diff --git a/MIBS/schleifenbauer/SCHLEIFENBAUER-DATABUS-MIB b/MIBS/schleifenbauer/SCHLEIFENBAUER-DATABUS-MIB
new file mode 100644
index 0000000..823a560
--- /dev/null
+++ b/MIBS/schleifenbauer/SCHLEIFENBAUER-DATABUS-MIB
@@ -0,0 +1,2151 @@
+-------------------------------------------------------------------------------
+--
+-- SCHLEIFENBAUER-DATABUS-MIB.txt: Schleifenbauer MIB for databus devices
+--
+-- Copyright (c) 2016, 2020 by Schleifenbauer Holding BV
+-- All rights reserved.
+--
+-------------------------------------------------------------------------------
+
+SCHLEIFENBAUER-DATABUS-MIB DEFINITIONS ::= BEGIN
+
+IMPORTS
+ MODULE-IDENTITY,
+ OBJECT-TYPE,
+ Integer32,
+ Unsigned32,
+ NOTIFICATION-TYPE
+ FROM SNMPv2-SMI
+ OBJECT-GROUP,
+ NOTIFICATION-GROUP,
+ MODULE-COMPLIANCE
+ FROM SNMPv2-CONF
+ TEXTUAL-CONVENTION,
+ DisplayString
+ FROM SNMPv2-TC
+ schleifenbauerMgmt
+ FROM SCHLEIFENBAUER-SMI;
+
+schleifenbauerDatabusMIB MODULE-IDENTITY
+ LAST-UPDATED
+ "202004280000Z" -- April 28th, 2020
+ ORGANIZATION
+ "Schleifenbauer Engineering"
+ CONTACT-INFO
+ "Schleifenbauer Engineering
+ Alain Schuermans
+ Chief Technology Officer
+ Rietwaard 15
+ 5236 WC 's-Hertogenbosch
+ The Netherlands
+ t +31 (0)73 52 30256
+ f +31 (0)73 521 23 83
+ alain@schleifenbauer.eu
+ www.schleifenbauer.eu"
+ DESCRIPTION
+ "This MIB describes the SNMP functions of network enabled databus
+ devices.
+
+ Copyright (c) 2016, 2020 by Schleifenbauer Holding BV
+ "
+ REVISION
+ "202004280000Z" -- April 28th, 2020
+ DESCRIPTION
+ "1. Added performance monitoring registers
+ 2. Added sdbDevStUsbMode register
+ 3. Added sdbDevIdDeviceType register
+ 4. Added sdbDevIdLocateUnit"
+ REVISION
+ "201703060000Z" -- March 3rd, 2017
+ DESCRIPTION
+ "Renamed Deci prefix of custom TEXTUAL-CONVENTIONs to Centi"
+ REVISION
+ "201610210000Z" -- October 21th, 2016
+ DESCRIPTION
+ "1. Added sdbDevSsOutletVoltageDropAlert object.
+ 2. Added sdbDevStAutoResetAlerts object.
+ 3. Added sdbDevStExtendedNames object.
+ 4. Added sdbDevSsOutletVoltageDropAlertDetected object."
+ REVISION
+ "201606160000Z" -- June 16th, 2016
+ DESCRIPTION
+ "1. Fixed incorrect range of sdbDevIdIndex."
+ REVISION
+ "201605100000Z" -- May 10th, 2016
+ DESCRIPTION
+ "1. Added sdbDevOutMtPowerVoltAmpere object.
+ 2. Added sdbDevOutMtPowerWatt object."
+ REVISION
+ "201603240000Z" -- March 24th, 2016
+ DESCRIPTION
+ "1. Added sdbMgmtStsRingState object.
+ 2. Added sdbMgmtStsBreachIndex object.
+ 3. Added sdbMgmtStsRingStateChanged notification."
+ REVISION
+ "201602190000Z" -- February 19th, 2016
+ DESCRIPTION
+ "1. Fixed incorrect description of sdbDevIdIndex.
+ 2. Fixed description of sdbDevSsSensorChangeAlertDetected. Removed
+ sdbDevSnsType from description."
+ REVISION
+ "201510230000Z" -- October 23th, 2015
+ DESCRIPTION
+ "The initial revision of this MIB module"
+ ::= { schleifenbauerMgmt 1 }
+
+CentiValue ::= TEXTUAL-CONVENTION
+ DISPLAY-HINT "d-2"
+ STATUS current
+ DESCRIPTION
+ "Data type for reporting generic measurements associated with
+ environmental sensors. If the underlying hardware sensor indicates
+ 21.1 degrees Celsius, then the SNMP agent will report a value of 2110
+ CentiValue."
+ SYNTAX Integer32 (0..327680)
+
+KiloWattHour ::= TEXTUAL-CONVENTION
+ DISPLAY-HINT "d"
+ STATUS current
+ DESCRIPTION
+ "Data type for reporting measurements associated with energy
+ accumulation sensors. If the underlying hardware sensor indicates 1
+ kWh, then the SNMP agent will report a value of 1 kWh."
+ SYNTAX Integer32 (0..16777215)
+
+-- START MIB --
+
+CentiAmpere ::= TEXTUAL-CONVENTION
+ DISPLAY-HINT "d-2"
+ STATUS current
+ DESCRIPTION
+ "Data type for reporting measurements and thresholds associated with
+ current sensors. If the underlying hardware sensor indicates 1.1 A,
+ then the SNMP agent will report a value of 110 CentiAmpere."
+ SYNTAX Integer32 (0..327680)
+
+CentiCelsius ::= TEXTUAL-CONVENTION
+ DISPLAY-HINT "d-2"
+ STATUS current
+ DESCRIPTION
+ "Data type for reporting sensor readings associated with temperature
+ sensors. If the underlying hardware sensor indicates 20.1 degrees
+ Celsius, then the SNMP agent will report a value of 2010 CentiCelsius."
+ SYNTAX Integer32 (0..9900)
+
+CentiPercent ::= TEXTUAL-CONVENTION
+ DISPLAY-HINT "d-2"
+ STATUS current
+ DESCRIPTION
+ "Data type for reporting calculated percentages. If the calculated
+ percentage is 98.3%, then the SNMP agent will report a value of 9830
+ CentiPercent."
+ SYNTAX Integer32 (0..10000)
+
+CentiVolt ::= TEXTUAL-CONVENTION
+ DISPLAY-HINT "d-2"
+ STATUS current
+ DESCRIPTION
+ "Data type for reporting measurements and thresholds associated with
+ voltage sensors. If the underlying hardware sensor indicates 231.1 V,
+ then the SNMP agent will report a value of 23110 CentiVolt."
+ SYNTAX Integer32 (0..327680)
+
+MilliSecond ::= TEXTUAL-CONVENTION
+ DISPLAY-HINT "d"
+ STATUS current
+ DESCRIPTION
+ "Duration in milliseconds"
+ SYNTAX Integer32
+
+Second ::= TEXTUAL-CONVENTION
+ DISPLAY-HINT "d"
+ STATUS current
+ DESCRIPTION
+ "Duration in seconds."
+ SYNTAX Integer32
+
+sdbMIBNotifications OBJECT IDENTIFIER ::= { schleifenbauerDatabusMIB 0 }
+sdbMIBObjects OBJECT IDENTIFIER ::= { schleifenbauerDatabusMIB 1 }
+sdbMIBConformance OBJECT IDENTIFIER ::= { schleifenbauerDatabusMIB 2 }
+
+sdbMgmt OBJECT IDENTIFIER ::= { sdbMIBObjects 1}
+sdbDevice OBJECT IDENTIFIER ::= { sdbMIBObjects 2 }
+
+sdbMgmtStatus OBJECT IDENTIFIER ::= { sdbMgmt 1 }
+sdbMgmtControl OBJECT IDENTIFIER ::= { sdbMgmt 2 }
+
+sdbDevIdentification OBJECT IDENTIFIER ::= { sdbDevice 1 }
+sdbDevConfiguration OBJECT IDENTIFIER ::= { sdbDevice 2 }
+sdbDevSystemStatus OBJECT IDENTIFIER ::= { sdbDevice 3 }
+sdbDevReset OBJECT IDENTIFIER ::= { sdbDevice 4 }
+sdbDevSettings OBJECT IDENTIFIER ::= { sdbDevice 5 }
+sdbDevInput OBJECT IDENTIFIER ::= { sdbDevice 6 }
+sdbDevOutlet OBJECT IDENTIFIER ::= { sdbDevice 7 }
+sdbDevSensor OBJECT IDENTIFIER ::= { sdbDevice 8 }
+sdbDevPerformance OBJECT IDENTIFIER ::= { sdbDevice 9 }
+
+sdbMIBCompliances OBJECT IDENTIFIER ::= { sdbMIBConformance 1 }
+sdbMIBGroups OBJECT IDENTIFIER ::= { sdbMIBConformance 2 }
+
+sdbMgmtStsDevices OBJECT-TYPE
+ SYNTAX Integer32 (1..512)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of devices on the databus."
