summaryrefslogtreecommitdiff
path: root/MIBS/quanta/sflow.my
diff options
context:
space:
mode:
authorDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
committerDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
commit98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch)
tree9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/quanta/sflow.my
downloadmibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.tar.gz
mibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.zip
Initial commitHEADmain
Diffstat (limited to 'MIBS/quanta/sflow.my')
-rw-r--r--MIBS/quanta/sflow.my535
1 files changed, 535 insertions, 0 deletions
diff --git a/MIBS/quanta/sflow.my b/MIBS/quanta/sflow.my
new file mode 100644
index 0000000..cc03d77
--- /dev/null
+++ b/MIBS/quanta/sflow.my
@@ -0,0 +1,535 @@
+SFLOW-MIB DEFINITIONS ::= BEGIN
+
+IMPORTS
+
+ MODULE-IDENTITY, OBJECT-TYPE, Integer32, enterprises
+ FROM SNMPv2-SMI
+ TEXTUAL-CONVENTION
+ FROM SNMPv2-TC
+ SnmpAdminString
+ FROM SNMP-FRAMEWORK-MIB
+ OwnerString
+ FROM RMON-MIB
+ InetAddressType, InetAddress
+ FROM INET-ADDRESS-MIB
+ MODULE-COMPLIANCE, OBJECT-GROUP
+ FROM SNMPv2-CONF;
+
+ sFlowMIB MODULE-IDENTITY
+ LAST-UPDATED "200309240000Z" -- September 24, 2003
+ ORGANIZATION "Netgear Inc"
+ CONTACT-INFO ""
+
+ DESCRIPTION
+ "The MIB module for managing the generation and transportation
+ of sFlow data records."
+
+ --
+ -- Revision History
+ --
+
+ REVISION "200310180000Z" -- November 18, 2003
+ DESCRIPTION
+ "Version 1.3 (draft 5)
+
+ Allow set to SFlowReceiver if it doesn't change
+ value."
+
+ REVISION "200309240000Z" -- September 24, 2003
+ DESCRIPTION
+ "Version 1.3 (draft 4)
+
+ Default value of sFlowRcvrAddress should be '00000000' h.
+ Default value of sFlowCpReceiver should be 0."
+
+ REVISION "200304080000Z" -- April 8, 2003
+ DESCRIPTION
+ "Version 1.3 (draft 3)
+
+ Clarify semantics of counter polling interval,
+ sFlowCpInterval."
+
+ REVISION "200209170000Z" -- September 17, 2002
+ DESCRIPTION
+ "Version 1.3 (draft 2)
+
+ Adds support for multiple sFlow samplers per sFlowDataSource.
+ Moved to sflow.org enterprise number.
+ Splits flow sampling, counter polling and receiver
+ specification into separate tables."
+
+ REVISION "200107310000Z" -- July 31, 2001
+ DESCRIPTION
+ "Version 1.2
+
+ Brings MIB into SMI v2 compliance."
+
+ REVISION "200105010000Z" -- May 1, 2001
+ DESCRIPTION
+ "Version 1.1
+
+ Adds sfDatagramVersion."
+
+ ::= { enterprises sflow(14706) 1 }
+
+ sFlowAgent OBJECT IDENTIFIER ::= { sFlowMIB 1 }
+
+ SFlowDataSource ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "Identifies a source of sFlow data.
+
+ The following data source types are currently defined:
+
+ - ifIndex.<I>
+ SFlowDataSources of this traditional form are called
+ 'port-based'. Ideally the sampling entity will perform
+
+ - smonVlanDataSource.<V>
+ An SFlowDataSource of this form refers to a 'Packet-based VLAN'
+ and is called a 'VLAN-based' dataSource. <V> is the VLAN
+ ID as defined by the IEEE 802.1Q standard. The
+ value is between 1 and 4094 inclusive, and it represents
+ an 802.1Q VLAN-ID with global scope within a given
+ bridged domain.
+
+ Note: Since each SFlowDataSource operates independently a
+ packet that crosses multiple DataSources may generate
+ multiple flow records."
+ SYNTAX OBJECT IDENTIFIER
+
+ SFlowInstance ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "If more than one sFlow sampler is available for this
+ SFlowDataSource then individual samplers are distinguished
+ using the SFlowInstance variable. The value of
+ SFlowInstance ranges from 1..n where n is the number of
+ samplers associated with this SFlowDataSource.
