summaryrefslogtreecommitdiff
path: root/MIBS/ingrasys/IPOMANII-MIB
diff options
context:
space:
mode:
authorDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
committerDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
commit98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch)
tree9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/ingrasys/IPOMANII-MIB
downloadmibs-main.tar.gz
mibs-main.zip
Initial commitHEADmain
Diffstat (limited to 'MIBS/ingrasys/IPOMANII-MIB')
-rw-r--r--MIBS/ingrasys/IPOMANII-MIB4570
1 files changed, 4570 insertions, 0 deletions
diff --git a/MIBS/ingrasys/IPOMANII-MIB b/MIBS/ingrasys/IPOMANII-MIB
new file mode 100644
index 0000000..28c6651
--- /dev/null
+++ b/MIBS/ingrasys/IPOMANII-MIB
@@ -0,0 +1,4570 @@
+-- Ingrasys iPoManII MIB
+-- MIB for Intelligent Power Management
+--
+-- { iso org(3) dod(6) internet(1) private(4) enterprises(1) ingrasys(2468)
+-- product(1) pduAgent(4) iPoManII(1)
+-- ==============================================================================================
+---
+--- Revision History
+---
+--- v0.80 20-Apr-2005 Ming Lu/Ingrasys
+--- Created
+---
+--- v0.81 04-Aug-2007 Ming Lu/Ingrasys
+--- Modify Some error from Web check issue
+--- Add Slave mib data and control
+---
+--- v0.82 04-Oct-2007 Ming Lu/Ingrasys
+--- Modify Some error from Web check issue
+---
+--- v1.00 06-Dec-2007 Ming Lu/Ingrasys
+--- Add Slave trap 26-150
+---
+--- v1.01 25-Jan-2008 Ming Lu/Ingrasys
+--- Modify Some mib wording error
+---
+--- v1.02 30-Jan-2008 Ming Lu/Ingrasys
+--- Modify Some mib wording error
+---
+--- v1.03 09-Apr-2010 Ming Lu/Ingrasys
+--- Add reset WattItem
+---
+IPOMANII-MIB DEFINITIONS ::= BEGIN
+
+IMPORTS
+ enterprises
+ FROM RFC1155-SMI
+ OBJECT-TYPE
+ FROM RFC-1212
+ DisplayString
+ FROM RFC1213-MIB
+ TRAP-TYPE
+ FROM RFC-1215;
+
+ingrasys OBJECT IDENTIFIER ::= { enterprises 2468 }
+product OBJECT IDENTIFIER ::= { ingrasys 1 }
+pduAgent OBJECT IDENTIFIER ::= { product 4 }
+iPoManII OBJECT IDENTIFIER ::= { pduAgent 2 }
+ipmObjects OBJECT IDENTIFIER ::= { iPoManII 1 }
+ipmTraps OBJECT IDENTIFIER ::= { iPoManII 2 }
+
+ipmIdent OBJECT IDENTIFIER ::= { ipmObjects 1 }
+ipmAgent OBJECT IDENTIFIER ::= { ipmObjects 2 }
+ipmDevice OBJECT IDENTIFIER ::= { ipmObjects 3 }
+ipmSlave OBJECT IDENTIFIER ::= { ipmObjects 4 }
+ipmEnv OBJECT IDENTIFIER ::= { ipmObjects 5 }
+
+-- ===========================================================================
+--
+-- ipmIdent
+--
+-- iPoManII Identification Group
+--
+-- ===========================================================================
+ipmIdentManufacturer OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..31))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The name of manufacturer."
+ ::= { ipmIdent 1 }
+
+ipmIdentModel OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..31))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The Model designation of device."
+ ::= { ipmIdent 2 }
+
+ipmIdentAgentSoftwareVersion OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..63))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The firmware version of the device."
+ ::= { ipmIdent 3 }
+
+ipmIdentName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..31))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A description of this device."
+ ::= { ipmIdent 4 }
+
+ipmAgentConfig OBJECT IDENTIFIER ::= { ipmAgent 1 }
+-- ===========================================================================
+--
+-- ipmConfig
+--
+-- iPoManII Configuration Group, configure the secific features of iPoManII
+--
+-- ===========================================================================
+ipmAgentMibVersion OBJECT-TYPE
+ SYNTAX INTEGER (1..65500) --
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The Mib Version implemented on this device."
+ ::= { ipmAgentConfig 1 }
+
+ipmAgentTime OBJECT IDENTIFIER ::= { ipmAgent 2 }
+-- ===========================================================================
+--
+-- ipmConfigTime
+--
+-- Date/Time Configuration Group of the device.
+--
+-- ===========================================================================
+ipmAgentTimeDate OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (10..10))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The date in agent, format is (dd/mm/yyyy)"
+ ::= { ipmAgentTime 1 }
+
+ipmAgentTimeTime OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (8..8))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The time in agent, format is (hh:mm:ss)"
+ ::= { ipmAgentTime 2 }
+
+ipmAgentTimerFromNtp OBJECT-TYPE
+ SYNTAX INTEGER {
+ enabled(1),
+ disabled(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Enable or disable the agent to synchronize date/time with NTP server."
+ ::= { ipmAgentTime 3 }
+
+ipmAgentNtpIpAddress OBJECT-TYPE
+ SYNTAX IpAddress
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The ip address of NTP server."
+ ::= { ipmAgentTime 4 }
+
+ipmAgentNtpTimeZone OBJECT-TYPE
+ SYNTAX INTEGER {
+ gMT-1200(1),
+ gMT-1100(2),
+ gMT-1000(3),
+ gMT-0900(4),
+ gMT-0800(5),
+ gMT-0700(6),
+ gMT-0600(7),
+ gMT-0500(8),
+ gMT-0400(9),
+ gMT-0330(10),
+ gMT-0300(11),
+ gMT-0200(12),
+ gMT-0100(13),
+ gMT-0000(14),
+ gMT0100(15),
+ gMT0200(16),
+ gMT0300(17),
+ gMT0330(18),
+ gMT0400(19),
+ gMT0500(20),
+ gMT0530(21),
+ gMT0600(22),
+ gMT0700(23),
+ gMT0800(24),
+ gMT0900(25),
+ gMT1000(26),
+ gMT1100(27),
+ gMT1200(28)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Time Zone to use when synchronize with NTP server."
+ ::= { ipmAgentTime 5 }
+
+ipmAgentDayLightSaving OBJECT-TYPE
+ SYNTAX INTEGER {
+ enabled(1),
+ disabled(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Enable/disable the Day Light Saving when synchronize with NTP server."
+ ::= { ipmAgentTime 6 }
+
+ipmAgentNetwork OBJECT IDENTIFIER ::= { ipmAgent 3 }
+-- ===========================================================================
+--
+-- ipmConfigNetwork
+--
+-- Network Configuration Group of the device.
+--
+-- ===========================================================================
+
+ipmAgentNetworkIp OBJECT IDENTIFIER ::= { ipmAgentNetwork 1 }
+-- ===========================================================================
+--
+-- ipmAgentNetworkIp
+--
+-- Ip address Configuration Group of the device.
+--
+-- ===========================================================================
+ipmAgentNetworkIpAdress OBJECT-TYPE
+ SYNTAX IpAddress
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The ip address that NMS can identify the managed device."
+ ::= { ipmAgentNetworkIp 1}
+
+ipmAgentNetworkIpGateway OBJECT-TYPE
+ SYNTAX IpAddress
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The default gateway that allow device managed through routers."
+ ::= { ipmAgentNetworkIp 2}
+
+ipmAgentNetworkIpSubnet OBJECT-TYPE
+ SYNTAX IpAddress
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Internet address subnet mask"
+ ::= { ipmAgentNetworkIp 3}
+
+ipmAgentNetworkDhcpControl OBJECT-TYPE
+ SYNTAX INTEGER {
+ enabled(1),
+ disabled(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Enable/disable DHCP protocol"
+ ::= { ipmAgentNetwork 2 }
+
+ipmAgentNetworkPingControl OBJECT-TYPE
+ SYNTAX INTEGER {
+ enabled(1),
+ disabled(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Enable/disable to response to PING request."
+ ::= { ipmAgentNetwork 3 }
+
+ipmAgentNetworkTftpControl OBJECT-TYPE
+ SYNTAX INTEGER {
+ enabled(1),
+ disabled(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Enable/disable TFTP protocol"
+ ::= { ipmAgentNetwork 4 }
+
+ipmAgentNetworkTelnet OBJECT IDENTIFIER ::= { ipmAgentNetwork 5 }
+-- ===========================================================================
+--
+-- ipmConfigNetworkTelnet
+--
+-- Telnet Configuration Group of the device.
+--
+-- ===========================================================================
+ipmAgentTelnetControl OBJECT-TYPE
+ SYNTAX INTEGER {
+ enabled(1),
+ disabled(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Enable/disable Telnet protocol."
+ ::= { ipmAgentNetworkTelnet 1 }
+
+ipmAgentTelnetPort OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The TCP port for telnet"
+ ::= { ipmAgentNetworkTelnet 2}
+
+ipmAgentNetworkHttp OBJECT IDENTIFIER ::= { ipmAgentNetwork 6 }
+-- ===========================================================================
+--
+-- ipmConfigNetworkHttp
+--
+-- HTTP Configuration Group of the device.
+--
+-- ===========================================================================
+ipmAgentHttpControl OBJECT-TYPE
+ SYNTAX INTEGER {
+ enabled(1),
+ disabled(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Enable/disable HTTP protocol."
+ ::= { ipmAgentNetworkHttp 1 }
+
+ipmAgentHttpPort OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The TCP port for HTTP."
+ ::= { ipmAgentNetworkHttp 2}
+
+ipmAgentNetworkSnmp OBJECT IDENTIFIER ::= { ipmAgentNetwork 7 }
+-- ===========================================================================
+--
+-- ipmAgentNetworkSnmp
+--
+-- SNMP Configuration Group of the device.
+--
+-- ===========================================================================
+ipmAgentSnmpControl OBJECT-TYPE
+ SYNTAX INTEGER {
+ enabled(1),
+ disabled(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Enable/disable SNMP protocol."
+ ::= { ipmAgentNetworkSnmp 1 }
+
+ipmAgentSnmpPort OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The UDP port for SNMP."
+ ::= { ipmAgentNetworkSnmp 2}
+
+ipmAgentLog OBJECT IDENTIFIER ::= { ipmAgentConfig 4 }
+-- ===========================================================================
+--
+-- ipmConfigLog
+--
+-- Log Configuration Group of the device.
+--
+-- ===========================================================================
+pduAgentDataLogInterval OBJECT-TYPE
+ SYNTAX INTEGER (60..28800) -- in seconds
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The interval of the updation of the data log. The value
+ is in seconds"
+ ::= { ipmAgentLog 1 }
+
+ipmAgentControl OBJECT IDENTIFIER ::= { ipmAgentConfig 5 }
+-- ===========================================================================
+--
+-- ipmAgentAgentControl
+--
+-- Agent Control Configuration Group of the device.
+--
+-- ===========================================================================
+ipmAgentControlDefault OBJECT-TYPE
+ SYNTAX INTEGER {
+ reset(1),
+ nothing(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Reset all parameters of the agent to default value."
+ ::= { ipmAgentControl 1}
+
+ipmAgentControlRestart OBJECT-TYPE
+ SYNTAX INTEGER {
+ restart(1),
+ nothing(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Restart the agent."
+ ::= { ipmAgentControl 2}
+
+ipmAgentTrap OBJECT IDENTIFIER ::= { ipmAgentConfig 6 }
+-- ===========================================================================
+--
+-- ipmAgentTrap
+--
+-- Trap Configuration Group of the agent.
+--
+-- ===========================================================================
+ipmAgentTrapRetryCount OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The count of repeat traps send to NMS before trap
+ acknowledgement received."
+ ::= { ipmAgentTrap 1}
+
+ipmAgentTrapRetryTime OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The time interval in seconds between retry traps sned to NMS."
+ ::= { ipmAgentTrap 2}
+
+ipmAgentTrapAckSignature OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The signature of trap acknowledgement."
+ ::= { ipmAgentTrap 3}
+
+
+-- ===========================================================================
+--
+-- ipmAgentTrapsReceiversTable
+--
+-- ===========================================================================
+
+ipmAgentTrapsReceiversTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IpmAgentTrapsReceiversEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of managers to send traps to. The number of
+ entries is given by the value of agentConfigNumTrapReceivers"
+ ::= { ipmAgentConfig 7}
+
+ipmAgentTrapsReceiversEntry OBJECT-TYPE
+ SYNTAX IpmAgentTrapsReceiversEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The managers to send traps to."
+ INDEX { trapsIndex }
+ ::= { ipmAgentTrapsReceiversTable 1 }
+
+IpmAgentTrapsReceiversEntry ::=
+ SEQUENCE {
+ trapsIndex INTEGER,
+ trapsReceiverAddr IpAddress,
+ receiverCommunityString DisplayString,
+ receiverNmsType INTEGER,
+ receiverSeverityLevel INTEGER,
+ receiverDescription DisplayString
+ }
+
+trapsIndex OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to a trap receiver entry."
+ ::= { ipmAgentTrapsReceiversEntry 1 }
+
+trapsReceiverAddr OBJECT-TYPE
+ SYNTAX IpAddress
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The IP address of the manager to send a trap to."
+ ::= { ipmAgentTrapsReceiversEntry 2 }
+
+receiverCommunityString OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..15))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The community name to use in the trap when
+ sent to the manager."
+ ::= { ipmAgentTrapsReceiversEntry 3 }
+
+receiverNmsType OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(1),
+ iPoManII-trap(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The trap group that NMS desired."
+ ::= { ipmAgentTrapsReceiversEntry 4 }
+
+receiverSeverityLevel OBJECT-TYPE
+ SYNTAX INTEGER {
+ informational(1),
+ warning(2),
+ severe(3)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The severity level of traps to be received by this manager."
