summaryrefslogtreecommitdiff
path: root/MIBS/vertiv/VERTIV-V5-MIB
diff options
context:
space:
mode:
authorDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
committerDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
commit98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch)
tree9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/vertiv/VERTIV-V5-MIB
downloadmibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.tar.gz
mibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.zip
Initial commitHEADmain
Diffstat (limited to 'MIBS/vertiv/VERTIV-V5-MIB')
-rw-r--r--MIBS/vertiv/VERTIV-V5-MIB6471
1 files changed, 6471 insertions, 0 deletions
diff --git a/MIBS/vertiv/VERTIV-V5-MIB b/MIBS/vertiv/VERTIV-V5-MIB
new file mode 100644
index 0000000..c6e0644
--- /dev/null
+++ b/MIBS/vertiv/VERTIV-V5-MIB
@@ -0,0 +1,6471 @@
+VERTIV-V5-MIB DEFINITIONS ::= BEGIN
+
+IMPORTS
+
+DisplayString, TruthValue, MacAddress FROM SNMPv2-TC
+SnmpAdminString FROM SNMP-FRAMEWORK-MIB
+MODULE-IDENTITY, OBJECT-TYPE, enterprises, Integer32,
+Gauge32, NOTIFICATION-TYPE, OBJECT-IDENTITY FROM SNMPv2-SMI
+sysName FROM SNMPv2-MIB;
+
+vertiv MODULE-IDENTITY
+ LAST-UPDATED "202001070000Z"
+ ORGANIZATION "Vertiv"
+ CONTACT-INFO "support@geistglobal.com"
+ DESCRIPTION
+ "The MIB for Vertiv products"
+
+ REVISION "202001070000Z"
+ DESCRIPTION
+ "Updates for VRC spec change"
+
+ REVISION "201909300000Z"
+ DESCRIPTION
+ "Added hostname, alarm/warning count, and manufacturer to deviceInfo"
+
+ REVISION "201909120000Z"
+ DESCRIPTION
+ "Added SN-2D door switch sensor"
+
+ REVISION "201908300000Z"
+ DESCRIPTION
+ "Removed current min, max, and peak fields from pdu phase, line,
+ breaker, and outlet tables
+ Removed voltage min, max, and peak fields from pdu phase, line,
+ breaker, and outlet tables
+ Removed minmax reset value from pduOutletMeterReset
+ Added balance field to pdu phase table"
+
+ REVISION "201906060000Z"
+ DESCRIPTION
+ "Updated pduOutletSwitchControl description"
+
+ REVISION "201905070000Z"
+ DESCRIPTION
+ "Changed productMacAddress type to MacAddress"
+
+ REVISION "201904300000Z"
+ DESCRIPTION
+ "Added remote humidity-only sensor"
+
+ REVISION "201903070000Z"
+ DESCRIPTION
+ "Added VRC support"
+
+ REVISION "201801190000Z"
+ DESCRIPTION
+ "Modified pduOutletSwitchTable to support outlet actions with delays"
+
+ REVISION "201709190000Z"
+ DESCRIPTION
+ "Changed SYNTAX of objects, with a UTF-8 encoded string value, to
+ SnmpAdminString"
+
+ REVISION "201708100000Z"
+ DESCRIPTION
+ "Added pduBreakerCurrentPeak, pduLineCurrentPeak,
+ pduOutletMeterCurrentPeak, pduPhaseVoltagePeak, and
+ pduPhaseCurrentPeak
+ Updated object descriptions, indicating which fields are not supported
+ on all platforms"
+
+ REVISION "201705100000Z"
+ DESCRIPTION
+ "Added trapObj group with trap payload objects
+ Added additional payload objects to trap definitions"
+
+ REVISION "201704050000Z"
+ DESCRIPTION
+ "Added productPlatform to deviceInfo group
+ Added product identity entries"
+
+ REVISION "201606300000Z"
+ DESCRIPTION
+ "Raven version"
+
+ REVISION "201209110000Z"
+ DESCRIPTION
+ "Original version"
+ ::= { enterprises 21239 }
+
+v5 OBJECT IDENTIFIER ::= { vertiv 5 }
+
+imd OBJECT IDENTIFIER ::= { v5 2 }
+
+--###########################################################################################--
+--deviceInfo--
+--###########################################################################################--
+
+deviceInfo OBJECT IDENTIFIER ::= { imd 1 }
+
+productTitle OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Product name"
+ ::= { deviceInfo 1 }
+
+productVersion OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Product version"
+ ::= { deviceInfo 2 }
+
+productFriendlyName OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "User-assigned name"
+ ::= { deviceInfo 3 }
+
+productMacAddress OBJECT-TYPE
+ SYNTAX MacAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Product's unique MAC address"
+ ::= { deviceInfo 4 }
+
+deviceCount OBJECT-TYPE
+ SYNTAX Integer32(0..16)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of devices on unit"
+ ::= { deviceInfo 6 }
+
+temperatureUnits OBJECT-TYPE
+ SYNTAX INTEGER {
+ fahrenheit(0),
+ celsius(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Current units for temperature/dewpoint values:
+ 0 = Degrees Fahrenheit
+ 1 = Degrees Celsius"
+ ::= { deviceInfo 7 }
+
+productModelNumber OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Product model number (factory-assigned)"
+ ::= { deviceInfo 8 }
+
+productPartNumber OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Product part number (factory-assigned)"
+ ::= { deviceInfo 9 }
+
+productSerialNumber OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Product serial number (factory-assigned)"
+ ::= { deviceInfo 10 }
+
+productPlatform OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Product platform"
+ ::= { deviceInfo 11 }
+
+productHostname OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Product hostname"
+ ::= { deviceInfo 12 }
+
+productAlarmCount OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of alarms currently tripped"
+ ::= { deviceInfo 13 }
+
+productWarnCount OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of warnings currently tripped"
+ ::= { deviceInfo 14 }
+
+productManufacturer OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Product manufacturer"
+ ::= { deviceInfo 15 }
+
+--###########################################################################################--
+--pdu--
+--###########################################################################################--
+
+pdu OBJECT IDENTIFIER ::= { imd 3 }
+
+--###########################################################################################--
+--pduMainTable--
+--###########################################################################################--
+
+pduMainTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PduMainEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "PDU general information"
+ ::= { pdu 1 }
+
+pduMainEntry OBJECT-TYPE
+ SYNTAX PduMainEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry in the pduMainTable table: each entry contains an index
+ and other sensor details"
+ INDEX { pduMainIndex }
+ ::= { pduMainTable 1 }
+
+PduMainEntry ::= SEQUENCE {
+ pduMainIndex Integer32,
+ pduMainSerial DisplayString,
+ pduMainName SnmpAdminString,
+ pduMainLabel SnmpAdminString,
+ pduMainAvail Gauge32,
+ pduMeterType INTEGER,
+ pduTotalName SnmpAdminString,
+ pduTotalLabel SnmpAdminString,
+ pduTotalRealPower Gauge32,
+ pduTotalApparentPower Gauge32,
+ pduTotalPowerFactor Gauge32,
+ pduTotalEnergy Gauge32
+}
+
+pduMainIndex OBJECT-TYPE
+ SYNTAX Integer32(1..100)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table entry index value"
+ ::= { pduMainEntry 1 }
+
+pduMainSerial OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Serial number"
+ ::= { pduMainEntry 2 }
+
+pduMainName OBJECT-TYPE
+ SYNTAX SnmpAdminString(SIZE (1..25))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "PDU name (factory-assigned)"
+ ::= { pduMainEntry 3 }
+
+pduMainLabel OBJECT-TYPE
+ SYNTAX SnmpAdminString(SIZE (0..25))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "PDU label (user-defined)"
+ ::= { pduMainEntry 4 }
+
+pduMainAvail OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Device availability:
+ 0 = Unavailable
+ 1 = Available
+ 2 = Partially Unavailable"
+ ::= { pduMainEntry 5 }
+
+pduMeterType OBJECT-TYPE
+ SYNTAX INTEGER {
+ wye(0),
+ delta(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Current meter type:
+ 0 = Wye
+ 1 = Delta"
+ ::= { pduMainEntry 6 }
+
+pduTotalName OBJECT-TYPE
+ SYNTAX SnmpAdminString(SIZE (1..25))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total name (factory-assigned)"
+ ::= { pduMainEntry 7 }
+
+pduTotalLabel OBJECT-TYPE
+ SYNTAX SnmpAdminString(SIZE (0..25))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Total label (user-defined)"
+ ::= { pduMainEntry 8 }
+
+pduTotalRealPower OBJECT-TYPE
+ SYNTAX Gauge32(0..9999)
+ UNITS "watts"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "PDU total real power"
+ ::= { pduMainEntry 9 }
+
+pduTotalApparentPower OBJECT-TYPE
+ SYNTAX Gauge32(0..9999)
+ UNITS "volt-amps"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "PDU total apparent power"
+ ::= { pduMainEntry 10 }
+
+pduTotalPowerFactor OBJECT-TYPE
+ SYNTAX Gauge32(0..100)
+ UNITS "%"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "PDU total power factor"
+ ::= { pduMainEntry 11 }
+
+pduTotalEnergy OBJECT-TYPE
+ SYNTAX Gauge32(0..9999000)
+ UNITS "watt-hours"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "PDU total accumulated energy in watt-hours"
+ ::= { pduMainEntry 12 }
+
+--###########################################################################################--
+--pduPhaseTable--
+--###########################################################################################--
+
+pduPhaseTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PduPhaseEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "PDU phases information"
+ ::= { pdu 2 }
+
+pduPhaseEntry OBJECT-TYPE
+ SYNTAX PduPhaseEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry in the pduPhaseTable table: each entry contains an index
+ and other sensor details"
+ INDEX { pduPhaseIndex }
+ ::= { pduPhaseTable 1 }
+
+PduPhaseEntry ::= SEQUENCE {
+ pduPhaseIndex Integer32,
+ pduPhaseName SnmpAdminString,
+ pduPhaseLabel SnmpAdminString,
+ pduPhaseVoltage Gauge32,
+ pduPhaseCurrent Gauge32,
+ pduPhaseRealPower Gauge32,
+ pduPhaseApparentPower Gauge32,
+ pduPhasePowerFactor Gauge32,
+ pduPhaseEnergy Gauge32,
+ pduPhaseBalance Gauge32,
+ pduPhaseCurrentCrestFactor Gauge32
+}
+
+pduPhaseIndex OBJECT-TYPE
+ SYNTAX Integer32(1..100)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table entry index value"
+ ::= { pduPhaseEntry 1 }
+
+pduPhaseName OBJECT-TYPE
+ SYNTAX SnmpAdminString(SIZE (0..25))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "PDU phase name (factory-assigned)"
+ ::= { pduPhaseEntry 2 }
+
+pduPhaseLabel OBJECT-TYPE
+ SYNTAX SnmpAdminString(SIZE (1..25))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "PDU phase label (user-defined)"
+ ::= { pduPhaseEntry 3 }
+
+pduPhaseVoltage OBJECT-TYPE
+ SYNTAX Gauge32(0..3100)
+ UNITS "decivolts (rms)"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "PDU phase voltage in tenths of a volt"
+ ::= { pduPhaseEntry 4 }
+
+pduPhaseCurrent OBJECT-TYPE
+ SYNTAX Gauge32(0..9900)
+ UNITS "centiamps (rms)"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "PDU phase current reading in hundredths of an amp"
+ ::= { pduPhaseEntry 8 }
+
+pduPhaseRealPower OBJECT-TYPE
+ SYNTAX Gauge32(0..9999)
+ UNITS "watts"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Real power for phase in watts"
+ ::= { pduPhaseEntry 12 }
+
+pduPhaseApparentPower OBJECT-TYPE
+ SYNTAX Gauge32(0..9999)
+ UNITS "volt-amps"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Apparent power for phase in volt-amps"
+ ::= { pduPhaseEntry 13 }
+
+pduPhasePowerFactor OBJECT-TYPE
+ SYNTAX Gauge32(0..100)
+ UNITS "%"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Power factor for phase"
+ ::= { pduPhaseEntry 14 }
+
+pduPhaseEnergy OBJECT-TYPE
+ SYNTAX Gauge32(0..9999000)
+ UNITS "watt-hours"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Accumulated energy for phase in watt-hours"
+ ::= { pduPhaseEntry 15 }
+
+pduPhaseBalance OBJECT-TYPE
+ SYNTAX Gauge32(0..100)
+ UNITS "%"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Phase balance as percent"
+ ::= { pduPhaseEntry 17 }
+
+pduPhaseCurrentCrestFactor OBJECT-TYPE
+ SYNTAX Gauge32(0..9999)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Current crest factor for phase, in hundredths"
+ ::= { pduPhaseEntry 19 }
+
+--###########################################################################################--
+--pduBreakerTable--
+--###########################################################################################--
+
+pduBreakerTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PduBreakerEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "PDU breaker information"
+ ::= { pdu 3 }
+
+pduBreakerEntry OBJECT-TYPE
+ SYNTAX PduBreakerEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry in the pduBreakerTable table: each entry contains an index
+ and other sensor details"
+ INDEX { pduBreakerIndex }
+ ::= { pduBreakerTable 1 }
+
+PduBreakerEntry ::= SEQUENCE {
+ pduBreakerIndex Integer32,
+ pduBreakerName SnmpAdminString,
+ pduBreakerLabel SnmpAdminString,
+ pduBreakerCurrent Gauge32,
+ pduBreakerVoltage Gauge32,
+ pduBreakerRealPower Gauge32,
+ pduBreakerApparentPower Gauge32,
+ pduBreakerPowerFactor Gauge32,
+ pduBreakerEnergy Gauge32
+}
+
+pduBreakerIndex OBJECT-TYPE
+ SYNTAX Integer32(1..100)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table entry index value"
+ ::= { pduBreakerEntry 1 }
+
+pduBreakerName OBJECT-TYPE
+ SYNTAX SnmpAdminString(SIZE (1..25))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "PDU breaker name (factory-assigned)"
+ ::= { pduBreakerEntry 2 }
+
+pduBreakerLabel OBJECT-TYPE
+ SYNTAX SnmpAdminString(SIZE (0..25))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "PDU breaker label (user-defined)"
+ ::= { pduBreakerEntry 3 }
+
+pduBreakerCurrent OBJECT-TYPE
+ SYNTAX Gauge32(0..9900)
+ UNITS "centiamps (rms)"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "PDU breaker current reading in hundredths of an amp"
+ ::= { pduBreakerEntry 4 }
+
+pduBreakerVoltage OBJECT-TYPE
+ SYNTAX Gauge32(0..3100)
+ UNITS "decivolts (rms)"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "PDU breaker voltage in tenths of a volt. This object may not exist on
+ all platforms, due to hardware differences."
+ ::= { pduBreakerEntry 8 }
+
+pduBreakerRealPower OBJECT-TYPE
+ SYNTAX Gauge32(0..9999)
+ UNITS "watts"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Real power for breaker in watts. This object may not exist on all
+ platforms, due to hardware differences."
+ ::= { pduBreakerEntry 12 }
+
+pduBreakerApparentPower OBJECT-TYPE
+ SYNTAX Gauge32(0..9999)
+ UNITS "volt-amps"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Apparent power for breaker in volt-amps. This object may not exist on
+ all platforms, due to hardware differences."
