summaryrefslogtreecommitdiff
path: root/MIBS/saf/SAF-INTEGRAX-MIB
diff options
context:
space:
mode:
authorDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
committerDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
commit98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch)
tree9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/saf/SAF-INTEGRAX-MIB
downloadmibs-main.tar.gz
mibs-main.zip
Initial commitHEADmain
Diffstat (limited to 'MIBS/saf/SAF-INTEGRAX-MIB')
-rw-r--r--MIBS/saf/SAF-INTEGRAX-MIB2857
1 files changed, 2857 insertions, 0 deletions
diff --git a/MIBS/saf/SAF-INTEGRAX-MIB b/MIBS/saf/SAF-INTEGRAX-MIB
new file mode 100644
index 0000000..a43c197
--- /dev/null
+++ b/MIBS/saf/SAF-INTEGRAX-MIB
@@ -0,0 +1,2857 @@
+SAF-INTEGRAX-MIB DEFINITIONS ::= BEGIN
+
+-- Definitions for include by other SAF Tehnika mib modules
+
+IMPORTS
+ MODULE-IDENTITY, OBJECT-TYPE, Integer32, Gauge32, Counter64,
+ TimeTicks
+ FROM SNMPv2-SMI -- [RFC2578]
+ pointToPoint
+ FROM SAF-ENTERPRISE
+ DateAndTime, TEXTUAL-CONVENTION
+ FROM SNMPv2-TC
+ DisplayString, PhysAddress
+ FROM RFC1213-MIB
+ safIntegra
+ FROM SAF-INTEGRA-MIB
+ OBJECT-GROUP, MODULE-COMPLIANCE
+ FROM SNMPv2-CONF -- [RFC2580]
+ IpAddress
+ FROM SNMPv2-SMI -- [RFC2578]
+ IANAifType
+ FROM IANAifType-MIB;
+
+-- saf OBJECT IDENTIFIER ::= { enterprises 7571 }
+-- microwaveRadio OBJECT IDENTIFIER ::= { tehnika 1 }
+-- pointToPoint OBJECT IDENTIFIER ::= { microwaveRadio 1 }
+-- safIntegra OBJECT IDENTIFIER ::= { pointToPoint 7 }
+
+integraX MODULE-IDENTITY
+ LAST-UPDATED "202006260000Z" -- 26 jun 2020
+ ORGANIZATION "SAF Tehnika"
+ CONTACT-INFO
+ "SAF Tehnika technical support
+ <techsupport@saftehnika.com>"
+ DESCRIPTION
+ "SAF Integra-X device management base"
+-- Revision history
+ REVISION "202006260000Z" -- 26 jun 2020
+ DESCRIPTION
+ "Added system services / firmware upgrade."
+ REVISION "202005190000Z" -- 19 may 2020
+ DESCRIPTION
+ "Added system services / reboot option."
+ REVISION "202005080000Z" -- 08 may 2020
+ DESCRIPTION
+ "ACM min/max modem modulation read-only support."
+ REVISION "202001140000Z" -- 14 jan 2020
+ DESCRIPTION
+ "Added LSP/Backup port status."
+ REVISION "201911270000Z" -- 27 nov 2019
+ DESCRIPTION
+ "Added system service sensors."
+ REVISION "201906110000Z" -- 11 jun 2019
+ DESCRIPTION
+ "Added device fan error status."
+ REVISION "201904230000Z" -- 23 apr 2019
+ DESCRIPTION
+ "Added device type, serial number and product code."
+ REVISION "201903070000Z" -- 07 mar 2019
+ DESCRIPTION
+ "Changed integraXifPortSpeed to integraXifPortHighSpeed, that will use Mbps instead of bps.
+ Added modem performance counters separately to modem A and modem B."
+ REVISION "201903060000Z" -- 06 mar 2019
+ DESCRIPTION
+ "Added modem A and B specific performance counters"
+ REVISION "201902170000Z" -- 17 feb 2019
+ DESCRIPTION
+ "Public Release 1.0"
+ ::= { safIntegra 10 }
+
+
+
+FixedDiv20 ::= TEXTUAL-CONVENTION
+ DISPLAY-HINT "d-2"
+ STATUS current
+ DESCRIPTION "Fixed point, two decimals"
+ SYNTAX Integer32
+
+FixedDiv10 ::= TEXTUAL-CONVENTION
+ DISPLAY-HINT "d-1"
+ STATUS current
+ DESCRIPTION "Fixed point, two decimals"
+ SYNTAX Integer32
+
+
+
+integraXtimestamp OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Last data update time"
+ ::= { integraX 1 }
+
+integraXradio OBJECT IDENTIFIER ::= { integraX 2 }
+
+--radio/radioA
+integraXradioA OBJECT IDENTIFIER ::= { integraXradio 1 }
+
+integraXradioAtxPower OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "dBm"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Output power of radio transmitter"
+ ::= { integraXradioA 1 }
+
+integraXradioAtxFrequency OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "kHz"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Frequency of radio transmitter"
+ ::= { integraXradioA 2 }
+
+integraXradioArxLevel OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "dBm"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Level of the received signal"
+ ::= { integraXradioA 3 }
+
+integraXradioArxLevelState OBJECT-TYPE
+ SYNTAX INTEGER {
+ ok(1),
+ low(2),
+ high(3),
+ error(4)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Received signal level state"
+ ::= { integraXradioA 4 }
+
+integraXradioAside OBJECT-TYPE
+ SYNTAX INTEGER {
+ high(1),
+ low(2),
+ error(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Radio side: Low/High"
+ ::= { integraXradioA 5 }
+
+integraXradioAtxMute OBJECT-TYPE
+ SYNTAX INTEGER {
+ on(1),
+ off(2),
+ error(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Status of 'Tx mute'
+ 1 - Tx is muted,
+ 2 - Tx is not muted.
+ 3 - Status information unavailable"
+ ::= { integraXradioA 6 }
+
+integraXradioAtxMuteDuration OBJECT-TYPE
+ SYNTAX Integer32(0..214748364)
+ UNITS "s"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Time remaning for Tx to be muted in seconds.
+ To turn mute on send number of seconds between 10 and MAX.
+ To turn mute off send 0.
+ GET will retrieve remaining duration for mute or
+ 0 if Tx mute is turned off."
+ ::= { integraXradioA 7 }
+
+integraXradioAduplexShift OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "kHz"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Utilized duplex shift in kHz"
+ ::= { integraXradioA 8 }
+
+integraXradioArxFrequency OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "kHz"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Frequency of radio receiver"
+ ::= { integraXradioA 9 }
+
+integraXradioAtemperature OBJECT-TYPE
+ SYNTAX FixedDiv10
+ UNITS "C"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Radio module temperature"
+ ::= { integraXradioA 10 }
+
+integraXradioApll OBJECT-TYPE
+ SYNTAX INTEGER {
+ error(1),
+ ok(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "PLL state of local-oscillator generator"
+ ::= { integraXradioA 11 }
+
+--Settable radio parameter range values
+
+integraXradioArangesTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IntegraXradioArangeEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Network interface port status data."
+ ::= { integraXradioA 12 }
+
+integraXradioArangeEntry OBJECT-TYPE
+ SYNTAX IntegraXradioArangeEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing network physical port status info."
+ INDEX { integraXradioArangeEntryIndex }
+ ::= { integraXradioArangesTable 1 }
+
+IntegraXradioArangeEntry ::=
+ SEQUENCE {
+ integraXradioArangeEntryIndex
+ Integer32,
+ integraXradioArangeDescr
+ DisplayString,
+ integraXradioArangeTxPower
+ Integer32,
+ integraXradioArangeTxFrequency
+ Integer32
+ }
+
+integraXradioArangeEntryIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..2)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A unique value, greater than zero, for each range
+ entry. Starts with 1 and is equal to a number of all range
+ parameters."
+ ::= { integraXradioArangeEntry 1 }
+
+integraXradioArangeDescr OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..255))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "'Minimal' and 'maximal' labels"
+ ::= { integraXradioArangeEntry 2 }
+
+integraXradioArangeTxPower OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "dBm"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Output power ranges for radio transmitter"
+ ::= { integraXradioArangeEntry 3 }
+
+integraXradioArangeTxFrequency OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "kHz"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Frequency ranges for radio transmitter"
+ ::= { integraXradioArangeEntry 4 }
+
+--radio/radioB
+integraXradioB OBJECT IDENTIFIER ::= { integraXradio 2 }
+
+integraXradioBtxPower OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "dBm"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Output power of radio transmitter"
+ ::= { integraXradioB 1 }
+
+integraXradioBtxFrequency OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "kHz"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Frequency of radio transmitter"
+ ::= { integraXradioB 2 }
+
+integraXradioBrxLevel OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "dBm"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Level of the received signal"
+ ::= { integraXradioB 3 }
+
+integraXradioBrxLevelState OBJECT-TYPE
+ SYNTAX INTEGER {
+ ok(1),
+ low(2),
+ high(3),
+ error(4)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Received signal level state"
+ ::= { integraXradioB 4 }
+
+integraXradioBside OBJECT-TYPE
+ SYNTAX INTEGER {
+ high(1),
+ low(2),
+ error(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Radio side: Low/High"
+ ::= { integraXradioB 5 }
+
+integraXradioBtxMute OBJECT-TYPE
+ SYNTAX INTEGER {
+ on(1),
+ off(2),
+ error(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Status of 'Tx mute'
+ 1 - Tx is muted,
+ 2 - Tx is not muted.
