Diffstat (limited to 'MIBS/junose/Juniper-ERX-System-MIB')
-rw-r--r--MIBS/junose/Juniper-ERX-System-MIB2031
1 files changed, 2031 insertions, 0 deletions
diff --git a/MIBS/junose/Juniper-ERX-System-MIB b/MIBS/junose/Juniper-ERX-System-MIB
new file mode 100644
index 0000000..9900b0f
--- /dev/null
+++ b/MIBS/junose/Juniper-ERX-System-MIB
@@ -0,0 +1,2031 @@
+
+-- *****************************************************************************
+-- Juniper-ERX-System-MIB
+--
+-- Juniper Networks Enterprise MIB
+-- ERX System MIB
+--
+-- Copyright (c) 1999 Redstone Communications, Inc.
+-- Copyright (c) 1999, 2002 Unisphere Networks, Inc.
+-- Copyright (c) 2002, 2003 Juniper Networks, Inc.
+-- All Rights Reserved.
+-- *****************************************************************************
+
+Juniper-ERX-System-MIB DEFINITIONS ::= BEGIN
+
+IMPORTS
+ MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Integer32, Unsigned32,
+ TimeTicks
+ FROM SNMPv2-SMI
+ TEXTUAL-CONVENTION, DisplayString, TruthValue, DateAndTime
+ FROM SNMPv2-TC
+ MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
+ FROM SNMPv2-CONF
+ InterfaceIndexOrZero
+ FROM IF-MIB
+ juniMibs
+ FROM Juniper-MIBs
+ JuniEnable
+ FROM Juniper-TC;
+
+juniERXSysMIB MODULE-IDENTITY
+ LAST-UPDATED "200311242101Z" -- 24-Nov-03 04:01 PM EST
+ ORGANIZATION "Juniper Networks, Inc."
+ CONTACT-INFO
+ " Juniper Networks, Inc.
+ Postal: 10 Technology Park Drive
+ Westford, MA 01886-3146
+ USA
+ Tel: +1 978 589 5800
+ Email: mib@Juniper.net"
+ DESCRIPTION
+ "Deprecated MIB objects for managing ERX Edge Router system elements.
+ See the generic E-series system MIB (Juniper-System-MIB) for the
+ preferred definitions. If both MIBs are supported, using the
+ corresponding varbinds from both MIBs to set the same object in a single
+ PDU is not supported."
+ -- Revision History
+ REVISION "200311242101Z" -- 24-Nov-03 04:01 PM EST - JUNOSe 5.3
+ DESCRIPTION
+ "Added Hybrid Line Modules and Hybrid IOA modules.
+ Added GE2 Line Module and GE2 IOA module. "
+ REVISION "200311241426Z" -- 24-Nov-03 09:26 AM EST - JUNOSe 5.0
+ DESCRIPTION
+ "Replaced Unisphere names with Juniper names."
+ REVISION "200311182206Z" -- 18-Nov-03 05:06 PM EST - JUNOSe 4.1
+ DESCRIPTION
+ "Deprecated this MIB in favor of the generic E-series system MIB,
+ Juniper-System-MIB.
+ Added a general trap control object.
+ Added new line card types: vts, oc48, ut3Atm4."
+ REVISION "200210141740Z" -- 14-Oct-02 01:40 PM EDT - JUNOSe 4.0
+ DESCRIPTION
+ "Added new line card types: X.21/V.35, Ut3f12, Ue3f12, Cocx-F3."
+ REVISION "200204122057Z" -- 12-Apr-02 04:57 PM EDT - JUNOSe 3.3
+ DESCRIPTION
+ "Modified the following objects:
+ juniERXSysTempFanStatus
+ juniERXSysTempStatus
+ Added the following objects:
+ juniERXSysTempProtectionStatus
+ juniERXSysTempProtectionHoldOffTime
+ juniERXSysTempProtectionHoldOffTimeRemaining
+ Added the following notification:
+ juniERXSysTempProtectionStatusChange "
+ REVISION "200105211927Z" -- 21-May-01 03:27 PM EDT - JUNOSe 3.2
+ DESCRIPTION
+ "Added the following objects:
+ juniERXSysMemUtilPct
+ juniERXSysMemCapacity
+ juniERXSysHighMemUtilThreshold
+ juniERXSysAbatedMemUtilThreshold
+ juniERXSysMemUtilTrapEnable
+ Added the following notifications:
+ juniERXSysHighMemUtil
+ juniERXSysAbatedMemUtil "
+ REVISION "200105151827Z" -- 15-May-01 02:27 PM EDT - JUNOSe 3.0
+ DESCRIPTION
+ "Added support for system timing parameters.
+ Added juniERXSysSlotDescr to juniERXSysSlotOperStatusChange trap."
+ REVISION "200004251844Z" -- 25-Apr-00 2:44 PM EDT - JUNOSe 2.0
+ DESCRIPTION
+ "Added board serial number, assembly number and assembly revision."
+ REVISION "200001200000Z" -- 20-Jan-00 - JUNOSe 1.3
+ DESCRIPTION
+ "Added OC-12 card and Dual FE card support.
+ Added redundancy/reversion and boot record configuration support."
+ REVISION "9902100000Z" -- 10-Feb-99 - JUNOSe 1.0
+ DESCRIPTION
+ "Initial version of this MIB module."
+ ::= { juniMibs 17 }
+
+
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+-- Textual conventions
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+JuniTimingSelector ::= TEXTUAL-CONVENTION
+ STATUS deprecated
+ DESCRIPTION
+ "The system timing selector.
+ A value of 1 corresponds to the primary timing selector.
+ A value of 2 corresponds to the secondary timing selector.
+ A value of 3 corresponds to the tertiary timing selector.
+ A value of 4 indicates an error with the timing selector."
+ SYNTAX Integer32 (1..4)
+
+JuniTimingSourceType ::= TEXTUAL-CONVENTION
+ STATUS deprecated
+ DESCRIPTION
+ "The set of selectable timing source types. The timing source type
+ determines the timing source parameters."
+ SYNTAX INTEGER {
+ timingInterfaceIfIndex(1),
+ timingInternal(2),
+ timingLine(3) }
+
+JuniTimingSourceLineType ::= TEXTUAL-CONVENTION
+ STATUS deprecated
+ DESCRIPTION
+ "The set of choices for line type timing."
+ SYNTAX INTEGER {
+ timingSourceLineUndefined(0),
+ timingSourceLineE1PortA(1), -- e1:a
+ -- External SC E1 line input, port A
+ timingSourceLineE1PortB(2), -- e1:b
+ -- External SC E1 line input, port B
+ timingSourceLineT1PortA(3), -- t1:a
+ -- External SC T1 line input, port A
+ timingSourceLineT1PortB(4) } -- t1:b
+ -- External SC T1 line input, port B
+
+JuniSysCardType ::= TEXTUAL-CONVENTION
+ STATUS deprecated
+ DESCRIPTION
+ "The type of card in a system slot:
+ unknown Unknown type.
+ srp Switch/Route Processor.
+ ct3 Channelized T3.
+ oc3 OC-3 (SONET/SDH).
+ ut3Atm Unchannelized T3 (ATM service).
+ ut3Frame Unchannelized T3 (Frame service).
+ ue3Atm Unchannelized E3 (ATM service).
+ ue3Frame Uncahnnelized E3 (Frame service).
+ ce1 Channelized E1.
+ ct1 Channelized T1.
+ dpfe Dual Port Fast Ethernet.
+ oc12Pos OC-12 (POS/SDH).
+ oc12Atm OC-12 (ATM service).
+ oc3Pos Quad OC-3 (POS/SDH).
+ oc3Atm Quad OC-3 (ATM service).
+ ge Gigabit Ethernet.
+ fe8 Fast Ethernet 8-port.
+ oc3oc12Pos Generic OC3/OC12 POS (multi-personality).
+ oc3oc12Atm Generic OC3/OC12 ATM (multi-personality).
+ coc3oc12 Channelized generic OC3/OC12 (multi-personality).
+ coc3 Channelized OC3.
+ coc12 Channelized OC12.
+ oc12Server OC-12 Rate Server Card.
+ hssi High Speed Serial Interface.
+ geFe Generic GE/FE (multi-personality).
+ ct3P12 Channelized T3 12-port.
+ v35 X.21/V.35 Card.
+ ut3f12 Unchannelized T3 12-port.
+ ue3f12 Unchannelized E3 12-port.
+ coc3F3 OC-3 channelized to T3.
+ coc12F3 OC-12 channelized to T3.
+ cocxF3 12-port T3/E3 or OC3/OC12 (multi-personality).
+ vts Virtual Tunnel Server.
+ oc48 OC-48 (SONET/SDH).
+ ut3Atm4 4-port Unchannelized T3 ATM.
+ hybrid Generic ATM/POS/GE Hybrid (multi-personality).
+ oc3AtmGe OC3 ATM 2-port Gigabit Ethernet 1-port.
+ oc3AtmPos OC3 ATM 2-port OC3 POS 2-port.
+ ge2 Gigabit Ethernet 2-port."
