diff options
| author | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
|---|---|---|
| committer | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
| commit | 98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch) | |
| tree | 9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/raisecom/ROSMGMT-OPTICAL-TRANSCEIVER-MIB | |
| download | mibs-main.tar.gz mibs-main.zip | |
Diffstat (limited to 'MIBS/raisecom/ROSMGMT-OPTICAL-TRANSCEIVER-MIB')
| -rw-r--r-- | MIBS/raisecom/ROSMGMT-OPTICAL-TRANSCEIVER-MIB | 2251 |
1 files changed, 2251 insertions, 0 deletions
diff --git a/MIBS/raisecom/ROSMGMT-OPTICAL-TRANSCEIVER-MIB b/MIBS/raisecom/ROSMGMT-OPTICAL-TRANSCEIVER-MIB new file mode 100644 index 0000000..647251a --- /dev/null +++ b/MIBS/raisecom/ROSMGMT-OPTICAL-TRANSCEIVER-MIB @@ -0,0 +1,2251 @@ +--MibName=ROSMGMT-OPTICAL-TRANSCEIVER-MIB.mib
+-- *****************************************************************
+-- ROSMGMT-OPTICAL-TRANSCEIVER-MIB.mib
+--
+-- Copyright(c) 2003-2005 by RAISECOM TECH, Ltd.
+-- All rights reserved.
+-- *****************************************************************
+
+-- *****************************************************************
+-- Modi Report£ºFormat: <number>, <time>, <author>, <desc>
+-- 01, 20110623, yangzhognhong, change the value of the node raisecomOpticalTransceiverMediaType
+-- for SFP+ development
+--
+-- *****************************************************************
+
+
+ROSMGMT-OPTICAL-TRANSCEIVER-MIB DEFINITIONS ::= BEGIN
+
+IMPORTS
+ Integer32, Unsigned32,
+ MODULE-IDENTITY,
+ NOTIFICATION-TYPE,
+ OBJECT-TYPE,TimeTicks FROM SNMPv2-SMI
+ rosMgmt FROM RAISECOM-BASE-MIB
+ TEXTUAL-CONVENTION,
+ TruthValue FROM SNMPv2-TC
+-- OBJECT-GROUP FROM SNMPv2-CONF
+ ifIndex FROM IF-MIB;
+-- raisecomNotificationLocation FROM RAISECOM-COMMON-MANAGEMENT-MIB
+-- ClearVar FROM SWITCH-TC;
+
+rosMgmtOpticalTransceiver MODULE-IDENTITY
+ LAST-UPDATED "202004160000Z"
+ ORGANIZATION "Raisecom, Inc."
+ CONTACT-INFO
+ " Raise Systems
+
+ Postal: Beijing,
+ China
+
+ Tel: 86-010-82884499
+
+ E-mail: chenyu@raisecom.com"
+ DESCRIPTION
+ "This MIB module defines objects to monitor optical
+ characteristics on the optical interfaces in a network element. "
+ REVISION "202004160000Z"
+ DESCRIPTION
+ "The initial revision of this MIB."
+ ::={ rosMgmt 18 }
+
+rosMgmtOpticalTransceiverNotifications OBJECT IDENTIFIER ::= { rosMgmtOpticalTransceiver 0 }
+rosMgmtOpticalTransceiverObjects OBJECT IDENTIFIER ::= { rosMgmtOpticalTransceiver 1 }
+rosMgmtOpticalTransceiverConformance OBJECT IDENTIFIER ::= { rosMgmtOpticalTransceiver 2 }
+
+
+rosMgmtOpticalTransceiverAbsentTrap NOTIFICATION-TYPE
+ OBJECTS { rosMgmtOpticalTransceiverHwInfoAbsStatus,
+ rosMgmtOpticalTransceiverSpecificationCheckStatus }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when the optical module is removed from the device.
+
+ This notification may be suppressed under the following
+ conditions:
+ - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
+ "
+ ::={ rosMgmtOpticalTransceiverNotifications 1 }
+
+rosMgmtOpticalTransceiverPresentTrap NOTIFICATION-TYPE
+ OBJECTS { rosMgmtOpticalTransceiverHwInfoAbsStatus,
+ rosMgmtOpticalTransceiverSpecificationCheckStatus }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when the optical module is plugged into the device.
+
+ This notification may be suppressed under the following
+ conditions:
+ - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
+ "
+ ::={ rosMgmtOpticalTransceiverNotifications 2 }
+
+rosMgmtOpticalTransceiverNRAlarmTrap NOTIFICATION-TYPE
+ OBJECTS { rosMgmtOpticalTransceiverHwInfoNRStatus }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when the transmitted or received data of optical module is invalid.
+
+ This notification may be suppressed under the following
+ conditions:
+ - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
+ "
+ ::={ rosMgmtOpticalTransceiverNotifications 3 }
+
+rosMgmtOpticalTransceiverNRNormalTrap NOTIFICATION-TYPE
+ OBJECTS { rosMgmtOpticalTransceiverHwInfoNRStatus }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when the transmitted or received data of optical module is valid.
+
+ This notification may be suppressed under the following
+ conditions:
+ - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
+ "
+ ::={ rosMgmtOpticalTransceiverNotifications 4 }
+
+rosMgmtOpticalTransceiverRxLosAlarmTrap NOTIFICATION-TYPE
+ OBJECTS { rosMgmtOpticalTransceiverHwInfoRxLosStatus }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when the optical module receiving signal is lost.
+
+ This notification may be suppressed under the following
+ conditions:
+ - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
+ "
+ ::={ rosMgmtOpticalTransceiverNotifications 5 }
+
+rosMgmtOpticalTransceiverRxLosNormaTrap NOTIFICATION-TYPE
+ OBJECTS {rosMgmtOpticalTransceiverHwInfoRxLosStatus }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when the optical module receiving signal is back to normal.
+
+ This notification may be suppressed under the following
+ conditions:
+ - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
+ "
+ ::={ rosMgmtOpticalTransceiverNotifications 6 }
+
+--raisecomOpticalTransceiverCheckPwdFailureTrap NOTIFICATION-TYPE
+-- STATUS current
+-- DESCRIPTION
+-- "This notification is sent when the optical module password checking is failed.
+
+-- This notification may be suppressed under the following
+-- conditions:
+-- - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
+-- "
+-- ::={ rosMgmtOpticalTransceiverNotifications 7 }
+
+--raisecomOpticalTransceiverCheckPwdSucceedTrap NOTIFICATION-TYPE
+-- STATUS current
+-- DESCRIPTION
+-- "This notification is sent when the optical module password cheching is successful.
+
+-- This notification may be suppressed under the following
+-- conditions:
+-- - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
+-- "
+-- ::={ rosMgmtOpticalTransceiverNotifications 8 }
+
+rosMgmtOpticalTransceiverParamAlarmTrap NOTIFICATION-TYPE
+ OBJECTS { rosMgmtOpticalTransceiverParameterValue,
+ rosMgmtOpticalTransceiverParamAlarmStatus }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when the optical module parameter value increase to above
+ the high alarm threshold or dicrease to under the low alarm threshold.
+
+
+ This notification may be suppressed under the following
+ conditions:
+ - depending on the value of the rosMgmtOpticalNotifyEnable and rosMgmtOpticalPortNotifyEnable objects.
+ "
+ ::={ rosMgmtOpticalTransceiverNotifications 7 }
+
+rosMgmtOpticalTransceiverParamAlarmNormalTrap NOTIFICATION-TYPE
+ OBJECTS { rosMgmtOpticalTransceiverParameterValue,
+ rosMgmtOpticalTransceiverParamAlarmStatus }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when the optical module parameter value dicrease to
+ under the high alarm threshold or increase to above the low alarm threshold.
+
+ This notification may be suppressed under the following
+ conditions:
+ - depending on the value of the rosMgmtOpticalNotifyEnable and rosMgmtOpticalPortNotifyEnable objects.
+ "
+ ::={ rosMgmtOpticalTransceiverNotifications 8 }
+
+rosMgmtOpticalTransceiverParamWarningTrap NOTIFICATION-TYPE
+ OBJECTS { rosMgmtOpticalTransceiverParameterValue,
+ rosMgmtOpticalTransceiverParamAlarmStatus }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when the optical module parameter value increase to above
+ the high warning threshold or dicrease to under the low warning threshold.
+
+ This notification may be suppressed under the following
+ conditions:
+ - depending on the value of the rosMgmtOpticalNotifyEnable and rosMgmtOpticalPortNotifyEnable objects.
+ "
+ ::={ rosMgmtOpticalTransceiverNotifications 9 }
+
+rosMgmtOpticalTransceiverParamWarningNormalTrap NOTIFICATION-TYPE
+ OBJECTS { rosMgmtOpticalTransceiverParameterValue,
+ rosMgmtOpticalTransceiverParamAlarmStatus }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when the optical module parameter value dicrease to
+ under the high warning threshold or increase to above the low warning threshold.
+
+ This notification may be suppressed under the following
+ conditions:
+ - depending on the value of the rosMgmtOpticalNotifyEnable and rosMgmtOpticalPortNotifyEnable objects.
+ "
+ ::={ rosMgmtOpticalTransceiverNotifications 10 }
+
+rosMgmtOpticalTransceiverLaserBackLightAlarmTrap NOTIFICATION-TYPE
+ OBJECTS { rosMgmtOpticalTransceiverParameterValue,
+ rosMgmtOpticalTransceiverParamAlarmStatus }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when the optical module password cheching is successful.
+
+ This notification may be suppressed under the following
+ conditions:
+ - depending on the value of the rosMgmtOpticalNotifyEnable and rosMgmtOpticalPortNotifyEnable objects.
