+-- Rack Information MIB
+-- Management Information Base for SNMP Network Management
+--
+--
+-- Copyright 2002,2016 Hewlett Packard Enterprise Development LP
+--
+-- Hewlett Packard Enterprise shall not be liable for technical or
+-- editorial errors or omissions contained herein. The information in
+-- this document is provided "as is" without warranty of any kind and
+-- is subject to change without notice. The warranties for HPE products
+-- are set forth in the express limited warranty statements
+-- accompanying such products. Nothing herein should be construed as
+-- constituting an additional warranty.
+--
+-- Confidential computer software. Valid license from HPE required for
+-- possession, use or copying. Consistent with FAR 12.211 and 12.212,
+-- Commercial Computer Software, Computer Software Documentation, and
+-- Technical Data for Commercial Items are licensed to the U.S.
+-- Government under vendor's standard commercial license.
+--
+-- Refer to the READMIB.RDM file for more information about the
+-- organization of the information in the Compaq Enterprise.
+--
+-- The Compaq Enterprise number is 232.
+-- The ASN.1 prefix to, and including the Compaq Enterprise is:
+-- 1.3.6.1.4.1.232
+--
+-- ****************************************************************************
+
+CPQRACK-MIB DEFINITIONS ::= BEGIN
+
+ IMPORTS
+ compaq FROM CPQHOST-MIB
+ DisplayString FROM RFC1213-MIB
+ OBJECT-TYPE FROM RFC-1212
+ sysName FROM RFC1213-MIB
+ cpqHoTrapFlags FROM CPQHOST-MIB
+ TRAP-TYPE FROM RFC-1215
+ cpqHoOsType FROM CPQHOST-MIB
+ cpqHoVersion FROM CPQHOST-MIB;
+
+-- compaq OBJECT IDENTIFIER ::= { enterprises 232 }
+ cpqRackInfo OBJECT IDENTIFIER ::= { compaq 22 }
+ cpqRackMibRev OBJECT IDENTIFIER ::= { cpqRackInfo 1 }
+ cpqRackComponent OBJECT IDENTIFIER ::= { cpqRackInfo 2 }
+ cpqRackSysObjID OBJECT IDENTIFIER ::= { cpqRackInfo 3 }
+ cpqRackEventInfo OBJECT IDENTIFIER ::= { cpqRackInfo 4 }
+
+ cpqRackInterface OBJECT IDENTIFIER ::= { cpqRackComponent 1 }
+ cpqRackAsset OBJECT IDENTIFIER ::= { cpqRackComponent 2 }
+ cpqRackEnclosure OBJECT IDENTIFIER ::= { cpqRackComponent 3 }
+ cpqRackServer OBJECT IDENTIFIER ::= { cpqRackComponent 4 }
+ cpqRackPower OBJECT IDENTIFIER ::= { cpqRackComponent 5 }
+ cpqRackNetwork OBJECT IDENTIFIER ::= { cpqRackComponent 6 }
+ cpqRackHW OBJECT IDENTIFIER ::= { cpqRackComponent 7 }
+ cpqRackErs OBJECT IDENTIFIER ::= { cpqRackComponent 8 }
+
+ cpqRackOsCommon OBJECT IDENTIFIER ::= { cpqRackInterface 4 }
+
+ cpqRackCommonEnclosure OBJECT IDENTIFIER ::= { cpqRackEnclosure 1 }
+ cpqRackServerEnclosure OBJECT IDENTIFIER ::= { cpqRackEnclosure 2 }
+ cpqRackPowerEnclosure OBJECT IDENTIFIER ::= { cpqRackEnclosure 3 }
+
+ cpqRackServerBlade OBJECT IDENTIFIER ::= { cpqRackServer 1 }
+ cpqRackServerNetworking OBJECT IDENTIFIER ::= { cpqRackServer 2 }
+ cpqRackServerTempSensor OBJECT IDENTIFIER ::= { cpqRackServer 3 }
+
+ cpqRackPowerSupply OBJECT IDENTIFIER ::= { cpqRackPower 1 }
+
+ cpqRackNetConnector OBJECT IDENTIFIER ::= { cpqRackNetwork 1 }
+
+-- ****************************************************************************
+-- Rack Information MIB Revision
+-- =============================
+--
+-- The compaq enterprise (1.3.6.1.4.1.232)
+-- cpqRackInfo Group (1.3.6.1.4.1.232.22)
+-- cpqRackMibRev Group (1.3.6.1.4.1.232.22.1)
+--
+-- Implementation of the MibRev group is mandatory for all Agents
+-- supporting the Rack Information MIB.
+--
+-- An Agent conforming to this document will return a
+-- cpqRackMibRevMajor of one (1) and a cpqRackMibRevMinor of twenty one (21).
+--
+-- Added trap cpqRackEnclosureManagerLinkDown (22083)
+-- Added trap cpqRackEnclosureManagerLinkUp (22084)
+-- Added group - cpqRackErs in cpqRackComponent
+-- Added trap cpqRackErsCommFailure (22085)
+-- Added trap cpqRackPowerSubsystemOverloadConditionRepaired (22086)
+--
+-- ****************************************************************************
+
+ cpqRackMibRevMajor OBJECT-TYPE
+ SYNTAX INTEGER (1..65535)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The major revision level of the MIB.
+
+ A change in the major revision level represents a major change
+ in the architecture of the MIB. A change in the major revision
+ level may indicate a significant change in the information
+ supported and/or the meaning of the supported information,
+ correct interpretation of data may require a MIB document with
+ the same major revision level."
+ ::= { cpqRackMibRev 1 }
+
+ cpqRackMibRevMinor OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The minor revision level of the MIB.
+
+ A change in the minor revision level may represent some minor
+ additional support, no changes to any pre-existing information
+ has occurred."
+ ::= { cpqRackMibRev 2 }
+
+ cpqRackMibCondition OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1),
+ ok(2), -- default
+ degraded(3),
+ failed(4)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The overall condition.
+
+ This object represents the overall status of the
+ rack information represented by this MIB."
+ ::= { cpqRackMibRev 3 }
+
+-- ****************************************************************************
+-- Rack Information Common
+-- =======================
+--
+-- The compaq enterprise (1.3.6.1.4.1.232)
+-- cpqRackInfo Group (1.3.6.1.4.1.232.22)
+-- cpqRackComponent Group (1.3.6.1.4.1.232.22.2)
+-- cpqRackInterface Group (1.3.6.1.4.1.232.22.2.1)
+-- cpqRackOsCommon Group (1.3.6.1.4.1.232.22.2.1.4)
+--
+--
+-- Implementation of the cpqRackOsCommon group is mandatory for all
+-- Agents that support the Rack Information MIB.
+--
+-- ****************************************************************************
+
+ cpqRackOsCommonPollFreq OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The Management Agent's polling frequency.
+
+ The frequency, in seconds, at which the Agent requests
+ information from the device driver. A frequency of zero (0)
+ indicates that the Insight Agent retrieves the information upon
+ request of a management station, it does not poll the device
+ driver at a specific interval.
+
+ If the poll frequency is zero (0) all attempts to write to this
+ object will fail. If the poll frequency is non-zero,
+ setting this value will change the polling frequency of the
+ Insight Agent. Setting the poll frequency to zero (0) will
+ always fail, an agent may also choose to fail any request to
+ change the poll frequency to a value that would severely impact
+ system performance."
+ ::= { cpqRackOsCommon 1 }
+
+
+-- ****************************************************************************
+-- Rack Asset Group
+-- ================
+--
+-- The compaq enterprise (1.3.6.1.4.1.232)
+-- cpqRackInfo Group (1.3.6.1.4.1.232.22)
+-- cpqRackComponent Group (1.3.6.1.4.1.232.22.2)
+-- cpqRackAsset Group (1.3.6.1.4.1.232.22.2.2)
+--
+-- The cpqRackAsset group contains the serial numbers, names, etc. of any
+-- Rack hardware that supports asset management.
+--
+-- Implementation of the cpqRackAsset group is mandatory for all
+-- Agents that support the Rack Information MIB.
+--
+-- ****************************************************************************
+
+-- ****************************************************************************
+-- Rack Asset Table
+-- ================
+--
+-- The compaq enterprise (1.3.6.1.4.1.232)
+-- cpqRackInfo Group (1.3.6.1.4.1.232.22)
+-- cpqRackComponent Group (1.3.6.1.4.1.232.22.2)
+-- cpqRackAsset Group (1.3.6.1.4.1.232.22.2.2)
+-- cpqRackAssetTable (1.3.6.1.4.1.232.22.2.2.1)
+--
+-- ****************************************************************************
+
+ cpqRackAssetTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CpqRackAssetEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A table of rack asset information."
+ ::= { cpqRackAsset 1 }
+
+ cpqRackAssetEntry OBJECT-TYPE
+ SYNTAX CpqRackAssetEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A rack asset description."
+ INDEX { cpqRackAssetIndex }
+ ::= { cpqRackAssetTable 1 }
+
+ CpqRackAssetEntry ::= SEQUENCE {
+ cpqRackAssetIndex INTEGER,
+ cpqRackName DisplayString,
+ cpqRackUid DisplayString,
+ cpqRackSerialNum DisplayString,
+ cpqRackTrapSequenceNum INTEGER,
+ cpqRackHeight INTEGER,
+ cpqRackWidth INTEGER,
+ cpqRackDepth INTEGER
+ }
+
+ cpqRackAssetIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A number that uniquely specifies this rack table entry."
+ ::= { cpqRackAssetEntry 1 }
+
+ cpqRackName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The customer changeable identifier used to identify the entire
+ rack.
+
+ The string will be empty if the system does not report this
+ function."
+ ::= { cpqRackAssetEntry 2 }
+
+ cpqRackUid OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The rack unique identifier.
+
+ The string will be empty if the rack does not report the
+ UID or if it could not be determined."
+ ::= { cpqRackAssetEntry 3 }
+
+ cpqRackSerialNum OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The rack serial number.
+
+ The string will be empty if the rack does not report the
+ serial number."
+ ::= { cpqRackAssetEntry 4 }
+
+ cpqRackTrapSequenceNum OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The trap sequence number for rack traps.
+
+ This is used by the management application trap processing.
+
+ This will be -1 if the rack does not report the information or
+ it could not be determined."
+ ::= { cpqRackAssetEntry 5 }
+
+ cpqRackHeight OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The internal height dimension of the useable rack space expressed
+ in millimeters.
+
+ This will be -1 if the rack does not report the information or
+ it could not be determined."
+ ::= { cpqRackAssetEntry 6 }
+
+ cpqRackWidth OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The internal width dimension of the useable rack space expressed
+ in millimeters.
+
+ This will be -1 if the rack does not report the information or
+ it could not be determined."
+ ::= { cpqRackAssetEntry 7 }
+
+ cpqRackDepth OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The internal depth dimension of the useable rack space expressed
+ in millimeters.
+
+ This will be -1 if the rack does not report the information or
+ it could not be determined."
+ ::= { cpqRackAssetEntry 8 }
+
+
+-- ****************************************************************************
+-- Rack Enclosure Chassis Group
+-- ============================
+--
+-- The compaq enterprise (1.3.6.1.4.1.232)
+-- cpqRackInfo Group (1.3.6.1.4.1.232.22)
+-- cpqRackComponent Group (1.3.6.1.4.1.232.22.2)
+-- cpqRackEnclosure Group (1.3.6.1.4.1.232.22.2.3)
+--
+-- The cpqRackEnclosure group contains the information about rack
+-- enclosures.
+--
+-- ****************************************************************************
+
+-- ****************************************************************************
+-- Rack Common Enclosure Table
+-- ===========================
+--
+-- The compaq enterprise (1.3.6.1.4.1.232)
+-- cpqRackInfo Group (1.3.6.1.4.1.232.22)
+-- cpqRackComponent Group (1.3.6.1.4.1.232.22.2)
+-- cpqRackEnclosure Group (1.3.6.1.4.1.232.22.2.3)
+-- cpqRackCommonEnclosure Group (1.3.6.1.4.1.232.22.2.3.1)
+-- cpqRackCommonEnclosureTable (1.3.6.1.4.1.232.22.2.3.1.1)
+--
+-- ****************************************************************************
+
+ cpqRackCommonEnclosureTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CpqRackCommonEnclosureEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A table of rack enclosure information."
+ ::= { cpqRackCommonEnclosure 1 }
+
+ cpqRackCommonEnclosureEntry OBJECT-TYPE
+ SYNTAX CpqRackCommonEnclosureEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A rack enclosure description."
+ INDEX { cpqRackCommonEnclosureRack,
+ cpqRackCommonEnclosureIndex }
+ ::= { cpqRackCommonEnclosureTable 1 }
+
+ CpqRackCommonEnclosureEntry ::= SEQUENCE {
+ cpqRackCommonEnclosureRack INTEGER,
+ cpqRackCommonEnclosureIndex INTEGER,
+ cpqRackCommonEnclosureModel DisplayString,
+ cpqRackCommonEnclosureAssetTag DisplayString,
+ cpqRackCommonEnclosurePartNumber DisplayString,
+ cpqRackCommonEnclosureSparePartNumber DisplayString,
+ cpqRackCommonEnclosureSerialNum DisplayString,
+ cpqRackCommonEnclosureFWRev DisplayString,
+ cpqRackCommonEnclosureName DisplayString,
+ cpqRackCommonEnclosureNeighborNamePrev DisplayString,
+ cpqRackCommonEnclosureNeighborNameNext DisplayString,
+ cpqRackCommonEnclosureHeight INTEGER,
+ cpqRackCommonEnclosureWidth INTEGER,
+ cpqRackCommonEnclosureDepth INTEGER,
+ cpqRackCommonEnclosureTrapSequenceNum INTEGER,
+ cpqRackCommonEnclosureCondition INTEGER,
+ cpqRackCommonEnclosureHasServerBlades INTEGER,
+ cpqRackCommonEnclosureHasPowerSupplies INTEGER,
+ cpqRackCommonEnclosureHasNetConnectors INTEGER,
+ cpqRackCommonEnclosureHasTempSensors INTEGER,
+ cpqRackCommonEnclosureHasFans INTEGER,
+ cpqRackCommonEnclosureHasFuses INTEGER,
+ cpqRackCommonEnclosureMgmtUID INTEGER,
+ cpqRackCommonEnclosureSerialNumPrev DisplayString,
+ cpqRackCommonEnclosureSerialNumNext DisplayString,
+ cpqRackCommonEnclosureAddress INTEGER,
+ cpqRackCommonEnclosureProductId DisplayString,
+ cpqRackCommonEnclosureProductIdPrev DisplayString,
+ cpqRackCommonEnclosureProductIdNext DisplayString,
+ cpqRackCommonEnclosureUUID DisplayString,
+ cpqRackCommonEnclosureUUIDPrev DisplayString,
+ cpqRackCommonEnclosureUUIDNext DisplayString,
+ cpqRackCommonEnclosureHasManagers INTEGER
+ }
+
+ cpqRackCommonEnclosureRack OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A number that uniquely specifies this rack."
+ ::= { cpqRackCommonEnclosureEntry 1 }
+
+ cpqRackCommonEnclosureIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A number that uniquely specifies this enclosure in the rack."
+ ::= { cpqRackCommonEnclosureEntry 2 }
+
+ cpqRackCommonEnclosureModel OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The model name of the enclosure.
+
+ The string will be empty if the enclosure does not report the
+ model information."
+ ::= { cpqRackCommonEnclosureEntry 3 }
+
+ cpqRackCommonEnclosureAssetTag OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The customer changeable asset identifier of the enclosure.
+
+ The string will be empty if the system does not report this
+ function or if the asset tag has not been set."
+ ::= { cpqRackCommonEnclosureEntry 4 }
+
+ cpqRackCommonEnclosurePartNumber OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The part number of the enclosure.
+
+ The string will be empty if the enclosure does not report this
+ function."
+ ::= { cpqRackCommonEnclosureEntry 5 }
+
+ cpqRackCommonEnclosureSparePartNumber OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The spare part number of the enclosure.
+
+ The string will be empty if the enclosure does not report this
+ function."
+ ::= { cpqRackCommonEnclosureEntry 6 }
+
+ cpqRackCommonEnclosureSerialNum OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The serial number of the enclosure.
+
+ The string will be empty if the enclosure does not report the
+ serial number."
+ ::= { cpqRackCommonEnclosureEntry 7 }
+
+ cpqRackCommonEnclosureFWRev OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The firmware revision of the enclosure.
+
+ The string will be empty if the enclosure does not report the
+ firmware revision or does not contain firmware."
+ ::= { cpqRackCommonEnclosureEntry 8 }
+
+ cpqRackCommonEnclosureName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the enclosure.
+
+ The string will be empty if the enclosure does not report the
+ name or it could not be determined."
+ ::= { cpqRackCommonEnclosureEntry 9 }
+
+ cpqRackCommonEnclosureNeighborNamePrev OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the enclosure immediately preceding or above this
+ enclosure.
+
+ The string will be empty if the neighbor enclosure name could not be
+ determined or there is no enclosure preceding this one."
+ ::= { cpqRackCommonEnclosureEntry 10 }
+
+ cpqRackCommonEnclosureNeighborNameNext OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the enclosure immediately following or below this
+ enclosure.
+
+ The string will be empty if the neighbor enclosure name could not be
+ determined or there is no enclosure following this one."
+ ::= { cpqRackCommonEnclosureEntry 11 }
+
+ cpqRackCommonEnclosureHeight OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The height dimension of the rack space taken by the
+ enclosure expressed in millimeters.
+
+ This will be -1 if the rack does not report the information or
+ it could not be determined."
+ ::= { cpqRackCommonEnclosureEntry 12 }
+
+ cpqRackCommonEnclosureWidth OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The width dimension of the rack space taken by the
+ enclosure expressed in millimeters.
+
+ This will be -1 if the rack does not report the information or
+ it could not be determined."
+ ::= { cpqRackCommonEnclosureEntry 13 }
+
+ cpqRackCommonEnclosureDepth OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The depth dimension of the rack space taken by the
+ enclosure expressed in millimeters.
+
+ This will be -1 if the rack does not report the information or
+ it could not be determined."
+ ::= { cpqRackCommonEnclosureEntry 14 }
+
+ cpqRackCommonEnclosureTrapSequenceNum OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The trap sequence number for the enclosure.
+
+ This is used by the management application trap processing.
+
+ This will be -1 if the rack does not report the information or
+ it could not be determined."
+ ::= { cpqRackCommonEnclosureEntry 15 }
+
+ cpqRackCommonEnclosureCondition OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1),
+ ok(2),
+ degraded(3),
+ failed(4)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The overall condition of the enclosure.
+
+ This is the aggregate of the temperature sensors, fans, and
+ fuses within the enclosure.
+
+ This value will be one of the following:
+
+ other(1)
+ No temperature sensors, fans, or fuses in the enclosure or the
+ state could no be determined.
+
+ ok(2)
+ All temperature sensors, fans, and fuses are within the normal
+ operating range.
+
+ degraded(3)
+ One or more temperature sensors, fans, or fuses are outside of
+ the normal operating range. None are failed.
+
+ failed(4)
+ The temperature sensor exceeded the critical threshold value,
+ a required fan has failed, or a fuse has been tripped.
+
+ The system will automatically shutdown if the failed(4) condition
+ results, so it is unlikely that this value will ever be returned
+ by the agent."
+ ::= { cpqRackCommonEnclosureEntry 16 }
+
+ cpqRackCommonEnclosureHasServerBlades OBJECT-TYPE
+ SYNTAX INTEGER {
+ false(1),
+ true(2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The enclosure can contain server blades.
+
+ This will be true(2) is the enclosure can house server blades. The
+ cpqRackServerEnclosureTable will contain server enclosure specific
+ information.
+
+ Match the cpqRackCommonEnclosureSerialNum in this table to the
+ serial number in the cpqRackServerEnclosureTable to get complete
+ information on the server enclosure."
+ ::= { cpqRackCommonEnclosureEntry 17 }
+
+ cpqRackCommonEnclosureHasPowerSupplies OBJECT-TYPE
+ SYNTAX INTEGER {
+ false(1),
+ true(2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The enclosure can contain power supplies.
+
+ This will be true(2) is the enclosure can house power supplies. The
+ cpqRackEnclosurePowerTable will contain power enclosure specific
+ information.
+
+ Match the cpqRackCommonEnclosureSerialNum in this table to the
+ serial number in the cpqRackEnclosurePowerTable to get complete
+ information on the power enclosure."
+ ::= { cpqRackCommonEnclosureEntry 18 }
+
+ cpqRackCommonEnclosureHasNetConnectors OBJECT-TYPE
+ SYNTAX INTEGER {
+ false(1),
+ true(2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The enclosure contains network connectivity.
+
+ This will be true(2) is the enclosure contains network connectivity.
+ The cpqRackCommonEnclosureNetConnectorTable will contain network
+ connectivity specific information.
+
+ Match the cpqRackCommonEnclosureSerialNum in this table to the
+ serial number in the cpqRackCommonEnclosureNetConnectorTable to get complete
+ information on the network connector enclosure."
+ ::= { cpqRackCommonEnclosureEntry 19 }
+
+ cpqRackCommonEnclosureHasTempSensors OBJECT-TYPE
+ SYNTAX INTEGER {
+ false(1),
+ true(2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The enclosure contains temperature sensors.
+
+ This will be true(2) is the enclosure contains
+ temperature sensors. The cpqRackCommonEnclosureTempTable will
+ contain temperature sensor specific information.
+
+ Match the cpqRackCommonEnclosureSerialNum in this table to the
+ serial number in the cpqRackCommonEnclosureTempTable to get complete
+ information on the enclosure."
+ ::= { cpqRackCommonEnclosureEntry 20 }
+
+ cpqRackCommonEnclosureHasFans OBJECT-TYPE
+ SYNTAX INTEGER {
+ false(1),
+ true(2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The enclosure contains fans.
+
+ This will be true(2) is the enclosure contains fans.
+ The cpqRackCommonEnclosureFanTable will contain the fan
+ specific information.
+
+ Match the cpqRackCommonEnclosureSerialNum in this table to the
+ serial number in the cpqRackCommonEnclosureFanTable to get complete
+ information on the enclosure."
+ ::= { cpqRackCommonEnclosureEntry 21 }
+
+ cpqRackCommonEnclosureHasFuses OBJECT-TYPE
+ SYNTAX INTEGER {
+ false(1),
+ true(2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The enclosure contains fuses.
+
+ This will be true(2) is the enclosure contains fuses.
+ The cpqRackCommonEnclosureFuseTable will contain the fuse
+ specific information.
+
+ Match the cpqRackCommonEnclosureSerialNum in this table to the
+ serial number in the cpqRackCommonEnclosureFuseTable to get complete
+ information on the enclosure."
+ ::= { cpqRackCommonEnclosureEntry 22 }
+
+ cpqRackCommonEnclosureMgmtUID OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1), -- Unknown device or could not be determined
+ none(2), -- No Unit Identifier LED present
+ ledOn(3), -- Unit Identifier LED is On
+ ledOff(4) -- Unit Identifier LED is Off
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The Unit Identifier LED.
+
+ This value will be one of the following:
+
+ other(1)
+ The state of the LED could not be determined. Setting the
+ LED state is not allowed.
+
+ none(2)
+ The LED is not present. Setting LED state is not allowed.
+
+ ledOn(3)
+ The LED is present and ON. The LED can be turned off
+ by setting the cpqRackCommonEnclosureMgmtUID to ledOff(4).
+
+ ledOff(4)
+ The LED is present and OFF. The LED can be turned on
+ by setting the cpqRackCommonEnclosureMgmtUID to ledOn(3)."
+ ::= { cpqRackCommonEnclosureEntry 23 }
+
+ cpqRackCommonEnclosureSerialNumPrev OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The serial number of the enclosure immediately preceding or
+ above this enclosure.
+
+ The string will be empty if the neighbor enclosure serial number
+ could not be determined or there is no enclosure preceding this one."
+ ::= { cpqRackCommonEnclosureEntry 24 }
+
+ cpqRackCommonEnclosureSerialNumNext OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The serial number of the enclosure immediately following or
+ below this enclosure.
+
+ The string will be empty if the neighbor enclosure serial number
+ could not be determined or there is no enclosure following this one."
+ ::= { cpqRackCommonEnclosureEntry 25 }
+
+ cpqRackCommonEnclosureAddress OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The unique address of the enclosure within the rack.
+
+ This will be -1 if the rack does not report the information or
+ it could not be determined."
+ ::= { cpqRackCommonEnclosureEntry 26 }
+
+ cpqRackCommonEnclosureProductId OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The product id string of the enclosure.
+
+ The string will be empty if the enclosure does not report the
+ product id string."
+ ::= { cpqRackCommonEnclosureEntry 27 }
+
+ cpqRackCommonEnclosureProductIdPrev OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The product id string of the enclosure immediately preceding or
+ above this enclosure.
+
+ The string will be empty if the enclosure does not report the
+ product id string."
+ ::= { cpqRackCommonEnclosureEntry 28 }
+
+ cpqRackCommonEnclosureProductIdNext OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The product id string of the enclosure immediately following or
+ below this enclosure.
+
+ The string will be empty if the enclosure does not report the
+ product id string."
+ ::= { cpqRackCommonEnclosureEntry 29 }
+
+ cpqRackCommonEnclosureUUID OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The universal unique identifier string of the enclosure.
+
+ The string will be empty if the enclosure does not report the
+ UUID string."
+ ::= { cpqRackCommonEnclosureEntry 30 }
+
+ cpqRackCommonEnclosureUUIDPrev OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The universal unique identifier string of the enclosure
+ immediately preceding or above this enclosure.
+
+ The string will be empty if the enclosure does not report the
+ UUID string or if there is no preceding enclosure."
+ ::= { cpqRackCommonEnclosureEntry 31 }
+
+ cpqRackCommonEnclosureUUIDNext OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The universal unique identifier string of the enclosure
+ immediately following or below this enclosure.
+
+ The string will be empty if the enclosure does not report the
+ UUID string or if there is no following enclosure."
+ ::= { cpqRackCommonEnclosureEntry 32 }
+
+ cpqRackCommonEnclosureHasManagers OBJECT-TYPE
+ SYNTAX INTEGER {
+ false(1),
+ true(2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The enclosure contains managers.
