summaryrefslogtreecommitdiff
path: root/MIBS/siae/SIAE-RADIO-SYSTEM-MIB
diff options
context:
space:
mode:
authorDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
committerDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
commit98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch)
tree9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/siae/SIAE-RADIO-SYSTEM-MIB
downloadmibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.tar.gz
mibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.zip
Initial commitHEADmain
Diffstat (limited to 'MIBS/siae/SIAE-RADIO-SYSTEM-MIB')
-rw-r--r--MIBS/siae/SIAE-RADIO-SYSTEM-MIB4692
1 files changed, 4692 insertions, 0 deletions
diff --git a/MIBS/siae/SIAE-RADIO-SYSTEM-MIB b/MIBS/siae/SIAE-RADIO-SYSTEM-MIB
new file mode 100644
index 0000000..543785e
--- /dev/null
+++ b/MIBS/siae/SIAE-RADIO-SYSTEM-MIB
@@ -0,0 +1,4692 @@
+-- ----------------------------------------------------------------------------
+--
+-- SIAE MICROELETTRONICA s.p.a.
+--
+-- Via Michelangelo Buonarroti, 21
+-- 20093 - Cologno Monzese
+-- Milano
+-- ITALY
+--
+-- ----------------------------------------------------------------------------
+-- ----------------------------------------------------------------------------
+
+SIAE-RADIO-SYSTEM-MIB
+ DEFINITIONS ::= BEGIN
+
+ IMPORTS
+ MODULE-IDENTITY, OBJECT-TYPE,
+ NOTIFICATION-TYPE,
+ Integer32, Counter32
+ FROM SNMPv2-SMI
+ InterfaceIndexOrZero
+ FROM IF-MIB
+ TEXTUAL-CONVENTION,
+ DisplayString, RowStatus, StorageType
+ FROM SNMPv2-TC
+ siaeMib
+ FROM SIAE-TREE-MIB
+ AlarmStatus, AlarmSeverityCode, alarmTrap
+ FROM SIAE-ALARM-MIB
+ equipIpSnmpAgentAddress
+ FROM SIAE-EQUIP-MIB;
+
+ radioSystem MODULE-IDENTITY
+ LAST-UPDATED "201607140000Z"
+ ORGANIZATION "SIAE MICROELETTRONICA spa"
+ CONTACT-INFO
+ "SIAE MICROELETTONICA s.p.a.
+ Via Michelangelo Buonarroti, 21
+ 20093 - Cologno Monzese
+ Milano - ITALY
+ Phone : +39-02-27325-1
+ E-mail: help@siaemic.com
+ "
+ DESCRIPTION
+ "Radio System MIB.
+ "
+ REVISION "201607140000Z"
+ DESCRIPTION
+ "MIB version 01.00.05
+ - added radioXpd in radioStatusTable
+ - deprecated linkXpd in linkStatusTable
+ "
+ REVISION "201602290000Z"
+ DESCRIPTION
+ "MIB version 01.00.04
+ - Added linkXpd to linkStatusTable
+ - changed MAX-ACCESS clause of linkChRadioSettingsIdx from
+ read-only to read-create
+ - Fixed DESCRIPTION of linkSettingsTable
+ "
+ REVISION "201509150000Z"
+ DESCRIPTION
+ "Fixed DESCRIPTION of radioTxChannelSpacing
+ "
+ REVISION "201506180000Z"
+ DESCRIPTION
+ "MIB version 01.00.03
+ - Added linkConfigurationInProgress and
+ linkConfigurationInProgressTrapNotification
+ - Added radio radioRxBerThresholdTable
+ - Added fadeMarginMeasure
+ - Deprecated linkFadeMarginMeasure
+ - Added table radioLoopCapabilityTable
+ - Added table sspTable
+ - Added table stm1BulkSettingsTable
+ - Added table linkE1vsSTM1CapacityTable
+ - Deprecated linkAcmMaxTDMCapacity
+ - Deprecated linkTfcTable, linkProTable and linkProMaintTable.
+ - Added linkTfcV2Table, linkProV2Table and linkProMaintV2Table
+ in order to replace deprecated tables.
+ - Added channelSpacingSelection
+ "
+ REVISION "201503230000Z"
+ DESCRIPTION
+ "Removed alarmTrapNumber from TRAPs and IMPORTS.
+ "
+ REVISION "201411050000Z"
+ DESCRIPTION
+ "MIB version 01.00.02
+ Changes for support of modulation 4096QAM:
+ - DESCRIPTION of linkBandwidthAndModulation
+ - ModulationMap TEXTUAL-CONVENTION
+ - BitsPerSymbol TEXTUAL-CONVENTION
+ Changes for support of channel spacing 60MHz and 80MHz:
+ - DESCRIPTION of linkBandwidthAndModulation
+ - ChannelSpacing TEXTUAL-CONVENTION
+ "
+ REVISION "201409160000Z"
+ DESCRIPTION
+ "MIB version 01.00.01
+ - Added combinedRadioCapabilitiesTable, combinedRadioFrequencyTable,
+ combinedRadioDuplexFrequencyTable and combinedRadioPowerScalingTable
+ - Declared deprecated linkCapabilitiesTable, linkFrequencyTable,
+ linkDuplexFrequencyTable, linkAcmPowerScaling,
+ linkAcmAtpcRxPowerScaling and linkAcmPowerRange.
+ - Added linkNotMatchingRadiosAlarm and
+ linkNotMatchingRadiosAlarmSeverityCode
+ "
+ REVISION "201404010000Z"
+ DESCRIPTION
+ "Initial version 01.00.00.
+ "
+ ::= { siaeMib 80 }
+
+----------------------------------------------------------------------------------
+-- Textual Conventions
+----------------------------------------------------------------------------------
+
+ ChannelSpacing ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "This TC describes a data type which identifies a RF channel spacing.
+ "
+ SYNTAX INTEGER {
+ -- ETSI
+ bw3M5Hz (0),
+ bw7Mhz (1),
+ bw14MHz (2),
+ bw28MHz (3),
+ bw40MHz (5),
+ bw56MHz (4),
+ bw112MHz (6),
+ bw250Mhz (7),
+ bw500Mhz (8),
+ bw750Mhz (9),
+ bw1000Mhz (10),
+ -- FCC
+ bw10Mhz (11),
+ bw20Mhz (12),
+ bw30Mhz (13),
+ bw50Mhz (14),
+ bw60Mhz (15),
+ bw80Mhz (16)
+ }
+
+
+ ModulationMap ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "This data type is used as the syntax of the radioBranchModulationMap
+ and radioBranchRefModulationMap objects.
+ "
+ SYNTAX BITS {
+ modBPSK (0),
+ mod4QAM (1),
+ mod8PSK (2),
+ mod16QAM (3),
+ mod32QAM (4),
+ mod64QAM (5),
+ mod128QAM (6),
+ mod256QAM (7),
+ mod512QAM (8),
+ mod1024QAM (9),
+ mod2048QAM (10),
+ mod4096QAM (11)
+ }
+
+
+ ConfigMismatchReason ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "This data type is used to specify the cause of Config Mismatch Alarm,
+ that is the mismatch between the radio link capability and the current
+ local and remote configuration.
+ - securityMismatch(0)
+ Copyright violation
+ - frequencyFailMismatch(1)
+ Configured frequency is out of Filter-Bandwidth
+ - frequencyAlertMismatch(2)
+ Configured frequency across Filter-Bandwidth
+ - ptxMismatch(3)
+ Tx power configured incongruent with RF Tx power limits
+ - channelSpacingAndModulationMismatch(4)
+ Bandwidth and/or modulation configured is invalid
+ (RF doesn't support it)
+ - remoteConfigurationMismatch(5)
+ Incongruence between the couple of Terminal Radio Unit (TRU)
+ in the link:
+ - Frequency Incongruent (Freq)
+ - Reference Bandwidth and Modulation incongruent
+ - Acm-Tx map in congruent with remote Acm-Rx map
+ - acmMismatch(6)
+ Obsolete (no longer used)
+ - profileSetMismatch(7)
+ The selected profile set is not supported by the TRU
+ "
+ SYNTAX BITS {
+ securityMismatch(0),
+ frequencyFailMismatch(1),
+ frequencyAlertMismatch(2),
+ ptxMismatch(3),
+ channelSpacingAndModulationMismatch(4),
+ remoteConfigurationMismatch(5),
+ acmMismatch(6),
+ profileSetMismatch(7)
+ }
+
+ RadioCapability ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "This data type is used as the syntax of the radioBranchKeyFeatures
+ objects.
+ "
+ SYNTAX BITS {
+ reserved (0),
+ trafficSquelch (1),
+ baseBandLoop (2),
+ maxPower (3),
+ carrierOnly (4),
+ iQLoop (5),
+ rfLoopGivenMod (6), -- only at a given modulation
+ rfLoopAnyMod (7) -- at any modulation
+ }
+
+ BitsPerSymbol ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "his TC describes a data type which identifies a RF channel spacing.
+ "
+ SYNTAX INTEGER {
+ bpsBPSK (1),
+ bps4QAM (2),
+ bps8PSK (3),
+ bps16QAM (4),
+ bps32QAM (5),
+ bps64QAM (6),
+ bps128QAM (7),
+ bps256QAM (8),
+ bps512QAM (9),
+ bps1024QAM (10),
+ bps2048QAM (11),
+ bps4096QAM (12)
+ }
+
+ Stm1IndexOrZero ::= TEXTUAL-CONVENTION
+ DISPLAY-HINT "d"
+ STATUS current
+ DESCRIPTION
+ "This textual convention permits the
+ additional value of zero to an stm1Index in stm1Table.
+ The value zero is object-specific and must therefore be
+ defined as part of the description of any object which
+ uses this syntax. Examples of the usage of zero might
+ include situations where stm-1 was unknown, or when none
+ or all stm-1s need to be referenced."
+ SYNTAX Integer32 (0..2147483647)
+
+----------------------------------------------------------------------------------
+-- radioSystem GROUP
+----------------------------------------------------------------------------------
+--
+-- This group contains all the objects that are specific of the radio system
+--
+----------------------------------------------------------------------------------
+
+------ Beginning --------------------------------------------------------------
+
+ radioSystemMibVersion OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Numerical version of this module.
+ The string version of this MIB have the following format:
+ XX.YY.ZZ
+ so, for example, the value 1 should be interpreted as 00.00.01
+ and the value 10001 should be interpreted as 01.00.01."
+ ::= {radioSystem 1}
+
+------- Begin of radioTable
+--
+ radioTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF RadioEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of radio interface entries. This table is useful
+ to show the manager all the available radio interfaces
+ on the equipment. Moreover it is a reference for
+ Performance Monitoring (PWR and G828).
+ "
+ ::= {radioSystem 2}
+
+ radioEntry OBJECT-TYPE
+ SYNTAX RadioEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing management information applicable to a
+ particular radio interface.
+ "
+ INDEX {radioIndex}
+ ::= {radioTable 1}
+
+ RadioEntry ::=
+ SEQUENCE {
+ radioIndex Integer32,
+ radioLabel DisplayString,
+ radioType INTEGER,
+ radioIfIndex InterfaceIndexOrZero,
+ radioStorageType StorageType
+ }
+
+ radioIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A unique value, greater than zero, for each radio
+ interface. It is recommended that values are assigned
+ contiguously starting from 1.
+ "
+ ::= {radioEntry 1}
+
+ radioLabel OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..32))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A textual string containing information about the radio
+ interface. This string should include the name of the
+ manufacturer, the product name and the version of the
+ interface hardware/software.
+ "
+ ::= {radioEntry 2}
+
+ radioType OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1),
+ analogRadio(2), -- analogic radio --
+ digitalRadio(3), -- digital radio --
+ xpicRadio(4) -- xpic radio --
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The type of interface.
+ "
+ ::= {radioEntry 3}
+
+ radioIfIndex OBJECT-TYPE
+ SYNTAX InterfaceIndexOrZero
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object defines a greater than zero value
+ to identify an interface in ifTable or a zero
+ value if ifTable is not supported.
+ "
+ ::= {radioEntry 4}
+
+ radioStorageType OBJECT-TYPE
+ SYNTAX StorageType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The storage type of this conceptual row. Conceptual
+ rows having the value 'permanent' need not allow
+ write-access to any columnar objects in the row.
+ "
+ ::= {radioEntry 5}
+
+--
+------- End of radioTable
+
+------- Begin of xpicTable
+--
+ xpicTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF XpicEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of xpic radio interface entries. If a manager
+ wants to make an xpic link, it should only add a
+ particular xpic radio interface to an xpic link.
+ "
+ ::= {radioSystem 3}
+
+ xpicEntry OBJECT-TYPE
+ SYNTAX XpicEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing management information applicable to a
+ particular xpic radio interface.
+ "
+ INDEX {xpicIndex}
+ ::= {xpicTable 1}
+
+ XpicEntry ::=
+ SEQUENCE {
+ xpicIndex Integer32,
+ xpicRadioIdx Integer32,
+ xpicRowstatus RowStatus
+ }
+
+ xpicIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A unique value, greater than zero, for each xpic radio
+ interface. It is recommended that values are assigned
+ contiguously starting from 1.
+ "
+ ::= {xpicEntry 1}
+
+ xpicRadioIdx OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Index of xpic radio interface, corresponding
+ to an available xpic radio interface in radioTable.
+ "
+ ::= {xpicEntry 2}
+
+ xpicRowstatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Status of this conceptual row in xpicTable.
+ "
+ ::= {xpicEntry 3}
+
+--
+------- End of xpicTable
+
+------- Begin of xpicChTable
+--
+ xpicChTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF XpicChEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of xpic channel entries. This table maps
+ each xpic radio in respective xpic radio interface.
+ "
+ ::= {radioSystem 4}
+
+ xpicChEntry OBJECT-TYPE
+ SYNTAX XpicChEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing management information applicable to a
+ particular xpic channel. It defines radio interface and
+ polarization for a given xpic channel.
+ "
+ INDEX {xpicIndex,
+ xpicChPolIndex}
+ ::= {xpicChTable 1}
+
+ XpicChEntry ::=
+ SEQUENCE {
+ xpicChPolIndex Integer32,
+ xpicChRadioIdx Integer32,
+ xpicChRowstatus RowStatus
+ }
+
+ xpicChPolIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..2)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object identifies the xpic radio polarization.
+ "
+ ::= {xpicChEntry 1}
+
+ xpicChRadioIdx OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Xpic radio interface, corresponding to a radio interface
+ in radioTable, used to make up the given xpic radio interface.
+ "
+ ::= {xpicChEntry 2}
+
+ xpicChRowstatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Status of this conceptual row in xpicChTable.
+ "
+ ::= {xpicChEntry 3}
+
+--
+------- End of xpicChTable
+
+ linkAvailableIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Shows an index which is available for creation of a new link
+ in the system. It shows the smallest available index.
+ Any attempt to create a link with a different index results
+ in a failure.
+ "
+ ::= {radioSystem 5}
+
+------- Begin of linkTable
+--
+ linkTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF LinkEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of link entries.
+ "
+ ::= {radioSystem 6}
+
+ linkEntry OBJECT-TYPE
+ SYNTAX LinkEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing management information applicable to a
+ particular link.
+ "
+ INDEX {linkIndex}
+ ::= {linkTable 1}
+
+ LinkEntry ::=
+ SEQUENCE {
+ linkIndex Integer32,
+ linkType INTEGER,
+ linkLabel DisplayString,
+ linkIfIndex InterfaceIndexOrZero,
+ linkRowstatus RowStatus
+ }
+
+ linkIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A unique value, greater than zero, for each link.
