diff options
| author | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
|---|---|---|
| committer | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
| commit | 98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch) | |
| tree | 9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/sagemcom/SDH-ETS-MIB | |
| download | mibs-main.tar.gz mibs-main.zip | |
Diffstat (limited to 'MIBS/sagemcom/SDH-ETS-MIB')
| -rw-r--r-- | MIBS/sagemcom/SDH-ETS-MIB | 2923 |
1 files changed, 2923 insertions, 0 deletions
diff --git a/MIBS/sagemcom/SDH-ETS-MIB b/MIBS/sagemcom/SDH-ETS-MIB new file mode 100644 index 0000000..6012b0c --- /dev/null +++ b/MIBS/sagemcom/SDH-ETS-MIB @@ -0,0 +1,2923 @@ +--*******************************************************************
+--* SAGEM SA *
+--*******************************************************************
+--*******************************************************************
+
+-- Filename: sdh-ETS
+-- File type: .mib
+--
+-- Description: SNMPc source Mib file.
+-- The MIB module defines SDH transmition part of an equipment
+-- as it's modeled in ETSI ETS 300 304.
+--
+-- Version: 19 11 2002
+--
+-- Date(DD MM YYYY): 15 11 02 last update for IONOS NMS
+--
+-- Contact: D. Mobuchon, F. Bonnevialle
+--
+-- History:
+-- Name: F.Bonnevialle
+-- Date: 12 12 2000
+-- Desc: original
+--
+-- Name: S.LAURENT
+-- Date: 08 02 2001
+-- Desc: The synchronization functions of this MIB are deleted
+-- and put in a new MIB SYNCHRO.
+--
+-- Name: S.LAURENT
+-- Date: 11 04 2001
+-- Desc: * Modifications in MSA, VC4 and AU4 Tables.
+--
+-- Name: S.LAURENT
+-- Date: 25 04 2001
+-- Desc: * Name Modification: ppi -> nspi (for not spi).
+-- This change allow to accept more non-sdh interfaces such
+-- as atm or Ethernet (which are not plesiochronous kind).
+-- * Size Modification of the vc4PathTrace Strings
+-- * deletion of alarme and severity fields in MsaTable.
+--
+-- Name: F.Bonnevialle
+-- Date: 30 04 2001
+-- Desc: Description modification to match with ETS-300 304
+--
+-- Name: S.LAURENT
+-- Date: 09 08 2001
+-- Desc: * Rights access modification on variables: vc12TTPSinkPointer
+-- and vc3TTPSinkPointer
+-- * TUG3 Object Deletion: This object didn't give any adding
+-- information.
+-- * Deletion of tu3CTPLom and tu12CTPLom variables
+-- * Creation of au4CTPLom Variable adding to a new value in Au4CTPFailure Type( lom(3))
+--
+-- Name: S.LAURENT
+-- Date: 30 08 2001
+-- Desc: * comments modification on Au4CTPTable variables
+-- * Add a new value 'tu(20)' in AU4CTPType
+-- * Deletion of tu3CTPLom and tu12CTPLom variables
+-- * Creation of au4CTPLom Variable adding to a new value in Au4CTPFailure Type( lom(3))
+--
+-- Name: S.LAURENT
+-- Date: 22 05 2002
+-- Desc: * Creation of ChannelTable
+-- * Creation of BandwidthTable
+-- * Add a new value 'channel(4)' in NspiSrcType
+--
+-- Name: F.Bonnevialle
+-- Date: 15 11 2002
+-- Desc: Modification for SilverCreek Compiler
+--
+--*******************************************************************
+--*******************************************************************
+--* Copyright (c) 2002, SAGEM , All rights reserved. *
+--*******************************************************************
+
+
+
+
+--*******************************************************************
+-- MIB: SDH-ETS-MIB
+--*******************************************************************
+SDH-ETS-MIB DEFINITIONS ::= BEGIN
+
+--*******************************************************************
+-- IMPORTS
+--*******************************************************************
+
+ IMPORTS
+ sagemDr FROM SAGEM-DR-MIB
+ SagemBoolean, Severity FROM EQUIPMENT-MIB
+ MODULE-IDENTITY,OBJECT-TYPE FROM SNMPv2-SMI
+ DisplayString FROM SNMPv2-TC; --RFC1213-MIB;
+
+ sdhEts MODULE-IDENTITY
+ LAST-UPDATED "0205220000Z"
+ ORGANIZATION "SAGEM-Tolbiac drd/ddp/tmhd"
+ CONTACT-INFO
+ " "
+ DESCRIPTION
+ "The MIB module defines SDH transmition part of an equipment
+ This MIB use the logical model defined in ETSI ETS 300 304.
+ ETS 300 304 (February 1997) defines the SDH information
+ model for the Network Element.
+ This MIB refers to SHELF-MIB
+ for the definition of the Board that supports the interface.
+ This MIB is refered by XCON-MIB that uses
+ the definition of termination point to create cross connection.
+ This MIB also define configuration of the different SDH blocs
+ such as alarm monitoring and severity and give the current status of
+ the termination point.
+ "
+ ::= { sagemDr 110 }
+
+
+ -- Synchronous Physical Interface Trail Termination Point
+ -- Reference to ETS 300 304:
+ -- electricalSPITTPSink, electricalSPITTPSink
+ -- opticalSPITTPSink, opticalSPITTPSink
+ spiTTP OBJECT IDENTIFIER ::= { sdhEts 10 }
+
+ -- regenerator section terminaison Trail Termination Point
+ -- Reference to ETS 300 304:
+ -- rsTTPSink, rsTTPSink
+ rsTTP OBJECT IDENTIFIER ::= { sdhEts 20 }
+
+ -- regenerator section terminaison Connection Termination Point
+ -- Reference to ETS 300 304:
+ -- rsCTPSink, rsCTPSink
+ rsCTP OBJECT IDENTIFIER ::= { sdhEts 25 }
+
+
+ -- multiplex section terminaison Trail Termination Point
+ -- Reference to ETS 300 304:
+ -- msTTPSink, msTTPSink
+ msTTP OBJECT IDENTIFIER ::= { sdhEts 30 }
+
+ -- multiplex section terminaison Connection Termination Point
+ -- Reference to ETS 300 304:
+ -- msCTPSink, msCTPSink
+ msCTP OBJECT IDENTIFIER ::= { sdhEts 35 }
+
+ -- multiplex section adaptation
+ msa OBJECT IDENTIFIER ::= { sdhEts 60 }
+
+ -- administrative unit order 4 Connection Termination Point
+ -- Reference to ETS 300 304:
+ -- au4CTPSink, au4CTPSink
+ au4CTP OBJECT IDENTIFIER ::= { sdhEts 70 }
+
+ -- virtual container order 4 Trail Termination Point
+ -- Reference to ETS 300 304:
+ -- vc4TTPSink, vc4TPSink
+ vc4TTP OBJECT IDENTIFIER ::= { sdhEts 100 }
+
+ -- tributary unit order 3 Connection Termination Point
+ -- Reference to ETS 300 304:
+ -- tu3CTPSink, tu3CTPSink
+ tu3CTP OBJECT IDENTIFIER ::= { sdhEts 120 }
+
+ -- virtual container order 3 Trail Termination Point
+ -- Reference to ETS 300 304:
+ -- vc3TTPSink, vc3TTPSink
+ vc3TTP OBJECT IDENTIFIER ::= { sdhEts 130 }
+
+ -- tributary unit order 12 Connection Termination Point
+ -- Reference to ETS 300 304:
+ -- tu12CTPSink, tu12CTPSink
+ tu12CTP OBJECT IDENTIFIER ::= { sdhEts 140 }
+
+ -- virtual container order 12 Trail Termination Point
+ -- Reference to ETS 300 304:
+ -- vc12CTPSink, vc12CTPSink
+ vc12TTP OBJECT IDENTIFIER ::= { sdhEts 150 }
+
+ -- non sdh Connection termination point Connection Termination Point
+ -- Reference to ETS 300 304:
+ -- p12CTPSink, p12CTPSink, p31CTPSink, p31CTPSink, ...
+ -- for PDH terminaison.
+ -- The object (table/type) can be updated to match other kind of
+ -- non SDH terminaison such as Ethernet or ATM interface over SDH
+ nspiCTP OBJECT IDENTIFIER ::= { sdhEts 160 }
+
+ -- non sdh physical port Trail Termination Point
+ -- Reference to ETS 300 304:
+ -- p12TTPSink, p12TTPSink, p31TTPSink, p31TTPSink, ...
+ -- for PDH terminaison.
+ -- The object (table/type) can be updated to match other kind of
+ -- non SDH terminaison such as Ethernet or ATM interface over SDH
+ nspiTTP OBJECT IDENTIFIER ::= { sdhEts 170 }
+
+ -- Channel Layer
+ channel OBJECT IDENTIFIER ::= { sdhEts 180 }
+
+ -- Non sdh adaptation layer: Bandwidth
+ bandwidth OBJECT IDENTIFIER ::= { sdhEts 190 }
+
+
+
+-- Note on the srcPointer ans sinkPointer
+-- The transmission functions and interfaces include a set of integer named
+-- "Pointer".
+-- These Pointers are used to link together the different SDH level.
+-- SinkPointer is used to go UP in the hierarchie (go to the physical interface)
+-- and SourcePointer is used to go Down (go to VC and sub VC)
+-- These pointer can be used to retreive all the contained TTP
+-- or to retrieve the containing TTP and the physical interface (and board)
+
+-- Note on CTPIndex
+-- A CTP index is used to find a possible Connection Termination Point
+-- supported by a Trail Termination Point.
+-- If the CTP is not used for a Cross Connection the value is set to 0.
+
+-- Remark
+-- rstCTP and mstCTP are not implemented. The MIB can be upgraded if these
+-- level of Connection are used.