+ 3 - Status information unavailable"
+ ::= { integraXradioB 6 }
+
+integraXradioBtxMuteDuration OBJECT-TYPE
+ SYNTAX Integer32(0..214748364)
+ UNITS "s"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Time remaning for Tx to be muted in seconds.
+ To turn mute on send number of seconds between 10 and MAX.
+ To turn mute off send 0.
+ GET will retrieve remaining duration for mute or
+ 0 if Tx mute is turned off."
+ ::= { integraXradioB 7 }
+
+integraXradioBduplexShift OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "kHz"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Utilized duplex shift in kHz"
+ ::= { integraXradioB 8 }
+
+integraXradioBrxFrequency OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "kHz"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Frequency of radio receiver"
+ ::= { integraXradioB 9 }
+
+integraXradioBtemperature OBJECT-TYPE
+ SYNTAX FixedDiv10
+ UNITS "C"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Radio module temperature"
+ ::= { integraXradioB 10 }
+
+integraXradioBpll OBJECT-TYPE
+ SYNTAX INTEGER {
+ error(1),
+ ok(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "PLL state of local-oscillator generator"
+ ::= { integraXradioB 11 }
+
+--Settable radio parameter range values
+
+integraXradioBrangesTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IntegraXradioBrangeEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Network interface port status data."
+ ::= { integraXradioB 12 }
+
+integraXradioBrangeEntry OBJECT-TYPE
+ SYNTAX IntegraXradioBrangeEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing network physical port status info."
+ INDEX { integraXradioBrangeEntryIndex }
+ ::= { integraXradioBrangesTable 1 }
+
+IntegraXradioBrangeEntry ::=
+ SEQUENCE {
+ integraXradioBrangeEntryIndex
+ Integer32,
+ integraXradioBrangeDescr
+ DisplayString,
+ integraXradioBrangeTxPower
+ Integer32,
+ integraXradioBrangeTxFrequency
+ Integer32
+ }
+
+integraXradioBrangeEntryIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..2)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A unique value, greater than zero, for each range
+ entry. Starts with 1 and is equal to a number of all range
+ parameters."
+ ::= { integraXradioBrangeEntry 1 }
+
+integraXradioBrangeDescr OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..255))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "'Minimal' and 'maximal' labels"
+ ::= { integraXradioBrangeEntry 2 }
+
+integraXradioBrangeTxPower OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "dBm"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Output power ranges for radio transmitter"
+ ::= { integraXradioBrangeEntry 3 }
+
+integraXradioBrangeTxFrequency OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "kHz"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Frequency ranges for radio transmitter"
+ ::= { integraXradioBrangeEntry 4 }
+
+
+
+integraXmodem OBJECT IDENTIFIER ::= { integraX 3 }
+
+--modem/modemA
+integraXmodemA OBJECT IDENTIFIER ::= { integraXmodem 1 }
+
+integraXmodemAacquireStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ acquireInProgress(1),
+ acquireLocked(2),
+ acquireFailed(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "This is the current status of modem data acquire
+ when queried modem status.
+ For detailed info use modemAcquireLastStatusDetails."
+ ::= { integraXmodemA 1 }
+
+integraXmodemAnormalizedMse OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "dB"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Current normalized MSE value (floating point value multiplied by 10)"
+ ::= { integraXmodemA 2 }
+
+-- ldpcDecoderStress OBJECT-TYPE
+integraXmodemAfecLoad OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Decoder stress or FEC load value (floating point in textual representation)"
+ ::= { integraXmodemA 3 }
+--TODO: change to new parameter related to FEC load
+integraXmodemAxpdEst OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "dB"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "XPD Estimated value (floating point value multiplied by 10)"
+ ::= { integraXmodemA 4 }
+
+integraXmodemAacquireLastStatusDetails OBJECT-TYPE
+ SYNTAX INTEGER {
+ acquireLocked(1),
+ acquireSweep(4),
+ acquireMSEerror(5),
+ acquireBITerror(6),
+ acquireStopped(12),
+ acquireSMerror(13)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "This is the last status of successfull or unsuccessful modem data acquire"
+ ::= { integraXmodemA 5 }
+
+integraXmodemAtemperature OBJECT-TYPE
+ SYNTAX FixedDiv10
+ UNITS "C"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Modem DSP temperature"
+ ::= { integraXmodemA 6 }
+
+integraXmodemArxModulation OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Current (actual) Rx Modulation"
+ ::= { integraXmodemA 7 }
+
+integraXmodemAtxModulation OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Current (actual) Tx Modulation"
+ ::= { integraXmodemA 8 }
+
+integraXmodemArxCapacity OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "kb/s"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Rx ethernet capacity in kilobits per second"
+ ::= { integraXmodemA 9 }
+
+integraXmodemAtxCapacity OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "kb/s"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Tx ethernet capacity in kilobits per second"
+ ::= { integraXmodemA 10 }
+
+integraXmodemAacmEngine OBJECT-TYPE
+ SYNTAX INTEGER {
+ enabled(1),
+ disabled(2),
+ error(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "ACM engine status"
+ ::= { integraXmodemA 11 }
+
+integraXmodemAcarrierOffset OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "Hz"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Modem carrier offset"
+ ::= { integraXmodemA 12 }
+
+--modem A performance counters
+integraXmodemAcountTime OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "s"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Modem performance count time"
+ ::= { integraXmodemA 13 }
+
+integraXmodemAerroredBlock OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Modem performance errored blocks"
+ ::= { integraXmodemA 14 }
+
+integraXmodemAerroredSecond OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "s"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Modem performance errored seconds"
+ ::= { integraXmodemA 15 }
+
+integraXmodemAseverelyErroredSecond OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "s"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Modem performance severely errored seconds"
+ ::= { integraXmodemA 16 }
+
+integraXmodemAbackgroundBlockError OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Modem performance background block errors"
+ ::= { integraXmodemA 17 }
+
+integraXmodemAtotalBlockNumber OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Modem performance total block number"
+ ::= { integraXmodemA 18 }
+
+integraXmodemAerroredSecondRatio OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Modem performance errored second ratio"
+ ::= { integraXmodemA 19 }
+
+integraXmodemAseverelyErroredSecondRatio OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Modem performance severely errored second ratio"
+ ::= { integraXmodemA 20 }
+
+integraXmodemAbackgroundBlockErrorRatio OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Modem performance background block error ratio"
+ ::= { integraXmodemA 21 }
+
+integraXmodemAuptime OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "s"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Modem performance : uptime"
+ ::= { integraXmodemA 22 }
+
+integraXmodemAunavailtime OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "s"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Modem performance : unavailtime"
+ ::= { integraXmodemA 23 }
+
+integraXmodemAfecLdpcBlockCounter OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Modem FEC load block counter"
+ ::= { integraXmodemA 24 }
+
+integraXmodemAfecLdpcUncorrectedBlockCounter OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Modem FEC load uncorrected block counter"
+ ::= { integraXmodemA 25 }
+
+integraXmodemAfecLdpcUncorrectedPercent OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "%"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Modem FEC load uncorrected percent"
+ ::= { integraXmodemA 26 }
+
+integraXmodemAfecRsBlockCounter OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Modem FEC load RS block counter"
+ ::= { integraXmodemA 27 }
+
+integraXmodemAfecRsUncorrectedBlockCounter OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Modem FEC load RS uncorrected block counter"
+ ::= { integraXmodemA 28 }
+
+integraXmodemAmodulationACMmin OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Minimal modulation for ACM enabled profile"
+ ::= { integraXmodemA 29 }
+
+integraXmodemAmodulationACMmax OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Maximal modulation for ACM enabled profile"
+ ::= { integraXmodemA 30 }
+
+--modem/modemB
+integraXmodemB OBJECT IDENTIFIER ::= { integraXmodem 2 }
+
+integraXmodemBacquireStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ acquireInProgress(1),
+ acquireLocked(2),
+ acquireFailed(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "This is the current status of modem data acquire
+ when queried modem status.
+ For detailed info use modemAcquireLastStatusDetails."
