diff options
| author | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
|---|---|---|
| committer | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
| commit | 98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch) | |
| tree | 9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/ericsson/PT-RADIOLINK-MIB | |
| download | mibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.tar.gz mibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.zip | |
Diffstat (limited to 'MIBS/ericsson/PT-RADIOLINK-MIB')
| -rw-r--r-- | MIBS/ericsson/PT-RADIOLINK-MIB | 1663 |
1 files changed, 1663 insertions, 0 deletions
diff --git a/MIBS/ericsson/PT-RADIOLINK-MIB b/MIBS/ericsson/PT-RADIOLINK-MIB new file mode 100644 index 0000000..7741b87 --- /dev/null +++ b/MIBS/ericsson/PT-RADIOLINK-MIB @@ -0,0 +1,1663 @@ +PT-RADIOLINK-MIB DEFINITIONS ::= BEGIN + + IMPORTS + MODULE-IDENTITY,OBJECT-TYPE,Counter32, Integer32, IpAddress FROM SNMPv2-SMI + TEXTUAL-CONVENTION FROM SNMPv2-TC + MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF + InetAddressIPv6 FROM INET-ADDRESS-MIB + ifEntry FROM IF-MIB + pt FROM PT-MIB; + + + ptRadioLink MODULE-IDENTITY + LAST-UPDATED "201712011600Z" + ORGANIZATION "Ericsson" + CONTACT-INFO + "Anders Ekvall + Postal: Ericsson AB, + E-Mail: anders.ekvall@ericsson.com" + + DESCRIPTION + "This is the MIB for Radio Link specifics in PT" + + REVISION "201712011600Z" + DESCRIPTION + "Added plcAdminStatus and plcOperStatus." + + REVISION "201704051000Z" + DESCRIPTION + "Added channelSpacing enums." + + REVISION "201701181000Z" + DESCRIPTION + "Added mlhcAdminStatus, mlhcOperStatus and mlhcMplsConfig." + + REVISION "201612061400Z" + DESCRIPTION + "Added more MOs in ctTable and rltTable. Added G.826 tables." + + REVISION "201605221030Z" + DESCRIPTION + "The initial version of this MIB module + with OID for MINI-LINK." + + + ::= { pt 7 } + + ptRadioLinkConformance OBJECT IDENTIFIER ::= { ptRadioLink 2 } + ctPerformance OBJECT IDENTIFIER ::= { ptRadioLink 4 } + +--- +--- Textual conventions +--- + AcmTC ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "An integer which indicates the ACM." + SYNTAX INTEGER + { + acmHalfBpsk(1), + acmHalfBpskLight(2), + acmHalfBpskStrong(3), + acmBpsk(4), + acmBpskLight(5), + acmBpskStrong(6), + acm4Qam(7), + acm4QamLight(8), + acm4QamStrong(9), + acm16Qam(10), + acm16QamLight(11), + acm16QamStrong(12), + acm32Qam(13), + acm32QamLight(14), + acm32QamStrong(15), + acm64Qam(16), + acm64QamLight(17), + acm64QamStrong(18), + acm128Qam(19), + acm128QamLight(20), + acm128QamStrong(21), + acm256Qam(22), + acm256QamLight(23), + acm256QamStrong(24), + acm512Qam(25), + acm512QamLight(26), + acm512QamStrong(27), + acm1024Qam(28), + acm1024QamLight(29), + acm1024QamStrong(30), + acm2048Qam(31), + acm2048QamLight(32), + acm2048QamStrong(33), + acm4096Qam(34), + acm4096QamLight(35), + acm4096QamStrong(36) + } + + + EnableStatusTC ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "An integer which indicates the enabled status." + SYNTAX INTEGER + { + enabled(1), + disabled(2), + unknown(3) + } + + XpicMimoTC ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "An integer which indicates the XPIC or MIMO status." + SYNTAX INTEGER + { + notAvailable(1), + locked(2), + unlocked(3), + unknown(4) + } + +--- +---The definition of ctTable +--- + ctTable OBJECT-TYPE + SYNTAX SEQUENCE OF CtEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table of CT Table entries." + ::= { ptRadioLink 1 } + + ctEntry OBJECT-TYPE + SYNTAX CtEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry of CT application." + AUGMENTS { ifEntry } + ::= { ctTable 1 } + + CtEntry ::= + SEQUENCE { + actualInputPower OCTET STRING, + actualOutputPower OCTET STRING, + actualRxAcm OCTET STRING, + actualTxAcm OCTET STRING, + ctDistinguishedName OCTET STRING, + description OCTET STRING, + carrierId INTEGER, + ctStatus INTEGER, + frameId Integer32, + txFrequency Integer32, + minTxFrequency Integer32, + maxTxFrequency Integer32, + rxFrequency Integer32, + minRxFrequency Integer32, + maxRxFrequency Integer32, + frequencyStepSize Integer32, + duplexDistance Integer32, + duplexType INTEGER, + duplexConfig