+ SYNTAX INTEGER {
+ unknown(0),
+ srp(1),
+ ct3(2),
+ oc3(3),
+ ut3Atm(4),
+ ut3Frame(5),
+ ue3Atm(6),
+ ue3Frame(7),
+ ce1(8),
+ ct1(9),
+ dpfe(10),
+ oc12Pos(11),
+ oc12Atm(12),
+ oc3Pos(13),
+ oc3Atm(14),
+ ge(15),
+ fe8(16),
+ oc3oc12Pos(17),
+ oc3oc12Atm(18),
+ coc3oc12(19),
+ coc3(20),
+ coc12(21),
+ oc12Server(22),
+ hssi(23),
+ geFe(24),
+ ct3P12(25),
+ v35(26),
+ ut3f12(27),
+ ue3f12(28),
+ coc12F3(29),
+ coc3F3(30),
+ cocxF3(31),
+ vts(32),
+ oc48(33),
+ ut3Atm4(34),
+ hybrid(35),
+ oc3AtmGe(36),
+ oc3AtmPos(37),
+ ge2(38) }
+
+
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+-- MIB Structure
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+juniERXSysTrap OBJECT IDENTIFIER ::= { juniERXSysMIB 0 }
+juniERXSysObjects OBJECT IDENTIFIER ::= { juniERXSysMIB 1 }
+juniERXSysConformance OBJECT IDENTIFIER ::= { juniERXSysMIB 2 }
+
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+-- Managed objects
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+--
+-- Object Groups
+--
+juniERXSysGeneral OBJECT IDENTIFIER ::= { juniERXSysObjects 1 }
+juniERXSysFabric OBJECT IDENTIFIER ::= { juniERXSysObjects 2 }
+juniERXSysNvs OBJECT IDENTIFIER ::= { juniERXSysObjects 3 }
+juniERXSysSlot OBJECT IDENTIFIER ::= { juniERXSysObjects 4 }
+juniERXSysPort OBJECT IDENTIFIER ::= { juniERXSysObjects 5 }
+juniERXSysPower OBJECT IDENTIFIER ::= { juniERXSysObjects 6 }
+juniERXSysTemperature OBJECT IDENTIFIER ::= { juniERXSysObjects 7 }
+juniERXSysSubsystem OBJECT IDENTIFIER ::= { juniERXSysObjects 8 }
+
+
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+--
+-- Chassis objects
+--
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+juniERXSysChassisRev OBJECT-TYPE
+ SYNTAX Integer32 (0..255)
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "Chassis revision number. If unknown, the value 255 is reported."
+ ::= { juniERXSysGeneral 1 }
+
+juniERXSysSwVersion OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "Currently executing operational software version."
+ ::= { juniERXSysGeneral 2 }
+
+juniERXSysSwBuildDate OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "Build date of currently executing operational software version."
+ ::= { juniERXSysGeneral 3 }
+
+juniERXSysRevertControl OBJECT-TYPE
+ SYNTAX INTEGER {
+ off(0),
+ immediate(1),
+ timeOfDay(2) }
+ MAX-ACCESS read-write
+ STATUS deprecated
+ DESCRIPTION
+ "Global revert control:
+ off Disable global revert.
+ immediate All slots are to revert immediately (asap).
+ timeOfDay All slots are to revert at time specified by
+ juniRxSysRevertTimeOfDay. This object/value must
+ be set concurrently with juniERXSysRevertTimeOfDay."
+ ::= { juniERXSysGeneral 4 }
+
+juniERXSysRevertTimeOfDay OBJECT-TYPE
+ SYNTAX Integer32 (0..86399)
+ UNITS "seconds"
+ MAX-ACCESS read-write
+ STATUS deprecated
+ DESCRIPTION
+ "The number of seconds past midnight on any given day at which time
+ reverts are allowed to occur. This object must be set concurrently with
+ juniERXSysRevertControl."
+ ::= { juniERXSysGeneral 5 }
+
+juniERXSysBootConfigControl OBJECT-TYPE
+ SYNTAX INTEGER {
+ file(0),
+ fileOnce(1),
+ factoryDefaults(2),
+ runningConfiguration(3) }
+ MAX-ACCESS read-write
+ STATUS deprecated
+ DESCRIPTION
+ "System boot configuration control:
+ file Revert to configuration settings specified by
+ juniERXSysBootConfigFile. The
+ juniERXSysBootConfigControl and
+ juniERXSysBootConfigFile must be specified
+ together in the same set request PDU.
+ fileOnce Revert to configuration settings specified by
+ juniERXSysBootConfigFile. Do not continue to
+ use file after using it once. The
+ juniERXSysBootConfigControl and
+ juniERXSysBootConfigFile must be specified
+ together in the same set request PDU.
+ factoryDefaults Revert to factory default settings.
+ runningConfiguration Revert to current settings."
+ ::= { juniERXSysGeneral 6 }
+
+juniERXSysBootBackupConfigControl OBJECT-TYPE
+ SYNTAX INTEGER {
+ file(0),
+ factoryDefaults(1),
+ none(2) }
+ MAX-ACCESS read-write
+ STATUS deprecated
+ DESCRIPTION
+ "System boot backup configuration control:
+ file Revert to backup configuration settings
+ specified by juniERXSysBootBackupConfigFile.
+ The juniERXSysBootBackupConfigControl and
+ juniERXSysBootBackupConfigFile must be
+ specified together in the same set request
+ PDU.
+ factoryDefaults Revert to factory default settings.
+ none Specify no backup."
+ ::= { juniERXSysGeneral 7 }
+
+juniERXSysBootForceBackupControl OBJECT-TYPE
+ SYNTAX INTEGER {
+ off(0),
+ on(1) }
+ MAX-ACCESS read-write
+ STATUS deprecated
+ DESCRIPTION
+ "System boot force backup control:
+ off Do not force revert to backup settings.
+ on Do force revert to backup settings."
+ ::= { juniERXSysGeneral 8 }
+
+juniERXSysBootAutoRevertControl OBJECT-TYPE
+ SYNTAX INTEGER {
+ default(0),
+ never(1),
+ set(2) }
+ MAX-ACCESS read-write
+ STATUS deprecated
+ DESCRIPTION
+ "System boot auto revert control:
+ default Use default auto-revert tolerances.
+ never Never auto-revert to backup.
+ set Set auto-revert settings at specified tolerances."
+ ::= { juniERXSysGeneral 9 }
+
+juniERXSysBootAutoRevertCountTolerance OBJECT-TYPE
+ SYNTAX Unsigned32 (0..4294967294)
+ MAX-ACCESS read-write
+ STATUS deprecated
+ DESCRIPTION
+ "The auto-revert reboot count tolerance. This object cannot be set to
+ zero, but may contain a zero value when the control is set to never(1)."
+ ::= { juniERXSysGeneral 10 }
+
+juniERXSysBootAutoRevertTimeTolerance OBJECT-TYPE
+ SYNTAX Unsigned32 (0..4294967294)
+ UNITS "seconds"
+ MAX-ACCESS read-write
+ STATUS deprecated
+ DESCRIPTION
+ "The auto-revert reboot time tolerance. This object cannot be set to
+ zero, but will contain a zero value when the control is set to
+ never(1)."
+ ::= { juniERXSysGeneral 11 }
+
+juniERXSysBootReleaseFile OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..128))
+ MAX-ACCESS read-write
+ STATUS deprecated
+ DESCRIPTION
+ "The local boot release file name, with extension .rel."
+ DEFVAL { "" }
+ ::= { juniERXSysGeneral 12 }
+
+juniERXSysBootConfigFile OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..128))
+ MAX-ACCESS read-write
+ STATUS deprecated
+ DESCRIPTION
+ "The local boot configuration file name, with extension .cnf. The
+ juniERXSysBootConfigControl and juniERXSysBootConfigFile must be
+ specified together in the same set request PDU."
+ DEFVAL { "" }
+ ::= { juniERXSysGeneral 13 }
+
+juniERXSysBootBackupReleaseFile OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..128))
+ MAX-ACCESS read-write
+ STATUS deprecated
+ DESCRIPTION
+ "The local backup boot release file name, with extension .rel."
+ DEFVAL { "" }
+ ::= { juniERXSysGeneral 14 }
+
+juniERXSysBootBackupConfigFile OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..128))
+ MAX-ACCESS read-write
+ STATUS deprecated
+ DESCRIPTION
+ "The local backup boot configuration file name, with extension .cnf.
+ The juniERXSysBootBackupConfigControl and juniERXSysBootBackupConfigFile
+ must be specified together in the same set request PDU."
+ DEFVAL { "" }
+ ::= { juniERXSysGeneral 15 }
+
+juniERXSysAdminTimingSource OBJECT-TYPE
+ SYNTAX JuniTimingSelector
+ MAX-ACCESS read-write
+ STATUS deprecated
+ DESCRIPTION
+ "The administrative timing source for the ERX system. The ERX
+ periodically monitors the status of three timing sources, primary,
+ secondary and tertiary. If the systems current timing source fails, the
+ system will automatically downgrade to the next timing source. If the
+ system is configured to automatically upgrade
+ (juniERXSysTimingDisableAutoUpgrade is set to false(2)) the system will
+ switch back to the higher timing source when it becomes available.
