diff --git a/MIBS/linksys/LINKSYS-rlInterfaces b/MIBS/linksys/LINKSYS-rlInterfaces new file mode 100644 index 0000000..2b4dd76 --- /dev/null +++ b/MIBS/linksys/LINKSYS-rlInterfaces @@ -0,0 +1,1309 @@ +LINKSYS-rlInterfaces DEFINITIONS ::= BEGIN
+
+-- Title: LINKSYS Switch Interfaces Private
+-- Version: 7.45
+-- Date: 07 May 2006
+-- 30-Nov-2004 Added type AutoNegCapabilitiesBits
+-- 30-Nov-2004 Added fields swIfAdminSpeedDuplexAutoNegotiationLocalCapabilities
+-- swIfOperSpeedDuplexAutoNegotiationLocalCapabilities
+-- swIfSpeedDuplexNegotiationRemoteCapabilities to swIfEntry
+-- 22-Nov-2005 Obsoleted field swIfPhysAddressType
+-- 22-Nov-2005 Added rlIfBaseMACAddressPerIfIndex
+-- 30-Oct-2005 Added swIfExtTable
+-- 30-Nov-2005 Added fields swIfAdminComboMode
+-- swIfOperComboMode swIfExtTable to swIfEntry
+-- 05-Dec-2005 Added rlFlowControlCascadeMode and rlFlowControlCascadeType
+-- 23-Feb-2005 Added rlFlowControlRxPerSystem
+-- 07-May-2006 Added rlCascadePortProtectionAction
+-- 04-Jun-2006 Added multiple-auth enum to swIfHostMode
+-- 11-Jun-2008 Added rlManagementIfIndex
+-- 06-Jun-2009 Added rlIfClearPortMacAddresses
+
+IMPORTS
+ rnd, rlIfInterfaces FROM LINKSYS-MIB
+ ifIndex, InterfaceIndex, InterfaceIndexOrZero FROM IF-MIB
+ PortList FROM Q-BRIDGE-MIB
+ Unsigned32, Integer32, Counter32,
+ MODULE-IDENTITY, OBJECT-TYPE FROM SNMPv2-SMI
+ RowStatus, TruthValue, TEXTUAL-CONVENTION,
+ DisplayString FROM SNMPv2-TC;
+
+
+swInterfaces MODULE-IDENTITY
+ LAST-UPDATED "201304010000Z" -- April 1, 2013
+ ORGANIZATION "Linksys LLC."
+ CONTACT-INFO
+ "www.linksys.com/business/support"
+ DESCRIPTION
+ "The MIB module describes the private MIB for Switch Interfaces supported
+ by Linksys MTS software and products."
+ REVISION "201304010000Z" -- April 1, 2013
+ DESCRIPTION
+ "Added MODULE-IDENTITY"
+ ::= { rnd 43 }
+
+
+-- These bits can be set in any combination (except unknown)
+-- for field swIfAdminSpeedDuplexAutoNegotiationLocalCapabilities
+-- and will take affect when field swIfSpeedDuplexAutoNegotiation
+-- will be set to enabled.
+-- In addition these fields can be read for operative values of
+-- auto negotiation capabilities
+AutoNegCapabilitiesBits ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "Auto negotiation capabilities bits."
+ SYNTAX BITS {
+ default(0),
+ unknown(1),
+ tenHalf(2),
+ tenFull(3),
+ fastHalf(4),
+ fastFull(5),
+ gigaHalf(6),
+ gigaFull(7),
+ tenGigaFull(8)
+ }
+
+--
+-- swTable
+--
+
+swIfTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SwIfEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Switch media specific information and configuration of the device
+ interfaces."
+ ::= { swInterfaces 1 }
+
+swIfEntry OBJECT-TYPE
+ SYNTAX SwIfEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Defines the contents of each line in the swIfTable table."