EnableStatusTC, + autoFreqSelection INTEGER, + autoFreqSelectedChannel Integer32, + autoFreqSelectionStatus INTEGER, + channelSpacing INTEGER, + polarization INTEGER, + txOperStatus INTEGER, + txAdminStatus INTEGER, + selectedOutputPowerType INTEGER, + availableOutputPowerType INTEGER, + selectedMinOutputPower Integer32, + selectedMaxOutputPower Integer32, + availableMinOutputPower Integer32, + availableMaxOutputPower Integer32, + referenceSec INTEGER, + targetInputPowerFarEnd Integer32, + berAlarmThreshold INTEGER, + inputPowerAlarmThreshold Integer32, + plannedAlignmentInputPower Integer32, + atpcFallback EnableStatusTC, + atpcFallbackTimer Integer32, + atpcFallbackOutputPower Integer32, + xpicStatus XpicMimoTC, + mimoStatus XpicMimoTC, + actualSnir OCTET STRING, + actualXpi OCTET STRING, + actualSi OCTET STRING, + actualTxCapacity Integer32, + licensedCapacity Integer32, + availableMinCapacity Integer32, + availableMaxCapacity Integer32, + selectedMinCapacity Integer32, + selectedMaxCapacity Integer32, + wantedLicensedCapacity Integer32, + availableMinAcm AcmTC, + availableMaxAcm AcmTC, + selectedMinAcm AcmTC, + selectedMaxAcm AcmTC, + actualRxAcmTC AcmTC, + actualTxAcmTC AcmTC, + alignmentMode EnableStatusTC, + rfLoop EnableStatusTC + } + + actualInputPower OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Actual input power of the CT in dBm" + ::= { ctEntry 1 } + + actualOutputPower OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Actual output power of the CT in dBm" + ::= { ctEntry 2 } + + actualRxAcm OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Actual rx modulation and coding" + ::= { ctEntry 3 } + + actualTxAcm OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Actual tx modulation and coding" + ::= { ctEntry 4 } + + ctDistinguishedName OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Unique id/name of the carrier termination, according to FDN (rack/slot/port/class)" + ::= { ctEntry 5 } + + description OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "User description of the carrior termination." + ::= { ctEntry 6 } + + carrierId OBJECT-TYPE + SYNTAX INTEGER + { + a(1), + b(2), + c(3), + d(4), + unknown(5) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Id of the carrier. (A, B, C, D) + Used in XPIC & MIMO configurations to check that the carrier termination is connected to the correct far end carrier termination. + Should be the same id on both sides of the hop. Defaulted when not MIMO or XPIC. + Sometimes also referred to as preamble" + ::= { ctEntry 7 } + + ctStatus OBJECT-TYPE + SYNTAX INTEGER + { + down(1), + up(2), + na(3), + unknown(4), + degraded(5) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The status of the carrier termination, hop" + ::= { ctEntry 8} + + frameId OBJECT-TYPE + SYNTAX Integer32 (0..10000) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "A unique identifier for the radio frame to be used. + Wanted frameId, txFrequency, rxFrequency, referenceSec, selectedMinAcm and selectedMaxAcm must be a valid combination." + ::= { ctEntry 9} + + txFrequency OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Selected frequency on the transmitter (kHz). + Wanted frameId, txFrequency, rxFrequency, referenceSec, selectedMinAcm and selectedMaxAcm must be a valid combination." + ::= { ctEntry 10} + + minTxFrequency OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Minimum Tx frequency possible to use, given by the selected frame-id" + ::= { ctEntry 11} + + maxTxFrequency OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Maximum Tx frequency possible to use, given by the selected frame-id" + ::= { ctEntry 12} + + rxFrequency OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Selected frequency on the receiver (kHz). + Wanted frameId, txFrequency, rxFrequency, referenceSec, selectedMinAcm and selectedMaxAcm must be a valid combination." + ::= { ctEntry 13} + + minRxFrequency OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Minimum Rx frequency possible to use, given by the selected frame-id" + ::= { ctEntry 14} + + maxRxFrequency OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Maximum Rx frequency possible to use, given by the