+
+ A timing source failure can be detected by comparing the operational and
+ admin timing sources. If they are not equal, the system has swapped
+ timing sources because the administratively set value is in the error
+ state."
+ ::= { juniERXSysGeneral 16 }
+
+juniERXSysOperTimingSource OBJECT-TYPE
+ SYNTAX JuniTimingSelector
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "The operations timing source for the ERX system. The ERX periodically
+ monitors the status of three timing sources, primary, secondary and
+ tertiary. If the systems current timing source fails, the system will
+ automatically downgrade to the next timing source. If the system is
+ configured to automatically upgrade (juniERXSysTimingDisableAutoUpgrade
+ is set to false(2)) the system will switch back to the higher timing
+ source when it becomes available."
+ ::= { juniERXSysGeneral 17 }
+
+juniERXSysTimingDisableAutoUpgrade OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS deprecated
+ DESCRIPTION
+ "This object controls the automatic timing selector upgrade. Setting
+ this object to true(1) will prevent automatic upgrade to the next
+ highest timing selector. Setting this object to false(2) will enable
+ the automatic upgrade of timing selectors."
+ DEFVAL { false }
+ ::= { juniERXSysGeneral 18 }
+
+juniERXSysTimingSelectorTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF JuniERXSysTimingSelectorEntry
+ MAX-ACCESS not-accessible
+ STATUS deprecated
+ DESCRIPTION
+ "Table of system timing selectors."
+ ::= { juniERXSysGeneral 19 }
+
+juniERXSysTimingSelectorEntry OBJECT-TYPE
+ SYNTAX JuniERXSysTimingSelectorEntry
+ MAX-ACCESS not-accessible
+ STATUS deprecated
+ DESCRIPTION
+ "A table entry describing a system timing selector."
+ INDEX { juniERXSysTimingSelectorIndex }
+ ::= { juniERXSysTimingSelectorTable 1 }
+
+JuniERXSysTimingSelectorEntry ::= SEQUENCE {
+ juniERXSysTimingSelectorIndex JuniTimingSelector,
+ juniERXSysTimingSourceType JuniTimingSourceType,
+ juniERXSysTimingSourceIfIndex InterfaceIndexOrZero,
+ juniERXSysTimingSourceLine JuniTimingSourceLineType,
+ juniERXSysTimingStatus INTEGER }
+
+juniERXSysTimingSelectorIndex OBJECT-TYPE
+ SYNTAX JuniTimingSelector
+ MAX-ACCESS not-accessible
+ STATUS deprecated
+ DESCRIPTION
+ "The system timing selector index associated with this entry."
+ ::= { juniERXSysTimingSelectorEntry 1 }
+
+juniERXSysTimingSourceType OBJECT-TYPE
+ SYNTAX JuniTimingSourceType
+ MAX-ACCESS read-write
+ STATUS deprecated
+ DESCRIPTION
+ "The system timing source type for this entry. This object must be
+ present when setting either the juniERXSysTimingSourceIfIndex or
+ juniERXSysTimingSourceLine objects. Also, if the value of this object
+ is set to timingInternal(2), no other objects should be simultanously
+ set, otherwise the agent will return an error."
+ ::= { juniERXSysTimingSelectorEntry 2 }
+
+juniERXSysTimingSourceIfIndex OBJECT-TYPE
+ SYNTAX InterfaceIndexOrZero
+ MAX-ACCESS read-write
+ STATUS deprecated
+ DESCRIPTION
+ "The ifIndex of the interface selected as the system timing source. The
+ juniERXSysTimingSourceType object must be set to
+ timingInterfaceIfIndex(1) otherwise setting this object will fail."
+ ::= { juniERXSysTimingSelectorEntry 3 }
+
+juniERXSysTimingSourceLine OBJECT-TYPE
+ SYNTAX JuniTimingSourceLineType
+ MAX-ACCESS read-write
+ STATUS deprecated
+ DESCRIPTION
+ "The line type timing source for this entry. The
+ juniRxSysTimingSourceType object must be set to timingLine(3) for the
+ agent to accept a set to this object."
+ DEFVAL { timingSourceLineUndefined }
+ ::= { juniERXSysTimingSelectorEntry 4 }
+
+juniERXSysTimingStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ timingStatusOk(1),
+ timingStatusError(2),
+ timingStatusUnknown(3) }
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "The status associated with this system timing selector."
+ ::= { juniERXSysTimingSelectorEntry 5 }
+
+juniERXSysMemUtilPct OBJECT-TYPE
+ SYNTAX Integer32 (-1..100)
+ UNITS "percent"
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "Percentage of system memory utilization. A value of -1 indicates the
+ utilization is unknown."
+ ::= { juniERXSysGeneral 20 }
+
+juniERXSysMemCapacity OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "bytes"
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "The total memory capacity of the system. Negative values are returned
+ when the capacity exceeds 2147483647; interpret the negative 32-bit
+ integer as an unsigned 32-bit integer value."
+ ::= { juniERXSysGeneral 21 }
+
+juniERXSysHighMemUtilThreshold OBJECT-TYPE
+ SYNTAX Integer32 (1..100)
+ UNITS "percent"
+ MAX-ACCESS read-write
+ STATUS deprecated
+ DESCRIPTION
+ "The value of system memory utilization, where if reached for the first
+ time will generate a high memory utilization event to the management
+ entity on this system.
+
+ The value of this object must be greated than the value of
+ juniERXSysAbatedMemUtilThreshold."
+ DEFVAL { 85 }
+ ::= { juniERXSysGeneral 22 }
+
+juniERXSysAbatedMemUtilThreshold OBJECT-TYPE
+ SYNTAX Integer32 (0..99)
+ UNITS "percent"
+ MAX-ACCESS read-write
+ STATUS deprecated
+ DESCRIPTION
+ "The value of system memory utilization that is used to determine when
+ to generate an abated memory utilization event notification to the
+ management entity on this system.
+
+ The value of this object must be less than the value of
+ juniERXSysHighMemUtilThreshold.
+
+ The abated memory utilization trap is sent once if the high memory
+ threshold was reached, and memory utilization falls to the value of this
+ object."
+ DEFVAL { 75 }
+ ::= { juniERXSysGeneral 23 }
+
+juniERXSysMemUtilTrapEnable OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS deprecated
+ DESCRIPTION
+ "Controls the sending of system memory utilization events. Setting the
+ value of this object to true(1) will cause system memory utilization
+ event notification, if they occur, to be sent to the management entity
+ on this system. Setting the value of this object to false(2) will
+ disable event notifications."
+ DEFVAL { false }
+ ::= { juniERXSysGeneral 24 }
+
+juniERXSysGeneralTrapEnable OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS deprecated
+ DESCRIPTION
+ "Controls whether a member of the set of ERX system notifications
+ (traps) defined in this MIB or the counterpart notifications defined in
+ the generic E-series system MIB (Juniper-System-MIB) will be initiated
+ when the appropriate system event occures. Setting the value of this
+ object to true(1) will enable the event notifications from this MIB, if
+ they occur, to be sent to the management entity on this system, provided
+ no other restrictions are in effect, instead of the counterparts from
+ the generic system MIB. Setting the value of this object to false(2)
+ will disable all event notifications defined in this MIB, enabling the
+ ones from the generic system MIB."
+ DEFVAL { false }
+ ::= { juniERXSysGeneral 25 }
+
+
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+--
+-- Fabric objects
+--
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+juniERXSysFabricSpeed OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "gigabits per second"
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "Speed of switching fabric, in gigabits per second."
+ ::= { juniERXSysFabric 1 }
+
+juniERXSysFabricRev OBJECT-TYPE
+ SYNTAX Integer32 (0..255)
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "Fabric revision number. If unknown, the value 255 is reported."
+ ::= { juniERXSysFabric 2 }
+
+
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+--
+-- Nvs objects
+--
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+juniERXSysNvsStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ notPresent(0),
+ writeProtected(1),
+ volumeError(2),
+ nearCapacity(3),
+ ok(4),
+ nearConfigCapacity(5) }
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "Status of non-volatile storage (NVS):
+ notPresent NVS is not installed.
+ writeProtected NVS is write-protected.
+ volumeError Status poll of NVS failed.
+ nearCapacity Utilization exceeds 85% of NVS capacity.
+ ok NVS is operational, none of the preceding
+ conditions apply.
+ nearConfigCapacity Utilization exceeds the ability to save the
+ running configuration."
+ ::= { juniERXSysNvs 1 }
+
+juniERXSysNvsCapacity OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "megabytes"
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "Capacity of NVS storage in megabytes."
+ ::= { juniERXSysNvs 2 }
+
+juniERXSysNvsUtilPct OBJECT-TYPE
+ SYNTAX Integer32 (-1..100)
+ UNITS "percent"
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "Percentage of NVS storage used. A value of -1 indicates NVS
+ utilization is unknown."
+ ::= { juniERXSysNvs 3 }
+
+
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+--
+-- Slot objects
+--
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+juniERXSysSlotCount OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "The number of slots in the system."
+ ::= { juniERXSysSlot 1 }
+
+juniERXSysSlotTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF JuniERXSysSlotEntry
+ MAX-ACCESS not-accessible
+ STATUS deprecated
+ DESCRIPTION
+ "Table of system slots."