+
+ Note: Each sFlow sampler instance must operate
+ independently of all other instances. Setting
+ an attribute of one sampler must not alter the
+ the behavior and settings of other sampler
+ instances."
+ SYNTAX Integer32 (1..65535)
+
+ SFlowReceiver ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "Identify the sFlow receiver associated with this resource.
+
+ A value of zero indicates that this resource is available.
+ If non-zero the value must correspond to a valid, active
+ sFlowRcvrIndex.
+
+ If the value is currently zero it may be set to any
+ active entry in the sFlowRcvrTable. If the value is
+ not zero then a set to anything other than zero or
+ its current value will result in an SNMP error (bad value)."
+ SYNTAX Integer32
+
+ sFlowVersion OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Uniquely identifies the version and implementation of this MIB.
+ The version string must have the following structure:
+ <MIB Version>;<Organization>;<Software Revision>
+ where:
+ <MIB Version> must be '1.3', the version of this MIB.
+ <Organization> the name of the organization responsible
+ for the agent implementation.
+ <Revision> the specific software build of this agent.
+
+
+ The MIB Version will change with each revision of the SFLOW
+ MIB.
+
+ Management entities must check the MIB Version and not attempt
+ to manage agents with MIB Versions greater than that for which
+ they were designed.
+
+ Note: The sFlow Datagram Format has an independent version
+ number which may change independently from <MIB Version>.
+ <MIB Version> applies to the structure and semantics of
+ the SFLOW MIB only."
+ DEFVAL { "1.3;;" }
+ ::= { sFlowAgent 1 }
+
+ sFlowAgentAddressType OBJECT-TYPE
+ SYNTAX InetAddressType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The address type of the address associated with this agent.
+ Only ipv4 and ipv6 types are supported."
+ ::= { sFlowAgent 2 }
+
+ sFlowAgentAddress OBJECT-TYPE
+ SYNTAX InetAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The IP address associated with this agent. In the case of a
+ multi-homed agent, this should be the loopback address of the
+ agent. The sFlowAgent address must provide SNMP connectivity
+ to the agent. The address should be an invariant that does not
+ change as interfaces are reconfigured, enabled, disabled,
+ added or removed. A manager should be able to use the
+ sFlowAgentAddress as a unique key that will identify this
+ agent over extended periods of time so that a history can
+ be maintained."
+ ::= { sFlowAgent 3 }
+
+ --
+ -- Receiver Table
+ --
+
+ sFlowRcvrTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SFlowRcvrEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of the receivers of sFlow information."
+ ::= { sFlowAgent 4 }
+
+ sFlowRcvrEntry OBJECT-TYPE
+ SYNTAX SFlowRcvrEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Attributes of an sFlow Receiver."
+ INDEX { sFlowRcvrIndex }
+ ::= { sFlowRcvrTable 1 }
+
+ SFlowRcvrEntry ::= SEQUENCE {
+ sFlowRcvrIndex Integer32,
+ sFlowRcvrOwner OwnerString,
+ sFlowRcvrTimeout Integer32,
+ sFlowRcvrMaximumDatagramSize Integer32,
+ sFlowRcvrAddressType InetAddressType,
+ sFlowRcvrAddress InetAddress,
+ sFlowRcvrPort Integer32,
+ sFlowRcvrDatagramVersion Integer32
+ }
+
+ sFlowRcvrIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Index into sFlowReceiverTable."
+ ::= { sFlowRcvrEntry 1 }
+
+ sFlowRcvrOwner OBJECT-TYPE
+ SYNTAX OwnerString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The entity making use of this sFlowRcvrTable entry. The empty
+ string indicates that the entry is currently unclaimed.
+ An entity wishing to claim an sFlowRcvrTable entry must ensure
+ that the entry is unclaimed before trying to claim it.
+ The entry is claimed by setting the owner string. The entry
+ must be claimed before any changes can be made to other sampler
+ objects.
+
+ In order to avoid a race condition, the entity taking control
+ of the sampler must set both the owner and a value for
+ sFlowRcvrTimeout in the same SNMP set request.
+
+ When a management entity is finished using the sampler,
+ it should set the value of sFlowRcvrOwner back to unclaimed.
+ The agent must restore all other entities this row to their
+ default values when the owner is set to unclaimed. It must
+ also free all other resources associated with this
+ sFlowRcvrTable entry.