+ Manager must use the first available index,
+ suggested by linkAvailableIndex.
+ "
+ ::= {linkEntry 1}
+
+ linkType OBJECT-TYPE
+ SYNTAX INTEGER {
+ radio1p0(1), -- 1+0
+ radio1p1HS(2), -- 1+1 Hot Standby
+ radio1p1FD(3), -- 1+1 Frequency Diversity
+ radio2p0Xpic(4), -- 2+0 XPIC
+ radio2p2XpicHS(5), -- 2+2 XPIC Hot Standby
+ radio2p2XpicFD(6), -- 2+2 XPIC Frequency Diversity
+ radioNp1(7) -- N+1
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object identifies link type. Supported link types are:
+ single link, 1+1 Hot Standby, 1+1 Frequency Diversity, 2+0 XPIC,
+ 2+2 XPIC Hot Standby, 2+2 XPIC Frequency Diversity and N+1.
+ "
+ DEFVAL {radio1p0}
+ ::= {linkEntry 2}
+
+ linkLabel OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..32))
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "A textual string containing information about the link.
+ This string should give more details about link specific
+ parameters.
+ "
+ DEFVAL {""}
+ ::= {linkEntry 3}
+
+ linkIfIndex OBJECT-TYPE
+ SYNTAX InterfaceIndexOrZero
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object defines a greater than zero value
+ to identify a link in ifTable or a zero
+ value if ifTable is not supported.
+ "
+ DEFVAL {0}
+ ::= {linkEntry 4}
+
+ linkRowstatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Status of this row of linkTable. This object is used to manage the
+ creation and deletion of conceptual rows in linkTable.
+ To create a row in this table, a manager should set rowstatus to
+ createAndWait(5) and choose a link type. Respective entries in
+ linkSettingsTable, linkStatusTable and tdmSettingsTable will be
+ created by agent.In case of protection links proper entries in
+ linkProtectionTable will be also created.
+ Until instances of all corresponding columns are appropriately
+ configured, the value of the corresponding instance of rowstatus
+ is notReady(3).
+ When there is sufficient information to (attempt to) make the
+ conceptual row available for use by the managed device,
+ then the rowstatus column turns into notInService(2); manager
+ must set rowstatus to active(1) to make the conceptual row
+ active.
+ The contents of linkSettingsTable and radioSettingsTable can be
+ changed only if this object is notInService(2).
+ "
+ ::= {linkEntry 5}
+
+--
+------- End of linkTable
+
+------- Begin of linkChTable
+--
+ linkChTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF LinkChEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of link channel entries.
+ "
+ ::= {radioSystem 7}
+
+ linkChEntry OBJECT-TYPE
+ SYNTAX LinkChEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing management information applicable to a
+ particular link channel.
+ "
+ INDEX {linkIndex,
+ linkChIndex}
+ ::= {linkChTable 1}
+
+ LinkChEntry ::=
+ SEQUENCE {
+ linkChIndex Integer32,
+ linkChRadioIdx Integer32,
+ linkChRadioSettingsIdx Integer32,
+ linkChRowstatus RowStatus
+ }
+
+ linkChIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Link Channel Index.
+ "
+ ::= {linkChEntry 1}
+
+ linkChRadioIdx OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Radio channel index that corresponds to an
+ available radio interface in radioTable.
+ "
+ ::= {linkChEntry 2}
+
+ linkChRadioSettingsIdx OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Radio Settings Index. This object is a foreign
+ key for a corresponding radioSettingsTable entry,
+ which is automatically created by agent.
+ "
+ DEFVAL {0}
+ ::= {linkChEntry 3}
+
+ linkChRowstatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Status of this row of linkChTable. This object is used
+ to manage the creation and deletion of conceptual rows in
+ linkChTable.
+ To create a row in this table, a manager should set rowstatus to
+ createAndWait(5). Until instances of all corresponding columns
+ are appropriately configured, the value of the corresponding
+ instance of rowstatus is notReady(3).
+ When there is sufficient information to (attempt to) make the
+ conceptual row available for use by the managed device,
+ then the rowstatus column turns into notInService(2); manager
+ must set rowstatus to active(1) to make the conceptual row
+ active.
+ The content of radioSettingsTable can be changed only if this
+ object is notInService(2).
+ "
+ ::= {linkChEntry 4}
+--
+------- End of linkChTable
+
+------- Begin of linkSettingsTable
+--
+ linkSettingsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF LinkSettingsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table with link settings entries. This table contains all
+ parameters of a radio frequency link. The content of this
+ table can be changed by a manager if linkRowStatus is
+ notInService(2)."
+ ::= {radioSystem 8}
+
+ linkSettingsEntry OBJECT-TYPE
+ SYNTAX LinkSettingsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Radio link entry"
+ INDEX {linkIndex}
+ ::= {linkSettingsTable 1}
+
+ LinkSettingsEntry ::=
+ SEQUENCE {
+ linkBandwidthAndModulation Integer32,
+ linkAcmEngineEnable INTEGER,
+ linkTxUpperProfile INTEGER,
+ linkTxLowerProfile INTEGER,
+ linkId INTEGER,
+ linkTxPwrThresh INTEGER,
+ linkRxPwrThresh INTEGER,
+ linkSynchSetupProtocolEnable INTEGER,
+ linkProfilesSetSelection INTEGER,
+ linkXpicControlProcedure INTEGER
+ }
+
+ linkBandwidthAndModulation OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Link Modulation and Bandwidth (channel spacing).
+ The value of this object value is computed by:
+ 65536*modulation+bandwidth
+ where bandwidth selection is:
+ 0 = 3.5Mhz
+ 1 = 7MHz
+ 2 = 14MHz
+ 3 = 28MHz
+ 4 = 56MHz
+ 5 = 10MHz
+ 6 = 20MHz
+ 7 = 30MHz
+ 8 = 40MHz
+ 9 = 50MHz
+ 10 = 112Mhz
+ 11 = 250Mhz
+ 12 = 500Mhz
+ 13 = 750Mhz
+ 14 = 1Ghz
+ 15 = 60MHz
+ 16 = 80MHz
+ and modulation is in bit-per-symbol:
+ 1 = BPSK
+ 2 = 4QAM
+ 3 = 8PSK
+ 4 = 16QAM
+ 5 = 32QAM
+ 6 = 64QAM
+ 7 = 128QAM
+ 8 = 256QAM
+ 9 = 512QAM
+ 10 = 1024QAM
+ 11 = 2048QAM.
+ 12 = 4096QAM.
+
+ Examples:
+ 250Mhz-4QAM (131083),
+ 500Mhz-4QAM (131084),
+ 250Mhz-16QAM (262155),
+ 500Mhz-64QAM (393228).
+
+ Note: 0 bit-per-symbol is not possible,
+ so value 0 is used for
+ BandwidthAndModulation unassigned."
+ ::= {linkSettingsEntry 1}
+
+ linkAcmEngineEnable OBJECT-TYPE
+ SYNTAX INTEGER {
+ disable (1),
+ enable (2)
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object is used to enable/disable the ACM engine"
+ DEFVAL { disable }
+ ::= {linkSettingsEntry 2}
+
+ linkTxUpperProfile OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The object (and linkTxLowerProfile object) is used to
+ restrict the TX profile range when ACM is enabled."
+ ::= {linkSettingsEntry 3}
+
+ linkTxLowerProfile OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The object (and linkTxUpperProfile object) is used to
+ restrict the TX profile range when ACM is enabled."
+ ::= {linkSettingsEntry 4}
+
+ linkId OBJECT-TYPE
+ SYNTAX INTEGER (0..255)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Link Identification (value 0..255)"
+ DEFVAL {0}
+ ::= {linkSettingsEntry 5}
+
+ linkTxPwrThresh OBJECT-TYPE
+ SYNTAX INTEGER (3..15)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Threshold (value +3 , +15 dB) relative to nominal value of the TX power
+ below wich the related alarm is set."
+ DEFVAL {3}
+ ::= {linkSettingsEntry 6}
+
+ linkRxPwrThresh OBJECT-TYPE
+ SYNTAX INTEGER (-99..-40)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Threshold (value -40 , -99 dBm) for RX power below wich the related
+ alarm is set."
+ DEFVAL {-70}
+ ::= {linkSettingsEntry 7}
+
+ linkSynchSetupProtocolEnable OBJECT-TYPE
+ SYNTAX INTEGER {
+ disable (1),
+ enable (2)
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Synchronization Setup Protocol (SSP) control"
+ DEFVAL {disable}
+ ::= {linkSettingsEntry 8}
+
+ linkProfilesSetSelection OBJECT-TYPE
+ SYNTAX INTEGER {
+ highThroughput (1),
+ highGain (2)
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Selection of the working profile set between high gain
+ (max robustness) profile set and high throughput (max
+ capacity) profile set. The set of profiles high gain
+ features a greater robustness against to the set of
+ profiles high throughput.
+ For radio systems that do not have more sets of profiles,
+ this object becomes read only and its reading shows the
+ only one set of profiles supported.
+ "
+ DEFVAL {highThroughput}
+ ::= {linkSettingsEntry 9}
+
+ linkXpicControlProcedure OBJECT-TYPE
+ SYNTAX INTEGER {
+ disable (1),
+ enable (2)
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Set by manager to enable\disable XPIC alarm control procedure.
+ Only for XPIC configurations."
+ DEFVAL { enable }
+ ::= {linkSettingsEntry 10}
+
+--
+------- End of linkSettingsTable
+
+------- Begin of radioSettingsTable
+--
+ radioSettingsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF RadioSettingsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table with radio settings entries. This table contains all
+ parameters of a radio terminal. The content of this table
+ can be changed only linkRowStatus is notInService(2)"
+ ::= {radioSystem 9}
+
+ radioSettingsEntry OBJECT-TYPE
+ SYNTAX RadioSettingsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Radio terminal entry"
+ INDEX {radioSettingsIndex}
+ ::= {radioSettingsTable 1}
+
+ RadioSettingsEntry ::=
+ SEQUENCE {
+ radioSettingsIndex Integer32,
+ radioSettingsRowStatus RowStatus,
+ radioSettingsLabel DisplayString,
+ radioTxFrequency INTEGER,
+ radioDuplexFrequency INTEGER,
+ radioTxAttenuation INTEGER,
+ radioAtpcManual INTEGER,
+ radioAtpcPwrHigh Integer32,
+ radioAtpcPwrLow Integer32,
+ radioAtpcRange Integer32,
+ radioFreqTableSelection ChannelSpacing
+ }
+
+ radioSettingsIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Radio settings index.
+ "
+ ::= {radioSettingsEntry 1}
+
+ radioSettingsRowStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Status of this row.
+ "
+ ::= {radioSettingsEntry 2}
+
+ radioSettingsLabel OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..32))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A textual string containing information about the radio
+ interface.
+ "
+ ::= {radioSettingsEntry 3}
+
+ radioTxFrequency OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Transmitted frequency in KHz. Null value means invalid frequency."
+ DEFVAL {0}
+ ::= {radioSettingsEntry 4}
+
+ radioDuplexFrequency OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Value of duplex frequency in KHz. -2 means not set."
+ DEFVAL {-2}
+ ::= {radioSettingsEntry 5}
+
+ radioTxAttenuation OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Transmitter attenuation relative to nominal power (dBm)."
+ ::= {radioSettingsEntry 6}
+
+ radioAtpcManual OBJECT-TYPE
+ SYNTAX INTEGER {
+ disable (1),
+ enable (2)
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Enables/disables Atpc Manual operation."
+ DEFVAL {disable}
+ ::= {radioSettingsEntry 7}
+
+ radioAtpcPwrHigh OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "ATPC Control - Local Rx Power High (dBm range -30 to -80) -."
+ DEFVAL {-40}
+ ::= {radioSettingsEntry 8}
+
+ radioAtpcPwrLow OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "ATPC Control - Local Rx Power Low (dBm range -30 to -80) -."
+ DEFVAL {-60}
+ ::= {radioSettingsEntry 9}
+
+ radioAtpcRange OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Defines the range of the ATPC regulation (expressed in dB) with respect
+ to the current value of maximum Tx output, that is intended as the upper
+ limit of the range. A null value means no limit: the lower limit
+ of the range is equal to minimum Ptx."
+ DEFVAL {0}
+ ::= {radioSettingsEntry 10}
+
+ radioFreqTableSelection OBJECT-TYPE
+ SYNTAX ChannelSpacing
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "RadioFrequencyTable key (channel spacing & modulation) selection."
+ ::= {radioSettingsEntry 11}
+
+--
+------- End of radioSettingsTable
+
+------- Begin of tdmSettingsTable
+--
+ tdmSettingsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TdmSettingsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table with tdm settings entries.
+ "
+ ::= {radioSystem 10}
+
+ tdmSettingsEntry OBJECT-TYPE
+ SYNTAX TdmSettingsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing tdm parameters for a particular link.
+ "
+ INDEX {linkIndex,
+ tdmPolIndex}
+ ::= {tdmSettingsTable 1}
+
+ TdmSettingsEntry ::=
+ SEQUENCE {
+ tdmPolIndex Integer32,
+ tdmE1Channel Integer32,
+ tdmE1Framer INTEGER
+ }
+
+ tdmPolIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Polarization index.
+ "
+ ::= {tdmSettingsEntry 1}
+
+ tdmE1Channel OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number of E1 channels. This object is used to define the capacity
+ of E1 tributaries assigned to a given radio link. The capacity is
+ changed in steps of E1 (2Mbit/s).
+ "
+ DEFVAL {0}
+ ::= {tdmSettingsEntry 2}
+
+ tdmE1Framer OBJECT-TYPE
+ SYNTAX INTEGER {
+ disable (1),
+ enable (2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object is used to attach the framer to a given E1.
+ "
+ DEFVAL {disable}
+ ::= {tdmSettingsEntry 3}
+
+--
+------- End of tdmSettingsTable
+
+------- Begin of radioCapabilitiesTable
+--
+ radioCapabilitiesTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF RadioCapabilitiesEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table with RadioCapabilities entries: there is an entry for each
+ radioTable rows."
+ ::= {radioSystem 11}
+
+ radioCapabilitiesEntry OBJECT-TYPE
+ SYNTAX RadioCapabilitiesEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "RadioCapabilities entry."
+ INDEX {radioIndex}
+ ::= {radioCapabilitiesTable 1}
+
+ RadioCapabilitiesEntry ::=
+ SEQUENCE {
+ radioCapabilitiesCapability RadioCapability,
+ radioCapabilitiesTxMinFrequency Integer32,
+ radioCapabilitiesTxMaxFrequency Integer32,
+ radioCapabilitiesStepFrequency Integer32,
+ radioCapabilitiesMinPtxNominalValue Integer32,
+ radioCapabilitiesMaxPtxNominalValue Integer32,
+ radioCapabilitiesExtendedMinPwr Integer32
+ }
+
+ radioCapabilitiesCapability OBJECT-TYPE
+ SYNTAX RadioCapability
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Bit map to describe the radio features."
+ ::= {radioCapabilitiesEntry 1}
+
+ radioCapabilitiesTxMinFrequency OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Minimum of available channel frequency in KHz."
+ ::= {radioCapabilitiesEntry 2}
+
+ radioCapabilitiesTxMaxFrequency OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Maximum of available channel frequency in KHz."