+ ::= { juniERXSysSlot 2 }
+
+juniERXSysSlotEntry OBJECT-TYPE
+ SYNTAX JuniERXSysSlotEntry
+ MAX-ACCESS not-accessible
+ STATUS deprecated
+ DESCRIPTION
+ "A table entry describing contents of a system slot."
+ INDEX { juniERXSysSlotIndex }
+ ::= { juniERXSysSlotTable 1 }
+
+JuniERXSysSlotEntry ::= SEQUENCE {
+ juniERXSysSlotIndex Integer32,
+ juniERXSysSlotDescr DisplayString,
+ juniERXSysSlotCurrentCardType JuniSysCardType,
+ juniERXSysSlotRev Integer32,
+ juniERXSysSlotAdminStatus JuniEnable,
+ juniERXSysSlotOperStatus INTEGER,
+ juniERXSysSlotDisableReason INTEGER,
+ juniERXSysSlotExpectedCardType JuniSysCardType,
+ juniERXSysSlotControl INTEGER,
+ juniERXSysSlotCpuUtilPct Integer32,
+ juniERXSysSlotMemUtilPct Integer32,
+ juniERXSysSlotIoaPresent TruthValue,
+ juniERXSysSlotPortCount Integer32,
+ juniERXSysSlotLastChange TimeTicks,
+ juniERXSysSlotRedundancyLockout JuniEnable,
+ juniERXSysSlotRedundancyGroupId Unsigned32,
+ juniERXSysSlotSpareServer TruthValue,
+ juniERXSysSlotAssociatedSlot Integer32,
+ juniERXSysSlotRevertControl INTEGER,
+ juniERXSysSlotRedundancyRevertTime DateAndTime,
+ juniERXSysSlotBootReleaseFile DisplayString,
+ juniERXSysSlotBootBackupReleaseFile DisplayString,
+ juniERXSysSlotSerialNumber DisplayString,
+ juniERXSysSlotAssemblyPartNumber DisplayString,
+ juniERXSysSlotAssemblyRev DisplayString,
+ juniERXSysSlotIoaSerialNumber DisplayString,
+ juniERXSysSlotIoaAssemblyPartNumber DisplayString,
+ juniERXSysSlotIoaAssemblyRev DisplayString }
+
+juniERXSysSlotIndex OBJECT-TYPE
+ SYNTAX Integer32 (0..255)
+ MAX-ACCESS not-accessible
+ STATUS deprecated
+ DESCRIPTION
+ "Slot number.
+
+ NOTE: Slot numbers are zero-based."
+ ::= { juniERXSysSlotEntry 1 }
+
+juniERXSysSlotDescr OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..63))
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "Textual description of the card."
+ ::= { juniERXSysSlotEntry 2 }
+
+juniERXSysSlotCurrentCardType OBJECT-TYPE
+ SYNTAX JuniSysCardType
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "Type of card actually in the slot. This could be different from the
+ type reported in juniERXSysSlotExpectedCardType, in which case it may be
+ necessary to set juniERXSysSlotControl to 'flush' before this card can
+ be made operational."
+ ::= { juniERXSysSlotEntry 3 }
+
+juniERXSysSlotRev OBJECT-TYPE
+ SYNTAX Integer32 (0..255)
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "Revision number of the card. If unknown, the value 255 is reported."
+ ::= { juniERXSysSlotEntry 4 }
+
+juniERXSysSlotAdminStatus OBJECT-TYPE
+ SYNTAX JuniEnable
+ MAX-ACCESS read-write
+ STATUS deprecated
+ DESCRIPTION
+ "Exerts administrative control to enable/disable the slot."
+ ::= { juniERXSysSlotEntry 5 }
+
+juniERXSysSlotOperStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(0),
+ empty(1),
+ disabled(2),
+ failed(3),
+ booting(4),
+ initializing(5),
+ online(6),
+ standby(7),
+ inactive(8) }
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "Status of the card."
+ ::= { juniERXSysSlotEntry 6 }
+
+juniERXSysSlotDisableReason OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(0),
+ unknown(1),
+ assessing(2),
+ admin(3),
+ cardMismatch(4),
+ fabricLimit(5),
+ imageError(6) }
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "Indicates the condition causing the slot to be disabled:
+ none Value when card is not disabled.
+ unknown Unknown reason for disablement.
+ assessing The slot content is being assessed (transient
+ initialization state).
+ admin The slot is administratively disabled.
+ cardMismatch The current card type conflicts with configuration
+ associated with a different card type that
+ previously occupied the slot.
+ fabricLimit Card resource requirements exceed available fabric
+ capacity.
+ imageError Software image for card is missing or invalid."
+ ::= { juniERXSysSlotEntry 7 }
+
+juniERXSysSlotExpectedCardType OBJECT-TYPE
+ SYNTAX JuniSysCardType
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "Type of card associated with this slot through prior presence. After
+ the card is removed, this association persists (and inhibits operation
+ of a different card type in this slot, if one is inserted) until
+ juniERXSysSlotControl is set to 'flush'."
+ ::= { juniERXSysSlotEntry 8 }
+
+juniERXSysSlotControl OBJECT-TYPE
+ SYNTAX INTEGER {
+ noOperation(0),
+ flush(1),
+ reset(2),
+ forceFailover(3),
+ noBoot(4),
+ noBootBackup(5) }
+ MAX-ACCESS read-write
+ STATUS deprecated
+ DESCRIPTION
+ "Administrative control of this slot:
+ noOperation Setting this value has no effect.
+ flush Flushes configuration associated with a
+ card type that previously occupied this slot.
+ Used to explicitly confirm that the slot is
+ now empty, or contains a different card type.
+ Card must be disabled when this value is asserted.
+ See description for juniERXSysSlotDisableReason.
+ reset Resets the slot.
+ forceFailover Forces the slot to failover to backup.
+ noBoot Deconfigure primary release file for the slot.
+ noBootBackup Deconfigure backup release file for the slot."
+ ::= { juniERXSysSlotEntry 9 }
+
+juniERXSysSlotCpuUtilPct OBJECT-TYPE
+ SYNTAX Integer32 (-1..100)
+ UNITS "percent"
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "Percentage of CPU utilization. A value of -1 indicates the utilization
+ is unknown."
+ ::= { juniERXSysSlotEntry 10 }
+
+juniERXSysSlotMemUtilPct OBJECT-TYPE
+ SYNTAX Integer32 (-1..100)
+ UNITS "percent"
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "Percentage of memory utilization. A value of -1 indicates the
+ utilization is unknown."
+ ::= { juniERXSysSlotEntry 11 }
+
+juniERXSysSlotIoaPresent OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "Indicates whether the card's corresponding I/O adapter is present."
+ ::= { juniERXSysSlotEntry 12 }
+
+juniERXSysSlotPortCount OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "Number of physical ports for the EXPECTED card type for this slot.
+
+ NOTE: In event of a card mismatch in this slot, the port count for the
+ CURRENT card in this slot is not recognized/reported until the
+ configuration for the EXPECTED card is explicitly flushed via
+ juniERXSysSlotControl."
+ ::= { juniERXSysSlotEntry 13 }
+
+juniERXSysSlotLastChange OBJECT-TYPE
+ SYNTAX TimeTicks
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "The value of sysUpTime when the value of juniERXSysSlotOperStatus
+ last changed."
+ ::= { juniERXSysSlotEntry 14 }
+
+juniERXSysSlotRedundancyLockout OBJECT-TYPE
+ SYNTAX JuniEnable
+ MAX-ACCESS read-write
+ STATUS deprecated
+ DESCRIPTION
+ "Exerts administrative control to enable/disable Redundancy protection
+ for the slot."
+ ::= { juniERXSysSlotEntry 15 }
+
+juniERXSysSlotRedundancyGroupId OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "Identifies the Redundancy group as derived from hardware settings."
+ ::= { juniERXSysSlotEntry 16 }
+
+juniERXSysSlotSpareServer OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "True only if the line card in slot is a spare redundant server."
+ ::= { juniERXSysSlotEntry 17 }
+
+juniERXSysSlotAssociatedSlot OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "If the module is a primary card and the spare is acting on its behalf,
+ then the value of this object is the slot number of the associated
+ spare.
+
+ If the module is a primary card and is active (not spared), then the
+ value of this object is the cards actual slot number.
+
+ If the module is a spare card and it is active, then the value of this
+ object is the slot number of the primary card that is being spared for.
+
+ If the module is a spare and it is inactive, then the value of this
+ object is the its own slot number.
+
+ If module is not part of a redundancy group, or the slot is empty, the
+ value of this object is 255."
+ ::= { juniERXSysSlotEntry 18 }
+
+juniERXSysSlotRevertControl OBJECT-TYPE
+ SYNTAX INTEGER {
+ off(0),
+ immediate(1),
+ timeAndDate(2) }
+ MAX-ACCESS read-write
+ STATUS deprecated
+ DESCRIPTION
+ "Per-slot revert control:
+ off Disable slot revert.
+ immediate Slot is to revert immediately (asap).
+ timeAndDate Slot is to revert at time specified by
+ juniRxSysSlotRedundancyRevertTime."
