diff options
| author | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
|---|---|---|
| committer | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
| commit | 98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch) | |
| tree | 9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/sagemcom/EQUIPMENT-MIB | |
| download | mibs-main.tar.gz mibs-main.zip | |
Diffstat (limited to 'MIBS/sagemcom/EQUIPMENT-MIB')
| -rw-r--r-- | MIBS/sagemcom/EQUIPMENT-MIB | 886 |
1 files changed, 886 insertions, 0 deletions
diff --git a/MIBS/sagemcom/EQUIPMENT-MIB b/MIBS/sagemcom/EQUIPMENT-MIB new file mode 100644 index 0000000..9d46bdd --- /dev/null +++ b/MIBS/sagemcom/EQUIPMENT-MIB @@ -0,0 +1,886 @@ +--*******************************************************************
+--* SAGEM, IONOS *
+--*******************************************************************
+--*******************************************************************
+--
+-- Filename: equip
+--
+-- File type: .mib
+--
+-- Description: SNMP source Mib file.
+--
+-- Contains general description and operation for
+-- equipent level.
+--
+--
+-- Version: 19 11 2002
+--
+-- Date(DD MM YYYY): 15 11 2002 last update for IONOS NMS
+--
+-- Contact: D. Mobuchon, F. Bonnevialle
+--
+-- History:
+-- Version: Date: 04 08 98
+-- Version: MIB-P0-301199 Date: 30 11 1999
+-- Version: MIB-P0-05092000 Date: 05 09 2000
+-- Modification de la table des managers
+--
+-- Name: S.LAURENT
+-- Date: 25 04 2001
+-- Desc: * Add 7 equipment modification counters
+--
+-- Name: S.LAURENT
+-- Date: 14 06 2002
+-- Desc: * DisplayString is imported from SNMPv2-TC instead of RFC1213
+--
+-- Name: F.Bonnevialle
+-- Date: 15 11 2002
+-- Desc: Modification for SilverCreek Compiler
+--*******************************************************************
+--*******************************************************************
+--* Copyright (c) 2002, SAGEM , All rights reserved. *
+--*******************************************************************
+
+
+
+
+--*******************************************************************
+-- MIB: EQUIPMENT-MIB
+--*******************************************************************
+EQUIPMENT-MIB DEFINITIONS ::= BEGIN
+
+
+--*******************************************************************
+-- IMPORTS
+--*******************************************************************
+
+ IMPORTS
+ sagemDr FROM SAGEM-DR-MIB
+ MODULE-IDENTITY,
+ OBJECT-TYPE,
+ NOTIFICATION-TYPE,
+ IpAddress,Counter32 FROM SNMPv2-SMI
+ DisplayString FROM SNMPv2-TC;
+-- TRAP-TYPE FROM RFC-1215;
+
+
+
+
+--*******************************************************************
+-- OBJECTS
+--*******************************************************************
+
+--*******************************************************************
+
+ equip MODULE-IDENTITY
+ LAST-UPDATED "0211150000Z"
+ ORGANIZATION "SAGEM/DR Tolbiac Centre"
+ CONTACT-INFO " "
+ DESCRIPTION
+ "
+ Modification:
+ Date: 15 11 2002
+ Description:
+ sagemDr replace sagem-dr
+ NOTIFICATION-TYPE replace TRAP-TYPE
+
+ Modification:
+ Date: 14 06 2002
+ Description: Modification of Imports
+ DisplayString is imported from SNMPv2-TC instead of RFC1213
+
+ Modification:
+ Date: 20 12 1999
+ Description: Modification of comments
+ Modification of bugs
+
+ Modification:
+ Date: 19 11 1999
+ Name: sagem-dr, SagemBoolean
+ Description: Definition of OID sagem-dr instead of sat
+ Definition of data SagemBoolean instead of Boolean
+
+ Name: communityString
+ Description: SIZE(0..20) replaced by SIZE (0..50)
+
+
+ New Object:
+ Date: 19 11 1999
+
+ Name: All *Manager* are new objects
+ Description: Manager list that recieves the traps.
