diff options
| author | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
|---|---|---|
| committer | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
| commit | 98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch) | |
| tree | 9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/ruckus/RUCKUS-ZD-SYSTEM-MIB | |
| download | mibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.tar.gz mibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.zip | |
Diffstat (limited to 'MIBS/ruckus/RUCKUS-ZD-SYSTEM-MIB')
| -rw-r--r-- | MIBS/ruckus/RUCKUS-ZD-SYSTEM-MIB | 1556 |
1 files changed, 1556 insertions, 0 deletions
diff --git a/MIBS/ruckus/RUCKUS-ZD-SYSTEM-MIB b/MIBS/ruckus/RUCKUS-ZD-SYSTEM-MIB new file mode 100644 index 0000000..19a73b8 --- /dev/null +++ b/MIBS/ruckus/RUCKUS-ZD-SYSTEM-MIB @@ -0,0 +1,1556 @@ +-- +-- Copyright 2010-2013 Ruckus Wireless, Inc. All rights reserved. +-- +-- RUCKUS WIRELESS, INC. CONFIDENTIAL - +-- This is an unpublished, proprietary work of Ruckus Wireless, Inc., and is +-- fully protected under copyright and trade secret laws. You may not view, +-- use, disclose, copy, or distribute this file or any information contained +-- herein except pursuant to a valid license from Ruckus. +-- + +RUCKUS-ZD-SYSTEM-MIB DEFINITIONS ::= BEGIN + +IMPORTS + ruckusZDSystemModule + FROM RUCKUS-ROOT-MIB + RuckusAdminStatus, + RuckusRadioMode, + RuckusSSID, + RuckusdB, + RuckusNameString, + RuckusCountryCode + FROM RUCKUS-TC-MIB + DisplayString, + MacAddress, + RowStatus, + TruthValue + FROM SNMPv2-TC + OBJECT-GROUP + FROM SNMPv2-CONF + ifIndex, + InterfaceIndex + FROM IF-MIB + MODULE-IDENTITY, + OBJECT-TYPE, + Counter32, + Integer32, + Unsigned32, + IpAddress + FROM SNMPv2-SMI; + +ruckusZDSystemMIB MODULE-IDENTITY + LAST-UPDATED "201010150800Z" + ORGANIZATION "Ruckus Wireless, Inc." + CONTACT-INFO + "Ruckus Wireless, Inc. + + Postal: + 350 West Java Dr. + Sunnyvale, CA 94089 + USA + + EMail: support@ruckuswireless.com + + Phone: +1-650-265-4200" + DESCRIPTION + "Ruckus ZD System mib" + ::= { ruckusZDSystemModule 1 } + +ruckusZDSystemObjects OBJECT IDENTIFIER ::= { ruckusZDSystemMIB 1 } + +ruckusZDSystemInfo OBJECT IDENTIFIER ::= { ruckusZDSystemObjects 1 } + +ruckusZDSystemName OBJECT-TYPE + SYNTAX DisplayString(SIZE(1..32)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "System name" + ::= { ruckusZDSystemInfo 1 } + +ruckusZDSystemIPAddr OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "IP Address" + ::= { ruckusZDSystemInfo 2 } + +ruckusZDSystemMacAddr OBJECT-TYPE + SYNTAX MacAddress + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "MAC Address" + ::= { ruckusZDSystemInfo 3 } + +ruckusZDSystemUptime OBJECT-TYPE + SYNTAX TimeTicks + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Up time" + ::= { ruckusZDSystemInfo 8 } + +ruckusZDSystemModel OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Model" + ::= { ruckusZDSystemInfo 9 } + +ruckusZDSystemLicensedAPs OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Licensed APs" + ::= { ruckusZDSystemInfo 12 } + +ruckusZDSystemMaxSta OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of max stations allowed." + ::= { ruckusZDSystemInfo 13 } + +ruckusZDSystemSerialNumber OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Serial number" + ::= { ruckusZDSystemInfo 15 } + +ruckusZDSystemVersion OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Software version" + ::= { ruckusZDSystemInfo 18 } + +ruckusZDSystemCountryCode OBJECT-TYPE + SYNTAX RuckusCountryCode + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Country code" + ::= { ruckusZDSystemInfo 20 } + +ruckusZDSystemAdminName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS write-only + STATUS current + DESCRIPTION + "Administrator account name." + ::= { ruckusZDSystemInfo 25 } + +ruckusZDSystemAdminPassword OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS write-only + STATUS current + DESCRIPTION + "Administrator account password." + ::= { ruckusZDSystemInfo 26 } + +ruckusZDSystemStatus OBJECT-TYPE + SYNTAX INTEGER { master(1), standby(2),noredundancy(3) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "current zd system status: + if enable smart redundancy, the status is master or standby, + if disable smart redundancy,the status is noredundancy" + DEFVAL { noredundancy } + ::= { ruckusZDSystemInfo 30 } + +ruckusZDSystemPeerConnectedStatus OBJECT-TYPE + SYNTAX INTEGER { connected(1), disconnected(2) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "peer zd connected status" + DEFVAL { disconnected } + ::= { ruckusZDSystemInfo 31 } + +ruckusZDSystemExpInfo OBJECT IDENTIFIER ::= { ruckusZDSystemObjects 5 } + +ruckusZDSystemNEId OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "NE Id." + ::= { ruckusZDSystemExpInfo 