+ INDEX { swIfIndex }
+ ::= { swIfTable 1 }
+
+SwIfEntry ::= SEQUENCE {
+ swIfIndex INTEGER,
+ swIfPhysAddressType INTEGER,
+ swIfDuplexAdminMode INTEGER,
+ swIfDuplexOperMode INTEGER,
+ swIfBackPressureMode INTEGER,
+ swIfTaggedMode INTEGER,
+ swIfTransceiverType INTEGER,
+ swIfLockAdminStatus INTEGER,
+ swIfLockOperStatus INTEGER,
+ swIfType INTEGER,
+ swIfDefaultTag INTEGER,
+ swIfDefaultPriority INTEGER,
+ swIfStatus RowStatus,
+ swIfFlowControlMode INTEGER,
+ swIfSpeedAdminMode INTEGER,
+ swIfSpeedDuplexAutoNegotiation INTEGER,
+ swIfOperFlowControlMode INTEGER,
+ swIfOperSpeedDuplexAutoNegotiation INTEGER,
+ swIfOperBackPressureMode INTEGER,
+ swIfAdminLockAction INTEGER,
+ swIfOperLockAction INTEGER,
+ swIfAdminLockTrapEnable TruthValue,
+ swIfOperLockTrapEnable TruthValue,
+ swIfOperSuspendedStatus TruthValue,
+ swIfLockOperTrapCount INTEGER,
+ swIfLockAdminTrapFrequency INTEGER,
+ swIfReActivate TruthValue,
+ swIfAdminMdix INTEGER,
+ swIfOperMdix INTEGER,
+ swIfHostMode INTEGER,
+ swIfSingleHostViolationAdminAction INTEGER,
+ swIfSingleHostViolationOperAction INTEGER,
+ swIfSingleHostViolationAdminTrapEnable TruthValue,
+ swIfSingleHostViolationOperTrapEnable TruthValue,
+ swIfSingleHostViolationOperTrapCount INTEGER,
+ swIfSingleHostViolationAdminTrapFrequency INTEGER,
+ swIfLockLimitationMode INTEGER,
+ swIfLockMaxMacAddresses INTEGER,
+ swIfLockMacAddressesCount INTEGER,
+ swIfAdminSpeedDuplexAutoNegotiationLocalCapabilities AutoNegCapabilitiesBits,
+ swIfOperSpeedDuplexAutoNegotiationLocalCapabilities AutoNegCapabilitiesBits,
+ swIfSpeedDuplexNegotiationRemoteCapabilities AutoNegCapabilitiesBits,
+ swIfAdminComboMode INTEGER,
+ swIfOperComboMode INTEGER,
+ swIfAutoNegotiationMasterSlavePreference INTEGER
+ }
+
+
+swIfIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index to the swIfTable. The interface defined by a
+ particular value of this index is the same interface as
+ identified by the same value of ifIndex (MIB II)."
+ ::= { swIfEntry 1 }
+
+swIfPhysAddressType OBJECT-TYPE
+ SYNTAX INTEGER {
+ default(1),
+ reserve(2)
+ }
+ MAX-ACCESS read-write
+ STATUS obsolete
+ DESCRIPTION
+ " This variable indicates whether the physical address assigned to this
+ interface should be the default one or be chosen from the set of
+ reserved physical addresses of the device."
+ DEFVAL { default }
+ ::= { swIfEntry 2 }
+
+swIfDuplexAdminMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(1),
+ half(2),
+ full(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This variable specifies whether this interface should operate in
+ half duplex or full duplex mode. This specification will take effect
+ only if swIfSpeedDuplexAutoNegotiation is disabled.
+ A value of 'none' is returned if a value of the variable
+ hasn't been set."
+ DEFVAL { none }
+ ::= { swIfEntry 3 }
+
+swIfDuplexOperMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ half(1),
+ full(2),
+ hybrid(3),
+ unknown(4)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ " This variable indicates whether this interface operates in half
+ duplex or full duplex mode.
+ This variable can have the values hybrid or unknown
+ only for a trunk.
+ unknown - only if trunk operative status is not present."
+ ::= { swIfEntry 4 }
+
+swIfBackPressureMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ enable(1),
+ disable(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This variable indicates whether this interface activates back pressure
+ when congested."
+ ::= { swIfEntry 5 }
+
+swIfTaggedMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ enable(1),
+ disable(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "If enable, this interface operates in tagged mode, i.e all frames sent
+ out through this interface will have the 802.1Q header.
+ If disabled the frames will not be tagged."
+ DEFVAL { disable }
+ ::= { swIfEntry 6 }
+
+swIfTransceiverType OBJECT-TYPE
+ SYNTAX INTEGER {
+ regular(1),
+ fiberOptics(2),
+ comboRegular(3),
+ comboFiberOptics(4)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ " This variable indicates the transceiver type of this interface."
+ ::= { swIfEntry 7 }
+
+swIfLockAdminStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ locked(1),
+ unlocked(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This variable indicates whether this interface should operate in locked
+ or unlocked mode.
+ In unlocked mode the device learns all MAC addresses from this port and
+ forwards all frames arrived at this port. In locked mode no new MAC
+ addresses are learned and only frames with known source MAC
+ addresses are forwarded."