selected frame-id" + ::= { ctEntry 15} + + frequencyStepSize OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Frequency step size in kHz" + ::= { ctEntry 16} + + duplexDistance OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Distance between Tx and Rx frequencies (kHz)" + ::= { ctEntry 17} + + duplexType OBJECT-TYPE + SYNTAX INTEGER + { + variable(1), + fixed(2), + unknown(3) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The duplex type is given by the equipment (Fixed,Variable)" + ::= { ctEntry 18} + + + duplexConfig OBJECT-TYPE + SYNTAX EnableStatusTC + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enabling or disabling configuration of Rx freq using duplex distance" + ::= { ctEntry 19} + + autoFreqSelection OBJECT-TYPE + SYNTAX INTEGER + { + disabled(1), + master(2), + slave(3), + unknown(4) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Automatic frequency selection mode" + ::= { ctEntry 20} + + autoFreqSelectedChannel OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Automatic frequency selected channel" + ::= { ctEntry 21} + + autoFreqSelectionStatus OBJECT-TYPE + SYNTAX INTEGER + { + idle(1), + searchingForSlave(2), + requestingInfoFromSlave(3), + waitingForMaster(4), + waitingForChannelInfoRequest(5), + inProgress(6), + initializing(7), + finished(8), + failed(9), + unknown(10) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Automatic frequency status" + ::= { ctEntry 22} + + channelSpacing OBJECT-TYPE + SYNTAX INTEGER + { + cs7MHz(1), + cs10MHz(2), + cs14MHz(3), + cs20MHz(4), + cs28MHz(5), + cs30MHz(6), + cs40MHz(7), + cs50MHz(8), + cs56MHz(9), + cs250MHz(10), + cs60MHz(11), + cs500MHz(12), + cs750MHz(13), + cs100MHz(14), + cs150MHz(15), + cs200MHz(16), + cs125MHz(17), + cs80MHz(18), + cs112MHz(19), + cs1000MHz(20), + cs1250MHz(21), + cs1500MHz(22), + cs62p5MHz(23), + cs2000MHz(24), + unknown(25) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Channel spacing" + ::= { ctEntry 23} + + polarization OBJECT-TYPE + SYNTAX INTEGER + { + notSpecified(1), + horizontal(2), + vertical(3), + unknown(4) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Antenna polarization" + ::= { ctEntry 24} + + txOperStatus OBJECT-TYPE + SYNTAX INTEGER + { + unknown(1), + off(2), + on(3), + standby(4) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Operative status of the transmitter" + ::= { ctEntry 25} + + txAdminStatus OBJECT-TYPE + SYNTAX INTEGER + { + off(1), + on(2), + unknown(3) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Administrative status of the transmitter" + ::= { ctEntry 26} + + selectedOutputPowerType OBJECT-TYPE + SYNTAX INTEGER + { + standard(1), + high(2), + unknown(3) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Selected output power type" + ::= { ctEntry 27} + + availableOutputPowerType OBJECT-TYPE + SYNTAX INTEGER + { + standard(1), + high(2), + unknown(3) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Available output power type" + ::= { ctEntry 28} + + selectedMinOutputPower OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Selected min output power. + Selected min & max output power should be set to the same value for RTPC mode, otherwise the hop operates in ATPC mode." + ::= { ctEntry 29} + + selectedMaxOutputPower OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Selected max output power. + Selected min & max output power should be set to the same value for RTPC mode, otherwise the hop operates in ATPC mode." + ::= { ctEntry 30} + + + availableMinOutputPower OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The minimum output power supported (dBm). + The system shows a value if the equipment is available and a frame id has been selected." + ::= { ctEntry 31} + + availableMaxOutputPower OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The maximum output power supported (dBm). + The system shows a value if the equipment is available and a frame id has been selected." + ::= { ctEntry 32} + + referenceSec OBJECT-TYPE + SYNTAX INTEGER + { + noAvailable(1), + sec2(2), + sec4L(4), + sec4H(5), + sec5B(7), + sec6B(9), + sec5LB(10), + sec5HB(11), + sec6LB(12), + sec6HB(13), + sec7B(14), + unknown(15) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Each