summaryrefslogtreecommitdiff
path: root/MIBS/siae/SIAE-ACM-STATISTICS-MIB
diff options
context:
space:
mode:
authorDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
committerDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
commit98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch)
tree9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/siae/SIAE-ACM-STATISTICS-MIB
downloadmibs-main.tar.gz
mibs-main.zip
Initial commitHEADmain
Diffstat (limited to 'MIBS/siae/SIAE-ACM-STATISTICS-MIB')
-rw-r--r--MIBS/siae/SIAE-ACM-STATISTICS-MIB616
1 files changed, 616 insertions, 0 deletions
diff --git a/MIBS/siae/SIAE-ACM-STATISTICS-MIB b/MIBS/siae/SIAE-ACM-STATISTICS-MIB
new file mode 100644
index 0000000..0da4dc7
--- /dev/null
+++ b/MIBS/siae/SIAE-ACM-STATISTICS-MIB
@@ -0,0 +1,616 @@
+-- ----------------------------------------------------------------------------
+--
+-- SIAE MICROELETTRONICA s.p.a.
+--
+-- Via Michelangelo Buonarroti, 21
+-- 20093 - Cologno Monzese
+-- Milano
+-- ITALY
+--
+-- ----------------------------------------------------------------------------
+-- ----------------------------------------------------------------------------
+
+SIAE-ACM-STATISTICS-MIB
+ DEFINITIONS ::= BEGIN
+
+ IMPORTS
+ MODULE-IDENTITY, OBJECT-TYPE,
+ Counter32, Integer32, Unsigned32
+ FROM SNMPv2-SMI
+ TEXTUAL-CONVENTION,
+ DisplayString, RowStatus
+ FROM SNMPv2-TC
+ siaeMib
+ FROM SIAE-TREE-MIB
+ AlarmStatus, AlarmSeverityCode
+ FROM SIAE-ALARM-MIB;
+
+ acmStats MODULE-IDENTITY
+ LAST-UPDATED "201411050000Z"
+ ORGANIZATION "SIAE MICROELETTRONICA spa"
+ CONTACT-INFO
+ "SIAE MICROELETTONICA s.p.a.
+ Via Michelangelo Buonarroti, 21
+ 20093 - Cologno Monzese
+ Milano - ITALY
+ Phone : +39-02-27325-1
+ E-mail: tbd@siaemic.com
+ "
+ DESCRIPTION
+ "Adaptive Code Modulation (ACM) Statistics (Performance Monitoring)
+ "
+ REVISION "201411050000Z"
+ DESCRIPTION
+ "MIB version 01.00.01
+ - Added ACM profilea 4096 QAM and 4096QAM strong
+ (changed AcmProfile TEXTUAL-CONVENTION)
+ "
+ REVISION "201402110000Z"
+ DESCRIPTION
+ "Initial version 01.00.00
+ "
+ ::= { siaeMib 75 }
+
+----------------------------------------------------------------------------------
+-- Textual Conventions
+----------------------------------------------------------------------------------
+
+ AcmProfile ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "List of supported ACM profiles.
+ "
+ SYNTAX INTEGER {
+ unavailable (1), -- This is a virtual profile needed to
+ -- create a row in the table of counters
+ -- in order to count seconds with modem
+ -- not locked.
+ downshift (2), -- This is a virtual profile needed to
+ -- create a row in the table of counters
+ -- in order to count transitions towards
+ -- lower profiles.
+ upshift (3), -- This is a virtual profile needed to
+ -- create a row in the table of counters
+ -- in order to count transitions towards
+ -- upper profiles.
+ acmBPSKstrong (4),
+ acmBPSK (5),
+ acm4QAMstrong (6),
+ acm4QAM (7),
+ acm8PSKstrong (8),
+ acm8PSK (9),
+ acm16QAMstrong (10),
+ acm16QAM (11),
+ acm32QAMstrong (12),
+ acm32QAM (13),
+ acm64QAMstrong (14),
+ acm64QAM (15),
+ acm128QAMstrong (16),
+ acm128QAM (17),
+ acm256QAMstrong (18),
+ acm256QAM (19),
+ acm512QAMstrong (20),
+ acm512QAM (21),
+ acm1024QAMstrong (22),
+ acm1024QAM (23),
+ acm2048QAMstrong (24),
+ acm2048QAM (25),
+ acm4096QAMstrong (26),
+ acm4096QAM (27)
+ }
+
+----------------------------------------------------------------------------------
+-- object identifier inside the module
+----------------------------------------------------------------------------------
+
+----------------------------------------------------------------------------------
+-- acmStats (PERFORMANCE MONITORING ACM) Group
+----------------------------------------------------------------------------------
+--
+-- The following objects are used to manage the ACM counters.