+ DEFVAL { unlocked }
+ ::= { swIfEntry 8 }
+
+swIfLockOperStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ locked(1),
+ unlocked(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This variable defines whether this interface operates in locked
+ or unlocked mode. It is locked in each of the following two cases:
+ 1) if swLockAdminStatus is set to locked
+ 2) no IP/IPX interface is defined over this interface and no
+ VLAN contains this interface.
+ In unlocked mode the device learns all MAC addresses from this port and
+ forwards all frames arrived at this port. In locked mode no new MAC
+ addresses are learned and only frames with known source MAC
+ addresses are forwarded."
+ ::= { swIfEntry 9 }
+
+swIfType OBJECT-TYPE
+ SYNTAX INTEGER {
+ eth10M(1),
+ eth100M(2),
+ eth1000M(3),
+ eth10G(4),
+ unknown(5)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ " This variable specifies the type of interface."
+ ::= { swIfEntry 10 }
+
+swIfDefaultTag OBJECT-TYPE
+ SYNTAX INTEGER (0..4095)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This variable specifies the default VLAN tag which will be attached
+ to outgoing frames if swIfTaggedMode for this interface is enabled."
+ DEFVAL { 0 }
+ ::= { swIfEntry 11 }
+
+swIfDefaultPriority OBJECT-TYPE
+ SYNTAX INTEGER (0..7)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ " This variable specifies the default port priority."
+ DEFVAL { 0 }
+ ::= { swIfEntry 12 }
+
+swIfStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The status of a table entry.
+ It is used to delete an entry from this table."
+ ::= { swIfEntry 13 }
+
+swIfFlowControlMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ on(1),
+ off(2),
+ autoNegotiation(3),
+ enabledRx(4),
+ enabledTx(5)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "on - Flow control will be enabled on this interface according to the
+ IEEE 802.3x standard.
+ off - Flow control is disabled.
+ autoNegotiation - Flow control will be enabled or disabled on this
+ interface. If enabled, it will operate as specified
+ by the IEEE 802.3x standard.
+ enabledRx - Flow control will be enabled on this interface for
+ recieved frames.
+ enabledTx - Flow control will be enabled on this interface for
+ transmitted frames.
+ An attempt to set this object to 'enabledRx(4)' or 'enabledTx(5)'
+ will fail on interfaces that do not support operation
+ at greater than 100 Mb/s.
+ In any case, flow control can work only if swIfDuplexOperMode is
+ full."
+ ::= { swIfEntry 14}
+
+swIfSpeedAdminMode OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This variable specifies the required speed of this interface in bits
+ per second. This specification will take effect only if
+ swIfSpeedDuplexAutoNegotiation is disabled.
+ A value of 10 is returned for 10G.
+ A value of 0 is returned if the value of the variable
+ hasn't been set."
+ DEFVAL { 0 }
+ ::= { swIfEntry 15 }
+
+swIfSpeedDuplexAutoNegotiation OBJECT-TYPE
+ SYNTAX INTEGER {
+ enabled(1),
+ disabled(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "If enabled the speed and duplex mode will be set by the device through
+ the autonegotiation process. Otherwise these characteristics will be
+ set according to the values of swIfSpeedAdminMode and
+ swIfSpeedDuplexAutoNegotiation."
+ ::= { swIfEntry 16 }
+
+swIfOperFlowControlMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ on(1),
+ off(2),
+ enabledRx(3),
+ enabledTx(4)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "on - Flow control is enabled on this interface according to the
+ IEEE 802.3x standard.
+ off - Flow control is disabled.
+ enabledRx - Flow control is enabled on this interface for
+ recieved frames.
+ enabledTx - Flow control is enabled on this interface for
+ transmitted frames."
+ ::= { swIfEntry 17}
+
+swIfOperSpeedDuplexAutoNegotiation OBJECT-TYPE
+ SYNTAX INTEGER {
+ enabled(1),
+ disabled(2),
+ hybrid(3),
+ unknown(4)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "If enabled the speed and duplex are determined by the device through
+ the autonegotiation process.
+ If disabled these characteristics are determined according to the values
+ of swIfSpeedAdminMode and swIfDuplexAdminMode.
+ hybrid - only for a trunk.
+ unknown - only for ports that there operative status is not present."
+ ::= { swIfEntry 18 }
+
+swIfOperBackPressureMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ enable(1),
+ disable(2),
+ hybrid(3),
+ unknown(4)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This variable indicates the operative back pressure mode of
+ this interface."