modulation is compliant to a Reference Spectrum Efficiency Class (RSEC). + When running Adaptive Coding/Modulation, one SEC has to be selected for all the coding/modulations between selectedMinACM and selectedMaxACM. + This parameter is called Reference SEC. This setting will affect availableMaxOutputPower, in order to fulfill spectrum requirements. + Wanted frameId, txFrequency, rxFrequency, referenceSec, selectedMinAcm and selectedMaxAcm must be a valid combination." + ::= { ctEntry 33} + + targetInputPowerFarEnd OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The wanted input power at far end (dBm), when running ATPC" + ::= { ctEntry 34} + + berAlarmThreshold OBJECT-TYPE + SYNTAX INTEGER + { + tenExpMinus6(1), + tenExpMinus3(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Threshold for the BER alarm" + ::= { ctEntry 35} + + inputPowerAlarmThreshold OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Threshold for the input power alarm" + ::= { ctEntry 36} + + plannedAlignmentInputPower OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The planned received input power (dBm) dependent upon selected minimum ACM and corresponding output power. + Used when doing alignment" + ::= { ctEntry 37} + + atpcFallback OBJECT-TYPE + SYNTAX EnableStatusTC + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable or disable the output power fall back function" + ::= { ctEntry 38} + + atpcFallbackTimer OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Specifies the timer for output power fall back (# of seconds)" + ::= { ctEntry 39} + + atpcFallbackOutputPower OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The ATPC fallback output power" + ::= { ctEntry 40} + + xpicStatus OBJECT-TYPE + SYNTAX XpicMimoTC + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Status of the XPIC function." + ::= { ctEntry 41} + + mimoStatus OBJECT-TYPE + SYNTAX XpicMimoTC + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Status of the MIMO function." + ::= { ctEntry 42} + + actualSnir OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Actual signal to noise plus interference ratio (dB)." + ::= { ctEntry 43} + + actualXpi OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The carrier to cross-polar interference level (dBc)." + ::= { ctEntry 44} + + actualSi OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Spatial interference between the CTs when MIMO is configured." + ::= { ctEntry 45} + + actualTxCapacity OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Actual capacity supported by the carrier termination." + ::= { ctEntry 46} + + licensedCapacity OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Wanted or installed license for the capacity allowed for the carrier termination." + ::= { ctEntry 47} + + availableMinCapacity OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Minimum capacity possible to use. Given by the selected frame-id (kbit/s)" + ::= { ctEntry 48} + + availableMaxCapacity OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Maximum capacity possible to use. Given by the selected frame-id (kbit/s)" + ::= { ctEntry 49} + + selectedMinCapacity OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Selected minimum capacity, derived from selected minimum ACM (kbit/s)" + ::= { ctEntry 50} + + selectedMaxCapacity OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Selected maximum capacity, derived from selected maximum ACM (kbit/s)" + ::= { ctEntry 51} + + wantedLicensedCapacity OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Wanted licensed capacity and creation of LRF for the carrier termination (kbit/s)" + ::= { ctEntry 52} + + availableMinAcm OBJECT-TYPE + SYNTAX AcmTC + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Minimum ACM possible to use, given by the selected frame id." + ::= { ctEntry 53} + + availableMaxAcm OBJECT-TYPE + SYNTAX AcmTC + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Maximum ACM possible to use, given by the selected frame id" + ::= { ctEntry 54} + + selectedMinAcm OBJECT-TYPE + SYNTAX AcmTC + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Selected minimum coding/modulation. If