+ ::= {radioCapabilitiesEntry 3}
+
+ radioCapabilitiesStepFrequency OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Minimum frequency step in KHz."
+ ::= {radioCapabilitiesEntry 4}
+
+ radioCapabilitiesMinPtxNominalValue OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Minimum nominal Ptx in dBm."
+ ::= {radioCapabilitiesEntry 5}
+
+ radioCapabilitiesMaxPtxNominalValue OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Maximum nominal Ptx in dBm."
+ ::= {radioCapabilitiesEntry 6}
+
+ radioCapabilitiesExtendedMinPwr OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Minimum extended Ptx power for fade margin."
+ ::= {radioCapabilitiesEntry 7}
+--
+------- End of radioCapabilitiesTable
+
+------- Begin of radioStatusTable
+--
+ radioStatusTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF RadioStatusEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table with RadioStatus records: one record for 1+0 configuration and
+ two record for 1+1 configuration."
+ ::= {radioSystem 12}
+
+ radioStatusEntry OBJECT-TYPE
+ SYNTAX RadioStatusEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "RadioStatus record."
+ INDEX {radioIndex}
+ ::= {radioStatusTable 1}
+
+ RadioStatusEntry ::=
+ SEQUENCE {
+ radioCurrentDuplexFrequency Integer32,
+ radioTxChannelSpacing Integer32,
+ radioPrx Integer32,
+ radioPtx Integer32,
+ radioNormalizedMse Integer32,
+ radioRxActiveStatus INTEGER,
+ radioTxActiveStatus INTEGER,
+ radioCableOpenAlarm AlarmStatus,
+ radioCableShortAlarm AlarmStatus,
+ radioInvalidFrequencyAlarm AlarmStatus,
+ radioBaseBandRxAlarm AlarmStatus,
+ radioModulatorFailAlarm AlarmStatus,
+ radioDemodulatorFailAlarm AlarmStatus,
+ radioRxPowerLowAlarm AlarmStatus,
+ radioTxPowerLowAlarm AlarmStatus,
+ radioRemDemodulatorFailAlarm AlarmStatus,
+ radioVcoFailAlarm AlarmStatus,
+ radioRxIFAgcAlarm AlarmStatus,
+ radioTxIFAgcAlarm AlarmStatus,
+ radioIduOduCommunicationAlarm AlarmStatus,
+ radioOduIduCommunicationAlarm AlarmStatus,
+ radioLocalOduAlarmSynthesis AlarmStatus,
+ radioRemoteOduAlarmSynthesis AlarmStatus,
+ radioConfigMismatchAlarm AlarmStatus,
+ radioConfigAlarmReason ConfigMismatchReason,
+ radioRxQualityLowAlarm AlarmStatus,
+ radioRxQualityWarningAlarm AlarmStatus,
+ radioXpd Integer32
+ }
+
+ radioCurrentDuplexFrequency OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Spacing between transmitted and received frequency in KHz."
+ ::= {radioStatusEntry 1}
+
+ radioTxChannelSpacing OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Half of transmitted signal channel spacing in KHz."
+ ::= {radioStatusEntry 2}
+
+ radioPrx OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Received power level (dBm)."
+ ::= {radioStatusEntry 3}
+
+ radioPtx OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Transmitted power level (dBm)."
+ ::= {radioStatusEntry 4}
+
+ radioNormalizedMse OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Normalized MSE (Mean Squared Error) is an indicator of the Signal
+ to Noise (S/N) ratio. It's in 0.1 dB steps"
+ ::= {radioStatusEntry 5}
+
+ radioRxActiveStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ cleared (1),
+ active (2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Receiver Active status with associated Severity
+ In 1+1 Hot Standby radio system, only one RX is active.
+ RXs are active in other configurations of the radio system.
+ "
+ ::= {radioStatusEntry 6}
+
+ radioTxActiveStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ cleared (1),
+ active (2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Transmitter Active status with associated Severity.
+ In 1+1 Hot Standby radio system, only one TX is active.
+ TXs are active in other configurations of the radio system.
+ "
+ ::= {radioStatusEntry 7}
+
+ radioCableOpenAlarm OBJECT-TYPE
+ SYNTAX AlarmStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cable connnecting ODU is open: alarm status with associated
+ severity.
+ "
+ ::= {radioStatusEntry 8}
+
+ radioCableShortAlarm OBJECT-TYPE
+ SYNTAX AlarmStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cable connnecting ODU is in short-circuit: alarm status
+ with associated severity.
+ "
+ ::= {radioStatusEntry 9}
+
+ radioInvalidFrequencyAlarm OBJECT-TYPE
+ SYNTAX AlarmStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Invalid frequency alarm with associated severity."
+ ::= {radioStatusEntry 10}
+
+ radioBaseBandRxAlarm OBJECT-TYPE
+ SYNTAX AlarmStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Base Band Rx alarm status with associated severity."
+ ::= {radioStatusEntry 11}
+
+ radioModulatorFailAlarm OBJECT-TYPE
+ SYNTAX AlarmStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Modulator Fail Alarm status with associated severity."
+ ::= {radioStatusEntry 12}
+
+ radioDemodulatorFailAlarm OBJECT-TYPE
+ SYNTAX AlarmStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Demodulator Fail Alarm status with associated severity."
+ ::= {radioStatusEntry 13}
+
+ radioRxPowerLowAlarm OBJECT-TYPE
+ SYNTAX AlarmStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Receiver power low alarm status with associated severity."
+ ::= {radioStatusEntry 14}
+
+ radioTxPowerLowAlarm OBJECT-TYPE
+ SYNTAX AlarmStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Transmitter power low alarm status with associated severity."
+ ::= {radioStatusEntry 15}
+
+ radioRemDemodulatorFailAlarm OBJECT-TYPE
+ SYNTAX AlarmStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Remote Demodulator Fail Alarm status with associated severity."
+ ::= {radioStatusEntry 16}
+
+ radioVcoFailAlarm OBJECT-TYPE
+ SYNTAX AlarmStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "RT VCO fail alarm status with associated severity."
+ ::= {radioStatusEntry 17}
+
+ radioRxIFAgcAlarm OBJECT-TYPE
+ SYNTAX AlarmStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "RT Rx IF AGC fail alarm status with associated severity."
+ ::= {radioStatusEntry 18}
+
+ radioTxIFAgcAlarm OBJECT-TYPE
+ SYNTAX AlarmStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "RT Tx IF AGC fail alarm status with associated severity."
+ ::= {radioStatusEntry 19}
+
+ radioIduOduCommunicationAlarm OBJECT-TYPE
+ SYNTAX AlarmStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Communication from IDU towards ODU is down"
+ ::= {radioStatusEntry 20}
+
+ radioOduIduCommunicationAlarm OBJECT-TYPE
+ SYNTAX AlarmStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Communication from ODU towards IDU is down"
+ ::= {radioStatusEntry 21}
+
+ radioLocalOduAlarmSynthesis OBJECT-TYPE
+ SYNTAX AlarmStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Local ODU alarm synthesis with associated severity."
+ ::= {radioStatusEntry 22}
+
+ radioRemoteOduAlarmSynthesis OBJECT-TYPE
+ SYNTAX AlarmStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Local ODU alarm synthesis alarm status with associated severity."
+ ::= {radioStatusEntry 23}
+
+ radioConfigMismatchAlarm OBJECT-TYPE
+ SYNTAX AlarmStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Config Mismatch alarm status with associated severity and related map."
+ ::= {radioStatusEntry 24}
+
+ radioConfigAlarmReason OBJECT-TYPE
+ SYNTAX ConfigMismatchReason
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Bit map to describe the Config Mismatch Alarm"
+-- DEFVAL { { } }
+ ::= {radioStatusEntry 25}
+
+ radioRxQualityLowAlarm OBJECT-TYPE
+ SYNTAX AlarmStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "High BER Alarm status with associated severity."
+ ::= {radioStatusEntry 26}
+
+ radioRxQualityWarningAlarm OBJECT-TYPE
+ SYNTAX AlarmStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The RX signal is close to cause errors on payload."
+ ::= {radioStatusEntry 27}
+
+ radioXpd OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cross-Polarization Discrimination, in tenths of dB, is the
+ difference between the received signal power of the
+ co-polarized main beam, and it componemt received on the
+ cross-polarized signal.
+ This object shows an extimated value of the XPD performed by
+ the cross-polarization interference canceller (XPIC).
+ This means that the measure is reliable if:
+ - XPIC is on (linkType is radio2p0Xpic(4), or radio2p2XpicHS(5),
+ or radio2p2XpicFD(6))
+ - Alarm radioDemodulatorFailAlarm is cleared.
+ - XPD is not too high, since without cross-polar interference
+ the canceller is not able to works well. Basically, in this
+ condition, the extimated XPD is greater than the real one.
+ "
+ ::= {radioStatusEntry 28}
+--
+------- End of radioStatusTable
+
+--
+-- MAINTENANCE TABLE
+--
+
+------- Begin of radioMaintTable
+--
+ radioMaintTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF RadioMaintEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table with Command for maintenance of radio branch.
+ Objects in this table is not persistent. An Instance of this
+ table is created on creation of radioBranchEntry"
+ ::= {radioSystem 13}
+
+ radioMaintEntry OBJECT-TYPE
+ SYNTAX RadioMaintEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Radio branch Maintenance record."
+ INDEX {radioIndex}
+ ::= {radioMaintTable 1}
+
+ RadioMaintEntry ::=
+ SEQUENCE {
+ radioTxStatus INTEGER,
+ radioCarrierOnly INTEGER,
+ radioLoop INTEGER,
+ radioRFLoopTestResult INTEGER,
+ radioRFLoopTestPercTime INTEGER,
+ radioRtPsuOff INTEGER,
+ radioLom INTEGER,
+ radioXpic INTEGER
+ }
+
+ radioTxStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ transmitterOff (1),
+ transmitterOn (2),
+ permanentOff (3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Transmitter status control.
+ The value transmitterOff(1) is related to a manual operation.
+ The value permanentOff(3) is persistent across restart.
+ "
+ DEFVAL {transmitterOn}
+ ::= {radioMaintEntry 1}
+
+ radioCarrierOnly OBJECT-TYPE
+ SYNTAX INTEGER {
+ carrierOnlyOff (1),
+ carrierOnlyOn (2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Carrier only transmission control."
+ DEFVAL {carrierOnlyOff}
+ ::= {radioMaintEntry 2}
+
+ radioLoop OBJECT-TYPE
+ SYNTAX INTEGER {
+ loopOff (1),
+ rfLoop (2),
+ iqLoop (3),
+ baseBandLoop (4),
+ rfLoopAtFixedMod (6),
+ baseBandLoopEthSquelch (7),
+ rfLoopAtFixedModEthSquelch(8),
+ iqloopEthSquelch (9)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enables/disables the Radio Branch loops."
+ DEFVAL {loopOff}
+ ::= {radioMaintEntry 3}
+
+ radioRFLoopTestResult OBJECT-TYPE
+ SYNTAX INTEGER {
+ testNone (0),
+ testRunning (1),
+ testNotPossible (2),
+ testPassed (3),
+ testFail (4),
+ testInterrupted (5)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Radio branch RT loop test result."
+ DEFVAL {testNone}
+ ::= {radioMaintEntry 4}
+
+ radioRFLoopTestPercTime OBJECT-TYPE
+ SYNTAX INTEGER (0..100)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Radio branch RT loop test time percentage"
+ ::= {radioMaintEntry 5}
+
+ radioRtPsuOff OBJECT-TYPE
+ SYNTAX INTEGER {
+ rtPsuOff (1),
+ rtPsuOn (2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "It switches on/off the Rt power supply"
+ DEFVAL {rtPsuOn}
+ ::= {radioMaintEntry 6}
+
+ radioLom OBJECT-TYPE
+ SYNTAX INTEGER {
+ disable (1),
+ enable (2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "It is used to enable the IP packet forwarding towards Radio."
+ DEFVAL {disable}
+ ::= {radioMaintEntry 7}
+
+ radioXpic OBJECT-TYPE
+ SYNTAX INTEGER {
+ disable (1),
+ enable (2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable of the cross polarization interference cancellation of this
+ radio. The value disable is tied to a manual operation
+ (ManOpRecord). This object is applicable only if thiis radio
+ belongs to a 2+0 XPIC or 2+2 XPIC link."
+ ::= {radioMaintEntry 8}
+
+--
+------- End of radioMaintTable
+
+------- Begin of radioFrequencyTable
+--
+ radioFrequencyTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF RadioFreqEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Availables channels for selected channel spacing and modulation
+ (see leaf radioFreqTableSelection)."
+ ::= {radioSystem 14}
+
+ radioFreqTabEntry OBJECT-TYPE
+ SYNTAX RadioFreqEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "RadioFreqTab record."
+ INDEX {radioIndex, radioFreqChannelId}
+ ::= {radioFrequencyTable 1}
+
+ RadioFreqEntry ::=
+ SEQUENCE {
+ radioFreqChannelId Integer32,
+ radioFreqChannelNum Integer32,
+ radioFreqValue Integer32
+ }
+
+ radioFreqChannelId OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index of the table"
+ ::= {radioFreqTabEntry 1}
+
+ radioFreqChannelNum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Available channel number."
+ ::= {radioFreqTabEntry 2}
+
+ radioFreqValue OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Frequency related to radioFreqChannelNum."
+ ::= {radioFreqTabEntry 3}
+--
+------- End of radioFrequencyTable
+
+------- Begin of radioDuplexFrequencyTable
+--
+ radioDuplexFrequencyTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF RadioDuplexFreqEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table with available duplex frequencies. Duplex frequency is
+ the absolute value of difference between RX and TX frequency."
+ ::= {radioSystem 15}
+
+ radioDuplexFreqEntry OBJECT-TYPE
+ SYNTAX RadioDuplexFreqEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Duplex Frequency entry. There is an entry for each available
+ duplex frequency."
+ INDEX {radioIndex, radioDuplexFreqId}
+ ::= {radioDuplexFrequencyTable 1}
+
+ RadioDuplexFreqEntry ::=
+ SEQUENCE {
+ radioDuplexFreqId Integer32,
+ radioDuplexFreqValue Integer32
+ }
+
+ radioDuplexFreqId OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index of the table."
+ ::= {radioDuplexFreqEntry 1}
+
+ radioDuplexFreqValue OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Duplex frequency in KHz."
+ ::= {radioDuplexFreqEntry 2}
+--
+------- End of radioDuplexFrequencyTable
+
+------- Begin of radioModulationTable
+--
+ radioModulationTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF RadioModulationEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "List of modulations related to channel spacing."
+ ::= {radioSystem 16}
+
+ radioModulationEntry OBJECT-TYPE
+ SYNTAX RadioModulationEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "radioModulation record."
+ INDEX {radioIndex, radioChannelSpacing}
+ ::= {radioModulationTable 1}
+
+ RadioModulationEntry ::=
+ SEQUENCE {
+ radioChannelSpacing ChannelSpacing,
+ radioModulationMap ModulationMap,
+ radioRefModulationMap ModulationMap
+ }
+
+ radioChannelSpacing OBJECT-TYPE
+ SYNTAX ChannelSpacing
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object identifies the channel spacing."