+ ::= { juniERXSysSlotEntry 19 }
+
+juniERXSysSlotRedundancyRevertTime OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-write
+ STATUS deprecated
+ DESCRIPTION
+ "The date and time associated with the timeAndDate (delayed) revert
+ operation."
+ ::= { juniERXSysSlotEntry 20 }
+
+juniERXSysSlotBootReleaseFile OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..128))
+ MAX-ACCESS read-write
+ STATUS deprecated
+ DESCRIPTION
+ "The local boot release file name for this slot, with extension .rel."
+ DEFVAL { "" }
+ ::= { juniERXSysSlotEntry 21 }
+
+juniERXSysSlotBootBackupReleaseFile OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..128))
+ MAX-ACCESS read-write
+ STATUS deprecated
+ DESCRIPTION
+ "The local backup boot release file name for this slot, with extension
+ .rel."
+ DEFVAL { "" }
+ ::= { juniERXSysSlotEntry 22 }
+
+juniERXSysSlotSerialNumber OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..10))
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "The serial number of the card in this slot."
+ DEFVAL { "" }
+ ::= { juniERXSysSlotEntry 23 }
+
+juniERXSysSlotAssemblyPartNumber OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..10))
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "The part number of the card in this slot."
+ DEFVAL { "" }
+ ::= { juniERXSysSlotEntry 24 }
+
+juniERXSysSlotAssemblyRev OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..3))
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "The revision number of the card assembly in this slot."
+ DEFVAL { "" }
+ ::= { juniERXSysSlotEntry 25 }
+
+juniERXSysSlotIoaSerialNumber OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..10))
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "The serial number of the I/O adaptor on the card in this slot."
+ DEFVAL { "" }
+ ::= { juniERXSysSlotEntry 26 }
+
+juniERXSysSlotIoaAssemblyPartNumber OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..10))
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "The part number of the I/O adaptor on the card in this slot."
+ DEFVAL { "" }
+ ::= { juniERXSysSlotEntry 27 }
+
+juniERXSysSlotIoaAssemblyRev OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..3))
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "The revision number of the I/O adaptor assembly on the card in this
+ slot."
+ DEFVAL { "" }
+ ::= { juniERXSysSlotEntry 28 }
+
+
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+--
+-- System Port objects
+--
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+juniERXSysPortTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF JuniERXSysPortEntry
+ MAX-ACCESS not-accessible
+ STATUS deprecated
+ DESCRIPTION
+ "Table of system physical ports.
+
+ The information in this table reflects the ports for the EXPECTED card
+ type in each slot; in event of a card mismatch, this table permits
+ navigation of the existing configuration of the expected card type."
+ ::= { juniERXSysPort 1 }
+
+juniERXSysPortEntry OBJECT-TYPE
+ SYNTAX JuniERXSysPortEntry
+ MAX-ACCESS not-accessible
+ STATUS deprecated
+ DESCRIPTION
+ "A table entry describing a physical port of the system."
+ INDEX { juniERXSysSlotIndex,
+ juniERXSysPortIndex }
+ ::= { juniERXSysPortTable 1 }
+
+JuniERXSysPortEntry ::= SEQUENCE {
+ juniERXSysPortIndex Integer32,
+ juniERXSysPortDescr DisplayString,
+ juniERXSysPortType INTEGER,
+ juniERXSysPortIfIndex InterfaceIndexOrZero }
+
+juniERXSysPortIndex OBJECT-TYPE
+ SYNTAX Integer32 (0..255)
+ MAX-ACCESS not-accessible
+ STATUS deprecated
+ DESCRIPTION
+ "Port number of this physical port, relative to the slot in which it
+ resides. Each physical port is uniquely distinguished by its slot/port
+ pair.
+
+ NOTE: Port numbers are zero-based."
+ ::= { juniERXSysPortEntry 1 }
+
+juniERXSysPortDescr OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..63))
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "Textual description of this port."
+ ::= { juniERXSysPortEntry 2 }
+
+juniERXSysPortType OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(0),
+ eth(1),
+ ct3(2),
+ oc3c(3),
+ ut3Atm(4),
+ ut3Frame(5),
+ ue3Atm(6),
+ ue3Frame(7),
+ ce1(8),
+ ct1(9),
+ oc12cPos(10),
+ oc12cAtm(11),
+ oc3cPos(12),
+ oc3cAtm(13),
+ coc3(14),
+ coc12(15),
+ server(16),
+ hssi(17),
+ v35(18),
+ oc48cPos(19) }
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "Type of the physical port:
+ unknown Unknown port type.
+ eth Ethernet.
+ ct3 Channelized T3.
+ oc3c OC-3c (SONET/SDH).
+ ut3Atm Unchannelized T3 (ATM service).
+ ut3Frame Unchannelized T3 (Frame service).
+ ue3Atm Unchannelized E3 (ATM service).
+ ue3Frame Unchannelized E3 (Frame service).
+ ce1 Channelized E1.
+ ct1 Channelized T1.
+ oc12cPos OC-12c (POS/SDH).
+ oc12cAtm OC-12c (ATM service).
+ oc3cPos OC-3c (POS/SDH).
+ oc3cAtm OC-3c (ATM service).
+ coc3 Channelized OC-3.
+ coc12 Channelized OC-12.
+ server Tunnel Server (no physical ports).
+ hssi High Speed Serial Interface.
+ v35 X.21/V.35.
+ oc48cPos OC-48c (POS/SDH)."
+ ::= { juniERXSysPortEntry 3 }
+
+juniERXSysPortIfIndex OBJECT-TYPE
+ SYNTAX InterfaceIndexOrZero
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "The ifIndex of the Interfaces MIB ifTable entry corresponding to this
+ physical port; if zero, the ifIndex is unknown or does not exist."
+ ::= { juniERXSysPortEntry 4 }
+
+
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+--
+-- System Power objects
+--
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+juniERXSysPowerTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF JuniERXSysPowerEntry
+ MAX-ACCESS not-accessible
+ STATUS deprecated
+ DESCRIPTION
+ "Table of system power elements."
+ ::= { juniERXSysPower 1 }
+
+juniERXSysPowerEntry OBJECT-TYPE
+ SYNTAX JuniERXSysPowerEntry
+ MAX-ACCESS not-accessible
+ STATUS deprecated
+ DESCRIPTION
+ "A table entry describing status of a system power element."
+ INDEX { juniERXSysPowerIndex }
+ ::= { juniERXSysPowerTable 1 }
+
+JuniERXSysPowerEntry ::= SEQUENCE {
+ juniERXSysPowerIndex Integer32,
+ juniERXSysPowerDescr DisplayString,
+ juniERXSysPowerStatus INTEGER }
+
+juniERXSysPowerIndex OBJECT-TYPE
+ SYNTAX Integer32 (0..255)
+ MAX-ACCESS not-accessible
+ STATUS deprecated
+ DESCRIPTION
+ "Arbitrary integer index to distinguish entries in this table."
+ ::= { juniERXSysPowerEntry 1 }
+
+juniERXSysPowerDescr OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..63))
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "Textual description of this power element."
+ ::= { juniERXSysPowerEntry 2 }
+
+juniERXSysPowerStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ inactive(0),
+ active(1) }
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "The status of the power element:
+ inactive No power available from this element.
+ active Power available from this element."
+ ::= { juniERXSysPowerEntry 3 }
+
+
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+--
+-- System Temp objects
+--
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+juniERXSysTempFanStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ failed(0),
+ ok(1),
+ warning(2) }
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "Status of fan subsystem.
+ ok All components operational
+ warning The fan subsystem has a non-critical failure.
+ failed The fan subsystem has a critical failure, or has been
+ removed, and is now non-operational."
+ ::= { juniERXSysTemperature 1 }
+
+
+juniERXSysTempTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF JuniERXSysTempEntry
+ MAX-ACCESS not-accessible
+ STATUS deprecated
+ DESCRIPTION
+ "Table of system temperature sensors.
+
+ Sensors are distributed across the chassis, at least one sensor per
+ populated slot."
+ ::= { juniERXSysTemperature 2 }
+
+juniERXSysTempEntry OBJECT-TYPE
+ SYNTAX JuniERXSysTempEntry
+ MAX-ACCESS not-accessible
+ STATUS deprecated
+ DESCRIPTION
+ "A table entry describing status of a temperature sensor."
+ INDEX { juniERXSysSlotIndex,
+ juniERXSysTempIndex }
+ ::= { juniERXSysTempTable 1 }
+
+JuniERXSysTempEntry ::= SEQUENCE {
+ juniERXSysTempIndex Integer32,
+ juniERXSysTempDescr DisplayString,
+ juniERXSysTempStatus INTEGER,
+ juniERXSysTempValue Integer32 }
+
+juniERXSysTempIndex OBJECT-TYPE
+ SYNTAX Integer32 (0..255)
+ MAX-ACCESS not-accessible
+ STATUS deprecated
+ DESCRIPTION
+ "Arbitrary integer index to distinguish sensors associated with the same
+ chassis slot."
+ ::= { juniERXSysTempEntry 1 }
+
+juniERXSysTempDescr OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..63))
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "Textual description of this sensor."
