summaryrefslogtreecommitdiff
path: root/MIBS/enterasys/CTRON-SFPS-PKTMGR-MIB
diff options
context:
space:
mode:
authorDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
committerDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
commit98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch)
tree9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/enterasys/CTRON-SFPS-PKTMGR-MIB
downloadmibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.tar.gz
mibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.zip
Initial commitHEADmain
Diffstat (limited to 'MIBS/enterasys/CTRON-SFPS-PKTMGR-MIB')
-rw-r--r--MIBS/enterasys/CTRON-SFPS-PKTMGR-MIB721
1 files changed, 721 insertions, 0 deletions
diff --git a/MIBS/enterasys/CTRON-SFPS-PKTMGR-MIB b/MIBS/enterasys/CTRON-SFPS-PKTMGR-MIB
new file mode 100644
index 0000000..e9a6ae9
--- /dev/null
+++ b/MIBS/enterasys/CTRON-SFPS-PKTMGR-MIB
@@ -0,0 +1,721 @@
+CTRON-SFPS-PKTMGR-MIB DEFINITIONS ::= BEGIN
+
+-- sfps-pktmgr.mib.txt
+-- Revision: 0.0.15
+--
+-- Cabletron Systems, Inc.
+-- 35 Industria Way, P.O. Box 5005
+-- Rochester, NH 03867-0505
+-- (603) 332-9400
+-- support@ctron.com
+
+-- This module provides authoritative definitions for Cabletron's
+-- enterprise specific Fast Packet Switching MIB.
+--
+-- This module will be extended, as required.
+--
+
+-- Cabletron Systems reserves the right to make changes in
+-- specification and other information contained in this document
+-- without prior notice. The reader should consult Cabletron Systems
+-- to determine whether any such changes have been made.
+--
+-- In no event shall Cabletron Systems be liable for any incidental,
+-- indirect, special, or consequential damages whatsoever (including
+-- but not limited to lost profits) arising out of or related to this
+-- document or the information contained in it, even if Cabletron
+-- Systems has been advised of, known, or should have known, the
+-- possibility of such damages.
+--
+-- Cabletron grants vendors, end-users, and other interested parties
+-- a non-exclusive license to use this Specification in connection
+-- with the management of Cabletron products.
+-- Copyright October 93 Cabletron Systems
+--
+
+
+IMPORTS
+ OBJECT-TYPE
+ FROM RFC-1212
+-- DisplayString
+-- FROM RFC1213-MIB
+-- enterprises,
+-- IpAddress,
+-- Counter, TimeTicks, Gauge
+-- FROM RFC1155-SMI
+
+-- These Objects are defined in the file sfps-inc.mib.txt.0.0.12
+ sfpsSwitchSfpsPacket, sfpsCSPPacket, sfpsPktDispatchStats
+ FROM CTRON-SFPS-INCLUDE-MIB;
+
+
+-- Textual Conventions
+
+SfpsSwitchInstance ::= INTEGER
+-- this will map to chassis.module index value
+
+HexInteger ::= INTEGER
+-- display this integer in hex format
+
+
+--
+
+
+-- SFPS PacketManager Stats Table
+-- this table keeps track of the packets in the packetmanager
+--
+
+sfpsPacketMgrTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SfpsPacketMgrEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "This table keeps the statistics on all packets in the
+ packetmanager"
+ ::= { sfpsSwitchSfpsPacket 1 }
+
+sfpsPacketMgrEntry OBJECT-TYPE
+ SYNTAX SfpsPacketMgrEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Each entry describes part of the packetmanager table"
+ INDEX { sfpsPacketMgrSwitchID, sfpsPacketMgrPacketType }
+ ::= { sfpsPacketMgrTable 1 }
+
+SfpsPacketMgrEntry ::=
+ SEQUENCE {
+ sfpsPacketMgrSwitchID INTEGER,
+ sfpsPacketMgrPacketType HexInteger,
+ sfpsPacketMgrTotalPackets INTEGER,
+ sfpsPacketMgrPktsUsed INTEGER,
+ sfpsPacketMgrPktsAvailable INTEGER,
+ sfpsPacketMgrPktsInUse INTEGER,
+ sfpsPacketMgrNotFound INTEGER,
+ sfpsPacketMgrTooLarge INTEGER,
+ sfpsPacketMgrToCreate INTEGER,
+ sfpsPacketMgrReInit INTEGER
+ }
+
+sfpsPacketMgrSwitchID OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The switch instance of the switch"
+ ::= { sfpsPacketMgrEntry 1 }
+
+sfpsPacketMgrPacketType OBJECT-TYPE
+ SYNTAX HexInteger
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The packet type"