+ ::= { ipmAgentTrapsReceiversEntry 5 }
+
+receiverDescription OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..31))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Description of trap receivers"
+ ::= { ipmAgentTrapsReceiversEntry 6 }
+
+
+-- ===========================================================================
+--
+-- ipmAgentAccessControlTable
+--
+-- ===========================================================================
+ipmAgentAccessControlTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IpmAgentAccessControlEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of managers which can access the device with private
+ community string."
+ ::= { ipmAgentConfig 8}
+
+ipmAgentAccessControlEntry OBJECT-TYPE
+ SYNTAX IpmAgentAccessControlEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The managers."
+ INDEX { accessIndex}
+ ::= { ipmAgentAccessControlTable 1 }
+
+IpmAgentAccessControlEntry ::=
+ SEQUENCE {
+ accessIndex
+ INTEGER,
+ accessControlAddr
+ IpAddress,
+ accessControlMode
+ INTEGER
+ }
+
+accessIndex OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to a access control entry."
+ ::= { ipmAgentAccessControlEntry 1 }
+
+accessControlAddr OBJECT-TYPE
+ SYNTAX IpAddress
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The IP address of the manager to access the device."
+ ::= { ipmAgentAccessControlEntry 2 }
+
+accessControlMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ permitted (1),
+ denied (2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Access type, only read/Write access type can change parameter
+ of the device."
+ ::= { ipmAgentAccessControlEntry 3 }
+
+ipmDeviceInlet OBJECT IDENTIFIER ::= { ipmDevice 1 }
+-- ===========================================================================
+--
+-- ipmDeviceInlet
+--
+-- Inlet Group
+--
+-- ===========================================================================
+ipmDeviceInletNumber OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The inlet number on this device."
+ ::= { ipmDeviceInlet 1}
+
+ipmDeviceInletConfigTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IpmDeviceInletConfigEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of inlet on this device."
+ ::= { ipmDeviceInlet 2}
+
+ipmDeviceInletConfigEntry OBJECT-TYPE
+ SYNTAX IpmDeviceInletConfigEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The inlet number of device."
+ INDEX { inletConfigIndex}
+ ::= { ipmDeviceInletConfigTable 1 }
+
+IpmDeviceInletConfigEntry ::=
+ SEQUENCE {
+ inletConfigIndex
+ INTEGER,
+ inletConfigDesc
+ DisplayString,
+ inletConfigVoltageHigh
+ INTEGER,
+ inletConfigVoltageHighAction
+ INTEGER,
+ inletConfigVoltageLow
+ INTEGER,
+ inletConfigVoltageLowAction
+ INTEGER,
+ inletConfigCurrentHigh
+ INTEGER,
+ inletConfigCurrentHighAction
+ INTEGER,
+ inletConfigFrequencyHigh
+ INTEGER,
+ inletConfigfrequencyHighAction
+ INTEGER,
+ inletConfigFrequencyLow
+ INTEGER,
+ inletConfigfrequencyLowAction
+ INTEGER
+ }
+
+inletConfigIndex OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to a access inlet configuration table."
+ ::= { ipmDeviceInletConfigEntry 1 }
+
+inletConfigDesc OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..31))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A Description of inlet of device."
+ ::= { ipmDeviceInletConfigEntry 2 }
+
+inletConfigVoltageHigh OBJECT-TYPE
+ SYNTAX INTEGER (1..65500) --
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The Inlet high voltage threshold, in volts."
+ ::= { ipmDeviceInletConfigEntry 3 }
+
+inletConfigVoltageHighAction OBJECT-TYPE
+ SYNTAX INTEGER {
+ outletsOff (1),
+ nothing (2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Reaction of the device when inlet voltage higher than set point."
+ ::= { ipmDeviceInletConfigEntry 4 }
+
+inletConfigVoltageLow OBJECT-TYPE
+ SYNTAX INTEGER (1..65500) --
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The Inlet low voltage threshold, in volts."
+ ::= { ipmDeviceInletConfigEntry 5 }
+
+inletConfigVoltageLowAction OBJECT-TYPE
+ SYNTAX INTEGER {
+ outletsOff (1),
+ nothing (2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Reaction of the device when inlet voltage lower than set point."
+ ::= { ipmDeviceInletConfigEntry 6 }
+
+inletConfigCurrentHigh OBJECT-TYPE
+ SYNTAX INTEGER (1..160) --
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The Inlet low voltage threshold, in 0.1 amps."
+ ::= { ipmDeviceInletConfigEntry 7 }
+
+inletConfigCurrentHighAction OBJECT-TYPE
+ SYNTAX INTEGER {
+ outletsOff (1),
+ nothing (2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Reaction of the device when inlet current higher than set point."
+ ::= { ipmDeviceInletConfigEntry 8 }
+
+inletConfigFrequencyHigh OBJECT-TYPE
+ SYNTAX INTEGER (1..65500) --
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The Inlet high frequency threshold, in hz."
+ ::= { ipmDeviceInletConfigEntry 9 }
+
+inletConfigfrequencyHighAction OBJECT-TYPE
+ SYNTAX INTEGER {
+ outletsOff (1),
+ nothing (2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Reaction of the device when inlet frequency higher than set point."
+ ::= { ipmDeviceInletConfigEntry 10 }
+
+inletConfigFrequencyLow OBJECT-TYPE
+ SYNTAX INTEGER (1..65500) --
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The Inlet low frequency threshold, in hz."
+ ::= { ipmDeviceInletConfigEntry 11 }
+
+inletConfigfrequencyLowAction OBJECT-TYPE
+ SYNTAX INTEGER {
+ outletsOff (1),
+ nothing (2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Reaction of the device when inlet frequency lower than set point."
+ ::= { ipmDeviceInletConfigEntry 12 }
+
+ipmDeviceInletStatusTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IpmDeviceInletStatusEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of inlet on this device."
+ ::= { ipmDeviceInlet 3}
+
+ipmDeviceInletStatusEntry OBJECT-TYPE
+ SYNTAX IpmDeviceInletStatusEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The inlet number of device."
+ INDEX { inletStatusIndex}
+ ::= { ipmDeviceInletStatusTable 1 }
+
+IpmDeviceInletStatusEntry ::=
+ SEQUENCE {
+ inletStatusIndex
+ INTEGER,
+ inletStatusVoltage
+ INTEGER,
+ inletStatusCurrent
+ INTEGER,
+ inletStatusFrequency
+ INTEGER,
+ inletStatusKwatt
+ INTEGER,
+ inletStatusWH
+ INTEGER
+ }
+
+inletStatusIndex OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to a access inlet configuration table."
+ ::= { ipmDeviceInletStatusEntry 1 }
+
+inletStatusVoltage OBJECT-TYPE
+ SYNTAX INTEGER (1..65500) --
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The Inlet Voltage in 0.1 volts"
+ ::= { ipmDeviceInletStatusEntry 2 }
+
+inletStatusCurrent OBJECT-TYPE
+ SYNTAX INTEGER (0..65500) --
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The Inlet Current in 0.001 Amp."
+ ::= { ipmDeviceInletStatusEntry 3 }
+
+inletStatusFrequency OBJECT-TYPE
+ SYNTAX INTEGER (1..65500) --
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The Inlet Frequency in 0.1 Hz"
+ ::= { ipmDeviceInletStatusEntry 4 }
+
+inletStatusKwatt OBJECT-TYPE
+ SYNTAX INTEGER (0..65500) --
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The Inlet Kwatt in 0.1 KW/H"
+ ::= { ipmDeviceInletStatusEntry 5 }
+
+inletStatusWH OBJECT-TYPE
+ SYNTAX INTEGER (1..65500) --
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The Inlet Kwatt in 0.1 W/H"
+ ::= { ipmDeviceInletStatusEntry 6 }
+
+
+inletWattReset OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(1),
+ inlet1(2),
+ inlet2(3)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Reset inlet kw."
+ ::= { ipmDeviceInlet 4}
+
+
+ipmDeviceOutlet OBJECT IDENTIFIER ::= { ipmDevice 2 }
+-- ===========================================================================
+--
+-- ipmDeviceOutlet
+--
+-- Inlet Group
+--
+-- ===========================================================================
+ipmDeviceOutletNumber OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The outlet number on this device."
+ ::= { ipmDeviceOutlet 1}
+
+ipmDeviceOutletConfigTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IpmDeviceOutletConfigEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of outlet on this device."
+ ::= { ipmDeviceOutlet 2}
+
+ipmDeviceOutletConfigEntry OBJECT-TYPE
+ SYNTAX IpmDeviceOutletConfigEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The inlet number of device."
+ INDEX { inletConfigIndex}
+ ::= { ipmDeviceOutletConfigTable 1 }
+
+IpmDeviceOutletConfigEntry ::=
+ SEQUENCE {
+ outletConfigIndex
+ INTEGER,
+ outletConfigDesc
+ DisplayString,
+ outletConfigLocation
+ DisplayString,
+ outletConfigOnDelay
+ INTEGER,
+ outletConfigOffDelay
+ INTEGER,
+ outletConfigCurrentHigh
+ INTEGER,
+ outletConfigCurrentHighAction
+ INTEGER
+ }
+
+outletConfigIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to a access inlet configuration table."
+ ::= { ipmDeviceOutletConfigEntry 1 }
+
+outletConfigDesc OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..31))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A Description of outlet of device."
+ ::= { ipmDeviceOutletConfigEntry 2 }
+
+outletConfigLocation OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..31))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Location of device connectted to this outlet."
+ ::= { ipmDeviceOutletConfigEntry 3 }
+
+outletConfigOnDelay OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The delay time before turn on tis outlet, in seconds."
+ ::= { ipmDeviceOutletConfigEntry 4 }
+
+outletConfigOffDelay OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The delay time before turn off tis outlet, in seconds."
+ ::= { ipmDeviceOutletConfigEntry 5 }
+
+outletConfigCurrentHigh OBJECT-TYPE
+ SYNTAX INTEGER (1..65500) --
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The outlet high current threshold, in amp."
+ ::= { ipmDeviceOutletConfigEntry 6 }
+
+outletConfigCurrentHighAction OBJECT-TYPE
+ SYNTAX INTEGER {
+ outletOff (1),
+ nothing (2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Reaction of the device when outlet current higher than set point."
+ ::= { ipmDeviceOutletConfigEntry 7 }
+
+
+
+ipmDeviceOutletStatusTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IpmDeviceOutletStatusEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of outlet on this device."
+ ::= { ipmDeviceOutlet 3}
+
+ipmDeviceOutletStatusEntry OBJECT-TYPE
+ SYNTAX IpmDeviceOutletStatusEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The outlet number of device."
+ INDEX { outletStatusIndex}
+ ::= { ipmDeviceOutletStatusTable 1 }
+
+IpmDeviceOutletStatusEntry ::=
+ SEQUENCE {
+ outletStatusIndex
+ INTEGER,
+ outletStatusStatus
+ INTEGER,
+ outletStatusCurrent
+ INTEGER,
+ outletStatusKwatt
+ INTEGER,
+ outletStatusWH
+ INTEGER,
+ outletStatusStateTime
+ INTEGER,
+ outletStatusTimeToGo
+ INTEGER
+ }
+
+outletStatusIndex OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to a access outlet configuration table."
+ ::= { ipmDeviceOutletStatusEntry 1 }
+
+outletStatusStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknow (1),
+ outletOff (2),
+ outletOn (3),
+ outletOffToOn (4),
+ outletOnToOff (5),
+ outletCycling (6)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Outlet state"
+ ::= { ipmDeviceOutletStatusEntry 2 }
+
+outletStatusCurrent OBJECT-TYPE
+ SYNTAX INTEGER (0..65500) --
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The outlet Current in 0.001 Amp."
+ ::= { ipmDeviceOutletStatusEntry 3 }
+
+outletStatusKwatt OBJECT-TYPE
+ SYNTAX INTEGER (0..65500) --
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The outlet Kwatt in 0.001 KW/H."
+ ::= { ipmDeviceOutletStatusEntry 4 }
+
+outletStatusWH OBJECT-TYPE
+ SYNTAX INTEGER (0..65500) --
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The outlet Watt in 0.1 W/H."
+ ::= { ipmDeviceOutletStatusEntry 5 }
+
+outletStatusStateTime OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Time in seconds since the outlet changed to current state."
+ ::= { ipmDeviceOutletStatusEntry 6 }
+
+outletStatusTimeToGo OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Remain time the outlet state will be changed by agent, in seconds"
+ ::= { ipmDeviceOutletStatusEntry 7 }
+
+ipmDeviceOutletControlTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IpmDeviceOutletControlEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of outlet on this device."
+ ::= { ipmDeviceOutlet 4}
+
+ipmDeviceOutletControlEntry OBJECT-TYPE
+ SYNTAX IpmDeviceOutletControlEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The outlet number of device."
+ INDEX { outletControlIndex}
+ ::= { ipmDeviceOutletControlTable 1 }
+
+IpmDeviceOutletControlEntry ::=
+ SEQUENCE {
+ outletControlIndex
+ INTEGER,
+ outletControlControl
+ INTEGER
+ }
+
+outletControlIndex OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to a access outlet configuration table."
+ ::= { ipmDeviceOutletControlEntry 1 }
+
+outletControlControl OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(1),
+ cancelAction(2),
+ onImmediately(3),
+ offImmediately(4),
+ cycleImmediately(5),
+ onByActionTimer(6),
+ offByActionTimer(7),
+ cycleByActionTimer(8),
+ onThenOffByActionTimers(9),
+ offThenOnByActionTimers(10)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Set to control the outlet perform action as requested."