+ ::= { integraXmodemB 1 }
+
+integraXmodemBnormalizedMse OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "dB"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Current normalized MSE value (floating point value multiplied by 10)"
+ ::= { integraXmodemB 2 }
+
+-- ldpcDecoderStress OBJECT-TYPE
+integraXmodemBfecLoad OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Decoder stress or FEC load value (floating point in textual representation)"
+ ::= { integraXmodemB 3 }
+
+integraXmodemBxpdEst OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "dB"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "XPD Estimated value (floating point value multiplied by 10)"
+ ::= { integraXmodemB 4 }
+
+integraXmodemBacquireLastStatusDetails OBJECT-TYPE
+ SYNTAX INTEGER {
+ acquireLocked(1),
+ acquireSweep(4),
+ acquireMSEerror(5),
+ acquireBITerror(6),
+ acquireStopped(12),
+ acquireSMerror(13)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "This is the last status of successfull or unsuccessful modem data acquire"
+ ::= { integraXmodemB 5 }
+
+integraXmodemBtemperature OBJECT-TYPE
+ SYNTAX FixedDiv10
+ UNITS "C"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Modem DSP temperature"
+ ::= { integraXmodemB 6 }
+
+integraXmodemBrxModulation OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Current (actual) Rx Modulation"
+ ::= { integraXmodemB 7 }
+
+integraXmodemBtxModulation OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Current (actual) Tx Modulation"
+ ::= { integraXmodemB 8 }
+
+integraXmodemBrxCapacity OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "kb/s"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Rx ethernet capacity in kilobits per second"
+ ::= { integraXmodemB 9 }
+
+integraXmodemBtxCapacity OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "kb/s"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Tx ethernet capacity in kilobits per second"
+ ::= { integraXmodemB 10 }
+
+integraXmodemBacmEngine OBJECT-TYPE
+ SYNTAX INTEGER {
+ enabled(1),
+ disabled(2),
+ error(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "ACM engine status"
+ ::= { integraXmodemB 11 }
+
+integraXmodemBcarrierOffset OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "Hz"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Modem carrier offset"
+ ::= { integraXmodemB 12 }
+
+--modem B performance counters
+integraXmodemBcountTime OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "s"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Modem performance count time"
+ ::= { integraXmodemB 13 }
+
+integraXmodemBerroredBlock OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Modem performance errored blocks"
+ ::= { integraXmodemB 14 }
+
+integraXmodemBerroredSecond OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "s"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Modem performance errored seconds"
+ ::= { integraXmodemB 15 }
+
+integraXmodemBseverelyErroredSecond OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "s"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Modem performance severely errored seconds"
+ ::= { integraXmodemB 16 }
+
+integraXmodemBbackgroundBlockError OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Modem performance background block errors"
+ ::= { integraXmodemB 17 }
+
+integraXmodemBtotalBlockNumber OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Modem performance total block number"
+ ::= { integraXmodemB 18 }
+
+integraXmodemBerroredSecondRatio OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Modem performance errored second ratio"
+ ::= { integraXmodemB 19 }
+
+integraXmodemBseverelyErroredSecondRatio OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Modem performance severely errored second ratio"
+ ::= { integraXmodemB 20 }
+
+integraXmodemBbackgroundBlockErrorRatio OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Modem performance background block error ratio"
+ ::= { integraXmodemB 21 }
+
+integraXmodemBuptime OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "s"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Modem performance : uptime"
+ ::= { integraXmodemB 22 }
+
+integraXmodemBunavailtime OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "s"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Modem performance : unavailtime"
+ ::= { integraXmodemB 23 }
+
+integraXmodemBfecLdpcBlockCounter OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Modem FEC load block counter"
+ ::= { integraXmodemB 24 }
+
+integraXmodemBfecLdpcUncorrectedBlockCounter OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Modem FEC load uncorrected block counter"
+ ::= { integraXmodemB 25 }
+
+integraXmodemBfecLdpcUncorrectedPercent OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "%"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Modem FEC load uncorrected percent"
+ ::= { integraXmodemB 26 }
+
+integraXmodemBfecRsBlockCounter OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Modem FEC load RS block counter"
+ ::= { integraXmodemB 27 }
+
+integraXmodemBfecRsUncorrectedBlockCounter OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Modem FEC load RS uncorrected block counter"
+ ::= { integraXmodemB 28 }
+
+integraXmodemBmodulationACMmin OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Minimal modulation for ACM enabled profile"
+ ::= { integraXmodemB 29 }
+
+integraXmodemBmodulationACMmax OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Maximal modulation for ACM enabled profile"
+ ::= { integraXmodemB 30 }
+
+--modem common
+
+integraXmodemBandwidth OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "kHz"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Signal bandwidth"
+ ::= { integraXmodem 3 }
+
+integraXmodemModulation OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Modulation (preferred)"
+ ::= { integraXmodem 4 }
+
+
+integraXsystem OBJECT IDENTIFIER ::= { integraX 4 }
+
+integraXsysCPUtemperature OBJECT-TYPE
+ SYNTAX FixedDiv10
+ UNITS "C"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "System CPU temperature"
+ ::= { integraXsystem 2 }
+
+integraXsysLicenseExpire OBJECT-TYPE
+ SYNTAX Gauge32
+ UNITS "s"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "License expires after number of seconds.
+ In the case of -1, check licenseGenStatus status"
+ ::= { integraXsystem 3 }
+integraXsysLicenseGenStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ ok(1),
+ expired(2),
+ unknown(3),
+ unlimitedTime(4)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "License General status."
+ ::= { integraXsystem 4 }
+
+integraXsysPSUvoltage OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "mV"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Power voltage in mV"
+ ::= { integraXsystem 5 }
+
+integraXsysPSUcurrent OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "mA"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Power current in mA"
+ ::= { integraXsystem 6 }
+integraXsysPSUpower OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "mW"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Power consumption in mW"
+ ::= { integraXsystem 7 }
+integraXsysBoardTemperature OBJECT-TYPE
+ SYNTAX FixedDiv10
+ UNITS "C"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "System temperature"
+ ::= { integraXsystem 8 }
+integraXsysFreeMemory OBJECT-TYPE
+ SYNTAX FixedDiv10
+ UNITS "%"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "System free memory"
+ ::= { integraXsystem 9 }
+integraXsysCPUidle OBJECT-TYPE
+ SYNTAX FixedDiv10
+ UNITS "%"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "System CPU idle"
+ ::= { integraXsystem 10 }
+
+integraXsysDeviceType OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Device type name"
+ ::= { integraXsystem 11 }
+
+integraXsysDeviceSerial OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Device serial number"
+ ::= { integraXsystem 12 }
+
+integraXsysDeviceProductModel OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Device product model code"
+ ::= { integraXsystem 13 }
+
+integraXsysFanError OBJECT-TYPE
+ SYNTAX BITS {
+ no(0),
+ fan1(1),
+ fan2(2),
+ unknown(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Device fan 1 and fan 2 error status"
+ ::= { integraXsystem 14 }
+
+-- service sensors
+integraXsysSw1v0core OBJECT-TYPE
+ SYNTAX FixedDiv20
+ UNITS "V"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "SW_1V0_CORE"
+ ::= { integraXsystem 15 }
+
+integraXsysSw1v0avdd OBJECT-TYPE
+ SYNTAX FixedDiv20
+ UNITS "V"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "SW_1V0_AVDD"
+ ::= { integraXsystem 16 }
+
+integraXsysSw1v2a OBJECT-TYPE
+ SYNTAX FixedDiv20
+ UNITS "V"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "SW_1V2A"
+ ::= { integraXsystem 17 }
+
+integraXsysSw1v5ddr OBJECT-TYPE
+ SYNTAX FixedDiv20
+ UNITS "V"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "SW_1V5_DDR"
+ ::= { integraXsystem 18 }
+
+integraXsysSw1v8 OBJECT-TYPE
+ SYNTAX FixedDiv20
+ UNITS "V"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "SW_1V8"