+ "
+ ::={ rosMgmtOpticalTransceiverNotifications 11 }
+
+rosMgmtOpticalTransceiverLaserBackLightAlarmNormalTrap NOTIFICATION-TYPE
+ OBJECTS { rosMgmtOpticalTransceiverParameterValue,
+ rosMgmtOpticalTransceiverParamAlarmStatus }
+
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when the optical module password cheching is successful.
+
+ This notification may be suppressed under the following
+ conditions:
+ - depending on the value of the rosMgmtOpticalNotifyEnable and rosMgmtOpticalPortNotifyEnable objects.
+ "
+ ::={ rosMgmtOpticalTransceiverNotifications 12 }
+
+rosMgmtOpticalTransceiverLaserLifeAlarmTrap NOTIFICATION-TYPE
+ OBJECTS { rosMgmtOpticalTransceiverParameterValue,
+ rosMgmtOpticalTransceiverParamAlarmStatus }
+
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when the optical module password cheching is successful.
+
+ This notification may be suppressed under the following
+ conditions:
+ - depending on the value of the rosMgmtOpticalNotifyEnable and rosMgmtOpticalPortNotifyEnable objects.
+ "
+ ::={ rosMgmtOpticalTransceiverNotifications 13 }
+
+rosMgmtOpticalTransceiverLaserLifeAlarmNormalTrap NOTIFICATION-TYPE
+ OBJECTS { rosMgmtOpticalTransceiverParameterValue,
+ rosMgmtOpticalTransceiverParamAlarmStatus }
+
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when the optical module password cheching is successful.
+
+ This notification may be suppressed under the following
+ conditions:
+ - depending on the value of the rosMgmtOpticalNotifyEnable and rosMgmtOpticalPortNotifyEnable objects.
+ "
+ ::={ rosMgmtOpticalTransceiverNotifications 14 }
+
+rosMgmtOpticalTransceiverParamLowAlarmTrap NOTIFICATION-TYPE
+ OBJECTS { rosMgmtOpticalTransceiverParameterValue,
+ rosMgmtOpticalTransceiverParamAlarmStatus }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when the optical module parameter value increase to above
+ the high alarm threshold or dicrease to under the low alarm threshold.
+
+
+ This notification may be suppressed under the following
+ conditions:
+ - depending on the value of the rosMgmtOpticalNotifyEnable and rosMgmtOpticalPortNotifyEnable objects.
+ "
+ ::={ rosMgmtOpticalTransceiverNotifications 15 }
+
+
+rosMgmtOpticalTransceiverParamLowAlarmNormalTrap NOTIFICATION-TYPE
+ OBJECTS { rosMgmtOpticalTransceiverParameterValue,
+ rosMgmtOpticalTransceiverParamAlarmStatus }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when the optical module parameter value increase to above
+ the high alarm threshold or dicrease to under the low alarm threshold.
+
+
+ This notification may be suppressed under the following
+ conditions:
+ - depending on the value of the rosMgmtOpticalNotifyEnable and rosMgmtOpticalPortNotifyEnable objects.
+ "
+ ::={ rosMgmtOpticalTransceiverNotifications 16 }
+
+rosMgmtOpticalTransceiverParamLowWarningTrap NOTIFICATION-TYPE
+ OBJECTS { rosMgmtOpticalTransceiverParameterValue,
+ rosMgmtOpticalTransceiverParamAlarmStatus }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when the optical module parameter value increase to above
+ the high alarm threshold or dicrease to under the low alarm threshold.
+
+
+ This notification may be suppressed under the following
+ conditions:
+ - depending on the value of the rosMgmtOpticalNotifyEnable and rosMgmtOpticalPortNotifyEnable objects.
+ "
+ ::={ rosMgmtOpticalTransceiverNotifications 17 }
+
+rosMgmtOpticalTransceiverParamLowWarningNormalTrap NOTIFICATION-TYPE
+ OBJECTS { rosMgmtOpticalTransceiverParameterValue,
+ rosMgmtOpticalTransceiverParamAlarmStatus }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when the optical module parameter value increase to above
+ the high alarm threshold or dicrease to under the low alarm threshold.
+
+
+ This notification may be suppressed under the following
+ conditions:
+ - depending on the value of the rosMgmtOpticalNotifyEnable and rosMgmtOpticalPortNotifyEnable objects.
+ "
+ ::={ rosMgmtOpticalTransceiverNotifications 18 }
+
+rosMgmtOpticalTransceiverTxFaultTrap NOTIFICATION-TYPE
+ OBJECTS { rosMgmtOpticalTransceiverTxFaultStatus }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when the SFP optical module occures Tx-fault signal.
+
+ This notification may be suppressed under the following
+ conditions:
+ - depending on the value of the rosMgmtOpticalNotifyEnable and rosMgmtOpticalPortNotifyEnable objects.
+ "
+ ::={ rosMgmtOpticalTransceiverNotifications 19 }
+
+rosMgmtOpticalTransceiverTxNormalTrap NOTIFICATION-TYPE
+ OBJECTS { rosMgmtOpticalTransceiverTxFaultStatus }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when the SFP optical module cancels the Tx-fault signal.
+
+ This notification may be suppressed under the following
+ conditions:
+ - depending on the value of the rosMgmtOpticalNotifyEnable and rosMgmtOpticalPortNotifyEnable objects.
+ "
+ ::={ rosMgmtOpticalTransceiverNotifications 20 }
+
+-- Textual Conventions
+EnableVar ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "enable or disable a function."
+ SYNTAX INTEGER {
+ enable(1),
+ disable(2)
+ }
+
+OpticalParameterType ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "This value indicates the optical parameter that is
+ being monitored. Valid values are -OpticalParameterType
+
+ transceiverTemperature(1) :transceiver temperature
+ txbiasCurrent(2) :TX bias current
+ txPower(3) :TX output power
+ rxPower(4) :RX received optical power
+ laserTemperature(5) :laser temperature
+ p5V0supplyVoltage(6) :+5V supply voltage
+ p3V3supplyVoltage(7) :+3.3V supply voltage
+ p1V8supplyVoltage(8) :+1.8V supply voltage
+ n5V2supplyVoltage(9) :-5.2V supply voltage
+ apdBiasVoltage(10) :APD bias voltage
+ p5V0supplyCurrent(11) :+5V supply currnet
+ p3V3supplyCurrent(12) :+3.3V supply currnet
+ p1V8supplyCurrent(13) :+1.8V supply currnet
+ n5V2supplyCurrent(14) :-5.2V supply currnet
+ tecCurrent(15) :TEC currnet
+ laserWavelength(16) :laser wavelength
+
+ "
+
+ SYNTAX INTEGER {
+ transceiverTemperature (1),
+ txbiasCurrent (2),
+ txPower (3),
+ rxPower (4),
+ laserTemperature(5),
+ p5V0supplyVoltage(6),
+ p3V3supplyVoltage(7),
+ p1V8supplyVoltage(8),
+ n5V2supplyVoltage(9),
+ apdBiasVoltage(10),
+ p5V0supplyCurrent(11),
+ p3V3supplyCurrent(12),
+ p1V8supplyCurrent(13),
+ n5V2supplyCurrent(14),
+ tecCurrent(15),
+ laserWavelength(16)
+
+ }
+
+
+OpticalParameterValue ::= TEXTUAL-CONVENTION
+ DISPLAY-HINT "d-2"
+ STATUS current
+ DESCRIPTION
+ "The value of the optical parameter that is being monitored.
+ The range of values varies depending on the type of optical parameter being monitored,
+ as identified by a corresponding object with syntax OpticalParameterType.
+ When the optical parameter being monitored is 'XXTemperature',the supported range
+ is from -40000 to 125000, in units of 1/1000 degrees centigrade.
+ Example: A value of 23500 represents a temperature reading of 23.5 degrees C.
+ The temperature is shown in unit of degrees centigrade, and the precision is 0.1.
+ When the optical parameter being monitored is 'txbiasCurrent',the supported range
+ is from 0 to 131000, in units of 1/1000 mA.
+ Example: A value of 1000 represents a TX bias current reading of 1.0mA.
+ The 'txbiasCurrent'is shown in unit of mA, and the precision is 0.1.
+ When the optical parameter being monitored is 'txPower',the supported range
+ is from -40000 to 8200, in units of 1/1000 dbm.
+ Example: A value of 77800 represents a TX output power reading of 7.78 dBm.
+ The 'txPower' is shown in unit of dBm, and the precision is 0.1.
+ When the optical parameter being monitored is 'rxPower',the supported range
+ is from -40000 to 8200, in units of 1/1000 dbm.
+ Example: A value of 7780 represents a RX received optical power reading of 7.78 dBm.
+ The 'rxPower' is shown in unit of dBm, and the precision is 0.1.
+ When the optical parameter being monitored is 'XXsupplyVoltage',the supported range
+ is from 0 to 6550, in units of 1/1000 V.
+ Example: A value of 6000 represents a XX supply Voltage eading of 6.00V.
+ The 'XXsupplyVoltage'is shown in unit of V, and the precision is 0.01.
+ When the optical parameter being monitored is 'apdBiasVoltage,the supported range
+ is from 0 to 655300 , in units of 1/1000 V .
+ Example: A value of 600000 represents a APD BiasVoltage reading of 600.0V.
+ The 'apdBiasVoltage' is shown in unit of V, and the precision is 0.1.
+ When the optical parameter being monitored is 'XXsupplyCurrent',the supported range
+ is from 0 to 6553600, in units of 1/1000 mA .
+ Example: A value of 6000000 represents a XX supply current reading of 6000.0mA.
