other(3), -- none of the following
+ pending-disable(4), -- shut-down in progress
+ pending-enable(5), -- start-up in progress
+ invalid-config(6) -- not running,invalid config
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the current operating condition of the SFCS
+ module.
+ enabled(1) -- running
+ disabled(2) -- not running
+ other(3) -- none of the following
+ pending-disable(4) -- shut-down in progress
+ pending-enable(5) -- start-up in progress
+ invalid-config(6) -- not running,invalid config"
+ ::= { sfcsConfigEntry 4 }
+
+sfcsConfigOperTime OBJECT-TYPE
+ SYNTAX TimeTicks
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the amount of time (# of time ticks) that this
+ SFCS module has been in its current operational state."
+ ::= { sfcsConfigEntry 5 }
+
+sfcsConfigLastChange OBJECT-TYPE
+ SYNTAX TimeTicks
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the last time a change was made to the
+ configuration entry for this SFCS switch module."
+ ::= { sfcsConfigEntry 6 }
+
+sfcsConfigVersion OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the current revision level of the SFCS MIB
+ for this switch module expressed as an integer."
+ ::= { sfcsConfigEntry 7 }
+
+sfcsConfigMibRev OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates in textual format the current revision level
+ of the Cabletron SFCS MIB for this switch module."
+ ::= { sfcsConfigEntry 8 }
+
+sfcsConfigSwitchHostPort OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the switch port that is attached to the host."
+ ::= { sfcsConfigEntry 9 }
+
+sfcsConfigHostCtrlATMAddr OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the ATM address of the host. (SAR)"
+ ::= { sfcsConfigEntry 10 }
+
+sfcsConfigSwitchCapacity OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the front panel bandwidth based on the hardware
+ that is currently installed, in Mbps.
+ (number of ports and the port type)"
+ ::= { sfcsConfigEntry 11 }
+
+sfcsConfigMaxCnxEntries OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the maximum number of connections which
+ can be established on this switch module."
+ ::= { sfcsConfigEntry 12 }
+
+sfcsConfigMaxStatEntries OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the maximum number of stats enabled VCs for this
+ switch module."
+ ::= { sfcsConfigEntry 13 }
+
+sfcsConfigMaxUpcEntries OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the maximum number of UPC enabled VCs for this
+ switch module."
+ ::= { sfcsConfigEntry 14 }
+
+sfcsConfigNumberANIMS OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the number of ATM Network Inteface Modules
+ currently configured on this switch module."
+ ::= { sfcsConfigEntry 15 }
+
+sfcsConfigBwCapability OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the total bandwidth capability for this
+ switch engine expressed in Mbps."
+ ::= { sfcsConfigEntry 16 }
+
+
+sfcsConfigMasterClock1Source OBJECT-TYPE
+
+ SYNTAX INTEGER{
+ anim-one-clk(1),
+ anim-two-clk(2),
+ anim-three-clk(3),
+ anim-four-clk(4),
+ backplane-one(5),
+ backplane-two(6)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the clocking source for MasterClock1 on each board.
+ The write will fail if it is also currently the source of the
+ backplane. The write will also fail if the board does not support
+ backplane clocking."
+
+ ::= { sfcsConfigEntry 17 }
+
+sfcsConfigMasterClock2Source OBJECT-TYPE
+
+ SYNTAX INTEGER{
+ anim-one-clk(1),
+ anim-two-clk(2),
+ anim-three-clk(3),
+ anim-four-clk(4),
+ backplane-one(5),
+ backplane-two(6)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the clocking source for MasterClock2 on each board.
+ The write will fail if it is also currently the source of the
+ backplane. The write will also fail if the board does not support
+ backplane clocking."
+
+ ::= { sfcsConfigEntry 18 }
+
+
+sfcsConfigMasterClock1Standby OBJECT-TYPE
+
+ SYNTAX INTEGER{
+ anim-one-clk(1),
+ anim-two-clk(2),
+ anim-three-clk(3),
+ anim-four-clk(4),
+ backplane-one(5),
+ backplane-two(6),
+ none(7)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the clocking stand-by for MasterClock1 on each board.
+ The write will fail if it is also currently the source of the
+ backplane. The write will also fail if the board does not support
+ backplane clocking. If this value is none(7) and an interrupt on
+ the primary interface for MasterClock1 is received. MasterClock1
+ will switch to that anims local clock."
+
+ ::= { sfcsConfigEntry 19 }
+
+sfcsConfigMasterClock2Standby OBJECT-TYPE
+
+ SYNTAX INTEGER{
+ anim-one-clk(1),
+ anim-two-clk(2),
+ anim-three-clk(3),
+ anim-four-clk(4),
+ backplane-one(5),
+ backplane-two(6),
+ none(7)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the clocking stand-by for MasterClock2 on each board.
+ The write will fail if it is also currently the source of the
+ backplane. The write will also fail if the board does not support
+ backplane clocking. If this value is none(7) and an interrupt on
+ the primary interface for MasterClock1 is received. MasterClock1
+ will switch to that anims local clock."
+
+ ::= { sfcsConfigEntry 20 }
+
+-- SFCS Status Table
+-- This table contains the objects that pertain to the operational status
+-- of a single SFCS module.
+
+sfcsStatusTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SfcsStatusEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "This table contains the status information for each SFCS
+ switch module."
+ ::= { sfcsStatus 1 }
+
+sfcsStatusEntry OBJECT-TYPE
+ SYNTAX SfcsStatusEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Each entry contains the SFCS statistics for the SFCS
+ instance."
+ INDEX { sfcsStatusSlotIndex }
+ ::= { sfcsStatusTable 1 }
+
+SfcsStatusEntry ::=
+ SEQUENCE {
+ sfcsStatusSlotIndex INTEGER,
+ sfcsStatusTdmCellCount OCTET STRING,
+ sfcsStatusTdmUtilization INTEGER,
+ sfcsStatusCurrCnxEntries INTEGER,
+ sfcsStatusCurrUPCEntries INTEGER,
+ sfcsStatusCurrStatsEntries INTEGER,
+ sfcsStatusCurrCtmAgent INTEGER
+ }
+sfcsStatusSlotIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The primary index to the SFCS switch table. This
+ identifies the chassis slot number for this SFCS module."
+ ::= { sfcsStatusEntry 1 }
+
+sfcsStatusTdmCellCount OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the total number of cells being transfered
+ across the TDM for this switch module."
+ ::= { sfcsStatusEntry 2 }
+
+sfcsStatusTdmUtilization OBJECT-TYPE
+ SYNTAX INTEGER (0..100)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the percentage TDM utilization for this switch
+ module."
+ ::= { sfcsStatusEntry 3 }
+
+sfcsStatusCurrCnxEntries OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the current number of connection entries for
+ this switch module."
+ ::= { sfcsStatusEntry 4 }
+
+sfcsStatusCurrUPCEntries OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the current number of UPC entries for this
+ switch module."
+ ::= { sfcsStatusEntry 5 }
+
+sfcsStatusCurrStatsEntries OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the current number of statistics entries for
+ this switch module."
+ ::= { sfcsStatusEntry 6 }
+
+sfcsStatusCurrCtmAgent OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the current board number of
+ the ctm agent for this switch module."
+ ::= { sfcsStatusEntry 7 }
+
+-- SFCS UPC Engine Table
+
+-- This table contains the objects that pertain to UPC Engine
+-- monitoring and statistics of a single instance, slot number indexed
+-- SFCS module.
+
+sfcsUPCTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SfcsUPCEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "This table contains the Usage Parameter Control info
+ for this SFCS module."
+ ::= { sfcsUPCEngine 1 }
+
+sfcsUPCEntry OBJECT-TYPE
+ SYNTAX SfcsUPCEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Each entry contains the UPC data for the SFCS instance."
+ INDEX { sfcsUPCSlotIndex }
+ ::= { sfcsUPCTable 1 }
+
+SfcsUPCEntry ::=
+ SEQUENCE {
+ sfcsUPCSlotIndex INTEGER,
+ sfcsUPCAdminStatus INTEGER,
+ sfcsUPCOperStatus INTEGER,
+ sfcsUPCReset INTEGER,
+ sfcsUPCOperTime TimeTicks
+ }
+sfcsUPCSlotIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The primary index to the SFCS switch table. This
+ identifies the slot number for this SFCS module."
+ ::= { sfcsUPCEntry 1 }
+
+sfcsUPCAdminStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ enabled(1),
+ disabled(2),
+ other(3)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Sets the administrative state of the SFCS module's
+ UPC engine.
+ enabled(1)
+ disabled(2)
+ other(3)"
+ ::= { sfcsUPCEntry 2 }
+
+sfcsUPCOperStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ enabled(1),
+ disabled(2),
+ other(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the operational state of the SFCS module's
+ UPC engine."
+ ::= { sfcsUPCEntry 3 }
+
+sfcsUPCReset OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1),
+ reset(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Resets the UPC engine for this SFCS module.
+ other(1)
+ reset(2)"
+ ::= { sfcsUPCEntry 4 }
+
+sfcsUPCOperTime OBJECT-TYPE
+ SYNTAX TimeTicks
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the amount of time (# of time ticks) that
+ the UPC engine has been active for this switch module."
+ ::= { sfcsUPCEntry 5 }
+
+
+
+-- SFCS Statistics Engine Table
+
+-- This table contains the objects that pertain to Statistics Engine
+-- for a single SFCS module.
+
+sfcsStatsEngineTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SfcsStatsEngineEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "This table contains information for the Statistics engine
+ for a particular switch module."
+ ::= { sfcsStatisticsEngine 1 }
+
+sfcsStatsEngineEntry OBJECT-TYPE
+ SYNTAX SfcsStatsEngineEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Each entry contains the statistics engine data for the
+ SFCS module."
+ INDEX { sfcsStatsEngineSlotIndex }
+ ::= { sfcsStatsEngineTable 1 }
+
+SfcsStatsEngineEntry ::=
+ SEQUENCE {
+ sfcsStatsEngineSlotIndex INTEGER,
+ sfcsStatsEngineAdminStatus INTEGER,
+ sfcsStatsEngineOperStatus INTEGER,
+ sfcsStatsEngineReset INTEGER,
+ sfcsStatsEngineOperTime TimeTicks
+ }
+
+sfcsStatsEngineSlotIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The primary index to the SFCS stats engine table.
+ This identifies the chassis slot number for this SFCS
+ module."
+ ::= { sfcsStatsEngineEntry 1 }
+
+sfcsStatsEngineAdminStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ enabled(1),
+ disabled(2),
+ other(3)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Sets the administrative state of the SFCS switch
+ statistics engine. Writing a value of enabled(1) causes
+ these counters to become active for this SFCS switch
+ instance. Writing a value of disabled(2) causes
+ these counters to become inactive for this SFCS
+ module.
+ enabled(1)
+ disabled(2)
+ other(3)"
+ ::= { sfcsStatsEngineEntry 2 }
+
+sfcsStatsEngineOperStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ enabled(1),
+ disabled(2),
+ other(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the operational state of the SFCS switch
+ statistics engine for this switch module.
+ enabled(1)
+ disabled(2)
+ other(3)"
+ ::= { sfcsStatsEngineEntry 3 }
+
+sfcsStatsEngineReset OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1),
+ reset(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Resets the SFCS switch counters for this SFCS module.
+ Writing a value of reset(2) resets the SFCS switch
+ counters to 0 and causes sfcsStatsEngineOperTime
+ to also be reset to 0.
+ other(1)
+ reset(2)"
+ ::= { sfcsStatsEngineEntry 4 }
+
+sfcsStatsEngineOperTime OBJECT-TYPE
+ SYNTAX TimeTicks
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the amount of time (# of time ticks) that
+ the SFCS switch statistics have been active for this
+ switch module."
+ ::= { sfcsStatsEngineEntry 5 }
+
+
+-- SFCS Packet Discard Engine Table
+
+-- This table contains the objects that pertain to Packet Discard Engine
+-- for a single SFCS module.
+
+sfcsPacketDiscardEngineTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SfcsPacketDiscardEngineEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "This table contains information for the Packet Discard engine
+ for a particular switch module."
+ ::= { sfcsPacketDiscardEngine 1 }
+
+sfcsPacketDiscardEngineEntry OBJECT-TYPE
+ SYNTAX SfcsPacketDiscardEngineEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Each entry contains the packet discard engine data for the
+ SFCS module."
+ INDEX { sfcsPacketDiscardEngineSlotIndex }
+ ::= { sfcsPacketDiscardEngineTable 1 }
+
+SfcsPacketDiscardEngineEntry ::=
+ SEQUENCE {
+ sfcsPacketDiscardEngineSlotIndex INTEGER,
+ sfcsPacketDiscardEngineAdminStatus INTEGER,
+ sfcsPacketDiscardEngineOperStatus INTEGER,
+ sfcsPacketDiscardEngineReset INTEGER,
+ sfcsPacketDiscardEngineEPDPercentage INTEGER,
+ sfcsPacketDiscardEngineOperTime TimeTicks
+ }
+
+sfcsPacketDiscardEngineSlotIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The primary index to the SFCS packet discard engine table.
+ This identifies the chassis slot number for this SFCS
+ module."
+ ::= { sfcsPacketDiscardEngineEntry 1 }
+
+sfcsPacketDiscardEngineAdminStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ enabled(1),
+ disabled(2),
+ other(3)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Sets the administrative state of the SFCS switch
+ packet discard engine. Writing a value of enabled(1) causes
+ these packet discard registers to become active for this SFCS switch
+ instance. Writing a value of disabled(2) causes
+ these packet discard registers to become inactive for this SFCS
+ module.
+ enabled(1)
+ disabled(2)
+ other(3)"
+ ::= { sfcsPacketDiscardEngineEntry 2 }
+
+sfcsPacketDiscardEngineOperStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ enabled(1),
+ disabled(2),
+ other(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the operational state of the SFCS switch
+ packet discard engine for this switch module.
+ enabled(1)
+ disabled(2)
+ other(3)"
+ ::= { sfcsPacketDiscardEngineEntry 3 }
+
+sfcsPacketDiscardEngineReset OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1),
+ reset(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Resets the SFCS switch registers for this SFCS module.
+ Writing a value of reset(2) resets the SFCS switch packet
+ discard registers to 0 and causes sfcsPacketDiscardEngineOperTime
+ to also be reset to 0.
+ other(1)
+ reset(2)"
+ ::= { sfcsPacketDiscardEngineEntry 4 }
+
+sfcsPacketDiscardEngineEPDPercentage OBJECT-TYPE
+ SYNTAX INTEGER (0..100)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Sets the Early Packet Discard threshold percentage for every
+ port, and every priority on a single blade."
+ ::= { sfcsPacketDiscardEngineEntry 5 }
+
+sfcsPacketDiscardEngineOperTime OBJECT-TYPE
+ SYNTAX TimeTicks
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the amount of time (# of time ticks) that
+ the SFCS switch packet discard engine has been active for this
+ switch module."
+ ::= { sfcsPacketDiscardEngineEntry 6 }
+
+
+-- SFCS Switching ANIM Group
+-- This group contains the managed objects used to setup and
+-- configure the SFCS ANIMS. This group contains two sub-groups:
+-- configuration status and statistics.
+
+
+-- SFCS ANIM Configuration Status Table
+-- This table contains the managed objects used to set-up and configure
+-- each SFCS ANIM.
+
+sfcsANIMConfigTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SfcsANIMConfigEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "This table contains the configuration information for
+ each SFCS ANIM instance."
+ ::= { sfcsANIMConfig 1 }
+
+sfcsANIMConfigEntry OBJECT-TYPE
+ SYNTAX SfcsANIMConfigEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Each entry contains the SFCS config info for the SFCS
+ instance."
+ INDEX { sfcsANIMConfigANIMIndex }
+ ::= { sfcsANIMConfigTable 1 }
+
+SfcsANIMConfigEntry ::=
+ SEQUENCE {
+ sfcsANIMConfigANIMIndex INTEGER,
+ sfcsANIMConfigAdminStatus INTEGER,
+ sfcsANIMConfigOperStatus INTEGER,
+ sfcsANIMConfigANIMType OBJECT IDENTIFIER,
+ sfcsANIMConfigNumInterfaces INTEGER,
+ sfcsANIMConfigLineRate INTEGER,
+ sfcsANIMConfigToMB INTEGER,
+ sfcsANIMConfigMBClockSelect INTEGER
+
+ }
+
+sfcsANIMConfigANIMIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This index specifies which ANIM we are dealing
+ with. This reference is in the same format as
+ MIB II's InterfaceIndex."
+ ::= { sfcsANIMConfigEntry 1 }
+
+sfcsANIMConfigAdminStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ enabled(1),
+ disabled(2),
+ other(3)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Sets the administrative state of the SFCS switch
+ ANIM.
+ enabled(1)
+ disabled(2)
+ other(3)"
+ ::= { sfcsANIMConfigEntry 2 }
+
+sfcsANIMConfigOperStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ enabled(1),
+ disabled(2),
+ other(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the operational state of the SFCS switch
+ ANIM for this SFCS ANIM instance.
+ enabled(1)
+ disabled(2)
+ other(3)"
+ ::= { sfcsANIMConfigEntry 3 }
+
+sfcsANIMConfigANIMType OBJECT-TYPE
+ SYNTAX OBJECT IDENTIFIER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the type of physical interface for this
+ ANIM. The types are described in ctron.oids"
+ ::= { sfcsANIMConfigEntry 4 }
+
+sfcsANIMConfigNumInterfaces OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the number of operational interfaces for
+ this ANIM."
+ ::= { sfcsANIMConfigEntry 5 }
+
+sfcsANIMConfigLineRate OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the line rate per port for this ANIM in
+ Mbps."
