| -rw-r--r-- | MIBS/orvaldi/companyMIB | 2762 |
1 files changed, 2762 insertions, 0 deletions
diff --git a/MIBS/orvaldi/companyMIB b/MIBS/orvaldi/companyMIB new file mode 100644 index 0000000..1ec1838 --- /dev/null +++ b/MIBS/orvaldi/companyMIB @@ -0,0 +1,2762 @@ +-- company power MIB + +-- +-- { iso org(3) dod(6) internet(1) private(4) enterprises(1) company(2111) +-- products(1) ups(1) +-- +-- ============================================================================================== + + +companyMIB DEFINITIONS ::= BEGIN + +IMPORTS + enterprises + FROM RFC1155-SMI + MODULE-IDENTITY, OBJECT-TYPE, OBJECT-IDENTITY + FROM SNMPv2-SMI + DisplayString + FROM SNMPv2-TC + TRAP-TYPE + FROM RFC-1215 + PositiveInteger, NonNegativeInteger + FROM UPS-MIB; + + + companyMIB MODULE-IDENTITY + LAST-UPDATED "201005060000Z" + ORGANIZATION "company Power Technology" + CONTACT-INFO " " + + DESCRIPTION + "The MIB module to describe UPS" + + + + ::= { enterprises 21111 } + + + +products OBJECT IDENTIFIER ::= { companyMIB 1 } +ups OBJECT IDENTIFIER ::= { products 1 } +inverter OBJECT IDENTIFIER ::= { products 2 } +charger OBJECT IDENTIFIER ::= { products 3 } +ATS OBJECT IDENTIFIER ::= { products 4 } + +upsIdent OBJECT IDENTIFIER ::= { ups 1 } +upsRating OBJECT IDENTIFIER ::= { ups 2 } +upsBattery OBJECT IDENTIFIER ::= { ups 3 } +upsInput OBJECT IDENTIFIER ::= { ups 4 } +upsOutput OBJECT IDENTIFIER ::= { ups 5 } +upsBypass OBJECT IDENTIFIER ::= { ups 6 } +upsTest OBJECT IDENTIFIER ::= { ups 7 } +upsControl OBJECT IDENTIFIER ::= { ups 8 } +agentConfig OBJECT IDENTIFIER ::= { ups 9 } +commConfig OBJECT IDENTIFIER ::= { ups 10 } +upsConfig OBJECT IDENTIFIER ::= { ups 11 } +upsTraps OBJECT IDENTIFIER ::= { ups 12 } +extend OBJECT IDENTIFIER ::= { ups 13 } + +solarIdent OBJECT IDENTIFIER ::= { inverter 1 } +solarRating OBJECT IDENTIFIER ::= { inverter 2 } +solarBattery OBJECT IDENTIFIER ::= { inverter 3 } +solarGrid OBJECT IDENTIFIER ::= { inverter 4 } +solarACOutput OBJECT IDENTIFIER ::= { inverter 5 } +solarPV OBJECT IDENTIFIER ::= { inverter 6 } +solarEnergy OBJECT IDENTIFIER ::= { inverter 7 } +solarTest OBJECT IDENTIFIER ::= { inverter 8 } +solarDefValue OBJECT IDENTIFIER ::= { inverter 9 } +solarFaultInfo OBJECT IDENTIFIER ::= { inverter 10 } +solarControl OBJECT IDENTIFIER ::= { inverter 11 } +solarAgentConfig OBJECT IDENTIFIER ::= { inverter 12 } +solarCommConfig OBJECT IDENTIFIER ::= { inverter 13 } +solarConfig OBJECT IDENTIFIER ::= { inverter 14 } +solarTraps OBJECT IDENTIFIER ::= { inverter 15 } +solarExtend OBJECT IDENTIFIER ::= { inverter 16 } + + +ATSIdent OBJECT IDENTIFIER ::= { ATS 1 } +ATSRating OBJECT IDENTIFIER ::= { ATS 2 } +ATSInformation OBJECT IDENTIFIER ::= { ATS 3 } +ATSControl OBJECT IDENTIFIER ::= { ATS 4 } +ATSAgentConfig OBJECT IDENTIFIER ::= { ATS 5 } +ATSCommConfig OBJECT IDENTIFIER ::= { ATS 6 } +ATSConfig OBJECT IDENTIFIER ::= { ATS 7 } +ATSTraps OBJECT IDENTIFIER ::= { ATS 8 } +ATSExtend OBJECT IDENTIFIER ::= { ATS 9 } + +---======================================================= +---upsIdent +--- prefix =upsId +---======================================================== + +upsIdManufacturer OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..31)) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The name of the UPS manufacturer." + ::= { upsIdent 1 } + +upsIdProtocol OBJECT-TYPE + SYNTAX INTEGER { + unknown(-1), + pmv(99), + p00(0), + p01(1), + p02(2), + p03(3), + p04(4), + p05(5), + p06(6), + p07(7), + p08(8), + p09(9), + p10(10), + sec(80) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The UPS Protocol id." + ::= { upsIdent 2 } + +upsIdModelName OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..15)) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The UPS Model designation." + ::= { upsIdent 3 } + +upsIdSerialNumber OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..31)) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The UPS serial no." + ::= { upsIdent 4 } + +upsIdName OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..31)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "A string identifying the UPS. This object should be + set by the administrator." + ::= { upsIdent 5 } + +upsIdFWVersion OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..31)) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Main CPU firmware version." + ::= { upsIdent 6 } + + +upsIdUPSType OBJECT-TYPE + SYNTAX INTEGER { + standy(0), + line-interactive(1), + on-line(2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "UPS type." + ::= { upsIdent 7 } +--=========================================================================== +--upsRating +--prefix =upsRat +--the rating info of ups +--========================================================================== +upsRatinVoltage OBJECT-TYPE + SYNTAX NonNegativeInteger + UNITS "0.1 Volt DC" + ACCESS read-only + STATUS current + DESCRIPTION + "The rating input voltage of UPS" + ::= { upsRating 1 } + +upsRatoutVoltage OBJECT-TYPE + SYNTAX NonNegativeInteger + UNITS "0.1 Volt DC" + ACCESS read-only + STATUS current + DESCRIPTION + "The rating output voltage of UPS" + ::= { upsRating 2 } + +upsRatoutFrequency OBJECT-TYPE + SYNTAX NonNegativeInteger + UNITS "0.1 HZ" + ACCESS read-only + STATUS current + DESCRIPTION + "The rating output frequency of UPS" + ::= { upsRating 3 } + +upsRatoutCurrent OBJECT-TYPE + SYNTAX NonNegativeInteger + UNITS "0.1 Amp DC" + ACCESS read-only + STATUS current + DESCRIPTION + "The rating output current of UPS" + ::= { upsRating 4 } + +upsRatoutApparentPower OBJECT-TYPE + SYNTAX NonNegativeInteger + UNITS "0.1 VA" + ACCESS read-only + STATUS current + DESCRIPTION + "The rating output apparent power of UPS" + ::= { upsRating 5 } + +upsRatoutTruePower OBJECT-TYPE + SYNTAX NonNegativeInteger + UNITS "0.1 Wt" + ACCESS read-only + STATUS current + DESCRIPTION + "The rating output true power of UPS" + ::= { upsRating 6 } + +upsRatBatVoltage OBJECT-TYPE + SYNTAX NonNegativeInteger + UNITS "0.1 vol" + ACCESS read-only + STATUS current + DESCRIPTION + "The rating battery voltage of UPS" + ::= { upsRating 7 } + + + +-- =========================================================================== +-- upsBattery +-- prefix = upsBat +-- The Battery group. +-- est=estimated +-- =========================================================================== + +upsBatStatus OBJECT-TYPE + SYNTAX INTEGER { + unknown(1), + batteryNormal(2), + batteryLow(3), + batteryDepleted(4), + batteryDischarging(5), + batteryFailure(6), + batteryReplace(7), + batterysilence(8) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The indication of the status in the UPS system's batteries." + ::= { upsBattery 1 } + + + +upsBatSecondsOnBattery OBJECT-TYPE + SYNTAX INTEGER + UNITS "seconds" + ACCESS read-only + STATUS current + DESCRIPTION + "If the unit is on battery power, the elapsed time + since the UPS last switched to battery power, or the + time since the network management subsystem was last + restarted, whichever is less. -1 shall be returned + if the unit is not on battery power." + ::= { upsBattery 2 } + +upsBatEstMinutesRemaining OBJECT-TYPE + SYNTAX INTEGER + UNITS "minutes" + ACCESS read-only + STATUS current + DESCRIPTION + "An estimate of the time to battery charge depletion + under the present load conditions if the utility power + is off and remains off, or if it were to be lost and + remain off." + ::= { upsBattery 