+ ::= { juniERXSysTempEntry 2 }
+
+juniERXSysTempStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(0),
+ failed(1),
+ tooLow(2),
+ nominal(3),
+ tooHigh(4),
+ tooLowWarning(5),
+ tooHighWarning(6) }
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "The status of a temperature sensor:
+ unknown unknown
+ failed failed
+ tooLow below nominal range
+ nominal within nominal range
+ tooHigh above nominal range
+ tooLowWarning near lower limit
+ tooHighWarning near upper limit"
+ ::= { juniERXSysTempEntry 3 }
+
+juniERXSysTempValue OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "degrees Celsius"
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "The temperature measured by this sensor in degrees Celsius. This
+ measurement is valid only if the value of the corresponding
+ juniERXSysTempStatus is nominal."
+ ::= { juniERXSysTempEntry 4 }
+
+juniERXSysTempProtectionStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ monitoring(1),
+ inHoldOff(2),
+ activatedHoldOffExpired(3),
+ activatedTempTooHigh(4) }
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "Thermal protection status:
+ monitoring monitoring
+ inHoldOff hold off time has begun
+ activatedHoldOffExpired hold off time has expired, the system
+ is in thermal protection mode
+ activatedTempTooHigh temperature too high, the system is in
+ thermal protection mode "
+ ::= { juniERXSysTemperature 3 }
+
+juniERXSysTempProtectionHoldOffTime OBJECT-TYPE
+ SYNTAX Integer32 (0..1200)
+ UNITS "seconds"
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "The time, in seconds, before the system enters thermal protection mode
+ after a critical fan subsystem failure is detected."
+ DEFVAL { 150 }
+ ::= { juniERXSysTemperature 4 }
+
+juniERXSysTempProtectionHoldOffTimeRemaining OBJECT-TYPE
+ SYNTAX Integer32 (0..1200)
+ UNITS "seconds"
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "The time remaining, in seconds, before the system enters thermal
+ protection mode while the thermal protection status is set to inHoldOff.
+ The value decrements every second until it reaches zero, and the status
+ changes to activatedHoldOffExpired. When the thermal protection status
+ is not inHoldOff or activatedHoldOffExpired, the value is set to the
+ hold off time."
+ DEFVAL { 150 }
+ ::= { juniERXSysTemperature 5 }
+
+
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+--
+-- Subsystem objects
+--
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+juniERXSysSubsystemTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF JuniERXSysSubsystemEntry
+ MAX-ACCESS not-accessible
+ STATUS deprecated
+ DESCRIPTION
+ "Table of subsystems."
+ ::= { juniERXSysSubsystem 1 }
+
+juniERXSysSubsystemEntry OBJECT-TYPE
+ SYNTAX JuniERXSysSubsystemEntry
+ MAX-ACCESS not-accessible
+ STATUS deprecated
+ DESCRIPTION
+ "A table entry containing information pertaining to a subsystem."
+ INDEX { juniERXSysSubsystemIndex }
+ ::= { juniERXSysSubsystemTable 1 }
+
+JuniERXSysSubsystemEntry ::= SEQUENCE {
+ juniERXSysSubsystemIndex Integer32,
+ juniERXSysSubsystemName DisplayString,
+ juniERXSysSubsystemControl INTEGER,
+ juniERXSysSubsystemBootReleaseFile DisplayString,
+ juniERXSysSubsystemBootBackupReleaseFile DisplayString }
+
+juniERXSysSubsystemIndex OBJECT-TYPE
+ SYNTAX Integer32 (0..255)
+ MAX-ACCESS not-accessible
+ STATUS deprecated
+ DESCRIPTION
+ "Subsystem number."
+ ::= { juniERXSysSubsystemEntry 1 }
+
+juniERXSysSubsystemName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..128))
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "The name of the subsystem."
+ ::= { juniERXSysSubsystemEntry 2 }
+
+juniERXSysSubsystemControl OBJECT-TYPE
+ SYNTAX INTEGER {
+ noOperation(0),
+ noBoot(1),
+ noBootBackup(2) }
+ MAX-ACCESS read-write
+ STATUS deprecated
+ DESCRIPTION
+ "Administrative control of this subsystem:
+ noOperation Setting this value has no effect.
+ noBoot Deconfigure primary release file for the subsystem.
+ noBootBackup Deconfigure backup release file for the subsystem."
+ ::= { juniERXSysSubsystemEntry 3 }
+
+juniERXSysSubsystemBootReleaseFile OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..128))
+ MAX-ACCESS read-write
+ STATUS deprecated
+ DESCRIPTION
+ "The local boot release file name for this subsystem, with extension
+ .rel."
+ DEFVAL { "" }
+ ::= { juniERXSysSubsystemEntry 4 }
+
+juniERXSysSubsystemBootBackupReleaseFile OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..128))
+ MAX-ACCESS read-write
+ STATUS deprecated
+ DESCRIPTION
+ "The local backup boot release file name for this subsystem, with
+ extension .rel."
+ DEFVAL { "" }
+ ::= { juniERXSysSubsystemEntry 5 }
+
+
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+-- Traps & Trap Control
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+-- The juniERXSysTrap OBJECT IDENTIFIER is used to define SNMPv2
+-- Notifications that are easily translated into SNMPv1 Traps.
+
+juniERXSysSlotOperStatusChange NOTIFICATION-TYPE
+ OBJECTS {
+ juniERXSysSlotCurrentCardType,
+ juniERXSysSlotAdminStatus,
+ juniERXSysSlotOperStatus,
+ juniERXSysSlotDisableReason,
+ juniERXSysSlotSpareServer,
+ juniERXSysSlotAssociatedSlot,
+ juniERXSysSlotDescr }
+ STATUS deprecated
+ DESCRIPTION
+ "Reports a status change for a slot.
+
+ This trap is generated on a transition into a stable state (online or
+ disabled) or on a transition out of online."
+ ::= { juniERXSysTrap 1 }
+
+juniERXSysPowerStatusChange NOTIFICATION-TYPE
+ OBJECTS {
+ juniERXSysPowerStatus }
+ STATUS deprecated
+ DESCRIPTION
+ "Reports a change in the status of a power element."
+ ::= { juniERXSysTrap 2 }
+
+juniERXSysTempFanStatusChange NOTIFICATION-TYPE
+ OBJECTS {
+ juniERXSysTempFanStatus }
+ STATUS deprecated
+ DESCRIPTION
+ "Reports a transition between the three states of the fan subsystem.
+ When the fan subsystem transitions to the failed state the thermal
+ protection hold off time begins."
+ ::= { juniERXSysTrap 3 }
+
+juniERXSysTempStatusChange NOTIFICATION-TYPE
+ OBJECTS {
+ juniERXSysTempStatus }
+ STATUS deprecated
+ DESCRIPTION
+ "Reports a change in the temperature status. When the status
+ transitions to the tooHigh state the system enters thermal protection
+ mode."
+ ::= { juniERXSysTrap 4 }
+
+juniERXSysHighMemUtil NOTIFICATION-TYPE
+ OBJECTS {
+ juniERXSysMemCapacity,
+ juniERXSysMemUtilPct,
+ juniERXSysAbatedMemUtilThreshold,
+ juniERXSysHighMemUtilThreshold }
+ STATUS deprecated
+ DESCRIPTION
+ "Report system memory utilization has met the conditions of
+ juniERXSysHighMemUtilThreshold."
+ ::= { juniERXSysTrap 5 }
+
+juniERXSysAbatedMemUtil NOTIFICATION-TYPE
+ OBJECTS {
+ juniERXSysMemCapacity,
+ juniERXSysMemUtilPct,
+ juniERXSysAbatedMemUtilThreshold,
+ juniERXSysHighMemUtilThreshold }
+ STATUS deprecated
+ DESCRIPTION
+ "Reports system memory utilization has met the conditions of
+ juniERXSysAbatedMemUtilThreshold."
+ ::= { juniERXSysTrap 6 }
+
+juniERXSysTempProtectionStatusChange NOTIFICATION-TYPE
+ OBJECTS {
+ juniERXSysTempProtectionStatus,
+ juniERXSysTempProtectionHoldOffTimeRemaining }
+ STATUS deprecated
+ DESCRIPTION
+ "Notification about changes in the state of Thermal Protection. This
+ notification is sent when the tempProtectionStatus changes. It is also
+ sent when the holdOffTimeRemaining is 50% of the holdOffTime."
+ ::= { juniERXSysTrap 7 }
+
+
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+-- Conformance information
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+juniERXSysCompliances OBJECT IDENTIFIER ::= { juniERXSysConformance 1 }
+juniERXSysGroups OBJECT IDENTIFIER ::= { juniERXSysConformance 2 }
+
+--
+-- compliance statements
+--
+juniERXSysCompliance MODULE-COMPLIANCE
+ STATUS obsolete
+ DESCRIPTION
+ "Obsolete compliance statement for entities which implement the ERX
+ System MIB. This compliance statement became obsolete when new slot
+ information objects were added."
+ MODULE -- this module
+ MANDATORY-GROUPS {
+ juniERXSysGroup,
+ juniERXSysNotifyGroup }
+ ::= { juniERXSysCompliances 1 } -- JUNOSe 1.3
+
+juniERXSysCompliance1 MODULE-COMPLIANCE
+ STATUS obsolete
+ DESCRIPTION
+ "Obsolete compliance statement for entities which implement the ERX
+ System MIB. This compliance statement became obsolete when the timing
+ group was added."