+ ::= { sfcsANIMConfigEntry 6 }
+
+
+sfcsANIMConfigToMB OBJECT-TYPE
+ SYNTAX INTEGER {
+ local-anim-clock(1),
+ port-one-clock(2),
+ port-two-clock(3),
+ port-three-clock(4),
+ port-four-clock(5)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This is the ANIM clock source to board."
+ ::= { sfcsANIMConfigEntry 7 }
+
+sfcsANIMConfigMBClockSelect OBJECT-TYPE
+ SYNTAX INTEGER {
+ master-clk-one(1),
+ master-clk-two(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This indicates the ANIM clock source."
+ ::= { sfcsANIMConfigEntry 8 }
+
+
+
+
+-- SFCS ANIM Stats Tables
+-- This table contains the managed objects used to keep track of transmit
+-- and receive counts and bandwidth for each SFCS ANIM.
+
+
+sfcsANIMStatsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SfcsANIMStatsEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "This table contains the statistics information for
+ each SFCS ANIM instance."
+ ::= { sfcsANIMStatistics 1 }
+
+sfcsANIMStatsEntry OBJECT-TYPE
+ SYNTAX SfcsANIMStatsEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Each entry contains the SFCS statistics for the SFCS
+ instance."
+ INDEX { sfcsANIMStatsANIMIndex }
+ ::= { sfcsANIMStatsTable 1 }
+
+SfcsANIMStatsEntry ::=
+ SEQUENCE {
+ sfcsANIMStatsANIMIndex INTEGER,
+ sfcsANIMStatsRxCells OCTET STRING,
+ sfcsANIMStatsTxCells OCTET STRING
+ }
+
+sfcsANIMStatsANIMIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The primary index which specifies which ANIM instance
+ we are dealing with. This index is formatted like
+ MIB II's Interface Index."
+ ::= { sfcsANIMStatsEntry 1 }
+
+sfcsANIMStatsRxCells OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the number of cells received from this
+ ANIM's interfaces."
+ ::= { sfcsANIMStatsEntry 2 }
+
+sfcsANIMStatsTxCells OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the number of cells transmitted from
+ this ANIM's interfaces."
+ ::= { sfcsANIMStatsEntry 3 }
+
+-- SFCS ANIM Pic Table
+-- This table contains the managed objects used to keep track of
+-- the PIC info for each SFCS ANIM.
+
+
+sfcsANIMPicTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SfcsANIMPicEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "This table contains the PIC information for
+ each SFCS ANIM instance."
+ ::= { sfcsANIMPic 1 }
+
+sfcsANIMPicEntry OBJECT-TYPE
+ SYNTAX SfcsANIMPicEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Each entry contains the SFCS PIC info for the SFCS
+ instance."
+ INDEX { sfcsANIMPicIndex }
+ ::= { sfcsANIMPicTable 1 }
+
+SfcsANIMPicEntry ::=
+ SEQUENCE {
+ sfcsANIMPicSlot INTEGER,
+ sfcsANIMPicIndex INTEGER,
+ sfcsANIMPicLocation OBJECT IDENTIFIER,
+ sfcsANIMPicStatus INTEGER,
+ sfcsANIMPicVersion DisplayString,
+ sfcsANIMPicModuleType OBJECT IDENTIFIER,
+ sfcsANIMPicMfgPN DisplayString,
+ sfcsANIMPicMfgSN DisplayString,
+ sfcsANIMPicMfgPartNumb DisplayString,
+ sfcsANIMPicMfgSerialNumb DisplayString,
+ sfcsANIMPicMfgReworkLocation DisplayString,
+ sfcsANIMPicMfgMfgLocation DisplayString,
+ sfcsANIMPicMfgDateCode DisplayString,
+ sfcsANIMPicMfgRevisionCode DisplayString,
+ sfcsANIMPicTLPN DisplayString,
+ sfcsANIMPicTLSN DisplayString,
+ sfcsANIMPicTLPartNumb DisplayString,
+ sfcsANIMPicTLSerialNumb DisplayString,
+ sfcsANIMPicTLReworkLocation DisplayString,
+ sfcsANIMPicTLMfgLocation DisplayString,
+ sfcsANIMPicTLDateCode DisplayString,
+ sfcsANIMPicTLRevisionCode DisplayString,
+ sfcsANIMPicTLPcbRevision DisplayString,
+ sfcsANIMPicMacAddr OCTET STRING,
+ sfcsANIMPicNumbRsvdAddrs INTEGER,
+ sfcsANIMPicBoardLevelRevision DisplayString,
+ sfcsANIMPicModuleTypeString DisplayString,
+ sfcsANIMPicDcDcConverterType DisplayString,
+ sfcsANIMPicDcDcConverterInputPower DisplayString,
+ sfcsANIMPicSmb1PromVersion DisplayString
+ }
+
+sfcsANIMPicSlot OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Specific slot which the module that realizes this PIC
+ resides. If the PIC is associated with the chassis
+ and not a specific module then this value will be 0."
+ ::= { sfcsANIMPicEntry 1 }
+
+sfcsANIMPicIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Uniquely identifies the instance of a PIC in a particular
+ slot."
+ ::= { sfcsANIMPicEntry 2 }
+
+sfcsANIMPicLocation OBJECT-TYPE
+ SYNTAX OBJECT IDENTIFIER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Defines location of the PIC chip. This takes on any of
+ the encoding values defined below for backplane, module,
+ daughter board, brim."
+ ::= { sfcsANIMPicEntry 3 }
+
+sfcsANIMPicStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1),
+ present(2),
+ notPresent(3),
+ checkSum(4),
+ error(5),
+ limited(6)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Provides the status of the specific PIC chip. the values
+ are defined as follows:
+ other(1) - firmware can not determine status
+ present(2) - PIC seems to be functional
+ notPresent(3) - PIC not found but expected
+ checkSum(4) - A check sum error occured
+ error(5) - An undefined error condition exists.
+ limited(6) - A limited PIC implementation only
+ type code information is present."
+ ::= { sfcsANIMPicEntry 4 }
+
+sfcsANIMPicVersion OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(2))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Reflects the version of the PIC implementation that this
+ PIC conforms to. This has the format x.yy . If non-existent,
+ this object will be set to all blanks(ascii 32)."
+ ::= { sfcsANIMPicEntry 5 }
+
+sfcsANIMPicModuleType OBJECT-TYPE
+ SYNTAX OBJECT IDENTIFIER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Defines the standard module type value as defined in
+ ctron-oids."
+ ::= { sfcsANIMPicEntry 6 }
+
+sfcsANIMPicMfgPN OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(9))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Describes the manufacturing level part number of the module
+ associated with this PIC. This information is encoded as
+ follows:
+ 7 Characters Part Number
+ 2 Characters Rework Location.
+ If any field of this object is non-existent, it will be set
+ to all blanks(ascii 32)."
+ ::= { sfcsANIMPicEntry 7 }
+
+sfcsANIMPicMfgSN OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(12))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Describes the manufacturing level serial number of the module
+ associated with this PIC. This information is encoded as
+ follows:
+ 3 bytes - Date code (year/week)
+ 4 bytes - Serial number
+ 2 bytes - Manufacture location
+ 3 bytes - Board level revision
+ If any field of this object is non-existent, it will be
+ set to all blanks(ascii 32)."
+ ::= { sfcsANIMPicEntry 8 }
+
+sfcsANIMPicMfgPartNumb OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(7))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This object presents the part number portion of the
+ ctPicMfgPN object. This object contains the same information
+ however in a more human readable format. If non-existent,
+ this object will be set to all blanks(ascii 32)."
+ ::= { sfcsANIMPicEntry 9 }
+
+sfcsANIMPicMfgSerialNumb OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(4))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This object presents the serial number portion of the
+ ctPicMfgSN object. This object contains the same information
+ however in a more human readable format. If non-existent,
+ this object will be set to all blanks(ascii 32)."
+ ::= { sfcsANIMPicEntry 10 }
+
+sfcsANIMPicMfgReworkLocation OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(2))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The 2 character code that defines the location this
+ module was last reworked. This object contains the same
+ information as presented in ctPicMfgPN object however
+ in a more human readable format. If non-existent, this
+ object will be set to all blanks(ascii 32)."
+ ::= { sfcsANIMPicEntry 11 }
+
+sfcsANIMPicMfgMfgLocation OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(2))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The two character code that defines the location
+ this module was manufactured at. This object contains the same
+ information as presented in ctPicMfgSN object however
+ in a more human readable format. If non-existent, this object
+ will be set to all blanks(ascii 32)."
+ ::= { sfcsANIMPicEntry 12 }
+
+sfcsANIMPicMfgDateCode OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(3))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The 3 byte date code field when this module was last
+ reworked. This is in year/week format. This object
+ contains the same information as presented in ctPicMfgSN
+ object however in a more human readable format. If
+ non-existent, this object will be set to all blanks(ascii 32)."
+ ::= { sfcsANIMPicEntry 13 }
+
+sfcsANIMPicMfgRevisionCode OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(3))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The 3 character board level revision code field of this
+ module. This object contains the same information as
+ presented in ctPicMfgSN object however in a more human
+ readable format. If non-existent, this object will be set
+ to all blanks (ascii 32)."
+ ::= { sfcsANIMPicEntry 14 }
+
+sfcsANIMPicTLPN OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(9))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Describes the top level part number of the module associated
+ with this PIC. This information is encoded as follows:
+ 7 Characters Part Number
+ 2 Characters Rework Location.
+ If any field of this object is non-existent, it will be set
+ to all blanks(ascii 32)."
+ ::= { sfcsANIMPicEntry 15 }
+
+sfcsANIMPicTLSN OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(12))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Describes the top level serial number of the module
+ associated with this PIC. This information is encoded
+ as follows:
+ 3 bytes - Date code (year/week)
+ 4 bytes - Serial number
+ 2 bytes - Manufacture location
+ 3 bytes - Top level revision
+ If any field of this object is non-existent, it will be
+ set to all blanks(ascii 32)."
+ ::= { sfcsANIMPicEntry 16 }
+
+sfcsANIMPicTLPartNumb OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(7))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This object presents the part number portion of the
+ ctPicTLPN object. This object contains the same information
+ however in a more human readable format. If non-existent,
+ this object will be set to all blanks(ascii 32)."
+ ::= { sfcsANIMPicEntry 17 }
+
+sfcsANIMPicTLSerialNumb OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(4))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This object presents the serial number portion of the
+ ctPicTLSN object. This object contains the same information
+ however in a more human readable format. If non-existent,
+ this object will be set to all blanks(ascii 32)."
+ ::= { sfcsANIMPicEntry 18 }
+
+sfcsANIMPicTLReworkLocation OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(2))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The 2 character code that defines the location this
+ module was last reworked. This object contains the same
+ information as presented in ctPicTLPN object however
+ in a more human readable format. If non-existent, this
+ object will be set to all blanks(ascii 32)."
+ ::= { sfcsANIMPicEntry 19 }
+
+sfcsANIMPicTLMfgLocation OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(2))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The two character code that defines the location
+ this module was manufactured at. This object contains the same
+ information as presented in ctPicTLSN object however
+ in a more human readable format. If non-existent, this object
+ will be set to all blanks(ascii 32)."
+ ::= { sfcsANIMPicEntry 20 }
+
+sfcsANIMPicTLDateCode OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(3))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The 3 byte date code field when this module was last
+ reworked. This is in year/week format. This object
+ contains the same information as presented in ctPicTLSN
+ object however in a more human readable format. If
+ non-existent, this object will be set to all blanks(ascii 32)."
+ ::= { sfcsANIMPicEntry 21 }
+
+sfcsANIMPicTLRevisionCode OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(3))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The 3 character top level revision code field of this module.
+ This object contains the same information as presented in
+ ctPicTLSN object however in a more human readable format.
+ If non-existent, this object will be set to all blanks
+ (ascii 32)."
+ ::= { sfcsANIMPicEntry 22 }
+
+sfcsANIMPicTLPcbRevision OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(8))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Defines the Cabletron revision of the art work for this
+ module. If non-existent, this object will be set to all
+ blanks(ascii 32)."
+ ::= { sfcsANIMPicEntry 23 }
+
+sfcsANIMPicMacAddr OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(0..6))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The base MAC address(ethernet format)assigned to the module.
+ If this field is not used then it should have a value of a
+ zero length string. If non-existent, this object will be set
+ to all blanks(ascii 32)."
+ ::= { sfcsANIMPicEntry 24 }
+
+sfcsANIMPicNumbRsvdAddrs OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of reserved MAC addresses starting at the
+ address as defined in ctPicMacAddr. If no MAC addresses
+ are reserved this object should have a value of 0."
+ ::= { sfcsANIMPicEntry 25 }
+
+sfcsANIMPicBoardLevelRevision OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(3))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Defines the Cabletron board level revision level code for
+ this module. If non-existent, this object will be set to
+ blanks (ascii 32)."
+ ::= { sfcsANIMPicEntry 26 }
+
+sfcsANIMPicModuleTypeString OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(16))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Describes the module associated with this PIC in a
+ human readable format. If non-existent, this object
+ will be set to blanks (ascii 32)."
+ ::= { sfcsANIMPicEntry 27 }
+
+sfcsANIMPicDcDcConverterType OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(12))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Describes the voltage of the installed DCDC Converter
+ input and output lines.
+ If the Module does not contain a DCDC Converter
+ this object will be set to blanks (ascii 32)."
+ ::= { sfcsANIMPicEntry 28 }
+
+sfcsANIMPicDcDcConverterInputPower OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(3))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Describes the maximum allowed input power
+ for the DCDC input line.
+ If the Module does not contain a DCDC Converter
+ this object will be set to blanks (ascii 32)."
+ ::= { sfcsANIMPicEntry 29 }
+
+sfcsANIMPicSmb1PromVersion OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(8))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Describes the current version of the SMB1 prom.
+ If the Module does not contain an SMB1 prom
+ this object will be set to blanks (ascii 32)."
+ ::= { sfcsANIMPicEntry 30 }
+
+
+-- SFCS Switching Interface Group
+-- This group contains the managed objects used to setup and
+-- configure the SFCS interfaces for cell switching and statisics
+-- monitoring. This group contains two sub-groups: configuration
+-- and statistics.
+
+
+-- SFCS Interface Configuration Table
+-- This table contains the managed objects used to set-up and configure
+-- each SFCS switching interface.
+
+sfcsInterfaceConfigTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SfcsInterfaceConfigEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "This table contains the configuration information of each
+ configured SFCS switch interface. If SFCS is not configured
+ on a port, than an entry will not exist."
+ ::= { sfcsInterfaceConfig 1 }
+
+sfcsInterfaceConfigEntry OBJECT-TYPE
+ SYNTAX SfcsInterfaceConfigEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Each entry specifies the SFCS configuration for the SFCS
+ switch interface for which the entry exists."
+ INDEX { sfcsInterfaceConfigInterfaceIndex }
+ ::= { sfcsInterfaceConfigTable 1 }
+
+SfcsInterfaceConfigEntry ::=
+ SEQUENCE {
+ sfcsInterfaceConfigInterfaceIndex INTEGER,
+ sfcsInterfaceConfigType INTEGER,
+ sfcsInterfacePeakBufferUseage INTEGER,
+ sfcsInterfaceConfigNumberOfQueues INTEGER,
+ sfcsInterfaceConfigSigStackID INTEGER,
+ sfcsInterfaceConfigClockingSource INTEGER
+ }
+
+sfcsInterfaceConfigInterfaceIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index which specifies which interface we are
+ dealing with."
+ ::= { sfcsInterfaceConfigEntry 1 }
+
+sfcsInterfaceConfigType OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1),
+ access-port(2),
+ network-port(3),
+ host-mgmt-port(4),
+ host-ctl-port(5)
+ }
+ ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "Sets the type of interface access attribute for the SFCS
+ interfaces. Access ports allow single user or shared
+ access and perform statisics and control; network ports
+ are equivalent to trunk ports with no access control;
+ host management port indicates the (virtual) port to which
+ the (internal) management agent is attached; host control
+ port indicates the port to redirect non-management packets.
+ other(1)
+ access-port(2)
+ network-port(3)
+ host-mgmt-port(4)
+ host-ctl-port(5)"
+ ::= { sfcsInterfaceConfigEntry 2 }
+
+sfcsInterfacePeakBufferUseage OBJECT-TYPE
+ SYNTAX INTEGER (0..100)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "An accumulated snap shot of the current peak queue depth
+ for the configured buffer queues. This information is
+ obtained from a read/reset register."
+ ::= { sfcsInterfaceConfigEntry 3 }
+
+sfcsInterfaceConfigNumberOfQueues OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the number of priority queues configured on this
+ interface."
+ ::= { sfcsInterfaceConfigEntry 4 }
+
+sfcsInterfaceConfigSigStackID OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the user signalling stack ID for this interface."
+ ::= { sfcsInterfaceConfigEntry 5 }
+
+sfcsInterfaceConfigClockingSource OBJECT-TYPE
+ SYNTAX INTEGER {
+ local-anim-clock(1),
+ mother-board-master-clock(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The interface clocking source."
+ ::= { sfcsInterfaceConfigEntry 6 }
+
+
+-- SFCS Switching Interface Statistics Tables
+-- This table contains the objects that specify the packet and byte counters
+-- for each configured SFCS switching interface.
+
+
+sfcsInterfaceStatsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SfcsInterfaceStatsEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "This table contains the cell counts for each
+ SFCS switch interface."
+ ::= { sfcsInterfaceStatistics 1 }
+
+sfcsInterfaceStatsEntry OBJECT-TYPE
+ SYNTAX SfcsInterfaceStatsEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies the SFCS cell counts for the SFCS
+ interface for which this entry exists."
