diff options
| author | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
|---|---|---|
| committer | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
| commit | 98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch) | |
| tree | 9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/siae/SIAE-ACM-STATISTICS-MIB | |
| download | mibs-main.tar.gz mibs-main.zip | |
Diffstat (limited to 'MIBS/siae/SIAE-ACM-STATISTICS-MIB')
| -rw-r--r-- | MIBS/siae/SIAE-ACM-STATISTICS-MIB | 616 |
1 files changed, 616 insertions, 0 deletions
diff --git a/MIBS/siae/SIAE-ACM-STATISTICS-MIB b/MIBS/siae/SIAE-ACM-STATISTICS-MIB new file mode 100644 index 0000000..0da4dc7 --- /dev/null +++ b/MIBS/siae/SIAE-ACM-STATISTICS-MIB @@ -0,0 +1,616 @@ +-- ---------------------------------------------------------------------------- +-- +-- SIAE MICROELETTRONICA s.p.a. +-- +-- Via Michelangelo Buonarroti, 21 +-- 20093 - Cologno Monzese +-- Milano +-- ITALY +-- +-- ---------------------------------------------------------------------------- +-- ---------------------------------------------------------------------------- + +SIAE-ACM-STATISTICS-MIB + DEFINITIONS ::= BEGIN + + IMPORTS + MODULE-IDENTITY, OBJECT-TYPE, + Counter32, Integer32, Unsigned32 + FROM SNMPv2-SMI + TEXTUAL-CONVENTION, + DisplayString, RowStatus + FROM SNMPv2-TC + siaeMib + FROM SIAE-TREE-MIB + AlarmStatus, AlarmSeverityCode + FROM SIAE-ALARM-MIB; + + acmStats MODULE-IDENTITY + LAST-UPDATED "201411050000Z" + ORGANIZATION "SIAE MICROELETTRONICA spa" + CONTACT-INFO + "SIAE MICROELETTONICA s.p.a. + Via Michelangelo Buonarroti, 21 + 20093 - Cologno Monzese + Milano - ITALY + Phone : +39-02-27325-1 + E-mail: tbd@siaemic.com + " + DESCRIPTION + "Adaptive Code Modulation (ACM) Statistics (Performance Monitoring) + " + REVISION "201411050000Z" + DESCRIPTION + "MIB version 01.00.01 + - Added ACM profilea 4096 QAM and 4096QAM strong + (changed AcmProfile TEXTUAL-CONVENTION) + " + REVISION "201402110000Z" + DESCRIPTION + "Initial version 01.00.00 + " + ::= { siaeMib 75 } + +---------------------------------------------------------------------------------- +-- Textual Conventions +---------------------------------------------------------------------------------- + + AcmProfile ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "List of supported ACM profiles. + " + SYNTAX INTEGER { + unavailable (1), -- This is a virtual profile needed to + -- create a row in the table of counters + -- in order to count seconds with modem + -- not locked. + downshift (2), -- This is a virtual profile needed to + -- create a row in the table of counters + -- in order to count transitions towards + -- lower profiles. + upshift (3), -- This is a virtual profile needed to + -- create a row in the table of counters + -- in order to count transitions towards + -- upper profiles. + acmBPSKstrong (4), + acmBPSK (5), + acm4QAMstrong (6), + acm4QAM (7), + acm8PSKstrong (8), + acm8PSK (9), + acm16QAMstrong (10), + acm16QAM (11), + acm32QAMstrong (12), + acm32QAM (13), + acm64QAMstrong (14), + acm64QAM (15), + acm128QAMstrong (16), + acm128QAM (17), + acm256QAMstrong (18), + acm256QAM (19), + acm512QAMstrong (20), + acm512QAM (21), + acm1024QAMstrong (22), + acm1024QAM (23), + acm2048QAMstrong (24), + acm2048QAM (25), + acm4096QAMstrong (26), + acm4096QAM (27) + } + +---------------------------------------------------------------------------------- +-- object identifier inside the module +---------------------------------------------------------------------------------- + +---------------------------------------------------------------------------------- +-- acmStats (PERFORMANCE MONITORING ACM) Group +---------------------------------------------------------------------------------- +-- +-- The following objects are used to manage the ACM counters. +-- The objects of this group are meaningful only if radioEquipAcmEngineEnable +-- is equal to "enable". +-- +---------------------------------------------------------------------------------- + +------ Beginning -------------------------------------------------------------- + + acmsMibVersion OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Numerical