+ ::= {radioModulationEntry 1}
+
+ radioModulationMap OBJECT-TYPE
+ SYNTAX ModulationMap
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "List of modulations in the radioChanSpacing"
+ ::= {radioModulationEntry 2}
+
+ radioRefModulationMap OBJECT-TYPE
+ SYNTAX ModulationMap
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "List of modulations that can be selected as reference
+ in the radioChanSpacingId"
+ ::= {radioModulationEntry 3}
+--
+------- End of radioModulationTable
+
+------- Begin of linkStatusTable
+--
+ linkStatusTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF LinkStatusEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table with LinkStatusEntry."
+ ::= {radioSystem 17}
+
+ linkStatusEntry OBJECT-TYPE
+ SYNTAX LinkStatusEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Link status entry"
+ INDEX {linkIndex,
+ linkPolIndex }
+ ::= {linkStatusTable 1}
+
+ LinkStatusEntry ::=
+ SEQUENCE{
+ linkPolIndex INTEGER,
+ linkAcmRxProfile Integer32,
+ linkAcmTxProfile Integer32,
+ linkAcmRxProfileLabel DisplayString,
+ linkAcmTxProfileLabel DisplayString,
+ linkAcmRxModulation BitsPerSymbol,
+ linkAcmTxModulation BitsPerSymbol,
+ linkAcmRxCode INTEGER,
+ linkAcmTxCode INTEGER,
+ linkTxETHCapacity Integer32,
+ linkRxETHCapacity Integer32,
+ linkTxTDMCapacity Integer32,
+ linkRxTDMCapacity Integer32,
+ linkRescueModulation BitsPerSymbol,
+ linkReducedCapacityAlarm AlarmStatus,
+ linkLinkTelemetryFailAlarm AlarmStatus,
+ linkIdMismatchAlarm AlarmStatus,
+ linkRadioEocAlarm AlarmStatus,
+ linkSetupMismatchAlarm AlarmStatus,
+ linkRescueSetupAlarm AlarmStatus,
+ linkXpicProcedureBlockAlarm AlarmStatus,
+ linkXpicRemTxOffAlarm AlarmStatus,
+ linkRemoteIduAlarmSynthesis AlarmStatus,
+ linkNotMatchingRadiosAlarm AlarmStatus,
+ linkConfigurationInProgress INTEGER,
+ linkXpd Integer32
+ }
+
+ linkPolIndex OBJECT-TYPE
+ SYNTAX INTEGER (1..2)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object identifies the radio polarization. In XPIC radio link
+ identifies one of the polarizations."
+ ::= {linkStatusEntry 1}
+
+ linkAcmRxProfile OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reports the ACM profile number in use in the radio Rx.
+ It is the linkAcmProfileId of linkAcmTable.
+ Label is linkAcmProfileLabel from linkAcmTable"
+ ::= {linkStatusEntry 2}
+
+ linkAcmTxProfile OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reports the ACM profile number in use in the radio Tx.
+ It is the linkAcmProfileId of linkAcmTable.
+ Label is linkAcmProfileLabel from linkAcmTable"
+ ::= {linkStatusEntry 3}
+
+ linkAcmRxProfileLabel OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..32))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "ASCII string used to describe current acm rx profile"
+ ::= {linkStatusEntry 4}
+
+ linkAcmTxProfileLabel OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..32))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "ASCII string used to describe current acm tx profile"
+ ::= {linkStatusEntry 5}
+
+ linkAcmRxModulation OBJECT-TYPE
+ SYNTAX BitsPerSymbol
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object is the type of modulation of the Rx profile in use."
+ ::= {linkStatusEntry 6}
+
+ linkAcmTxModulation OBJECT-TYPE
+ SYNTAX BitsPerSymbol
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object is the type of modulation of the Tx profile in use."
+ ::= {linkStatusEntry 7}
+
+ linkAcmRxCode OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown (0),
+ normal (1),
+ strong (2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object is the type of codificator of the Rx profile in use."
+ ::= {linkStatusEntry 8}
+
+ linkAcmTxCode OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown (0),
+ normal (1),
+ strong (2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object is the type of codificator of the Tx profile in use."
+ ::= {linkStatusEntry 9}
+
+ linkTxETHCapacity OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reports (in Kbits/sec) the transmitted payload
+ capacity used by the Ethernet"
+ DEFVAL { 0 }
+ ::= {linkStatusEntry 10}
+
+ linkRxETHCapacity OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reports (in Kbits/sec) the received payload capacity
+ used by the Ethernet"
+ DEFVAL { 0 }
+ ::= {linkStatusEntry 11}
+
+ linkTxTDMCapacity OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reports the capacity in kbit/sec reserved to TDM
+ tributaries in tx ACM profile."
+ DEFVAL { 0 }
+ ::= {linkStatusEntry 12}
+
+ linkRxTDMCapacity OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reports the capacity in kbit/sec reserved to TDM
+ tributaries in rx ACM profile."
+ DEFVAL { 0 }
+ ::= {linkStatusEntry 13}
+
+ linkRescueModulation OBJECT-TYPE
+ SYNTAX BitsPerSymbol
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object is the modulation used when the remote terminal is
+ unreachable, ie traffic on radio link is down."
+ DEFVAL { bps4QAM }
+ ::= {linkStatusEntry 14}
+
+ linkReducedCapacityAlarm OBJECT-TYPE
+ SYNTAX AlarmStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The equipment works in reduced capacity"
+ ::= {linkStatusEntry 15}
+
+ linkLinkTelemetryFailAlarm OBJECT-TYPE
+ SYNTAX AlarmStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Fail of link telemetry communication channel with associated
+ Severity"
+ ::= {linkStatusEntry 16}
+
+ linkIdMismatchAlarm OBJECT-TYPE
+ SYNTAX AlarmStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Link Identification Alarm with associated Severity"
+ ::= {linkStatusEntry 17}
+
+ linkRadioEocAlarm OBJECT-TYPE
+ SYNTAX AlarmStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Fail of Radio Eoc link communication channel with associated
+ Severity"
+ ::= {linkStatusEntry 18}
+
+ linkSetupMismatchAlarm OBJECT-TYPE
+ SYNTAX AlarmStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The local setup doesn't match the setup of remote terminal"
+ ::= {linkStatusEntry 19}
+
+ linkRescueSetupAlarm OBJECT-TYPE
+ SYNTAX AlarmStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The equipment is using the setup relative to the rescue modulation"
+ ::= {linkStatusEntry 20}
+
+ linkXpicProcedureBlockAlarm OBJECT-TYPE
+ SYNTAX AlarmStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Only for XPIC equipment configurations.
+ Equipment Controller XPIC procedure Alarm control with associated
+ Severity"
+ ::= {linkStatusEntry 21}
+
+ linkXpicRemTxOffAlarm OBJECT-TYPE
+ SYNTAX AlarmStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Only for XPIC equipment configurations.
+ Remote TX OFF command with associated Severity"
+ ::= {linkStatusEntry 22}
+
+ linkRemoteIduAlarmSynthesis OBJECT-TYPE
+ SYNTAX AlarmStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Synthesis of the remote IDU alarms"
+ ::= {linkStatusEntry 23}
+
+ linkNotMatchingRadiosAlarm OBJECT-TYPE
+ SYNTAX AlarmStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Radios of the link does not have matched parameters."
+ ::= {linkStatusEntry 24}
+
+ linkConfigurationInProgress OBJECT-TYPE
+ SYNTAX INTEGER {
+ cleared (1),
+ active (2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The link is being configured and the table linkSettingsTable is
+ not available for modifying parameters.
+ "
+ ::= {linkStatusEntry 25}
+
+ linkXpd OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "Cross-Polarization Discrimination, in tenths of dB, is the
+ difference between the received signal power of the
+ co-polarized main beam, and it componemt received on the
+ cross-polarized signal.
+ This object shows an extimated value of the XPD performed by
+ the cross-polarization interference canceller (XPIC).
+ This means that the measure is reliable if:
+ - XPIC is on (linkType is radio2p0Xpic(4), or radio2p2XpicHS(5),
+ or radio2p2XpicFD(6))
+ - Alarm radioDemodulatorFailAlarm is cleared.
+ - XPD is not too high, since without cross-polar interference
+ the canceller is not able to works well. Basically, in this
+ condition, the extimated XPD is greater than the real one.
+ "
+ ::= {linkStatusEntry 26}
+
+--
+------- End of linkStatusTable
+
+------- Begin of linkTfcTable
+--
+ linkTfcTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF LinkTfcEntry
+ MAX-ACCESS not-accessible
+ STATUS deprecated
+ DESCRIPTION
+ "Transmitter Fail Check feature. In 1+1 HS configuration, the
+ radio terminal that doesn't receive signals on both receivers,
+ requests the remote transmitter switch.
+
+ This table was deprecated and replaced by linkTfcV2Table.
+ It is a view of the rows of the linkTfcV2Table with the same
+ linkIndex and linkPolIndex equal to 1, in order to ensure
+ compatibility with old SNMP managers.
+ "
+ ::= {radioSystem 18}
+
+ linkTfcEntry OBJECT-TYPE
+ SYNTAX LinkTfcEntry
+ MAX-ACCESS not-accessible
+ STATUS deprecated
+ DESCRIPTION
+ "Radio link TFC entry."
+ INDEX {linkIndex}
+ ::= {linkTfcTable 1}
+
+ LinkTfcEntry ::=
+ SEQUENCE {
+ linkTfcAction INTEGER,
+ linkTfcControl INTEGER,
+ linkTfcWatchWindow INTEGER,
+ linkTfcAlarmThreshold INTEGER,
+ linkTfcAlarm AlarmStatus,
+ linkTfcRowStatus RowStatus
+ }
+
+ linkTfcAction OBJECT-TYPE
+ SYNTAX INTEGER {
+ notActive (0),
+ reset (1)
+ }
+ MAX-ACCESS read-create
+ STATUS deprecated
+ DESCRIPTION
+ "reset: to clear the forced switch generated by Trasmission Fail
+ Check algorithm (only if 1+1 configuration and ISO system)."
+ ::= {linkTfcEntry 1}
+
+ linkTfcControl OBJECT-TYPE
+ SYNTAX INTEGER {
+ disable (1),
+ enable (2)
+ }
+ MAX-ACCESS read-create
+ STATUS deprecated
+ DESCRIPTION
+ "It enables the Tx switch from remote equipment (only if 1+1
+ configuration and ISO system)."
+ DEFVAL {disable}
+ ::= {linkTfcEntry 2}
+
+ linkTfcWatchWindow OBJECT-TYPE
+ SYNTAX INTEGER (1..300)
+ MAX-ACCESS read-create
+ STATUS deprecated
+ DESCRIPTION
+ "Watch Window (in seconds) related to Trasmission Fail Check
+ algorithm (only if 1+1 configuration and ISO system)."
+ DEFVAL { 60 }
+ ::= {linkTfcEntry 3}
+
+ linkTfcAlarmThreshold OBJECT-TYPE
+ SYNTAX INTEGER (1..60)
+ MAX-ACCESS read-create
+ STATUS deprecated
+ DESCRIPTION
+ "Alarm Threshold (number of seconds with both remote RX in fail)
+ related to Trasmission Fail Check algorithm (only if 1+1
+ configuration and ISO system)."
+ DEFVAL { 10 }
+ ::= {linkTfcEntry 4}
+
+ linkTfcAlarm OBJECT-TYPE
+ SYNTAX AlarmStatus
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "Transmission switch alarm generated by Trasmission Fail Check
+ algorithm (only if 1+1 configuration and ISO system)."
+ ::= {linkTfcEntry 5}
+
+ linkTfcRowStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS deprecated
+ DESCRIPTION
+ "Status of this conceptual row in linkTfcTable."
+ ::= {linkTfcEntry 6}
+
+--
+------- End of linkTfcTable
+
+------- Begin of linkMaintTable
+--
+ linkMaintTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF LinkMaintEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table with commands for maintenance of radio link.
+ Objects in this table is not persistent. An Instance of this
+ table is created on creation of linkStatusEntry"
+ ::= {radioSystem 19}
+
+ linkMaintEntry OBJECT-TYPE
+ SYNTAX LinkMaintEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Radio link maintenance entry."
+ INDEX {linkIndex,
+ linkPolIndex}
+ ::= {linkMaintTable 1}
+
+ LinkMaintEntry ::=
+ SEQUENCE {
+ linkBerStart INTEGER,
+ linkBaseBandLom INTEGER,
+ linkFadeMarginMeasure INTEGER,
+ linkXpicControlProcedureReset INTEGER
+ }
+
+ linkBerStart OBJECT-TYPE
+ SYNTAX INTEGER {
+ restart (1),
+ stop (2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Stop, Start (resetting errors and counters) the pattern.
+ This item is linked to a manual operation (ManOpRecord) instance."
+ DEFVAL {stop}
+ ::= {linkMaintEntry 1}
+
+ linkBaseBandLom OBJECT-TYPE
+ SYNTAX INTEGER {
+ disable (1),
+ enable (2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "It is used to enable the IP packet forwarding towards modems.
+ This item is linked to a manual operation (ManOpRecord) instance."
+ DEFVAL {disable}
+ ::= {linkMaintEntry 2}
+
+ linkFadeMarginMeasure OBJECT-TYPE
+ SYNTAX INTEGER {
+ disable (1),
+ enable (2)
+ }
+ MAX-ACCESS read-write
+ STATUS deprecated
+ DESCRIPTION
+ "Set by manager to start/stop fade margin measure.
+ This item is linked to a manual operation (ManOpRecord) instance.
+ This object is deprecated and replaced by fadeMarginMeasure.
+ "
+ DEFVAL { disable }
+ ::= {linkMaintEntry 3}
+
+ linkXpicControlProcedureReset OBJECT-TYPE
+ SYNTAX INTEGER {
+ notActive (0),
+ reset (1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Set by manager to reset the XPIC control procedure after a
+ blocking action."
+ DEFVAL {notActive}
+ ::= {linkMaintEntry 4}
+
+--
+------- End of linkMaintTable
+
+------- Begin of linkBerTable
+--
+ linkBerTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF LinkBerEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table with Command to estimate BER of radio equipment.
+ Every objects in this table is not persistent. An Instance of this
+ table is created on creation of linkStatusEntry"
+ ::= {radioSystem 20}
+
+ linkBerEntry OBJECT-TYPE
+ SYNTAX LinkBerEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Radio equipment BER estimate record."
+ INDEX {linkIndex,
+ linkPolIndex}
+ ::= {linkBerTable 1}
+
+ LinkBerEntry ::=
+ SEQUENCE {
+ linkBerErrorCounterH Counter32,
+ linkBerErrorCounterL Counter32,
+ linkBerDataCounterH Counter32,
+ linkBerDataCounterL Counter32,
+ linkBerSyncLossAlarm AlarmStatus,
+ linkBerSyncLossAlarmCounter Integer32,
+ linkBerElapsedTime Integer32
+ }
+
+ linkBerErrorCounterH OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "High 32 bit part of the 64 bit error counter. Bit 32-63."
+ ::= {linkBerEntry 1}
+
+ linkBerErrorCounterL OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Low 32 bit part of the 64 bit error counter. Bit 0-31."
+ ::= {linkBerEntry 2}
+
+ linkBerDataCounterH OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "High 32 bit part of the 64 bit data counter. Bit 32-63."
+ ::= {linkBerEntry 3}
+
+ linkBerDataCounterL OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Low 32 bit part of the 64 bit data counter. Bit 0-31."
+ ::= {linkBerEntry 4}
+
+ linkBerSyncLossAlarm OBJECT-TYPE
+ SYNTAX AlarmStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "BER sync loss alarm."
