summaryrefslogtreecommitdiff
path: root/MIBS/opengear/OGTRAP-MIB
diff options
context:
space:
mode:
authorDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
committerDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
commit98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch)
tree9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/opengear/OGTRAP-MIB
downloadmibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.tar.gz
mibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.zip
Initial commitHEADmain
Diffstat (limited to 'MIBS/opengear/OGTRAP-MIB')
-rw-r--r--MIBS/opengear/OGTRAP-MIB401
1 files changed, 401 insertions, 0 deletions
diff --git a/MIBS/opengear/OGTRAP-MIB b/MIBS/opengear/OGTRAP-MIB
new file mode 100644
index 0000000..ff926ae
--- /dev/null
+++ b/MIBS/opengear/OGTRAP-MIB
@@ -0,0 +1,401 @@
+OGTRAP-MIB DEFINITIONS ::= BEGIN
+
+ IMPORTS
+ OBJECT-TYPE
+ FROM RFC-1212
+ TRAP-TYPE
+ FROM RFC-1215
+ enterprises FROM
+ RFC1155-SMI;
+
+ opengear OBJECT IDENTIFIER ::= { enterprises 25049 }
+
+ ogLegacyMgmt OBJECT IDENTIFIER ::= { opengear 2 }
+
+ ogConnectMib OBJECT IDENTIFIER ::= { ogLegacyMgmt 10 }
+ ogSignalMib OBJECT IDENTIFIER ::= { ogLegacyMgmt 11 }
+ ogPatternMib OBJECT IDENTIFIER ::= { ogLegacyMgmt 12 }
+ ogSensorMib OBJECT IDENTIFIER ::= { ogLegacyMgmt 13 }
+ ogHostMib OBJECT IDENTIFIER ::= { ogLegacyMgmt 14 }
+ ogFailoverMib OBJECT IDENTIFIER ::= { ogLegacyMgmt 15 }
+ ogNetUpsMib OBJECT IDENTIFIER ::= { ogLegacyMgmt 16 }
+ ogDataMib OBJECT IDENTIFIER ::= { ogLegacyMgmt 17 }
+
+ -- Serial port connection traps.
+ ogConnectMibObjects OBJECT IDENTIFIER ::= { ogConnectMib 10 }
+ ogconnEvent OBJECT IDENTIFIER ::= { ogConnectMibObjects 1 }
+ ogconnEventTable OBJECT IDENTIFIER ::= { ogconnEvent 1 }
+ ogconnEventEntry OBJECT IDENTIFIER ::= { ogconnEventTable 1 }
+
+ ogconnEventUsername OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The user pertaining to the connection event"
+ ::= { ogconnEventEntry 10 }
+
+ ogconnEventType OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The type of connection event"
+ ::= { ogconnEventEntry 11 }
+
+ ogconnEventPortNumber OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Serial port number on which this connection applies"
+ ::= { ogconnEventEntry 12 }
+
+ ogconnEventPortLabel OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The label for the serial port where the connection
+ occurred."
+ ::= { ogconnEventEntry 13 }
+
+ ogconnEventOccurred TRAP-TYPE
+ ENTERPRISE opengear
+ VARIABLES {
+ ogconnEventUsername,
+ ogconnEventType,
+ ogconnEventPortNumber,
+ ogconnEventPortLabel
+ }
+ DESCRIPTION
+ "The alert sent when a user connection event occurs."
+ ::= 1001
+
+ -- Serial port signal trap
+ ogSignalMibObjects OBJECT IDENTIFIER ::= { ogSignalMib 10 }
+ ogsgnlEvent OBJECT IDENTIFIER ::= { ogSignalMibObjects 1 }
+ ogsgnlEventTable OBJECT IDENTIFIER ::= { ogsgnlEvent 1 }
+ ogsgnlEventEntry OBJECT IDENTIFIER ::= { ogsgnlEventTable 1 }
+
+ ogsgnlEventType OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The particular signal which changed"
+ ::= { ogsgnlEventEntry 10 }
+
+ ogsgnlEventState OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The current signal state"
+ ::= { ogsgnlEventEntry 11 }
+
+ ogsgnlEventPortNumber OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Serial port number on which this signal applies"
+ ::= { ogsgnlEventEntry 12 }
+
+ ogsgnlEventPortLabel OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The label for the serial port where the signal applies."