+ ::= { pduBreakerEntry 13 }
+
+pduBreakerPowerFactor OBJECT-TYPE
+ SYNTAX Gauge32(0..100)
+ UNITS "%"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Power factor for breaker. This object may not exist on all platforms,
+ due to hardware differences."
+ ::= { pduBreakerEntry 14 }
+
+pduBreakerEnergy OBJECT-TYPE
+ SYNTAX Gauge32(0..9999000)
+ UNITS "watt-hours"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Accumulated energy for breaker in watt-hours. This object may not
+ exist on all platforms, due to hardware differences."
+ ::= { pduBreakerEntry 15 }
+
+--###########################################################################################--
+--pduLineTable--
+--###########################################################################################--
+
+pduLineTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PduLineEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "PDU line current information"
+ ::= { pdu 4 }
+
+pduLineEntry OBJECT-TYPE
+ SYNTAX PduLineEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry in the pduLineTable table: each entry contains an index
+ and other sensor details"
+ INDEX { pduLineIndex }
+ ::= { pduLineTable 1 }
+
+PduLineEntry ::= SEQUENCE {
+ pduLineIndex Integer32,
+ pduLineName SnmpAdminString,
+ pduLineLabel SnmpAdminString,
+ pduLineCurrent Gauge32
+}
+
+pduLineIndex OBJECT-TYPE
+ SYNTAX Integer32(1..100)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table entry index value"
+ ::= { pduLineEntry 1 }
+
+pduLineName OBJECT-TYPE
+ SYNTAX SnmpAdminString(SIZE (1..25))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "PDU line name (factory-assigned)"
+ ::= { pduLineEntry 2 }
+
+pduLineLabel OBJECT-TYPE
+ SYNTAX SnmpAdminString(SIZE (0..25))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "PDU line label (user-defined)"
+ ::= { pduLineEntry 3 }
+
+pduLineCurrent OBJECT-TYPE
+ SYNTAX Gauge32(0..9900)
+ UNITS "centiamps (rms)"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "PDU line current reading in hundredths of an amp"
+ ::= { pduLineEntry 4 }
+
+--###########################################################################################--
+--pduOutletSwitchTable--
+--###########################################################################################--
+
+pduOutletSwitchTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PduOutletSwitchEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Data, config and control for outlets with switching"
+ ::= { pdu 5 }
+
+pduOutletSwitchEntry OBJECT-TYPE
+ SYNTAX PduOutletSwitchEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry in the pduOutletSwitchTable table: each entry contains an index
+ and other sensor details"
+ INDEX { pduOutletSwitchIndex }
+ ::= { pduOutletSwitchTable 1 }
+
+PduOutletSwitchEntry ::= SEQUENCE {
+ pduOutletSwitchIndex Integer32,
+ pduOutletSwitchName SnmpAdminString,
+ pduOutletSwitchLabel SnmpAdminString,
+ pduOutletSwitchState INTEGER,
+ pduOutletSwitchRelayFailure TruthValue,
+ pduOutletSwitchControl INTEGER,
+ pduOutletSwitchTimeToAction Integer32,
+ pduOutletSwitchOnDelay Integer32,
+ pduOutletSwitchOffDelay Integer32,
+ pduOutletSwitchRebootDelay Integer32,
+ pduOutletSwitchRebootHoldDelay Integer32,
+ pduOutletSwitchPoaAction INTEGER,
+ pduOutletSwitchPoaDelay Integer32
+}
+
+pduOutletSwitchIndex OBJECT-TYPE
+ SYNTAX Integer32(1..100)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table entry index value"
+ ::= { pduOutletSwitchEntry 1 }
+
+pduOutletSwitchName OBJECT-TYPE
+ SYNTAX SnmpAdminString(SIZE (1..25))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "PDU outlet name (factory-assigned)"
+ ::= { pduOutletSwitchEntry 2 }
+
+pduOutletSwitchLabel OBJECT-TYPE
+ SYNTAX SnmpAdminString(SIZE (0..25))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "PDU outlet label (user-defined)"
+ ::= { pduOutletSwitchEntry 3 }
+
+pduOutletSwitchState OBJECT-TYPE
+ SYNTAX INTEGER {
+ on(1),
+ off(2),
+ on2off(3),
+ off2on(4),
+ rebootOn(5),
+ rebootOff(6),
+ unavailable(7)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Switch state of the outlet:
+ 1 = Outlet is on
+ 2 = Outlet is off
+ 3 = Outlet is on, but will turn off after a delay
+ 4 = Outlet is off, but will turn on after a delay
+ 5 = Starting reboot cycle, outlet is on, but will go to the
+ rebootOff(6) state after a delay
+ 6 = Rebooting, outlet is off, but it will turn on after a delay
+ 7 = Cannot get outlet state"
+ ::= { pduOutletSwitchEntry 4 }
+
+pduOutletSwitchRelayFailure OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Tells if the outlet relay has failed. In normal operation, the value
+ will be false(2)."
+ ::= { pduOutletSwitchEntry 5 }
+
+pduOutletSwitchControl OBJECT-TYPE
+ SYNTAX INTEGER {
+ cancel(1),
+ on(2),
+ onAfterDelay(3),
+ off(4),
+ offAfterDelay(5),
+ reboot(6),
+ rebootAfterDelay(7),
+ none(8)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Used for manual control of the outlet. If the outlet is in manual
+ mode, this field can be set to one of the following values:
+ 1 = Cancel pending operation
+ 2 = Turn outlet on
+ 3 = After delay (pduOutletSwitchOnDelay), turn outlet on
+ 4 = Turn outlet off
+ 5 = After delay (pduOutletSwitchOffDelay), turn outlet off
+ 6 = Reboot: turn off, delay (pduOutletSwitchRebootHoldDelay), turn
+ outlet back on
+ 7 = After delay (pduOutletSwitchRebootDelay), reboot outlet
+ When not in manual mode, setting this field will give an
+ inconsistentValue error. Returns none(8) for all get requests."
+ ::= { pduOutletSwitchEntry 6 }
+
+pduOutletSwitchTimeToAction OBJECT-TYPE
+ SYNTAX Integer32(0..600)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Seconds until an outlet state change. The value of
+ pduOutletSwitchState tells what state the outlet will be set, after
+ the delay."
+ ::= { pduOutletSwitchEntry 7 }
+
+pduOutletSwitchOnDelay OBJECT-TYPE
+ SYNTAX Integer32(0..600)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Seconds to wait before powering on the outlet, during onAfterDelay(3)
+ operation. Changing this value has no effect on pending actions."
+ ::= { pduOutletSwitchEntry 8 }
+
+pduOutletSwitchOffDelay OBJECT-TYPE
+ SYNTAX Integer32(0..600)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Seconds to wait before powering off the outlet, during
+ offAfterDelay(5) operation. Changing this value has no effect on
+ pending actions."
+ ::= { pduOutletSwitchEntry 9 }
+
+pduOutletSwitchRebootDelay OBJECT-TYPE
+ SYNTAX Integer32(0..600)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Seconds to wait before powering off the outlet, during
+ rebootAfterDelay(7) operation. Changing this value has no effect on
+ pending actions. See pduOutletSwitchControl for more info."
+ ::= { pduOutletSwitchEntry 10 }
+
+pduOutletSwitchRebootHoldDelay OBJECT-TYPE
+ SYNTAX Integer32(0..600)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Seconds to hold the outlet off, before powering on the outlet, during
+ rebootAfterDelay(7) operation. Changing this value has no effect on
+ pending actions. See pduOutletSwitchControl for more info."
+ ::= { pduOutletSwitchEntry 11 }
+
+pduOutletSwitchPoaAction OBJECT-TYPE
+ SYNTAX INTEGER {
+ on(1),
+ off(2),
+ last(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The outlet is set to this state during power-up. The action can be
+ have one the following values:
+ 1 = Outlet will be turned on
+ 2 = Outlet will stay off
+ 3 = Outlet will be set to last known state"
+ ::= { pduOutletSwitchEntry 12 }
+
+pduOutletSwitchPoaDelay OBJECT-TYPE
+ SYNTAX Integer32(0..600)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Seconds to wait before setting the outlet to the
+ pduOutletSwitchPoaAction state. The delay starts at power-up."
+ ::= { pduOutletSwitchEntry 13 }
+
+--###########################################################################################--
+--pduOutletMeterTable--
+--###########################################################################################--
+
+pduOutletMeterTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PduOutletMeterEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Metering data for outlets that support this feature"
+ ::= { pdu 6 }
+
+pduOutletMeterEntry OBJECT-TYPE
+ SYNTAX PduOutletMeterEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry in the pduOutletMeterTable table: each entry contains an index
+ and other sensor details"
+ INDEX { pduOutletMeterIndex }
+ ::= { pduOutletMeterTable 1 }
+
+PduOutletMeterEntry ::= SEQUENCE {
+ pduOutletMeterIndex Integer32,
+ pduOutletMeterName SnmpAdminString,
+ pduOutletMeterLabel SnmpAdminString,
+ pduOutletMeterVoltage Gauge32,
+ pduOutletMeterCurrent Gauge32,
+ pduOutletMeterRealPower Gauge32,
+ pduOutletMeterApparentPower Gauge32,
+ pduOutletMeterPowerFactor Gauge32,
+ pduOutletMeterEnergy Gauge32,
+ pduOutletMeterReset INTEGER,
+ pduOutletCurrentCrestFactor Gauge32
+}
+
+pduOutletMeterIndex OBJECT-TYPE
+ SYNTAX Integer32(1..100)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table entry index value"
+ ::= { pduOutletMeterEntry 1 }
+
+pduOutletMeterName OBJECT-TYPE
+ SYNTAX SnmpAdminString(SIZE (1..25))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "PDU outlet name (factory-assigned)"
+ ::= { pduOutletMeterEntry 2 }
+
+pduOutletMeterLabel OBJECT-TYPE
+ SYNTAX SnmpAdminString(SIZE (0..25))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "PDU outlet label (user-defined)"
+ ::= { pduOutletMeterEntry 3 }
+
+pduOutletMeterVoltage OBJECT-TYPE
+ SYNTAX Gauge32(0..3100)
+ UNITS "decivolts (rms)"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "PDU outlet voltage in tenths of a volt"
+ ::= { pduOutletMeterEntry 4 }
+
+pduOutletMeterCurrent OBJECT-TYPE
+ SYNTAX Gauge32(0..9900)
+ UNITS "centiamps (rms)"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "PDU outlet current reading in hundredths of an amp"
+ ::= { pduOutletMeterEntry 8 }
+
+pduOutletMeterRealPower OBJECT-TYPE
+ SYNTAX Gauge32(0..9999)
+ UNITS "watts"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Real power for outlet in watts"
+ ::= { pduOutletMeterEntry 12 }
+
+pduOutletMeterApparentPower OBJECT-TYPE
+ SYNTAX Gauge32(0..9999)
+ UNITS "volt-amps"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Apparent power for outlet in volt-amps"
+ ::= { pduOutletMeterEntry 13 }
+
+pduOutletMeterPowerFactor OBJECT-TYPE
+ SYNTAX Gauge32(0..100)
+ UNITS "%"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Power factor for outlet"
+ ::= { pduOutletMeterEntry 14 }
+
+pduOutletMeterEnergy OBJECT-TYPE
+ SYNTAX Gauge32(0..9999000)
+ UNITS "watt-hours"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Accumulated energy for outlet in watt-hours"
+ ::= { pduOutletMeterEntry 15 }
+
+pduOutletMeterReset OBJECT-TYPE
+ SYNTAX INTEGER {
+ resetEnergy(1),
+ none(8)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Used to reset energy. If read, the value is none(8). It can be set to
+ resetEnergy(1), which sets outlet energy to 0"
+ ::= { pduOutletMeterEntry 16 }
+
+pduOutletCurrentCrestFactor OBJECT-TYPE
+ SYNTAX Gauge32(0..9999)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Current crest factor for outlet, in hundredths"
+ ::= { pduOutletMeterEntry 19 }
+
+--###########################################################################################--
+--tempSensorTable--
+--###########################################################################################--
+
+tempSensorTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TempSensorEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Remote Temperature (RT) sensor"
+ ::= { imd 4 }
+
+tempSensorEntry OBJECT-TYPE
+ SYNTAX TempSensorEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry in the tempSensorTable table: each entry contains an index
+ and other sensor details"
+ INDEX { tempSensorIndex }
+ ::= { tempSensorTable 1 }
+
+TempSensorEntry ::= SEQUENCE {
+ tempSensorIndex Integer32,
+ tempSensorSerial DisplayString,
+ tempSensorLabel SnmpAdminString,
+ tempSensorAvail Gauge32,
+ tempSensorTemp Integer32
+}
+
+tempSensorIndex OBJECT-TYPE
+ SYNTAX Integer32(1..100)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table entry index value"
+ ::= { tempSensorEntry 1 }
+
+tempSensorSerial OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Serial number"
+ ::= { tempSensorEntry 2 }
+
+tempSensorLabel OBJECT-TYPE
+ SYNTAX SnmpAdminString(SIZE (0..25))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "User-defined label"
+ ::= { tempSensorEntry 3 }
+
+tempSensorAvail OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Device availability:
+ 0 = Unavailable
+ 1 = Available
+ 2 = Partially Unavailable"
+ ::= { tempSensorEntry 4 }
+
+tempSensorTemp OBJECT-TYPE
+ SYNTAX Integer32(-400..2540)
+ UNITS "decidegrees"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Temperature in tenths of a degree. Units are given by temperatureUnits
+ field in deviceInfo."
+ ::= { tempSensorEntry 5 }
+
+--###########################################################################################--
+--airFlowSensorTable--
+--###########################################################################################--
+
+airFlowSensorTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AirFlowSensorEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Remote Airflow, Humidity, Temperature and Dewpoint (AFHT3) Sensor"
+ ::= { imd 5 }
+
+airFlowSensorEntry OBJECT-TYPE
+ SYNTAX AirFlowSensorEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry in the airFlowSensorTable table: each entry contains an index
+ and other sensor details"
+ INDEX { airFlowSensorIndex }
+ ::= { airFlowSensorTable 1 }
+
+AirFlowSensorEntry ::= SEQUENCE {
+ airFlowSensorIndex Integer32,
+ airFlowSensorSerial DisplayString,
+ airFlowSensorLabel SnmpAdminString,
+ airFlowSensorAvail Gauge32,
+ airFlowSensorTemp Integer32,
+ airFlowSensorFlow Integer32,
+ airFlowSensorHumidity Integer32,
+ airFlowSensorDewPoint Integer32
+}
+
+airFlowSensorIndex OBJECT-TYPE
+ SYNTAX Integer32(1..100)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table entry index value"
+ ::= { airFlowSensorEntry 1 }
+
+airFlowSensorSerial OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Serial number"
+ ::= { airFlowSensorEntry 2 }
+
+airFlowSensorLabel OBJECT-TYPE
+ SYNTAX SnmpAdminString(SIZE (0..25))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "User-defined label"
+ ::= { airFlowSensorEntry 3 }
+
+airFlowSensorAvail OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Device availability:
+ 0 = Unavailable
+ 1 = Available
+ 2 = Partially Unavailable"
+ ::= { airFlowSensorEntry 4 }
+
+airFlowSensorTemp OBJECT-TYPE
+ SYNTAX Integer32(-400..2540)
+ UNITS "decidegrees"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Temperature reading in tenths of a degree. Units are given by
+ temperatureUnits field in deviceInfo."