+
+ This will be true(2) is the enclosure contains managers.
+ The cpqRackCommonEnclosureManagerTable will contain the manager
+ specific information.
+
+ Match the cpqRackCommonEnclosureSerialNum in this table to the
+ serial number in the cpqRackCommonEnclosureManagerTable to get
+ complete information on the enclosure."
+ ::= { cpqRackCommonEnclosureEntry 33 }
+
+
+-- ****************************************************************************
+-- Rack Enclosure Common Temperature Sensor Table
+-- ==============================================
+--
+-- The compaq enterprise (1.3.6.1.4.1.232)
+-- cpqRackInfo Group (1.3.6.1.4.1.232.22)
+-- cpqRackComponent Group (1.3.6.1.4.1.232.22.2)
+-- cpqRackEnclosure Group (1.3.6.1.4.1.232.22.2.3)
+-- cpqRackCommonEnclosure Group (1.3.6.1.4.1.232.22.2.3.1)
+-- cpqRackCommonEnclosureTempTable (1.3.6.1.4.1.232.22.2.3.1.2)
+--
+-- ****************************************************************************
+
+ cpqRackCommonEnclosureTempTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CpqRackCommonEnclosureTempEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A table of rack enclosure temperature sensor information."
+ ::= { cpqRackCommonEnclosure 2 }
+
+ cpqRackCommonEnclosureTempEntry OBJECT-TYPE
+ SYNTAX CpqRackCommonEnclosureTempEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A rack enclosure temperature sensor description."
+ INDEX { cpqRackCommonEnclosureTempRack,
+ cpqRackCommonEnclosureTempChassis,
+ cpqRackCommonEnclosureTempSensorIndex }
+ ::= { cpqRackCommonEnclosureTempTable 1 }
+
+ CpqRackCommonEnclosureTempEntry ::= SEQUENCE {
+ cpqRackCommonEnclosureTempRack INTEGER,
+ cpqRackCommonEnclosureTempChassis INTEGER,
+ cpqRackCommonEnclosureTempSensorIndex INTEGER,
+ cpqRackCommonEnclosureTempSensorEnclosureName DisplayString,
+ cpqRackCommonEnclosureTempLocation DisplayString,
+ cpqRackCommonEnclosureTempCurrent INTEGER,
+ cpqRackCommonEnclosureTempThreshold INTEGER,
+ cpqRackCommonEnclosureTempCondition INTEGER,
+ cpqRackCommonEnclosureTempType INTEGER,
+ cpqRackCommonEnclosureTempSensorEnclosureSerialNum DisplayString
+ }
+
+ cpqRackCommonEnclosureTempRack OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A number that uniquely specifies this rack."
+ ::= { cpqRackCommonEnclosureTempEntry 1 }
+
+ cpqRackCommonEnclosureTempChassis OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A number that uniquely specifies this enclosure in the rack."
+ ::= { cpqRackCommonEnclosureTempEntry 2 }
+
+ cpqRackCommonEnclosureTempSensorIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A number that uniquely specifies this temperature sensor within
+ this enclosure in the rack."
+ ::= { cpqRackCommonEnclosureTempEntry 3 }
+
+ cpqRackCommonEnclosureTempSensorEnclosureName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the enclosure.
+
+ The string will be empty if the enclosure does not report the
+ name or it could not be determined."
+ ::= { cpqRackCommonEnclosureTempEntry 4 }
+
+ cpqRackCommonEnclosureTempLocation OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The location description of the temperature sensor within the
+ enclosure.
+
+ The string will be empty if the location could not be
+ determined."
+ ::= { cpqRackCommonEnclosureTempEntry 5 }
+
+ cpqRackCommonEnclosureTempCurrent OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This is the current temperature sensor reading in degrees
+ celsius.
+
+ If this value cannot be determined by software, then a value
+ of -1 will be returned."
+ ::= { cpqRackCommonEnclosureTempEntry 6 }
+
+ cpqRackCommonEnclosureTempThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This is the threshold temperature sensor setting
+ in degrees celsius. This is the temperature in which the
+ sensor will be considered to be in a tripped state this
+ causing some action to occur depending on the type of
+ the sensor. The action of temperature sensor threshold
+ will be indicated by the cpqRackCommonEnclosureTempType
+ item. If the type is blowout(5), then the temperature sensor
+ will cause the fans to speed up. If the type is caution(9),
+ then the temperature sensor is in a degraded state. If the
+ type is critical(15), then the enclosure will be considered
+ as in a failed state.
+
+ If this value cannot be determined by software, then a value
+ of -1 will be returned."
+ ::= { cpqRackCommonEnclosureTempEntry 7 }
+
+ cpqRackCommonEnclosureTempCondition OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1),
+ ok(2),
+ degraded(3),
+ failed(4)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The Temperature sensor condition.
+
+ This value will be one of the following:
+
+ other(1)
+ Temperature could not be determined.
+
+ ok(2)
+ The temperature sensor is within the normal operating range.
+
+ degraded(3)
+ The temperature sensor is outside of the normal operating range.
+
+ failed(4)
+ The temperature sensor detects a condition that could
+ possibly damage the system.
+
+ The system will automatically shutdown if the failed(4) condition
+ results, so it is unlikely that this value will ever be returned
+ by the agent."
+ ::= { cpqRackCommonEnclosureTempEntry 8 }
+
+ cpqRackCommonEnclosureTempType OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1),
+ blowout(5),
+ caution(9),
+ critical(15)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This specifies the type of this instance of temperature
+ sensor.
+
+ This value will be one of the following:
+
+ other(1)
+ Temperature threshold type could not be determined.
+
+ blowout(5)
+ If a blowout(5) temperature sensor reaches its threshold,
+ the fan or fans in the area of the temperature sensor will
+ increase in speed in an attempt to reduce the temperature
+ before a caution or critical threshold is reached.
+
+ caution(9)
+ If a caution(9) temperature sensor reaches its threshold, the
+ cpqRackCommonEnclosureTempCondition will be set to degraded(3)
+ and the system will either continue or shutdown depending
+ on the user preferences.
+
+ critical(15)
+ If a critical(15) temperature sensor reaches its threshold,
+ the cpqHeTemperatureCondition will be set to failed(4)
+ and the system will shutdown."
+ ::= { cpqRackCommonEnclosureTempEntry 9 }
+
+ cpqRackCommonEnclosureTempSensorEnclosureSerialNum OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The serial number of the enclosure containing this temperature
+ sensor.
+
+ The string will be empty if the enclosure does not report the
+ serial number or it could not be determined."
+ ::= { cpqRackCommonEnclosureTempEntry 10 }
+
+
+-- ****************************************************************************
+-- Rack Enclosure Common Fan Table
+-- ===============================
+--
+-- The compaq enterprise (1.3.6.1.4.1.232)
+-- cpqRackInfo Group (1.3.6.1.4.1.232.22)
+-- cpqRackComponent Group (1.3.6.1.4.1.232.22.2)
+-- cpqRackEnclosure Group (1.3.6.1.4.1.232.22.2.3)
+-- cpqRackCommonEnclosure Group (1.3.6.1.4.1.232.22.2.3.1)
+-- cpqRackCommonEnclosureFanTable (1.3.6.1.4.1.232.22.2.3.1.3)
+--
+-- ****************************************************************************
+
+ cpqRackCommonEnclosureFanTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CpqRackCommonEnclosureFanEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A table of rack enclosure fan information."
+ ::= { cpqRackCommonEnclosure 3 }
+
+ cpqRackCommonEnclosureFanEntry OBJECT-TYPE
+ SYNTAX CpqRackCommonEnclosureFanEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A rack enclosure fan description."
+ INDEX { cpqRackCommonEnclosureFanRack,
+ cpqRackCommonEnclosureFanChassis,
+ cpqRackCommonEnclosureFanIndex }
+ ::= { cpqRackCommonEnclosureFanTable 1 }
+
+ CpqRackCommonEnclosureFanEntry ::= SEQUENCE {
+ cpqRackCommonEnclosureFanRack INTEGER,
+ cpqRackCommonEnclosureFanChassis INTEGER,
+ cpqRackCommonEnclosureFanIndex INTEGER,
+ cpqRackCommonEnclosureFanEnclosureName DisplayString,
+ cpqRackCommonEnclosureFanLocation DisplayString,
+ cpqRackCommonEnclosureFanPartNumber DisplayString,
+ cpqRackCommonEnclosureFanSparePartNumber DisplayString,
+ cpqRackCommonEnclosureFanPresent INTEGER,
+ cpqRackCommonEnclosureFanRedundant INTEGER,
+ cpqRackCommonEnclosureFanRedundantGroupId INTEGER,
+ cpqRackCommonEnclosureFanCondition INTEGER,
+ cpqRackCommonEnclosureFanEnclosureSerialNum DisplayString
+ }
+
+ cpqRackCommonEnclosureFanRack OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A number that uniquely specifies this rack."
+ ::= { cpqRackCommonEnclosureFanEntry 1 }
+
+ cpqRackCommonEnclosureFanChassis OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A number that uniquely specifies this enclosure in the rack."
+ ::= { cpqRackCommonEnclosureFanEntry 2 }
+
+ cpqRackCommonEnclosureFanIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A number that uniquely specifies this fan within this
+ enclosure in the rack."
+ ::= { cpqRackCommonEnclosureFanEntry 3 }
+
+ cpqRackCommonEnclosureFanEnclosureName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the enclosure.
+
+ The string will be empty if the enclosure does not report the
+ name or it could not be determined."
+ ::= { cpqRackCommonEnclosureFanEntry 4 }
+
+ cpqRackCommonEnclosureFanLocation OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The location description of the fan within the enclosure.
+
+ The string will be empty if the location could not be
+ determined."
+ ::= { cpqRackCommonEnclosureFanEntry 5 }
+
+ cpqRackCommonEnclosureFanPartNumber OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The part number of the enclosure fan.
+
+ The string will be empty if the part number could not be
+ determined."
+ ::= { cpqRackCommonEnclosureFanEntry 6 }
+
+ cpqRackCommonEnclosureFanSparePartNumber OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The spare part number of the enclosure fan.
+
+ The string will be empty if the part number could not be
+ determined."
+ ::= { cpqRackCommonEnclosureFanEntry 7 }
+
+ cpqRackCommonEnclosureFanPresent OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1),
+ absent(2),
+ present(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This specifies if the fan described is present in the system."
+ ::= { cpqRackCommonEnclosureFanEntry 8 }
+
+ cpqRackCommonEnclosureFanRedundant OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1),
+ notRedundant(2),
+ redundant(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This specifies if the fan is in a redundant configuration."
+ ::= { cpqRackCommonEnclosureFanEntry 9 }
+
+ cpqRackCommonEnclosureFanRedundantGroupId OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This specifies the group number for redundant fans within this
+ enclosure."
+ ::= { cpqRackCommonEnclosureFanEntry 10 }
+
+ cpqRackCommonEnclosureFanCondition OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1),
+ ok(2),
+ degraded(3),
+ failed(4)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The condition of the fan.
+
+ This value will be one of the following:
+
+ other(1)
+ Fan status detection is not supported.
+
+ ok(2)
+ The fan is operating properly.
+
+ degraded(2)
+ A redundant fan is not operating properly.
+
+ failed(4)
+ A non-redundant fan is not operating properly."
+ ::= { cpqRackCommonEnclosureFanEntry 11 }
+
+ cpqRackCommonEnclosureFanEnclosureSerialNum OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The serial number of the enclosure containing the fan.
+
+ The string will be empty if the enclosure does not report the
+ serial number or it could not be determined."
+ ::= { cpqRackCommonEnclosureFanEntry 12 }
+
+-- ****************************************************************************
+-- Rack Enclosure Common Fuse Table
+-- ================================
+--
+-- The compaq enterprise (1.3.6.1.4.1.232)
+-- cpqRackInfo Group (1.3.6.1.4.1.232.22)
+-- cpqRackComponent Group (1.3.6.1.4.1.232.22.2)
+-- cpqRackEnclosure Group (1.3.6.1.4.1.232.22.2.3)
+-- cpqRackCommonEnclosure Group (1.3.6.1.4.1.232.22.2.3.1)
+-- cpqRackCommonEnclosureFuseTable (1.3.6.1.4.1.232.22.2.3.1.4)
+--
+-- ****************************************************************************
+
+ cpqRackCommonEnclosureFuseTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CpqRackCommonEnclosureFuseEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A table of rack enclosure fuse information."
+ ::= { cpqRackCommonEnclosure 4 }
+
+ cpqRackCommonEnclosureFuseEntry OBJECT-TYPE
+ SYNTAX CpqRackCommonEnclosureFuseEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A rack enclosure fuse description."
+ INDEX { cpqRackCommonEnclosureFuseRack,
+ cpqRackCommonEnclosureFuseChassis,
+ cpqRackCommonEnclosureFuseIndex }
+ ::= { cpqRackCommonEnclosureFuseTable 1 }
+
+ CpqRackCommonEnclosureFuseEntry ::= SEQUENCE {
+ cpqRackCommonEnclosureFuseRack INTEGER,
+ cpqRackCommonEnclosureFuseChassis INTEGER,
+ cpqRackCommonEnclosureFuseIndex INTEGER,
+ cpqRackCommonEnclosureFuseEnclosureName DisplayString,
+ cpqRackCommonEnclosureFuseLocation DisplayString,
+ cpqRackCommonEnclosureFusePresent INTEGER,
+ cpqRackCommonEnclosureFuseCondition INTEGER
+ }
+
+ cpqRackCommonEnclosureFuseRack OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A number that uniquely specifies this rack."
+ ::= { cpqRackCommonEnclosureFuseEntry 1 }
+
+ cpqRackCommonEnclosureFuseChassis OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A number that uniquely specifies this enclosure in the rack."
+ ::= { cpqRackCommonEnclosureFuseEntry 2 }
+
+ cpqRackCommonEnclosureFuseIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A number that uniquely specifies the fuse within this enclosure."
+ ::= { cpqRackCommonEnclosureFuseEntry 3 }
+
+ cpqRackCommonEnclosureFuseEnclosureName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the enclosure.
+
+ The string will be empty if the enclosure does not report the
+ name or it could not be determined."
+ ::= { cpqRackCommonEnclosureFuseEntry 4 }
+
+ cpqRackCommonEnclosureFuseLocation OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The location description of the fuse within the enclosure.
+
+ The string will be empty if the location could not be
+ determined."
+ ::= { cpqRackCommonEnclosureFuseEntry 5 }
+
+ cpqRackCommonEnclosureFusePresent OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1),
+ absent(2),
+ present(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This specifies if the fuse described is present in the system."
+ ::= { cpqRackCommonEnclosureFuseEntry 6 }
+
+ cpqRackCommonEnclosureFuseCondition OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1),
+ ok(2),
+ failed(4)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The condition of the fuse.
+
+ This value will be one of the following:
+
+ other(1)
+ Fuse status detection is not supported.
+
+ ok(2)
+ The fuse is operating properly.
+
+ failed(4)
+ A fuse has been tripped or is not operating properly."
+ ::= { cpqRackCommonEnclosureFuseEntry 7 }
+
+-- ****************************************************************************
+-- Rack Enclosure Common FRU Table
+-- ===============================
+--
+-- The compaq enterprise (1.3.6.1.4.1.232)
+-- cpqRackInfo Group (1.3.6.1.4.1.232.22)
+-- cpqRackComponent Group (1.3.6.1.4.1.232.22.2)
+-- cpqRackEnclosure Group (1.3.6.1.4.1.232.22.2.3)
+-- cpqRackCommonEnclosure Group (1.3.6.1.4.1.232.22.2.3.1)
+-- cpqRackCommonEnclosureFruTable (1.3.6.1.4.1.232.22.2.3.1.5)
+--
+-- ****************************************************************************
+
+ cpqRackCommonEnclosureFruTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CpqRackCommonEnclosureFruEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A table of rack enclosure field replaceable units information."
+ ::= { cpqRackCommonEnclosure 5 }
+
+ cpqRackCommonEnclosureFruEntry OBJECT-TYPE
+ SYNTAX CpqRackCommonEnclosureFruEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A rack enclosure field replaceable unit description."
+ INDEX { cpqRackCommonEnclosureFruRack,
+ cpqRackCommonEnclosureFruChassis,
+ cpqRackCommonEnclosureFruIndex }
+ ::= { cpqRackCommonEnclosureFruTable 1 }
+
+ CpqRackCommonEnclosureFruEntry ::= SEQUENCE {
+ cpqRackCommonEnclosureFruRack INTEGER,
+ cpqRackCommonEnclosureFruChassis INTEGER,
+ cpqRackCommonEnclosureFruIndex INTEGER,
+ cpqRackCommonEnclosureFruEnclosureName DisplayString,
+ cpqRackCommonEnclosureFruDescription DisplayString,
+ cpqRackCommonEnclosureFruLocation DisplayString,
+ cpqRackCommonEnclosureFruAssemblyPartNumber DisplayString,
+ cpqRackCommonEnclosureFruSparePartNumber DisplayString,
+ cpqRackCommonEnclosureFruAutoRev DisplayString,
+ cpqRackCommonEnclosureFruSerialNum DisplayString
+ }
+
+ cpqRackCommonEnclosureFruRack OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A number that uniquely specifies this rack."
+ ::= { cpqRackCommonEnclosureFruEntry 1 }
+
+ cpqRackCommonEnclosureFruChassis OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A number that uniquely specifies this enclosure in the rack."
+ ::= { cpqRackCommonEnclosureFruEntry 2 }
+
+ cpqRackCommonEnclosureFruIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A number that uniquely specifies the FRU within this enclosure."
+ ::= { cpqRackCommonEnclosureFruEntry 3 }
+
+ cpqRackCommonEnclosureFruEnclosureName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the enclosure.
+
+ The string will be empty if the enclosure does not report the
+ name or it could not be determined."
+ ::= { cpqRackCommonEnclosureFruEntry 4 }
+
+ cpqRackCommonEnclosureFruDescription OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A description of the FRU component.
+
+ The string will be empty if the enclosure does not report the
+ description information."
+ ::= { cpqRackCommonEnclosureFruEntry 5 }
+
+ cpqRackCommonEnclosureFruLocation OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The location description of the FRU within the enclosure.
+
+ The string will be empty if the location could not be
+ determined."
+ ::= { cpqRackCommonEnclosureFruEntry 6 }
+
+ cpqRackCommonEnclosureFruAssemblyPartNumber OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The assembly part number of the FRU within the enclosure.
+
+ The string will be empty if the enclosure does not report this
+ information."
+ ::= { cpqRackCommonEnclosureFruEntry 7 }
+
+ cpqRackCommonEnclosureFruSparePartNumber OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The spare part number of the FRU within the enclosure.
+
+ The string will be empty if the enclosure does not report this
+ information."
+ ::= { cpqRackCommonEnclosureFruEntry 8 }
+
+ cpqRackCommonEnclosureFruAutoRev OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The auto revision number of the FRU within the enclosure.
+
+ The string will be empty if the enclosure does not report this
+ information."
+ ::= { cpqRackCommonEnclosureFruEntry 9 }
+
+ cpqRackCommonEnclosureFruSerialNum OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The serial number of the FRU within the enclosure.
+
+ The string will be empty if the enclosure does not report the
+ serial number."
+ ::= { cpqRackCommonEnclosureFruEntry 10 }
+
+-- ****************************************************************************
+-- Rack Enclosure Common Manager Table
+-- ===================================
+--
+-- The compaq enterprise (1.3.6.1.4.1.232)
+-- cpqRackInfo Group (1.3.6.1.4.1.232.22)
+-- cpqRackComponent Group (1.3.6.1.4.1.232.22.2)
+-- cpqRackEnclosure Group (1.3.6.1.4.1.232.22.2.3)
+-- cpqRackCommonEnclosure Group (1.3.6.1.4.1.232.22.2.3.1)
+-- cpqRackCommonEnclosureManagerTable (1.3.6.1.4.1.232.22.2.3.1.6)
+--
+-- ****************************************************************************
+
+ cpqRackCommonEnclosureManagerTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CpqRackCommonEnclosureManagerEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A table of rack enclosure manager information."
+ ::= { cpqRackCommonEnclosure 6 }
+
+ cpqRackCommonEnclosureManagerEntry OBJECT-TYPE
+ SYNTAX CpqRackCommonEnclosureManagerEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A rack enclosure manager description."
+ INDEX { cpqRackCommonEnclosureManagerRack,
+ cpqRackCommonEnclosureManagerChassis,
+ cpqRackCommonEnclosureManagerIndex }
+ ::= { cpqRackCommonEnclosureManagerTable 1 }
+
+ CpqRackCommonEnclosureManagerEntry ::= SEQUENCE {
+ cpqRackCommonEnclosureManagerRack INTEGER,
+ cpqRackCommonEnclosureManagerChassis INTEGER,
+ cpqRackCommonEnclosureManagerIndex INTEGER,
+ cpqRackCommonEnclosureManagerEnclosureName DisplayString,
+ cpqRackCommonEnclosureManagerLocation DisplayString,
+ cpqRackCommonEnclosureManagerPartNumber DisplayString,
+ cpqRackCommonEnclosureManagerSparePartNumber DisplayString,
+ cpqRackCommonEnclosureManagerSerialNum DisplayString,
+ cpqRackCommonEnclosureManagerRole INTEGER,
+ cpqRackCommonEnclosureManagerPresent INTEGER,
+ cpqRackCommonEnclosureManagerRedundant INTEGER,
+ cpqRackCommonEnclosureManagerCondition INTEGER,
+ cpqRackCommonEnclosureManagerEnclosureSerialNum DisplayString,
+ cpqRackCommonEnclosureManagerUUID DisplayString,
+ cpqRackCommonEnclosureManagerFWRev DisplayString
+ }
+
+ cpqRackCommonEnclosureManagerRack OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A number that uniquely specifies this rack."
+ ::= { cpqRackCommonEnclosureManagerEntry 1 }
+
+ cpqRackCommonEnclosureManagerChassis OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A number that uniquely specifies this enclosure in the rack."
+ ::= { cpqRackCommonEnclosureManagerEntry 2 }
+
+ cpqRackCommonEnclosureManagerIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A number that uniquely specifies this manager within this
+ enclosure in the rack."
+ ::= { cpqRackCommonEnclosureManagerEntry 3 }
+
+ cpqRackCommonEnclosureManagerEnclosureName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the enclosure.
+
+ The string will be empty if the enclosure does not report the
+ name or it could not be determined."
+ ::= { cpqRackCommonEnclosureManagerEntry 4 }
+
+ cpqRackCommonEnclosureManagerLocation OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The location description of the manager within the enclosure.
+
+ The string will be empty if the location could not be
+ determined."
+ ::= { cpqRackCommonEnclosureManagerEntry 5 }
+
+ cpqRackCommonEnclosureManagerPartNumber OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The part number of the enclosure manager.
+
+ The string will be empty if the part number could not be
+ determined."
+ ::= { cpqRackCommonEnclosureManagerEntry 6 }
+
+ cpqRackCommonEnclosureManagerSparePartNumber OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The spare part number of the enclosure manager.
+
+ The string will be empty if the part number could not be
+ determined."
+ ::= { cpqRackCommonEnclosureManagerEntry 7 }
+
+ cpqRackCommonEnclosureManagerSerialNum OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The serial number of the enclosure manager.
+
+ The string will be empty if the enclosure does not report the
+ serial number or it could not be determined."
+ ::= { cpqRackCommonEnclosureManagerEntry 8 }
+
+ cpqRackCommonEnclosureManagerRole OBJECT-TYPE
+ SYNTAX INTEGER {
+ standby(1),
+ active(2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This specifies the current role of the manager."
+ ::= { cpqRackCommonEnclosureManagerEntry 9 }
+
+ cpqRackCommonEnclosureManagerPresent OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1),
+ absent(2),
+ present(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This specifies if the manager described is present in the system."
+ ::= { cpqRackCommonEnclosureManagerEntry 10 }
+
+ cpqRackCommonEnclosureManagerRedundant OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1),
+ notRedundant(2),
+ redundant(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This specifies if the manager is in a redundant configuration."
+ ::= { cpqRackCommonEnclosureManagerEntry 11 }
+
+ cpqRackCommonEnclosureManagerCondition OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1),
+ ok(2),
+ degraded(3),
+ failed(4)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The condition of the manager.
+
+ This value will be one of the following:
+
+ other(1)
+ Manager status detection is not supported.
+
+ ok(2)
+ The manager is operating properly.
+
+ degraded(2)
+ A redundant manager is not operating properly.
+
+ failed(4)
+ A non-redundant manager is not operating properly."
+ ::= { cpqRackCommonEnclosureManagerEntry 12 }
+
+ cpqRackCommonEnclosureManagerEnclosureSerialNum OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The serial number of the enclosure containing the manager.
+
+ The string will be empty if the enclosure does not report the
+ serial number or it could not be determined."
+ ::= { cpqRackCommonEnclosureManagerEntry 13 }
+
+ cpqRackCommonEnclosureManagerUUID OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The universal unique identifier string of the manager.
+
+ The string will be empty if the enclosure does not report the
+ UUID string."
+ ::= { cpqRackCommonEnclosureManagerEntry 14 }
+
+ cpqRackCommonEnclosureManagerFWRev OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The firmware revision of the enclosure manager.
+
+ The string will be empty if the enclosure does not report the
+ firmware revision or does not contain firmware."
+ ::= { cpqRackCommonEnclosureManagerEntry 15 }
+
+-- ****************************************************************************
+-- Rack Enclosure for Servers Table
+-- ================================
+--
+-- The compaq enterprise (1.3.6.1.4.1.232)
+-- cpqRackInfo Group (1.3.6.1.4.1.232.22)
+-- cpqRackComponent Group (1.3.6.1.4.1.232.22.2)
+-- cpqRackEnclosure Group (1.3.6.1.4.1.232.22.2.3)
+-- cpqRackServerEnclosure Group (1.3.6.1.4.1.232.22.2.3.2)
+-- cpqRackServerEnclosureTable (1.3.6.1.4.1.232.22.2.3.2.1)
+--
+-- ****************************************************************************
+
+ cpqRackServerEnclosureTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CpqRackServerEnclosureEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A table of rack enclosure information for servers."