+
+ This mechanism provides no enforcement and relies on the
+ cooperation of management entities in order to ensure that
+ competition for a receiver entry is fairly resolved."
+ DEFVAL { "" }
+ ::= { sFlowRcvrEntry 2 }
+
+ sFlowRcvrTimeout OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The time (in seconds) remaining before the sampler is released
+ and stops sampling. When set, the owner establishes control
+ for the specified period. When read, the remaining time in the
+ interval is returned.
+
+ A management entity wanting to maintain control of the sampler
+ is responsible for setting a new value before the old one
+ expires.
+
+ When the interval expires, the agent is responsible for
+ restoring all other entities in this row to their default
+ values. It must also free all other resources associated with
+ this sFlowRcvrTable entry."
+ DEFVAL { 0 }
+ ::= { sFlowRcvrEntry 3 }
+
+ sFlowRcvrMaximumDatagramSize OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The maximum number of data bytes that can be sent in a single
+ sample datagram. The manager should set this value to avoid
+ fragmentation of the sFlow datagrams."
+ DEFVAL { 1400 }
+ ::= { sFlowRcvrEntry 4 }
+
+ sFlowRcvrAddressType OBJECT-TYPE
+ SYNTAX InetAddressType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The type of sFlowRcvrCollectorAddress."
+ DEFVAL { ipv4 }
+ ::= { sFlowRcvrEntry 5 }
+
+ sFlowRcvrAddress OBJECT-TYPE
+ SYNTAX InetAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The IP address of the sFlow collector.
+ If set to 0.0.0.0 not sFlow datagrams will be sent."
+ DEFVAL { '00000000'h } -- 0.0.0.0
+ ::= { sFlowRcvrEntry 6 }
+
+ sFlowRcvrPort OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The destination port for sFlow datagrams."
+ DEFVAL { 6343 }
+ ::= { sFlowRcvrEntry 7 }
+
+ sFlowRcvrDatagramVersion OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The version of sFlow datagrams that should be sent.
+
+ When set to a value not support by the agent, the agent should
+ adjust the value to the highest supported value less than the
+ requested value, or return an SNMP bad value error if no
+ such value exists."
+ DEFVAL { 5 }
+ ::= { sFlowRcvrEntry 8 }
+
+ --
+ -- Flow Sampling Table
+ --
+
+ sFlowFsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SFlowFsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of the flow samplers within a device."
+ ::= { sFlowAgent 5 }
+
+ sFlowFsEntry OBJECT-TYPE
+ SYNTAX SFlowFsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Attributes of a flow sampler."
+ INDEX { sFlowFsDataSource, sFlowFsInstance }
+ ::= { sFlowFsTable 1 }
+
+ SFlowFsEntry ::= SEQUENCE {
+ sFlowFsDataSource SFlowDataSource,
+ sFlowFsInstance SFlowInstance,
+ sFlowFsReceiver SFlowReceiver,
+ sFlowFsPacketSamplingRate Integer32,
+ sFlowFsMaximumHeaderSize Integer32
+ }
+
+ sFlowFsDataSource OBJECT-TYPE
+ SYNTAX SFlowDataSource
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "sFlowDataSource for this flow sampler."
+ ::= { sFlowFsEntry 1 }
+
+ sFlowFsInstance OBJECT-TYPE
+ SYNTAX SFlowInstance
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The sFlow instance for this flow sampler."
+ ::= { sFlowFsEntry 2 }
+
+ sFlowFsReceiver OBJECT-TYPE
+ SYNTAX SFlowReceiver
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The SFlowReceiver for this flow sampler."
+ DEFVAL { 0 }
+ ::= { sFlowFsEntry 3 }
+
+ sFlowFsPacketSamplingRate OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The statistical sampling rate for packet sampling from this
+ source.
+
+ Set to N to sample 1/Nth of the packets in the monitored flows.
+ An agent should choose its own algorithm to introduce variance
+ into the sampling so that exactly every Nth packet is not
+ counted. A sampling rate of 1 counts all packets. A sampling
+ rate of 0 disables sampling.
+
+ The agent is permitted to have minimum and maximum allowable
+ values for the sampling rate. A minimum rate lets the agent
+ designer set an upper bound on the overhead associated with
+ sampling, and a maximum rate may be the result of hardware
+ restrictions (such as counter size). In addition not all values
+ between the maximum and minimum may be realizable as the
+ sampling rate (again because of implementation considerations).