+ ::= { sdbMgmtStatus 1}
+
+sdbMgmtStsAddressableDevices OBJECT-TYPE
+ SYNTAX Integer32 (1..255)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of devices on the databus addressable by snmp."
+ ::= { sdbMgmtStatus 2 }
+
+sdbMgmtStsNewDevices OBJECT-TYPE
+ SYNTAX Integer32 (1..255)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of new devices on the databus."
+ ::= { sdbMgmtStatus 3 }
+
+sdbMgmtStsDuplicateDevices OBJECT-TYPE
+ SYNTAX Integer32 (1..255)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of duplicate devices on the databus."
+ ::= { sdbMgmtStatus 4 }
+
+sdbMgmtStsRingState OBJECT-TYPE
+ SYNTAX INTEGER {
+ open(0),
+ closed(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "If the device is in a bridge-like mode, this will indicate the actual
+ state of the databus."
+ ::= { sdbMgmtStatus 5 }
+
+sdbMgmtStsRingBreachIndex OBJECT-TYPE
+ SYNTAX Integer32 (0..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the breach index if the current state of the data bus is
+ open. If the data bus is closed this has no meaning."
+ ::= { sdbMgmtStatus 6 }
+
+sdbMgmtCtrlScan OBJECT-TYPE
+ SYNTAX INTEGER {
+ idle(0),
+ scan(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Perform a bus scan.
+ To verify if scanning is completed the value of this object can be
+ read. During the bus scan the value remains 1. When the bus scan
+ completed the value will be 0."
+ ::= { sdbMgmtControl 1 }
+
+sdbMgmtCtrlRenumberAllFromN OBJECT-TYPE
+ SYNTAX Integer32 (0..65535)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Renumber all devices on the databus.
+ If set to 0 all units will be set to 0. If set to another value, all
+ units will be numbered in sequence starting from the value set."
+ ::= { sdbMgmtControl 2 }
+
+sdbMgmtCtrlRenumberZeros OBJECT-TYPE
+ SYNTAX INTEGER {
+ idle(0),
+ renumber(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Renumber all devices on the databus having address 0.
+ Renumbering will be done in sequence. The sequence starts with the
+ highest address found on the databus."
+ ::= { sdbMgmtControl 3 }
+
+sdbMgmtCtrlDevicesTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SdbMgmtCtrlDevicesEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table containing information of devices connected to the databus.
+ The number of entries is given by the value of sdbMgmtStsDevices."
+ ::= { sdbMgmtControl 4 }
+
+sdbMgmtCtrlDevicesEntry OBJECT-TYPE
+ SYNTAX SdbMgmtCtrlDevicesEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Information entry containing objects of a particular databus device."
+ INDEX { sdbMgmtCtrlDevIndex }
+ ::= { sdbMgmtCtrlDevicesTable 1 }
+
+SdbMgmtCtrlDevicesEntry ::=
+ SEQUENCE {
+ sdbMgmtCtrlDevIndex Integer32,
+ sdbMgmtCtrlDevUnitAddress Integer32,
+ sdbMgmtCtrlDevHardwareAddress DisplayString,
+ sdbMgmtCtrlDevIsNew Integer32,
+ sdbMgmtCtrlDevIsDuplicate Integer32
+ }
+
+sdbMgmtCtrlDevIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..255)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A unique value for each device. Its value ranges between 1 and the
+ value of sdbMgmtStsDevices with a maximum of 255. The value for each
+ device will remain constant until the next scan is performed."
+ ::= { sdbMgmtCtrlDevicesEntry 1 }
+
+sdbMgmtCtrlDevUnitAddress OBJECT-TYPE
+ SYNTAX Integer32 (0..65535)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "User defined address.
+ This will be used for addressing the device on the databus."
+ ::= { sdbMgmtCtrlDevicesEntry 2 }
+
+sdbMgmtCtrlDevHardwareAddress OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(17))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Hardware serial number.
+ This cannot be changed. It can be used as backup unit address.
+ format as 3 unsigned ints separated by dashes: int - int - int"
+ ::= { sdbMgmtCtrlDevicesEntry 3 }
+
+sdbMgmtCtrlDevIsNew OBJECT-TYPE
+ SYNTAX INTEGER {
+ no(0),
+ yes(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indication if the device is new on the databus."
+ ::= { sdbMgmtCtrlDevicesEntry 4 }
+
+sdbMgmtCtrlDevIsDuplicate OBJECT-TYPE
+ SYNTAX
+ INTEGER {
+ no(0),
+ yes(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indication if the device is conflicting with another device on the
+ databus."
+ ::= { sdbMgmtCtrlDevicesEntry 5 }
+
+sdbDevIdTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SdbDevIdEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table containing identification information of devices connected to
+ the databus.
+ The number of entries is given by the value of
+ sdbMgmtStsAddressableDevices."
+ ::= { sdbDevIdentification 1 }
+
+sdbDevIdEntry OBJECT-TYPE
+ SYNTAX SdbDevIdEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Information entry containing information objects of a particular
+ databus device."
+ INDEX { sdbDevIdIndex }
+ ::= { sdbDevIdTable 1 }
+
+SdbDevIdEntry ::=
+ SEQUENCE {
+ sdbDevIdSPDMVersion Integer32,
+ sdbDevIdFirmwareVersion Integer32,
+ sdbDevIdBuildNumber DisplayString,
+ sdbDevIdSalesOrderNumber DisplayString,
+ sdbDevIdProductId DisplayString,
+ sdbDevIdSerialNumber DisplayString,
+ sdbDevIdHardwareAddress DisplayString,
+ sdbDevIdMacAddress DisplayString,
+ sdbDevIdUnitAddress Integer32,
+ sdbDevIdName DisplayString,
+ sdbDevIdLocation DisplayString,
+ sdbDevIdVanityTag DisplayString,
+ sdbDevIdIndex Integer32,
+ sdbDevIdDeviceType Integer32,
+ sdbDevIdLocateUnit Integer32
+ }
+
+sdbDevIdSPDMVersion OBJECT-TYPE
+ SYNTAX Integer32 (0..9999)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Data model version."
+ ::= { sdbDevIdEntry 1 }
+
+sdbDevIdFirmwareVersion OBJECT-TYPE
+ SYNTAX Integer32 (0..9999)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The firmware revision number."
+ ::= { sdbDevIdEntry 2 }
+
+sdbDevIdBuildNumber OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..12))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Date and time the firmware was built."
+ ::= { sdbDevIdEntry 3 }
+
+sdbDevIdSalesOrderNumber OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..16))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "SP sales order number."
+ ::= { sdbDevIdEntry 4 }
+
+sdbDevIdProductId OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..16))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "SP product id."
+ ::= { sdbDevIdEntry 5 }
+
+sdbDevIdSerialNumber OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..16))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "SP serial number."
+ ::= { sdbDevIdEntry 6 }
+
+sdbDevIdHardwareAddress OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(17))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Hardware serial number.
+ This can not be changed. It can be used as backup unit address.
+ Format as 3 unsigned ints separated by dashes (-)
+ e.g. 12345-54321-00000"
+ ::= { sdbDevIdEntry 7 }
+
+sdbDevIdMacAddress OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(17))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The MAC address.
+ This can not be changed. It represents an 802 MAC address as if it
+ were transmitted least significant bit first.
+ Format as six groups of 2 hexadecimal digits separated by colons (:)
+ e.g. D0:22:12:B0:00:00"
+ ::= { sdbDevIdEntry 8 }
+
+sdbDevIdUnitAddress OBJECT-TYPE
+ SYNTAX Integer32 (0..65535)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "User defined address.
+ This will be used for addressing the device on the databus."
+ ::= { sdbDevIdEntry 9 }
+
+sdbDevIdName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..16))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "User configurable device name or identifier."
+ ::= { sdbDevIdEntry 10 }
+
+sdbDevIdLocation OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..16))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "User configurable device location identifier."
+ ::= { sdbDevIdEntry 11 }
+
+sdbDevIdVanityTag OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..20))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Characters to be displayed as vanity text in display."