+ ::= { cpqRackServerEnclosure 1 }
+
+ cpqRackServerEnclosureEntry OBJECT-TYPE
+ SYNTAX CpqRackServerEnclosureEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A server enclosure description."
+ INDEX { cpqRackServerEnclosureRack,
+ cpqRackServerEnclosureIndex }
+ ::= { cpqRackServerEnclosureTable 1 }
+
+ CpqRackServerEnclosureEntry ::= SEQUENCE {
+ cpqRackServerEnclosureRack INTEGER,
+ cpqRackServerEnclosureIndex INTEGER,
+ cpqRackServerEnclosureName DisplayString,
+ cpqRackServerEnclosureMaxNumBlades INTEGER,
+ cpqRackServerEnclosureMaxNumBladesX INTEGER,
+ cpqRackServerEnclosureMaxNumBladesY INTEGER,
+ cpqRackServerEnclosureSolutionsId OCTET STRING
+ }
+
+ cpqRackServerEnclosureRack OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A number that uniquely specifies this rack."
+ ::= { cpqRackServerEnclosureEntry 1 }
+
+ cpqRackServerEnclosureIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A number that uniquely specifies this server enclosure in the rack."
+ ::= { cpqRackServerEnclosureEntry 2 }
+
+ cpqRackServerEnclosureName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the server enclosure.
+
+ The string will be empty if the enclosure does not report the
+ name or it could not be determined."
+ ::= { cpqRackServerEnclosureEntry 3 }
+
+ cpqRackServerEnclosureMaxNumBlades OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The maximum number of server blades the enclosure can contain.
+
+ The string will be empty if the enclosure does not report the
+ name or it could not be determined."
+ ::= { cpqRackServerEnclosureEntry 4 }
+
+ cpqRackServerEnclosureMaxNumBladesX OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The maximum number of server blades in x-direction (from left to right)
+ the enclosure can contain."
+
+ ::= { cpqRackServerEnclosureEntry 5 }
+
+ cpqRackServerEnclosureMaxNumBladesY OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The maximum number of server blades in y-direction (from top to bottom)
+ the enclosure can contain."
+
+ ::= { cpqRackServerEnclosureEntry 6 }
+
+ cpqRackServerEnclosureSolutionsId OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (8))
+ ACCESS read-write
+ STATUS optional
+ DESCRIPTION
+ "The identifier is used to label enclosure as a BladeSystem Matrix enclosure.
+ Octet Values
+ ===== ==============================
+ 1 Solutions platform identifier
+ Bits[7:4]
+ - 0001b BladeSystem Matrix configured
+ - 0000b reserved
+ Bits[3:0]
+ - 0000b reserved
+ 2 major number
+ - 0x01 - 0xff
+ 3 minor number
+ - 0x01 - 0xff
+ 4 update number
+ - 0x01 - 0xff
+ 5 reserved/unused
+
+ The identifier is set to all 0's if the enclosure is
+ not configured as a BladeSystem Matrix enclosure."
+
+ ::= { cpqRackServerEnclosureEntry 7 }
+
+
+-- ****************************************************************************
+-- Rack Enclosure for Power Supplies Table
+-- =======================================
+--
+-- The compaq enterprise (1.3.6.1.4.1.232)
+-- cpqRackInfo Group (1.3.6.1.4.1.232.22)
+-- cpqRackComponent Group (1.3.6.1.4.1.232.22.2)
+-- cpqRackEnclosure Group (1.3.6.1.4.1.232.22.2.3)
+-- cpqRackPowerEnclosure Group (1.3.6.1.4.1.232.22.2.3.3)
+-- cpqRackPowerEnclosureTable (1.3.6.1.4.1.232.22.2.3.3.1)
+--
+-- ****************************************************************************
+
+ cpqRackPowerEnclosureTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CpqRackPowerEnclosureEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A table of rack power enclosure information."
+ ::= { cpqRackPowerEnclosure 1 }
+
+ cpqRackPowerEnclosureEntry OBJECT-TYPE
+ SYNTAX CpqRackPowerEnclosureEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A rack power enclosure description."
+ INDEX { cpqRackPowerEnclosureRack,
+ cpqRackPowerEnclosureIndex }
+ ::= { cpqRackPowerEnclosureTable 1 }
+
+ CpqRackPowerEnclosureEntry ::= SEQUENCE {
+ cpqRackPowerEnclosureRack INTEGER,
+ cpqRackPowerEnclosureIndex INTEGER,
+ cpqRackPowerEnclosureName DisplayString,
+ cpqRackPowerEnclosureMgmtBoardSerialNum DisplayString,
+ cpqRackPowerEnclosureRedundant INTEGER,
+ cpqRackPowerEnclosureLoadBalanced INTEGER,
+ cpqRackPowerEnclosureInputPwrType INTEGER,
+ cpqRackPowerEnclosurePwrFeedMax INTEGER,
+ cpqRackPowerEnclosureCondition INTEGER,
+ cpqRackPowerEnclosureBladeAutopoweron INTEGER
+ }
+
+ cpqRackPowerEnclosureRack OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A number that uniquely specifies this rack."
+ ::= { cpqRackPowerEnclosureEntry 1 }
+
+ cpqRackPowerEnclosureIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A number that uniquely specifies this power enclosure in the rack."
+ ::= { cpqRackPowerEnclosureEntry 2 }
+
+ cpqRackPowerEnclosureName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the power enclosure.
+
+ The string will be empty if the enclosure does not report the
+ name or it could not be determined."
+ ::= { cpqRackPowerEnclosureEntry 3 }
+
+ cpqRackPowerEnclosureMgmtBoardSerialNum OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The serial number of the enclosure.
+
+ The string will be empty if the enclosure does not report the
+ serial number."
+ ::= { cpqRackPowerEnclosureEntry 4 }
+
+ cpqRackPowerEnclosureRedundant OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1),
+ notRedundant(2),
+ redundant(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This indicates if the power supply enclosure is in a redundant
+ state."
+ ::= { cpqRackPowerEnclosureEntry 5 }
+
+ cpqRackPowerEnclosureLoadBalanced OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1),
+ notLoadBalanced(2),
+ loadBalanced(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This indicates if the power supply enclosure is in a load
+ balanced state."
+ ::= { cpqRackPowerEnclosureEntry 6 }
+
+ cpqRackPowerEnclosureInputPwrType OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1),
+ singlePhase(2),
+ threePhase(3),
+ directCurrent(4)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This indicates type of input facility power."
+ ::= { cpqRackPowerEnclosureEntry 7 }
+
+ cpqRackPowerEnclosurePwrFeedMax OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This is the maximum facility power in watts.
+
+ The maximum facility power being fed to this power enclosure.
+
+ The value will be -1 if the power enclosure does not report the
+ value or if the value is not known."
+ ::= { cpqRackPowerEnclosureEntry 8 }
+
+ cpqRackPowerEnclosureCondition OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1),
+ ok(2),
+ degraded(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This indicates current condition of the power enclosure.
+
+ other(1)
+ The power enclosure condition could not be determined.
+
+ ok(2)
+ The power enclosure is operating normally.
+
+ degraded(3)
+ The power enclosure is in a degraded state. The power subsystem
+ may not be load balanced or may have lost redundancy."
+ ::= { cpqRackPowerEnclosureEntry 9 }
+
+ cpqRackPowerEnclosureBladeAutopoweron OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1),
+ disabled(2),
+ enabled(3)
+ }
+ ACCESS read-write
+ STATUS optional
+ DESCRIPTION
+ "This indicates current condition of the power enclosure.
+
+ other(1)
+ The blade auto power on feature could not be determined.
+
+ disabled(2)
+ The enclosure will not automatically power on a blade when inserted.
+
+ enabled(3)
+ The enclosure will automatically power on a blade when inserted."
+ ::= { cpqRackPowerEnclosureEntry 10 }
+
+-- ****************************************************************************
+-- The cpqRackLastEAEEvent holds data for last EAE event
+--
+-- The compaq enterprise (1.3.6.1.4.1.232)
+-- cpqRackInfo Group (1.3.6.1.4.1.232.22)
+-- cpqRackComponent Group (1.3.6.1.4.1.232.22.2)
+-- cpqRackEnclosure Group (1.3.6.1.4.1.232.22.2.3)
+-- cpqRackServerEnclosure Group (1.3.6.1.4.1.232.22.2.3.2)
+-- cpqRackLastEAEEvent (1.3.6.1.4.1.232.22.2.3.2.2)
+--
+-- Implementation of this group is optional.
+--
+-- ****************************************************************************
+ cpqRackLastEAEEvent OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..512))
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "Data for the last EAE event."
+--
+-- This is the data variable that is sent with the generics EAE trap below.
+--
+ ::= { cpqRackServerEnclosure 2 }
+
+-- ****************************************************************************
+-- Rack Server Blade Table
+-- =======================
+--
+-- The compaq enterprise (1.3.6.1.4.1.232)
+-- cpqRackInfo Group (1.3.6.1.4.1.232.22)
+-- cpqRackComponent Group (1.3.6.1.4.1.232.22.2)
+-- cpqRackServer Group (1.3.6.1.4.1.232.22.2.4)
+-- cpqRackServerBlade Group (1.3.6.1.4.1.232.22.2.4.1)
+-- cpqRackServerBladeTable (1.3.6.1.4.1.232.22.2.4.1.1)
+--
+-- ****************************************************************************
+
+ cpqRackServerBladeTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CpqRackServerBladeEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A table of rack server blade information."
+ ::= { cpqRackServerBlade 1 }
+
+ cpqRackServerBladeEntry OBJECT-TYPE
+ SYNTAX CpqRackServerBladeEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A rack server blade description."
+ INDEX { cpqRackServerBladeRack,
+ cpqRackServerBladeChassis,
+ cpqRackServerBladeIndex }
+ ::= { cpqRackServerBladeTable 1 }
+
+ CpqRackServerBladeEntry ::= SEQUENCE {
+ cpqRackServerBladeRack INTEGER,
+ cpqRackServerBladeChassis INTEGER,
+ cpqRackServerBladeIndex INTEGER,
+ cpqRackServerBladeName DisplayString,
+ cpqRackServerBladeEnclosureName DisplayString,
+ cpqRackServerBladePartNumber DisplayString,
+ cpqRackServerBladeSparePartNumber DisplayString,
+ cpqRackServerBladePosition INTEGER,
+ cpqRackServerBladeHeight INTEGER,
+ cpqRackServerBladeWidth INTEGER,
+ cpqRackServerBladeDepth INTEGER,
+ cpqRackServerBladePresent INTEGER,
+ cpqRackServerBladeHasFuses INTEGER,
+ cpqRackServerBladeEnclosureSerialNum DisplayString,
+ cpqRackServerBladeSlotsUsed INTEGER,
+ cpqRackServerBladeSerialNum DisplayString,
+ cpqRackServerBladeProductId DisplayString,
+ cpqRackServerBladeUid DisplayString,
+ cpqRackServerBladeSlotsUsedX INTEGER,
+ cpqRackServerBladeSlotsUsedY INTEGER,
+ cpqRackServerBladeStatus INTEGER,
+ cpqRackServerBladeFaultMajor INTEGER,
+ cpqRackServerBladeFaultMinor INTEGER,
+ cpqRackServerBladeFaultDiagnosticString DisplayString,
+ cpqRackServerBladePowered INTEGER,
+ cpqRackServerBladeUIDState INTEGER,
+ cpqRackServerBladeSystemBIOSRevision DisplayString,
+ cpqRackServerBladeSystemBIOSFlashingStatus INTEGER,
+ cpqRackServerBladeHasManagementDevice INTEGER,
+ cpqRackServerBladeManagementDeviceFirmwareRevision DisplayString,
+ cpqRackServerBladeManagementDeviceFirmwareFlashingStatus INTEGER,
+ cpqRackServerBladeDiagnosticAdaptorPresence INTEGER,
+ cpqRackServerBladeASREnabled INTEGER,
+ cpqRackServerBladeFrontIOBlankingModeStatus INTEGER,
+ cpqRackServerBladePOSTStatus INTEGER,
+ cpqRackServerBladePXEBootModeStatus INTEGER,
+ cpqRackServerBladePendingBootOrderChange INTEGER,
+ cpqRackServerBladeWattageMax INTEGER,
+ cpqRackServerBladeWattageAvg INTEGER,
+ cpqRackServerBladeWattageMin INTEGER
+ }
+
+ cpqRackServerBladeRack OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A number that uniquely specifies this rack."
+ ::= { cpqRackServerBladeEntry 1 }
+
+ cpqRackServerBladeChassis OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A number that uniquely specifies this enclosure in the rack."
+ ::= { cpqRackServerBladeEntry 2 }
+
+ cpqRackServerBladeIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A number that uniquely specifies this server blade within the enclosure."
+ ::= { cpqRackServerBladeEntry 3 }
+
+ cpqRackServerBladeName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the server blade.
+
+ The string will be empty if it could not be determined."
+ ::= { cpqRackServerBladeEntry 4 }
+
+ cpqRackServerBladeEnclosureName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the enclosure which contains the blade.
+
+ The string will be empty if the enclosure does not report the
+ name or it could not be determined."
+ ::= { cpqRackServerBladeEntry 5 }
+
+ cpqRackServerBladePartNumber OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The part number of the server blade.
+
+ The string will be empty if the part number could not be
+ determined."
+ ::= { cpqRackServerBladeEntry 6 }
+
+ cpqRackServerBladeSparePartNumber OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The spare part number of the server blade.
+
+ The string will be empty if the part number could not be
+ determined."
+ ::= { cpqRackServerBladeEntry 7 }
+
+ cpqRackServerBladePosition OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The position or slot number of the server blade within the
+ server enclosure.
+
+ This will be -1 if the server enclosure does not report the
+ information or it could not be determined."
+ ::= { cpqRackServerBladeEntry 8 }
+
+ cpqRackServerBladeHeight OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The height dimension of the rack space taken by the server
+ blade expressed in millimeters.
+
+ This will be -1 if the rack does not report the information or
+ it could not be determined."
+ ::= { cpqRackServerBladeEntry 9 }
+
+ cpqRackServerBladeWidth OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The width dimension of the rack space taken by the server
+ blade expressed in millimeters.
+
+ This will be -1 if the rack does not report the information or
+ it could not be determined."
+ ::= { cpqRackServerBladeEntry 10 }
+
+ cpqRackServerBladeDepth OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The depth dimension of the rack space taken by the server
+ blade expressed in millimeters.
+
+ This will be -1 if the rack does not report the information or
+ it could not be determined."
+ ::= { cpqRackServerBladeEntry 11 }
+
+ cpqRackServerBladePresent OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1),
+ absent(2),
+ present(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This specifies if the server blade described is present in the
+ enclosure."
+ ::= { cpqRackServerBladeEntry 12 }
+
+ cpqRackServerBladeHasFuses OBJECT-TYPE
+ SYNTAX INTEGER {
+ false(1),
+ true(2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The server blade contains fuses.
+
+ This will be true(2) is the server blade contains fuses.
+ The cpqRackCommonEnclosureFuseTable will contain the fuse
+ specific information.
+
+ Match the cpqRackServerBladeEnclosureSerialNum in this table to the
+ serial number in the cpqRackCommonEnclosureFanTable to get complete
+ information on the fuses."
+ ::= { cpqRackServerBladeEntry 13 }
+
+ cpqRackServerBladeEnclosureSerialNum OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The serial number of the enclosure which contains the blade.
+
+ The string will be empty if the enclosure does not report the
+ serial number or it could not be determined."
+ ::= { cpqRackServerBladeEntry 14 }
+
+ cpqRackServerBladeSlotsUsed OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of slot positions occupied by this server blade. This
+ is used to indicate a server blade which may obscure an adjacent
+ blade slot.
+
+ This will be -1 if the rack does not report the information or
+ it could not be determined."
+ ::= { cpqRackServerBladeEntry 15 }
+
+ cpqRackServerBladeSerialNum OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The serial number of the server blade.
+
+ The string will be empty if the system does not report the
+ serial number function."
+ ::= { cpqRackServerBladeEntry 16 }
+
+ cpqRackServerBladeProductId OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The product id string of the server blade.
+
+ The string will be empty if the system does not report the
+ product id function."
+ ::= { cpqRackServerBladeEntry 17 }
+
+ cpqRackServerBladeUid OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The server blade unique identifier (UUID).
+
+ The string will be empty if the blade does not report the
+ UUID or if it could not be determined."
+ ::= { cpqRackServerBladeEntry 18 }
+
+ cpqRackServerBladeSlotsUsedX OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of slot positions in x-direction (from left to right)
+ occupied by this server blade. This is used to indicate a server blade
+ which may obscure an adjacent blade slot.
+
+ This will be -1 if the rack does not report the information or
+ it could not be determined."
+ ::= { cpqRackServerBladeEntry 19 }
+
+ cpqRackServerBladeSlotsUsedY OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of slot positions in y-direction (from top to bottom)
+ occupied by this server blade. This is used to indicate a server blade
+ which may obscure an adjacent blade slot.
+
+ This will be -1 if the rack does not report the information or
+ it could not be determined."
+ ::= { cpqRackServerBladeEntry 20 }
+
+ cpqRackServerBladeStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1),
+ ok(2),
+ degraded(3),
+ failed(4)
+ }
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "The health status of the blade.
+
+ This will be other(1) if the rack does not report the information
+ or if it could not be determined."
+ ::= { cpqRackServerBladeEntry 21 }
+
+ cpqRackServerBladeFaultMajor OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "The major fault code of the blade fault
+ reported by the enclosure manager.
+
+ This will be -1 if the rack does not report the information or
+ if it could not be determined."
+ ::= { cpqRackServerBladeEntry 22 }
+
+ cpqRackServerBladeFaultMinor OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "The minor fault code of the blade fault
+ reported by the enclosure manager.
+
+ This will be -1 if the rack does not report the information or
+ if it could not be determined."
+ ::= { cpqRackServerBladeEntry 23 }
+
+ cpqRackServerBladeFaultDiagnosticString OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..128))
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "The server blade fault diagnostic string. This will contain a probable
+ cause and potential diagnostic action to be taken to remedy the fault condition.
+
+ The string will be empty if the blade does not report the
+ diagnostic string or if it could not be determined."
+ ::= { cpqRackServerBladeEntry 24 }
+
+ cpqRackServerBladePowered OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1),
+ on(2),
+ off(3),
+ powerStagedOff(4),
+ reboot(5)
+ }
+
+ ACCESS read-write
+ STATUS optional
+ DESCRIPTION
+ "The power state of the blade.
+
+ This will be other(1) if the rack does not report the information or if it could not be determined."
+ ::= { cpqRackServerBladeEntry 25 }
+
+ cpqRackServerBladeUIDState OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1), -- Unknown device or could not be determined
+ none(2), -- No Unit Identifier LED present
+ ledOn(3), -- Unit Identifier LED is On
+ ledOff(4) -- Unit Identifier LED is Off
+ }
+ ACCESS read-write
+ STATUS optional
+ DESCRIPTION
+ "The Unit Identifier LED.
+
+ This value will be one of the following:
+
+ other(1)
+ The state of the LED could not be determined. Setting the
+ LED state is not allowed.
+
+ none(2)
+ The LED is not present. Setting LED state is not allowed.
+
+ ledOn(3)
+ The LED is present and ON. The LED can be turned off
+ by setting the cpqRackServerBladeUIDState to ledOff(4).
+
+ ledOff(4)
+ The LED is present and OFF. The LED can be turned on
+ by setting the cpqRackServerBladeUIDState to ledOn(3).
+ "
+ ::= { cpqRackServerBladeEntry 26 }
+
+ cpqRackServerBladeSystemBIOSRevision OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "The server blade system bios revision.
+
+ The string will be empty if the blade does not report the
+ system bios revision or if it could not be determined."
+ ::= { cpqRackServerBladeEntry 27 }
+
+ cpqRackServerBladeSystemBIOSFlashingStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1), -- Status Unknown or could not be determined
+ normal(2), -- Blade sytem BIOS not currently in flash mode
+ flashing(3) -- Blade sytem BIOS currently in flash mode
+ }
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "Blade server system BIOS flashing / flash mode status indication.
+
+ This will be other(1) if the rack does not report the information or if it could not be determined."
+ ::= { cpqRackServerBladeEntry 28 }
+
+ cpqRackServerBladeHasManagementDevice OBJECT-TYPE
+ SYNTAX INTEGER {
+ false(1),
+ true(2)
+ }
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "The blade server contains one or more management devices.
+
+ This will be true(2) if the blade server contains managers and false (1) if not
+ or if it can't be detected."
+ ::= { cpqRackServerBladeEntry 29 }
+
+ cpqRackServerBladeManagementDeviceFirmwareRevision OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "The server blade management device firwmware revision.
+
+ The string will be empty if the blade does not report the
+ management device firwmware revision or if it could not be determined."
+ ::= { cpqRackServerBladeEntry 30 }
+
+ cpqRackServerBladeManagementDeviceFirmwareFlashingStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1), -- Status Unknown or could not be determined
+ normal(2), -- Blade sytem management device not currently in flash mode
+ flashing(3) -- Blade sytem management device currently in flash mode
+ }
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "Blade server management device firwmware flashing / flash mode status indication.
+
+ This will be other(1) if the rack does not report this information or if it could not be determined."
+ ::= { cpqRackServerBladeEntry 31 }
+
+ cpqRackServerBladeDiagnosticAdaptorPresence OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1),
+ absent(2),
+ present(3)
+ }
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "This specifies if a blade diagnostic adaptor is currently plugged into the system."
+ ::= { cpqRackServerBladeEntry 32 }
+
+ cpqRackServerBladeASREnabled OBJECT-TYPE
+ SYNTAX INTEGER {
+ false(1),
+ true(2)
+ }
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "Indicates whether the target blade server has Automatic Service Recovery feature enabled.
+
+ This will be true(2) if the blade server has this feature eanbled and false (1) if not
+ or if it can't be detected."
+ ::= { cpqRackServerBladeEntry 33 }
+
+ cpqRackServerBladeFrontIOBlankingModeStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(1),
+ inactive(2),
+ active(3)
+ }
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "Indicates whether the target blade server has the front IO ports blanking feature enabled.
+
+ This will be Active(3) if the blade server has this feature eanbled, Inactive (2) if not,
+ or Unknown(1) if it can't be determined."
+ ::= { cpqRackServerBladeEntry 34 }
+
+ cpqRackServerBladePOSTStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1), -- POST Status Unknown or could not be determined
+ started(2), -- Blade has started Power-on-self-test (POST) process
+ completed(3), -- Blade has finished Power-on-self-test (POST) process
+ failed(4) -- Blade has failed to complete Power-on-self-test (POST) process and halted
+ }
+
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "Blade server power-on self test (POST) status.
+
+ This value will be one of the following:
+
+ other(1)
+ The state of the blade POST could not be determined.
+
+ started(2)
+ Blade has started Power-on-self-test (POST) process.
+
+ completed(3)
+ Blade has finished Power-on-self-test (POST) process.
+
+ failed(4)
+ Blade has failed to complete Power-on-self-test (POST) process and halted.
+
+ This will be other(1) if the rack does not report this information or if it could not be determined."
+ ::= { cpqRackServerBladeEntry 35 }
+
+ cpqRackServerBladePXEBootModeStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(1),
+ inactive(2),
+ active(3)
+ }
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "Indicates whether the target blade server is in PXE boot mode.
+
+ This will be Active(3) if the blade server has this feature enbled, Inactive (2) if not,
+ or Unknown(1) if it can't be determined."
+ ::= { cpqRackServerBladeEntry 36 }
+
+ cpqRackServerBladePendingBootOrderChange OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1), --Unknown or cannot be determined
+ none(2), --No Changes
+ firstPXE(3), --Boot To Pre-Boot eXecution (PXE) First
+ firstHDD(4), --First Boot To Local HD
+ firstRBSU(5), --First Boot To ROM Based Setup Utility
+ oncePXE(6), --Boot To Pre-Boot eXecution (PXE) Once
+ onceHDD(7), --Boot To Local HD Once
+ onceRBSU(8), --Boot To ROM Based Setup Utility Once
+ alwaysPXE(9), --Always Boot To Pre-Boot eXecution (PXE)
+ alwaysHDD(10), --Always Boot To Local HD
+ alwaysRBSU(11) --Always Boot To ROM Based Setup Utility
+ }
+ ACCESS read-write
+ STATUS optional
+ DESCRIPTION
+ "Blade server pending boot order setting change state.
+
+ This value will be one of the following:
+
+ other(1) - Unknown or cannot be determined
+ none(2) - No Changes
+ firstPXE(3) - Boot To Pre-Boot eXecution (PXE) First
+ firstHDD(4) - First Boot To Local HD
+ firstRBSU(5) - First Boot To ROM Based Setup Utility
+ oncePXE(6) - Boot To Pre-Boot eXecution (PXE) Once
+ onceHDD(7) - Boot To Local HD Once
+ onceRBSU(8) - Boot To ROM Based Setup Utility Once
+ alwaysPXE(9) - Always Boot To Pre-Boot eXecution (PXE)
+ alwaysHDD(10) - Always Boot To Local HD
+ alwaysRBSU(11) - Always Boot To ROM Based Setup Utility
+
+ This will be other(1) if the rack does not report this information or if it could not be determined."
+ ::= { cpqRackServerBladeEntry 37 }
+
+ cpqRackServerBladeWattageMax OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "Maximum wattage the server has consumed during this power cycle."
+ ::= { cpqRackServerBladeEntry 38 }
+
+ cpqRackServerBladeWattageAvg OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "Average wattage the server is consuming, averaged over a period defined by the product."
+ ::= { cpqRackServerBladeEntry 39 }
+
+ cpqRackServerBladeWattageMin OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "Minimum wattage the server has consumed, computed from a period defined by the product. Value
+ will be 0 if not supported, but other wattage values are supported."
+ ::= { cpqRackServerBladeEntry 40 }
+
+-- ****************************************************************************
+-- Rack Server Networking Table
+-- =======================
+--
+-- The compaq enterprise (1.3.6.1.4.1.232)
+-- cpqRackInfo Group (1.3.6.1.4.1.232.22)
+-- cpqRackComponent Group (1.3.6.1.4.1.232.22.2)
+-- cpqRackServer Group (1.3.6.1.4.1.232.22.2.4)
+-- cpqRackServerNetworking Group (1.3.6.1.4.1.232.22.2.4.2)
+-- cpqRackServerNetworkingTable (1.3.6.1.4.1.232.22.2.4.2.1)
+--
+-- ****************************************************************************
+
+ cpqRackServerNetworkingTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CpqRackServerNetworkingEntry
+ ACCESS not-accessible
+ STATUS optional
+ DESCRIPTION
+ "A table of rack server networking information."