3 } + +upsBatEstChargeRemaining OBJECT-TYPE + SYNTAX INTEGER (0..100) + UNITS "percent" + ACCESS read-only + STATUS current + DESCRIPTION + "An estimate of the battery charge remaining expressed + as a percent of full charge." + ::= { upsBattery 4 } + +upsBatPBatVoltage OBJECT-TYPE + SYNTAX NonNegativeInteger + UNITS "0.1 Volt DC" + ACCESS read-only + STATUS current + DESCRIPTION + "The magnitude of the present Positive battery voltage." + ::= { upsBattery 5 } + + +upsBatNBatVoltage OBJECT-TYPE + SYNTAX NonNegativeInteger + UNITS "0.1 Volt DC" + ACCESS read-only + STATUS current + DESCRIPTION + "The magnitude of the present negative battery voltage." + ::= { upsBattery 6 } + +upsBatPBatCurrent OBJECT-TYPE + SYNTAX INTEGER + UNITS "0.1 Amp DC" + ACCESS read-only + STATUS current + DESCRIPTION + "The positive battery present current." + ::= { upsBattery 7 } + +upsBatNBatCurrent OBJECT-TYPE + SYNTAX INTEGER + UNITS "0.1 Amp DC" + ACCESS read-only + STATUS current + DESCRIPTION + "The present negative battery current." + ::= { upsBattery 8 } + +upsBatPBatChargCurrent OBJECT-TYPE + SYNTAX INTEGER + UNITS "0.1 Amp DC" + ACCESS read-only + STATUS current + DESCRIPTION + "The Positive battery charging current." + ::= { upsBattery 9 } + +upsBatNBatchargCurrent OBJECT-TYPE + SYNTAX INTEGER + UNITS "0.1 Amp DC" + ACCESS read-only + STATUS current + DESCRIPTION + "The present negative battery charging current." + ::= { upsBattery 10 } + +upsBatPBatDischargCurrent OBJECT-TYPE + SYNTAX INTEGER + UNITS "0.1 Amp DC" + ACCESS read-only + STATUS current + DESCRIPTION + "The present positive battery discharging current." + ::= { upsBattery 11 } + +upsBatNBatDischargCurrent OBJECT-TYPE + SYNTAX INTEGER + UNITS "0.1 Amp DC" + ACCESS read-only + STATUS current + DESCRIPTION + "The present negative battery discharging current." + ::= { upsBattery 12 } + +upsBatTemperature OBJECT-TYPE + SYNTAX INTEGER + UNITS "degrees 0.1 Centigrade" + ACCESS read-only + STATUS current + DESCRIPTION + "The ambient temperature at or near the UPS Battery + casing." + ::= { upsBattery 13 } + +upsBatNumberInSeries OBJECT-TYPE + SYNTAX PositiveInteger + ACCESS read-only + STATUS current + DESCRIPTION + "The number of battery in series." + ::= { upsBattery 14 } + + +upsBatNumberInParallel OBJECT-TYPE + SYNTAX PositiveInteger + ACCESS read-only + STATUS current + DESCRIPTION + "The number of battery in Parallel." + ::= { upsBattery 15 } + +upsBatPBatDischargCurrent2 OBJECT-TYPE + SYNTAX INTEGER + UNITS "0.1 Amp DC" + ACCESS read-only + STATUS current + DESCRIPTION + "The present positive battery pipe2 discharging current." + ::= { upsBattery 16 } + +-- =========================================================================== +-- upsInput +-- prefix = upsIn +-- Input group. +-- =========================================================================== + +upsInLineBads OBJECT-TYPE + SYNTAX NonNegativeInteger + ACCESS read-only + STATUS current + DESCRIPTION + "A count of the number of times the input entered an + out-of-tolerance condition as defined by the + manufacturer. This count is incremented by one each + time the input transitions from zero out-of-tolerance + lines to one or more input lines out-of-tolerance." + ::= { upsInput 1 } + + +upsInTtlApparentPower OBJECT-TYPE + SYNTAX NonNegativeInteger + UNITS "0.1VA" + ACCESS read-only + STATUS current + DESCRIPTION + "Total input apparent power ." + ::= { upsInput 2 } + +upsInTtlTruePower OBJECT-TYPE + SYNTAX NonNegativeInteger + UNITS "0.1WT" + ACCESS read-only + STATUS current + DESCRIPTION + "Total input active(true) power ." + ::= { upsInput 3 } + + + +upsInNumLines OBJECT-TYPE + SYNTAX NonNegativeInteger + ACCESS read-only + STATUS current + DESCRIPTION + "The number of input lines utilized in this device. + This variable indicates the number of rows in the + input table." + ::= { upsInput 4 } + + +upsInTable OBJECT-TYPE + SYNTAX SEQUENCE OF UpsInEntry + ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of input table entries. The number of entries + is given by the value of upsInputNumLines." + ::= { upsInput 5 } + + +upsInTtlVoltage OBJECT-TYPE + SYNTAX INTEGER + UNITS "0.1 Volts" + ACCESS read-only + STATUS current + DESCRIPTION + "The input utility line tatol voltage ." + ::= { upsInput 6 } + +upsInTtlCurrent OBJECT-TYPE + SYNTAX INTEGER + UNITS "0.1 A" + ACCESS read-only + STATUS current + DESCRIPTION + "The input utility line tatol current." + ::= { upsInput 7 } + +upsInEntry OBJECT-TYPE + SYNTAX UpsInEntry + ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing information applicable to a + particular input line." + INDEX { upsInLineIndex } + ::= { upsInTable 1 } + +UpsInEntry ::= + SEQUENCE { + upsInLineIndex PositiveInteger, + upsInFrequency NonNegativeInteger, + upsInVoltage NonNegativeInteger, + upsInCurrent NonNegativeInteger, + upsInApparentPower NonNegativeInteger, + upsInTruePower NonNegativeInteger, + upsInPowerFactor NonNegativeInteger, + upsInLineVoltage NonNegativeInteger + } + +upsInLineIndex OBJECT-TYPE + SYNTAX INTEGER (0..10) + ACCESS read-only + STATUS current + DESCRIPTION + "The number of output lines" + ::= { upsInEntry 1 } + +upsInFrequency OBJECT-TYPE + SYNTAX NonNegativeInteger + UNITS "0.1 Hertz" + ACCESS read-only + STATUS current + DESCRIPTION + "The present input frequency." + ::= { upsInEntry 2 } + +upsInVoltage OBJECT-TYPE + SYNTAX INTEGER + UNITS "0.1 Volts" + ACCESS read-only + STATUS current + DESCRIPTION + "The input utility line voltage ." + ::= { upsInEntry 3 } + +upsInCurrent OBJECT-TYPE + SYNTAX INTEGER + UNITS "0.1Amp" + ACCESS read-only + STATUS current + DESCRIPTION + "The magnitude of the present input current " + ::= { upsInEntry 4 } + + + +upsInApparentPower OBJECT-TYPE + SYNTAX NonNegativeInteger + UNITS "0.1VA" + ACCESS read-only + STATUS current + DESCRIPTION + "The magnitude of the present input Apparent power." + ::= { upsInEntry 5 } + + +upsInTruePower OBJECT-TYPE + SYNTAX NonNegativeInteger + UNITS "0.1Watts" + ACCESS read-only + STATUS current + DESCRIPTION + "The magnitude of the present input true power." + ::= { upsInEntry 6 } + + + +upsInPowerFactor OBJECT-TYPE + SYNTAX NonNegativeInteger + UNITS "0.01" + ACCESS read-only + STATUS current + DESCRIPTION + "Input true power/apparent power factor " + ::= { upsInEntry 7 } + +upsInLineVoltage OBJECT-TYPE + SYNTAX INTEGER + UNITS "0.1 Volts" + ACCESS read-only + STATUS current + DESCRIPTION + "The input utility line voltage . + if upsInLineIndex =1, upsInLineVoltage = Line voltage of RS phase; + if upsInLineIndex =2, upsInLineVoltage = Line voltage of ST phase; + if upsInLineIndex =3, upsInLineVoltage = Line voltage of TR phase." + ::= { upsInEntry 8 } + +-- =========================================================================== +-- upsOutput +-- prefix= upsOut +-- Output group +-- =========================================================================== + +upsOutSource OBJECT-TYPE + SYNTAX INTEGER { + other(1), + none(2), + normal(3), + bypass(4), + battery(5), + booster(6), + reducer(7), + batterytest(8), + fault(9), + HE-ECOmode(10), + convertermode(11) + } + ACCESS read-only + STATUS current + DESCRIPTION + "The present source of output power. The enumeration + none(2) indicates that there is no source of output + power (and therefore no output power), for example, + the system has opened the output breaker.