+ ::= { sdbDevIdEntry 12 }
+
+sdbDevIdIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A unique value for each device. Its value represents the unit address
+ of the device and is used to address individual devices in the tree.
+ The value for each device will remain constant until the next scan is
+ performed."
+ ::= { sdbDevIdEntry 13 }
+
+sdbDevIdDeviceType OBJECT-TYPE
+ SYNTAX INTEGER {
+ pdu(0),
+ dpm(1),
+ hpdu-G3(2),
+ dpm27e(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A unique value for each device group.
+ Its value represents the device type of the device.
+ Refer to manual for more information."
+ ::= { sdbDevIdEntry 14 }
+
+sdbDevIdLocateUnit OBJECT-TYPE
+ SYNTAX INTEGER {
+ off(0),
+ on(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The LCD-backlight flashes in a heartbeat rhythm to locate the unit."
+ ::= { sdbDevIdEntry 15 }
+
+sdbDevCfTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SdbDevCfEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table containing configuration information of devices connected to
+ the databus.
+ The number of entries is given by the value of
+ sdbMgmtStsAddressableDevices."
+ ::= { sdbDevConfiguration 1 }
+
+sdbDevCfEntry OBJECT-TYPE
+ SYNTAX SdbDevCfEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Configuration entry containing configuration objects of a particular
+ databus device."
+ INDEX { sdbDevIdIndex }
+ ::= { sdbDevCfTable 1 }
+
+SdbDevCfEntry ::=
+ SEQUENCE {
+ sdbDevCfPhases Integer32,
+ sdbDevCfOutletsTotal Integer32,
+ sdbDevCfOutletsSwitched Integer32,
+ sdbDevCfOutletsMetered Integer32,
+ sdbDevCfSensors Integer32,
+ sdbDevCfMaximumLoad Integer32
+ }
+
+sdbDevCfPhases OBJECT-TYPE
+ SYNTAX Integer32 (0 | 1 | 3)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of phases for input metering."
+ ::= { sdbDevCfEntry 1 }
+
+sdbDevCfOutletsTotal OBJECT-TYPE
+ SYNTAX Integer32 (0..48)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of outlets including hardwired without switch/metered
+ modules."
+ ::= { sdbDevCfEntry 2 }
+
+sdbDevCfOutletsSwitched OBJECT-TYPE
+ SYNTAX Integer32 (0..48)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of switched outlets.
+ If outlet numbering is non-contiguous its the highest outlet number."
+ ::= { sdbDevCfEntry 3 }
+
+sdbDevCfOutletsMetered OBJECT-TYPE
+ SYNTAX Integer32 (0..48)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of metered outlets.
+ If outlet numbering is non-contiguous its the highest outlet number."
+ ::= { sdbDevCfEntry 4 }
+
+sdbDevCfSensors OBJECT-TYPE
+ SYNTAX Integer32 (0..16)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number sensors."
+ ::= { sdbDevCfEntry 5 }
+
+sdbDevCfMaximumLoad OBJECT-TYPE
+ SYNTAX Integer32 (16 | 32)
+ UNITS "A"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Maximum rated load of device per phase"
+ ::= { sdbDevCfEntry 6 }
+
+sdbDevSsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SdbDevSsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table containing system status information of devices connected to
+ the databus.
+ The number of entries is given by the value of
+ sdbMgmtStsAddressableDevices."
+ ::= { sdbDevSystemStatus 1 }
+
+sdbDevSsEntry OBJECT-TYPE
+ SYNTAX SdbDevSsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "System status entry containing system status objects of a particular
+ databus device."
+ INDEX { sdbDevIdIndex }
+ ::= { sdbDevSsTable 1 }
+
+SdbDevSsEntry ::=
+ SEQUENCE {
+ sdbDevSsDeviceStatusCode Integer32,
+ sdbDevSsTemperatureAlert Integer32,
+ sdbDevSsInputCurrentAlert Integer32,
+ sdbDevSsOutletCurrentAlert Integer32,
+ sdbDevSsInputVoltageAlert Integer32,
+ sdbDevSsOutletCurrentDropAlert Integer32,
+ sdbDevSsInputCurrentDropAlert Integer32,
+ sdbDevSsSensorChangeAlert Integer32,
+ sdbDevSsOutletVoltageDropAlert Integer32
+ }
+
+sdbDevSsDeviceStatusCode OBJECT-TYPE
+ SYNTAX Integer32 (0..255)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Returns an internal status or error code.
+ A value of 0 means OK.
+ If not 0 it can be any of the following codes. Multiple status codes
+ can be active at the same time. The value will be the sum of the
+ active status codes.
+
+ 1 = alert flagged
+ 2 = settings(s) initialized
+ 4 = power-on reset
+ 8 = external reset
+ 16 = watchdog timer caused reset
+ 32 = brownout detected
+ 64 = controller error
+ 128 = slave module was reset"
+ ::= { sdbDevSsEntry 1 }
+
+sdbDevSsTemperatureAlert OBJECT-TYPE
+ SYNTAX Integer32 (0..2)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An alert has been raised due to temperature exceeding treshhold.
+ 0 = no alert
+ 1 = internal temperature sensor
+ 2 = external temperature sensor"
+ ::= { sdbDevSsEntry 2 }
+
+sdbDevSsInputCurrentAlert OBJECT-TYPE
+ SYNTAX Integer32 (0..3)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An alert has been raised due to current exceeding treshhold.
+ The value indicates the exceeding phase. 0 = no alert."
+ ::= { sdbDevSsEntry 3 }
+
+sdbDevSsOutletCurrentAlert OBJECT-TYPE
+ SYNTAX Integer32 (0..48)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An alert has been raised due to current exceeding treshhold.
+ The value indicates the exceeding outlet. 0 = no alert."
+ ::= { sdbDevSsEntry 4 }
+
+sdbDevSsInputVoltageAlert OBJECT-TYPE
+ SYNTAX Integer32 (0..3)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An alert has been raised due to a voltage dip.
+ The value indicates the dipped phase. 0 = no alert."
+ ::= { sdbDevSsEntry 5 }
+
+sdbDevSsOutletCurrentDropAlert OBJECT-TYPE
+ SYNTAX Integer32 (0..48)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An alert has been raised due to the current of a metered outlet
+ suddenly dropping to near zero, possibly indicating a blown fuse.
+ The value indicates the dropped outlet. 0 = no alert."
+ ::= { sdbDevSsEntry 6 }
+
+sdbDevSsInputCurrentDropAlert OBJECT-TYPE
+ SYNTAX Integer32 (0..3)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An alert has been raised due to the current of a metered input
+ suddenly dropping to near zero, possibly indicating a blown fuse.
+ The value indicates the dropped phase. 0 = no alert."
+ ::= { sdbDevSsEntry 7 }
+
+sdbDevSsSensorChangeAlert OBJECT-TYPE
+ SYNTAX Integer32 (0..16)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An alert has been raised due to a change in the number of sensors.
+ The value indicates the previous amount of sensors."
+ ::= { sdbDevSsEntry 8 }
+
+sdbDevSsOutletVoltageDropAlert OBJECT-TYPE
+ SYNTAX Integer32 (0..48)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An alert has been raised due to voltage drop on this outlet.
+ The value indicates the first failed outlet."
+ ::= { sdbDevSsEntry 9 }
+
+
+sdbDevRsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SdbDevRsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table providing reset capabilities to devices connected to the
+ databus.
+ The number of entries is given by the value of
+ sdbMgmtStsAddressableDevices."
+ ::= { sdbDevReset 1 }
+
+sdbDevRsEntry OBJECT-TYPE
+ SYNTAX SdbDevRsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Reset entry providing reset objects of a particular databus device."
+ INDEX { sdbDevIdIndex }
+ ::= { sdbDevRsTable 1 }
+
+SdbDevRsEntry ::=
+ SEQUENCE {
+ sdbDevRsReboot Integer32,
+ sdbDevRsResetAlerts Integer32,
+ sdbDevRsZeroInputKWhSubtotal Integer32,
+ sdbDevRsZeroOutletKWhSubtotal Integer32,
+ sdbDevRsResetPeaksAndDips Integer32
+ }
+
+sdbDevRsReboot OBJECT-TYPE
+ SYNTAX
+ INTEGER {
+ idle(0),
+ reboot(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Warm reboot/reset of device controller.
+ NOTE: this will have NO effect on outlet status!"
+ ::= { sdbDevRsEntry 1 }
+
+sdbDevRsResetAlerts OBJECT-TYPE
+ SYNTAX
+ INTEGER {
+ idle(0),
+ reset(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Reset all alert signals and device status code."