+ ::= { airFlowSensorEntry 5 }
+
+airFlowSensorFlow OBJECT-TYPE
+ SYNTAX Integer32(0..100)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Airflow reading. Still air will be less than 20, while rushing air
+ will be around 100."
+ ::= { airFlowSensorEntry 6 }
+
+airFlowSensorHumidity OBJECT-TYPE
+ SYNTAX Integer32(0..100)
+ UNITS "%"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Humidity reading"
+ ::= { airFlowSensorEntry 7 }
+
+airFlowSensorDewPoint OBJECT-TYPE
+ SYNTAX Integer32(-400..2540)
+ UNITS "decidegrees"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Dewpoint reading in tenths of a degree. Units are given by
+ temperatureUnits field in deviceInfo."
+ ::= { airFlowSensorEntry 8 }
+
+--###########################################################################################--
+--t3hdSensorTable--
+--###########################################################################################--
+
+t3hdSensorTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF T3hdSensorEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Remote Temperature x 3, Humidity and Dewpoint Sensor"
+ ::= { imd 8 }
+
+t3hdSensorEntry OBJECT-TYPE
+ SYNTAX T3hdSensorEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry in the t3hdSensorTable table: each entry contains an index
+ and other sensor details"
+ INDEX { t3hdSensorIndex }
+ ::= { t3hdSensorTable 1 }
+
+T3hdSensorEntry ::= SEQUENCE {
+ t3hdSensorIndex Integer32,
+ t3hdSensorSerial DisplayString,
+ t3hdSensorLabel SnmpAdminString,
+ t3hdSensorAvail Gauge32,
+ t3hdSensorIntLabel SnmpAdminString,
+ t3hdSensorIntTemp Integer32,
+ t3hdSensorIntHumidity Integer32,
+ t3hdSensorIntDewPoint Integer32,
+ t3hdSensorExtAAvail Gauge32,
+ t3hdSensorExtALabel SnmpAdminString,
+ t3hdSensorExtATemp Integer32,
+ t3hdSensorExtBAvail Gauge32,
+ t3hdSensorExtBLabel SnmpAdminString,
+ t3hdSensorExtBTemp Integer32
+}
+
+t3hdSensorIndex OBJECT-TYPE
+ SYNTAX Integer32(1..100)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table entry index value"
+ ::= { t3hdSensorEntry 1 }
+
+t3hdSensorSerial OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Serial number"
+ ::= { t3hdSensorEntry 2 }
+
+t3hdSensorLabel OBJECT-TYPE
+ SYNTAX SnmpAdminString(SIZE (0..25))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "User-defined label"
+ ::= { t3hdSensorEntry 3 }
+
+t3hdSensorAvail OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Device availability:
+ 0 = Unavailable
+ 1 = Available
+ 2 = Partially Unavailable"
+ ::= { t3hdSensorEntry 4 }
+
+t3hdSensorIntLabel OBJECT-TYPE
+ SYNTAX SnmpAdminString(SIZE (0..25))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Internal label (user-defined)"
+ ::= { t3hdSensorEntry 5 }
+
+t3hdSensorIntTemp OBJECT-TYPE
+ SYNTAX Integer32(-400..2540)
+ UNITS "decidegrees"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Internal temperature in tenths of a degree. Units are given by
+ temperatureUnits field in deviceInfo."
+ ::= { t3hdSensorEntry 6 }
+
+t3hdSensorIntHumidity OBJECT-TYPE
+ SYNTAX Integer32(0..100)
+ UNITS "%"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Internal humidity"
+ ::= { t3hdSensorEntry 7 }
+
+t3hdSensorIntDewPoint OBJECT-TYPE
+ SYNTAX Integer32(-400..2540)
+ UNITS "decidegrees"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Internal dewpoint in tenths of a degree. Units are given by
+ temperatureUnits field in deviceInfo."
+ ::= { t3hdSensorEntry 8 }
+
+t3hdSensorExtAAvail OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "External A status:
+ 0 = Unavailable
+ 1 = Available"
+ ::= { t3hdSensorEntry 9 }
+
+t3hdSensorExtALabel OBJECT-TYPE
+ SYNTAX SnmpAdminString(SIZE (0..25))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "External A label (user-defined)"
+ ::= { t3hdSensorEntry 10 }
+
+t3hdSensorExtATemp OBJECT-TYPE
+ SYNTAX Integer32(-400..2540)
+ UNITS "decidegrees"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "External A temperature in tenths of a degree. Units are given by
+ temperatureUnits field in deviceInfo."
+ ::= { t3hdSensorEntry 11 }
+
+t3hdSensorExtBAvail OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "External B status:
+ 0 = Unavailable
+ 1 = Available"
+ ::= { t3hdSensorEntry 12 }
+
+t3hdSensorExtBLabel OBJECT-TYPE
+ SYNTAX SnmpAdminString(SIZE (0..25))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "External B label (user-defined)"
+ ::= { t3hdSensorEntry 13 }
+
+t3hdSensorExtBTemp OBJECT-TYPE
+ SYNTAX Integer32(-400..2540)
+ UNITS "decidegrees"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "External B temperature in tenths of a degree. Units are given by
+ temperatureUnits field in deviceInfo."
+ ::= { t3hdSensorEntry 14 }
+
+--###########################################################################################--
+--thdSensorTable--
+--###########################################################################################--
+
+thdSensorTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ThdSensorEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Remote Temperature, Humidity, and Dewpoint (THD) Sensor"
+ ::= { imd 9 }
+
+thdSensorEntry OBJECT-TYPE
+ SYNTAX ThdSensorEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry in the thdSensorTable table: each entry contains an index
+ and other sensor details"
+ INDEX { thdSensorIndex }
+ ::= { thdSensorTable 1 }
+
+ThdSensorEntry ::= SEQUENCE {
+ thdSensorIndex Integer32,
+ thdSensorSerial DisplayString,
+ thdSensorLabel SnmpAdminString,
+ thdSensorAvail Gauge32,
+ thdSensorTemp Integer32,
+ thdSensorHumidity Integer32,
+ thdSensorDewPoint Integer32
+}
+
+thdSensorIndex OBJECT-TYPE
+ SYNTAX Integer32(1..100)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table entry index value"
+ ::= { thdSensorEntry 1 }
+
+thdSensorSerial OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Serial number"
+ ::= { thdSensorEntry 2 }
+
+thdSensorLabel OBJECT-TYPE
+ SYNTAX SnmpAdminString(SIZE (0..25))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "User-defined label"
+ ::= { thdSensorEntry 3 }
+
+thdSensorAvail OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Device availability:
+ 0 = Unavailable
+ 1 = Available
+ 2 = Partially Unavailable"
+ ::= { thdSensorEntry 4 }
+
+thdSensorTemp OBJECT-TYPE
+ SYNTAX Integer32(-400..2540)
+ UNITS "decidegrees"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Temperature value in tenths of a degree. Units are given by
+ temperatureUnits field in deviceInfo."
+ ::= { thdSensorEntry 5 }
+
+thdSensorHumidity OBJECT-TYPE
+ SYNTAX Integer32(0..100)
+ UNITS "%"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Humidity value"
+ ::= { thdSensorEntry 6 }
+
+thdSensorDewPoint OBJECT-TYPE
+ SYNTAX Integer32(-400..2540)
+ UNITS "decidegrees"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Dewpoint value in tenths of a degree. Units are given by
+ temperatureUnits field in deviceInfo."
+ ::= { thdSensorEntry 7 }
+
+--###########################################################################################--
+--a2dSensorTable--
+--###########################################################################################--
+
+a2dSensorTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF A2dSensorEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Analog measurement (A2D) sensor (voltage, current, or dry-contact)"
+ ::= { imd 11 }
+
+a2dSensorEntry OBJECT-TYPE
+ SYNTAX A2dSensorEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry in the a2dSensorTable table: each entry contains an index
+ and other sensor details"
+ INDEX { a2dSensorIndex }
+ ::= { a2dSensorTable 1 }
+
+A2dSensorEntry ::= SEQUENCE {
+ a2dSensorIndex Integer32,
+ a2dSensorSerial DisplayString,
+ a2dSensorLabel SnmpAdminString,
+ a2dSensorAvail Gauge32,
+ a2dSensorValue Integer32,
+ a2dSensorDisplayValue SnmpAdminString,
+ a2dSensorMode INTEGER,
+ a2dSensorUnits SnmpAdminString,
+ a2dSensorMin Integer32,
+ a2dSensorMax Integer32,
+ a2dSensorLowLabel SnmpAdminString,
+ a2dSensorHighLabel SnmpAdminString,
+ a2dSensorAnalogLabel SnmpAdminString
+}
+
+a2dSensorIndex OBJECT-TYPE
+ SYNTAX Integer32(1..100)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table entry index value"
+ ::= { a2dSensorEntry 1 }
+
+a2dSensorSerial OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Serial number"
+ ::= { a2dSensorEntry 2 }
+
+a2dSensorLabel OBJECT-TYPE
+ SYNTAX SnmpAdminString(SIZE (0..25))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "User-defined label"
+ ::= { a2dSensorEntry 3 }
+
+a2dSensorAvail OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Device availability:
+ 0 = Unavailable
+ 1 = Available
+ 2 = Partially Unavailable"
+ ::= { a2dSensorEntry 4 }
+
+a2dSensorValue OBJECT-TYPE
+ SYNTAX Integer32(-1000000..1000000)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Analog measurement value, within either a user-defined or preset
+ range, depending on a2dSensorMode."
+ ::= { a2dSensorEntry 5 }
+
+a2dSensorDisplayValue OBJECT-TYPE
+ SYNTAX SnmpAdminString(SIZE (0..25))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "For current/voltage modes, the analog value is given as a string. In
+ binary modes, the value is either a2dSensorLowLabel or
+ a2dSensorHighLabel, based on a2dSensorValue."
+ ::= { a2dSensorEntry 6 }
+
+a2dSensorMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ door(1),
+ powerFailure(2),
+ flood(3),
+ wscLeak(4),
+ wscFault(5),
+ smoke(6),
+ ivsNegGnd(7),
+ ivsPosGnd(8),
+ customVoltage(9),
+ customBinary(10),
+ customCurrent(11)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Binary modes have two states represented by the values 0 (low) or 1
+ (high). These correspond to a2dSensorLowLabel and a2dSensorHighLabel.
+ Current and voltage modes provide a scaled value from a2dSensorMin to
+ a2dSensorMax.
+ Analog modes:
+ 1 = Door (binary)
+ 2 = Power failure (binary)
+ 3 = Flood (binary)
+ 4 = Water-sensing cable leak (binary)
+ 5 = Water-sensing cable fault (binary)
+ 6 = Smoke alarm (binary)
+ 7 = Isolated voltage negative ground (voltage)
+ 8 = Isolated voltage positive ground (voltage)
+ 9 = Custom voltage (voltage)
+ 10 = Custom binary (binary)
+ 11 = Custom current (current)"
+ ::= { a2dSensorEntry 7 }
+
+a2dSensorUnits OBJECT-TYPE
+ SYNTAX SnmpAdminString(SIZE (0..7))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The units for the analog value. If a2dSensorMode is customVoltage(9)
+ or customCurrent(11), then this field has a user-defined value.
+ Otherwise, the value is fixed, based on mode."
+ ::= { a2dSensorEntry 8 }
+
+a2dSensorMin OBJECT-TYPE
+ SYNTAX Integer32(-1000000..1000000)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Minimum analog value, given as an integer. The analog measurement is
+ scaled to the range a2dSensorMin to a2dSensorMax. If a2dSensorMode is
+ customVoltage(9) or customCurrent(11), then this field has a user-
+ defined value. Otherwise, the value is fixed, based on mode."
+ ::= { a2dSensorEntry 9 }
+
+a2dSensorMax OBJECT-TYPE
+ SYNTAX Integer32(-1000000..1000000)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Maximum analog value, given as an integer. The analog measurement is
+ scaled to the range a2dSensorMin to a2dSensorMax. If a2dSensorMode is
+ customVoltage(9) or customCurrent(11), then this field has a user-
+ defined value. Otherwise, the value is fixed, based on mode."
+ ::= { a2dSensorEntry 10 }
+
+a2dSensorLowLabel OBJECT-TYPE
+ SYNTAX SnmpAdminString(SIZE (0..25))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Label for 0 (low) binary value. This field is only applicable if
+ a2dSensorMode is one of the binary modes. If a2dSensorMode is
+ customBinary(10), then this field is user-defined. Otherwise, it has a
+ pre-defined value based on the mode."
+ ::= { a2dSensorEntry 11 }
+
+a2dSensorHighLabel OBJECT-TYPE
+ SYNTAX SnmpAdminString(SIZE (0..25))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Label for 1 (high) binary value. The field is only applicable if
+ a2dSensorMode is one of the binary modes. If a2dSensorMode is
+ customBinary(10), then this field is user-defined. Otherwise, it has a
+ pre-defined value based on the mode."