+ ::= { ipmDeviceOutletControlEntry 2 }
+
+ipmDeviceOutletControlAll OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(1),
+ cancelAction(2),
+ onImmediately(3),
+ offImmediately(4),
+ cycleImmediately(5),
+ onByActionTimers(6),
+ offByActionTimers(7),
+ cycleByActionTimers(8),
+ onThenOffByActionTimers(9),
+ offThenOnByActionTimers(10)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Set to control all outlets perform action as requested."
+ ::= { ipmDeviceOutlet 5}
+
+ipmDeviceOutletWattReset OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(1),
+ outleta(2),
+ outletb(3),
+ outletc(4),
+ outletd(5),
+ outlete(6),
+ outletf(7),
+
+ outletg(8),
+ outleth(9),
+ outleti(10),
+ outletj(11),
+ outletk(12),
+ outletl(13)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Reset outlet kw."
+ ::= { ipmDeviceOutlet 6}
+
+
+ipmDeviceCcOut OBJECT IDENTIFIER ::= { ipmDevice 3 }
+-- ===========================================================================
+--
+-- ipmDeviceCCOut
+--
+-- Contact Closure Output Group
+--
+-- ===========================================================================
+ipmDeviceCcOutNumber OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The contact closure output number on this device."
+ ::= { ipmDeviceCcOut 1}
+
+ipmDeviceCcOutConfigTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IpmDeviceCcOutConfigEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of contact closure output on this device."
+ ::= { ipmDeviceCcOut 2}
+
+ipmDeviceCcOutConfigEntry OBJECT-TYPE
+ SYNTAX IpmDeviceCcOutConfigEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The CC number of device."
+ INDEX { ccOutConfigIndex}
+ ::= { ipmDeviceCcOutConfigTable 1 }
+
+IpmDeviceCcOutConfigEntry ::=
+ SEQUENCE {
+ ccOutConfigIndex
+ INTEGER,
+ ccOutConfigDesc
+ DisplayString,
+ ccOutConfigEventAction
+ INTEGER,
+ ccOutConfigCloseDelay
+ INTEGER,
+ ccOutConfigOpenDelay
+ INTEGER
+ }
+
+ccOutConfigIndex OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to access contact closure output configuration table."
+ ::= { ipmDeviceCcOutConfigEntry 1 }
+
+ccOutConfigDesc OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..31))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A Description of a contact closure output of device."
+ ::= { ipmDeviceCcOutConfigEntry 2 }
+
+ccOutConfigEventAction OBJECT-TYPE
+ SYNTAX INTEGER {
+ yes (1),
+ no (2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Enable/disble the contact closure output to react to events."
+ ::= { ipmDeviceCcOutConfigEntry 3 }
+
+ccOutConfigCloseDelay OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The delay time in seconds when the contact closure output set to close."
+ ::= { ipmDeviceCcOutConfigEntry 4 }
+
+ccOutConfigOpenDelay OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The delay time in seconds when the contact closure output set to open."
+ ::= { ipmDeviceCcOutConfigEntry 5 }
+
+ipmDeviceCcOutStatusTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IpmDeviceCcOutStatusEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of contact closure output on this device."
+ ::= { ipmDeviceCcOut 3}
+
+ipmDeviceCcOutStatusEntry OBJECT-TYPE
+ SYNTAX IpmDeviceCcOutStatusEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The CC number of device."
+ INDEX { ccOutStatusIndex}
+ ::= { ipmDeviceCcOutStatusTable 1 }
+
+IpmDeviceCcOutStatusEntry ::=
+ SEQUENCE {
+ ccOutStatusIndex
+ INTEGER,
+ ccOutStatusStatus
+ INTEGER,
+ ccOutStatusTimeOnState
+ INTEGER
+ }
+
+ccOutStatusIndex OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to access contact closure output configuration table."
+ ::= { ipmDeviceCcOutStatusEntry 1 }
+
+ccOutStatusStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ closed (1),
+ open (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "State of a contact closure output of device."
+ ::= { ipmDeviceCcOutStatusEntry 2 }
+
+ccOutStatusTimeOnState OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Time in seconds since the contact closure output changed to current state."
+ ::= { ipmDeviceCcOutStatusEntry 3 }
+
+ipmDeviceCcOutControlTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IpmDeviceCcOutControlEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of contact closure output on this device."
+ ::= { ipmDeviceCcOut 4}
+
+ipmDeviceCcOutControlEntry OBJECT-TYPE
+ SYNTAX IpmDeviceCcOutControlEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The outlet number of device."
+ INDEX { ccOutControlIndex}
+ ::= { ipmDeviceCcOutControlTable 1 }
+
+IpmDeviceCcOutControlEntry ::=
+ SEQUENCE {
+ ccOutControlIndex
+ INTEGER,
+ ccOutControlControl
+ INTEGER
+ }
+
+ccOutControlIndex OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to a access contact closure output configuration table."
+ ::= { ipmDeviceCcOutControlEntry 1 }
+
+ccOutControlControl OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(1),
+ cancelAction(2),
+ closeImmediately(3),
+ openImmediately(4),
+ cycleImmediately(5),
+ closeByCloseTimer(6),
+ openByOpenTimer(7),
+ cycleByActionTimer(8),
+ closeThenOpenByActionTimers(9),
+ openThenCloseByActionTimers(10)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Set to control the contact closure output perform action as requested."
+ ::= { ipmDeviceCcOutControlEntry 2 }
+
+ipmSlaveState OBJECT IDENTIFIER ::= { ipmSlave 1 }
+-- ===========================================================================
+--
+-- ipmSlaveState
+--
+-- Daisy Chain Device Group
+--
+-- ===========================================================================
+--
+
+ipmSlaveStateTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IpmSlaveStateEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of outlet on this device."
+ ::= { ipmSlaveState 1}
+
+ipmSlaveStateEntry OBJECT-TYPE
+ SYNTAX IpmSlaveStateEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The outlet number of device."
+ INDEX { slaveStateIndex}
+ ::= { ipmSlaveStateTable 1 }
+
+IpmSlaveStateEntry ::=
+ SEQUENCE {
+ slaveStateIndex
+ INTEGER,
+ slaveStateControl01
+ INTEGER
+ }
+
+slaveStateIndex OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to a access outlet configuration table."
+ ::= { ipmSlaveStateEntry 1 }
+
+slaveStateControl01 OBJECT-TYPE
+ SYNTAX INTEGER {
+ disconnected(1),
+ connected(2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Set to control the outlet perform action as requested to slave outlet A"
+ ::= { ipmSlaveStateEntry 2 }
+
+ipmSlaveInlet OBJECT IDENTIFIER ::= { ipmSlave 2 }
+-- ===========================================================================
+--
+-- ipmSlaveAllDevice
+--
+-- Daisy Chain Device Group
+--
+-- ===========================================================================
+
+ipmSlaveInletStatus OBJECT IDENTIFIER ::= { ipmSlaveInlet 1 }
+-- ===========================================================================
+--
+-- ipmSlaveAllDevice
+--
+-- Daisy Chain Device Group
+--
+-- ===========================================================================
+
+
+ipmDeviceSlaveInletStatusTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IpmDeviceSlaveInletStatusEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of inlet on this device."
+ ::= { ipmSlaveInletStatus 1}
+
+ipmDeviceSlaveInletStatusEntry OBJECT-TYPE
+ SYNTAX IpmDeviceSlaveInletStatusEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The inlet number of device."
+ INDEX { inletStatusIndex}
+ ::= { ipmDeviceSlaveInletStatusTable 1 }
+
+IpmDeviceSlaveInletStatusEntry ::=
+ SEQUENCE {
+ inletSlaveStatusIndex
+ INTEGER,
+ inletSlaveStatusVoltage
+ INTEGER,
+ inletSlaveStatusCurrent
+ INTEGER,
+ inletSlaveStatusFrequency
+ INTEGER,
+ inletSlaveStatusKwatt
+ INTEGER,
+ inletSlaveStatusWH
+ INTEGER,
+ inletSlaveStatusVoltage2
+ INTEGER,
+ inletSlaveStatusCurrent2
+ INTEGER,
+ inletSlaveStatusFrequency2
+ INTEGER,
+ inletSlaveStatusKwatt2
+ INTEGER,
+ inletSlaveStatusWH2
+ INTEGER
+ }
+
+inletSlaveStatusIndex OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to a access inlet configuration table."
+ ::= { ipmDeviceSlaveInletStatusEntry 1 }
+
+inletSlaveStatusVoltage OBJECT-TYPE
+ SYNTAX INTEGER (1..65500) --
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The Inlet Voltage in 0.1 volts"
+ ::= { ipmDeviceSlaveInletStatusEntry 2 }
+
+inletSlaveStatusCurrent OBJECT-TYPE
+ SYNTAX INTEGER (0..65500) --
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The Inlet Current in 0.001 Amp."
+ ::= { ipmDeviceSlaveInletStatusEntry 3 }
+
+inletSlaveStatusFrequency OBJECT-TYPE
+ SYNTAX INTEGER (1..65500) --
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The Inlet Frequency in 0.1 Hz"
+ ::= { ipmDeviceSlaveInletStatusEntry 4 }
+
+inletSlaveStatusKwatt OBJECT-TYPE
+ SYNTAX INTEGER (0..65500) --
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The Inlet Kwatt in 0.001 KW/H"
+ ::= { ipmDeviceSlaveInletStatusEntry 5 }
+
+inletSlaveStatusWH OBJECT-TYPE
+ SYNTAX INTEGER (1..65500) --
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The Inlet Kwatt in 0.001 KW/H"
+ ::= { ipmDeviceSlaveInletStatusEntry 6 }
+
+inletSlaveStatusVoltage2 OBJECT-TYPE
+ SYNTAX INTEGER (1..65500) --
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The Inlet Voltage in 0.1 volts"
+ ::= { ipmDeviceSlaveInletStatusEntry 7 }
+
+inletSlaveStatusCurrent2 OBJECT-TYPE
+ SYNTAX INTEGER (0..65500) --
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The Inlet Current in 0.001 Amp."
+ ::= { ipmDeviceSlaveInletStatusEntry 8 }
+
+inletSlaveStatusFrequency2 OBJECT-TYPE
+ SYNTAX INTEGER (1..65500) --
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The Inlet Frequency in 0.1 Hz"
+ ::= { ipmDeviceSlaveInletStatusEntry 9 }
+
+inletSlaveStatusKwatt2 OBJECT-TYPE
+ SYNTAX INTEGER (0..65500) --
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The Inlet Kwatt in 0.001 KW/H"
+ ::= { ipmDeviceSlaveInletStatusEntry 10 }
+
+inletSlaveStatusWH2 OBJECT-TYPE
+ SYNTAX INTEGER (1..65500) --
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The Inlet Kwatt in 0.001 KW/H"
+ ::= { ipmDeviceSlaveInletStatusEntry 11 }
+
+ipmSlaveInletConfig OBJECT IDENTIFIER ::= { ipmSlaveInlet 2 }
+-- ===========================================================================
+--
+-- ipmSlaveAllDevice
+--
+-- Daisy Chain Device Group
+--
+-- ===========================================================================
+
+
+ipmDeviceslaveInletConfigTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IpmDeviceslaveInletConfigEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of inlet on this device."
+ ::= { ipmSlaveInletConfig 1}
+
+ipmDeviceslaveInletConfigEntry OBJECT-TYPE
+ SYNTAX IpmDeviceslaveInletConfigEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The inlet number of device."
+ INDEX { slaveInletConfigIndex}
+ ::= { ipmDeviceslaveInletConfigTable 1 }
+
+IpmDeviceslaveInletConfigEntry ::=
+ SEQUENCE {
+ slaveInletConfigIndex
+ INTEGER,
+ slaveInletConfigVoltageHigh
+ INTEGER,
+ slaveInletConfigVoltageLow
+ INTEGER,
+ slaveInlet2ConfigVoltageHigh
+ INTEGER,
+ slaveInlet2ConfigVoltageLow
+ INTEGER
+ }
+
+slaveInletConfigIndex OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to a access inlet configuration table."
+ ::= { ipmDeviceslaveInletConfigEntry 1 }
+
+
+slaveInletConfigVoltageHigh OBJECT-TYPE
+ SYNTAX INTEGER (1..65500) --
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The Inlet high voltage threshold, in volts."
+ ::= { ipmDeviceslaveInletConfigEntry 2 }
+
+
+slaveInletConfigVoltageLow OBJECT-TYPE
+ SYNTAX INTEGER (1..65500) --
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The Inlet low voltage threshold, in volts."
+ ::= { ipmDeviceslaveInletConfigEntry 3 }
+
+
+slaveInlet2ConfigVoltageHigh OBJECT-TYPE
+ SYNTAX INTEGER (1..65500) --
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The Inlet 2 high voltage threshold, in volts."
+ ::= { ipmDeviceslaveInletConfigEntry 4 }
+
+slaveInlet2ConfigVoltageLow OBJECT-TYPE
+ SYNTAX INTEGER (1..65500) --
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The Inlet low voltage threshold, in volts."
+ ::= { ipmDeviceslaveInletConfigEntry 5 }
+
+
+ipmSlaveOutlet OBJECT IDENTIFIER ::= { ipmSlave 3 }
+-- ===========================================================================
+--
+-- ipmSlaveAllDevice
+--
+-- Daisy Chain Device Group
+--
+-- ===========================================================================
+
+ipmSlaveOutletConfig OBJECT IDENTIFIER ::= { ipmSlaveOutlet 1 }
+-- ===========================================================================
+--
+-- ipmOutletConfig
+--
+-- Outlet Config Group
+--
+-- ===========================================================================
+
+--
+-- Outlet Name Description
+--
+
+ipmSlaveDeviceOutletNameTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IpmSlaveDeviceOutletNameEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of outlet on this device."
+ ::= { ipmSlaveOutletConfig 1}
+
+ipmSlaveDeviceOutletNameEntry OBJECT-TYPE
+ SYNTAX IpmSlaveDeviceOutletNameEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The outlet number of device."
