summaryrefslogtreecommitdiff
path: root/MIBS/enterasys/CTRON-SMARTTRUNK-MIB
diff options
context:
space:
mode:
authorDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
committerDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
commit98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch)
tree9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/enterasys/CTRON-SMARTTRUNK-MIB
downloadmibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.tar.gz
mibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.zip
Initial commitHEADmain
Diffstat (limited to 'MIBS/enterasys/CTRON-SMARTTRUNK-MIB')
-rw-r--r--MIBS/enterasys/CTRON-SMARTTRUNK-MIB443
1 files changed, 443 insertions, 0 deletions
diff --git a/MIBS/enterasys/CTRON-SMARTTRUNK-MIB b/MIBS/enterasys/CTRON-SMARTTRUNK-MIB
new file mode 100644
index 0000000..ad7c64d
--- /dev/null
+++ b/MIBS/enterasys/CTRON-SMARTTRUNK-MIB
@@ -0,0 +1,443 @@
+CTRON-SMARTTRUNK-MIB DEFINITIONS ::= BEGIN
+
+-- ctron-smarttrunk-mib.txt
+-- Revision: 01.00.01
+-- Part Number:
+-- Date: April 14, 1999
+
+-- Cabletron Systems, Inc.
+-- 35 Industrial Way, P.O. Box 5005
+-- Rochester, NH 03867-0505
+-- (603) 332-9400
+-- support@ctron.com
+
+-- This module provides authoritative definitions for Cabletron's
+-- enterprise-specific port-trunking MIB.
+
+--
+-- This module will be extended, as needed.
+
+-- Cabletron Systems reserves the right to make changes in
+-- specification and other information contained in this document
+-- without prior notice. The reader should consult Cabletron Systems
+-- to determine whether any such changes have been made.
+--
+-- In no event shall Cabletron Systems be liable for any incidental,
+-- indirect, special, or consequential damages whatsoever (including
+-- but not limited to lost profits) arising out of or related to this
+-- document or the information contained in it, even if Cabletron
+-- Systems has been advised of, known, or should have known, the
+-- possibility of such damages.
+--
+-- Cabletron grants vendors, end-users, and other interested parties
+-- a non-exclusive license to use this Specification in connection
+-- with the management of Cabletron products.
+
+-- Copyright February 1999 Cabletron Systems
+
+-- Note: the design of this MIB owes much to designers of the LEC MIB.
+-- Rev: 1.00.01 cleaned up some spaces to allow import into Spectrum MIB Tools.
+IMPORTS
+ MODULE-IDENTITY, OBJECT-TYPE, Integer32, Counter32
+ FROM SNMPv2-SMI
+ TEXTUAL-CONVENTION, RowStatus, DisplayString, TruthValue
+ FROM SNMPv2-TC
+ MODULE-COMPLIANCE, OBJECT-GROUP
+ FROM SNMPv2-CONF
+ InterfaceIndex, ifIndex
+ FROM IF-MIB
+ ctSmartTrunkBranch
+ FROM CTRON-MIB-NAMES;
+
+ctSmartTrunk MODULE-IDENTITY
+ LAST-UPDATED "199812160000Z"
+ ORGANIZATION "Cabletron Systems, Inc"
+ CONTACT-INFO
+ "Cabletron Systems, Inc.
+ 35 Industrial Way, P.O. Box 5005
+ Rochester, NH 03867-0505
+ (603) 332-9400
+ support@cabletron.com
+ http://www.ctron.com"
+ DESCRIPTION
+ "This mib module defines a portion of the SNMP enterprise MIBs under Cabletron
+ enterprise OID pertaining to configuration of Smart TRUNK network links."
+ ::= { ctSmartTrunkBranch 1 }
+
+ctSmartTrunkConfig OBJECT IDENTIFIER ::= { ctSmartTrunk 1 }
+ctSmartTrunkDebug OBJECT IDENTIFIER ::= { ctSmartTrunk 2 }
+
+-- Textual Conventions
+
+ CTSmartTrunkProtocol ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "Type of trunking protocol used. LLAP based switches should use decHuntGroup.
+ noProcol applies to all other types of connections."