+ The 'XXsupplyCurrent' is shown in unit of mA, and the precision is 0.1.
+ When the optical parameter being monitored is 'tecCurrent',the supported range
+ is from 0 to 6553600, in units of 1/1000 mA .
+ Example: A value of 6000000 represents a TEC Current reading of 6000.0mA.
+ The 'tecCurrent' is shown in unit of mA, and the precision is 0.1.
+ When the optical parameter being monitored is 'laserWavelength,the supported range
+ is from 0 to 3276750, in units of 1/1000 nm .
+ Example: A value of 3000000 represents a laser wavelength reading of 3000.0nm.
+ The 'laserWavelength'is shown in unit of nm, and the precision is 0.01.
+ "
+ SYNTAX Integer32 (-1000000 | -40000..6553600)
+
+OpticalPMPeriod ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "This value indicates the time period over which performance
+ monitoring data has been collected."
+ SYNTAX INTEGER {
+ fifteenMin(1),
+ twentyFourHour(2)
+ }
+
+-- MIB Scalar Group Definitions
+
+rosMgmtOpticalTransceiverScalarGroup OBJECT IDENTIFIER ::=
+ {rosMgmtOpticalTransceiverObjects 1 }
+
+rosMgmtOpticalTransceiverNotifyEnable OBJECT-TYPE
+ SYNTAX EnableVar
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object specifies the generation of device notifications,
+ enable or disable.
+
+ this object belongs to xfp and sfp.
+ "
+ DEFVAL { disable }
+ ::={ rosMgmtOpticalTransceiverScalarGroup 1 }
+
+rosMgmtOpticalTransceiverDDMEnable OBJECT-TYPE
+ SYNTAX EnableVar
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable or disable digitaldiagnotic on the device.
+
+ this object belongs to xfp and sfp.
+ "
+ DEFVAL { disable}
+ ::={ rosMgmtOpticalTransceiverScalarGroup 2 }
+
+rosMgmtOpticalTransceiverCheckPwdEnable OBJECT-TYPE
+ SYNTAX EnableVar
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object specifies the status of password checking on the device,
+ enable or disable.
+
+ this object belongs to xfp.
+ "
+ DEFVAL { disable}
+ ::={ rosMgmtOpticalTransceiverScalarGroup 3 }
+
+rosMgmtOpticalTransceiverPollInterval OBJECT-TYPE
+ SYNTAX Integer32 (5..15)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object specifies the value of poll-interval on the device.
+
+ this object belongs to xfp and sfp.
+ "
+ ::={ rosMgmtOpticalTransceiverScalarGroup 4 }
+
+rosMgmtOpticalTransceiverCRCCheckEnable OBJECT-TYPE
+ SYNTAX EnableVar
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object specifies the status of crc checking on the device,
+ enable or disable.
+
+ this object belongs to sfp and xfp.
+ "
+ DEFVAL { disable}
+ ::={ rosMgmtOpticalTransceiverScalarGroup 5 }
+-- MIB Object Definitions
+
+rosMgmtOpticalTransceiverCfgObjects OBJECT IDENTIFIER ::=
+ {rosMgmtOpticalTransceiverObjects 2 }
+
+-- groups in this MIB module
+rosMgmtOpticalTransceiverInfoGroup OBJECT IDENTIFIER ::=
+ {rosMgmtOpticalTransceiverCfgObjects 1 }
+
+rosMgmtOpticalTransceiverDDMGroup OBJECT IDENTIFIER ::=
+ {rosMgmtOpticalTransceiverCfgObjects 2 }
+
+rosMgmtOpticalTransceiverPMGroup OBJECT IDENTIFIER ::=
+ {rosMgmtOpticalTransceiverCfgObjects 3 }
+
+rosMgmtOpticalTransceiverStatusGroup OBJECT IDENTIFIER ::=
+ {rosMgmtOpticalTransceiverCfgObjects 4 }
+
+-- rosMgmtOpticalTransceiverInfoTable
+
+rosMgmtOpticalTransceiverInfoTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF RosMgmtOpticalTransceiverInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Trancetver information Table."
+ ::= { rosMgmtOpticalTransceiverInfoGroup 1 }
+
+rosMgmtOpticalTransceiverInfoEntry OBJECT-TYPE
+ SYNTAX RosMgmtOpticalTransceiverInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry in the rosMgmtOpticalTransceiverInfoTable."
+ INDEX { ifIndex }
+ ::={ rosMgmtOpticalTransceiverInfoTable 1 }
+
+
+RosMgmtOpticalTransceiverInfoEntry ::= SEQUENCE {
+ rosMgmtOpticalTransceiverType INTEGER,
+ rosMgmtOpticalTransceiverConnectorType INTEGER,
+ rosMgmtOpticalTransceiverVendorName OCTET STRING,
+ rosMgmtOpticalTransceiverVendorPN OCTET STRING,
+ rosMgmtOpticalTransceiverVendorSN OCTET STRING,
+ rosMgmtOpticalTransceiverMediaType INTEGER,
+ rosMgmtOpticalTransceiverTransmissionDistance Integer32,
+ rosMgmtOpticalTransceiverAbility Unsigned32,
+ rosMgmtOpticalTransceiverDDM INTEGER,
+ rosMgmtOpticalTransceiverCalibrationType INTEGER,
+ rosMgmtOpticalTransceiverRSSI INTEGER,
+ rosMgmtOpticalTransceiverVendorRev OCTET STRING,
+ rosMgmtOpticalTransceiverBRMax Integer32,
+ rosMgmtOpticalTransceiverBRMin Integer32,
+ rosMgmtOpticalTransceiverWavelengthContrl INTEGER,
+ rosMgmtOpticalTransceiverWavelength Integer32,
+ rosMgmtOpticalTransceiverWaveTolerance Integer32,
+ rosMgmtOpticalTransceiverCompatibility OCTET STRING,
+ rosMgmtOpticalTransceiverPowerDissipation INTEGER,
+ rosMgmtOpticalTransceiverCDR INTEGER,
+ rosMgmtOpticalTransceiverRefClock INTEGER,
+ rosMgmtOpticalTransceiverTransmitterType INTEGER,
+ rosMgmtOpticalTransceiverCooled INTEGER,
+ rosMgmtOpticalTransceiverTunalbe INTEGER,
+ rosMgmtOpticalTransceiverDetectorType INTEGER,
+ rosMgmtOpticalTransceiverLineLoopBack INTEGER,
+ rosMgmtOpticalTransceiverXFILoopBack INTEGER,
+ rosMgmtOpticalTransceiverVps INTEGER,
+ rosMgmtOpticalTransceiverTxDis INTEGER,
+ rosMgmtOpticalTransceiverStandby INTEGER,
+ rosMgmtOpticalTransceiverInVpsLowPower INTEGER,
+ rosMgmtOpticalTransceiverOutVpsLowPower INTEGER,
+ rosMgmtOpticalTransceiverFEC INTEGER,
+ rosMgmtOpticalTransceiverCMU INTEGER,
+ rosMgmtOpticalTransceiverBR INTEGER
+
+}
+
+rosMgmtOpticalTransceiverType OBJECT-TYPE
+ SYNTAX INTEGER{
+ unknown(1),
+ gbic(2),
+ soldered(3),
+ sfp(4),
+ xbi(5),
+ xenpak(6),
+ xfp(7),
+ xff(8),
+ xfpe(9),
+ xpak(10),
+ x2(11),
+ sfpj(12),
+ qsfp(14),
+ qsfp28(18)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object specifies the physical type of the transceiver,
+ such as xfp or sfp , and so on.
+
+ this object belongs to xfp and sfp.
+ "
+ ::= { rosMgmtOpticalTransceiverInfoEntry 1 }
+
+rosMgmtOpticalTransceiverConnectorType OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ unknown(1),
+ sc (2),
+ db9(3),
+ hssdc(4),
+ bnctnc(5),
+ fibercoaxialhead(6),
+ fiberjack(7),
+ lc(8),
+ mtrj(9),
+ mu(10),
+ sg(11),
+ fiberpigtail(12),
+ mpoparalleloptic(13),
+ hssdcII (14),
+ copper (15),
+ rj45 (16)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object specifies the connector type of the transceiver,
+ unknown, sc, db9, hssdc, bnc_tnc, fiber_coaxial_head, fiber_outlet,
+ lc, mt_rj, mu, sg, fiber_pigtail, mpo_parallel_optic , hssdcII,
+ copper, rj45.
+
+ this object belongs to xfp and sfp.
+ "
+ ::= { rosMgmtOpticalTransceiverInfoEntry 2 }
+
+rosMgmtOpticalTransceiverVendorName OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Vendor name of the interface.
+
+ this object belongs to xfp and sfp.
+ "
+ ::= { rosMgmtOpticalTransceiverInfoEntry 3 }
+
+rosMgmtOpticalTransceiverVendorPN OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Vendor part number of the interface.
+
+ this object belongs to xfp and sfp.
+ "
+ ::= { rosMgmtOpticalTransceiverInfoEntry 4 }
+
+rosMgmtOpticalTransceiverVendorSN OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Vendor serial number of the interface.
+
+ this object belongs to xfp and sfp.
+ "
+ ::= { rosMgmtOpticalTransceiverInfoEntry 5 }
+
+rosMgmtOpticalTransceiverMediaType OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ singlemode(1),
+ multimodeE50(2),
+ multimode50(3),
+ multimode625(4),
+ copper(5),
+ singlemodeKm(6),
+ multimodeOM3(7),
+ multimodeOM3Qsfp(8),
+ multimodeOM2Qsfp(9),
+ multimodeOM1Qsfp(10),
+ multimodeOM4Qsfp(11)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Types of the fiber,
+ single_mode, multi_modeE50, multi_mode50,multi_mode625,copper,
+ single_modeKm,multi_modeOM3,multi_modeOM3Qsfp,multi_modeOM2Qsfp,
+ multi_modeOM1Qsfp,multi_modeOM4Qsfp.
