diff options
| author | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
|---|---|---|
| committer | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
| commit | 98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch) | |
| tree | 9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/juniper/JUNIPER-MIB | |
| download | mibs-main.tar.gz mibs-main.zip | |
Diffstat (limited to 'MIBS/juniper/JUNIPER-MIB')
| -rw-r--r-- | MIBS/juniper/JUNIPER-MIB | 2436 |
1 files changed, 2436 insertions, 0 deletions
diff --git a/MIBS/juniper/JUNIPER-MIB b/MIBS/juniper/JUNIPER-MIB new file mode 100644 index 0000000..a2e99b6 --- /dev/null +++ b/MIBS/juniper/JUNIPER-MIB @@ -0,0 +1,2436 @@ +-- +-- Juniper Enterprise Specific MIB: Chassis MIB +-- +-- Copyright (c) 1998-2015, Juniper Networks, Inc. +-- All rights reserved. +-- +-- The contents of this document are subject to change without notice. +-- + + +JUNIPER-MIB DEFINITIONS ::= BEGIN + +IMPORTS + MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, + Integer32, Gauge32, Counter32 + FROM SNMPv2-SMI + DisplayString, TimeStamp, TimeInterval, TEXTUAL-CONVENTION, DateAndTime + FROM SNMPv2-TC + jnxMibs, jnxChassisTraps, jnxChassisOKTraps + FROM JUNIPER-SMI; + +jnxBoxAnatomy MODULE-IDENTITY + + LAST-UPDATED "201605160000Z" -- May 16, 2016 + ORGANIZATION "Juniper Networks, Inc." + CONTACT-INFO + " Juniper Technical Assistance Center + Juniper Networks, Inc. + 1194 N. Mathilda Avenue + Sunnyvale, CA 94089 + E-mail: support@juniper.net" + + DESCRIPTION + "The MIB modules representing Juniper Networks' + implementation of enterprise specific MIBs + supported by a single SNMP agent." + REVISION "200403230000Z" + DESCRIPTION + "Added chassis identification objects." + REVISION "200406300000Z" -- July 30, 2004 + DESCRIPTION + "Added following new traps for chassis + alarm conditions: jnxFruFailed, jnxFruOffline + and jnxFruOnline." + REVISION "200409170000Z" -- Sep 17, 2004 + DESCRIPTION + "Added new traps for chassis + alarm condition jnxFruCheck." + REVISION "200507180000Z" -- Jul 18, 2005 + DESCRIPTION + "Added new fru type FEB in jnxFruType enumeration." + REVISION "200507190000Z" -- Jul 19, 2005 + DESCRIPTION + "Added new offline reason pfeVersionMismatch + to jnxFruOfflineReason enumeration." + REVISION "200611200000Z" -- Nov 20, 2006 + DESCRIPTION + "Added new offline reason fruFebOffline + to jnxFruOfflineReason enumeration." + REVISION "200807310000Z" -- Jul 31, 2008 + DESCRIPTION + "Added jnxBoxSystemDomainType object." + REVISION "200808010000Z" -- Aug 01, 2008 + DESCRIPTION + "Added new fru type PSD to jnxFruType enumeration and + added jcsX chassis IDs to JnxChassisId enumeration." + REVISION "200812310000Z" -- Dec 31, 2008 + DESCRIPTION + "Added nodeX chassis IDs to JnxChassisId enumeration." + REVISION "200901090000Z" -- Jan 09, 2009 + DESCRIPTION + "Added sfcX and lcc4-lcc15 chassis IDs to JnxChassisId + enumeration." + REVISION "201010220000Z" -- Oct 22, 2010 + DESCRIPTION + "Added load average variables" + REVISION "201109090000Z" -- Sep 09, 2011 + DESCRIPTION + "Added jnxBoxPersonality for MidRangius Boxes + namely MX40/MX10/MX5" + REVISION "201202150000Z" -- Feb 02, 2012 + DESCRIPTION + "Added new offline reason builtinPicBounce to + jnxFruOfflineReason enumeration." + REVISION "201202210000Z" -- Feb 21, 2012 + DESCRIPTION + "Added new jnxFruType: PDU and PSM, + and new traps: jnxFmLinkErr and jnxFmCellDropErr." + REVISION "201208240000Z" -- Aug 24, 2012 + DESCRIPTION + "Added new offline reason fruTypeConfigMismatch to + jnxFruOfflineReason enumeration." + REVISION "201208240000Z" -- Aug 24, 2012 + DESCRIPTION + "Added new offline reason fruTypeConfigMismatch to + jnxFruOfflineReason enumeration." + REVISION "201210120000Z" -- Oct 12, 2012 + DESCRIPTION + "Added new offline reason fruPICOfflineOnEccErrors to + jnxFruOfflineReason enumeration." + REVISION "201211070000Z" -- Nov 07, 2012 + DESCRIPTION + "Added new offline reasons fruFpcIncompatible and + fruFpcFanTrayPEMIncompatible to + jnxFruOfflineReason enumeration." + REVISION "201301070000Z" -- Jan 07, 2013 + DESCRIPTION + "Added new offline reason openflowConfigChange to + jnxFruOfflineReason enumeration." + REVISION "201302280000Z" -- Feb 28, 2013 + DESCRIPTION + "Added new offline reasons fruFpcScbIncompatible to + jnxFruOfflineReason enumeration." + REVISION "201303220000Z" -- Mar 22, 2013 + DESCRIPTION + "Added new offline reason hwError + to jnxFruOfflineReason enumeration." + REVISION "201305220000Z" -- May 22, 2013 + DESCRIPTION + "Added new offline reasons fruReUnresponsive to + jnxFruOfflineReason enumeration." + REVISION "201307170000Z" -- Jul 17, 2013 + DESCRIPTION + "Added new Fabric plane offline/online/check traps + to trap fabric plane offline/online/fault events." + REVISION "201309240000Z" -- Sep 24, 2013 + DESCRIPTION + "Added new offline reason hwError + to jnxFruOfflineReason enumeration." + REVISION "201310150000Z" -- Oct 15, 2013 + DESCRIPTION + "Added new offline reason fruIncompatibleWithPEM, + fruIncompatibleWithSIB, and sibIncompatibleWithOtherSIB + to jnxFruOfflineReason enumeration." + REVISION "201311190000Z" -- Nov 19, 2013 + DESCRIPTION + "Added new offline reason fruPfeErrors to + jnxFruOfflineReason enumeration." + REVISION "201212100000Z" -- Dec 10, 2012 + DESCRIPTION + "Added new OIDs to get control plane memory + allocation (jnxOperatingMemoryCP) + and utilization(jnxOperatingBufferCP) in RE." + + REVISION "201404080000Z" -- Apr 08, 2014 + DESCRIPTION + "Added new offline reason vpnLocalizationRoleChange to + jnxFruOfflineReason enumeration." + + REVISION "201405200000Z" -- May 20, 2014 + DESCRIPTION + "Added MIBs for 1, 5 and 15 min average CPU util" + + REVISION "201407300000Z" -- Jul 30, 2014 + DESCRIPTION + "Added new offline reasons fruFpcFanTrayIncompatible & + fruFpcPEMIncompatible to jnxFruOfflineReason enumeration." + + REVISION "201501140000Z" -- Jan 14, 2015 + DESCRIPTION + "Added new color types for jnxLEDState and jnxLEDStateOrdered." + + REVISION "201412040000Z" -- Dec 04, 2014 + DESCRIPTION + "Added new trap: jnxFmAsicErr." + + REVISION "201504010000Z" -- Apr 1, 2015 + DESCRIPTION + "Added new FRU Power consumption variable." + + REVISION "201504280000Z" -- Apr 28, 2015 + DESCRIPTION + "Added new MIB jnxContentsModel." + + REVISION "201602020000Z" -- Feb 02, 2016 + DESCRIPTION + "Added new offline reason fruFpcHFanTrayIncompatible and + missing entries mixedSwitchFabric, unsupportedFabric, + jamConfigError." + + REVISION "201605160000Z" -- May 16, 2016 + DESCRIPTION + "Added new trap: jnxFmHealthChkErr." + + ::= { jnxMibs 1 } + +-- +-- Textual Conventions +-- + +JnxChassisId ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION "Identifies a specific router chassis." + SYNTAX INTEGER { + unknown (1), + singleChassis (2), + scc (3), + lcc0 (4), + lcc1 (5), + lcc2 (6), + lcc3 (7), + jcs1 (8), + jcs2 (9), + jcs3 (10), + jcs4 (11), + node0 (12), + node1 (13), + sfc0 (14), + sfc1 (15), + sfc2 (16), + sfc3 (17), + sfc4 (18), + lcc4 (19), + lcc5 (20), + lcc6 (21), + lcc7 (22), + lcc8 (23), + lcc9 (24), + lcc10 (25), + lcc11 (26), + lcc12 (27), + lcc13 (28), + lcc14 (29), + lcc15 (30), + member0 (31), + member1 (32), + member2 (33), + member3 (34), + member4 (35), + member5 (36), + member6 (37), + member7 (38), + nodeDevice (39), + interconnectDevice (40), + controlPlaneDevice (41), + directorDevice (42), + gnf1 (43), + gnf2 (44), + gnf3 (45), + gnf4 (46), + gnf5 (47), + gnf6 (48), + gnf7 (49), + gnf8 (50), + gnf9 (51), + gnf10 (52) + } + + + +-- Juniper Box Anatomy MIB +-- + +-- Top level objects + + jnxBoxClass OBJECT-TYPE + SYNTAX OBJECT IDENTIFIER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The class of the box, indicating which product line + the box is about, for example, 'Internet Router'." + ::= { jnxBoxAnatomy 1 } + + jnxBoxDescr OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..255)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The name, model, or detailed description of the box, + indicating which product the box is about, for example + 'M40'." + ::= { jnxBoxAnatomy 2 } + + jnxBoxSerialNo OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..255)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The serial number of this subject, blank if unknown + or unavailable." + ::= { jnxBoxAnatomy 3 } + + jnxBoxRevision OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..255)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The revision of this subject, blank if unknown or + unavailable." + ::= { jnxBoxAnatomy 4 } + + jnxBoxInstalled OBJECT-TYPE + SYNTAX TimeStamp + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The value of sysUpTime when the subject was last + installed, up-and-running. Zero if unknown or + already up-and-running when the agent was up." + ::= { jnxBoxAnatomy 5 } + +-- +-- Box Containers Table +-- + + jnxContainersTable OBJECT-TYPE + SYNTAX SEQUENCE OF JnxContainersEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of containers entries." + ::= { jnxBoxAnatomy 6 } + + jnxContainersEntry OBJECT-TYPE + SYNTAX JnxContainersEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry of containers table." + INDEX { jnxContainersIndex } + ::= { jnxContainersTable 1 } + + JnxContainersEntry ::= SEQUENCE { + jnxContainersIndex Integer32, + jnxContainersView Integer32, + jnxContainersLevel Integer32, + jnxContainersWithin Integer32, + jnxContainersType OBJECT IDENTIFIER, + jnxContainersDescr DisplayString, + jnxContainersCount Integer32 + } + + jnxContainersIndex OBJECT-TYPE + SYNTAX Integer32 (1..'7fffffff'h) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The index for this entry." + ::= { jnxContainersEntry 1 } + + jnxContainersView OBJECT-TYPE + SYNTAX Integer32 (1..63) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The view(s) from which the specific container + appears. + + This variable indicates that the specific container + is embedded and accessible from the corresponding + view(s). + + The value is a bit map represented as a sum. + If multiple bits are set, the specified + container(s) are located and accessible from + that set of views. + + The various values representing the bit positions + and its corresponding views are: + 1 front + 2 rear + 4 top + 8 bottom + 16 leftHandSide + 32 rightHandSide + + Note 1: + LefHandSide and rightHandSide are referred + to based on the view from the front. + + Note 2: + If the specified containers are scattered + around various views, the numbering is according + to the following sequence: + front -> rear -> top -> bottom + -> leftHandSide -> rightHandSide + For each view plane, the numbering sequence is + first from left to right, and then from up to down. + + Note 3: + Even though the value in chassis hardware (e.g. + slot number) may be labelled from 0, 1, 2, and up, + all the indices in MIB start with 1 (not 0) + according to network management convention." + ::= { jnxContainersEntry 2 } + + jnxContainersLevel OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The abstraction level of the box or chassis. + It is enumerated from the outside to the inside, + from the outer layer to the inner layer. + For example, top level (i.e. level 0) refers to + chassis frame, level 1 FPC slot within chassis + frame, level 2 PIC space within FPC slot." + ::= { jnxContainersEntry 3 } + + jnxContainersWithin OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The index of its next higher level container + housing this entry. The associated + jnxContainersIndex in the jnxContainersTable + represents its next higher level container." + ::= { jnxContainersEntry 4 } + + jnxContainersType OBJECT-TYPE + SYNTAX OBJECT IDENTIFIER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The type of this container." + ::= { jnxContainersEntry 5 } + + jnxContainersDescr OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..255)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The name or detailed description of this + subject." + ::= { jnxContainersEntry 6 } + + jnxContainersCount OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The maximum number of containers of this level + per container of the next higher level. + e.g. if there are six level 2 containers in + level 1 container, then jnxContainersCount for + level 2 is six." + ::= { jnxContainersEntry 7 } + +-- +-- Box Contents Table +-- + + jnxContentsLastChange OBJECT-TYPE + SYNTAX TimeStamp + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The value of sysUpTime when the box contents + table last changed. Zero if unknown or already + existing when the agent was up." + ::= { jnxBoxAnatomy 7 } + + jnxContentsTable OBJECT-TYPE + SYNTAX SEQUENCE OF JnxContentsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of contents entries." + ::= { jnxBoxAnatomy 8 } + + jnxContentsEntry OBJECT-TYPE + SYNTAX JnxContentsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry of contents table." + INDEX { jnxContentsContainerIndex, + jnxContentsL1Index, + jnxContentsL2Index, + jnxContentsL3Index } + ::= { jnxContentsTable 1 } + + JnxContentsEntry ::= SEQUENCE { + jnxContentsContainerIndex Integer32, + jnxContentsL1Index Integer32, + jnxContentsL2Index Integer32, + jnxContentsL3Index Integer32, + jnxContentsType OBJECT IDENTIFIER, + jnxContentsDescr DisplayString, + jnxContentsSerialNo DisplayString, + jnxContentsRevision DisplayString, + jnxContentsInstalled TimeStamp, + jnxContentsPartNo DisplayString, + jnxContentsChassisId JnxChassisId, + jnxContentsChassisDescr DisplayString, + jnxContentsChassisCleiCode DisplayString, + jnxContentsModel DisplayString + } + + jnxContentsContainerIndex OBJECT-TYPE + SYNTAX Integer32 (1..'7fffffff'h) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The associated jnxContainersIndex in the + jnxContainersTable." + ::= { jnxContentsEntry 1 } + + jnxContentsL1Index OBJECT-TYPE + SYNTAX Integer32 (0..'7fffffff'h) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The level one index of the container + housing this subject. Zero if unavailable + or inapplicable." + ::= { jnxContentsEntry 2 } + + jnxContentsL2Index OBJECT-TYPE + SYNTAX Integer32 (0..'7fffffff'h) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The level two index of the container + housing this subject. Zero if unavailable + or inapplicable." + ::= { jnxContentsEntry 3 } + + jnxContentsL3Index OBJECT-TYPE + SYNTAX Integer32 (0..'7fffffff'h) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The level three index of the container + housing this subject. Zero if unavailable + or inapplicable." + ::= { jnxContentsEntry 4 } + + jnxContentsType OBJECT-TYPE + SYNTAX OBJECT IDENTIFIER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The type of this subject. zeroDotZero + if unknown." + ::= { jnxContentsEntry 5 } + + jnxContentsDescr OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..255)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The name or detailed description of this + subject." + ::= { jnxContentsEntry 6 } + + jnxContentsSerialNo OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..255)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The serial number of this subject, blank if + unknown or unavailable." + ::= { jnxContentsEntry 7 } + + jnxContentsRevision OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..255)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The revision of this subject, blank if unknown + or unavailable." + ::= { jnxContentsEntry 8 } + + jnxContentsInstalled OBJECT-TYPE + SYNTAX TimeStamp + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The value of sysUpTime when the subject was last + installed, up-and-running. Zero if unknown + or already up-and-running when the agent was up." + ::= { jnxContentsEntry 9 } + + jnxContentsPartNo OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..255)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The part number of this subject, blank if unknown + or unavailable." + ::= { jnxContentsEntry 10 } + + jnxContentsChassisId OBJECT-TYPE + SYNTAX JnxChassisId + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Identifies the chassis on which the contents of this + row exists." + ::= { jnxContentsEntry 11 } + + jnxContentsChassisDescr OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..255)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A textual description of the chassis on which the + contents of this row exists." + ::= { jnxContentsEntry 12 } + + jnxContentsChassisCleiCode OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..255)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The clei code of this subject, blank if unknown + or unavailable. + + A CLEI code is an intelligent code that consists of 10 + alphanumeric characters with 4 data elements. The first data + element is considered the basic code with the first 2 characters + indicating the technology or equipment type, and the third and + fourth characters denoting the functional sub-category. The + second data element represents the features, and its three + characters denote functional capabilities or changes. The third + data element has one character and denotes a reference to a + manufacturer, system ID, specification, or drawing. The fourth + data element consists of two characters and contains complementary + data. These two characters provide a means of differentiating or + providing uniqueness between the eight character CLEI codes by + identifying the manufacturing vintage of the product. Names are + assigned via procedures defined in [GR485]. + + The assigned maintenance agent for the CLEI code, Telcordia + Technologies, is responsible for assigning certain equipment and + other identifiers (e.g., location, manufacturer/supplier) for the + telecommunications industry." + ::= { jnxContentsEntry 13 } + + jnxContentsModel OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..255)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The FRU model name of this subject, blank if unknown + or unavailable." + ::= { jnxContentsEntry 14 } + + + +-- +-- Box LED Indicators Table +-- + + jnxLEDLastChange OBJECT-TYPE + SYNTAX TimeStamp + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "The value of sysUpTime when the box LED table + last changed. Zero if unknown or already at + that state when the agent was up." + ::= { jnxBoxAnatomy 9 } + + jnxLEDTable OBJECT-TYPE + SYNTAX SEQUENCE OF JnxLEDEntry + MAX-ACCESS not-accessible + STATUS deprecated + DESCRIPTION + "A list of status entries." + ::= { jnxBoxAnatomy 10 } + + jnxLEDEntry OBJECT-TYPE + SYNTAX JnxLEDEntry + MAX-ACCESS not-accessible + STATUS deprecated + DESCRIPTION + "An entry of status table." + INDEX { jnxLEDAssociateTable, + jnxLEDAssociateIndex, + jnxLEDL1Index, + jnxLEDL2Index, + jnxLEDL3Index } + ::= { jnxLEDTable 1 } + + JnxLEDEntry ::= SEQUENCE { + jnxLEDAssociateTable INTEGER, + jnxLEDAssociateIndex Integer32, + jnxLEDL1Index Integer32, + jnxLEDL2Index Integer32, + jnxLEDL3Index Integer32, + jnxLEDOriginator OBJECT IDENTIFIER, + jnxLEDDescr DisplayString, + jnxLEDState INTEGER, + jnxLEDStateOrdered INTEGER + } + + jnxLEDAssociateTable OBJECT-TYPE + SYNTAX INTEGER { + other(1), + jnxContainersTable(2), + jnxContentsTable(3) + } + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "The associated table that this entry is + related." + ::= { jnxLEDEntry 1 } + + jnxLEDAssociateIndex OBJECT-TYPE + SYNTAX Integer32 (1..'7fffffff'h) + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "The index of the associated table that this + entry is related." + ::= { jnxLEDEntry 2 } + + jnxLEDL1Index OBJECT-TYPE + SYNTAX Integer32 (0..'7fffffff'h) + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "The level one index of the associated + table that this entry is related. Zero + if unavailable or inapplicable." + ::= { jnxLEDEntry 3 } + + jnxLEDL2Index OBJECT-TYPE + SYNTAX Integer32 (0..'7fffffff'h) + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "The level two index of the associated + table that this entry is related. Zero + if unavailable or inapplicable." + ::= { jnxLEDEntry 4 } + + jnxLEDL3Index OBJECT-TYPE + SYNTAX Integer32 (0..'7fffffff'h) + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "The level three index of the associated + table that this entry is related. Zero + if unavailable or inapplicable." + ::= { jnxLEDEntry 5 } + + jnxLEDOriginator OBJECT-TYPE + SYNTAX OBJECT IDENTIFIER + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "The originator of the this entry." + ::= { jnxLEDEntry 6 } + + jnxLEDDescr OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..255)) + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "The name or detailed description of this subject." + ::= { jnxLEDEntry 7 } + + jnxLEDState OBJECT-TYPE + SYNTAX INTEGER { + other(1), -- unknown or unavailable + green(2), -- ok, good, normally working, + -- or on-line as a standby backup if + -- there is an active primary + yellow(3), -- alarm, warning, marginally working + red(4), -- alert, failed, not working + blue(5), -- ok, on-line as an active primary + amber(6), -- alarm, off-line, not running + off(7), -- off-line, not running + blinkingGreen(8), -- entering state of ok, good, normally working + blinkingYellow(9), -- entering state of alarm, warning, marginally working + blinkingRed(10), -- entering state of alert, failed, not working + blinkingBlue(11), -- entering state of ok, on-line as an active primary + blinkingAmber(12) -- entering state of alarm, off-line, not running + } + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "The state of the LED indicator." + ::= { jnxLEDEntry 8 } + + jnxLEDStateOrdered OBJECT-TYPE + SYNTAX INTEGER { + blue(1), -- ok, on-line as an active primary + green(2), -- ok, good, normally working, + -- or on-line as a standby backup if + -- there is an active primary + amber(3), -- alarm, off-line, not running + yellow(4), -- alarm, warning, marginally working + red(5), -- alert, failed, not working + other(6), -- unknown or unavailable + off(7), -- off-line, not running + blinkingBlue(8), -- entering state of ok, on-line as an active primary + blinkingGreen(9), -- entering state of ok, good, normally working + blinkingAmber(10), -- entering state of alarm, off-line, not running + blinkingYellow(11), -- entering state of alarm, warning, marginally working + blinkingRed(12) -- entering state of alert, failed, not working + } + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "The state of the LED indicator. Identical to jnxLEDState, but + with enums ordered from 'most operational' to 'least + operational' states." + ::= { jnxLEDEntry 9 } +-- +-- Box Filled Status Table +-- +-- This table show the empty/filled status of the container in the +-- box containers table. +-- + + jnxFilledLastChange OBJECT-TYPE + SYNTAX TimeStamp + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The value of sysUpTime when the box filled + status table last changed. Zero if unknown or + already at that state when the agent was up." + ::= { jnxBoxAnatomy 11 } + + jnxFilledTable OBJECT-TYPE + SYNTAX SEQUENCE OF JnxFilledEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of filled status entries." + ::= { jnxBoxAnatomy 12 } + + jnxFilledEntry OBJECT-TYPE + SYNTAX JnxFilledEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry of filled status table." + INDEX { jnxFilledContainerIndex, + jnxFilledL1Index, + jnxFilledL2Index, + jnxFilledL3Index } + ::= { jnxFilledTable 1 } + + JnxFilledEntry ::= SEQUENCE { + jnxFilledContainerIndex Integer32, + jnxFilledL1Index Integer32, + jnxFilledL2Index Integer32, + jnxFilledL3Index Integer32, + jnxFilledDescr DisplayString, + jnxFilledState INTEGER, + jnxFilledChassisId JnxChassisId, + jnxFilledChassisDescr DisplayString + } + + jnxFilledContainerIndex OBJECT-TYPE + SYNTAX Integer32 (1..'7fffffff'h) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The associated jnxContainersIndex in the + jnxContainersTable." + ::= { jnxFilledEntry 1 } + + jnxFilledL1Index OBJECT-TYPE + SYNTAX Integer32 (0..'7fffffff'h) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The level one index of the container + housing this subject. Zero if unavailable + or inapplicable." + ::= { jnxFilledEntry 2 } + + jnxFilledL2Index OBJECT-TYPE + SYNTAX Integer32 (0..'7fffffff'h) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The level two index of the container + housing this subject. Zero if unavailable + or inapplicable." + ::= { jnxFilledEntry 3 } + + jnxFilledL3Index OBJECT-TYPE + SYNTAX Integer32 (0..'7fffffff'h) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The level three index of the container + housing this subject. Zero if unavailable + or inapplicable." + ::= { jnxFilledEntry 4 } + + jnxFilledDescr OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..255)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The name or detailed description of this + subject." + ::= { jnxFilledEntry 5 } + + jnxFilledState OBJECT-TYPE + SYNTAX INTEGER { + unknown(1), + empty(2), + filled(3) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The filled state of this subject." + ::= { jnxFilledEntry 6 } + + jnxFilledChassisId OBJECT-TYPE + SYNTAX