+ INDEX { sfcsInterfaceStatsInterfaceIndex }
+ ::= { sfcsInterfaceStatsTable 1 }
+
+SfcsInterfaceStatsEntry ::=
+ SEQUENCE {
+ sfcsInterfaceStatsInterfaceIndex INTEGER,
+ sfcsInterfaceStatsRxErrors OCTET STRING,
+ sfcsInterfaceStatsVPILookupInvalidErrors OCTET STRING,
+ sfcsInterfaceStatsRxCnxLookupInvalidErrors OCTET STRING,
+ sfcsInterfaceStatsRxCellCnt OCTET STRING,
+ sfcsInterfaceStatsTxCellCnt OCTET STRING,
+ sfcsInterfaceStatsOverflowDropCellCnt OCTET STRING
+ }
+
+sfcsInterfaceStatsInterfaceIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index which specifies which interface we are
+ dealing with."
+ ::= { sfcsInterfaceStatsEntry 1 }
+
+sfcsInterfaceStatsRxErrors OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the number of receive path lookup
+ invalid and out of range errors."
+ ::= { sfcsInterfaceStatsEntry 2 }
+
+sfcsInterfaceStatsVPILookupInvalidErrors OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the number of VPI lookup invalid and out of
+ range errors."
+ ::= { sfcsInterfaceStatsEntry 3 }
+
+sfcsInterfaceStatsRxCnxLookupInvalidErrors OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the number of receive connection lookup
+ invalid errors."
+ ::= { sfcsInterfaceStatsEntry 4 }
+
+sfcsInterfaceStatsRxCellCnt OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the number of receive cells on
+ this interface."
+ ::= { sfcsInterfaceStatsEntry 5 }
+
+
+sfcsInterfaceStatsTxCellCnt OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the number of transmit cells
+ on this interface."
+ ::= { sfcsInterfaceStatsEntry 6 }
+
+
+sfcsInterfaceStatsOverflowDropCellCnt OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the number of cells that were
+ dropped due to queue overflows."
+ ::= { sfcsInterfaceStatsEntry 7 }
+
+
+
+-- SFCS Switch Queue Group
+-- This group contains the managed objects for maintaining SFCS Queues.
+
+-- SFCS Queue Configuration Table
+
+sfcsQueueConfigTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SfcsQueueConfigEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "This table contains the configuration information for
+ all queues on the SFCS."
+ ::= { sfcsQueueConfig 1 }
+
+sfcsQueueConfigEntry OBJECT-TYPE
+ SYNTAX SfcsQueueConfigEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Each entry specifies the queue information for the
+ SFCS switch for which the entry exists."
+ INDEX { sfcsQueueConfigInterfaceIndex, sfcsQueueConfigQueueIndex }
+ ::= { sfcsQueueConfigTable 1 }
+
+SfcsQueueConfigEntry ::=
+ SEQUENCE {
+ sfcsQueueConfigInterfaceIndex INTEGER,
+ sfcsQueueConfigQueueIndex INTEGER,
+ sfcsQueueConfigQueueSize INTEGER,
+ sfcsQueueConfigQueueBandwidth INTEGER,
+ sfcsQueueConfigClpDropThreshold INTEGER,
+ sfcsQueueConfigCongestionThreshold INTEGER,
+ sfcsQueueConfigEFCILowThreshold INTEGER,
+ sfcsQueueConfigRMThreshold INTEGER,
+ sfcsQueueConfigEPDThreshold INTEGER
+ }
+
+sfcsQueueConfigInterfaceIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index which specifies which interface we are
+ dealing with."
+ ::= { sfcsQueueConfigEntry 1 }
+
+sfcsQueueConfigQueueIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index which specifies which transmit queue we
+ are dealing with."
+ ::= { sfcsQueueConfigEntry 2 }
+
+sfcsQueueConfigQueueSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the size of the transmit queue for this
+ queue instance."
+ ::= { sfcsQueueConfigEntry 3 }
+
+sfcsQueueConfigQueueBandwidth OBJECT-TYPE
+ SYNTAX INTEGER (0..100)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the percentage of this interface's bandwidth
+ utilized by this particular queue."
+ ::= { sfcsQueueConfigEntry 4 }
+
+sfcsQueueConfigClpDropThreshold OBJECT-TYPE
+ SYNTAX INTEGER (0..100)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the queue level to start dropping CLP=1
+ cells for this queue. This level is expressed as
+ the percentage of this queue's size."
+ ::= { sfcsQueueConfigEntry 5 }
+
+sfcsQueueConfigCongestionThreshold OBJECT-TYPE
+ SYNTAX INTEGER (0..100)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the level to consider this queue congested.
+ This level is expressed as the percentage of this
+ queue's size."
+ ::= { sfcsQueueConfigEntry 6 }
+
+sfcsQueueConfigEFCILowThreshold OBJECT-TYPE
+ SYNTAX INTEGER (0..100)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the lower threshold used for EFCI for
+ this queue instance. This level is expressed as
+ the percentage of this queue's size."
+ ::= { sfcsQueueConfigEntry 7 }
+
+sfcsQueueConfigRMThreshold OBJECT-TYPE
+ SYNTAX INTEGER (0..100)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the remote management queue threshold expressed
+ as a percentage of the queue's size. When this level is
+ hit, a management message is sent to the sender notifying it
+ to slow down."
+ ::= { sfcsQueueConfigEntry 8 }
+
+sfcsQueueConfigEPDThreshold OBJECT-TYPE
+ SYNTAX INTEGER (0..100)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the Early Packet Discard threshold expressed
+ as a percentage of the queue's size. When this level is
+ exceeded the Transmit ASIC starts to drop all cells entering
+ this queue."
+ ::= { sfcsQueueConfigEntry 9 }
+
+
+-- SFCS Queue Stats Table
+
+sfcsQueueStatsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SfcsQueueStatsEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "This table contains the statistics information for all
+ queues on the SFCS."
+ ::= { sfcsQueueStatistics 1 }
+
+sfcsQueueStatsEntry OBJECT-TYPE
+ SYNTAX SfcsQueueStatsEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Each entry specifies the queue information for the
+ SFCS switch for which the entry exists."
+ INDEX { sfcsQueueStatsInterfaceIndex, sfcsQueueStatsQueue }
+ ::= { sfcsQueueStatsTable 1 }
+
+SfcsQueueStatsEntry ::=
+ SEQUENCE {
+ sfcsQueueStatsInterfaceIndex INTEGER,
+ sfcsQueueStatsQueue INTEGER,
+ sfcsQueueStatsTxClpCellsDiscarded OCTET STRING,
+ sfcsQueueStatsTxCellsDropped OCTET STRING,
+ sfcsQueueStatsQueuePeakLevel INTEGER,
+ sfcsQueueStatsTxCellCnt OCTET STRING
+ }
+
+sfcsQueueStatsInterfaceIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index which specifies which interface we are
+ dealing with."
+ ::= { sfcsQueueStatsEntry 1 }
+
+sfcsQueueStatsQueue OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index which specifies which queue we are
+ dealing with."
+ ::= { sfcsQueueStatsEntry 2 }
+
+sfcsQueueStatsTxClpCellsDiscarded OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the number of cells with CLP=1 that were
+ discarded for this queue instance."
+ ::= { sfcsQueueStatsEntry 3 }
+
+sfcsQueueStatsTxCellsDropped OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the number of cells that overflowed the
+ buffer for this queue instance."
+ ::= { sfcsQueueStatsEntry 4 }
+
+sfcsQueueStatsQueuePeakLevel OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the peak level since last read for this
+ queue instance."
+ ::= { sfcsQueueStatsEntry 5 }
+
+sfcsQueueStatsTxCellCnt OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the transmit cell count on a per queue basis.
+ A value of zero indicates not available"
+ ::= { sfcsQueueStatsEntry 6 }
+
+
+-- The SFCS Connection Group
+
+-- SFCS Switch Connection Config Table
+
+sfcsCnxCfgTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SfcsCnxCfgEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "This table contains the connection configuration
+ information."
+ ::= { sfcsConnectionConfig 1 }
+
+sfcsCnxCfgEntry OBJECT-TYPE
+ SYNTAX SfcsCnxCfgEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Each entry specifies the connection configuration
+ information for the SFCS switch connection instance."
+ INDEX { sfcsCnxCfgCrossConnectIndex,
+ sfcsCnxCfgCrossConnectLowIfIndex,
+ sfcsCnxCfgCrossConnectLowVpi,
+ sfcsCnxCfgCrossConnectLowVci,
+ sfcsCnxCfgCrossConnectHighIfIndex,
+ sfcsCnxCfgCrossConnectHighVpi,
+ sfcsCnxCfgCrossConnectHighVci }
+ ::= { sfcsCnxCfgTable 1 }
+
+SfcsCnxCfgEntry ::=
+ SEQUENCE {
+ sfcsCnxCfgCrossConnectIndex INTEGER,
+ sfcsCnxCfgCrossConnectLowIfIndex INTEGER,
+ sfcsCnxCfgCrossConnectLowVpi INTEGER,
+ sfcsCnxCfgCrossConnectLowVci INTEGER,
+ sfcsCnxCfgCrossConnectHighIfIndex INTEGER,
+ sfcsCnxCfgCrossConnectHighVpi INTEGER,
+ sfcsCnxCfgCrossConnectHighVci INTEGER,
+ sfcsCnxCfgType INTEGER,
+ sfcsCnxCfgTmType INTEGER,
+ sfcsCnxCfgUPCEnable INTEGER,
+ sfcsCnxCfgStatsEnable INTEGER,
+ sfcsCnxCfgStatsTableCounterSizes INTEGER,
+ sfcsCnxCfgOwner INTEGER
+ }
+
+sfcsCnxCfgCrossConnectIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A unique value to identify this cross-connect."
+ ::= { sfcsCnxCfgEntry 1 }
+
+sfcsCnxCfgCrossConnectLowIfIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The value of this object is equal to the low
+ MIB II IfIndex value of the ATM interface port
+ for this cross-connect."
+ ::= { sfcsCnxCfgEntry 2 }
+
+sfcsCnxCfgCrossConnectLowVpi OBJECT-TYPE
+ SYNTAX INTEGER (0..4095)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The value of this object is equal to the low VPI
+ value at the ATM interface associated with the
+ cross-connect that is identified by
+ sfcsCnxCfgCrossConnectIndex."
+ ::= { sfcsCnxCfgEntry 3 }
+
+sfcsCnxCfgCrossConnectLowVci OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The value of this object is equal to the low VCI
+ value at the ATM interface associated with this
+ cross-connect that is identified by
+ sfcsCnxCfgCrossConnectIndex."
+ ::= { sfcsCnxCfgEntry 4 }
+
+sfcsCnxCfgCrossConnectHighIfIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The value of this object is equal to the high
+ MIB II IfIndex value of the ATM interface port
+ for this cross-connect."
+ ::= { sfcsCnxCfgEntry 5 }
+
+sfcsCnxCfgCrossConnectHighVpi OBJECT-TYPE
+ SYNTAX INTEGER (0..4095)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The value of this object is equal to the high VPI
+ value at the ATM interface associated with the
+ cross-connect that is identified by
+ sfcsCnxCfgCrossConnectIndex."
+ ::= { sfcsCnxCfgEntry 6 }
+
+sfcsCnxCfgCrossConnectHighVci OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The value of this object is equal to the high VCI
+ value at the ATM interface associated with this
+ cross-connect that is identified by
+ sfcsCnxCfgCrossConnectIndex."
+ ::= { sfcsCnxCfgEntry 7 }
+
+sfcsCnxCfgType OBJECT-TYPE
+ SYNTAX INTEGER {
+ point-to-point-vpl (1),
+ point-to-mpoint-vpl (2),
+ mpoint-to-mpoint-vpl (3),
+ point-to-point-vcl (4),
+ point-to-mpoint-vcl (5),
+ mpoint-to-mpoint-vcl (6)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the connection type for this VC.
+ point-to-point-vpl(1)
+ point-to-mpoint-vpl(2)
+ mpoint-to-mpoint-vpl(3)
+ point-to-point-vcl(4)
+ point-to-mpoint-vcl(5)
+ mpoint-to-mpoint-vcl(6)"
+ ::= { sfcsCnxCfgEntry 8 }
+
+sfcsCnxCfgTmType OBJECT-TYPE
+ SYNTAX INTEGER {
+ other (1),
+ efci (2),
+ er (3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the type of traffic management used on this VC.
+ other (1)
+ efci (2)
+ er (3)"
+ ::= { sfcsCnxCfgEntry 9 }
+
+sfcsCnxCfgUPCEnable OBJECT-TYPE
+ SYNTAX INTEGER {
+ l-h-upc-enabled (1),
+ l-h-tag-enabled (2),
+ l-h-upc-tag-enabled (3),
+ h-l-upc-enabled (4),
+ l-h-upc-and-h-l-upc-enabled (5),
+ l-h-Tag-and-h-l-upc-enabled (6),
+ l-h-upc-tag-and-h-l-upc-enabled (7),
+ h-l-tag-enabled (8),
+ l-h-upc-and-h-l-tag-enabled (9),
+ l-h-tag-and-h-l-tag-enabled (10),
+ l-h-upc-tag-and-h-l-tag-enabled (11),
+ h-l-upc-tag-enabled (12),
+ l-h-upc-and-h-l-upc-tag-enabled (13),
+ l-h-tag-and-h-l-upc-tag-enabled (14),
+ l-h-upc-tag-and-h-l-upc-tag-enabled (15)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates whether or not UPC policing is enabled on
+ this VC. A VC can be bi-directional or uni-directional.
+ Due to this, the UPC bit is a masking based on directionality.
+ Where direction is in terms of high interface (H) and low
+ interface (L). (Where not specified, assume disabled.)
+ L to H UPC enabled(1)
+ L to H Tagging enabled(2)
+ L to H UPC/Tagging enabled(3)
+ H to L UPC enabled(4)
+ L to H UPC enabled & H to L UPC enabled(5)
+ L to H Tagging enabled & H to L UPC enabled(6)
+ L to H UPC/Tagging enabled & H to L UPC enabled(7)
+ H to L Tagging enabled(8)
+ L to H UPC enabled & H to L Tagging enabled(9)
+ L to H Tagging enabled & H to L Tagging enabled(10)
+ L to H UPC/Tagging enabled & H to L Tagging enabled(11)
+ H to L UPC/Tagging enabled(12)
+ L to H UPC enabled & H to L UPC/Tagging enabled(13)
+ L to H Tagging enabled and H to L UPC/Tagging enabled(14)
+ L to H UPC/Tagging enabled & H to L UPC/Tagging enabled(15)"
+ ::= { sfcsCnxCfgEntry 10 }
+
+sfcsCnxCfgStatsEnable OBJECT-TYPE
+ SYNTAX INTEGER {
+ enabled (1),
+ disabled (2),
+ other (3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates whether statistics will be kept on this VC.
+ enabled(1)
+ disabled(2)
+ other(3)"
+ ::= { sfcsCnxCfgEntry 11 }
+
+sfcsCnxCfgStatsTableCounterSizes OBJECT-TYPE
+ SYNTAX INTEGER {
+ thirtytwobittagcounter (1),
+ thirtytwobitdropcounter (2),
+ sixteenbiteachcounter (3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the size of the drop counter for this VC.
+ thirtytwobittagcounter (1)
+ thirtytwobitdropcounter (2)
+ sixteenbiteachcounter (3)"
+ ::= { sfcsCnxCfgEntry 12 }
+
+sfcsCnxCfgOwner OBJECT-TYPE
+ SYNTAX INTEGER {
+ other (1),
+ own (2),
+ dontown (3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the owner of this cross connect.
+ other(1)
+ own(2)
+ dontown(3)"
+ ::= { sfcsCnxCfgEntry 13 }
+
+
+
+
+
+-- SFCS Switch Connection Stats Table
+
+sfcsCnxStatsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SfcsCnxStatsEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "This table contains the connection configuration
+ information."
+ ::= { sfcsConnectionStatistics 1 }
+
+sfcsCnxStatsEntry OBJECT-TYPE
+ SYNTAX SfcsCnxStatsEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Each entry specifies the connection statistics
+ information for the SFCS switch connection instance."
+ INDEX { sfcsCnxStatsCrossConnectIndex,
+ sfcsCnxStatsCrossConnectLowIfIndex,
+ sfcsCnxStatsCrossConnectLowVpi,
+ sfcsCnxStatsCrossConnectLowVci,
+ sfcsCnxStatsCrossConnectHighIfIndex,
+ sfcsCnxStatsCrossConnectHighVpi,
+ sfcsCnxStatsCrossConnectHighVci }
+ ::= { sfcsCnxStatsTable 1 }
+
+SfcsCnxStatsEntry ::=
+ SEQUENCE {
+ sfcsCnxStatsCrossConnectIndex INTEGER,
+ sfcsCnxStatsCrossConnectLowIfIndex INTEGER,
+ sfcsCnxStatsCrossConnectLowVpi INTEGER,
+ sfcsCnxStatsCrossConnectLowVci INTEGER,
+ sfcsCnxStatsCrossConnectHighIfIndex INTEGER,
+ sfcsCnxStatsCrossConnectHighVpi INTEGER,
+ sfcsCnxStatsCrossConnectHighVci INTEGER,
+ sfcsCnxStatsLoToHiHTxCells OCTET STRING,
+ sfcsCnxStatsLoToHiDroppedCells OCTET STRING,
+ sfcsCnxStatsLoToHiTaggedCells OCTET STRING,
+ sfcsCnxStatsHiToLoHTxCells OCTET STRING,
+ sfcsCnxStatsHiToLoDroppedCells OCTET STRING,
+ sfcsCnxStatsHiToLoTaggedCells OCTET STRING
+ }
+
+sfcsCnxStatsCrossConnectIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A unique value to identify this cross-connect."