+ ::= { integraXsystem 19 }
+
+integraXsysSw2v5 OBJECT-TYPE
+ SYNTAX FixedDiv20
+ UNITS "V"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "SW_2V5"
+ ::= { integraXsystem 20 }
+
+integraXsysSw3v3 OBJECT-TYPE
+ SYNTAX FixedDiv20
+ UNITS "V"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "SW_3V3"
+ ::= { integraXsystem 21 }
+
+integraXsysVttrefPs OBJECT-TYPE
+ SYNTAX FixedDiv20
+ UNITS "V"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "VTTVREF_PS"
+ ::= { integraXsystem 22 }
+
+integraXsysVttddrPs OBJECT-TYPE
+ SYNTAX FixedDiv20
+ UNITS "V"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "VTTDDR_PS"
+ ::= { integraXsystem 23 }
+
+integraXsysZq1v0 OBJECT-TYPE
+ SYNTAX FixedDiv20
+ UNITS "V"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "ZQ_1V0"
+ ::= { integraXsystem 24 }
+
+integraXsysZq1v5 OBJECT-TYPE
+ SYNTAX FixedDiv20
+ UNITS "V"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "ZQ_1V5"
+ ::= { integraXsystem 25 }
+
+integraXsysZq1v8 OBJECT-TYPE
+ SYNTAX FixedDiv20
+ UNITS "V"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "ZQ_1V8"
+ ::= { integraXsystem 26 }
+
+integraXsysZq2v5 OBJECT-TYPE
+ SYNTAX FixedDiv20
+ UNITS "V"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "ZQ_2V5"
+ ::= { integraXsystem 27 }
+
+integraXsysZq3v3 OBJECT-TYPE
+ SYNTAX FixedDiv20
+ UNITS "V"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "ZQ_3V3"
+ ::= { integraXsystem 28 }
+
+integraXsys5v0d OBJECT-TYPE
+ SYNTAX FixedDiv20
+ UNITS "V"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "5V0D"
+ ::= { integraXsystem 29 }
+
+integraXsysSw1v2 OBJECT-TYPE
+ SYNTAX FixedDiv20
+ UNITS "V"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "SW_1V2"
+ ::= { integraXsystem 30 }
+
+integraXsysMdmVddcAvs OBJECT-TYPE
+ SYNTAX FixedDiv20
+ UNITS "V"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "MDM_VDDC_AVS"
+ ::= { integraXsystem 31 }
+
+integraXsysMdm3v3 OBJECT-TYPE
+ SYNTAX FixedDiv20
+ UNITS "V"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "MDM_3V3"
+ ::= { integraXsystem 32 }
+
+integraXsysMdm1v0aPm OBJECT-TYPE
+ SYNTAX FixedDiv20
+ UNITS "V"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "MDM_1V0A_PM"
+ ::= { integraXsystem 33 }
+
+integraXsysMdm1v0a OBJECT-TYPE
+ SYNTAX FixedDiv20
+ UNITS "V"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "MDM_1V0A"
+ ::= { integraXsystem 34 }
+
+integraXsysMdm1v8a OBJECT-TYPE
+ SYNTAX FixedDiv20
+ UNITS "V"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "MDM_1V8A"
+ ::= { integraXsystem 35 }
+
+integraXsysMdmDAC02v5a OBJECT-TYPE
+ SYNTAX FixedDiv20
+ UNITS "V"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "MDM_DAC0_2V5A"
+ ::= { integraXsystem 36 }
+
+integraXsysMdmDAC12v5 OBJECT-TYPE
+ SYNTAX FixedDiv20
+ UNITS "V"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "MDM_DAC1_2V5A"
+ ::= { integraXsystem 37 }
+
+integraXsysMdmDAC22v5 OBJECT-TYPE
+ SYNTAX FixedDiv20
+ UNITS "V"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "MDM_DAC2_2V5A"
+ ::= { integraXsystem 38 }
+
+integraXsysMdm1v8io OBJECT-TYPE
+ SYNTAX FixedDiv20
+ UNITS "V"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "MDM_1V8_IO"
+ ::= { integraXsystem 39 }
+
+integraXsysMdm3v3io OBJECT-TYPE
+ SYNTAX FixedDiv20
+ UNITS "V"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "MDM_3V3_IO"
+ ::= { integraXsystem 40 }
+
+integraXsys3v3Radio OBJECT-TYPE
+ SYNTAX FixedDiv20
+ UNITS "V"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "3V3_RADIO"
+ ::= { integraXsystem 41 }
+
+integraXsysMdm4v0 OBJECT-TYPE
+ SYNTAX FixedDiv20
+ UNITS "V"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "MDM_4V0"
+ ::= { integraXsystem 42 }
+
+integraXsys5v0nRadio OBJECT-TYPE
+ SYNTAX FixedDiv20
+ UNITS "V"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "5V0N_RADIO"
+ ::= { integraXsystem 43 }
+
+integraXsysCoreVddSns OBJECT-TYPE
+ SYNTAX FixedDiv20
+ UNITS "V"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "CORE_VDD_SNS"
+ ::= { integraXsystem 44 }
+
+integraXsys40v0RadioSns OBJECT-TYPE
+ SYNTAX FixedDiv20
+ UNITS "V"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "40V0_RADIO_SNS"
+ ::= { integraXsystem 45 }
+
+integraXsysServices OBJECT IDENTIFIER ::= { integraXsystem 46 }
+
+integraXsysServicesReboot OBJECT-TYPE
+ SYNTAX INTEGER {
+ reboot(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "This object can only be set to 1.
+ It initiates system reboot immediately."
+ ::= { integraXsysServices 1 }
+
+integraXsysServicesFtpSwitch OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(1),
+ enabled(2),
+ unknown(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Status and on/off switch for the FTP server"
+ ::= { integraXsysServices 2 }
+
+integraXsysServicesFwCurrInfo OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..255))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Currently running FW info.
+ Same output as in RFC1213-MIB::sysDescr."
+ ::= { integraXsysServices 3 }
+
+integraXsysServicesFwAvailView OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "List FW available for installation (uploaded)."
+ ::= { integraXsysServices 4 }
+
+integraXsysServicesFwRemove OBJECT-TYPE
+ SYNTAX INTEGER {
+ candfw1(1),
+ candfw2(2),
+ candfw3(3),
+ candfw4(4),
+ candfw5(5)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Remove available (uploaded) FW version.
+ View FW versions in integraXsysServicesFwAvailView.
+ Send number corresponding to info in integraXsysServicesFwAvailView."
+ ::= { integraXsysServices 5 }
+
+integraXsysServicesFwRemoveAll OBJECT-TYPE
+ SYNTAX INTEGER {
+ removeAllCandfw(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Remove all available (uploaded) FW versions."
+ ::= { integraXsysServices 6 }
+
+integraXsysServicesFwUpload OBJECT-TYPE
+ SYNTAX INTEGER {
+ upload(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Upload FW (make available for installation).
+ You need to upload a firmware to FTP ftp://anonymous@DEVICE_IP:/firmware/ first!
+ You must have only 1 firmware in firmware folder for this option to work!
+ This option only starts upload on the device and doesn't return success status for it.
+ Usually you should wait some time while the device completes upload.
+ SNMP won't response to quieries while upload is in progress.
+ You may check integraXsysServicesFwAvailView to see if your FW is ready for install."
+ ::= { integraXsysServices 7 }
+
+integraXsysServicesFwInst OBJECT-TYPE
+ SYNTAX INTEGER {
+ candfw1(1),
+ candfw2(2),
+ candfw3(3),
+ candfw4(4),
+ candfw5(5)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Install FW version.
+ You need check integraXsysServicesFwAvailView to see FW versions ready for install.
+ This option only starts installation on the device and doesn't return success status for it.
+ Usually you should wait some time while the device completes installation.
+ SNMP won't response to quieries while upload is in progress.
+ If FW installation was successful, integraXsysServicesFwSwitchNext will show
+ different FW bank value for the next boot."
+ ::= { integraXsysServices 8 }
+
+integraXsysServicesFwSwitchRunning OBJECT-TYPE
+ SYNTAX INTEGER {
+ fw1(1),
+ fw2(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "FW running bank info.
+ Use integraXsysServicesFwSwitchNext to view and switch FW bank for the next boot."
+ ::= { integraXsysServices 9 }
+
+integraXsysServicesFwSwitchNext OBJECT-TYPE
+ SYNTAX INTEGER {
+ fw1(1),
+ fw2(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "FW next boot bank info. Set request can change FW bank for the next boot.
+ View running FW bank number in integraXsysServicesFwSwitchRunning."
+ ::= { integraXsysServices 10 }
+
+
+-- Ethernet
+integraXethernet OBJECT IDENTIFIER ::= { integraX 5 }
+ -- Port status
+integraXifStatusTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IntegraXifPortEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Network interface port status data."
+ ::= { integraXethernet 1 }
+
+integraXifPortEntry OBJECT-TYPE
+ SYNTAX IntegraXifPortEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing network physical port status info."
+ INDEX { integraXifPortStatIndex }
+ ::= { integraXifStatusTable 1 }
+
+IntegraXifPortEntry ::=
+ SEQUENCE {
+ integraXifPortStatIndex
+ Integer32,
+ integraXifPortStatDescr
+ DisplayString,
+ integraXifPortType
+ IANAifType,
+ integraXifPortMtu
+ Integer32,
+ integraXifPortHighSpeed
+ Gauge32,
+ integraXifPortPhysAddress
+ PhysAddress,
+ integraXifPortAdminStatus
+ INTEGER,
+ integraXifPortOperStatus
+ INTEGER,
+ integraXifPortLastChange
+ TimeTicks,
+ integraXifPortAutoneg
+ INTEGER,
+ integraXifPortDuplex
+ INTEGER,
+ integraXifPortSyncEthActive
+ INTEGER,
+ integraXifPortSyncEthPrio
+ Integer32,
+ integraXifPortFlowControl
+ INTEGER
+ }
+
+integraXifPortStatIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..4)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A unique value, greater than zero, for each physical
+ network interface. It is recommended that
+ values are assigned contiguously starting from 1."