+ ::= { a2dSensorEntry 12 }
+
+a2dSensorAnalogLabel OBJECT-TYPE
+ SYNTAX SnmpAdminString(SIZE (0..25))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Label for the analog measurement"
+ ::= { a2dSensorEntry 13 }
+
+--###########################################################################################--
+--humiditySensorTable--
+--###########################################################################################--
+
+humiditySensorTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF HumiditySensorEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Remote humidity sensor"
+ ::= { imd 12 }
+
+humiditySensorEntry OBJECT-TYPE
+ SYNTAX HumiditySensorEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry in the humiditySensorTable table: each entry contains an index
+ and other sensor details"
+ INDEX { humiditySensorIndex }
+ ::= { humiditySensorTable 1 }
+
+HumiditySensorEntry ::= SEQUENCE {
+ humiditySensorIndex Integer32,
+ humiditySensorSerial DisplayString,
+ humiditySensorLabel SnmpAdminString,
+ humiditySensorAvail Gauge32,
+ humiditySensorValue Integer32
+}
+
+humiditySensorIndex OBJECT-TYPE
+ SYNTAX Integer32(1..100)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table entry index value"
+ ::= { humiditySensorEntry 1 }
+
+humiditySensorSerial OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Serial number"
+ ::= { humiditySensorEntry 2 }
+
+humiditySensorLabel OBJECT-TYPE
+ SYNTAX SnmpAdminString(SIZE (0..25))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "User-defined label"
+ ::= { humiditySensorEntry 3 }
+
+humiditySensorAvail OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Device availability:
+ 0 = Unavailable
+ 1 = Available
+ 2 = Partially Unavailable"
+ ::= { humiditySensorEntry 4 }
+
+humiditySensorValue OBJECT-TYPE
+ SYNTAX Integer32(0..100)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Humidity value"
+ ::= { humiditySensorEntry 5 }
+
+--###########################################################################################--
+--sn2dSensorTable--
+--###########################################################################################--
+
+sn2dSensorTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Sn2dSensorEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "2 Door Switch Sensor (SN-2D)"
+ ::= { imd 13 }
+
+sn2dSensorEntry OBJECT-TYPE
+ SYNTAX Sn2dSensorEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry in the sn2dSensorTable table: each entry contains an index
+ and other sensor details"
+ INDEX { sn2dSensorIndex }
+ ::= { sn2dSensorTable 1 }
+
+Sn2dSensorEntry ::= SEQUENCE {
+ sn2dSensorIndex Integer32,
+ sn2dSensorSerial DisplayString,
+ sn2dSensorLabel SnmpAdminString,
+ sn2dSensorAvail Gauge32,
+ sn2dSensorDoor1Label SnmpAdminString,
+ sn2dSensorDoor1State INTEGER,
+ sn2dSensorDoor1DisplayState SnmpAdminString,
+ sn2dSensorDoor2Label SnmpAdminString,
+ sn2dSensorDoor2State INTEGER,
+ sn2dSensorDoor2DisplayState SnmpAdminString
+}
+
+sn2dSensorIndex OBJECT-TYPE
+ SYNTAX Integer32(1..100)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table entry index value"
+ ::= { sn2dSensorEntry 1 }
+
+sn2dSensorSerial OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Serial number"
+ ::= { sn2dSensorEntry 2 }
+
+sn2dSensorLabel OBJECT-TYPE
+ SYNTAX SnmpAdminString(SIZE (0..25))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "User-defined label"
+ ::= { sn2dSensorEntry 3 }
+
+sn2dSensorAvail OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Device availability:
+ 0 = Unavailable
+ 1 = Available
+ 2 = Partially Unavailable"
+ ::= { sn2dSensorEntry 4 }
+
+sn2dSensorDoor1Label OBJECT-TYPE
+ SYNTAX SnmpAdminString(SIZE (0..25))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Door switch 1 label"
+ ::= { sn2dSensorEntry 5 }
+
+sn2dSensorDoor1State OBJECT-TYPE
+ SYNTAX INTEGER {
+ open(1),
+ closed(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Door switch 1 state:
+ 1 = open
+ 2 = closed"
+ ::= { sn2dSensorEntry 6 }
+
+sn2dSensorDoor1DisplayState OBJECT-TYPE
+ SYNTAX SnmpAdminString(SIZE (0..25))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Door switch 1 state given as a string"
+ ::= { sn2dSensorEntry 7 }
+
+sn2dSensorDoor2Label OBJECT-TYPE
+ SYNTAX SnmpAdminString(SIZE (0..25))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Door switch 2 label"
+ ::= { sn2dSensorEntry 8 }
+
+sn2dSensorDoor2State OBJECT-TYPE
+ SYNTAX INTEGER {
+ open(1),
+ closed(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Door switch 2 state:
+ 1 = open
+ 2 = closed"
+ ::= { sn2dSensorEntry 9 }
+
+sn2dSensorDoor2DisplayState OBJECT-TYPE
+ SYNTAX SnmpAdminString(SIZE (0..25))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Door switch 2 state given as a string"
+ ::= { sn2dSensorEntry 10 }
+
+--###########################################################################################--
+--cooling--
+--###########################################################################################--
+
+cooling OBJECT IDENTIFIER ::= { imd 30 }
+
+--###########################################################################################--
+--vrc--
+--###########################################################################################--
+
+vrc OBJECT IDENTIFIER ::= { cooling 1 }
+
+--###########################################################################################--
+--vrcMainTable--
+--###########################################################################################--
+
+vrcMainTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF VrcMainEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table that contains general VRC information"
+ ::= { vrc 1 }
+
+vrcMainEntry OBJECT-TYPE
+ SYNTAX VrcMainEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry in the vrcMainTable: each entry represents a VRC device"
+ INDEX { vrcMainIndex }
+ ::= { vrcMainTable 1 }
+
+VrcMainEntry ::= SEQUENCE {
+ vrcMainIndex Integer32,
+ vrcMainSerial DisplayString,
+ vrcMainName SnmpAdminString,
+ vrcMainLabel SnmpAdminString,
+ vrcMainAvail Gauge32
+}
+
+vrcMainIndex OBJECT-TYPE
+ SYNTAX Integer32(1..100)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Unique id for each entry in the table"
+ ::= { vrcMainEntry 1 }
+
+vrcMainSerial OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Serial number"
+ ::= { vrcMainEntry 2 }
+
+vrcMainName OBJECT-TYPE
+ SYNTAX SnmpAdminString(SIZE (1..25))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "VRC name (factory-assigned)"
+ ::= { vrcMainEntry 3 }
+
+vrcMainLabel OBJECT-TYPE
+ SYNTAX SnmpAdminString(SIZE (0..25))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "VRC label (user-defined)"
+ ::= { vrcMainEntry 4 }
+
+vrcMainAvail OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Device availability:
+ 0 = Unavailable
+ 1 = Available
+ 2 = Partially Unavailable"
+ ::= { vrcMainEntry 5 }
+
+--###########################################################################################--
+--vrcMainPtTable--
+--###########################################################################################--
+
+vrcMainPtTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF VrcMainPtEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table that contains general VRC status"
+ ::= { vrc 2 }
+
+vrcMainPtEntry OBJECT-TYPE
+ SYNTAX VrcMainPtEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry in the vrcMainPtTable: each entry contains status data for a VRC
+ device"
+ INDEX { vrcMainPtIndex }
+ ::= { vrcMainPtTable 1 }
+
+VrcMainPtEntry ::= SEQUENCE {
+ vrcMainPtIndex Integer32,
+ vrcMainPtRunState INTEGER,
+ vrcMainPtEevOpened Integer32,
+ vrcMainPtAlarmNumbers Integer32,
+ vrcMainPtHistoryAlarmNumbers Integer32,
+ vrcMainPtHpAbnRecordCnt Integer32,
+ vrcMainPtMonitorBaudrate INTEGER,
+ vrcMainPtMonitorAddress Integer32,
+ vrcMainPtLp TruthValue,
+ vrcMainPtFilterMaintRemind TruthValue,
+ vrcMainPtCoolingFlag TruthValue,
+ vrcMainPtFirstOnFlag TruthValue,
+ vrcMainPtNewAlarmFlag TruthValue,
+ vrcMainPtComAlarmOutState TruthValue,
+ vrcMainPtHighWaterInput TruthValue,
+ vrcMainPtHighWaterAlarm TruthValue,
+ vrcMainPtWaterUnderFloorAlarm TruthValue,
+ vrcMainPtSwShutDownStatus TruthValue,
+ vrcMainPtRemoteShutdown TruthValue,
+ vrcMainPtRemoteShutDownFlag TruthValue,
+ vrcMainPtRemoteShutDownAlarm TruthValue,
+ vrcMainPtHmiShutDownFlag TruthValue,
+ vrcMainPtLpAlarm TruthValue,
+ vrcMainPtHpAlarm TruthValue,
+ vrcMainPtLpFreqAlarm TruthValue,
+ vrcMainPtHpFreqAlarm TruthValue,
+ vrcMainPtLpSensorFailAlarm TruthValue,
+ vrcMainPtHpSensorFailAlarm TruthValue,
+ vrcMainPtEevCommFailAlarm TruthValue
+}
+
+vrcMainPtIndex OBJECT-TYPE
+ SYNTAX Integer32(1..100)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Unique id for each entry in the table"
+ ::= { vrcMainPtEntry 1 }
+
+vrcMainPtRunState OBJECT-TYPE
+ SYNTAX INTEGER {
+ on(1),
+ off(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "VRC run state:
+ 1 = on
+ 2 = off"
+ ::= { vrcMainPtEntry 2 }
+
+vrcMainPtEevOpened OBJECT-TYPE
+ SYNTAX Integer32(0..100)
+ UNITS "%"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Eev opened value (percent)"
+ ::= { vrcMainPtEntry 3 }
+
+vrcMainPtAlarmNumbers OBJECT-TYPE
+ SYNTAX Integer32(-32768..32767)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Alarm numbers value"
+ ::= { vrcMainPtEntry 4 }
+
+vrcMainPtHistoryAlarmNumbers OBJECT-TYPE
+ SYNTAX Integer32(-32768..32767)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "History alarm numbers value"
+ ::= { vrcMainPtEntry 5 }
+
+vrcMainPtHpAbnRecordCnt OBJECT-TYPE
+ SYNTAX Integer32(-32768..32767)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Hp Abnormal record count"
+ ::= { vrcMainPtEntry 6 }
+
+vrcMainPtMonitorBaudrate OBJECT-TYPE
+ SYNTAX INTEGER {
+ error(1),
+ baud1200(2),
+ baud2400(3),
+ baud4800(4),
+ baud9600(5),
+ baud19200(6)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Monitor baud rate:
+ 1 = error
+ 2 = 1200
+ 3 = 2400
+ 4 = 4800
+ 5 = 9600
+ 6 = 19200"
+ ::= { vrcMainPtEntry 7 }
+
+vrcMainPtMonitorAddress OBJECT-TYPE
+ SYNTAX Integer32(1..247)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Monitor address"
+ ::= { vrcMainPtEntry 8 }
+
+vrcMainPtLp OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Lp status"
+ ::= { vrcMainPtEntry 9 }
+
+vrcMainPtFilterMaintRemind OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Filter maintenance reminder status"
+ ::= { vrcMainPtEntry 10 }
+
+vrcMainPtCoolingFlag OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cooling flag"
+ ::= { vrcMainPtEntry 11 }
+
+vrcMainPtFirstOnFlag OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "First on flag"
+ ::= { vrcMainPtEntry 12 }
+
+vrcMainPtNewAlarmFlag OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "New alarm flag"
+ ::= { vrcMainPtEntry 13 }
+
+vrcMainPtComAlarmOutState OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Common alarm output state"
+ ::= { vrcMainPtEntry 14 }
+
+vrcMainPtHighWaterInput OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "High water input"
+ ::= { vrcMainPtEntry 15 }
+
+vrcMainPtHighWaterAlarm OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "High water alarm status"
+ ::= { vrcMainPtEntry 16 }
+
+vrcMainPtWaterUnderFloorAlarm OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Water under floor alarm status"
+ ::= { vrcMainPtEntry 17 }
+
+vrcMainPtSwShutDownStatus OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Software shutdown status"
+ ::= { vrcMainPtEntry 18 }
+
+vrcMainPtRemoteShutdown OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Remote shutdown status"
+ ::= { vrcMainPtEntry 19 }
+
+vrcMainPtRemoteShutDownFlag OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Remote shutdown flag"
+ ::= { vrcMainPtEntry 20 }
+
+vrcMainPtRemoteShutDownAlarm OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Remote shutdown alarm status"
+ ::= { vrcMainPtEntry 21 }
+
+vrcMainPtHmiShutDownFlag OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Hmi shutdown flag"
+ ::= { vrcMainPtEntry 22 }
+
+vrcMainPtLpAlarm OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Low pressure alarm status"
+ ::= { vrcMainPtEntry 23 }
+
+vrcMainPtHpAlarm OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "High pressure alarm status"
+ ::= { vrcMainPtEntry 24 }
+
+vrcMainPtLpFreqAlarm OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Low pressure frequently alarm status"
+ ::= { vrcMainPtEntry 25 }
+
+vrcMainPtHpFreqAlarm OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "High pressure frequently alarm status"
+ ::= { vrcMainPtEntry 26 }
+
+vrcMainPtLpSensorFailAlarm OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Low pressure sensor failure alarm status"
+ ::= { vrcMainPtEntry 27 }
+
+vrcMainPtHpSensorFailAlarm OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "High pressure sensor failure alarm status"
+ ::= { vrcMainPtEntry 28 }
+
+vrcMainPtEevCommFailAlarm OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Eev communication failure alarm status"
+ ::= { vrcMainPtEntry 29 }
+
+--###########################################################################################--
+--vrcMainCfgTable--
+--###########################################################################################--
+
+vrcMainCfgTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF VrcMainCfgEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table that contains general VRC configuration"
+ ::= { vrc 3 }
+
+vrcMainCfgEntry OBJECT-TYPE
+ SYNTAX VrcMainCfgEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry in the vrcMainCfgTable: each entry contains general config
+ fields for a VRC device"
+ INDEX { vrcMainCfgIndex }
+ ::= { vrcMainCfgTable 1 }
+
+VrcMainCfgEntry ::= SEQUENCE {
+ vrcMainCfgIndex Integer32,
+ vrcMainCfgModelSelect INTEGER,
+ vrcMainCfgSystemTimeYear Integer32,
+ vrcMainCfgSystemTimeMonth Integer32,
+ vrcMainCfgSystemTimeDay Integer32,
+ vrcMainCfgSystemTimeHour Integer32,
+ vrcMainCfgSystemTimeMin Integer32,
+ vrcMainCfgSystemTimeSec Integer32,
+ vrcMainCfgEevShtSettingMin Integer32,
+ vrcMainCfgEevShtSettingMax Integer32,
+ vrcMainCfgEevValveCloseSht Integer32,
+ vrcMainCfgEevMopPressSetting Integer32,
+ vrcMainCfgLpdt Integer32,
+ vrcMainCfgDeadBand Integer32,
+ vrcMainCfgOnOffSwitch TruthValue,
+ vrcMainCfgVacuumState TruthValue,
+ vrcMainCfgControlMode INTEGER,
+ vrcMainCfgManualRunEnable TruthValue,
+ vrcMainCfgRemShutdownInput TruthValue,
+ vrcMainCfgMonitorShutDownFlag TruthValue,
+ vrcMainCfgFirstOnPassword Integer32,
+ vrcMainCfgFilterMaintSetting TruthValue,
+ vrcMainCfgFilterMaintRemindTime Integer32,
+ vrcMainCfgFilterMaintRemindCtrl INTEGER,
+ vrcMainCfgCommonAlarmOutputDir TruthValue,
+ vrcMainCfgHpAbnAlarmSetting Integer32,
+ vrcMainCfgLpAlarmCtrl INTEGER,
+ vrcMainCfgHpAlarmCtrl INTEGER,
+ vrcMainCfgLpFreqAlarmCtrl INTEGER,
+ vrcMainCfgHpFreqAlarmCtrl INTEGER,
+ vrcMainCfgLpSensorFailAlarmCtrl INTEGER,
+ vrcMainCfgHpSensorFailAlarmCtrl INTEGER,
+ vrcMainCfgHighWaterAlarmCtrl INTEGER,
+ vrcMainCfgRemShutdownAlarmCtrl INTEGER,
+ vrcMainCfgEevCommFailAlarmCtrl INTEGER
+}
+
+vrcMainCfgIndex OBJECT-TYPE
+ SYNTAX Integer32(1..100)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Unique id for each entry in the table"
+ ::= { vrcMainCfgEntry 1 }
+
+vrcMainCfgModelSelect OBJECT-TYPE
+ SYNTAX INTEGER {
+ tmLoc(1),
+ r035Ap(2),
+ r035Ak(3),
+ scLoc(4),
+ zeroULoc(5),
+ r035Ep(6),
+ r035Ek(7)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Model Selection:
+ 1 = TMM-Local 220V 50/60HZ
+ 2 = TMM-Global 208/230V 50/60HZ
+ 3 = TMM-Global 120V 50/60HZ
+ 4 = SC 220V 50/60HZ
+ 5 = 0U 220V 50/60HZ
+ 6 = SS 208/230V 50/60HZ
+ 7 = SS 120V 50/60HZ"
+ ::= { vrcMainCfgEntry 2 }
+
+vrcMainCfgSystemTimeYear OBJECT-TYPE
+ SYNTAX Integer32(2000..2099)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "System time - year"
+ ::= { vrcMainCfgEntry 3 }
+
+vrcMainCfgSystemTimeMonth OBJECT-TYPE
+ SYNTAX Integer32(1..12)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "System time - month"
+ ::= { vrcMainCfgEntry 4 }
+
+vrcMainCfgSystemTimeDay OBJECT-TYPE
+ SYNTAX Integer32(1..31)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "System time - day"
+ ::= { vrcMainCfgEntry 5 }
+
+vrcMainCfgSystemTimeHour OBJECT-TYPE
+ SYNTAX Integer32(0..23)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "System time - hour"
+ ::= { vrcMainCfgEntry 6 }
+
+vrcMainCfgSystemTimeMin OBJECT-TYPE
+ SYNTAX Integer32(0..59)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "System time - minutes"
+ ::= { vrcMainCfgEntry 7 }
+
+vrcMainCfgSystemTimeSec OBJECT-TYPE
+ SYNTAX Integer32(0..59)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "System time - seconds"
+ ::= { vrcMainCfgEntry 8 }
+
+vrcMainCfgEevShtSettingMin OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "decidegrees"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Min Eev sht in tenths of a degree. Units are given by temperatureUnits
+ field in deviceInfo. The settable range is determined by the current
+ temperature units.