+ ::= { sfcsCnxStatsEntry 1 }
+
+sfcsCnxStatsCrossConnectLowIfIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The value of this object is equal to the low
+ MIB II IfIndex value of the ATM interface port
+ for this cross-connect."
+ ::= { sfcsCnxStatsEntry 2 }
+
+sfcsCnxStatsCrossConnectLowVpi OBJECT-TYPE
+ SYNTAX INTEGER (0..4095)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The value of this object is equal to the low VPI
+ value at the ATM interface associated with the
+ cross-connect that is identified by
+ sfcsCnxStatsCrossConnectIndex."
+ ::= { sfcsCnxStatsEntry 3 }
+
+sfcsCnxStatsCrossConnectLowVci OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The value of this object is equal to the low VCI
+ value at the ATM interface associated with this
+ cross-connect that is identified by
+ sfcsCnxStatsCrossConnectIndex."
+ ::= { sfcsCnxStatsEntry 4 }
+
+sfcsCnxStatsCrossConnectHighIfIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The value of this object is equal to the high
+ MIB II IfIndex value of the ATM interface port
+ for this cross-connect."
+ ::= { sfcsCnxStatsEntry 5 }
+
+sfcsCnxStatsCrossConnectHighVpi OBJECT-TYPE
+ SYNTAX INTEGER (0..4095)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The value of this object is equal to the high VPI
+ value at the ATM interface associated with the
+ cross-connect that is identified by
+ sfcsCnxStatsCrossConnectIndex."
+ ::= { sfcsCnxStatsEntry 6 }
+
+sfcsCnxStatsCrossConnectHighVci OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The value of this object is equal to the high VCI
+ value at the ATM interface associated with this
+ cross-connect that is identified by
+ sfcsCnxStatsCrossConnectIndex."
+ ::= { sfcsCnxStatsEntry 7 }
+
+sfcsCnxStatsLoToHiHTxCells OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the transmitted cell count for this connection.
+ This entry specifies the count from the low port/vpi/vci
+ to the high port/vpi/vci"
+ ::= { sfcsCnxStatsEntry 8 }
+
+sfcsCnxStatsLoToHiDroppedCells OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the dropped cell count for this connection
+ instance. This entry specifies the count from the low
+ port/vpi/vci to the high port/vpi/vci."
+ ::= { sfcsCnxStatsEntry 9 }
+
+sfcsCnxStatsLoToHiTaggedCells OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the tagged cell count for this connection
+ instance. This entry specifies the count from the low
+ port/vpi/vci to the high port/vpi/vci."
+ ::= { sfcsCnxStatsEntry 10 }
+
+sfcsCnxStatsHiToLoHTxCells OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the transmitted cell count for this connection.
+ This entry specifies the count from the high port/vpi/vci
+ to the low port/vpi/vci"
+ ::= { sfcsCnxStatsEntry 11 }
+
+sfcsCnxStatsHiToLoDroppedCells OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the dropped cell count for this connection
+ instance. This entry specifies the count from the high
+ port/vpi/vci to the low port/vpi/vci."
+ ::= { sfcsCnxStatsEntry 12 }
+
+sfcsCnxStatsHiToLoTaggedCells OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the tagged cell count for this connection
+ instance. This entry specifies the count from the high
+ port/vpi/vci to the low port/vpi/vci."
+ ::= { sfcsCnxStatsEntry 13 }
+
+
+
+
+-- SFCS Switch Connection Error Table
+
+sfcsCnxErrorTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SfcsCnxErrorEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "This table contains the connection error information
+ supplied by the atmAPI mib."
+ ::= { sfcsConnectionError 1 }
+
+sfcsCnxErrorEntry OBJECT-TYPE
+ SYNTAX SfcsCnxErrorEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of VCC connection request failures. This table
+ is indexed the same way as the atmVcCrossConnectTable
+ in the AToM mib."
+ INDEX { atmVcCrossConnectIndex, atmVcCrossConnectLowIfIndex, atmVcCrossConnectLowVpi, atmVcCrossConnectLowVci, atmVcCrossConnectHighIfIndex, atmVcCrossConnectHighVpi, atmVcCrossConnectHighVci }
+-- AUGMENTS { sfcsCnxCfgEntry }
+ ::= { sfcsCnxErrorTable 1 }
+
+
+SfcsCnxErrorEntry ::=
+ SEQUENCE {
+ sfcsCnxErrorCode OCTET STRING,
+ sfcsCnxErrorTimeStamp TimeTicks,
+ sfcsCnxErrorRowStatus INTEGER
+ }
+
+sfcsCnxErrorCode OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies the error reason for failure of the
+ connection setup.
+
+
+ 01 fatal_error
+ 02 moe_table_out_of_range
+ 03 moe_mem_not_allocated
+ 04 mem_fetch_double_reqst
+ 05 lo_port_invalid
+ 06 lo_port_locked
+ 07 lo_vpi_invalid
+ 08 lo_vci_invalid
+ 09 hi_port_invalid
+ 10 hi_port_locked
+ 11 hi_vpi_invalid
+ 12 hi_vci_invalid
+ 13 trfc_desc_l2h_invalid
+ 14 trfc_desc_h2l_invalid
+ 15 ccid_invalid
+ 16 ccid_not_assigned
+ 17 atm_api_type_invalid
+ 18 atm_api_verb_invalid
+ 19 pt_to_pt_over_write_reqst
+ 20 pt_reqst_over_mpt_conn
+ 21 mask_table_full
+ 22 duplicate_request
+ 23 moe_table_out_of_memory
+ 24 vpi0_non_term_reqst
+ 25 hardware_out_of_heap
+ 26 tx_conn_table_out_of_mem
+ 27 tx_conn_table_time_out
+ 28 ctm_communication_error
+ 29 connection_table_out_of_sync
+ 30 invalid_connection_entry
+ 31 ctm_resource_alloc_error
+ 32 front_panel_bandwidth_alloc_error
+ 33 ccid_in_use"
+
+ ::= { sfcsCnxErrorEntry 1 }
+
+sfcsCnxErrorTimeStamp OBJECT-TYPE
+ SYNTAX TimeTicks
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the value of the sysUpTime when this
+ connection request failed. We will support this
+ field only if the element management uses this
+ table."
+ ::= { sfcsCnxErrorEntry 2 }
+
+
+sfcsCnxErrorRowStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ other (1),
+ inactive (2),
+ active (3),
+ delete (4)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The administrative control of this entry. The owner
+ could delete this entry after reading it, to prevent
+ this table from growing too big.
+ other (1)
+ inactive (2)
+ active (3)
+ delete (4)"
+ ::= { sfcsCnxErrorEntry 3 }
+
+
+
+
+-- The SFCS connection API Group
+
+sfcsCnxAPIEntry OBJECT-TYPE
+ SYNTAX INTEGER (1)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "
+ The connection API leaf provides a method for contool for creating
+ PVCs. This always returns a value of 0.
+ "
+
+ ::= { sfcsConnectionAPI 1 }
+
+
+
+
+-- The SFCS Switch CTM Group
+
+sfcsCTMInterfaceConfigTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SfcsCTMInterfaceConfigEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "This table contains the configuration information of each
+ configured SHEMP interface. If SFCS is not configured
+ on a port, than an entry will not exist."
+ ::= { sfcsCTMInterfaceConfig 1 }
+
+sfcsCTMInterfaceConfigEntry OBJECT-TYPE
+ SYNTAX SfcsCTMInterfaceConfigEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Each entry specifies the SFCS configuration for the SFCS
+ switch interface for which the entry exists."
+ INDEX { sfcsCTMInterfaceConfigInterfaceIndex }
+ ::= { sfcsCTMInterfaceConfigTable 1 }
+
+SfcsCTMInterfaceConfigEntry ::=
+ SEQUENCE {
+ sfcsCTMInterfaceConfigInterfaceIndex INTEGER,
+ sfcsCTMInterfaceConfigType INTEGER,
+ sfcsCTMInterfacePeakBufferUseage INTEGER,
+ sfcsCTMInterfaceConfigNumberOfQueues INTEGER,
+ sfcsCTMInterfaceConfigSigStackID INTEGER,
+ sfcsCTMInterfaceConfigClocking INTEGER,
+ sfcsCTMInterfaceConfigNextVPI INTEGER,
+ sfcsCTMInterfaceConfigNextVCI INTEGER
+ }
+
+sfcsCTMInterfaceConfigInterfaceIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index which specifies which interface we are
+ dealing with."
+ ::= { sfcsCTMInterfaceConfigEntry 1 }
+
+sfcsCTMInterfaceConfigType OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1),
+ access-port(2),
+ network-port(3),
+ host-mgmt-port(4),
+ host-ctl-port(5)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Sets the type of interface access attribute for the SFCS
+ interfaces. Access ports allow single user or shared
+ access and perform statisics and control; network ports
+ are equivalent to trunk ports with no access control;
+ host management port indicates the (virtual) port to which
+ the (internal) management agent is attached; host control
+ port indicates the port to redirect non-management packets.
+ other(1),
+ access-port(2),
+ network-port(3),
+ host-mgmt-port(4),
+ host-ctl-port(5)
+
+"
+ ::= { sfcsCTMInterfaceConfigEntry 2 }
+
+sfcsCTMInterfacePeakBufferUseage OBJECT-TYPE
+ SYNTAX INTEGER (0..100)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the number of cells in transmit buffer memory."
+ ::= { sfcsCTMInterfaceConfigEntry 3 }
+
+sfcsCTMInterfaceConfigNumberOfQueues OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the number of priority queues configured on this
+ interface."
+ ::= { sfcsCTMInterfaceConfigEntry 4 }
+
+sfcsCTMInterfaceConfigSigStackID OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the user signalling stack ID for this interface."
+ ::= { sfcsCTMInterfaceConfigEntry 5 }
+
+sfcsCTMInterfaceConfigClocking OBJECT-TYPE
+ SYNTAX INTEGER {
+ generated-transmit-clock(1),
+ channel-recovered-clock(2),
+ system-master-clock(3),
+ not-supported(4)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The anim clocking source.
+ one - use the generated-transmit-clock
+ two - use the channel-recovered-clock
+ three - use the system-master-clock
+ four - option not supported by this interface"
+ ::= { sfcsCTMInterfaceConfigEntry 6 }
+
+sfcsCTMInterfaceConfigNextVPI OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the next vpi for this interface."
+ ::= { sfcsCTMInterfaceConfigEntry 7 }
+
+sfcsCTMInterfaceConfigNextVCI OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the next vci for this interface."
+ ::= { sfcsCTMInterfaceConfigEntry 8 }
+
+
+-- SFCS SHEMP Interface Statistics Tables
+-- This table contains the objects that specify the packet and byte counters
+-- for each configured SFCS switching interface.
+
+
+sfcsCTMInterfaceStatsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SfcsCTMInterfaceStatsEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "This table contains the cell counts for each
+ SFCS switch interface."
+ ::= { sfcsCTMInterfaceStatistics 1 }
+
+sfcsCTMInterfaceStatsEntry OBJECT-TYPE
+ SYNTAX SfcsCTMInterfaceStatsEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies the SFCS cell counts for the SFCS
+ interface for which this entry exists."
+ INDEX { sfcsCTMInterfaceStatsInterfaceIndex }
+ ::= { sfcsCTMInterfaceStatsTable 1 }
+
+SfcsCTMInterfaceStatsEntry ::=
+ SEQUENCE {
+ sfcsCTMInterfaceStatsInterfaceIndex INTEGER,
+ sfcsCTMInterfaceStatsRxErrors OCTET STRING,
+ sfcsCTMInterfaceStatsVPILookupInvalidErrors OCTET STRING,
+ sfcsCTMInterfaceStatsRxCnxLookupInvalidErrors OCTET STRING,
+ sfcsCTMInterfaceStatsRxCellCnt OCTET STRING,
+ sfcsCTMInterfaceStatsTxCellCnt OCTET STRING,
+ sfcsCTMInterfaceStatsOverflowDropCellCnt OCTET STRING
+ }
+
+sfcsCTMInterfaceStatsInterfaceIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index which specifies which interface we are
+ dealing with."
+ ::= { sfcsCTMInterfaceStatsEntry 1 }
+
+sfcsCTMInterfaceStatsRxErrors OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the number of receive path lookup
+ invalid and out of range errors."
+ ::= { sfcsCTMInterfaceStatsEntry 2 }
+
+sfcsCTMInterfaceStatsVPILookupInvalidErrors OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the number of VPI lookup invalid and out of
+ range errors."
+ ::= { sfcsCTMInterfaceStatsEntry 3 }
+
+sfcsCTMInterfaceStatsRxCnxLookupInvalidErrors OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the number of receive connection lookup
+ invalid errors."
+ ::= { sfcsCTMInterfaceStatsEntry 4 }
+
+sfcsCTMInterfaceStatsRxCellCnt OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the number of receive cells on
+ this interface."
+ ::= { sfcsCTMInterfaceStatsEntry 7 }
+
+
+sfcsCTMInterfaceStatsTxCellCnt OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the number of transmit cells
+ on this interface."
+ ::= { sfcsCTMInterfaceStatsEntry 8 }
+
+
+sfcsCTMInterfaceStatsOverflowDropCellCnt OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the number of cells that were
+ dropped due to queue overflows."
+ ::= { sfcsCTMInterfaceStatsEntry 9 }
+
+
+-- SFCS SHEMP Queue Group
+-- This group contains the managed objects for maintaining SFCS Shemp Queues.
+
+-- SFCS Shemp Queue Configuration Table
+
+sfcsCTMQueueConfigTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SfcsCTMQueueConfigEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "This table contains the configuration information for
+ all queues on the SFCS."
+ ::= { sfcsCTMQueueConfig 1 }
+
+sfcsCTMQueueConfigEntry OBJECT-TYPE
+ SYNTAX SfcsCTMQueueConfigEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Each entry specifies the queue information for the
+ SFCS switch for which the entry exists."
+ INDEX { sfcsCTMQueueConfigInterfaceIndex, sfcsQueueConfigQueueIndex }
+ ::= { sfcsCTMQueueConfigTable 1 }
+
+SfcsCTMQueueConfigEntry ::=
+ SEQUENCE {
+ sfcsCTMQueueConfigInterfaceIndex INTEGER,
+ sfcsCTMQueueConfigQueueIndex INTEGER,
+ sfcsCTMQueueConfigQueueSize INTEGER,
+ sfcsCTMQueueConfigQueueBandwidth INTEGER,
+ sfcsCTMQueueConfigClpDropThreshold INTEGER,
+ sfcsCTMQueueConfigCongestionThreshold INTEGER,
+ sfcsCTMQueueConfigEFCILowThreshold INTEGER,
+ sfcsCTMQueueConfigRMThreshold INTEGER
+ }
+
+sfcsCTMQueueConfigInterfaceIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index which specifies which interface we are
+ dealing with."
+ ::= { sfcsCTMQueueConfigEntry 1 }
+
+sfcsCTMQueueConfigQueueIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index which specifies which transmit queue we
+ are dealing with."
+ ::= { sfcsCTMQueueConfigEntry 2 }
+
+sfcsCTMQueueConfigQueueSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the size of the transmit queue for this
+ queue instance."
+ ::= { sfcsCTMQueueConfigEntry 3 }
+
+sfcsCTMQueueConfigQueueBandwidth OBJECT-TYPE
+ SYNTAX INTEGER (0..100)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the percentage of this interface's bandwidth
+ utilized by this particular queue."
+ ::= { sfcsCTMQueueConfigEntry 4 }
+
+sfcsCTMQueueConfigClpDropThreshold OBJECT-TYPE
+ SYNTAX INTEGER (0..100)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the queue level to start dropping CLP=1
+ cells for this queue. This level is expressed as
+ the percentage of this queue's size."
+ ::= { sfcsCTMQueueConfigEntry 5 }
+
+sfcsCTMQueueConfigCongestionThreshold OBJECT-TYPE
+ SYNTAX INTEGER (0..100)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the level to consider this queue congested.
+ This level is expressed as the percentage of this
+ queue's size."
+ ::= { sfcsCTMQueueConfigEntry 6 }
+
+sfcsCTMQueueConfigEFCILowThreshold OBJECT-TYPE
+ SYNTAX INTEGER (0..100)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the lower threshold used for EFCI for
+ this queue instance. This level is expressed as
+ the percentage of this queue's size."
+ ::= { sfcsCTMQueueConfigEntry 7 }
+
+sfcsCTMQueueConfigRMThreshold OBJECT-TYPE
+ SYNTAX INTEGER (0..100)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the remote management queue threshold expressed
+ as a percentage of the queue's size. When this level is
+ hit, a management message is sent to the sender notifying it
+ to slow down."
+ ::= { sfcsCTMQueueConfigEntry 8 }
+
+
+
+
+-- SFCS Shemp Queue Stats Table
+
+sfcsCTMQueueStatsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SfcsCTMQueueStatsEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "This table contains the statistics information for all
+ queues on the SFCS."
+ ::= { sfcsCTMQueueStatistics 1 }
+
+sfcsCTMQueueStatsEntry OBJECT-TYPE
+ SYNTAX SfcsCTMQueueStatsEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Each entry specifies the queue information for the
+ SFCS switch for which the entry exists."