+
+ this object belongs to xfp, sfp and qsfp.
+ "
+ ::= { rosMgmtOpticalTransceiverInfoEntry 6 }
+
+rosMgmtOpticalTransceiverTransmissionDistance OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The max distance which the interface could transmit,
+ measured in meter.
+ The object will be shown in unit of Km, and the precision is 0.001.
+
+ this object belongs to xfp and sfp.
+ "
+ ::= { rosMgmtOpticalTransceiverInfoEntry 7 }
+
+rosMgmtOpticalTransceiverAbility OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object specifies the ability of optical module digitaldiagnotic
+ funtion. Currently, the digitaldiagnotic objects of our optical module
+ inculde 16 parameters.
+
+ this object has 32 bits, each bit represents a digital diagnotic parameter.
+ if the bit value is 0, it means that the optical module does not provide
+ digital diagnotic funtion for relative parameter.if the bit value is 1,it
+ means that the optical module provides digital diagnotic funtion for
+ relative parameter.
+
+ this object belongs to xfp and sfp.
+
+ The relation between parameters and bits is following:
+ 32...16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1:
+ The relation between parameters and bits is following:
+ 32...16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1:
+ | 1bit | 2bit | 3bit | 4bit
+ | APD Bias voltage | 0(reserve) | TEC Current | Laser temperature
+
+ | 5bit | 6bit |7bit | 8bit
+ | Laser wavelength | +5V Supply voltage | +3.3V Supply voltage | +1.8V Supply voltage
+
+ | 9bit | 10bit |11bit | 12bit
+ | -5.2V Supply voltage | +5V Supply current | 0(None) | 0(None)
+
+ | 13bit | 14bit | 15bit | 16bit
+ | +3.3V Supply current | +1.8V Supply current | -5.2V Supply current | temperature
+
+ | 17bit | 18bit | 19bit | 20bit ~ 32bit
+ | Laser bias current | Rx power |Tx power | 0
+
+ But when the optical module is sfp, the 6 bit will represents
+ the supplyVoltage of sfp.
+ "
+ ::= { rosMgmtOpticalTransceiverInfoEntry 8 }
+
+rosMgmtOpticalTransceiverDDM OBJECT-TYPE
+ SYNTAX INTEGER{
+ support(1),
+ notsupport(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object specifies if the transceiver supports on digital diagnostic function,
+ support or not support.To the xfp, the default value of this object is support.
+
+ this object belongs to xfp and sfp.
+ "
+ ::= { rosMgmtOpticalTransceiverInfoEntry 9 }
+
+rosMgmtOpticalTransceiverCalibrationType OBJECT-TYPE
+ SYNTAX INTEGER{
+ unknown(1),
+ internal(2),
+ external(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object specifies the calibration type of the transceiver,
+ internal, external, unknown.
+
+ this object belongs to xfp and sfp.
+ "
+ ::= { rosMgmtOpticalTransceiverInfoEntry 10 }
+
+rosMgmtOpticalTransceiverRSSI OBJECT-TYPE
+ SYNTAX INTEGER{
+ support(1),
+ notsupport(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object specifies the calibration type of the transceiver,
+ support or not support.
+
+ this object belongs to xfp and sfp.
+ "
+ ::= { rosMgmtOpticalTransceiverInfoEntry 11 }
+
+rosMgmtOpticalTransceiverVendorRev OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ " the version number of the transceiver.
+ this object belongs to xfp and sfp.
+ "
+ ::= { rosMgmtOpticalTransceiverInfoEntry 12 }
+
+rosMgmtOpticalTransceiverBRMax OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ " the min data rate of the transceiver,mesured in Mbps .
+ this object belongs to xfp and sfp.
+
+ The object will be shown in unit of Gbps, and the precision is 0.1.
+ "
+ ::= { rosMgmtOpticalTransceiverInfoEntry 13 }
+
+rosMgmtOpticalTransceiverBRMin OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ " the min data rate of the transceiver,mesured in Mbps.
+
+ this object belongs to xfp and sfp.To the sfp,
+ the min data rate value is equal to the max data rate value.
+
+ The object will be shown in unit of Gbps, and the precision is 0.1.
+ "
+ ::= { rosMgmtOpticalTransceiverInfoEntry 14 }
+
+rosMgmtOpticalTransceiverWavelengthContrl OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ support(1),
+ notsupport (2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "if the transceiver supports on wavelength control
+ support,notsupport.
+ this object belongs to xfp.
+ "
+ ::= { rosMgmtOpticalTransceiverInfoEntry 15 }
+
+rosMgmtOpticalTransceiverWavelength OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wavelength of the interface, measured in pm(0.001nm).
+ this object belongs to xfp.
+ The object will be shown in unit of nm, and the precision is 0.01.
+ "
+ ::= { rosMgmtOpticalTransceiverInfoEntry 16 }
+
+rosMgmtOpticalTransceiverWaveTolerance OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "the range of laser wavelength from nominal wavelength,mesured in pm(0.001*nm).
+ this object belongs to xfp.
+ The object will be shown in unit of nm, and the precision is 0.01.
+ "
+ ::= { rosMgmtOpticalTransceiverInfoEntry 17 }
+
+rosMgmtOpticalTransceiverCompatibility OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "the compatibility type that the transceiver supports,such as 10GBASE-SR.
+ this object belongs to xfp.
+ "
+ ::= { rosMgmtOpticalTransceiverInfoEntry 18 }
+
+rosMgmtOpticalTransceiverPowerDissipation OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ p1W5(1),
+ p2W5(2),
+ p3W5(3),
+ exceed(4)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "the max power dissipation of the transceiver,
+ p1W5,p2W5,p3W5,exceed3W5.
+ this object belongs to xfp.
+ "
+ ::= { rosMgmtOpticalTransceiverInfoEntry 19 }
+
+rosMgmtOpticalTransceiverCDR OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ support(1),
+ notsupport(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "the optical module supports on CDR fundtion.
+ support,notsupport.
+ this object belongs to xfp.
+ "
+ ::= { rosMgmtOpticalTransceiverInfoEntry 20 }
+
+rosMgmtOpticalTransceiverRefClock OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ required(1),
+ notrequired (2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ " if the transceiver requires outside reference clock
+ required,notrequired.
+ this object belongs to xfp.
+ "
+ ::= { rosMgmtOpticalTransceiverInfoEntry 21 }
+
+rosMgmtOpticalTransceiverTransmitterType OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ vcsel850nm(1),
+ vcsel1310nm(2),
+ vcsel1550nm(3),
+ fp1310nm(4),
+ dfb1310nm(5),
+ dfb1550nm(6),
+ eml1310nm(7),
+ eml1550nm(8),
+ copperothers(9)
+ }
+
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The transmitter type of the transceiver,such as 850 nm VCSEL.
+ this object belongs to xfp.
+ "
+ ::= { rosMgmtOpticalTransceiverInfoEntry 22 }
+
+rosMgmtOpticalTransceiverCooled OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ cooled(1),
+ uncooled (2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The transmitter cooled type of the transceiver
+ cooled,uncooled.
+ this object belongs to xfp.
+ "
+ ::= { rosMgmtOpticalTransceiverInfoEntry 24 }
+
+rosMgmtOpticalTransceiverTunalbe OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ tunable (1),
+ untunable (2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The transmitter tunable type of the transceiver
+ tunable,untunable.
+ this object belongs to xfp.
+ "
+ ::= { rosMgmtOpticalTransceiverInfoEntry 25 }
+
+rosMgmtOpticalTransceiverDetectorType OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ pin(1),
+ apd(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The detector type of the transceiver
+ pin, apd.
+ this object belongs to xfp.
+ "
+ ::= { rosMgmtOpticalTransceiverInfoEntry 26 }
+
+rosMgmtOpticalTransceiverLineLoopBack OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ support(1),
+ notsupport(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The transceiver support status of sideline loop-back control
+ support,notsupport.
+ this object belongs to xfp.
+ "
+ ::= { rosMgmtOpticalTransceiverInfoEntry 27 }
+
+rosMgmtOpticalTransceiverXFILoopBack OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ support(1),
+ notsupport(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The transceiver support status of XFI loop-back control
+ support,notsupport.
+ this object belongs to xfp.
+ "
+ ::= { rosMgmtOpticalTransceiverInfoEntry 28 }
+
+rosMgmtOpticalTransceiverVps OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ support(1),
+ notsupport(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object specifies if the optical module supports on VPS
+ support,notsupport.
+ this object belongs to xfp.
+ "
+ ::= { rosMgmtOpticalTransceiverInfoEntry 29 }
+
+rosMgmtOpticalTransceiverTxDis OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ support(1),
+ notsupport(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The transceiver support status of software control the transmitter status
+ support,notsupport.
+ this object belongs to xfp.
+ "
+ ::= { rosMgmtOpticalTransceiverInfoEntry 30 }
+
+rosMgmtOpticalTransceiverStandby OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ support(1),
+ notsupport(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The transceiver support status of software control the standby mode.
+ support,notsupport.
+ this object belongs to xfp.
+ "
+ ::= { rosMgmtOpticalTransceiverInfoEntry 31 }
+
+rosMgmtOpticalTransceiverInVpsLowPower OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ support(1),
+ notsupport(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The VPS in low power support status of the transceiver
+ support,notsupport.