+ ::= { integraXifPortEntry 1 }
+
+integraXifPortStatDescr OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..255))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Physical network interface description.
+ LAN1 is electrical, LAN2 and LAN3 are SFP
+ and WAN is radio port."
+ ::= { integraXifPortEntry 2 }
+
+integraXifPortType OBJECT-TYPE
+ SYNTAX IANAifType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The type of interface, distinguished according to
+ the physical/link protocol(s) immediately `below'
+ the network layer in the protocol stack."
+ ::= { integraXifPortEntry 3 }
+
+integraXifPortMtu OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "B"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Maximum transmission unit value in bytes."
+ ::= { integraXifPortEntry 4 }
+
+integraXifPortHighSpeed OBJECT-TYPE
+ SYNTAX Gauge32
+ UNITS "Mbps"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Link speed in 1 000 000 * bits per second."
+ ::= { integraXifPortEntry 5 }
+
+integraXifPortPhysAddress OBJECT-TYPE
+ SYNTAX PhysAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The interface's address at the protocol layer
+ immediately `below' the network layer in the
+ protocol stack. For interfaces which do not have
+ such an address (e.g., a serial line), this object
+ should contain an octet string of zero length."
+ ::= { integraXifPortEntry 6 }
+
+integraXifPortAdminStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ enabled(1),
+ disabled(2),
+ unknown(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Desired state of network interfaces. Interfaces
+ can be enabled(1), disabled(2), unknown(3) (no info received)."
+ ::= { integraXifPortEntry 7 }
+
+integraXifPortOperStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ up(1),
+ down(2),
+ unknown(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Actual state of interfaces. Link can be up(1),
+ down(2) or in unknown(3) state."
+ ::= { integraXifPortEntry 8 }
+
+integraXifPortLastChange OBJECT-TYPE
+ SYNTAX TimeTicks
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This parameter value is always 0 at the moment."
+ ::= { integraXifPortEntry 9 }
+
+integraXifPortAutoneg OBJECT-TYPE
+ SYNTAX INTEGER {
+ enabled(1),
+ disabled(2),
+ unknown(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Auto-negotiation status. Unknown means no info was received."
+ ::= { integraXifPortEntry 10 }
+
+integraXifPortDuplex OBJECT-TYPE
+ SYNTAX INTEGER {
+ full(1),
+ half(2),
+ unknown(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Duplex status for the interface."
+ ::= { integraXifPortEntry 11 }
+
+integraXifPortSyncEthActive OBJECT-TYPE
+ SYNTAX INTEGER {
+ off(0),
+ on(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Synchronous Ethernet status.
+ Can be active(1) or inactive(0)."
+ ::= { integraXifPortEntry 12 }
+
+integraXifPortSyncEthPrio OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Synchronous Ethernet priority."
+ ::= { integraXifPortEntry 13 }
+
+integraXifPortFlowControl OBJECT-TYPE
+ SYNTAX INTEGER {
+ enabled(1),
+ disabled(2),
+ unknown(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Flow control status."
+ ::= { integraXifPortEntry 14 }
+
+
+ -- Port statistics
+integraXifStatisticsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IntegraXifPortStcEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Network interface port statistics data."
+ ::= { integraXethernet 2 }
+
+integraXifPortStcEntry OBJECT-TYPE
+ SYNTAX IntegraXifPortStcEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing network physical port statistics counter data."
+ INDEX { integraXifPortStcIndex }
+ ::= { integraXifStatisticsTable 1 }
+
+IntegraXifPortStcEntry ::=
+ SEQUENCE {
+ integraXifPortStcIndex
+ Integer32,
+ integraXifPortStcDescr
+ DisplayString,
+ integraXifTimePassed
+ TimeTicks,
+ integraXifIngressPackets
+ Counter64,
+ integraXifIngressBytes
+ Counter64,
+ integraXifEgressPackets
+ Counter64,
+ integraXifEgressBytes
+ Counter64,
+ integraXifEtherStatsMulticastPkts
+ Counter64,
+ integraXifEtherStatsBroadcastPkts
+ Counter64,
+ integraXifEtherStatsPkts64Octets
+ Counter64,
+ integraXifEtherStatsPkts65to127Octets
+ Counter64,
+ integraXifEtherStatsPkts128to255Octets
+ Counter64,
+ integraXifEtherStatsPkts256to511Octets
+ Counter64,
+ integraXifEtherStatsPkts512to1023Octets
+ Counter64,
+ integraXifEtherStatsPkts1024to1518Octets
+ Counter64,
+ integraXifEtherStatsOversizePkts
+ Counter64,
+ integraXifEtherRxOversizePkts
+ Counter64,
+ integraXifEtherTxOversizePkts
+ Counter64,
+ integraXifEtherStatsOctets
+ Counter64,
+ integraXifEtherStatsPkts
+ Counter64,
+ integraXifEtherStatsTXNoErrors
+ Counter64,
+ integraXifEtherStatsRXNoErrors
+ Counter64,
+ integraXifEtherStatsPkts1519to1522Octets
+ Counter64,
+ integraXifIfInOctets
+ Counter64,
+ integraXifIfOutOctets
+ Counter64,
+ integraXifDot1dTpPortInFrames
+ Counter64,
+ integraXifDot1dTpPortOutFrames
+ Counter64,
+ integraXifReceivedPkts64Octets
+ Counter64,
+ integraXifTransmittedPkts64Octets
+ Counter64,
+ integraXifReceivedPkts65to127Octets
+ Counter64,
+ integraXifTransmittedPkts65to127Octets
+ Counter64,
+ integraXifReceivedPkts128to255Octets
+ Counter64,
+ integraXifTransmittedPkts128to255Octets
+ Counter64,
+ integraXifReceivedPkts256to511Octets
+ Counter64,
+ integraXifTransmittedPkts256to511Octets
+ Counter64,
+ integraXifReceivedPkts512to1023Octets
+ Counter64,
+ integraXifTransmittedPkts512to1023Octets
+ Counter64,
+ integraXifReceivedPkts1024to1518Octets
+ Counter64,
+ integraXifTransmittedPkts1024to1518Octets
+ Counter64,
+ integraXifIfInBroadcastPkts
+ Counter64,
+ integraXifIfOutBroadcastPkts
+ Counter64,
+ integraXifIfInMulticastPkts
+ Counter64,
+ integraXifIfOutMulticastPkts
+ Counter64,
+ integraXifDot3InPauseFrames
+ Counter64,
+ integraXifDot3OutPauseFrames
+ Counter64,
+ integraXifEtherStatsUndersizePkts
+ Counter64,
+ integraXifEtherStatsFragments
+ Counter64,
+ integraXifEtherStatsCRCAlignErrors
+ Counter64,
+ integraXifEtherStatsJabbers
+ Counter64,
+ integraXifIngressBPS
+ Integer32,
+ integraXifIngressPPS
+ Integer32,
+ integraXifEgressBPS
+ Integer32,
+ integraXifEgressPPS
+ Integer32,
+ integraXifAllCoSQoutPackets
+ Counter64,
+ integraXifAllCoSQoutBytes
+ Counter64,
+ integraXifAllCoSQdroppedPackets
+ Counter64,
+ integraXifAllCoSQdroppedBytes
+ Counter64,
+ integraXifProcessedRxPackets
+ Counter64,
+ integraXifProcessedRxBytes
+ Counter64
+ }
+
+integraXifPortStcIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..5)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A unique value, greater than zero, for each physical
+ network interface. It is recommended that
+ values are assigned contiguously starting from 1."
+ ::= { integraXifPortStcEntry 1 }
+
+integraXifPortStcDescr OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..255))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Physical network interface description.
+ LAN1 is electrical, LAN2 and LAN3 are SFP,
+ WAN is radio port and MNG is internal management interface."
+ ::= { integraXifPortStcEntry 2 }
+
+integraXifTimePassed OBJECT-TYPE
+ SYNTAX TimeTicks
+ UNITS "s/100"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Statistics collection time."
+ ::= { integraXifPortStcEntry 3 }
+
+integraXifIngressPackets OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Packets that ingress on the port."
+ ::= { integraXifPortStcEntry 4 }
+
+integraXifIngressBytes OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "B"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Bytes that ingress on the port."
+ ::= { integraXifPortStcEntry 5 }
+
+integraXifEgressPackets OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Packets that egress on the port."
+ ::= { integraXifPortStcEntry 6 }
+
+integraXifEgressBytes OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "B"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Bytes that egress on the port."
+ ::= { integraXifPortStcEntry 7 }
+
+integraXifEtherStatsMulticastPkts OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of good packets (both received and
+ transmitted) that were directed to a multicast address.
+ Note that this number does not include packets directed
+ to the broadcast address."