+
+ Name: equipCptModif
+ Description: Incremental counter used to manage
+ the modifications on the equipment.
+
+ Name: communityAcces
+ Description: new names used
+ iONNOS-ANM-Supervisor instead of Set ...
+
+ Name: trapCommunity
+ Description:SIZE(0..20) replaced by SIZE (0..50)
+
+ Name: equipLoad
+ Description: Object is simplified to an OID
+
+ Name: equipLoadDiagnostic
+ Description: A string to help in case of problem
+
+ Name: transferedItemTable,transferedItem,
+ TransferedItem,transferedItemIndex
+ transferedItemType,transferedItemVersion
+ transferedItemComments
+ Description:
+ These object are used to manage the download
+ and upload of some part of the data; the data
+ can be a part of a program, a complete program,
+ or a config.
+ The transferedItemType is reused in equipLocalFile
+
+ Name: equipStatusV2
+ Description: used by IONOS ANM V2
+
+ "
+ REVISION "9808040000Z"
+ DESCRIPTION
+ "
+ Creation : this MIB module describes equipment level operation such as
+ date and time set, restart, reset, community and trap
+ management.
+ "
+ ::= { sagemDr 107 }
+
+--*******************************************************************
+
+SagemBoolean ::= INTEGER { true(1), false(2) }
+IntDateTime ::= INTEGER (0..2147483647)
+Severity ::= INTEGER
+ {
+ nonAlarmed (1),
+ minor (2),
+ major (3),
+ critical (4),
+ warning (5),
+ invNonAlarmed (6),
+ invMinor(7),
+ invMajor(8),
+ invCritical(9),
+ invWarning(10)
+ }
+
+
+--*******************************************************************
+ equipDateTime OBJECT-TYPE
+ SYNTAX IntDateTime
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The value of this field is the date and time of the equipment.
+ It is the number of seconds since 1st January 1970."
+ ::= { equip 1 }
+
+ equipLastModif OBJECT-TYPE
+ SYNTAX IntDateTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The date and time when the equipment was last modified."
+ ::= { equip 2 }
+
+ equipWarmStart OBJECT-TYPE
+ SYNTAX SagemBoolean
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The equipment make a hot start if this field is set to `true'.
+ This operation can only be done by the iONOSANMsupervisor
+ or dIRECTACCESSsupervisor.
+ The value returns to `false' after the restart."
+ ::= { equip 3 }
+
+ equipClearConf OBJECT-TYPE
+ SYNTAX SagemBoolean
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The equipment resets all its parameters, including those
+ stored in non-volatile media storage, if this field is set
+ to `true'.
+ This command does not apply to mib-2 parameters, like @ip,
+ routing table, etc ...
+ This operation can only be done by the iONOSANMsupervisor
+ or dIRECTACCESSsupervisor.
+ The value returns to `false' after the reset.
+ This operation is optionnal."
+ ::= { equip 4 }
+
+
+--*******************************************************************
+-- Description:
+-- Community
+-- The "communityTable" is used for the habilitation.
+-- It contains a sequense of "CommunityEntry"
+-- The size for the habilitation table is 10 elements for ADR equipement.
+-- A "CommunityEntry" is a sequence:
+-- (communityIndex,communityString,communityAccess)
+-- The different kind of habilitation are:
+-- iONOSANMobserver,
+-- iONOSANMoperator,
+-- iONOSANMsupervisor,
+-- dIRECTACCESSobserver,
+-- dIRECTACCESSoperator,
+-- dIRECTACCESSsupervisor,
+-- The 4 last one are used for the "Add Drop for IP" IPA.
+-- iONOSANMclientobserver,
+-- iONOSANMclientoperator,
+-- dIRECTACCESSclientobserver,
+-- dIRECTACCESSclientoperator.
+
+ communityNumber OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of community in equipment."
+ ::= { equip 5 }
+
+ communityTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CommunityEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "List of community in equipment."