+ ::= { ogsgnlEventEntry 13 }
+
+ ogsgnlEventOccurred TRAP-TYPE
+ ENTERPRISE opengear
+ VARIABLES {
+ ogsgnlEventType,
+ ogsgnlEventState,
+ ogsgnlEventPortNumber,
+ ogsgnlEventPortLabel }
+ DESCRIPTION
+ "The alert sent when a signal change occurs"
+ ::= 1002
+
+ -- Serial console pattern traps
+ ogPatternMibObjects OBJECT IDENTIFIER ::= { ogPatternMib 10 }
+ ogpatnEvent OBJECT IDENTIFIER ::= { ogPatternMibObjects 1 }
+ ogpatnEventTable OBJECT IDENTIFIER ::= { ogpatnEvent 1 }
+ ogpatnEventEntry OBJECT IDENTIFIER ::= { ogpatnEventTable 1 }
+
+ ogpatnEventDescription OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A description of the matches purpose"
+ ::= { ogpatnEventEntry 10 }
+
+ ogpatnEventText OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The full text which matched the pattern"
+ ::= { ogpatnEventEntry 11 }
+
+ ogpatnEventPortNumber OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Serial port number on which the pattern matched"
+ ::= { ogpatnEventEntry 12 }
+
+ ogpatnEventPortLabel OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The label for the serial port where pattern match
+ occurred"
+ ::= { ogpatnEventEntry 13 }
+
+ ogpatnEventOccurred TRAP-TYPE
+ ENTERPRISE opengear
+ VARIABLES {
+ ogpatnEventDescription,
+ ogpatnEventText,
+ ogpatnEventPortNumber,
+ ogpatnEventPortLabel }
+ DESCRIPTION
+ "The alert sent when a pre-defined pattern was
+ matched text in a consoles serial character stream"
+ ::= 1003
+
+ -- Sensor traps
+ ogSensorMibObjects OBJECT IDENTIFIER ::= { ogSensorMib 10 }
+ ogsensStatus OBJECT IDENTIFIER ::= { ogSensorMibObjects 1 }
+ ogsensStatusTable OBJECT IDENTIFIER ::= { ogsensStatus 1 }
+ ogsensStatusEntry OBJECT IDENTIFIER ::= { ogsensStatusTable 1 }
+
+ ogsensStatusName OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the device pertaining to the status event"
+ ::= { ogsensStatusEntry 10 }
+
+ ogsensStatusDevType OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The type of device pertaining to the status event"
+ ::= { ogsensStatusEntry 11 }
+
+ ogsensStatusType OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The type of sensor pertaining to the status event"
+ ::= { ogsensStatusEntry 12 }
+
+ ogsensStatusValue OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The value of the sensor pertaining to the status event"
+ ::= { ogsensStatusEntry 13 }
+
+ ogsensStatusOccurred TRAP-TYPE
+ ENTERPRISE opengear
+ VARIABLES {
+ ogsensStatusName,
+ ogsensStatusDevType,
+ ogsensStatusType,
+ ogsensStatusValue }
+ DESCRIPTION
+ "The trap sent when a sensor event occurs"
+ ::= 1004
+
+ -- Host traps
+ ogHostMibObjects OBJECT IDENTIFIER ::= { ogHostMib 10 }
+ oghostEvent OBJECT IDENTIFIER ::= { ogHostMibObjects 1 }
+ oghostEventTable OBJECT IDENTIFIER ::= { oghostEvent 1 }
+ oghostEventEntry OBJECT IDENTIFIER ::= { oghostEventTable 1 }
+
+ oghostEventUsername OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The user pertaining to the connection event"
+ ::= { oghostEventEntry 10 }
+
+ oghostEventType OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The type of connection event"
+ ::= { oghostEventEntry 11 }
+
+ oghostEventAddress OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The address of the host to which this connection applies."