+ ::= {linkBerEntry 5}
+
+ linkBerSyncLossAlarmCounter OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "BER sync loss events counter."
+ ::= {linkBerEntry 6}
+
+ linkBerElapsedTime OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "BER measure elapsed time."
+ ::= {linkBerEntry 7}
+
+--
+------- End of linkBerTable
+
+------- Begin of linkAcmTable
+--
+ linkAcmTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF LinkAcmEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table with link records."
+ ::= {radioSystem 21}
+
+ linkAcmEntry OBJECT-TYPE
+ SYNTAX LinkAcmEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "ACM entries."
+ INDEX {linkIndex, linkPolIndex, linkAcmProfileId}
+ ::= {linkAcmTable 1}
+
+ LinkAcmEntry ::=
+ SEQUENCE {
+ linkAcmProfileId Integer32,
+ linkAcmProfileModulation BitsPerSymbol,
+ linkAcmProfileCode INTEGER,
+ linkAcmProfileCapacity Integer32,
+ linkAcmProfileLabel DisplayString,
+ linkAcmMaxTDMCapacity Integer32,
+ linkAcmPowerScaling Integer32,
+ linkAcmProfileEnable INTEGER,
+ linkAcmDownshiftThreshold Integer32,
+ linkAcmUpshiftThreshold Integer32,
+ linkAcmActiveProfile INTEGER,
+ linkAcmTDMCapacity Integer32,
+ linkAcmETHCapacity Integer32,
+ linkAcmAtpcRxPowerScaling Integer32,
+ linkAcmPowerRange Integer32
+ }
+
+ linkAcmProfileId OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object identifies the profile number for the radio selected
+ by the object linkAcmId."
+ ::= {linkAcmEntry 1}
+
+ linkAcmProfileModulation OBJECT-TYPE
+ SYNTAX BitsPerSymbol
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object is the modulation of the profile."
+ ::= {linkAcmEntry 2}
+
+ linkAcmProfileCode OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal (1),
+ strong (2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object is the type of codificator of the profile."
+ ::= {linkAcmEntry 3}
+
+ linkAcmProfileCapacity OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object is used to contain total capacity of profile
+ (in kbits/sec)."
+ ::= {linkAcmEntry 4}
+
+ linkAcmProfileLabel OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..32))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ASCII string used to assign a name to profile."
+ ::= {linkAcmEntry 5}
+
+ linkAcmProfileEnable OBJECT-TYPE
+ SYNTAX INTEGER {
+ disable (1),
+ enable (2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The object is used to contain if the use of this profile is
+ enabled or disabled"
+ DEFVAL {enable}
+ ::= {linkAcmEntry 6}
+
+ linkAcmMaxTDMCapacity OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "This object reports the maximum capacity that can
+ be assigned to the TDM traffic.
+ The capacity is specified in number of E1 (2Mbit/s).
+
+ This object has been superseded by linkE1vsSTM1CapacityTable.
+ "
+ DEFVAL {0}
+ ::= {linkAcmEntry 7}
+
+ linkAcmPowerScaling OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "This object contains the difference (in eighth of dB) between the
+ TX power at this profile modulation and the TX power at the
+ reference modulation. The power scaling value is achieved from the
+ table linkPtxProfileTable.
+ This object is deprecated: see combinedRadioPowerScalingTable."
+ ::= {linkAcmEntry 8}
+
+ linkAcmDownshiftThreshold OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The object is used to contain the downshift threshold in dB/10."
+ ::= {linkAcmEntry 9}
+
+ linkAcmUpshiftThreshold OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The object is used to contain the upshift threshold in dB/10."
+ ::= {linkAcmEntry 10}
+
+ linkAcmActiveProfile OBJECT-TYPE
+ SYNTAX INTEGER {
+ cleared (1),
+ activeRx (2),
+ activeTx (3),
+ activeBoth (4)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object is used to contain the active status of this profile.
+ The value of the object is related to linkAcmRxProfile
+ and linkAcmTxProfile of the LinkStatusEntry."
+ DEFVAL {cleared}
+ ::= {linkAcmEntry 11}
+
+ linkAcmTDMCapacity OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reports current TDM capacity (in kbits/sec)
+ of the profile."
+ ::= {linkAcmEntry 12}
+
+ linkAcmETHCapacity OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reports current ETH capacity (in Kbits/sec) of
+ the profile."
+ ::= {linkAcmEntry 13}
+
+ linkAcmAtpcRxPowerScaling OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "This object contains the difference (in eighth of dB) between the
+ ATPC RX level thresholds at this profile modulation and the ATPC
+ RX level thresholds at the upper modulation.
+ This object is deprecated: see combinedRadioPowerScalingTable."
+ ::= {linkAcmEntry 14}
+
+ linkAcmPowerRange OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "This object contains (in dB) the current value of ATPC range.
+ This object is deprecated: see combinedRadioPowerScalingTable."
+ ::= {linkAcmEntry 15}
+
+--
+------- End of linkAcmTable
+
+------- Begin of linkProTable
+--
+ linkProTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF LinkProEntry
+ MAX-ACCESS not-accessible
+ STATUS deprecated
+ DESCRIPTION
+ "A list of protection link entries.
+
+ This table was deprecated and replaced by linkProV2Table.
+ It is a view of the rows of the linkProV2Table with the same
+ linkIndex and linkPolIndex equal to 1, in order to ensure
+ compatibility with old SNMP managers
+ "
+ ::= {radioSystem 22}
+
+ linkProEntry OBJECT-TYPE
+ SYNTAX LinkProEntry
+ MAX-ACCESS not-accessible
+ STATUS deprecated
+ DESCRIPTION
+ "An entry containing management information applicable to a
+ protected link.
+ "
+ INDEX {linkIndex}
+ ::= {linkProTable 1}
+
+ LinkProEntry ::=
+ SEQUENCE {
+ linkProProtectionTxChIdx Integer32,
+ linkProProtectionRxChIdx Integer32,
+ linkProTxWtrTime INTEGER,
+ linkProRxWtrTime INTEGER,
+ linkProTxSwitchedChIdx Integer32,
+ linkProRxSwitchedChIdx Integer32,
+ linkProTxRevertive INTEGER,
+ linkProRxRevertive INTEGER,
+ linkProExtraTraffic INTEGER,
+ linkProRowStatus RowStatus
+ }
+
+ linkProProtectionTxChIdx OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-create
+ STATUS deprecated
+ DESCRIPTION
+ "This object identifies the tx protection channel
+ of a protected link. This object is not applicable
+ in case of not-revertive protection. For N+1 links
+ a value different from zero must be set.
+ "
+ DEFVAL {0}
+ ::= {linkProEntry 1}
+
+ linkProProtectionRxChIdx OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-create
+ STATUS deprecated
+ DESCRIPTION
+ "This object identifies the rx protection channel
+ of a protected link. This object is not applicable
+ in case of not-revertive protection. For N+1 links
+ a value different from zero must be set.
+ "
+ DEFVAL {0}
+ ::= {linkProEntry 2}
+
+ linkProTxWtrTime OBJECT-TYPE
+ SYNTAX INTEGER (0..12)
+ MAX-ACCESS read-create
+ STATUS deprecated
+ DESCRIPTION
+ "It defines the Wait Time (in minutes) to Restore in transmission
+ when revertive protection is enabled. Zero value means no switch.
+ If switch is not supported or protection is not revertive,
+ a value different from zero cannot be set.
+ "
+ DEFVAL {0}
+ ::= {linkProEntry 3}
+
+ linkProRxWtrTime OBJECT-TYPE
+ SYNTAX INTEGER (0..12)
+ MAX-ACCESS read-create
+ STATUS deprecated
+ DESCRIPTION
+ "It defines the Wait Time (in minutes) to Restore in reception when
+ revertive protection is enabled. Zero value means no switch.
+ If switch is not supported or protection is not revertive,
+ a value different from zero cannot be set.
+ "
+ DEFVAL {0}
+ ::= {linkProEntry 4}
+
+ linkProTxSwitchedChIdx OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "This object reports the index of tx channel switched to protection.
+ This object is applicable only for N+1 protection schema.
+ "
+ DEFVAL {0}
+ ::= {linkProEntry 5}
+
+ linkProRxSwitchedChIdx OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "This object reports the index of rx channel switched to protection.
+ This object is applicable only for N+1 protection schema.
+ "
+ DEFVAL {0}
+ ::= {linkProEntry 6}
+
+ linkProTxRevertive OBJECT-TYPE
+ SYNTAX INTEGER {
+ disable (1),
+ enable (2)
+ }
+ MAX-ACCESS read-create
+ STATUS deprecated
+ DESCRIPTION
+ "It defines if tx protection is revertive or not revertive.
+ In case of N+1 protection, protection is always revertive.
+ "
+ DEFVAL {disable}
+ ::= {linkProEntry 7}
+
+ linkProRxRevertive OBJECT-TYPE
+ SYNTAX INTEGER {
+ disable (1),
+ enable (2)
+ }
+ MAX-ACCESS read-create
+ STATUS deprecated
+ DESCRIPTION
+ "It defines if rx protection is revertive or not revertive.
+ In case of N+1 protection, protection is always revertive.
+ "
+ DEFVAL {disable}
+ ::= {linkProEntry 8}
+
+ linkProExtraTraffic OBJECT-TYPE
+ SYNTAX INTEGER {
+ disable (1),
+ enable (2)
+ }
+ MAX-ACCESS read-create
+ STATUS deprecated
+ DESCRIPTION
+ "This object enables or disables the transfer of extra traffic
+ on the protection channel in a N+1 link. This object must be
+ set to disabled in case of architectures different for N+1.
+ "
+ DEFVAL {disable}
+ ::= {linkProEntry 9}
+
+ linkProRowStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS deprecated
+ DESCRIPTION
+ "Status of this conceptual row in linkProTable.
+ "
+ ::= {linkProEntry 10}
+
+--
+------- End of linkProTable
+
+------- Begin of linkProMaintTable
+--
+ linkProMaintTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF LinkProMaintEntry
+ MAX-ACCESS not-accessible
+ STATUS deprecated
+ DESCRIPTION
+ "A list of maintenance commands for protected links.
+ A row in this table is added on creation of a row
+ in linkProTable.
+
+ This table was deprecated and replaced by linkProMaintV2Table.
+ It is a view of the rows of the linkProMaintV2Table with the same
+ linkIndex and linkPolIndex equal to 1, in order to ensure
+ compatibility with old SNMP managers
+ "
+ ::= {radioSystem 23}
+
+ linkProMaintEntry OBJECT-TYPE
+ SYNTAX LinkProMaintEntry
+ MAX-ACCESS not-accessible
+ STATUS deprecated
+ DESCRIPTION
+ "An entry containing maintenance commands applicable to a
+ protected link.
+ "
+ INDEX {linkIndex}
+ ::= {linkProMaintTable 1}
+
+ LinkProMaintEntry ::=
+ SEQUENCE {
+ linkProMaintTxLockout INTEGER,
+ linkProMaintRxLockout INTEGER,
+ linkProMaintTxForced Integer32,
+ linkProMaintRxForced Integer32,
+ linkProMaintTxWtrReset INTEGER,
+ linkProMaintRxWtrReset INTEGER
+ }
+
+ linkProMaintTxLockout OBJECT-TYPE
+ SYNTAX INTEGER {
+ disable (1),
+ enable (2)
+ }
+ MAX-ACCESS read-write
+ STATUS deprecated
+ DESCRIPTION
+ "Command to enable/disable tx lockout. This object
+ is applicable only in case of N+1 protections.
+ "
+ DEFVAL {disable}
+ ::= {linkProMaintEntry 1}
+
+ linkProMaintRxLockout OBJECT-TYPE
+ SYNTAX INTEGER {
+ disable (1),
+ enable (2)
+ }
+ MAX-ACCESS read-write
+ STATUS deprecated
+ DESCRIPTION
+ "Command to enable/disable rx lockout. This object
+ is applicable only in case of N+1 protections.
+ "
+ DEFVAL {disable}
+ ::= {linkProMaintEntry 2}
+
+ linkProMaintTxForced OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS deprecated
+ DESCRIPTION
+ "Command to force switch to a given
+ transmission channel. Zero value means no
+ switch.
+ "
+ DEFVAL {0}
+ ::= {linkProMaintEntry 3}
+
+ linkProMaintRxForced OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS deprecated
+ DESCRIPTION
+ "Command to force switch to a given
+ receiving channel. Zero value means no
+ switch.
+ "
+ DEFVAL {0}
+ ::= {linkProMaintEntry 4}
+
+ linkProMaintTxWtrReset OBJECT-TYPE
+ SYNTAX INTEGER {
+ notActive (1),
+ on (2)
+ }
+ MAX-ACCESS read-write
+ STATUS deprecated
+ DESCRIPTION
+ "Clear wait time to restore making the revertive
+ path immediately available.
+ "
+ DEFVAL {notActive}
+ ::= {linkProMaintEntry 5}
+
+ linkProMaintRxWtrReset OBJECT-TYPE
+ SYNTAX INTEGER {
+ notActive (1),
+ on (2)
+ }
+ MAX-ACCESS read-write
+ STATUS deprecated
+ DESCRIPTION
+ "Clear wait time to restore making the revertive
+ path immediately available.
+ "
+ DEFVAL {notActive}
+ ::= {linkProMaintEntry 6}
+
+
+--
+------- End of linkProMaintTable
+
+------- Begin of linkCapabilitiesTable
+--
+ linkCapabilitiesTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF LinkCapabilitiesEntry
+ MAX-ACCESS not-accessible
+ STATUS deprecated
+ DESCRIPTION
+ "Table with RadioCapabilities entries: there is an entry for each
+ linkTable row.
+ In 1+1 HS and XPIC radio links, this table contains only values
+ supported by both radios.
+ In 1+1 FD radio link, managers have to know the capabilities
+ of each channel. As such, this table is declared deprecated and
+ replaced by combinedRadioCapabilitiesTable."
+ ::= {radioSystem 24}
+
+ linkCapabilitiesEntry OBJECT-TYPE
+ SYNTAX LinkCapabilitiesEntry
+ MAX-ACCESS not-accessible
+ STATUS deprecated
+ DESCRIPTION
+ "LinkCapabilities entry."
+ INDEX {linkIndex}
+ ::= {linkCapabilitiesTable 1}
+
+ LinkCapabilitiesEntry ::=
+ SEQUENCE {
+ linkCapabilitiesCapability RadioCapability,
+ linkCapabilitiesTxMinFrequency Integer32,
+ linkCapabilitiesTxMaxFrequency Integer32,
+ linkCapabilitiesStepFrequency Integer32,
+ linkCapabilitiesMinPtxNominalValue Integer32,
+ linkCapabilitiesMaxPtxNominalValue Integer32,
+ linkCapabilitiesExtendedMinPwr Integer32
+ }
+
+ linkCapabilitiesCapability OBJECT-TYPE
+ SYNTAX RadioCapability
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "Bit map to describe the radio features."
+ ::= {linkCapabilitiesEntry 1}
+
+ linkCapabilitiesTxMinFrequency OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "Minimum of available channel frequency in KHz."
+ ::= {linkCapabilitiesEntry 2}
+
+ linkCapabilitiesTxMaxFrequency OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "Maximum of available channel frequency in KHz."
+ ::= {linkCapabilitiesEntry 3}
+
+ linkCapabilitiesStepFrequency OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "Minimum frequency step in KHz."
+ ::= {linkCapabilitiesEntry 4}
+
+ linkCapabilitiesMinPtxNominalValue OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "Minimum nominal Ptx in dBm."