+ Celsius: 50 to 200
+ Fahrenheit: 90 to 359"
+ ::= { vrcMainCfgEntry 9 }
+
+vrcMainCfgEevShtSettingMax OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "decidegrees"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Max Eev sht in tenths of a degree. Units are given by temperatureUnits
+ field in deviceInfo. The settable range is determined by the current
+ temperature units.
+ Celsius: 50 to 200
+ Fahrenheit: 90 to 359"
+ ::= { vrcMainCfgEntry 10 }
+
+vrcMainCfgEevValveCloseSht OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "decidegrees"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Eev valve close sht in tenths of a degree. Units are given by
+ temperatureUnits field in deviceInfo. The settable range is determined
+ by the current temperature units.
+ Celsius: 0 to 100
+ Fahrenheit: 0 to 179"
+ ::= { vrcMainCfgEntry 11 }
+
+vrcMainCfgEevMopPressSetting OBJECT-TYPE
+ SYNTAX Integer32(0..200)
+ UNITS "decibars"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Eev mop pressure setting in tenths of a bar."
+ ::= { vrcMainCfgEntry 12 }
+
+vrcMainCfgLpdt OBJECT-TYPE
+ SYNTAX Integer32(30..600)
+ UNITS "seconds"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low pressure dt in seconds"
+ ::= { vrcMainCfgEntry 13 }
+
+vrcMainCfgDeadBand OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "decidegrees"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Dead band in tenths of a degree. Units are given by temperatureUnits
+ field in deviceInfo. The settable range is determined by the current
+ temperature units.
+ Celsius: 0 to 20
+ Fahrenheit: 0 to 35"
+ ::= { vrcMainCfgEntry 14 }
+
+vrcMainCfgOnOffSwitch OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "On-off switch"
+ ::= { vrcMainCfgEntry 15 }
+
+vrcMainCfgVacuumState OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Vacuum state"
+ ::= { vrcMainCfgEntry 16 }
+
+vrcMainCfgControlMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ supply(1),
+ return(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Control mode:
+ 1 = supply
+ 2 = return"
+ ::= { vrcMainCfgEntry 17 }
+
+vrcMainCfgManualRunEnable OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Manual run enable"
+ ::= { vrcMainCfgEntry 18 }
+
+vrcMainCfgRemShutdownInput OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Remote shutdown input"
+ ::= { vrcMainCfgEntry 19 }
+
+vrcMainCfgMonitorShutDownFlag OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Monitor shutdown flag"
+ ::= { vrcMainCfgEntry 20 }
+
+vrcMainCfgFirstOnPassword OBJECT-TYPE
+ SYNTAX Integer32(-32768..32767)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "First on password value"
+ ::= { vrcMainCfgEntry 21 }
+
+vrcMainCfgFilterMaintSetting OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Filter maintenance setting"
+ ::= { vrcMainCfgEntry 22 }
+
+vrcMainCfgFilterMaintRemindTime OBJECT-TYPE
+ SYNTAX Integer32(30..360)
+ UNITS "days"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time between filter maintenance reminders in days"
+ ::= { vrcMainCfgEntry 23 }
+
+vrcMainCfgFilterMaintRemindCtrl OBJECT-TYPE
+ SYNTAX INTEGER {
+ close(1),
+ suspend(2),
+ open(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Filter maintenance reminder:
+ 1 = close
+ 2 = suspend
+ 3 = open"
+ ::= { vrcMainCfgEntry 24 }
+
+vrcMainCfgCommonAlarmOutputDir OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Common alarm output direction"
+ ::= { vrcMainCfgEntry 25 }
+
+vrcMainCfgHpAbnAlarmSetting OBJECT-TYPE
+ SYNTAX Integer32(300..360)
+ UNITS "decibars"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Abnormal high pressure alarm value in tenths of a bar"
+ ::= { vrcMainCfgEntry 26 }
+
+vrcMainCfgLpAlarmCtrl OBJECT-TYPE
+ SYNTAX INTEGER {
+ suspend(2),
+ open(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low pressure alarm control:
+ 2 = suspend
+ 3 = open"
+ ::= { vrcMainCfgEntry 27 }
+
+vrcMainCfgHpAlarmCtrl OBJECT-TYPE
+ SYNTAX INTEGER {
+ suspend(2),
+ open(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High pressure alarm control:
+ 2 = suspend
+ 3 = open"
+ ::= { vrcMainCfgEntry 28 }
+
+vrcMainCfgLpFreqAlarmCtrl OBJECT-TYPE
+ SYNTAX INTEGER {
+ suspend(2),
+ open(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low pressure frequently alarm control:
+ 2 = suspend
+ 3 = open"
+ ::= { vrcMainCfgEntry 29 }
+
+vrcMainCfgHpFreqAlarmCtrl OBJECT-TYPE
+ SYNTAX INTEGER {
+ suspend(2),
+ open(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High pressure frequently alarm control:
+ 2 = suspend
+ 3 = open"
+ ::= { vrcMainCfgEntry 30 }
+
+vrcMainCfgLpSensorFailAlarmCtrl OBJECT-TYPE
+ SYNTAX INTEGER {
+ suspend(2),
+ open(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low pressure sensor failure alarm control:
+ 2 = suspend
+ 3 = open"
+ ::= { vrcMainCfgEntry 31 }
+
+vrcMainCfgHpSensorFailAlarmCtrl OBJECT-TYPE
+ SYNTAX INTEGER {
+ suspend(2),
+ open(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High pressure sensor failure alarm control:
+ 2 = suspend
+ 3 = open"
+ ::= { vrcMainCfgEntry 32 }
+
+vrcMainCfgHighWaterAlarmCtrl OBJECT-TYPE
+ SYNTAX INTEGER {
+ close(1),
+ suspend(2),
+ open(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High water alarm control:
+ 1 = close
+ 2 = suspend
+ 3 = open"
+ ::= { vrcMainCfgEntry 33 }
+
+vrcMainCfgRemShutdownAlarmCtrl OBJECT-TYPE
+ SYNTAX INTEGER {
+ suspend(2),
+ open(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Remote shutdown alarm control:
+ 2 = suspend
+ 3 = open"
+ ::= { vrcMainCfgEntry 34 }
+
+vrcMainCfgEevCommFailAlarmCtrl OBJECT-TYPE
+ SYNTAX INTEGER {
+ suspend(2),
+ open(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Eev communication failure alarm:
+ 2 = suspend
+ 3 = open"
+ ::= { vrcMainCfgEntry 35 }
+
+--###########################################################################################--
+--vrcOutFanPtTable--
+--###########################################################################################--
+
+vrcOutFanPtTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF VrcOutFanPtEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table that contains VRC out-fan status"
+ ::= { vrc 4 }
+
+vrcOutFanPtEntry OBJECT-TYPE
+ SYNTAX VrcOutFanPtEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry in the vrcOutFanPtTable: each entry represents data for a VRC
+ out-fan"
+ INDEX { vrcOutFanPtIndex }
+ ::= { vrcOutFanPtTable 1 }
+
+VrcOutFanPtEntry ::= SEQUENCE {
+ vrcOutFanPtIndex Integer32,
+ vrcOutFanPtName SnmpAdminString,
+ vrcOutFanPtSpeed Integer32
+}
+
+vrcOutFanPtIndex OBJECT-TYPE
+ SYNTAX Integer32(1..100)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Unique id for each entry in the table"
+ ::= { vrcOutFanPtEntry 1 }
+
+vrcOutFanPtName OBJECT-TYPE
+ SYNTAX SnmpAdminString(SIZE (1..25))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Out-fan name (factory-assigned)"
+ ::= { vrcOutFanPtEntry 2 }
+
+vrcOutFanPtSpeed OBJECT-TYPE
+ SYNTAX Integer32(0..100)
+ UNITS "%"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Fan speed (percent)"
+ ::= { vrcOutFanPtEntry 3 }
+
+--###########################################################################################--
+--vrcOutFanCfgTable--
+--###########################################################################################--
+
+vrcOutFanCfgTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF VrcOutFanCfgEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table used for VRC out-fan configuration"
+ ::= { vrc 5 }
+
+vrcOutFanCfgEntry OBJECT-TYPE
+ SYNTAX VrcOutFanCfgEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry in the vrcOutFanCfgTable: each entry contains config fields for
+ a VRC out-fan"
+ INDEX { vrcOutFanCfgIndex }
+ ::= { vrcOutFanCfgTable 1 }
+
+VrcOutFanCfgEntry ::= SEQUENCE {
+ vrcOutFanCfgIndex Integer32,
+ vrcOutFanCfgStartPress Integer32,
+ vrcOutFanCfgPressSetting Integer32,
+ vrcOutFanCfgMinPowerVoltage Integer32,
+ vrcOutFanCfgMaxPowerVoltage Integer32,
+ vrcOutFanCfgSpeed Integer32
+}
+
+vrcOutFanCfgIndex OBJECT-TYPE
+ SYNTAX Integer32(1..100)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Unique id for each entry in the table"
+ ::= { vrcOutFanCfgEntry 1 }
+
+vrcOutFanCfgStartPress OBJECT-TYPE
+ SYNTAX Integer32(190..250)
+ UNITS "decibars"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Out-fan start pressure in tenths of a bar"
+ ::= { vrcOutFanCfgEntry 2 }
+
+vrcOutFanCfgPressSetting OBJECT-TYPE
+ SYNTAX Integer32(50..80)
+ UNITS "decibars"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Out-fan pressure setting in tenths of a bar"
+ ::= { vrcOutFanCfgEntry 3 }
+
+vrcOutFanCfgMinPowerVoltage OBJECT-TYPE
+ SYNTAX Integer32(30..50)
+ UNITS "%"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Min out-fan voltage (percent)"
+ ::= { vrcOutFanCfgEntry 4 }
+
+vrcOutFanCfgMaxPowerVoltage OBJECT-TYPE
+ SYNTAX Integer32(60..100)
+ UNITS "%"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Max out-fan voltage (percent)"
+ ::= { vrcOutFanCfgEntry 5 }
+
+vrcOutFanCfgSpeed OBJECT-TYPE
+ SYNTAX Integer32(0..100)
+ UNITS "%"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Out-fan speed (percent)"
+ ::= { vrcOutFanCfgEntry 6 }
+
+--###########################################################################################--
+--vrcInFanPtTable--
+--###########################################################################################--
+
+vrcInFanPtTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF VrcInFanPtEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table that contains VRC in-fan status"
+ ::= { vrc 6 }
+
+vrcInFanPtEntry OBJECT-TYPE
+ SYNTAX VrcInFanPtEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry in the vrcInFanPtTable: each entry represents data for a VRC in-
+ fan"
+ INDEX { vrcInFanPtIndex }
+ ::= { vrcInFanPtTable 1 }
+
+VrcInFanPtEntry ::= SEQUENCE {
+ vrcInFanPtIndex Integer32,
+ vrcInFanPtName SnmpAdminString,
+ vrcInFanPtRunTimeHours Integer32,
+ vrcInFanPtStartStopCount Integer32
+}
+
+vrcInFanPtIndex OBJECT-TYPE
+ SYNTAX Integer32(1..100)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Unique id for each entry in the table"
+ ::= { vrcInFanPtEntry 1 }
+
+vrcInFanPtName OBJECT-TYPE
+ SYNTAX SnmpAdminString(SIZE (1..25))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "In-fan name (factory-assigned)"
+ ::= { vrcInFanPtEntry 2 }
+
+vrcInFanPtRunTimeHours OBJECT-TYPE
+ SYNTAX Integer32(-32768..32767)
+ UNITS "hours"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "In-fan run time in hours"
+ ::= { vrcInFanPtEntry 3 }
+
+vrcInFanPtStartStopCount OBJECT-TYPE
+ SYNTAX Integer32(-32768..32767)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "In-fan start/stop count"
+ ::= { vrcInFanPtEntry 4 }
+
+--###########################################################################################--
+--vrcInFanCfgTable--
+--###########################################################################################--
+
+vrcInFanCfgTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF VrcInFanCfgEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table used for VRC in-fan configuration"
+ ::= { vrc 7 }
+
+vrcInFanCfgEntry OBJECT-TYPE
+ SYNTAX VrcInFanCfgEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry in the vrcInFanCfgTable: each entry contains config fields for a
+ VRC in-fan"
+ INDEX { vrcInFanCfgIndex }
+ ::= { vrcInFanCfgTable 1 }
+
+VrcInFanCfgEntry ::= SEQUENCE {
+ vrcInFanCfgIndex Integer32,
+ vrcInFanCfgOutputStatus TruthValue,
+ vrcInFanCfgLowSpeedStep Integer32,
+ vrcInFanCfgHighSpeedStep Integer32,
+ vrcInFanCfgMinSpeed Integer32,
+ vrcInFanCfgStandardSpeed Integer32,
+ vrcInFanCfgMinCfc Integer32,
+ vrcInFanCfgStandardCfc Integer32,
+ vrcInFanCfgStartDelay Integer32,
+ vrcInFanCfgStopDelay Integer32,
+ vrcInFanCfgReduceSpeedDelay Integer32,
+ vrcInFanCfgJumpBand1 Integer32,
+ vrcInFanCfgJumpBand2 Integer32,
+ vrcInFanCfgJumpBand3 Integer32,
+ vrcInFanCfgJumpBand4 Integer32,
+ vrcInFanCfgJumpBand5 Integer32,
+ vrcInFanCfgJumpFreq1 Integer32,
+ vrcInFanCfgJumpFreq2 Integer32,
+ vrcInFanCfgJumpFreq3 Integer32,
+ vrcInFanCfgJumpFreq4 Integer32,
+ vrcInFanCfgJumpFreq5 Integer32,
+ vrcInFanCfgTempP Integer32,
+ vrcInFanCfgTempI Integer32,
+ vrcInFanCfgTempD Integer32
+}
+
+vrcInFanCfgIndex OBJECT-TYPE
+ SYNTAX Integer32(1..100)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Unique id for each entry in the table"
+ ::= { vrcInFanCfgEntry 1 }
+
+vrcInFanCfgOutputStatus OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "In-fan output status"
+ ::= { vrcInFanCfgEntry 2 }
+
+vrcInFanCfgLowSpeedStep OBJECT-TYPE
+ SYNTAX Integer32(1..20)
+ UNITS "0.1%/s"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "In-fan low speed step in tenths of a percent per second"
+ ::= { vrcInFanCfgEntry 3 }
+
+vrcInFanCfgHighSpeedStep OBJECT-TYPE
+ SYNTAX Integer32(1..50)
+ UNITS "0.1%/s"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "In-fan high speed step in tenths of a percent per second"
+ ::= { vrcInFanCfgEntry 4 }
+
+vrcInFanCfgMinSpeed OBJECT-TYPE
+ SYNTAX Integer32(30..80)
+ UNITS "%"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Min in-fan speed (percent)"
+ ::= { vrcInFanCfgEntry 5 }
+
+vrcInFanCfgStandardSpeed OBJECT-TYPE
+ SYNTAX Integer32(80..100)
+ UNITS "%"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Standard in-fan speed (percent)"
+ ::= { vrcInFanCfgEntry 6 }
+
+vrcInFanCfgMinCfc OBJECT-TYPE
+ SYNTAX Integer32(0..30)
+ UNITS "%"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Min in-fan cfc (percent)"
+ ::= { vrcInFanCfgEntry 7 }
+
+vrcInFanCfgStandardCfc OBJECT-TYPE
+ SYNTAX Integer32(85..100)
+ UNITS "%"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Standard in-fan cfc (percent)"
+ ::= { vrcInFanCfgEntry 8 }
+
+vrcInFanCfgStartDelay OBJECT-TYPE
+ SYNTAX Integer32(10..600)
+ UNITS "seconds"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "In-fan start delay in seconds"
+ ::= { vrcInFanCfgEntry 9 }
+
+vrcInFanCfgStopDelay OBJECT-TYPE
+ SYNTAX Integer32(10..300)
+ UNITS "seconds"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "In-fan stop delay in seconds"
+ ::= { vrcInFanCfgEntry 10 }
+
+vrcInFanCfgReduceSpeedDelay OBJECT-TYPE
