summaryrefslogtreecommitdiff
path: root/MIBS/telco-systems/binox/PRVT-LMM-MIB
diff options
context:
space:
mode:
authorDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
committerDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
commit98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch)
tree9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/telco-systems/binox/PRVT-LMM-MIB
downloadmibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.tar.gz
mibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.zip
Initial commitHEADmain
Diffstat (limited to 'MIBS/telco-systems/binox/PRVT-LMM-MIB')
-rw-r--r--MIBS/telco-systems/binox/PRVT-LMM-MIB426
1 files changed, 426 insertions, 0 deletions
diff --git a/MIBS/telco-systems/binox/PRVT-LMM-MIB b/MIBS/telco-systems/binox/PRVT-LMM-MIB
new file mode 100644
index 0000000..dfabf0d
--- /dev/null
+++ b/MIBS/telco-systems/binox/PRVT-LMM-MIB
@@ -0,0 +1,426 @@
+-- *********************************************************************
+-- **
+-- ** BATM Advanced Communications.
+-- **
+-- *********************************************************************
+-- ** Filename: PRVT-LMM-MIB.mib
+-- ** Project: T-Metro Switches.
+-- ** Purpose: Private MIB
+-- *********************************************************************
+-- (c) Copyright, 2009, BATM Advanced Communications. All rights reserved.
+-- WARNING:
+--
+-- BY UTILIZING THIS FILE, YOU AGREE TO THE FOLLOWING:
+--
+-- This file is the property of BATM Advanced Communications and contains
+-- proprietary and confidential information. This file is made
+-- available to authorized BATM customers on the express
+-- condition that neither it, nor any of the information contained
+-- therein, shall be disclosed to third parties or be used for any
+-- purpose other than to replace, modify or upgrade firmware and/or
+-- software components of BATM manufactured equipment within the
+-- authorized customer's network, and that such transfer be
+-- completed in accordance with the instructions provided by
+-- BATM. Any other use is strictly prohibited.
+--
+-- EXCEPT AS RESTRICTED BY LAW, OR AS PROVIDED IN BATM'S LIMITED
+-- WARRANTY, THE SOFTWARE PROGRAMS CONTAINED IN THIS FILE ARE
+-- PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED
+-- OR IMPLIED, INCLUDING BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES
+-- OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
+--
+-- IN NO EVENT SHALL BATM BE LIABLE FOR ANY DAMAGES WHATSOEVER
+-- INCLUDING WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS
+-- PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION OR
+-- OTHER CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE, OR INABILITY
+-- TO USE, THE SOFTWARE CONTAINED IN THIS FILE.
+--
+-- ----------------------------------------------------------------------------
+
+PRVT-LMM-MIB DEFINITIONS ::= BEGIN
+
+IMPORTS
+ ifIndex
+ FROM IF-MIB
+ switch
+ FROM PRVT-SWITCH-MIB
+ Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-TYPE
+ FROM SNMPv2-SMI
+ TruthValue
+ FROM SNMPv2-TC;
+
+prvtLmmMIB MODULE-IDENTITY
+ LAST-UPDATED "201110110000Z"
+ ORGANIZATION
+ "BATM Advanced Communication"
+ CONTACT-INFO
+ "BATM/Telco Systems Support team
+ Email:
+ For North America: techsupport@telco.com
+ For North Europe: support@batm.de, info@batm.de
+ For the rest of the world: techsupport@telco.com"
+ DESCRIPTION
+ "Initial version. This MIB will configure laser monitoring"
+ REVISION "201110110000Z"
+ DESCRIPTION
+ "Initial release"
+ ::= { switch 172 }
+
+
+prvtLmmNotifications OBJECT IDENTIFIER
+ ::= { prvtLmmMIB 0 }
+
+prvtLmmObjects OBJECT IDENTIFIER
+ ::= { prvtLmmMIB 1 }
+
+prvtLmmShutdown OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable/disable laser monitoring"
+ ::= { prvtLmmObjects 1 }
+
+prvtLmmDebug OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable/Disable laser monitoring"
+ ::= { prvtLmmObjects 2 }
+
+prvtLmmPeriod OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Specify the monitoring interval (sec)."
+ ::= { prvtLmmObjects 3 }
+
+prvtLmmTrap OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable/Disable sending SNMP traps when thresholds are crossed"
+ ::= { prvtLmmObjects 4 }
+
+prvtLmmLog OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable/Disable alert notification logging when thresholds are crossed"
+ ::= { prvtLmmObjects 5 }
+
+prvtLmmLed OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable/Disable LED-alert notifications when thresholds are crossed"
+ ::= { prvtLmmObjects 6 }
+
+prvtLmmTemperatureHighThreshold OBJECT-TYPE
+ SYNTAX Integer32 (-128..128)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Specify the low threshold value for global temperature (-128 up to 128).
+ prvtLmmTemperatureHighThreshold must be higher than prvtLmmTemperatureLowThreshold"
+ ::= { prvtLmmObjects 7 }
+
+prvtLmmTemperatureLowThreshold OBJECT-TYPE
+ SYNTAX Integer32 (-128..128)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Specify the low threshold value for global temperature (-128 up to 128).