+ ::= {linkCapabilitiesEntry 5}
+
+ linkCapabilitiesMaxPtxNominalValue OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "Maximum nominal Ptx in dBm."
+ ::= {linkCapabilitiesEntry 6}
+
+ linkCapabilitiesExtendedMinPwr OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "Minimum extended Ptx power for fade margin."
+ ::= {linkCapabilitiesEntry 7}
+--
+------- End of linkCapabilitiesTable
+
+------- Begin of linkFrequencyTable
+--
+ linkFrequencyTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF LinkFreqEntry
+ MAX-ACCESS not-accessible
+ STATUS deprecated
+ DESCRIPTION
+ "Availables channels for selected channel spacing and modulation
+ In 1+1 HS and XPIC radio links, this table contains only values
+ supported by both radios.
+ In 1+1 FD radio link, managers have to know the allowable
+ frequencies of each channel. As such, this table is declared
+ deprecated and replaced by combinedRadioFrequencyTable."
+ ::= {radioSystem 25}
+
+ linkFreqTabEntry OBJECT-TYPE
+ SYNTAX LinkFreqEntry
+ MAX-ACCESS not-accessible
+ STATUS deprecated
+ DESCRIPTION
+ "LinkFreqTab record."
+ INDEX {linkIndex, linkFreqChannelId}
+ ::= {linkFrequencyTable 1}
+
+ LinkFreqEntry ::=
+ SEQUENCE {
+ linkFreqChannelId Integer32,
+ linkFreqChannelNum Integer32,
+ linkFreqValue Integer32
+ }
+
+ linkFreqChannelId OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "Index of the table"
+ ::= {linkFreqTabEntry 1}
+
+ linkFreqChannelNum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "Available channel number."
+ ::= {linkFreqTabEntry 2}
+
+ linkFreqValue OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "Frequency related to linkFreqChannelNum."
+ ::= {linkFreqTabEntry 3}
+--
+------- End of linkFrequencyTable
+
+------- Begin of linkDuplexFrequencyTable
+--
+ linkDuplexFrequencyTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF LinkDuplexFreqEntry
+ MAX-ACCESS not-accessible
+ STATUS deprecated
+ DESCRIPTION
+ "Table with available duplex frequencies. Duplex frequency is
+ the absolute value of difference between RX and TX frequency.
+ In 1+1 HS and XPIC radio links, this table contains only values
+ supported by both radios.
+ In 1+1 FD radio link, managers have to know the allowable
+ duplex frequencies of each channel. As such, this table is declared
+ deprecated and replaced by combinedRadioDuplexFrequencyTable."
+ ::= {radioSystem 26}
+
+ linkDuplexFreqEntry OBJECT-TYPE
+ SYNTAX LinkDuplexFreqEntry
+ MAX-ACCESS not-accessible
+ STATUS deprecated
+ DESCRIPTION
+ "Duplex Frequency entry. For each available duplex frequency"
+ INDEX {linkIndex, linkDuplexFreqId}
+ ::= {linkDuplexFrequencyTable 1}
+
+ LinkDuplexFreqEntry ::=
+ SEQUENCE {
+ linkDuplexFreqId Integer32,
+ linkDuplexFreqValue Integer32
+ }
+
+ linkDuplexFreqId OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "Index of the table."
+ ::= {linkDuplexFreqEntry 1}
+
+ linkDuplexFreqValue OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "Duplex frequency in KHz."
+ ::= {linkDuplexFreqEntry 2}
+--
+------- End of linkDuplexFrequencyTable
+
+------- Begin of linkModulationTable
+--
+ linkModulationTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF LinkModulationEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "List of modulation related to channel spacing.
+ In 1+1 HS and XPIC radio links, this table contains only values
+ supported by both radios.
+ "
+ ::= {radioSystem 27}
+
+ linkModulationEntry OBJECT-TYPE
+ SYNTAX LinkModulationEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "linkModulation record."
+ INDEX {linkIndex, linkChannelSpacing}
+ ::= {linkModulationTable 1}
+
+ LinkModulationEntry ::=
+ SEQUENCE {
+ linkChannelSpacing ChannelSpacing,
+ linkModulationMap ModulationMap,
+ linkRefModulationMap ModulationMap
+ }
+
+ linkChannelSpacing OBJECT-TYPE
+ SYNTAX ChannelSpacing
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object identifies the channel spacing."
+ ::= {linkModulationEntry 1}
+
+ linkModulationMap OBJECT-TYPE
+ SYNTAX ModulationMap
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "List of modulation in the linkChanSpacing"
+ ::= {linkModulationEntry 2}
+
+ linkRefModulationMap OBJECT-TYPE
+ SYNTAX ModulationMap
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "List of modulations that can be selected as reference
+ in the linkChanSpacingId"
+ ::= {linkModulationEntry 3}
+--
+------- End of linkModulationTable
+
+------- Begin of linkChCapabilitiesTable
+--
+ combinedRadioCapabilitiesTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CombinedRadioCapabilitiesEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table with RadioCapabilities entries: there is an entry for each
+ radioSettingTable row.
+ In 1+1 HS and XPIC radio links, this table contains only values
+ supported by both radios belonging to the link.
+ In 1+1 FD radio link, managers have to know the allowable
+ duplex frequencies of each channel. As such, this table is declared
+ deprecated and replaced by combinedRadioCapabilitiesTable."
+ ::= {radioSystem 28}
+
+ combinedRadioCapabilitiesEntry OBJECT-TYPE
+ SYNTAX CombinedRadioCapabilitiesEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "combinedRadioCapabilities entry."
+ INDEX {radioSettingsIndex}
+ ::= {combinedRadioCapabilitiesTable 1}
+
+ CombinedRadioCapabilitiesEntry ::=
+ SEQUENCE {
+ combinedRadioCapabilitiesCapability RadioCapability,
+ combinedRadioCapabilitiesTxMinFrequency Integer32,
+ combinedRadioCapabilitiesTxMaxFrequency Integer32,
+ combinedRadioCapabilitiesStepFrequency Integer32,
+ combinedRadioCapabilitiesMinPtxNominalValue Integer32,
+ combinedRadioCapabilitiesMaxPtxNominalValue Integer32,
+ combinedRadioCapabilitiesExtendedMinPwr Integer32
+ }
+
+ combinedRadioCapabilitiesCapability OBJECT-TYPE
+ SYNTAX RadioCapability
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Bit map to describe the radio features."
+ ::= {combinedRadioCapabilitiesEntry 1}
+
+ combinedRadioCapabilitiesTxMinFrequency OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Minimum of available channel frequency in KHz."
+ ::= {combinedRadioCapabilitiesEntry 2}
+
+ combinedRadioCapabilitiesTxMaxFrequency OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Maximum of available channel frequency in KHz."
+ ::= {combinedRadioCapabilitiesEntry 3}
+
+ combinedRadioCapabilitiesStepFrequency OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Minimum frequency step in KHz."
+ ::= {combinedRadioCapabilitiesEntry 4}
+
+ combinedRadioCapabilitiesMinPtxNominalValue OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Minimum nominal Ptx in dBm."
+ ::= {combinedRadioCapabilitiesEntry 5}
+
+ combinedRadioCapabilitiesMaxPtxNominalValue OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Maximum nominal Ptx in dBm."
+ ::= {combinedRadioCapabilitiesEntry 6}
+
+ combinedRadioCapabilitiesExtendedMinPwr OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Minimum extended Ptx power for fade margin."
+ ::= {combinedRadioCapabilitiesEntry 7}
+--
+------- End of combinedRadioCapabilitiesTable
+
+------- Begin of combinedRadioFrequencyTable
+--
+ combinedRadioFrequencyTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CombinedRadioFreqEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Availables channels for selected channel spacing and modulation
+ In 1+1 HS and XPIC radio links, this table contains only values
+ supported by both radios."
+ ::= {radioSystem 29}
+
+ combinedRadioFreqTabEntry OBJECT-TYPE
+ SYNTAX CombinedRadioFreqEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "combinedRadioFreqTab record."
+ INDEX {radioSettingsIndex, combinedRadioFreqChannelId}
+ ::= {combinedRadioFrequencyTable 1}
+
+ CombinedRadioFreqEntry ::=
+ SEQUENCE {
+ combinedRadioFreqChannelId Integer32,
+ combinedRadioFreqChannelNum Integer32,
+ combinedRadioFreqValue Integer32
+ }
+
+ combinedRadioFreqChannelId OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index of the table"
+ ::= {combinedRadioFreqTabEntry 1}
+
+ combinedRadioFreqChannelNum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Available channel number."
+ ::= {combinedRadioFreqTabEntry 2}
+
+ combinedRadioFreqValue OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Frequency related to combinedRadioFreqChannelNum."
+ ::= {combinedRadioFreqTabEntry 3}
+--
+------- End of combinedRadioFrequencyTable
+
+------- Begin of combinedRadioDuplexFrequencyTable
+--
+ combinedRadioDuplexFrequencyTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CombinedRadioDuplexFreqEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table with available duplex frequencies. Duplex frequency is
+ the absolute value of difference between RX and TX frequency.
+ In 1+1 HS and XPIC radio links, this table contains only values
+ supported by both radios."
+ ::= {radioSystem 30}
+
+ combinedRadioDuplexFreqEntry OBJECT-TYPE
+ SYNTAX CombinedRadioDuplexFreqEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Duplex Frequency entry. There is an entry for each available
+ duplex frequency."
+ INDEX {radioSettingsIndex, combinedRadioDuplexFreqId}
+ ::= {combinedRadioDuplexFrequencyTable 1}
+
+ CombinedRadioDuplexFreqEntry ::=
+ SEQUENCE {
+ combinedRadioDuplexFreqId Integer32,
+ combinedRadioDuplexFreqValue Integer32
+ }
+
+ combinedRadioDuplexFreqId OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index of the table."
+ ::= {combinedRadioDuplexFreqEntry 1}
+
+ combinedRadioDuplexFreqValue OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Duplex frequency in KHz."
+ ::= {combinedRadioDuplexFreqEntry 2}
+--
+------- End of combinedRadioDuplexFrequencyTable
+
+------- Begin of combinedRadioPowerScalingTable
+--
+ combinedRadioPowerScalingTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CombinedRadioPowerScalingEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "List of modulation related to channel spacing.
+ In 1+1 HS and XPIC radio links, this table contains only values
+ supported by both radios."
+ ::= {radioSystem 31}
+
+ combinedRadioPowerScalingEntry OBJECT-TYPE
+ SYNTAX CombinedRadioPowerScalingEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "radioPowerScaling record."
+ INDEX {radioSettingsIndex, linkAcmProfileId}
+ ::= {combinedRadioPowerScalingTable 1}
+
+ CombinedRadioPowerScalingEntry ::=
+ SEQUENCE {
+ combinedRadioPowerScaling Integer32,
+ combinedRadioAtpcRxPowerScaling Integer32,
+ combinedRadioPowerRange Integer32
+ }
+
+ combinedRadioPowerScaling OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object contains the difference (in eighth of dB) between the
+ TX power at this profile modulation and the TX power at the
+ reference modulation. The power scaling value is achieved from the
+ table linkPtxProfileTable."
+ ::= {combinedRadioPowerScalingEntry 1}
+
+ combinedRadioAtpcRxPowerScaling OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object contains the difference (in eighth of dB) between the
+ ATPC RX level thresholds at this profile modulation and the ATPC
+ RX level thresholds at the upper modulation."
+ ::= {combinedRadioPowerScalingEntry 2}
+
+ combinedRadioPowerRange OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object contains (in dB) the current value of ATPC range."
+ ::= {combinedRadioPowerScalingEntry 3}
+--
+------- End of radioPowerScalingTable
+
+------- Begin of stm1BulkSettingsTable
+--
+ stm1BulkMappingTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Stm1BulkMappingEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table with entries containing stm-1 bulk transport parameters
+ for a particular link.
+ For each link are present as many rows as the STM-1 that the link
+ can carry in bulk mode.
+ "
+ ::= {radioSystem 32}
+
+ stm1BulkMappingEntry OBJECT-TYPE
+ SYNTAX Stm1BulkMappingEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An row in stm1BulkSettingsTable.
+ "
+ INDEX {linkIndex, stm1BulkPolIndex, stm1BulkChanIndex}
+ ::= {stm1BulkMappingTable 1}
+
+ Stm1BulkMappingEntry ::=
+ SEQUENCE {
+ stm1BulkPolIndex Integer32,
+ stm1BulkChanIndex Integer32,
+ stm1BulkChannel Stm1IndexOrZero
+ }
+
+ stm1BulkPolIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Polarization index.
+ "
+ ::= {stm1BulkMappingEntry 1}
+
+ stm1BulkChanIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "STM-1 channel index.
+ The range of this object is from 1 to N, where N is the number
+ of STM-1 that a link can carry in bulk mode.
+ "
+ ::= {stm1BulkMappingEntry 2}
+
+ stm1BulkChannel OBJECT-TYPE
+ SYNTAX Stm1IndexOrZero
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Index of the stm-1 in stm1Table.
+ The SNMP agent will accept only index of a STM-1 present in
+ stm1Table with stm1Structure set to opaque(4).
+ "
+ DEFVAL {0}
+ ::= {stm1BulkMappingEntry 3}
+
+--
+------- End of stm1BulkSettingsTable
+
+------- Begin of linkE1vsSTM1CapacityTable
+--
+
+ linkE1vsSTM1CapacityTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF LinkE1vsSTM1CapacityEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table with entries containing the E1 cpacity according to the
+ tributaries STM-1 configured to be carried in bulk mode.
+ "
+ ::= {radioSystem 33}
+
+ linkE1vsSTM1CapacityEntry OBJECT-TYPE
+ SYNTAX LinkE1vsSTM1CapacityEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An row in linkE1vsSTM1CapacityTable.
+ "
+ INDEX {linkIndex, linkAcmProfileId, linkE1vsSTM1CapacityStm1}
+ ::= {linkE1vsSTM1CapacityTable 1}
+
+ LinkE1vsSTM1CapacityEntry ::=
+ SEQUENCE {
+ linkE1vsSTM1CapacityStm1 Integer32,
+ linkE1vsSTM1CapacityE1 Integer32
+ }
+
+ linkE1vsSTM1CapacityStm1 OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Number of tributaries STM-1 configured to be transported in
+ bulk mode.
+ "
+ ::= {linkE1vsSTM1CapacityEntry 1 }
+
+ linkE1vsSTM1CapacityE1 OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of E1 that can be carried by this profile according to the
+ the tributaries STM-1 carried in bulk mode.
+ "
+ ::= {linkE1vsSTM1CapacityEntry 2}
+
+--
+------- End of linkE1vsSTM1CapacityTable
+
+------- Begin of linkTfcV2Table
+--
+ linkTfcV2Table OBJECT-TYPE
+ SYNTAX SEQUENCE OF LinkTfcV2Entry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Transmitter Fail Check feature. In 1+1 HS configuration, the
+ radio terminal that doesn't receive signals on both receivers,
+ requests the remote transmitter switch."
+ ::= {radioSystem 34}
+
+ linkTfcV2Entry OBJECT-TYPE
+ SYNTAX LinkTfcV2Entry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Radio link TFC entry."