+-- The objects of this group are meaningful only if radioEquipAcmEngineEnable
+-- is equal to "enable".
+--
+----------------------------------------------------------------------------------
+
+------ Beginning --------------------------------------------------------------
+
+ acmsMibVersion OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Numerical version of this module.
+ The string version of this MIB have the following format:
+ XX.YY.ZZ
+ so, for example, the value 1 should be interpreted as 00.00.01
+ and the value 10001 should be interpreted as 01.00.01."
+ ::= {acmStats 1}
+
+--
+-- TERMINATION POINT LINK TABLE
+--
+
+--
+------- The following table contains the records used to manage the P.M.
+
+------- Begin of acmsTpLinkTable
+--
+ acmsTpLinkTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AcmsTpLinkRecord
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table with ACM Termination Point of the radio links.
+ This table contains object to activate and deactivate the
+ buildup of counters.
+ "
+ ::= {acmStats 2}
+
+ acmsTpLinkRecord OBJECT-TYPE
+ SYNTAX AcmsTpLinkRecord
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry of acmsTpLinkTable.
+ "
+ INDEX {acmsTpLinkId, acmsTpLinkPolId}
+ ::= {acmsTpLinkTable 1}
+
+ AcmsTpLinkRecord ::=
+ SEQUENCE {
+ acmsTpLinkId Integer32,
+ acmsTpLinkPolId Integer32,
+ acmsTpLinkStartStop INTEGER,
+ acmsTpLinkLabel DisplayString,
+ acmsTpLinkRowStatus RowStatus
+ }
+
+ acmsTpLinkId OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This object identifies the Radio link.
+ "
+ ::= {acmsTpLinkRecord 1}
+
+ acmsTpLinkPolId OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This object identifies the Radio link polarization for XPIC
+ configuration. In non XPIC link this object should be 1.
+ "
+ ::= {acmsTpLinkRecord 2}
+
+ acmsTpLinkStartStop OBJECT-TYPE
+ SYNTAX INTEGER {
+ start (1),
+ stop (2)
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object is used to start and to stop the statistic
+ (Perfomance Monitoring) counter evaluation.
+ "
+ DEFVAL {stop}
+ ::= {acmsTpLinkRecord 3}
+
+ acmsTpLinkLabel OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..31))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "ASCII string used to identify the ACM Termination Point.
+ "
+ ::= {acmsTpLinkRecord 4}
+
+ acmsTpLinkRowStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Status of this row of acmsTpLinkTable.
+
+ When set to notInService, associated acmsTpProfileTable
+ rows may be added, deleted and modified.
+
+ When an attempt is made to set acmsTpLinkRowStatus to
+ active, there is at least a row in acmsTpProfileTable with
+ first index equal to acmsTpLinkId. Otherwise, the error
+ inconsistentValue is returned to the set attempt.
+
+ The creation of a row in this table, creates a row with the
+ same index in of acmsTpMaintTable.
+
+ The deletion of a row in this table, deletes a row with the
+ same index in of acmsTpMaintTable.
+
+ If this object is set to destroy, must not be no rows in
+ acmsTpProfileTable associated by acmsTpLinkId to the row
+ that is being deleted, otherwise, the error inconsistentValue
+ is returned to the set attempt. Hence, profile instances must
+ be deleted before this link instance.
+ "
+ ::= {acmsTpLinkRecord 5}
+
+--
+------- End of acmsTpLinkTable
+
+--
+-- PROFILE TABLE
+--
+
+------- Begin of acmsTpProfileTable
+--
+ acmsTpProfileTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AcmsTpProfileRecord
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "ACM Termination Point Thresholds Class table.
+ Table with AcmsTpProfileRecord records.
+ This table contains alarms and related thresholds to notify them
+ within a specific time interval.
+ "
+ ::= {acmStats 3}
+
+ acmsTpProfileRecord OBJECT-TYPE
+ SYNTAX AcmsTpProfileRecord
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry of acmsTpLinkTable.
+ Several instances (a instance for each ACM profile supported by
+ the radio system) of this record is created on creation of
+ acmsTpLinkTable.