+ SYNTAX Integer32(0..300)
+ UNITS "seconds"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "In-fan reduce speed delay in seconds"
+ ::= { vrcInFanCfgEntry 11 }
+
+vrcInFanCfgJumpBand1 OBJECT-TYPE
+ SYNTAX Integer32(0..100)
+ UNITS "0.1%"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "In-fan jump band 1 in tenths of a percent"
+ ::= { vrcInFanCfgEntry 12 }
+
+vrcInFanCfgJumpBand2 OBJECT-TYPE
+ SYNTAX Integer32(0..100)
+ UNITS "0.1%"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "In-fan jump band 2 in tenths of a percent"
+ ::= { vrcInFanCfgEntry 13 }
+
+vrcInFanCfgJumpBand3 OBJECT-TYPE
+ SYNTAX Integer32(0..100)
+ UNITS "0.1%"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "In-fan jump band 3 in tenths of a percent"
+ ::= { vrcInFanCfgEntry 14 }
+
+vrcInFanCfgJumpBand4 OBJECT-TYPE
+ SYNTAX Integer32(0..100)
+ UNITS "0.1%"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "In-fan jump band 4 in tenths of a percent"
+ ::= { vrcInFanCfgEntry 15 }
+
+vrcInFanCfgJumpBand5 OBJECT-TYPE
+ SYNTAX Integer32(0..100)
+ UNITS "0.1%"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "In-fan jump band 5 in tenths of a percent"
+ ::= { vrcInFanCfgEntry 16 }
+
+vrcInFanCfgJumpFreq1 OBJECT-TYPE
+ SYNTAX Integer32(0..1000)
+ UNITS "0.1%"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "In-fan jump frequency 1 in tenths of a percent"
+ ::= { vrcInFanCfgEntry 17 }
+
+vrcInFanCfgJumpFreq2 OBJECT-TYPE
+ SYNTAX Integer32(0..1000)
+ UNITS "0.1%"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "In-fan jump frequency 2 in tenths of a percent"
+ ::= { vrcInFanCfgEntry 18 }
+
+vrcInFanCfgJumpFreq3 OBJECT-TYPE
+ SYNTAX Integer32(0..1000)
+ UNITS "0.1%"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "In-fan jump frequency 3 in tenths of a percent"
+ ::= { vrcInFanCfgEntry 19 }
+
+vrcInFanCfgJumpFreq4 OBJECT-TYPE
+ SYNTAX Integer32(0..1000)
+ UNITS "0.1%"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "In-fan jump frequency 4 in tenths of a percent"
+ ::= { vrcInFanCfgEntry 20 }
+
+vrcInFanCfgJumpFreq5 OBJECT-TYPE
+ SYNTAX Integer32(0..1000)
+ UNITS "0.1%"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "In-fan jump frequency 5 in tenths of a percent"
+ ::= { vrcInFanCfgEntry 21 }
+
+vrcInFanCfgTempP OBJECT-TYPE
+ SYNTAX Integer32(10..150)
+ UNITS "decidegrees"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "In-fan temperature P in tenths of a degree. Units are given by
+ temperatureUnits field in deviceInfo."
+ ::= { vrcInFanCfgEntry 22 }
+
+vrcInFanCfgTempI OBJECT-TYPE
+ SYNTAX Integer32(0..900)
+ UNITS "seconds"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "In-fan temperature I in seconds"
+ ::= { vrcInFanCfgEntry 23 }
+
+vrcInFanCfgTempD OBJECT-TYPE
+ SYNTAX Integer32(0..900)
+ UNITS "seconds"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "In-fan temperature D in seconds"
+ ::= { vrcInFanCfgEntry 24 }
+
+--###########################################################################################--
+--vrcCompPtTable--
+--###########################################################################################--
+
+vrcCompPtTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF VrcCompPtEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table that contains VRC compressor status"
+ ::= { vrc 8 }
+
+vrcCompPtEntry OBJECT-TYPE
+ SYNTAX VrcCompPtEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry in the vrcCompPtTable: each entry represents data for a VRC
+ compressor"
+ INDEX { vrcCompPtIndex }
+ ::= { vrcCompPtTable 1 }
+
+VrcCompPtEntry ::= SEQUENCE {
+ vrcCompPtIndex Integer32,
+ vrcCompPtName SnmpAdminString,
+ vrcCompPtCapacity Integer32,
+ vrcCompPtRunTimeHours Integer32,
+ vrcCompPtStartStopCount Integer32,
+ vrcCompPtDriverFaultU00 TruthValue,
+ vrcCompPtDriverFaultU01 TruthValue,
+ vrcCompPtDriverFaultU02 TruthValue,
+ vrcCompPtDriverFaultU03 TruthValue,
+ vrcCompPtDriverFaultU04 TruthValue,
+ vrcCompPtDriverFaultU05 TruthValue,
+ vrcCompPtDriverFaultU06 TruthValue,
+ vrcCompPtDriverFaultU07 TruthValue,
+ vrcCompPtDriverFaultU08 TruthValue,
+ vrcCompPtDriverFaultU09 TruthValue,
+ vrcCompPtDriverFaultU10 TruthValue,
+ vrcCompPtDriverFaultU11 TruthValue,
+ vrcCompPtDriverFaultU12 TruthValue,
+ vrcCompPtDriverFaultU13 TruthValue,
+ vrcCompPtDriverFaultU14 TruthValue,
+ vrcCompPtDriverFaultU15 TruthValue,
+ vrcCompPtDriverCommFailAlarm TruthValue,
+ vrcCompPtFaultLockAlarm TruthValue
+}
+
+vrcCompPtIndex OBJECT-TYPE
+ SYNTAX Integer32(1..100)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Unique id for each entry in the table"
+ ::= { vrcCompPtEntry 1 }
+
+vrcCompPtName OBJECT-TYPE
+ SYNTAX SnmpAdminString(SIZE (1..25))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Compressor name (factory-assigned)"
+ ::= { vrcCompPtEntry 2 }
+
+vrcCompPtCapacity OBJECT-TYPE
+ SYNTAX Integer32(0..100)
+ UNITS "%"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Compressor capacity value (percent)"
+ ::= { vrcCompPtEntry 3 }
+
+vrcCompPtRunTimeHours OBJECT-TYPE
+ SYNTAX Integer32(-32768..32767)
+ UNITS "hours"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Compressor run time in hours"
+ ::= { vrcCompPtEntry 4 }
+
+vrcCompPtStartStopCount OBJECT-TYPE
+ SYNTAX Integer32(-32768..32767)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Compressor start/stop count"
+ ::= { vrcCompPtEntry 5 }
+
+vrcCompPtDriverFaultU00 OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Compressor driver fault alarm U00 state"
+ ::= { vrcCompPtEntry 6 }
+
+vrcCompPtDriverFaultU01 OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Compressor driver fault alarm U01 state"
+ ::= { vrcCompPtEntry 7 }
+
+vrcCompPtDriverFaultU02 OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Compressor driver fault alarm U02 state"
+ ::= { vrcCompPtEntry 8 }
+
+vrcCompPtDriverFaultU03 OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Compressor driver fault alarm U03 state"
+ ::= { vrcCompPtEntry 9 }
+
+vrcCompPtDriverFaultU04 OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Compressor driver fault alarm U04 state"
+ ::= { vrcCompPtEntry 10 }
+
+vrcCompPtDriverFaultU05 OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Compressor driver fault alarm U05 state"
+ ::= { vrcCompPtEntry 11 }
+
+vrcCompPtDriverFaultU06 OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Compressor driver fault alarm U06 state"
+ ::= { vrcCompPtEntry 12 }
+
+vrcCompPtDriverFaultU07 OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Compressor driver fault alarm U07 state"
+ ::= { vrcCompPtEntry 13 }
+
+vrcCompPtDriverFaultU08 OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Compressor driver fault alarm U08 state"
+ ::= { vrcCompPtEntry 14 }
+
+vrcCompPtDriverFaultU09 OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Compressor driver fault alarm U09 state"
+ ::= { vrcCompPtEntry 15 }
+
+vrcCompPtDriverFaultU10 OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Compressor driver fault alarm U10 state"
+ ::= { vrcCompPtEntry 16 }
+
+vrcCompPtDriverFaultU11 OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Compressor driver fault alarm U11 state"
+ ::= { vrcCompPtEntry 17 }
+
+vrcCompPtDriverFaultU12 OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Compressor driver fault alarm U12 state"
+ ::= { vrcCompPtEntry 18 }
+
+vrcCompPtDriverFaultU13 OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Compressor driver fault alarm U13 state"
+ ::= { vrcCompPtEntry 19 }
+
+vrcCompPtDriverFaultU14 OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Compressor driver fault alarm U14 state"
+ ::= { vrcCompPtEntry 20 }
+
+vrcCompPtDriverFaultU15 OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Compressor driver fault alarm U15 state"
+ ::= { vrcCompPtEntry 21 }
+
+vrcCompPtDriverCommFailAlarm OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Compressor driver communication failure alarm state"
+ ::= { vrcCompPtEntry 22 }
+
+vrcCompPtFaultLockAlarm OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Compressor fault lock alarm state"
+ ::= { vrcCompPtEntry 23 }
+
+--###########################################################################################--
+--vrcCompCfgTable--
+--###########################################################################################--
+
+vrcCompCfgTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF VrcCompCfgEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table used for VRC compressor configuration"
+ ::= { vrc 9 }
+
+vrcCompCfgEntry OBJECT-TYPE
+ SYNTAX VrcCompCfgEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry in the vrcCompCfgTable: each entry contains config fields for a
+ VRC compressor"
+ INDEX { vrcCompCfgIndex }
+ ::= { vrcCompCfgTable 1 }
+
+VrcCompCfgEntry ::= SEQUENCE {
+ vrcCompCfgIndex Integer32,
+ vrcCompCfgOutputStatus TruthValue,
+ vrcCompCfgOutputDeadBand Integer32,
+ vrcCompCfgCapacityOutputValue Integer32,
+ vrcCompCfgMinCapacity Integer32,
+ vrcCompCfgStartCapacity Integer32,
+ vrcCompCfgStandardCapacity Integer32,
+ vrcCompCfgStartCfc Integer32,
+ vrcCompCfgStopCfc Integer32,
+ vrcCompCfgMinRunTime Integer32,
+ vrcCompCfgMinStopTime Integer32,
+ vrcCompCfgJumpBand1 Integer32,
+ vrcCompCfgJumpBand2 Integer32,
+ vrcCompCfgJumpBand3 Integer32,
+ vrcCompCfgJumpBand4 Integer32,
+ vrcCompCfgJumpBand5 Integer32,
+ vrcCompCfgJumpFreq1 Integer32,
+ vrcCompCfgJumpFreq2 Integer32,
+ vrcCompCfgJumpFreq3 Integer32,
+ vrcCompCfgJumpFreq4 Integer32,
+ vrcCompCfgJumpFreq5 Integer32,
+ vrcCompCfgTempP Integer32,
+ vrcCompCfgTempI Integer32,
+ vrcCompCfgTempD Integer32,
+ vrcCompCfgDriverFaultAlmCtrl INTEGER,
+ vrcCompCfgDriverCommFailAlmCtrl INTEGER,
+ vrcCompCfgFaultLockAlmCtrl INTEGER
+}
+
+vrcCompCfgIndex OBJECT-TYPE
+ SYNTAX Integer32(1..100)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Unique id for each entry in the table"
+ ::= { vrcCompCfgEntry 1 }
+
+vrcCompCfgOutputStatus OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Compressor output status"
+ ::= { vrcCompCfgEntry 2 }
+
+vrcCompCfgOutputDeadBand OBJECT-TYPE
+ SYNTAX Integer32(0..50)
+ UNITS "0.1%"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Compressor output dead band in tenths of a percent"
+ ::= { vrcCompCfgEntry 3 }
+
+vrcCompCfgCapacityOutputValue OBJECT-TYPE
+ SYNTAX Integer32(0..100)
+ UNITS "%"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Compressor capacity output (percent)"
+ ::= { vrcCompCfgEntry 4 }
+
+vrcCompCfgMinCapacity OBJECT-TYPE
+ SYNTAX Integer32(15..50)
+ UNITS "%"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Compressor min capacity (percent)"
+ ::= { vrcCompCfgEntry 5 }
+
+vrcCompCfgStartCapacity OBJECT-TYPE
+ SYNTAX Integer32(40..100)
+ UNITS "%"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Compressor start capacity (percent)"
+ ::= { vrcCompCfgEntry 6 }
+
+vrcCompCfgStandardCapacity OBJECT-TYPE
+ SYNTAX Integer32(80..100)
+ UNITS "%"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Compressor standard capacity (percent)"
+ ::= { vrcCompCfgEntry 7 }
+
+vrcCompCfgStartCfc OBJECT-TYPE
+ SYNTAX Integer32(1..100)
+ UNITS "%"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Compressor start cfc (percent)"
+ ::= { vrcCompCfgEntry 8 }
+
+vrcCompCfgStopCfc OBJECT-TYPE
+ SYNTAX Integer32(-200..-50)
+ UNITS "%"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Compressor stop cfc (percent)"
+ ::= { vrcCompCfgEntry 9 }
+
+vrcCompCfgMinRunTime OBJECT-TYPE
+ SYNTAX Integer32(0..30)
+ UNITS "minutes"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Compressor min run time in minutes"
+ ::= { vrcCompCfgEntry 10 }
+
+vrcCompCfgMinStopTime OBJECT-TYPE
+ SYNTAX Integer32(0..10)
+ UNITS "minutes"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Compressor min stop time in minutes"
+ ::= { vrcCompCfgEntry 11 }
+
+vrcCompCfgJumpBand1 OBJECT-TYPE
+ SYNTAX Integer32(0..100)
+ UNITS "0.1%"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Compressor jump band 1 in tenths of a percent"
+ ::= { vrcCompCfgEntry 12 }
+
+vrcCompCfgJumpBand2 OBJECT-TYPE
+ SYNTAX Integer32(0..100)
+ UNITS "0.1%"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Compressor jump band 2 in tenths of a percent"
+ ::= { vrcCompCfgEntry 13 }
+
+vrcCompCfgJumpBand3 OBJECT-TYPE
+ SYNTAX Integer32(0..100)
+ UNITS "0.1%"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Compressor jump band 3 in tenths of a percent"
+ ::= { vrcCompCfgEntry 14 }
+
+vrcCompCfgJumpBand4 OBJECT-TYPE
+ SYNTAX Integer32(0..100)
+ UNITS "0.1%"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Compressor jump band 4 in tenths of a percent"
+ ::= { vrcCompCfgEntry 15 }
+
+vrcCompCfgJumpBand5 OBJECT-TYPE
+ SYNTAX Integer32(0..100)
+ UNITS "0.1%"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Compressor jump band 5 in tenths of a percent"
+ ::= { vrcCompCfgEntry 16 }
+
+vrcCompCfgJumpFreq1 OBJECT-TYPE
+ SYNTAX Integer32(0..1000)
+ UNITS "0.1%"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Compressor jump frequency 1 in tenths of a percent"
+ ::= { vrcCompCfgEntry 17 }
+
+vrcCompCfgJumpFreq2 OBJECT-TYPE
+ SYNTAX Integer32(0..1000)
+ UNITS "0.1%"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Compressor jump frequency 2 in tenths of a percent"
+ ::= { vrcCompCfgEntry 18 }
+
+vrcCompCfgJumpFreq3 OBJECT-TYPE
+ SYNTAX Integer32(0..1000)
+ UNITS "0.1%"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Compressor jump frequency 3 in tenths of a percent"
+ ::= { vrcCompCfgEntry 19 }
+
+vrcCompCfgJumpFreq4 OBJECT-TYPE
+ SYNTAX Integer32(0..1000)
+ UNITS "0.1%"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Compressor jump frequency 4 in tenths of a percent"
+ ::= { vrcCompCfgEntry 20 }
+
+vrcCompCfgJumpFreq5 OBJECT-TYPE
+ SYNTAX Integer32(0..1000)
+ UNITS "0.1%"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Compressor jump frequency 5 in tenths of a percent"
+ ::= { vrcCompCfgEntry 21 }
+
+vrcCompCfgTempP OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "decidegrees"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Compressor temperature P in tenths of a degree. Units are given by
+ temperatureUnits field in deviceInfo. The settable range is determined
+ by the current temperature units.