+ ::= { cpqRackServerNetworking 1 }
+
+ cpqRackServerNetworkingEntry OBJECT-TYPE
+ SYNTAX CpqRackServerNetworkingEntry
+ ACCESS not-accessible
+ STATUS optional
+ DESCRIPTION
+ "A rack server networking description."
+ INDEX { cpqRackServerNetworkingRack,
+ cpqRackServerNetworkingChassis,
+ cpqRackServerNetworkingIndex }
+ ::= { cpqRackServerNetworkingTable 1 }
+
+ CpqRackServerNetworkingEntry ::= SEQUENCE {
+ cpqRackServerNetworkingRack INTEGER,
+ cpqRackServerNetworkingChassis INTEGER,
+ cpqRackServerNetworkingIndex INTEGER,
+ cpqRackServerNetworkingName DisplayString,
+ cpqRackServerNetworkingEnclosureName DisplayString,
+ cpqRackServerNetworkingEthernetInterfaces INTEGER,
+ cpqRackServerNetworkingEthernetMACAddress DisplayString
+ }
+
+ cpqRackServerNetworkingRack OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "A number that uniquely specifies this rack."
+ ::= { cpqRackServerNetworkingEntry 1 }
+
+ cpqRackServerNetworkingChassis OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A number that uniquely specifies this enclosure in the rack."
+ ::= { cpqRackServerNetworkingEntry 2 }
+
+ cpqRackServerNetworkingIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "A number that uniquely specifies this server within the enclosure."
+ ::= { cpqRackServerNetworkingEntry 3 }
+
+ cpqRackServerNetworkingName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "The name of the server.
+
+ The string will be empty if it could not be determined."
+ ::= { cpqRackServerNetworkingEntry 4 }
+
+ cpqRackServerNetworkingEnclosureName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "The name of the enclosure which contains the server.
+
+ The string will be empty if the enclosure does not report the
+ name or if it could not be determined."
+ ::= { cpqRackServerNetworkingEntry 5 }
+
+ cpqRackServerNetworkingEthernetInterfaces OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "A number that specifies the amount of
+ Ethernet network interfaces in the server."
+ ::= { cpqRackServerNetworkingEntry 6 }
+
+ cpqRackServerNetworkingEthernetMACAddress OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "The MAC address for the Ethernet NIC populated in the server.
+
+ The string will be empty if it could not be determined."
+ ::= { cpqRackServerNetworkingEntry 7 }
+
+-- ****************************************************************************
+-- Rack Server Temperature Sensor Table
+-- =======================
+--
+-- The compaq enterprise (1.3.6.1.4.1.232)
+-- cpqRackInfo Group (1.3.6.1.4.1.232.22)
+-- cpqRackComponent Group (1.3.6.1.4.1.232.22.2)
+-- cpqRackServer Group (1.3.6.1.4.1.232.22.2.4)
+-- cpqRackServerTempSensor Group (1.3.6.1.4.1.232.22.2.4.3)
+-- cpqRackServerTempSensorTable (1.3.6.1.4.1.232.22.2.4.3.1)
+--
+-- ****************************************************************************
+
+ cpqRackServerTempSensorTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CpqRackServerTempSensorEntry
+ ACCESS not-accessible
+ STATUS optional
+ DESCRIPTION
+ "A table of rack server temperature sensor information."
+ ::= { cpqRackServerTempSensor 1 }
+
+ cpqRackServerTempSensorEntry OBJECT-TYPE
+ SYNTAX CpqRackServerTempSensorEntry
+ ACCESS not-accessible
+ STATUS optional
+ DESCRIPTION
+ "A rack server temperature sensor description."
+ INDEX { cpqRackServerTempSensorRack,
+ cpqRackServerTempSensorChassis,
+ cpqRackServerTempSensorIndex }
+ ::= { cpqRackServerTempSensorTable 1 }
+
+ CpqRackServerTempSensorEntry ::= SEQUENCE {
+ cpqRackServerTempSensorRack INTEGER,
+ cpqRackServerTempSensorChassis INTEGER,
+ cpqRackServerTempSensorIndex INTEGER,
+ cpqRackServerTempSensorName DisplayString,
+ cpqRackServerTempSensorEnclosureName DisplayString,
+ cpqRackServerTempSensorCount INTEGER,
+ cpqRackServerTempSensorLocation DisplayString,
+ cpqRackServerTempSensorCurrent INTEGER,
+ cpqRackServerTempSensorThreshold INTEGER,
+ cpqRackServerTempSensorCondition INTEGER,
+ cpqRackServerTempSensorType INTEGER
+ }
+
+ cpqRackServerTempSensorRack OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "A number that uniquely specifies this rack."
+ ::= { cpqRackServerTempSensorEntry 1 }
+
+ cpqRackServerTempSensorChassis OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "A number that uniquely specifies this enclosure in the rack."
+ ::= { cpqRackServerTempSensorEntry 2 }
+
+ cpqRackServerTempSensorIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "A number that uniquely specifies this server within the enclosure."
+ ::= { cpqRackServerTempSensorEntry 3 }
+
+ cpqRackServerTempSensorName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "The name of the server.
+
+ The string will be empty if it could not be determined."
+ ::= { cpqRackServerTempSensorEntry 4 }
+
+ cpqRackServerTempSensorEnclosureName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "The name of the enclosure which contains the server.
+
+ The string will be empty if the enclosure does not report the
+ name or if it could not be determined."
+ ::= { cpqRackServerTempSensorEntry 5 }
+
+ cpqRackServerTempSensorCount OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "A number that specifies the amount of
+ temperature sensors in the server."
+ ::= { cpqRackServerTempSensorEntry 6 }
+
+ cpqRackServerTempSensorLocation OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "The location description of the temperature sensor within the
+ blade server.
+
+ The string will be empty if it could not be determined."
+ ::= { cpqRackServerTempSensorEntry 7 }
+
+ cpqRackServerTempSensorCurrent OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "This is the current temperature sensor reading in degrees
+ celsius.
+
+ If this value cannot be determined by software, then a value
+ of -1 will be returned."
+ ::= { cpqRackServerTempSensorEntry 8 }
+
+ cpqRackServerTempSensorThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "This is the threshold temperature sensor setting
+ in degrees celsius. This is the temperature in which the
+ sensor will be considered to be in a tripped state this
+ causing some action to occur depending on the type of
+ the sensor. The action of temperature sensor threshold
+ will be indicated by the cpqRackServerTempSensorType
+ item. If the type is blowout(5), then the temperature sensor
+ will cause the fans to speed up. If the type is caution(9),
+ then the temperature sensor is in a degraded state. If the
+ type is critical(15), then the enclosure will be considered
+ as in a failed state.
+
+ If this value cannot be determined by software, then a value
+ of -1 will be returned."
+ ::= { cpqRackServerTempSensorEntry 9 }
+
+ cpqRackServerTempSensorCondition OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1),
+ ok(2),
+ degraded(3),
+ failed(4)
+ }
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "The Temperature sensor condition.
+
+ This value will be one of the following:
+
+ other(1)
+ Temperature could not be determined.
+
+ ok(2)
+ The temperature sensor is within the normal operating range.
+
+ degraded(3)
+ The temperature sensor is outside of the normal operating range.
+
+ failed(4)
+ The temperature sensor detects a condition that could
+ possibly overheat the system.
+
+ The system will automatically shutdown if the failed(4) condition
+ results, so it is unlikely that this value will ever be returned
+ by the agent."
+ ::= { cpqRackServerTempSensorEntry 10 }
+
+ cpqRackServerTempSensorType OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1),
+ blowout(5),
+ caution(9),
+ critical(15)
+ }
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "This specifies the type of this instance of temperature
+ sensor.
+
+ This value will be one of the following:
+
+ other(1)
+ Temperature threshold type could not be determined.
+
+ blowout(5)
+ If a blowout(5) temperature sensor reaches its threshold,
+ the fan or fans in the area of the temperature sensor will
+ increase in speed in an attempt to reduce the temperature
+ before a caution or critical threshold is reached.
+
+ caution(9)
+ If a caution(9) temperature sensor reaches its threshold, the
+ cpqRackServerTempSensorCondition will be set to degraded(3)
+ and the system will either continue or shutdown depending
+ on the local blade server policy settings.
+
+ critical(15)
+ If a critical(15) temperature sensor reaches its threshold,
+ cpqRackServerTempSensorCondition will be set to failed(4)
+ and the blade server will shutdown."
+ ::= { cpqRackServerTempSensorEntry 11 }
+
+-- ****************************************************************************
+-- Rack Power Supply Table
+-- =======================
+--
+-- The compaq enterprise (1.3.6.1.4.1.232)
+-- cpqRackInfo Group (1.3.6.1.4.1.232.22)
+-- cpqRackComponent Group (1.3.6.1.4.1.232.22.2)
+-- cpqRackPower Group (1.3.6.1.4.1.232.22.2.5)
+-- cpqRackPowerSupply Group (1.3.6.1.4.1.232.22.2.5.1)
+-- cpqRackPowerSupplyTable (1.3.6.1.4.1.232.22.2.5.1.1)
+--
+-- ****************************************************************************
+
+ cpqRackPowerSupplyTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CpqRackPowerSupplyEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A table of rack power supply information."
+ ::= { cpqRackPowerSupply 1 }
+
+ cpqRackPowerSupplyEntry OBJECT-TYPE
+ SYNTAX CpqRackPowerSupplyEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A rack power supply description."
+ INDEX { cpqRackPowerSupplyRack,
+ cpqRackPowerSupplyChassis,
+ cpqRackPowerSupplyIndex }
+ ::= { cpqRackPowerSupplyTable 1 }
+
+ CpqRackPowerSupplyEntry ::= SEQUENCE {
+ cpqRackPowerSupplyRack INTEGER,
+ cpqRackPowerSupplyChassis INTEGER,
+ cpqRackPowerSupplyIndex INTEGER,
+ cpqRackPowerSupplyEnclosureName DisplayString,
+ cpqRackPowerSupplySerialNum DisplayString,
+ cpqRackPowerSupplyPartNumber DisplayString,
+ cpqRackPowerSupplySparePartNumber DisplayString,
+ cpqRackPowerSupplyFWRev DisplayString,
+ cpqRackPowerSupplyMaxPwrOutput INTEGER,
+ cpqRackPowerSupplyCurPwrOutput INTEGER,
+ cpqRackPowerSupplyPosition INTEGER,
+ cpqRackPowerSupplyIntakeTemp INTEGER,
+ cpqRackPowerSupplyExhaustTemp INTEGER,
+ cpqRackPowerSupplyStatus INTEGER,
+ cpqRackPowerSupplyInputLineStatus INTEGER,
+ cpqRackPowerSupplyPresent INTEGER,
+ cpqRackPowerSupplyCondition INTEGER,
+ cpqRackPowerSupplyEnclosureSerialNum DisplayString
+ }
+
+ cpqRackPowerSupplyRack OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A number that uniquely specifies this rack."
+ ::= { cpqRackPowerSupplyEntry 1 }
+
+ cpqRackPowerSupplyChassis OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A number that uniquely specifies this power enclosure in the rack."
+ ::= { cpqRackPowerSupplyEntry 2 }
+
+ cpqRackPowerSupplyIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A number that uniquely specifies this power supply in the enclosure."
+ ::= { cpqRackPowerSupplyEntry 3 }
+
+ cpqRackPowerSupplyEnclosureName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the power supply enclosure in which this power supply
+ resides.
+
+ The string will be empty if the enclosure does not report the
+ name or it could not be determined."
+ ::= { cpqRackPowerSupplyEntry 4 }
+
+ cpqRackPowerSupplySerialNum OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The serial number of the power supply.
+
+ The string will be empty if the power supply does not report the
+ serial number."
+ ::= { cpqRackPowerSupplyEntry 5 }
+
+ cpqRackPowerSupplyPartNumber OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The part number of the power supply.
+
+ The string will be empty if the power supply does not report this
+ function."
+ ::= { cpqRackPowerSupplyEntry 6 }
+
+ cpqRackPowerSupplySparePartNumber OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The spare part number of the power supply.
+
+ The string will be empty if the power supply does not report this
+ function."
+ ::= { cpqRackPowerSupplyEntry 7 }
+
+ cpqRackPowerSupplyFWRev OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The firmware revision of the power supply.
+
+ The string will be empty if the power supply does not report the
+ firmware revision."
+ ::= { cpqRackPowerSupplyEntry 8 }
+
+ cpqRackPowerSupplyMaxPwrOutput OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The maximum power output of the power supply in watts.
+
+ The value will be -1 if the power supply does not report the
+ value."
+ ::= { cpqRackPowerSupplyEntry 9 }
+
+ cpqRackPowerSupplyCurPwrOutput OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The current power output of the power supply in watts.
+
+ The value will be -1 if the power supply does not report the
+ value."
+ ::= { cpqRackPowerSupplyEntry 10 }
+
+ cpqRackPowerSupplyPosition OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The position of the power supply within the power enclosure.
+
+ This will be -1 if the power enclosure does not report the
+ power supply information or it could not be determined."
+ ::= { cpqRackPowerSupplyEntry 11 }
+
+ cpqRackPowerSupplyIntakeTemp OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The current air temperature at the intake of the power supply
+ in degrees celsius.
+
+ The value will be -1 if the power supply does not report the
+ value."
+ ::= { cpqRackPowerSupplyEntry 12 }
+
+ cpqRackPowerSupplyExhaustTemp OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The current air temperature at the exhaust of the power supply
+ in degrees celsius.
+
+ The value will be -1 if the power supply does not report the
+ value."
+ ::= { cpqRackPowerSupplyEntry 13 }
+
+ cpqRackPowerSupplyStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ noError(1),
+ generalFailure(2),
+ bistFailure(3),
+ fanFailure(4),
+ tempFailure(5),
+ interlockOpen(6),
+ epromFailed(7),
+ vrefFailed(8),
+ dacFailed(9),
+ ramTestFailed(10),
+ voltageChannelFailed(11),
+ orringdiodeFailed(12),
+ brownOut(13),
+ giveupOnStartup(14),
+ nvramInvalid(15),
+ calibrationTableInvalid(16)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The status of the power supply."
+ ::= { cpqRackPowerSupplyEntry 14 }
+
+ cpqRackPowerSupplyInputLineStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ noError(1),
+ lineOverVoltage(2),
+ lineUnderVoltage(3),
+ lineHit(4),
+ brownOut(5),
+ linePowerLoss(6)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The status of line input power."
+ ::= { cpqRackPowerSupplyEntry 15 }
+
+ cpqRackPowerSupplyPresent OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1),
+ absent(2),
+ present(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This specifies if the power supply described is present in the
+ enclosure."
+ ::= { cpqRackPowerSupplyEntry 16 }
+
+ cpqRackPowerSupplyCondition OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1),
+ ok(2),
+ degraded(3),
+ failed(4)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The condition of the power supply.
+
+ This value will be one of the following:
+
+ other(1)
+ The status could not be determined or not present.
+
+ ok(2)
+ The power supply is operating normally.
+
+ degraded(3)
+ A temperature sensor, fan or other power supply component is
+ outside of normal operating range.
+
+ failed(4)
+ A power supply component detects a condition that could
+ possibly damage the system."
+ ::= { cpqRackPowerSupplyEntry 17 }
+
+ cpqRackPowerSupplyEnclosureSerialNum OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The serial number of the power supply enclosure in which this
+ power supply resides.
+
+ The string will be empty if the enclosure does not report the
+ serial number or it could not be determined."
+ ::= { cpqRackPowerSupplyEntry 18 }
+
+-- ****************************************************************************
+-- Rack Network
+-- ============
+--
+-- The compaq enterprise (1.3.6.1.4.1.232)
+-- cpqRackInfo Group (1.3.6.1.4.1.232.22)
+-- cpqRackComponent Group (1.3.6.1.4.1.232.22.2)
+-- cpqRackNetwork Group (1.3.6.1.4.1.232.22.2.6)
+--
+-- ****************************************************************************
+
+ cpqRackNetworkAddressesTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CpqRackNetworkAddressesEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A table of rack network addresses."
+ ::= { cpqRackNetwork 2}
+
+ cpqRackNetworkAddressesEntry OBJECT-TYPE
+ SYNTAX CpqRackNetworkAddressesEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Array of ALL the network addresses of the system generating the indication.
+
+ This may include IPv4 addresses (based on IETF RFC 1208) or IPv6 addresses
+ (based on IETF RFC 4291)."
+ INDEX { cpqRackNetworkAddresses }
+ ::= { cpqRackNetworkAddressesTable 1}
+
+ CpqRackNetworkAddressesEntry ::= SEQUENCE {
+ cpqRackNetworkAddresses DisplayString
+ }
+
+ cpqRackNetworkAddresses OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..50))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A network address of the system generating the indication."
+ ::= { cpqRackNetworkAddressesEntry 1}
+
+
+-- ****************************************************************************
+-- Rack Network Connector Table
+-- ============================
+--
+-- The compaq enterprise (1.3.6.1.4.1.232)
+-- cpqRackInfo Group (1.3.6.1.4.1.232.22)
+-- cpqRackComponent Group (1.3.6.1.4.1.232.22.2)
+-- cpqRackNetwork Group (1.3.6.1.4.1.232.22.2.6)
+-- cpqRackNetConnector Group (1.3.6.1.4.1.232.22.2.6.1)
+-- cpqRackNetConnectorTable (1.3.6.1.4.1.232.22.2.6.1.1)
+--
+-- ****************************************************************************
+
+ cpqRackNetConnectorTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CpqRackNetConnectorEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A table of rack network connector information."
+ ::= { cpqRackNetConnector 1 }
+
+ cpqRackNetConnectorEntry OBJECT-TYPE
+ SYNTAX CpqRackNetConnectorEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A rack network connector description."
+ INDEX { cpqRackNetConnectorRack,
+ cpqRackNetConnectorChassis,
+ cpqRackNetConnectorIndex }
+ ::= { cpqRackNetConnectorTable 1 }
+
+ CpqRackNetConnectorEntry ::= SEQUENCE {
+ cpqRackNetConnectorRack INTEGER,
+ cpqRackNetConnectorChassis INTEGER,
+ cpqRackNetConnectorIndex INTEGER,
+ cpqRackNetConnectorEnclosureName DisplayString,
+ cpqRackNetConnectorName DisplayString,
+ cpqRackNetConnectorModel DisplayString,
+ cpqRackNetConnectorSerialNum DisplayString,
+ cpqRackNetConnectorPartNumber DisplayString,
+ cpqRackNetConnectorSparePartNumber DisplayString,
+ cpqRackNetConnectorFWRev DisplayString,
+ cpqRackNetConnectorType INTEGER,
+ cpqRackNetConnectorLocation DisplayString,
+ cpqRackNetConnectorPresent INTEGER,
+ cpqRackNetConnectorHasFuses INTEGER,
+ cpqRackNetConnectorEnclosureSerialNum DisplayString,
+ cpqRackNetConnectorTechnologyType INTEGER,
+ cpqRackNetConnectorDeviceType INTEGER
+ }
+
+ cpqRackNetConnectorRack OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A number that uniquely specifies this rack."
+ ::= { cpqRackNetConnectorEntry 1 }
+
+ cpqRackNetConnectorChassis OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A number that uniquely specifies this server enclosure in the rack."
+ ::= { cpqRackNetConnectorEntry 2 }
+
+ cpqRackNetConnectorIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A number that uniquely specifies this network connector in the rack."
+ ::= { cpqRackNetConnectorEntry 3 }
+
+ cpqRackNetConnectorEnclosureName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the network connector enclosure.
+
+ The string will be empty if the enclosure does not report the
+ name or it could not be determined."
+ ::= { cpqRackNetConnectorEntry 4 }
+
+ cpqRackNetConnectorName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the network connector.
+
+ The string will be empty if the network connector does not report the
+ name or it could not be determined."
+ ::= { cpqRackNetConnectorEntry 5 }
+
+ cpqRackNetConnectorModel OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The model name of the network connector.
+
+ The string will be empty if the network connector does not report the
+ model information."
+ ::= { cpqRackNetConnectorEntry 6 }
+
+ cpqRackNetConnectorSerialNum OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The serial number of the network connector.
+
+ The string will be empty if the network connector does not report the
+ serial number."
+ ::= { cpqRackNetConnectorEntry 7 }
+
+ cpqRackNetConnectorPartNumber OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The part number of the network connector.
+
+ The string will be empty if the enclosure does not report this
+ function."
+ ::= { cpqRackNetConnectorEntry 8 }
+
+ cpqRackNetConnectorSparePartNumber OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The spare part number of the network connector.
+
+ The string will be empty if the enclosure does not report this
+ function."
+ ::= { cpqRackNetConnectorEntry 9 }
+
+ cpqRackNetConnectorFWRev OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The firmware revision of the network connector.
+
+ The string will be empty if the network connector does not report the
+ firmware revision."
+ ::= { cpqRackNetConnectorEntry 10 }
+
+ cpqRackNetConnectorType OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1),
+ passive(2),
+ active(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The type of network connector within the enclosure."
+ ::= { cpqRackNetConnectorEntry 11 }
+
+ cpqRackNetConnectorLocation OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The location of the network connector within the enclosure."
+ ::= { cpqRackNetConnectorEntry 12 }
+
+ cpqRackNetConnectorPresent OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1),
+ absent(2),
+ present(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This specifies if the network connector described is present in the
+ enclosure."
+ ::= { cpqRackNetConnectorEntry 13 }
+
+ cpqRackNetConnectorHasFuses OBJECT-TYPE
+ SYNTAX INTEGER {
+ false(1),
+ true(2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The network connector contains fuses.
+
+ This will be true(2) is the network connector contains fuses.
+ The cpqRackCommonEnclosureFuseTable will contain the fuse
+ specific information.
+
+ Match the cpqRackNetworkEnclosureSerialNum in this table to the
+ serial number in the cpqRackCommonEnclosureFusTable to get complete
+ information on the fuses."
+ ::= { cpqRackNetConnectorEntry 14 }
+
+ cpqRackNetConnectorEnclosureSerialNum OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The serial number of the enclosure containing the network connector.
+
+ The string will be empty if the enclosure does not report the
+ serial number or it could not be determined."
+ ::= { cpqRackNetConnectorEntry 15 }
+
+ cpqRackNetConnectorTechnologyType OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1),
+ passive(2),
+ active(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The type of network connector within the enclosure."
+ ::= { cpqRackNetConnectorEntry 16 }
+
+ cpqRackNetConnectorDeviceType OBJECT-TYPE
+ SYNTAX INTEGER {
+ noconnect(1),
+ network(2),
+ fibrechannel(3),
+ sas(4),
+ inifiband(5),
+ pciexpress(6)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The type of interrconnect in the enclosure.
+
+ This will be -1 if it is not reported or can not be deteremined."
+ ::= { cpqRackNetConnectorEntry 17 }
+
+-- ****************************************************************************
+-- Rack Hardware Information
+-- =========================
+--
+-- The compaq enterprise (1.3.6.1.4.1.232)
+-- cpqRackInfo Group (1.3.6.1.4.1.232.22)
+-- cpqRackComponent Group (1.3.6.1.4.1.232.22.2)
+-- cpqRackHW Group (1.3.6.1.4.1.232.22.2.7)
+--
+-- ****************************************************************************
+
+ cpqRackHWPartNumber OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..16))
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "Part number for the hardware generating the indication."
+ ::= { cpqRackHW 1 }
+
+ cpqRackHWFirmwareVersionTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CpqRackHWFirmwareVersionEntry
+ ACCESS not-accessible
+ STATUS optional
+ DESCRIPTION
+ "A table of rack firmware versions."
+ ::= { cpqRackHW 2 }
+
+ cpqRackHWFirmwareVersionEntry OBJECT-TYPE
+ SYNTAX CpqRackHWFirmwareVersionEntry
+ ACCESS not-accessible
+ STATUS optional
+ DESCRIPTION
+ "Array of versions of firmware for the hardware associated with the indication."
+ INDEX { cpqRackHWFirmwareVersion }
+ ::= { cpqRackHWFirmwareVersionTable 1 }
+
+ CpqRackHWFirmwareVersionEntry ::= SEQUENCE {
+ cpqRackHWFirmwareVersion DisplayString
+ }
+
+ cpqRackHWFirmwareVersion OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..30))
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "A version of firmware for the hardware associated with the indication."
+ ::= { cpqRackHWFirmwareVersionEntry 1 }
+
+ cpqRackHWManufacturer OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..65))
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "Manufacturer of the hardware associated with the indication.Device indication
+ hardware manufacturer."
+ ::= { cpqRackHW 3 }
+
+ cpqRackHWSerialNumberTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CpqRackHWSerialNumberEntry
+ ACCESS not-accessible
+ STATUS optional
+ DESCRIPTION
+ "A table of rack hardware serial numbers."
+ ::= { cpqRackHW 4 }
+
+ cpqRackHWSerialNumberEntry OBJECT-TYPE
+ SYNTAX CpqRackHWSerialNumberEntry
+ ACCESS not-accessible
+ STATUS optional
+ DESCRIPTION
+ "Array of all the serial numbers of the hardware associated with the indication."
+ INDEX { cpqRackHWSerialNumber }
+ ::= { cpqRackHWSerialNumberTable 1 }
+
+ CpqRackHWSerialNumberEntry ::= SEQUENCE {
+ cpqRackHWSerialNumber DisplayString
+ }
+
+ cpqRackHWSerialNumber OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..21))
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "A serial number of the hardware associated with the indication."
+ ::= { cpqRackHWSerialNumberEntry 1 }
+
+ cpqRackHWFRUDetails OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (0..256))
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "This is used to provide miscellaneous FRU specific details
+
+ Some examples are DIMM size, Processor stepping info etc."
+ ::= { cpqRackHW 5 }
+
+ cpqRackHWDevicePermanentNameFormat OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(1),
+ other(2),
+ worldWideName(3),
+ macAddress(4)
+ }
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "The format of the DevicePermanentName property is interpreted based upon
+ the value of this property.