+ ::= { sfpsPacketMgrEntry 2 }
+
+sfpsPacketMgrTotalPackets OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The total number of packets created in the packetmanager"
+ ::= { sfpsPacketMgrEntry 3 }
+
+sfpsPacketMgrPktsUsed OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The total number of pkts used since beginning of
+ switch uptime"
+ ::= { sfpsPacketMgrEntry 4 }
+
+sfpsPacketMgrPktsAvailable OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of packets left in the packetmanager"
+ ::= { sfpsPacketMgrEntry 5 }
+
+sfpsPacketMgrPktsInUse OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of packets created minus the number of
+ packets left"
+ ::= { sfpsPacketMgrEntry 6 }
+
+sfpsPacketMgrNotFound OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of times a packet was requested and the
+ packetmanager did not have a packet of its size or
+ larger"
+ ::= { sfpsPacketMgrEntry 8 }
+
+sfpsPacketMgrTooLarge OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ ""
+ ::= { sfpsPacketMgrEntry 9 }
+
+sfpsPacketMgrToCreate OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Changes the number of packets in the PacketManager"
+ ::= { sfpsPacketMgrEntry 10 }
+
+sfpsPacketMgrReInit OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1),
+ reinit(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The lowest number of packets ever in the
+ packetmanager"
+ ::= { sfpsPacketMgrEntry 11 }
+--
+--
+--
+
+sfpsPacketListTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SfpsPacketListEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "This table keeps the statistics on all packets in the
+ packetmanager"
+ ::= { sfpsSwitchSfpsPacket 2 }
+
+sfpsPacketListEntry OBJECT-TYPE
+ SYNTAX SfpsPacketListEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Each entry describes part of the packetmanager table"
+ INDEX { sfpsPacketListPacketType, sfpsPacketListSize }
+ ::= { sfpsPacketListTable 1 }
+
+SfpsPacketListEntry ::=
+ SEQUENCE
+ {
+ sfpsPacketListPacketType HexInteger,
+ sfpsPacketListSize INTEGER,
+ sfpsPacketListTotalPackets INTEGER,
+ sfpsPacketListPktsUsed INTEGER,
+ sfpsPacketListPktsLeft INTEGER,
+ sfpsPacketListPktsInUse INTEGER,
+ sfpsPacketListLowWater INTEGER,
+ sfpsPacketListNotFound INTEGER,
+ sfpsPacketListStatus INTEGER
+ }
+
+sfpsPacketListPacketType OBJECT-TYPE
+ SYNTAX HexInteger
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The switch instance of the switch"
+ ::= { sfpsPacketListEntry 1 }
+
+sfpsPacketListSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The size of the packets that are located in this
+ particular sfpspacketlist"
+ ::= { sfpsPacketListEntry 2 }
+
+
+sfpsPacketListTotalPackets OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The total number of packets created in the packetmanager"
+ ::= { sfpsPacketListEntry 3 }
+
+sfpsPacketListPktsUsed OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The total number of pkts used since beginning of
+ switch uptime"
+ ::= { sfpsPacketListEntry 4 }
+
+sfpsPacketListPktsLeft OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of packets left in the packetmanager"
+ ::= { sfpsPacketListEntry 5 }
+
+sfpsPacketListPktsInUse OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of packets created minus the number of
+ packets left"
+ ::= { sfpsPacketListEntry 6 }
+
+sfpsPacketListLowWater OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The lowest number of packets ever in the
+ packetmanager"
+ ::= { sfpsPacketListEntry 7 }
+
+sfpsPacketListNotFound OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of times a packet was requested and the
+ packetmanager did not have a packet of its size or
+ larger"
+ ::= { sfpsPacketListEntry 8 }
+
+sfpsPacketListStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1),
+ enabled(2),
+ disabled(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Sets the administrative state of the packet list
+ for which the entry exists."