+ ::= { integraXifPortStcEntry 8 }
+
+integraXifEtherStatsBroadcastPkts OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of good packets (both received and
+ transmitted) that were directed to the broadcast address.
+ Note that this does not include multicast packets."
+ ::= { integraXifPortStcEntry 9 }
+
+integraXifEtherStatsPkts64Octets OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of packets (including bad
+ packets) (both received and transmitted)
+ that were 64 octets in length
+ (excluding framing bits but including FCS octets)."
+ ::= { integraXifPortStcEntry 10 }
+
+integraXifEtherStatsPkts65to127Octets OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of packets (including bad
+ packets) (both received and transmitted)
+ that were between 65 and 127 octets in length inclusive
+ (excluding framing bits but including FCS octets)."
+ ::= { integraXifPortStcEntry 11 }
+
+integraXifEtherStatsPkts128to255Octets OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of packets (including bad
+ packets) (both received and transmitted) that were
+ between 128 and 255 octets in length inclusive
+ (excluding framing bits but including FCS octets)."
+ ::= { integraXifPortStcEntry 12 }
+
+integraXifEtherStatsPkts256to511Octets OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of packets (including bad
+ packets) (both received and transmitted) that were
+ between 256 and 511 octets in length inclusive
+ (excluding framing bits but including FCS octets)."
+ ::= { integraXifPortStcEntry 13 }
+
+integraXifEtherStatsPkts512to1023Octets OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of packets (including bad
+ packets) (both received and transmitted) that were
+ between 512 and 1023 octets in length inclusive
+ (excluding framing bits but including FCS octets)."
+ ::= { integraXifPortStcEntry 14 }
+
+integraXifEtherStatsPkts1024to1518Octets OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of packets (including bad
+ packets) (both received and transmitted) that were
+ between 1024 and 1518 octets in length inclusive
+ (excluding framing bits but including FCS octets)."
+ ::= { integraXifPortStcEntry 15 }
+
+integraXifEtherStatsOversizePkts OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of packets (both received and
+ transmitted) that were longer than 1518
+ octets (excluding framing bits but including
+ FCS octets) but were otherwise well formed."
+ ::= { integraXifPortStcEntry 16 }
+
+integraXifEtherRxOversizePkts OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of packets received
+ that were longer than 1518 octets
+ (excluding framing bits but including
+ FCS octets) but were otherwise well formed."
+ ::= { integraXifPortStcEntry 17 }
+
+integraXifEtherTxOversizePkts OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of packets transmitted
+ that were longer than 1518 octets
+ (excluding framing bits but including
+ FCS octets) but were otherwise well formed."
+ ::= { integraXifPortStcEntry 18 }
+
+integraXifEtherStatsOctets OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of octets of data (including
+ those in bad packets) both received and
+ transmitted."
+ ::= { integraXifPortStcEntry 19 }
+
+integraXifEtherStatsPkts OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of packets (including bad packets)
+ both received and transmitted."
+ ::= { integraXifPortStcEntry 20 }
+
+integraXifEtherStatsTXNoErrors OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of packets that were transmitted
+ without errors."
+ ::= { integraXifPortStcEntry 21 }
+
+integraXifEtherStatsRXNoErrors OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of packets that were received
+ without errors."
+ ::= { integraXifPortStcEntry 22 }
+
+integraXifEtherStatsPkts1519to1522Octets OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of packets (including bad
+ packets) (both received and transmitted) that were
+ between 1519 and 1522 octets in length inclusive
+ (excluding framing bits but including FCS octets)."
+ ::= { integraXifPortStcEntry 23 }
+
+integraXifIfInOctets OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "octet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of octets of data (including
+ those in bad packets) that were received."
+ ::= { integraXifPortStcEntry 24 }
+
+integraXifIfOutOctets OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "octet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of octets of data (including
+ those in bad packets) that were transmitted."
+ ::= { integraXifPortStcEntry 25 }
+
+integraXifDot1dTpPortInFrames OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "frame"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of frames that have been received by
+ this port from its segment."
+ ::= { integraXifPortStcEntry 26 }
+
+integraXifDot1dTpPortOutFrames OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "frame"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of frames that have been transmitted by
+ this port to its segment."
+ ::= { integraXifPortStcEntry 27 }
+
+integraXifReceivedPkts64Octets OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of received packets that were
+ 64 octets in length (excluding framing bits
+ but including FCS octets)."
+ ::= { integraXifPortStcEntry 28 }
+
+integraXifTransmittedPkts64Octets OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of transmitted packets that were
+ 64 octets in length (excluding framing bits
+ but including FCS octets)."
+ ::= { integraXifPortStcEntry 29 }
+
+integraXifReceivedPkts65to127Octets OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of received packets that were
+ between 65 and 127 octets in length inclusive
+ (excluding framing bits but including FCS octets)."
+ ::= { integraXifPortStcEntry 30 }
+
+integraXifTransmittedPkts65to127Octets OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of transmitted packets that were
+ between 65 and 127 octets in length inclusive
+ (excluding framing bits but including FCS octets)."
+ ::= { integraXifPortStcEntry 31 }
+
+integraXifReceivedPkts128to255Octets OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of received packets that were
+ between 128 and 255 octets in length inclusive
+ (excluding framing bits but including FCS octets)."
+ ::= { integraXifPortStcEntry 32 }
+
+integraXifTransmittedPkts128to255Octets OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of transmitted packets that were
+ between 128 and 255 octets in length inclusive
+ (excluding framing bits but including FCS octets)."
+ ::= { integraXifPortStcEntry 33 }
+
+integraXifReceivedPkts256to511Octets OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of received packets that were
+ between 256 and 511 octets in length inclusive
+ (excluding framing bits but including FCS octets)."
+ ::= { integraXifPortStcEntry 34 }
+
+integraXifTransmittedPkts256to511Octets OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of transmitted packets that were
+ between 256 and 511 octets in length inclusive
+ (excluding framing bits but including FCS octets)."
+ ::= { integraXifPortStcEntry 35 }
+
+integraXifReceivedPkts512to1023Octets OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of received packets that were
+ between 512 and 1023 octets in length inclusive
+ (excluding framing bits but including FCS octets)."
+ ::= { integraXifPortStcEntry 36 }
+
+integraXifTransmittedPkts512to1023Octets OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of transmitted packets that were
+ between 512 and 1023 octets in length inclusive
+ (excluding framing bits but including FCS octets)."
+ ::= { integraXifPortStcEntry 37 }
+
+integraXifReceivedPkts1024to1518Octets OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of received packets that were
+ between 1024 and 1518 octets in length inclusive
+ (excluding framing bits but including FCS octets)."
+ ::= { integraXifPortStcEntry 38 }
+
+integraXifTransmittedPkts1024to1518Octets OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of transmitted packets that were
+ between 1024 and 1518 octets in length inclusive
+ (excluding framing bits but including FCS octets)."
+ ::= { integraXifPortStcEntry 39 }
+
+integraXifIfInBroadcastPkts OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of received good packets
+ that were directed to the broadcast address.
+ Note that this does not include multicast packets."
+ ::= { integraXifPortStcEntry 40 }
+
+integraXifIfOutBroadcastPkts OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of transmitted good packets
+ that were directed to the broadcast address.
+ Note that this does not include multicast packets."
+ ::= { integraXifPortStcEntry 41 }
+
+integraXifIfInMulticastPkts OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of received good packets
+ that were directed to a multicast address.
+ Note that this number does not include broadcast packets."
+ ::= { integraXifPortStcEntry 42 }
+
+integraXifIfOutMulticastPkts OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of transmitted good packets
+ that were directed to a multicast address.
+ Note that this number does not include broadcast packets."
+ ::= { integraXifPortStcEntry 43 }
+
+integraXifDot3InPauseFrames OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "frame"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A count of MAC Control frames received on this
+ interface with an opcode indicating the PAUSE
+ operation.
+ This counter does not increment when the
+ interface is operating in half-duplex mode."
+ ::= { integraXifPortStcEntry 44 }
+
+integraXifDot3OutPauseFrames OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "frame"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A count of MAC Control frames transmitted on
+ this interface with an opcode indicating the
+ PAUSE operation.
+ This counter does not increment when the
+ interface is operating in half-duplex mode."
+ ::= { integraXifPortStcEntry 45 }
+
+integraXifEtherStatsUndersizePkts OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of packets received that were
+ less than 64 octets long (excluding framing bits,
+ but including FCS octets) and were otherwise well
+ formed."
+ ::= { integraXifPortStcEntry 46 }
+
+integraXifEtherStatsFragments OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of packets received that were less than
+ 64 octets in length (excluding framing bits but including
+ FCS octets) and had either a bad Frame Check Sequence
+ (FCS) with an integral number of octets (FCS Error) or a
+ bad FCS with a non-integral number of octets (Alignment
+ Error).