version of this module. + The string version of this MIB have the following format: + XX.YY.ZZ + so, for example, the value 1 should be interpreted as 00.00.01 + and the value 10001 should be interpreted as 01.00.01." + ::= {acmStats 1} + +-- +-- TERMINATION POINT LINK TABLE +-- + +-- +------- The following table contains the records used to manage the P.M. + +------- Begin of acmsTpLinkTable +-- + acmsTpLinkTable OBJECT-TYPE + SYNTAX SEQUENCE OF AcmsTpLinkRecord + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table with ACM Termination Point of the radio links. + This table contains object to activate and deactivate the + buildup of counters. + " + ::= {acmStats 2} + + acmsTpLinkRecord OBJECT-TYPE + SYNTAX AcmsTpLinkRecord + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry of acmsTpLinkTable. + " + INDEX {acmsTpLinkId, acmsTpLinkPolId} + ::= {acmsTpLinkTable 1} + + AcmsTpLinkRecord ::= + SEQUENCE { + acmsTpLinkId Integer32, + acmsTpLinkPolId Integer32, + acmsTpLinkStartStop INTEGER, + acmsTpLinkLabel DisplayString, + acmsTpLinkRowStatus RowStatus + } + + acmsTpLinkId OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This object identifies the Radio link. + " + ::= {acmsTpLinkRecord 1} + + acmsTpLinkPolId OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This object identifies the Radio link polarization for XPIC + configuration. In non XPIC link this object should be 1. + " + ::= {acmsTpLinkRecord 2} + + acmsTpLinkStartStop OBJECT-TYPE + SYNTAX INTEGER { + start (1), + stop (2) + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object is used to start and to stop the statistic + (Perfomance Monitoring) counter evaluation. + " + DEFVAL {stop} + ::= {acmsTpLinkRecord 3} + + acmsTpLinkLabel OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..31)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "ASCII string used to identify the ACM Termination Point. + " + ::= {acmsTpLinkRecord 4} + + acmsTpLinkRowStatus OBJECT-TYPE + SYNTAX RowStatus + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Status of this row of acmsTpLinkTable. + + When set to notInService, associated acmsTpProfileTable + rows may be added, deleted and modified. + + When an attempt is made to set acmsTpLinkRowStatus to + active, there is at least a row in acmsTpProfileTable with + first index equal to acmsTpLinkId. Otherwise, the error + inconsistentValue is returned to the set attempt. + + The creation of a row in this table, creates a row with the + same index in of acmsTpMaintTable. + + The deletion of a row in this table, deletes a row with the + same index in of acmsTpMaintTable. + + If this object is set to destroy, must not be no rows in + acmsTpProfileTable associated by acmsTpLinkId to the row + that is being deleted, otherwise, the error inconsistentValue + is returned to the set attempt. Hence, profile instances must + be deleted before this link instance. + " + ::= {acmsTpLinkRecord 5} + +-- +------- End of acmsTpLinkTable + +-- +-- PROFILE TABLE +-- + +------- Begin of acmsTpProfileTable +-- + acmsTpProfileTable OBJECT-TYPE + SYNTAX SEQUENCE OF AcmsTpProfileRecord + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "ACM Termination Point Thresholds Class table. + Table with AcmsTpProfileRecord records. + This table contains alarms and related thresholds to notify them + within a specific time interval. + " + ::= {acmStats 3} + + acmsTpProfileRecord OBJECT-TYPE + SYNTAX AcmsTpProfileRecord + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry of acmsTpLinkTable. + Several instances (a instance for each ACM profile supported by + the radio system) of this record is created on creation of + acmsTpLinkTable. + " + INDEX {acmsTpLinkId, acmsTpLinkPolId, acmsTpProfileId} + ::= {acmsTpProfileTable 1} + + AcmsTpProfileRecord ::= + SEQUENCE { + acmsTpProfileId AcmProfile, + acmsTpProfile15mAlarm AlarmStatus, + acmsTpProfile24hAlarm AlarmStatus, + acmsTpProfile15mThreshold Integer32, + acmsTpProfile24hThreshold Integer32, + acmsTpProfileRowStatus RowStatus + } + + acmsTpProfileId OBJECT-TYPE + SYNTAX AcmProfile + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This