+ INDEX {linkIndex, linkPolIndex}
+ ::= {linkTfcV2Table 1}
+
+ LinkTfcV2Entry ::=
+ SEQUENCE {
+ linkTfcV2Action INTEGER,
+ linkTfcV2Control INTEGER,
+ linkTfcV2WatchWindow INTEGER,
+ linkTfcV2AlarmThreshold INTEGER,
+ linkTfcV2Alarm AlarmStatus,
+ linkTfcV2RowStatus RowStatus
+ }
+
+ linkTfcV2Action OBJECT-TYPE
+ SYNTAX INTEGER {
+ notActive (0),
+ reset (1)
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "reset: to clear the forced switch generated by Trasmission Fail
+ Check algorithm (only if 1+1 configuration and ISO system)."
+ ::= {linkTfcV2Entry 1}
+
+ linkTfcV2Control OBJECT-TYPE
+ SYNTAX INTEGER {
+ disable (1),
+ enable (2)
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "It enables the Tx switch from remote equipment (only if 1+1
+ configuration and ISO system)."
+ DEFVAL {disable}
+ ::= {linkTfcV2Entry 2}
+
+ linkTfcV2WatchWindow OBJECT-TYPE
+ SYNTAX INTEGER (1..300)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Watch Window (in seconds) related to Trasmission Fail Check
+ algorithm (only if 1+1 configuration and ISO system)."
+ DEFVAL { 60 }
+ ::= {linkTfcV2Entry 3}
+
+ linkTfcV2AlarmThreshold OBJECT-TYPE
+ SYNTAX INTEGER (1..60)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Alarm Threshold (number of seconds with both remote RX in fail)
+ related to Trasmission Fail Check algorithm (only if 1+1
+ configuration and ISO system)."
+ DEFVAL { 10 }
+ ::= {linkTfcV2Entry 4}
+
+ linkTfcV2Alarm OBJECT-TYPE
+ SYNTAX AlarmStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Transmission switch alarm generated by Trasmission Fail Check
+ algorithm (only if 1+1 configuration and ISO system)."
+ ::= {linkTfcV2Entry 5}
+
+ linkTfcV2RowStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Status of this conceptual row in linkTfcV2Table."
+ ::= {linkTfcV2Entry 6}
+
+--
+------- End of linkTfcV2Table
+
+------- Begin of linkProV2Table
+--
+ linkProV2Table OBJECT-TYPE
+ SYNTAX SEQUENCE OF LinkProV2Entry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of protection link entries.
+ "
+ ::= {radioSystem 35}
+
+ linkProV2Entry OBJECT-TYPE
+ SYNTAX LinkProV2Entry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing management information applicable to a
+ protected link.
+ "
+ INDEX {linkIndex, linkPolIndex}
+ ::= {linkProV2Table 1}
+
+ LinkProV2Entry ::=
+ SEQUENCE {
+ linkProV2ProtectionTxChIdx Integer32,
+ linkProV2ProtectionRxChIdx Integer32,
+ linkProV2TxWtrTime INTEGER,
+ linkProV2RxWtrTime INTEGER,
+ linkProV2TxSwitchedChIdx Integer32,
+ linkProV2RxSwitchedChIdx Integer32,
+ linkProV2TxRevertive INTEGER,
+ linkProV2RxRevertive INTEGER,
+ linkProV2ExtraTraffic INTEGER,
+ linkProV2RowStatus RowStatus
+ }
+
+ linkProV2ProtectionTxChIdx OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object identifies the tx protection channel
+ of a protected link. This object is not applicable
+ in case of not-revertive protection. For N+1 links
+ a value different from zero must be set.
+ "
+ DEFVAL {0}
+ ::= {linkProV2Entry 1}
+
+ linkProV2ProtectionRxChIdx OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object identifies the rx protection channel
+ of a protected link. This object is not applicable
+ in case of not-revertive protection. For N+1 links
+ a value different from zero must be set.
+ "
+ DEFVAL {0}
+ ::= {linkProV2Entry 2}
+
+ linkProV2TxWtrTime OBJECT-TYPE
+ SYNTAX INTEGER (0..12)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "It defines the Wait Time (in minutes) to Restore in transmission
+ when revertive protection is enabled. Zero value means no switch.
+ If switch is not supported or protection is not revertive,
+ a value different from zero cannot be set.
+ "
+ DEFVAL {0}
+ ::= {linkProV2Entry 3}
+
+ linkProV2RxWtrTime OBJECT-TYPE
+ SYNTAX INTEGER (0..12)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "It defines the Wait Time (in minutes) to Restore in reception when
+ revertive protection is enabled. Zero value means no switch.
+ If switch is not supported or protection is not revertive,
+ a value different from zero cannot be set.
+ "
+ DEFVAL {0}
+ ::= {linkProV2Entry 4}
+
+ linkProV2TxSwitchedChIdx OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reports the index of tx channel switched to protection.
+ This object is applicable only for N+1 protection schema.
+ "
+ DEFVAL {0}
+ ::= {linkProV2Entry 5}
+
+ linkProV2RxSwitchedChIdx OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reports the index of rx channel switched to protection.
+ This object is applicable only for N+1 protection schema.
+ "
+ DEFVAL {0}
+ ::= {linkProV2Entry 6}
+
+ linkProV2TxRevertive OBJECT-TYPE
+ SYNTAX INTEGER {
+ disable (1),
+ enable (2)
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "It defines if tx protection is revertive or not revertive.
+ In case of N+1 protection, protection is always revertive.
+ "
+ DEFVAL {disable}
+ ::= {linkProV2Entry 7}
+
+ linkProV2RxRevertive OBJECT-TYPE
+ SYNTAX INTEGER {
+ disable (1),
+ enable (2)
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "It defines if rx protection is revertive or not revertive.
+ In case of N+1 protection, protection is always revertive.
+ "
+ DEFVAL {disable}
+ ::= {linkProV2Entry 8}
+
+ linkProV2ExtraTraffic OBJECT-TYPE
+ SYNTAX INTEGER {
+ disable (1),
+ enable (2)
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object enables or disables the transfer of extra traffic
+ on the protection channel in a N+1 link. This object must be
+ set to disabled in case of architectures different for N+1.
+ "
+ DEFVAL {disable}
+ ::= {linkProV2Entry 9}
+
+ linkProV2RowStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Status of this conceptual row in linkProV2Table.
+ "
+ ::= {linkProV2Entry 10}
+
+--
+------- End of linkProV2Table
+
+------- Begin of linkProMaintV2Table
+--
+ linkProMaintV2Table OBJECT-TYPE
+ SYNTAX SEQUENCE OF LinkProMaintV2Entry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of maintenance commands for protected links.
+ A row in this table is added on creation of a row
+ in linkProV2Table.
+ "
+ ::= {radioSystem 36}
+
+ linkProMaintV2Entry OBJECT-TYPE
+ SYNTAX LinkProMaintV2Entry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing maintenance commands applicable to a
+ protected link.
+ "
+ INDEX {linkIndex, linkPolIndex}
+ ::= {linkProMaintV2Table 1}
+
+ LinkProMaintV2Entry ::=
+ SEQUENCE {
+ linkProMaintV2TxLockout INTEGER,
+ linkProMaintV2RxLockout INTEGER,
+ linkProMaintV2TxForced Integer32,
+ linkProMaintV2RxForced Integer32,
+ linkProMaintV2TxWtrReset INTEGER,
+ linkProMaintV2RxWtrReset INTEGER
+ }
+
+ linkProMaintV2TxLockout OBJECT-TYPE
+ SYNTAX INTEGER {
+ disable (1),
+ enable (2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Command to enable/disable tx lockout. This object
+ is applicable only in case of N+1 protections.
+ "
+ DEFVAL {disable}
+ ::= {linkProMaintV2Entry 1}
+
+ linkProMaintV2RxLockout OBJECT-TYPE
+ SYNTAX INTEGER {
+ disable (1),
+ enable (2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Command to enable/disable rx lockout. This object
+ is applicable only in case of N+1 protections.
+ "
+ DEFVAL {disable}
+ ::= {linkProMaintV2Entry 2}
+
+ linkProMaintV2TxForced OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Command to force switch to a given
+ transmission channel. Zero value means no
+ switch.
+ "
+ DEFVAL {0}
+ ::= {linkProMaintV2Entry 3}
+
+ linkProMaintV2RxForced OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Command to force switch to a given
+ receiving channel. Zero value means no
+ switch.
+ "
+ DEFVAL {0}
+ ::= {linkProMaintV2Entry 4}
+
+ linkProMaintV2TxWtrReset OBJECT-TYPE
+ SYNTAX INTEGER {
+ notActive (1),
+ on (2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Clear wait time to restore making the revertive
+ path immediately available.
+ "
+ DEFVAL {notActive}
+ ::= {linkProMaintV2Entry 5}
+
+ linkProMaintV2RxWtrReset OBJECT-TYPE
+ SYNTAX INTEGER {
+ notActive (1),
+ on (2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Clear wait time to restore making the revertive
+ path immediately available.
+ "
+ DEFVAL {notActive}
+ ::= {linkProMaintV2Entry 6}
+
+--
+------- End of linkProMaintV2Table
+
+------- Begin of sspTable
+--
+ sspTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SspEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of operative and administrative set of parameters.
+ This table holds three row for every link (and its polarizations)
+ configured in the NE:
+ 1) administative parameters of local NE
+ 2) operative parameters of local NE
+ 3) administative parameters of remote NE
+ "
+ ::= {radioSystem 37}
+
+ sspEntry OBJECT-TYPE
+ SYNTAX SspEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing SSP relevant parameters.
+ "
+ INDEX {linkIndex, linkPolIndex, sspParameterType}
+ ::= {sspTable 1}
+
+ SspEntry ::=
+ SEQUENCE {
+ sspParameterType INTEGER,
+ sspLinkBandwidth INTEGER,
+ sspLinkModulation INTEGER,
+ sspLinkAcmEngineEnable INTEGER,
+ sspLinkTxUpperProfile INTEGER,
+ sspLinkTxLowerProfile INTEGER,
+ sspLinkSynchSetupProtocolEnable INTEGER,
+ sspLinkProfilesSetSelection INTEGER,
+ sspTdmE1Channel Integer32,
+ sspTdmStm1Channel Integer32
+ }
+
+ sspParameterType OBJECT-TYPE
+ SYNTAX INTEGER {
+ localAdminStatus (1),
+ localOperStatus (2),
+ remoteAdminStatus (3)
+ }
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This object identifies what parameters are for.
+ "
+ ::= {sspEntry 1}
+
+ sspLinkBandwidth OBJECT-TYPE
+ SYNTAX INTEGER {
+ sspBw3p5Mhz (0),
+ sspBw7MHz (1),
+ sspBw14MHz (2),
+ sspBw28MHz (3),
+ sspBw56MHz (4),
+ sspBw10MHz (5),
+ sspBw20MHz (6),
+ sspBw30MHz (7),
+ sspBw40MHz (8),
+ sspBw50MHz (9),
+ sspBw112Mhz (10),
+ sspBw250Mhz (11),
+ sspBw500Mhz (12),
+ sspBw750Mhz (13),
+ sspBw1Ghz (14),
+ sspBw60MHz (15),
+ sspBw80MHz (16)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Link Bandwidth (channel spacing).
+ "
+ ::= {sspEntry 2}
+
+ sspLinkModulation OBJECT-TYPE
+ SYNTAX INTEGER{
+ sspModBPSK (1),
+ sspMod4QAM (2),
+ sspMod8PSK (3),
+ sspMod16QAM (4),
+ sspMod32QAM (5),
+ sspMod64QAM (6),
+ sspMod128QAM (7),
+ sspMod256QAM (8),
+ sspMod512QAM (9),
+ sspMod1024QAM (10),
+ sspMod2048QAM (11),
+ sspMod4096QAM (12)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Link reference modulation.
+ "
+ ::= {sspEntry 3}
+
+ sspLinkAcmEngineEnable OBJECT-TYPE
+ SYNTAX INTEGER {
+ disable (1),
+ enable (2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object is used to enable/disable the ACM engine.
+ "
+ DEFVAL { disable }
+ ::= {sspEntry 4}
+
+ sspLinkTxUpperProfile OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The object (and linkTxLowerProfile object) is used to
+ restrict the TX profile range when ACM is enabled.
+ "
+ ::= {sspEntry 5}
+
+ sspLinkTxLowerProfile OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The object (and linkTxUpperProfile object) is used to
+ restrict the TX profile range when ACM is enabled.
+ "
+ ::= {sspEntry 6}
+
+ sspLinkSynchSetupProtocolEnable OBJECT-TYPE
+ SYNTAX INTEGER {
+ disable (1),
+ enable (2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Synchronization Setup Protocol (SSP) control.
+ "
+ ::= {sspEntry 7}
+
+ sspLinkProfilesSetSelection OBJECT-TYPE
+ SYNTAX INTEGER {
+ highThroughput (1),
+ highGain (2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Selection of the working profile set between high gain
+ (max robustness) profile set and high throughput (max
+ capacity) profile set. The set of profiles high gain
+ features a greater robustness against to the set of
+ profiles high throughput.
+ For radio systems that do not have more sets of profiles,
+ this object becomes read only and its reading shows the
+ only one set of profiles supported.
+ "
+ ::= {sspEntry 8}
+
+ sspTdmE1Channel OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of E1 channels. This object is used to define the capacity
+ of E1 tributaries assigned to a given radio link. The capacity is
+ changed in steps of E1 (2Mbit/s).
+ "
+ ::= {sspEntry 9}
+
+ sspTdmStm1Channel OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of STM-1 channels transported in bulk mode.
+ "
+ ::= {sspEntry 10}
+
+--
+------- End of sspTable
+
+------- Begin of radioLoopCapabilityTable
+--
+ radioLoopCapabilityTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF RadioLoopCapabilityEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table shows which group a radio loop belongs to.
+ Radios with the same group number (identifier) close loop
+ simultaneously.
+ "
+ ::= {radioSystem 38}
+
+ radioLoopCapabilityEntry OBJECT-TYPE
+ SYNTAX RadioLoopCapabilityEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing a group identifier for each radio loop type.
+ "
+ INDEX {radioIndex}
+ ::= {radioLoopCapabilityTable 1}
+
+ RadioLoopCapabilityEntry ::=
+ SEQUENCE {
+ radioLoopRfGroup Integer32,
+ radioLoopIqGroup Integer32,
+ radioLoopBaseBandGroup Integer32
+ }
+
+ radioLoopRfGroup OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The group to which the radio RF loop belong to.
+ "
+ ::= {radioLoopCapabilityEntry 1}
+
+
+ radioLoopIqGroup OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The group to which the radio IQ loop belong to.
+ "
+ ::= {radioLoopCapabilityEntry 2}
+
+ radioLoopBaseBandGroup OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The group to which the radio base loop belong to.
+ "
+ ::= {radioLoopCapabilityEntry 3}
+
+--
+------- End of radioLoopCapabilityTable
+
+------- Begin of radioRxThresholdTable
+--
+ radioRxBerThresholdTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF RadioRxBerThresholdEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table shows the nominal and measured values of RX power
+ at a bit error rate (BER) equal to 10e-6.
+ "
+ ::= {radioSystem 39}
+
+ radioRxBerThresholdEntry OBJECT-TYPE
+ SYNTAX RadioRxBerThresholdEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing the RX power thresholds.
+ "
+ INDEX {radioIndex}
+ ::= {radioRxBerThresholdTable 1}
+
+ RadioRxBerThresholdEntry ::=
+ SEQUENCE {
+ radioRxBerThresholdStatus INTEGER,
+ radioNominalRxBerThreshold Integer32,
+ radioMeasuredRxBerThreshold Integer32
+ }
+
+ radioRxBerThresholdStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ nonValid (1),
+ valid(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object shows whether the following objects are significant.