+ ::= { swIfEntry 19 }
+
+swIfAdminLockAction OBJECT-TYPE
+ SYNTAX INTEGER {
+ discard(1),
+ forwardNormal(2),
+ discardDisable(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This variable indicates which action this interface should be taken
+ in locked mode and therefore relevant only in locked mode.
+ Possible actions:
+ discard(1) - every packet is dropped.
+ forwardNormal(2) - every packet is forwarded according to the DST address.
+ discardDisable(3) - drops the first packet and suspends the port."
+ --DEFVAL { discard } changed to product specific
+ ::= { swIfEntry 20 }
+
+
+swIfOperLockAction OBJECT-TYPE
+ SYNTAX INTEGER {
+ discard(1),
+ forwardNormal (2),
+ discardDisable(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This variable indicates which action this interface actually takes in
+ locked mode and therefore relevant only in locked mode.
+ Possible actions:
+ discard(1) - every packet is dropped.
+ forwardNormal(2) - every packet is forwarded according to the DST address.
+ discardDisable(3) - drops the first packet and suspends the port."
+ ::= { swIfEntry 21 }
+
+
+swIfAdminLockTrapEnable OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This variable indicates whether to create a SNMP trap in the locked mode."
+ --DEFVAL { false } changed to product specific
+ ::= { swIfEntry 22 }
+
+swIfOperLockTrapEnable OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This variable indicates whether a SNMP trap can be created in the
+ locked mode."
+ ::= { swIfEntry 23 }
+
+swIfOperSuspendedStatus OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This variable indicates whether the port is suspended or not due to some
+ feature. After reboot this value is false"
+ ::= { swIfEntry 24 }
+
+swIfLockOperTrapCount OBJECT-TYPE
+ SYNTAX INTEGER (0 .. 2147483647 )
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This variable indicates the trap counter status per ifIndex
+ (i.e. number of received packets since the last trap sent due to a
+ packet which was received on this ifIndex). It's relevant only in locked
+ mode while trap is enabled."
+ ::= { swIfEntry 25 }
+
+swIfLockAdminTrapFrequency OBJECT-TYPE
+ SYNTAX INTEGER (1 .. 1000000)
+-- UNITS "seconds"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This variable indicates the minimal frequency (in seconds) of sending
+ a trap per ifIndex. It's relevant only in locked mode and in trap
+ enabled."
+ --DEFVAL { 10 } changed to product specific
+ ::= { swIfEntry 26 }
+
+swIfReActivate OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This variable reactivates (enables) an ifIndex (which was suspended)"
+ DEFVAL { false }
+ ::= { swIfEntry 27 }
+
+swIfAdminMdix OBJECT-TYPE
+ SYNTAX INTEGER {
+ cross(1),
+ normal(2),
+ auto(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The configuration is on a physical port, not include trunks.
+ cross - The interface should force crossover.
+ normal - The interface should not force crossover.
+ auto - Auto mdix is enabled on the interface."
+ ::= { swIfEntry 28 }
+
+swIfOperMdix OBJECT-TYPE
+ SYNTAX INTEGER {
+ cross(1),
+ normal(2),
+ unknown(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "cross - The interface is in crossover mode.
+ normal - The interface is not in crossover mode.
+ unknown - Only for port that its operative status is not present
+ or down."
+ ::= { swIfEntry 29 }
+
+swIfHostMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ single(1),
+ multiple(2),
+ multiple-auth(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This variable indicates the 802.1X host mode of a port. Relevant when the port's 802.1X control is auto.
+ In addtion multiple-auth was added."
+ DEFVAL { single }
+ ::= { swIfEntry 30 }
+
+swIfSingleHostViolationAdminAction OBJECT-TYPE
+ SYNTAX INTEGER {
+ discard(1),
+ forwardNormal (2),
+ discardDisable(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This variable indicates which action this interface should take in single authorized.
+ Possible actions:
+ discard - every packet is dropped.
+ forwardNormal - every packet is forwarded according to the DST address.
+ discardDisable - drops the first packet and suspends the port."
+ DEFVAL { discard }
+ ::= { swIfEntry 31 }
+
+swIfSingleHostViolationOperAction OBJECT-TYPE
+ SYNTAX INTEGER {
+ discard(1),
+ forwardNormal (2),
+ discardDisable(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This variable indicates which action this interface actually takes in single authorized.
+ Possible actions:
+ discard(1) - every packet is dropped.
+ forwardNormal(2) - every packet is forwarded according to the DST address.