+
+ Values are defined as:
+ 1 - unknown. The format is not meaningfully interpretable by a CIM client
+ application.
+ 2 - other. The format is defined by the value of the OtherPermanentNameFormat
+ property.
+ 3 - worldWideName. The format is a WorldWideName.
+ 4 - macAddress. The format is a LAN MAC Address."
+ ::= { cpqRackHW 6 }
+
+ cpqRackHWOtherPermanentNameFormat OBJECT-TYPE
+ SYNTAX DisplayString ( SIZE (0..64))
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "A string defining other values for DevicePermanentFormat.
+
+ It is empty unless DevicePermanentFormat value is other."
+ ::= { cpqRackHW 7 }
+
+-- ****************************************************************************
+-- Rack Ers Information
+-- =========================
+--
+-- The compaq enterprise (1.3.6.1.4.1.232)
+-- cpqRackInfo Group (1.3.6.1.4.1.232.22)
+-- cpqRackComponent Group (1.3.6.1.4.1.232.22.2)
+-- cpqRackErs Group (1.3.6.1.4.1.232.22.2.8)
+--
+-- ****************************************************************************
+
+ cpqRackErsTransactionType OBJECT-TYPE
+ SYNTAX INTEGER {
+ registration(1),
+ serviceEvent(2),
+ l2DataCollection(3),
+ unregistration(4)
+ }
+
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Embedded Remote Support transaction type.
+
+ The following values are defined:
+
+ registration(1)
+ Registration operation with Insight Remote Host or Insight Online Host.
+
+ serviceEvent(2)
+ Sending of service event to Insight Remote Host or Insight Online Host.
+
+ l2DataCollection(3)
+ L2 Data collection operation.
+
+ unregistration(4)
+ Unregistration with Insight Remote Host or Insight Online Host."
+ ::= { cpqRackErs 1 }
+
+ cpqRackErsConnectionModel OBJECT-TYPE
+ SYNTAX INTEGER {
+ insightOnline(1),
+ insightRemoteSupport(2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Embedded Remote Support connection model configured on the Onboard Administrator."
+ ::= { cpqRackErs 2 }
+
+ cpqRackErsFailureCode OBJECT-TYPE
+ SYNTAX INTEGER{
+ genericTransmitError(1),
+ clientTransmitTimeout(2),
+ clientReceiveTimeout(3),
+ proxyConnectError(4),
+ remoteHostConnectError(5),
+ remoteServiceError(6)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Embedded Remote Support transaction failure code."
+ ::= { cpqRackErs 3 }
+
+ cpqRackErsRemoteHost OBJECT-TYPE
+ SYNTAX DisplayString ( SIZE (0..135))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Remote destination server's hostname and port as configured on the Onboard Administrator.
+
+ Example: myremotehost.hpe.com:6789"
+ ::= { cpqRackErs 4 }
+
+-- ****************************************************************************
+-- Rack System Object Identification
+-- =================================
+--
+-- The compaq enterprise (1.3.6.1.4.1.232)
+-- cpqRackInfo Group (1.3.6.1.4.1.232.22)
+-- cpqRackSysObjID Group (1.3.6.1.4.1.232.22.3)
+--
+-- ****************************************************************************
+
+ cpqRackSystemObjectIdentification OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The hardware identification string.
+
+ The string will reported by the rack firmware."
+ ::= { cpqRackSysObjID 1 }
+
+-- ****************************************************************************
+-- Rack Event Information
+-- =================================
+--
+-- The compaq enterprise (1.3.6.1.4.1.232)
+-- cpqRackInfo Group (1.3.6.1.4.1.232.22)
+-- cpqRackEventInfo Group (1.3.6.1.4.1.232.22.4)
+--
+-- ****************************************************************************
+
+ cpqRackEventIndicationIdentifier OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..25))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The Event Indication Identifier."
+ ::= { cpqRackEventInfo 1 }
+
+ cpqRackEventIndicationTime OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..33))
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "The Event Indication Time."
+ ::= { cpqRackEventInfo 2 }
+
+ cpqRackEventDescription OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (0..1024))
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "The Event Description."
+ ::= { cpqRackEventInfo 3 }
+
+ cpqRackEventSummary OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..255))
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "Short description of the reason for the event."
+ ::= { cpqRackEventInfo 4 }
+
+ cpqRackEventCategory OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(1),
+ other(2),
+ processor(3),
+ memory(4),
+ systemHardware(5),
+ supportHardware(6),
+ primaryStorageDevice(7),
+ secondaryStorageDevice(8),
+ otherStorageDevice(9),
+ networkDevice(10),
+ otherDevice(11),
+ ioAdapter(12),
+ networkAdapter(13),
+ otherAdapter(14),
+ processorPower(15),
+ memoryPower(16),
+ systemPower(17),
+ primaryStorageDevicePower(18),
+ secondaryStoragePower(19),
+ otherStoragePower(20),
+ otherPower(21),
+ processorCooling(22),
+ memoryCooling(23),
+ systemCooling(24),
+ primaryStorageDeviceCooling(25),
+ secondaryStorageDeviceCooling(26),
+ otherStorageDeviceCooling(27),
+ otherCooling(28),
+ systemHWSecurity(29),
+ primaryStorageDeviceSecurity(30),
+ secondaryStorageDeviceSecurity(31),
+ otherStorageDeviceSecurity(32),
+ otherHWSecurity(33),
+ systemInterconnect(34),
+ supportInterconnect(35),
+ clusterInterconnect(36),
+ storageInterconnect(37),
+ networkInterconnect(38),
+ otherInterconnect(39),
+ os(40),
+ systemFirmware(41),
+ deviceFirmware(42),
+ supportFirmware(43),
+ systemFirmwareSecurity(44),
+ osSecurity(45),
+ softwareApplication(46),
+ softwareApplicationSecurity(47),
+ nonStopIncident(48)
+ }
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "Category for the event.
+
+ This category is intended to be used by the consumer to group events."
+ ::= { cpqRackEventInfo 5 }
+
+ cpqRackOtherEventCategory OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "A string defining other values for EventCategory.
+
+ It is empty unless EventCategory value is other(1)."
+ ::= { cpqRackEventInfo 6 }
+
+ cpqRackEventSubCategory OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "Sub-category for the event.
+
+ This sub-category is intended to be used by the consumer in conjunction
+ with the EventCategory to provide additional granularity to group events.
+ It is expected that additional values will be added that can be used with
+ other EventCategory values."
+ ::= { cpqRackEventInfo 7 }
+
+ cpqRackOtherEventSubCategory OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "A string defining other values for EventSubCategory.
+
+ It is empty unless EventSubCategory value is other(1)"
+ ::= { cpqRackEventInfo 8 }
+
+ cpqRackEventThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "Identifies the number of indications that need to occur as part of the
+ internal provider throttling configured for this event."
+ ::= { cpqRackEventInfo 9 }
+
+ cpqRackEventTimeWin OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "Identifies the time window during which the EventThreshold number of events
+ need to occur as part of the internal provider throttling configured for
+ this event.
+
+ Time is in minutes. 0 means any amount of time."
+ ::= { cpqRackEventInfo 10 }
+
+ cpqRackEventActualThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "Identifies the number of indications that have occurred to meet the
+ internal provider throttling configured for this event."
+ ::= { cpqRackEventInfo 11 }
+
+ cpqRackEventActualTimeWin OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "Identifies the time window during which the ActualEventThreshold number
+ of events have occurred to meet the internal provider throttling configured
+ for this event.
+
+ Time is in minutes. 0 means any amount of time."
+ ::= { cpqRackEventInfo 12 }
+
+ cpqRackEventProviderVersion OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..31))
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "The version of the provider generating this indication."
+ ::= { cpqRackEventInfo 13 }
+
+ cpqRackEventAlertingElementFormat OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(1),
+ other(2),
+ cimObjectPath(3)
+ }
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "The format of the AlertingManagedElement property is interpretable based
+ upon the value of this property.
+
+ Values are defined as:
+ 1 - unknown. The format is unknown or not meaningfully interpretable by a
+ CIM client application.
+ 2 - other. The format is defined by the value of the OtherAlertingElementFormat
+ property.
+ 3 - cimObjectPath. The format is a CIMObjectPath, specifying an instance in
+ the CIM Schema."
+ ::= { cpqRackEventInfo 14 }
+
+ cpqRackEventOtherAlertingElementFormat OBJECT-TYPE
+ SYNTAX OCTET STRING ( SIZE (0..256))
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "A string defining other values for AlertingElementFormat.
+
+ It is empty unless cpqRackEventAlertingElementFormat value is other(1)"
+ ::= { cpqRackEventInfo 15 }
+
+ cpqRackEventImpactedDomain OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(1),
+ cluster(2),
+ complex(3),
+ enclosure(4),
+ system(5),
+ partition(6)
+ }
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "ImpactedDomain is an enumerated value indicating the domain this event
+ affects."
+ ::= { cpqRackEventInfo 16 }
+
+ cpqRackEventComplexName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "The name of the complex."
+ ::= { cpqRackEventInfo 17 }
+
+ cpqRackEventPartitionId OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..12))
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "The Unique Identifier for the Partition.
+
+ The format of the partitionId will be of the form nparId:vparId."
+ ::= { cpqRackEventInfo 18 }
+
+ cpqRackEventTriggeringLogIDTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CpqRackEventTriggeringLogIDEntry
+ ACCESS not-accessible
+ STATUS optional
+ DESCRIPTION
+ "A table of rack of Low Level LOG IDs."
+ ::= { cpqRackEventInfo 19 }
+
+ cpqRackEventTriggeringLogIDEntry OBJECT-TYPE
+ SYNTAX CpqRackEventTriggeringLogIDEntry
+ ACCESS not-accessible
+ STATUS optional
+ DESCRIPTION
+ "The list of Low level LOG ID which were used to generate this event.
+
+ The format of the value contained in this array is defined using the
+ TriggeringLogIDFormat field."
+ INDEX { cpqRackEventTriggeringLogID }
+ ::= { cpqRackEventTriggeringLogIDTable 1 }
+
+ CpqRackEventTriggeringLogIDEntry ::= SEQUENCE {
+ cpqRackEventTriggeringLogID OCTET STRING
+ }
+
+ cpqRackEventTriggeringLogID OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (0..256))
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "A Low Lvevel LOG ID which were used to generate this event."
+ ::= {cpqRackEventTriggeringLogIDEntry 1 }
+
+
+ cpqRackEventTriggeringLogIDFormat OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(1),
+ cimObjectPath(2)
+ }
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "The format of the TriggeringLogID property which interpretable based upon
+ the value of this property.
+
+ Values are defined as:
+ 1 - unknown. The format is unknown or not meaningfully interpretable by a
+ CIM client application.
+ 2 - cimObjectPath. The format is a CIMObjectPath, with format specifying an
+ instance in the CIM Schema."
+ ::= { cpqRackEventInfo 20 }
+
+ cpqRackEventAlertType OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "The event alert type."
+ ::= { cpqRackEventInfo 21 }
+
+ cpqRackEventOtherAlertType OBJECT-TYPE
+ SYNTAX DisplayString ( SIZE (0..33))
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "The event other alert type.
+
+ It is empty unless cpqRackEventAlertType value is other."
+ ::= { cpqRackEventInfo 22 }
+
+ cpqRackEventProbableCause OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "An enumerated value that describes the probable cause of the error."
+ ::= { cpqRackEventInfo 23 }
+
+ cpqRackEventProbableCauseDescription OBJECT-TYPE
+ SYNTAX OCTET STRING ( SIZE (0..1024))
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "A free-form string describing the probable cause of the error."
+ ::= { cpqRackEventInfo 24 }
+
+ cpqRackEventPerceivedSeverity OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "An enumerated value that describes the severity of the Indication from
+ the point of view of the notifier."
+ ::= { cpqRackEventInfo 25 }
+
+ cpqRackEventOtherSeverity OBJECT-TYPE
+ SYNTAX DisplayString ( SIZE (0..64))
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "Other perceived severity.
+
+ It is empty unless cpqRackEventPerceivedSeverity value is other."
+ ::= { cpqRackEventInfo 26 }
+
+ cpqRackEventTrending OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "The event trending."
+ ::= { cpqRackEventInfo 27 }
+
+ cpqRackEventRecommendedActions OBJECT-TYPE
+ SYNTAX OCTET STRING ( SIZE (0..1024))
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "A free-form string describing recommended actions to take to resolve the error."
+ ::= { cpqRackEventInfo 28 }
+
+ cpqRackEventID OBJECT-TYPE
+ SYNTAX DisplayString ( SIZE (0..64))
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "An instrumentation or provider specific value that describes the underlying real-world event
+ represented by the indication related to the not-OK status."
+ ::= { cpqRackEventInfo 29 }
+
+ cpqRackEventTime OBJECT-TYPE
+ SYNTAX DisplayString ( SIZE (0..33))
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "The event time."
+ ::= { cpqRackEventInfo 30 }
+
+ cpqRackEventSystemCreationClassName OBJECT-TYPE
+ SYNTAX DisplayString ( SIZE (0..64))
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "The event system creation class name."
+ ::= { cpqRackEventInfo 31 }
+
+ cpqRackEventSystemName OBJECT-TYPE
+ SYNTAX DisplayString ( SIZE (0..64))
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "The event system name."
+ ::= { cpqRackEventInfo 32 }
+
+ cpqRackEventProviderName OBJECT-TYPE
+ SYNTAX DisplayString ( SIZE (0..64))
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "The name of the Provider that generated the indication related to the not-OK status."
+ ::= { cpqRackEventInfo 33 }
+
+
+
+-- ****************************************************************************
+-- Rack Information Trap Definitions
+-- =================================
+--
+-- The SNMP trap messages must not be bigger than 484 octets (bytes).
+--
+-- Trap support in an SNMP agent implementation is optional. An SNMP
+-- agent implementation may support all, some, or none of the traps.
+-- If traps are supported, The user should be provided with the option of
+-- disabling traps.
+-- **************************************************************************
+
+ cpqRackNameChanged TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackSerialNum,
+ cpqRackTrapSequenceNum }
+ DESCRIPTION
+ "Rack name has changed.
+
+ This trap signifies that an agent or utility has changed the name
+ of the rack. Each of the server blades in each of the enclosure
+ within the rack will be updated to reflect the new rack name.
+
+ It may take several minutes for the rack name change to be
+ propagated throughout the entire rack.
+
+ User Action: None."
+
+ --#TYPE "Rack name changed (22001)"
+ --#SUMMARY "The rack name has changed to %s."
+ --#ARGUMENTS {2}
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 99
+ --#STATE OPERATIONAL
+ --#SIMPLE_SEVERITY OK
+ --#HWSTATUS_CATEGORY OA
+ --#LIFECYCLE
+
+ ::= 22001
+
+ cpqRackEnclosureNameChanged TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackCommonEnclosureName,
+ cpqRackCommonEnclosureSerialNum,
+ cpqRackCommonEnclosureModel,
+ cpqRackCommonEnclosureSparePartNumber,
+ cpqRackCommonEnclosureTrapSequenceNum }
+ DESCRIPTION
+ "The enclosure name has changed.
+
+ This trap signifies that an agent or utility has changed the name
+ of an enclosure within the rack. Each of the components
+ within the rack will be updated to reflect the new enclosure name.
+
+ It may take several minutes for the enclosure name change to be
+ propagated throughout the entire enclosure.
+
+ User Action: None."
+
+ --#TYPE "Enclosure name changed (22002)"
+ --#SUMMARY "The enclosure name has changed to %s in rack %s."
+ --#ARGUMENTS {4, 2}
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 99
+ --#STATE OPERATIONAL
+ --#SIMPLE_SEVERITY OK
+ --#HWSTATUS_CATEGORY OA
+ --#LIFECYCLE
+
+ ::= 22002
+
+ cpqRackEnclosureRemoved TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackCommonEnclosureName,
+ cpqRackCommonEnclosureModel,
+ cpqRackCommonEnclosureSerialNum,
+ cpqRackCommonEnclosureSparePartNumber,
+ cpqRackCommonEnclosureTrapSequenceNum }
+ DESCRIPTION
+ "The enclosure has been removed.
+
+ This trap signifies that an enclosure has been removed from
+ the rack.
+
+ User Action: None."
+
+ --#TYPE "Enclosure removed (22003)"
+ --#SUMMARY "The enclosure %s has been removed from rack %s."
+ --#ARGUMENTS {4, 2}
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 99
+ --#STATE OPERATIONAL
+ --#SIMPLE_SEVERITY OK
+ --#HWSTATUS_CATEGORY OA
+ --#LIFECYCLE
+
+ ::= 22003
+
+ cpqRackEnclosureInserted TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackCommonEnclosureName,
+ cpqRackCommonEnclosureModel,
+ cpqRackCommonEnclosureSerialNum,
+ cpqRackCommonEnclosureSparePartNumber,
+ cpqRackCommonEnclosureTrapSequenceNum }
+ DESCRIPTION
+ "The enclosure has been inserted.
+
+ This trap signifies that an enclosure has been inserted into
+ the rack.
+
+ User Action: None."
+
+ --#TYPE "Enclosure inserted (22004)"
+ --#SUMMARY "The enclosure %s has been inserted into rack %s."
+ --#ARGUMENTS {4, 2}
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 99
+ --#STATE OPERATIONAL
+ --#SIMPLE_SEVERITY OK
+ --#HWSTATUS_CATEGORY OA
+ --#LIFECYCLE
+
+ ::= 22004
+
+ cpqRackEnclosureTempFailed TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackCommonEnclosureName,
+ cpqRackCommonEnclosureSerialNum,
+ cpqRackCommonEnclosureTempLocation,
+ cpqRackCommonEnclosureSparePartNumber,
+ cpqRackCommonEnclosureTrapSequenceNum }
+ DESCRIPTION
+ "The enclosure temperature status has been set to failed.
+
+ This trap signifies that a enclosure temperature sensor has
+ been tripped indicating an overheat condition.
+
+ User Action: Shutdown the enclosure and possibly the rack
+ as soon as possible. Ensure all fans are working properly and
+ that air flow in the rack has not been blocked."
+
+ --#TYPE "Enclosure temperature failed (22005)"
+ --#SUMMARY "The temperature sensor %s in enclosure %s in rack %s has been set to failed."
+ --#ARGUMENTS {6, 4, 2}
+ --#SEVERITY CRITICAL
+ --#TIMEINDEX 99
+ --#STATE NONOPERATIONAL
+ --#SIMPLE_SEVERITY CRITICAL
+ --#HWSTATUS_CATEGORY THERMAL
+ --#ACTION "Shutdown the enclosure and possibly the rack as soon as possible. Ensure all fans are working properly and that air flow in the rack has not been blocked."
+
+ ::= 22005
+
+ cpqRackEnclosureTempDegraded TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackCommonEnclosureName,
+ cpqRackCommonEnclosureSerialNum,
+ cpqRackCommonEnclosureTempLocation,
+ cpqRackCommonEnclosureSparePartNumber,
+ cpqRackCommonEnclosureTrapSequenceNum }
+ DESCRIPTION
+ "The enclosure temperature status has been set to degraded.
+
+ This trap signifies that an enclosure temperature sensor has
+ been tripped indicating a possible overheat condition.
+
+ User Action: Shutdown the enclosure and possibly the rack
+ as soon as possible. Ensure all fans are working properly and
+ that air flow in the rack has not been blocked."
+
+ --#TYPE "Enclosure temperature degraded (22006)"
+ --#SUMMARY "The temperature sensor %s in enclosure %s in rack %s has been set to degraded."
+ --#ARGUMENTS {6, 4, 2}
+ --#SEVERITY MAJOR
+ --#TIMEINDEX 99
+ --#STATE DEGRADED
+ --#SIMPLE_SEVERITY MAJOR
+ --#HWSTATUS_CATEGORY THERMAL
+ --#ACTION "Shutdown the enclosure and possibly the rack as soon as possible. Ensure all fans are working properly and that air flow in the rack has not been blocked."
+
+ ::= 22006
+
+ cpqRackEnclosureTempOk TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackCommonEnclosureName,
+ cpqRackCommonEnclosureSerialNum,
+ cpqRackCommonEnclosureTempLocation,
+ cpqRackCommonEnclosureSparePartNumber,
+ cpqRackCommonEnclosureTrapSequenceNum }
+ DESCRIPTION
+ "The enclosure temperature status has been set to ok.
+
+ This trap signifies that an enclosure temperature sensor has
+ returned to normal.
+
+ User Action: None."
+
+ --#TYPE "Enclosure temperature ok (22007)"
+ --#SUMMARY "The temperature sensor %s in enclosure %s in rack %s has been set to ok."
+ --#ARGUMENTS {6, 4, 2}
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 99
+ --#STATE OPERATIONAL
+ --#SIMPLE_SEVERITY OK
+ --#HWSTATUS_CATEGORY THERMAL
+
+ ::= 22007
+
+ cpqRackEnclosureFanFailed TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackCommonEnclosureName,
+ cpqRackCommonEnclosureSerialNum,
+ cpqRackCommonEnclosureFanLocation,
+ cpqRackCommonEnclosureFanSparePartNumber,
+ cpqRackCommonEnclosureTrapSequenceNum }
+ DESCRIPTION
+ "The enclosure fan status has been set to failed.
+
+ This trap signifies that an enclosure fan has failed and
+ no other fans in the redundant fan group are operating.
+ This may result in overheating of the enclosure.
+
+ User Action: Replace the fan as soon as possible."
+
+ --#TYPE "Enclosure fan failed (22008)"
+ --#SUMMARY "The fan %s in enclosure %s in rack %s has been set to failed."
+ --#ARGUMENTS {6, 4, 2}
+ --#SEVERITY CRITICAL
+ --#TIMEINDEX 99
+ --#STATE NONOPERATIONAL
+ --#SIMPLE_SEVERITY CRITICAL
+ --#HWSTATUS_CATEGORY THERMAL
+ --#ACTION "Replace the failed enclosure fan."
+
+ ::= 22008
+
+ cpqRackEnclosureFanDegraded TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackCommonEnclosureName,
+ cpqRackCommonEnclosureSerialNum,
+ cpqRackCommonEnclosureFanLocation,
+ cpqRackCommonEnclosureFanSparePartNumber,
+ cpqRackCommonEnclosureTrapSequenceNum }
+ DESCRIPTION
+ "The enclosure fan status has been set to degraded.
+
+ This trap signifies that an enclosure fan has failed but
+ other fans in the redundant fan group are still operating.
+ This may result in overheating of the enclosure.
+
+ User Action: Replace the fan as soon as possible."
+
+ --#TYPE "Enclosure fan degraded (22009)"
+ --#SUMMARY "The fan %s in enclosure %s in rack %s has been set to degraded."
+ --#ARGUMENTS {6, 4, 2}
+ --#SEVERITY MAJOR
+ --#TIMEINDEX 99
+ --#STATE DEGRADED
+ --#SIMPLE_SEVERITY MAJOR
+ --#HWSTATUS_CATEGORY THERMAL
+ --#ACTION "Replace the failing enclosure fan."
+
+ ::= 22009
+
+ cpqRackEnclosureFanOk TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackCommonEnclosureName,
+ cpqRackCommonEnclosureSerialNum,
+ cpqRackCommonEnclosureFanLocation,
+ cpqRackCommonEnclosureFanSparePartNumber,
+ cpqRackCommonEnclosureTrapSequenceNum }
+ DESCRIPTION
+ "The enclosure fan status has been set to ok.
+
+ This trap signifies that an enclosure fan has returned
+ to normal operation.
+
+ User Action: None."
+
+ --#TYPE "Enclosure fan ok (22010)"
+ --#SUMMARY "The fan %s in enclosure %s in rack %s has been set to ok."
+ --#ARGUMENTS {6, 4, 2}
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 99
+ --#STATE OPERATIONAL
+ --#SIMPLE_SEVERITY OK
+ --#HWSTATUS_CATEGORY THERMAL
+
+ ::= 22010
+
+
+ cpqRackEnclosureFanRemoved TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackCommonEnclosureName,
+ cpqRackCommonEnclosureSerialNum,
+ cpqRackCommonEnclosureFanLocation,
+ cpqRackCommonEnclosureFanSparePartNumber,
+ cpqRackCommonEnclosureTrapSequenceNum }
+ DESCRIPTION
+ "The enclosure fan has been removed.
+
+ User Action: None."
+
+ --#TYPE "Enclosure fan removed (22011)"
+ --#SUMMARY "The fan %s in enclosure %s in rack %s has been removed."
+ --#ARGUMENTS {6, 4, 2}
+ --#SEVERITY MINOR
+ --#TIMEINDEX 99
+ --#STATE DEGRADED
+ --#SIMPLE_SEVERITY MAJOR
+ --#HWSTATUS_CATEGORY THERMAL
+ --#LIFECYCLE
+
+ ::= 22011
+
+ cpqRackEnclosureFanInserted TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackCommonEnclosureName,
+ cpqRackCommonEnclosureSerialNum,
+ cpqRackCommonEnclosureFanLocation,
+ cpqRackCommonEnclosureFanSparePartNumber,
+ cpqRackCommonEnclosureTrapSequenceNum }
+ DESCRIPTION
+ "The enclosure fan has been inserted.
+
+ User Action: None."
+
+ --#TYPE "Enclosure fan inserted (22012)"
+ --#SUMMARY "The fan %s in enclosure %s in rack %s has been inserted."
+ --#ARGUMENTS {6, 4, 2}
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 99
+ --#STATE OPERATIONAL
+ --#SIMPLE_SEVERITY OK
+ --#HWSTATUS_CATEGORY THERMAL
+ --#LIFECYCLE
+
+ ::= 22012
+
+ cpqRackPowerSupplyFailed TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackPowerSupplyEnclosureName,
+ cpqRackPowerSupplySerialNum,
+ cpqRackPowerSupplyPosition,
+ cpqRackPowerSupplyFWRev,
+ cpqRackPowerSupplySparePartNumber,
+ cpqRackCommonEnclosureSerialNum,
+ cpqRackCommonEnclosureTrapSequenceNum }
+ DESCRIPTION
+ "The power supply status has been set to failed.
+
+ This trap signifies that a power supply has failed.
+
+ User Action: Replace the power supply as soon as possible."