+ INDEX { slaveOutletNameIndex}
+ ::= { ipmSlaveDeviceOutletNameTable 1 }
+
+IpmSlaveDeviceOutletNameEntry ::=
+ SEQUENCE {
+ slaveOutletNameIndex
+ INTEGER,
+ slaveOutletName01
+ DisplayString,
+ slaveOutletName02
+ DisplayString,
+ slaveOutletName03
+ DisplayString,
+ slaveOutletName04
+ DisplayString,
+ slaveOutletName05
+ DisplayString,
+ slaveOutletName06
+ DisplayString,
+ slaveOutletName07
+ DisplayString,
+ slaveOutletName08
+ DisplayString,
+ slaveOutletName09
+ DisplayString,
+ slaveOutletName10
+ DisplayString,
+ slaveOutletName11
+ DisplayString,
+ slaveOutletName12
+ DisplayString
+ }
+
+slaveOutletNameIndex OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to a access outlet configuration table."
+ ::= { ipmSlaveDeviceOutletNameEntry 1 }
+
+slaveOutletName01 OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..31))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A Description of a outlet name of device."
+ ::= { ipmSlaveDeviceOutletNameEntry 2 }
+
+slaveOutletName02 OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..31))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A Description of a outlet name of device."
+ ::= { ipmSlaveDeviceOutletNameEntry 3 }
+
+slaveOutletName03 OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..31))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A Description of a outlet name of device."
+ ::= { ipmSlaveDeviceOutletNameEntry 4 }
+
+slaveOutletName04 OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..31))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A Description of a outlet name of device."
+ ::= { ipmSlaveDeviceOutletNameEntry 5 }
+
+slaveOutletName05 OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..31))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A Description of a outlet name of device."
+ ::= { ipmSlaveDeviceOutletNameEntry 6 }
+
+slaveOutletName06 OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..31))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A Description of a outlet name of device."
+ ::= { ipmSlaveDeviceOutletNameEntry 7 }
+
+slaveOutletName07 OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..31))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A Description of a outlet name of device."
+ ::= { ipmSlaveDeviceOutletNameEntry 8 }
+
+slaveOutletName08 OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..31))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A Description of a outlet name of device."
+ ::= { ipmSlaveDeviceOutletNameEntry 9 }
+
+slaveOutletName09 OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..31))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A Description of a outlet name of device."
+ ::= { ipmSlaveDeviceOutletNameEntry 10 }
+
+slaveOutletName10 OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..31))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A Description of a outlet name of device."
+ ::= { ipmSlaveDeviceOutletNameEntry 11 }
+
+slaveOutletName11 OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..31))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A Description of a outlet name of device."
+ ::= { ipmSlaveDeviceOutletNameEntry 12 }
+
+slaveOutletName12 OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..31))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A Description of a outlet name of device."
+ ::= { ipmSlaveDeviceOutletNameEntry 13 }
+
+-- ===============================
+-- Outlet Location Description
+-- ===============================
+
+
+ipmSlaveDeviceOutletLocationTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IpmSlaveDeviceOutletLocationEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of outlet on this device."
+ ::= { ipmSlaveOutletConfig 2}
+
+ipmSlaveDeviceOutletLocationEntry OBJECT-TYPE
+ SYNTAX IpmSlaveDeviceOutletLocationEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The outlet number of device."
+ INDEX { slaveOutletLocationIndex}
+ ::= { ipmSlaveDeviceOutletLocationTable 1 }
+
+IpmSlaveDeviceOutletLocationEntry ::=
+ SEQUENCE {
+ slaveOutletLocationIndex
+ INTEGER,
+ slaveOutletLocation01
+ DisplayString,
+ slaveOutletLocation02
+ DisplayString,
+ slaveOutletLocation03
+ DisplayString,
+ slaveOutletLocation04
+ DisplayString,
+ slaveOutletLocation05
+ DisplayString,
+ slaveOutletLocation06
+ DisplayString,
+ slaveOutletLocation07
+ DisplayString,
+ slaveOutletLocation08
+ DisplayString,
+ slaveOutletLocation09
+ DisplayString,
+ slaveOutletLocation10
+ DisplayString,
+ slaveOutletLocation11
+ DisplayString,
+ slaveOutletLocation12
+ DisplayString
+ }
+
+slaveOutletLocationIndex OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to a access outlet configuration table."
+ ::= { ipmSlaveDeviceOutletLocationEntry 1 }
+
+slaveOutletLocation01 OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..31))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A Description of a outlet name of device."
+ ::= { ipmSlaveDeviceOutletLocationEntry 2 }
+
+slaveOutletLocation02 OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..31))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A Description of a outlet name of device."
+ ::= { ipmSlaveDeviceOutletLocationEntry 3 }
+
+slaveOutletLocation03 OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..31))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A Description of a outlet name of device."
+ ::= { ipmSlaveDeviceOutletLocationEntry 4 }
+
+slaveOutletLocation04 OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..31))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A Description of a outlet name of device."
+ ::= { ipmSlaveDeviceOutletLocationEntry 5 }
+
+slaveOutletLocation05 OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..31))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A Description of a outlet name of device."
+ ::= { ipmSlaveDeviceOutletLocationEntry 6 }
+
+slaveOutletLocation06 OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..31))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A Description of a outlet name of device."
+ ::= { ipmSlaveDeviceOutletLocationEntry 7 }
+
+slaveOutletLocation07 OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..31))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A Description of a outlet name of device."
+ ::= { ipmSlaveDeviceOutletLocationEntry 8 }
+
+slaveOutletLocation08 OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..31))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A Description of a outlet name of device."
+ ::= { ipmSlaveDeviceOutletLocationEntry 9 }
+
+slaveOutletLocation09 OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..31))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A Description of a outlet name of device."
+ ::= { ipmSlaveDeviceOutletLocationEntry 10 }
+
+slaveOutletLocation10 OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..31))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A Description of a outlet name of device."
+ ::= { ipmSlaveDeviceOutletLocationEntry 11 }
+
+slaveOutletLocation11 OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..31))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A Description of a outlet name of device."
+ ::= { ipmSlaveDeviceOutletLocationEntry 12 }
+
+slaveOutletLocation12 OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..31))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A Description of a outlet name of device."
+ ::= { ipmSlaveDeviceOutletLocationEntry 13 }
+
+-- ==========================================
+-- Outlet On Delay Time
+-- ==========================================
+
+ipmSlaveDeviceOutletOnTimeTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IpmSlaveDeviceOutletOnTimeEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of outlet on this device."
+ ::= { ipmSlaveOutletConfig 3}
+
+ipmSlaveDeviceOutletOnTimeEntry OBJECT-TYPE
+ SYNTAX IpmSlaveDeviceOutletOnTimeEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The outlet number of device."
+ INDEX { slaveOutletOnTimeIndex}
+ ::= { ipmSlaveDeviceOutletOnTimeTable 1 }
+
+IpmSlaveDeviceOutletOnTimeEntry ::=
+ SEQUENCE {
+ slaveOutletOnTimeIndex
+ INTEGER,
+ slaveOutletOnTime01
+ INTEGER,
+ slaveOutletOnTime02
+ INTEGER,
+ slaveOutletOnTime03
+ INTEGER,
+ slaveOutletOnTime04
+ INTEGER,
+ slaveOutletOnTime05
+ INTEGER,
+ slaveOutletOnTime06
+ INTEGER,
+ slaveOutletOnTime07
+ INTEGER,
+ slaveOutletOnTime08
+ INTEGER,
+ slaveOutletOnTime09
+ INTEGER,
+ slaveOutletOnTime10
+ INTEGER,
+ slaveOutletOnTime11
+ INTEGER,
+ slaveOutletOnTime12
+ INTEGER
+ }
+
+slaveOutletOnTimeIndex OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to a access outlet configuration table."
+ ::= { ipmSlaveDeviceOutletOnTimeEntry 1 }
+
+slaveOutletOnTime01 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The delay time before turn on tis outlet, in seconds."
+ ::= { ipmSlaveDeviceOutletOnTimeEntry 2 }
+
+slaveOutletOnTime02 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The delay time before turn on tis outlet, in seconds."
+ ::= { ipmSlaveDeviceOutletOnTimeEntry 3 }
+
+slaveOutletOnTime03 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The delay time before turn on tis outlet, in seconds."
+ ::= { ipmSlaveDeviceOutletOnTimeEntry 4 }
+
+slaveOutletOnTime04 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The delay time before turn on tis outlet, in seconds."
+ ::= { ipmSlaveDeviceOutletOnTimeEntry 5 }
+
+slaveOutletOnTime05 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The delay time before turn on tis outlet, in seconds."
+ ::= { ipmSlaveDeviceOutletOnTimeEntry 6 }
+
+slaveOutletOnTime06 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The delay time before turn on tis outlet, in seconds."
+ ::= { ipmSlaveDeviceOutletOnTimeEntry 7 }
+
+slaveOutletOnTime07 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The delay time before turn on tis outlet, in seconds."
+ ::= { ipmSlaveDeviceOutletOnTimeEntry 8 }
+
+slaveOutletOnTime08 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The delay time before turn on tis outlet, in seconds."
+ ::= { ipmSlaveDeviceOutletOnTimeEntry 9 }
+
+slaveOutletOnTime09 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The delay time before turn on tis outlet, in seconds."
+ ::= { ipmSlaveDeviceOutletOnTimeEntry 10 }
+
+slaveOutletOnTime10 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The delay time before turn on tis outlet, in seconds."
+ ::= { ipmSlaveDeviceOutletOnTimeEntry 11 }
+
+
+slaveOutletOnTime11 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The delay time before turn on tis outlet, in seconds."
+ ::= { ipmSlaveDeviceOutletOnTimeEntry 12 }
+
+slaveOutletOnTime12 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The delay time before turn on tis outlet, in seconds."
+ ::= { ipmSlaveDeviceOutletOnTimeEntry 13 }
+
+-- ==========================================
+-- Outlet Off Delay Time
+-- ==========================================
+
+ipmSlaveDeviceOutletOffTimeTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IpmSlaveDeviceOutletOffTimeEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of outlet on this device."
+ ::= { ipmSlaveOutletConfig 4}
+
+ipmSlaveDeviceOutletOffTimeEntry OBJECT-TYPE
+ SYNTAX IpmSlaveDeviceOutletOffTimeEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The outlet number of device."
+ INDEX { slaveOutletOffTimeIndex}
+ ::= { ipmSlaveDeviceOutletOffTimeTable 1 }
+
+IpmSlaveDeviceOutletOffTimeEntry ::=
+ SEQUENCE {
+ slaveOutletOffTimeIndex
+ INTEGER,
+ slaveOutletOffTime01
+ INTEGER,
+ slaveOutletOffTime02
+ INTEGER,
+ slaveOutletOffTime03
+ INTEGER,
+ slaveOutletOffTime04
+ INTEGER,
+ slaveOutletOffTime05
+ INTEGER,
+ slaveOutletOffTime06
+ INTEGER,
+ slaveOutletOffTime07
+ INTEGER,
+ slaveOutletOffTime08
+ INTEGER,
+ slaveOutletOffTime09
+ INTEGER,
+ slaveOutletOffTime10
+ INTEGER,
+ slaveOutletOffTime11
+ INTEGER,
+ slaveOutletOffTime12
+ INTEGER
+ }
+
+slaveOutletOffTimeIndex OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to a access outlet configuration table."
+ ::= { ipmSlaveDeviceOutletOffTimeEntry 1 }
+
+slaveOutletOffTime01 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The delay time before turn on tis outlet, in seconds."
+ ::= { ipmSlaveDeviceOutletOffTimeEntry 2 }
+
+slaveOutletOffTime02 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The delay time before turn on tis outlet, in seconds."
+ ::= { ipmSlaveDeviceOutletOffTimeEntry 3 }
+
+slaveOutletOffTime03 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The delay time before turn on tis outlet, in seconds."
+ ::= { ipmSlaveDeviceOutletOffTimeEntry 4 }
+
+slaveOutletOffTime04 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The delay time before turn on tis outlet, in seconds."
+ ::= { ipmSlaveDeviceOutletOffTimeEntry 5 }
+
+slaveOutletOffTime05 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The delay time before turn on tis outlet, in seconds."
+ ::= { ipmSlaveDeviceOutletOffTimeEntry 6 }
+
+slaveOutletOffTime06 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The delay time before turn on tis outlet, in seconds."
+ ::= { ipmSlaveDeviceOutletOffTimeEntry 7 }
+
+slaveOutletOffTime07 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The delay time before turn on tis outlet, in seconds."
+ ::= { ipmSlaveDeviceOutletOffTimeEntry 8 }
+
+slaveOutletOffTime08 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The delay time before turn on tis outlet, in seconds."
+ ::= { ipmSlaveDeviceOutletOffTimeEntry 9 }
+
+slaveOutletOffTime09 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The delay time before turn on tis outlet, in seconds."
+ ::= { ipmSlaveDeviceOutletOffTimeEntry 10 }
+
+slaveOutletOffTime10 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The delay time before turn on tis outlet, in seconds."
+ ::= { ipmSlaveDeviceOutletOffTimeEntry 11 }
+
+
+slaveOutletOffTime11 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The delay time before turn on tis outlet, in seconds."
+ ::= { ipmSlaveDeviceOutletOffTimeEntry 12 }
+
+slaveOutletOffTime12 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The delay time before turn on tis outlet, in seconds."
+ ::= { ipmSlaveDeviceOutletOffTimeEntry 13 }
+
+
+-- ==========================================
+-- Outlet Current TH
+-- ==========================================
+
+ipmSlaveDeviceOutletCurrThTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IpmSlaveDeviceOutletCurrThEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of outlet on this device."
+ ::= { ipmSlaveOutletConfig 5}
+
+ipmSlaveDeviceOutletCurrThEntry OBJECT-TYPE
+ SYNTAX IpmSlaveDeviceOutletCurrThEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The outlet number of device."