+ discardDisable(3) - drops the first packet and suspends the port."
+ DEFVAL { discard }
+ ::= { swIfEntry 32 }
+
+swIfSingleHostViolationAdminTrapEnable OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This variable indicates whether to create a SNMP trap in single authorized."
+ DEFVAL { false }
+ ::= { swIfEntry 33 }
+
+swIfSingleHostViolationOperTrapEnable OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This variable indicates whether a SNMP trap can be created in the single authorized."
+ ::= { swIfEntry 34 }
+
+swIfSingleHostViolationOperTrapCount OBJECT-TYPE
+ SYNTAX INTEGER (0 .. 2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This variable indicates the trap counter status per ifIndex
+ (i.e. number of received packets since the last trap sent due to a packet
+ which was received on this ifIndex). It's relevant only in single authorized
+ while trap is enabled."
+ ::= { swIfEntry 35 }
+
+swIfSingleHostViolationAdminTrapFrequency OBJECT-TYPE
+ SYNTAX INTEGER (0 .. 1000000)
+ -- UNITS "seconds"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This variable indicates the minimal frequency (in seconds) of sending a
+ trap per ifIndex. It's relevant only in single authorized and in trap enabled.
+ A value of 0 means that trap is disabled."
+ DEFVAL { 0 }
+ ::= { swIfEntry 36 }
+
+swIfLockLimitationMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(1),
+ dynamic(2),
+ secure-permanent(3),
+ secure-delete-on-reset(4)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This variable indicates what is the learning limitation on the locked interface.
+ Possible values:
+ disabled - learning is stopped. The dynamic addresses associated with the
+ port are not aged out or relearned on other port as long as the port is
+ locked.
+ dynamic - dynamic addresses can be learned up to the maximum dynamic addresses
+ allowed on the port. Relearning and aging of the dynamic addresses are
+ enabled. The learned addresses aren't kept after reset.
+ secure-permanent - secure addresses can be learned up to the maximum addresses
+ allowed on the port. Relearning and aging of addresses are disabled.
+ The learned addresses are kept after reset.
+ secure-delete-on-reset - secure addresses can be learned up to the maximum addresses
+ allowed on the port. Relearning and aging of addresses are disabled.
+ The learned addresses are not kept after reset."
+ --DEFVAL { disabled } changed to product specific
+ ::= { swIfEntry 37 }
+
+swIfLockMaxMacAddresses OBJECT-TYPE
+ SYNTAX INTEGER (0 .. 2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This variable defines the maximum number of dynamic addresses that
+ can be asscoiated with the locked interface. It isn't relevant in
+ disabled limitation mode."
+ DEFVAL { 1 }
+ ::= { swIfEntry 38 }
+
+swIfLockMacAddressesCount OBJECT-TYPE
+ SYNTAX INTEGER (0 .. 2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This variable indicates the actual number of dynamic addresses that can
+ be asscoiated with the locked interface. It isn't relevant in disabled
+ limitation mode."
+ ::= { swIfEntry 39 }
+
+swIfAdminSpeedDuplexAutoNegotiationLocalCapabilities OBJECT-TYPE
+ SYNTAX AutoNegCapabilitiesBits
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Administrative auto negotiation capabilities of the interface that can be advertised when
+ swIfSpeedDuplexAutoNegotiation is enabled.
+ default bit means advertise all the port's capabilities
+ according to its type."
+ DEFVAL { {default} }
+ ::= { swIfEntry 40 }
+
+swIfOperSpeedDuplexAutoNegotiationLocalCapabilities OBJECT-TYPE
+ SYNTAX AutoNegCapabilitiesBits
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Operative auto negotiation capabilities of the remote link.
+ unknown bit means that port operative status is not up."
+ ::= { swIfEntry 41 }
+
+swIfSpeedDuplexNegotiationRemoteCapabilities OBJECT-TYPE
+ SYNTAX AutoNegCapabilitiesBits
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Operative auto negotiation capabilities of the remote link.
+ unknown bit means that port operative status is not up,
+ or auto negotiation process not complete,
+ or remote link is not auto negotiation able."
+ ::= { swIfEntry 42 }
+
+swIfAdminComboMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ force-fiber(1),
+ force-copper(2),
+ prefer-fiber(3),
+ prefer-copper(4)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This variable specifies the administrative mode of a combo Ethernet interface."
+ DEFVAL { prefer-fiber }
+ ::= { swIfEntry 43 }
+
+swIfOperComboMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ fiber(1),
+ copper(2),
+ unknown(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This variable specifies the operative mode of a combo Ethernet interface."