JnxChassisId + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Identifies the chassis on which the contents of this + row exists." + ::= { jnxFilledEntry 7 } + + jnxFilledChassisDescr OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..255)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A textual description of the chassis on which the + contents of this row exists." + ::= { jnxFilledEntry 8 } + + +-- +-- Box Operating Status Table +-- +-- This table reveals the operating status of some subjects +-- of interest in the box contents table. +-- + + jnxOperatingTable OBJECT-TYPE + SYNTAX SEQUENCE OF JnxOperatingEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of operating status entries." + ::= { jnxBoxAnatomy 13 } + + jnxOperatingEntry OBJECT-TYPE + SYNTAX JnxOperatingEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry of operating status table." + INDEX { jnxOperatingContentsIndex, + jnxOperatingL1Index, + jnxOperatingL2Index, + jnxOperatingL3Index } + ::= { jnxOperatingTable 1 } + + JnxOperatingEntry ::= SEQUENCE { + jnxOperatingContentsIndex Integer32, + jnxOperatingL1Index Integer32, + jnxOperatingL2Index Integer32, + jnxOperatingL3Index Integer32, + jnxOperatingDescr DisplayString, + jnxOperatingState INTEGER, + jnxOperatingTemp Gauge32, + jnxOperatingCPU Gauge32, + jnxOperatingISR Gauge32, + jnxOperatingDRAMSize Integer32, + jnxOperatingBuffer Gauge32, + jnxOperatingHeap Gauge32, + jnxOperatingUpTime TimeInterval, + jnxOperatingLastRestart TimeStamp, + jnxOperatingMemory Integer32, + jnxOperatingStateOrdered INTEGER, + jnxOperatingChassisId JnxChassisId, + jnxOperatingChassisDescr DisplayString, + jnxOperatingRestartTime DateAndTime, + jnxOperating1MinLoadAvg Gauge32, + jnxOperating5MinLoadAvg Gauge32, + jnxOperating15MinLoadAvg Gauge32, + jnxOperating1MinAvgCPU Gauge32, + jnxOperating5MinAvgCPU Gauge32, + jnxOperating15MinAvgCPU Gauge32, + jnxOperatingFRUPower Gauge32, + jnxOperatingBufferCP Gauge32, + jnxOperatingMemoryCP Integer32 + } + + jnxOperatingContentsIndex OBJECT-TYPE + SYNTAX Integer32 (1..'7fffffff'h) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The associated jnxContentsContainerIndex in the + jnxContentsTable." + ::= { jnxOperatingEntry 1 } + + jnxOperatingL1Index OBJECT-TYPE + SYNTAX Integer32 (0..'7fffffff'h) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The level one index associated with this + subject. Zero if unavailable or inapplicable." + ::= { jnxOperatingEntry 2 } + + jnxOperatingL2Index OBJECT-TYPE + SYNTAX Integer32 (0..'7fffffff'h) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The level two index associated with this + subject. Zero if unavailable or inapplicable." + ::= { jnxOperatingEntry 3 } + + jnxOperatingL3Index OBJECT-TYPE + SYNTAX Integer32 (0..'7fffffff'h) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The level three index associated with this + subject. Zero if unavailable or inapplicable." + ::= { jnxOperatingEntry 4 } + + jnxOperatingDescr OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..255)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The name or detailed description of this subject." + ::= { jnxOperatingEntry 5 } + + jnxOperatingState OBJECT-TYPE + SYNTAX INTEGER { + unknown(1), + running(2), -- up and running, + -- as a active primary + ready(3), -- ready to run, not running yet + reset(4), -- held in reset, not ready yet + runningAtFullSpeed(5), + -- valid for fans only + down(6), -- down or off, for power supply + standby(7) -- running as a standby backup + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The operating state of this subject." + ::= { jnxOperatingEntry 6 } + + jnxOperatingTemp OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The temperature in Celsius (degrees C) of this + subject. Zero if unavailable or inapplicable." + ::= { jnxOperatingEntry 7 } + + jnxOperatingCPU OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The CPU utilization in percentage of this + subject. Zero if unavailable or inapplicable." + ::= { jnxOperatingEntry 8 } + + jnxOperatingISR OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The CPU utilization in percentage of this subject + spending in interrupt service routine (ISR). + Zero if unavailable or inapplicable." + ::= { jnxOperatingEntry 9 } + + jnxOperatingDRAMSize OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "The DRAM size in bytes of this subject. + Zero if unavailable or inapplicable." + ::= { jnxOperatingEntry 10 } + + jnxOperatingBuffer OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The buffer pool utilization in percentage + of this subject. Zero if unavailable or + inapplicable." + ::= { jnxOperatingEntry 11 } + + jnxOperatingHeap OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The heap utilization in percentage of + this subject. Zero if unavailable or + inapplicable." + ::= { jnxOperatingEntry 12 } + + jnxOperatingUpTime OBJECT-TYPE + SYNTAX TimeInterval + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "The time interval in 10-millisecond period + that this subject has been up and running. + Zero if unavailable or inapplicable." + ::= { jnxOperatingEntry 13 } + + jnxOperatingLastRestart OBJECT-TYPE + SYNTAX TimeStamp + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The value of sysUpTime when this subject + last restarted. Zero if unavailable or + inapplicable." + ::= { jnxOperatingEntry 14 } + + jnxOperatingMemory OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The installed memory size in Megabytes + of this subject. Zero if unavailable or + inapplicable." + ::= { jnxOperatingEntry 15 } + + jnxOperatingStateOrdered OBJECT-TYPE + SYNTAX INTEGER { + running(1), -- up and running, + -- as a active primary + standby(2), -- running as a standby backup + ready(3), -- ready to run, not running yet + runningAtFullSpeed(4), + -- valid for fans only + reset(5), -- held in reset, not ready yet + down(6), -- down or off, for power supply + unknown(7) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The operating state of this subject. Identical to + jnxOperatingState, but with enums ordered from 'most + operational' to 'least operational' states." + ::= { jnxOperatingEntry 16 } + + jnxOperatingChassisId OBJECT-TYPE + SYNTAX JnxChassisId + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Identifies the chassis on which the contents of this + row exists." + ::= { jnxOperatingEntry 17 } + + jnxOperatingChassisDescr OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..255)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A textual description of the chassis on which the + contents of this row exists." + ::= { jnxOperatingEntry 18 } + + jnxOperatingRestartTime OBJECT-TYPE + SYNTAX DateAndTime + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The time at which this entity + last restarted." + ::= { jnxOperatingEntry 19 } + + jnxOperating1MinLoadAvg OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The CPU Load Average over the last 1 minutes + Here it will be shown as percentage value + Zero if unavailable or inapplicable." + ::= { jnxOperatingEntry 20 } + + jnxOperating5MinLoadAvg OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The CPU Load Average over the last 5 minutes + Here it will be shown as percentage value + Zero if unavailable or inapplicable." + ::= { jnxOperatingEntry 21 } + + jnxOperating15MinLoadAvg OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The CPU Load Average over the last 15 minutes + Here it will be shown as percentage value + Zero if unavailable or inapplicable." + ::= { jnxOperatingEntry 22 } + + jnxOperating1MinAvgCPU OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The CPU utilization in percentage of this + subject averaged over last 1 minutes. Zero if + unavailable or inapplicable." + ::= { jnxOperatingEntry 23 } + + jnxOperating5MinAvgCPU OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The CPU utilization in percentage of this + subject averaged over last 5 minutes. Zero if + unavailable or inapplicable." + ::= { jnxOperatingEntry 24 } + + jnxOperating15MinAvgCPU OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The CPU utilization in percentage of this + subject averaged over last 15 minutes. Zero + if unavailable or inapplicable." + ::= { jnxOperatingEntry 25 } + + jnxOperatingFRUPower OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The present