+ "
+ ::= {radioRxBerThresholdEntry 1}
+
+ radioNominalRxBerThreshold OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The nominal value of RX power @ BER equal to 10e-6
+ "
+ ::= {radioRxBerThresholdEntry 2}
+
+ radioMeasuredRxBerThreshold OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The measured value of RX power @ BER equal to 10e-6.
+ "
+ ::= {radioRxBerThresholdEntry 3}
+
+--
+------- End of radioRxThresholdTable
+
+
+ radioRemDemodulatorFailAlarmSeverityCode OBJECT-TYPE
+ SYNTAX AlarmSeverityCode
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Defines the severity associated to the radioRemDemodulatorFailAlarm
+ and enables/disables the trap generation on status change event."
+ DEFVAL {majorTrapEnable}
+ ::= {radioSystem 50}
+
+ radioRxActiveStatusTrapNotification OBJECT-TYPE
+ SYNTAX INTEGER {
+ trapDisable (1),
+ trapEnable (2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable/disables (statusTrapEnable or statusTrapDisable) the trap
+ generation on status change event for radioRxActivestatus"
+ DEFVAL{ trapEnable }
+ ::= {radioSystem 51}
+
+ radioTxActiveStatusTrapNotification OBJECT-TYPE
+ SYNTAX INTEGER {
+ trapDisable (1),
+ trapEnable (2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Define the severity associated to the radioTxActivestatus and
+ enable/disable the trap generation on status change event."
+ DEFVAL{ trapEnable }
+ ::= {radioSystem 52}
+
+ radioCableOpenAlarmSeverityCode OBJECT-TYPE
+ SYNTAX AlarmSeverityCode
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Defines the severity associated to the radioCableOpen
+ and enables/disables the trap generation on status change event."
+ DEFVAL {majorTrapEnable}
+ ::= {radioSystem 53}
+
+ radioCableShortAlarmSeverityCode OBJECT-TYPE
+ SYNTAX AlarmSeverityCode
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Defines the severity associated to the radioCableShort
+ and enables/disables the trap generation on status change event."
+ DEFVAL {majorTrapEnable}
+ ::= {radioSystem 54}
+
+ radioInvalidFrequencyAlarmSeverityCode OBJECT-TYPE
+ SYNTAX AlarmSeverityCode
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Defines the severity associated to the radioInvalidFrequencyAlarm
+ and enables/disables the trap generation on status change event."
+ DEFVAL {majorTrapEnable}
+ ::= {radioSystem 55}
+
+ radioBaseBandRxAlarmSeverityCode OBJECT-TYPE
+ SYNTAX AlarmSeverityCode
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Defines the severity associated to the radioBaseBandRxAlarm
+ and enables/disables the trap generation on status change event."
+ DEFVAL {majorTrapEnable}
+ ::= {radioSystem 56}
+
+ radioModulatorFailAlarmSeverityCode OBJECT-TYPE
+ SYNTAX AlarmSeverityCode
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Defines the severity associated to the radioModulatorFailAlarm
+ and enables/disables the trap generation on status change event."
+ DEFVAL {majorTrapEnable}
+ ::= {radioSystem 57}
+
+ radioDemodulatorFailAlarmSeverityCode OBJECT-TYPE
+ SYNTAX AlarmSeverityCode
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Defines the severity associated to the radioDemodulatorFailAlarm
+ and enables/disables the trap generation on status change event."
+ DEFVAL {majorTrapEnable}
+ ::= {radioSystem 58}
+
+ radioRxPowerLowAlarmSeverityCode OBJECT-TYPE
+ SYNTAX AlarmSeverityCode
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Defines the severity associated to the radioRxPowerLowAlarm
+ and enables/disables the trap generation on status change event."
+ DEFVAL {majorTrapEnable}
+ ::= {radioSystem 59}
+
+ radioTxPowerLowAlarmSeverityCode OBJECT-TYPE
+ SYNTAX AlarmSeverityCode
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Defines the severity associated to the radioTxPowerLowAlarm
+ and enables/disables the trap generation on status change event."
+ DEFVAL {majorTrapEnable}
+ ::= {radioSystem 60}
+
+ radioVcoFailAlarmSeverityCode OBJECT-TYPE
+ SYNTAX AlarmSeverityCode
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Defines the severity associated to the radioVcoFailAlarm
+ and enables/disables the trap generation on status change event."
+ DEFVAL {majorTrapEnable}
+ ::= {radioSystem 61}
+
+ radioRxIFAgcAlarmSeverityCode OBJECT-TYPE
+ SYNTAX AlarmSeverityCode
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Defines the severity associated to the radioRxIFAgcAlarm
+ and enables/disables the trap generation on status change event."
+ DEFVAL {majorTrapEnable}
+ ::= {radioSystem 62}
+
+ radioTxIFAgcAlarmSeverityCode OBJECT-TYPE
+ SYNTAX AlarmSeverityCode
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Defines the severity associated to the radioTxIFAgcAlarm
+ and enables/disables the trap generation on status change event."
+ DEFVAL {majorTrapEnable}
+ ::= {radioSystem 63}
+
+ radioIduOduCommunicationAlarmSeverityCode OBJECT-TYPE
+ SYNTAX AlarmSeverityCode
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Define the severity associated to the radioIduOduCommunicationAlarm
+ and enable/disable the trap generation on status change event."
+ DEFVAL {majorTrapEnable}
+ ::= {radioSystem 64}
+
+ radioOduIduCommunicationAlarmSeverityCode OBJECT-TYPE
+ SYNTAX AlarmSeverityCode
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Define the severity associated to the radioOduIduCommunicationAlarm
+ and enable/disable the trap generation on status change event."
+ DEFVAL {warningTrapEnable}
+ ::= {radioSystem 65}
+
+ radioLocalOduAlarmSynthesisSeverityCode OBJECT-TYPE
+ SYNTAX AlarmSeverityCode
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Define the severity associated to the radioLocalOduAlarmSynthesis
+ and enable/disable the trap generation on status change event."
+ DEFVAL {statusTrapDisable}
+ ::= {radioSystem 66}
+
+ radioRemoteOduAlarmSynthesisSeverityCode OBJECT-TYPE
+ SYNTAX AlarmSeverityCode
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Define the severity associated to the radioRemoteOduAlarmSynthesis
+ and enable/disable the trap generation on status change event."
+ DEFVAL {statusTrapDisable}
+ ::= {radioSystem 67}
+
+ radioConfigMismatchAlarmSeverityCode OBJECT-TYPE
+ SYNTAX AlarmSeverityCode
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Defines the severity associated to the radioConfigMismatchAlarm
+ and enables/disables the trap generation on status change event."
+ DEFVAL {majorTrapEnable}
+ ::= {radioSystem 68}
+
+ radioPrxHysteresisValue OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Defines the delta value associated to the radioPrx before
+ having a new trap generation (radioPtxChange TRAP).
+ The zero value is not allowed."
+ DEFVAL {3}
+ ::= {radioSystem 69}
+
+ radioPtxHysteresisValue OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Defines the delta value associated to the radioPtx before
+ having a new trap generation (radioPtxChange TRAP).
+ The zero value is not allowed."
+ DEFVAL {3}
+ ::= {radioSystem 70}
+
+ radioPrxHysteresisValueTrapNotification OBJECT-TYPE
+ SYNTAX INTEGER {
+ trapDisable (1),
+ trapEnable (2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enables/disables the Rx change trap generation on status change
+ event."
+ DEFVAL {trapEnable}
+ ::= {radioSystem 71}
+
+ radioPtxHysteresisValueTrapNotification OBJECT-TYPE
+ SYNTAX INTEGER {
+ trapDisable (1),
+ trapEnable (2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enables/disables the Tx change trap generation on status change
+ event."
+ DEFVAL {trapEnable}
+ ::= {radioSystem 72}
+
+ radioRxQualityLowAlarmSeverityCode OBJECT-TYPE
+ SYNTAX AlarmSeverityCode
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Define the severity associated to the radioRxQualityLowAlarm
+ and enable/disable the trap generation on status change event."
+ DEFVAL {majorTrapEnable}
+ ::= {radioSystem 73}
+
+ radioRxQualityWarningAlarmSeverityCode OBJECT-TYPE
+ SYNTAX AlarmSeverityCode
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Define the severity associated to the radioRxQualityWarningAlarm
+ and enable/disable the trap generation on status change event."
+ DEFVAL {majorTrapEnable}
+ ::= {radioSystem 74}
+
+ linkReducedCapacityAlarmSeverityCode OBJECT-TYPE
+ SYNTAX AlarmSeverityCode
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Define the severity associated to the linkReducedCapacityAlarm
+ and enable/disable the trap generation on status change event."
+ DEFVAL {warningTrapEnable}
+ ::= {radioSystem 75}
+
+ linkLinkTelemetryFailAlarmSeverityCode OBJECT-TYPE
+ SYNTAX AlarmSeverityCode
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Define the severity associated to the linkLinkTelemetryFailAlarm
+ and enable/disable the trap generation on status change event."
+ DEFVAL {majorTrapEnable}
+ ::= {radioSystem 76}
+
+ linkIdMismatchAlarmSeverityCode OBJECT-TYPE
+ SYNTAX AlarmSeverityCode
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Define the severity associated to the linkIdMismatchAlarm
+ and enable/disable the trap generation on status change event."
+ DEFVAL {majorTrapEnable}
+ ::= {radioSystem 77}
+
+ linkRadioEocAlarmSeverityCode OBJECT-TYPE
+ SYNTAX AlarmSeverityCode
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Define the severity associated to the linkRadioEocAlarm
+ and enable/disable the trap generation on status change event."
+ DEFVAL {majorTrapEnable}
+ ::= {radioSystem 78}
+
+ linkSetupMismatchAlarmSeverityCode OBJECT-TYPE
+ SYNTAX AlarmSeverityCode
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Define the severity associated to the linkSetupMismatchAlarm
+ and enable/disable the trap generation on status change event."
+ DEFVAL {warningTrapEnable}
+ ::= {radioSystem 79}
+
+ linkRescueSetupAlarmSeverityCode OBJECT-TYPE
+ SYNTAX AlarmSeverityCode
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Define the severity associated to the linkRescueSetupAlarm
+ and enable/disable the trap generation on status change event."
+ DEFVAL {criticalTrapEnable}
+ ::= {radioSystem 80}
+
+ linkXpicProcedureBlockAlarmSeverityCode OBJECT-TYPE
+ SYNTAX AlarmSeverityCode
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Define the severity associated to the linkXpicProcedureBlockAlarm
+ and enable/disable the trap generation on status change event."
+ DEFVAL {majorTrapEnable}
+ ::= {radioSystem 81}
+
+ linkXpicRemTxOffAlarmAlarmSeverityCode OBJECT-TYPE
+ SYNTAX AlarmSeverityCode
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Define the severity associated to the linkXpicRemTxOffAlarm
+ and enable/disable the trap generation on status change event."
+ DEFVAL {majorTrapEnable}
+ ::= {radioSystem 82}
+
+ linkLocalIduAlarmSynthesis OBJECT-TYPE
+ SYNTAX AlarmStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Synthesis of the local IDU alarms"
+ ::= {radioSystem 83}
+
+ linkLocalIduAlarmSynthesisSeverityCode OBJECT-TYPE
+ SYNTAX AlarmSeverityCode
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Define the severity associated to the linkLocalIduAlarmSynthesis
+ and enable/disable the trap generation on status change event."
+ DEFVAL{ statusTrapDisable }
+ ::= {radioSystem 84}
+
+ linkRemoteIduAlarmSynthesisSeverityCode OBJECT-TYPE
+ SYNTAX AlarmSeverityCode
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Define the severity associated to the linkLocalIduAlarmSynthesis
+ and enable/disable the trap generation on status change event."
+ DEFVAL{ statusTrapDisable }
+ ::= {radioSystem 85}
+
+ linkTfcAlarmSeverityCode OBJECT-TYPE
+ SYNTAX AlarmSeverityCode
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Define the severity associated to the linkTfcV2Alarm (linkTfcAlarm)
+ and enable/disable the trap generation on status change event."
+ DEFVAL { minorTrapEnable }
+ ::= {radioSystem 86}
+
+ linkBerSyncLossAlarmSeverityCode OBJECT-TYPE
+ SYNTAX AlarmSeverityCode
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Define the severity associated to the linkBerSyncLossAlarm
+ and enable/disable the trap generation on status change event."
+ DEFVAL {majorTrapEnable}
+ ::= {radioSystem 87}
+
+ linkNotMatchingRadiosAlarmSeverityCode OBJECT-TYPE
+ SYNTAX AlarmSeverityCode
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Define the severity associated to the linkNotMatchingRadiosAlarm
+ and enable/disable the trap generation on status change event."
+ DEFVAL {majorTrapEnable}
+ ::= {radioSystem 88}
+
+ channelSpacingSelection OBJECT-TYPE
+ SYNTAX BITS {
+ etsi (0),
+ fcc (1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "his object selects which channel spacings the radio link has to
+ support:
+ - etsi: Compliant with European Telecommunication Standards
+ Institute
+ - fcc: Compliant with Federal Communications Commission
+ "
+ DEFVAL { { etsi, fcc } }
+ ::= {radioSystem 89}
+
+ fadeMarginMeasure OBJECT-TYPE
+ SYNTAX INTEGER {
+ disable (1),
+ enable (2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Set by manager to start/stop fade margin measure.
+ This item is linked to a manual operation (ManOpRecord) instance."
+ DEFVAL { disable }
+ ::= {radioSystem 90}
+
+ linkConfigurationInProgressTrapNotification OBJECT-TYPE
+ SYNTAX INTEGER {
+ trapDisable (1),
+ trapEnable (2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable/disables (statusTrapEnable or statusTrapDisable) the trap
+ generation on status change event for linkConfigurationInProgress"
+ DEFVAL{ trapEnable }
+ ::= {radioSystem 91}
+
+-----------------------
+-- This MIB module generates the following TRAPs:
+-----------------------
+ radioPrxChange NOTIFICATION-TYPE
+ OBJECTS {equipIpSnmpAgentAddress, radioIndex, radioSettingsLabel, radioPrx}
+ STATUS current
+ DESCRIPTION
+ "This event is generated when radioPrx is changed, in
+ modulus, more than radioPtxHysteresisValue from last TRAP.
+ The data passed with the event are:
+ 1) equipIpSnmpAgentAddress - agent IP address
+ 2) radioIndex - branch index
+ 3) radioName - user assinged name
+ 4) radioPrx - PRX value"
+ ::= { alarmTrap 8001 }
+
+ radioPtxChange NOTIFICATION-TYPE
+ OBJECTS {equipIpSnmpAgentAddress, radioIndex, radioSettingsLabel, radioPtx}
+ STATUS current
+ DESCRIPTION
+ "This event is generated when radioPtx is changed, in
+ modulus, more than radioPtxHysteresisValue from last TRAP.
+ The data passed with the event are:
+ 1) equipIpSnmpAgentAddress - agent IP address
+ 2) radioIndex - branch index
+ 3) radioName - user assigned name
+ 4) radioPtx - PTX value"
+ ::= { alarmTrap 8002 }
+
+------ End group -----------------------------------------------------------------
+
+---------------------------------- End -------------------------------------
+
+
+END
+