+
+--*******************************************************************
+--* TTP synchronous physical interface (spi)
+--*******************************************************************
+ SpiTTPFailure ::= INTEGER
+ {
+ none(0),
+ los(1),
+ tf(2),
+ losTf(3)
+ }
+
+ Loopback ::= INTEGER
+ {
+ none(0),
+ line(1),
+ equipment(2),
+ lineEquipement(3)
+ }
+
+ STMLevel ::= INTEGER
+ {
+ stm1(1),
+ stm4(4),
+ stm16(16),
+ stm64(64)
+ }
+ SpiTTPType ::= INTEGER
+ {
+ electrical(0),
+ optical(1)
+ }
+
+ spiTTPNumber OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of synchronous physical interface in equipment
+ = number of element in spiTTPTable "
+ ::= { spiTTP 1 }
+
+ spiTTPTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SpiTTPEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "List of synchronous physical interface in equipment."
+ ::= { spiTTP 2 }
+
+ spiTTPEntry OBJECT-TYPE
+ SYNTAX SpiTTPEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A particular synchronous physical interface of the equipment."
+ INDEX { spiTTPIndex }
+ ::= { spiTTPTable 1 }
+
+ SpiTTPEntry ::= SEQUENCE
+ {
+ spiTTPIndex INTEGER,
+ spiTTPStmLevel STMLevel,
+ spiTTPType SpiTTPType,
+ spiTTPName DisplayString,
+ spiTTPBoardIndex INTEGER,
+ spiTTPBoardAcces INTEGER,
+ spiTTPMonitor SagemBoolean,
+ spiTTPFailure SpiTTPFailure,
+ spiTTPSeverity Severity,
+ spiTTPLoopback Loopback,
+ spiTTPLos Severity,
+ spiTTPTf Severity
+ }
+
+ spiTTPIndex OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A unique value which identify a particular
+ synchronous physical interface.
+ The value of this index is a constant value assigned to an entry at
+ equipment design time. It is usualy related to harware.
+ Exemple:
+ For ADR155c equipement index are 1,64,127,190 for STM1 interfaces.
+ For ADR2500c equipement index are:
+ 1,1009,2017,3025,4033,5041,6049,7057 for 8 STM16 or 8 STM4,
+ 1,253,505,757 1009,1261,1513,1765 |
+ 2017,2269,2521,2773 3025,3277,3529,3781 | --> for 8 (4*STM1)
+ 4033,4285,4537,4789 5041,5293,5545,5797 |
+ 6049,6301,6553,6805 7057,7309,7561,7813 | "
+ ::= { spiTTPEntry 1 }
+
+ spiTTPStmLevel OBJECT-TYPE
+ SYNTAX STMLevel
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The STM-n level of the interface."
+ ::= { spiTTPEntry 2 }
+
+ spiTTPType OBJECT-TYPE
+ SYNTAX SpiTTPType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The kind of the interface: electrical or optical"
+ ::= { spiTTPEntry 3 }
+
+ spiTTPName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A text string which identifies the particular entry among the
+ synchronous physical interface entries. "
+ ::= { spiTTPEntry 4 }
+
+ spiTTPBoardIndex OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index of the Board that supports the physical acces
+ of this interface. This index refers to another MIB that defines
+ the board"
+ ::= { spiTTPEntry 5 }
+
+ spiTTPBoardAcces OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Friendly Index of the physical acces on the Board that supports
+ the interface"
+ ::= { spiTTPEntry 6 }
+
+ spiTTPMonitor OBJECT-TYPE
+ SYNTAX SagemBoolean
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "When the value of this field is set to false, the failure detection
+ is stopped for this synchronous physical interface."
+ ::= { spiTTPEntry 7 }
+
+ spiTTPFailure OBJECT-TYPE
+ SYNTAX SpiTTPFailure
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Active failures on synchronous physical interface"
+ ::= { spiTTPEntry 8 }
+
+ spiTTPSeverity OBJECT-TYPE
+ SYNTAX Severity
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Severity associed with active failure for synchronous physical interface."
+ ::= { spiTTPEntry 9 }
+
+ spiTTPLoopback OBJECT-TYPE
+ SYNTAX Loopback
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This field gives the active loopback status on the
+ synchronous physical interface.
+ When its value is `line' the data flow recieved from the port side
+ is sent back to the line.
+ When its value is `equipment' the data flow recieved form equipment
+ side is send back.
+ The field can be set to a particular loopback value, even if there
+ no garantee that the loopback is really done. The real loopback status
+ of the interface must be checked in the response.
+ The loopback can be cleared by the equipment when it cannot remain
+ for any reason."
+ ::= { spiTTPEntry 10 }
+
+ spiTTPLos OBJECT-TYPE
+ SYNTAX Severity
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Severity associed with Loss Of Signal failure
+ for synchronous physical interface."
+ ::= { spiTTPEntry 20 }
+
+ spiTTPTf OBJECT-TYPE
+ SYNTAX Severity
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Severity associed with Tranmit Fail failure
+ for synchronous physical interface."
+ ::= { spiTTPEntry 21 }
+ -- End of synchronous physical interface description
+
+
+--*******************************************************************
+--* regenerator section terminaison (rst)
+--*******************************************************************
+ RsTTPFailure ::= INTEGER
+ {
+ none(0), lof(1)
+ }
+
+ EOWMode ::= INTEGER
+ {
+ codirectional(0),
+ contradirectional(1)
+ }
+
+ rsTTPTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF RsTTPEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "List of regenerator section terminaison in equipment."
+ ::= { rsTTP 2 }
+
+ rsTTPEntry OBJECT-TYPE
+ SYNTAX RsTTPEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A particular regenerator section terminaison of the equipment."
+ INDEX {rsTTPIndex}
+ ::= { rsTTPTable 1 }
+
+ RsTTPEntry ::= SEQUENCE {
+ rsTTPIndex INTEGER, -- spi index
+ rsTTPMonitor SagemBoolean,
+ rsTTPName DisplayString,
+ rsTTPFailure RsTTPFailure,
+ rsTTPSeverity Severity,
+ rsTTPEOWMode EOWMode, -- co or contra
+ rsTTPE1SrcPointer INTEGER, -- Order Wire: index in x21Src
+ rsTTPF1SrcPointer INTEGER, -- User Chanel: not used
+ rsTTPEOWByteLine INTEGER,
+ rsTTPEOWByteColumn INTEGER,
+ rsTTPSesThreshold INTEGER,
+ rsTTPLof Severity
+ }
+
+ rsTTPIndex OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A unique value which identify a particular
+ synchronous physical interface.
+ The value of this index is always the same as spiTTPIndex.
+ "
+ ::= { rsTTPEntry 1 }
+
+ rsTTPMonitor OBJECT-TYPE
+ SYNTAX SagemBoolean
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "When the value of this field is set to false, the failure detection
+ is stopped for this regenerator section terminaison."
+ ::= { rsTTPEntry 2 }
+
+ rsTTPName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A text string which identifies the particular entry among the
+ regenerator section terminaison entries. "
+ ::= { rsTTPEntry 3 }
+
+ rsTTPFailure OBJECT-TYPE
+ SYNTAX RsTTPFailure
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Active failures on regenerator section terminaison"
+ ::= { rsTTPEntry 4 }
+
+ rsTTPSeverity OBJECT-TYPE
+ SYNTAX Severity
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Severity associed active Failure for regenerator section terminaison."
+ ::= { rsTTPEntry 5 }
+
+ rsTTPEOWMode OBJECT-TYPE
+ SYNTAX EOWMode
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Mode used for EOW: Codir or contradir Master"
+ ::= { rsTTPEntry 8 }
+
+ rsTTPE1SrcPointer OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A reference to the object which sends the data flow to
+ E1 RSOH byte (index in X21 table)
+ Usualy E1 carries X21 EOW (engineering order wire) data
+ and thus the pointer s value reference a mib X21 port entry.
+ Zero indicates not used"
+ ::= { rsTTPEntry 9 }
+
+ rsTTPF1SrcPointer OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A reference to the object which sends the data flow to
+ F1 RSOH byte.Zero indicates not used"
+ ::= { rsTTPEntry 10 }
+
+ rsTTPSesThreshold OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of errors above which the second is declared
+ severely errored for this interface/function.
+ This value apply for near and far interface/function
+ "
+ ::= { rsTTPEntry 11 }
+
+ rsTTPEOWByteLine OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The line determines the SOH byte selected for Engineering
+ Order Wire: SOH starts with 3 lines of RSOH (1,2,3) and
+ finish with 5 lines of MSOH (5,6,7,8,9)
+ E1 is on line 2 column 4.
+ Zero indicates EOW not used, value different from 2 means EOW
+ not on E1"
+ ::= { rsTTPEntry 12 }
+
+ rsTTPEOWByteColumn OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The column determines the SOH byte selected for Engineering
+ Order Wire: SOH is composed of Col [1,9]
+ E1 is on line 2 column 4.
+ Zero indicates EOW not used, value different from 4 means EOW
+ not on E1"
+ ::= { rsTTPEntry 13 }
+
+ rsTTPLof OBJECT-TYPE
+ SYNTAX Severity
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Severity associed with Loss Of Frame failure
+ for regenerator section terminaison."
+ ::= { rsTTPEntry 20 }
+ -- End of regenerator section terminaison description
+
+--*******************************************************************
+--* multiplex section terminaison (mst)
+--*******************************************************************
+ ProtectionType ::= INTEGER
+ {
+ none(0),
+ msp(1),
+ msSPRing(2)
+ }
+
+ MsTTPFailure ::= INTEGER
+ {
+ none(0),
+ ais(1),
+ eber(2),
+ sd(4),
+ sdRdi(12),
+ rdi(8)
+ }
+
+ msTTPTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF MsTTPEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "List of multiplex section terminaison in equipment."