+ this object belongs to xfp.
+ "
+ ::= { rosMgmtOpticalTransceiverInfoEntry 32 }
+
+rosMgmtOpticalTransceiverOutVpsLowPower OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ support(1),
+ notsupport(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The VPS out low power support status of the transceiver
+ support,notsupport.
+ this object belongs to xfp.
+ "
+ ::= { rosMgmtOpticalTransceiverInfoEntry 33 }
+
+rosMgmtOpticalTransceiverFEC OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ support(1),
+ notsupport(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The FEC support status of transceiver
+ support,notsupport.
+ this object belongs to xfp.
+ "
+ ::= { rosMgmtOpticalTransceiverInfoEntry 34 }
+
+rosMgmtOpticalTransceiverCMU OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ support(1),
+ notsupport(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The CMU support status of transceiver
+ support,notsupport.
+ this object belongs to xfp.
+ "
+ ::= { rosMgmtOpticalTransceiverInfoEntry 35 }
+
+rosMgmtOpticalTransceiverBR OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ unknown(0),
+ bitrate125Mbps(1),
+ bitrate155Mbps (2),
+ bitrate622Mbps(6),
+ bitrate1250Mbps(12),
+ bitrate1DOT25Gbps(13),
+ bitrate2DOT5Gbps(19),
+ bitrate10GbpsOr100Gbps1(103),
+ bitrate100Gbps2(114),
+ bitrate25Gbps(255)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object specifies the Nominal bitrate of the transceiver,
+ 125Mbps, 155Mbps, 622Mbps, 1.25Gbps, 2.5Gbps, 10Gbps, 100Gbps, 25Gbps.
+
+ this object belongs to xfp and sfp and qsfp and qsfp28.
+ "
+ ::= { rosMgmtOpticalTransceiverInfoEntry 36 }
+
+-- rosMgmtOpticalDDMTable
+
+rosMgmtOpticalTransceiverDDMTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF RosMgmtOpticalTransceiverDDMEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table provides objects to monitor optical
+ parameters in a network element. "
+ ::={ rosMgmtOpticalTransceiverDDMGroup 1 }
+
+rosMgmtOpticalTransceiverDDMEntry OBJECT-TYPE
+ SYNTAX RosMgmtOpticalTransceiverDDMEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry in the rosMgmtOpticalTransceiverMonTable provides objects to
+ monitor an optical parameter at an optical interface.
+ "
+ INDEX { ifIndex,
+ rosMgmtOpticalTransceiverParameterType
+ }
+ ::={ rosMgmtOpticalTransceiverDDMTable 1 }
+
+RosMgmtOpticalTransceiverDDMEntry ::= SEQUENCE {
+ rosMgmtOpticalTransceiverParameterType OpticalParameterType,
+-- rosMgmtOpticalTransceiverOPType INTEGER,
+ rosMgmtOpticalTransceiverParameterValue OpticalParameterValue,
+ rosMgmtOpticalTransceiverParamHighAlarmThresh OpticalParameterValue,
+ rosMgmtOpticalTransceiverParamHighWarningThresh OpticalParameterValue,
+ rosMgmtOpticalTransceiverParamLowAlarmThresh OpticalParameterValue,
+ rosMgmtOpticalTransceiverParamLowWarningThresh OpticalParameterValue,
+ rosMgmtOpticalTransceiverParamAlarmStatus INTEGER,
+ rosMgmtOpticalTransceiverParamAlarmLastValue OpticalParameterValue,
+ rosMgmtOpticalTransceiverParamAlarmLastChange TimeTicks,
+ rosMgmtOpticalTransceiverDDM15MinValidIntervals Unsigned32,
+ rosMgmtOpticalTransceiverDDM24HrValidIntervals Unsigned32,
+ rosMgmtOpticalTransceiverDDMValidStatus INTEGER,
+ rosMgmtOpticalTransceiverQsfpParameterValue OCTET STRING,
+ rosMgmtOpticalTransceiverQsfpParamHighAlarmThresh OCTET STRING,
+ rosMgmtOpticalTransceiverQsfpParamHighWarningThresh OCTET STRING,
+ rosMgmtOpticalTransceiverQsfpParamLowAlarmThresh OCTET STRING,
+ rosMgmtOpticalTransceiverQsfpParamLowWarningThresh OCTET STRING,
+ rosMgmtOpticalTransceiverQsfpParamAlarmStatus OCTET STRING,
+ rosMgmtOpticalTransceiverQsfpParamAlarmLastValue OCTET STRING,
+ rosMgmtOpticalTransceiverQsfpParamAlarmLastChange OCTET STRING,
+ rosMgmtOpticalTransceiverQsfpDDM15MinValidIntervals OCTET STRING,
+ rosMgmtOpticalTransceiverQsfpDDM24HrValidIntervals OCTET STRING,
+ rosMgmtOpticalTransceiverQsfpDDMValidStatus OCTET STRING
+}
+
+rosMgmtOpticalTransceiverParameterType OBJECT-TYPE
+ SYNTAX OpticalParameterType
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This object specifies the optical parameter that is being
+ monitored in this entry.
+ This object belongs to xfp/sfp.
+ "
+ ::={ rosMgmtOpticalTransceiverDDMEntry 1 }
+
+--rosMgmtOpticalTransceiverOPType OBJECT-TYPE
+-- SYNTAX INTEGER
+-- {
+-- others(1),
+-- sfp(2),
+-- xfp(3),
+-- sfpj(4),
+-- qsfp(5)
+-- }
+
+-- MAX-ACCESS read-only
+-- STATUS current
+-- DESCRIPTION
+-- "This object specifies the optical type "
+-- ::={ rosMgmtOpticalTransceiverDDMEntry 2 }
+
+rosMgmtOpticalTransceiverParameterValue OBJECT-TYPE
+ SYNTAX OpticalParameterValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object gives the value measured for the particular
+ optical parameter specified by the rosMgmtOpticalMonParameterType
+ object.
+ This object belongs to xfp/sfp.
+ "
+ ::={ rosMgmtOpticalTransceiverDDMEntry 2 }
+
+rosMgmtOpticalTransceiverParamHighAlarmThresh OBJECT-TYPE
+ SYNTAX OpticalParameterValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object gives the high alarm threshold on the
+ optical parameter being monitored.
+
+ An alarm condition will be raised if the value given by
+ rosMgmtOpticalParameterValue goes from below the value of
+ this object to above the value of this object, or if
+ the initial value of rosMgmtOpticalParameterValue exceeds the value
+ of this object. This alarm will be indicated in the
+ rosMgmtOpticalParamAlarmStatus object.
+ This object belongs to xfp/sfp.
+ "
+ ::={ rosMgmtOpticalTransceiverDDMEntry 3 }
+
+rosMgmtOpticalTransceiverParamHighWarningThresh OBJECT-TYPE
+ SYNTAX OpticalParameterValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object is used to set a high warning threshold on
+ the optical parameter being monitored.
+
+ A threshold crossing condition will be indicated if the value
+ given by rosMgmtOpticalParameterValue goes from below the value
+ of this object to above the value of this
+ object, or if the initial value of rosMgmtOpticalParameterValue
+ exceeds the value of this object. This alarm will be indicated in the
+ rosMgmtOpticalParamAlarmStatus object.
+ This object belongs to xfp/sfp.
+ "
+ ::={ rosMgmtOpticalTransceiverDDMEntry 4 }
+
+rosMgmtOpticalTransceiverParamLowAlarmThresh OBJECT-TYPE
+ SYNTAX OpticalParameterValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object is used to set a low alarm threshold on the
+ optical parameter being monitored.
+
+ An alarm condition will be raised if the value given by
+ rosMgmtOpticalParameterValue goes from above the value of
+ this object to below the value of this object, or if
+ the initial value of rosMgmtOpticalParameterValue is lower than the
+ value of this object. This alarm
+ will be indicated in the rosMgmtOpticalParamAlarmStatus object ..
+ This object belongs to xfp/sfp.
+ "
+ ::={ rosMgmtOpticalTransceiverDDMEntry 5 }
+
+rosMgmtOpticalTransceiverParamLowWarningThresh OBJECT-TYPE
+ SYNTAX OpticalParameterValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object is used to set a low warning threshold on
+ the optical parameter being monitored.
+
+ A threshold crossing condition will be indicated if the value
+ given by rosMgmtOpticalParameterValue goes from above the value
+ of this object to below the value of this
+ object, or if the initial value of rosMgmtOpticalParameterValue
+ object is lower than the value of this object. For
+ network elements in the status
+ indications, this threshold violation will be indicated in the
+ rosMgmtOpticalParamAlarmStatus object .
+ This object belongs to xfp/sfp.
+ "
+ ::={ rosMgmtOpticalTransceiverDDMEntry 6 }
+
+rosMgmtOpticalTransceiverParamAlarmStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal(1),
+ highalarm(2),
+ highwarning(3),
+ lowalarm(4),
+ lowwarning(5)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object is used to indicate the current status of
+ the thresholds for the monitored optical parameter
+ on the interface.
+
+ If a threshold is currently being exceeded on the
+ interface, the object will be set. Otherwise,
+ the object will be set to 1.
+ This object belongs to xfp/sfp.
+ "
+ ::={ rosMgmtOpticalTransceiverDDMEntry 7 }
+
+rosMgmtOpticalTransceiverParamAlarmLastValue OBJECT-TYPE
+ SYNTAX OpticalParameterValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object indicates the optical parameter value at the last time
+ a threshold related to a particular optical parameter was
+ exceeded on the interface.
+ If no threshold value is currently being
+ exceeded, then the value '-1000000' is returned.