selectedMinACM = selectedMaxACM, then the modulation is fixed" + ::= { ctEntry 55} + + selectedMaxAcm OBJECT-TYPE + SYNTAX AcmTC + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Selected maximum coding/modulation. If selectedMinACM = selectedMaxACM, then the modulation is fixed" + ::= { ctEntry 56} + + actualRxAcmTC OBJECT-TYPE + SYNTAX AcmTC + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Actual rx modulation and coding" + ::= { ctEntry 57} + + actualTxAcmTC OBJECT-TYPE + SYNTAX AcmTC + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Actual tx modulation and coding" + ::= { ctEntry 58} + + alignmentMode OBJECT-TYPE + SYNTAX EnableStatusTC + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable or disable the alignment mode" + ::= { ctEntry 59} + + rfLoop OBJECT-TYPE + SYNTAX EnableStatusTC + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable or disable the rf loop" + ::= { ctEntry 60} + + + --- + ---The definition of rltTable + --- + rltTable OBJECT-TYPE + SYNTAX SEQUENCE OF RltEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table of RLT Table entries." + ::= { ptRadioLink 3 } + + rltEntry OBJECT-TYPE + SYNTAX RltEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry of RLT application." + AUGMENTS { ifEntry } + ::= { rltTable 1 } + + RltEntry ::= + SEQUENCE { + rltDistinguishedName OCTET STRING, + neIpAddress IpAddress, + neIpv6Address InetAddressIPv6, + neName OCTET STRING, + neType INTEGER, + id OCTET STRING, + rltStatus INTEGER, + mode INTEGER, + actualTxTotalCapacity Integer32, + limitedTotalCapacity Integer32, + protectionStatus INTEGER, + revertiveWaitToRestore Integer32, + revertivePreferredTx INTEGER, + protectionSwitchMode INTEGER, + fadeNotificationTimer Integer32, + expectedFarEndId OCTET STRING, + farEndIdCheck INTEGER, + cpriMode INTEGER, + cpriStatus INTEGER, + manualSwitch INTEGER, + mlhcOperStatus INTEGER, + mlhcAdminStatus INTEGER, + mlhcMplsConfig INTEGER, + plcOperStatus INTEGER, + plcAdminStatus INTEGER + } + + rltDistinguishedName OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Unique id/name of the radio link termination, according to FDN (rack/slot/port/class)" + ::= { rltEntry 1 } + + neIpAddress OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "NE IP address" + ::= { rltEntry 2 } + + neIpv6Address OBJECT-TYPE + SYNTAX InetAddressIPv6 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "NE IP V6 address" + ::= { rltEntry 3 } + + neName OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "NE Name" + ::= { rltEntry 4 } + + neType OBJECT-TYPE + SYNTAX INTEGER + { + unknown(1), + mle(2), + xfMle(3), + tn(4), + cn(5), + pt(6) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "NE Type" + ::= { rltEntry 5 } + + id OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "User defined id of the radio link terminal" + ::= { rltEntry 6} + + rltStatus OBJECT-TYPE + SYNTAX INTEGER + { + down(1), + up(2), + na(3), + unknown(4), + degraded(5) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The status of the radio link terminal" + ::= { rltEntry 7} + + mode OBJECT-TYPE + SYNTAX INTEGER + { + mode1plus0(1), + mode1plus1CSB(2), + mode1plus1RLP(3), + mode2plus0RLB(4), + mode2plus1CSB(5), + mode2plus1RLP(6), + mode2plus2CSB(7), + mode2plus2RLP(8), + mode3plus0RLB(9), + mode4plus0RLB(10), + notAvailable11(11), + notAvailable12(12), + notAvailable13(13), + notAvailable14(14), + mode3plus1RLP(15), + mode3plus2RLP(16), + mode3plus3RLP(17), + mode4plus1RLP(18), + mode4plus2RLP(19), + mode4plus3RLP(20), + mode4plus4RLP(21), + notAvailable22(22), + notAvailable23(23), + notAvailable24(24), + notAvailable25(25), + notAvailable26(26), + notAvailable27(27), + mode3plus1CSB(28), + mode3plus2CSB(29), + mode3plus3CSB(30), + mode4plus1CSB(31), + mode4plus2CSB(32), + mode4plus3CSB(33), + mode4plus4CSB(34), + unknown(35) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The status of the radio link terminal" + ::= { rltEntry 8} + + actualTxTotalCapacity OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Actual aggregated total (packet + TDM) transmitter capacity for the radio link termination. + Limited by licenses & configuration (=nearEndLimitedCapacity) and