+ ::= { msTTP 2 }
+
+ msTTPEntry OBJECT-TYPE
+ SYNTAX MsTTPEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A particular multiplex section terminaison of the equipment."
+ INDEX { msTTPIndex }
+ ::= { msTTPTable 1 }
+
+ MsTTPEntry ::= SEQUENCE
+ {
+ msTTPIndex INTEGER, -- spi Index
+ msTTPProtectionType ProtectionType,
+ msTTPMonitor SagemBoolean,
+ msTTPName DisplayString,
+ msTTPFailure MsTTPFailure,
+ msTTPSeverity Severity,
+ msTTPEOWMode EOWMode, -- co or contra
+ msTTPE2SrcPointer INTEGER, -- Order Wire: index in x21Src
+ msTTPMonEber SagemBoolean,
+ msTTPEOWByteLine INTEGER,
+ msTTPEOWByteColumn INTEGER,
+ msTTPSdThreshold INTEGER,
+ msTTPSesThreshold INTEGER,
+ msTTPEber Severity,
+ msTTPSd Severity,
+ msTTPRdi Severity
+ }
+
+ msTTPIndex OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A unique value which identify a particular
+ synchronous physical interface.
+ The value of this index is always the same as spiTTPIndex"
+ ::= { msTTPEntry 1 }
+
+ msTTPProtectionType OBJECT-TYPE
+ SYNTAX ProtectionType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The value of this field indicates the kind of wanted multiplex section protection.
+ The default value is NONE.
+ if value is changed in msp(1) or msSPRing(2) then (if it's possible) an entry is created
+ respectivelly in mspTable or msSPRingTable. But these tables have to be completed to obtain
+ a configured protection.
+ If value is changed in None(0)then the associated entry in mspTable or msSPRingTable is deleted
+ (if it's possible)."
+ ::= { msTTPEntry 2 }
+
+ msTTPMonitor OBJECT-TYPE
+ SYNTAX SagemBoolean
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "When the value of this field is set to false, the failure detection
+ is stopped for this multiplex section terminaison."
+ ::= { msTTPEntry 3 }
+
+ msTTPName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A text string which identifies the particular entry among the
+ multiplex section terminaison entries. "
+ ::= { msTTPEntry 4 }
+
+ msTTPFailure OBJECT-TYPE
+ SYNTAX MsTTPFailure
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Active failures on multiplex section terminaison"
+ ::= { msTTPEntry 5 }
+
+ msTTPSeverity OBJECT-TYPE
+ SYNTAX Severity
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Severity associed with active failures on multiplex section terminaison."
+ ::= { msTTPEntry 6 }
+
+ msTTPEOWMode OBJECT-TYPE
+ SYNTAX EOWMode
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Mode used for EOW: Codir or contradir Master"
+ ::= { msTTPEntry 7 }
+
+ msTTPE2SrcPointer OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A reference to the object which sends the data flow to
+ E2 MSOH byte.
+ Usualy E2 carries X21 EOW (engineering order wire) data.
+ The reference is an index in X21 table.Zero indicates not used"
+ ::= { msTTPEntry 8 }
+
+ msTTPEOWByteLine OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The line determines the SOH byte selected for Engineering
+ Order Wire: SOH starts with 3 lines of RSOH (1,2,3) and
+ finish with 5 lines of MSOH (5,6,7,8,9)
+ E2 is on line 9 column 7.
+ Zero indicates not used, value different from 9 means EOW
+ not on E2"
+ ::= { msTTPEntry 9 }
+
+ msTTPEOWByteColumn OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The column determines the SOH byte selected for Engineering
+ Order Wire: SOH is composed of Col [1,9]
+ E2 is on line 9 column 7.
+ Zero indicates EOW not used, value different from 7 means EOW
+ not on E2"
+ ::= { msTTPEntry 10 }
+
+ msTTPMonEber OBJECT-TYPE
+ SYNTAX SagemBoolean
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "If the value of this field is true, the eber is monitored and is used as
+ MSP and SETS criterium.
+ If this defect is detected, an ais signal is send downstream and
+ rdi upstream."
+ ::= { msTTPEntry 11 }
+
+ msTTPSdThreshold OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A Signal Degrade failure is declared if the error block rate is
+ greater than 1E(-mstSdThreshold).
+ The Signal Degrade failure desapeared when the error block rate is
+ less than 1E(1 - mstSdThreshold)."
+ ::= { msTTPEntry 12 }
+
+ msTTPSesThreshold OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of errors above which the second is declared
+ severely errored for this interface/function.
+ This value apply for near and far interface/function"
+ ::= { msTTPEntry 13 }
+
+ msTTPEber OBJECT-TYPE
+ SYNTAX Severity
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Severity associed with Excecive Bit Error Rate failure
+ for multiplex section terminaison."
+ ::= { msTTPEntry 20 }
+
+ msTTPSd OBJECT-TYPE
+ SYNTAX Severity
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Severity associed with Signal Degrade failure
+ for multiplex section terminaison."
+ ::= { msTTPEntry 21 }
+
+ msTTPRdi OBJECT-TYPE
+ SYNTAX Severity
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Severity associed with Remote Defect Indication failure
+ for multiplex section terminaison."
+ ::= { msTTPEntry 22 }
+ -- End of multiplex section terminaison description
+
+
+--*******************************************************************
+--* multiplex section adaptation (msa)
+--*
+--* This part allow to know all the VC4 provided by the current boards
+--* of the equipment. There is no relation with the configured connections
+--*******************************************************************
+
+ MsaSrcType ::= INTEGER
+ {
+ none(0),
+ msa(1),
+ vc4(2)
+ }
+
+ MsaSinkType ::= INTEGER
+ {
+ msa(0),
+ mst(1)
+ }
+
+ msaTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF MsaEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "List of multiplex section adaptation in equipment."
+ ::= { msa 2 }
+
+ msaEntry OBJECT-TYPE
+ SYNTAX MsaEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A particular multiplex section adaptation of the equipment."
+ INDEX { msaIndex }
+ ::= { msaTable 1 }
+
+ MsaEntry ::= SEQUENCE
+ {
+ msaIndex INTEGER, -- spiTTPIndex if msaSinkType = mst
+ msaSTMLevel STMLevel,
+ msaSinkType MsaSinkType, -- msa or mst
+ msaSinkPointer INTEGER, -- index in msa (msaIndex) or mst (spiTTPIndex)
+ msaName DisplayString,
+ msaSrc1Type MsaSrcType, --msa or vc4
+ msaSrc2Type MsaSrcType, --msa or vc4
+ msaSrc3Type MsaSrcType, --msa or vc4
+ msaSrc4Type MsaSrcType, --msa or vc4
+ msaSrc1Pointer INTEGER, -- index in msa (msaIndex) or mst (vc4Index)
+ msaSrc2Pointer INTEGER, -- index in msa (msaIndex) or mst (vc4Index), or 0
+ msaSrc3Pointer INTEGER, -- index in msa (msaIndex) or mst (vc4Index), or 0
+ msaSrc4Pointer INTEGER -- index in msa (msaIndex) or mst (vc4Index), or 0
+ }
+
+ msaIndex OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index of a particular entry among the
+ multiplex section adaptation entries. "
+ ::= { msaEntry 1 }
+
+ msaSTMLevel OBJECT-TYPE
+ SYNTAX STMLevel
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The STM-n level of the multiplex section adaptation."
+ ::= { msaEntry 2 }
+
+ msaSinkType OBJECT-TYPE
+ SYNTAX MsaSinkType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ " Type of msa sinkPointer: msa or mst"
+ ::= { msaEntry 3 }
+
+ msaSinkPointer OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A reference to the object which sends the data flow to this
+ function on synchronous port interface side.
+ In most equipments, this value cannot be changed and points to
+ the MST it is hard wired with."
+ ::= { msaEntry 4 }
+
+ msaName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A text string which identifies the particular entry among the
+ multiplex section adaptation entries. "
+ ::= { msaEntry 5 }
+
+ msaSrc1Type OBJECT-TYPE
+ SYNTAX MsaSrcType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Type of msa srcPointer: msa or vc4"
+ ::= { msaEntry 6 }
+
+ msaSrc2Type OBJECT-TYPE
+ SYNTAX MsaSrcType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Type of msa srcPointer: msa or vc4"
+ ::= { msaEntry 7 }
+
+ msaSrc3Type OBJECT-TYPE
+ SYNTAX MsaSrcType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Type of msa srcPointer: msa or vc4"
+ ::= { msaEntry 8 }
+
+ msaSrc4Type OBJECT-TYPE
+ SYNTAX MsaSrcType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Type of msa srcPointer: msa or vc4"
+ ::= { msaEntry 9 }
+
+ msaSrc1Pointer OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Table index of the object which sends the data flow to this
+ function on equipment side.
+ For STM16: 4 pseudo STM4 (group of 4STM1) identified by their
+ index in msaTable. Theses indexes must be differents to thoses
+ used by the MST Table.
+ For STM4: 4 VC4 identified by their index in vc4Table
+ For STM1: 1 VC4 identified by its index in vc4Table
+ "
+ ::= { msaEntry 10 }
+
+ msaSrc2Pointer OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A reference to the object which sends the data flow to this
+ function on equipment side.
+ In most equipments, this value cannot be changed and points to
+ the VC4 function it is hard wired with."
+ ::= { msaEntry 11 }
+
+ msaSrc3Pointer OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A reference to the object which sends the data flow to this
+ function on equipment side.
+ In most equipments, this value cannot be changed and points to
+ the VC4 function it is hard wired with."
+ ::= { msaEntry 12 }
+
+ msaSrc4Pointer OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A reference to the object which sends the data flow to this
+ function on equipment side.
+ In most equipments, this value cannot be changed and points to
+ the VC4 function it is hard wired with."