power of each FRU. Here it will + be shown in terms of voltage. Zero if unavailable + or inapplicable" + ::= { jnxOperatingEntry 26 } + + jnxOperatingBufferCP OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The buffer pool utilization in percentage + of this subject in control plane. Zero if + unavailable or inapplicable." + ::= { jnxOperatingEntry 27 } + + jnxOperatingMemoryCP OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The Allocated memory size for control plane + in Megabytes. Zero if unavailable or + inapplicable." + ::= { jnxOperatingEntry 28 } + +-- +-- Box Redundancy Information Table +-- +-- This table shows the internal configuration setting for the +-- available redundant subsystems or components in the box. +-- + + jnxRedundancyTable OBJECT-TYPE + SYNTAX SEQUENCE OF JnxRedundancyEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of redundancy information entries." + ::= { jnxBoxAnatomy 14 } + + jnxRedundancyEntry OBJECT-TYPE + SYNTAX JnxRedundancyEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry in the redundancy information table." + INDEX { jnxRedundancyContentsIndex, + jnxRedundancyL1Index, + jnxRedundancyL2Index, + jnxRedundancyL3Index } + ::= { jnxRedundancyTable 1 } + + JnxRedundancyEntry ::= SEQUENCE { + jnxRedundancyContentsIndex Integer32, + jnxRedundancyL1Index Integer32, + jnxRedundancyL2Index Integer32, + jnxRedundancyL3Index Integer32, + jnxRedundancyDescr DisplayString, + jnxRedundancyConfig INTEGER, + jnxRedundancyState INTEGER, + jnxRedundancySwitchoverCount Counter32, + jnxRedundancySwitchoverTime TimeStamp, + jnxRedundancySwitchoverReason INTEGER, + jnxRedundancyKeepaliveHeartbeat Integer32, + jnxRedundancyKeepaliveTimeout Integer32, + jnxRedundancyKeepaliveElapsed Integer32, + jnxRedundancyKeepaliveLoss Counter32, + jnxRedundancyChassisId JnxChassisId, + jnxRedundancyChassisDescr DisplayString + } + + jnxRedundancyContentsIndex OBJECT-TYPE + SYNTAX Integer32 (1..'7fffffff'h) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The associated jnxContentsContainerIndex in the + jnxContentsTable." + ::= { jnxRedundancyEntry 1 } + + jnxRedundancyL1Index OBJECT-TYPE + SYNTAX Integer32 (0..'7fffffff'h) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The level one index associated with this + subject. Zero if unavailable or inapplicable." + ::= { jnxRedundancyEntry 2 } + + jnxRedundancyL2Index OBJECT-TYPE + SYNTAX Integer32 (0..'7fffffff'h) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The level two index associated with this + subject. Zero if unavailable or inapplicable." + ::= { jnxRedundancyEntry 3 } + + jnxRedundancyL3Index OBJECT-TYPE + SYNTAX Integer32 (0..'7fffffff'h) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The level three index associated with this + subject. Zero if unavailable or inapplicable." + ::= { jnxRedundancyEntry 4 } + + jnxRedundancyDescr OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..255)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The name or detailed description of this subject." + ::= { jnxRedundancyEntry 5 } + + jnxRedundancyConfig OBJECT-TYPE + SYNTAX INTEGER { + unknown(1), + master(2), -- election priority set as a master + backup(3), -- election priority set as a backup + disabled(4), -- election disabled + notApplicable(5) -- any among the available can be master + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The election priority of redundancy configuration for + this subject. The value 'notApplicable' means no + specific instance is configured to be master or + backup; whichever component boots up first becomes a + master." + ::= { jnxRedundancyEntry 6 } + + jnxRedundancyState OBJECT-TYPE + SYNTAX INTEGER { + unknown(1), + master(2), -- master + backup(3), -- backup + disabled(4) -- disabled + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current running state for this subject." + ::= { jnxRedundancyEntry 7 } + + jnxRedundancySwitchoverCount OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The total number of switchover as perceived by + this subject since routing engine is up and running. + The switchover is defined as a change in state of + jnxRedundancyState from master to backup or vice + versa. Its value is reset when the routing engine + is reset or rebooted." + ::= { jnxRedundancyEntry 8 } + + jnxRedundancySwitchoverTime OBJECT-TYPE + SYNTAX TimeStamp + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The value of sysUpTime when the jnxRedundancyState + of this subject was last switched over from master + to backup or vice versa. Zero if unknown or never + switched over since the routing engine is up and + running." + ::= { jnxRedundancyEntry 9 } + + jnxRedundancySwitchoverReason OBJECT-TYPE + SYNTAX INTEGER { + other(1), -- others + neverSwitched(2), -- never switched + userSwitched(3), -- user-initiated switchover + autoSwitched(4) -- automatic switchover + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The reason of the last switchover for this subject." + ::= { jnxRedundancyEntry 10 } + + jnxRedundancyKeepaliveHeartbeat OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The period of sending keepalive messages between + the master and backup subsystems. It is a system-wide + preset value in seconds used by internal mastership + resolution. Zero if unavailable or inapplicable." + ::= { jnxRedundancyEntry 11 } + + jnxRedundancyKeepaliveTimeout OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The timeout period in seconds, by the keepalive + watchdog timer, before initiating a switch over to + the backup subsystem. Zero if unavailable or + inapplicable." + ::= { jnxRedundancyEntry 12 } + + jnxRedundancyKeepaliveElapsed OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The elapsed time in seconds by this subject since + receiving the last keepalive message from the other + subsystems. Zero if unavailable or inapplicable." + ::= { jnxRedundancyEntry 13 } + + jnxRedundancyKeepaliveLoss OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The total number of losses on keepalive messages + between the master and backup subsystems as perceived + by this subject since the system is up and running. + Zero if unavailable or inapplicable." + ::= { jnxRedundancyEntry 14 } + + jnxRedundancyChassisId OBJECT-TYPE + SYNTAX JnxChassisId + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Identifies the chassis on which the contents of this + row exists." + ::= { jnxRedundancyEntry 15 } + + jnxRedundancyChassisDescr OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..255)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A textual description of the chassis on which the + contents of this row exists." + ::= { jnxRedundancyEntry 16 } + + +-- +-- FRU (Field Replaceable Unit) Status Table +-- +-- This table shows the status of the FRUs in the chassis. +-- + + jnxFruTable OBJECT-TYPE + SYNTAX SEQUENCE OF JnxFruEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of FRU status entries." + ::= { jnxBoxAnatomy 15 } + + jnxFruEntry OBJECT-TYPE + SYNTAX JnxFruEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry in the FRU status table." + INDEX { jnxFruContentsIndex, + jnxFruL1Index, + jnxFruL2Index, + jnxFruL3Index } + ::= { jnxFruTable 1 } + + JnxFruEntry ::= SEQUENCE { + jnxFruContentsIndex Integer32, + jnxFruL1Index Integer32, + jnxFruL2Index Integer32, + jnxFruL3Index Integer32, + jnxFruName DisplayString, + jnxFruType INTEGER, + jnxFruSlot Integer32, + jnxFruState INTEGER, + jnxFruTemp Gauge32, + jnxFruOfflineReason INTEGER, + jnxFruLastPowerOff TimeStamp, + jnxFruLastPowerOn TimeStamp, + jnxFruPowerUpTime TimeInterval, + jnxFruChassisId JnxChassisId, + jnxFruChassisDescr DisplayString, + jnxFruPsdAssignment Integer32 + } + + jnxFruContentsIndex OBJECT-TYPE + SYNTAX Integer32 (1..'7fffffff'h) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The associated jnxContentsContainerIndex in the + jnxContentsTable." + ::= { jnxFruEntry 1 } + + jnxFruL1Index OBJECT-TYPE + SYNTAX Integer32 (0..'7fffffff'h) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The level one index associated with this + subject. Zero if unavailable or inapplicable." + ::= { jnxFruEntry 2 } + + jnxFruL2Index OBJECT-TYPE + SYNTAX Integer32 (0..'7fffffff'h) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The level two index associated with this + subject. Zero if unavailable or inapplicable." + ::= { jnxFruEntry 