+ MODULE -- this module
+ MANDATORY-GROUPS {
+ juniERXSysGeneralGroup,
+ juniERXSysFabricGroup,
+ juniERXSysNvsGroup,
+ juniERXSysSlotGroup,
+ juniERXSysPortGroup,
+ juniERXSysPowerGroup,
+ juniERXSysTemperatureGroup,
+ juniERXSysSubsystemGroup,
+ juniERXSysNotifyGroup }
+ ::= { juniERXSysCompliances 2 } -- JUNOSe 2.0
+
+juniERXSysCompliance2 MODULE-COMPLIANCE
+ STATUS obsolete
+ DESCRIPTION
+ "Obsolete compliance statement for entities which implement the ERX
+ System MIB. This compliance statement became obsolete when new memory
+ information objects and notifications were added."
+ MODULE -- this module
+ MANDATORY-GROUPS {
+ juniERXSysGeneralGroup,
+ juniERXSysTimingGroup,
+ juniERXSysFabricGroup,
+ juniERXSysNvsGroup,
+ juniERXSysSlotGroup,
+ juniERXSysPortGroup,
+ juniERXSysPowerGroup,
+ juniERXSysTemperatureGroup,
+ juniERXSysSubsystemGroup,
+ juniERXSysNotifyGroup }
+ ::= { juniERXSysCompliances 3 } -- JUNOSe 3.0
+
+juniERXSysCompliance3 MODULE-COMPLIANCE
+ STATUS obsolete
+ DESCRIPTION
+ "Obsolete compliance statement for entities which implement the ERX
+ System MIB. This compliance statement became obsolete when new system
+ temperature information objects and notifications were added."
+ MODULE -- this module
+ MANDATORY-GROUPS {
+ juniERXSysGeneralGroup2,
+ juniERXSysTimingGroup,
+ juniERXSysFabricGroup,
+ juniERXSysNvsGroup,
+ juniERXSysSlotGroup,
+ juniERXSysPortGroup,
+ juniERXSysPowerGroup,
+ juniERXSysTemperatureGroup,
+ juniERXSysSubsystemGroup,
+ juniERXSysNotifyGroup2 }
+ ::= { juniERXSysCompliances 4 } -- JUNOSe 3.2
+
+juniERXSysCompliance4 MODULE-COMPLIANCE
+ STATUS obsolete
+ DESCRIPTION
+ "Obsolete compliance statement for entities which implement the ERX
+ System MIB. This compliance statement became obsolete when the general
+ trap control object was added."
+ MODULE -- this module
+ MANDATORY-GROUPS {
+ juniERXSysGeneralGroup2,
+ juniERXSysTimingGroup,
+ juniERXSysFabricGroup,
+ juniERXSysNvsGroup,
+ juniERXSysSlotGroup,
+ juniERXSysPortGroup,
+ juniERXSysPowerGroup,
+ juniERXSysTemperatureGroup2,
+ juniERXSysSubsystemGroup,
+ juniERXSysNotifyGroup3 }
+ ::= { juniERXSysCompliances 5 } -- JUNOSe 3.3
+
+juniERXSysCompliance5 MODULE-COMPLIANCE
+ STATUS deprecated
+ DESCRIPTION
+ "The compliance statement for entities which implement the ERX System
+ MIB."
+ MODULE -- this module
+ MANDATORY-GROUPS {
+ juniERXSysGeneralGroup3,
+ juniERXSysTimingGroup,
+ juniERXSysFabricGroup,
+ juniERXSysNvsGroup,
+ juniERXSysSlotGroup,
+ juniERXSysPortGroup,
+ juniERXSysPowerGroup,
+ juniERXSysTemperatureGroup2,
+ juniERXSysSubsystemGroup,
+ juniERXSysNotifyGroup3 }
+ ::= { juniERXSysCompliances 6 } -- JUNOSe 4.1
+
+
+--
+-- units of conformance
+--
+juniERXSysGroup OBJECT-GROUP
+ OBJECTS {
+ -- General chassis objects
+ juniERXSysChassisRev,
+ juniERXSysSwVersion,
+ juniERXSysSwBuildDate,
+ juniERXSysRevertControl,
+ juniERXSysRevertTimeOfDay,
+ juniERXSysBootConfigControl,
+ juniERXSysBootBackupConfigControl,
+ juniERXSysBootForceBackupControl,
+ juniERXSysBootAutoRevertControl,
+ juniERXSysBootAutoRevertCountTolerance,
+ juniERXSysBootAutoRevertTimeTolerance,
+ juniERXSysBootReleaseFile,
+ juniERXSysBootConfigFile,
+ juniERXSysBootBackupReleaseFile,
+ juniERXSysBootBackupConfigFile,
+
+ -- Fabric objects
+ juniERXSysFabricSpeed,
+ juniERXSysFabricRev,
+
+ -- NVS objects
+ juniERXSysNvsStatus,
+ juniERXSysNvsCapacity,
+ juniERXSysNvsUtilPct,
+
+ -- Slot objects
+ juniERXSysSlotCount,
+ juniERXSysSlotDescr,
+ juniERXSysSlotCurrentCardType,
+ juniERXSysSlotRev,
+ juniERXSysSlotAdminStatus,
+ juniERXSysSlotOperStatus,
+ juniERXSysSlotDisableReason,
+ juniERXSysSlotExpectedCardType,
+ juniERXSysSlotControl,
+ juniERXSysSlotCpuUtilPct,
+ juniERXSysSlotMemUtilPct,
+ juniERXSysSlotIoaPresent,
+ juniERXSysSlotPortCount,
+ juniERXSysSlotLastChange,
+ juniERXSysSlotRedundancyLockout,
+ juniERXSysSlotRedundancyGroupId,
+ juniERXSysSlotSpareServer,
+ juniERXSysSlotAssociatedSlot,
+ juniERXSysSlotRevertControl,
+ juniERXSysSlotRedundancyRevertTime,
+ juniERXSysSlotBootReleaseFile,
+ juniERXSysSlotBootBackupReleaseFile,
+
+ -- Port objects
+ juniERXSysPortDescr,
+ juniERXSysPortType,
+ juniERXSysPortIfIndex,
+
+ -- Power objects
+ juniERXSysPowerDescr,
+ juniERXSysPowerStatus,
+
+ -- Temperature objects
+ juniERXSysTempFanStatus,
+ juniERXSysTempDescr,
+ juniERXSysTempStatus,
+ juniERXSysTempValue,
+
+ -- Subsystem objects
+ juniERXSysSubsystemName,
+ juniERXSysSubsystemControl,
+ juniERXSysSubsystemBootReleaseFile,
+ juniERXSysSubsystemBootBackupReleaseFile }
+ STATUS obsolete
+ DESCRIPTION
+ "Obsolete collection of management objects pertaining to system
+ capabilities in a Juniper product. This group became obsolete when new
+ slot information objects were added."
+ ::= { juniERXSysGroups 1 } -- JUNOSe 1.3
+
+juniERXSysNotifyGroup NOTIFICATION-GROUP
+ NOTIFICATIONS {
+ juniERXSysSlotOperStatusChange,
+ juniERXSysPowerStatusChange,
+ juniERXSysTempFanStatusChange,
+ juniERXSysTempStatusChange }
+ STATUS obsolete
+ DESCRIPTION
+ "Obsolete collection of management notifications pertaining to system
+ operations in a Juniper product. This group became obsolete when new
+ memory threshold notificaitons were added."
+ ::= { juniERXSysGroups 2 } -- JUNOSe 1.3
+
+juniERXSysGeneralGroup OBJECT-GROUP
+ OBJECTS {
+ juniERXSysChassisRev,
+ juniERXSysSwVersion,
+ juniERXSysSwBuildDate,
+ juniERXSysRevertControl,
+ juniERXSysRevertTimeOfDay,
+ juniERXSysBootConfigControl,
+ juniERXSysBootBackupConfigControl,
+ juniERXSysBootForceBackupControl,
+ juniERXSysBootAutoRevertControl,
+ juniERXSysBootAutoRevertCountTolerance,
+ juniERXSysBootAutoRevertTimeTolerance,
+ juniERXSysBootReleaseFile,
+ juniERXSysBootConfigFile,
+ juniERXSysBootBackupReleaseFile,
+ juniERXSysBootBackupConfigFile }
+ STATUS obsolete
+ DESCRIPTION
+ "Obsolete collection of management objects pertaining to general system
+ capabilities in a Juniper product. This group became obsolete when new
+ memory management objects were added."
+ ::= { juniERXSysGroups 3 } -- JUNOSe 2.0
+
+juniERXSysFabricGroup OBJECT-GROUP
+ OBJECTS {
+ juniERXSysFabricSpeed,
+ juniERXSysFabricRev }
+ STATUS deprecated
+ DESCRIPTION
+ "A collection of management objects pertaining to system fabric
+ capabilities in a Juniper product."
