diff options
| author | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
|---|---|---|
| committer | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
| commit | 98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch) | |
| tree | 9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/smartoptics/MSERIES-TC | |
| download | mibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.tar.gz mibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.zip | |
Diffstat (limited to 'MIBS/smartoptics/MSERIES-TC')
| -rw-r--r-- | MIBS/smartoptics/MSERIES-TC | 237 |
1 files changed, 237 insertions, 0 deletions
diff --git a/MIBS/smartoptics/MSERIES-TC b/MIBS/smartoptics/MSERIES-TC new file mode 100644 index 0000000..ae6e152 --- /dev/null +++ b/MIBS/smartoptics/MSERIES-TC @@ -0,0 +1,237 @@ + -- SmartOptics Enterprise Specific TC MIB. +-- +-- Copyright (c) 2011, SmartOptics +-- All rights reserved +-- + +MSERIES-TC DEFINITIONS ::= BEGIN + +IMPORTS + MODULE-IDENTITY + FROM SNMPv2-SMI + TEXTUAL-CONVENTION + FROM SNMPv2-TC + mseries + FROM MSERIES-MIB; + + +smartTcMIB MODULE-IDENTITY + LAST-UPDATED "201402121327Z" + ORGANIZATION "SmartOptics" + CONTACT-INFO "http://www.smartoptics.com" + DESCRIPTION + "This is the enterprise specific TC MIB for SmartOptics M-Series" + REVISION "201402121327Z" + DESCRIPTION + "Added PortStatus and PortMode." + + REVISION "201310151341Z" + DESCRIPTION + "Descriptions updated." + REVISION "201112050000Z" + DESCRIPTION + "Initial revision." + + ::= { mseries 5 } + +-- +-- definitions of the textual convetions +-- + +AlarmPerceivedSeverity ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "Alarm severity as defined in ITU-T X.733." + SYNTAX INTEGER { + cleared (1), + indeterminate (2), + critical (3), + major (4), + minor (5), + warning (6) + } + +AlarmNotificationType ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "Type of alarm as defined in ITU-T X.733." + SYNTAX INTEGER { + undefined (0), + other (1), + communicationsAlarm (2), + qualityOfServiceAlarm (3), + processingErrorAlarm (4), + equipmentAlarm (5), + environmental (6), + integrityViolation (7), + operationalViolation (8), + physicalViolation(9), + securityServiceOrMechanismViloation (10), + timeDomainViolation (11) + } + +AlarmProbableCause ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "Alarm probable cause as defined in ITU-T X.733." + SYNTAX INTEGER { + undefined (0), + adapterError (1), -- Equipment + applicationSubsystemFailure (2), -- Processing + bandwidthReduced (3), -- Quality of service + callEstablishmentError (4), -- Communications + communicationsProtocolError (5), -- Communications + communicationsSubsystemFailure (6), -- Communications + configurationOrCustomizationError (7), -- Processing + congestion (8), -- Quality of service + corruptData (9), -- Processing + cpuCyclesLimitExceeded (10), -- Processing + dTEdCEInterfaceError (11), -- Communications + datasetOrModemError (12), -- Equipment + degradedSignal (13), -- Communications + enclosureDoorOpen (14), -- Environmental + equipmentMalfunction (15), -- Equipment + excessiveVibration (16), -- Environmental + fileError (17), -- Processing + fireDetected (18), -- Environmental + floodDetected (19), -- Environmental + framingError (20), -- Communications + heatingOrVentilationOrCoolingSystemProblem (21), -- Environmental + humidityUnacceptable (22), -- Environmental + inputDeviceError (23), -- Equipment + inputOutputDeviceError (24), -- Equipment + lANError (25), -- Communications + leakDetected (26), -- Environmental + localNodeTransmissionError (27), -- Communications + lossOfFrame (28), -- Communications + lossOfSignal (29), -- Communications + materialSupplyExhausted (30), -- Environmental + multiplexerProblem (31), -- Equipment + outOfMemory (32), -- Processing + outputDeviceError (33), -- Equipment + performanceDegraded (34), -- Quality of service + powerProblem (35), -- Equipment + pressureUnacceptable (36), -- Environmental + processorProblem (37), -- Equipment + pumpFailure (38), -- Environmental + queueSizeExceeded (39), -- Quality of service + receiveFailure (40), -- Equipment + receiverFailure (41), -- Equipment + remoteNodeTransmissionError (42), -- Communications + resourceAtOrNearingCapacity (43), -- Quality of service + responseTimeExcessive (44), -- Quality of service + retransmissionRateExcessive (45), -- Quality of service + softwareProgramError (46), -- Processing + softwareError (47), -- Processing + softwareProgramAbnormallyTerminated (48), -- Processing + storageCapacityProblem (49), -- Processing + temperatureUnacceptable (50), -- Environmental + thresholdCrossed (51), -- Quality of service + timingProblem (52), -- Equipment + toxicLeakDetected (53), -- Environmental + transmitFailure (54), -- Equipment + transmitterFailure (55), -- Equipment + underlyingResourceUnavailable (56), -- Processing + versionMismatch (57) } -- Processing + + +UnitType ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "The unit type in the M-Series. + + nmb - Network Management Board. The controlling + board of the M-Series. + + psu1 - The Power Supply in slot 1 of the M-Series. + + psu2 - The Power Supply in slot 2 of the M-Series. + + fan - The Fan of the M-Series. + + system - The chassis. + + slaveNmb - Network Management Board of the Cascading system. + + slavePsu1 - The Power Supply in slot 1 of the Cascading M-Series. + + slavePsu2 - The Power Supply in slot 2 of the Cascading M-Series. + + slaveFan - The Fan of the Cascading M-Series." + SYNTAX INTEGER { + nmb (1), + psu1 (2), + psu2 (3), + fan (4), + system (5), + slaveNmb (6), + slavePsu1 (7), + slavePsu2 (8), + slaveFan (9) + } + +PortType ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "Port direction. + + rx - The port direction is receiving(Rx). + + tx - The port direction is transmitting(Tx). + + biDi - The port direction is both transmitting and receiving." + SYNTAX INTEGER { + rx (1), + tx (2), + biDi (3) + } + +PortStatus ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "The operational state for a port. + + idle - The port is not activated + + down - The port traffic is lost. + + up - There is traffic on the port. + + high - The port got to high power. + + low - The port got to low power. + + eyeSafety - The Line Tx port is in Eye Safety Mode. + This means that either the connector on the + Line Tx port is not inserted or that you have + too strong reflection from the line fiber. + + cd - Channel detected. + + ncd - No channel detected." + SYNTAX INTEGER { + idle (1), + down (2), + up (3), + high (4), + low (5), + eyeSafety (6), + cd (7), + ncd (8) } + +PortMode ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "Port Mode. + + normal - The port is active. Alarms are not suppressed. + + service - the port is in Service Mode. Alarms are + beeing suppressed. When service is ready the + Port Mode should be set back to normal." + SYNTAX INTEGER { + normal (1), + service (2) + } + +END |