+ ::= { sdbDevRsEntry 2 }
+
+sdbDevRsZeroInputKWhSubtotal OBJECT-TYPE
+ SYNTAX
+ INTEGER {
+ idle(0),
+ zero(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Reset of all input kWh subtotal counters to zero."
+ ::= { sdbDevRsEntry 3 }
+
+sdbDevRsZeroOutletKWhSubtotal OBJECT-TYPE
+ SYNTAX
+ INTEGER {
+ idle(0),
+ zero(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Reset of all outlet kWh subtotal counter to zero."
+ ::= { sdbDevRsEntry 4 }
+
+sdbDevRsResetPeaksAndDips OBJECT-TYPE
+ SYNTAX
+ INTEGER {
+ idle(0),
+ reset(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Reset all peak and dip values to zero."
+ ::= { sdbDevRsEntry 5 }
+
+sdbDevStTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SdbDevStEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table containing setting information of devices connected to the
+ databus.
+ The number of entries is given by the value of
+ sdbMgmtStsAddressableDevices."
+ ::= { sdbDevSettings 1 }
+
+sdbDevStEntry OBJECT-TYPE
+ SYNTAX SdbDevStEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Setting entry containing settings objects of a particular databus
+ device."
+ INDEX { sdbDevIdIndex }
+ ::= { sdbDevStTable 1 }
+
+SdbDevStEntry ::=
+ SEQUENCE {
+ sdbDevStAutoResetAlerts Integer32,
+ sdbDevStExtendedNames Integer32,
+ sdbDevStPeakDuration MilliSecond,
+ sdbDevStFixedOutletDelay MilliSecond,
+ sdbDevStPowerSaverMode Second,
+ sdbDevStOutletPowerUpMode Integer32,
+ sdbDevStMaximumTemperature Integer32,
+ sdbDevStDisplayOrientation Integer32,
+ sdbDevStLocalAlertReset Integer32,
+ sdbDevStCurrentDropDetection Integer32,
+ sdbDevStUsbMode Integer32
+ }
+
+sdbDevStAutoResetAlerts OBJECT-TYPE
+ SYNTAX Integer32 (0..65535)
+ UNITS "seconds"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Auto reset alerts configuration.
+ If set to 0 the auto reset alerts feature is disabled. If set to a
+ value greater then 0, the auto reset alerts feature is enabled and
+ alerts will get cleared after the configured amount of seconds since
+ the last alert condition have passed."
+ ::= { sdbDevStEntry 2 }
+
+sdbDevStExtendedNames OBJECT-TYPE
+ SYNTAX
+ INTEGER {
+ disabled(0),
+ enabled(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Use original or longer names for inputs, outlets and sensors."
+ ::= { sdbDevStEntry 3 }
+
+sdbDevStPeakDuration OBJECT-TYPE
+ SYNTAX MilliSecond (0..65535)
+ UNITS "ms"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Amount of ms a current peak should last before an alert is raised."
+ ::= { sdbDevStEntry 4 }
+
+sdbDevStFixedOutletDelay OBJECT-TYPE
+ SYNTAX MilliSecond (100..65535)
+ UNITS "ms"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Minimal delay between two successive relay switches in milliseconds.
+ Minimal delay is 100 ms. Will always be respected!"
+ ::= { sdbDevStEntry 5 }
+
+sdbDevStPowerSaverMode OBJECT-TYPE
+ SYNTAX Second (0 | 10 | 60 | 120 | 240)
+ UNITS "s"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Set backlight on time in seconds.
+ 0 keeps display always on.
+ Note that keeping the backlight on may decrease luminosity over time."
+ ::= { sdbDevStEntry 6 }
+
+sdbDevStOutletPowerUpMode OBJECT-TYPE
+ SYNTAX
+ INTEGER {
+ off(0), -- off
+ sameState(1), -- same state as at power down
+ sameStateDelayed(2) -- same state as at power down but delayed by
+ -- individual delay timer.
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Behaviour of outlets on power-up."
+ ::= { sdbDevStEntry 7 }
+
+sdbDevStMaximumTemperature OBJECT-TYPE
+ SYNTAX Integer32 (0..99)
+ UNITS "degrees Celsius"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Maximum temperature threshold
+ An alert will be generated whenever the temperature is above this
+ value. Zero means disabled."
+ ::= { sdbDevStEntry 8 }
+
+sdbDevStDisplayOrientation OBJECT-TYPE
+ SYNTAX
+ INTEGER {
+ noDisplay(0),
+ verticalDisplayOnTop(1),
+ verticalDisplayUpsideDown(2),
+ horizontalDisplayAtLeft(3),
+ horizontalDisplayAtRight(4)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Display orientation."
+ ::= { sdbDevStEntry 9 }
+
+sdbDevStLocalAlertReset OBJECT-TYPE
+ SYNTAX
+ INTEGER {
+ notAllowed(0),
+ allowed(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Allow alerts to be reset locally on device by pushing one of the
+ buttons."
+ ::= { sdbDevStEntry 10 }
+
+sdbDevStCurrentDropDetection OBJECT-TYPE
+ SYNTAX
+ INTEGER {
+ off(0),
+ inputsOnly(1),
+ outletsOnly(2),
+ inputsAndOutlets(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enables the current drop detection function."
+ ::= { sdbDevStEntry 11 }
+
+sdbDevStUsbMode OBJECT-TYPE
+ SYNTAX
+ INTEGER {
+ usbDisabled(0),
+ onlyFirmwareUpdates(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Allow the USB port to be used for specific tasks"
+ ::= { sdbDevStEntry 13 }
+
+sdbDevInTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SdbDevInEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table containing information of inputs of devices connected to the
+ databus."
+ ::= { sdbDevInput 1 }
+
+sdbDevInEntry OBJECT-TYPE
+ SYNTAX SdbDevInEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Inputs entry containing objects of an input of a particular databus
+ device.
+ Note that this table has two indexes. sdbDevIdIndex to identify a
+ particular device and sdbDevInIndex to identify a particular input
+ of the device identified by sdbDevIdIndex."
+ INDEX {
+ sdbDevIdIndex,
+ sdbDevInIndex
+ }
+ ::= { sdbDevInTable 1 }
+
+SdbDevInEntry ::=
+ SEQUENCE {
+ sdbDevInIndex Integer32,
+ sdbDevInKWhTotal KiloWattHour,
+ sdbDevInKWhSubtotal KiloWattHour,
+ sdbDevInPowerFactor CentiPercent,
+ sdbDevInActualCurrent CentiAmpere,
+ sdbDevInPeakCurrent CentiAmpere,
+ sdbDevInActualVoltage CentiVolt,
+ sdbDevInMinVoltage CentiVolt,
+ sdbDevInPowerVoltAmpere Integer32,
+ sdbDevInPowerWatt Integer32,
+ sdbDevInMaxAmps CentiAmpere,
+ sdbDevInCTRatio Integer32,
+ sdbDevInName DisplayString,
+ sdbDevInZeroKWhSubtotal Integer32
+ }
+
+sdbDevInIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..48)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A unique value for each input. Its value ranges between 1 and the
+ value of sdbDevCfPhases."
+ ::= { sdbDevInEntry 1 }
+
+sdbDevInKWhTotal OBJECT-TYPE
+ SYNTAX KiloWattHour
+ UNITS "kWh"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total kWh value of an input. This value can not be reset."
+ ::= { sdbDevInEntry 2 }
+
+sdbDevInKWhSubtotal OBJECT-TYPE
+ SYNTAX KiloWattHour
+ UNITS "kWh"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Subtotal kWh value of an input. This value can be reset."
+ ::= { sdbDevInEntry 3 }
+
+sdbDevInPowerFactor OBJECT-TYPE
+ SYNTAX CentiPercent
+ UNITS "%"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Power factor of input.
+ The power factor of an AC power system is defined as the ratio of the
+ real or active power to the apparent power and is a number between 0
+ and 1. This value is expressed as a percentage between 0% and 100%."
+ ::= { sdbDevInEntry 4 }
+
+sdbDevInActualCurrent OBJECT-TYPE
+ SYNTAX CentiAmpere
+ UNITS "A"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Actual apparent, RMS current."
+ ::= { sdbDevInEntry 5 }
+
+sdbDevInPeakCurrent OBJECT-TYPE
+ SYNTAX CentiAmpere
+ UNITS "A"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Peak apparent, RMS current.
+ Highest value since last reset of the alerts."