+ prvtLmmTemperatureHighThreshold must be higher than prvtLmmTemperatureLowThreshold"
+ ::= { prvtLmmObjects 8 }
+
+prvtLmmRxPowerLowThreshold OBJECT-TYPE
+ SYNTAX Integer32 (-40..8)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Specify the low threshold value for global RX-power (-40 up to 8)
+ prvtLmmRxPowerHighThreshold must be higher than prvtLmmRxPowerLowThreshold"
+ ::= { prvtLmmObjects 9 }
+
+prvtLmmRxPowerHighThreshold OBJECT-TYPE
+ SYNTAX Integer32 (-40..8)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Specify the high threshold value for global RX-power (-40 up to 8)
+ prvtLmmRxPowerHighThreshold must be higher than prvtLmmRxPowerLowThreshold"
+ ::= { prvtLmmObjects 10 }
+
+prvtLmmTxPowerLowThreshold OBJECT-TYPE
+ SYNTAX Integer32 (-40..8)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Specify the low threshold value for global RX-power (-40 up to 8)
+ prvtLmmTxPowerHighThreshold must be higher than prvtLmmTxPowerLowThreshold"
+ ::= { prvtLmmObjects 11 }
+
+prvtLmmTxPowerHighThreshold OBJECT-TYPE
+ SYNTAX Integer32 (-40..8)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Specify the high threshold value for global RX-power (-40 up to 8)
+ prvtLmmTxPowerHighThreshold must be higher than prvtLmmTxPowerLowThreshold"
+ ::= { prvtLmmObjects 12 }
+
+prvtLmmInterfaceTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PrvtLmmInterfaceEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Lmm configuration per ethernet port"
+ ::= { prvtLmmObjects 13 }
+
+prvtLmmInterfaceEntry OBJECT-TYPE
+ SYNTAX PrvtLmmInterfaceEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The Stack table entry"
+ INDEX { ifIndex }
+ ::= { prvtLmmInterfaceTable 1 }
+
+PrvtLmmInterfaceEntry ::= SEQUENCE {
+ prvtLmmInterfaceShutdown TruthValue,
+ prvtLmmInterfaceTempLowThreshold Integer32,
+ prvtLmmInterfaceTempHighThreshold Integer32,
+ prvtLmmInterfaceTempValue Integer32,
+ prvtLmmInterfaceTempThresholdLo Integer32,
+ prvtLmmInterfaceTempThresholdHi Integer32,
+ prvtLmmInterfaceTempTestState TruthValue,
+ prvtLmmInterfaceRxPowerLowThreshold Integer32,
+ prvtLmmInterfaceRxPowerHighThreshold Integer32,
+ prvtLmmInterfaceRxPowerValue Integer32,
+ prvtLmmInterfaceRxPowerThresholdRxLo Integer32,
+ prvtLmmInterfaceRxPowerThresholdRxHi Integer32,
+ prvtLmmInterfaceRxPowerTestState TruthValue,
+ prvtLmmInterfaceTxPowerLowThreshold Integer32,
+ prvtLmmInterfaceTxPowerHighThreshold Integer32,
+ prvtLmmInterfaceTxPowerValue Integer32,
+ prvtLmmInterfaceTxPowerThresholdTxLo Integer32,
+ prvtLmmInterfaceTxPowerThresholdTxHi Integer32,
+ prvtLmmInterfaceTxPowerTestState TruthValue,
+ prvtLmmInterfaceOperStatus TruthValue
+}
+
+prvtLmmInterfaceShutdown OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable/Disable laser monitoring on port"
+ ::= { prvtLmmInterfaceEntry 1 }
+
+prvtLmmInterfaceTempLowThreshold OBJECT-TYPE
+ SYNTAX Integer32 (-128..128)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Specify the low threshold value for port temperature"
+ ::= { prvtLmmInterfaceEntry 2 }
+
+prvtLmmInterfaceTempHighThreshold OBJECT-TYPE
+ SYNTAX Integer32 (-128..128)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Specify the high threshold value for port temperature.
+ Value of prvtLmmInterfaceTempHighThreshold must be greater than
+ prvtLmmInterfaceTempLowThreshold"
+ ::= { prvtLmmInterfaceEntry 3 }
+
+prvtLmmInterfaceTempValue OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Display laser Temperature current value"
+ ::= { prvtLmmInterfaceEntry 4 }
+
+prvtLmmInterfaceTempThresholdLo OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The thresholds read from hardware or set by user"
+ ::= { prvtLmmInterfaceEntry 5 }
+
+prvtLmmInterfaceTempThresholdHi OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The thresholds read from hardware or set by user"
+ ::= { prvtLmmInterfaceEntry 6 }
+
+prvtLmmInterfaceTempTestState OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The state test"
+ ::= { prvtLmmInterfaceEntry 7 }
+
+prvtLmmInterfaceRxPowerLowThreshold OBJECT-TYPE
+ SYNTAX Integer32 (-40..8)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Specify the low threshold value for port RX-power."