+ INDEX { slaveOutletCurrThIndex}
+ ::= { ipmSlaveDeviceOutletCurrThTable 1 }
+
+IpmSlaveDeviceOutletCurrThEntry ::=
+ SEQUENCE {
+ slaveOutletCurrThIndex
+ INTEGER,
+ slaveOutletCurrTh01
+ INTEGER,
+ slaveOutletCurrTh02
+ INTEGER,
+ slaveOutletCurrTh03
+ INTEGER,
+ slaveOutletCurrTh04
+ INTEGER,
+ slaveOutletCurrTh05
+ INTEGER,
+ slaveOutletCurrTh06
+ INTEGER,
+ slaveOutletCurrTh07
+ INTEGER,
+ slaveOutletCurrTh08
+ INTEGER,
+ slaveOutletCurrTh09
+ INTEGER,
+ slaveOutletCurrTh10
+ INTEGER,
+ slaveOutletCurrTh11
+ INTEGER,
+ slaveOutletCurrTh12
+ INTEGER
+ }
+
+slaveOutletCurrThIndex OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to a access outlet configuration table."
+ ::= { ipmSlaveDeviceOutletCurrThEntry 1 }
+
+slaveOutletCurrTh01 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The Outlet Current Threshold ,in 0.1 Amp."
+ ::= { ipmSlaveDeviceOutletCurrThEntry 2 }
+
+slaveOutletCurrTh02 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The Outlet Current Threshold ,in 0.1 Amp."
+ ::= { ipmSlaveDeviceOutletCurrThEntry 3 }
+
+slaveOutletCurrTh03 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The Outlet Current Threshold ,in 0.1 Amp."
+ ::= { ipmSlaveDeviceOutletCurrThEntry 4 }
+
+slaveOutletCurrTh04 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The Outlet Current Threshold ,in 0.1 Amp."
+ ::= { ipmSlaveDeviceOutletCurrThEntry 5 }
+
+slaveOutletCurrTh05 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The Outlet Current Threshold ,in 0.1 Amp."
+ ::= { ipmSlaveDeviceOutletCurrThEntry 6 }
+
+slaveOutletCurrTh06 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The Outlet Current Threshold ,in 0.1 Amp."
+ ::= { ipmSlaveDeviceOutletCurrThEntry 7 }
+
+slaveOutletCurrTh07 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The Outlet Current Threshold ,in 0.1 Amp."
+ ::= { ipmSlaveDeviceOutletCurrThEntry 8 }
+
+slaveOutletCurrTh08 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The Outlet Current Threshold ,in 0.1 Amp."
+ ::= { ipmSlaveDeviceOutletCurrThEntry 9 }
+
+slaveOutletCurrTh09 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The Outlet Current Threshold ,in 0.1 Amp."
+ ::= { ipmSlaveDeviceOutletCurrThEntry 10 }
+
+slaveOutletCurrTh10 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The Outlet Current Threshold ,in 0.1 Amp."
+ ::= { ipmSlaveDeviceOutletCurrThEntry 11 }
+
+
+slaveOutletCurrTh11 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The Outlet Current Threshold ,in 0.1 Amp."
+ ::= { ipmSlaveDeviceOutletCurrThEntry 12 }
+
+slaveOutletCurrTh12 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The Outlet Current Threshold ,in 0.1 Amp."
+ ::= { ipmSlaveDeviceOutletCurrThEntry 13 }
+
+ipmSlaveOutletStatus OBJECT IDENTIFIER ::= { ipmSlaveOutlet 2 }
+-- ===========================================================================
+--
+-- ipmOutletStatus
+--
+-- Outlet Status Group
+--
+-- ===========================================================================
+-- ==========================================
+-- Outlet Current
+-- ==========================================
+
+ipmSlaveDeviceOutletCurrentTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IpmSlaveDeviceOutletCurrentEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of outlet on this device."
+ ::= { ipmSlaveOutletStatus 1}
+
+ipmSlaveDeviceOutletCurrentEntry OBJECT-TYPE
+ SYNTAX IpmSlaveDeviceOutletCurrentEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The outlet number of device."
+ INDEX { slaveOutletCurrentIndex}
+ ::= { ipmSlaveDeviceOutletCurrentTable 1 }
+
+IpmSlaveDeviceOutletCurrentEntry ::=
+ SEQUENCE {
+ slaveOutletCurrentIndex
+ INTEGER,
+ slaveOutletCurrent01
+ INTEGER,
+ slaveOutletCurrent02
+ INTEGER,
+ slaveOutletCurrent03
+ INTEGER,
+ slaveOutletCurrent04
+ INTEGER,
+ slaveOutletCurrent05
+ INTEGER,
+ slaveOutletCurrent06
+ INTEGER,
+ slaveOutletCurrent07
+ INTEGER,
+ slaveOutletCurrent08
+ INTEGER,
+ slaveOutletCurrent09
+ INTEGER,
+ slaveOutletCurrent10
+ INTEGER,
+ slaveOutletCurrent11
+ INTEGER,
+ slaveOutletCurrent12
+ INTEGER
+ }
+
+slaveOutletCurrentIndex OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to a access outlet configuration table."
+ ::= { ipmSlaveDeviceOutletCurrentEntry 1 }
+
+slaveOutletCurrent01 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The outlet A Current in 0.001 Amp."
+ ::= { ipmSlaveDeviceOutletCurrentEntry 2 }
+
+slaveOutletCurrent02 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The outlet B Current in 0.001 Amp."
+ ::= { ipmSlaveDeviceOutletCurrentEntry 3 }
+
+slaveOutletCurrent03 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The outlet C Current in 0.001 Amp."
+ ::= { ipmSlaveDeviceOutletCurrentEntry 4 }
+
+slaveOutletCurrent04 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The outlet D Current in 0.001 Amp."
+ ::= { ipmSlaveDeviceOutletCurrentEntry 5 }
+
+slaveOutletCurrent05 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The outlet E Current in 0.001 Amp."
+ ::= { ipmSlaveDeviceOutletCurrentEntry 6 }
+
+slaveOutletCurrent06 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The outlet F Current in 0.001 Amp."
+ ::= { ipmSlaveDeviceOutletCurrentEntry 7 }
+
+slaveOutletCurrent07 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The outlet G Current in 0.001 Amp."
+ ::= { ipmSlaveDeviceOutletCurrentEntry 8 }
+
+slaveOutletCurrent08 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The outlet H Current in 0.001 Amp."
+ ::= { ipmSlaveDeviceOutletCurrentEntry 9 }
+
+slaveOutletCurrent09 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The outlet I Current in 0.001 Amp."
+ ::= { ipmSlaveDeviceOutletCurrentEntry 10 }
+
+slaveOutletCurrent10 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The outlet J Current in 0.001 Amp."
+ ::= { ipmSlaveDeviceOutletCurrentEntry 11 }
+
+
+slaveOutletCurrent11 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The outlet K Current in 0.001 Amp."
+ ::= { ipmSlaveDeviceOutletCurrentEntry 12 }
+
+slaveOutletCurrent12 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The outlet L Current in 0.001 Amp."
+ ::= { ipmSlaveDeviceOutletCurrentEntry 13 }
+
+-- ==========================================
+-- Outlet W/H
+-- ==========================================
+
+ipmSlaveDeviceOutletWattTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IpmSlaveDeviceOutletWattEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of outlet on this device."
+ ::= { ipmSlaveOutletStatus 2}
+
+ipmSlaveDeviceOutletWattEntry OBJECT-TYPE
+ SYNTAX IpmSlaveDeviceOutletWattEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The outlet number of device."
+ INDEX { slaveOutletWattIndex}
+ ::= { ipmSlaveDeviceOutletWattTable 1 }
+
+IpmSlaveDeviceOutletWattEntry ::=
+ SEQUENCE {
+ slaveOutletWattIndex
+ INTEGER,
+ slaveOutletWatt01
+ INTEGER,
+ slaveOutletWatt02
+ INTEGER,
+ slaveOutletWatt03
+ INTEGER,
+ slaveOutletWatt04
+ INTEGER,
+ slaveOutletWatt05
+ INTEGER,
+ slaveOutletWatt06
+ INTEGER,
+ slaveOutletWatt07
+ INTEGER,
+ slaveOutletWatt08
+ INTEGER,
+ slaveOutletWatt09
+ INTEGER,
+ slaveOutletWatt10
+ INTEGER,
+ slaveOutletWatt11
+ INTEGER,
+ slaveOutletWatt12
+ INTEGER
+ }
+
+slaveOutletWattIndex OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to a access outlet configuration table."
+ ::= { ipmSlaveDeviceOutletWattEntry 1 }
+
+slaveOutletWatt01 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The outlet A Watt in 0.1 W/H."
+ ::= { ipmSlaveDeviceOutletWattEntry 2 }
+
+slaveOutletWatt02 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The outlet B Watt in 0.1 W/H."
+ ::= { ipmSlaveDeviceOutletWattEntry 3 }
+
+slaveOutletWatt03 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The outlet C Watt in 0.1 W/H."
+ ::= { ipmSlaveDeviceOutletWattEntry 4 }
+
+slaveOutletWatt04 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The outlet D Watt in 0.1 W/H."
+ ::= { ipmSlaveDeviceOutletWattEntry 5 }
+
+slaveOutletWatt05 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The outlet E Watt in 0.1 W/H."
+ ::= { ipmSlaveDeviceOutletWattEntry 6 }
+
+slaveOutletWatt06 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The outlet F Watt in 0.1 W/H."
+ ::= { ipmSlaveDeviceOutletWattEntry 7 }
+
+slaveOutletWatt07 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The outlet G Watt in 0.1 W/H."
+ ::= { ipmSlaveDeviceOutletWattEntry 8 }
+
+slaveOutletWatt08 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The outlet H Watt in 0.1 W/H."
+ ::= { ipmSlaveDeviceOutletWattEntry 9 }
+
+slaveOutletWatt09 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The outlet I Watt in 0.1 W/H."
+ ::= { ipmSlaveDeviceOutletWattEntry 10 }
+
+slaveOutletWatt10 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The outlet J Watt in 0.1 W/H."
+ ::= { ipmSlaveDeviceOutletWattEntry 11 }
+
+
+slaveOutletWatt11 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The outlet K Watt in 0.1 W/H."
+ ::= { ipmSlaveDeviceOutletWattEntry 12 }
+
+slaveOutletWatt12 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The outlet L Watt in 0.1 W/H."
+ ::= { ipmSlaveDeviceOutletWattEntry 13 }
+
+-- ==========================================
+-- Outlet W/H
+-- ==========================================
+
+ipmSlaveDeviceOutletKwattTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IpmSlaveDeviceOutletKwattEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of outlet on this device."
+ ::= { ipmSlaveOutletStatus 3}
+
+ipmSlaveDeviceOutletKwattEntry OBJECT-TYPE
+ SYNTAX IpmSlaveDeviceOutletKwattEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The outlet number of device."
+ INDEX { slaveOutletKwattIndex}
+ ::= { ipmSlaveDeviceOutletKwattTable 1 }
+
+IpmSlaveDeviceOutletKwattEntry ::=
+ SEQUENCE {
+ slaveOutletKwattIndex
+ INTEGER,
+ slaveOutletKwatt01
+ INTEGER,
+ slaveOutletKwatt02
+ INTEGER,
+ slaveOutletKwatt03
+ INTEGER,
+ slaveOutletKwatt04
+ INTEGER,
+ slaveOutletKwatt05
+ INTEGER,
+ slaveOutletKwatt06
+ INTEGER,
+ slaveOutletKwatt07
+ INTEGER,
+ slaveOutletKwatt08
+ INTEGER,
+ slaveOutletKwatt09
+ INTEGER,
+ slaveOutletKwatt10
+ INTEGER,
+ slaveOutletKwatt11
+ INTEGER,
+ slaveOutletKwatt12
+ INTEGER
+ }
+
+slaveOutletKwattIndex OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to a access outlet configuration table."
+ ::= { ipmSlaveDeviceOutletKwattEntry 1 }
+
+slaveOutletKwatt01 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The outlet A Kwatt in 0.001 KW/H."
+ ::= { ipmSlaveDeviceOutletKwattEntry 2 }
+
+slaveOutletKwatt02 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The outlet B Kwatt in 0.001 KW/H."
+ ::= { ipmSlaveDeviceOutletKwattEntry 3 }
+
+slaveOutletKwatt03 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The outlet C Kwatt in 0.001 KW/H."
+ ::= { ipmSlaveDeviceOutletKwattEntry 4 }
+
+slaveOutletKwatt04 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The outlet D Kwatt in 0.001 KW/H."
+ ::= { ipmSlaveDeviceOutletKwattEntry 5 }
+
+slaveOutletKwatt05 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The outlet E Kwatt in 0.001 KW/H."
+ ::= { ipmSlaveDeviceOutletKwattEntry 6 }
+
+slaveOutletKwatt06 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The outlet F Kwatt in 0.001 KW/H."
+ ::= { ipmSlaveDeviceOutletKwattEntry 7 }
+
+slaveOutletKwatt07 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The outlet G Kwatt in 0.001 KW/H."
+ ::= { ipmSlaveDeviceOutletKwattEntry 8 }
+
+slaveOutletKwatt08 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The outlet H Kwatt in 0.001 KW/H."
+ ::= { ipmSlaveDeviceOutletKwattEntry 9 }
+
+slaveOutletKwatt09 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The outlet I Kwatt in 0.001 KW/H."
+ ::= { ipmSlaveDeviceOutletKwattEntry 10 }
+
+slaveOutletKwatt10 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The outlet J Kwatt in 0.001 KW/H."
+ ::= { ipmSlaveDeviceOutletKwattEntry 11 }
+
+
+slaveOutletKwatt11 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The outlet K Kwatt in 0.001 KW/H."