+
+ This object belongs to xfp/sfp.
+ "
+ ::={ rosMgmtOpticalTransceiverDDMEntry 8 }
+
+rosMgmtOpticalTransceiverParamAlarmLastChange OBJECT-TYPE
+ SYNTAX TimeTicks
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object specifies the value of sysUpTime at the last time
+ a threshold related to a particular optical parameter was
+ exceeded on the interface.
+
+ This object belongs to xfp/sfp.
+ "
+ ::={ rosMgmtOpticalTransceiverDDMEntry 9 }
+
+rosMgmtOpticalTransceiverDDM15MinValidIntervals OBJECT-TYPE
+ SYNTAX Unsigned32 (0..96)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object gives the number of previous 15 minute
+ intervals for which valid performance monitoring data
+ has been stored on the interface.
+
+ The value of this object will be n (where n is the maximum
+ number of 15 minute intervals supported at this interface),
+ unless the measurement was (re-)started within the last
+ (nx15) minutes, in which case the value will be the
+ number of previous 15 minute intervals for which the agent
+ has some data.
+
+ This object belongs to xfp/sfp.
+ "
+ ::={ rosMgmtOpticalTransceiverDDMEntry 10 }
+
+rosMgmtOpticalTransceiverDDM24HrValidIntervals OBJECT-TYPE
+ SYNTAX Unsigned32 (0..7)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object gives the number of previous 24 hour intervals
+ for which valid performance monitoring data has been stored
+ on the interface. The max value of this object is 7, it
+ means that the user can look up 7days history information.
+ This object belongs to xfp/sfp.
+ "
+ ::={ rosMgmtOpticalTransceiverDDMEntry 11 }
+
+rosMgmtOpticalTransceiverDDMValidStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ valid(1),
+ invalid(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object indicates the parameter row is valid or invalid.
+ The object value is 'valide' when the module is present and
+ supporting digitaldiagnotic. The object value is 'invalid'
+ when the module is absent, or when the module is present and
+ not supporting digitaldiagnotic.
+ This object belongs to xfp/sfp.
+ "
+ ::={ rosMgmtOpticalTransceiverDDMEntry 12 }
+rosMgmtOpticalTransceiverQsfpParameterValue OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object gives the value measured for the particular
+ optical parameter specified by the rosMgmtOpticalMonParameterType
+ object.
+ This object belongs to Qsfp.
+ "
+ ::={ rosMgmtOpticalTransceiverDDMEntry 13 }
+
+rosMgmtOpticalTransceiverQsfpParamHighAlarmThresh OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object gives the high alarm threshold on the
+ optical parameter being monitored.
+
+ An alarm condition will be raised if the value given by
+ rosMgmtOpticalParameterValue goes from below the value of
+ this object to above the value of this object, or if
+ the initial value of rosMgmtOpticalParameterValue exceeds the value
+ of this object. This alarm will be indicated in the
+ rosMgmtOpticalParamAlarmStatus object.
+ This object belongs to Qsfp.
+ "
+ ::={ rosMgmtOpticalTransceiverDDMEntry 14 }
+
+rosMgmtOpticalTransceiverQsfpParamHighWarningThresh OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object is used to set a high warning threshold on
+ the optical parameter being monitored.
+
+ A threshold crossing condition will be indicated if the value
+ given by rosMgmtOpticalParameterValue goes from below the value
+ of this object to above the value of this
+ object, or if the initial value of rosMgmtOpticalParameterValue
+ exceeds the value of this object. This alarm will be indicated in the
+ rosMgmtOpticalParamAlarmStatus object.
+ This object belongs to Qsfp.
+ "
+ ::={ rosMgmtOpticalTransceiverDDMEntry 15 }
+
+rosMgmtOpticalTransceiverQsfpParamLowAlarmThresh OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object is used to set a low alarm threshold on the
+ optical parameter being monitored.
+
+ An alarm condition will be raised if the value given by
+ rosMgmtOpticalParameterValue goes from above the value of
+ this object to below the value of this object, or if
+ the initial value of rosMgmtOpticalParameterValue is lower than the
+ value of this object. This alarm
+ will be indicated in the rosMgmtOpticalParamAlarmStatus object ..
+ This object belongs to Qsfp.
+ "
+ ::={ rosMgmtOpticalTransceiverDDMEntry 16 }
+
+rosMgmtOpticalTransceiverQsfpParamLowWarningThresh OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object is used to set a low warning threshold on
+ the optical parameter being monitored.
+
+ A threshold crossing condition will be indicated if the value
+ given by rosMgmtOpticalParameterValue goes from above the value
+ of this object to below the value of this
+ object, or if the initial value of rosMgmtOpticalParameterValue
+ object is lower than the value of this object. For
+ network elements in the status
+ indications, this threshold violation will be indicated in the
+ rosMgmtOpticalParamAlarmStatus object .
+ This object belongs to Qsfp.
+ "
+ ::={ rosMgmtOpticalTransceiverDDMEntry 17 }
+
+rosMgmtOpticalTransceiverQsfpParamAlarmStatus OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object is used to indicate the current status of
+ the thresholds for the monitored optical parameter
+ on the interface.
+
+ If a threshold is currently being exceeded on the
+ interface, the object will be set. Otherwise,
+ the object will be set to 1.
+ This object belongs to Qsfp.
+ "
+ ::={ rosMgmtOpticalTransceiverDDMEntry 18 }
+
+rosMgmtOpticalTransceiverQsfpParamAlarmLastValue OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object indicates the optical parameter value at the last time
+ a threshold related to a particular optical parameter was
+ exceeded on the interface.
+ If no threshold value is currently being
+ exceeded, then the value '-1000000' is returned.
+
+ This object belongs to Qsfp.
+ "
+ ::={ rosMgmtOpticalTransceiverDDMEntry 19 }
+
+rosMgmtOpticalTransceiverQsfpParamAlarmLastChange OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object specifies the value of sysUpTime at the last time
+ a threshold related to a particular optical parameter was
+ exceeded on the interface.
+
+ This object belongs to Qsfp.
+ "
+ ::={ rosMgmtOpticalTransceiverDDMEntry 20 }
+
+rosMgmtOpticalTransceiverQsfpDDM15MinValidIntervals OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object gives the number of previous 15 minute
+ intervals for which valid performance monitoring data
+ has been stored on the interface.
+
+ The value of this object will be n (where n is the maximum
+ number of 15 minute intervals supported at this interface),
+ unless the measurement was (re-)started within the last
+ (nx15) minutes, in which case the value will be the
+ number of previous 15 minute intervals for which the agent
+ has some data.
+
+ This object belongs to Qsfp.
+ "
+ ::={ rosMgmtOpticalTransceiverDDMEntry 21 }
+
+rosMgmtOpticalTransceiverQsfpDDM24HrValidIntervals OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object gives the number of previous 24 hour intervals
+ for which valid performance monitoring data has been stored
+ on the interface. The max value of this object is 7, it
+ means that the user can look up 7days history information.
+ This object belongs to Qsfp.
+ "
+ ::={ rosMgmtOpticalTransceiverDDMEntry 22 }
+
+rosMgmtOpticalTransceiverQsfpDDMValidStatus OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object indicates the parameter row is valid or invalid.
+ The object value is 'valide' when the module is present and
+ supporting digitaldiagnotic. The object value is 'invalid'
+ when the module is absent, or when the module is present and
+ not supporting digitaldiagnotic.
+ This object belongs to Qsfp.
+ "
+ ::={ rosMgmtOpticalTransceiverDDMEntry 23 }
+
+-- rosMgmtOpticalTransceiverPMCurrent Table
+rosMgmtOpticalTransceiverPMCurrentTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF RosMgmtOpticalTransceiverPMCurrentEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table contains performance monitoring data for the
+ various optical parameters, collected over the current 15
+ minute or the current 24 hour interval."
+ ::={ rosMgmtOpticalTransceiverPMGroup 1 }
+
+rosMgmtOpticalTransceiverPMCurrentEntry OBJECT-TYPE
+ SYNTAX RosMgmtOpticalTransceiverPMCurrentEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry in the rosMgmtOpticalTransceiverPMCurrentTable. It contains
+ performance monitoring data for a monitored optical
+ parameter at an interface, collected over the current 15
+ minute or the current 24 hour interval.
+ "
+ INDEX { ifIndex,
+ rosMgmtOpticalTransceiverPMCurrentPeriod,
+ rosMgmtOpticalTransceiverPMCurrentParamType }
+ ::={ rosMgmtOpticalTransceiverPMCurrentTable 1 }
+
+RosMgmtOpticalTransceiverPMCurrentEntry ::= SEQUENCE {
+ rosMgmtOpticalTransceiverPMCurrentPeriod OpticalPMPeriod,
+ rosMgmtOpticalTransceiverPMCurrentParamType OpticalParameterType,
+-- rosMgmtOpticalTransceiverPMType INTEGER,
+ rosMgmtOpticalTransceiverPMCurrentMaxParam OpticalParameterValue,
+ rosMgmtOpticalTransceiverPMCurrentMinParam OpticalParameterValue,
+ rosMgmtOpticalTransceiverPMCurrentMeanParam OpticalParameterValue,
+ rosMgmtOpticalTransceiverQsfpPMCurrentMaxParam OCTET STRING,
+ rosMgmtOpticalTransceiverQsfpPMCurrentMinParam OCTET STRING,
+ rosMgmtOpticalTransceiverQsfpPMCurrentMeanParam OCTET STRING
+}
+
+rosMgmtOpticalTransceiverPMCurrentPeriod OBJECT-TYPE
+ SYNTAX OpticalPMPeriod
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This object indicates whether the optical parameter values
+ given in this entry are collected over the current 15 minute or
+ the current 24 hour interval.