+ ::= { sdbDevInEntry 6 }
+
+sdbDevInActualVoltage OBJECT-TYPE
+ SYNTAX CentiVolt
+ UNITS "V"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The actual voltage."
+ ::= { sdbDevInEntry 7 }
+
+sdbDevInMinVoltage OBJECT-TYPE
+ SYNTAX CentiVolt
+ UNITS "V"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "RMS voltage dip.
+ Lowest value since reset of alerts."
+ ::= { sdbDevInEntry 8 }
+
+sdbDevInPowerVoltAmpere OBJECT-TYPE
+ SYNTAX Integer32 (0..327680)
+ UNITS "VA"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Calculated apparent power."
+ ::= { sdbDevInEntry 9 }
+
+sdbDevInPowerWatt OBJECT-TYPE
+ SYNTAX Integer32 (0..327680)
+ UNITS "W"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Calculated real power."
+ ::= { sdbDevInEntry 10 }
+
+sdbDevInMaxAmps OBJECT-TYPE
+ SYNTAX CentiAmpere
+ UNITS "A"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Maximum current per input phase.
+ Should last at least sdbDevStPeakDuration ms before triggering an
+ alert."
+ ::= { sdbDevInEntry 11 }
+
+sdbDevInCTRatio OBJECT-TYPE
+ SYNTAX Integer32 (0..255)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The multiplier to use for the input CTs."
+ ::= { sdbDevInEntry 12 }
+
+sdbDevInName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..8))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "User configurable naming of inputs or phases."
+ ::= { sdbDevInEntry 13 }
+
+sdbDevInZeroKWhSubtotal OBJECT-TYPE
+ SYNTAX
+ INTEGER {
+ idle(0),
+ zero(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Reset input kWh subtotal counter of a single input to zero."
+ ::= { sdbDevInEntry 14 }
+
+sdbDevOutTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SdbDevOutEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table containing information of outlets of devices connected to the
+ databus."
+ ::= { sdbDevOutlet 1 }
+
+sdbDevOutEntry OBJECT-TYPE
+ SYNTAX SdbDevOutEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Outlets entry containing objects of an outlet of a particular databus
+ device.
+ Note that this table has two indexes. sdbDevIdIndex to identify a
+ particular device and sdbDevOutIndex to identify a particular outlet
+ of the device identified by sdbDevIdIndex."
+ INDEX {
+ sdbDevIdIndex,
+ sdbDevOutIndex
+ }
+ ::= { sdbDevOutTable 1 }
+
+SdbDevOutEntry ::=
+ SEQUENCE {
+ sdbDevOutIndex Integer32,
+ sdbDevOutName DisplayString
+ }
+
+sdbDevOutIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..48)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A unique value for each outlet. Its value ranges between 1 and the
+ value of sdbDevCfOutletsTotal."
+ ::= { sdbDevOutEntry 1 }
+
+sdbDevOutName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..8))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "User configurable naming of individual outlets."
+ ::= { sdbDevOutEntry 2 }
+
+sdbDevOutMtTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SdbDevOutMtEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table containing information of metered outlets of devices connected
+ to the databus."
+ ::= { sdbDevOutlet 2 }
+
+sdbDevOutMtEntry OBJECT-TYPE
+ SYNTAX SdbDevOutMtEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Metered outlets entry containing objects of a metered outlet of a
+ particular databus device.
+ Note that this table has two indexes. sdbDevIdIndex to identify a
+ particular device and sdbDevOutMtIndex to identify a particular outlet
+ of the device identified by sdbDevIdIndex."
+ INDEX {
+ sdbDevIdIndex,
+ sdbDevOutMtIndex
+ }
+ ::= { sdbDevOutMtTable 1 }
+
+SdbDevOutMtEntry ::=
+ SEQUENCE {
+ sdbDevOutMtIndex Integer32,
+ sdbDevOutMtKWhTotal KiloWattHour,
+ sdbDevOutMtKWhSubtotal KiloWattHour,
+ sdbDevOutMtPowerFactor CentiPercent,
+ sdbDevOutMtActualCurrent CentiAmpere,
+ sdbDevOutMtPeakCurrent CentiAmpere,
+ sdbDevOutMtActualVoltage CentiVolt,
+ sdbDevOutMtMaxAmps CentiAmpere,
+ sdbDevOutMtCTRatio Integer32,
+ sdbDevOutMtPowerVoltAmpere Integer32,
+ sdbDevOutMtPowerWatt Integer32
+ }
+
+sdbDevOutMtIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..48)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A unique value for each outlet. Its value ranges between 1 and the
+ value of sdbDevCfOutletsMetered."
+ ::= { sdbDevOutMtEntry 1 }
+
+sdbDevOutMtKWhTotal OBJECT-TYPE
+ SYNTAX KiloWattHour
+ UNITS "kWh"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total kWh value of an outlet. This value can not be reset."
+ ::= { sdbDevOutMtEntry 2 }
+
+sdbDevOutMtKWhSubtotal OBJECT-TYPE
+ SYNTAX KiloWattHour
+ UNITS "kWh"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Subotal kWh value of an outlet. This value can be reset."
+ ::= { sdbDevOutMtEntry 3 }
+
+sdbDevOutMtPowerFactor OBJECT-TYPE
+ SYNTAX CentiPercent
+ UNITS "%"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Power factor of outlet.
+ The power factor of an AC power system is defined as the ratio of the
+ real or active power to the apparent power and is a number between 0
+ and 1. This number is expressed as a percentage between 0% and 100%."
+ ::= { sdbDevOutMtEntry 4 }
+
+sdbDevOutMtActualCurrent OBJECT-TYPE
+ SYNTAX CentiAmpere
+ UNITS "A"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Actual apparent, RMS current."
+ ::= { sdbDevOutMtEntry 5 }
+
+sdbDevOutMtPeakCurrent OBJECT-TYPE
+ SYNTAX CentiAmpere
+ UNITS "A"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Peak apparent, RMS current.
+ Highest value since last reset of the alerts."
+ ::= { sdbDevOutMtEntry 6 }
+
+sdbDevOutMtActualVoltage OBJECT-TYPE
+ SYNTAX CentiVolt
+ UNITS "V"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Actual voltage on outlet."
+ ::= { sdbDevOutMtEntry 7 }
+
+sdbDevOutMtMaxAmps OBJECT-TYPE
+ SYNTAX CentiAmpere
+ UNITS "A"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Maximum current per outlet.
+ Should last at least sdbDevStPeakDuration ms before triggering an
+ alert."
+ ::= { sdbDevOutMtEntry 8 }
+
+sdbDevOutMtCTRatio OBJECT-TYPE
+ SYNTAX Integer32 (0..255)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The multiplier to use for the outlet CTs."
+ ::= { sdbDevOutMtEntry 9 }
+
+sdbDevOutMtPowerVoltAmpere OBJECT-TYPE
+ SYNTAX Integer32 (0..327680)
+ UNITS "VA"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Calculated apparent power."
+ ::= { sdbDevOutMtEntry 10 }
+
+sdbDevOutMtPowerWatt OBJECT-TYPE
+ SYNTAX Integer32 (0..327680)
+ UNITS "W"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Calculated real power."
+ ::= { sdbDevOutMtEntry 11 }
+
+sdbDevOutSwTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SdbDevOutSwEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table containing information of switched outlets of devices
+ connected to the databus."
+ ::= { sdbDevOutlet 3 }
+
+sdbDevOutSwEntry OBJECT-TYPE
+ SYNTAX SdbDevOutSwEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Switched outlets entry containing objects of a switched outlet of a
+ particular databus device.
+ Note that this table has two indexes. sdbDevIdIndex to identify a
+ particular device and sdbDevOutSwIndex to identify a particular outlet
+ of the device identified by sdbDevIdIndex."
+ INDEX {
+ sdbDevIdIndex,
+ sdbDevOutSwIndex
+ }
+ ::= { sdbDevOutSwTable 1 }
+
+SdbDevOutSwEntry ::=
+ SEQUENCE {
+ sdbDevOutSwIndex Integer32,
+ sdbDevOutSwCurrentState Integer32,
+ sdbDevOutSwScheduled Integer32,
+ sdbDevOutSwUnlock Integer32,
+ sdbDevOutSwIndividualOutletDelay Second,
+ sdbDevOutSwReboot Integer32
+ }
+
+sdbDevOutSwIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..48)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A unique value for each outlet. Its value ranges between 1 and the
+ value of sdbDevCfOutletsSwitched."