+ Celsius: 10 to 150
+ Fahrenheit: 18 to 269"
+ ::= { vrcCompCfgEntry 22 }
+
+vrcCompCfgTempI OBJECT-TYPE
+ SYNTAX Integer32(0..900)
+ UNITS "seconds"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Compressor temperature I in seconds"
+ ::= { vrcCompCfgEntry 23 }
+
+vrcCompCfgTempD OBJECT-TYPE
+ SYNTAX Integer32(0..900)
+ UNITS "seconds"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Compressor temperature D in seconds"
+ ::= { vrcCompCfgEntry 24 }
+
+vrcCompCfgDriverFaultAlmCtrl OBJECT-TYPE
+ SYNTAX INTEGER {
+ suspend(2),
+ open(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Compressor driver fault alarm control:
+ 2 = suspend
+ 3 = open"
+ ::= { vrcCompCfgEntry 25 }
+
+vrcCompCfgDriverCommFailAlmCtrl OBJECT-TYPE
+ SYNTAX INTEGER {
+ suspend(2),
+ open(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Compressor driver communication failure alarm control:
+ 2 = suspend
+ 3 = open"
+ ::= { vrcCompCfgEntry 26 }
+
+vrcCompCfgFaultLockAlmCtrl OBJECT-TYPE
+ SYNTAX INTEGER {
+ suspend(2),
+ open(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Compressor fault lock alarm control:
+ 2 = suspend
+ 3 = open"
+ ::= { vrcCompCfgEntry 27 }
+
+--###########################################################################################--
+--vrcReturnPtTable--
+--###########################################################################################--
+
+vrcReturnPtTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF VrcReturnPtEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table that contains VRC return status"
+ ::= { vrc 10 }
+
+vrcReturnPtEntry OBJECT-TYPE
+ SYNTAX VrcReturnPtEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry in the vrcReturnPtTable: each entry represents return data for a
+ VRC"
+ INDEX { vrcReturnPtIndex }
+ ::= { vrcReturnPtTable 1 }
+
+VrcReturnPtEntry ::= SEQUENCE {
+ vrcReturnPtIndex Integer32,
+ vrcReturnPtName SnmpAdminString,
+ vrcReturnPtTemp Integer32,
+ vrcReturnPtHighTempAlarm TruthValue,
+ vrcReturnPtTempSensorFailAlarm TruthValue
+}
+
+vrcReturnPtIndex OBJECT-TYPE
+ SYNTAX Integer32(1..100)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Unique id for each entry in the table"
+ ::= { vrcReturnPtEntry 1 }
+
+vrcReturnPtName OBJECT-TYPE
+ SYNTAX SnmpAdminString(SIZE (1..25))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Return name (factory-assigned)"
+ ::= { vrcReturnPtEntry 2 }
+
+vrcReturnPtTemp OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "decidegrees"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Return temperature value in tenths of a degree. Units are given by
+ temperatureUnits field in deviceInfo. The range is determined by the
+ current temperature units.
+ Celsius: -400 to 1000
+ Fahrenheit: -400 to 2120"
+ ::= { vrcReturnPtEntry 3 }
+
+vrcReturnPtHighTempAlarm OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Return high temperature alarm state"
+ ::= { vrcReturnPtEntry 4 }
+
+vrcReturnPtTempSensorFailAlarm OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Return temperature sensor failure alarm state"
+ ::= { vrcReturnPtEntry 5 }
+
+--###########################################################################################--
+--vrcReturnCfgTable--
+--###########################################################################################--
+
+vrcReturnCfgTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF VrcReturnCfgEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table used for VRC return configuration"
+ ::= { vrc 11 }
+
+vrcReturnCfgEntry OBJECT-TYPE
+ SYNTAX VrcReturnCfgEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry in the vrcReturnCfgTable: each entry contains config fields for
+ VRC return"
+ INDEX { vrcReturnCfgIndex }
+ ::= { vrcReturnCfgTable 1 }
+
+VrcReturnCfgEntry ::= SEQUENCE {
+ vrcReturnCfgIndex Integer32,
+ vrcReturnCfgOilCycle Integer32,
+ vrcReturnCfgOilRunCapacity Integer32,
+ vrcReturnCfgOilRunTime Integer32,
+ vrcReturnCfgTempCalValue Integer32,
+ vrcReturnCfgTempSetting Integer32,
+ vrcReturnCfgHighTempAlarmValue Integer32,
+ vrcReturnCfgHighTempAlarmCtrl INTEGER,
+ vrcReturnCfgTempSensFailAlmCtrl INTEGER
+}
+
+vrcReturnCfgIndex OBJECT-TYPE
+ SYNTAX Integer32(1..100)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Unique id for each entry in the table"
+ ::= { vrcReturnCfgEntry 1 }
+
+vrcReturnCfgOilCycle OBJECT-TYPE
+ SYNTAX Integer32(5..50)
+ UNITS "decihours"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return oil cycle in tenths of an hour"
+ ::= { vrcReturnCfgEntry 2 }
+
+vrcReturnCfgOilRunCapacity OBJECT-TYPE
+ SYNTAX Integer32(50..100)
+ UNITS "%"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return Oil run capacity (percent)"
+ ::= { vrcReturnCfgEntry 3 }
+
+vrcReturnCfgOilRunTime OBJECT-TYPE
+ SYNTAX Integer32(0..10)
+ UNITS "minutes"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return oil run time in minutes"
+ ::= { vrcReturnCfgEntry 4 }
+
+vrcReturnCfgTempCalValue OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "decidegrees"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return temperature calibration value in tenths of a degree. Units are
+ given by temperatureUnits field in deviceInfo. The settable range is
+ determined by the current temperature units.
+ Celsius: -100 to 100
+ Fahrenheit: -179 to 179"
+ ::= { vrcReturnCfgEntry 5 }
+
+vrcReturnCfgTempSetting OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "decidegrees"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return temperature setting in tenths of a degree. Units are given by
+ temperatureUnits field in deviceInfo. The settable range is determined
+ by the current temperature units.
+ Celsius: 250 to 350
+ Fahrenheit: 770 to 949"
+ ::= { vrcReturnCfgEntry 6 }
+
+vrcReturnCfgHighTempAlarmValue OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "decidegrees"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return high temperature alarm value in tenths of a degree. Units are
+ given by temperatureUnits field in deviceInfo. The settable range is
+ determined by the current temperature units.
+ Celsius: 300 to 450
+ Fahrenheit: 860 to 1129"
+ ::= { vrcReturnCfgEntry 7 }
+
+vrcReturnCfgHighTempAlarmCtrl OBJECT-TYPE
+ SYNTAX INTEGER {
+ close(1),
+ suspend(2),
+ open(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return high temperature alarm control:
+ 1 = close
+ 2 = suspend
+ 3 = open"
+ ::= { vrcReturnCfgEntry 8 }
+
+vrcReturnCfgTempSensFailAlmCtrl OBJECT-TYPE
+ SYNTAX INTEGER {
+ close(1),
+ suspend(2),
+ open(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return temperature sensor failure alarm control:
+ 1 = close
+ 2 = suspend
+ 3 = open"
+ ::= { vrcReturnCfgEntry 9 }
+
+--###########################################################################################--
+--vrcSupplyPtTable--
+--###########################################################################################--
+
+vrcSupplyPtTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF VrcSupplyPtEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table that contains VRC supply status"
+ ::= { vrc 12 }
+
+vrcSupplyPtEntry OBJECT-TYPE
+ SYNTAX VrcSupplyPtEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry in the vrcSupplyPtTable: each entry represents supply data for a
+ VRC"
+ INDEX { vrcSupplyPtIndex }
+ ::= { vrcSupplyPtTable 1 }
+
+VrcSupplyPtEntry ::= SEQUENCE {
+ vrcSupplyPtIndex Integer32,
+ vrcSupplyPtName SnmpAdminString,
+ vrcSupplyPtTemp Integer32,
+ vrcSupplyPtLowTempAlarm TruthValue,
+ vrcSupplyPtHighTempAlarm TruthValue,
+ vrcSupplyPtTempSensorFailAlarm TruthValue
+}
+
+vrcSupplyPtIndex OBJECT-TYPE
+ SYNTAX Integer32(1..100)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Unique id for each entry in the table"
+ ::= { vrcSupplyPtEntry 1 }
+
+vrcSupplyPtName OBJECT-TYPE
+ SYNTAX SnmpAdminString(SIZE (1..25))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Supply name (factory-assigned)"
+ ::= { vrcSupplyPtEntry 2 }
+
+vrcSupplyPtTemp OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "decidegrees"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Supply temperature value in tenths of a degree. Units are given by
+ temperatureUnits field in deviceInfo. The range is determined by the
+ current temperature units.
+ Celsius: -400 to 1000
+ Fahrenheit: -400 to 2120"
+ ::= { vrcSupplyPtEntry 3 }
+
+vrcSupplyPtLowTempAlarm OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Supply low temperature alarm state"
+ ::= { vrcSupplyPtEntry 4 }
+
+vrcSupplyPtHighTempAlarm OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Supply high temperature alarm state"
+ ::= { vrcSupplyPtEntry 5 }
+
+vrcSupplyPtTempSensorFailAlarm OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Supply temperature sensor failure alarm state"
+ ::= { vrcSupplyPtEntry 6 }
+
+--###########################################################################################--
+--vrcSupplyCfgTable--
+--###########################################################################################--
+
+vrcSupplyCfgTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF VrcSupplyCfgEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table used for VRC supply configuration"
+ ::= { vrc 13 }
+
+vrcSupplyCfgEntry OBJECT-TYPE
+ SYNTAX VrcSupplyCfgEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry in the vrcSupplyCfgTable: each entry contains config fields for
+ a VRC supply"
+ INDEX { vrcSupplyCfgIndex }
+ ::= { vrcSupplyCfgTable 1 }
+
+VrcSupplyCfgEntry ::= SEQUENCE {
+ vrcSupplyCfgIndex Integer32,
+ vrcSupplyCfgTempCalValue Integer32,
+ vrcSupplyCfgTempSetting Integer32,
+ vrcSupplyCfgLowTempAlarmValue Integer32,
+ vrcSupplyCfgHighTempAlarmValue Integer32,
+ vrcSupplyCfgLowTempAlmCtrl INTEGER,
+ vrcSupplyCfgHighTempAlmCtrl INTEGER,
+ vrcSupplyCfgTempSensFailAlmCtrl INTEGER
+}
+
+vrcSupplyCfgIndex OBJECT-TYPE
+ SYNTAX Integer32(1..100)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Unique id for each entry in the table"
+ ::= { vrcSupplyCfgEntry 1 }
+
+vrcSupplyCfgTempCalValue OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "decidegrees"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Supply temperature calibration value in tenths of a degree. Units are
+ given by temperatureUnits field in deviceInfo. The settable range is
+ determined by the current temperature units.
+ Celsius: -100 to 100
+ Fahrenheit: -179 to 179"
+ ::= { vrcSupplyCfgEntry 2 }
+
+vrcSupplyCfgTempSetting OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "decidegrees"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Supply temperature setting in tenths of a degree. Units are given by
+ temperatureUnits field in deviceInfo. The settable range is determined
+ by the current temperature units.
+ Celsius: 130 to 280
+ Fahrenheit: 554 to 823"
+ ::= { vrcSupplyCfgEntry 3 }
+
+vrcSupplyCfgLowTempAlarmValue OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "decidegrees"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Supply low temperature alarm value in tenths of a degree. Units are
+ given by temperatureUnits field in deviceInfo. The settable range is
+ determined by the current temperature units.
+ Celsius: 50 to 200
+ Fahrenheit: 410 to 679"
+ ::= { vrcSupplyCfgEntry 4 }
+
+vrcSupplyCfgHighTempAlarmValue OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "decidegrees"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Supply high temperature alarm value in tenths of a degree. Units are
+ given by temperatureUnits field in deviceInfo. The settable range is
+ determined by the current temperature units.