+ ::= { equip 6 }
+
+ communityEntry OBJECT-TYPE
+ SYNTAX CommunityEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A particular community of the equipment."
+ INDEX { communityIndex }
+ ::= { communityTable 1 }
+
+ CommunityEntry ::=
+ SEQUENCE {
+ communityIndex INTEGER,
+ communityString DisplayString,
+ communityAcces INTEGER
+ }
+
+ communityIndex OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A unique value which identify a particular
+ community."
+ ::= { communityEntry 1 }
+
+
+ communityString OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A unique textual string that can be used by a SNMP manager as
+ community string. It can be also used as password for other
+ configuration like http, not only snmp.
+ The table must have at least two entries associated with
+ the iONOSANMsupervisor access right (this entry is created by
+ equipement at startup with value `secret') and
+ dIRECTACCESSsupervisor access right (this entry is
+ created by equipement at startup with value 'supervisor') .
+ According to equipment implementation, it is possible to
+ create other entries associed with lower rights that PDU
+ community string can afford (actualy equal if
+ IONOSANMsupervisor status is granted).
+ If the other access rights are created at startup by the equipment,
+ its must use the following values : 'private' for
+ 'iONOSANMoperator, 'public' for 'iONOSANMobserver',
+ 'operator' for dIRECTACCESSoperator, 'observer' for
+ dIRECTACCESSobserver, and 'client' for the others.
+
+ All community string can be modified only by
+ IONOSANMsupervisor.
+ A dIRECTACCESS community string can be modified by
+ dIRECTACCESSsupervisor.
+
+ The reading of a community string gives *** for all
+ access rights .
+
+ An entry may be discarded by setting its community string to
+ void string. This should not be used by the administrator or
+ he could discard himself "
+
+ ::= { communityEntry 2 }
+
+
+ communityAcces OBJECT-TYPE
+ SYNTAX INTEGER {iONOSANMobserver (1),
+ iONOSANMoperator(2),
+ iONOSANMsupervisor(3),
+ dIRECTACCESSobserver (4),
+ dIRECTACCESSoperator(5),
+ dIRECTACCESSsupervisor(6),
+ iONOSANMclientobserver(7),
+ iONOSANMclientoperator(8),
+ dIRECTACCESSclientobserver(9),
+ dIRECTACCESSclientoperator(10)
+ }
+
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "
+ iONOSANMsupervisor(3) access :
+ allows all operations including community string
+ (community string = password)
+ iONOSANMoperator(2) access :
+ allows all set operations except write community
+ string read or write and also some special operations.
+ iONOSANMobserver (1) access :
+ allows only get and get_next requests.
+ dIRECTACCESSsupervisor(6) access :
+ allows all operations EXcluding IONOS ANM community string
+ dIRECTACCESSoperator(5) access :
+ allows all set operations except write community
+ string read or write and also some special operations.
+ dIRECTACCESSobserver (4) access :
+ allows only get and get_next requests.
+ iONOSANMclientoperator(8) access :
+ allows only set some special operations
+ iONOSANMclientobserver(7) access :
+ allows only get and get_next requests for special operations
+ dIRECTACCESSclientoperator(10) access :
+ allows only set some special operations
+ dIRECTACCESSclientobserver(9) access :
+ allows only get and get_next requests for special operations
+ "
+ ::= { communityEntry 3 }
+
+
+--*******************************************************************
+-- Description:
+-- "trapTable": trap's receiver table
+
+ trapNumber OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of trap receivers description in equipment."
+ ::= { equip 7 }
+
+ trapTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TrapEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "List of trap receivers in equipment."
+ ::= { equip 8 }
+
+ trapEntry OBJECT-TYPE
+ SYNTAX TrapEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A particular trap of the equipment."
+ INDEX { trapIndex }
+ ::= { trapTable 1 }
+
+ TrapEntry ::=
+ SEQUENCE {
+ trapIndex INTEGER,
+ trapDestination IpAddress,
+ trapCommunity DisplayString
+ }
+
+ trapIndex OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A unique value which identify a particular
+ trap receiver.