+ ::= { prvtLmmInterfaceEntry 8 }
+
+prvtLmmInterfaceRxPowerHighThreshold OBJECT-TYPE
+ SYNTAX Integer32 (-40..8)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Specify the high threshold value for port RX-power.
+ Value of prvtLmmInterfaceRxPowerHighThreshold must be greater than
+ prvtLmmInterfaceRxPowerLowThreshold"
+ ::= { prvtLmmInterfaceEntry 9 }
+
+prvtLmmInterfaceRxPowerValue OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Display laser Rx Power current value"
+ ::= { prvtLmmInterfaceEntry 10 }
+
+prvtLmmInterfaceRxPowerThresholdRxLo OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The thresholds read from hardware or set by user"
+ ::= { prvtLmmInterfaceEntry 11 }
+
+prvtLmmInterfaceRxPowerThresholdRxHi OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The thresholds read from hardware or set by user"
+ ::= { prvtLmmInterfaceEntry 12 }
+
+prvtLmmInterfaceRxPowerTestState OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The state test"
+ ::= { prvtLmmInterfaceEntry 13 }
+
+prvtLmmInterfaceTxPowerLowThreshold OBJECT-TYPE
+ SYNTAX Integer32 (-40..8)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Specify the low threshold value for port TX-power"
+ ::= { prvtLmmInterfaceEntry 14 }
+
+prvtLmmInterfaceTxPowerHighThreshold OBJECT-TYPE
+ SYNTAX Integer32 (-40..8)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Specify the high threshold value for port TX-power
+ Value of prvtLmmInterfaceTxPowerHighThreshold must be greater than
+ prvtLmmInterfaceTxPowerLowThreshold"
+ ::= { prvtLmmInterfaceEntry 15 }
+
+prvtLmmInterfaceTxPowerValue OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Display laser Tx Power current value"
+ ::= { prvtLmmInterfaceEntry 16 }
+
+prvtLmmInterfaceTxPowerThresholdTxLo OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The thresholds read from hardware or set by user"
+ ::= { prvtLmmInterfaceEntry 17 }
+
+prvtLmmInterfaceTxPowerThresholdTxHi OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The thresholds read from hardware or set by user"
+ ::= { prvtLmmInterfaceEntry 18 }
+
+prvtLmmInterfaceTxPowerTestState OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The state test"
+ ::= { prvtLmmInterfaceEntry 19 }
+
+prvtLmmInterfaceOperStatus OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Operational status"
+ ::= { prvtLmmInterfaceEntry 20 }
+
+prvtLmmTemperatureThresholdCrossed NOTIFICATION-TYPE
+ OBJECTS { prvtLmmInterfaceTempValue,
+ prvtLmmInterfaceTempThresholdHi,
+ prvtLmmInterfaceTempThresholdLo }
+ STATUS current
+ DESCRIPTION
+ "The prvtLmmTemperatureThresholdCrossed shall be generated
+ when prvtLmmInterfaceTempValue rises above prvtLmmInterfaceTempThresholdHi
+ or falls below prvtLmmInterfaceTempThresholdLo. Also the
+ notification shall be generated when prvtLmmInterfaceTempValue
+ returns to the normal range between prvtLmmInterfaceTempThresholdHi
+ and prvtLmmInterfaceTempThresholdLo."
+ ::= { prvtLmmNotifications 1 }
+
+prvtLmmTxPowerThresholdCrossed NOTIFICATION-TYPE
+ OBJECTS { prvtLmmInterfaceTxPowerValue,
+ prvtLmmInterfaceTxPowerThresholdTxHi,
+ prvtLmmInterfaceTxPowerThresholdTxLo }
+ STATUS current
+ DESCRIPTION
+ "The prvtLmmTxPowerThresholdCrossed shall be generated
+ when prvtLmmInterfaceTxPowerValue rises above prvtLmmInterfaceTxPowerThresholdTxHi
+ or falls below prvtLmmInterfaceTxPowerThresholdTxLo. Also the
+ notification shall be generated when prvtLmmInterfaceTxPowerValue
+ returns to the normal range between prvtLmmInterfaceTxPowerThresholdTxHi
+ and prvtLmmInterfaceTxPowerThresholdTxLo."
+ ::= { prvtLmmNotifications 2 }
+
+prvtLmmRxPowerThresholdCrossed NOTIFICATION-TYPE
+ OBJECTS { prvtLmmInterfaceRxPowerValue,
+ prvtLmmInterfaceRxPowerThresholdRxHi,
+ prvtLmmInterfaceRxPowerThresholdRxLo }
+ STATUS current
+ DESCRIPTION
+ "The prvtLmmRxPowerThresholdCrossed shall be generated
+ when prvtLmmInterfaceRxPowerValue rises above prvtLmmInterfaceRxPowerThresholdRxHi
+ or falls below prvtLmmInterfaceRxPowerThresholdRxLo. Also the
+ notification shall be generated when prvtLmmInterfaceRxPowerValue
+ returns to the normal range between prvtLmmInterfaceRxPowerThresholdRxHi
+ and prvtLmmInterfaceRxPowerThresholdRxLo."
+ ::= { prvtLmmNotifications 3 }
+
+END -- end of module PRVT-LMM-MIB.