+ ::= { msaEntry 13 }
+ -- End of multiplex section adaptation description
+
+
+--*******************************************************************
+--* Common Types
+--*******************************************************************
+
+ CTPStatus ::= INTEGER
+ {
+ free (0),
+ used (1)
+ }
+
+
+--*******************************************************************
+--* CTP administrative unit order 4 (au4)
+--*******************************************************************
+ Au4CTPFailure ::= INTEGER
+ {
+ none(0),ais(1),lop(2),lom(3)
+ }
+
+ Au4CTPCnxType ::= INTEGER
+ {
+ none(0),au(1),au4c(4),au16c(16),tu(20)
+ }
+
+ au4CTPNumber OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of administrative unit order 4 in equipment."
+ ::= { au4CTP 1 }
+
+ au4CTPTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Au4CTPEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "List of administrative unit order 4 in equipment which are availables for new connection or
+ used in connection. In that case, an indication on the connection type is set
+ into the au4CTPCnxType Variable.
+ All au4 CTP, which are made up of lower connection level (tu3 or tu12), are set to 'used' value with
+ 'tu' type connection indication ."
+ ::= { au4CTP 2 }
+
+ au4CTPEntry OBJECT-TYPE
+ SYNTAX Au4CTPEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A particular administrative unit order 4 of the equipment."
+ INDEX { au4CTPIndex }
+ ::= { au4CTPTable 1 }
+
+ Au4CTPEntry ::= SEQUENCE
+ {
+ au4CTPIndex INTEGER,
+ au4CTPStatus CTPStatus, -- free or used
+ au4CTPCnxType Au4CTPCnxType, -- depends on the connection type (none if no connection)
+ au4CTPName DisplayString,
+ au4CTPMonitor SagemBoolean,
+ au4CTPFailure Au4CTPFailure,
+ au4CTPSeverity Severity,
+ au4CTPAis Severity,
+ au4CTPLop Severity,
+ au4CTPLom Severity
+ }
+
+ au4CTPIndex OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A unique value which identify a particular
+ administrative unit order 4.
+ The value of index is a constant assigned to an entry at
+ equipment design time. It is usualy related to harware."
+ ::= { au4CTPEntry 1 }
+
+ au4CTPStatus OBJECT-TYPE
+ SYNTAX CTPStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "au4 connection point Status: free or used.
+ The 'free' value is used when there is no connection with this output CTP"
+ ::= { au4CTPEntry 2 }
+
+ au4CTPCnxType OBJECT-TYPE
+ SYNTAX Au4CTPCnxType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "au4 connection Type: none, au4, au4-4c,au4-16c,tu.
+ The 'none' value is used when there is no connection with this output CTP"
+ ::= { au4CTPEntry 3 }
+
+ au4CTPName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A text string which identifies the particular entry among the
+ administrative unit order 4 entries. "
+ ::= { au4CTPEntry 4 }
+
+ au4CTPMonitor OBJECT-TYPE
+ SYNTAX SagemBoolean
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "When the value of this field is set to false, the failure detection
+ is stopped for this administrative unit order 4."
+ ::= { au4CTPEntry 6 }
+
+ au4CTPFailure OBJECT-TYPE
+ SYNTAX Au4CTPFailure
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Active failures on administrative unit order 4"
+ ::= { au4CTPEntry 7 }
+
+ au4CTPSeverity OBJECT-TYPE
+ SYNTAX Severity
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A reference to failure severity for administrative unit order 4."
+ ::= { au4CTPEntry 8 }
+
+ au4CTPAis OBJECT-TYPE
+ SYNTAX Severity
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Severity associed with Alarme Indication Signal failure
+ for administrative unit order 4."
+ ::= { au4CTPEntry 20 }
+
+ au4CTPLop OBJECT-TYPE
+ SYNTAX Severity
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Severity associed with Loss Of Pointer failure
+ for administrative unit order 4."
+ ::= { au4CTPEntry 21 }
+
+ au4CTPLom OBJECT-TYPE
+ SYNTAX Severity
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Severity associed with Loss Of MultiFrame failure
+ for administrative unit order 4."
+ ::= { au4CTPEntry 22 }
+
+ -- End of administrative unit order 4 description
+
+
+
+--*******************************************************************
+--* TTP virtual container order 4 (vc4-ttp)
+--*******************************************************************
+ Vc4TTPSinkType ::= INTEGER
+ {
+ mst (1),
+ nspi (2)
+ }
+
+ Vc4TTPTraceMode ::= INTEGER
+ {
+ size1 (1),
+ size16 (16)
+ }
+
+ Vc4TTPSignalLabel ::= INTEGER
+ {
+ unequiped(0), unspecified(1), tug(2), all1(255)
+ }
+
+ Vc4TTPFailure ::= INTEGER
+ {
+ none (0),rdi (1), sd (2), sdRdi (3),
+ uneq (4),uneqSd (6),plm (8), plmRdi (9), plmSd (10),
+ plmRdiSd(11),tim (16), timRdi(17), timSd (18),
+ timRdiSd(19)
+ }
+
+
+ vc4TTPNumber OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of virtual container order 4 in equipment."
+ ::= { vc4TTP 1 }
+
+ vc4TTPTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Vc4TTPEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "List of virtual container order 4 in equipment.The number of records depends on the kinds of
+ configured boards"
+ ::= { vc4TTP 2 }
+
+ vc4TTPEntry OBJECT-TYPE
+ SYNTAX Vc4TTPEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A particular virtual container order 4 of the equipment."
+ INDEX { vc4TTPIndex }
+ ::= { vc4TTPTable 1 }
+
+
+ Vc4TTPEntry ::= SEQUENCE
+ {
+ vc4TTPIndex INTEGER,
+ vc4TTPSinkPointer INTEGER, -- MSTindex or nspiTTPindex
+ vc4TTPSinkType Vc4TTPSinkType, -- MST or nspi
+ vc4TTPName DisplayString,
+ vc4TTPMonitor SagemBoolean,
+ vc4TTPFailure Vc4TTPFailure,
+ vc4TTPSeverity Severity,
+ vc4TTPTraceMode Vc4TTPTraceMode,
+ vc4TTPPathTraceExpected OCTET STRING (SIZE (16)),
+ vc4TTPPathTraceSent OCTET STRING (SIZE (16)),
+ vc4TTPPathTraceReceived OCTET STRING (SIZE (16)),
+ vc4TTPLabelExpected Vc4TTPSignalLabel,
+ vc4TTPLabelSent Vc4TTPSignalLabel,
+ vc4TTPLabelReceived Vc4TTPSignalLabel,
+ vc4TTPSdThreshold INTEGER,
+ vc4TTPSesThreshold INTEGER,
+ vc4TTPBidirectionnal SagemBoolean,
+ vc4TTPRdi Severity,
+ vc4TTPSd Severity,
+ vc4TTPUneq Severity,
+ vc4TTPPlm Severity,
+ vc4TTPTimDis SagemBoolean,
+ vc4TTPTim Severity
+ }
+
+ vc4TTPIndex OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A unique value which identify a particular
+ virtual container order 4.
+ The value of index is a constant assigned to an entry at
+ equipment design time. It is usualy related to harware."
+ ::= { vc4TTPEntry 1 }
+
+ vc4TTPSinkPointer OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A reference to the object which sends the data flow to this
+ function on synchronous or unsynchronous port interface side.
+ This pointer corresponds to an index in the msTTPTable or nspiTTPTable."
+ ::= { vc4TTPEntry 2 }
+
+ vc4TTPSinkType OBJECT-TYPE
+ SYNTAX Vc4TTPSinkType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A reference to the kind of the sink Pointer"
+ ::= { vc4TTPEntry 3 }
+
+ vc4TTPName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A text string which identifies the particular entry among the
+ virtual container order 4 entries. "
+ ::= { vc4TTPEntry 5 }
+
+ vc4TTPMonitor OBJECT-TYPE
+ SYNTAX SagemBoolean
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "When the value of this field is set to false, the failure detection
+ is stopped for this virtual container order 4."
+ ::= { vc4TTPEntry 6 }
+
+ vc4TTPFailure OBJECT-TYPE
+ SYNTAX Vc4TTPFailure
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Active failures on virtual container order 4"
+ ::= { vc4TTPEntry 7 }
+
+ vc4TTPSeverity OBJECT-TYPE
+ SYNTAX Severity
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A reference to failure severity for virtual container order 4."
+ ::= { vc4TTPEntry 8 }
+
+ vc4TTPTraceMode OBJECT-TYPE
+ SYNTAX Vc4TTPTraceMode
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Configuration of the pathTrace length (1 byte or 16 bytes)."
+ ::= { vc4TTPEntry 9 }
+
+ vc4TTPPathTraceExpected OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (16))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The path trace is a user string that always follows the vc4.
+ If the value the received path trace does not match this one, a
+ tim (Trail Identifier Mismatch) failure is issued.
+ The value `? ' match all possible received path trace."
+ ::= { vc4TTPEntry 11 }
+
+ vc4TTPPathTraceSent OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (16))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The path trace is a user string that always follows the vc4.
+ The value of this field is sent in j1 byte as path trace for this vc4.
+ The default value is `all 0'."
+ ::= { vc4TTPEntry 12 }
+
+ vc4TTPPathTraceReceived OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (16))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The path trace is a user string that always follows the vc4.
+ The value is the actual path trace received in j1 byte"
+ ::= { vc4TTPEntry 13 }
+
+ vc4TTPLabelExpected OBJECT-TYPE
+ SYNTAX Vc4TTPSignalLabel
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The signal label indicates the multiplexing structure of the vc4.
+ If the signal label received for this vc4 is not null and does
+ not match this field, a Signal Label Mismatch failure is detected.
+ If the received label is null a virtual container UNEQuiped
+ failure is detected."
+ ::= { vc4TTPEntry 14 }
+
+ vc4TTPLabelSent OBJECT-TYPE
+ SYNTAX Vc4TTPSignalLabel
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The signal label indicates the multiplexing structure of the vc4.