+ ::= { sdbDevOutSwEntry 1 }
+
+sdbDevOutSwCurrentState OBJECT-TYPE
+ SYNTAX
+ INTEGER {
+ off(0),
+ on(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The actual state of the outlet relay.
+ Note that Writing is only effective after setting sdbDevOutSwUnlock."
+ ::= { sdbDevOutSwEntry 2 }
+
+sdbDevOutSwScheduled OBJECT-TYPE
+ SYNTAX
+ INTEGER {
+ idle(0),
+ scheduled(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A one indicates pending activity; the switch delay has not yet
+ expired."
+ ::= { sdbDevOutSwEntry 3 }
+
+sdbDevOutSwUnlock OBJECT-TYPE
+ SYNTAX
+ INTEGER {
+ locked(0),
+ unlocked(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Switching and rebooting is unlocked for 10 seconds by writing a 1."
+ ::= { sdbDevOutSwEntry 4 }
+
+sdbDevOutSwIndividualOutletDelay OBJECT-TYPE
+ SYNTAX Second (0..65535)
+ UNITS "s"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Delay before an individual outlet switches on at power-up."
+ ::= { sdbDevOutSwEntry 5 }
+
+sdbDevOutSwReboot OBJECT-TYPE
+ SYNTAX
+ INTEGER {
+ idle(0),
+ reboot(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Reboot outlet relay if current state is on and outlet is unlocked;
+ The outlet will be turned on after 10 seconds."
+ ::= { sdbDevOutSwEntry 6 }
+
+sdbDevMeasuresTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SdbDevMeasuresEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table containing information of temperatures of devices connected to
+ the databus."
+ ::= { sdbDevSensor 1 }
+
+sdbDevMeasuresEntry OBJECT-TYPE
+ SYNTAX SdbDevMeasuresEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Device measures entry containing temperature information objects of a
+ particular databus device."
+ INDEX { sdbDevIdIndex }
+ ::= { sdbDevMeasuresTable 1 }
+
+SdbDevMeasuresEntry ::=
+ SEQUENCE {
+ sdbDevMsIntTemperature CentiCelsius,
+ sdbDevMsExtTemperature CentiCelsius,
+ sdbDevMsIntTemperaturePeak CentiCelsius,
+ sdbDevMsExtTemperaturePeak CentiCelsius
+ }
+
+sdbDevMsIntTemperature OBJECT-TYPE
+ SYNTAX CentiCelsius
+ UNITS "degrees Celsius"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Actual internal device temperature in deg C"
+ ::= { sdbDevMeasuresEntry 1 }
+
+sdbDevMsExtTemperature OBJECT-TYPE
+ SYNTAX CentiCelsius
+ UNITS "degrees Celsius"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Actual external device temperature sensor in deg C."
+ ::= { sdbDevMeasuresEntry 2 }
+
+sdbDevMsIntTemperaturePeak OBJECT-TYPE
+ SYNTAX CentiCelsius
+ UNITS "degrees Celsius"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Peak internal device temperature since last reset of alerts."
+ ::= { sdbDevMeasuresEntry 3 }
+
+sdbDevMsExtTemperaturePeak OBJECT-TYPE
+ SYNTAX CentiCelsius
+ UNITS "degrees Celsius"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Peak external device temperature since last reset of alerts."
+ ::= { sdbDevMeasuresEntry 4 }
+
+sdbDevSnsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SdbDevSnsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table containing information of sensors of devices connected to the
+ databus."
+ ::= { sdbDevSensor 2 }
+
+sdbDevSnsEntry OBJECT-TYPE
+ SYNTAX SdbDevSnsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Sensors entry containing objects of a sensor of a particular databus
+ device.
+ Note that this table has two indexes. sdbDevIdIndex to identify a
+ particular device and sdbDevSnsIndex to identify a particular sensor
+ of the device identified by sdbDevIdIndex."
+ INDEX {
+ sdbDevIdIndex,
+ sdbDevSnsIndex
+ }
+ ::= { sdbDevSnsTable 1 }
+
+SdbDevSnsEntry ::=
+ SEQUENCE {
+ sdbDevSnsIndex Integer32,
+ sdbDevSnsType DisplayString,
+ sdbDevSnsValue CentiValue,
+ sdbDevSnsName DisplayString
+ }
+
+sdbDevSnsIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..16)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A unique value for each sensor. Its value ranges between 1 and the
+ value of sdbDevCfSensors."
+ ::= { sdbDevSnsEntry 1 }
+
+sdbDevSnsType OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(1))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Type of connected sensor.
+ T = Temperature (C)
+ H = Humidity (%)
+ I = dry switch contact"
+ ::= { sdbDevSnsEntry 2 }
+
+sdbDevSnsValue OBJECT-TYPE
+ SYNTAX CentiValue (0..327680)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Value of connected sensor"
+ ::= { sdbDevSnsEntry 3 }
+
+sdbDevSnsName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..6))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "User definable name for sensors."
+ ::= { sdbDevSnsEntry 4 }
+
+-- ---------------------------------------------------------------------------------------------
+sdbDevPerformanceTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SdbDevPerformanceEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table containing information of sensors of devices connected to the
+ databus."
+ ::= { sdbDevPerformance 1 }
+
+sdbDevPerformanceEntry OBJECT-TYPE
+ SYNTAX SdbDevPerformanceEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Performance counters of a particular databus device.
+ Note that this table has two indexes. sdbDevIdIndex to identify a
+ particular device and sdbDevPerformanceIndex to identify a particular counter
+ of the device identified by sdbDevIdIndex."
+ INDEX {
+ sdbDevIdIndex,
+ sdbDevPerformanceIndex
+ }
+ ::= { sdbDevPerformanceTable 1 }
+
+SdbDevPerformanceEntry ::=
+ SEQUENCE {
+ sdbDevPerformanceIndex Integer32,
+ sdbDevPerformanceValue Integer32,
+ sdbDevPerformanceMax Integer32,
+ sdbDevPerformanceLimit Integer32,
+ sdbDevPerformanceName DisplayString
+ }
+
+sdbDevPerformanceIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..16)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A unique value for each counter. Its value ranges between 1 and 16."
+ ::= { sdbDevPerformanceEntry 1 }
+
+sdbDevPerformanceValue OBJECT-TYPE
+ SYNTAX Integer32 (0..16777215)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Value of counter"
+ ::= { sdbDevPerformanceEntry 2 }
+
+sdbDevPerformanceMax OBJECT-TYPE
+ SYNTAX Integer32 (0..16777215)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Max of counter"
+ ::= { sdbDevPerformanceEntry 3 }
+
+sdbDevPerformanceLimit OBJECT-TYPE
+ SYNTAX Integer32 (0..16777215)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Limit of counter"
+ ::= { sdbDevPerformanceEntry 4 }
+
+sdbDevPerformanceName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..12))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "User definable name for counter."
+ ::= { sdbDevPerformanceEntry 5 }
+
+-- ---------------------------------------------------------------------------------------------
+
+sdbDevPerformanceResetTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SdbDevPerformanceResetEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table containing the last reset reason of the device"
+ ::= { sdbDevPerformance 2 }
+
+sdbDevPerformanceResetEntry OBJECT-TYPE
+ SYNTAX SdbDevPerformanceResetEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Setting entry containing settings objects of a particular databus
+ device."
+ INDEX { sdbDevIdIndex }
+ ::= { sdbDevPerformanceResetTable 1 }
+
+SdbDevPerformanceResetEntry ::=
+ SEQUENCE {
+ sdbDevPerformanceResetReason DisplayString,
+ sdbDevResetUptime Unsigned32
+ }
+
+sdbDevPerformanceResetReason OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..64))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Last reset reason."
+ ::= { sdbDevPerformanceResetEntry 1 }
+
+sdbDevResetUptime OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Uptime before last reset"
+ ::= { sdbDevPerformanceResetEntry 2 }
+
+-- ---------------------------------------------------------------------------------------------
+
+sdbDevSsDeviceStatusCodeChanged NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Device status code changed.
+
+ OBJECTS {
+ sdbDevSsDeviceStatusCode
+ }"
+ ::= { sdbMIBNotifications 1 }
+
+sdbDevSsTemperatureAlertDetected NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Temperature alert detected.
+
+ Internal temperature alert:
+ OBJECTS {
+ sdbDevSsTemperatureAlert,
+ sdbDevMsIntTemperature,
+ sdbDevMsIntTemperaturePeak
+ }
+
+ External analog temperature alert:
+ OBJECTS {
+ sdbDevSsTemperatureAlert,
+ sdbDevMsExtTemperature,
+ sdbDevMsExtTemperaturePeak
+ }
+
+ External digital temperature alert:
+ OBJECTS {
+ sdbDevSsTemperatureAlert,
+ sdbDevSnsValue
+ }"
+ ::= { sdbMIBNotifications 2 }
+
+sdbDevSsInputCurrentAlertDetected NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Input current alert detected.