+ Note that it is entirely normal for etherStatsFragments to
+ increment. This is because it counts both runts (which are
+ normal occurrences due to collisions) and noise hits."
+ ::= { integraXifPortStcEntry 47 }
+
+integraXifEtherStatsCRCAlignErrors OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of packets received that
+ had a length (excluding framing bits, but
+ including FCS octets) of between 64 and 1518
+ octets, inclusive, but had either a bad
+ Frame Check Sequence (FCS) with an integral
+ number of octets (FCS Error) or a bad FCS with
+ a non-integral number of octets (Alignment Error)."
+ ::= { integraXifPortStcEntry 48 }
+
+integraXifEtherStatsJabbers OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of packets received that were
+ longer than 1518 octets (excluding framing bits,
+ but including FCS octets), and had either a bad
+ Frame Check Sequence (FCS) with an integral number
+ of octets (FCS Error) or a bad FCS with a non-integral
+ number of octets (Alignment Error).
+ Note that this definition of jabber is different
+ than the definition in IEEE-802.3 section 8.2.1.5
+ (10BASE5) and section 10.3.1.4 (10BASE2). These
+ documents define jabber as the condition where any
+ packet exceeds 20 ms. The allowed range to detect
+ jabber is between 20 ms and 150 ms."
+ ::= { integraXifPortStcEntry 49 }
+
+integraXifIngressBPS OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "Bps"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Ingoing data transfer rate in bytes per second."
+ ::= { integraXifPortStcEntry 50 }
+
+integraXifIngressPPS OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "pps"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Ingoing data transfer rate in packets per second."
+ ::= { integraXifPortStcEntry 51 }
+
+integraXifEgressBPS OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "Bps"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Outgoing data transfer rate in bytes per second."
+ ::= { integraXifPortStcEntry 52 }
+
+integraXifEgressPPS OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "pps"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Outgoing data transfer rate in packets per second."
+ ::= { integraXifPortStcEntry 53 }
+
+integraXifAllCoSQoutPackets OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "All CoSQ outgoing packets."
+ ::= { integraXifPortStcEntry 54 }
+
+integraXifAllCoSQoutBytes OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "B"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "All CoSQ outgoing bytes."
+ ::= { integraXifPortStcEntry 55 }
+
+integraXifAllCoSQdroppedPackets OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "All CoSQ dropped packets."
+ ::= { integraXifPortStcEntry 56 }
+
+integraXifAllCoSQdroppedBytes OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "B"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "All CoSQ dropped bytes."
+ ::= { integraXifPortStcEntry 57 }
+
+integraXifProcessedRxPackets OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Processed received packets."
+ ::= { integraXifPortStcEntry 58 }
+
+integraXifProcessedRxBytes OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "B"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Processed received bytes."
+ ::= { integraXifPortStcEntry 59 }
+
+integraXifLspPortAdminState OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(1),
+ lsp(2),
+ backup(3),
+ unknown(4)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "LSP port status."
+ ::= { integraXethernet 3 }
+
+integraXifLspPortList OBJECT-TYPE
+ SYNTAX BITS {
+ none(0),
+ lan1(1),
+ lan2(2),
+ lan3(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "LSP port status."
+ ::= { integraXethernet 4 }
+
+integraXifLspPortStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ lspPortOK(1),
+ lspPortDownBlockedByLSP(2),
+ backupNoLink(3),
+ backupLinkActive(4),
+ backupLinkReady(5),
+ unknown(6)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "LSP port status."
+ ::= { integraXethernet 5 }
+
+
+
+-- Configuration applying/saving objects
+
+integraXexecuteConfig OBJECT-TYPE
+ SYNTAX INTEGER {
+ execute(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "This object can only be set to 1.
+ It initiates new running configuration
+ applying using values, that have been set before.
+ Setting it when no new changes are available
+ will do nothing and return an error.
+ GET will return 0 if there were no errors,
+ while executing configuration or will return
+ a bitmask, that shows which SET requests have failed.
+ Those failed requests will be shown bit wise
+ from LSB as follows:
+ BIT0 radioTxMuteDuration
+ BIT1 radioTxFrequency
+ BIT2 radioTxPower"
+ ::= { integraX 6 }
+
+integraXneedStore OBJECT-TYPE
+ SYNTAX INTEGER {
+ no(0)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "This object shows if there is unsaved,
+ but executed (running) configuration.
+ Unsaved changes will be lost after
+ device reboot. Unsaved entities are shown
+ bit wise, starting from LSB as follows:
+ BIT0 Aggregation
+ BIT1 Event log
+ BIT2 Modem
+ BIT3 Network
+ BIT4 Performance
+ BIT5 Radio
+ BIT6 SNMP
+ BIT7 Synchronous Ethernet
+ BIT8 System"
+ ::= { integraX 7 }
+
+integraXstoreConfig OBJECT-TYPE
+ SYNTAX INTEGER {
+ store(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "This object can only be set to 1.
+ It initiates saving of running configuration.
+ It will only work if there are unsaved,
+ but executed (running) changes (configuration).
+ Setting it when no new running configuration
+ is available will do nothing and return an error."
+ ::= { integraX 8 }
+
+
+-- IP settings
+
+integraXnetCfg OBJECT IDENTIFIER ::= { integraX 9 }
+
+integraXnetCfgIPaddress OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Local IP address"
+ ::= { integraXnetCfg 1 }
+
+integraXnetCfgIPmask OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Local IP mask"
+ ::= { integraXnetCfg 2 }
+
+integraXnetCfgIPgateway OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "IP gateway
+ Send '0' or '255.255.255.255' to clear."
+ ::= { integraXnetCfg 3 }
+
+integraXnetCfgRemoteIPaddress OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Remote IP address"
+ ::= { integraXnetCfg 4 }
+
+
+-- Conformance
+
+integraXConformance OBJECT IDENTIFIER ::= { integraX 10 }
+integraXCompliances OBJECT IDENTIFIER ::= { integraXConformance 1 }
+
+integraXCompliance MODULE-COMPLIANCE
+ STATUS current
+ DESCRIPTION "The compliance statement for SNMP engine which
+ implements the SAF Tehnika Integra-X device."
+ MODULE -- this module
+ MANDATORY-GROUPS {
+ integraXMiscGroup,
+ integraXRadioGroup,
+ integraXModemGroup,
+ integraXSystemGroup,
+ integraXEthernetGeneralGroup,
+ integraXEthernetMiiPortGroup }
+ ::= { integraXCompliances 1 }
+integraXGroups OBJECT IDENTIFIER ::= { integraXConformance 2 }
+
+integraXMiscGroup OBJECT-GROUP
+ OBJECTS {
+ integraXtimestamp
+ }
+ STATUS current
+ DESCRIPTION "misc data"
+ ::= { integraXGroups 1 }
+
+integraXRadioGroup OBJECT-GROUP
+ OBJECTS {
+ integraXradioAtxPower,
+ integraXradioAtxFrequency,
+ integraXradioArxLevel,
+ integraXradioArxLevelState,
+ integraXradioAside,
+ integraXradioAtxMute,
+ integraXradioAtxMuteDuration,
+ integraXradioAduplexShift,
+ integraXradioArxFrequency,
+ integraXradioAtemperature,
+ integraXradioApll,
+ integraXradioArangeEntryIndex,
+ integraXradioArangeDescr,
+ integraXradioArangeTxPower,
+ integraXradioArangeTxFrequency,
+ integraXradioBtxPower,
+ integraXradioBtxFrequency,
+ integraXradioBrxLevel,
+ integraXradioBrxLevelState,
+ integraXradioBside,
+ integraXradioBtxMute,
+ integraXradioBtxMuteDuration,
+ integraXradioBduplexShift,
+ integraXradioBrxFrequency,
+ integraXradioBtemperature,
+ integraXradioBpll,
+ integraXradioBrangeEntryIndex,
+ integraXradioBrangeDescr,
+ integraXradioBrangeTxPower,
+ integraXradioBrangeTxFrequency
+ }
+ STATUS current
+ DESCRIPTION "Radio group."