+ This object belongs to xfp/sfp.
+ "
+ ::={ rosMgmtOpticalTransceiverPMCurrentEntry 1 }
+
+rosMgmtOpticalTransceiverPMCurrentParamType OBJECT-TYPE
+ SYNTAX OpticalParameterType
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This object specifies the optical parameter that is being
+ monitored, in this entry.
+ This object belongs to xfp/sfp.
+ "
+ ::={ rosMgmtOpticalTransceiverPMCurrentEntry 2 }
+-- rosMgmtOpticalTransceiverPMType OBJECT-TYPE
+-- SYNTAX INTEGER
+-- {
+-- others(1),
+-- sfp(2),
+-- xfp(3),
+-- sfpj(4),
+-- qsfp(5)
+-- }
+
+-- MAX-ACCESS read-only
+-- STATUS current
+-- DESCRIPTION
+-- "This object specifies the optical type "
+-- ::={ rosMgmtOpticalTransceiverPMCurrentEntry 3 }
+
+rosMgmtOpticalTransceiverPMCurrentMaxParam OBJECT-TYPE
+ SYNTAX OpticalParameterValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object gives the maximum value measured for the monitored
+ optical parameter, in the current 15 minute or the current
+ 24 hour interval.
+ This object belongs to xfp/sfp.
+ "
+ ::={ rosMgmtOpticalTransceiverPMCurrentEntry 3 }
+
+rosMgmtOpticalTransceiverPMCurrentMinParam OBJECT-TYPE
+ SYNTAX OpticalParameterValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object gives the minimum value measured for the monitored
+ optical parameter, in the current 15 minute or the current
+ 24 hour interval.
+ This object belongs to xfp/sfp.
+ "
+ ::={ rosMgmtOpticalTransceiverPMCurrentEntry 4 }
+
+rosMgmtOpticalTransceiverPMCurrentMeanParam OBJECT-TYPE
+ SYNTAX OpticalParameterValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object gives the average value of the monitored
+ optical parameter, in the current 15 minute or the current
+ 24 hour interval.
+ This object belongs to xfp/sfp.
+ "
+ ::={ rosMgmtOpticalTransceiverPMCurrentEntry 5 }
+rosMgmtOpticalTransceiverQsfpPMCurrentMaxParam OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object gives the maximum value measured for the monitored
+ optical parameter, in the current 15 minute or the current
+ 24 hour interval.
+ This object belongs to Qsfp
+ "
+ ::={ rosMgmtOpticalTransceiverPMCurrentEntry 6 }
+
+rosMgmtOpticalTransceiverQsfpPMCurrentMinParam OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object gives the minimum value measured for the monitored
+ optical parameter, in the current 15 minute or the current
+ 24 hour interval.
+ This object belongs to Qsfp.
+ "
+ ::={ rosMgmtOpticalTransceiverPMCurrentEntry 7 }
+
+rosMgmtOpticalTransceiverQsfpPMCurrentMeanParam OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object gives the average value of the monitored
+ optical parameter, in the current 15 minute or the current
+ 24 hour interval.
+ This object belongs to Qsfp.
+ "
+ ::={ rosMgmtOpticalTransceiverPMCurrentEntry 8 }
+
+
+-- rosMgmtOpticalTransceiverPMInterval Table
+
+rosMgmtOpticalTransceiverPMIntervalTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF RosMgmtOpticalTransceiverPMIntervalEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table stores performance monitoring data for the
+ various optical parameters, collected over previous
+ intervals.
+
+ This table can have entries for one complete 24 hour
+ interval and up to 96 complete 15 minute
+ intervals. A system is required to store at least
+ 4 completed 15 minute intervals. The number of valid
+ 15 minute intervals in this table is indicated by the
+ rosMgmtOpticalTransceiverDDM15MinValidIntervals object
+ and the number of valid 24 hour intervals is indicated by the
+ rosMgmtOpticalTransceiverDDM24HrValidIntervals object.
+
+ when the optical module is removed from the device, the relative
+ history records will be cleaned.
+ "
+ ::={ rosMgmtOpticalTransceiverPMGroup 2 }
+
+rosMgmtOpticalTransceiverPMIntervalEntry OBJECT-TYPE
+ SYNTAX RosMgmtOpticalTransceiverPMIntervalEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry in the rosMgmtOpticalTransceiverPMIntervalTable. It contains
+ performance monitoring data for an optical parameter,
+ collected over a previous interval.
+ "
+ INDEX { ifIndex,
+ rosMgmtOpticalTransceiverPMIntervalPeriod,
+ rosMgmtOpticalTransceiverPMIntervalNumber,
+ rosMgmtOpticalTransceiverPMIntervalParamType }
+ ::={ rosMgmtOpticalTransceiverPMIntervalTable 1 }
+
+RosMgmtOpticalTransceiverPMIntervalEntry ::= SEQUENCE {
+ rosMgmtOpticalTransceiverPMIntervalPeriod OpticalPMPeriod,
+ rosMgmtOpticalTransceiverPMIntervalNumber Integer32,
+ rosMgmtOpticalTransceiverPMIntervalParamType OpticalParameterType,
+-- rosMgmtOpticalTransceiverPMIntervalType INTEGER,
+ rosMgmtOpticalTransceiverPMIntervalMaxParam OpticalParameterValue,
+ rosMgmtOpticalTransceiverPMIntervalMinParam OpticalParameterValue,
+ rosMgmtOpticalTransceiverPMIntervalMeanParam OpticalParameterValue,
+ rosMgmtOpticalTransceiverQsfpPMIntervalMaxParam OCTET STRING,
+ rosMgmtOpticalTransceiverQsfpPMIntervalMinParam OCTET STRING,
+ rosMgmtOpticalTransceiverQsfpPMIntervalMeanParam OCTET STRING
+
+ }
+
+rosMgmtOpticalTransceiverPMIntervalPeriod OBJECT-TYPE
+ SYNTAX OpticalPMPeriod
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This object indicates whether the optical parameter values,
+ given in this entry, are collected over a period of 15 minutes
+ or 24 hours.
+ This object belongs to xfp/sfp.
+ "
+ ::={ rosMgmtOpticalTransceiverPMIntervalEntry 1 }
+
+rosMgmtOpticalTransceiverPMIntervalNumber OBJECT-TYPE
+ SYNTAX Integer32 (1..96)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A number between 1 and 96, which identifies the
+ interval for which the set of optical parameter values is
+ available. The interval identified by 1 is the most recently
+ completed 15 minute or 24 hour interval, and the interval
+ identified by N is the interval immediately preceding the one
+ identified by N-1.
+ This object belongs to xfp/sfp.
+ "
+ ::={ rosMgmtOpticalTransceiverPMIntervalEntry 2 }
+
+rosMgmtOpticalTransceiverPMIntervalParamType OBJECT-TYPE
+ SYNTAX OpticalParameterType
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This object specifies the optical parameter that is being
+ monitored, in this entry.
+ This object belongs to xfp/sfp.
+ "
+ ::={ rosMgmtOpticalTransceiverPMIntervalEntry 3 }
+
+--rosMgmtOpticalTransceiverPMIntervalType OBJECT-TYPE
+-- SYNTAX INTEGER
+-- {
+-- others(1),
+-- sfp(2),
+-- xfp(3),
+-- sfpj(4),
+-- qsfp(5)
+-- }
+
+-- MAX-ACCESS read-only
+-- STATUS current
+-- DESCRIPTION
+-- "This object specifies the optical type "
+-- ::={ rosMgmtOpticalTransceiverPMIntervalEntry 4 }
+
+rosMgmtOpticalTransceiverPMIntervalMaxParam OBJECT-TYPE
+ SYNTAX OpticalParameterValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object gives the maximum value measured for the optical
+ parameter, in a particular 15 minute or 24 hour interval.
+ This object belongs to xfp/sfp.
+ "
+ ::={ rosMgmtOpticalTransceiverPMIntervalEntry 4 }
+
+rosMgmtOpticalTransceiverPMIntervalMinParam OBJECT-TYPE
+ SYNTAX OpticalParameterValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object gives the minimum value measured for the optical
+ parameter, in a particular 15 minute or 24 hour interval.
+ This object belongs to xfp/sfp.
+ "
+ ::={ rosMgmtOpticalTransceiverPMIntervalEntry 5 }
+
+rosMgmtOpticalTransceiverPMIntervalMeanParam OBJECT-TYPE
+ SYNTAX OpticalParameterValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object gives the average value of the measured optical
+ parameter, in a particular 15 minute or 24 hour interval.
+ This object belongs to xfp/sfp.
+ "
+ ::={ rosMgmtOpticalTransceiverPMIntervalEntry 6 }
+rosMgmtOpticalTransceiverQsfpPMIntervalMaxParam OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object gives the maximum value measured for the optical
+ parameter, in a particular 15 minute or 24 hour interval.
+ This object belongs to Qsfp.
+ "
+ ::={ rosMgmtOpticalTransceiverPMIntervalEntry 7 }
+
+rosMgmtOpticalTransceiverQsfpPMIntervalMinParam OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object gives the minimum value measured for the optical
+ parameter, in a particular 15 minute or 24 hour interval.
+ This object belongs to Qsfp.
+ "
+ ::={ rosMgmtOpticalTransceiverPMIntervalEntry 8 }
+
+rosMgmtOpticalTransceiverQsfpPMIntervalMeanParam OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object gives the average value of the measured optical
+ parameter, in a particular 15 minute or 24 hour interval.