+
+ OBJECTS {
+ sdbDevSsInputCurrentAlert,
+ sdbDevInActualCurrent
+ }"
+ ::= { sdbMIBNotifications 3 }
+
+sdbDevSsOutletCurrentAlertDetected NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Outlet current alert detected.
+
+ OBJECTS {
+ sdbDevSsOutletCurrentAlert,
+ sdbDevOutMtActualCurrent
+ }"
+ ::= { sdbMIBNotifications 4 }
+
+sdbDevSsInputVoltageAlertDetected NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Input voltage alert detected.
+
+ OBJECTS {
+ sdbDevSsInputVoltageAlert,
+ sdbDevInActualVoltage
+ }"
+ ::= { sdbMIBNotifications 5 }
+
+sdbDevSsOutletCurrentDropAlertDetected NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Outlet current drop alert detected.
+
+ OBJECTS {
+ sdbDevSsOutletCurrentDropAlert,
+ sdbDevOutMtActualCurrent
+ }"
+ ::= { sdbMIBNotifications 6 }
+
+sdbDevSsInputCurrentDropAlertDetected NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Input current drop alert detected.
+
+ OBJECTS {
+ sdbDevSsInputCurrentDropAlert,
+ sdbDevInActualCurrent
+ }"
+ ::= { sdbMIBNotifications 7 }
+
+sdbDevSsSensorChangeAlertDetected NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Sensor channel change alert detected.
+
+ OBJECTS {
+ sdbDevSsSensorChangeAlert
+ }"
+ ::= { sdbMIBNotifications 8 }
+
+sdbMgmtStsRingStateChanged NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Ring state changed.
+
+ Ring state changded to open:
+ OBJECTS {
+ sdbMgmtStsRingState,
+ sdbMgmtStsRingBreachIndex
+ }
+
+ Ring state changded to closed:
+ OBJECTS {
+ sdbMgmtStsRingState
+ }"
+ ::= { sdbMIBNotifications 9 }
+
+sdbDevSsOutletVoltageDropAlertDetected NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Outlet voltage drop alert detected.
+
+ OBJECTS {
+ sdbDevSsOutletVoltageDropAlert,
+ sdbDevOutMtActualVoltage
+ }"
+ ::= { sdbMIBNotifications 10 }
+
+
+sdbMIBCompliance MODULE-COMPLIANCE
+ STATUS current
+ DESCRIPTION
+ "The requirements for conformance to the SCHLEIFENBAUER-DATABUS-MIB."
+ MODULE SCHLEIFENBAUER-DATABUS-MIB
+ GROUP sdbMIBNotificationGroup
+ DESCRIPTION
+ "The notification group."
+ GROUP sdbMIBDevSensorGroup
+ DESCRIPTION
+ "The sensors group."
+ GROUP sdbMIBDevOutGroup
+ DESCRIPTION
+ "The outlet group."
+ GROUP sdbMIBDevOutMtGroup
+ DESCRIPTION
+ "The outletMetering group."
+ GROUP sdbMIBDevOutSwGroup
+ DESCRIPTION
+ "The outletSwitched group."
+ GROUP sdbMIBDevInGroup
+ DESCRIPTION
+ "The inputMeasures group."
+ GROUP sdbMIBDevStGroup
+ DESCRIPTION
+ "The settings group."
+ GROUP sdbMIBDevSsGroup
+ DESCRIPTION
+ "The systemStatus group."
+ GROUP sdbMIBDevCfGroup
+ DESCRIPTION
+ "The configuration group."
+ GROUP sdbMIBDevIdGroup
+ DESCRIPTION
+ "The identification group."
+ GROUP sdbMIBDevRsGroup
+ DESCRIPTION
+ "resettable attributes in device"
+ GROUP sdbMIBMgmtStatusGroup
+ DESCRIPTION
+ "The databus management status group."
+ GROUP sdbMIBMgmtControlGroup
+ DESCRIPTION
+ "The databus management control group."
+ GROUP sdbMIBDevPerformanceGroup
+ DESCRIPTION
+ "The databus management control group."
+ ::= { sdbMIBCompliances 1 }
+
+sdbMIBNotificationGroup NOTIFICATION-GROUP
+ NOTIFICATIONS {
+ sdbDevSsDeviceStatusCodeChanged,
+ sdbDevSsTemperatureAlertDetected,
+ sdbDevSsInputCurrentAlertDetected,
+ sdbDevSsOutletCurrentAlertDetected,
+ sdbDevSsInputVoltageAlertDetected,
+ sdbDevSsOutletCurrentDropAlertDetected,
+ sdbDevSsInputCurrentDropAlertDetected,
+ sdbDevSsSensorChangeAlertDetected,
+ sdbMgmtStsRingStateChanged,
+ sdbDevSsOutletVoltageDropAlertDetected
+ }
+ STATUS current
+ DESCRIPTION
+ "A collection of notifications."
+ ::= { sdbMIBGroups 1 }
+
+sdbMIBDevIdGroup OBJECT-GROUP
+ OBJECTS {
+ sdbDevIdSPDMVersion,
+ sdbDevIdFirmwareVersion,
+ sdbDevIdSalesOrderNumber,
+ sdbDevIdProductId,
+ sdbDevIdSerialNumber,
+ sdbDevIdHardwareAddress,
+ sdbDevIdUnitAddress,
+ sdbDevIdName,
+ sdbDevIdLocation,
+ sdbDevIdVanityTag,
+ sdbDevIdMacAddress,
+ sdbDevIdBuildNumber,
+ sdbDevIdDeviceType,
+ sdbDevIdLocateUnit
+ }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects providing identification information about the
+ device."
+ ::= { sdbMIBGroups 3 }
+
+sdbMIBDevCfGroup OBJECT-GROUP
+ OBJECTS {
+ sdbDevCfPhases,
+ sdbDevCfOutletsTotal,
+ sdbDevCfOutletsSwitched,
+ sdbDevCfOutletsMetered,
+ sdbDevCfMaximumLoad,
+ sdbDevCfSensors
+ }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects providing configuration information about the
+ device."
+ ::= { sdbMIBGroups 4 }
+
+sdbMIBDevSsGroup OBJECT-GROUP
+ OBJECTS {
+ sdbDevSsDeviceStatusCode,
+ sdbDevSsTemperatureAlert,
+ sdbDevSsInputCurrentAlert,
+ sdbDevSsOutletCurrentAlert,
+ sdbDevSsInputVoltageAlert,
+ sdbDevSsOutletCurrentDropAlert,
+ sdbDevSsInputCurrentDropAlert,
+ sdbDevSsSensorChangeAlert,
+ sdbDevSsOutletVoltageDropAlert
+ }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects providing status information about the
+ device."
+ ::= { sdbMIBGroups 5 }
+
+sdbMIBDevRsGroup OBJECT-GROUP
+ OBJECTS {
+ sdbDevRsResetAlerts,
+ sdbDevRsResetPeaksAndDips,
+ sdbDevRsReboot,
+ sdbDevRsZeroInputKWhSubtotal,
+ sdbDevRsZeroOutletKWhSubtotal
+ }
+ STATUS current
+ DESCRIPTION
+ "Groups resettable attributes op the device."
+ ::= { sdbMIBGroups 6 }
+
+sdbMIBDevStGroup OBJECT-GROUP
+ OBJECTS {
+ sdbDevStAutoResetAlerts,
+ sdbDevStExtendedNames,
+ sdbDevStPeakDuration,
+ sdbDevStLocalAlertReset,
+ sdbDevStFixedOutletDelay,
+ sdbDevStPowerSaverMode,
+ sdbDevStOutletPowerUpMode,
+ sdbDevStMaximumTemperature,
+ sdbDevStDisplayOrientation,
+ sdbDevStCurrentDropDetection,
+ sdbDevStUsbMode
+ }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects providing the actual settings about the
+ device."
+ ::= { sdbMIBGroups 7 }
+
+sdbMIBDevInGroup OBJECT-GROUP
+ OBJECTS {
+ sdbDevInKWhTotal,
+ sdbDevInKWhSubtotal,
+ sdbDevInPowerFactor,
+ sdbDevInActualCurrent,
+ sdbDevInPeakCurrent,
+ sdbDevInActualVoltage,
+ sdbDevInMinVoltage,
+ sdbDevInPowerVoltAmpere,
+ sdbDevInPowerWatt,
+ sdbDevInMaxAmps,
+ sdbDevInCTRatio,
+ sdbDevInName,
+ sdbDevInZeroKWhSubtotal
+ }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects providing the actual input measurements of the
+ device."