+
+ --#TYPE "Rack power supply failed (22013)"
+ --#SUMMARY "The power supply %s in enclosure %s in rack %s has been set to failed."
+ --#ARGUMENTS {6, 4, 2}
+ --#SEVERITY CRITICAL
+ --#TIMEINDEX 99
+ --#STATE NONOPERATIONAL
+ --#SIMPLE_SEVERITY CRITICAL
+ --#HWSTATUS_CATEGORY POWER
+ --#ACTION "Replace the failed power supply."
+
+ ::= 22013
+
+ cpqRackPowerSupplyDegraded TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackPowerSupplyEnclosureName,
+ cpqRackPowerSupplySerialNum,
+ cpqRackPowerSupplyPosition,
+ cpqRackPowerSupplyFWRev,
+ cpqRackPowerSupplySparePartNumber,
+ cpqRackCommonEnclosureSerialNum,
+ cpqRackCommonEnclosureTrapSequenceNum }
+ DESCRIPTION
+ "The power supply status has been set to degraded.
+
+ This trap signifies that a power supply has degraded.
+
+ User Action: Replace the power supply as soon as possible."
+
+ --#TYPE "Rack power supply degraded (22014)"
+ --#SUMMARY "The power supply %s in enclosure %s in rack %s has been set to degraded."
+ --#ARGUMENTS {6, 4, 2}
+ --#SEVERITY MAJOR
+ --#TIMEINDEX 99
+ --#STATE DEGRADED
+ --#SIMPLE_SEVERITY MAJOR
+ --#HWSTATUS_CATEGORY POWER
+ --#ACTION "Replace the failing power supply."
+
+ ::= 22014
+
+ cpqRackPowerSupplyOk TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackPowerSupplyEnclosureName,
+ cpqRackPowerSupplySerialNum,
+ cpqRackPowerSupplyPosition,
+ cpqRackPowerSupplyFWRev,
+ cpqRackPowerSupplySparePartNumber,
+ cpqRackCommonEnclosureSerialNum,
+ cpqRackCommonEnclosureTrapSequenceNum }
+ DESCRIPTION
+ "The power supply status has been set to ok.
+
+ This trap signifies that a power supply has returned to normal
+ operation.
+
+ User Action: None."
+
+ --#TYPE "Rack power supply ok (22015)"
+ --#SUMMARY "The power supply %s in enclosure %s in rack %s has been set to ok."
+ --#ARGUMENTS {6, 4, 2}
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 99
+ --#STATE OPERATIONAL
+ --#SIMPLE_SEVERITY OK
+ --#HWSTATUS_CATEGORY POWER
+
+ ::= 22015
+
+ cpqRackPowerSupplyRemoved TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackPowerSupplyEnclosureName,
+ cpqRackPowerSupplySerialNum,
+ cpqRackPowerSupplyPosition,
+ cpqRackPowerSupplyFWRev,
+ cpqRackPowerSupplySparePartNumber,
+ cpqRackCommonEnclosureSerialNum,
+ cpqRackCommonEnclosureTrapSequenceNum }
+ DESCRIPTION
+ "The power supply has been removed.
+
+ User Action: None."
+
+ --#TYPE "Rack power supply removed (22016)"
+ --#SUMMARY "The power supply %s in enclosure %s in rack %s has been removed."
+ --#ARGUMENTS {6, 4, 2}
+ --#SEVERITY MINOR
+ --#TIMEINDEX 99
+ --#STATE DEGRADED
+ --#SIMPLE_SEVERITY MAJOR
+ --#HWSTATUS_CATEGORY POWER
+ --#LIFECYCLE
+
+ ::= 22016
+
+ cpqRackPowerSupplyInserted TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackPowerSupplyEnclosureName,
+ cpqRackPowerSupplySerialNum,
+ cpqRackPowerSupplyPosition,
+ cpqRackPowerSupplyFWRev,
+ cpqRackPowerSupplySparePartNumber,
+ cpqRackCommonEnclosureSerialNum,
+ cpqRackCommonEnclosureTrapSequenceNum }
+ DESCRIPTION
+ "The power supply has been inserted.
+
+ User Action: None."
+
+ --#TYPE "Rack power supply inserted (22017)"
+ --#SUMMARY "The power supply %s in enclosure %s in rack %s has been inserted."
+ --#ARGUMENTS {6, 4, 2}
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 99
+ --#STATE OPERATIONAL
+ --#SIMPLE_SEVERITY OK
+ --#HWSTATUS_CATEGORY POWER
+ --#LIFECYCLE
+
+ ::= 22017
+
+ cpqRackPowerSubsystemNotRedundant TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackPowerEnclosureName,
+ cpqRackCommonEnclosureSerialNum,
+ cpqRackCommonEnclosureTrapSequenceNum }
+ DESCRIPTION
+ "The rack power subsystem is no longer in a redundant state.
+
+ User Action: Replace any failed power supplies as soon as possible
+ to return the system to a redundant state."
+
+ --#TYPE "Rack power subsystem not redundant (22018)"
+ --#SUMMARY "The power subsystem in enclosure %s in rack %s is no longer redundant."
+ --#ARGUMENTS {4, 2}
+ --#SEVERITY MAJOR
+ --#TIMEINDEX 99
+ --#STATE DEGRADED
+ --#SIMPLE_SEVERITY MAJOR
+ --#HWSTATUS_CATEGORY POWER
+ --#ACTION "Replace any failed power supplies as soon as possible to return the system to a redundant state."
+ --#CLEAR_PRIOR_EVENTS true
+
+ ::= 22018
+
+ cpqRackPowerSubsystemLineVoltageProblem TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackPowerSupplyEnclosureName,
+ cpqRackPowerSupplyPosition,
+ cpqRackPowerSupplyFWRev,
+ cpqRackPowerSupplyInputLineStatus,
+ cpqRackPowerSupplySparePartNumber,
+ cpqRackCommonEnclosureSerialNum,
+ cpqRackCommonEnclosureTrapSequenceNum }
+ DESCRIPTION
+ "The rack power supply detected an input line voltage problem.
+
+ User Action: Check the power input for the power supply or replace
+ any failed power supplies as soon as possible."
+
+ --#TYPE "Rack power supply input voltage problem (22019)"
+ --#SUMMARY "The rack power supply detected an input line voltage problem in power supply %s, enclosure %s, rack %s."
+ --#ARGUMENTS {5, 4, 2}
+ --#SEVERITY MAJOR
+ --#TIMEINDEX 99
+ --#STATE DEGRADED
+ --#SIMPLE_SEVERITY MAJOR
+ --#HWSTATUS_CATEGORY POWER
+ --#ACTION "Check the power input for the power supply or replace any failed power supplies as soon as possible."
+
+ ::= 22019
+
+ cpqRackPowerSubsystemOverloadCondition TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackPowerEnclosureName,
+ cpqRackCommonEnclosureSparePartNumber,
+ cpqRackCommonEnclosureSerialNum,
+ cpqRackCommonEnclosureTrapSequenceNum }
+ DESCRIPTION
+ "The rack power subsystem overload condition.
+
+ User Action: Replace any failed power supplies as soon as possible
+ to return the system to a redundant state."
+
+ --#TYPE "Rack power subsystem overload condition (22020)"
+ --#SUMMARY "The power subsystem in enclosure %s in rack %s is in an overload condition."
+ --#ARGUMENTS {4, 2}
+ --#SEVERITY MAJOR
+ --#TIMEINDEX 99
+ --#STATE DEGRADED
+ --#SIMPLE_SEVERITY MAJOR
+ --#HWSTATUS_CATEGORY POWER
+ --#ACTION "Replace any failed power supplies as soon as possible."
+ --#CLEAR_PRIOR_EVENTS true
+ ::= 22020
+
+ cpqRackPowerShedAutoShutdown TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackServerBladeEnclosureName,
+ cpqRackServerBladePosition,
+ cpqRackServerBladeSparePartNumber,
+ cpqRackCommonEnclosureSerialNum,
+ cpqRackCommonEnclosureTrapSequenceNum }
+ DESCRIPTION
+ "Server shutdown due to power shedding.
+
+ The server blade was shutdown due to a lack of power.
+
+ User Action: Check power connections or add power supplies."
+
+ --#TYPE "Server shutdown due to power shedding (22021)"
+ --#SUMMARY "The server shutdown due to lack of power blade %s, in enclosure %s, in rack %s."
+ --#ARGUMENTS {5, 4, 2}
+ --#SEVERITY CRITICAL
+ --#TIMEINDEX 99
+ --#STATE NONOPERATIONAL
+ --#SIMPLE_SEVERITY CRITICAL
+ --#HWSTATUS_CATEGORY POWER
+ --#ACTION "Check the power connections for problems, then add power supplies if necessary."
+
+ ::= 22021
+
+ cpqRackServerPowerOnFailedNotRedundant TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackServerBladeEnclosureName,
+ cpqRackServerBladePosition,
+ cpqRackServerBladeSparePartNumber,
+ cpqRackCommonEnclosureSerialNum,
+ cpqRackCommonEnclosureTrapSequenceNum }
+ DESCRIPTION
+ "Server power on prevented to preserve redundancy.
+
+ There is not enough power to power on the server blade and
+ maintain redundancy for the other blades in the enclosure.
+
+ User Action: Check power connections or add power supplies."
+
+ --#TYPE "Server power on prevented to preserve redundancy (22022)"
+ --#SUMMARY "Server power on prevented to preserve redundancy in blade %s, in enclosure %s, in rack %s."
+ --#ARGUMENTS {5, 4, 2}
+ --#SEVERITY CRITICAL
+ --#TIMEINDEX 99
+ --#STATE NONOPERATIONAL
+ --#SIMPLE_SEVERITY CRITICAL
+ --#HWSTATUS_CATEGORY POWER
+ --#ACTION "Check the power connections for problems, then add power supplies if necessary."
+
+ ::= 22022
+
+ cpqRackServerPowerOnFailedNotEnoughPower TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackServerBladeEnclosureName,
+ cpqRackServerBladePosition,
+ cpqRackServerBladeSparePartNumber,
+ cpqRackCommonEnclosureSerialNum,
+ cpqRackCommonEnclosureTrapSequenceNum }
+ DESCRIPTION
+ "Inadequate power to power on.
+
+ There is not enough power to power on the server blade.
+
+ User Action: Check power connections or add power supplies."
+
+ --#TYPE "Inadequate power to power on (22023)"
+ --#SUMMARY "Inadequate power to power on blade %s, in enclosure %s, in rack %s."
+ --#ARGUMENTS {5, 4, 2}
+ --#SEVERITY CRITICAL
+ --#TIMEINDEX 99
+ --#STATE NONOPERATIONAL
+ --#SIMPLE_SEVERITY CRITICAL
+ --#HWSTATUS_CATEGORY DEVICEBAY
+ --#ACTION "Check the power connections for problems, then add power supplies if necessary."
+
+ ::= 22023
+
+ cpqRackServerPowerOnFailedEnclosureNotFound TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackServerBladeEnclosureName,
+ cpqRackServerBladePosition,
+ cpqRackServerBladeSparePartNumber,
+ cpqRackCommonEnclosureSerialNum,
+ cpqRackCommonEnclosureTrapSequenceNum }
+ DESCRIPTION
+ "Inadequate power to power on.
+
+ There is not enough power to power on the server blade. The
+ server enclosure micro-controller was not found.
+
+ User Action: Check server enclosure connections or add power supplies."
+
+ --#TYPE "Inadequate power to power on (22024)"
+ --#SUMMARY "Inadequate power to power on blade %s, in enclosure %s, in rack %s."
+ --#ARGUMENTS {5, 4, 2}
+ --#SEVERITY CRITICAL
+ --#TIMEINDEX 99
+ --#STATE NONOPERATIONAL
+ --#SIMPLE_SEVERITY CRITICAL
+ --#HWSTATUS_CATEGORY DEVICEBAY
+ --#ACTION "Check the server enclosure connections for problems, then add power supplies if necessary."
+
+ ::= 22024
+
+ cpqRackServerPowerOnFailedPowerChassisNotFound TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackServerBladeEnclosureName,
+ cpqRackServerBladePosition,
+ cpqRackServerBladeSparePartNumber,
+ cpqRackCommonEnclosureSerialNum,
+ cpqRackCommonEnclosureTrapSequenceNum }
+ DESCRIPTION
+ "Inadequate power to power on.
+
+ There is not enough power to power on the server blade. The
+ power enclosure micro-controller was not found.
+
+ User Action: Check power enclosure connections or add power supplies."
+
+ --#TYPE "Inadequate power to power on (22025)"
+ --#SUMMARY "Inadequate power to power on blade %s, in enclosure %s, in rack %s."
+ --#ARGUMENTS {5, 4, 2}
+ --#SEVERITY CRITICAL
+ --#TIMEINDEX 99
+ --#STATE NONOPERATIONAL
+ --#SIMPLE_SEVERITY CRITICAL
+ --#HWSTATUS_CATEGORY DEVICEBAY
+ --#ACTION "Check the power enclosure connections for problems, then add power supplies if necessary."
+
+ ::= 22025
+
+ cpqRackServerPowerOnManualOverride TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackServerBladeEnclosureName,
+ cpqRackServerBladePosition,
+ cpqRackServerBladeSparePartNumber,
+ cpqRackCommonEnclosureSerialNum,
+ cpqRackCommonEnclosureTrapSequenceNum }
+ DESCRIPTION
+ "Server power on via manual override.
+
+ The server blade was powered on by a manual override.
+
+ User Action: None."
+
+ --#TYPE "Server power on via manual override (22026)"
+ --#SUMMARY "Server power on via manual override on blade %s, in enclosure %s, in rack %s."
+ --#ARGUMENTS {5, 4, 2}
+ --#SEVERITY MAJOR
+ --#TIMEINDEX 99
+ --#STATE DEGRADED
+ --#SIMPLE_SEVERITY MAJOR
+ --#HWSTATUS_CATEGORY DEVICEBAY
+
+ ::= 22026
+
+ cpqRackFuseOpen TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackCommonEnclosureName,
+ cpqRackCommonEnclosureFuseLocation,
+ cpqRackCommonEnclosureSparePartNumber,
+ cpqRackCommonEnclosureSerialNum,
+ cpqRackCommonEnclosureTrapSequenceNum }
+ DESCRIPTION
+ "Fuse open.
+
+ The fuse has been tripped.
+
+ User Action: Check enclosure and / or blade power connections and
+ reset the fuse."
+
+ --#TYPE "Fuse open (22027)"
+ --#SUMMARY "Fuse open fuse %s, in enclosure %s, in rack %s."
+ --#ARGUMENTS {5, 4, 2}
+ --#SEVERITY MAJOR
+ --#TIMEINDEX 99
+ --#STATE DEGRADED
+ --#SIMPLE_SEVERITY MAJOR
+ --#HWSTATUS_CATEGORY ENCLOSURE
+ --#ACTION "Check the enclosure and blade power connections, then reset the fuse."
+
+ ::= 22027
+
+
+ cpqRackServerBladeRemoved TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackServerBladeEnclosureName,
+ cpqRackServerBladeName,
+ cpqRackServerBladePosition,
+ cpqRackServerBladeSparePartNumber,
+ cpqRackCommonEnclosureSerialNum,
+ cpqRackCommonEnclosureTrapSequenceNum }
+ DESCRIPTION
+ "Server blade removed.
+
+ The server blade has been removed from the enclosure.
+
+ User Action: None."
+
+ --#TYPE "Server blade removed (22028)"
+ --#SUMMARY "Server blade %s removed from position %s, in enclosure %s, in rack %s."
+ --#ARGUMENTS {5, 6, 4, 2}
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 99
+ --#STATE OPERATIONAL
+ --#SIMPLE_SEVERITY OK
+ --#HWSTATUS_CATEGORY DEVICEBAY
+ --#LIFECYCLE
+
+ ::= 22028
+
+ cpqRackServerBladeInserted TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackServerBladeEnclosureName,
+ cpqRackServerBladeName,
+ cpqRackServerBladePosition,
+ cpqRackServerBladeSparePartNumber,
+ cpqRackCommonEnclosureSerialNum,
+ cpqRackCommonEnclosureTrapSequenceNum }
+ DESCRIPTION
+ "Server blade inserted.
+
+ The server blade has been inserted into the enclosure.
+
+ User Action: None."
+
+ --#TYPE "Server blade inserted (22029)"
+ --#SUMMARY "Server blade %s inserted into position %s, in enclosure %s, in rack %s."
+ --#ARGUMENTS {5, 6, 4, 2}
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 99
+ --#STATE OPERATIONAL
+ --#SIMPLE_SEVERITY OK
+ --#HWSTATUS_CATEGORY DEVICEBAY
+ --#LIFECYCLE
+
+ ::= 22029
+
+ cpqRackPowerChassisNotLoadBalanced TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackCommonEnclosureName,
+ cpqRackCommonEnclosureSerialNum,
+ cpqRackCommonEnclosureSparePartNumber,
+ cpqRackCommonEnclosureTrapSequenceNum }
+ DESCRIPTION
+ "Power subsystem not load balanced.
+
+ The power subsystem is out of balance for this power enclosure.
+
+ User Action: Check the power enclosure and power supplies. Replace
+ any failed or degraded power supplies. Add additional power supplies
+ if needed."
+
+ --#TYPE "Power subsystem not load balanced (22030)"
+ --#SUMMARY "Power subsystem not load balanced in enclosure %s, in rack %s."
+ --#ARGUMENTS {4, 2}
+ --#SEVERITY MAJOR
+ --#TIMEINDEX 99
+ --#STATE DEGRADED
+ --#SIMPLE_SEVERITY MAJOR
+ --#HWSTATUS_CATEGORY POWER
+ --#ACTION "Check the power enclosure and power supplies. Replace any failed or degraded power supplies. Add additional power supplies if needed."
+
+ ::= 22030
+
+ cpqRackPowerChassisDcPowerProblem TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackCommonEnclosureName,
+ cpqRackCommonEnclosureSerialNum,
+ cpqRackCommonEnclosureSparePartNumber,
+ cpqRackCommonEnclosureTrapSequenceNum }
+ DESCRIPTION
+ "Power subsystem DC power problem.
+
+ There is a power subsystem DC power problem for this power enclosure.
+
+ User Action: Check the power enclosure and power supplies. Replace
+ any failed or degraded power supplies."
+
+ --#TYPE "Power subsystem DC power problem (22031)"
+ --#SUMMARY "Power subsystem DC power problem in enclosure %s, in rack %s."
+ --#ARGUMENTS {4, 2}
+ --#SEVERITY MAJOR
+ --#TIMEINDEX 99
+ --#STATE DEGRADED
+ --#SIMPLE_SEVERITY MAJOR
+ --#HWSTATUS_CATEGORY POWER
+ --#ACTION "Check the power enclosure and power supplies. Replace any failed or degraded power supplies."
+
+ ::= 22031
+
+ cpqRackPowerChassisAcFacilityPowerExceeded TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackCommonEnclosureName,
+ cpqRackCommonEnclosureSerialNum,
+ cpqRackCommonEnclosureSparePartNumber,
+ cpqRackCommonEnclosureTrapSequenceNum }
+ DESCRIPTION
+ "Power subsystem AC facility input power exceeded.
+
+ There is a power subsystem Power subsystem AC facility input power
+ exceeded for this power enclosure.
+
+ User Action: Check the power enclosure and power supplies. Replace
+ any failed or degraded power supplies."
+
+ --#TYPE "Power subsystem AC facility input power exceeded (22032)"
+ --#SUMMARY "Power subsystem AC facility input power exceeded in enclosure %s, in rack %s."
+ --#ARGUMENTS {4, 2}
+ --#SEVERITY MAJOR
+ --#TIMEINDEX 99
+ --#STATE DEGRADED
+ --#SIMPLE_SEVERITY MAJOR
+ --#HWSTATUS_CATEGORY POWER
+ --#ACTION "Check the power enclosure and power supplies. Replace any failed or degraded power supplies."
+
+ ::= 22032
+
+
+
+ cpqRackPowerUnknownPowerConsumption TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackCommonEnclosureSerialNum,
+ cpqRackCommonEnclosureTrapSequenceNum }
+ DESCRIPTION
+ "Unknown power consumption.
+
+ There is an unknown power consumer drawing power.
+
+ User Action: Check the power enclosure and power supplies. Replace
+ any failed or degraded power supplies."
+
+ --#TYPE "Unknown power consumption (22033)"
+ --#SUMMARY "Unknown power consumption in rack %s."
+ --#ARGUMENTS {2}
+ --#SEVERITY MAJOR
+ --#TIMEINDEX 99
+ --#STATE DEGRADED
+ --#SIMPLE_SEVERITY MAJOR
+ --#HWSTATUS_CATEGORY POWER
+ --#ACTION "Check the power enclosure and power supplies. Replace any failed or degraded power supplies."
+
+ ::= 22033
+
+ cpqRackPowerChassisLoadBalancingWireMissing TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackCommonEnclosureName,
+ cpqRackCommonEnclosureSerialNum,
+ cpqRackCommonEnclosureSparePartNumber,
+ cpqRackCommonEnclosureTrapSequenceNum }
+ DESCRIPTION
+ "Power subsystem load balancing wire missing.
+
+ The power subsystem load balancing wire missing.
+
+ User Action: Connect the load balancing wire."
+
+ --#TYPE "Power subsystem load balancing wire missing (22034)"
+ --#SUMMARY "Power subsystem load balancing wire missing for enclosure %s, in rack %s."
+ --#ARGUMENTS {4, 2}
+ --#SEVERITY MAJOR
+ --#TIMEINDEX 99
+ --#STATE DEGRADED
+ --#SIMPLE_SEVERITY MAJOR
+ --#HWSTATUS_CATEGORY POWER
+ --#ACTION "Connect the load balancing wire."
+
+ ::= 22034
+
+ cpqRackPowerChassisTooManyPowerChassis TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackCommonEnclosureName,
+ cpqRackCommonEnclosureSerialNum,
+ cpqRackCommonEnclosureTrapSequenceNum }
+ DESCRIPTION
+ "Power subsystem has too may power enclosures.
+
+ The maximum number of power enclosures has been exceeded.
+
+ User Action: Remove the extra power enclosure."
+
+ --#TYPE "Power subsystem has too may power enclosures (22035)"
+ --#SUMMARY "Power subsystem has too may power enclosures %s, in rack %s."
+ --#ARGUMENTS {4, 2}
+ --#SEVERITY MAJOR
+ --#TIMEINDEX 99
+ --#STATE DEGRADED
+ --#SIMPLE_SEVERITY MAJOR
+ --#HWSTATUS_CATEGORY POWER
+ --#ACTION "Remove the extra power enclosure."
+
+ ::= 22035
+
+ cpqRackPowerChassisConfigError TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackCommonEnclosureName,
+ cpqRackCommonEnclosureSerialNum,
+ cpqRackCommonEnclosureSparePartNumber,
+ cpqRackCommonEnclosureTrapSequenceNum }
+ DESCRIPTION
+ "Power subsystem improperly configured.
+
+ The power subsystem has been improperly configured.
+
+ User Action: Check the cabling of the power enclosure."
+
+ --#TYPE "Power subsystem improperly configured (22036)"
+ --#SUMMARY "Power subsystem has been improperly configured in enclosure %s, in rack %s."
+ --#ARGUMENTS {4, 2}
+ --#SEVERITY MAJOR
+ --#TIMEINDEX 99
+ --#STATE DEGRADED
+ --#SIMPLE_SEVERITY MAJOR
+ --#HWSTATUS_CATEGORY POWER
+ --#ACTION "Check the cabling of the power enclosure."
+
+ ::= 22036
+
+ cpqRackEnclosureManagerDegraded TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackCommonEnclosureName,
+ cpqRackCommonEnclosureSerialNum,
+ cpqRackCommonEnclosureManagerLocation,
+ cpqRackCommonEnclosureManagerSparePartNumber,
+ cpqRackCommonEnclosureManagerSerialNum,
+ cpqRackCommonEnclosureTrapSequenceNum }
+ DESCRIPTION
+ "The Onboard Administrator or other management processor status has been set to degraded.
+
+ This trap signifies that either the Onboard Administrator(s) or its component(s) has degraded/failed,
+ their firmware versions are mismatched, or one or more management processors is in a non-optimal operating state.
+
+ User Action: For C-Class enclosures, please refer to the Onboard Administrator SYSLOG.
+ For all the others please refer to product documentation for possible corrective actions"
+
+ --#TYPE "Enclosure manager degraded (22037)"
+ --#SUMMARY "The enclosure %s manager in rack %s has been set to degraded."
+ --#ARGUMENTS {4, 2}
+ --#SEVERITY MAJOR
+ --#TIMEINDEX 99
+ --#STATE DEGRADED
+ --#SIMPLE_SEVERITY MAJOR
+ --#HWSTATUS_CATEGORY OA
+ --#ACTION "The following conditions can result in a degraded Onboard Administrator (OA): 1) one OA failed but the second OA is still operating, 2) one or more OAs is in a non-optimal operating state, 3) a firmware revision mismatch occurred between the primary and secondary OAs, or 4) OA RTC battery is low. To determine what caused the issue, see the OA and check the logs for more information. If a firmware mismatch occurred, use the OA UI or CLI (UPDATE IMAGE SYNC command) to resynchronize the firmware on the OAs. If OA RTC battery is found to be low, replace battery."
+
+
+ ::= 22037
+
+ cpqRackEnclosureManagerOk TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackCommonEnclosureName,
+ cpqRackCommonEnclosureSerialNum,
+ cpqRackCommonEnclosureManagerLocation,
+ cpqRackCommonEnclosureManagerSparePartNumber,
+ cpqRackCommonEnclosureManagerSerialNum,
+ cpqRackCommonEnclosureTrapSequenceNum }
+ DESCRIPTION
+ "The Onboard Administrator or other management processor's status has been set to ok.
+
+ This trap signifies that an Onboard Administrator or other management processor has returned
+ to normal operation.
+
+ User Action: None."
+
+ --#TYPE "Onboard or management processor ok (22038)"
+ --#SUMMARY "The Onboard Administrator or management processor %s in rack %s has been set to ok."