+ ::= { swIfEntry 44 }
+
+swIfAutoNegotiationMasterSlavePreference OBJECT-TYPE
+ SYNTAX INTEGER {
+ preferMaster(1),
+ preferSlave(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This variable specifies the administrative mode of the Maste-Slave preference in auto negotiation."
+-- DEFVAL - according to MTSC parameter
+ ::= { swIfEntry 45 }
+
+
+
+--
+-- swIfMibVersion
+--
+swIfMibVersion OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The swIfTable Mib's version, the current version is 3."
+ ::= { swInterfaces 2 }
+
+
+--
+-- swIfPortLockSupport
+--
+swIfPortLockSupport OBJECT-TYPE
+ SYNTAX INTEGER {
+ supported (1),
+ notSupported (2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "indicates if the locked port package is supported."
+ ::= { swInterfaces 3 }
+
+
+--
+-- swIfPortLockActionSupport
+--
+swIfPortLockActionSupport OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(1))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "indicates which port lock actions are supported:
+ (bit 0 is the most significant bit)
+ bit 0 - discard
+ bit 1 - forwardNormal
+ bit 2 - discardDisable"
+ ::= { swInterfaces 4 }
+
+
+--
+-- swIfPortLockTrapSupport
+--
+swIfPortLockTrapSupport OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(1))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "indicates with which port lock actions the trap option is supported
+ (e.g. discard indicates that trap is supported only when the portlock
+ action is discard):
+ (bit 0 is the most significant bit)
+ bit 0 - discard
+ bit 1 - forwardNormal
+ bit 2 - discardDisable"
+ ::= { swInterfaces 5 }
+
+
+
+--
+-- swIfPortLockIfRangeTable
+--
+swIfPortLockIfRangeTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SwIfPortLockIfRangeEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Port lock interfaces range configuration"
+ ::= { swInterfaces 6 }
+
+swIfPortLockIfRangeEntry OBJECT-TYPE
+ SYNTAX SwIfPortLockIfRangeEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Defines the contents of each line in the swIfPortLockIfRangeTable table."
+ INDEX { swIfPortLockIfRangeIndex }
+ ::= { swIfPortLockIfRangeTable 1 }
+
+SwIfPortLockIfRangeEntry ::= SEQUENCE {
+ swIfPortLockIfRangeIndex INTEGER,
+ swIfPortLockIfRange PortList,
+ swIfPortLockIfRangeLockStatus INTEGER,
+ swIfPortLockIfRangeAction INTEGER,
+ swIfPortLockIfRangeTrapEn TruthValue,
+ swIfPortLockIfRangeTrapFreq INTEGER
+ }
+
+swIfPortLockIfRangeIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index to the swIfPortLockIfRangeTable."
+ ::= { swIfPortLockIfRangeEntry 1 }
+
+swIfPortLockIfRange OBJECT-TYPE
+ SYNTAX PortList
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The set of interfaces to which the port lock parameters should be configured"
+ ::= { swIfPortLockIfRangeEntry 2 }
+
+swIfPortLockIfRangeLockStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ locked(1),
+ unlocked(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This variable indicates whether the interfaces range should operate in locked
+ or unlocked mode.
+ In unlocked mode the device learns all MAC addresses from these interfaces and
+ forwards all frames arrived at these interfaces. In locked mode no new MAC
+ addresses are learned and only frames with known source MAC
+ addresses are forwarded."
+ DEFVAL { unlocked }
+ ::= { swIfPortLockIfRangeEntry 3 }
+
+swIfPortLockIfRangeAction OBJECT-TYPE
+ SYNTAX INTEGER {
+ discard(1),
+ forwardNormal(2),
+ discardDisable(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This variable indicates which action for these interfaces should be take
+ in locked mode and therefore relevant only in locked mode.
+ Possible actions:
+ discard(1) - every packet is dropped.
+ forwardNormal(2) - every packet is forwarded according to the DST address.
+ discardDisable(3) - drops the first packet and suspends the port."
+ --DEFVAL { discard } changed to product specific
+ ::= { swIfPortLockIfRangeEntry 4 }
+
+swIfPortLockIfRangeTrapEn OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This variable indicates whether to create a SNMP trap in the locked mode."
+ --DEFVAL { false } changed to product specific
+ ::= { swIfPortLockIfRangeEntry 5 }
+
+swIfPortLockIfRangeTrapFreq OBJECT-TYPE
+ SYNTAX INTEGER (1 .. 1000000)
+-- UNITS "seconds"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This variable indicates the minimal frequency (in seconds) of sending
+ a trap for these interfaces. It's relevant only in locked mode and in trap
+ enabled."