+ The value of index is a constant assigned to an entry at
+ equipment design time. "
+ ::= { trapEntry 1 }
+
+ trapDestination OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The ip address to which the equipment will send the traps.
+ Note that the value must be unique along this table.
+ An entry may be discarded by setting the IP address to 0.0.0.0
+ "
+ ::= { trapEntry 2 }
+
+
+ trapCommunity OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+-- It is better to use a size value lower than 10.
+-- The size value 50 is used for the BMX
+ "The community string to use when a trap is sent to
+ this address. "
+ ::= { trapEntry 3 }
+
+
+
+--*******************************************************************
+
+-- Description:
+-- Up and download for the software and configuration
+--
+ equipLoad OBJECT IDENTIFIER ::= { equip 9 }
+
+ equipLocalFile OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The file path suitable for the equipment."
+ ::= { equipLoad 1 }
+
+ equipServerAddress OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The ip adress of tftp serveur from which is read/write
+ the file `equipRemoteFile'."
+ ::= { equipLoad 2 }
+
+ equipRemoteFile OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The file path to be loaded on/from the equipement."
+ ::= { equipLoad 3 }
+
+ equipDirection OBJECT-TYPE
+ SYNTAX INTEGER { download (0), upload(1)
+ , backupDownload (2), switching (3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This field selects the direction of data stream.
+ When it is set to `backupDownload', only the transfert is done.
+ When it is set to `download' the transfert is done and then the
+ information transfert is switched in the operational state.
+ When it is set to `switching', there is no transfert;
+ there is only a switching. "
+ ::= { equipLoad 4 }
+
+ equipLoadProceed OBJECT-TYPE
+ SYNTAX SagemBoolean
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "
+ This entry is use to start (set to `true') loading a file
+ on/from a equipment which has a tftp client.
+ The value of the field remains to `true' until load is
+ completed or has been aborted.
+ This operation can only be done by the iONOSANMsupervisor
+ or dIRECTACCESSsupervisor.
+ It may be possible to abort the loading by setting it
+ to false.
+ After the switching of a new configuration, the equipment
+ must increase the value of the variable 'equipCptModif'
+ "
+ ::= { equipLoad 5 }
+
+ equipLoadDiagnostic OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A string used to help in case of trouble."
+ ::= { equipLoad 6 }
+
+ equipLoadProtocole OBJECT-TYPE
+ SYNTAX INTEGER { ftp (1), tftp (2),
+ http (3), telnet (4)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Protocole used by the equipment for the download"
+ ::= { equipLoad 7 }
+
+
+--*******************************************************************
+-- Description:
+-- Delayed up and download for the software and configuration
+--
+-- equipLoadState OBJECT-TYPE
+-- SYNTAX INTEGER { delayedLoad (1), loadRunning (2),
+-- delayedSwitching (3), switchingRunning (4),
+-- loadOK (5), loadNOK (6) ,aborted (7)}
+-- MAX-ACCESS read-only
+-- STATUS current
+-- DESCRIPTION
+-- "This field indicates the status of the current load processes valided
+-- by 'equipLoadProceed'.
+-- Remark : a download includes a data transfer (load) from the
+-- server to the equipment and a switching for using the data or the
+-- software transfered . A upload includes only a data transfer from
+-- the equipment to the server
+-- It's optional for the equipment which doesn't realise delayed download "
+-- ::= { equipLoad 8 }
+--
+-- equipLoadDateTime OBJECT-TYPE
+-- SYNTAX IntDateTime
+-- MAX-ACCESS read-write
+-- STATUS current
+-- DESCRIPTION
+-- "The value of this field is the date and time of the equipment
+-- at which the load processes valided by
+-- 'equipLoadProceed' must begin .
+-- If this value if equal at 0 or < at the current
+-- time, the load starts immediately.
+-- It is the number of seconds since 1st January 1970."