==UPS standby mode" + ::= { upsOutput 1 } + +upsOutFrequency OBJECT-TYPE + SYNTAX INTEGER + UNITS "0.1 Hertz" + ACCESS read-only + STATUS current + DESCRIPTION + "The current output frequency of the UPS system " + ::= { upsOutput 2 } + + +upsOutTtlApparentPower OBJECT-TYPE + SYNTAX NonNegativeInteger + UNITS "0.1VA" + ACCESS read-only + STATUS current + DESCRIPTION + "Total output apparent power ." + ::= { upsOutput 3 } + +upsOutTtlTruePower OBJECT-TYPE + SYNTAX NonNegativeInteger + UNITS "0.1Watts" + ACCESS read-only + STATUS current + DESCRIPTION + "Total output active(true) power ." + ::= { upsOutput 4 } + + +upsOutTtlPercentLoad OBJECT-TYPE + SYNTAX INTEGER (0..100) + UNITS "percent" + ACCESS read-only + STATUS current + DESCRIPTION + "The percentage of the UPS power capacity presently + being used on this output line, i.e., the greater of + the percent load of true power capacity and the + percent load of VA." + ::= { upsOutput 5 } + + + + +upsOutNumLines OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS current + DESCRIPTION + "The number of output lines utilized in this device. + This variable indicates the number of rows in the + output table." + ::= { upsOutput 6 } + +upsOutTable OBJECT-TYPE + SYNTAX SEQUENCE OF UpsOutEntry + ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of output table entries. The number of + entries is given by the value of upsOutputNumLines." + ::= { upsOutput 7 } + + +upsOutTtlVoltage OBJECT-TYPE + SYNTAX INTEGER + UNITS "0.1vot" + ACCESS read-only + STATUS current + DESCRIPTION + "Total output voltage ." + ::= { upsOutput 8 } + +upsOutTtlCurrent OBJECT-TYPE + SYNTAX INTEGER + UNITS "0.1A" + ACCESS read-only + STATUS current + DESCRIPTION + "Total output current." + ::= { upsOutput 9 } + +upsOutStatus OBJECT-TYPE + SYNTAX DisplayString (SIZE (4..4)) + ACCESS read-only + STATUS current + DESCRIPTION + " For HVDC device. + char status[4]; + status[0]status[1]:00, no output1; 01, line output1; 02, bat output1 + status[2]status[3]:00, no output2; 01, line output2; 02, bat output2 + " + ::= { upsOutput 10 } + + + +upsOutSource2 OBJECT-TYPE + SYNTAX INTEGER { + other(1), + none(2), + normal(3), + bypass(4), + battery(5), + booster(6), + reducer(7), + batterytest(8), + fault(9), + HE-ECOmode(10), + convertermode(11) + } + ACCESS read-only + STATUS current + DESCRIPTION + "For HVDC(protocol:P12) machine. The present source of output power. The enumeration + none(2) indicates that there is no source of output + power (and therefore no output power), for example, + the system has opened the output breaker.==UPS standby mode" + ::= { upsOutput 11 } + + +upsOutEntry OBJECT-TYPE + SYNTAX UpsOutEntry + ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing information applicable to a + particular output line." + INDEX { upsOutLineIndex } + ::= { upsOutTable 1 } + +UpsOutEntry ::= + SEQUENCE { + upsOutLineIndex PositiveInteger, + upsOutVoltage NonNegativeInteger, + upsOutCurrent NonNegativeInteger, + upsOutApparentPower NonNegativeInteger, + upsOutTruePower NonNegativeInteger, + upsOutPowerFactor NonNegativeInteger, + upsOutPercentLoad INTEGER, + upsOutLineVoltage NonNegativeInteger + } + +upsOutLineIndex OBJECT-TYPE + SYNTAX INTEGER (0..10) + ACCESS read-only + STATUS current + DESCRIPTION + "The output line identifier." + ::= { upsOutEntry 1 } + +upsOutVoltage OBJECT-TYPE + SYNTAX INTEGER + UNITS "0.1 Volts" + ACCESS read-only + STATUS current + DESCRIPTION + "The output voltage of the UPS system." + ::= { upsOutEntry 2 } + +upsOutCurrent OBJECT-TYPE + SYNTAX INTEGER + UNITS "0.1 Amp" + ACCESS read-only + STATUS current + DESCRIPTION + "The output current of the UPS system" + ::= { upsOutEntry 3 } + +upsOutApparentPower OBJECT-TYPE + SYNTAX NonNegativeInteger + UNITS "0.1VA" + ACCESS read-only + STATUS current + DESCRIPTION + "The present output apparent power." + ::= { upsOutEntry 4 } + +upsOutTruePower OBJECT-TYPE + SYNTAX NonNegativeInteger + UNITS "0.1Watts" + ACCESS read-only + STATUS current + DESCRIPTION + "The present output true power." + ::= { upsOutEntry 5 } + +upsOutPowerFactor OBJECT-TYPE + SYNTAX NonNegativeInteger + UNITS "0.01" + ACCESS read-only + STATUS current + DESCRIPTION + "Output true power/apparent power factor " + ::= { upsOutEntry 6 } + +upsOutPercentLoad OBJECT-TYPE + SYNTAX INTEGER (0..100) + UNITS "percent" + ACCESS read-only + STATUS current + DESCRIPTION + "The percentage of the UPS power capacity presently + being used on this output line, i.e., the greater of + the percent load of true power capacity and the + percent load of VA." + ::= { upsOutEntry 7 } + +upsOutLineVoltage OBJECT-TYPE + SYNTAX INTEGER + UNITS "0.1 Volts" + ACCESS read-only + STATUS current + DESCRIPTION + "The output line voltage of the UPS system. + if upsOutLineIndex =1, upsOutLineVoltage = Line voltage of RS phase; + if upsOutLineIndex =2, upsOutLineVoltage = Line voltage of ST phase; + if upsOutLineIndex =3, upsOutLineVoltage = Line voltage of TR phase." + ::= { upsOutEntry 8 } + +upsOutFrequency OBJECT-TYPE + SYNTAX NonNegativeInteger + UNITS "0.1Hertz" + ACCESS read-only + STATUS current + DESCRIPTION + "The present output frequency." + ::= { upsOutEntry 9 } + +-- =========================================================================== +-- upsBypass +-- prefix =upsBy +-- =========================================================================== + +upsByFrequency OBJECT-TYPE + SYNTAX INTEGER + UNITS "0.1 Hertz" + ACCESS read-only + STATUS current + DESCRIPTION + "The present bypass frequency." + ::= { upsBypass 1 } + + + +upsByNumLines OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS current + DESCRIPTION + "The number of bypass lines utilized in this device. + This entry indicates the number of rows in the bypass + table." + ::= { upsBypass 2 } + + +upsByTable OBJECT-TYPE + SYNTAX SEQUENCE OF UpsByEntry + ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of bypass table entries. The number of + entries is given by the value of upsBypassNumLines." + ::= { upsBypass 3 } + +upsByEntry OBJECT-TYPE + SYNTAX UpsByEntry + ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing information applicable to a + particular bypass input." + INDEX { upsByLineIndex } + ::= { upsByTable 1 } + +UpsByEntry ::= + SEQUENCE { + upsByLineIndex PositiveInteger, + upsByVoltage NonNegativeInteger, + upsByCurrent NonNegativeInteger, + upsByPower NonNegativeInteger, + upsByLineVoltage INTEGER + } + +upsByLineIndex OBJECT-TYPE + SYNTAX INTEGER (0..65535) + ACCESS read-only + STATUS current + DESCRIPTION + "The bypass line identifier." + ::= { upsByEntry 1 } + +upsByVoltage OBJECT-TYPE + SYNTAX INTEGER + UNITS "0.1 Volts" + ACCESS read-only + STATUS current + DESCRIPTION + "The present bypass voltage." + ::= { upsByEntry 2 } + +upsByCurrent OBJECT-TYPE + SYNTAX INTEGER + UNITS "0.1 RMS Amp" + ACCESS read-only + STATUS current + DESCRIPTION + "The present bypass current." + ::= { upsByEntry 3 } + +upsByPower OBJECT-TYPE + SYNTAX NonNegativeInteger + UNITS "0.1Watts" + ACCESS read-only + STATUS current + DESCRIPTION + "The present true power conveyed by the bypass." + ::= { upsByEntry 4 } + +upsByLineVoltage OBJECT-TYPE + SYNTAX INTEGER + UNITS "0.1 Volts" + ACCESS read-only + STATUS current + DESCRIPTION + "The present bypass line voltage. + if upsByLineIndex=1,upsByLineVoltage=Line voltage of RS phase; + if upsByLineIndex=2,upsByLineVoltage=Line voltage of ST phase; + if upsByLineIndex=3,upsByLineVoltage=Line