3 } + + jnxFruL3Index OBJECT-TYPE + SYNTAX Integer32 (0..'7fffffff'h) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The level three index associated with this + subject. Zero if unavailable or inapplicable." + ::= { jnxFruEntry 4 } + + jnxFruName OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..255)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The name or detailed description of this subject." + ::= { jnxFruEntry 5 } + + jnxFruType OBJECT-TYPE + SYNTAX INTEGER { + other(1), -- unknown or others + clockGenerator(2), -- CG + flexiblePicConcentrator(3), -- FPC + switchingAndForwardingModule(4), -- SFM + controlBoard(5), -- CBD, SCB + routingEngine(6), -- RE + powerEntryModule(7), -- PEM + frontPanelModule(8), -- FPM + switchInterfaceBoard(9), -- SIB + processorMezzanineBoardForSIB(10), -- SPMB + portInterfaceCard(11), -- PIC + craftInterfacePanel(12), -- CIP + fan(13), -- fan + lineCardChassis(14), -- LCC + forwardingEngineBoard(15), -- FEB + protectedSystemDomain(16), -- PSD + powerDistributionUnit(17), -- PDU + powerSupplyModule(18), -- PSM + switchFabricBoard(19), -- SFB + adapterCard(20) -- ADC + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The FRU type for this subject." + ::= { jnxFruEntry 6 } + + jnxFruSlot OBJECT-TYPE + SYNTAX Integer32 (0..'7fffffff'h) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The slot number of this subject. This is equivalent + to jnxFruL1Index in meaning. Zero if unavailable or + inapplicable." + ::= { jnxFruEntry 7 } + + jnxFruState OBJECT-TYPE + SYNTAX INTEGER { + unknown(1), + empty(2), + present(3), + ready(4), + announceOnline(5), + online(6), + anounceOffline(7), + offline(8), + diagnostic(9), + standby(10) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current state for this subject." + ::= { jnxFruEntry 8 } + + jnxFruTemp OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The temperature in Celsius (degrees C) of this + subject. Zero if unavailable or inapplicable." + ::= { jnxFruEntry 9 } + + jnxFruOfflineReason OBJECT-TYPE + SYNTAX INTEGER { + unknown(1), -- unknown or other + none(2), -- none + error(3), -- error + noPower(4), -- no power + configPowerOff(5), -- configured to power off + configHoldInReset(6), -- configured to hold in reset + cliCommand(7), -- offlined by cli command + buttonPress(8), -- offlined by button press + cliRestart(9), -- restarted by cli command + overtempShutdown(10), -- overtemperature shutdown + masterClockDown(11), -- master clock down + singleSfmModeChange(12), -- single SFM mode change + packetSchedulingModeChange(13), -- packet scheduling mode change + physicalRemoval(14), -- physical removal + unresponsiveRestart(15), -- restarting unresponsive board + sonetClockAbsent(16), -- sonet out clock absent + rddPowerOff(17), -- RDD power off + majorErrors(18), -- major errors + minorErrors(19), -- minor errors + lccHardRestart(20), -- LCC hard restart + lccVersionMismatch(21), -- LCC version mismatch + powerCycle(22), -- power cycle + reconnect(23), -- reconnect + overvoltage(24), -- overvoltage + pfeVersionMismatch(25), -- PFE version mismatch + febRddCfgChange(26), -- FEB redundancy cfg changed + fpcMisconfig(27), -- FPC is misconfigured + fruReconnectFail(28), -- FRU did not reconnect + fruFwddReset(29), -- FWDD reset the fru + fruFebSwitch(30), -- FEB got switched + fruFebOffline(31), -- FEB was offlined + fruInServSoftUpgradeError(32), -- In Service Software Upgrade Error + fruChasdPowerRatingExceed(33), -- Chassis power rating exceeded + fruConfigOffline(34), -- Configured offline + fruServiceRestartRequest(35), -- restarting request from a service + spuResetRequest(36), -- SPU reset request + spuFlowdDown(37), -- SPU flowd down + spuSpi4Down(38), -- SPU SPI4 down + spuWatchdogTimeout(39), -- SPU Watchdog timeout + spuCoreDump(40), -- SPU kernel core dump + fpgaSpi4LinkDown(41), -- FPGA SPI4 link down + i3Spi4LinkDown(42), -- I3 SPI4 link down + cppDisconnect(43), -- CPP disconnect + cpuNotBoot(44), -- CPU not boot + spuCoreDumpComplete(45), -- SPU kernel core dump complete + rstOnSpcSpuFailure(46), -- Rst on SPC SPU failure + softRstOnSpcSpuFailure(47), -- Soft Reset on SPC SPU failure + hwAuthenticationFailure(48), -- HW authentication failure + reconnectFpcFail(49), -- Reconnect FPC fail + fpcAppFailed(50), -- FPC app failed + fpcKernelCrash(51), -- FPC kernel crash + spuFlowdDownNoCore(52), -- SPU flowd down, no core dump + spuFlowdCoreDumpIncomplete(53), -- SPU flowd crash with incomplete core dump + spuFlowdCoreDumpComplete(54), -- SPU flowd crash with complete core dump + spuIdpdDownNoCore(55), -- SPU idpd down, no core dump + spuIdpdCoreDumpIncomplete(56), -- SPU idpd crash with incomplete core dump + spuIdpdCoreDumpComplete(57), -- SPU idpd crash with complete core dump + spuCoreDumpIncomplete(58), -- SPU kernel crash with incomplete core dump + spuIdpdDown(59), -- SPU idpd down + fruPfeReset(60), -- PFE reset + fruReconnectNotReady(61), -- FPC not ready to reconnect + fruSfLinkDown(62), -- FE - Fabric links down + fruFabricDown(63), -- Fabric transitioned from up to down + fruAntiCounterfeitRetry(64), -- FPC offlined due to Anti Counterfeit Retry + fruFPCChassisClusterDisable(65), -- FPC offlined due to Chassis Cluster Disable + spuFipsError(66), -- SPU fips error + fruFPCFabricDownOffline(67), -- FPC offlined due to Fabric down + febCfgChange(68), -- FEB config change + routeLocalizationRoleChange(69), -- Route localization role change + fruFpcUnsupported(70), -- FPC unsupported + psdVersionMismatch(71), -- PSD version mismatch + fruResetThresholdExceeded(72), -- FRU Reset Threshold Exceeded + picBounce(73), -- PIC Bounce + badVoltage(74), -- bad voltage + fruFPCReducedFabricBW(75), -- FPC offlined due to Reduced Fabric Bandwidth + fruAutoheal(76), -- FRU offlined due to software autoheal action + builtinPicBounce(77), -- Builtin PIC Bounce + fruFabricDegraded(78), -- Fabric running in degraded state + fruFPCFabricDegradedOffline(79), -- FPC offlined due to degraded fabric action + fruUnsupportedSlot(80), -- FRU unsupported in the current slot + fruRouteLocalizationMisCfg(81), -- Route Localization - FPC Misconfiguration + fruTypeConfigMismatch(82), -- FRU Type configuration mismatch + lccModeChanged(83), -- LCC mode changed on the SFC + hwFault(84), -- Hardware fault + fruPICOfflineOnEccErrors(85), -- PIC offlined on ecc errors cross ceratins limit. + fruFpcIncompatible(86), -- FPC imcompatible with other FPCs + fruFpcFanTrayPEMIncompatible(87),-- FPC incompatible with FAN-TRAYs ,PEMs + fruUnsupportedFirmware(88), -- Firmware on this FRU not supported + openflowConfigChange(89), -- Openflow config change offlines FPC + fruFpcScbIncompatible(90), -- FPC incompatible with SCB + fruReUnresponsive(91), -- Corresponding slot RE unresponsive + hwError(92), -- Hardware error + fruErrorManagerReqFPCReset(93), -- Error manager requested FPC reset. + fruIncompatibleWithPEM(94), -- FRU incompatible with power supply + fruIncompatibleWithSIB(95), -- FRU incompatible with SIB + sibIncompatibleWithOtherSIB(96), -- FRU incompatible with other SIB + fruPfeErrors(97), -- PIC offlined on PFE Errors cross limit. + vpnLocalizationRoleChange(98), -- VPN localization core-facing-FPC role change + fruFpcFanTrayIncompatible(99), -- FPC incompatible with FAN-TRAYs + fruFpcPEMIncompatible(100), -- FPC incompatible with PEMs + mixedSwitchFabric(101), -- Mixed Switch Fabric error + unsupportedFabric(102), -- unsupported Fabric error + jamConfigError(103), -- JAM configuration error + fruFpcHFanTrayIncompatible(104), -- FPC incompatible with Horizontal FAN-TRAYs + gnfIsOffline(105), -- GNF is Offline + gnfdisconnected(106), -- GNF disconnected + fruIncompatibleWithVersion(107), -- Incompatibile with BSYS + reasonOfflineEnd(108) -- Unknown + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The offline reason of this subject." + ::= { jnxFruEntry 10 } + + jnxFruLastPowerOff OBJECT-TYPE + SYNTAX TimeStamp + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The value of sysUpTime when this subject was last + powered off. Zero if unavailable or inapplicable." + ::= { jnxFruEntry 11 } + + jnxFruLastPowerOn OBJECT-TYPE + SYNTAX TimeStamp + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The value of sysUpTime when this subject was last + powered on. Zero if unavailable or inapplicable." + ::= { jnxFruEntry 12 } + + jnxFruPowerUpTime OBJECT-TYPE + SYNTAX TimeInterval + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The time interval in 10-millisecond period + that this subject has been up and running + since the last power on time. Zero if + unavailable or inapplicable." + ::= { jnxFruEntry 13 } + + jnxFruChassisId OBJECT-TYPE + SYNTAX JnxChassisId + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Identifies the chassis on which the contents of this + row exists." + ::= { jnxFruEntry 14 } + + jnxFruChassisDescr OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..255)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A textual description of the chassis on which the + contents of this row exists." + ::= { jnxFruEntry 15 } + + jnxFruPsdAssignment OBJECT-TYPE + SYNTAX Integer32 (0..31) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The PSD assignment of this subject. Zero if unavailable or + not applicable." + ::= { jnxFruEntry 16 } + +-- +-- definition of Kernel Memory Used related stuff +-- + + jnxBoxKernelMemoryUsedPercent OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The percentage of kernel memory used + of this subject. 