+ The value of this field in sent as signal label for the vc4."
+ ::= { vc4TTPEntry 15 }
+
+ vc4TTPLabelReceived OBJECT-TYPE
+ SYNTAX Vc4TTPSignalLabel
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The signal label indicates the multiplexing structure of the vc4.
+ The value of this field is the actual received signal label
+ for this vc4"
+ ::= { vc4TTPEntry 16 }
+
+ vc4TTPSdThreshold OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A Signal Degrade failure is declared if the error block rate is
+ greater than 1E(-SdThreshold).
+ The Signal Degrade failure desapeared when the error block rate is
+ less than 1E(1 - SdThreshold)."
+ ::= { vc4TTPEntry 17 }
+
+ vc4TTPSesThreshold OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of errors above which the second is declared
+ severely errored for this interface/function.
+ This value apply for near and far interface/function"
+ ::= { vc4TTPEntry 18 }
+
+ vc4TTPBidirectionnal OBJECT-TYPE
+ SYNTAX SagemBoolean
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "If set to false the equipment does not send Remote Defect Indication."
+ ::= { vc4TTPEntry 19 }
+
+ vc4TTPRdi OBJECT-TYPE
+ SYNTAX Severity
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Severity associed with Remote Defect Indication failure
+ for virtual container order 4."
+ ::= { vc4TTPEntry 20 }
+
+ vc4TTPSd OBJECT-TYPE
+ SYNTAX Severity
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Severity associed with Signal Degrade failure
+ for virtual container order 4."
+ ::= { vc4TTPEntry 21 }
+
+ vc4TTPUneq OBJECT-TYPE
+ SYNTAX Severity
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Severity associed with virtual container UNEQuiped failure
+ for virtual container order 4."
+ ::= { vc4TTPEntry 22 }
+
+ vc4TTPPlm OBJECT-TYPE
+ SYNTAX Severity
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Severity associed with Path Label Mismatch failure
+ for virtual container order 4."
+ ::= { vc4TTPEntry 23 }
+
+ vc4TTPTimDis OBJECT-TYPE
+ SYNTAX SagemBoolean
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "If set to true the equipment does not manage the Tim Failure."
+ ::= { vc4TTPEntry 24 }
+
+ vc4TTPTim OBJECT-TYPE
+ SYNTAX Severity
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Severity associed with Trail Identifier Mismatch failure
+ for virtual container order 4."
+ ::= { vc4TTPEntry 25 }
+ -- End of virtual container order 4 description
+
+
+
+--*******************************************************************
+--* CTP tributary unit 3 (tu3)
+--*******************************************************************
+
+ Tu3CTPFailure ::= INTEGER
+ {
+ none (0),
+ ais (1),
+ lop (2)
+ }
+
+ tu3CTPNumber OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of tributary unit in equipment."
+ ::= { tu3CTP 1 }
+
+ tu3CTPTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Tu3CTPEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "List of tributary units order 3 in equipment which are availables for new connection or used in
+ the same connection level. In that case, an indication on the connection point status is set into the
+ tu3CTPStatus Variable.
+ All tu3 CTP, which are involved in different connection level (tu12 or au4), disappear from
+ this List."
+ ::= { tu3CTP 2 }
+
+ tu3CTPEntry OBJECT-TYPE
+ SYNTAX Tu3CTPEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A particular tributary unit of the equipment."
+ INDEX { tu3CTPIndex}
+ ::= { tu3CTPTable 1 }
+
+ Tu3CTPEntry ::= SEQUENCE
+ {
+ tu3CTPIndex INTEGER,
+ tu3CTPStatus CTPStatus, -- free or used
+ tu3CTPName DisplayString,
+ tu3CTPMonitor SagemBoolean,
+ tu3CTPFailure Tu3CTPFailure,
+ tu3CTPSeverity Severity,
+ tu3CTPAis Severity,
+ tu3CTPLop Severity
+ }
+
+ tu3CTPIndex OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index that identifies the particular entry among the
+ tributary unit entries. "
+ ::= { tu3CTPEntry 1 }
+
+ tu3CTPStatus OBJECT-TYPE
+ SYNTAX CTPStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "tu3 connection point Status: free or used.
+ The 'free' value is used when there is no connection with this output CTP"
+ ::= { tu3CTPEntry 2 }
+
+ tu3CTPName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A text string which identifies the particular entry among the
+ tributary unit entries. "
+ ::= { tu3CTPEntry 5 }
+
+ tu3CTPMonitor OBJECT-TYPE
+ SYNTAX SagemBoolean
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "When the value of this field is set to false, the failure detection
+ is stopped for this tributary unit."
+ ::= { tu3CTPEntry 6 }
+
+ tu3CTPFailure OBJECT-TYPE
+ SYNTAX Tu3CTPFailure
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Active failures on tributary unit"
+ ::= { tu3CTPEntry 7 }
+
+ tu3CTPSeverity OBJECT-TYPE
+ SYNTAX Severity
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A reference to failure severity for tributary unit."
+ ::= { tu3CTPEntry 8 }
+
+ tu3CTPAis OBJECT-TYPE
+ SYNTAX Severity
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Severity associed with Alarme Indication Signal failure
+ for tributary unit."
+ ::= { tu3CTPEntry 20 }
+
+ tu3CTPLop OBJECT-TYPE
+ SYNTAX Severity
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Severity associed with Loss Of Pointer failure
+ for tributary unit."
+ ::= { tu3CTPEntry 21 }
+ -- End of tributary unit description
+
+--*******************************************************************
+--* CTP tributary unit 12 (tu12)
+--*******************************************************************
+
+ Tu12CTPFailure ::= INTEGER
+ {
+ none (0),
+ ais (1),
+ lop (2)
+ }
+
+ tu12CTPNumber OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of tributary unit in equipment."
+ ::= { tu12CTP 1 }
+
+ tu12CTPTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Tu12CTPEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "List of tributary unit order 12 in equipment which are availables for new connection or
+ used in the same connection level. In that case, an indication on the connection point Status
+ is set into the tu12CTPStatus Variable.
+ All tu12 CTP, which are involved in a different connection level (tu3 or au4), disappear from
+ this List."
+ ::= { tu12CTP 2 }
+
+ tu12CTPEntry OBJECT-TYPE
+ SYNTAX Tu12CTPEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A particular tributary unit of the equipment."
+ INDEX { tu12CTPIndex }
+ ::= { tu12CTPTable 1 }
+
+ Tu12CTPEntry ::= SEQUENCE
+ {
+ tu12CTPIndex INTEGER,
+ tu12CTPStatus CTPStatus, -- free or used
+ tu12CTPName DisplayString,
+ tu12CTPMonitor SagemBoolean,
+ tu12CTPFailure Tu12CTPFailure,
+ tu12CTPSeverity Severity,
+ tu12CTPAis Severity,
+ tu12CTPLop Severity
+ }
+
+ tu12CTPIndex OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A unique value which identify a particular tu12."
+ ::= { tu12CTPEntry 1 }
+
+ tu12CTPStatus OBJECT-TYPE
+ SYNTAX CTPStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "tu12 connection point Status: free or used.
+ The 'free' value is used when there is no connection with this output CTP"
+ ::= { tu12CTPEntry 2 }
+
+ tu12CTPName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A text string which identifies the particular entry among the
+ tributary unit entries. "
+ ::= { tu12CTPEntry 5 }
+
+ tu12CTPMonitor OBJECT-TYPE
+ SYNTAX SagemBoolean
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "When the value of this field is set to false, the failure detection
+ is stopped for this tributary unit."
+ ::= { tu12CTPEntry 6 }
+
+ tu12CTPFailure OBJECT-TYPE
+ SYNTAX Tu12CTPFailure
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Active failures on tributary unit"
+ ::= { tu12CTPEntry 7 }
+
+ tu12CTPSeverity OBJECT-TYPE
+ SYNTAX Severity
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A reference to failure severity for tributary unit."
+ ::= { tu12CTPEntry 8 }
+
+ tu12CTPAis OBJECT-TYPE
+ SYNTAX Severity
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Severity associed with Alarme Indication Signal failure
+ for tributary unit."
+ ::= { tu12CTPEntry 20 }
+
+ tu12CTPLop OBJECT-TYPE
+ SYNTAX Severity
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Severity associed with Loss Of Pointer failure
+ for tributary unit."
+ ::= { tu12CTPEntry 21 }
+
+ -- End of tributary unit description
+
+--*******************************************************************
+--* virtual container order 3 (vc3)
+--*******************************************************************
+ Vc3TTPSinkType ::= INTEGER
+ {
+ vc4 (1),
+ nspi (2)
+ }
+
+ Vc3TTPSignalLabel ::= INTEGER
+ {
+ unequiped(0), unspecified(1),
+ mapping3445(4), all1(7)
+ }
+
+ VcLoFailure ::= INTEGER
+ {
+ none (0),
+ rdi (1),
+ sd (2), sdRdi (3),
+ uneq (4), uneqSd (6),
+ plm (8), plmRdi (9), plmSd (10), plmRdiSd(11),
+ tim (16), timRdi(17), timSd (18), timRdiSd(19)
+ }
+
+ vc3TTPNumber OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of virtual container order 3 in equipment."
+ ::= { vc3TTP 1 }
+
+ vc3TTPTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Vc3TTPEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "List of virtual container order 3 in equipment.The number of records depends on the kinds of
+ configured boards"
+ ::= { vc3TTP 2 }
+
+ vc3TTPEntry OBJECT-TYPE
+ SYNTAX Vc3TTPEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A particular virtual container order 3 of the equipment."