+ ::= { integraXGroups 2 }
+
+integraXModemGroup OBJECT-GROUP
+ OBJECTS {
+ integraXmodemAacquireStatus,
+ integraXmodemAnormalizedMse,
+ integraXmodemAfecLoad,
+ integraXmodemAxpdEst,
+ integraXmodemAacquireLastStatusDetails,
+ integraXmodemAtemperature,
+ integraXmodemArxModulation,
+ integraXmodemAtxModulation,
+ integraXmodemArxCapacity,
+ integraXmodemAtxCapacity,
+ integraXmodemAacmEngine,
+ integraXmodemAcarrierOffset,
+ integraXmodemAcountTime,
+ integraXmodemAerroredBlock,
+ integraXmodemAerroredSecond,
+ integraXmodemAseverelyErroredSecond,
+ integraXmodemAbackgroundBlockError,
+ integraXmodemAtotalBlockNumber,
+ integraXmodemAerroredSecondRatio,
+ integraXmodemAseverelyErroredSecondRatio,
+ integraXmodemAbackgroundBlockErrorRatio,
+ integraXmodemAuptime,
+ integraXmodemAunavailtime,
+ integraXmodemAfecLdpcBlockCounter,
+ integraXmodemAfecLdpcUncorrectedBlockCounter,
+ integraXmodemAfecLdpcUncorrectedPercent,
+ integraXmodemAfecRsBlockCounter,
+ integraXmodemAfecRsUncorrectedBlockCounter,
+ integraXmodemBacquireStatus,
+ integraXmodemBnormalizedMse,
+ integraXmodemBfecLoad,
+ integraXmodemBxpdEst,
+ integraXmodemBacquireLastStatusDetails,
+ integraXmodemBtemperature,
+ integraXmodemBrxModulation,
+ integraXmodemBtxModulation,
+ integraXmodemBrxCapacity,
+ integraXmodemBtxCapacity,
+ integraXmodemBacmEngine,
+ integraXmodemBcarrierOffset,
+ integraXmodemBcountTime,
+ integraXmodemBerroredBlock,
+ integraXmodemBerroredSecond,
+ integraXmodemBseverelyErroredSecond,
+ integraXmodemBbackgroundBlockError,
+ integraXmodemBtotalBlockNumber,
+ integraXmodemBerroredSecondRatio,
+ integraXmodemBseverelyErroredSecondRatio,
+ integraXmodemBbackgroundBlockErrorRatio,
+ integraXmodemBuptime,
+ integraXmodemBunavailtime,
+ integraXmodemBfecLdpcBlockCounter,
+ integraXmodemBfecLdpcUncorrectedBlockCounter,
+ integraXmodemBfecLdpcUncorrectedPercent,
+ integraXmodemBfecRsBlockCounter,
+ integraXmodemBfecRsUncorrectedBlockCounter,
+ integraXmodemBandwidth,
+ integraXmodemModulation,
+ integraXmodemAmodulationACMmin,
+ integraXmodemAmodulationACMmax,
+ integraXmodemBmodulationACMmin,
+ integraXmodemBmodulationACMmax
+ }
+ STATUS current
+ DESCRIPTION "Modem group."
+ ::= { integraXGroups 3 }
+
+integraXSystemGroup OBJECT-GROUP
+ OBJECTS {
+ integraXsysCPUtemperature,
+ integraXsysLicenseExpire,
+ integraXsysLicenseGenStatus,
+ integraXsysPSUvoltage,
+ integraXsysPSUcurrent,
+ integraXsysPSUpower,
+ integraXsysBoardTemperature,
+ integraXsysFreeMemory,
+ integraXsysCPUidle,
+ integraXsysDeviceType,
+ integraXsysDeviceSerial,
+ integraXsysDeviceProductModel,
+ integraXsysFanError,
+ integraXexecuteConfig,
+ integraXneedStore,
+ integraXstoreConfig,
+ integraXsysSw1v0core,
+ integraXsysSw1v0avdd,
+ integraXsysSw1v2a,
+ integraXsysSw1v5ddr,
+ integraXsysSw1v8,
+ integraXsysSw2v5,
+ integraXsysSw3v3,
+ integraXsysVttrefPs,
+ integraXsysVttddrPs,
+ integraXsysZq1v0,
+ integraXsysZq1v5,
+ integraXsysZq1v8,
+ integraXsysZq2v5,
+ integraXsysZq3v3,
+ integraXsys5v0d,
+ integraXsysSw1v2,
+ integraXsysMdmVddcAvs,
+ integraXsysMdm3v3,
+ integraXsysMdm1v0aPm,
+ integraXsysMdm1v0a,
+ integraXsysMdm1v8a,
+ integraXsysMdmDAC02v5a,
+ integraXsysMdmDAC12v5,
+ integraXsysMdmDAC22v5,
+ integraXsysMdm1v8io,
+ integraXsysMdm3v3io,
+ integraXsys3v3Radio,
+ integraXsysMdm4v0,
+ integraXsys5v0nRadio,
+ integraXsysCoreVddSns,
+ integraXsys40v0RadioSns,
+ integraXsysServicesReboot,
+ integraXsysServicesFtpSwitch,
+ integraXsysServicesFwCurrInfo,
+ integraXsysServicesFwAvailView,
+ integraXsysServicesFwRemove,
+ integraXsysServicesFwRemoveAll,
+ integraXsysServicesFwUpload,
+ integraXsysServicesFwInst,
+ integraXsysServicesFwSwitchRunning,
+ integraXsysServicesFwSwitchNext
+ }
+ STATUS current
+ DESCRIPTION "System group."
+ ::= { integraXGroups 4 }
+
+integraXEthernetGeneralGroup OBJECT-GROUP
+ OBJECTS {
+ integraXifPortStatIndex,
+ integraXifPortStatDescr,
+ integraXifPortType,
+ integraXifPortMtu,
+ integraXifPortHighSpeed,
+ integraXifPortPhysAddress,
+ integraXifPortAdminStatus,
+ integraXifPortOperStatus,
+ integraXifPortLastChange,
+ integraXifPortAutoneg,
+ integraXifPortDuplex,
+ integraXifPortSyncEthActive,
+ integraXifPortSyncEthPrio,
+ integraXifPortFlowControl,
+ integraXifPortStcIndex,
+ integraXifPortStcDescr,
+ integraXifTimePassed,
+ integraXifIngressPackets,
+ integraXifIngressBytes,
+ integraXifEgressPackets,
+ integraXifEgressBytes,
+ integraXifEtherRxOversizePkts,
+ integraXifEtherTxOversizePkts,
+ integraXifReceivedPkts64Octets,
+ integraXifTransmittedPkts64Octets,
+ integraXifReceivedPkts65to127Octets,
+ integraXifTransmittedPkts65to127Octets,
+ integraXifReceivedPkts128to255Octets,
+ integraXifTransmittedPkts128to255Octets,
+ integraXifReceivedPkts256to511Octets,
+ integraXifTransmittedPkts256to511Octets,
+ integraXifReceivedPkts512to1023Octets,
+ integraXifTransmittedPkts512to1023Octets,
+ integraXifReceivedPkts1024to1518Octets,
+ integraXifTransmittedPkts1024to1518Octets,
+ integraXifIfInBroadcastPkts,
+ integraXifIfOutBroadcastPkts,
+ integraXifIfInMulticastPkts,
+ integraXifIfOutMulticastPkts,
+ integraXifIngressBPS,
+ integraXifIngressPPS,
+ integraXifEgressBPS,
+ integraXifEgressPPS,
+ integraXifAllCoSQoutPackets,
+ integraXifAllCoSQoutBytes,
+ integraXifAllCoSQdroppedPackets,
+ integraXifAllCoSQdroppedBytes,
+ integraXifProcessedRxPackets,
+ integraXifProcessedRxBytes,
+ integraXnetCfgIPaddress,
+ integraXnetCfgIPmask,
+ integraXnetCfgIPgateway,
+ integraXnetCfgRemoteIPaddress,
+ integraXifLspPortAdminState,
+ integraXifLspPortList,
+ integraXifLspPortStatus
+ }
+ STATUS current
+ DESCRIPTION "A collection to objects, providing info applicable to
+ all network interfaces."
+ ::= { integraXGroups 5 }
+
+integraXEthernetMiiPortGroup OBJECT-GROUP
+ OBJECTS {
+ integraXifEtherStatsMulticastPkts,
+ integraXifEtherStatsBroadcastPkts,
+ integraXifEtherStatsPkts64Octets,
+ integraXifEtherStatsPkts65to127Octets,
+ integraXifEtherStatsPkts128to255Octets,
+ integraXifEtherStatsPkts256to511Octets,
+ integraXifEtherStatsPkts512to1023Octets,
+ integraXifEtherStatsPkts1024to1518Octets,
+ integraXifEtherStatsOversizePkts,
+ integraXifEtherStatsOctets,
+ integraXifEtherStatsPkts,
+ integraXifEtherStatsTXNoErrors,
+ integraXifEtherStatsRXNoErrors,
+ integraXifEtherStatsPkts1519to1522Octets,
+ integraXifIfInOctets,
+ integraXifIfOutOctets,
+ integraXifDot1dTpPortInFrames,
+ integraXifDot1dTpPortOutFrames,
+ integraXifDot3InPauseFrames,
+ integraXifDot3OutPauseFrames,
+ integraXifEtherStatsUndersizePkts,
+ integraXifEtherStatsFragments,
+ integraXifEtherStatsCRCAlignErrors,
+ integraXifEtherStatsJabbers
+ }
+ STATUS current
+ DESCRIPTION "A collection of objects, providing info applicable
+ only to MII group interfaces."
+ ::= { integraXGroups 6 }
+
+
+END