+ "
+ INDEX {acmsTpLinkId, acmsTpLinkPolId, acmsTpProfileId}
+ ::= {acmsTpProfileTable 1}
+
+ AcmsTpProfileRecord ::=
+ SEQUENCE {
+ acmsTpProfileId AcmProfile,
+ acmsTpProfile15mAlarm AlarmStatus,
+ acmsTpProfile24hAlarm AlarmStatus,
+ acmsTpProfile15mThreshold Integer32,
+ acmsTpProfile24hThreshold Integer32,
+ acmsTpProfileRowStatus RowStatus
+ }
+
+ acmsTpProfileId OBJECT-TYPE
+ SYNTAX AcmProfile
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This object identifies the ACM profile of the radio system.
+ "
+ ::= {acmsTpProfileRecord 1}
+
+ acmsTpProfile15mAlarm OBJECT-TYPE
+ SYNTAX AlarmStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "If acmsCounteValue crosses the threshold acmsTpProfile15mThreshold,
+ this alarm is notified.
+ "
+ ::= {acmsTpProfileRecord 2}
+
+ acmsTpProfile24hAlarm OBJECT-TYPE
+ SYNTAX AlarmStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "If acmsCounteValue crosses the threshold acmsTpProfile24hThreshold,
+ this alarm is notified.
+ "
+ ::= {acmsTpProfileRecord 3}
+
+ acmsTpProfile15mThreshold OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Number of seconds within a 15 minutes interval to set
+ acmsTpProfile15mAlarm. The special value 0 turn off the alarm.
+
+ For downshift and upshift profiles, this threshold reports
+ the number of times a profile must be changed within a 15 minutes
+ interval to set acmsTpProfile15mAlarm.
+ "
+ ::= {acmsTpProfileRecord 4}
+
+ acmsTpProfile24hThreshold OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Number of seconds within a 24 hours interval to set
+ acmsTpProfile24hAlarm. The special value 0 turn off the alarm.
+
+ For the profiles downshift and upshift, this threshold reports
+ the number of times a profile must be changed within a 24 hours
+ interval to set acmsTpProfile24hAlarm.
+ "
+ ::= {acmsTpProfileRecord 5}
+
+ acmsTpProfileRowStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Status of this row of acmsTpProfileTable.
+
+ A row in the acmsTpProfileTable may not be created,
+ deleted, set to notInService or otherwise modified
+ if the there is no a row in acmsTpProfileTable with the
+ same acmsTpLinkId and the associated acmsTpLinkRowStatus
+ object is equal to active. However, if the acmsTpLinkRowStatus
+ object is equal to notInService, a row may be created, deleted
+ or modified. In other words, a profile may not be added,
+ deleted or modified if the ACM statistics of a radio link
+ is active.
+
+ The creation on a row in this table, creates a row with the same
+ index in of acmsProfileCounterTable.
+
+ If this object is set to destroy, the associated instance
+ of acmsProfileCounterTable will also be deleted by this action.
+ "
+ ::= {acmsTpProfileRecord 6}
+
+--
+-- MAINTENANCE TABLE
+--
+
+------- Begin of acmsTpMaintTable
+--
+ acmsTpMaintTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AcmsTpMaintRecord
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table with Command for maintenance of Termination Point.
+ Objects in this table is not persistent.
+ "
+ ::= {acmStats 4}
+
+ acmsTpMaintRecord OBJECT-TYPE
+ SYNTAX AcmsTpMaintRecord
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "ACM Termination Point Maintenance record.
+ An Instance of this record is created on creation of
+ acmsTpLinkTable.
+ "
+ INDEX {acmsTpLinkId, acmsTpLinkPolId}
+ ::= {acmsTpMaintTable 1}
+
+ AcmsTpMaintRecord ::=
+ SEQUENCE {
+ acmsTpMaintCounterClear INTEGER,
+ acmsTpMaintAlarmClear INTEGER
+ }
+
+ acmsTpMaintCounterClear OBJECT-TYPE
+ SYNTAX INTEGER {
+ notActive (0),
+ clear (1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object is used to clear the statistic (Perfomance Monitoring)
+ counters.
+ "
+ ::= {acmsTpMaintRecord 1}
+
+ acmsTpMaintAlarmClear OBJECT-TYPE
+ SYNTAX INTEGER {
+ notActive (0),
+ clear (1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object is used to clear the threshold cross alarms.
+ "
+ ::= {acmsTpMaintRecord 2}
+--
+------- End of acmsTpMaintTable
+
+--
+-- COUNTERS TABLE
+--
+
+------- Begin of acmsBlockTable
+--
+ acmsIntervalTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AcmsIntervalRecord
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table with records of block.
+ "
+ ::= {acmStats 5}
+
+ acmsIntervalRecord OBJECT-TYPE
+ SYNTAX AcmsIntervalRecord
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry of acmsBlockTable.