+ --#ARGUMENTS {4, 2}
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 99
+ --#STATE OPERATIONAL
+ --#SIMPLE_SEVERITY OK
+ --#HWSTATUS_CATEGORY OA
+
+ ::= 22038
+
+ cpqRackEnclosureManagerRemoved TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackCommonEnclosureName,
+ cpqRackCommonEnclosureSerialNum,
+ cpqRackCommonEnclosureManagerLocation,
+ cpqRackCommonEnclosureManagerSparePartNumber,
+ cpqRackCommonEnclosureManagerSerialNum,
+ cpqRackCommonEnclosureTrapSequenceNum }
+ DESCRIPTION
+ "The Onboard Administrator has been removed.
+
+ User Action: None."
+
+ --#TYPE "Onboard Administrator removed (22039)"
+ --#SUMMARY "The Onboard Administrator %s in rack %s has been removed."
+ --#ARGUMENTS {4, 2}
+ --#SEVERITY MINOR
+ --#TIMEINDEX 99
+ --#STATE DEGRADED
+ --#SIMPLE_SEVERITY MAJOR
+ --#HWSTATUS_CATEGORY OA
+ --#LIFECYCLE
+
+ ::= 22039
+
+ cpqRackEnclosureManagerInserted TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackCommonEnclosureName,
+ cpqRackCommonEnclosureSerialNum,
+ cpqRackCommonEnclosureManagerLocation,
+ cpqRackCommonEnclosureManagerSparePartNumber,
+ cpqRackCommonEnclosureManagerSerialNum,
+ cpqRackCommonEnclosureTrapSequenceNum }
+ DESCRIPTION
+ "The Onboard Administrator or other management processor has been inserted.
+
+ User Action: None."
+
+ --#TYPE "Onboard Administrator or other management processor inserted (22040)"
+ --#SUMMARY "The Onboard Administrator or other management processor %s in rack %s has been inserted."
+ --#ARGUMENTS {4, 2}
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 99
+ --#STATE OPERATIONAL
+ --#SIMPLE_SEVERITY OK
+ --#HWSTATUS_CATEGORY OA
+ --#LIFECYCLE
+
+ ::= 22040
+
+ cpqRackManagerPrimaryRole TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackCommonEnclosureName,
+ cpqRackCommonEnclosureSerialNum,
+ cpqRackCommonEnclosureManagerLocation,
+ cpqRackCommonEnclosureManagerSparePartNumber,
+ cpqRackCommonEnclosureManagerSerialNum,
+ cpqRackCommonEnclosureTrapSequenceNum }
+ DESCRIPTION
+ "The Onboard Administrator or other management processor has taken the role of primary.
+
+ User Action: None."
+
+ --#TYPE "Onboard Administrator or other management processor has taken the role of primary (UID)."
+ --#SUMMARY "Onboard Administrator or other management processor has taken the role of primary, in enclosure %s, in rack %s."
+ --#ARGUMENTS {4, 2}
+ --#SEVERITY MAJOR
+ --#TIMEINDEX 99
+ --#STATE OPERATIONAL
+ --#SIMPLE_SEVERITY MAJOR
+ --#HWSTATUS_CATEGORY OA
+
+ ::= 22041
+
+ cpqRackServerBladeEKeyingFailed TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackServerBladeEnclosureName,
+ cpqRackServerBladeName,
+ cpqRackServerBladePosition,
+ cpqRackServerBladeSparePartNumber,
+ cpqRackCommonEnclosureSerialNum,
+ cpqRackCommonEnclosureTrapSequenceNum }
+ DESCRIPTION
+ "The server blade e-keying has failed.
+
+ This trap signifies that a server blade e-keying has failed and
+ there is a port mapping problem between a server mezz card
+ and the interconnect.
+
+ User Action: Reconfigure server blade mezz cards."
+
+ --#TYPE "Server Blade e-keying failed (22042)"
+ --#SUMMARY "Server blade %s e-keying failed in position %s, in enclosure %s, in rack %s."
+ --#ARGUMENTS {5, 6, 4, 2}
+ --#SEVERITY MAJOR
+ --#TIMEINDEX 99
+ --#STATE DEGRADED
+ --#SIMPLE_SEVERITY MAJOR
+ --#HWSTATUS_CATEGORY DEVICEBAY
+ --#ACTION "Reconfigure the server blade mezz cards."
+
+ ::= 22042
+
+ cpqRackServerBladeEKeyingOK TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackServerBladeEnclosureName,
+ cpqRackServerBladeName,
+ cpqRackServerBladePosition,
+ cpqRackServerBladeSparePartNumber,
+ cpqRackCommonEnclosureSerialNum,
+ cpqRackCommonEnclosureTrapSequenceNum }
+ DESCRIPTION
+ "The server blade e-keying is ok.
+
+ This trap signifies that a server blade e-keying has returned to
+ normal operation.
+
+ User Action: None."
+
+ --#TYPE "Server Blade e-keying ok (22043)"
+ --#SUMMARY "Server blade %s e-keying is ok in position %s, in enclosure %s, in rack %s."
+ --#ARGUMENTS {5, 6, 4, 2}
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 99
+ --#STATE OPERATIONAL
+ --#SIMPLE_SEVERITY OK
+ --#HWSTATUS_CATEGORY DEVICEBAY
+
+ ::= 22043
+
+ cpqRackNetConnectorRemoved TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackNetConnectorEnclosureName,
+ cpqRackNetConnectorName,
+ cpqRackNetConnectorLocation,
+ cpqRackNetConnectorSparePartNumber,
+ cpqRackCommonEnclosureSerialNum,
+ cpqRackCommonEnclosureTrapSequenceNum }
+ DESCRIPTION
+ "Interconnect removed.
+
+ The interconnect has been removed from the enclosure.
+
+ User Action: None."
+
+ --#TYPE "Interconnect removed (22044)"
+ --#SUMMARY "Interconnect %s removed from position %s, in enclosure %s, in rack %s."
+ --#ARGUMENTS {5, 6, 4, 2}
+ --#SEVERITY MAJOR
+ --#TIMEINDEX 99
+ --#STATE DEGRADED
+ --#SIMPLE_SEVERITY MAJOR
+ --#HWSTATUS_CATEGORY INTERCONNECTBAY
+ --#LIFECYCLE
+
+ ::= 22044
+
+ cpqRackNetConnectorInserted TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackNetConnectorEnclosureName,
+ cpqRackNetConnectorName,
+ cpqRackNetConnectorLocation,
+ cpqRackNetConnectorSparePartNumber,
+ cpqRackCommonEnclosureSerialNum,
+ cpqRackCommonEnclosureTrapSequenceNum }
+ DESCRIPTION
+ "Interconnect inserted.
+
+ The interconnect has been inserted into the enclosure.
+
+ User Action: None."
+
+ --#TYPE "Interconnect inserted (22045)"
+ --#SUMMARY "Interconnect %s inserted into position %s, in enclosure %s, in rack %s."
+ --#ARGUMENTS {5, 6, 4, 2}
+ --#SEVERITY MAJOR
+ --#TIMEINDEX 99
+ --#STATE DEGRADED
+ --#SIMPLE_SEVERITY MAJOR
+ --#HWSTATUS_CATEGORY INTERCONNECTBAY
+ --#LIFECYCLE
+
+ ::= 22045
+
+ cpqRackNetConnectorFailed TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackNetConnectorEnclosureName,
+ cpqRackNetConnectorName,
+ cpqRackNetConnectorLocation,
+ cpqRackNetConnectorSparePartNumber,
+ cpqRackCommonEnclosureSerialNum,
+ cpqRackCommonEnclosureTrapSequenceNum }
+ DESCRIPTION
+ "The interconnect status has been set to failed.
+
+ This trap signifies that a interconnect has failed.
+
+ User Action: Replace the interconnect as soon as possible."
+
+ --#TYPE "Interconnect failed (22046)"
+ --#SUMMARY "Interconnect %s failed in position %s, in enclosure %s, in rack %s."
+ --#ARGUMENTS {5, 6, 4, 2}
+ --#SEVERITY CRITICAL
+ --#TIMEINDEX 99
+ --#STATE NONOPERATIONAL
+ --#SIMPLE_SEVERITY CRITICAL
+ --#HWSTATUS_CATEGORY INTERCONNECTBAY
+ --#ACTION "Refer to the OA and the status diagnostics reported for the interconnect."
+
+ ::= 22046
+
+ cpqRackNetConnectorDegraded TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackNetConnectorEnclosureName,
+ cpqRackNetConnectorName,
+ cpqRackNetConnectorLocation,
+ cpqRackNetConnectorSparePartNumber,
+ cpqRackCommonEnclosureSerialNum,
+ cpqRackCommonEnclosureTrapSequenceNum }
+ DESCRIPTION
+ "The interconnect status has been set to degraded.
+
+ This trap signifies that a interconnect has degraded.
+
+ User Action: Refer to the OA and the status diagnostics reported for the interconnect."
+
+ --#TYPE "Interconnect degraded (22047)"
+ --#SUMMARY "Interconnect %s degraded in position %s, in enclosure %s, in rack %s."
+ --#ARGUMENTS {5, 6, 4, 2}
+ --#SEVERITY MAJOR
+ --#TIMEINDEX 99
+ --#STATE DEGRADED
+ --#SIMPLE_SEVERITY MAJOR
+ --#HWSTATUS_CATEGORY INTERCONNECTBAY
+ --#ACTION "Refer to the OA and the status diagnostics reported for the interconnect."
+
+ ::= 22047
+
+ cpqRackNetConnectorOk TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackNetConnectorEnclosureName,
+ cpqRackNetConnectorName,
+ cpqRackNetConnectorLocation,
+ cpqRackNetConnectorSparePartNumber,
+ cpqRackCommonEnclosureSerialNum,
+ cpqRackCommonEnclosureTrapSequenceNum }
+ DESCRIPTION
+ "The interconnect status has been set to ok.
+
+ This trap signifies that a interconnect has returned to
+ normal operation.
+
+ User Action: None."
+
+ --#TYPE "Interconnect ok (22048)"
+ --#SUMMARY "Interconnect %s ok in position %s, in enclosure %s, in rack %s."
+ --#ARGUMENTS {5, 6, 4, 2}
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 99
+ --#STATE OPERATIONAL
+ --#SIMPLE_SEVERITY OK
+ --#HWSTATUS_CATEGORY INTERCONNECTBAY
+
+ ::= 22048
+
+ cpqRackServerBladeToLowPower TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackServerBladeEnclosureName,
+ cpqRackServerBladeName,
+ cpqRackServerBladePosition,
+ cpqRackServerBladeSparePartNumber,
+ cpqRackCommonEnclosureSerialNum,
+ cpqRackCommonEnclosureTrapSequenceNum }
+ DESCRIPTION
+ "The server blade requested to low power.
+
+ User Action: None."
+
+ --#TYPE "Server Blade requested to low power (22049)"
+ --#SUMMARY "Server blade %s requested to low power in position %s, in enclosure %s, in rack %s."
+ --#ARGUMENTS {5, 6, 4, 2}
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 99
+ --#STATE OPERATIONAL
+ --#SIMPLE_SEVERITY OK
+ --#HWSTATUS_CATEGORY DEVICEBAY
+
+ ::= 22049
+
+ cpqRackServerBladeRemoved2 TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackServerBladeEnclosureName,
+ cpqRackServerBladeName,
+ cpqRackServerBladePosition,
+ cpqRackServerBladeSparePartNumber,
+ cpqRackCommonEnclosureSerialNum,
+ cpqRackServerBladeSerialNum,
+ cpqRackServerBladeUid,
+ cpqRackCommonEnclosureTrapSequenceNum }
+ DESCRIPTION
+ "Server blade removed.
+
+ The server blade has been removed from the enclosure.
+
+ User Action: None."
+
+ --#TYPE "Server blade removed (22050)"
+ --#SUMMARY "Server blade %s removed from position %s, in enclosure %s, in rack %s."
+ --#ARGUMENTS {5, 6, 4, 2}
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 99
+ --#STATE OPERATIONAL
+ --#SIMPLE_SEVERITY OK
+ --#HWSTATUS_CATEGORY DEVICEBAY
+ --#LIFECYCLE
+
+ ::= 22050
+
+ cpqRackServerBladeInserted2 TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackServerBladeEnclosureName,
+ cpqRackServerBladeName,
+ cpqRackServerBladePosition,
+ cpqRackServerBladeSparePartNumber,
+ cpqRackCommonEnclosureSerialNum,
+ cpqRackServerBladeSerialNum,
+ cpqRackServerBladeUid,
+ cpqRackCommonEnclosureTrapSequenceNum }
+ DESCRIPTION
+ "Server blade inserted.
+
+ The server blade has been inserted into the enclosure.
+
+ User Action: None."
+
+ --#TYPE "Server blade inserted (22051)"
+ --#SUMMARY "Server blade %s inserted into position %s, in enclosure %s, in rack %s."
+ --#ARGUMENTS {5, 6, 4, 2}
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 99
+ --#STATE OPERATIONAL
+ --#SIMPLE_SEVERITY OK
+ --#HWSTATUS_CATEGORY DEVICEBAY
+ --#LIFECYCLE
+
+ ::= 22051
+
+ cpqRackServerBladeStatusRepaired TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackServerBladeEnclosureName,
+ cpqRackServerBladeName,
+ cpqRackServerBladeProductId,
+ cpqRackServerBladePosition,
+ cpqRackServerBladeSparePartNumber,
+ cpqRackCommonEnclosureSerialNum,
+ cpqRackServerBladeSerialNum,
+ cpqRackServerBladeUid,
+ cpqRackCommonEnclosureTrapSequenceNum }
+ DESCRIPTION
+ "Server blade repaired.
+
+ The server blade status has changed to OK.
+
+ User Action: None."
+
+ --#TYPE "Server blade repaired (22052)"
+ --#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s status has changed to OK."
+ --#ARGUMENTS {5, 7, 4, 2}
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 99
+ --#STATE OPERATIONAL
+ --#SIMPLE_SEVERITY OK
+ --#HWSTATUS_CATEGORY DEVICEBAY
+
+ ::= 22052
+
+cpqRackServerBladeStatusDegraded TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackServerBladeEnclosureName,
+ cpqRackServerBladeName,
+ cpqRackServerBladeProductId,
+ cpqRackServerBladePosition,
+ cpqRackServerBladeSparePartNumber,
+ cpqRackCommonEnclosureSerialNum,
+ cpqRackServerBladeSerialNum,
+ cpqRackServerBladeUid,
+ cpqRackServerBladeFaultMajor,
+ cpqRackServerBladeFaultMinor,
+ cpqRackServerBladeFaultDiagnosticString,
+ cpqRackCommonEnclosureTrapSequenceNum }
+ DESCRIPTION
+ "Server blade health status Degraded.
+
+ The server blade health status has changed to Degraded.
+
+ User Action: Check blade server and enclosure SYSLOG."
+
+ --#TYPE "Server blade health status degraded (22053)"
+ --#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s health status has changed to degraded. Reason: %s."
+ --#ARGUMENTS {5, 7, 4, 2, 14}
+ --#SEVERITY MAJOR
+ --#TIMEINDEX 99
+ --#STATE OPERATIONAL
+ --#SIMPLE_SEVERITY MAJOR
+ --#HWSTATUS_CATEGORY DEVICEBAY
+ --#ACTION "Check the blade server and enclosure SYSLOG."
+
+ ::= 22053
+
+cpqRackServerBladeStatusCritical TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackServerBladeEnclosureName,
+ cpqRackServerBladeName,
+ cpqRackServerBladeProductId,
+ cpqRackServerBladePosition,
+ cpqRackServerBladeSparePartNumber,
+ cpqRackCommonEnclosureSerialNum,
+ cpqRackServerBladeSerialNum,
+ cpqRackServerBladeUid,
+ cpqRackServerBladeFaultMajor,
+ cpqRackServerBladeFaultMinor,
+ cpqRackServerBladeFaultDiagnosticString,
+ cpqRackCommonEnclosureTrapSequenceNum }
+ DESCRIPTION
+ "Server blade health status Critical.
+
+ The server blade health status has changed to Critical.
+
+ User Action: Check blade server and enclosure SYSLOG."
+
+ --#TYPE "Server blade health status critical (22054)"
+ --#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s health status has changed to critical. Reason: %s."
+ --#ARGUMENTS {5, 7, 4, 2, 14}
+ --#SEVERITY CRITICAL
+ --#TIMEINDEX 99
+ --#STATE OPERATIONAL
+ --#SIMPLE_SEVERITY CRITICAL
+ --#HWSTATUS_CATEGORY DEVICEBAY
+ --#ACTION "Check the blade server and enclosure SYSLOG."
+
+ ::= 22054
+
+cpqRackServerBladeGrpCapTimeout TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackServerBladeEnclosureName,
+ cpqRackServerBladeName,
+ cpqRackServerBladePosition,
+ cpqRackServerBladeSparePartNumber,
+ cpqRackCommonEnclosureSerialNum,
+ cpqRackCommonEnclosureTrapSequenceNum }
+ DESCRIPTION
+ "The server blade is not responding to the group capper.
+
+ The server blade is not responding to capping requests from the enclosure group capper
+
+ User Action: Reset the iLO management processor."
+
+ --#TYPE "Server blade not responding to group capping requests (22055)"
+ --#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s is not responding to requests from the enclosure group capper."
+ --#ARGUMENTS {5, 6, 4, 2}
+ --#SEVERITY CRITICAL
+ --#TIMEINDEX 99
+ --#STATE DEGRADED
+ --#SIMPLE_SEVERITY CRITICAL
+ --#HWSTATUS_CATEGORY DEVICEBAY
+ --#ACTION "Reset the iLO management processor."
+
+ ::= 22055
+
+ cpqRackServerBladeUnexpectedShutdown TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackServerBladeEnclosureName,
+ cpqRackServerBladeName,
+ cpqRackServerBladePosition,
+ cpqRackServerBladeSparePartNumber,
+ cpqRackCommonEnclosureSerialNum,
+ cpqRackServerBladeSerialNum,
+ cpqRackServerBladeUid,
+ cpqRackCommonEnclosureTrapSequenceNum }
+ DESCRIPTION
+ "Server blade shutdown unexpectadly.
+
+ An unexpected shutdown event has occurred for this server blade.
+
+ User Action: Check blade server and enclosure SYSLOG."
+
+ --#TYPE "Server blade unexpected shutdown (22056)"
+ --#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s has unexpectedly shutdown."
+ --#ARGUMENTS {5, 6, 4, 2}
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 99
+ --#STATE OPERATIONAL
+ --#SIMPLE_SEVERITY OK
+ --#HWSTATUS_CATEGORY DEVICEBAY
+ --#ACTION "Check the blade server and enclosure SYSLOG."
+
+ ::= 22056
+
+ cpqRackServerBladeMangementControllerFirmwareUpdating TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackServerBladeEnclosureName,
+ cpqRackServerBladeName,
+ cpqRackServerBladePosition,
+ cpqRackServerBladeSparePartNumber,
+ cpqRackCommonEnclosureSerialNum,
+ cpqRackServerBladeSerialNum,
+ cpqRackServerBladeUid,
+ cpqRackServerBladeManagementDeviceFirmwareFlashingStatus,
+ cpqRackCommonEnclosureTrapSequenceNum }
+ DESCRIPTION
+ "Server blade's management controller firmware updating.
+
+ This server blade's management controller has started updating it's firmware.
+
+ User Action: None."
+
+ --#TYPE "Server blade management controller firmware update started (22057)"
+ --#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s has started updating it's management controller firmware."
+ --#ARGUMENTS {5, 6, 4, 2}
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 99
+ --#STATE OPERATIONAL
+ --#SIMPLE_SEVERITY OK
+ --#HWSTATUS_CATEGORY DEVICEBAY
+ --#LIFECYCLE
+
+ ::= 22057
+
+ cpqRackServerBladeMangementControllerFirmwareUpdateComplete TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackServerBladeEnclosureName,
+ cpqRackServerBladeName,
+ cpqRackServerBladePosition,
+ cpqRackServerBladeSparePartNumber,
+ cpqRackCommonEnclosureSerialNum,
+ cpqRackServerBladeSerialNum,
+ cpqRackServerBladeUid,
+ cpqRackServerBladeManagementDeviceFirmwareFlashingStatus,
+ cpqRackCommonEnclosureTrapSequenceNum }
+ DESCRIPTION
+ "Server blade's management controller firmware update has completed.
+
+ This server blade's management controller has finished updating it's firmware.
+
+ User Action: None."
+
+ --#TYPE "Server blade management controller firmware update completed (22058)"
+ --#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s has finished updating it's management controller firmware."
+ --#ARGUMENTS {5, 6, 4, 2}
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 99
+ --#STATE OPERATIONAL
+ --#SIMPLE_SEVERITY OK
+ --#HWSTATUS_CATEGORY DEVICEBAY
+ --#LIFECYCLE
+
+ ::= 22058
+
+ cpqRackServerBladeSystemBIOSFirmwareUpdating TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackServerBladeEnclosureName,
+ cpqRackServerBladeName,
+ cpqRackServerBladePosition,
+ cpqRackServerBladeSparePartNumber,
+ cpqRackCommonEnclosureSerialNum,
+ cpqRackServerBladeSerialNum,
+ cpqRackServerBladeUid,
+ cpqRackServerBladeSystemBIOSFlashingStatus,
+ cpqRackCommonEnclosureTrapSequenceNum }
+ DESCRIPTION
+ "Server blade's system BIOS firmware updating.
+
+ This server blade's system BIOS has started updating.
+
+ User Action: None."
+
+ --#TYPE "Server blade system BIOS firmware update started (22059)"
+ --#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s has started updating it's system BIOS firmware."
+ --#ARGUMENTS {5, 6, 4, 2}
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 99
+ --#STATE OPERATIONAL
+ --#SIMPLE_SEVERITY OK
+ --#HWSTATUS_CATEGORY DEVICEBAY
+ --#LIFECYCLE
+
+ ::= 22059
+
+ cpqRackServerBladeSystemBIOSFirmwareUpdateCompleted TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackServerBladeEnclosureName,
+ cpqRackServerBladeName,
+ cpqRackServerBladePosition,
+ cpqRackServerBladeSparePartNumber,
+ cpqRackCommonEnclosureSerialNum,
+ cpqRackServerBladeSerialNum,
+ cpqRackServerBladeUid,
+ cpqRackServerBladeSystemBIOSFlashingStatus,
+ cpqRackCommonEnclosureTrapSequenceNum }
+ DESCRIPTION
+ "Server blade's system BIOS firmware update complete.
+
+ This server blade's system BIOS has completed updating.
+
+ User Action: None."
+
+ --#TYPE "Server blade system BIOS firmware update completed (22060)"
+ --#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s has completed updating it's system BIOS firmware."
+ --#ARGUMENTS {5, 6, 4, 2}
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 99
+ --#STATE OPERATIONAL
+ --#SIMPLE_SEVERITY OK
+ --#HWSTATUS_CATEGORY DEVICEBAY
+ --#LIFECYCLE
+
+ ::= 22060
+
+
+ cpqRackServerBladeFrontIOBlankingActive TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackServerBladeEnclosureName,
+ cpqRackServerBladeName,
+ cpqRackServerBladePosition,
+ cpqRackServerBladeSparePartNumber,
+ cpqRackCommonEnclosureSerialNum,
+ cpqRackServerBladeSerialNum,
+ cpqRackServerBladeUid,
+ cpqRackServerBladeFrontIOBlankingModeStatus,
+ cpqRackCommonEnclosureTrapSequenceNum }
+ DESCRIPTION
+ "Server blade has disabled front IO ports.
+
+ Front IO blanking status has changed to active for this server blade.
+
+ User Action: None."
+
+ --#TYPE "Server blade front IO blanking active (22061)"
+ --#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s has disabled front IO."
+ --#ARGUMENTS {5, 6, 4, 2}
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 99
+ --#STATE OPERATIONAL
+ --#SIMPLE_SEVERITY OK
+ --#HWSTATUS_CATEGORY DEVICEBAY
+ --#LIFECYCLE
+
+ ::= 22061
+
+
+ cpqRackServerBladeRemoteFrontIOBlankingInactive TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackServerBladeEnclosureName,
+ cpqRackServerBladeName,
+ cpqRackServerBladePosition,
+ cpqRackServerBladeSparePartNumber,
+ cpqRackCommonEnclosureSerialNum,
+ cpqRackServerBladeSerialNum,
+ cpqRackServerBladeUid,
+ cpqRackServerBladeFrontIOBlankingModeStatus,
+ cpqRackCommonEnclosureTrapSequenceNum }
+ DESCRIPTION
+ "Server blade has front IO blanking mode now inactive.
+
+ Front IO blanking status has changed to inactive for this server blade.
+
+ User Action: None."
+
+ --#TYPE "Server blade front IO blanking inactive (22062)"
+ --#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s has enabled front IO."
+ --#ARGUMENTS {5, 6, 4, 2}
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 99
+ --#STATE OPERATIONAL
+ --#SIMPLE_SEVERITY OK
+ --#HWSTATUS_CATEGORY DEVICEBAY
+ --#LIFECYCLE
+
+ ::= 22062
+
+ cpqRackServerBladeDiagnosticAdaptorInserted TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackServerBladeEnclosureName,
+ cpqRackServerBladeName,
+ cpqRackServerBladePosition,
+ cpqRackServerBladeSparePartNumber,
+ cpqRackCommonEnclosureSerialNum,
+ cpqRackServerBladeSerialNum,
+ cpqRackServerBladeUid,
+ cpqRackServerBladeDiagnosticAdaptorPresence,
+ cpqRackCommonEnclosureTrapSequenceNum }
+ DESCRIPTION
+ "Server blade diagnostic adaptor inserted.
+
+ Blade diagnostic adaptor status has changed to inserted for this server blade.
+
+ User Action: None."
+
+ --#TYPE "Server blade diagnostic adaptor inserted (22063)"
+ --#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s diagnostic adaptor inserted."