+ ::= { sfpsPacketListEntry 9 }
+
+--
+--
+--
+
+sfpsPacketSizeTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SfpsPacketSizeEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "This table keeps the statistics on all packets in the
+ packetmanager"
+ ::= { sfpsSwitchSfpsPacket 3 }
+
+sfpsPacketSizeEntry OBJECT-TYPE
+ SYNTAX SfpsPacketSizeEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Each entry describes part of the packetmanager table"
+ INDEX { sfpsPacketSizeSwitchInstance, sfpsPacketSizeSize }
+ ::= { sfpsPacketSizeTable 1 }
+
+SfpsPacketSizeEntry ::=
+ SEQUENCE
+ {
+ sfpsPacketSizeSwitchInstance SfpsSwitchInstance,
+ sfpsPacketSizeSize INTEGER,
+ sfpsPacketSizePktsUsed INTEGER,
+ sfpsPacketSizeNotFound INTEGER
+ }
+
+sfpsPacketSizeSwitchInstance OBJECT-TYPE
+ SYNTAX SfpsSwitchInstance
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The switch instance of the switch"
+ ::= { sfpsPacketSizeEntry 1 }
+
+sfpsPacketSizeSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The size of the packets that are located in this
+ particular sfpspacketSize"
+ ::= { sfpsPacketSizeEntry 2 }
+
+sfpsPacketSizePktsUsed OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The total number of pkts used since beginning of
+ switch uptime"
+ ::= { sfpsPacketSizeEntry 3 }
+
+sfpsPacketSizeNotFound OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of times a packet was requested and the
+ packetmanager did not have a packet of its size or
+ Larger"
+ ::= { sfpsPacketSizeEntry 4 }
+
+--
+--
+sfpsPacketQTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SfpsPacketQEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ ""
+ ::= { sfpsSwitchSfpsPacket 4 }
+
+sfpsPacketQEntry OBJECT-TYPE
+ SYNTAX SfpsPacketQEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ ""
+ INDEX { sfpsPacketQPriorityQ }
+ ::= { sfpsPacketQTable 1 }
+
+SfpsPacketQEntry ::=
+ SEQUENCE
+ {
+ sfpsPacketQPriorityQ INTEGER,
+ sfpsPacketQTotalPackets INTEGER,
+ sfpsPacketQCurrent INTEGER,
+ sfpsPacketQHighWater INTEGER
+ }
+
+sfpsPacketQPriorityQ OBJECT-TYPE
+ SYNTAX INTEGER {
+ low(1),
+ medium(2),
+ high(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ ""
+ ::= { sfpsPacketQEntry 1 }
+
+
+sfpsPacketQTotalPackets OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ ""
+ ::= { sfpsPacketQEntry 2 }
+
+
+sfpsPacketQCurrent OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ ""
+ ::= { sfpsPacketQEntry 3 }
+
+sfpsPacketQHighWater OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ ""
+ ::= { sfpsPacketQEntry 4 }
+
+-- CSP Packet Statistics
+
+sfpsCSPPacketStatsPacketsSentBad OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ ""
+ ::= { sfpsCSPPacket 1 }
+
+sfpsCSPPacketStatsPacketsSentGood OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ ""
+ ::= { sfpsCSPPacket 2 }
+
+sfpsCSPPacketStatsPacketsReceivedBad OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ ""
+ ::= { sfpsCSPPacket 3 }
+
+sfpsCSPPacketStatsPacketsReceivedGood OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ ""
+ ::= { sfpsCSPPacket 4 }
+
+-- SFPS Packet Dispatch Statistics keeps track of all packets dropped
+
+sfpsPktDispatchStatsVerb OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1),
+ resetAllStats(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ ""
+ ::= { sfpsPktDispatchStats 1 }
+
+
+numHPMInvalidFrameTypeDrops OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ ""