+ There is an entry in acmsBlockTable for each radio link.
+ Several (up to 19) instances of this record are created since
+ the first time that acmsTpLinkStartStop becomes start.
+ "
+ INDEX {acmsTpLinkId, acmsTpLinkPolId, acmsIntervalId}
+ ::= {acmsIntervalTable 1}
+
+ AcmsIntervalRecord ::=
+ SEQUENCE {
+ acmsIntervalId INTEGER,
+ acmsIntervalType INTEGER,
+ acmsIntervalStatus INTEGER,
+ acmsIntervalTimeStamp Unsigned32
+ }
+
+ acmsIntervalId OBJECT-TYPE
+ SYNTAX INTEGER (1..19)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object identifies time intervals according to the
+ following code:
+
+ (1) Current Daily counters
+ (2) Daily counters of the day before
+ (3) Current a day counters
+ (4) a day interval N. 1
+ (The most recently completed 15 minute interval)
+ ...
+
+ (19) a day interval N. 16
+ (The oldest day counters - 4 hours ago).
+
+ The interval identified by 4 is the most recently completed 15
+ minute interval, and the interval identified by N is the interval
+ immediately preceding the one identified by N-1.
+ "
+ ::= {acmsIntervalRecord 1}
+
+ acmsIntervalType OBJECT-TYPE
+ SYNTAX INTEGER {
+ daily (1),
+ fifteen-min (2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The type of the counter interval: it can describe a daily block
+ counter or a counter related to a 15 minutes interval.
+ "
+ ::= {acmsIntervalRecord 2}
+
+ acmsIntervalStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ meaningless (1),
+ meaningfull (2),
+ incomplete (3),
+ dummy (4),
+ lost (5),
+ restarted (6)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Interval status.
+ "
+ ::= {acmsIntervalRecord 3}
+
+ acmsIntervalTimeStamp OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The object is the time when the performance record is closed.
+ The time is shown as the number of seconds since January 1, 1970
+ "
+ ::= {acmsIntervalRecord 4}
+
+--
+------- End of acmsLinkBlockTable
+------- The following table contains the records with the counters used to monitor
+------- the ACM profile (modulation) active on the transmitted frame
+
+------- Begin of acmsProfileCounterTable
+--
+ acmsProfileCounterTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AcmsCounterRecord
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table with records of ACM statistics counters.
+ "
+ ::= {acmStats 6}
+
+ acmsProfileCounterRecord OBJECT-TYPE
+ SYNTAX AcmsCounterRecord
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry of acmsProfileCounterTable.
+ There is an entry in acmsProfileCounterTable for each profile
+ of each radio link.
+ Several (up to 19) instances of this record are created since
+ the first time that acmsTpLinkStartStop becomes start.
+ "
+ INDEX {acmsTpLinkId, acmsTpLinkPolId, acmsTpProfileId, acmsIntervalId}
+ ::= {acmsProfileCounterTable 1}
+
+ AcmsCounterRecord ::=
+ SEQUENCE {
+ acmsProfileCounterValue Counter32
+ }
+
+ acmsProfileCounterValue OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "When index acmsTpProfileId is downshift, this object counts the
+ number of times that the active profile is moved to a lower one.
+
+ When index acmsTpProfileId is upshift, this object counts the
+ number of times that the active profile is moved to an upper one.
+
+ When index acmsTpProfileId is unavailable, this object counts
+ the number of seconds in which the modem is not locked.
+
+ For all other values of acmsTpProfileId the object counts the
+ number of seconds for which the rx profile relative to this row
+ of the table has been active.
+ "
+ ::= {acmsProfileCounterRecord 1}
+
+--
+------- End of acmsProfileCounterTable
+
+--
+------- The following objects are common to all radio branches.
+--
+
+ acmsTpProfile15mAlarmSeverityCode OBJECT-TYPE
+ SYNTAX AlarmSeverityCode
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Define the severity associated to the acmsTpProfile15mAlarm
+ and enables/disables the trap generation on status change event.
+ "
+ DEFVAL {majorTrapEnable}
+ ::= {acmStats 7}
+
+ acmsTpProfile24hAlarmSeverityCode OBJECT-TYPE
+ SYNTAX AlarmSeverityCode
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Define the severity associated to the acmsTpProfile24hAlarm
+ and enables/disables the trap generation on status change event.
+ "
+ DEFVAL {majorTrapEnable}
+ ::= {acmStats 8}
+
+------ End group -----------------------------------------------------------------
+
+END
+
+
+
+