+ ::= { juniERXSysGroups 4 } -- JUNOSe 2.0
+
+juniERXSysNvsGroup OBJECT-GROUP
+ OBJECTS {
+ juniERXSysNvsStatus,
+ juniERXSysNvsCapacity,
+ juniERXSysNvsUtilPct }
+ STATUS deprecated
+ DESCRIPTION
+ "A collection of management objects pertaining to non-volitile storage
+ subsystem capabilities in a Juniper product."
+ ::= { juniERXSysGroups 5 } -- JUNOSe 2.0
+
+juniERXSysSlotGroup OBJECT-GROUP
+ OBJECTS {
+ juniERXSysSlotCount,
+ juniERXSysSlotDescr,
+ juniERXSysSlotCurrentCardType,
+ juniERXSysSlotRev,
+ juniERXSysSlotAdminStatus,
+ juniERXSysSlotOperStatus,
+ juniERXSysSlotDisableReason,
+ juniERXSysSlotExpectedCardType,
+ juniERXSysSlotControl,
+ juniERXSysSlotCpuUtilPct,
+ juniERXSysSlotMemUtilPct,
+ juniERXSysSlotIoaPresent,
+ juniERXSysSlotPortCount,
+ juniERXSysSlotLastChange,
+ juniERXSysSlotRedundancyLockout,
+ juniERXSysSlotRedundancyGroupId,
+ juniERXSysSlotSpareServer,
+ juniERXSysSlotAssociatedSlot,
+ juniERXSysSlotRevertControl,
+ juniERXSysSlotRedundancyRevertTime,
+ juniERXSysSlotBootReleaseFile,
+ juniERXSysSlotBootBackupReleaseFile,
+ juniERXSysSlotSerialNumber,
+ juniERXSysSlotAssemblyPartNumber,
+ juniERXSysSlotAssemblyRev,
+ juniERXSysSlotIoaSerialNumber,
+ juniERXSysSlotIoaAssemblyPartNumber,
+ juniERXSysSlotIoaAssemblyRev }
+ STATUS deprecated
+ DESCRIPTION
+ "A collection of management objects pertaining to slot-specific system
+ capabilities in a Juniper product."
+ ::= { juniERXSysGroups 6 } -- JUNOSe 2.0
+
+juniERXSysPortGroup OBJECT-GROUP
+ OBJECTS {
+ juniERXSysPortDescr,
+ juniERXSysPortType,
+ juniERXSysPortIfIndex }
+ STATUS deprecated
+ DESCRIPTION
+ "A collection of management objects pertaining to port-related system
+ capabilities in a Juniper product."
+ ::= { juniERXSysGroups 7 } -- JUNOSe 2.0
+
+juniERXSysPowerGroup OBJECT-GROUP
+ OBJECTS {
+ juniERXSysPowerDescr,
+ juniERXSysPowerStatus }
+ STATUS deprecated
+ DESCRIPTION
+ "A collection of management objects pertaining to the power subsystem
+ capabilities in a Juniper product."
+ ::= { juniERXSysGroups 8 } -- JUNOSe 2.0
+
+juniERXSysTemperatureGroup OBJECT-GROUP
+ OBJECTS {
+ juniERXSysTempFanStatus,
+ juniERXSysTempDescr,
+ juniERXSysTempStatus,
+ juniERXSysTempValue }
+ STATUS obsolete
+ DESCRIPTION
+ "Obsolete collection of management objects pertaining to system
+ temperature monitoring capabilities in a Juniper product. This group
+ became obsolete when temperature shutdown parameters were added."
+ ::= { juniERXSysGroups 9 } -- JUNOSe 2.0
+
+juniERXSysSubsystemGroup OBJECT-GROUP
+ OBJECTS {
+ juniERXSysSubsystemName,
+ juniERXSysSubsystemControl,
+ juniERXSysSubsystemBootReleaseFile,
+ juniERXSysSubsystemBootBackupReleaseFile }
+ STATUS deprecated
+ DESCRIPTION
+ "A collection of management objects pertaining to subsystem capabilities
+ in a Juniper product."
+ ::= { juniERXSysGroups 10 } -- JUNOSe 2.0
+
+juniERXSysTimingGroup OBJECT-GROUP
+ OBJECTS {
+ juniERXSysAdminTimingSource,
+ juniERXSysOperTimingSource,
+ juniERXSysTimingDisableAutoUpgrade,
+
+ juniERXSysTimingSourceType,
+ juniERXSysTimingSourceIfIndex,
+ juniERXSysTimingSourceLine,
+ juniERXSysTimingStatus }
+ STATUS deprecated
+ DESCRIPTION
+ "A collection of management objects pertaining to system timing
+ capabilities in a Juniper product."
+ ::= { juniERXSysGroups 11 } -- JUNOSe 3.0
+
+juniERXSysGeneralGroup2 OBJECT-GROUP
+ OBJECTS {
+ juniERXSysChassisRev,
+ juniERXSysSwVersion,
+ juniERXSysSwBuildDate,
+ juniERXSysRevertControl,
+ juniERXSysRevertTimeOfDay,
+ juniERXSysBootConfigControl,
+ juniERXSysBootBackupConfigControl,
+ juniERXSysBootForceBackupControl,
+ juniERXSysBootAutoRevertControl,
+ juniERXSysBootAutoRevertCountTolerance,
+ juniERXSysBootAutoRevertTimeTolerance,
+ juniERXSysBootReleaseFile,
+ juniERXSysBootConfigFile,
+ juniERXSysBootBackupReleaseFile,
+ juniERXSysBootBackupConfigFile,
+ juniERXSysMemUtilPct,
+ juniERXSysMemCapacity,
+ juniERXSysHighMemUtilThreshold,
+ juniERXSysAbatedMemUtilThreshold,
+ juniERXSysMemUtilTrapEnable }
+ STATUS obsolete
+ DESCRIPTION
+ "Obsolete collection of management objects pertaining to general system
+ capabilities in a Juniper product. This group became obsolete when the
+ general trap control object was added."
+ ::= { juniERXSysGroups 12 } -- JUNOSe 3.2
+
+juniERXSysNotifyGroup2 NOTIFICATION-GROUP
+ NOTIFICATIONS {
+ juniERXSysSlotOperStatusChange,
+ juniERXSysPowerStatusChange,
+ juniERXSysTempFanStatusChange,
+ juniERXSysTempStatusChange,
+ juniERXSysHighMemUtil,
+ juniERXSysAbatedMemUtil }
+ STATUS obsolete
+ DESCRIPTION
+ "Obsolete collection of management notifications pertaining to system
+ operations in a Juniper product. This group became obsolete when the
+ tempProtectionStatusChange notification was added."
+ ::= { juniERXSysGroups 13 } -- JUNOSe 3.2
+
+juniERXSysTemperatureGroup2 OBJECT-GROUP
+ OBJECTS {
+ juniERXSysTempFanStatus,
+ juniERXSysTempDescr,
+ juniERXSysTempStatus,
+ juniERXSysTempValue,
+ juniERXSysTempProtectionStatus,
+ juniERXSysTempProtectionHoldOffTime,
+ juniERXSysTempProtectionHoldOffTimeRemaining }
+ STATUS deprecated
+ DESCRIPTION
+ "A collection of management objects pertaining to system temperature
+ monitoring capabilities in a Juniper product."
+ ::= { juniERXSysGroups 14 } -- JUNOSe 3.3
+
+juniERXSysNotifyGroup3 NOTIFICATION-GROUP
+ NOTIFICATIONS {
+ juniERXSysSlotOperStatusChange,
+ juniERXSysPowerStatusChange,
+ juniERXSysTempFanStatusChange,
+ juniERXSysTempStatusChange,
+ juniERXSysHighMemUtil,
+ juniERXSysAbatedMemUtil,
+ juniERXSysTempProtectionStatusChange }
+ STATUS deprecated
+ DESCRIPTION
+ "A collection of management notifications pertaining to system
+ operations in a Juniper product."
+ ::= { juniERXSysGroups 15 } -- JUNOSe 3.3
+
+juniERXSysGeneralGroup3 OBJECT-GROUP
+ OBJECTS {
+ juniERXSysChassisRev,
+ juniERXSysSwVersion,
+ juniERXSysSwBuildDate,
+ juniERXSysRevertControl,
+ juniERXSysRevertTimeOfDay,
+ juniERXSysBootConfigControl,
+ juniERXSysBootBackupConfigControl,
+ juniERXSysBootForceBackupControl,
+ juniERXSysBootAutoRevertControl,
+ juniERXSysBootAutoRevertCountTolerance,
+ juniERXSysBootAutoRevertTimeTolerance,
+ juniERXSysBootReleaseFile,
+ juniERXSysBootConfigFile,
+ juniERXSysBootBackupReleaseFile,
+ juniERXSysBootBackupConfigFile,
+ juniERXSysMemUtilPct,
+ juniERXSysMemCapacity,
+ juniERXSysHighMemUtilThreshold,
+ juniERXSysAbatedMemUtilThreshold,
+ juniERXSysMemUtilTrapEnable,
+ juniERXSysGeneralTrapEnable }
+ STATUS deprecated
+ DESCRIPTION
+ "A collection of management objects pertaining to general system
+ capabilities in a Juniper product."
+ ::= { juniERXSysGroups 16 } -- JUNOSe 4.1
+
+END