+ INDEX { sfcsCTMQueueStatsInterfaceIndex, sfcsQueueStatsQueue }
+ ::= { sfcsCTMQueueStatsTable 1 }
+
+SfcsCTMQueueStatsEntry ::=
+ SEQUENCE {
+ sfcsCTMQueueStatsInterfaceIndex INTEGER,
+ sfcsCTMQueueStatsQueue INTEGER,
+ sfcsCTMQueueStatsTxClpCellsDiscarded OCTET STRING,
+ sfcsCTMQueueStatsTxCellsDropped OCTET STRING,
+ sfcsCTMQueueStatsQueuePeakLevel INTEGER,
+ sfcsCTMQueueStatsTxCellCnt OCTET STRING
+ }
+
+sfcsCTMQueueStatsInterfaceIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index which specifies which interface we are
+ dealing with."
+ ::= { sfcsCTMQueueStatsEntry 1 }
+
+sfcsCTMQueueStatsQueue OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index which specifies which queue we are
+ dealing with."
+ ::= { sfcsCTMQueueStatsEntry 2 }
+
+sfcsCTMQueueStatsTxClpCellsDiscarded OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the number of cells with CLP=1 that were
+ discarded for this queue instance."
+ ::= { sfcsCTMQueueStatsEntry 3 }
+
+sfcsCTMQueueStatsTxCellsDropped OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the number of cells that overflowed the
+ buffer for this queue instance."
+ ::= { sfcsCTMQueueStatsEntry 4 }
+
+sfcsCTMQueueStatsQueuePeakLevel OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the peak level since last read for this
+ queue instance."
+ ::= { sfcsCTMQueueStatsEntry 5 }
+
+sfcsCTMQueueStatsTxCellCnt OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the transmit cell count on a per queue basis.
+ A value of zero indicates not available"
+ ::= { sfcsCTMQueueStatsEntry 6 }
+
+
+
+-- The SFCS Switch Host Group
+
+-- The SFCS Switch UniMux Group
+
+-- SFCS Switch Bandwidth Management Group
+-- This group contains the managed objects and functions used to setup and
+-- configure the SFCS Bandwidth Manager. This group contains four sub-groups
+-- Nim Tables, Port Tables, Bandwidth Pool elements and Buffer Tables.
+
+-- SFCS ANIM Bandwidth Management Nim Table
+-- This table contains contains information about the administration status of the Nim.
+-- %%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
+-- ### Nim Information
+
+sfcsBwNimsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SfcsBwNimsEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "This table contains the Nim Oid and the Nim Administrative Status
+ reading functions."
+ ::= { sfcsBwNims 1 }
+
+sfcsBwNimsEntry OBJECT-TYPE
+ SYNTAX SfcsBwNimsEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Each entry contains a Nim Oid and the Nim Administrative Status."
+ INDEX { sfcsBwNimsIndex }
+ ::= { sfcsBwNimsTable 1 }
+
+SfcsBwNimsEntry ::=
+ SEQUENCE {
+ sfcsBwNimsIndex INTEGER,
+ sfcsBwNimsAdminStatus INTEGER,
+ sfcsBWNimsBuffCount INTEGER,
+ sfcsBWNimsPortCount INTEGER,
+ sfcsBWNimsPrioCount INTEGER
+ }
+
+-- ### Nim Defs
+sfcsBwNimsIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This index specifies which NIM we are dealing
+ with. This reference is in the same format as MIB II's
+ Interface index."
+ ::= { sfcsBwNimsEntry 1 }
+
+sfcsBwNimsAdminStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the administrative status of this Nim.
+ 10 - Active
+ 20 - Inactive "
+ ::= { sfcsBwNimsEntry 2 }
+
+sfcsBWNimsBuffCount OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of transmit buffers for this NIM"
+ ::= { sfcsBwNimsEntry 3 }
+
+sfcsBWNimsPortCount OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of ports for this NIM"
+ ::= { sfcsBwNimsEntry 4 }
+
+sfcsBWNimsPrioCount OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of priority queues for this NIM"
+ ::= { sfcsBwNimsEntry 5 }
+
+-- %%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
+-- ### Port Information
+
+sfcsBwPortsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SfcsBwPortsEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "This table contains the Port Oid, Port Administrative Status and
+ the forward/reverse physical bandwidth reading functions."
+ ::= { sfcsBwPorts 1 }
+
+sfcsBwPortsEntry OBJECT-TYPE
+ SYNTAX SfcsBwPortsEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Each entry contains the Port Oid, Port Administrative Status and
+ the forward/reverse physical bandwidth."
+ INDEX { sfcsBwPortsIndex }
+ ::= { sfcsBwPortsTable 1 }
+
+SfcsBwPortsEntry ::=
+ SEQUENCE
+ {
+ sfcsBwPortsIndex INTEGER,
+ sfcsBwPortsAdminStatus INTEGER,
+ sfcsBwPortsPhysBwFwd INTEGER,
+ sfcsBwPortsPhysBwRev INTEGER,
+ sfcsBwPortsZone INTEGER,
+ sfcsBwPortsMetric INTEGER
+ }
+
+-- #Ports Defs
+sfcsBwPortsIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This index specifies which Port we are dealing
+ with. This reference is in the same format as MIB II's
+ Interface index."
+ ::= { sfcsBwPortsEntry 1 }
+
+sfcsBwPortsAdminStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the administrative status of this Port.
+ 10 - Active
+ 20 - Inactive "
+ ::= { sfcsBwPortsEntry 2 }
+
+sfcsBwPortsPhysBwFwd OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This is the forward physical bandwidth of the port in cells/sec."
+ ::= { sfcsBwPortsEntry 3 }
+
+sfcsBwPortsPhysBwRev OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This is the reverse physical bandwidth of the port in cells/sec."
+ ::= { sfcsBwPortsEntry 4 }
+
+sfcsBwPortsZone OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The range of the current bw operational point for this port. If a value has never been set the value will be -1."
+ ::= { sfcsBwPortsEntry 5 }
+
+sfcsBwPortsMetric OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The current bw operational point for this port. If a value has never been set the value will be -1."
+ ::= { sfcsBwPortsEntry 6 }
+
+
+-- %%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
+-- ### Bandwidth Pool Limits Information
+
+sfcsBwPortPoolLimitsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SfcsBwPortPoolLimitsEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "This table contains "
+ ::= { sfcsBwPortPools 1 }
+
+sfcsBwPortPoolLimitsEntry OBJECT-TYPE
+ SYNTAX SfcsBwPortPoolLimitsEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Each entry contains "
+ INDEX { sfcsBwPortPoolLimitsIndex, sfcsBwPortPoolLimitsPoolIndex }
+ ::= { sfcsBwPortPoolLimitsTable 1 }
+
+SfcsBwPortPoolLimitsEntry ::=
+ SEQUENCE
+ {
+ sfcsBwPortPoolLimitsIndex INTEGER,
+ sfcsBwPortPoolLimitsPoolIndex INTEGER,
+ sfcsBwPortPoolLimitsMaxAllocBwFwd INTEGER,
+ sfcsBwPortPoolLimitsMaxAllocBwRev INTEGER,
+ sfcsBwPortPoolLimitsBwAllocStrat INTEGER,
+ sfcsBwPortPoolLimitsBwConstant INTEGER,
+ sfcsBwPortPoolLimitsCBRLimitFwd INTEGER,
+ sfcsBwPortPoolLimitsCBRLimitRev INTEGER,
+ sfcsBwPortPoolLimitsABRLimitFwd INTEGER,
+ sfcsBwPortPoolLimitsABRLimitRev INTEGER,
+ sfcsBwPortPoolLimitsVBRLimitFwd INTEGER,
+ sfcsBwPortPoolLimitsVBRLimitRev INTEGER,
+ sfcsBwPortPoolLimitsUBRLimitFwd INTEGER,
+ sfcsBwPortPoolLimitsUBRLimitRev INTEGER,
+ sfcsBwPortPoolLimitsUBRConnLimitFwd INTEGER,
+ sfcsBwPortPoolLimitsUBRConnLimitRev INTEGER
+ }
+
+-- # Limit Definitions
+sfcsBwPortPoolLimitsIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This index specifies which Port we are dealing
+ with. This reference is in the same format as MIB II's
+ Interface index."
+ ::= { sfcsBwPortPoolLimitsEntry 1 }
+
+sfcsBwPortPoolLimitsPoolIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This index specifies which Pool within Port we are dealing
+ with. This reference is in the same format as MIB II's
+ Interface index."
+ ::= { sfcsBwPortPoolLimitsEntry 2 }
+
+sfcsBwPortPoolLimitsMaxAllocBwFwd OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " Upper Limit for BW to be allocated forward direction. It is defaulted to
+ the physical BW and is set by administrative action. Can't be set to
+ a value greater than physical BW"
+ ::= { sfcsBwPortPoolLimitsEntry 3 }
+
+sfcsBwPortPoolLimitsMaxAllocBwRev OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " Upper Limit for BW to be allocated reverse direction. It is defaulted to
+ the physical BW and is set by administrative action. Can't be set to
+ a value greater than physical BW"
+
+ ::= { sfcsBwPortPoolLimitsEntry 4 }
+
+sfcsBwPortPoolLimitsBwAllocStrat OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " Determines which of 3 sets of formulas will be used for computing
+ the amount of variable bandwidth to be allocated.
+ Conservative allocates the full amount of variable bandwidth,
+ Moderate allocates approximately half of the variable bandwidth,
+ Liberal supports very aggressive allocation and should only be
+ used with caution. Conservative is the default."
+ ::= { sfcsBwPortPoolLimitsEntry 5 }
+
+sfcsBwPortPoolLimitsBwConstant OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " A ratio used in formulas for computing the amount of variable
+ bandwidth to be allocated. Valid values are 1-255 which is the
+ numerator of a fraction whose fixed denominator is 256. Thus
+ the value 255 is really 255/256 the most conservative value;
+ the value 1 is really 1/256 the most liberal value; the value
+ 128 is really 128/256 or 50%. The default is 50%."
+ ::= { sfcsBwPortPoolLimitsEntry 6 }
+
+sfcsBwPortPoolLimitsCBRLimitFwd OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " A ratio used in allocating the allocatable bandwidth among the
+ various Service classes. This value is the amount of the overall
+ allocatable bw that can be allocated to CBR. The values are 1-255.
+ For a more detailed description of value useage see
+ sfcsBwPortPoolLimitsBwConstant. Total of all service classes for a
+ given direction should not exceed 256. (If it has never been set,
+ the value will be -1.)"
+ ::= { sfcsBwPortPoolLimitsEntry 7 }
+
+sfcsBwPortPoolLimitsCBRLimitRev OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " A ratio used in allocating the allocatable bandwidth among the
+ various Service classes. This value is the amount of the overall
+ allocatable bw that can be allocated to CBR. The values are 1-255.
+ For a more detailed description of value useage see
+ sfcsBwPortPoolLimitsBwConstant. Total of all service classes for a
+ given direction should not exceed 256. (If it has never been set,
+ the value will be -1.)"
+ ::= { sfcsBwPortPoolLimitsEntry 8 }
+
+sfcsBwPortPoolLimitsABRLimitFwd OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " A ratio used in allocating the allocatable bandwidth among the
+ various Service classes. This value is the amount of the overall
+ allocatable bw that can be allocated to ABR. The values are 1-255.
+ For a more detailed description of value useage see
+ sfcsBwPortPoolLimitsBwConstant. Total of all service classes for a
+ given direction should not exceed 256. (If it has never been set,
+ the value will be -1.)"
+ ::= { sfcsBwPortPoolLimitsEntry 9 }
+
+sfcsBwPortPoolLimitsABRLimitRev OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " A ratio used in allocating the allocatable bandwidth among the
+ various Service classes. This value is the amount of the overall
+ allocatable bw that can be allocated to ABR. The values are 1-255.
+ For a more detailed description of value useage see
+ sfcsBwPortPoolLimitsBwConstant. Total of all service classes for a
+ given direction should not exceed 256. (If it has never been set,
+ the value will be -1.)"
+ ::= { sfcsBwPortPoolLimitsEntry 10 }
+
+sfcsBwPortPoolLimitsVBRLimitFwd OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " A ratio used in allocating the allocatable bandwidth among the
+ various Service classes. This value is the amount of the overall
+ allocatable bw that can be allocated to VBR. The values are 1-255.
+ For a more detailed description of value useage see
+ sfcsBwPortPoolLimitsBwConstant. Total of all service classes for a
+ given direction should not exceed 256. (If it has never been set,
+ the value will be -1.)
+ WARNING - Setting this limit to an arbitrarily low value may
+ cause the switch to become inoperable as an SVC switch. PNNI
+ establishes VBR connections for switch to switch communications.
+ If an arbitrarily low limit is established, it may preclude
+ PNNI inter-switch operability."
+ ::= { sfcsBwPortPoolLimitsEntry 11 }
+
+sfcsBwPortPoolLimitsVBRLimitRev OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " A ratio used in allocating the allocatable bandwidth among the
+ various Service classes. This value is the amount of the overall
+ allocatable bw that can be allocated to VBR. The values are 1-255.
+ For a more detailed description of value useage see
+ sfcsBwPortPoolLimitsBwConstant. Total of all service classes for a
+ given direction should not exceed 256. (If it has never been set,
+ the value will be -1.)
+ WARNING - Setting this limit to an arbitrarily low value may
+ cause the switch to become inoperable as an SVC switch. PNNI
+ establishes VBR connections for switch to switch communications.
+ If an arbitrarily low limit is established, it may preclude
+ PNNI inter-switch operability."
+ ::= { sfcsBwPortPoolLimitsEntry 12 }
+
+sfcsBwPortPoolLimitsUBRLimitFwd OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " A ratio used in allocating the allocatable bandwidth among the
+ various Service classes. This value is the amount of the overall
+ allocatable bw that can be allocated to UBR. The values are 1-255.
+ For a more detailed description of value useage see
+ sfcsBwPortPoolLimitsBwConstant. Total of all service classes for a
+ given direction should not exceed 256. (If it has never been set,
+ the value will be -1.)
+ WARNING - Setting this limit to an arbitrarily low value may
+ cause the switch to become inoperable as an SVC switch. Many
+ internal management functions use UBR connections to establish
+ connections with neighboring switches for keep alive and
+ discovery functions.
+ If an arbitrarily low limit is established, it may preclude
+ SVC inter-switch operability."
+ ::= { sfcsBwPortPoolLimitsEntry 13 }
+
+sfcsBwPortPoolLimitsUBRLimitRev OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " A ratio used in allocating the allocatable bandwidth among the
+ various Service classes. This value is the amount of the overall
+ allocatable bw that can be allocated to UBR. The values are 1-255.
+ For a more detailed description of value useage see
+ sfcsBwPortPoolLimitsBwConstant. Total of all service classes for a
+ given direction should not exceed 256. (If it has never been set,
+ the value will be -1.)
+ WARNING - Setting this limit to an arbitrarily low value may
+ cause the switch to become inoperable as an SVC switch. Many
+ internal management functions use UBR connections to establish
+ connections with neighboring switches for keep alive and
+ discovery functions.
+ If an arbitrarily low limit is established, it may preclude
+ SVC inter-switch operability."
+ ::= { sfcsBwPortPoolLimitsEntry 14 }
+
+sfcsBwPortPoolLimitsUBRConnLimitFwd OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " A Limit to the number of UBR connections which can be established
+ through this port. The limit applies to both user connections and
+ management connections. The default is no limit. (If it has never
+ been set, the value will be -1.)"
+ ::= { sfcsBwPortPoolLimitsEntry 15 }
+
+sfcsBwPortPoolLimitsUBRConnLimitRev OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " A Limit to the number of UBR connections which can be established
+ through this port. The limit applies to both user connections and
+ management connections. The default is no limit. (If it has never
+ been set, the value will be -1.)"