+-- ::= { equipLoad 9 }
+--
+-- equipSwitchingDateTime OBJECT-TYPE
+-- SYNTAX IntDateTime
+-- MAX-ACCESS read-write
+-- STATUS current
+-- DESCRIPTION
+-- "
+-- The value of this field is the date and time of the equipment
+-- at which the switching processes valided by
+-- 'equipLoadProceed' must begin .If this value if equal at
+-- 0 or < at the current time, the switching starts immediately
+-- (if there isn't load)or immediately after the load (if there is a load).
+-- It is the number of seconds since 1st January 1970.
+-- After the switching of a new configuration, the equipment
+-- must increase the value of the variable 'equipCptModif'
+-- "
+-- ::= { equipLoad 10 }
+--
+
+
+--*******************************************************************
+-- Description:
+-- These object are used to manage the download
+-- and upload of some part of the data; the data
+-- can be a part of a program, a complete program,
+-- or a config.
+--
+-- The transferedItemType can be:
+-- inactive programName
+-- active programName
+-- inactive"Config"
+-- active"Config"
+-- ALL Program
+-- ALL
+--
+-- The transferedItemType is reused in equipLocalFile
+
+
+ transferedItemTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TransferedItemEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "List of uploaded or downloaded Item from the
+ equipment."
+ ::= { equip 30 }
+
+ transferedItemEntry OBJECT-TYPE
+ SYNTAX TransferedItemEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A particular Item transferd from/to the equipment."
+ INDEX { transferedItemIndex }
+ ::= { transferedItemTable 1 }
+
+ TransferedItemEntry ::=
+ SEQUENCE {
+ transferedItemIndex INTEGER,
+ transferedItemType DisplayString,
+ transferedItemVersion DisplayString,
+ transferedItemComment DisplayString
+ }
+
+ transferedItemIndex OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ ""
+ ::= { transferedItemEntry 1 }
+
+ transferedItemType OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "used to know what kind of data to transferate,
+ mainly programName or config"
+ ::= { transferedItemEntry 2 }
+
+ transferedItemVersion OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "for a program, return the software version;
+ for a config return the associated software version"
+ ::= { transferedItemEntry 3 }
+
+ transferedItemComment OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "give additional information about the tranfered data"
+ ::= { transferedItemEntry 4 }
+
+--*******************************************************************
+-- Description:
+
+ equipStatus OBJECT-TYPE
+ SYNTAX Severity
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This field summerizes the status of all equipment objects
+ (port, card, ...)
+ This variable is polled by IONOS ANM V1
+ The 'equipmentStatusTrap' is sent after a GET on this variable.
+ equipStatus and equipStatusTrap are only used with V1.
+ "
+ ::= { equip 10 }
+
+ equipStatusV2 OBJECT-TYPE
+ SYNTAX Severity
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Replace equipStatus for the v2. For the v1, equipStatus
+ in EQUIPMENT-MIB send a trap after been polled;
+ For the v2, equipStatus is polled."
+ ::= { equip 11 }
+
+--*******************************************************************
+--* modification counters
+--*******************************************************************
+-- Description:
+-- "equipCptModif":
+-- Incremental counter used to manage the modifications
+-- on the equipment.
+-- Warning:
+-- Replace equipLastModif for the new equipment ADR155c and
+-- the next generation of equipment.
+
+ equipCptModif OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The counter for all equipments modifications. It represents
+ the sum of the 7 other counters"
+ ::= { equip 12 }
+
+ -- Modification counters
+ cptModif OBJECT IDENTIFIER ::= { equip 14 }
+
+ cptSNC OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The counter version for the SNC modifications."
+ ::= { cptModif 1 }
+
+
+ cptCnx OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The counter version for the Connexion modifications."
+ ::= { cptModif 2 }
+
+ cptMSP OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The counter version for the MSP modifications."
+ ::= { cptModif 3 }
+
+ cptMsSpring OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The counter version for the MS-SPRING modifications."