50 } + +ruckusZDSystemManufacturer OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Manufacturer." + ::= { ruckusZDSystemExpInfo 51 } + +ruckusZDSystemSoftwareName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Software name." + ::= { ruckusZDSystemExpInfo 52 } + +ruckusZDSystemCPUUtil OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "CPU utilization" + ::= { ruckusZDSystemExpInfo 58 } + +ruckusZDSystemMemoryUtil OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Memory utilization" + ::= { ruckusZDSystemExpInfo 59 } + +ruckusZDSystemMemorySize OBJECT-TYPE + SYNTAX Unsigned32 + UNITS + "MB" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Memory size" + ::= { ruckusZDSystemExpInfo 60 } + +ruckusZDSystemFlashFreeSize OBJECT-TYPE + SYNTAX Unsigned32 + UNITS + "KByte" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Flash free size" + ::= { ruckusZDSystemExpInfo 65 } + +ruckusZDSystemMgmtVlanID OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Management Vlan ID" + ::= { ruckusZDSystemExpInfo 67 } + +ruckusZDSystemCPUModel OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "CPU Model" + ::= { ruckusZDSystemExpInfo 70 } + +ruckusZDSystemtCPUSpeed OBJECT-TYPE + SYNTAX Unsigned32 + UNITS + "BogoMIPS" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "CPU Speed" + ::= { ruckusZDSystemExpInfo 71 } + +ruckusZDSystemtFlashModel OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Flash Model" + ::= { ruckusZDSystemExpInfo 72 } + +ruckusZDSystemtMemModel OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Memory Model" + ::= { ruckusZDSystemExpInfo 73 } + +ruckusZDSystemStartTime OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "System Startup Time" + ::= { ruckusZDSystemExpInfo 74 } + +ruckusZDSystemCurrentTime OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "System current time." + ::= { ruckusZDSystemExpInfo 80 } + +ruckusZDSystemAPFirmwareServer OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "AP firmware download server." + ::= { ruckusZDSystemExpInfo 81 } + +ruckusZDSystemAPConfigServer OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "AP configuration server." + ::= { ruckusZDSystemExpInfo 82 } + +ruckusZDSystemIDSAllowedESSID OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "List of allowed ESSID, separated by semiclon." + ::= { ruckusZDSystemExpInfo 85 } + +ruckusZDSystemIDSAllowBSSID OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "List of allowed BSSID, separated by semicolon." + ::= { ruckusZDSystemExpInfo 86 } + +ruckusZDSystemIDSAllowOUI OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "List of allowed OUI, separated by semicolon." + ::= { ruckusZDSystemExpInfo 87 } + +ruckusZDSystemBandwidthUtilValve OBJECT-TYPE + SYNTAX Unsigned32 (1..100) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Number of system bandwidth utilization percent." + ::= { ruckusZDSystemExpInfo 90 } + +ruckusZDSystemDropPacketRateValve OBJECT-TYPE + SYNTAX Unsigned32 (1..100) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Number of system drop packets rate percent." + ::= { ruckusZDSystemExpInfo 91 } + +ruckusZDSystemCPUUtilValve OBJECT-TYPE + SYNTAX Unsigned32 (1..100) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Number of system CPU utilization percent." + ::= { ruckusZDSystemExpInfo 92 } + +ruckusZDSystemMemUtilValve OBJECT-TYPE + SYNTAX Unsigned32 (1..100) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Number of system memory utilization percent." + ::= { ruckusZDSystemExpInfo 95 } + +ruckusZDSystemOnlineStaValve OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Number of system online STA." + ::= { ruckusZDSystemExpInfo 96 } + +ruckusZDSystemACLocationLongitude OBJECT-TYPE + SYNTAX DisplayString(SIZE(1..32)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "AC longitude." + ::= { ruckusZDSystemExpInfo 97 } + +ruckusZDSystemACLocationLatitude OBJECT-TYPE + SYNTAX DisplayString(SIZE(1..32)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "AC latitude." + ::= { ruckusZDSystemExpInfo 98 } + +ruckusZDSystemDHCPServer OBJECT-TYPE + SYNTAX INTEGER { enable(1), disable(2) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "System DHCP server enable or disable" + ::= { ruckusZDSystemExpInfo 110 } + +ruckusZDAPCPUvalve OBJECT-TYPE + SYNTAX Unsigned32 (0..100) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "AP's CPU utilization valve for sending trap" + ::= { ruckusZDSystemExpInfo 120 } + +ruckusZDAPMemoryvalve OBJECT-TYPE + SYNTAX Unsigned32 (0..100) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "AP'S Memory utilization valve for sending trap" + ::= { ruckusZDSystemExpInfo 121 } + +ruckusZDHeartBeatStatus OBJECT-TYPE + SYNTAX TruthValue { off(0), on(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Current