+ --DEFVAL { 10 } changed to product specific
+ ::= { swIfPortLockIfRangeEntry 6 }
+
+--
+-- swIfExtTable
+--
+
+swIfExtTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SwIfExtEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Display information and configuration of the device interfaces."
+ ::= { swInterfaces 7 }
+
+swIfExtEntry OBJECT-TYPE
+ SYNTAX SwIfExtEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Defines the contents of each row in the swIfExtTable."
+ INDEX { ifIndex }
+ ::= { swIfExtTable 1 }
+
+SwIfExtEntry ::= SEQUENCE {
+ swIfExtSFPSpeed INTEGER
+ }
+
+swIfExtSFPSpeed OBJECT-TYPE
+ SYNTAX INTEGER {
+ default(1),
+ eth100M(2),
+ eth1G(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Configure speed of an SFP Ethernet interface."
+ DEFVAL { default }
+ ::= { swIfExtEntry 1 }
+
+--
+-- rlIfInterfaces
+--
+
+rlIfMibVersion OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "MIB's version, the current version is 1."
+ ::= { rlIfInterfaces 1 }
+
+rlIfNumOfPhPorts OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of physical ports on this device
+ (including all stack units)"
+ ::= { rlIfInterfaces 2 }
+
+rlIfMapOfOnPhPorts OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Each bit in this octet string indicates that the correspondig port's
+ ifOperStatus is ON if set.
+ The mapping of port number to bits in this octet string is as follows:
+ The port with the L2 interface number 1 is mapped to the least
+ significant bit of the 1st octet, the port with L2 ifNumber 2 to the
+ next significant bit in the 1st octet, port 8 to the most-significant
+ bit of the in the 1st octet, port 9 to the least
+ significant bit of the 2nd octet, etc. and in general,
+ port n to bit corresponding to 2**((n mod 8) -1) in byte n/8 + 1"
+ ::= { rlIfInterfaces 3 }
+
+rlIfClearPortMibCounters OBJECT-TYPE
+ SYNTAX PortList
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Each bit that is set in this portList represent a port that
+ its mib counters should be reset."
+ ::= { rlIfInterfaces 4 }
+
+rlIfNumOfUserDefinedPorts OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of user defined ports on this device."
+ ::= { rlIfInterfaces 5 }
+
+rlIfFirstOutOfBandIfIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "First ifIndex of out-of-band port.
+ This scalar exists only the device has out of band ports."
+ ::= { rlIfInterfaces 6 }
+
+rlIfNumOfLoopbackPorts OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of loopback ports on this device."
+ ::= { rlIfInterfaces 7 }
+
+rlIfFirstLoopbackIfIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "First ifIndex of loopback port.
+ This scalar will exists only if rlIfNumOfLoopbackPorts
+ is different from 0."
+ ::= { rlIfInterfaces 8 }
+
+rlIfExistingPortList OBJECT-TYPE
+ SYNTAX PortList
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates which ports/trunks exist in the system.
+ It doesn't indicate which are present."
+ ::= { rlIfInterfaces 9 }
+
+rlIfBaseMACAddressPerIfIndex OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Indicates if the system will assign a unique MAC per Ethernet port or not."
+ ::= { rlIfInterfaces 10 }
+
+rlFlowControlCascadeMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ enabled(1),
+ disabled(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "enable disable flow control on cascade ports"
+ ::= { rlIfInterfaces 11 }
+
+rlFlowControlCascadeType OBJECT-TYPE
+ SYNTAX INTEGER {
+ internalonly(1),
+ internalexternal(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "define which type of ports will be affected by flow control on cascade ports"
+ ::= { rlIfInterfaces 12 }
+
+rlFlowControlRxPerSystem OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "define if flow control RX is supported per system."
+ ::= { rlIfInterfaces 13 }
+
+rlCascadePortProtectionAction OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "As a result of this set all of the local cascade ports
+ will stop being consider unstable and will be force up."
+ ::= { rlIfInterfaces 14 }
+
+rlManagementIfIndex OBJECT-TYPE
+ SYNTAX InterfaceIndex
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Specify L2 bound management interface index in a single IP address system
+ when configurable management interface is supported."
+ ::= { rlIfInterfaces 15 }
+
+rlIfClearStackPortsCounters OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "As a result of this set all counters of
+ all external cascade ports will be cleared."