+ ::= { cptModif 4 }
+
+ cptSynchro OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The counter version for the Synchro modifications."
+ ::= { cptModif 5 }
+
+ cptMngt OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The counter version for the MNGT modifications (mngt list, password, trap, ...)."
+ ::= { cptModif 6 }
+
+ cptNet OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The counter version for the Network modifications."
+ ::= { cptModif 7 }
+
+
+-- equipConfSaveStatus OBJECT-TYPE
+-- SYNTAX SagemBoolean
+-- MAX-ACCESS read-only
+-- STATUS current
+-- DESCRIPTION
+-- "If 'true', this variable indicates that all configuration
+-- modifications are saved in flash memory.
+-- If false, this variable indicates that configuration
+-- modifications are not saved in flash memory. "
+-- ::= { equip 13 }
+
+
+--*******************************************************************
+--
+-- Description:
+-- ACCESS TABLE FILTER
+-- The table is a access filter table that ckeck the IP address of
+-- the SNMP managers.
+
+
+ equipManagerNumber OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of manager = number of IP addresses in the table"
+ ::= { equip 20 }
+
+ equipManagerTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EquipManagerEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table containing Ip Addresses and maximum authorized level"
+ ::= { equip 21 }
+
+ equipManagerEntry OBJECT-TYPE
+ SYNTAX EquipManagerEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry containing IP addresses of managers allowed in R/W."
+ INDEX {equipManagerIndex}
+ ::= {equipManagerTable 1}
+
+ EquipManagerEntry ::=
+ SEQUENCE
+ {
+ equipManagerIndex INTEGER,
+ equipManagerAddress IpAddress,
+ equipManagerADM SagemBoolean,
+ equipManagerOPR SagemBoolean,
+ equipManagerOBS SagemBoolean
+ }
+
+ equipManagerIndex OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index of equipManagerTable
+ There's only 10 values in this table"
+ ::= {equipManagerEntry 1}
+
+ equipManagerAddress OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The IP address of one of the allowed managers.
+ If the table contains only address values which are equal
+ to 0.0.0.0, no access filter are done.
+ Write the IP address 0.0.0.0 to remove a manager.
+ This operation can only be done by the iONOSANMsupervisor.
+ "
+ ::= {equipManagerEntry 2}
+
+ equipManagerADM OBJECT-TYPE
+ SYNTAX SagemBoolean
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "If 'true', this variable indicates that the manager defined by
+ its address can have the Supervisor rigth as maximum level
+ The value 'false' is set by the equipment when another level
+ is choosen"
+ ::= {equipManagerEntry 3}
+
+ equipManagerOPR OBJECT-TYPE
+ SYNTAX SagemBoolean
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "If 'true', this variable indicates that the manager defined by
+ its address can have the Operator rigth as maximum level
+ The value 'false' is set by the equipment when another level
+ is choosen"
+ ::= {equipManagerEntry 4}
+
+ equipManagerOBS OBJECT-TYPE
+ SYNTAX SagemBoolean
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "If 'true', this variable indicates that the manager defined by
+ its address can have the Observer rigth as maximum level
+ The value 'false' is set by the equipment when another level
+ is choosen"
+ ::= {equipManagerEntry 5}
+
+--*******************************************************************
+-- Warning: This Trap is only used for V1
+-- equipStatusTrap TRAP-TYPE
+-- ENTERPRISE equip
+-- VARIABLES { equipStatus }
+-- DESCRIPTION
+-- "This trap indicates the alarm status of the equipment.
+-- Only sent with IONOS ANM V1"
+-- ::= 1
+
+ equipTraps OBJECT IDENTIFIER ::= { equip 0 }
+
+ equipStatusTrap NOTIFICATION-TYPE
+ OBJECTS { equipStatus }
+ STATUS current
+ DESCRIPTION "This trap indicates the alarm status of the equipment.
+ Only sent with IONOS ANM V1"
+ REFERENCE ""
+ ::= { equipTraps 1 }
+END
|