heartbeat on-off status." + ::= { ruckusZDSystemExpInfo 122 } + +ruckusZDHeartBeatPeriod OBJECT-TYPE + SYNTAX Unsigned32 (1..10000) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Heartbeat interval between ZD and NMS(unit:second)." + ::= { ruckusZDSystemExpInfo 123 } + +ruckusZDSystemIPTable OBJECT-TYPE + SYNTAX SEQUENCE OF RuckusZDSystemIPEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "ZD System IP table." + ::= { ruckusZDSystemObjects 8 } + +ruckusZDSystemIPEntry OBJECT-TYPE + SYNTAX RuckusZDSystemIPEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Specifies IP configuration entry. ifIndex always be 1" + INDEX { + ruckusZDSystemIPIndex } + ::= { ruckusZDSystemIPTable 1 } + +RuckusZDSystemIPEntry ::= SEQUENCE { + ruckusZDSystemIPIndex Unsigned32, + ruckusZDSystemIPVersion INTEGER, + ruckusZDSystemIPAddrMode INTEGER, + ruckusZDSystemIPAddress IpAddress, + ruckusZDSystemIPAddrNetmask IpAddress, + ruckusZDSystemIPGateway IpAddress, + ruckusZDSystemIPPrimaryDNS IpAddress, + ruckusZDSystemIPSecondaryDNS IpAddress, + ruckusZDSystemIPV6AddressModel INTEGER, + ruckusZDSystemIPV6Address OCTET STRING, + ruckusZDSystemIPV6PrefixLen INTEGER, + ruckusZDSystemIPV6Gateway OCTET STRING, + ruckusZDSystemIPV6PrimaryDNS OCTET STRING, + ruckusZDSystemIPV6SecondaryDNS OCTET STRING +} + +ruckusZDSystemIPIndex OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Interface index." + ::= { ruckusZDSystemIPEntry 1 } + +ruckusZDSystemIPVersion OBJECT-TYPE + SYNTAX INTEGER { ipv4(1), ipv6(2),dualstack(3) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "current ip version " + ::= { ruckusZDSystemIPEntry 2 } + +ruckusZDSystemIPAddrMode OBJECT-TYPE + SYNTAX INTEGER { static(1), dhcp(2) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "IP address mode, static ip or by dhcp." + ::= { ruckusZDSystemIPEntry 5 } + +ruckusZDSystemIPAddress OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "IP address." + ::= { ruckusZDSystemIPEntry 6 } + +ruckusZDSystemIPAddrNetmask OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "IP address netmask." + ::= { ruckusZDSystemIPEntry 8 } + +ruckusZDSystemIPGateway OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Gateway IP address." + ::= { ruckusZDSystemIPEntry 10 } + +ruckusZDSystemIPPrimaryDNS OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Primary DNS IP address." + ::= { ruckusZDSystemIPEntry 12 } + +ruckusZDSystemIPSecondaryDNS OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Secondary DNS IP address." + ::= { ruckusZDSystemIPEntry 13 } + +ruckusZDSystemIPV6AddressModel OBJECT-TYPE + SYNTAX INTEGER { auto-configuration(1), + static(2) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "current ipv6 address model " + ::= { ruckusZDSystemIPEntry 20 } + +ruckusZDSystemIPV6Address OBJECT-TYPE + SYNTAX OCTET STRING (SIZE (2..40)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "IPV6 Address" + ::= { ruckusZDSystemIPEntry 21 } + +ruckusZDSystemIPV6PrefixLen OBJECT-TYPE + SYNTAX INTEGER (3..128) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Specifies the ip v6 address prefix length if the ruckusZDSystemIPV6AddrModel + is set to static(2)." + ::= { ruckusZDSystemIPEntry 22 } + +ruckusZDSystemIPV6Gateway OBJECT-TYPE + SYNTAX OCTET STRING (SIZE (2..40)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Specifies the gateway ipv6 address if the ruckusZDSystemIPV6AddrModel + is set to static(2)." + ::= { ruckusZDSystemIPEntry 25 } + +ruckusZDSystemIPV6PrimaryDNS OBJECT-TYPE + SYNTAX OCTET STRING (SIZE (2..40)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Specifies primary DNS IPV6 address." + ::= { ruckusZDSystemIPEntry 28 } + + +ruckusZDSystemIPV6SecondaryDNS OBJECT-TYPE + SYNTAX OCTET STRING (SIZE (2..40)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Specifies secondary DNS IPV6 address." + ::= { ruckusZDSystemIPEntry 29 } + + +ruckusZDSystemServices OBJECT IDENTIFIER ::= { ruckusZDSystemObjects 12 } + +ruckusZDSystemNTP OBJECT IDENTIFIER ::= { ruckusZDSystemServices 3 } + +ruckusZDSystemTimeWithNTP OBJECT-TYPE + SYNTAX INTEGER { enable(1), disable(2) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable the Zone Director system to synchronize its system time with NTP." + DEFVAL { disable } + ::= { ruckusZDSystemNTP 1 } + +ruckusZDSystemTimeNTPServer OBJECT-TYPE + SYNTAX OCTET STRING (SIZE (1..128)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The NTP Server (URL) the Zone Director system to synchronize it system time with." + ::= { ruckusZDSystemNTP 2 } + +ruckusZDSystemSMTP OBJECT IDENTIFIER ::= { ruckusZDSystemServices 5 } + +ruckusZDSystemEmailTriggerEnable OBJECT-TYPE + SYNTAX INTEGER { enable(1), disable(2) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Send an email message when an