+ ::= { oghostEventEntry 12 }
+
+ oghostEventDescription OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The description of the host to which this connection applies."
+ ::= { oghostEventEntry 13 }
+
+ oghostEventProtocol OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The internet protocl to which this connection applies."
+ ::= { oghostEventEntry 14 }
+
+ oghostEventPort OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The applicable port number of the host."
+ ::= { oghostEventEntry 15 }
+
+ oghostEventOccurred TRAP-TYPE
+ ENTERPRISE opengear
+ VARIABLES {
+ oghostEventUsername,
+ oghostEventType,
+ oghostEventAddress,
+ oghostEventDescription,
+ oghostEventProtocol,
+ oghostEventPort }
+ DESCRIPTION
+ "The alert sent when a user connection event occurs"
+ ::= 2001
+
+ -- Failover traps
+ ogFailoverMibObjects OBJECT IDENTIFIER ::= { ogFailoverMib 10 }
+ ogfovrEvent OBJECT IDENTIFIER ::= { ogFailoverMibObjects 1 }
+ ogfovrEventTable OBJECT IDENTIFIER ::= { ogfovrEvent 1 }
+ ogfovrEventEntry OBJECT IDENTIFIER ::= { ogfovrEventTable 1 }
+
+ ogfovrEventPrimary OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the network interface which failed"
+ ::= { ogfovrEventEntry 10 }
+
+ ogfovrEventSecondary OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the network interface which was connected
+ instead"
+ ::= { ogfovrEventEntry 11 }
+
+ ogfovrEventOccurred TRAP-TYPE
+ ENTERPRISE opengear
+ VARIABLES { ogfovrEventPrimary, ogfovrEventSecondary }
+ DESCRIPTION
+ "The alert sent when a network failover event occurs"
+ ::= 2002
+
+ -- Ups trap
+ ogNetUpsMibObjects OBJECT IDENTIFIER ::= { ogNetUpsMib 10 }
+ ognupsEvent OBJECT IDENTIFIER ::= { ogNetUpsMibObjects 1 }
+ ognupsEventTable OBJECT IDENTIFIER ::= { ognupsEvent 1 }
+ ognupsEventEntry OBJECT IDENTIFIER ::= { ognupsEventTable 1 }
+
+ ognupsEventName OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the UPS pertaining to the status event"
+ ::= { ognupsEventEntry 10 }
+
+ ognupsEventType OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The type of status event"
+ ::= { ognupsEventEntry 11 }
+
+ ognupsEventOccurred TRAP-TYPE
+ ENTERPRISE opengear
+ VARIABLES {
+ ognupsEventName,
+ ognupsEventType }
+ DESCRIPTION
+ "The alert sent when a UPS status event occurs"
+ ::= 2003
+
+ -- Data Usage trap
+ ogDataMibObjects OBJECT IDENTIFIER ::= { ogDataMib 10 }
+ ogdataEvent OBJECT IDENTIFIER ::= { ogDataMibObjects 1 }
+ ogdataEventTable OBJECT IDENTIFIER ::= { ogdataEvent 1 }
+ ogdataEventEntry OBJECT IDENTIFIER ::= { ogdataEventTable 1 }
+
+ ogdataEventBytes OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The amount of bytes which triggers this usage alert"
+ ::= { ogdataEventEntry 10 }
+
+ ogdataEventSeconds OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The time in seconds over which bytes are measured"
+ ::= { ogdataEventEntry 11 }
+
+ ogdataEventDevice OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The ID for the interface thos pertains to"
+ ::= { ogdataEventEntry 12 }
+
+ ogdataEventState OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Whether data usage alert is on (1) or off (0)"
+ ::= { ogdataEventEntry 13 }
+
+ ogdataEventOccurred TRAP-TYPE
+ ENTERPRISE opengear
+ VARIABLES {
+ ogdataEventBytes,
+ ogdataEventSeconds,
+ ogdataEventDevice,
+ ogdataEventState }
+ DESCRIPTION
+ "The trap sent when a data usage alert occurs"
+ ::= 2004
+
+END