+ ::= { ipmSlaveDeviceOutletKwattEntry 12 }
+
+slaveOutletKwatt12 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The outlet L Kwatt in 0.001 KW/H."
+ ::= { ipmSlaveDeviceOutletKwattEntry 13 }
+
+
+ipmSlaveOutletAction OBJECT IDENTIFIER ::= { ipmSlaveOutlet 3 }
+-- ===========================================================================
+--
+-- ipmOutletStatus
+--
+-- Outlet Action Group
+--
+-- ===========================================================================
+
+ipmSlaveDeviceOutletActionTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IpmSlaveDeviceOutletActionEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of outlet on this device."
+ ::= { ipmSlaveOutletAction 1}
+
+ipmSlaveDeviceOutletActionEntry OBJECT-TYPE
+ SYNTAX IpmSlaveDeviceOutletActionEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The outlet number of device."
+ INDEX { slaveOutletActionIndex}
+ ::= { ipmSlaveDeviceOutletActionTable 1 }
+
+IpmSlaveDeviceOutletActionEntry ::=
+ SEQUENCE {
+ slaveOutletActionIndex
+ INTEGER,
+ slaveOutletAction01
+ INTEGER,
+ slaveOutletAction02
+ INTEGER,
+ slaveOutletAction03
+ INTEGER,
+ slaveOutletAction04
+ INTEGER,
+ slaveOutletAction05
+ INTEGER,
+ slaveOutletAction06
+ INTEGER,
+ slaveOutletAction07
+ INTEGER,
+ slaveOutletAction08
+ INTEGER,
+ slaveOutletAction09
+ INTEGER,
+ slaveOutletAction10
+ INTEGER,
+ slaveOutletAction11
+ INTEGER,
+ slaveOutletAction12
+ INTEGER
+ }
+
+slaveOutletActionIndex OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to a access outlet configuration table."
+ ::= { ipmSlaveDeviceOutletActionEntry 1 }
+
+slaveOutletAction01 OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(1),
+ cancelAction(2),
+ onImmediately(3),
+ offImmediately(4),
+ cycleImmediately(5),
+ onByActionTimer(6),
+ offByActionTimer(7),
+ cycleByActionTimer(8),
+ onThenOffByActionTimers(9),
+ offThenOnByActionTimers(10)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Set to control the outlet perform action as requested."
+ ::= { ipmSlaveDeviceOutletActionEntry 2 }
+
+slaveOutletAction02 OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(1),
+ cancelAction(2),
+ onImmediately(3),
+ offImmediately(4),
+ cycleImmediately(5),
+ onByActionTimer(6),
+ offByActionTimer(7),
+ cycleByActionTimer(8),
+ onThenOffByActionTimers(9),
+ offThenOnByActionTimers(10)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Set to control the outlet perform action as requested."
+ ::= { ipmSlaveDeviceOutletActionEntry 3 }
+
+slaveOutletAction03 OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(1),
+ cancelAction(2),
+ onImmediately(3),
+ offImmediately(4),
+ cycleImmediately(5),
+ onByActionTimer(6),
+ offByActionTimer(7),
+ cycleByActionTimer(8),
+ onThenOffByActionTimers(9),
+ offThenOnByActionTimers(10)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Set to control the outlet perform action as requested."
+ ::= { ipmSlaveDeviceOutletActionEntry 4 }
+
+slaveOutletAction04 OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(1),
+ cancelAction(2),
+ onImmediately(3),
+ offImmediately(4),
+ cycleImmediately(5),
+ onByActionTimer(6),
+ offByActionTimer(7),
+ cycleByActionTimer(8),
+ onThenOffByActionTimers(9),
+ offThenOnByActionTimers(10)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Set to control the outlet perform action as requested."
+ ::= { ipmSlaveDeviceOutletActionEntry 5 }
+
+slaveOutletAction05 OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(1),
+ cancelAction(2),
+ onImmediately(3),
+ offImmediately(4),
+ cycleImmediately(5),
+ onByActionTimer(6),
+ offByActionTimer(7),
+ cycleByActionTimer(8),
+ onThenOffByActionTimers(9),
+ offThenOnByActionTimers(10)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Set to control the outlet perform action as requested."
+ ::= { ipmSlaveDeviceOutletActionEntry 6 }
+
+slaveOutletAction06 OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(1),
+ cancelAction(2),
+ onImmediately(3),
+ offImmediately(4),
+ cycleImmediately(5),
+ onByActionTimer(6),
+ offByActionTimer(7),
+ cycleByActionTimer(8),
+ onThenOffByActionTimers(9),
+ offThenOnByActionTimers(10)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Set to control the outlet perform action as requested."
+ ::= { ipmSlaveDeviceOutletActionEntry 7 }
+
+slaveOutletAction07 OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(1),
+ cancelAction(2),
+ onImmediately(3),
+ offImmediately(4),
+ cycleImmediately(5),
+ onByActionTimer(6),
+ offByActionTimer(7),
+ cycleByActionTimer(8),
+ onThenOffByActionTimers(9),
+ offThenOnByActionTimers(10)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Set to control the outlet perform action as requested."
+ ::= { ipmSlaveDeviceOutletActionEntry 8 }
+
+slaveOutletAction08 OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(1),
+ cancelAction(2),
+ onImmediately(3),
+ offImmediately(4),
+ cycleImmediately(5),
+ onByActionTimer(6),
+ offByActionTimer(7),
+ cycleByActionTimer(8),
+ onThenOffByActionTimers(9),
+ offThenOnByActionTimers(10)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Set to control the outlet perform action as requested."
+ ::= { ipmSlaveDeviceOutletActionEntry 9 }
+
+slaveOutletAction09 OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(1),
+ cancelAction(2),
+ onImmediately(3),
+ offImmediately(4),
+ cycleImmediately(5),
+ onByActionTimer(6),
+ offByActionTimer(7),
+ cycleByActionTimer(8),
+ onThenOffByActionTimers(9),
+ offThenOnByActionTimers(10)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Set to control the outlet perform action as requested."
+ ::= { ipmSlaveDeviceOutletActionEntry 10 }
+
+slaveOutletAction10 OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(1),
+ cancelAction(2),
+ onImmediately(3),
+ offImmediately(4),
+ cycleImmediately(5),
+ onByActionTimer(6),
+ offByActionTimer(7),
+ cycleByActionTimer(8),
+ onThenOffByActionTimers(9),
+ offThenOnByActionTimers(10)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Set to control the outlet perform action as requested."
+ ::= { ipmSlaveDeviceOutletActionEntry 11 }
+
+slaveOutletAction11 OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(1),
+ cancelAction(2),
+ onImmediately(3),
+ offImmediately(4),
+ cycleImmediately(5),
+ onByActionTimer(6),
+ offByActionTimer(7),
+ cycleByActionTimer(8),
+ onThenOffByActionTimers(9),
+ offThenOnByActionTimers(10)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Set to control the outlet perform action as requested."
+ ::= { ipmSlaveDeviceOutletActionEntry 12 }
+
+slaveOutletAction12 OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(1),
+ cancelAction(2),
+ onImmediately(3),
+ offImmediately(4),
+ cycleImmediately(5),
+ onByActionTimer(6),
+ offByActionTimer(7),
+ cycleByActionTimer(8),
+ onThenOffByActionTimers(9),
+ offThenOnByActionTimers(10)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Set to control the outlet perform action as requested."
+ ::= { ipmSlaveDeviceOutletActionEntry 13 }
+
+ipmEnvEmd OBJECT IDENTIFIER ::= { ipmEnv 1 }
+-- ===========================================================================
+--
+-- ipmEnvEmd
+--
+-- Environmental Monitor Device Group
+--
+-- ===========================================================================
+
+ipmEnvEmdStatus OBJECT IDENTIFIER ::= { ipmEnvEmd 1 }
+-- ===========================================================================
+--
+-- ipmEnvEmd
+--
+-- Environmental Monitor Device Status Group
+--
+-- ===========================================================================
+
+ipmEnvEmdStatusEmdType OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(1),
+ disabled(2),
+ eMD-HT(3),
+ eMD-T(4)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "EMD Type."
+ ::= { ipmEnvEmdStatus 1 }
+
+ipmEnvEmdStatusTemperature OBJECT-TYPE
+ SYNTAX INTEGER (1..10000) --
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "EMD Temperature in 0.1 degree C."
+ ::= { ipmEnvEmdStatus 2 }
+
+ipmEnvEmdStatusHumidity OBJECT-TYPE
+ SYNTAX INTEGER (1..10000) --
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "EMD Humidity in 0.1%."
+ ::= { ipmEnvEmdStatus 3 }
+
+ipmEnvEmdStatusAlarm1 OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(1),
+ disabled(2),
+ alarm(3),
+ normal(4)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "EMD Alarm-1 state."
+ ::= { ipmEnvEmdStatus 4 }
+
+ipmEnvEmdStatusAlarm2 OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(1),
+ disabled(2),
+ alarm(3),
+ normal(4)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "EMD Alarm-2 state."
+ ::= { ipmEnvEmdStatus 5 }
+
+ipmEnvEmdConfig OBJECT IDENTIFIER ::= { ipmEnvEmd 2 }
+-- ===========================================================================
+--
+-- ipmEnvEmd
+--
+-- Environmental Monitor Device Configuration Group
+--
+-- ===========================================================================
+ipmEnvEmdConfigEmdPresence OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(1),
+ autoDetect(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Configure the EMD presence by auto-detect or not exist (disabled)."
+ ::= { ipmEnvEmdConfig 1 }
+
+ipmEnvEmdConfigEmdName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..31))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The name of Emd."
+ ::= { ipmEnvEmdConfig 2 }
+
+ipmEnvEmdConfigTemp OBJECT IDENTIFIER ::= { ipmEnvEmdConfig 3 }
+-- ===========================================================================
+--
+-- ipmEnvEmdConfigTemp
+--
+-- Environmental Monitor Device Temperature Configuration Group
+--
+-- ===========================================================================
+ipmEnvEmdConfigTempName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..31))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The name of EMD Temperature sensor."
+ ::= { ipmEnvEmdConfigTemp 1 }
+
+ipmEnvEmdConfigTempHighSetPoint OBJECT-TYPE
+ SYNTAX INTEGER (5..65) --
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "EMD Temperature set point high, alarm will active when temperature
+ over this value, in degree C."
+ ::= { ipmEnvEmdConfigTemp 2 }
+
+ipmEnvEmdConfigTempHighStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ enabled(1),
+ disabled(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Enabled/disabled the high setpoint be applied or not"
+ ::= { ipmEnvEmdConfigTemp 3 }
+
+ipmEnvEmdConfigTempLowSetPoint OBJECT-TYPE
+ SYNTAX INTEGER (5..65) --
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "EMD Temperature set point high, alarm will active when temperature
+ under this value, in degree C."
+ ::= { ipmEnvEmdConfigTemp 4 }
+
+ipmEnvEmdConfigTempLowStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ enabled(1),
+ disabled(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Enabled/disabled the low setpoint be applied or not"
+ ::= { ipmEnvEmdConfigTemp 5 }
+
+ipmEnvEmdConfigTempOffset OBJECT-TYPE
+ SYNTAX INTEGER {
+ t0p0(1),
+ t0p5(2),
+ t1p0(3),
+ t1p5(4),
+ t2p0(5),
+ t2p5(6),
+ t3p0(7),
+ t-0p5(8),
+ t-1p0(9),
+ t-1p5(10),
+ t-2p0(11),
+ t-2p5(12),
+ t-3p0(13)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Offset of temperature in degree C to adjust EMD temperature measurement."
+ ::= { ipmEnvEmdConfigTemp 6 }
+
+ipmEnvEmdConfigHumi OBJECT IDENTIFIER ::= { ipmEnvEmdConfig 4 }
+-- ===========================================================================
+--
+-- ipmEnvEmdConfigHumi
+--
+-- Environmental Monitor Device Humidity Configuration Group
+--
+-- ===========================================================================
+ipmEnvEmdConfigHumiName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..31))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The name of EMD Humidity."
+ ::= { ipmEnvEmdConfigHumi 1 }
+
+ipmEnvEmdConfigHumiHighSetPoint OBJECT-TYPE
+ SYNTAX INTEGER (5..95) --
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "EMD humidity set point high, alarm will active when humidity
+ over this value, in %."
+ ::= { ipmEnvEmdConfigHumi 2 }
+
+ipmEnvEmdConfigHumiHighStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ enabled(1),
+ disabled(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Enabled/disabled the high setpoint be applied or not"
+ ::= { ipmEnvEmdConfigHumi 3 }
+
+ipmEnvEmdConfigHumiLowSetPoint OBJECT-TYPE
+ SYNTAX INTEGER (5..95) --
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "EMD humidity set point low, alarm will active when humidity
+ under this value, in %."
+ ::= { ipmEnvEmdConfigHumi 4 }
+
+ipmEnvEmdConfigHumiLowStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ enabled(1),
+ disabled(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Enabled/disabled the high setpoint be applied or not"
+ ::= { ipmEnvEmdConfigHumi 5 }
+
+ipmEnvEmdConfigHumiOffset OBJECT-TYPE
+ SYNTAX INTEGER {
+ h0p0(1),
+ h1p0(2),
+ h2p0(3),
+ h3p0(4),
+ h4p0(5),
+ h5p0(6),
+ h6p0(7),
+ h-1p0(8),
+ h-2p0(9),
+ h-3p0(10),
+ h-4p0(11),
+ h-5p0(12),
+ h-6p0(13)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Emd Hum Offset;"
+ ::= { ipmEnvEmdConfigHumi 6 }
+
+ipmEnvEmdConfigAlarm1 OBJECT IDENTIFIER ::= { ipmEnvEmdConfig 5 }
+-- ===========================================================================
+--
+-- ipmEnvEmdConfigAlarm1
+--
+-- Environmental Monitor Device Alarm-1 Configuration Group
+--
+-- ===========================================================================
+ipmEnvEmdConfigAlarm1Name OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..31))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The name of EMD Alarm-1."