+ INDEX { vc3TTPIndex }
+ ::= { vc3TTPTable 1 }
+
+
+ Vc3TTPEntry ::= SEQUENCE
+ {
+ vc3TTPIndex INTEGER,
+ vc3TTPSinkPointer INTEGER, -- nspiTTPIndex or VC4index
+ vc3TTPSinkType Vc3TTPSinkType, -- Nspi or VC4
+ vc3TTPName DisplayString,
+ vc3TTPMonitor SagemBoolean,
+ vc3TTPFailure VcLoFailure,
+ vc3TTPSeverity Severity,
+ vc3TTPPathTraceExpected OCTET STRING,
+ vc3TTPPathTraceSent OCTET STRING,
+ vc3TTPPathTraceReceived OCTET STRING,
+ vc3TTPLabelExpected Vc3TTPSignalLabel,
+ vc3TTPLabelSent Vc3TTPSignalLabel,
+ vc3TTPLabelReceived Vc3TTPSignalLabel,
+ vc3TTPSdThreshold INTEGER,
+ vc3TTPSesThreshold INTEGER,
+ vc3TTPBidirectionnal SagemBoolean,
+ vc3TTPRdi Severity,
+ vc3TTPSd Severity,
+ vc3TTPUneq Severity,
+ vc3TTPPlm Severity,
+ vc3TTPTim Severity
+ }
+
+
+ vc3TTPIndex OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A unique value which identify a particular
+ virtual container order 3.
+ The value of index is a constant assigned to an entry at
+ equipment design time. It is usualy related to harware."
+ ::= { vc3TTPEntry 1 }
+
+ vc3TTPSinkPointer OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A reference to the object which sends the data flow to this
+ function on non-sdh physical port side."
+ ::= { vc3TTPEntry 2 }
+
+ vc3TTPSinkType OBJECT-TYPE
+ SYNTAX Vc3TTPSinkType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A reference to the kind of the sink Pointer"
+ ::= { vc3TTPEntry 3 }
+
+ vc3TTPName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A text string which identifies the particular entry among the
+ virtual container order 3 entries. "
+ ::= { vc3TTPEntry 5 }
+
+ vc3TTPMonitor OBJECT-TYPE
+ SYNTAX SagemBoolean
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "When the value of this field is set to false, the failure detection
+ is stopped for this virtual container order 3."
+ ::= { vc3TTPEntry 6 }
+
+ vc3TTPFailure OBJECT-TYPE
+ SYNTAX VcLoFailure
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Active failures on virtual container order 3"
+ ::= { vc3TTPEntry 7 }
+
+ vc3TTPSeverity OBJECT-TYPE
+ SYNTAX Severity
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A reference to failure severity for virtual container order 3."
+ ::= { vc3TTPEntry 8 }
+
+ vc3TTPPathTraceExpected OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (16))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The path trace is a user string that always follows the vc3.
+ If the value the received path trace does not match this one, a
+ tim (Trail Identifier Mismatch) failure is issued.
+ The value `? ' match all possible received path trace."
+ ::= { vc3TTPEntry 9 }
+
+ vc3TTPPathTraceSent OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (1..15))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The path trace is a user string that always follows the vc3.
+ The value of this field is sent in j1 byte as path trace for this vc3.
+ The default value is `all 0'."
+ ::= { vc3TTPEntry 10 }
+
+ vc3TTPPathTraceReceived OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (15))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The path trace is a user string that always follows the vc3.
+ The value is the actual path trace received in j1 byte"
+ ::= { vc3TTPEntry 11 }
+
+ vc3TTPLabelExpected OBJECT-TYPE
+ SYNTAX Vc3TTPSignalLabel
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The signal label indicates the multiplexing structure of the vc3.
+ Usualy the value of this field cannot be modified as most equipment
+ use the asynchronous bit multiplexing.
+ For historical reasons the receipt of label `unspecified ' does not
+ produce a Signal Label Mismatch failure."
+ ::= { vc3TTPEntry 12 }
+
+ vc3TTPLabelSent OBJECT-TYPE
+ SYNTAX Vc3TTPSignalLabel
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The signal label indicates the multiplexing structure of the vc3.
+ The value of this field is sent as signal label for the vc3.
+ The unspecified value is used for compatibilty with old sdh
+ equipments.
+ The `unequiped' value actives low order unequiped generator (lug).
+ In this case all 1 signal is inserted down and up stream."
+ ::= { vc3TTPEntry 13 }
+
+ vc3TTPLabelReceived OBJECT-TYPE
+ SYNTAX Vc3TTPSignalLabel
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The signal label indicates the multiplexing structure of the vc3.
+ The value of this field is the actual received signal label
+ for this vc3"
+ ::= { vc3TTPEntry 14 }
+
+ vc3TTPSdThreshold OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A Signal Degrade failure is declared if the error block rate is
+ greater than 1E(-SdThreshold).
+ The Signal Degrade failure desapeared when the error block rate is
+ less than 1E(1 - SdThreshold)."
+ ::= { vc3TTPEntry 15 }
+
+ vc3TTPSesThreshold OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of errors above which the second is declared
+ severely errored for this interface/function.
+ This value apply for near and far interface/function"
+ ::= { vc3TTPEntry 16 }
+
+ vc3TTPBidirectionnal OBJECT-TYPE
+ SYNTAX SagemBoolean
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "If set to false the equipment does not send Remote Defect Indication."
+ ::= { vc3TTPEntry 17 }
+
+ vc3TTPRdi OBJECT-TYPE
+ SYNTAX Severity
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Severity associed with Remote Defect Indication failure
+ for virtual container order 3."
+ ::= { vc3TTPEntry 20 }
+
+ vc3TTPSd OBJECT-TYPE
+ SYNTAX Severity
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Severity associed with Signal Degrade failure
+ for virtual container order 3."
+ ::= { vc3TTPEntry 21 }
+
+ vc3TTPUneq OBJECT-TYPE
+ SYNTAX Severity
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Severity associed with virtual container UNEQuiped failure
+ for virtual container order 3."
+ ::= { vc3TTPEntry 22 }
+
+ vc3TTPPlm OBJECT-TYPE
+ SYNTAX Severity
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Severity associed with Path Label Mismatch failure
+ for virtual container order 3."
+ ::= { vc3TTPEntry 23 }
+
+ vc3TTPTim OBJECT-TYPE
+ SYNTAX Severity
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Severity associed with Trail Identifier Mismatch failure
+ for virtual container order 3."
+ ::= { vc3TTPEntry 24 }
+ -- End of virtual container order 3 description
+
+--*******************************************************************
+--* virtual container order 12 (vc12)
+--*******************************************************************
+ Vc12TTPSinkType ::= INTEGER
+ {
+ vc4 (1),
+ nspi (2)
+ }
+
+ Vc12TTPSignalLabel ::= INTEGER
+ {
+ unequiped(0), unspecified(1),
+ asyncBit(2), all1(7)
+ }
+
+ vc12TTPNumber OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of virtual container order 12 in equipment."
+ ::= { vc12TTP 1 }
+
+ vc12TTPTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Vc12TTPEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "List of virtual container order 12 in equipment.The number of records depends on the kinds of
+ configured boards"
+ ::= { vc12TTP 2 }
+
+ vc12TTPEntry OBJECT-TYPE
+ SYNTAX Vc12TTPEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A particular virtual container order 12 of the equipment."
+ INDEX { vc12TTPIndex }
+ ::= { vc12TTPTable 1 }
+
+
+ Vc12TTPEntry ::= SEQUENCE
+ {
+ vc12TTPIndex INTEGER,
+ vc12TTPSinkPointer INTEGER, -- nspiTTPIndex or VC4index
+ vc12TTPSinkType Vc12TTPSinkType, -- Nspi or Vc4
+ vc12TTPName DisplayString,
+ vc12TTPMonitor SagemBoolean,
+ vc12TTPFailure VcLoFailure,
+ vc12TTPSeverity Severity,
+ vc12TTPPathTraceExpected OCTET STRING,
+ vc12TTPPathTraceSent OCTET STRING,
+ vc12TTPPathTraceReceived OCTET STRING,
+ vc12TTPLabelExpected Vc12TTPSignalLabel,
+ vc12TTPLabelSent Vc12TTPSignalLabel,
+ vc12TTPLabelReceived Vc12TTPSignalLabel,
+ vc12TTPSdThreshold INTEGER,
+ vc12TTPSesThreshold INTEGER,
+ vc12TTPBidirectionnal SagemBoolean,
+ vc12TTPRdi Severity,
+ vc12TTPSd Severity,
+ vc12TTPUneq Severity,
+ vc12TTPPlm Severity,
+ vc12TTPTim Severity
+ }
+
+ vc12TTPIndex OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A unique value which identify a particular
+ virtual container order 12.
+ The value of index is a constant assigned to an entry at
+ equipment design time. It is usualy related to harware."
+ ::= { vc12TTPEntry 1 }
+
+ vc12TTPSinkPointer OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A reference to the object which sends the data flow to this
+ function on non-sdh physical port side."
+ ::= { vc12TTPEntry 2 }
+
+ vc12TTPSinkType OBJECT-TYPE
+ SYNTAX Vc12TTPSinkType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A reference to the kind of the sink Pointer"
+ ::= { vc12TTPEntry 3 }
+
+ vc12TTPName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A text string which identifies the particular entry among the
+ virtual container order 12 entries. "
+ ::= { vc12TTPEntry 5 }
+
+ vc12TTPMonitor OBJECT-TYPE
+ SYNTAX SagemBoolean
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "When the value of this field is set to false, the failure detection
+ is stopped for this virtual container order 12."
+ ::= { vc12TTPEntry 6 }
+
+ vc12TTPFailure OBJECT-TYPE
+ SYNTAX VcLoFailure
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Active failures on virtual container order 12"
+ ::= { vc12TTPEntry 7 }
+
+ vc12TTPSeverity OBJECT-TYPE
+ SYNTAX Severity
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A reference to failure severity for virtual container order 12."
+ ::= { vc12TTPEntry 8 }
+
+
+ vc12TTPPathTraceExpected OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (16))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The path trace is a user string that always follows the vc12.