+ This object belongs to Qsfp.
+ "
+ ::={ rosMgmtOpticalTransceiverPMIntervalEntry 9 }
+
+-- rosMgmtOpticalTransceiverCurrentStatus Table
+rosMgmtOpticalTransceiverCurrentStatusTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF RosMgmtOpticalTransceiverCurrentStatusEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table stores the hard ware information and the information
+ set by user of the transceiver.
+ This object belongs to xfp/sfp.
+ "
+ ::={ rosMgmtOpticalTransceiverStatusGroup 1 }
+
+rosMgmtOpticalTransceiverCurrentStatusEntry OBJECT-TYPE
+ SYNTAX RosMgmtOpticalTransceiverCurrentStatusEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry in the rosMgmtOpticalTransceiverCurrentStatusTable. It contains
+ performance monitoring data for an optical parameter,
+ collected over a previous interval.
+ This object belongs to xfp/sfp.
+ "
+ INDEX { ifIndex }
+ ::={ rosMgmtOpticalTransceiverCurrentStatusTable 1 }
+
+RosMgmtOpticalTransceiverCurrentStatusEntry ::= SEQUENCE {
+ rosMgmtOpticalTransceiverHwInfoAbsStatus INTEGER,
+ rosMgmtOpticalTransceiverHwInfoNRStatus INTEGER,
+ rosMgmtOpticalTransceiverHwInfoRxLosStatus INTEGER,
+ rosMgmtOpticalTransceiverHwInfoStandby INTEGER,
+ rosMgmtOpticalTransceiverHwInfoLaser INTEGER,
+ rosMgmtOpticalTransceiverWaveLengthError Integer32,
+ rosMgmtOpticalTransceiverUserWaveLength Integer32,
+ rosMgmtOpticalTransceiverUserDataRate Integer32,
+ rosMgmtOpticalTransceiverUserLineLoopBack INTEGER,
+ rosMgmtOpticalTransceiverUserXFILoopBack INTEGER,
+ rosMgmtOpticalTransceiverPortNotifyEnable EnableVar,
+ rosMgmtOpticalTransceiverPortDDMEnable EnableVar,
+ rosMgmtOpticalTransceiverPortCheckPwdEnable EnableVar,
+ rosMgmtOpticalTransceiverTxFaultCount Integer32,
+ rosMgmtOpticalTransceiverTxFaultCountClear TruthValue,
+ rosMgmtOpticalTransceiverSpecificationCheckStatus INTEGER,
+ rosMgmtOpticalTransceiverTxFaultStatus INTEGER,
+
+ rosMgmtOpticalTransceiverPortCRCCheckEnable EnableVar,
+ rosMgmtOpticalTransceiverBaseCRCCheckStatus INTEGER,
+ rosMgmtOpticalTransceiverStaticDdmCRCCheckStatus INTEGER,
+ rosMgmtOpticalTransceiverDynamicDdmCRCCheckStatus INTEGER
+ }
+
+rosMgmtOpticalTransceiverHwInfoAbsStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ absent(1),
+ present(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object specifies if the optical module is absent
+ present,absent.
+ This object belongs to xfp and sfp."
+ ::={ rosMgmtOpticalTransceiverCurrentStatusEntry 1 }
+
+rosMgmtOpticalTransceiverHwInfoNRStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ ready(1),
+ notready(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object specifies if the optical module is ready for operation.
+ ready,notready.
+ This object belongs to xfp.
+ "
+ ::={ rosMgmtOpticalTransceiverCurrentStatusEntry 2 }
+
+rosMgmtOpticalTransceiverHwInfoRxLosStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ normal(1),
+ loss(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object specifies if the optical module operation losses the receiving signal
+ normal,loss.
+ This object belongs to xfp.
+ "
+ ::={ rosMgmtOpticalTransceiverCurrentStatusEntry 3 }
+
+rosMgmtOpticalTransceiverHwInfoStandby OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ normal(1),
+ standby(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object specifies if the optical module works under standby mode.
+ normal,standby.
+ This object belongs to xfp.
+ "
+ ::={ rosMgmtOpticalTransceiverCurrentStatusEntry 4 }
+
+rosMgmtOpticalTransceiverHwInfoLaser OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ on(1),
+ off(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object specifies if the optical module laser is turned on
+ on,off.
+ This object belongs to xfp.
+ "
+ ::={ rosMgmtOpticalTransceiverCurrentStatusEntry 5 }
+
+rosMgmtOpticalTransceiverWaveLengthError OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object specifies error between the actual wavelength
+ and the wavelength set by the user,measured in pm.
+ This object belongs to xfp.
+ The object will be shown in unit of nm, and the precision is 0.001.
+ "
+ ::={ rosMgmtOpticalTransceiverCurrentStatusEntry 6 }
+
+rosMgmtOpticalTransceiverUserWaveLength OBJECT-TYPE
+ SYNTAX Integer32(0..3276800)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object specifies the wavelength value of the optical module set by user,measured in pm.
+ This object belongs to xfp.
+ The object will be shown in unit of nm, and the precision is 0.01.
+ "
+ ::={ rosMgmtOpticalTransceiverCurrentStatusEntry 7 }
+
+
+rosMgmtOpticalTransceiverUserDataRate OBJECT-TYPE
+ SYNTAX Integer32(9500..12500)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object specifies the data rate of the optical module set by user,measured in Mbps.
+ This object belongs to xfp.
+ The object will be shown in unit of Gbps, and the precision is 0.1.
+ "
+ ::={ rosMgmtOpticalTransceiverCurrentStatusEntry 8 }
+
+rosMgmtOpticalTransceiverUserLineLoopBack OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ normal(1),
+ lineLoopback(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object specifies if the sideline loop-back is tuned on ,
+ user can change the loop back mode through the object.
+ normal,lineLoopback.
+ This object belongs to xfp.
+ "
+ ::={ rosMgmtOpticalTransceiverCurrentStatusEntry 9 }
+
+rosMgmtOpticalTransceiverUserXFILoopBack OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ normal(1),
+ xfiLoopback(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object specifies if the XFI loop-back is tuned on
+ user can change the loop back mode through the object.
+ normal,xfiLoopback.
+ This object belongs to xfp.
+ "
+ ::={ rosMgmtOpticalTransceiverCurrentStatusEntry 10 }
+
+rosMgmtOpticalTransceiverPortNotifyEnable OBJECT-TYPE
+ SYNTAX EnableVar
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object specifies the generation of a port notifications,
+ enable or disable.
+ This object belongs to xfp and sfp.
+ "
+ DEFVAL { enable}
+ ::={ rosMgmtOpticalTransceiverCurrentStatusEntry 11 }
+
+rosMgmtOpticalTransceiverPortDDMEnable OBJECT-TYPE
+ SYNTAX EnableVar
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object specifies the status of digitaldiagnotic on a port,
+ enable or disable.
+ This object belongs to xfp and sfp.
+ "
+ DEFVAL { enable}
+ ::={ rosMgmtOpticalTransceiverCurrentStatusEntry 12 }
+
+rosMgmtOpticalTransceiverPortCheckPwdEnable OBJECT-TYPE
+ SYNTAX EnableVar
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object specifies the status of password checking on a port,
+ enable or disable.
+ This object belongs to xfp.
+ "
+ DEFVAL { enable}
+ ::={ rosMgmtOpticalTransceiverCurrentStatusEntry 13 }
+
+ rosMgmtOpticalTransceiverTxFaultCount OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object specifies the number of tx-fault signals."
+ ::={ rosMgmtOpticalTransceiverCurrentStatusEntry 14 }
+
+ rosMgmtOpticalTransceiverTxFaultCountClear OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object specifies clear the statistcs of tx-fault signals."
+ ::={ rosMgmtOpticalTransceiverCurrentStatusEntry 15 }
+
+ rosMgmtOpticalTransceiverSpecificationCheckStatus OBJECT-TYPE
+ SYNTAX INTEGER{none(0),accord(1),notaccord(2)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object specifies the check status, accord(0)specifies
+ the optical module accord with industrial. not-accord(2)
+ specifies the optical module not accord with industrial."
+ ::={ rosMgmtOpticalTransceiverCurrentStatusEntry 16 }
+
+ rosMgmtOpticalTransceiverTxFaultStatus OBJECT-TYPE
+ SYNTAX INTEGER{normal(1),txfault(2)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object specifies the tx-fault status."
+ ::={ rosMgmtOpticalTransceiverCurrentStatusEntry 17 }
+
+ rosMgmtOpticalTransceiverPortCRCCheckEnable OBJECT-TYPE
+ SYNTAX EnableVar
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object specifies the status of CRC checking on a port, enable or disable.
+ This object belongs to sfp and xfp"
+ ::={ rosMgmtOpticalTransceiverCurrentStatusEntry 18 }
+
+ rosMgmtOpticalTransceiverBaseCRCCheckStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ none(0),
+ pass(1),
+ notpass(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object specifies the result of base information crc checking."
+ ::={ rosMgmtOpticalTransceiverCurrentStatusEntry 19 }
+
+ rosMgmtOpticalTransceiverStaticDdmCRCCheckStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ none(0),
+ pass(1),
+ notpass(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object specifies the result of static ddm crc checking."
+ ::={ rosMgmtOpticalTransceiverCurrentStatusEntry 20 }
+
+ rosMgmtOpticalTransceiverDynamicDdmCRCCheckStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ none(0),
+ pass(1),
+ notpass(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object specifies the result of Dynamic ddm crc checking."
+ ::={ rosMgmtOpticalTransceiverCurrentStatusEntry 21 }
+
+END
+
|