alarm is triggered for the Zone Director system. + Make sure the ruckusZDSystemEmailAddress and ruckusZDSystemSMTPServerPort are not empty before enable it." + DEFVAL { disable } + ::= { ruckusZDSystemSMTP 1 } + +ruckusZDSystemEmailAddress OBJECT-TYPE + SYNTAX DisplayString (SIZE (1..64)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The Email Address receive the alarm message from the Zone Director system." + ::= { ruckusZDSystemSMTP 2 } + +ruckusZDSystemSMTPServerName OBJECT-TYPE + SYNTAX DisplayString (SIZE (1..128)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The SMTP Server Name." + ::= { ruckusZDSystemSMTP 3 } + +ruckusZDSystemSMTPServerPort OBJECT-TYPE + SYNTAX INTEGER (1..65535) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The SMTP Server Port." + DEFVAL { 25 } + ::= { ruckusZDSystemSMTP 4 } + +ruckusZDSystemSMTPAuthUsername OBJECT-TYPE + SYNTAX DisplayString (SIZE (1..128)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "SMTP Authentication Username." + ::= { ruckusZDSystemSMTP 5 } + +ruckusZDSystemSMTPAuthPassword OBJECT-TYPE + SYNTAX DisplayString (SIZE (1..128)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "MTP Authentication Password." + ::= { ruckusZDSystemSMTP 6 } + +ruckusZDSystemFromEmailAddress OBJECT-TYPE + SYNTAX DisplayString (SIZE (1..128)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The From Email Address ." + ::= { ruckusZDSystemSMTP 7 } + +ruckusZDSystemSMTPEncryptionOptions OBJECT-TYPE + SYNTAX INTEGER { none(1), tls(2), starttls(3) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "SMTP Encryption Options ." + DEFVAL { none } + ::= { ruckusZDSystemSMTP 8 } + +ruckusZDSystemSyslog OBJECT IDENTIFIER ::= { ruckusZDSystemServices 8 } + +ruckusZDSystemLogWithSysLog OBJECT-TYPE + SYNTAX INTEGER { enable(1), disable(2) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable the Zone Director system to log its system events with sysLog facility." + DEFVAL { disable } + ::= { ruckusZDSystemSyslog 1 } + +ruckusZDSystemSysLogServer OBJECT-TYPE + SYNTAX OCTET STRING (SIZE (2..40)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The sysLog Server IP or IPV6 address ,the Zone Director system reports its' system events to it." + ::= { ruckusZDSystemSyslog 2 } + +ruckusZDSystemFlexMaster OBJECT IDENTIFIER ::= { ruckusZDSystemServices 9 } + +ruckusZDSystemFlexMasterEnable OBJECT-TYPE + SYNTAX INTEGER { enable(1), disable(2) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable FlexMaster Network Management for the Zone Director system." + DEFVAL { disable } + ::= { ruckusZDSystemFlexMaster 1 } + +ruckusZDSystemFlexMasterServer OBJECT-TYPE + SYNTAX DisplayString (SIZE(1..128)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The FlexMaster Server URL to connect the Zone Director system ." + ::= { ruckusZDSystemFlexMaster 2 } + +ruckusZDSystemFlexMasterInterval OBJECT-TYPE + SYNTAX INTEGER (1..60) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The FlexMaster Interval to connect the Zone Director (Minutes)." + DEFVAL { 10 } + ::= { ruckusZDSystemFlexMaster 3 } + +ruckusZDSystemStpInfo OBJECT IDENTIFIER ::= { ruckusZDSystemServices 12 } + +ruckusZDSystemStpStatus OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable/disable spanning tree." + ::= { ruckusZDSystemStpInfo 1 } + +ruckusZDSystemSNMP OBJECT IDENTIFIER ::= { ruckusZDSystemServices 15 } + +ruckusZDSystemSNMPTrapInfo OBJECT IDENTIFIER ::= { ruckusZDSystemSNMP 3 } + +ruckusZDSystemSNMPTrapEnable OBJECT-TYPE + SYNTAX INTEGER { enable(1), disable(2) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable the SNMP Trap facility for the Zone Director system." + DEFVAL { disable } + ::= { ruckusZDSystemSNMPTrapInfo 1 } + +ruckusZDSystemSNMPTrapVersion OBJECT-TYPE + SYNTAX INTEGER { snmpv2(1), snmpv3(2) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Config the SNMP Trap version for the Zone Director system." + DEFVAL { snmpv2 } + ::= { ruckusZDSystemSNMPTrapInfo 2 } + +ruckusZDSystemSNMPV2TrapSvrTable OBJECT-TYPE + SYNTAX SEQUENCE OF RuckusZDSystemSNMPV2TrapSvrEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "ZD SNMPV2 trap server table." + ::= { ruckusZDSystemSNMPTrapInfo 35 } + +ruckusZDSystemSNMPV2TrapSvrEntry OBJECT-TYPE + SYNTAX RuckusZDSystemSNMPV2TrapSvrEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Specifies SNMPV2 Trap server configuration entry.index be 1-4." + INDEX { + ruckusZDSystemSNMPV2TrapSvrIndex } + ::= { ruckusZDSystemSNMPV2TrapSvrTable 1 } + +RuckusZDSystemSNMPV2TrapSvrEntry ::= SEQUENCE { + ruckusZDSystemSNMPV2TrapSvrIndex INTEGER, + ruckusZDSystemSNMPV2TrapServer OCTET STRING, + ruckusZDSystemSNMPV2TrapSvrRowStatus RowStatus +} + +ruckusZDSystemSNMPV2TrapSvrIndex OBJECT-TYPE + SYNTAX INTEGER (1..4) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Config