+ ::= { ipmEnvEmdConfigAlarm1 1 }
+
+ipmEnvEmdConfigAlarm1Type OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(1),
+ normalOpen(2),
+ normalClose(3)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "EMD Alarm-1 type"
+ ::= { ipmEnvEmdConfigAlarm1 2 }
+
+ipmEnvEmdConfigAlarm2 OBJECT IDENTIFIER ::= { ipmEnvEmdConfig 6 }
+-- ===========================================================================
+--
+-- ipmEnvEmdConfigAlarm2
+--
+-- Environmental Monitor Device Alarm-2 Configuration Group
+--
+-- ===========================================================================
+ipmEnvEmdConfigAlarm2Name OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..31))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The name of EMD Alarm-2."
+ ::= { ipmEnvEmdConfigAlarm2 1 }
+
+ipmEnvEmdConfigAlarm2Type OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(1),
+ normalOpen(2),
+ normalClose(3)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "EMD Alarm-2 type"
+ ::= { ipmEnvEmdConfigAlarm2 2 }
+
+
+-- ===========================================================================
+-- ipmTraps
+--
+-- iPoManII Trap group
+-- ===========================================================================
+
+ -- This section defines the well-known notifications sent by
+ -- iPoManII agents.
+
+ipmInletVoltageTooHigh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ VARIABLES {
+ inletConfigIndex,
+ inletStatusVoltage,
+ inletConfigVoltageHigh,
+ inletConfigDesc
+ }
+ DESCRIPTION
+ "CRITICAL: The input voltage over high threshold."
+ ::= 1
+
+ipmInletVoltageNotTooHigh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ VARIABLES {
+ inletConfigIndex,
+ inletStatusVoltage,
+ inletConfigVoltageHigh,
+ inletConfigDesc
+ }
+ DESCRIPTION
+ "WARNING: The input voltage return from over high threshold."
+ ::= 2
+
+ipmInletVoltageTooLow TRAP-TYPE
+ ENTERPRISE ipmTraps
+ VARIABLES {
+ inletConfigIndex,
+ inletStatusVoltage,
+ inletConfigVoltageLow,
+ inletConfigDesc
+ }
+ DESCRIPTION
+ "CRITICAL: The input voltage under low threshold."
+ ::= 3
+
+ipmInletVoltageNotTooLow TRAP-TYPE
+ ENTERPRISE ipmTraps
+ VARIABLES {
+ inletConfigIndex,
+ inletStatusVoltage,
+ inletConfigVoltageLow,
+ inletConfigDesc
+ }
+ DESCRIPTION
+ "WARNING: The input voltage return from under low threshold."
+ ::= 4
+
+ipmInletCurrentTooHigh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ VARIABLES {
+ inletConfigIndex,
+ inletStatusCurrent,
+ inletConfigCurrentHigh,
+ inletConfigDesc
+ }
+ DESCRIPTION
+ "CRITICAL: The input current over high threshold."
+ ::= 5
+
+ipmInletCurrentNotTooHigh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ VARIABLES {
+ inletConfigIndex,
+ inletStatusCurrent,
+ inletConfigCurrentHigh,
+ inletConfigDesc
+ }
+ DESCRIPTION
+ "WARNING: The input current return from over high threshold."
+ ::= 6
+
+ipmInletFrequencyTooHigh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ VARIABLES {
+ inletConfigIndex,
+ inletStatusFrequency,
+ inletConfigFrequencyHigh,
+ inletConfigDesc
+ }
+ DESCRIPTION
+ "CRITICAL: The input frequency over high threshold."
+ ::= 7
+
+ipmInletFrequencyNotTooHigh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ VARIABLES {
+ inletConfigIndex,
+ inletStatusFrequency,
+ inletConfigFrequencyHigh,
+ inletConfigDesc
+ }
+ DESCRIPTION
+ "WARNING: The input frequency return from over high threshold."
+ ::= 8
+
+ipmInletFrequencyTooLow TRAP-TYPE
+ ENTERPRISE ipmTraps
+ VARIABLES {
+ inletConfigIndex,
+ inletStatusFrequency,
+ inletConfigFrequencyLow,
+ inletConfigDesc
+ }
+ DESCRIPTION
+ "CRITICAL: The input frequency under low threshold."
+ ::= 9
+
+ipmInletFrequencyNotTooLow TRAP-TYPE
+ ENTERPRISE ipmTraps
+ VARIABLES {
+ inletConfigIndex,
+ inletStatusFrequency,
+ inletConfigFrequencyLow,
+ inletConfigDesc
+ }
+ DESCRIPTION
+ "WARNING: The input frequency return from under low threshold."
+ ::= 10
+
+ipmOutletCurrentTooHigh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ VARIABLES {
+ outletConfigIndex,
+ outletStatusCurrent,
+ outletConfigCurrentHigh,
+ outletConfigDesc
+ }
+ DESCRIPTION
+ "CRITICAL: The output current of outlet over high threshold."
+ ::= 11
+
+ipmOutletCurrentNotTooHigh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ VARIABLES {
+ outletConfigIndex,
+ outletStatusCurrent,
+ outletConfigCurrentHigh,
+ outletConfigDesc
+ }
+ DESCRIPTION
+ "WARNING: The output current of outlet return from over high threshold."
+ ::= 12
+
+ipmOutletStateChanged TRAP-TYPE
+ ENTERPRISE ipmTraps
+ VARIABLES {
+ outletConfigIndex,
+ outletStatusStatus,
+ outletConfigDesc
+ }
+ DESCRIPTION
+ "INFORMATION: The outlet state had changed from on to off, or from off to on."
+ ::= 13
+
+ipmEmdTemperatureNotHigh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ VARIABLES {
+ ipmEnvEmdStatusTemperature,
+ ipmEnvEmdConfigTempHighSetPoint,
+ ipmEnvEmdConfigTempName
+ }
+ DESCRIPTION
+ "INFORMATION: emd Temperature Not High."
+ ::= 14
+
+ipmEmdTemperatureTooHigh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ VARIABLES {
+ ipmEnvEmdStatusTemperature,
+ ipmEnvEmdConfigTempHighSetPoint,
+ ipmEnvEmdConfigTempName
+ }
+ DESCRIPTION
+ "WARNING: emd Temperature Too High."
+ ::= 15
+
+ipmEmdTemperatureNotLow TRAP-TYPE
+ ENTERPRISE ipmTraps
+ VARIABLES {
+ ipmEnvEmdStatusTemperature,
+ ipmEnvEmdConfigTempLowSetPoint,
+ ipmEnvEmdConfigTempName
+ }
+ DESCRIPTION
+ "INFORMATION: emd Temperature Not Low."
+ ::= 16
+
+ipmEmdTemperatureTooLow TRAP-TYPE
+ ENTERPRISE ipmTraps
+ VARIABLES {
+ ipmEnvEmdStatusTemperature,
+ ipmEnvEmdConfigTempLowSetPoint,
+ ipmEnvEmdConfigTempName
+ }
+ DESCRIPTION
+ "WARNING: emd Temperature Too Low."
+ ::= 17
+
+ipmEmdHumidityNotHigh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ VARIABLES {
+ ipmEnvEmdStatusHumidity,
+ ipmEnvEmdConfigHumiHighSetPoint,
+ ipmEnvEmdConfigHumiName
+ }
+ DESCRIPTION
+ "INFORMATION: emd Humidity Not High."
+ ::= 18
+
+ipmEmdHumidityTooHigh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ VARIABLES {
+ ipmEnvEmdStatusHumidity,
+ ipmEnvEmdConfigHumiHighSetPoint,
+ ipmEnvEmdConfigHumiName
+ }
+ DESCRIPTION
+ "WARNING: emd Humidity Too High."
+ ::= 19
+
+ipmEmdHumidityNotLow TRAP-TYPE
+ ENTERPRISE ipmTraps
+ VARIABLES {
+ ipmEnvEmdStatusHumidity,
+ ipmEnvEmdConfigHumiLowSetPoint,
+ ipmEnvEmdConfigHumiName
+ }
+ DESCRIPTION
+ "INFORMATION: emd Humidity Not Low."
+ ::= 20
+
+ipmEmdHumidityTooLow TRAP-TYPE
+ ENTERPRISE ipmTraps
+ VARIABLES {
+ ipmEnvEmdStatusHumidity,
+ ipmEnvEmdConfigHumiLowSetPoint,
+ ipmEnvEmdConfigHumiName
+ }
+ DESCRIPTION
+ "WARNING: emd Humidity Too Low."
+ ::= 21
+
+ipmEmdAlarm1Normal TRAP-TYPE
+ ENTERPRISE ipmTraps
+ VARIABLES {
+ ipmEnvEmdConfigAlarm1Type,
+ ipmEnvEmdConfigAlarm1Name
+ }
+ DESCRIPTION
+ "INFORMATION: emd Alarm1 Normal."
+ ::= 22
+
+ipmEmdAlarm1Active TRAP-TYPE
+ ENTERPRISE ipmTraps
+ VARIABLES {
+ ipmEnvEmdConfigAlarm1Type,
+ ipmEnvEmdConfigAlarm1Name
+ }
+ DESCRIPTION
+ "WARNING: emd Alarm1 Active."
+ ::= 23
+
+ipmEmdAlarm2Normal TRAP-TYPE
+ ENTERPRISE ipmTraps
+ VARIABLES {
+ ipmEnvEmdConfigAlarm2Type,
+ ipmEnvEmdConfigAlarm2Name
+ }
+ DESCRIPTION
+ "INFORMATION: emd Alarm2 Normal."
+ ::= 24
+
+ipmEmdAlarm2Active TRAP-TYPE
+ ENTERPRISE ipmTraps
+ VARIABLES {
+ ipmEnvEmdConfigAlarm2Type,
+ ipmEnvEmdConfigAlarm2Name
+ }
+ DESCRIPTION
+ "WARNING: emd Alarm2 Active."
+ ::= 25
+
+ipmSlave01Inlet01OverHigh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "CRITICAL: The Slave01 input01 voltage over high threshold."
+ ::= 26
+
+ipmSlave01Inlet01NotOverHigh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "CRITICAL: The Slave01 input01 voltage Not over high threshold."
+ ::= 27
+
+ipmSlave01Inlet02OverHigh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "CRITICAL: The Slave01 input02 voltage over high threshold."
+ ::= 28
+
+ipmSlave01Inlet02NotOverHigh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "CRITICAL: The Slave01 input02 voltage Not over high threshold."
+ ::= 29
+
+ipmSlave01Inlet01UnderLow TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "CRITICAL: The Slave01 input01 voltage under low threshold."
+ ::= 30
+
+ipmSlave01Inlet01NotUnderLow TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "CRITICAL: The Slave01 input01 voltage Not under low threshold."
+ ::= 31
+
+ipmSlave01Inlet02UnderLow TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "CRITICAL: The Slave01 input02 voltage under low threshold."
+ ::= 32
+
+ipmSlave01Inlet02NotUnderLow TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "CRITICAL: The Slave01 input02 voltage Not under low threshold."
+ ::= 33
+
+ipmSlave01Inlet01CurrentOverTh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "CRITICAL: The Slave01 input01 current over high threshold."
+ ::= 34
+
+ipmSlave01Inlet01NotCurrentOverTh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "CRITICAL: The Slave01 input01 current not over high threshold."
+ ::= 35
+
+ipmSlave01Inlet02CurrentOverTh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "CRITICAL: The Slave01 input02 current over high threshold."
+ ::= 36
+
+ipmSlave01Inlet02NotCurrentOverTh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "CRITICAL: The Slave01 input02 current not over high threshold."
+ ::= 37
+
+ipmSlave01EmdTemperatureNotHigh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "INFORMATION: The Slave01 emd Temperature Not High."
+ ::= 38
+
+ipmSlave01EmdTemperatureTooHigh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "WARNING: The Slave01 emd Temperature Too High."
+ ::= 39
+
+ipmSlave01EmdTemperatureNotLow TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "INFORMATION: The Slave01 emd Temperature Not Low."
+ ::= 40
+
+ipmSlave01EmdTemperatureTooLow TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "WARNING: The Slave01 emd Temperature Too Low."
+ ::= 41
+
+ipmSlave01EmdHumidityNotHigh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "INFORMATION: The Slave01 emd Humidity Not High."
+ ::= 42
+
+ipmSlave01EmdHumidityTooHigh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "WARNING: The Slave01 emd Humidity Too High."
+ ::= 43
+
+ipmSlave01EmdHumidityNotLow TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "INFORMATION: The Slave01 emd Humidity Not Low."
+ ::= 44
+
+ipmSlave01EmdHumidityTooLow TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "WARNING: The Slave01 emd Humidity Too Low."
+ ::= 45
+
+ipmSlave01EmdAlarm1Normal TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "INFORMATION: The Slave01 emd Alarm1 Normal."
+ ::= 46
+
+ipmSlave01EmdAlarm1Active TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "WARNING: The Slave01 emd Alarm1 Active."
+ ::= 47
+
+ipmSlave01EmdAlarm2Normal TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "INFORMATION: The Slave01 emd Alarm2 Normal."
+ ::= 48
+
+ipmSlave01EmdAlarm2Active TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "WARNING: The Slave01 emd Alarm2 Active."
+ ::= 49
+
+ipmSlave01OutletCurrentOverTh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "WARNING: The Slave01 Outlet Current over threshold."
+ ::= 50
+
+ipmSlave02Inlet01OverHigh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "CRITICAL: The Slave02 input01 voltage over high threshold."
+ ::= 51
+
+ipmSlave02Inlet01NotOverHigh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "CRITICAL: The Slave02 input01 voltage Not over high threshold."