voltage of TR phase." + ::= { upsByEntry 5 } + +-- =========================================================================== +-- upsTest +-- prefix=upsTst +-- =========================================================================== + + +upsTstBatteryTest OBJECT-TYPE + SYNTAX INTEGER { + none(1), + battTest10sec(2), + battTestUntilLow(3), + battTestWithTime(4), + battTestCancelTest(5), + battTestClearInfo(6) + + } + ACCESS read-write + STATUS current + DESCRIPTION + "This object specify the battery test type and initiate + battery test. If battTestWithTime selected, the test + time is refer to upsTestBatteryTestTime." + ::= { upsTest 1 } + +upsTstBatteryTestResult OBJECT-TYPE + SYNTAX INTEGER { + donePassed(1), + doneWarning(2), + doneError(3), + aborted(4), + inProgress(5), + noTestsInitiated(6) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The results of the current or last UPS diagnostics + test performed. The values for donePassed(1), + doneWarning(2), and doneError(3) indicate that the + test completed either successfully, with a warning, or + with an error, respectively. The value aborted(4) is + returned for tests which are aborted by setting the + value of upsTestId to upsTestAbortTestInProgress. + Tests which have not yet concluded are indicated by + inProgress(5). The value noTestsInitiated(6) + indicates that no previous test results are available, + such as is the case when no tests have been run since + the last reinitialization of the network management + subsystem and the system has no provision for non- + volatile storage of test results." + ::= { upsTest 2 } + + + +upsTstBatteryTestStartTime OBJECT-TYPE + SYNTAX DisplayString (SIZE(19..19)) + ACCESS read-only + STATUS current + DESCRIPTION + "The value of the time the test in progress was initiated, + or, if no test is in progress, the time the previous test + was initiated. If the value of upsTestBatteryTestResult + is noTestsInitiated(6), upsTestStartTime has the value + 01/01/1970 00:00:00. format is (MM/DD/YYYY hh:mm:ss)" + ::= { upsTest 3 } + + +upsTstBatterySettingTime OBJECT-TYPE + SYNTAX INTEGER (12..5940) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The object specify the test time for battery test, the unit is seconds" + ::= { upsTest 4 } + + --below 1 minute 0.2-1.0 ,larger than 1 minutes ,1,2,3..99; + +-- =========================================================================== +-- upsControl +-- prefix=upsCtl +-- =========================================================================== + + +upsCtlShutdownDelay OBJECT-TYPE + SYNTAX INTEGER (-2..2147483648) + UNITS "seconds" + ACCESS read-write + STATUS current + DESCRIPTION + "The delay in seconds the UPS remains on after being told + to turn off. if value=-2 cancel shutdown, if value=-1 donothing, + value=0 shutdown ups immediately" + ::= { upsControl 1 } + + +upsCtlSleepTime OBJECT-TYPE + SYNTAX INTEGER (-1..2147483648) + UNITS "minutes" + ACCESS read-write + STATUS current + DESCRIPTION + "The time in minutes for the UPS to go to sleep when + instructed. When in sleep mode, the UPS will not provide + output power regardless of the input line state. Once the + specified time has elapsed, output power will be restored. + + This is a configuration setting. The UPS will not go to + sleep until told to do so by the manager from a management + station. + + Any input value is allowed, however the UPS only recognizes + 0 - 9999 minutes in one minute increments. + + If the provided value is higher than the highest acceptable + value, the highest acceptable value is used." + ::= { upsControl 2 } + +upsCtlStartupAfterDelay OBJECT-TYPE + SYNTAX INTEGER (-1..2147483648) + UNITS "seconds" + ACCESS read-write + STATUS current + DESCRIPTION + "Setting this object will start the output after the + indicated number of seconds, including starting the + UPS, if necessary. -1 mean not startup. + must set upsCtlStartupAfterDelay before upsCtlShutdownDelay , + the value must larger than 59 if the value not equal -1 " + + ::= { upsControl 3 } + + + +upsCtlbuzzer OBJECT-TYPE + SYNTAX INTEGER { + on(1), + off(2) + } + ACCESS read-write + STATUS current + DESCRIPTION + "Setting this object to 'on' or 'off' to enable or disable buzzer" + + ::= { upsControl 4 } + + + +upsCtlRemoteControlUPS OBJECT-TYPE + SYNTAX INTEGER { + on(1), + off(2) + } + ACCESS read-write + STATUS current + DESCRIPTION + "Setting this object to turn 'on' or 'off' UPS " + + ::= { upsControl 5 } + +upsCtloutletPoweron OBJECT-TYPE + SYNTAX INTEGER (1..2) + ACCESS write-only + STATUS current + DESCRIPTION + "Setting this object to 1 means 1st outlet,2 means 2nd outlet , immediately process" + + ::= { upsControl 6 } + + + +upsCtloutletPoweroff OBJECT-TYPE + SYNTAX INTEGER (1..2) + ACCESS write-only + STATUS current + DESCRIPTION + "Setting this object to 1 means 1st outlet, + 2 means 2nd outlet , immediately process" + + ::= { upsControl 7 } + + +upsCtlOutlet1Powerofftime OBJECT-TYPE + SYNTAX INTEGER (-1..999) + ACCESS read-write + STATUS current + DESCRIPTION + "setting this object to -1 means this control not effect, + 0 means immediately process, + >0 means wait times unit is minutes + use in battery mode" + ::= { upsControl 8 } + +upsCtlOutlet2Powerofftime OBJECT-TYPE + SYNTAX INTEGER (-1..999) + ACCESS read-write + STATUS current + DESCRIPTION + "setting this object to -1 means this control not effect, + 0 means immediately process , + >0 means wait times unit is minutes .use in battery mode" + ::= { upsControl 9 } + +upsCtlResetConfigure OBJECT-TYPE + SYNTAX INTEGER { + none(0), + reset(1) + } + ACCESS read-write + STATUS current + DESCRIPTION + " reset all configure para to default." + ::= { upsControl 10 } + + +--=========================================================================== +-- +-- agentConfig +-- prefix=agent +-- =========================================================================== + + +agentConfigDatetime OBJECT-TYPE + SYNTAX DisplayString (SIZE (19..19)) + ACCESS read-write + STATUS current + DESCRIPTION + "The datetime in agent, format is (MM/DD/YYYY hh:mm:ss)" + ::= { agentConfig 1 } + + + + +---====================================================================== +-- commConfig +-- prefix =comm +---====================================================================== + +commBaudRate OBJECT-TYPE + SYNTAX INTEGER { + B1200(1), + B2400(2), + B4800(3), + B9600(4), + B19200(5) + } + ACCESS read-write + STATUS current + DESCRIPTION + "The UPS communicate baudrate" + ::= { commConfig 1 } + + + +commDatabits OBJECT-TYPE + SYNTAX INTEGER (8..9) + + ACCESS read-write + STATUS current + DESCRIPTION + "The UPS communicate data bits" + ::= { commConfig 2 } + + +commStopbits OBJECT-TYPE + SYNTAX INTEGER (1..2) + ACCESS read-write + STATUS current + DESCRIPTION + "The UPS communicate stop bits " + + ::= { commConfig 3 } + +commParity OBJECT-TYPE + SYNTAX INTEGER { + none(0), + odd(1), + even(2) + } + ACCESS read-write + STATUS current + DESCRIPTION + "The UPS communicate Parity " + ::= { commConfig 4 } + +commTimeout OBJECT-TYPE + SYNTAX INTEGER (100..1000) + ACCESS read-write + STATUS current + DESCRIPTION + "The UPS communicate timeout" + ::= { commConfig 5 } + + +--=========================================================================== +-- +-- upsConfig +--prefix=upsCfg +-- =========================================================================== + +upsCfgAlarmbypass