+ If the value the received path trace does not match this one, a
+ tim (Trail Identifier Mismatch) failure is issued.
+ The value `? ' match all possible received path trace."
+ ::= { vc12TTPEntry 9 }
+
+ vc12TTPPathTraceSent OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (16))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The path trace is a user string that always follows the vc12.
+ The value of this field is sent in j2 byte as path trace for this vc12.
+ The default value is `all 0'."
+ ::= { vc12TTPEntry 10 }
+
+ vc12TTPPathTraceReceived OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (16))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The path trace is a user string that always follows the vc12.
+ The value is the actual path trace received in j2 byte"
+ ::= { vc12TTPEntry 11 }
+
+ vc12TTPLabelExpected OBJECT-TYPE
+ SYNTAX Vc12TTPSignalLabel
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The signal label indicates the multiplexing structure of the vc12.
+ Usualy the value of this field cannot be modified as most equipment
+ use the asynchronous bit multiplexing.
+ For historical reasons the receipt of label `unspecified ' does not
+ produce a Signal Label Mismatch failure."
+ ::= { vc12TTPEntry 12 }
+
+ vc12TTPLabelSent OBJECT-TYPE
+ SYNTAX Vc12TTPSignalLabel
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The signal label indicates the multiplexing structure of the vc12.
+ The value of this field is sent as signal label for the vc12.
+ The unspecified value is used for compatibilty with old sdh
+ equipments.
+ The `unequiped' value actives low order unequiped generator (lug).
+ In this case all 1 signal is inserted down and up stream."
+ ::= { vc12TTPEntry 13 }
+
+ vc12TTPLabelReceived OBJECT-TYPE
+ SYNTAX Vc12TTPSignalLabel
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The signal label indicates the multiplexing structure of the vc12.
+ The value of this field is the actual received signal label
+ for this vc12"
+ ::= { vc12TTPEntry 14 }
+
+ vc12TTPSdThreshold OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A Signal Degrade failure is declared if the error block rate is
+ greater than 1E(-SdThreshold).
+ The Signal Degrade failure desapeared when the error block rate is
+ less than 1E(1 - SdThreshold)."
+ ::= { vc12TTPEntry 15 }
+
+ vc12TTPSesThreshold OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of errors above which the second is declared
+ severely errored for this interface/function.
+ This value apply for near and far interface/function"
+ ::= { vc12TTPEntry 16 }
+
+ vc12TTPBidirectionnal OBJECT-TYPE
+ SYNTAX SagemBoolean
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "If set to false the equipment does not send Remote Defect Indication."
+ ::= { vc12TTPEntry 17 }
+
+ vc12TTPRdi OBJECT-TYPE
+ SYNTAX Severity
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Severity associed with Remote Defect Indication failure
+ for virtual container order 12."
+ ::= { vc12TTPEntry 20 }
+
+ vc12TTPSd OBJECT-TYPE
+ SYNTAX Severity
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Severity associed with Signal Degrade failure
+ for virtual container order 12."
+ ::= { vc12TTPEntry 21 }
+
+ vc12TTPUneq OBJECT-TYPE
+ SYNTAX Severity
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Severity associed with virtual container UNEQuiped failure
+ for virtual container order 12."
+ ::= { vc12TTPEntry 22 }
+
+ vc12TTPPlm OBJECT-TYPE
+ SYNTAX Severity
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Severity associed with Path Label Mismatch failure
+ for virtual container order 12."
+ ::= { vc12TTPEntry 23 }
+
+ vc12TTPTim OBJECT-TYPE
+ SYNTAX Severity
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Severity associed with Trail Identifier Mismatch failure
+ for virtual container order 12."
+ ::= { vc12TTPEntry 24 }
+ -- End of virtual container order 12 description
+
+
+
+--*******************************************************************
+--* non synchronous physical port (nspi)
+--*******************************************************************
+
+ NspiSrcType ::= INTEGER
+ {
+ vc12 (1),
+ vc3 (2),
+ vc4 (3),
+ channel (4)
+ }
+
+--*******************************************************************
+--* Nspi CTP
+--*******************************************************************
+
+ nspiCTPNumber OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A unique value which identify a particular non-sdh physical port.
+ The value of index is a constant assigned to an entry at
+ equipment design time. It is usualy related to harware."
+ ::= { nspiCTP 1 }
+
+ nspiCTPTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF NspiCTPEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "List of non-sdh physical port in equipment."
+ ::= { nspiCTP 2 }
+
+ nspiCTPEntry OBJECT-TYPE
+ SYNTAX NspiCTPEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A particular non-sdh physical port of the equipment."
+ INDEX { nspiCTPIndex }
+ ::= { nspiCTPTable 1 }
+
+
+ NspiCTPEntry ::= SEQUENCE
+ {
+ nspiCTPIndex INTEGER,
+ nspiCTPTTPType NspiSrcType, -- VC3, VC12 or VC4
+ nspiCTPStatus CTPStatus, -- free or used
+ nspiCTPName DisplayString
+ }
+
+ nspiCTPIndex OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A unique value which identify a particular
+ non-sdh physical port.
+ The value of index is a constant assigned to an entry at
+ equipment design time. It is usualy related to harware."
+ ::= { nspiCTPEntry 1 }
+
+ nspiCTPTTPType OBJECT-TYPE
+ SYNTAX NspiSrcType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The type of VC which is associated to the nspi interface."
+ ::= { nspiCTPEntry 2 }
+
+ nspiCTPStatus OBJECT-TYPE
+ SYNTAX CTPStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "nspi connection point Status: free or used.
+ The 'free' value is used when there is no connection with this output CTP"
+ ::= { nspiCTPEntry 3 }
+
+ nspiCTPName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A text string which identifies the particular entry among the
+ non-sdh physical port entries. "
+ ::= { nspiCTPEntry 4 }
+
+ -- End of non-sdh physical port description
+
+
+--*******************************************************************
+--* Nspi TTP
+--*******************************************************************
+ NspiTTPFailure ::= INTEGER
+ {
+ none (0),
+ los (1),
+ ais (2)
+ }
+
+ NspiTTPType ::= INTEGER
+ {
+ g703R75ohm (1),
+ g703R120ohm (2),
+ x21 (10),
+ ethernet (20),
+ atm (30)
+ }
+
+ NspiTTPLevel ::= INTEGER
+ {
+ rate2Mb (2),
+ rate10Mb (10),
+ rate34Mb (34),
+ rate45Mb (45),
+ rate100Mb (100),
+ rate140Mb (140),
+ rate1Gb (1000)
+ }
+
+
+ nspiTTPNumber OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A unique value which identify a particular non-sdh physical port.
+ The value of index is a constant assigned to an entry at
+ equipment design time. It is usualy related to harware."
+ ::= { nspiTTP 1 }
+
+ nspiTTPTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF NspiTTPEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "List of non-sdh physical port in equipment."
+ ::= { nspiTTP 2 }
+
+ nspiTTPEntry OBJECT-TYPE
+ SYNTAX NspiTTPEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A particular non-sdh physical port of the equipment."
+ INDEX { nspiTTPIndex }
+ ::= { nspiTTPTable 1 }
+
+ NspiTTPEntry ::= SEQUENCE
+ {
+ nspiTTPIndex INTEGER,
+ nspiTTPType NspiTTPType,
+ nspiTTPLevel NspiTTPLevel,
+ nspiTTPName DisplayString,
+ nspiTTPBoardIndex INTEGER,
+ nspiTTPBoardAcces INTEGER,
+ nspiTTPSrcType NspiSrcType, -- VC3, VC12 or VC4
+ nspiTTPSrcPointer INTEGER, -- VC index
+ nspiTTPMonitor SagemBoolean,
+ nspiTTPFailure NspiTTPFailure,
+ nspiTTPSeverity Severity,
+ nspiTTPLoopback Loopback,
+ nspiTTPLos Severity,
+ nspiTTPAis Severity
+ }
+
+ nspiTTPIndex OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A unique value which identify a particular
+ non-sdh physical port.
+ The value of index is a constant assigned to an entry at
+ equipment design time. It is usualy related to harware."
+ ::= { nspiTTPEntry 1 }
+
+ nspiTTPType OBJECT-TYPE
+ SYNTAX NspiTTPType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The type of media for the nspi interface."
+ ::= { nspiTTPEntry 2 }
+
+ nspiTTPLevel OBJECT-TYPE
+ SYNTAX NspiTTPLevel
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The rate level of the nspi interface."
+ ::= { nspiTTPEntry 3 }
+
+ nspiTTPName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A text string which identifies the particular entry among the
+ non-sdh physical port entries. "
+ ::= { nspiTTPEntry 4 }
+
+ nspiTTPBoardIndex OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index of the Board that supports the physical acces
+ of this interface"
+ ::= { nspiTTPEntry 5 }
+
+ nspiTTPBoardAcces OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Friendly Index of the physical acces on the Board that supports
+ the interface"
+ ::= { nspiTTPEntry 6 }
+
+ nspiTTPSrcType OBJECT-TYPE
+ SYNTAX NspiSrcType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A reference to the type of object which sends the data flow to this
+ interface. Usually the value is vc12, vc3 or vc4 types."
+ ::= { nspiTTPEntry 7 }
+
+ nspiTTPSrcPointer OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A reference to the object which sends the data flow to this
+ interface. Usually the value is the Index of a vc12, vc3 or vc4."
+ ::= { nspiTTPEntry 8 }
+
+ nspiTTPMonitor OBJECT-TYPE
+ SYNTAX SagemBoolean
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "When the value of this field is set to false, the failure detection
+ is stopped for this non-sdh physical port."
+ ::= { nspiTTPEntry 9 }
+
+ nspiTTPFailure OBJECT-TYPE
+ SYNTAX NspiTTPFailure
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Active failures on non-sdh physical port"
+ ::= { nspiTTPEntry 10 }
+
+ nspiTTPSeverity OBJECT-TYPE
+ SYNTAX Severity
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A reference to failure severity for non-sdh physical port."