+ ::= { sfcsBwPortPoolLimitsEntry 16 }
+
+-- %%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
+-- ### Bandwidth Pool Statistical Information
+
+sfcsBwPortPoolStatTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SfcsBwPortPoolStatEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "This table contains "
+ ::= { sfcsBwPortPools 2 }
+
+sfcsBwPortPoolStatEntry OBJECT-TYPE
+ SYNTAX SfcsBwPortPoolStatEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Each entry contains "
+ INDEX { sfcsBwPortPoolStatsIndex, sfcsBwPortPoolStatsPoolIndex }
+ ::= { sfcsBwPortPoolStatTable 1 }
+
+SfcsBwPortPoolStatEntry ::=
+ SEQUENCE
+ {
+ sfcsBwPortPoolStatsIndex INTEGER,
+ sfcsBwPortPoolStatsPoolIndex INTEGER,
+ sfcsBwPortPoolStatConnCntFwd INTEGER,
+ sfcsBwPortPoolStatConnCntRev INTEGER,
+ sfcsBwPortPoolStatAllocBwFwd INTEGER,
+ sfcsBwPortPoolStatAllocBwRev INTEGER,
+ sfcsBwPortPoolStatAvailBwFwd INTEGER,
+ sfcsBwPortPoolStatAvailBwRev INTEGER,
+ sfcsBwPortPoolStatPeakBwFwd INTEGER,
+ sfcsBwPortPoolStatPeakBwRev INTEGER,
+ sfcsBwPortPoolStatRejConnFwd INTEGER,
+ sfcsBwPortPoolStatRejConnRev INTEGER,
+ sfcsBwPortPoolStatPrevAdverMAXCRFwd INTEGER,
+ sfcsBwPortPoolStatPrevAdverMAXCRRev INTEGER,
+ sfcsBwPortPoolStatPrevAdverAvailCRFwd INTEGER,
+ sfcsBwPortPoolStatPrevAdverAvailCRRev INTEGER,
+
+ sfcsBwPortPoolStatCBRConnCntFwd INTEGER,
+ sfcsBwPortPoolStatCBRConnCntRev INTEGER,
+ sfcsBwPortPoolStatCBRConnRejFwd INTEGER,
+ sfcsBwPortPoolStatCBRConnRejRev INTEGER,
+ sfcsBwPortPoolStatCBRAllocBwFwd INTEGER,
+ sfcsBwPortPoolStatCBRAllocBwRev INTEGER,
+ sfcsBwPortPoolStatCBRAggPCRFwd INTEGER,
+ sfcsBwPortPoolStatCBRAggPCRRev INTEGER,
+ sfcsBwPortPoolStatCBRPrevAdverMAXCTD INTEGER,
+ sfcsBwPortPoolStatCBRPrevAdverCDV INTEGER,
+
+ sfcsBwPortPoolStatABRConnCntFwd INTEGER,
+ sfcsBwPortPoolStatABRConnCntRev INTEGER,
+ sfcsBwPortPoolStatABRConnRejFwd INTEGER,
+ sfcsBwPortPoolStatABRConnRejRev INTEGER,
+ sfcsBwPortPoolStatABRAllocBwFwd INTEGER,
+ sfcsBwPortPoolStatABRAllocBwRev INTEGER,
+ sfcsBwPortPoolStatABRAggPCRFwd INTEGER,
+ sfcsBwPortPoolStatABRAggPCRRev INTEGER,
+ sfcsBwPortPoolStatABRPrevAdverMAXCTD INTEGER,
+ sfcsBwPortPoolStatABRPrevAdverCDV INTEGER,
+
+ sfcsBwPortPoolStatVBRConnCntFwd INTEGER,
+ sfcsBwPortPoolStatVBRConnCntRev INTEGER,
+ sfcsBwPortPoolStatVBRConnRejFwd INTEGER,
+ sfcsBwPortPoolStatVBRConnRejRev INTEGER,
+ sfcsBwPortPoolStatVBRAllocBwFwd INTEGER,
+ sfcsBwPortPoolStatVBRAllocBwRev INTEGER,
+ sfcsBwPortPoolStatVBRAggPCRFwd INTEGER,
+ sfcsBwPortPoolStatVBRAggPCRRev INTEGER,
+ sfcsBwPortPoolStatVBRPrevAdverMAXCTD INTEGER,
+ sfcsBwPortPoolStatVBRPrevAdverCDV INTEGER,
+
+ sfcsBwPortPoolStatUBRConnCntFwd INTEGER,
+ sfcsBwPortPoolStatUBRConnCntRev INTEGER,
+ sfcsBwPortPoolStatUBRConnRejFwd INTEGER,
+ sfcsBwPortPoolStatUBRConnRejRev INTEGER,
+ sfcsBwPortPoolStatUBRAllocBwFwd INTEGER,
+ sfcsBwPortPoolStatUBRAllocBwRev INTEGER,
+ sfcsBwPortPoolStatUBRAggPCRFwd INTEGER,
+ sfcsBwPortPoolStatUBRAggPCRRev INTEGER,
+ sfcsBwPortPoolStatUBRPrevAdverMAXCTD INTEGER,
+ sfcsBwPortPoolStatUBRPrevAdverCDV INTEGER
+}
+
+sfcsBwPortPoolStatsIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This index specifies which Port we are dealing
+ with. This reference is in the same format as MIB II's
+ Interface index."
+ ::= { sfcsBwPortPoolStatEntry 1 }
+
+sfcsBwPortPoolStatsPoolIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This index specifies which Pool within Port we are dealing
+ with. This reference is in the same format as MIB II's
+ Interface index."
+ ::= { sfcsBwPortPoolStatEntry 2 }
+
+sfcsBwPortPoolStatConnCntFwd OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ " The current total number of calls in the forward direction."
+ ::= { sfcsBwPortPoolStatEntry 3 }
+
+sfcsBwPortPoolStatConnCntRev OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ " The current total number of calls in the reverse direction."
+ ::= { sfcsBwPortPoolStatEntry 4 }
+
+sfcsBwPortPoolStatAllocBwFwd OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ " The current amount of allocated Bw in the forward direction."
+ ::= { sfcsBwPortPoolStatEntry 5 }
+
+sfcsBwPortPoolStatAllocBwRev OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ " The current amount of allocated Bw in the reverse direction."
+ ::= { sfcsBwPortPoolStatEntry 6 }
+
+sfcsBwPortPoolStatAvailBwFwd OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ " The current amount of available Bw in the forward direction."
+ ::= { sfcsBwPortPoolStatEntry 7 }
+
+sfcsBwPortPoolStatAvailBwRev OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ " The current amount of available Bw in the reverse direction."
+ ::= { sfcsBwPortPoolStatEntry 8 }
+
+sfcsBwPortPoolStatPeakBwFwd OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ " The peak amount of allocated Bw in the forward direction since the
+ port was initialized OR the switch was reset."
+ ::= { sfcsBwPortPoolStatEntry 9 }
+
+sfcsBwPortPoolStatPeakBwRev OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ " The peak amount of allocated Bw in the reverse direction since the
+ port was initialized OR the switch was reset."
+ ::= { sfcsBwPortPoolStatEntry 10 }
+
+sfcsBwPortPoolStatRejConnFwd OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ " The number of connections which were rejected because of
+ insufficient forward bandwidth since the port was initialized or
+ the switch was reset last."
+ ::= { sfcsBwPortPoolStatEntry 11 }
+
+sfcsBwPortPoolStatRejConnRev OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ " The number of connections which were rejected because of
+ insufficient reverse bandwidth since the port was initialized or
+ the switch was reset last."
+ ::= { sfcsBwPortPoolStatEntry 12 }
+
+sfcsBwPortPoolStatPrevAdverMAXCRFwd OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ " The amount of physical forward BW reported to PNNI in the latest
+ reporting period."
+ ::= { sfcsBwPortPoolStatEntry 13 }
+
+sfcsBwPortPoolStatPrevAdverMAXCRRev OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ " The amount of physical reverse BW reported to PNNI in the latest
+ reporting period."
+ ::= { sfcsBwPortPoolStatEntry 14 }
+
+sfcsBwPortPoolStatPrevAdverAvailCRFwd OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ " The amount of avail forward BW reported to PNNI in the latest
+ reporting period."
+ ::= { sfcsBwPortPoolStatEntry 15 }
+
+sfcsBwPortPoolStatPrevAdverAvailCRRev OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ " The amount of avail reverse BW reported to PNNI in the latest
+ reporting period."
+ ::= { sfcsBwPortPoolStatEntry 16 }
+
+-- # CBR Info
+
+sfcsBwPortPoolStatCBRConnCntFwd OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ " The number of currently established CBR connections for the forward
+ direction."
+ ::= { sfcsBwPortPoolStatEntry 17 }
+
+sfcsBwPortPoolStatCBRConnCntRev OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ " The number of currently established CBR connections for the reverse
+ direction."
+ ::= { sfcsBwPortPoolStatEntry 18 }
+
+sfcsBwPortPoolStatCBRConnRejFwd OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ " The number of CBR forward connections rejected since the port was
+ initialized or the switch was reset last."
+ ::= { sfcsBwPortPoolStatEntry 19 }
+
+sfcsBwPortPoolStatCBRConnRejRev OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ " The number of CBR reverse connections rejected since the port was
+ initialized or the switch was reset last."
+ ::= { sfcsBwPortPoolStatEntry 20 }
+
+sfcsBwPortPoolStatCBRAllocBwFwd OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ " The amount of forward allocated Bw that is CBR service class."
+ ::= { sfcsBwPortPoolStatEntry 21 }
+
+sfcsBwPortPoolStatCBRAllocBwRev OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ " The amount of reverse allocated Bw that is CBR service class."
+ ::= { sfcsBwPortPoolStatEntry 22 }
+
+sfcsBwPortPoolStatCBRAggPCRFwd OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ " The aggregated forward PCR for all established CBR connections."
+ ::= { sfcsBwPortPoolStatEntry 23 }
+
+sfcsBwPortPoolStatCBRAggPCRRev OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ " The aggregated reverse PCR for all established CBR connections."
+ ::= { sfcsBwPortPoolStatEntry 24 }
+
+sfcsBwPortPoolStatCBRPrevAdverMAXCTD OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ " The maxCTD for the forward direction reported to PNNI for the last
+ update period for CBR service class."
+ ::= { sfcsBwPortPoolStatEntry 25 }
+
+sfcsBwPortPoolStatCBRPrevAdverCDV OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ " The CDV for the forward direction reported to PNNI for the last
+ update period for CBR service class."
+ ::= { sfcsBwPortPoolStatEntry 26 }
+
+-- # ABR Information
+
+sfcsBwPortPoolStatABRConnCntFwd OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ " The number of currently established ABR connections for the forward
+ direction."
+ ::= { sfcsBwPortPoolStatEntry 27 }
+
+sfcsBwPortPoolStatABRConnCntRev OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ " The number of currently established ABR connections for the reverse
+ direction."
+ ::= { sfcsBwPortPoolStatEntry 28 }
+
+sfcsBwPortPoolStatABRConnRejFwd OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ " The number of ABR forward connections rejected since the port was
+ initialized or the switch was reset last."
+ ::= { sfcsBwPortPoolStatEntry 29 }
+
+sfcsBwPortPoolStatABRConnRejRev OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ " The number of ABR reverse connections rejected since the port was
+ initialized or the switch was reset last."
+ ::= { sfcsBwPortPoolStatEntry 30 }
+
+sfcsBwPortPoolStatABRAllocBwFwd OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ " The amount of forward allocated Bw that is ABR service class."
+ ::= { sfcsBwPortPoolStatEntry 31 }
+
+sfcsBwPortPoolStatABRAllocBwRev OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ " The amount of reverse allocated Bw that is ABR service class."
+ ::= { sfcsBwPortPoolStatEntry 32 }
+
+sfcsBwPortPoolStatABRAggPCRFwd OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ " The aggregated forward PCR for all established ABR connections."
+ ::= { sfcsBwPortPoolStatEntry 33 }
+
+sfcsBwPortPoolStatABRAggPCRRev OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ " The aggregated reverse PCR for all established ABR connections."
+ ::= { sfcsBwPortPoolStatEntry 34 }
+
+sfcsBwPortPoolStatABRPrevAdverMAXCTD OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ " The maxCTD for the forward direction reported to PNNI for the last
+ update period for ABR service class."
+ ::= { sfcsBwPortPoolStatEntry 35 }
+
+sfcsBwPortPoolStatABRPrevAdverCDV OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ " The CDV for the forward direction reported to PNNI for the last
+ update period for ABR service class."
+ ::= { sfcsBwPortPoolStatEntry 36 }
+
+-- # VBR Information
+
+sfcsBwPortPoolStatVBRConnCntFwd OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ " The number of currently established VBR connections for the forward
+ direction."
+ ::= { sfcsBwPortPoolStatEntry 37 }
+
+sfcsBwPortPoolStatVBRConnCntRev OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ " The number of currently established VBR connections for the reverse
+ direction."
+ ::= { sfcsBwPortPoolStatEntry 38 }
+
+sfcsBwPortPoolStatVBRConnRejFwd OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ " The number of VBR forward connections rejected since the port was
+ initialized or the switch was reset last."
+ ::= { sfcsBwPortPoolStatEntry 39 }
+
+sfcsBwPortPoolStatVBRConnRejRev OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ " The number of VBR reverse connections rejected since the port was
+ initialized or the switch was reset last."
+ ::= { sfcsBwPortPoolStatEntry 40 }
+
+sfcsBwPortPoolStatVBRAllocBwFwd OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ " The amount of forward allocated Bw that is VBR service class."
+ ::= { sfcsBwPortPoolStatEntry 41 }
+
+sfcsBwPortPoolStatVBRAllocBwRev OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ " The amount of reverse allocated Bw that is VBR service class."
+ ::= { sfcsBwPortPoolStatEntry 42 }
+
+sfcsBwPortPoolStatVBRAggPCRFwd OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ " The aggregated forward PCR for all established VBR connections."
+ ::= { sfcsBwPortPoolStatEntry 43 }
+
+sfcsBwPortPoolStatVBRAggPCRRev OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ " The aggregated reverse PCR for all established VBR connections."
+ ::= { sfcsBwPortPoolStatEntry 44 }
+
+sfcsBwPortPoolStatVBRPrevAdverMAXCTD OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ " The maxCTD for the forward direction reported to PNNI for the last
+ update period for VBR service class."
+ ::= { sfcsBwPortPoolStatEntry 45 }
+
+sfcsBwPortPoolStatVBRPrevAdverCDV OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ " The CDV for the forward direction reported to PNNI for the last
+ update period for VBR service class."
+ ::= { sfcsBwPortPoolStatEntry 46 }
+
+-- # UBR Information
+
+sfcsBwPortPoolStatUBRConnCntFwd OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ " The number of currently established UBR connections for the forward
+ direction."
+ ::= { sfcsBwPortPoolStatEntry 47 }
+
+sfcsBwPortPoolStatUBRConnCntRev OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ " The number of currently established UBR connections for the reverse
+ direction."
+ ::= { sfcsBwPortPoolStatEntry 48 }
+
+sfcsBwPortPoolStatUBRConnRejFwd OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ " The number of UBR forward connections rejected since the port was
+ initialized or the switch was reset last."
+ ::= { sfcsBwPortPoolStatEntry 49 }
+
+sfcsBwPortPoolStatUBRConnRejRev OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ " The number of UBR reverse connections rejected since the port was
+ initialized or the switch was reset last."
+ ::= { sfcsBwPortPoolStatEntry 50 }
+
+sfcsBwPortPoolStatUBRAllocBwFwd OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ " The amount of forward allocated Bw that is UBR service class."
+ ::= { sfcsBwPortPoolStatEntry 51 }
+
+sfcsBwPortPoolStatUBRAllocBwRev OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ " The amount of reverse allocated Bw that is UBR service class."
+ ::= { sfcsBwPortPoolStatEntry 52 }
+
+sfcsBwPortPoolStatUBRAggPCRFwd OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ " The aggregated forward PCR for all established UBR connections."
+ ::= { sfcsBwPortPoolStatEntry 53 }
+
+sfcsBwPortPoolStatUBRAggPCRRev OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ " The aggregated reverse PCR for all established UBR connections."
+ ::= { sfcsBwPortPoolStatEntry 54 }
+
+sfcsBwPortPoolStatUBRPrevAdverMAXCTD OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ " The maxCTD for the forward direction reported to PNNI for the last
+ update period for UBR service class."
+ ::= { sfcsBwPortPoolStatEntry 55 }
+
+sfcsBwPortPoolStatUBRPrevAdverCDV OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ " The CDV for the forward direction reported to PNNI for the last
+ update period for UBR service class."
+ ::= { sfcsBwPortPoolStatEntry 56 }
+
+-- %%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
+-- ### Bandwidth Pool Trap Management Information
+
+sfcsBwPortPoolTrapMgmtTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SfcsBwPortPoolTrapMgmtEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "This table contains "
+ ::= { sfcsBwPortPools 3 }
+
+sfcsBwPortPoolTrapMgmtEntry OBJECT-TYPE
+ SYNTAX SfcsBwPortPoolTrapMgmtEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Each entry contains "
+ INDEX { sfcsBwPortPoolTrapMgmtIndex, sfcsBwPortPoolTrapMgmtPoolIndex }
+ ::= { sfcsBwPortPoolTrapMgmtTable 1 }
+
+SfcsBwPortPoolTrapMgmtEntry ::=
+ SEQUENCE
+ {
+ sfcsBwPortPoolTrapMgmtIndex INTEGER,
+ sfcsBwPortPoolTrapMgmtPoolIndex INTEGER,
+ sfcsBwPortPoolTrapMgmtAllocBwTholdHiFwd INTEGER,
+ sfcsBwPortPoolTrapMgmtAllocBwTholdHiRev INTEGER,
+ sfcsBwPortPoolTrapMgmtAllocBwTholdLoFwd INTEGER,
+ sfcsBwPortPoolTrapMgmtAllocBwTholdLoRev INTEGER,
+ sfcsBwPortPoolTrapMgmtPeakBwTholdFwd INTEGER,
+ sfcsBwPortPoolTrapMgmtPeakBwTholdRev INTEGER,
+ sfcsBwPortPoolTrapMgmtHoldDownTime INTEGER,
+
+ sfcsBwPortPoolTrapMgmtCBRConnCntTholdHiFwd INTEGER,
+ sfcsBwPortPoolTrapMgmtCBRConnCntTholdHiRev INTEGER,
+ sfcsBwPortPoolTrapMgmtCBRConnCntTholdLoFwd INTEGER,
+ sfcsBwPortPoolTrapMgmtCBRConnCntTholdLoRev INTEGER,
+ sfcsBwPortPoolTrapMgmtCBRAllocBwTholdHiFwd INTEGER,
+ sfcsBwPortPoolTrapMgmtCBRAllocBwTholdHiRev INTEGER,
+ sfcsBwPortPoolTrapMgmtCBRAllocBwTholdLoFwd INTEGER,
+ sfcsBwPortPoolTrapMgmtCBRAllocBwTholdLoRev INTEGER,
+
+ sfcsBwPortPoolTrapMgmtABRConnCntTholdHiFwd INTEGER,
+ sfcsBwPortPoolTrapMgmtABRConnCntTholdHiRev INTEGER,
+ sfcsBwPortPoolTrapMgmtABRConnCntTholdLoFwd INTEGER,
+ sfcsBwPortPoolTrapMgmtABRConnCntTholdLoRev INTEGER,
+ sfcsBwPortPoolTrapMgmtABRAllocBwTholdHiFwd INTEGER,
+ sfcsBwPortPoolTrapMgmtABRAllocBwTholdHiRev INTEGER,
+ sfcsBwPortPoolTrapMgmtABRAllocBwTholdLoFwd INTEGER,
+ sfcsBwPortPoolTrapMgmtABRAllocBwTholdLoRev INTEGER,
+
+ sfcsBwPortPoolTrapMgmtVBRConnCntTholdHiFwd INTEGER,
+ sfcsBwPortPoolTrapMgmtVBRConnCntTholdHiRev INTEGER,
+ sfcsBwPortPoolTrapMgmtVBRConnCntTholdLoFwd INTEGER,
+ sfcsBwPortPoolTrapMgmtVBRConnCntTholdLoRev INTEGER,
+ sfcsBwPortPoolTrapMgmtVBRAllocBwTholdHiFwd INTEGER,
+ sfcsBwPortPoolTrapMgmtVBRAllocBwTholdHiRev INTEGER,
+ sfcsBwPortPoolTrapMgmtVBRAllocBwTholdLoFwd INTEGER,
+ sfcsBwPortPoolTrapMgmtVBRAllocBwTholdLoRev INTEGER,
+
+ sfcsBwPortPoolTrapMgmtUBRConnCntTholdHiFwd INTEGER,
+ sfcsBwPortPoolTrapMgmtUBRConnCntTholdHiRev INTEGER,
+ sfcsBwPortPoolTrapMgmtUBRConnCntTholdLoFwd INTEGER,
+ sfcsBwPortPoolTrapMgmtUBRConnCntTholdLoRev INTEGER,
+ sfcsBwPortPoolTrapMgmtUBRAllocBwTholdHiFwd INTEGER,
+ sfcsBwPortPoolTrapMgmtUBRAllocBwTholdHiRev INTEGER,
+ sfcsBwPortPoolTrapMgmtUBRAllocBwTholdLoFwd INTEGER,
+ sfcsBwPortPoolTrapMgmtUBRAllocBwTholdLoRev INTEGER,
+ sfcsBWPortPoolTrapMgmtBuffUpThold INTEGER,
+ sfcsBWPortPoolTrapMgmtBuffLoThold INTEGER,
+ sfcsBWPortPoolTrapMgmtConnRejThold INTEGER
+ }
+
+sfcsBwPortPoolTrapMgmtIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This index specifies which Port we are dealing
+ with. This reference is in the same format as MIB II's
+ Interface index."