depending on actual modulation/coding used at the moment." + ::= { rltEntry 9 } + + limitedTotalCapacity OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Maximum total capacity allowed by the current configuration and installed licenses. + Aggregated from the constituent carrier termination values." + ::= { rltEntry 10 } + + + protectionStatus OBJECT-TYPE + SYNTAX INTEGER + { + unprotected(1), + protected(2), + unableToProtect(3), + unknown(4) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Status of a protected node." + ::= { rltEntry 11} + + revertiveWaitToRestore OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The time, in number of seconds, to wait before switching back to the preferred Tx." + ::= { rltEntry 12} + + revertivePreferredTx OBJECT-TYPE + SYNTAX INTEGER + { + ct11(1), + ct12(2), + ct21(3), + ct22(4), + notApplicable(5), + unknown(6) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The preferred carrier termination transmitter." + ::= { rltEntry 13} + + + + protectionSwitchMode OBJECT-TYPE + SYNTAX INTEGER + { + auto(1), + manual(2), + autoAndRevertive(3), + unknown(4), + notApplicable(5) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + ".The mode in which the switching mechanism is configured" + ::= { rltEntry 14} + + + fadeNotificationTimer OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Notification is sent if fading is longer than this timer, applicable for protection." + ::= { rltEntry 15} + + expectedFarEndId OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Expected id of far-end terminal" + ::= { rltEntry 16 } + + farEndIdCheck OBJECT-TYPE + SYNTAX INTEGER + { + enabled(1), + disabled(2), + unknown(3) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enabling of far end id check." + ::= { rltEntry 17} + + cpriMode OBJECT-TYPE + SYNTAX INTEGER + { + master(1), + slave(2), + notApplicable(3), + unknown(4) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Set the mode of the CPRI front-haul product." + ::= { rltEntry 18} + + cpriStatus OBJECT-TYPE + SYNTAX INTEGER + { + idle(1), + waitingOnRtcSync(2), + waitingOnCpri(3), + waitingOnRxRequest(4), + waitingOnTxRequest(5), + inSync(6), + unknown(7) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The status of the CPRI front-haul product." + ::= { rltEntry 19} + + manualSwitch OBJECT-TYPE + SYNTAX INTEGER + { + ct11(1), + ct12(2), + ct21(3), + ct22(4), + notApplicable(5), + unknown(6) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Manual switch of protected carrier termination transmitter." + ::= { rltEntry 20} + + mlhcOperStatus OBJECT-TYPE + SYNTAX INTEGER + { + up(1), + down(2), + unknown(3) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Operative status of multi layer header compression." + ::= { rltEntry 21} + + mlhcAdminStatus OBJECT-TYPE + SYNTAX INTEGER + { + off(1), + on(2), + unknown(3) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Administrative status of multi layer header compression." + ::= { rltEntry 22} + + mlhcMplsConfig OBJECT-TYPE + SYNTAX INTEGER + { + controlWord(1), + l2(2), + l3(3), + mplsOnly(4), + unknown(5) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "MLHC/MPLS configuration." + ::= { rltEntry 23} + + plcOperStatus OBJECT-TYPE + SYNTAX INTEGER + { + up(1), + down(2), + unknown(3) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Operative status of payload compression." + ::= { rltEntry 24} + + plcAdminStatus OBJECT-TYPE + SYNTAX INTEGER + { + off(1), + on(2), + unknown(3) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Administrative status of payload compression." + ::= { rltEntry 25} + --- + ---The definition of ct826ContinuousTable + --- +ctG826ContinuousTable OBJECT-TYPE + SYNTAX SEQUENCE OF CtG826ContinuousEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table of CT G826 Performance Continuous counters entries. + The counters are reset by ctG826Reset" + ::= { ctPerformance 1 } + + ctG826ContinuousEntry OBJECT-TYPE + SYNTAX CtG826ContinuousEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry of CT G826 Performance Continuous counters." + AUGMENTS { ifEntry } + ::= { ctG826ContinuousTable 1 } + + CtG826ContinuousEntry ::= + SEQUENCE { + ctG826TimeElapsed Counter32, + ctBBE Counter32, + ctBBER OCTET STRING, + ctES Counter32, + ctESR OCTET STRING, + ctSES Counter32, + ctSESR OCTET STRING, + ctBB OCTET STRING, + ctUAS Counter32, + ctG826Reset INTEGER + } + + ctG826TimeElapsed OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Time elapsed in seconds since last PMReset" + ::= { ctG826ContinuousEntry 1 } + + ctBBE OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Background Block Errors" + ::= { ctG826ContinuousEntry 2 } + + ctBBER OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Background Block Errors Ratio" + ::= { ctG826ContinuousEntry 3 } + + ctES OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Error seconds" + ::= { ctG826ContinuousEntry 4 } + + ctESR OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Error seconds Ratio" + ::= { ctG826ContinuousEntry 5 } + + ctSES OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Severely error seconds" + ::= { ctG826ContinuousEntry 6 } + + ctSESR OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Severely error seconds Ratio" + ::= { ctG826ContinuousEntry 7 } + + ctBB OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Background blocks" + ::= { ctG826ContinuousEntry 8 } + + ctUAS OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Unavailable seconds " + ::= { ctG826ContinuousEntry 9 } + + ctG826Reset OBJECT-TYPE + SYNTAX INTEGER + { + other(1), + noReset(2), + reset(3) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Reset the continuous PM counters" + ::= { ctG826ContinuousEntry 10 } + + +--- +---The definition of ctG826Current15mTable +--- +ctG826Current15mTable OBJECT-TYPE + SYNTAX SEQUENCE OF CtG826Current15mEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table of CT Performance G826 15 m current counters Table entries." + ::= { ctPerformance 2 } + + ctG826Current15mEntry OBJECT-TYPE + SYNTAX CtG826Current15mEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry of CT Performance G826 15 m current Table counters." + AUGMENTS { ifEntry } + ::= { ctG826Current15mTable 1 } + + CtG826Current15mEntry ::= + SEQUENCE { + ctG826Current15mTimeElapsed Counter32, + ctCurrent15mBBE Counter32, + ctCurrent15mBBER OCTET STRING, + ctCurrent15mES Counter32, + ctCurrent15mESR OCTET STRING, + ctCurrent15mSES Counter32, + ctCurrent15mSESR OCTET STRING, + ctCurrent15mBB Counter32, + ctCurrent15mUAS Counter32 + } + + ctG826Current15mTimeElapsed OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Time elapsed in seconds since last PMReset" + ::= { ctG826Current15mEntry 1 } + + ctCurrent15mBBE OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Background Block Errors" + ::= { ctG826Current15mEntry 2 } + + ctCurrent15mBBER OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Background Block Errors Ratio" + ::= { ctG826Current15mEntry 3 } + + ctCurrent15mES OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Error seconds" + ::= { ctG826Current15mEntry 4 } + + ctCurrent15mESR OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Error seconds Ratio" + ::= { ctG826Current15mEntry 5 } + + ctCurrent15mSES OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Severely error seconds" + ::= { ctG826Current15mEntry 6 } + + ctCurrent15mSESR OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Severely error seconds Ratio" + ::= { ctG826Current15mEntry 7 } + + ctCurrent15mBB OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Background blocks" + ::= { ctG826Current15mEntry 8 } + + ctCurrent15mUAS OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Unavailable seconds " + ::= { ctG826Current15mEntry 9 } + +--- +---The definition of ctG826Current24hTable +--- +ctG826Current24hTable OBJECT-TYPE + SYNTAX SEQUENCE OF CtG826Current24hEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table of CT Performance G826 Current 24h counters entries." + ::= { ctPerformance 3 } + + ctG826Current24hEntry OBJECT-TYPE + SYNTAX CtG826Current24hEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry of CT Performance G826 Current 24 h counters." + AUGMENTS { ifEntry } + ::= { ctG826Current24hTable 1 } + + CtG826Current24hEntry ::= + SEQUENCE { + ctG826Current24hTimeElapsed