+ SYNTAX INTEGER {
+ noProtocol(1),
+ decHuntGroup(2)
+ }
+
+ CTSmartTrunkIndex ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "Most of the tables in this MIB are indexed in whole
+ or in part by 'ctTrunkIndex' - not by 'ifIndex'.
+ Why is there a separate index?
+ Traditionally, ifIndex values are chosen by agents,
+ and are permitted to change across restarts. Using
+ ifIndex to index ctTrunkConfigTable could complicate
+ row creation and/or cause interoperability problems
+ (if each agent had special restrictions on ifIndex).
+ Having a separate index avoids these problems."
+ SYNTAX INTEGER ( 1..2147483647 )
+
+ CTSmartTrunkName ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "A textual description of this virtual port."
+ SYNTAX DisplayString (SIZE(0..32))
+
+ CTSmartTrunkLoadBalanceType ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "The algorithm in use to assign flows to each link in a Smart TRUNK."
+ SYNTAX INTEGER {
+ balancingUnspecified(1),
+ roundRobin(2),
+ linkUtilization(3)
+ }
+
+--
+-- Smart Trunk Configuration
+--
+
+ ctTrunkGlobalStatus OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The state of Smart TRUNK capability for this entire managed entity. Default Value is True(1). If set to False(2)
+ all smart trunks are put into ifAdminStatus down."
+ ::= { ctSmartTrunkConfig 1 }
+
+ ctTrunkConfigTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CtTrunkConfigEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table describing all of the trunk interfaces
+ implemented by this host. Each trunk has a row
+ in the MIB-II/RFC 2233 Interfaces table (describing
+ the structure of the trunk interface it presents to higher
+ layers). Each trunk interface also has a row in this and
+ other CTRON-SMARTTRUNK-MIB tables. Smart Trunks use
+ ifType propMultiplexor(54). Counters represent the aggregate of
+ all physcal links.
+
+ Unlike hardware ports, trunk interfaces can be created by
+ management. However, the RFC 2233 Interfaces table
+ does not directly support row creation. Therefore,
+ creating or deleting a row in the ctTrunkConfigTable is
+ defined to have the side effect of creating or
+ deleting corresponding rows in
+
+ - the MIB-II / RFC 2233 Interfaces table,
+ - any other dependent tables
+
+ New Interfaces table rows for trunk intefaces
+ always have 'ifAdminStatus' set to 'down' until the row
+ state is becomes Active. Then administration of the
+ interface uses normal ifTable ifAdminStatus to enabled it."
+
+ ::= { ctSmartTrunkConfig 3 }
+
+ ctTrunkConfigEntry OBJECT-TYPE
+ SYNTAX CtTrunkConfigEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Each table entry contains configuration information for one trunk interface."
+ INDEX { ctTrunkIndex }
+ ::= { ctTrunkConfigTable 1 }
+
+ CtTrunkConfigEntry ::=
+ SEQUENCE {
+ ctTrunkIndex CTSmartTrunkIndex,
+ ctTrunkConfigName CTSmartTrunkName,
+ ctTrunkConfigProtocol CTSmartTrunkProtocol,
+ ctTrunkConfigLoadBalance CTSmartTrunkLoadBalanceType,
+ ctTrunkIfIndex InterfaceIndex,
+ ctTrunkRowStatus RowStatus
+ }
+
+ ctTrunkIndex OBJECT-TYPE
+ SYNTAX CTSmartTrunkIndex
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A value which uniquely identifies this conceptual
+ row in the ctTrunkConfigTable. The Table allows sparse values.
+
+ If the conceptual row identified by this value of
+ ctTrunkIndex is recreated following an agent restart,
+ the same value of ctTrunkIndex must be used to identify
+ the recreated row. (However, the Interfaces table
+ index associated with the client may change. ifAlias in ifXTable is used
+ then to reassociate ifIndexes based on ifAlias. In the case of the SSR,
+ Smart Trunks are manipulated as st.ctTrunkIndex"
+ ::= { ctTrunkConfigEntry 1 }
+
+ ctTrunkConfigName OBJECT-TYPE
+ SYNTAX CTSmartTrunkName
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The Trunk's Name, just for informational purposes. It may be changed
+ regardless of the RowStatus value."