+ ::= { nspiTTPEntry 11 }
+
+ nspiTTPLoopback OBJECT-TYPE
+ SYNTAX Loopback
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This field gives the active loopback status on the
+ non-sdh physical port.
+ When its value is `line' the data flow recieved from the port side
+ is sent back to the line.
+ When its value is `equipment' the data flow recieved form equipment
+ side is send back.
+ The field can be set to a particular loopback value, even if there
+ no garantee that the loopback is really done. The real loopback status
+ of the interface must be checked in the response.
+ The loopback can be cleared by the equipment when it cannot remain
+ for any reason."
+ ::= { nspiTTPEntry 14 }
+
+ nspiTTPLos OBJECT-TYPE
+ SYNTAX Severity
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Severity associed with Loss Of Signal failure
+ for non-sdh physical port."
+ ::= { nspiTTPEntry 20 }
+
+ nspiTTPAis OBJECT-TYPE
+ SYNTAX Severity
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Severity associed with Alarme Indication Signal failure
+ for non-sdh physical port."
+ ::= { nspiTTPEntry 21 }
+ -- End of non-sdh physical port description
+
+
+--*******************************************************************
+--* Channel
+--* This part allows to add a new decomposition level between nspi ports
+--* and SDH Containers.
+--*******************************************************************
+ ChannelEncaps ::= INTEGER
+ {
+ none (0),
+ atm (1),
+ pos (2),
+ gfp (3)
+ }
+
+ ChannelConcat ::= INTEGER
+ {
+ none (0),
+ virtual (1),
+ contiguous (2)
+ }
+
+ ChannelFailure ::= INTEGER
+ {
+ none (0),
+ loa (1),
+ lom (2),
+ sqm (3)
+ }
+
+
+ channelNumber OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of SDH Channels in equipment."
+ ::= { channel 1 }
+
+ channelTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ChannelEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "List of SDH Channels in equipment."
+ ::= { channel 2 }
+
+ channelEntry OBJECT-TYPE
+ SYNTAX ChannelEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A particular SDH Channel of the equipment."
+ INDEX { channelIndex }
+ ::= { channelTable 1 }
+
+ ChannelEntry ::= SEQUENCE
+ {
+ channelIndex INTEGER, -- nspiTTPIndex
+ channelEncaps ChannelEncaps,
+ channelNbVc4 INTEGER,
+ channelNbVc3 INTEGER,
+ channelNbVc12 INTEGER,
+ channelConcat ChannelConcat,
+ channelAdminStatus INTEGER,
+ channelOperStatus INTEGER,
+ channelFirstIndex INTEGER,
+ channelDelay INTEGER,
+ channelMonitor SagemBoolean,
+ channelFailure ChannelFailure,
+ channelSeverity Severity,
+ channelLoa Severity,
+ channelLom Severity,
+ channelSqm Severity
+ }
+
+ channelIndex OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A unique value which identify a particular
+ SDH Channel.
+ The value of index is a constant assigned to an entry at
+ equipment design time. It is usualy related to harware."
+ ::= { channelEntry 1 }
+
+ channelEncaps OBJECT-TYPE
+ SYNTAX ChannelEncaps
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The type of encapsulation used to map Data stream into Sdh containers"
+ ::= { channelEntry 2 }
+
+ channelNbVc4 OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number of VC4 into the channel. "
+ ::= { channelEntry 5 }
+
+ channelNbVc3 OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number of VC3 into the channel. "
+ ::= { channelEntry 6 }
+
+ channelNbVc12 OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number of VC12 into the channel. "
+ ::= { channelEntry 7 }
+
+ channelConcat OBJECT-TYPE
+ SYNTAX ChannelConcat
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The type of Concatenation used within the channel"
+ ::= { channelEntry 8 }
+
+ channelAdminStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ up(1), -- ready to pass packets
+ down(2),
+ testing(3) -- in some test mode
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The desired state of the channel. The
+ testing(3) state indicates that no operational
+ packets can be passed."
+ ::= { channelEntry 9 }
+
+ channelOperStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ up(1), -- ready to pass packets
+ down(2),
+ testing(3) -- in some test mode
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current operational state of the channel.
+ The testing(3) state indicates that no operational
+ packets can be passed."
+ ::= { channelEntry 10 }
+
+ channelFirstIndex OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Index of the first Vc in the Channel when it is configured.
+ Otherwise this field is set to 0. "
+ ::= { channelEntry 11 }
+
+ channelDelay OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This field give the maximum delay (in millisecondes) for receiving virtual concatenated frames.
+ This field is set to 0 when channelConcat is different to virtual(1) "
+ ::= { channelEntry 12 }
+
+ channelMonitor OBJECT-TYPE
+ SYNTAX SagemBoolean
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "When the value of this field is set to false, the failure detection
+ is stopped for this channel."
+ ::= { channelEntry 13 }
+
+ channelFailure OBJECT-TYPE
+ SYNTAX ChannelFailure
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Active failures on channel"
+ ::= { channelEntry 14 }
+
+ channelSeverity OBJECT-TYPE
+ SYNTAX Severity
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A reference to failure severity for non-sdh physical port."
+ ::= { channelEntry 15 }
+
+ channelLoa OBJECT-TYPE
+ SYNTAX Severity
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Severity associated with Loss Of Alignment failure
+ for channel."
+ ::= { channelEntry 16 }
+
+ channelLom OBJECT-TYPE
+ SYNTAX Severity
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Severity associated with Loss Of Multiframe failure
+ for channel."
+ ::= { channelEntry 17 }
+
+ channelSqm OBJECT-TYPE
+ SYNTAX Severity
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Severity associated with Sequence Mismatch failure
+ for channel."
+ ::= { channelEntry 18 }
+ -- End of Channel description
+
+
+
+--*******************************************************************
+--* Bandwidth
+--* This part allows to configure the bandwidth allocated to a Data Card
+--* It gives references of VC which are used by channels.
+--*******************************************************************
+
+ bandwidthNumber OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of bandwidth units which are available in the equipement.
+ The number of units depends on their type (Vc4, Vc3, Vc12), on the number
+ of Data card and on the bandwidth size which has been configured for this card.
+ For a Data card which is mapped on a STM16, there are 16 Vc4 entries (or 3*16 Vc3 entries
+ or 63*16 Vc12 entries) in the BandwidthTable. "
+ ::= { bandwidth 1 }
+
+ bandwidthTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BandwidthEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "List of Bandwidth units in equipment. It represent the bandwidth occupation of each non-sdh card"
+ ::= { bandwidth 2 }
+
+ bandwidthEntry OBJECT-TYPE
+ SYNTAX BandwidthEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A particular unit part of a non-sdh card bandwidth."
+ INDEX { bandwidthIndex }
+ ::= { bandwidthTable 1 }
+
+ BandwidthEntry ::= SEQUENCE
+ {
+ bandwidthIndex INTEGER, -- VC index
+ bandwidthBoardIndex INTEGER, -- BoardIndex
+ bandwidthSrcType NspiSrcType, -- VC3, VC12 or VC4
+ bandwidthSrcPointer INTEGER, -- VC index
+ bandwidthSinkType NspiSrcType, -- Channel
+ bandwidthSinkPointer INTEGER, -- channelIndex
+ bandwidthAdminStatus INTEGER,
+ bandwidthOperStatus INTEGER,
+ bandwidthPrevIndex INTEGER, -- VC index
+ bandwidthNextIndex INTEGER -- VC index
+ }
+
+ bandwidthIndex OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A unique value which identify a particular unit of a non-sdh card bandwidth.
+ The value of index is a Vc Index which change when bandwidthSrcType value is modified. "
+ ::= { bandwidthEntry 1 }
+
+ bandwidthBoardIndex OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index of the Board that supports the bandwidth unit."
+ ::= { bandwidthEntry 2 }
+
+ bandwidthSrcType OBJECT-TYPE
+ SYNTAX NspiSrcType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Define the decomposition level of the bandwidth."
+ ::= { bandwidthEntry 3 }
+
+ bandwidthSrcPointer OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "this field is set to bandwidthIndex when the unit is used by a channel and set to 0 otherwise.
+ It defines the TTP and CTP index associated to the channel. "
+ ::= { bandwidthEntry 4 }
+
+ bandwidthSinkType OBJECT-TYPE
+ SYNTAX NspiSrcType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A reference to the kind of the sink Pointer. Usually the value is Channel."
+ ::= { bandwidthEntry 5 }
+
+ bandwidthSinkPointer OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A reference to the object which sends the data flow to this
+ function on unsynchronous port interface side.
+ This pointer corresponds to an index in the channelTable. "
+ ::= { bandwidthEntry 6 }
+
+ bandwidthAdminStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ up(1), -- ready to pass packets
+ down(2),
+ testing(3) -- in some test mode
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The desired state of the Vc. The
+ testing(3) state indicates that no operational
+ packets can be passed."
+ ::= { bandwidthEntry 7 }
+
+ bandwidthOperStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ up(1), -- ready to pass packets
+ down(2),
+ testing(3) -- in some test mode
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current operational state of the Vc.
+ The testing(3) state indicates that no operational
+ packets can be passed."
+ ::= { bandwidthEntry 8 }
+
+ bandwidthPrevIndex OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A reference to the previous VC into the channel. This field is set to 0 if the VC is not
+ associated to a channel or if it is the first Vc of the channel. "
+ ::= { bandwidthEntry 9 }
+
+ bandwidthNextIndex OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A reference to the next VC into the channel. This field is set to 0 if the VC is not
+ associated to a channel or if it is the last Vc of the channel. "
+ ::= { bandwidthEntry 10 }
+
+ -- End of Bandwidth description
+
+ END
+
+
|