OBJECT-TYPE + SYNTAX INTEGER { + disable(0), + enable(1), + notsupport(2) + + } + ACCESS read-write + STATUS current + DESCRIPTION + "Setting this object enable /disable alarm bypass mode" + + ::= { upsConfig 1 } + +upsCfgAlarmbattery OBJECT-TYPE + SYNTAX INTEGER { + disable(0), + enable(1), + notsupport(2) + } + ACCESS read-write + STATUS current + DESCRIPTION + "Setting this object enable/disable alarm battery mode" + + ::= { upsConfig 2 } + +upsCfgAutoReboot OBJECT-TYPE + SYNTAX INTEGER { + disable(0), + enable(1), + notsupport(2) + } + ACCESS read-write + STATUS current + DESCRIPTION + "Setting this object enable/disable auto reboot" + ::= { upsConfig 3 } + + +upsCfgBypasswhenupsoff OBJECT-TYPE + SYNTAX INTEGER { + disable(0), + enable(1), + notsupport(2) + } + ACCESS read-write + STATUS current + DESCRIPTION + "Setting this object start/stop bypass when ups off" + ::= { upsConfig 4 } + + +upsCfgBatterDDP OBJECT-TYPE + SYNTAX INTEGER { + disable(0), + enable(1), + notsupport(2) + } + ACCESS read-write + STATUS current + DESCRIPTION + "Setting this object to enable/disable battery deep-discharge protection" + ::= { upsConfig 5 } + + + + +upsCfgConvertermode OBJECT-TYPE + SYNTAX INTEGER { + disable(0), + enable(1), + notsupport(2) + } + ACCESS read-write + STATUS current + DESCRIPTION + "Setting this object to enable/disable converter mode " + + ::= { upsConfig 6 } + + +upsCfgECOmode OBJECT-TYPE + SYNTAX INTEGER { + disable(0), + enable(1), + notsupport(2) + } + ACCESS read-write + STATUS current + DESCRIPTION + "Setting this object to enable/disable ECO mode" + ::= { upsConfig 7 } + + + +upsCfgAdvanceECOmode OBJECT-TYPE + SYNTAX INTEGER { + disable(0), + enable(1), + notsupport(2) + } + ACCESS read-write + STATUS current + DESCRIPTION + "Setting this object to enable/disable advance ECO mode" + ::= { upsConfig 8 } + + +upsCfgGreenPowerFunction OBJECT-TYPE + SYNTAX INTEGER { + disable(0), + enable(1), + notsupport(2) + } + ACCESS read-write + STATUS current + DESCRIPTION + "Setting this object to enable/disable green power function" + ::= { upsConfig 9 } + + + + +upsCfgBatteryOSC OBJECT-TYPE + SYNTAX INTEGER { + disable(0), + enable(1), + notsupport(2) + } + ACCESS read-write + STATUS current + DESCRIPTION + "Setting this object to enable/disable battery open status check" + ::= { upsConfig 10 } + + +upsCfgAllowShort3times OBJECT-TYPE + SYNTAX INTEGER { + disable(0), + enable(1), + notsupport(2) + } + ACCESS read-write + STATUS current + DESCRIPTION + "Setting this object to enable/disable short 3 times" + ::= { upsConfig 11 } + + + +upsCfgColdstart OBJECT-TYPE + SYNTAX INTEGER { + disable(0), + enable(1), + notsupport(2) + + } + ACCESS read-write + STATUS current + DESCRIPTION + "Setting this object to cold start ups" + ::= { upsConfig 12 } + + +upsCfgBypassNotAllowed OBJECT-TYPE + SYNTAX INTEGER { + disable(0), + enable(1), + notsupport(2) + + } + ACCESS read-write + STATUS current + DESCRIPTION + "Setting this object to enable/disable bypass mode" + ::= { upsConfig 13 } + + +upsCfgBatterylowprotect OBJECT-TYPE + SYNTAX INTEGER { + disable(0), + enable(1), + notsupport(2) + + } + ACCESS read-write + STATUS current + DESCRIPTION + "Setting this object to enable/disable battery low protect" + ::= { upsConfig 14 } + + + +upsCfgP1progoutletcontrol OBJECT-TYPE + SYNTAX INTEGER { + disable(0), + enable(1), + notsupport(2) + } + ACCESS read-write + STATUS current + DESCRIPTION + "Setting this object to enable/disable p1 programmable outlet control (battery mode)" + ::= { upsConfig 15 } + + + +upsCfgP2progoutletcontrol OBJECT-TYPE + SYNTAX INTEGER { + disable(0), + enable(1), + notsupport(2) + } + ACCESS read-write + STATUS current + DESCRIPTION + "Setting this object to enable/disable p2 programmable outlet control (battery mode)" + ::= { upsConfig 16 } + + +upsCfgInverterShortClear OBJECT-TYPE + SYNTAX INTEGER { + disable(0), + enable(1), + notsupport(2) + } + ACCESS read-write + STATUS current + DESCRIPTION + "Setting this object to enable/disable Inverter short clear function" + ::= { upsConfig 17 } + + + + +upsCfgSitefaildetection OBJECT-TYPE + SYNTAX INTEGER { + disable(0), + enable(1), + notsupport(2) + } + ACCESS read-write + STATUS current + DESCRIPTION + "Setting this object to enable/disable site fail detection" + ::= { upsConfig 18 } + + + +upsCfgBatNumInParallel OBJECT-TYPE + SYNTAX INTEGER (1..99) + ACCESS read-write + STATUS current + DESCRIPTION + "Battery numbers in parallel (battery numbers setting)" + ::= { upsConfig 19 } + + +upsCfgBatNumInSeries OBJECT-TYPE + SYNTAX INTEGER (1..20) + ACCESS read-write + STATUS current + DESCRIPTION + "Battery numbers in series (battery numbers setting)" + ::= { upsConfig 20 } + + + +upsCfgBypassmaxvoltage OBJECT-TYPE + SYNTAX INTEGER (1760..2760) + UNITS "0.1 Volts" + ACCESS read-write + STATUS current + DESCRIPTION + "Bypass mode max voltage" + + ::= { upsConfig 21 } + + +upsCfgBypassminvoltage OBJECT-TYPE + SYNTAX INTEGER (1760..2640) + UNITS "0.1 Volts" + ACCESS read-write + STATUS current + DESCRIPTION + "Bypass mode min voltage" + ::= { upsConfig 22 } + + +upsCfgBypassmaxfrequency OBJECT-TYPE + SYNTAX INTEGER (510..700) -- ( 510..600 ,610..700) + UNITS "0.1 Hertz" + ACCESS read-write + STATUS current + DESCRIPTION + "Bypass mode max frequency ,for 50 HZ (510..600) for 60HZ (610..700)" + ::= { upsConfig 23 } + + + +upsCfgBypassminfrequency OBJECT-TYPE + SYNTAX INTEGER (400..590) --(400..490,500..590) + UNITS "0.1 Hertz" + ACCESS read-write + STATUS current + DESCRIPTION + "Bypass mode min frequency, for 50HZ (400..490) for 60Hz (500..590)" + ::= { upsConfig 24 } + + + +upsCfgECOmaxvoltage OBJECT-TYPE + SYNTAX INTEGER (10..3000) + UNITS "0.1 Volts" + ACCESS read-write + STATUS current + DESCRIPTION + "ECO mode max voltage" + + ::= { upsConfig 25 } + +upsCfgECOminvoltage OBJECT-TYPE + SYNTAX INTEGER (10..3000) + UNITS "0.1 Volts" + ACCESS read-write + STATUS current + DESCRIPTION + "ECO mode min voltage" + ::= { upsConfig 26 } + + +upsCfgFreeRunMaxFrequency OBJECT-TYPE + SYNTAX INTEGER (400..700) + UNITS "0.1 Hertz " + ACCESS read-write + STATUS current + DESCRIPTION + "Free run mode max frequency" + ::= { upsConfig 27 } + + + +upsCfgFreeRunMinFrequency OBJECT-TYPE + SYNTAX INTEGER (400..700) + UNITS "0.1 Hertz " + ACCESS read-write + STATUS current + DESCRIPTION + "Free run mode min frequency" + ::= { upsConfig 28 } + + + + +upsCfgEPOStatus OBJECT-TYPE + SYNTAX INTEGER { + disable(0), + enable(1) + } + ACCESS read-only + STATUS current + DESCRIPTION + "Get EPO status,configured by mamual" + ::= { upsConfig 29 } + + + +upsCfgQSK1Status OBJECT-TYPE + SYNTAX INTEGER { + disable(0), + enable(1) + } + ACCESS read-only + STATUS current + DESCRIPTION + "Get QSK 1 status" + ::= { upsConfig 30 } + +upsCfgQSK2Status OBJECT-TYPE + SYNTAX INTEGER { + disable(0), + enable(1) + } + ACCESS read-only + STATUS current + DESCRIPTION + "Get QSK 2 status" + ::= { upsConfig 31 } + +upsCfgQSKT1Delaytime OBJECT-TYPE + SYNTAX INTEGER (0..999) + UNITS "minutes " + ACCESS read-only + STATUS current + DESCRIPTION + "Get QSKT 1 time delay" + ::= { upsConfig 32 } + +upsCfgQSKT2Delaytime OBJECT-TYPE + SYNTAX INTEGER (0..999) + UNITS "minutes " + ACCESS read-only + STATUS current + DESCRIPTION + "Get QSKT 2 time delay" + ::= { upsConfig 33 } + +upsCfgConstantPhaseAngle OBJECT-TYPE + SYNTAX INTEGER { + disable(0), + enable(1) + } + ACCESS read-write + STATUS current + DESCRIPTION + "setting this object to Enable/disable Constant Phase Angle function" + ::= { upsConfig 34 } + +---PE/PD q + +upsCfgInPhaseAngle OBJECT-TYPE + SYNTAX INTEGER { + Angle000(0), + Angle120(120), + Angle180(180), + Angle240(240) + } + ACCESS read-only + STATUS current + DESCRIPTION + "Get input phase angle" + ::= { upsConfig 35 } + +---QPD + +upsCfgOutPhaseAngle OBJECT-TYPE + SYNTAX INTEGER { + Angle000(0), + Angle120(120), + Angle180(180), + Angle240(240) + } + ACCESS read-write + STATUS current + DESCRIPTION + "Set output phase angle" + ::= { upsConfig 36 } + +---QPD PPD<NNN> + +upsCfgLimiRunOnBatMode OBJECT-TYPE + SYNTAX INTEGER { + disable(0), + enable(1), + notsupport(2) + } + ACCESS read-write + STATUS current + DESCRIPTION + "Enable/disable limited runtime on battery mode" + ::= { upsConfig 37 } + + +upsCfgChargingCurrent OBJECT-TYPE + SYNTAX INTEGER + UNITS "0.1 Amp DC" + ACCESS read-only + STATUS current + DESCRIPTION + "Set charging current to battery ." + ::= { upsConfig 38 } + +upsCfgBatSeftCheckVolt OBJECT-TYPE + SYNTAX INTEGER (2400..2800) + UNITS "0.1 Volts" + ACCESS read-write + STATUS current + DESCRIPTION + "BatTest until battery voltage lower than <nnn>" + ::= { upsConfig 39 } + +upsCfgOverChargVolt OBJECT-TYPE + SYNTAX INTEGER (130..143) + UNITS "0.1 Volts" + ACCESS read-write + STATUS current + DESCRIPTION + "set over charging voltage to per battery" + ::= { upsConfig 40 } + +upsCfgBattUnderVolt OBJECT-TYPE + SYNTAX INTEGER (2000..2400) + UNITS "0.1 Volts" + ACCESS read-write + STATUS current + DESCRIPTION + "set battery under voltage of setting value.value is a number ranging from 200V to 240V" + ::= { upsConfig 41 } + +upsCfgBattLowVolt OBJECT-TYPE + SYNTAX INTEGER + UNITS "0.1 Volts" + ACCESS read-write + STATUS current + DESCRIPTION + "set battery low voltage of setting value.it is 10 to 40V high than battery under voltage. + it is 10 to 40V high than battery under voltage.default 20. + it means that the battery low point is battery under add 20. + for example, if the battery under voltage is 210V, the battry low point voltage is 230V. + " + ::= { upsConfig 42 } + +upsCfgIn1VoltHLoss OBJECT-TYPE + SYNTAX INTEGER + UNITS "0.1 Volts" + ACCESS read-write + STATUS current + DESCRIPTION + "set input1 voltage high loss point." + ::= { upsConfig 43 } + +upsCfgIn1VoltLLoss OBJECT-TYPE + SYNTAX INTEGER + UNITS "0.1 Volts" + ACCESS read-write + STATUS current + DESCRIPTION + "set input1 voltage low loss point." + ::= { upsConfig 44 } + +upsCfgIn2VoltHLoss OBJECT-TYPE + SYNTAX INTEGER + UNITS "0.1 Volts" + ACCESS read-write + STATUS current + DESCRIPTION + "set input2 voltage high loss point." + ::= { upsConfig 45 } + +upsCfgIn2VoltLLoss OBJECT-TYPE + SYNTAX INTEGER + UNITS "0.1 Volts" + ACCESS read-write + STATUS current + DESCRIPTION + "set input2 voltage low loss point." + ::= { upsConfig 46 } + +upsCfgBatteryTurnOn OBJECT-TYPE + SYNTAX INTEGER { + disable(0), + enable(1), + notsupport(2) + } + ACCESS read-write + STATUS current + DESCRIPTION + "Enable/disable battery turn on." + ::= { upsConfig 47 } + +-- =========================================================================== +-- upsTraps +-- prefix = upsTraps +-- Traps group +-- =========================================================================== + + -- This section defines the well-known notifications sent by + -- UPS agents. + + -- this traps use one share trap-node for send traps ,the trap-node vlaue between 1 and 127. + -- the share trap-node name is trapleafnodev1v2; + +-- if failure or warning occur ,traps send immediately , if question not resolved,agent will resend every 4 seconds. +-- info only send once + +trapleafnodev103 OBJECT-TYPE + SYNTAX DisplayString (SIZE (16..16)) + ACCESS not-accessible + STATUS current + DESCRIPTION + "The share trap-node for send all traps,snmpcard V1-03 and later use this trap-node + char trap[16]; + trap[0]: trap[0]=1,fault trap ; trap[0]=0,warn trap" + ::= { upsTraps 998 } + +trapleafnodev1v2 OBJECT-TYPE + SYNTAX INTEGER (0..255) + ACCESS not-accessible + STATUS current + DESCRIPTION + "The share trap-node for send all traps" + ::= { upsTraps 999 } + + +cmpACFailure TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "AC failure" + ::= 1 + +cmpFanFailure TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Fan failure" + ::= 2 + +cmpUPSFailure TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "UPS failure" + ::= 3 + +cmpChargerFailure TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Charger failure" + ::= 4 + +cmpOverloadFailure TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Overload failure" + ::= 5 + +cmpOvertempFailure TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Over temperature fault." + ::= 6 + +cmpInvertershortcircuited TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Inverter short-circuited" + ::= 7 + +cmpbatteryfusebeingoc TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Battery fuse being open-dcircuited failure" + ::= 8 + + + +cmpLowbattery TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "The UPS has returned from a low battery + condition." + ::= 9 + +cmpSysgotoshutdown TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "System is going to shutdown" + ::= 10 + + +cmpSitefault TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Site fault" + ::= 11 + + +cmpPhasesequenceincorrect TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Phase sequence incorrect" + ::= 12 + +cmpPhasesequenceincorrectbypass TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Phase sequence incorrect in bypass" + ::= 13 + +cmpFanalarm TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Fan alarm." + ::= 14 + + +cmpEPOenabled TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "EPO enabled" + ::= 15 + +cmpUnabletotrunonUPS TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Unalbe to turn on UPS" + ::= 16 + +cmpOvertemperaturealarm TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Over temperature alarm" + ::= 17 + +cmpInputfrequnstablebypass TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Input frequency unstable in bypass" + ::= 18 + + +cmpChargeralarm TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Charger alarm" + ::= 19 + + +cmpL1inputfusenotwork TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "L1 input fuse not working" + ::= 20 + +cmpNeutralnotConnected TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Neutral not connected" + ::= 21 + +cmpL2inputfusenotwork TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "L2 input fuse not working" + ::= 22 + +cmpL3inputfusenotwork TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "L3 input fuse not working" + ::= 23 + + +cmpPositivePFCabnormalL1 TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Positive PFC abnormal in L1" + ::= 24 + + +cmpNegativePFCabnormalL1 TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Negative PFC abnormal in L1" + ::= 25 + + +cmpPositivePFCabnormalL2 TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Positive PFC abnormal in L2" + ::= 26 + +cmpNegativePFCabnormalL2 TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Negative PFC abnormal in L2" + ::= 27 + +cmpPositivePFCabnormalL3 TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Positive PFC abnormal in L3" + ::= 28 + +cmpNegativePFCabnormalL3 TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Negative PFC abnormal in L3" + ::= 29 + + +cmpBusvoltagenotwds TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Bus voltage not within default setting" + ::= 30 + + +cmpBusvoltageovermaxvalue TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Bus voltage over maxinum value" + ::= 31 + +cmpBusvoltagebelowminvalue TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Bus voltage below mininum value" + ::= 32 + +cmpBusvoltagediffoutofrange TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Bus voltage differences out fo acceptable range" + ::= 33 + +cmpBusvoltageofsloperatetoofast TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Bus voltage of slope rate drops too fast" + ::= 34 + +cmpOvercurrentinPFCII TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "WARNING:Over current in PFC input inductor." + ::= 35 + +cmpInvertervoloutofrange TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Inverter voltage not within default setting." + ::= 36 + +cmpInvertervolovermaxvalue TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Inverter voltage over maximum value." + ::= 37 + +cmpInvertervolbelowminvalue TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Inverter voltage below minimum value." + ::= 38 + + +cmpBatteryoppositelyconnected TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Battery oppositely connected." + ::= 39 + +cmpL2phaseshortcicuited TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "L2Phase inverter short-cicuited." + ::= 40 + +cmpL3phaseshortcicuited TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "L3Phase inverter short-cicuited." + ::= 41 + +cmpL1L2invertershortcicuited TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "L1L2Inverter short-cicuited." + ::= 42 + +cmpL2L3invertershortcicuited TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "L2L3Inverter short-cicuited." + ::= 43 + +cmpL3L1invertershortcicuited TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "L3L1Inverter short-cicuited." + ::= 44 + + +cmpL1negativepoweroutofrange TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "L1 inverter negative powere out of acceptable range." + ::= 45 + +cmpL2negativepoweroutofrange TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "L2 inverter negative powere out of acceptable range." + ::= 46 + +cmpL3negativepoweroutofrange TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "L3 inverter negative powere out of acceptable range." + ::= 47 + +cmpBatterySCRshortcircuited TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Battery SCR short-circuited." + ::= 48 + +cmpLineSCRshortcircuited TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Line SCR short-circuited." + ::= 49 + +cmpInverterrelayopenfault TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Inverter relay open fault." + ::= 50 + +cmpInverterrelayshortcircuited TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Inverter relay short-circuited." + ::= 51 + +cmpInoutwiresoppositelyconnected TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Input and output wires oppositely connected." + ::= 52 + +cmpabnormalcanbuscommunication TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Abnormal in CAN-bus communication." + ::= 53 + +cmpcommfailurebcupsboard TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Communication failure between cpus in control board.Or DSP and MCU communication error" + ::= 54 + +cmpabnormalsyncsignalcircuit TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Abnomal in synchronous signal circuit." + ::= 55 + +cmpabnormalsyncpulsesignalcircuit TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Abnomal in synchronous pulse signal circuit." + ::= 56 + + +cmpcurrent3punbalancedetected TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Warning for a three-phase input current unbalance detected." + ::= 57 + +cmpbatteryselftestfailure TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Battery self-test failure." + ::= 58 + +cmpintercurrentunbalance TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Inverter inter-current unbalance." + ::= 59 + +cmpbatterydisconnected TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Battery disconnected." + ::= 60 + +cmpabnormalhostsignalcircuit TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Abnormal in host signal circuit." + ::= 61 + +cmpbatteryovercharged TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Bettery overcharged." + ::= 62 + +cmpbatteryvoltoohigh TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Bettery voltage is too high." + ::= 63 + +cmpbatteryvoltoolow TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Bettery voltage is too low." + ::= 64 + +cmpfemaleconnectornotconnwell TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Female connector of parallel cable not connected well." + ::= 65 + +cmpmaleconnectornotconnwell TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Male connector of parallel cable not connected well." + ::= 66 + + +cmplockingbypassA3COW30M TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Locking inbypass mode after 3 consecutive overloads within 30 minutes" + + ::= 67 + + +cmpparallelcabledisconnected TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Parallel cable disconnected" + + ::= 68 + +cmpsyncpulsecircuitfault TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Synchronous pulse signal circuit fault" + + ::= 69 + + +cmpsyncsignalcircuitfalt TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Synchronous signal circuit fault" + + ::= 70 + +cmphostsignalcircuitfault TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Host signal circuit fault" + + ::= 71 + +cmpcanbuscommunicationfault TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Can-bus communication fault" + + ::= 72 + +cmplowlosspointforvolinACmode TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Low loss point for voltage in ac mode not consistent in parallel systems" + + ::= 73 + +cmphighlosspointforvolinACmode TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "High loss point for voltage in ac mode not consistent in parallel systems" + + ::= 74 + +cmplowlosspointforfreqinACmode TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Low loss point for frequency in ac mode not consistent in parallel systems" + + ::= 75 + +cmphighlosspointforfreqinACmode TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "High loss point for frequency in ac mode not consistent in parallel systems" + + ::= 76 + +cmplowlosspointforvolinbypassmode TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Low loss point for voltage in bypass mode not consistent in parallel systems" + + ::= 77 + + +cmphighlosspointforvolinbypassmode TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "High loss point for voltage in bypass mode not consistent in parallel systems" + + ::= 78 + + +cmplowlosspointforfreqinbypassmode TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Low loss point for frequency in bypass mode not consistent in parallel systems" + + ::= 79 + +cmphighlosspointforfreqinbypassmode TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "High loss point for frequency in bypass mode not consistent in parallel systems" + + ::= 80 + +cmploadunbalanced TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Load unbalanced" + + ::= 81 + + +cmpoverloadalarm TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Overload alarm" + + ::= 82 + + +cmpparallelnotconnectedwell TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Parallel