+
+ DEFVAL { "" }
+ ::= { ctTrunkConfigEntry 2 }
+
+ ctTrunkConfigProtocol OBJECT-TYPE
+ SYNTAX CTSmartTrunkProtocol
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Trunking protocol in use. Once the row is active, it can not be changed."
+ DEFVAL { decHuntGroup }
+ ::= { ctTrunkConfigEntry 3 }
+
+ ctTrunkConfigLoadBalance OBJECT-TYPE
+ SYNTAX CTSmartTrunkLoadBalanceType
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The type of load balance algorithm applied to this trunk.
+ Once Row is active, the agent may override this value with an implmentation specific
+ default."
+ DEFVAL { balancingUnspecified }
+ ::= { ctTrunkConfigEntry 4 }
+
+ ctTrunkIfIndex OBJECT-TYPE
+ SYNTAX InterfaceIndex
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The ifIndex in ifTable, ifXTable that is associated with the trunk that is
+ represented by this row."
+ ::= { ctTrunkConfigEntry 5 }
+
+ ctTrunkRowStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object lets network managers create and delete
+ trunk interfaces, on systems that support this
+ optional capability.
+
+ It does not control the activation and deactivation
+ of these interfaces; they are controlled by 'ifAdminStatus'
+ in the ifTable. However, changing row state from active
+ to notInService. will have the side effect of changing
+ their 'ifAdminStatus' values to 'noPresent' or 'down',
+ thus causing any active trunk connections to be terminated.
+
+ When creating a trunk interface, it is up to the
+ management station to determine a suitable 'ctTrunkIndex'.
+ To facilitate interoperability, agents should not put
+ any restrictions on the 'ctTrunkIndex' beyond the obvious
+ ones that it be valid and unused.
+
+ The Managed Objects that must be set in this table
+ for a row to change from nonExistent/notReady to notInService/Active
+ is simply an index. Ports can then be added to the Smart TRUNK
+ via the ifStackTable.
+
+ If you create a trunk interface via this object,
+ it will initially have
+ 'ifAdminStatus' = 'down'
+ 'ifOperStatus' = 'down' when RowStatus is changed to active."
+ ::= { ctTrunkConfigEntry 6 }
+
+ --
+ -- SmartTrunk Connection Table
+ --
+
+ ctTrunkConnectionTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CtTrunkConnectionEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table describes how local interfaces that are
+ participating in a trunk are connected to remote
+ interfaces.
+
+ With this table, a management entity can determine
+ that (for example) local interfaces 3, 4, and 6 are
+ connected to remote interfaces 10, 17, and 19.
+
+ This table is useful to debug configuration errors
+ with remote devices. If ifAdminStatus/ifOperState is
+ up, and no corresponding row is found in this table,
+ then a management station can assume a the remote
+ end does not have the decHuntGroup protocol active.
+
+ Note: this entire table is read-only. Rows are
+ created and deleted from this table as a side
+ effect of trunks being created and deleted.
+
+ Note: a managment entity could determine (for
+ example) that interface 3 was participating in
+ trunk 3 by using the ifStackTable and ctTrunkIfIndex."
+ ::= { ctSmartTrunkConfig 4 }
+
+ ctTrunkConnectionEntry OBJECT-TYPE
+ SYNTAX CtTrunkConnectionEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Each table entry contains configuration information
+ for one interface that is participating in a trunk."
+ INDEX { ifIndex }
+ ::= { ctTrunkConnectionTable 1 }
+
+ CtTrunkConnectionEntry ::=
+ SEQUENCE {
+ ctTrunkPortRemoteIfIndex InterfaceIndex
+ }
+
+ ctTrunkPortRemoteIfIndex OBJECT-TYPE
+ SYNTAX InterfaceIndex
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The ifIndex of the interface at the other end of
+ this part of the trunk link. If this value is 0,
+ then for some reason there is no interface on the
+ other side of this link. This might be a temporary
+ condition or it might represent a real problem.
+
+ Note: this table is indexed by ifIndex. So the
+ index is the local ifIndex value and
+ ctTrunkPortRemoteIfIndex is the remote ifIndex."