Counter32, + ctCurrent24hBBE Counter32, + ctCurrent24hBBER OCTET STRING, + ctCurrent24hES Counter32, + ctCurrent24hESR OCTET STRING, + ctCurrent24hSES Counter32, + ctCurrent24hSESR OCTET STRING, + ctCurrent24hBB Counter32, + ctCurrent24hUAS Counter32 + } + + ctG826Current24hTimeElapsed OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Time elapsed in seconds since last PMReset" + ::= { ctG826Current24hEntry 1 } + + ctCurrent24hBBE OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Background Block Errors" + ::= { ctG826Current24hEntry 2 } + + ctCurrent24hBBER OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Background Block Errors Ratio" + ::= { ctG826Current24hEntry 3 } + + ctCurrent24hES OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Error seconds" + ::= { ctG826Current24hEntry 4 } + + ctCurrent24hESR OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Error seconds Ratio" + ::= { ctG826Current24hEntry 5 } + + ctCurrent24hSES OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Severely error seconds" + ::= { ctG826Current24hEntry 6 } + + ctCurrent24hSESR OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Severely error seconds Ratio" + ::= { ctG826Current24hEntry 7 } + + ctCurrent24hBB OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Background blocks" + ::= { ctG826Current24hEntry 8 } + + ctCurrent24hUAS OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Unavailable seconds " + ::= { ctG826Current24hEntry 9 } + +-- +-- Conformance +-- + + ptRadioLinkCompliances OBJECT IDENTIFIER ::= { ptRadioLinkConformance 1 } + ptRadioLinkGroups OBJECT IDENTIFIER ::= { ptRadioLinkConformance 2 } + + ptRadioLinkFullCompliance MODULE-COMPLIANCE + STATUS current + DESCRIPTION + "The compliance statement for SNMP entities which implement everything." + MODULE -- This Module + MANDATORY-GROUPS { ptRadioLinkCompleteGroup} + ::= { ptRadioLinkCompliances 1 } + + ptRadioLinkCompleteGroup OBJECT-GROUP + OBJECTS + { + actualInputPower, + actualOutputPower, + actualRxAcm, + actualRxAcmTC, + actualSi, + actualSnir, + actualTxAcm, + actualTxAcmTC, + actualTxCapacity, + actualTxTotalCapacity, + actualXpi, + alignmentMode, + atpcFallback, + atpcFallbackTimer, + atpcFallbackOutputPower, + autoFreqSelectedChannel, + autoFreqSelection, + autoFreqSelectionStatus, + availableMaxAcm, + availableMaxCapacity, + availableMaxOutputPower, + availableMinAcm, + availableMinCapacity, + availableMinOutputPower, + availableOutputPowerType, + berAlarmThreshold, + carrierId, + channelSpacing, + cpriMode, + cpriStatus, + ctDistinguishedName, + ctCurrent15mBB, + ctCurrent15mBBE, + ctCurrent15mBBER, + ctCurrent15mES, + ctCurrent15mESR, + ctCurrent15mSES, + ctCurrent15mSESR, + ctCurrent15mUAS, + ctG826Current15mTimeElapsed, + ctCurrent24hBB, + ctCurrent24hBBE, + ctCurrent24hBBER, + ctCurrent24hES, + ctCurrent24hESR, + ctCurrent24hSES, + ctCurrent24hSESR, + ctCurrent24hUAS, + ctG826Current24hTimeElapsed, + ctBB, + ctBBE, + ctBBER, + ctES, + ctESR, + ctG826Reset, + ctSES, + ctSESR, + ctG826TimeElapsed, + ctUAS, + ctStatus, + description, + duplexConfig, + duplexDistance, + duplexType, + expectedFarEndId, + fadeNotificationTimer, + farEndIdCheck, + frameId, + frequencyStepSize, + id, + inputPowerAlarmThreshold, + licensedCapacity, + limitedTotalCapacity, + manualSwitch, + maxRxFrequency, + maxTxFrequency, + mimoStatus, + minRxFrequency, + minTxFrequency, + mlhcAdminStatus, + mlhcMplsConfig, + mlhcOperStatus, + plcAdminStatus, + plcOperStatus, + mode, + neIpAddress, + neIpv6Address, + neName, + neType, + plannedAlignmentInputPower, + polarization, + protectionStatus, + protectionSwitchMode, + referenceSec, + revertivePreferredTx, + revertiveWaitToRestore, + rfLoop, + rltDistinguishedName, + rltStatus, + rxFrequency, + selectedMaxAcm, + selectedMaxCapacity, + selectedMaxOutputPower, + selectedMinAcm, + selectedMinCapacity, + selectedMinOutputPower, + selectedOutputPowerType, + targetInputPowerFarEnd, + txAdminStatus, + txFrequency, + txOperStatus, + wantedLicensedCapacity, + xpicStatus + } + STATUS current + DESCRIPTION + "A collection of all current objects in this MIB module." + ::= { ptRadioLinkGroups 1 } + + +END + |