the SNMPV2 Trap server index." + ::= { ruckusZDSystemSNMPV2TrapSvrEntry 1 } + +ruckusZDSystemSNMPV2TrapServer OBJECT-TYPE + SYNTAX OCTET STRING (SIZE (2..40)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The SNMP V2 Trap Server4 IP (V4 or V6) address for the Zone Director system." + ::= { ruckusZDSystemSNMPV2TrapSvrEntry 3 } + +ruckusZDSystemSNMPV2TrapSvrRowStatus OBJECT-TYPE + SYNTAX RowStatus + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Create, Delete snmp V2 trap server table. + 1,ACTIVE state,only for read; + 4,CREATEANDGO, create a new table; + 6,DESTROY, delete a existing table." + ::= { ruckusZDSystemSNMPV2TrapSvrEntry 8 } + +ruckusZDSystemSNMPV3TrapSvrTable OBJECT-TYPE + SYNTAX SEQUENCE OF RuckusZDSystemSNMPV3TrapSvrEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "ZD SNMPV3 trap server table." + ::= { ruckusZDSystemSNMPTrapInfo 36 } + +ruckusZDSystemSNMPV3TrapSvrEntry OBJECT-TYPE + SYNTAX RuckusZDSystemSNMPV3TrapSvrEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Specifies SNMPV3 Trap server configuration entry.index be 1-4." + INDEX { + ruckusZDSystemSNMPV3TrapSvrIndex } + ::= { ruckusZDSystemSNMPV3TrapSvrTable 1 } + +RuckusZDSystemSNMPV3TrapSvrEntry ::= SEQUENCE { + ruckusZDSystemSNMPV3TrapSvrIndex INTEGER, + ruckusZDSystemSNMPV3TrapServer OCTET STRING, + ruckusZDSystemSNMPV3TrapUser DisplayString, + ruckusZDSystemSNMPV3TrapAuth INTEGER, + ruckusZDSystemSNMPV3TrapAuthKey DisplayString, + ruckusZDSystemSNMPV3TrapPrivacy INTEGER, + ruckusZDSystemSNMPV3TrapPrivacyKey DisplayString, + ruckusZDSystemSNMPV3TrapSvrRowStatus RowStatus +} + +ruckusZDSystemSNMPV3TrapSvrIndex OBJECT-TYPE + SYNTAX INTEGER (1..4) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Config the SNMPV3 Trap server index." + ::= { ruckusZDSystemSNMPV3TrapSvrEntry 1 } + +ruckusZDSystemSNMPV3TrapServer OBJECT-TYPE + SYNTAX OCTET STRING (SIZE (2..40)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The SNMP V2 Trap Server4 IP (V4 or V6) address for the Zone Director system." + ::= { ruckusZDSystemSNMPV3TrapSvrEntry 5 } + +ruckusZDSystemSNMPV3TrapUser OBJECT-TYPE + SYNTAX DisplayString (SIZE(1..32)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The SNMP V3 Trap Username ." + ::= { ruckusZDSystemSNMPV3TrapSvrEntry 8 } + +ruckusZDSystemSNMPV3TrapAuth OBJECT-TYPE + SYNTAX INTEGER { md5(1), sha(2) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Config the SNMP V3 Trap Authentication type." + DEFVAL { md5 } + ::= { ruckusZDSystemSNMPV3TrapSvrEntry 10 } + +ruckusZDSystemSNMPV3TrapAuthKey OBJECT-TYPE + SYNTAX DisplayString (SIZE(8..32)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The SNMP V3 Trap Authentication Pass Phrase .the read value is ********." + ::= { ruckusZDSystemSNMPV3TrapSvrEntry 11 } + +ruckusZDSystemSNMPV3TrapPrivacy OBJECT-TYPE + SYNTAX INTEGER { des(1), aes(2), none(3) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Config the SNMP V3 Trap Privacy type." + DEFVAL { des } + ::= { ruckusZDSystemSNMPV3TrapSvrEntry 15 } + +ruckusZDSystemSNMPV3TrapPrivacyKey OBJECT-TYPE + SYNTAX DisplayString (SIZE(8..32)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The SNMP V3 Trap Privacy Phrase .the read value is ********." + ::= { ruckusZDSystemSNMPV3TrapSvrEntry 16 } + +ruckusZDSystemSNMPV3TrapSvrRowStatus OBJECT-TYPE + SYNTAX RowStatus + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Create, Delete snmp trap server table. + 1,ACTIVE state,only for read; + 4,CREATEANDGO, create a new table; + 6,DESTROY, delete a existing table." + ::= { ruckusZDSystemSNMPV3TrapSvrEntry 20 } + + +ruckusZDSystemSNMPV2Table OBJECT-TYPE + SYNTAX SEQUENCE OF RuckusZDSystemSNMPV2Entry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "ZD SNMPV2 table." + ::= { ruckusZDSystemSNMP 5 } + +ruckusZDSystemSNMPV2Entry OBJECT-TYPE + SYNTAX RuckusZDSystemSNMPV2Entry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Specifies SNMP V2 configuration entry.ifIndex always be 1." + INDEX { + ifIndex } + ::= { ruckusZDSystemSNMPV2Table 1 } + +RuckusZDSystemSNMPV2Entry ::= SEQUENCE { + ruckusZDSystemSNMPEnable INTEGER, + ruckusZDSystemSNMPROCommunity DisplayString, + ruckusZDSystemSNMPRWCommunity DisplayString, + ruckusZDSystemSNMPSysContact DisplayString, + ruckusZDSystemSNMPSysLocation DisplayString +} + +ruckusZDSystemSNMPEnable OBJECT-TYPE + SYNTAX INTEGER { enable(1), disable(2) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable/disable SNMP." + ::= { ruckusZDSystemSNMPV2Entry 2 } + +ruckusZDSystemSNMPROCommunity OBJECT-TYPE + SYNTAX DisplayString (SIZE(1..32)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "SNMP read-only community.the read value is ********." + ::= { ruckusZDSystemSNMPV2Entry 5 } + +ruckusZDSystemSNMPRWCommunity OBJECT-TYPE + SYNTAX DisplayString (SIZE(1..32)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "SNMP read-write community.the read value is ********." + ::= { ruckusZDSystemSNMPV2Entry 6 } + +ruckusZDSystemSNMPSysContact OBJECT-TYPE + SYNTAX DisplayString (SIZE(1..64)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "SNMP read-write community." + ::= { ruckusZDSystemSNMPV2Entry 7 } + +ruckusZDSystemSNMPSysLocation OBJECT-TYPE + SYNTAX DisplayString (SIZE(1..64)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "SNMP read-write community." + ::= { ruckusZDSystemSNMPV2Entry 8 } + +ruckusZDSystemSNMPV3Table OBJECT-TYPE + SYNTAX SEQUENCE OF RuckusZDSystemSNMPV3Entry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "ZD SNMPV3 table." + ::= { ruckusZDSystemSNMP 8 } + +ruckusZDSystemSNMPV3Entry OBJECT-TYPE + SYNTAX RuckusZDSystemSNMPV3Entry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Specifies SNMP V3 configuration entry.ifIndex always be 1" + INDEX { + ifIndex } + ::= { ruckusZDSystemSNMPV3Table 1 } + +RuckusZDSystemSNMPV3Entry ::= SEQUENCE { + ruckusZDSystemSNMPV3Enable INTEGER, + ruckusZDSystemSNMPV3RoUser DisplayString, + ruckusZDSystemSNMPV3RoAuth INTEGER, + ruckusZDSystemSNMPV3RoAuthKey DisplayString, + ruckusZDSystemSNMPV3RoPrivacy INTEGER, + ruckusZDSystemSNMPV3RoPrivacyKey DisplayString, + ruckusZDSystemSNMPV3RwUser DisplayString, + ruckusZDSystemSNMPV3RwAuth INTEGER, + ruckusZDSystemSNMPV3RwAuthKey DisplayString, + ruckusZDSystemSNMPV3RwPrivacy INTEGER, + ruckusZDSystemSNMPV3RwPrivacyKey DisplayString +} + +ruckusZDSystemSNMPV3Enable OBJECT-TYPE + SYNTAX INTEGER { enable(1), disable(2) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable/disable SNMPV3." + ::= { ruckusZDSystemSNMPV3Entry 2 } + +ruckusZDSystemSNMPV3RoUser OBJECT-TYPE + SYNTAX DisplayString (SIZE(1..31)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The SNMP V3 Ro Username ." + ::= { ruckusZDSystemSNMPV3Entry 5 } + +ruckusZDSystemSNMPV3RoAuth OBJECT-TYPE + SYNTAX INTEGER { md5(1), sha(2) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Config the SNMP V3 Ro Authentication type." + DEFVAL { md5 } + ::= { ruckusZDSystemSNMPV3Entry 6 } + +ruckusZDSystemSNMPV3RoAuthKey OBJECT-TYPE + SYNTAX DisplayString (SIZE(8..32)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The SNMP V3 Ro Authentication Pass Phrase .the read value is ********." + ::= { ruckusZDSystemSNMPV3Entry 7 } + +ruckusZDSystemSNMPV3RoPrivacy OBJECT-TYPE + SYNTAX INTEGER { des(1), aes(2), none(3) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Config the SNMP V3 Ro Privacy type." + DEFVAL { des } + ::= { ruckusZDSystemSNMPV3Entry 8 } + +ruckusZDSystemSNMPV3RoPrivacyKey OBJECT-TYPE + SYNTAX DisplayString (SIZE(8..32)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The SNMP V3 Ro Privacy Phrase .the read value is ********." + ::= { ruckusZDSystemSNMPV3Entry 9 } + +ruckusZDSystemSNMPV3RwUser OBJECT-TYPE + SYNTAX DisplayString (SIZE(1..31)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The SNMP V3 Rw Username ." + ::= { ruckusZDSystemSNMPV3Entry 12 } + +ruckusZDSystemSNMPV3RwAuth OBJECT-TYPE + SYNTAX INTEGER { md5(1), sha(2) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Config the SNMP V3 Ro Authentication type." + DEFVAL { md5 } + ::= { ruckusZDSystemSNMPV3Entry 13 } + +ruckusZDSystemSNMPV3RwAuthKey OBJECT-TYPE + SYNTAX DisplayString (SIZE(8..32)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The SNMP V3 Rw Authentication Pass Phrase .the read value is ********." + ::= { ruckusZDSystemSNMPV3Entry 14 } + +ruckusZDSystemSNMPV3RwPrivacy OBJECT-TYPE + SYNTAX INTEGER { des(1), aes(2), none(3) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Config the SNMP V3 Rw Privacy type." + DEFVAL { des } + ::= { ruckusZDSystemSNMPV3Entry 15 } + +ruckusZDSystemSNMPV3RwPrivacyKey OBJECT-TYPE + SYNTAX DisplayString (SIZE(8..32)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The SNMP V3 Rw Privacy Phrase .the read value is ********." + ::= { ruckusZDSystemSNMPV3Entry 16 } + +ruckusZDSystemLoadBalanceInfo OBJECT IDENTIFIER ::= { ruckusZDSystemServices 20 } + +ruckusZDSystemLoadBalance24GStatus OBJECT-TYPE + SYNTAX TruthValue {false(0), true(1)} + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable/disable load balance on 2.4G radio." + ::= { ruckusZDSystemLoadBalanceInfo 1 } + +ruckusZDSystemLoadBalance5GStatus OBJECT-TYPE + SYNTAX TruthValue {false(0), true(1)} + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable/disable load balance on 5G radio." + ::= { ruckusZDSystemLoadBalanceInfo 2 } + +ruckusZDSystemLoadBalanceAdjacent24GThreshold OBJECT-TYPE + SYNTAX INTEGER (1..100) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Adjacent 2.4G radio threshold(dB)." + ::= { ruckusZDSystemLoadBalanceInfo 3 } + +ruckusZDSystemLoadBalanceAdjacent5GThreshold OBJECT-TYPE + SYNTAX INTEGER (1..100) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Adjacent 5G radio threshold(dB)." + ::= { ruckusZDSystemLoadBalanceInfo 4 } + +ruckusZDSystemLoadBalanceTrafficDifference OBJECT-TYPE + SYNTAX Unsigned32 + UNITS + "Kbps" + MAX-ACCESS read-write + STATUS deprecated + DESCRIPTION + "This node had been deprecated from 9.9; Load balance traffic difference." + ::= { ruckusZDSystemLoadBalanceInfo 5 } + +ruckusZDSystemLoadBalanceType OBJECT-TYPE + SYNTAX INTEGER { user(1), traffic(2) } + MAX-ACCESS read-write + STATUS deprecated + DESCRIPTION + "This node had been deprecated from 9.9; Load balance type." + ::= { ruckusZDSystemLoadBalanceInfo 6 } + +-- +-- End, Zone Director System Configuration +-- + +-- +-- Zone Director System Statistics, Operation Status +-- +ruckusZDSystemStats OBJECT IDENTIFIER ::= { ruckusZDSystemObjects 15 } + +ruckusZDSystemStatsNumAP OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of AP" + ::= { ruckusZDSystemStats 1 } + +ruckusZDSystemStatsNumSta OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of authorized client devices" + ::= { ruckusZDSystemStats 2 } + +ruckusZDSystemStatsNumRogue OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of rogue devices" + ::= { ruckusZDSystemStats 3 } + +ruckusZDSystemStatsNumRogueKnown OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of known rogue devices" + ::= { ruckusZDSystemStats 4 } + +ruckusZDSystemStatsWLANTotalRxPkts OBJECT-TYPE + SYNTAX Counter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Total received packets of wireless interfaces" + ::= { ruckusZDSystemStats 5 } + +ruckusZDSystemStatsWLANTotalRxBytes OBJECT-TYPE + SYNTAX Counter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Total received bytes of wireless interfaces" + ::= { ruckusZDSystemStats 6 } + +ruckusZDSystemStatsWLANTotalRxMulticast OBJECT-TYPE + SYNTAX Counter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Total received multicast packets of wireless interfaces" + ::= { ruckusZDSystemStats 7 } + +ruckusZDSystemStatsWLANTotalTxPkts OBJECT-TYPE + SYNTAX Counter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Total transmitted packets of wireless interfaces" + ::= { ruckusZDSystemStats 8 } + +ruckusZDSystemStatsWLANTotalTxBytes OBJECT-TYPE + SYNTAX Counter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Total transmitted bytes of wireless interfaces" + ::= { ruckusZDSystemStats 9 } + +ruckusZDSystemStatsWLANTotalTxMulticast OBJECT-TYPE + SYNTAX Counter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Total transmitted multicast packets of wireless interfaces" + ::= { ruckusZDSystemStats 10 } + +ruckusZDSystemStatsWLANTotalTxFail OBJECT-TYPE + SYNTAX Counter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Total transmitted fail packets of wireless interfaces" + ::= { ruckusZDSystemStats 11 } + +ruckusZDSystemStatsWLANTotalTxRetry OBJECT-TYPE + SYNTAX Counter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Total transmitted retry packets of wireless interfaces" + ::= { ruckusZDSystemStats 12 } + +ruckusZDSystemStatsCPUUtil OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "CPU utilization" + ::= { ruckusZDSystemStats 13 } + +ruckusZDSystemStatsMemoryUtil OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Memory utilization" + ::= { ruckusZDSystemStats 14 } + +ruckusZDSystemStatsNumRegisteredAP OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Number of registered AP" + ::= { ruckusZDSystemStats 15 } + +ruckusZDSystemStatsWLANTotalAssocFail OBJECT-TYPE + SYNTAX Counter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Total number of failed station associations." + ::= { ruckusZDSystemStats 16 } + +ruckusZDSystemStatsWLANTotalRxErrFrm OBJECT-TYPE + SYNTAX Counter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Total number of errornous downlink frames." + ::= { ruckusZDSystemStats 17 } + +ruckusZDSystemStatsWLANTotalTxDroppedPkt OBJECT-TYPE + SYNTAX Counter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Total number of dropped downlink packets." + ::= { ruckusZDSystemStats 19 } + +ruckusZDSystemStatsWLANTotalTxErrFrm OBJECT-TYPE + SYNTAX Counter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Total number of errornous downlink frames." + ::= { ruckusZDSystemStats 20 } + +ruckusZDSystemStatsWLANTotalTxDroppedFrm OBJECT-TYPE + SYNTAX Counter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Total number of dropped downlink frames." + ::= { ruckusZDSystemStats 21 } + +ruckusZDSystemStatsLanTxRate OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Lan transmit rate kbyte/s in last 5 minutes ." + ::= { ruckusZDSystemStats 23 } + +ruckusZDSystemStatsLanRxRate OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Lan