+
+ When the sampling rate is set the agent is free to adjust the
+ value so that it lies between the maximum and minimum values
+ and has the closest achievable value.
+
+ When read, the agent must return the actual sampling rate it
+ will be using (after the adjustments previously described). The
+ sampling algorithm must converge so that over time the number
+ of packets sampled approaches 1/Nth of the total number of
+ packets in the monitored flows."
+ DEFVAL { 0 }
+ ::= { sFlowFsEntry 4 }
+
+ sFlowFsMaximumHeaderSize OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The maximum number of bytes that should be copied from a
+ sampled packet. The agent may have an internal maximum and
+ minimum permissible sizes. If an attempt is made to set this
+ value outside the permissible range then the agent should
+ adjust the value to the closest permissible value."
+ DEFVAL { 128 }
+ ::= { sFlowFsEntry 5 }
+
+ --
+ -- Counter Polling Table
+ --
+
+
+ sFlowCpTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SFlowCpEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of the counter pollers within a device."
+ ::= { sFlowAgent 6 }
+
+ sFlowCpEntry OBJECT-TYPE
+ SYNTAX SFlowCpEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Attributes of a counter poller."
+ INDEX { sFlowCpDataSource, sFlowCpInstance }
+ ::= { sFlowCpTable 1 }
+
+ SFlowCpEntry ::= SEQUENCE {
+ sFlowCpDataSource SFlowDataSource,
+ sFlowCpInstance SFlowInstance,
+ sFlowCpReceiver SFlowReceiver,
+ sFlowCpInterval Integer32
+ }
+
+ sFlowCpDataSource OBJECT-TYPE
+ SYNTAX SFlowDataSource
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Identifies the source of the data for the counter poller."
+ ::= { sFlowCpEntry 1 }
+
+ sFlowCpInstance OBJECT-TYPE
+ SYNTAX SFlowInstance
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The sFlowInstance for this counter poller."
+ ::= { sFlowCpEntry 2 }
+
+ sFlowCpReceiver OBJECT-TYPE
+ SYNTAX SFlowReceiver
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The SFlowReciever associated with this counter poller."
+ DEFVAL { 0 }
+ ::= { sFlowCpEntry 3 }
+
+ sFlowCpInterval OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The maximum number of seconds between successive samples of the
+ counters associated with this data source. A sampling interval
+ of 0 disables counter sampling."
+ DEFVAL { 0 }
+ ::= { sFlowCpEntry 4 }
+
+
+ sFlowMIBConformance OBJECT IDENTIFIER ::= { sFlowMIB 2 }
+ sFlowMIBGroups OBJECT IDENTIFIER ::= { sFlowMIBConformance 1 }
+ sFlowMIBCompliances OBJECT IDENTIFIER ::= { sFlowMIBConformance 2 }
+
+ sFlowCompliance MODULE-COMPLIANCE
+ STATUS current
+ DESCRIPTION
+ "Compliance statements for the sFlow Agent."
+
+ MODULE -- this module
+ MANDATORY-GROUPS { sFlowAgentGroup }
+
+ OBJECT sFlowAgentAddressType
+ SYNTAX InetAddressType
+ DESCRIPTION
+ "Agents need only support ipv4."
+
+ OBJECT sFlowRcvrAddressType
+ SYNTAX InetAddressType
+ DESCRIPTION
+ "Agents need only support ipv4."
+
+ ::= { sFlowMIBCompliances 1 }
+
+ sFlowAgentGroup OBJECT-GROUP
+ OBJECTS { sFlowVersion, sFlowAgentAddressType, sFlowAgentAddress,
+ sFlowRcvrOwner, sFlowRcvrTimeout,
+ sFlowRcvrMaximumDatagramSize, sFlowRcvrAddressType,
+ sFlowRcvrAddress, sFlowRcvrPort,
+ sFlowRcvrDatagramVersion, sFlowFsReceiver,
+ sFlowFsPacketSamplingRate, sFlowFsMaximumHeaderSize,
+ sFlowCpReceiver, sFlowCpInterval }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects for managing the generation and
+ transportation of sFlow data records."
+ ::= { sFlowMIBGroups 1 }
+
+END