+ --#ARGUMENTS {5, 6, 4, 2}
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 99
+ --#STATE OPERATIONAL
+ --#SIMPLE_SEVERITY OK
+ --#HWSTATUS_CATEGORY DEVICEBAY
+ --#LIFECYCLE
+
+ ::= 22063
+
+ cpqRackServerBladeDiagnosticAdaptorRemoved TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackServerBladeEnclosureName,
+ cpqRackServerBladeName,
+ cpqRackServerBladePosition,
+ cpqRackServerBladeSparePartNumber,
+ cpqRackCommonEnclosureSerialNum,
+ cpqRackServerBladeSerialNum,
+ cpqRackServerBladeUid,
+ cpqRackServerBladeDiagnosticAdaptorPresence,
+ cpqRackCommonEnclosureTrapSequenceNum }
+ DESCRIPTION
+ "Server blade diagnostic adaptor removed.
+
+ Blade diagnostic adaptor status has changed to removed for this server blade.
+
+ User Action: None."
+
+ --#TYPE "Server blade diagnostic adaptor removed (22064)"
+ --#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s diagnostic adaptor removed."
+ --#ARGUMENTS {5, 6, 4, 2}
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 99
+ --#STATE OPERATIONAL
+ --#SIMPLE_SEVERITY OK
+ --#HWSTATUS_CATEGORY DEVICEBAY
+ --#LIFECYCLE
+
+ ::= 22064
+
+ cpqRackServerBladeEnteredPXEBootMode TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackServerBladeEnclosureName,
+ cpqRackServerBladeName,
+ cpqRackServerBladePosition,
+ cpqRackServerBladeSparePartNumber,
+ cpqRackCommonEnclosureSerialNum,
+ cpqRackServerBladeSerialNum,
+ cpqRackServerBladeUid,
+ cpqRackServerBladePXEBootModeStatus,
+ cpqRackCommonEnclosureTrapSequenceNum }
+ DESCRIPTION
+ "Server blade has entered PXE Boot Mode.
+
+ Server blade Pre-Boot-eXecution (PXE) Mode started.
+
+ User Action: None."
+
+ --#TYPE "Server blade has entered PXE Boot Mode (22065)"
+ --#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s has entered PXE Boot Mode."
+ --#ARGUMENTS {5, 6, 4, 2}
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 99
+ --#STATE OPERATIONAL
+ --#SIMPLE_SEVERITY OK
+ --#HWSTATUS_CATEGORY DEVICEBAY
+ --#LIFECYCLE
+
+ ::= 22065
+
+ cpqRackServerBladeExitedPXEBootMode TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackServerBladeEnclosureName,
+ cpqRackServerBladeName,
+ cpqRackServerBladePosition,
+ cpqRackServerBladeSparePartNumber,
+ cpqRackCommonEnclosureSerialNum,
+ cpqRackServerBladeSerialNum,
+ cpqRackServerBladeUid,
+ cpqRackServerBladePXEBootModeStatus,
+ cpqRackCommonEnclosureTrapSequenceNum }
+ DESCRIPTION
+ "Server blade has exited PXE Boot Mode.
+
+ Server blade Pre-Boot-eXecution (PXE) Mode exited.
+
+ User Action: None."
+
+ --#TYPE "Server blade has exited PXE Boot Mode (22066)"
+ --#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s has exited PXE Boot Mode."
+ --#ARGUMENTS {5, 6, 4, 2}
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 99
+ --#STATE OPERATIONAL
+ --#SIMPLE_SEVERITY OK
+ --#HWSTATUS_CATEGORY DEVICEBAY
+ --#LIFECYCLE
+
+ ::= 22066
+
+
+ cpqRackServerBladeWarmReset TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackServerBladeEnclosureName,
+ cpqRackServerBladeName,
+ cpqRackServerBladePosition,
+ cpqRackServerBladeSparePartNumber,
+ cpqRackCommonEnclosureSerialNum,
+ cpqRackServerBladeSerialNum,
+ cpqRackServerBladeUid,
+ cpqRackServerBladePOSTStatus,
+ cpqRackCommonEnclosureTrapSequenceNum }
+ DESCRIPTION
+ "Server blade has been warm reset.
+
+ Server blade has experienced a warm reset.
+
+ User Action: None."
+
+ --#TYPE "Server blade warm reset occurred (22067)"
+ --#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s has been warm reset."
+ --#ARGUMENTS {5, 6, 4, 2}
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 99
+ --#STATE OPERATIONAL
+ --#SIMPLE_SEVERITY OK
+ --#HWSTATUS_CATEGORY DEVICEBAY
+ --#LIFECYCLE
+
+ ::= 22067
+
+ cpqRackServerBladePOSTCompleted TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackServerBladeEnclosureName,
+ cpqRackServerBladeName,
+ cpqRackServerBladePosition,
+ cpqRackServerBladeSparePartNumber,
+ cpqRackCommonEnclosureSerialNum,
+ cpqRackServerBladeSerialNum,
+ cpqRackServerBladeUid,
+ cpqRackServerBladePOSTStatus,
+ cpqRackCommonEnclosureTrapSequenceNum }
+ DESCRIPTION
+ "Server blade system BIOS POST complete.
+
+ Server blade has completed system BIOS Power-On-Self-Test (POST).
+
+ User Action: None."
+
+ --#TYPE "Server blade system BIOS POST completed (22068)"
+ --#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s system BIOS POST completed."
+ --#ARGUMENTS {5, 6, 4, 2}
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 99
+ --#STATE OPERATIONAL
+ --#SIMPLE_SEVERITY OK
+ --#HWSTATUS_CATEGORY DEVICEBAY
+ --#LIFECYCLE
+
+ ::= 22068
+
+ cpqRackServerBladePoweredOn TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackServerBladeEnclosureName,
+ cpqRackServerBladeName,
+ cpqRackServerBladePosition,
+ cpqRackServerBladeSparePartNumber,
+ cpqRackCommonEnclosureSerialNum,
+ cpqRackServerBladeSerialNum,
+ cpqRackServerBladeUid,
+ cpqRackServerBladePowered,
+ cpqRackCommonEnclosureTrapSequenceNum }
+ DESCRIPTION
+ "Server blade has powered on.
+
+ User Action: None."
+
+ --#TYPE "Server blade has powered on (22069)"
+ --#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s has powered on."
+ --#ARGUMENTS {5, 6, 4, 2}
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 99
+ --#STATE OPERATIONAL
+ --#SIMPLE_SEVERITY OK
+ --#HWSTATUS_CATEGORY DEVICEBAY
+ --#LIFECYCLE
+
+ ::= 22069
+
+ cpqRackServerBladePoweredOff TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackServerBladeEnclosureName,
+ cpqRackServerBladeName,
+ cpqRackServerBladePosition,
+ cpqRackServerBladeSparePartNumber,
+ cpqRackCommonEnclosureSerialNum,
+ cpqRackServerBladeSerialNum,
+ cpqRackServerBladeUid,
+ cpqRackServerBladePowered,
+ cpqRackCommonEnclosureTrapSequenceNum }
+ DESCRIPTION
+ "Server blade has powered off.
+
+ User Action: None."
+
+ --#TYPE "Server blade has powered off (22070)"
+ --#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s has powered off."
+ --#ARGUMENTS {5, 6, 4, 2}
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 99
+ --#STATE OPERATIONAL
+ --#SIMPLE_SEVERITY OK
+ --#HWSTATUS_CATEGORY DEVICEBAY
+ --#LIFECYCLE
+
+ ::= 22070
+
+ cpqRackInformationalEAETrap TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackServerBladeEnclosureName,
+ cpqRackCommonEnclosureTrapSequenceNum,
+ cpqRackLastEAEEvent }
+
+ DESCRIPTION
+ "EAE Informational trap"
+
+ --#TYPE "Generic EAE Informational trap"
+ --#SUMMARY "%s"
+ --#ARGUMENTS {6}
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 99
+ --#SIMPLE_SEVERITY OK
+ --#HWSTATUS_CATEGORY NONE
+
+ ::= 22071
+
+ cpqRackMinorEAETrap TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackServerBladeEnclosureName,
+ cpqRackCommonEnclosureTrapSequenceNum,
+ cpqRackLastEAEEvent }
+
+ DESCRIPTION
+ "EAE Minor trap"
+
+ --#TYPE "Generic EAE Minor trap"
+ --#SUMMARY "%s"
+ --#ARGUMENTS {6}
+ --#SEVERITY MINOR
+ --#TIMEINDEX 99
+ --#SIMPLE_SEVERITY MAJOR
+ --#HWSTATUS_CATEGORY NONE
+ ::= 22072
+
+ cpqRackMajorEAETrap TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackServerBladeEnclosureName,
+ cpqRackCommonEnclosureTrapSequenceNum,
+ cpqRackLastEAEEvent }
+
+ DESCRIPTION
+ "EAE Major trap"
+
+ --#TYPE "Generic EAE Major trap"
+ --#SUMMARY "%s"
+ --#ARGUMENTS {6}
+ --#SEVERITY MAJOR
+ --#TIMEINDEX 99
+ --#SIMPLE_SEVERITY MAJOR
+ --#HWSTATUS_CATEGORY NONE
+ ::= 22073
+
+ cpqRackCriticalEAETrap TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackServerBladeEnclosureName,
+ cpqRackCommonEnclosureTrapSequenceNum,
+ cpqRackLastEAEEvent }
+
+ DESCRIPTION
+ "EAE Critical trap"
+
+ --#TYPE "Generic EAE Critical trap"
+ --#SUMMARY "%s"
+ --#ARGUMENTS {6}
+ --#SEVERITY CRITICAL
+ --#TIMEINDEX 99
+ --#SIMPLE_SEVERITY CRITICAL
+ --#HWSTATUS_CATEGORY NONE
+ ::= 22074
+
+ cpqRackPowerMinorEAETrap TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackServerBladeEnclosureName,
+ cpqRackCommonEnclosureTrapSequenceNum,
+ cpqRackLastEAEEvent }
+
+ DESCRIPTION
+ "FlexFabric Cmdr Power Subsystem Minor trap.
+ User Action: For FlexFabric Cmdr, please refer to product documentation for
+ possible corrective actions."
+
+ --#TYPE "Generic Power Subsystem EAE Minor trap"
+ --#SUMMARY "%s"
+ --#ARGUMENTS {6}
+ --#SEVERITY MINOR
+ --#TIMEINDEX 99
+ --#SIMPLE_SEVERITY MAJOR
+ --#HWSTATUS_CATEGORY NONE
+ ::= 22075
+
+
+ cpqRackPowerMajorEAETrap TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackServerBladeEnclosureName,
+ cpqRackCommonEnclosureTrapSequenceNum,
+ cpqRackLastEAEEvent }
+
+ DESCRIPTION
+ "FlexFabric Cmdr Power Subsystem Major trap.
+ User Action: For FlexFabric Cmdr, please refer to product documentation for
+ possible corrective actions."
+
+ --#TYPE "Generic Power Subsystem EAE Major trap"
+ --#SUMMARY "%s"
+ --#ARGUMENTS {6}
+ --#SEVERITY MAJOR
+ --#TIMEINDEX 99
+ --#SIMPLE_SEVERITY MAJOR
+ --#HWSTATUS_CATEGORY NONE
+ ::= 22076
+
+ cpqRackPowerCriticalEAETrap TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackServerBladeEnclosureName,
+ cpqRackCommonEnclosureTrapSequenceNum,
+ cpqRackLastEAEEvent }
+
+ DESCRIPTION
+ "FlexFabric Cmdr Power Subsystem Critical trap.
+ User Action: For FlexFabric Cmdr, please refer to product documentation for
+ possible corrective actions."
+
+ --#TYPE "Generic Power Subsystem EAE Critical trap"
+ --#SUMMARY "%s"
+ --#ARGUMENTS {6}
+ --#SEVERITY CRITICAL
+ --#TIMEINDEX 99
+ --#SIMPLE_SEVERITY CRITICAL
+ --#HWSTATUS_CATEGORY NONE
+ ::= 22077
+
+ cpqRackServerBladePartitionChange TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackServerBladeEnclosureName,
+ cpqRackServerBladeName,
+ cpqRackServerBladePosition,
+ cpqRackServerBladeSparePartNumber,
+ cpqRackCommonEnclosureSerialNum,
+ cpqRackServerBladeSerialNum,
+ cpqRackServerBladeUid,
+ cpqRackCommonEnclosureTrapSequenceNum }
+ DESCRIPTION
+ "Server Blade Partition Changed trap.
+
+ The server blade is part of a conjoined blade and its partition has changed.
+
+ User Action: None."
+
+ --#TYPE "Server blade partition changed (22078)"
+ --#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s partition has changed."
+ --#ARGUMENTS {5, 6, 4, 2}
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 99
+ --#STATE OPERATIONAL
+ --#SIMPLE_SEVERITY OK
+ --#HWSTATUS_CATEGORY DEVICEBAY
+ --#LIFECYCLE
+
+ ::= 22078
+
+ cpqRackInformationalWSMANTrap TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackCommonEnclosureName,
+ cpqRackCommonEnclosureTrapSequenceNum,
+ cpqRackLastEAEEvent,
+ cpqRackEventIndicationIdentifier,
+ cpqRackEventIndicationTime,
+ cpqRackEventDescription,
+ cpqRackEventSummary,
+ cpqRackEventCategory,
+ cpqRackOtherEventCategory,
+ cpqRackEventSubCategory,
+ cpqRackOtherEventSubCategory,
+ cpqRackEventThreshold,
+ cpqRackEventTimeWin,
+ cpqRackEventActualThreshold,
+ cpqRackEventActualTimeWin,
+ cpqRackEventProviderVersion,
+ cpqHoOsType,
+ cpqHoVersion,
+ cpqRackNetworkAddresses,
+ cpqRackSerialNum,
+ cpqRackEventAlertingElementFormat,
+ cpqRackEventOtherAlertingElementFormat,
+ cpqRackEventImpactedDomain,
+ cpqRackEventComplexName,
+ cpqRackEventPartitionId,
+ cpqRackEventTriggeringLogID,
+ cpqRackEventTriggeringLogIDFormat,
+ cpqRackHWPartNumber,
+ cpqRackHWFirmwareVersion,
+ cpqRackHWManufacturer,
+ cpqRackHWSerialNumber,
+ cpqRackHWFRUDetails,
+ cpqRackHWDevicePermanentNameFormat,
+ cpqRackHWOtherPermanentNameFormat,
+ cpqRackEventAlertType,
+ cpqRackEventOtherAlertType,
+ cpqRackEventProbableCause,
+ cpqRackEventProbableCauseDescription,
+ cpqRackEventPerceivedSeverity,
+ cpqRackEventOtherSeverity,
+ cpqRackEventTrending,
+ cpqRackEventRecommendedActions,
+ cpqRackEventID,
+ cpqRackEventTime,
+ cpqRackEventSystemCreationClassName,
+ cpqRackEventSystemName,
+ cpqRackEventProviderName }
+
+ DESCRIPTION
+ "WSMAN Informational trap"
+
+ --#TYPE "Generic WSMAN Informational trap"
+ --#SUMMARY "%s"
+ --#ARGUMENTS {6}
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 99
+ --#SIMPLE_SEVERITY OK
+ --#HWSTATUS_CATEGORY NONE
+
+ ::= 22079
+
+ cpqRackMinorWSMANTrap TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackCommonEnclosureName,
+ cpqRackCommonEnclosureTrapSequenceNum,
+ cpqRackLastEAEEvent,
+ cpqRackEventIndicationIdentifier,
+ cpqRackEventIndicationTime,
+ cpqRackEventDescription,
+ cpqRackEventSummary,
+ cpqRackEventCategory,
+ cpqRackOtherEventCategory,
+ cpqRackEventSubCategory,
+ cpqRackOtherEventSubCategory,
+ cpqRackEventThreshold,
+ cpqRackEventTimeWin,
+ cpqRackEventActualThreshold,
+ cpqRackEventActualTimeWin,
+ cpqRackEventProviderVersion,
+ cpqHoOsType,
+ cpqHoVersion,
+ cpqRackNetworkAddresses,
+ cpqRackSerialNum,
+ cpqRackEventAlertingElementFormat,
+ cpqRackEventOtherAlertingElementFormat,
+ cpqRackEventImpactedDomain,
+ cpqRackEventComplexName,
+ cpqRackEventPartitionId,
+ cpqRackEventTriggeringLogID,
+ cpqRackEventTriggeringLogIDFormat,
+ cpqRackHWPartNumber,
+ cpqRackHWFirmwareVersion,
+ cpqRackHWManufacturer,
+ cpqRackHWSerialNumber,
+ cpqRackHWFRUDetails,
+ cpqRackHWDevicePermanentNameFormat,
+ cpqRackHWOtherPermanentNameFormat,
+ cpqRackEventAlertType,
+ cpqRackEventOtherAlertType,
+ cpqRackEventProbableCause,
+ cpqRackEventProbableCauseDescription,
+ cpqRackEventPerceivedSeverity,
+ cpqRackEventOtherSeverity,
+ cpqRackEventTrending,
+ cpqRackEventRecommendedActions,
+ cpqRackEventID,
+ cpqRackEventTime,
+ cpqRackEventSystemCreationClassName,
+ cpqRackEventSystemName,
+ cpqRackEventProviderName }
+
+ DESCRIPTION
+ "WSMAN Minor trap"
+
+ --#TYPE "Generic WSMAN Minor trap"
+ --#SUMMARY "%s"
+ --#ARGUMENTS {6}
+ --#SEVERITY MINOR
+ --#TIMEINDEX 99
+ --#SIMPLE_SEVERITY MAJOR
+ --#HWSTATUS_CATEGORY NONE
+ ::= 22080
+
+ cpqRackMajorWSMANTrap TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackCommonEnclosureName,
+ cpqRackCommonEnclosureTrapSequenceNum,
+ cpqRackLastEAEEvent,
+ cpqRackEventIndicationIdentifier,
+ cpqRackEventIndicationTime,
+ cpqRackEventDescription,
+ cpqRackEventSummary,
+ cpqRackEventCategory,
+ cpqRackOtherEventCategory,
+ cpqRackEventSubCategory,
+ cpqRackOtherEventSubCategory,
+ cpqRackEventThreshold,
+ cpqRackEventTimeWin,
+ cpqRackEventActualThreshold,
+ cpqRackEventActualTimeWin,
+ cpqRackEventProviderVersion,
+ cpqHoOsType,
+ cpqHoVersion,
+ cpqRackNetworkAddresses,
+ cpqRackSerialNum,
+ cpqRackEventAlertingElementFormat,
+ cpqRackEventOtherAlertingElementFormat,
+ cpqRackEventImpactedDomain,
+ cpqRackEventComplexName,
+ cpqRackEventPartitionId,
+ cpqRackEventTriggeringLogID,
+ cpqRackEventTriggeringLogIDFormat,
+ cpqRackHWPartNumber,
+ cpqRackHWFirmwareVersion,
+ cpqRackHWManufacturer,
+ cpqRackHWSerialNumber,
+ cpqRackHWFRUDetails,
+ cpqRackHWDevicePermanentNameFormat,
+ cpqRackHWOtherPermanentNameFormat,
+ cpqRackEventAlertType,
+ cpqRackEventOtherAlertType,
+ cpqRackEventProbableCause,
+ cpqRackEventProbableCauseDescription,
+ cpqRackEventPerceivedSeverity,
+ cpqRackEventOtherSeverity,
+ cpqRackEventTrending,
+ cpqRackEventRecommendedActions,
+ cpqRackEventID,
+ cpqRackEventTime,
+ cpqRackEventSystemCreationClassName,
+ cpqRackEventSystemName,
+ cpqRackEventProviderName }
+
+ DESCRIPTION
+ "WSMAN Major trap"
+
+ --#TYPE "Generic WSMAN Major trap"
+ --#SUMMARY "%s"
+ --#ARGUMENTS {6}
+ --#SEVERITY MAJOR
+ --#TIMEINDEX 99
+ --#SIMPLE_SEVERITY MAJOR
+ --#HWSTATUS_CATEGORY NONE
+ ::= 22081
+
+ cpqRackCriticalWSMANTrap TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackCommonEnclosureName,
+ cpqRackCommonEnclosureTrapSequenceNum,
+ cpqRackLastEAEEvent,
+ cpqRackEventIndicationIdentifier,
+ cpqRackEventIndicationTime,
+ cpqRackEventDescription,
+ cpqRackEventSummary,
+ cpqRackEventCategory,
+ cpqRackOtherEventCategory,
+ cpqRackEventSubCategory,
+ cpqRackOtherEventSubCategory,
+ cpqRackEventThreshold,
+ cpqRackEventTimeWin,
+ cpqRackEventActualThreshold,
+ cpqRackEventActualTimeWin,
+ cpqRackEventProviderVersion,
+ cpqHoOsType,
+ cpqHoVersion,
+ cpqRackNetworkAddresses,
+ cpqRackSerialNum,
+ cpqRackEventAlertingElementFormat,
+ cpqRackEventOtherAlertingElementFormat,
+ cpqRackEventImpactedDomain,
+ cpqRackEventComplexName,
+ cpqRackEventPartitionId,
+ cpqRackEventTriggeringLogID,
+ cpqRackEventTriggeringLogIDFormat,
+ cpqRackHWPartNumber,
+ cpqRackHWFirmwareVersion,
+ cpqRackHWManufacturer,
+ cpqRackHWSerialNumber,
+ cpqRackHWFRUDetails,
+ cpqRackHWDevicePermanentNameFormat,
+ cpqRackHWOtherPermanentNameFormat,
+ cpqRackEventAlertType,
+ cpqRackEventOtherAlertType,
+ cpqRackEventProbableCause,
+ cpqRackEventProbableCauseDescription,
+ cpqRackEventPerceivedSeverity,
+ cpqRackEventOtherSeverity,
+ cpqRackEventTrending,
+ cpqRackEventRecommendedActions,
+ cpqRackEventID,
+ cpqRackEventTime,
+ cpqRackEventSystemCreationClassName,
+ cpqRackEventSystemName,
+ cpqRackEventProviderName }
+
+ DESCRIPTION
+ "WSMAN Critical trap"
+
+ --#TYPE "Generic WSMAN Critical trap"
+ --#SUMMARY "%s"
+ --#ARGUMENTS {6}
+ --#SEVERITY CRITICAL
+ --#TIMEINDEX 99
+ --#SIMPLE_SEVERITY CRITICAL
+ --#HWSTATUS_CATEGORY NONE
+ ::= 22082
+
+ cpqRackEnclosureManagerLinkDown TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackCommonEnclosureName,
+ cpqRackCommonEnclosureSerialNum,
+ cpqRackCommonEnclosureManagerLocation,
+ cpqRackCommonEnclosureManagerSparePartNumber,
+ cpqRackCommonEnclosureManagerSerialNum,
+ cpqRackCommonEnclosureTrapSequenceNum }
+ DESCRIPTION
+ "The Onboard Administrator Network Link is Down.
+
+ The Onboard Administrator firmware has detected the loss of network link.
+ User Action: Check network connection and configurations for the Onboard Administrator."
+
+ --#TYPE "Onboard Administrator Link Down (22083)"
+ --#SUMMARY "Onboard Administrator Link Down."
+ --#ARGUMENTS { }
+ --#SEVERITY CRITICAL
+ --#TIMEINDEX 99
+ --#STATE DEGRADED
+ --#SIMPLE_SEVERITY CRITICAL
+ --#HWSTATUS_CATEGORY NETWORK
+ --#ACTION "Check network connection and configurations for the Onboard Administrator."
+
+ ::= 22083
+
+ cpqRackEnclosureManagerLinkUp TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackCommonEnclosureName,
+ cpqRackCommonEnclosureSerialNum,
+ cpqRackCommonEnclosureManagerLocation,
+ cpqRackCommonEnclosureManagerSparePartNumber,
+ cpqRackCommonEnclosureManagerSerialNum,
+ cpqRackCommonEnclosureTrapSequenceNum }
+ DESCRIPTION
+ "The Onboard Administrator Network Link is Up.
+
+ The Onboard Administrator firmware has detected the presence of network link.
+ User Action: None."
+
+ --#TYPE "Onboard Administrator Link Up (22084)"
+ --#SUMMARY "Onboard Administrator Link Up."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 99
+ --#STATE OPERATIONAL
+ --#SIMPLE_SEVERITY OK
+ --#HWSTATUS_CATEGORY NETWORKK
+
+ ::= 22084
+
+ cpqRackErsCommFailure TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackCommonEnclosureName,
+ cpqRackCommonEnclosureSerialNum,
+ cpqRackCommonEnclosureSparePartNumber,
+ cpqRackErsTransactionType,
+ cpqRackErsConnectionModel,
+ cpqRackErsFailureCode,
+ cpqRackErsRemoteHost }
+
+ DESCRIPTION
+ "The Onboard Administrator to Insight Remote Support or Insight Online communication failed.
+ User Action: Please check the connectivity to Insight Remote Support or Insight Online."
+
+ --#TYPE "Onboard Administrator to Insight Remote Support or Insight Online communication failure (22085)"
+ --#SUMMARY "Onboard Administrator in enclosure %s, in rack %s to Insight Remote Support or Insight Online communication failed."
+ --#ARGUMENTS {4, 2}
+ --#SEVERITY MAJOR
+ --#TIMEINDEX 99
+ --#STATE DEGRADED
+ --#SIMPLE_SEVERITY MAJOR
+ --#HWSTATUS_CATEGORY REMOTESUPPORT
+ --#ACTION "Please check the connectivity to Insight Remote Support or Insight Online."
+
+ ::= 22085
+
+ cpqRackPowerSubsystemOverloadConditionRepaired TRAP-TYPE
+ ENTERPRISE compaq
+ VARIABLES { sysName,
+ cpqHoTrapFlags,
+ cpqRackName,
+ cpqRackUid,
+ cpqRackPowerEnclosureName,
+ cpqRackCommonEnclosureSparePartNumber,
+ cpqRackCommonEnclosureSerialNum,
+ cpqRackCommonEnclosureTrapSequenceNum }
+ DESCRIPTION
+ "The rack power subsystem overload condition repaired."
+
+ --#TYPE "Rack power subsystem overload condition repaired (22086)"
+ --#SUMMARY "The power subsystem overload condition in enclosure %s in rack %s is repaired."
+ --#ARGUMENTS {4, 2}
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 99
+ --#STATE OPERATIONAL
+ --#SIMPLE_SEVERITY OK
+ --#HWSTATUS_CATEGORY POWER
+
+ ::= 22086
+
+END
+
|