+ ::= { sdbMIBGroups 8 }
+
+sdbMIBDevOutGroup OBJECT-GROUP
+ OBJECTS {
+ sdbDevOutName
+ }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects providing the actual outlet measurements of
+ the device."
+ ::= { sdbMIBGroups 9 }
+
+sdbMIBDevOutMtGroup OBJECT-GROUP
+ OBJECTS {
+ sdbDevOutMtKWhTotal,
+ sdbDevOutMtKWhSubtotal,
+ sdbDevOutMtPowerFactor,
+ sdbDevOutMtActualCurrent,
+ sdbDevOutMtPeakCurrent,
+ sdbDevOutMtActualVoltage,
+ sdbDevOutMtMaxAmps,
+ sdbDevOutMtCTRatio,
+ sdbDevOutMtPowerVoltAmpere,
+ sdbDevOutMtPowerWatt
+ }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects providing the actual outlet measurements of
+ the device."
+ ::= { sdbMIBGroups 10 }
+
+sdbMIBDevOutSwGroup OBJECT-GROUP
+ OBJECTS {
+ sdbDevOutSwCurrentState,
+ sdbDevOutSwScheduled,
+ sdbDevOutSwUnlock,
+ sdbDevOutSwIndividualOutletDelay,
+ sdbDevOutSwReboot
+ }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects providing the actual outlet measurements of
+ the device."
+ ::= { sdbMIBGroups 11 }
+
+sdbMIBDevSensorGroup OBJECT-GROUP
+ OBJECTS {
+ sdbDevSnsType,
+ sdbDevSnsValue,
+ sdbDevSnsName,
+ sdbDevMsIntTemperature,
+ sdbDevMsExtTemperature,
+ sdbDevMsIntTemperaturePeak,
+ sdbDevMsExtTemperaturePeak
+ }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects providing the actual environmental
+ measurements of the device."
+ ::= { sdbMIBGroups 12 }
+
+sdbMIBMgmtStatusGroup OBJECT-GROUP
+ OBJECTS {
+ sdbMgmtStsDevices,
+ sdbMgmtStsAddressableDevices,
+ sdbMgmtStsNewDevices,
+ sdbMgmtStsDuplicateDevices,
+ sdbMgmtStsRingState,
+ sdbMgmtStsRingBreachIndex
+ }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects providing management status information about
+ the databus."
+ ::= { sdbMIBGroups 13 }
+
+sdbMIBMgmtControlGroup OBJECT-GROUP
+ OBJECTS {
+ sdbMgmtCtrlScan,
+ sdbMgmtCtrlRenumberAllFromN,
+ sdbMgmtCtrlRenumberZeros,
+ sdbMgmtCtrlDevUnitAddress,
+ sdbMgmtCtrlDevHardwareAddress,
+ sdbMgmtCtrlDevIsNew,
+ sdbMgmtCtrlDevIsDuplicate
+ }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects providing management control information about
+ the databus."
+ ::= { sdbMIBGroups 14 }
+
+sdbMIBDevPerformanceGroup OBJECT-GROUP
+ OBJECTS {
+ sdbDevPerformanceValue,
+ sdbDevPerformanceMax,
+ sdbDevPerformanceLimit,
+ sdbDevPerformanceName,
+ sdbDevPerformanceResetReason,
+ sdbDevResetUptime
+ }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects providing performance information about the MCU"
+ ::= { sdbMIBGroups 15 }
+
+END
diff --git a/MIBS/schleifenbauer/SCHLEIFENBAUER-PRODUCTS-MIB b/MIBS/schleifenbauer/SCHLEIFENBAUER-PRODUCTS-MIB
new file mode 100644
index 0000000..4153300
--- /dev/null
+++ b/MIBS/schleifenbauer/SCHLEIFENBAUER-PRODUCTS-MIB
@@ -0,0 +1,51 @@
+-------------------------------------------------------------------------------
+--
+-- SCHLEIFENBAUER-PRODUCTS-MIB.txt: Schleifenbauer Product Object Identifier Assignments
+--
+-- October 2015, Marco Veeneman
+--
+-- Copyright (c) 2015 by Schleifenbauer Holding BV
+-- All rights reserved.
+--
+-------------------------------------------------------------------------------
+
+SCHLEIFENBAUER-PRODUCTS-MIB DEFINITIONS ::= BEGIN
+
+IMPORTS
+ MODULE-IDENTITY
+ FROM SNMPv2-SMI
+ schleifenbauerProducts,
+ schleifenbauerModules
+ FROM SCHLEIFENBAUER-SMI;
+
+schleifenbauerProductsMIB MODULE-IDENTITY
+ LAST-UPDATED
+ "201510230000Z" -- October 23th, 2015
+ ORGANIZATION
+ "Schleifenbauer Engineering"
+ CONTACT-INFO
+ "Schleifenbauer Engineering
+ Alain Schuermans
+ Chief Technology Officer
+ Turnhoutseweg 22
+ 5541 NX Reusel
+ The Netherlands
+ t. +31 73 5230256
+ f. +31 73 5212383
+ alain@schleifenbauer.eu
+ www.schleifenbauer.eu"
+ DESCRIPTION
+ "TODO: description.
+
+ Copyright (c) 2015 by Schleifenbauer Products BV
+ "
+ REVISION
+ "201510230000Z" -- October 23th, 2015
+ DESCRIPTION
+ "The initial revision of this MIB module"
+ ::= { schleifenbauerModules 2}
+
+hpdu OBJECT IDENTIFIER ::= { schleifenbauerProducts 1 }
+dpm3 OBJECT IDENTIFIER ::= { schleifenbauerProducts 2 }
+
+END
diff --git a/MIBS/schleifenbauer/SCHLEIFENBAUER-SMI b/MIBS/schleifenbauer/SCHLEIFENBAUER-SMI
new file mode 100644
index 0000000..ca44c83
--- /dev/null
+++ b/MIBS/schleifenbauer/SCHLEIFENBAUER-SMI
@@ -0,0 +1,68 @@
+-------------------------------------------------------------------------------
+--
+-- SCHLEIFENBAUER-DATABUS-MIB.txt: Schleifenbauer Enterprise Structure of Management Information
+--
+-- October 2015, Marco Veeneman
+--
+-- Copyright (c) 2015 by Schleifenbauer Holding BV
+-- All rights reserved.
+--
+-------------------------------------------------------------------------------
+
+SCHLEIFENBAUER-SMI DEFINITIONS ::= BEGIN
+
+IMPORTS
+ MODULE-IDENTITY,
+ OBJECT-IDENTITY,
+ enterprises
+ FROM SNMPv2-SMI;
+
+schleifenbauer MODULE-IDENTITY
+ LAST-UPDATED
+ "201510230000Z" -- October 23th, 2015
+ ORGANIZATION
+ "Schleifenbauer Engineering"
+ CONTACT-INFO
+ "Schleifenbauer Engineering
+ Alain Schuermans
+ Chief Technology Officer
+ Rietwaard 15
+ 5236 WC ‘s-Hertogenbosch
+ The Netherlands
+ t +31 (0)73 52 30256
+ f +31 (0)73 521 23 83
+ alain@schleifenbauer.eu
+ www.schleifenbauer.eu"
+ DESCRIPTION
+ "The Structure of Management Information for the Schleifenbauer
+ enterprise.
+
+ Copyright (c) 2015 by Schleifenbauer Products BV"
+ REVISION
+ "201510230000Z" -- October 23th, 2015
+ DESCRIPTION
+ "The initial revision of this MIB module"
+ ::= { enterprises 31034 }
+
+schleifenbauerProducts OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "schleifenbauerProducts is the root OBJECT IDENTIFIER from which
+ sysObjectId values are assigned. Acutal values are defined in
+ SCHLEIFENBAUER-PRODUCTS-MIB."
+ ::= { schleifenbauer 11 }
+
+schleifenbauerMgmt OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "schleifenbauerMgmt is the main subtree for new mib development."
+ ::= { schleifenbauer 12 }
+
+schleifenbauerModules OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "schleifenbauerModules provides a root object identifier from which
+ MODULE-IDENTITY values may be assigned."
+ ::= { schleifenbauer 13 }
+
+END