cable not connected well" + + ::= 83 + +cmpcommunicationlost TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Communication lost" + ::= 84 + + +cmpbatteryconnnotsonsistent TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Battery connection not consistent in parallel systems" + ::= 85 + + +cmpconverternotconsisstent TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Converter setting not consistent in parallel systems" + ::= 86 + +cmpbypassnotallownotconsistent TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Bypass not allowed setting not consistent in parallel systems" + ::= 87 + + +cmpACconnnotconsistent TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "AC connection not consistent in parallel systems" + ::= 88 + +cmpinput3pcurrentunbalance TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Warning for three-phase ac input current unbalance" + ::= 89 + +cmpbypassconnnotconsistent TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Bypass connection not consistent in parallel systems" + ::= 90 + +cmpbatteryprotectionnotconsistent TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Battery protection setting not consistent in parallel systems" + ::= 91 + +cmpbatterydetectionnotconsistent TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Battery detection setting not consistent in parallel systems" + ::= 92 + + + +cmpupsmodeltypesnotconsistent TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "UPS model types not consistent in parallel systems" + ::= 93 + +cmpbypassnotconsistent TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Bypass setting not consistent in parallel systems" + ::= 94 + + +cmpcapacitynotconsistent TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Capacity of upss not consistent in parallel systems" + ::= 95 + +cmpautorestartnotconsistent TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Auto restart setting not consistent in parallel systems" + ::= 96 + + +cmpBatteryReplace TRAP-TYPE ENTERPRISE upsTraps + DESCRIPTION + "Battery need to be replace" + ::= 97 + + +cmpACNormal TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "AC normal" + ::= 100 + +cmpOutputBadAlarm TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Output bad alarm" + ::= 103 + + +cmpBypassBadAlarm TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Bypass bad alarm" + ::= 104 + + +cmpOutputOffAlarm TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Output off alarm" + ::= 105 + + +cmpUPSShutAlarm TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "UPS shutdown alarm" + ::= 106 + +cmpSystemOffAlarm TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "System off alarm" + ::= 107 + +cmpFuseFailureAlarm TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Fuse failure alarm" + ::= 108 + +cmpGenFailureAlarm TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "General failure alarm" + ::= 109 + +cmpAwaitPowerAlarm TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Awaiting power alarm" + ::= 110 + +cmpShutPendingAlarm TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Shutdown pending alarm" + ::= 111 + +cmpBatDepleted TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Battery depleted" + ::= 112 + + +cmpUnknowStatus TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Battery unknow status" + ::= 113 + +cmpOutputOn TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Output on" + ::= 114 + +cmpTurntobypass TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Ups turn to bypass mode" + ::= 115 + +cmpTurntobattery TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Ups turn to battery mode" + ::= 116 + +cmpOutBooster TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Turn to booster" + ::= 117 + + +cmpOutReducer TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Turn to reducer" + ::= 118 + +cmpOutBattest TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Turn to battery test mode" + ::= 119 + + +cmpOtherSource TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Other source" + ::= 120 + +cmpBatfailure TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Battery failure" + ::= 121 + + +cmpBatTestDonePassed TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Battery test passed" + ::= 122 + +cmpBatTestDoneWarning TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Battery test done warning " + ::= 123 + + +cmpBatTestDoneAborted TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Battery test done Aborted" + ::= 124 + +cmpBatteryNormal TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Battery normal" + ::= 125 + +cmpBatteryDischarging TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Battery Discharging " + ::= 126 + +cmpP1cutoffprealarm TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "P1 cut off pre-alarm " + ::= 127 + +cmpInputPhaseError TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Warning for input phase error for LV 6-10K UPS" + ::= 128 +cmpMaintainSwitchOpenalarm TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "Warning for maintain switch open" + ::= 129 + +cmpEMDChAbnormal1 TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "EMD Channels 1 Abnormal" + ::= 130 +cmpEMDChAbnormal2 TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "EMD Channels 2 Abnormal" + ::= 131 +cmpEMDChAbnormal3 TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "EMD Channels 3 Abnormal" + ::= 132 +cmpEMDChAbnormal4 TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "EMD Channels 4 Abnormal" + ::= 133 +cmpEMDChAbnormal5 TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "EMD Channels 5 Abnormal: smoke alarm" + ::= 134 +cmpEMDChAbnormal6 TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "EMD Channels 6 Abnormal" + ::= 135 +cmpEMDChAbnormal7 TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "EMD Channels 7 Abnormal" + ::= 136 +cmpEMDChAbnormal8 TRAP-TYPE + ENTERPRISE upsTraps + DESCRIPTION + "EMD Channels 8 Abnormal" + ::= 137 +--=============================================================================== +--extend +--=============================================================================== + +extendWorkTemperature OBJECT-TYPE + SYNTAX INTEGER (-2200..2200) + UNITS "degrees 0.1 Centigrade" + ACCESS read-only + STATUS current + DESCRIPTION + "The temperature of work environment" + ::= { extend 1 } + +extendWorkhumidity OBJECT-TYPE + SYNTAX INTEGER (0..100) + UNITS "percent" + ACCESS read-only + STATUS current + DESCRIPTION + "The humidity of work environment" + ::= { extend 2 } + + +extendSmokeScope OBJECT-TYPE + SYNTAX INTEGER (0..1000000) + UNITS "%/FOOT" + ACCESS read-only + STATUS current + DESCRIPTION + "The smokeScope of work environment" + ::= { extend 3 } + + +extendEMDAlarm1 OBJECT-TYPE + SYNTAX INTEGER { + on(1), + off(0) + } + ACCESS read-only + STATUS current + DESCRIPTION + "Environment detector alarm 1" + ::= { extend 4 } + +extendEMDAlarm2 OBJECT-TYPE + SYNTAX INTEGER { + on(1), + off(0) + } + ACCESS read-only + STATUS current + DESCRIPTION + "Environment detector alarm 2" + ::= { extend 5 } + + +extendEMDAlarm3 OBJECT-TYPE + SYNTAX INTEGER { + on(1), + off(0) + } + ACCESS read-only + STATUS current + DESCRIPTION + "Environment detector alarm 3" + ::= { extend 6 } + +extendEMDAlarm4 OBJECT-TYPE + SYNTAX INTEGER { + on(1), + off(0) + } + ACCESS read-only + STATUS current + DESCRIPTION + "Environment detector alarm 4" + ::= { extend 7 } + +END |