+ ::= { ctTrunkConnectionEntry 1 }
+
+-- END of ctTrunkConnectionTable
+
+ ctTrunkLLAPRequirement OBJECT-TYPE
+ SYNTAX INTEGER {
+ required(1),
+ notRequired(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates whether this managed entity requires the
+ LLAP updates to perform the trunking function.
+
+ Certain families of products require LLAP (decHuntGroup Protocol)
+ order for the Smart TRUNK functionality to work.
+ A value of 1 implies that LLAP is necessary for smart-trunking
+ to work on this platform, a value of 2 indicates that it is
+ not necessary."
+ ::= { ctSmartTrunkDebug 1 }
+
+ ctTrunkMaxTrunks OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The maximum number of trunks that can be configured
+ on this managed entity."
+ ::= { ctSmartTrunkDebug 2 }
+
+ -- The Trunk-Flow Diagnostic table
+ --
+ -- this table is optional; it will be implemented on those devices
+ -- that use "flows"
+ ctTrunkFlowDiagnosticTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CtTrunkFlowDiagnosticEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Provide a means to programmatically evaluate the load
+ balancing of a smart trunk. Assumes that load balancing is done on a
+ flow by flow basis."
+ ::= { ctSmartTrunkDebug 4 }
+
+ ctTrunkFlowDiagnosticEntry OBJECT-TYPE
+ SYNTAX CtTrunkFlowDiagnosticEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Each row refers to a specific smart trunk and port within
+ that smart trunk."
+ INDEX { ctTrunkIndex, ifIndex }
+ ::= { ctTrunkFlowDiagnosticTable 1 }
+
+ CtTrunkFlowDiagnosticEntry ::=
+ SEQUENCE {
+ ctTrunkFlowDiagnosticInstalledFlows Counter32
+ }
+
+ ctTrunkFlowDiagnosticInstalledFlows OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "A counter of the flows installed on this port since it was
+ first operational."
+ ::= { ctTrunkFlowDiagnosticEntry 1 }
+
+ -- END of ctTrunkFlowDiagnosticTable
+
+ --
+ -- Compliance
+ --
+
+ctTrunkConformance OBJECT IDENTIFIER ::= { ctSmartTrunk 3 }
+ctTrunkCompliances OBJECT IDENTIFIER ::= { ctTrunkConformance 1 }
+ctTrunkGroups OBJECT IDENTIFIER ::= { ctTrunkConformance 2 }
+
+ctTrunkComplianceV10 MODULE-COMPLIANCE
+ STATUS current
+ DESCRIPTION
+ "The compliance statement for the CTRON-SMARTTRUNK-MIB."
+ MODULE -- this module
+ MANDATORY-GROUPS { ctTrunkConfGroupV10 }
+
+ GROUP ctTrunkFlowDiagnosticGroup
+ DESCRIPTION
+ "This group is mandatory for all network devices
+ which utilize 'flows'. in order to pass packets along their
+ way."
+
+ ::= { ctTrunkCompliances 1 }
+
+ctTrunkConfGroupV10 OBJECT-GROUP
+ OBJECTS {
+ ctTrunkGlobalStatus,
+ ctTrunkRowStatus,
+ ctTrunkConfigName,
+ ctTrunkConfigProtocol,
+ ctTrunkConfigLoadBalance,
+ ctTrunkIfIndex,
+ ctTrunkPortRemoteIfIndex,
+ ctTrunkLLAPRequirement,
+ ctTrunkMaxTrunks
+}
+ STATUS current
+DESCRIPTION
+ "A set of managed objects that make up version 1.0 of the CTRON-SMARTTRUNK-MIB."
+ ::= { ctTrunkGroups 1 }
+
+ ctTrunkFlowDiagnosticGroup OBJECT-GROUP
+ OBJECTS { ctTrunkFlowDiagnosticInstalledFlows }
+ STATUS current
+ DESCRIPTION
+ "A collection of diagnostic information related to
+ interfaces participating in SmartTrunks; specifically
+ to interfaces on devices that use 'flows'."
+ ::= { ctTrunkGroups 2 }
+
+END