+ ::= 52
+
+ipmSlave02Inlet02OverHigh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "CRITICAL: The Slave02 input02 voltage over high threshold."
+ ::= 53
+
+ipmSlave02Inlet02NotOverHigh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "CRITICAL: The Slave02 input02 voltage Not over high threshold."
+ ::= 54
+
+ipmSlave02Inlet01UnderLow TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "CRITICAL: The Slave02 input01 voltage under low threshold."
+ ::= 55
+
+ipmSlave02Inlet01NotUnderLow TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "CRITICAL: The Slave02 input01 voltage Not under low threshold."
+ ::= 56
+
+ipmSlave02Inlet02UnderLow TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "CRITICAL: The Slave02 input02 voltage under low threshold."
+ ::= 57
+
+ipmSlave02Inlet02NotUnderLow TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "CRITICAL: The Slave02 input02 voltage Not under low threshold."
+ ::= 58
+
+ipmSlave02Inlet01CurrentOverTh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "CRITICAL: The Slave02 input01 current over high threshold."
+ ::= 59
+
+ipmSlave02Inlet01NotCurrentOverTh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "CRITICAL: The Slave02 input01 current not over high threshold."
+ ::= 60
+
+ipmSlave02Inlet02CurrentOverTh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "CRITICAL: The Slave02 input02 current over high threshold."
+ ::= 61
+
+ipmSlave02Inlet02NotCurrentOverTh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "CRITICAL: The Slave02 input02 current not over high threshold."
+ ::= 62
+
+ipmSlave02EmdTemperatureNotHigh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "INFORMATION: The Slave02 emd Temperature Not High."
+ ::= 63
+
+ipmSlave02EmdTemperatureTooHigh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "WARNING: The Slave02 emd Temperature Too High."
+ ::= 64
+
+ipmSlave02EmdTemperatureNotLow TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "INFORMATION: The Slave02 emd Temperature Not Low."
+ ::= 65
+
+ipmSlave02EmdTemperatureTooLow TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "WARNING: The Slave02 emd Temperature Too Low."
+ ::= 66
+
+ipmSlave02EmdHumidityNotHigh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "INFORMATION: The Slave02 emd Humidity Not High."
+ ::= 67
+
+ipmSlave02EmdHumidityTooHigh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "WARNING: The Slave02 emd Humidity Too High."
+ ::= 68
+
+ipmSlave02EmdHumidityNotLow TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "INFORMATION: The Slave02 emd Humidity Not Low."
+ ::= 69
+
+ipmSlave02EmdHumidityTooLow TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "WARNING: The Slave02 emd Humidity Too Low."
+ ::= 70
+
+ipmSlave02EmdAlarm1Normal TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "INFORMATION: The Slave02 emd Alarm1 Normal."
+ ::= 71
+
+ipmSlave02EmdAlarm1Active TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "WARNING: The Slave02 emd Alarm1 Active."
+ ::= 72
+
+ipmSlave02EmdAlarm2Normal TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "INFORMATION: The Slave02 emd Alarm2 Normal."
+ ::= 73
+
+ipmSlave02EmdAlarm2Active TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "WARNING: The Slave02 emd Alarm2 Active."
+ ::= 74
+
+ipmSlave02OutletCurrentOverTh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "WARNING: The Slave02 Outlet Current over threshold."
+ ::= 75
+
+ipmSlave03Inlet01OverHigh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "CRITICAL: The Slave03 input01 voltage over high threshold."
+ ::= 76
+
+ipmSlave03Inlet01NotOverHigh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "CRITICAL: The Slave03 input01 voltage Not over high threshold."
+ ::= 77
+
+ipmSlave03Inlet02OverHigh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "CRITICAL: The Slave03 input02 voltage over high threshold."
+ ::= 78
+
+ipmSlave03Inlet02NotOverHigh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "CRITICAL: The Slave03 input02 voltage Not over high threshold."
+ ::= 79
+
+ipmSlave03Inlet01UnderLow TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "CRITICAL: The Slave03 input01 voltage under low threshold."
+ ::= 80
+
+ipmSlave03Inlet01NotUnderLow TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "CRITICAL: The Slave03 input01 voltage Not under low threshold."
+ ::= 81
+
+ipmSlave03Inlet02UnderLow TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "CRITICAL: The Slave03 input02 voltage under low threshold."
+ ::= 82
+
+ipmSlave03Inlet02NotUnderLow TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "CRITICAL: The Slave03 input02 voltage Not under low threshold."
+ ::= 83
+
+ipmSlave03Inlet01CurrentOverTh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "CRITICAL: The Slave03 input01 current over high threshold."
+ ::= 84
+
+ipmSlave03Inlet01NotCurrentOverTh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "CRITICAL: The Slave03 input01 current not over high threshold."
+ ::= 85
+
+ipmSlave03Inlet02CurrentOverTh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "CRITICAL: The Slave03 input02 current over high threshold."
+ ::= 86
+
+ipmSlave03Inlet02NotCurrentOverTh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "CRITICAL: The Slave03 input02 current not over high threshold."
+ ::= 87
+
+ipmSlave03EmdTemperatureNotHigh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "INFORMATION: The Slave03 emd Temperature Not High."
+ ::= 88
+
+ipmSlave03EmdTemperatureTooHigh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "WARNING: The Slave03 emd Temperature Too High."
+ ::= 89
+
+ipmSlave03EmdTemperatureNotLow TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "INFORMATION: The Slave03 emd Temperature Not Low."
+ ::= 90
+
+ipmSlave03EmdTemperatureTooLow TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "WARNING: The Slave03 emd Temperature Too Low."
+ ::= 91
+
+ipmSlave03EmdHumidityNotHigh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "INFORMATION: The Slave03 emd Humidity Not High."
+ ::= 92
+
+ipmSlave03EmdHumidityTooHigh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "WARNING: The Slave03 emd Humidity Too High."
+ ::= 93
+
+ipmSlave03EmdHumidityNotLow TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "INFORMATION: The Slave03 emd Humidity Not Low."
+ ::= 94
+
+ipmSlave03EmdHumidityTooLow TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "WARNING: The Slave03 emd Humidity Too Low."
+ ::= 95
+
+ipmSlave03EmdAlarm1Normal TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "INFORMATION: The Slave03 emd Alarm1 Normal."
+ ::= 96
+
+ipmSlave03EmdAlarm1Active TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "WARNING: The Slave03 emd Alarm1 Active."
+ ::= 97
+
+ipmSlave03EmdAlarm2Normal TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "INFORMATION: The Slave03 emd Alarm2 Normal."
+ ::= 98
+
+ipmSlave03EmdAlarm2Active TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "WARNING: The Slave03 emd Alarm2 Active."
+ ::= 99
+
+ipmSlave03OutletCurrentOverTh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "WARNING: The Slave03 Outlet Current over threshold."
+ ::= 100
+
+ipmSlave04Inlet01OverHigh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "CRITICAL: The Slave04 input01 voltage over high threshold."
+ ::= 101
+
+ipmSlave04Inlet01NotOverHigh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "CRITICAL: The Slave04 input01 voltage Not over high threshold."
+ ::= 102
+
+ipmSlave04Inlet02OverHigh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "CRITICAL: The Slave04 input02 voltage over high threshold."
+ ::= 103
+
+ipmSlave04Inlet02NotOverHigh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "CRITICAL: The Slave04 input02 voltage Not over high threshold."
+ ::= 104
+
+ipmSlave04Inlet01UnderLow TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "CRITICAL: The Slave04 input01 voltage under low threshold."
+ ::= 105
+
+ipmSlave04Inlet01NotUnderLow TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "CRITICAL: The Slave04 input01 voltage Not under low threshold."
+ ::= 106
+
+ipmSlave04Inlet02UnderLow TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "CRITICAL: The Slave04 input02 voltage under low threshold."
+ ::= 107
+
+ipmSlave04Inlet02NotUnderLow TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "CRITICAL: The Slave04 input02 voltage Not under low threshold."
+ ::= 108
+
+ipmSlave04Inlet01CurrentOverTh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "CRITICAL: The Slave04 input01 current over high threshold."
+ ::= 109
+
+ipmSlave04Inlet01NotCurrentOverTh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "CRITICAL: The Slave04 input01 current not over high threshold."
+ ::= 110
+
+ipmSlave04Inlet02CurrentOverTh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "CRITICAL: The Slave04 input02 current over high threshold."
+ ::= 111
+
+ipmSlave04Inlet02NotCurrentOverTh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "CRITICAL: The Slave04 input02 current not over high threshold."
+ ::= 112
+
+ipmSlave04EmdTemperatureNotHigh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "INFORMATION: The Slave04 emd Temperature Not High."
+ ::= 113
+
+ipmSlave04EmdTemperatureTooHigh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "WARNING: The Slave04 emd Temperature Too High."
+ ::= 114
+
+ipmSlave04EmdTemperatureNotLow TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "INFORMATION: The Slave04 emd Temperature Not Low."
+ ::= 115
+
+ipmSlave04EmdTemperatureTooLow TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "WARNING: The Slave04 emd Temperature Too Low."
+ ::= 116
+
+ipmSlave04EmdHumidityNotHigh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "INFORMATION: The Slave04 emd Humidity Not High."
+ ::= 117
+
+ipmSlave04EmdHumidityTooHigh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "WARNING: The Slave04 emd Humidity Too High."
+ ::= 118
+
+ipmSlave04EmdHumidityNotLow TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "INFORMATION: The Slave04 emd Humidity Not Low."
+ ::= 119
+
+ipmSlave04EmdHumidityTooLow TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "WARNING: The Slave04 emd Humidity Too Low."
+ ::= 120
+
+ipmSlave04EmdAlarm1Normal TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "INFORMATION: The Slave04 emd Alarm1 Normal."
+ ::= 121
+
+ipmSlave04EmdAlarm1Active TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "WARNING: The Slave04 emd Alarm1 Active."
+ ::= 122
+
+ipmSlave04EmdAlarm2Normal TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "INFORMATION: The Slave04 emd Alarm2 Normal."
+ ::= 123
+
+ipmSlave04EmdAlarm2Active TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "WARNING: The Slave04 emd Alarm2 Active."
+ ::= 124
+
+ipmSlave04OutletCurrentOverTh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "WARNING: The Slave04 Outlet Current over threshold."
+ ::= 125
+
+ipmSlave05Inlet01OverHigh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "CRITICAL: The Slave05 input01 voltage over high threshold."
+ ::= 126
+
+ipmSlave05Inlet01NotOverHigh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "CRITICAL: The Slave05 input01 voltage Not over high threshold."
+ ::= 127
+
+ipmSlave05Inlet02OverHigh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "CRITICAL: The Slave05 input02 voltage over high threshold."
+ ::= 128
+
+ipmSlave05Inlet02NotOverHigh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "CRITICAL: The Slave05 input02 voltage Not over high threshold."
+ ::= 129
+
+ipmSlave05Inlet01UnderLow TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "CRITICAL: The Slave05 input01 voltage under low threshold."
+ ::= 130
+
+ipmSlave05Inlet01NotUnderLow TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "CRITICAL: The Slave05 input01 voltage Not under low threshold."
+ ::= 131
+
+ipmSlave05Inlet02UnderLow TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "CRITICAL: The Slave05 input02 voltage under low threshold."
+ ::= 132
+
+ipmSlave05Inlet02NotUnderLow TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "CRITICAL: The Slave05 input02 voltage Not under low threshold."
+ ::= 133
+
+ipmSlave05Inlet01CurrentOverTh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "CRITICAL: The Slave05 input01 current over high threshold."
+ ::= 134
+
+ipmSlave05Inlet01NotCurrentOverTh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "CRITICAL: The Slave05 input01 current not over high threshold."
+ ::= 135
+
+ipmSlave05Inlet02CurrentOverTh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "CRITICAL: The Slave05 input02 current over high threshold."
+ ::= 136
+
+ipmSlave05Inlet02NotCurrentOverTh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "CRITICAL: The Slave05 input02 current not over high threshold."
+ ::= 137
+
+ipmSlave05EmdTemperatureNotHigh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "INFORMATION: The Slave05 emd Temperature Not High."
+ ::= 138
+
+ipmSlave05EmdTemperatureTooHigh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "WARNING: The Slave05 emd Temperature Too High."
+ ::= 139
+
+ipmSlave05EmdTemperatureNotLow TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "INFORMATION: The Slave05 emd Temperature Not Low."
+ ::= 140
+
+ipmSlave05EmdTemperatureTooLow TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "WARNING: The Slave05 emd Temperature Too Low."
+ ::= 141
+
+ipmSlave05EmdHumidityNotHigh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "INFORMATION: The Slave05 emd Humidity Not High."
+ ::= 142
+
+ipmSlave05EmdHumidityTooHigh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "WARNING: The Slave05 emd Humidity Too High."
+ ::= 143
+
+ipmSlave05EmdHumidityNotLow TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "INFORMATION: The Slave05 emd Humidity Not Low."
+ ::= 144
+
+ipmSlave05EmdHumidityTooLow TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "WARNING: The Slave05 emd Humidity Too Low."
+ ::= 145
+
+ipmSlave05EmdAlarm1Normal TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "INFORMATION: The Slave05 emd Alarm1 Normal."
+ ::= 146
+
+ipmSlave05EmdAlarm1Active TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "WARNING: The Slave05 emd Alarm1 Active."
+ ::= 147
+
+ipmSlave05EmdAlarm2Normal TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "INFORMATION: The Slave05 emd Alarm2 Normal."
+ ::= 148
+
+ipmSlave05EmdAlarm2Active TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "WARNING: The Slave05 emd Alarm2 Active."
+ ::= 149
+
+ipmSlave05OutletCurrentOverTh TRAP-TYPE
+ ENTERPRISE ipmTraps
+ DESCRIPTION
+ "WARNING: The Slave05 Outlet Current over threshold."
+ ::= 150
+
+ END