received rate kbyte/s in last 5 minutes ." + ::= { ruckusZDSystemStats 24 } + +ruckusZDSystemStatsAllNumSta OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of All client devices" + ::= { ruckusZDSystemStats 30 } + +ruckusZDEthInfo OBJECT IDENTIFIER ::= { ruckusZDSystemObjects 18 } + +ruckusZDEthNum OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of ethernet devices." + ::= { ruckusZDEthInfo 1 } + +ruckusZDEthTable OBJECT-TYPE + SYNTAX SEQUENCE OF RuckusZDEthEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "ZD Ethernet device table." + ::= { ruckusZDEthInfo 2 } + +ruckusZDEthEntry OBJECT-TYPE + SYNTAX RuckusZDEthEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Specifies each ZD Ethernet device entry." + INDEX { + ruckusZDEthIfIndex } + ::= { ruckusZDEthTable 1 } + +RuckusZDEthEntry ::= SEQUENCE { + ruckusZDEthIfIndex Unsigned32, + ruckusZDEthName DisplayString, + ruckusZDEthDesc DisplayString, + ruckusZDEthType INTEGER, + ruckusZDEthStatus INTEGER, + ruckusZDEthPhysAddr MacAddress, + ruckusZDEthMtu Unsigned32, + ruckusZDEthIfSpeed Unsigned32, + ruckusZDEthUtil INTEGER, + ruckusZDEthTxBcastPkts Counter32, + ruckusZDEthTxMcastPkts Counter32, + ruckusZDEthRxBcastPkts Counter32, + ruckusZDEthRxMcastPkts Counter32, + ruckusZDEthTxUniPkts Counter32, + ruckusZDEthRxUniPkts Counter32, + ruckusZDEthTxPkts Counter32, + ruckusZDEthRxPkts Counter32, + ruckusZDEthDropTxPkts Counter32, + ruckusZDEthDropRxPkts Counter32, + ruckusZDEthTxBytes Counter32, + ruckusZDEthRxBytes Counter32 +} + +ruckusZDEthIfIndex OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Ethernet device interface index." + ::= { ruckusZDEthEntry 1 } + +ruckusZDEthName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Ethernet device name." + ::= { ruckusZDEthEntry 2 } + +ruckusZDEthDesc OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Ethernet device description." + ::= { ruckusZDEthEntry 3 } + +ruckusZDEthType OBJECT-TYPE + SYNTAX INTEGER { other(1), ethernet-csmacd(2) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Ethernet device type." + ::= { ruckusZDEthEntry 4 } + +ruckusZDEthStatus OBJECT-TYPE + SYNTAX INTEGER { up(1), down(2) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Ethernet device status." + ::= { ruckusZDEthEntry 5 } + +ruckusZDEthPhysAddr OBJECT-TYPE + SYNTAX MacAddress + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Ethernet device MAC address." + ::= { ruckusZDEthEntry 6 } + +ruckusZDEthMtu OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Ethernet device mtu size." + ::= { ruckusZDEthEntry 7 } + +ruckusZDEthIfSpeed OBJECT-TYPE + SYNTAX Unsigned32 + UNITS + "Mbps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Ethernet device interface speed." + ::= { ruckusZDEthEntry 8 } + +ruckusZDEthUtil OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Ethernet device utilization." + ::= { ruckusZDEthEntry 9 } + +ruckusZDEthTxBcastPkts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Ethernet device transmitted broadcast packets number ." + ::= { ruckusZDEthEntry 10 } + +ruckusZDEthTxMcastPkts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Ethernet device transmitted multicast packets number ." + ::= { ruckusZDEthEntry 11 } + +ruckusZDEthRxBcastPkts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Ethernet device received broadcast packets number ." + ::= { ruckusZDEthEntry 12 } + +ruckusZDEthRxMcastPkts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Ethernet device received mutilcast packets number ." + ::= { ruckusZDEthEntry 13 } + +ruckusZDEthTxUniPkts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Ethernet device transmitted unicast packets number ." + ::= { ruckusZDEthEntry 14 } + +ruckusZDEthRxUniPkts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Ethernet device received unicast packets number ." + ::= { ruckusZDEthEntry 15 } + +ruckusZDEthTxPkts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Ethernet device transmitted packets number ." + ::= { ruckusZDEthEntry 16 } + +ruckusZDEthRxPkts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Ethernet device received packets number ." + ::= { ruckusZDEthEntry 17 } + +ruckusZDEthDropTxPkts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Ethernet device transmitted drop packets number ." + ::= { ruckusZDEthEntry 18 } + +ruckusZDEthDropRxPkts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Ethernet device received drop packets number ." + ::= { ruckusZDEthEntry 19 } + +ruckusZDEthTxBytes OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Ethernet device transmitted bytes number ." + ::= { ruckusZDEthEntry 20 } + +ruckusZDEthRxBytes OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Ethernet device received bytes number ." + ::= { ruckusZDEthEntry 21 } + +END |