+ ::= { sfcsBwPortPoolTrapMgmtEntry 1 }
+
+sfcsBwPortPoolTrapMgmtPoolIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This index specifies which Pool within Port we are dealing
+ with. This reference is in the same format as MIB II's
+ Interface index. (If it has never been set, the value will
+ be -1.)"
+ ::= { sfcsBwPortPoolTrapMgmtEntry 2 }
+
+sfcsBwPortPoolTrapMgmtAllocBwTholdHiFwd OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The upper threshold for the Alloc BW fwd trap. When an allocation
+ causes the currently allocated bw to exceed this value the trap
+ is generated. (If it has never been set, the value will
+ be -1.)"
+ ::= { sfcsBwPortPoolTrapMgmtEntry 3 }
+
+sfcsBwPortPoolTrapMgmtAllocBwTholdHiRev OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " The upper threshold for the Alloc BW rev trap. When an allocation
+ causes the currently allocated bw to exceed this value the trap
+ is generated. (If it has never been set, the value will
+ be -1.)"
+ ::= { sfcsBwPortPoolTrapMgmtEntry 4 }
+
+sfcsBwPortPoolTrapMgmtAllocBwTholdLoFwd OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " The lower threshold for the Alloc BW fwd trap. When an allocation
+ causes the currently allocated bw be below this value the trap
+ is generated. (If it has never been set, the value will
+ be -1.)"
+ ::= { sfcsBwPortPoolTrapMgmtEntry 5 }
+
+sfcsBwPortPoolTrapMgmtAllocBwTholdLoRev OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " The lower threshold for the Alloc BW rev trap. When an allocation
+ causes the currently allocated bw be below this value the trap
+ is generated. (If it has never been set, the value will
+ be -1.)"
+ ::= { sfcsBwPortPoolTrapMgmtEntry 6 }
+
+sfcsBwPortPoolTrapMgmtPeakBwTholdFwd OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The upper threshold for the Peak BW fwd trap. When an allocation
+ causes the allocated BW to exceed this value the trap is generated.
+ (If it has never been set, the value will be -1.)"
+ ::= { sfcsBwPortPoolTrapMgmtEntry 7 }
+
+sfcsBwPortPoolTrapMgmtPeakBwTholdRev OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The upper threshold for the Peak BW rev trap. When an allocation
+ causes the allocated BW to exceed this value the trap is generated.
+ (If it has never been set, the value will be -1.)"
+ ::= { sfcsBwPortPoolTrapMgmtEntry 8 }
+
+sfcsBwPortPoolTrapMgmtHoldDownTime OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " The time between traps of the same type. If a trap of a particular
+ type is generated for a particular port, another of that type for that
+ port will not be generated until the hold down time has expired.
+ (If it has never been set, the value will be -1.)"
+ ::= { sfcsBwPortPoolTrapMgmtEntry 9 }
+
+-- # CBR Information
+
+sfcsBwPortPoolTrapMgmtCBRConnCntTholdHiFwd OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " The upper threshold for the CBR connection count Fwd trap. When an
+ allocation causes the CBR connection count to exceed this value,
+ the trap is generated. (If it has never been set, the value will be -1.)"
+ ::= { sfcsBwPortPoolTrapMgmtEntry 10 }
+
+sfcsBwPortPoolTrapMgmtCBRConnCntTholdHiRev OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " The upper threshold for the CBR connection count Rev trap. When an
+ allocation causes the CBR connection count to exceed this value,
+ the trap is generated. (If it has never been set, the value will be -1.)"
+ ::= { sfcsBwPortPoolTrapMgmtEntry 11 }
+
+sfcsBwPortPoolTrapMgmtCBRConnCntTholdLoFwd OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " The lower threshold for the CBR connection count Fwd trap. When an
+ allocation causes the CBR connection count to fall below this value,
+ the trap is generated. (If it has never been set, the value will be -1.)"
+ ::= { sfcsBwPortPoolTrapMgmtEntry 12 }
+
+sfcsBwPortPoolTrapMgmtCBRConnCntTholdLoRev OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " The lower threshold for the CBR connection count Rev trap. When an
+ allocation causes the CBR connection count to fall below this value,
+ the trap is generated. (If it has never been set, the value will be -1.)"
+ ::= { sfcsBwPortPoolTrapMgmtEntry 13 }
+
+sfcsBwPortPoolTrapMgmtCBRAllocBwTholdHiFwd OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " The upper threshold for the CBR Allocated Bw Fwd trap. When an
+ allocation causes the CBR Allocated Bw to exceed this value,
+ the trap is generated. (If it has never been set, the value will be -1.)"
+ ::= { sfcsBwPortPoolTrapMgmtEntry 14 }
+
+sfcsBwPortPoolTrapMgmtCBRAllocBwTholdHiRev OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " The upper threshold for the CBR connection count Rev trap. When an
+ allocation causes the CBR connection count to exceed this value,
+ the trap is generated. (If it has never been set, the value will be -1.)"
+ ::= { sfcsBwPortPoolTrapMgmtEntry 15 }
+
+sfcsBwPortPoolTrapMgmtCBRAllocBwTholdLoFwd OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " The lower threshold for the CBR Allocated Bw Fwd trap. When an
+ allocation causes the CBR Allocated Bw to fall below this value,
+ the trap is generated. (If it has never been set, the value will be -1.)"
+ ::= { sfcsBwPortPoolTrapMgmtEntry 16 }
+
+sfcsBwPortPoolTrapMgmtCBRAllocBwTholdLoRev OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " The lower threshold for the CBR Allocated Bw Rev trap. When an
+ allocation causes the CBR Allocated Bw to fall below this value,
+ the trap is generated. (If it has never been set, the value will be -1.)"
+ ::= { sfcsBwPortPoolTrapMgmtEntry 17 }
+
+-- # ABR Information
+
+sfcsBwPortPoolTrapMgmtABRConnCntTholdHiFwd OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " The upper threshold for the ABR connection count Fwd trap. When an
+ allocation causes the ABR connection count to exceed this value,
+ the trap is generated. (If it has never been set, the value will be -1.)"
+ ::= { sfcsBwPortPoolTrapMgmtEntry 18 }
+
+sfcsBwPortPoolTrapMgmtABRConnCntTholdHiRev OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " The upper threshold for the ABR connection count Rev trap. When an
+ allocation causes the ABR connection count to exceed this value,
+ the trap is generated. (If it has never been set, the value will be -1.)"
+ ::= { sfcsBwPortPoolTrapMgmtEntry 19 }
+
+sfcsBwPortPoolTrapMgmtABRConnCntTholdLoFwd OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " The lower threshold for the ABR connection count Fwd trap. When an
+ allocation causes the ABR connection count to fall below this value,
+ the trap is generated. (If it has never been set, the value will be -1.)"
+ ::= { sfcsBwPortPoolTrapMgmtEntry 20 }
+
+sfcsBwPortPoolTrapMgmtABRConnCntTholdLoRev OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " The lower threshold for the ABR connection count Rev trap. When an
+ allocation causes the ABR connection count to fall below this value,
+ the trap is generated. (If it has never been set, the value will be -1.)"
+ ::= { sfcsBwPortPoolTrapMgmtEntry 21 }
+
+sfcsBwPortPoolTrapMgmtABRAllocBwTholdHiFwd OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " The upper threshold for the ABR Allocated Bw Fwd trap. When an
+ allocation causes the ABR Allocated Bw to exceed this value,
+ the trap is generated. (If it has never been set, the value will be -1.)"
+ ::= { sfcsBwPortPoolTrapMgmtEntry 22 }
+
+sfcsBwPortPoolTrapMgmtABRAllocBwTholdHiRev OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " The upper threshold for the ABR Allocated Bw Rev trap. When an
+ allocation causes the ABR Allocated Bw to exceed this value,
+ the trap is generated. (If it has never been set, the value will be -1.)"
+ ::= { sfcsBwPortPoolTrapMgmtEntry 23 }
+
+sfcsBwPortPoolTrapMgmtABRAllocBwTholdLoFwd OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " The lower threshold for the ABR Allocated Bw Fwd trap. When an
+ allocation causes the ABR Allocated Bw to fall below this value,
+ the trap is generated. (If it has never been set, the value will be -1.)"
+ ::= { sfcsBwPortPoolTrapMgmtEntry 24 }
+
+sfcsBwPortPoolTrapMgmtABRAllocBwTholdLoRev OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " The lower threshold for the ABR Allocated Bw Rev trap. When an
+ allocation causes the ABR Allocated Bw to fall below this value,
+ the trap is generated. (If it has never been set, the value will be -1.)"
+ ::= { sfcsBwPortPoolTrapMgmtEntry 25 }
+
+-- # VBR Information
+
+sfcsBwPortPoolTrapMgmtVBRConnCntTholdHiFwd OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " The upper threshold for the VBR connection count Fwd trap. When an
+ allocation causes the VBR connection count to exceed this value,
+ the trap is generated. (If it has never been set, the value will be -1.)"
+ ::= { sfcsBwPortPoolTrapMgmtEntry 26 }
+
+sfcsBwPortPoolTrapMgmtVBRConnCntTholdHiRev OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " The upper threshold for the VBR connection count Rev trap. When an
+ allocation causes the VBR connection count to exceed this value,
+ the trap is generated. (If it has never been set, the value will be -1.)"
+ ::= { sfcsBwPortPoolTrapMgmtEntry 27 }
+
+sfcsBwPortPoolTrapMgmtVBRConnCntTholdLoFwd OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " The lower threshold for the VBR connection count Fwd trap. When an
+ allocation causes the VBR connection count to fall below this value,
+ the trap is generated. (If it has never been set, the value will be -1.)"
+ ::= { sfcsBwPortPoolTrapMgmtEntry 28 }
+
+sfcsBwPortPoolTrapMgmtVBRConnCntTholdLoRev OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " The lower threshold for the VBR connection count Rev trap. When an
+ allocation causes the VBR connection count to fall below this value,
+ the trap is generated. (If it has never been set, the value will be -1.)"
+ ::= { sfcsBwPortPoolTrapMgmtEntry 29 }
+
+sfcsBwPortPoolTrapMgmtVBRAllocBwTholdHiFwd OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " The upper threshold for the VBR Allocated Bw Fwd trap. When an
+ allocation causes the VBR Allocated Bw to exceed this value,
+ the trap is generated. (If it has never been set, the value will be -1.)"
+ ::= { sfcsBwPortPoolTrapMgmtEntry 30 }
+
+sfcsBwPortPoolTrapMgmtVBRAllocBwTholdHiRev OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " The upper threshold for the VBR Allocated Bw Rev trap. When an
+ allocation causes the VBR Allocated Bw to exceed this value,
+ the trap is generated. (If it has never been set, the value will be -1.)"
+ ::= { sfcsBwPortPoolTrapMgmtEntry 31 }
+
+sfcsBwPortPoolTrapMgmtVBRAllocBwTholdLoFwd OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " The lower threshold for the VBR Allocated Bw Fwd trap. When an
+ allocation causes the VBR Allocated Bw to fall below this value,
+ the trap is generated. (If it has never been set, the value will be -1.)"
+ ::= { sfcsBwPortPoolTrapMgmtEntry 32 }
+
+sfcsBwPortPoolTrapMgmtVBRAllocBwTholdLoRev OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " The lower threshold for the VBR Allocated Bw Rev trap. When an
+ allocation causes the VBR Allocated Bw to fall below this value,
+ the trap is generated. (If it has never been set, the value will be -1.)"
+ ::= { sfcsBwPortPoolTrapMgmtEntry 33 }
+
+-- # UBR Information
+
+sfcsBwPortPoolTrapMgmtUBRConnCntTholdHiFwd OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " The upper threshold for the UBR connection count Fwd trap. When an
+ allocation causes the UBR connection count to exceed this value,
+ the trap is generated. (If it has never been set, the value will be -1.)"
+ ::= { sfcsBwPortPoolTrapMgmtEntry 34 }
+
+sfcsBwPortPoolTrapMgmtUBRConnCntTholdHiRev OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " The upper threshold for the UBR connection count Rev trap. When an
+ allocation causes the UBR connection count to exceed this value,
+ the trap is generated. (If it has never been set, the value will be -1.)"
+ ::= { sfcsBwPortPoolTrapMgmtEntry 35 }
+
+sfcsBwPortPoolTrapMgmtUBRConnCntTholdLoFwd OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " The lower threshold for the UBR connection count Fwd trap. When an
+ allocation causes the UBR connection count to fall below this value,
+ the trap is generated. (If it has never been set, the value will be -1.)"
+ ::= { sfcsBwPortPoolTrapMgmtEntry 36 }
+
+sfcsBwPortPoolTrapMgmtUBRConnCntTholdLoRev OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " The lower threshold for the UBR connection count Rev trap. When an
+ allocation causes the UBR connection count to fall below this value,
+ the trap is generated. (If it has never been set, the value will be -1.)"
+ ::= { sfcsBwPortPoolTrapMgmtEntry 37 }
+
+sfcsBwPortPoolTrapMgmtUBRAllocBwTholdHiFwd OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " The upper threshold for the UBR Allocated Bw Fwd trap. When an
+ allocation causes the UBR Allocated Bw to exceed this value,
+ the trap is generated. (If it has never been set, the value will be -1.)"
+ ::= { sfcsBwPortPoolTrapMgmtEntry 38 }
+
+sfcsBwPortPoolTrapMgmtUBRAllocBwTholdHiRev OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " The upper threshold for the UBR Allocated Bw Rev trap. When an
+ allocation causes the UBR Allocated Bw to exceed this value,
+ the trap is generated. (If it has never been set, the value will be -1.)"
+ ::= { sfcsBwPortPoolTrapMgmtEntry 39 }
+
+sfcsBwPortPoolTrapMgmtUBRAllocBwTholdLoFwd OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " The lower threshold for the UBR Allocated Bw Fwd trap. When an
+ allocation causes the UBR Allocated Bw to fall below this value,
+ the trap is generated. (If it has never been set, the value will be -1.)"
+ ::= { sfcsBwPortPoolTrapMgmtEntry 40 }
+
+sfcsBwPortPoolTrapMgmtUBRAllocBwTholdLoRev OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " The lower threshold for the UBR Allocated Bw Rev trap. When an
+ allocation causes the UBR Allocated Bw to fall below this value,
+ the trap is generated. (If it has never been set, the value will be -1.)"
+ ::= { sfcsBwPortPoolTrapMgmtEntry 41 }
+
+sfcsBWPortPoolTrapMgmtBuffUpThold OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " The upper threshold for buffer allocation trap ."
+ ::= { sfcsBwPortPoolTrapMgmtEntry 42 }
+
+sfcsBWPortPoolTrapMgmtBuffLoThold OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " The lower threshold for buffer allocation trap ."
+ ::= { sfcsBwPortPoolTrapMgmtEntry 43 }
+
+sfcsBWPortPoolTrapMgmtConnRejThold OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " The lower threshold for conn rejects trap ."
+ ::= { sfcsBwPortPoolTrapMgmtEntry 44 }
+
+
+-- %%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
+-- ### Buffer Pool Information
+
+-- Each Buffer Pool consists of a number of rows- one for each priority
+-- The primary index is the ifindex of the port that owns these row entries
+-- The secondary index is the priority number for the row
+
+--
+sfcsBuffPrioTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SfcsBuffPrioEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "This table contains the rows of all the buffer pools."
+ ::= { sfcsBuffPools 1 }
+
+sfcsBuffPrioEntry OBJECT-TYPE
+ SYNTAX SfcsBuffPrioEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Each entry contains the rows of all the buffer pools."