0 if unavailable or + inapplicable." + ::= { jnxBoxAnatomy 16 } + +-- +-- definition of system domain information +-- + + jnxBoxSystemDomainType OBJECT-TYPE + SYNTAX INTEGER { + notApplicable(1), + rootSystemDomain(2), + protectedSystemDomain(3) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The system domain type of this subject, notApplicable will + be returned if this feature is not supported." + ::= { jnxBoxAnatomy 17 } + + +-- +-- Applicable only for MidRangius Systems (MX5/10/40) +-- + jnxBoxPersonality OBJECT-TYPE + SYNTAX OBJECT IDENTIFIER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The personality of the box, indicating which product line it is currently acting as + for example, 'MX40'." + ::= { jnxBoxAnatomy 18 } + + + +-- +-- definition of chassis related traps +-- + -- Traps for chassis alarm conditions + + jnxPowerSupplyFailure NOTIFICATION-TYPE + OBJECTS { jnxContentsContainerIndex, + jnxContentsL1Index, + jnxContentsL2Index, + jnxContentsL3Index, + jnxContentsDescr, + jnxOperatingState } + STATUS current + DESCRIPTION + "A jnxPowerSupplyFailure trap signifies that + the SNMP entity, acting in an agent role, has + detected that the specified power supply in the + chassis has been in the failure (bad DC output) + condition." + ::= { jnxChassisTraps 1 } + + jnxFanFailure NOTIFICATION-TYPE + OBJECTS { jnxContentsContainerIndex, + jnxContentsL1Index, + jnxContentsL2Index, + jnxContentsL3Index, + jnxContentsDescr, + jnxOperatingState } + STATUS current + DESCRIPTION + "A jnxFanFailure trap signifies that the SNMP + entity, acting in an agent role, has detected + that the specified cooling fan or impeller in + the chassis has been in the failure (not spinning) + condition." + ::= { jnxChassisTraps 2 } + + jnxOverTemperature NOTIFICATION-TYPE + OBJECTS { jnxContentsContainerIndex, + jnxContentsL1Index, + jnxContentsL2Index, + jnxContentsL3Index, + jnxContentsDescr, + jnxOperatingTemp } + STATUS current + DESCRIPTION + "A jnxOverTemperature trap signifies that the + SNMP entity, acting in an agent role, has + detected that the specified hardware component + in the chassis has experienced over temperature + condition." + ::= { jnxChassisTraps 3 } + + jnxRedundancySwitchover NOTIFICATION-TYPE + OBJECTS { jnxRedundancyContentsIndex, + jnxRedundancyL1Index, + jnxRedundancyL2Index, + jnxRedundancyL3Index, + jnxRedundancyDescr, + jnxRedundancyConfig, + jnxRedundancyState, + jnxRedundancySwitchoverCount, + jnxRedundancySwitchoverTime, + jnxRedundancySwitchoverReason } + STATUS current + DESCRIPTION + "A jnxRedundancySwitchover trap signifies that + the SNMP entity, acting in an agent role, has + detected that the specified hardware component + in the chassis has experienced a redundancy + switchover event defined as a change in state + of jnxRedundancyState from master to backup or + vice versa." + ::= { jnxChassisTraps 4 } + + jnxFruRemoval NOTIFICATION-TYPE + OBJECTS { jnxFruContentsIndex, + jnxFruL1Index, + jnxFruL2Index, + jnxFruL3Index, + jnxFruName, + jnxFruType, + jnxFruSlot } + STATUS current + DESCRIPTION + "A jnxFruRemoval trap signifies that the SNMP + entity, acting in an agent role, has detected + that the specified FRU (Field Replaceable Unit) + has been removed from the chassis." + ::= { jnxChassisTraps 5 } + + jnxFruInsertion NOTIFICATION-TYPE + OBJECTS { jnxFruContentsIndex, + jnxFruL1Index, + jnxFruL2Index, + jnxFruL3Index, + jnxFruName, + jnxFruType, + jnxFruSlot } + STATUS current + DESCRIPTION + "A jnxFruInsertion trap signifies that the SNMP + entity, acting in an agent role, has detected that + the specified FRU (Field Replaceable Unit) has been + inserted into the chassis." + ::= { jnxChassisTraps 6 } + + jnxFruPowerOff NOTIFICATION-TYPE + OBJECTS { jnxFruContentsIndex, + jnxFruL1Index, + jnxFruL2Index, + jnxFruL3Index, + jnxFruName, + jnxFruType, + jnxFruSlot, + jnxFruOfflineReason, + jnxFruLastPowerOff, + jnxFruLastPowerOn } + STATUS current + DESCRIPTION + "A jnxFruPowerOff trap signifies that the SNMP + entity, acting in an agent role, has detected + that the specified FRU (Field Replaceable Unit) + has been powered off in the chassis." + ::= { jnxChassisTraps 7 } + + jnxFruPowerOn NOTIFICATION-TYPE + OBJECTS { jnxFruContentsIndex, + jnxFruL1Index, + jnxFruL2Index, + jnxFruL3Index, + jnxFruName, + jnxFruType, + jnxFruSlot, + jnxFruOfflineReason, + jnxFruLastPowerOff, + jnxFruLastPowerOn } + STATUS current + DESCRIPTION + "A jnxFruPowerOn trap signifies that the SNMP + entity, acting in an agent role, has detected that + the specified FRU (Field Replaceable Unit) has been + powered on in the chassis." + ::= { jnxChassisTraps 8 } + + jnxFruFailed NOTIFICATION-TYPE + OBJECTS { jnxFruContentsIndex, + jnxFruL1Index, + jnxFruL2Index, + jnxFruL3Index, + jnxFruName, + jnxFruType, + jnxFruSlot } + STATUS current + DESCRIPTION + "This indicates the specified FRU (Field Replaceable Unit) + has failed in the chassis. Most probably this is due toi + some hard error such as fru is not powering up or not + able to load ukernel. In these cases, fru is replaced." + ::= { jnxChassisTraps 9 } + + jnxFruOffline NOTIFICATION-TYPE + OBJECTS { jnxFruContentsIndex, + jnxFruL1Index, + jnxFruL2Index, + jnxFruL3Index, + jnxFruName, + jnxFruType, + jnxFruSlot, + jnxFruOfflineReason, + jnxFruLastPowerOff, + jnxFruLastPowerOn } + STATUS current + DESCRIPTION + "A jnxFruOffline trap signifies that the SNMP + entity, acting in an agent role, has detected + that the specified FRU (Field Replaceable Unit) + has gone offline in the chassis." + ::= { jnxChassisTraps 10 } + + jnxFruOnline NOTIFICATION-TYPE + OBJECTS { jnxFruContentsIndex, + jnxFruL1Index, + jnxFruL2Index, + jnxFruL3Index, + jnxFruName, + jnxFruType, + jnxFruSlot } + STATUS current + DESCRIPTION + "A jnxFruOnline trap signifies that the SNMP + entity, acting in an agent role, has detected that + the specified FRU (Field Replaceable Unit) has + gone online in the chassis." + ::= { jnxChassisTraps 11 } + + jnxFruCheck NOTIFICATION-TYPE + OBJECTS { jnxFruContentsIndex, + jnxFruL1Index, + jnxFruL2Index, + jnxFruL3Index, + jnxFruName, + jnxFruType, + jnxFruSlot } + STATUS current + DESCRIPTION + "A jnxFruCheck trap signifies that the SNMP + entity, acting in an agent role, has detected that + the specified FRU (Field Replaceable Unit) has + encountered some operational errors and gone into + check state in the chassis." + ::= { jnxChassisTraps 12 } + + jnxFEBSwitchover NOTIFICATION-TYPE + OBJECTS { jnxFruContentsIndex, + jnxFruL1Index, + jnxFruL2Index, + jnxFruL3Index, + jnxFruName, + jnxFruType, + jnxFruSlot } + STATUS current + DESCRIPTION + "A jnxFEBSwitchover trap signifies that the SNMP + entity, acting in an agent role, has detected that + the specified FEB (Forwarding Engine Board) has + switched over." + ::= { jnxChassisTraps 13 } + + jnxHardDiskFailed NOTIFICATION-TYPE + OBJECTS { jnxFruContentsIndex, + jnxFruL1Index, + jnxFruL2Index, + jnxFruL3Index, + jnxFruName, + jnxFruType, + jnxFruSlot } + STATUS current + DESCRIPTION + "A jnxHardDiskFailed trap signifies that the SNMP + entity, acting in an agent role, has detected that + the Disk in the specified Routing Engine has + encountered some operational errors and gone into + failed state in the chassis." + ::= { jnxChassisTraps 14 } + + jnxHardDiskMissing NOTIFICATION-TYPE + OBJECTS { jnxFruContentsIndex, + jnxFruL1Index, + jnxFruL2Index, + jnxFruL3Index, + jnxFruName, + jnxFruType, + jnxFruSlot } + STATUS current + DESCRIPTION + "A DiskMissing trap signifies that the SNMP + entity, acting in an agent role, has detected that + hard disk in the specified outing Engine is missing + from boot device list." + ::= { jnxChassisTraps 15 } + + jnxBootFromBackup NOTIFICATION-TYPE + OBJECTS { jnxFruContentsIndex, + jnxFruL1Index, + jnxFruL2Index, + jnxFruL3Index, + jnxFruName, + jnxFruType, + jnxFruSlot } + STATUS current + DESCRIPTION + "A jnxBootFromBackup trap signifies that the SNMP + entity, acting in an agent role, has detected that + the specified routing-engine/member has booted from + the back up root partition" + ::= { jnxChassisTraps 16 } + + jnxFmLinkErr NOTIFICATION-TYPE + OBJECTS { jnxFruContentsIndex, + jnxFruL1Index, + jnxFruL2Index, + jnxFruL3Index, + jnxFruName, + jnxFruType, + jnxFruSlot } + STATUS current + DESCRIPTION + "A LinkErr trap signifies that the SNMP + entity, acting in an agent role, has detected + link errors." + ::= { jnxChassisTraps 17 } + + jnxFmCellDropErr NOTIFICATION-TYPE + OBJECTS { jnxFruContentsIndex, + jnxFruL1Index, + jnxFruL2Index, + jnxFruL3Index, + jnxFruName, + jnxFruType, + jnxFruSlot } + STATUS current + DESCRIPTION + "A CellDropErr trap signifies that the SNMP + entity, acting in an agent role, has detected + cell drop errors." + ::= { jnxChassisTraps 18 } + + jnxExtSrcLockLost NOTIFICATION-TYPE + OBJECTS { jnxFruContentsIndex, + jnxFruL1Index, + jnxFruL2Index, + jnxFruL3Index, + jnxFruName, + jnxFruType, + jnxFruSlot } + STATUS current + DESCRIPTION + "A ExtSrcLockLost trap signifies that the SNMP + entity, acting in an agent role, has detected that + a lock for an external clock source has been lost." + ::= { jnxChassisTraps 19 } + jnxPlaneOffline NOTIFICATION-TYPE + OBJECTS { jnxFruContentsIndex, + jnxFruL1Index, + jnxFruL2Index, + jnxFruL3Index, + jnxFruName, + jnxFruType, + jnxFruSlot, + jnxFruOfflineReason, + jnxFruLastPowerOff, + jnxFruLastPowerOn } + STATUS current + DESCRIPTION + "A jnxPlaneOffline trap signifies that the SNMP + entity, acting in an agent role, has detected + that the specified Fabric plane + has gone offline in the chassis." + ::= { jnxChassisTraps 20 } + + jnxPlaneOnline NOTIFICATION-TYPE + OBJECTS { jnxFruContentsIndex, + jnxFruL1Index, + jnxFruL2Index, + jnxFruL3Index, + jnxFruName, + jnxFruType, + jnxFruSlot } + STATUS current + DESCRIPTION + "A jnxPlaneOnline trap signifies that the SNMP + entity, acting in an agent role, has detected that + the specified Fabric Plane has + gone online in the chassis." + ::= { jnxChassisTraps 21 } + + jnxPlaneCheck NOTIFICATION-TYPE + OBJECTS { jnxFruContentsIndex, + jnxFruL1Index, + jnxFruL2Index, + jnxFruL3Index, + jnxFruName, + jnxFruType, + jnxFruSlot } + STATUS current + DESCRIPTION + "A jnxPlaneCheck trap signifies that the SNMP + entity, acting in an agent role, has detected that + the specified Fabric plane has + encountered some operational errors and gone into + check state in the chassis." + ::= { jnxChassisTraps 22 } + + jnxPlaneFault NOTIFICATION-TYPE + OBJECTS { jnxFruContentsIndex, + jnxFruL1Index, + jnxFruL2Index, + jnxFruL3Index, + jnxFruName, + jnxFruType, + jnxFruSlot } + STATUS current + DESCRIPTION + "A jnxPlaneCheck trap signifies that the SNMP + entity, acting in an agent role, has detected that + the specified Fabric plane has + encountered some operational errors and gone into + fault state in the chassis." + ::= { jnxChassisTraps 23 } + + jnxPowerSupplyInputFailure NOTIFICATION-TYPE + OBJECTS { jnxContentsContainerIndex, + jnxContentsL1Index, + jnxContentsL2Index, + jnxContentsL3Index, + jnxContentsDescr, + jnxOperatingState } + STATUS current + DESCRIPTION + "A jnxPowerSupplyInputFailure trap signifies that + the SNMP entity, acting in an agent role, has + detected that the specified power supply's input feed + in the chassis has been in the failure condition." + ::= { jnxChassisTraps 24 } + + jnxFmAsicErr NOTIFICATION-TYPE + OBJECTS { jnxFruContentsIndex, + jnxFruL1Index, + jnxFruL2Index, + jnxFruL3Index, + jnxFruName, + jnxFruType, + jnxFruSlot } + STATUS current + DESCRIPTION + "A jnxFmAsicErr trap signifies that the SNMP + entity, acting in an agent role, has detected + errors in a switching device within the fabric." + ::= { jnxChassisTraps 25 } + + jnxMountVarOffHardDiskFailed NOTIFICATION-TYPE + OBJECTS { jnxFruContentsIndex, + jnxFruL1Index, + jnxFruL2Index, + jnxFruL3Index, + jnxFruName, + jnxFruType, + jnxFruSlot } + STATUS current + DESCRIPTION + "A jnxMountVarOffHardDiskFailed signifies that the SNMP + entity, acting in an agent role, has detected that + mount of /var failed off harddisk, emergency /var created." + ::= { jnxChassisTraps 26 } + + jnxFmHealthChkErr NOTIFICATION-TYPE + OBJECTS { jnxFruContentsIndex, + jnxFruL1Index, + jnxFruL2Index, + jnxFruL3Index, + jnxFruName, + jnxFruType, + jnxFruSlot } + STATUS current + DESCRIPTION + "A HealthChkErr trap signifies that the SNMP + entity, acting in an agent role, has detected + health check errors." + ::= { jnxChassisTraps 27 } + + -- Traps for chassis alarm cleared conditions + + jnxPowerSupplyOK NOTIFICATION-TYPE + OBJECTS { jnxContentsContainerIndex, + jnxContentsL1Index, + jnxContentsL2Index, + jnxContentsL3Index, + jnxContentsDescr, + jnxOperatingState } + STATUS current + DESCRIPTION + "A jnxPowerSupplyOK trap signifies that the + SNMP entity, acting in an agent role, has + detected that the specified power supply in the + chassis has recovered from the failure (bad DC output) + condition." + ::= { jnxChassisOKTraps 1 } + + jnxFanOK NOTIFICATION-TYPE + OBJECTS { jnxContentsContainerIndex, + jnxContentsL1Index, + jnxContentsL2Index, + jnxContentsL3Index, + jnxContentsDescr, + jnxOperatingState } + STATUS current + DESCRIPTION + "A jnxFanOK trap signifies that the SNMP + entity, acting in an agent role, has detected that + the specified cooling fan or impeller in the chassis + has recovered from the failure (not spinning) condition." + ::= { jnxChassisOKTraps 2 } + + jnxTemperatureOK NOTIFICATION-TYPE + OBJECTS { jnxContentsContainerIndex, + jnxContentsL1Index, + jnxContentsL2Index, + jnxContentsL3Index, + jnxContentsDescr, + jnxOperatingTemp } + STATUS current + DESCRIPTION + "A jnxTemperatureOK trap signifies that the + SNMP entity, acting in an agent role, has + detected that the specified hardware component + in the chassis has recovered from over temperature + condition." + ::= { jnxChassisOKTraps 3 } + + jnxFruOK NOTIFICATION-TYPE + OBJECTS { jnxFruContentsIndex, + jnxFruL1Index, + jnxFruL2Index, + jnxFruL3Index, + jnxFruName, + jnxFruType, + jnxFruSlot } + STATUS current + DESCRIPTION + "A jnxFruOK trap signifies that the SNMP + entity, acting in an agent role, has detected that + the specified FRU (Field Replaceable Unit) has + recovered from previous operational errors and it + is in ok state in the chassis." + ::= { jnxChassisOKTraps 4 } + + jnxExtSrcLockAcquired NOTIFICATION-TYPE + OBJECTS { jnxFruContentsIndex, + jnxFruL1Index, + jnxFruL2Index, + jnxFruL3Index, + jnxFruName, + jnxFruType, + jnxFruSlot } + STATUS current + DESCRIPTION + "A ExtSrcLockAcquired trap signifies that the SNMP + entity, acting in an agent role, has detected that + a lock for an external clock source has been acquired." + ::= { jnxChassisOKTraps 5 } + + jnxHardDiskOK NOTIFICATION-TYPE + OBJECTS { jnxFruContentsIndex, + jnxFruL1Index, + jnxFruL2Index, + jnxFruL3Index, + jnxFruName, + jnxFruType, + jnxFruSlot } + STATUS current + DESCRIPTION + "A jnxHardDiskOK trap signifies that the SNMP + entity, acting in an agent role, has detected that + the Disk in the specified Routing Engine has + recovered from the failure condition." + ::= { jnxChassisOKTraps 6 } + + jnxPowerSupplyInputOK NOTIFICATION-TYPE + OBJECTS { jnxContentsContainerIndex, + jnxContentsL1Index, + jnxContentsL2Index, + jnxContentsL3Index, + jnxContentsDescr, + jnxOperatingState } + STATUS current + DESCRIPTION + "A jnxPowerSupplyInputOK trap signifies that the + SNMP entity, acting in an agent role, has detected + that the specified power supply's input feed in the + chassis has recovered from the failure condition." + ::= { jnxChassisOKTraps 7 } + +END |