+ ::= { sfpsPktDispatchStats 2 }
+
+numHPMFilterMgtPortDrops OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ ""
+ ::= { sfpsPktDispatchStats 3 }
+
+numHPMPhysToLogPortDrops OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ ""
+ ::= { sfpsPktDispatchStats 4 }
+
+numHPMNullSFPSPktDrops OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ ""
+ ::= { sfpsPktDispatchStats 5 }
+
+numHPM81fdThrottleDrops OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ ""
+ ::= { sfpsPktDispatchStats 6 }
+
+numHPM81ffThrottleDrops OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ ""
+ ::= { sfpsPktDispatchStats 7 }
+
+numHPMPhysStandbyMaskDrops OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ ""
+ ::= { sfpsPktDispatchStats 8 }
+
+numBSInvSrcPortDrops OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ ""
+ ::= { sfpsPktDispatchStats 9 }
+
+numBSSourceBlockDrops OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ ""
+ ::= { sfpsPktDispatchStats 10 }
+
+numBSViolationDrops OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ ""
+ ::= { sfpsPktDispatchStats 11 }
+
+numBSUnknownPortDrops OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ ""
+ ::= { sfpsPktDispatchStats 12 }
+
+numBSStandbyPortDrops OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ ""
+ ::= { sfpsPktDispatchStats 13 }
+
+numBSFabricNghbrPortDrops OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ ""
+ ::= { sfpsPktDispatchStats 14 }
+
+numBSGoingToAccessPortDrops OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ ""
+ ::= { sfpsPktDispatchStats 15 }
+
+numBSInvPortTypeDrops OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ ""
+ ::= { sfpsPktDispatchStats 16 }
+
+numBSNullCallDrops OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ ""
+ ::= { sfpsPktDispatchStats 17 }
+
+numBSNullBottomCPDrops OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ ""
+ ::= { sfpsPktDispatchStats 18 }
+
+numBSInvCSPTypeDrops OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ ""
+ ::= { sfpsPktDispatchStats 19 }
+
+numBSNonHello81fdDrops OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ ""
+ ::= { sfpsPktDispatchStats 20 }
+
+numBSCSPCtrlDisableDrops OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ ""
+ ::= { sfpsPktDispatchStats 21 }
+
+numBSCSPCtrlIndexDrops OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ ""
+ ::= { sfpsPktDispatchStats 22 }
+
+numBCPNullCallDrops OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ ""
+ ::= { sfpsPktDispatchStats 23 }
+
+numBCPCPFaultedDrops OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ ""
+ ::= { sfpsPktDispatchStats 24 }
+
+numBCPGleanFailDrops OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ ""
+ ::= { sfpsPktDispatchStats 25 }
+
+numBCPCPHaltedDrops OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ ""
+ ::= { sfpsPktDispatchStats 26 }
+
+numBCPSwitchedBCADrops OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ ""
+ ::= { sfpsPktDispatchStats 27 }
+
+numBCPCallNotAcceptedDrops OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ ""
+ ::= { sfpsPktDispatchStats 28 }
+
+
+numHPM81fdNullPktDrops OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ ""
+ ::= { sfpsPktDispatchStats 29 }
+
+numHPM81fdHelloNullPktDrops OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ ""
+ ::= { sfpsPktDispatchStats 30 }
+
+END