+ ::= { rlIfInterfaces 16 }
+
+rlIfClearPortMacAddresses OBJECT-TYPE
+ SYNTAX InterfaceIndexOrZero
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "if port is non secure, its all dynamic MAC addresses are cleared.
+ if port is secure, its all secure MAC addresses which have learned or configured are cleared."
+ ::= { rlIfInterfaces 17 }
+
+rlIfCutThroughPacketLength OBJECT-TYPE
+ SYNTAX INTEGER (257 .. 16383)
+ MAX-ACCESS read-write
+-- Obsolete
+ STATUS current
+ DESCRIPTION
+ "The default packet length that is assigned to a packet in the
+ Cut-Through mode."
+ DEFVAL { 1522 }
+ ::= { rlIfInterfaces 18 }
+
+rlIfCutPriorityZero OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable or disable cut-Through for priority 0."
+ DEFVAL { false }
+ ::= { rlIfInterfaces 19 }
+
+rlIfCutPriorityOne OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable or disable cut-Through for priority 1."
+ DEFVAL { false }
+ ::= { rlIfInterfaces 20 }
+
+rlIfCutPriorityTwo OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable or disable cut-Through for priority 2."
+ DEFVAL { false }
+ ::= { rlIfInterfaces 21 }
+
+rlIfCutPriorityThree OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable or disable cut-Through for priority 3."
+ DEFVAL { false }
+ ::= { rlIfInterfaces 22 }
+
+rlIfCutPriorityFour OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable or disable cut-Through for priority 4."
+ DEFVAL { false }
+ ::= { rlIfInterfaces 23 }
+
+rlIfCutPriorityFive OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable or disable cut-Through for priority 5."
+ DEFVAL { false }
+ ::= { rlIfInterfaces 24 }
+
+rlIfCutPrioritySix OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable or disable cut-Through for priority 6."
+ DEFVAL { false }
+ ::= { rlIfInterfaces 25 }
+
+rlIfCutPrioritySeven OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable or disable cut-Through for priority 7."
+ DEFVAL { false }
+ ::= { rlIfInterfaces 26 }
+
+rlIfCutThroughTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF RlIfCutThroughEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Information and configuration of cut-through feature."
+ ::= { rlIfInterfaces 27 }
+
+rlIfCutThroughEntry OBJECT-TYPE
+ SYNTAX RlIfCutThroughEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Defines the contents of each line in the swIfTable table."
+ INDEX { swIfIndex }
+ ::= { rlIfCutThroughTable 1 }
+
+RlIfCutThroughEntry ::= SEQUENCE {
+ rlIfCutThroughPriorityEnable TruthValue,
+ rlIfCutThroughUntaggedEnable TruthValue,
+ rlIfCutThroughOperMode TruthValue
+ }
+
+rlIfCutThroughPriorityEnable OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable or disable cut-through for a priority for an interface."
+ DEFVAL { false }
+ ::= { rlIfCutThroughEntry 1 }
+
+rlIfCutThroughUntaggedEnable OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable or disable cut-through for untagged packets for an interface."
+ DEFVAL { false }
+ ::= { rlIfCutThroughEntry 2 }
+
+rlIfCutThroughOperMode OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Operational mode of spesific cut-through interface."
+ ::= { rlIfCutThroughEntry 3 }
+
+rlCutThroughPacketLength OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The default packet length that is assigned to a packet in the
+ Cut-Through mode."
+ ::= { rlIfInterfaces 28 }
+
+rlCutThroughPacketLengthAfterReset OBJECT-TYPE
+ SYNTAX INTEGER (257 .. 16383)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The default packet length that is assigned to a packet in the
+ Cut-Through mode after reset."
+ DEFVAL { 1522 }
+ ::= { rlIfInterfaces 29 }
+
+rlCutThroughEnable OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cut-Through global enable mode."
+ ::= { rlIfInterfaces 30 }
+
+rlCutThroughEnableAfterReset OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Cut-Through global enable mode after reset."
+ DEFVAL { false }
+ ::= { rlIfInterfaces 31 }
+
+rlFlowControlMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ send-receive(1),
+ receive-only(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Define which mode will be enabled on flow control enabled ports.
+ The interfaces with enabled flow control will receive pause frames, but will not send flow control pause
+ frames
+ Send-receive: The interfaces with enabled flow control will receive and send pause frames.
+ Receive-only: The interfaces with enabled flow control will receive pause frames, but will not send flow
+ control pause frames."
+
+ ::= { rlIfInterfaces 32 }
+
+
+