object identifies the ACM profile of the radio system. + " + ::= {acmsTpProfileRecord 1} + + acmsTpProfile15mAlarm OBJECT-TYPE + SYNTAX AlarmStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "If acmsCounteValue crosses the threshold acmsTpProfile15mThreshold, + this alarm is notified. + " + ::= {acmsTpProfileRecord 2} + + acmsTpProfile24hAlarm OBJECT-TYPE + SYNTAX AlarmStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "If acmsCounteValue crosses the threshold acmsTpProfile24hThreshold, + this alarm is notified. + " + ::= {acmsTpProfileRecord 3} + + acmsTpProfile15mThreshold OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Number of seconds within a 15 minutes interval to set + acmsTpProfile15mAlarm. The special value 0 turn off the alarm. + + For downshift and upshift profiles, this threshold reports + the number of times a profile must be changed within a 15 minutes + interval to set acmsTpProfile15mAlarm. + " + ::= {acmsTpProfileRecord 4} + + acmsTpProfile24hThreshold OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Number of seconds within a 24 hours interval to set + acmsTpProfile24hAlarm. The special value 0 turn off the alarm. + + For the profiles downshift and upshift, this threshold reports + the number of times a profile must be changed within a 24 hours + interval to set acmsTpProfile24hAlarm. + " + ::= {acmsTpProfileRecord 5} + + acmsTpProfileRowStatus OBJECT-TYPE + SYNTAX RowStatus + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Status of this row of acmsTpProfileTable. + + A row in the acmsTpProfileTable may not be created, + deleted, set to notInService or otherwise modified + if the there is no a row in acmsTpProfileTable with the + same acmsTpLinkId and the associated acmsTpLinkRowStatus + object is equal to active. However, if the acmsTpLinkRowStatus + object is equal to notInService, a row may be created, deleted + or modified. In other words, a profile may not be added, + deleted or modified if the ACM statistics of a radio link + is active. + + The creation on a row in this table, creates a row with the same + index in of acmsProfileCounterTable. + + If this object is set to destroy, the associated instance + of acmsProfileCounterTable will also be deleted by this action. + " + ::= {acmsTpProfileRecord 6} + +-- +-- MAINTENANCE TABLE +-- + +------- Begin of acmsTpMaintTable +-- + acmsTpMaintTable OBJECT-TYPE + SYNTAX SEQUENCE OF AcmsTpMaintRecord + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table with Command for maintenance of Termination Point. + Objects in this table is not persistent. + " + ::= {acmStats 4} + + acmsTpMaintRecord OBJECT-TYPE + SYNTAX AcmsTpMaintRecord + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "ACM Termination Point Maintenance record. + An Instance of this record is created on creation of + acmsTpLinkTable. + " + INDEX {acmsTpLinkId, acmsTpLinkPolId} + ::= {acmsTpMaintTable 1} + + AcmsTpMaintRecord ::= + SEQUENCE { + acmsTpMaintCounterClear INTEGER, + acmsTpMaintAlarmClear INTEGER + } + + acmsTpMaintCounterClear OBJECT-TYPE + SYNTAX INTEGER { + notActive (0), + clear (1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object is used to clear the statistic (Perfomance Monitoring) + counters. + " + ::= {acmsTpMaintRecord 1} + + acmsTpMaintAlarmClear OBJECT-TYPE + SYNTAX INTEGER { + notActive (0), + clear (1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object is used to clear the threshold cross alarms. + " + ::= {acmsTpMaintRecord 2} +-- +------- End of acmsTpMaintTable + +-- +-- COUNTERS TABLE +-- + +------- Begin of acmsBlockTable +-- + acmsIntervalTable OBJECT-TYPE + SYNTAX SEQUENCE OF AcmsIntervalRecord + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table with records of block. + " + ::= {acmStats 5} + + acmsIntervalRecord OBJECT-TYPE + SYNTAX AcmsIntervalRecord + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry of acmsBlockTable. + There is an entry in acmsBlockTable for each radio link. + Several (up to 19) instances of this record are created since + the first time that acmsTpLinkStartStop becomes start. + " + INDEX {acmsTpLinkId, acmsTpLinkPolId, acmsIntervalId} + ::= {acmsIntervalTable 1} + + AcmsIntervalRecord ::= + SEQUENCE { + acmsIntervalId INTEGER, + acmsIntervalType INTEGER, + acmsIntervalStatus INTEGER, + acmsIntervalTimeStamp Unsigned32 + } + + acmsIntervalId OBJECT-TYPE + SYNTAX INTEGER (1..19) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object identifies time intervals according to the + following code: + + (1) Current Daily counters + (2) Daily counters of the day before + (3) Current a day counters + (4) a day interval N. 1 + (The most recently completed 15 minute interval) + ... + + (19) a day interval N. 16 + (The oldest day counters - 4 hours ago). + + The interval identified by 4 is the most recently completed 15 + minute interval, and the interval identified by N is the interval + immediately preceding the one identified by N-1. + " + ::= {acmsIntervalRecord 1} + + acmsIntervalType OBJECT-TYPE + SYNTAX INTEGER { + daily (1), + fifteen-min (2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The type of the counter interval: it can describe a daily block + counter or a counter related to a 15 minutes interval. + " + ::= {acmsIntervalRecord 2} + + acmsIntervalStatus OBJECT-TYPE + SYNTAX INTEGER { + meaningless (1), + meaningfull (2), + incomplete (3), + dummy (4), + lost (5), + restarted (6) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Interval status. + " + ::= {acmsIntervalRecord 3} + + acmsIntervalTimeStamp OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The object is the time when the performance record is closed. + The time is shown as the number of seconds since January 1, 1970 + " + ::= {acmsIntervalRecord 4} + +-- +------- End of acmsLinkBlockTable +------- The following table contains the records with the counters used to monitor +------- the ACM profile (modulation) active on the transmitted frame + +------- Begin of acmsProfileCounterTable +-- + acmsProfileCounterTable OBJECT-TYPE + SYNTAX SEQUENCE OF AcmsCounterRecord + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table with records of ACM statistics counters. + " + ::= {acmStats 6} + + acmsProfileCounterRecord OBJECT-TYPE + SYNTAX AcmsCounterRecord + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry of acmsProfileCounterTable. + There is an entry in acmsProfileCounterTable for each profile + of each radio link. + Several (up to 19) instances of this record are created since + the first time that acmsTpLinkStartStop becomes start. + " + INDEX {acmsTpLinkId, acmsTpLinkPolId, acmsTpProfileId, acmsIntervalId} + ::= {acmsProfileCounterTable 1} + + AcmsCounterRecord ::= + SEQUENCE { + acmsProfileCounterValue Counter32 + } + + acmsProfileCounterValue OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "When index acmsTpProfileId is downshift, this object counts the + number of times that the active profile is moved to a lower one. + + When index acmsTpProfileId is upshift, this object counts the + number of times that the active profile is moved to an upper one. + + When index acmsTpProfileId is unavailable, this object counts + the number of seconds in which the modem is not locked. + + For all other values of acmsTpProfileId the object counts the + number of seconds for which the rx profile relative to this row + of the table has been active. + " + ::= {acmsProfileCounterRecord 1} + +-- +------- End of acmsProfileCounterTable + +-- +------- The following objects are common to all radio branches. +-- + + acmsTpProfile15mAlarmSeverityCode OBJECT-TYPE + SYNTAX AlarmSeverityCode + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Define the severity associated to the acmsTpProfile15mAlarm + and enables/disables the trap generation on status change event. + " + DEFVAL {majorTrapEnable} + ::= {acmStats 7} + + acmsTpProfile24hAlarmSeverityCode OBJECT-TYPE + SYNTAX AlarmSeverityCode + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Define the severity associated to the acmsTpProfile24hAlarm + and enables/disables the trap generation on status change event. + " + DEFVAL {majorTrapEnable} + ::= {acmStats 8} + +------ End group ----------------------------------------------------------------- + +END + + + + |