+ INDEX { sfcsBuffPrioPortIndex, sfcsBuffPrioPriority }
+ ::= { sfcsBuffPrioTable 1 }
+
+SfcsBuffPrioEntry ::=
+ SEQUENCE {
+ sfcsBuffPrioPortIndex INTEGER,
+ sfcsBuffPrioPriority INTEGER,
+ sfcsBuffPrioAssignCtl INTEGER,
+ sfcsBuffPrioMinCtl INTEGER,
+ sfcsBuffPrioAssigned INTEGER,
+ sfcsBuffPrioAllocated INTEGER,
+ sfcsBuffPrioAvailable INTEGER,
+ sfcsBuffPrioPeakAlloc INTEGER,
+ sfcsBuffPrioConnRejs INTEGER,
+ sfcsBuffPrioUpTholdTrap INTEGER,
+ sfcsBuffPrioLoTholdTrap INTEGER,
+ sfcsBuffPrioConnRejThold INTEGER
+ }
+
+-- ### Entry Defs
+sfcsBuffPrioPortIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This index specifies which port we are dealing
+ with. This reference is in the same format as MIB II's
+ Interface index."
+ ::= { sfcsBuffPrioEntry 1 }
+
+sfcsBuffPrioPriority OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This index specifies which priority we are dealing
+ with."
+ ::= { sfcsBuffPrioEntry 2 }
+
+
+sfcsBuffPrioAssignCtl OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ " The status of how assignment is controlled. Static,Manual,Adaptive. "
+ ::= { sfcsBuffPrioEntry 3}
+
+sfcsBuffPrioMinCtl OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " The minimum number of cells which can be assigned to this
+ port/prioity."
+ ::= { sfcsBuffPrioEntry 4}
+
+sfcsBuffPrioAssigned OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " The number of cells which are currently assigned to this
+ port/priority."
+ ::= { sfcsBuffPrioEntry 5}
+
+sfcsBuffPrioAllocated OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ " The number of assigned cells which are currently allocated to
+ VCs for this port/priority."
+ ::= { sfcsBuffPrioEntry 6}
+
+sfcsBuffPrioAvailable OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ " The number of assigned cells which are free to be allocated."
+ ::= { sfcsBuffPrioEntry 7}
+
+sfcsBuffPrioPeakAlloc OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ " The peak number of cells which have been allocated to this
+ port/priority."
+ ::= { sfcsBuffPrioEntry 8}
+
+sfcsBuffPrioConnRejs OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " The number of connections rejected because of a lack of buffers."
+ ::= { sfcsBuffPrioEntry 9}
+
+sfcsBuffPrioUpTholdTrap OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " The upper threshold of allocations to trigger an upper thold trap."
+ ::= { sfcsBuffPrioEntry 10}
+
+sfcsBuffPrioLoTholdTrap OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " The lower threshold of allocations to trigger a lower thold trap."
+ ::= { sfcsBuffPrioEntry 11}
+
+sfcsBuffPrioConnRejThold OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " The lower threshold of conn rejects trap because of inadequate buffers."
+ ::= { sfcsBuffPrioEntry 12}
+
+-- %%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
+-- The SFCS ANIM Proxy Group
+
+-- SFCS ANIM Proxy Group
+-- This group contains the managed objects and functions used to setup and
+-- configure the SFCS ANIM Proxies. This group contains three sub-groups:
+-- configuration status, Transmit function setup, and Port Read
+
+-- SFCS ANIM Proxy Configuration Status Table
+-- This table contains contains information about the status of the Port or Proxy
+-- as a whole, as opposed to the receive and Transmit table which contain information
+-- about cells.
+
+sfcsProxyConfigTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SfcsProxyConfigEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "This table contains the config info and a port
+ reading function."
+ ::= { sfcsProxyConfig 1 }
+
+sfcsProxyConfigEntry OBJECT-TYPE
+ SYNTAX SfcsProxyConfigEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Each entry contains ANIM Proxy config info or a function."
+ INDEX { sfcsProxyConfigANIMIndex }
+ ::= { sfcsProxyConfigTable 1 }
+
+SfcsProxyConfigEntry ::=
+ SEQUENCE {
+ sfcsProxyConfigANIMIndex INTEGER,
+ sfcsProxyConfigNUMPORTS INTEGER,
+ sfcsProxyConfigTxMemSize INTEGER,
+ sfcsProxyConfigRxMaxPduSize INTEGER,
+ sfcsProxyConfigBandWidth INTEGER,
+ sfcsProxyConfigTransmitDone INTEGER,
+ sfcsProxyConfigReceiveFifoState INTEGER,
+ sfcsProxyConfigPortTransmitMode INTEGER,
+ sfcsProxyConfigReceiveFifoReset INTEGER,
+ sfcsProxyConfigTxFifoReset INTEGER,
+ sfcsProxyConfigReceiveMode INTEGER,
+ sfcsProxyConfigCaptureMode INTEGER,
+ sfcsProxyConfigInitPort INTEGER,
+ sfcsProxyConfigLoad INTEGER,
+ sfcsProxyConfigGumbo OCTET STRING
+ }
+
+sfcsProxyConfigANIMIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This index specifies which ANIM Proxy we are dealing
+ with. This reference is in the same format as MIB II's
+ Interface index."
+ ::= { sfcsProxyConfigEntry 1 }
+
+sfcsProxyConfigNUMPORTS OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the number of ports per Proxy which is always 4."
+ ::= { sfcsProxyConfigEntry 2 }
+
+sfcsProxyConfigTxMemSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the size of the port's Transmission memory in K.
+ The memory size is always 1K."
+ ::= { sfcsProxyConfigEntry 3 }
+
+sfcsProxyConfigRxMaxPduSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the size of the port's Transmission memory in K.
+ The memory size is always 1K."
+ ::= { sfcsProxyConfigEntry 4 }
+
+sfcsProxyConfigBandWidth OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the bandwidth for the port, which is ?????"
+ ::= { sfcsProxyConfigEntry 5 }
+
+sfcsProxyConfigTransmitDone OBJECT-TYPE
+ SYNTAX INTEGER {
+ yes (1),
+ no (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Checks if the Transmission has finished."
+ ::= { sfcsProxyConfigEntry 6 }
+
+sfcsProxyConfigReceiveFifoState OBJECT-TYPE
+ SYNTAX INTEGER {
+ full(1),
+ not-full(2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Checks if the port's receive Fifo is full or not."
+ ::= { sfcsProxyConfigEntry 7 }
+
+sfcsProxyConfigPortTransmitMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ stop(1),
+ start-stay(2),
+ reread(3)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Controls Transmission of cells in port Transmit memory."
+ ::= { sfcsProxyConfigEntry 8 }
+
+sfcsProxyConfigReceiveFifoReset OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS write-only
+ STATUS mandatory
+ DESCRIPTION
+ "Controls the receive buffer's memory. Reset clears memory."
+ ::= { sfcsProxyConfigEntry 9 }
+
+sfcsProxyConfigTxFifoReset OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS write-only
+ STATUS mandatory
+ DESCRIPTION
+ "Controls the port's transmit memory. Reset clears memory."
+ ::= { sfcsProxyConfigEntry 10 }
+
+sfcsProxyConfigReceiveMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ receiving (1),
+ not-receiving (2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Controls whether or not the port receives cells."
+ ::= { sfcsProxyConfigEntry 11 }
+
+sfcsProxyConfigCaptureMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ all (1),
+ header (2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Controls how much of the cell is received."
+ ::= { sfcsProxyConfigEntry 12 }
+
+sfcsProxyConfigInitPort OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS write-only
+ STATUS mandatory
+ DESCRIPTION
+ "Setting this returns the port to the initial setup."
+ ::= { sfcsProxyConfigEntry 13 }
+
+sfcsProxyConfigLoad OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Transmit load for port."
+ ::= { sfcsProxyConfigEntry 14 }
+
+sfcsProxyConfigGumbo OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Unreadable octet string used for control information."
+ ::= { sfcsProxyConfigEntry 15 }
+
+-- SFCS ANIM Proxy Transmit function setup Table.
+-- This table contains the function to send cells from specific ports and
+-- the arguments which this function takes.
+
+sfcsProxyTransTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SfcsProxyTransEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "This table contains the arguments and the function for the
+ Transmit function."
+ ::= { sfcsProxyTrans 1 }
+
+sfcsProxyTransEntry OBJECT-TYPE
+ SYNTAX SfcsProxyTransEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The entries are the arguments for the Transmit function."
+ INDEX { sfcsProxyTransANIMIndex }
+ ::= { sfcsProxyTransTable 1 }
+
+SfcsProxyTransEntry ::=
+ SEQUENCE {
+ sfcsProxyTransANIMIndex INTEGER,
+ sfcsProxyTransEncodeNewPdu INTEGER,
+ sfcsProxyTransVPI INTEGER,
+ sfcsProxyTransVCI INTEGER,
+ sfcsProxyTransPTI INTEGER,
+ sfcsProxyTransCLP INTEGER,
+ sfcsProxyTransPayloadType INTEGER,
+ sfcsProxyTransPayloadLength INTEGER,
+ sfcsProxyTransPayloadData OCTET STRING,
+ sfcsProxyTransCount INTEGER,
+ sfcsProxyTransPayloadAdaptionLayer INTEGER,
+ sfcsProxyTransMpxMethod INTEGER,
+ sfcsProxyTransControl INTEGER,
+ sfcsProxyTransGumbo OCTET STRING
+ }
+
+sfcsProxyTransANIMIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This index specifies which ANIM Port we are dealing
+ with. This reference is in the same format as MIB II's
+ Interface Index."
+ ::= { sfcsProxyTransEntry 1 }
+
+sfcsProxyTransEncodeNewPdu OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS write-only
+ STATUS mandatory
+ DESCRIPTION
+ "Setting this encodes a new PDU based on the current PDU parameters
+ into the port's transmit memory."
+ ::= { sfcsProxyTransEntry 2 }
+
+sfcsProxyTransVPI OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This is the VPI for the PDU."
+ ::= { sfcsProxyTransEntry 3 }
+
+
+sfcsProxyTransVCI OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This is the VCI for the PDU."
+ ::= { sfcsProxyTransEntry 4 }
+
+sfcsProxyTransPTI OBJECT-TYPE
+ SYNTAX INTEGER (0..7)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Payload Type Indicator: the value of the 3 bit Payload Type
+ field in the header. The most signifigant bit indicates user or
+ control data, the next bit indicates congestion, and the
+ last bit indicates AAL encoding."
+ ::= { sfcsProxyTransEntry 5 }
+
+sfcsProxyTransCLP OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The cell loss priority: 1 or 0."
+ ::= { sfcsProxyTransEntry 6 }
+
+sfcsProxyTransPayloadType OBJECT-TYPE
+ SYNTAX INTEGER {
+ user-input(1),
+ sequential(2),
+ uniform(3)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The payload type for the cell."
+ ::= { sfcsProxyTransEntry 7 }
+
+sfcsProxyTransPayloadLength OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The length of the payload in bytes."
+ ::= { sfcsProxyTransEntry 8 }
+
+sfcsProxyTransPayloadData OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "If the payload type is user input, this is the payload itself."
+ ::= { sfcsProxyTransEntry 9 }
+
+sfcsProxyTransCount OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Number of copies of the pdu to encode in port transmit memory."
+ ::= { sfcsProxyTransEntry 10 }
+
+sfcsProxyTransPayloadAdaptionLayer OBJECT-TYPE
+ SYNTAX INTEGER {
+ raw(1),
+ aal5(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The format of the payload: either raw cells or AAL5."
+ ::= { sfcsProxyTransEntry 11 }
+
+sfcsProxyTransMpxMethod OBJECT-TYPE
+ SYNTAX INTEGER
+--{
+-- enumerate me!!
+-- }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The format of the payload: either raw cells or AAL5."
+ ::= { sfcsProxyTransEntry 12 }
+
+
+sfcsProxyTransControl OBJECT-TYPE
+ SYNTAX INTEGER {
+ send-once(1),
+ repeat(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Controls how many times to send what's in the port's
+ transmit memory."
+ ::= { sfcsProxyTransEntry 13 }
+
+sfcsProxyTransGumbo OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Returns the vpi, vci, pti, clp, payload_type, payload_length, count,
+ PAL, mpx method, and control entires for this table in a string where
+ the entries are separated by semicolons."
+ ::= { sfcsProxyTransEntry 14 }
+
+-- SFCS ANIM Port Read
+-- This table contains the information read from cells from a port's receive fifo.
+
+sfcsProxyReadTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SfcsProxyReadEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "This table contains information read from the cells in the receive fifo."
+ ::= { sfcsProxyRead 1 }
+
+sfcsProxyReadEntry OBJECT-TYPE
+ SYNTAX SfcsProxyReadEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The entries are the information about the cells or the PDU."
+ INDEX { sfcsProxyReadANIMIndex }
+ ::= { sfcsProxyReadTable 1 }
+
+SfcsProxyReadEntry ::=
+ SEQUENCE {
+ sfcsProxyReadANIMIndex INTEGER,
+ sfcsProxyReadMode INTEGER,
+ sfcsProxyReadNewPdu INTEGER,
+ sfcsProxyReadGumbo OCTET STRING,
+ sfcsProxyReadVPI INTEGER,
+ sfcsProxyReadVCI INTEGER,
+ sfcsProxyReadPTI INTEGER,
+ sfcsProxyReadCLP INTEGER,
+ sfcsProxyReadDataLength INTEGER,
+ sfcsProxyReadData OCTET STRING,
+ sfcsProxyReadPal INTEGER,
+ sfcsProxyReadInbyteslosts INTEGER,
+ sfcsProxyReadInCells INTEGER,
+ sfcsProxyReadInError INTEGER,
+ sfcsProxyReadInCellReadError INTEGER,
+ sfcsProxyReadInHecError INTEGER,
+ sfcsProxyReadInTooBigError INTEGER,
+ sfcsProxyReadInCRCError INTEGER,
+ sfcsProxyReadInLengthMismatchError INTEGER,
+ sfcsProxyReadInTotalCells INTEGER
+ }
+
+sfcsProxyReadANIMIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This index specifies which ANIM Port we are dealing
+ with. This reference is in the same format as the MIB II
+ Interface Index."
+ ::= { sfcsProxyReadEntry 1 }
+
+
+sfcsProxyReadMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ reassemble-PDU(1),
+ cell-by-cell(2),
+ all-data(3)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "How the receive fifo is read."
+ ::= { sfcsProxyReadEntry 2 }
+
+sfcsProxyReadNewPdu OBJECT-TYPE
+ SYNTAX INTEGER {
+ get-next-pdu(1),
+ reread-from-beginning(2)
+ }
+ ACCESS write-only
+ STATUS mandatory
+ DESCRIPTION
+ "Pops a new Pdu from the receive fifo to be examined and read."
+ ::= { sfcsProxyReadEntry 3 }
+
+sfcsProxyReadGumbo OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS write-only
+ STATUS mandatory
+ DESCRIPTION
+ "Unreadable control information."
+ ::= { sfcsProxyReadEntry 4 }
+
+sfcsProxyReadVPI OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This is the VPI for the PDU."
+ ::= { sfcsProxyReadEntry 5 }
+
+sfcsProxyReadVCI OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This is the VCI for the PDU."
+ ::= { sfcsProxyReadEntry 6 }
+
+sfcsProxyReadPTI OBJECT-TYPE
+ SYNTAX INTEGER (0..7)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Payload Type Indicator: the value of the 3 bit Payload Type
+ field in the header. The most signifigant bit indicates user or
+ control data, the next bit indicates congestion, and the
+ last bit indicates AAL encoding."
+ ::= { sfcsProxyReadEntry 7 }
+
+
+sfcsProxyReadCLP OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The cell loss priority: 1 or 0."
+ ::= { sfcsProxyReadEntry 8 }
+
+sfcsProxyReadDataLength OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The length of the PDU in bytes."
+ ::= { sfcsProxyReadEntry 9 }
+
+sfcsProxyReadData OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The actual data of the PDU."
+ ::= { sfcsProxyReadEntry 10 }
+
+sfcsProxyReadPal OBJECT-TYPE
+ SYNTAX INTEGER {
+ raw(1),
+ aal5(2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The format of the payload: either raw cells or AAL5."
+ ::= { sfcsProxyReadEntry 11 }
+
+sfcsProxyReadInbyteslosts OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of bytes that were dropped while reading. Usually because
+ they occurred before the Start of Cell was discovered."
+ ::= { sfcsProxyReadEntry 12 }
+
+sfcsProxyReadInCells OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of cells read since this port was last reset."
+ ::= { sfcsProxyReadEntry 13 }
+
+sfcsProxyReadInError OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of pdu's that had to be dropped due to errors."
+ ::= { sfcsProxyReadEntry 14 }
+
+sfcsProxyReadInCellReadError OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of cells that had to be dropped due to errors."
+ ::= { sfcsProxyReadEntry 15 }
+
+sfcsProxyReadInHecError OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of cell headers that contained errors."
+ ::= { sfcsProxyReadEntry 16 }
+
+sfcsProxyReadInTooBigError OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of pdu's that were too large to be received."
+ ::= { sfcsProxyReadEntry 17 }
+
+sfcsProxyReadInCRCError OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of pdu's that failed the CRC check."
+ ::= { sfcsProxyReadEntry 18 }
+
+sfcsProxyReadInLengthMismatchError OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The length stored in the pdu did not match the actual
+ length of the pdu read in."
+ ::= { sfcsProxyReadEntry 19 }
+
+sfcsProxyReadInTotalCells OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Total number of cells read in by the snapshot."
+ ::= { sfcsProxyReadEntry 20 }
+
+END