+ Celsius: 200 to 350
+ Fahrenheit: 680 to 949"
+ ::= { vrcSupplyCfgEntry 5 }
+
+vrcSupplyCfgLowTempAlmCtrl OBJECT-TYPE
+ SYNTAX INTEGER {
+ close(1),
+ suspend(2),
+ open(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Supply low temperature alarm control:
+ 1 = close
+ 2 = suspend
+ 3 = open"
+ ::= { vrcSupplyCfgEntry 6 }
+
+vrcSupplyCfgHighTempAlmCtrl OBJECT-TYPE
+ SYNTAX INTEGER {
+ close(1),
+ suspend(2),
+ open(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Supply high temperature alarm control:
+ 1 = close
+ 2 = suspend
+ 3 = open"
+ ::= { vrcSupplyCfgEntry 7 }
+
+vrcSupplyCfgTempSensFailAlmCtrl OBJECT-TYPE
+ SYNTAX INTEGER {
+ close(1),
+ suspend(2),
+ open(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Supply temperature sensor failure alarm control:
+ 1 = close
+ 2 = suspend
+ 3 = open"
+ ::= { vrcSupplyCfgEntry 8 }
+
+--###########################################################################################--
+--vrcPowerPtTable--
+--###########################################################################################--
+
+vrcPowerPtTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF VrcPowerPtEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table that contains VRC power status"
+ ::= { vrc 14 }
+
+vrcPowerPtEntry OBJECT-TYPE
+ SYNTAX VrcPowerPtEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry in the vrcPowerPtTable: each entry represents power data for a
+ VRC"
+ INDEX { vrcPowerPtIndex }
+ ::= { vrcPowerPtTable 1 }
+
+VrcPowerPtEntry ::= SEQUENCE {
+ vrcPowerPtIndex Integer32,
+ vrcPowerPtName SnmpAdminString,
+ vrcPowerPtVoltage Integer32,
+ vrcPowerPtFrequency Integer32,
+ vrcPowerPtLowVoltageAlarm TruthValue,
+ vrcPowerPtHighVoltageAlarm TruthValue,
+ vrcPowerPtLossOfPhasePowerAlarm TruthValue,
+ vrcPowerPtLossOfPowerAlarm TruthValue,
+ vrcPowerPtFrequencyErrorAlarm TruthValue
+}
+
+vrcPowerPtIndex OBJECT-TYPE
+ SYNTAX Integer32(1..100)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Unique id for each entry in the table"
+ ::= { vrcPowerPtEntry 1 }
+
+vrcPowerPtName OBJECT-TYPE
+ SYNTAX SnmpAdminString(SIZE (1..25))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Power name (factory-assigned)"
+ ::= { vrcPowerPtEntry 2 }
+
+vrcPowerPtVoltage OBJECT-TYPE
+ SYNTAX Integer32(-32768..32767)
+ UNITS "decivolts"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Power voltage measurement in tenths of a volt"
+ ::= { vrcPowerPtEntry 3 }
+
+vrcPowerPtFrequency OBJECT-TYPE
+ SYNTAX Integer32(-32768..32767)
+ UNITS "decihertz"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Power frequency measurement in tenths of hertz"
+ ::= { vrcPowerPtEntry 4 }
+
+vrcPowerPtLowVoltageAlarm OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Power low voltage alarm state"
+ ::= { vrcPowerPtEntry 5 }
+
+vrcPowerPtHighVoltageAlarm OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Power high voltage alarm state"
+ ::= { vrcPowerPtEntry 6 }
+
+vrcPowerPtLossOfPhasePowerAlarm OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Phase power loss alarm state"
+ ::= { vrcPowerPtEntry 7 }
+
+vrcPowerPtLossOfPowerAlarm OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Power loss alarm state"
+ ::= { vrcPowerPtEntry 8 }
+
+vrcPowerPtFrequencyErrorAlarm OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Power frequency error alarm state"
+ ::= { vrcPowerPtEntry 9 }
+
+--###########################################################################################--
+--vrcPowerCfgTable--
+--###########################################################################################--
+
+vrcPowerCfgTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF VrcPowerCfgEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table used for VRC power configuration"
+ ::= { vrc 15 }
+
+vrcPowerCfgEntry OBJECT-TYPE
+ SYNTAX VrcPowerCfgEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry in the vrcPowerCfgTable: each entry contains config fields for
+ VRC power"
+ INDEX { vrcPowerCfgIndex }
+ ::= { vrcPowerCfgTable 1 }
+
+VrcPowerCfgEntry ::= SEQUENCE {
+ vrcPowerCfgIndex Integer32,
+ vrcPowerCfgLowVoltageSetting Integer32,
+ vrcPowerCfgHighVoltageSetting Integer32,
+ vrcPowerCfgLowVoltageAlarmCtrl INTEGER,
+ vrcPowerCfgHighVoltageAlarmCtrl INTEGER,
+ vrcPowerCfgLossOfPowerAlarmCtrl INTEGER,
+ vrcPowerCfgFreqErrorAlarmCtrl INTEGER
+}
+
+vrcPowerCfgIndex OBJECT-TYPE
+ SYNTAX Integer32(1..100)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Unique id for each entry in the table"
+ ::= { vrcPowerCfgEntry 1 }
+
+vrcPowerCfgLowVoltageSetting OBJECT-TYPE
+ SYNTAX Integer32(100..230)
+ UNITS "volts"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Power low voltage setting in volts"
+ ::= { vrcPowerCfgEntry 2 }
+
+vrcPowerCfgHighVoltageSetting OBJECT-TYPE
+ SYNTAX Integer32(100..300)
+ UNITS "volts"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Power high voltage setting in volts"
+ ::= { vrcPowerCfgEntry 3 }
+
+vrcPowerCfgLowVoltageAlarmCtrl OBJECT-TYPE
+ SYNTAX INTEGER {
+ close(1),
+ suspend(2),
+ open(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Power low voltage alarm control:
+ 1 = close
+ 2 = suspend
+ 3 = open"
+ ::= { vrcPowerCfgEntry 4 }
+
+vrcPowerCfgHighVoltageAlarmCtrl OBJECT-TYPE
+ SYNTAX INTEGER {
+ close(1),
+ suspend(2),
+ open(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Power high voltage alarm control:
+ 1 = close
+ 2 = suspend
+ 3 = open"
+ ::= { vrcPowerCfgEntry 5 }
+
+vrcPowerCfgLossOfPowerAlarmCtrl OBJECT-TYPE
+ SYNTAX INTEGER {
+ close(1),
+ suspend(2),
+ open(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Power loss alarm control:
+ 1 = close
+ 2 = suspend
+ 3 = open"
+ ::= { vrcPowerCfgEntry 6 }
+
+vrcPowerCfgFreqErrorAlarmCtrl OBJECT-TYPE
+ SYNTAX INTEGER {
+ close(1),
+ suspend(2),
+ open(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Power frequency error alarm control:
+ 1 = close
+ 2 = suspend
+ 3 = open"
+ ::= { vrcPowerCfgEntry 7 }
+
+--###########################################################################################--
+--vrcOutdoorPtTable--
+--###########################################################################################--
+
+vrcOutdoorPtTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF VrcOutdoorPtEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table that contains VRC outdoor status"
+ ::= { vrc 16 }
+
+vrcOutdoorPtEntry OBJECT-TYPE
+ SYNTAX VrcOutdoorPtEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry in the vrcOutdoorPtTable: each entry represents data for a VRC
+ outdoor"
+ INDEX { vrcOutdoorPtIndex }
+ ::= { vrcOutdoorPtTable 1 }
+
+VrcOutdoorPtEntry ::= SEQUENCE {
+ vrcOutdoorPtIndex Integer32,
+ vrcOutdoorPtName SnmpAdminString,
+ vrcOutdoorPtTemp Integer32
+}
+
+vrcOutdoorPtIndex OBJECT-TYPE
+ SYNTAX Integer32(1..100)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Unique id for each entry in the table"
+ ::= { vrcOutdoorPtEntry 1 }
+
+vrcOutdoorPtName OBJECT-TYPE
+ SYNTAX SnmpAdminString(SIZE (1..25))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Outdoor name (factory-assigned)"
+ ::= { vrcOutdoorPtEntry 2 }
+
+vrcOutdoorPtTemp OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "decidegrees"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Outdoor temperature value in tenths of a degree. Units are given by
+ temperatureUnits field in deviceInfo. The range is determined by the
+ current temperature units.
+ Celsius: -400 to 1000
+ Fahrenheit: -400 to 2120"
+ ::= { vrcOutdoorPtEntry 3 }
+
+--###########################################################################################--
+--vrcDischPtTable--
+--###########################################################################################--
+
+vrcDischPtTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF VrcDischPtEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table that contains VRC discharge status"
+ ::= { vrc 18 }
+
+vrcDischPtEntry OBJECT-TYPE
+ SYNTAX VrcDischPtEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry in the vrcDischPtTable: each entry represents discharge data for
+ a VRC"
+ INDEX { vrcDischPtIndex }
+ ::= { vrcDischPtTable 1 }
+
+VrcDischPtEntry ::= SEQUENCE {
+ vrcDischPtIndex Integer32,
+ vrcDischPtName SnmpAdminString,
+ vrcDischPtTemp Integer32,
+ vrcDischPtPressure Integer32,
+ vrcDischPtHighTempAlarm TruthValue,
+ vrcDischPtHighTempFreqAlarm TruthValue,
+ vrcDischPtTempSensorFailAlarm TruthValue
+}
+
+vrcDischPtIndex OBJECT-TYPE
+ SYNTAX Integer32(1..100)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Unique id for each entry in the table"
+ ::= { vrcDischPtEntry 1 }
+
+vrcDischPtName OBJECT-TYPE
+ SYNTAX SnmpAdminString(SIZE (1..25))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Discharge name (factory-assigned)"
+ ::= { vrcDischPtEntry 2 }
+
+vrcDischPtTemp OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "decidegrees"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Discharge temperature value in tenths of a degree. Units are given by
+ temperatureUnits field in deviceInfo. The range is determined by the
+ current temperature units.
+ Celsius: -400 to 1560
+ Fahrenheit: -400 to 3128"
+ ::= { vrcDischPtEntry 3 }
+
+vrcDischPtPressure OBJECT-TYPE
+ SYNTAX Integer32(0..460)
+ UNITS "decibars"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Discharge air pressure value in tenths of a bar"
+ ::= { vrcDischPtEntry 4 }
+
+vrcDischPtHighTempAlarm OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Discharge high temperature alarm state"
+ ::= { vrcDischPtEntry 5 }
+
+vrcDischPtHighTempFreqAlarm OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Discharge high temperature frequently alarm state"
+ ::= { vrcDischPtEntry 6 }
+
+vrcDischPtTempSensorFailAlarm OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Discharge temperature sensor failure alarm state"
+ ::= { vrcDischPtEntry 7 }
+
+--###########################################################################################--
+--vrcDischCfgTable--
+--###########################################################################################--
+
+vrcDischCfgTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF VrcDischCfgEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table used for VRC discharge configuration"
+ ::= { vrc 19 }
+
+vrcDischCfgEntry OBJECT-TYPE
+ SYNTAX VrcDischCfgEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry in the vrcDischCfgTable: each entry contains config fields for
+ VRC discharge"
+ INDEX { vrcDischCfgIndex }
+ ::= { vrcDischCfgTable 1 }
+
+VrcDischCfgEntry ::= SEQUENCE {
+ vrcDischCfgIndex Integer32,
+ vrcDischCfgTempCalValue Integer32,
+ vrcDischCfgPressCalValue Integer32,
+ vrcDischCfgHighTempAlmCtrl INTEGER,
+ vrcDischCfgHighTempFreqAlmCtrl INTEGER,
+ vrcDischCfgTempSensFailAlmCtrl INTEGER
+}
+
+vrcDischCfgIndex OBJECT-TYPE
+ SYNTAX Integer32(1..100)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Unique id for each entry in the table"
+ ::= { vrcDischCfgEntry 1 }
+
+vrcDischCfgTempCalValue OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "decidegrees"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Discharge temperature calibration value in tenths of a degree. Units
+ are given by temperatureUnits field in deviceInfo. The settable range
+ is determined by the current temperature units.
+ Celsius: -100 to 100
+ Fahrenheit: -179 to 179"
+ ::= { vrcDischCfgEntry 2 }
+
+vrcDischCfgPressCalValue OBJECT-TYPE
+ SYNTAX Integer32(-100..100)
+ UNITS "decibars"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Discharge pressure calibration value in tenths of a bar"
+ ::= { vrcDischCfgEntry 3 }
+
+vrcDischCfgHighTempAlmCtrl OBJECT-TYPE
+ SYNTAX INTEGER {
+ suspend(2),
+ open(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Discharge high temperature alarm control:
+ 2 = suspend
+ 3 = open"
+ ::= { vrcDischCfgEntry 4 }
+
+vrcDischCfgHighTempFreqAlmCtrl OBJECT-TYPE
+ SYNTAX INTEGER {
+ suspend(2),
+ open(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Discharge high temperature frequenctly alarm control:
+ 2 = suspend
+ 3 = open"
+ ::= { vrcDischCfgEntry 5 }
+
+vrcDischCfgTempSensFailAlmCtrl OBJECT-TYPE
+ SYNTAX INTEGER {
+ suspend(2),
+ open(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Discharge temperature sensor failure alarm control:
+ 2 = suspend
+ 3 = open"
+ ::= { vrcDischCfgEntry 6 }
+
+--###########################################################################################--
+--vrcSuctPtTable--
+--###########################################################################################--
+
+vrcSuctPtTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF VrcSuctPtEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table that contains VRC suction status"
+ ::= { vrc 20 }
+
+vrcSuctPtEntry OBJECT-TYPE
+ SYNTAX VrcSuctPtEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry in the vrcSuctPtTable: each entry represents suction data for a
+ VRC"
+ INDEX { vrcSuctPtIndex }
+ ::= { vrcSuctPtTable 1 }
+
+VrcSuctPtEntry ::= SEQUENCE {
+ vrcSuctPtIndex Integer32,
+ vrcSuctPtName SnmpAdminString,
+ vrcSuctPtTemp Integer32,
+ vrcSuctPtPressure Integer32,
+ vrcSuctPtSuperHeatTemp Integer32,
+ vrcSuctPtTempSensorFailAlarm TruthValue
+}
+
+vrcSuctPtIndex OBJECT-TYPE
+ SYNTAX Integer32(1..100)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Unique id for each entry in the table"
+ ::= { vrcSuctPtEntry 1 }
+
+vrcSuctPtName OBJECT-TYPE
+ SYNTAX SnmpAdminString(SIZE (1..25))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Suction name (factory-assigned)"
+ ::= { vrcSuctPtEntry 2 }
+
+vrcSuctPtTemp OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "decidegrees"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Suction temperature in tenths of a degree. Units are given by
+ temperatureUnits field in deviceInfo. The range is determined by the
+ current temperature units.
+ Celsius: -400 to 1000
+ Fahrenheit: -400 to 2120"
+ ::= { vrcSuctPtEntry 3 }
+
+vrcSuctPtPressure OBJECT-TYPE
+ SYNTAX Integer32(0..173)
+ UNITS "decibars"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Suction air pressure in tenths of a bar"
+ ::= { vrcSuctPtEntry 4 }
+
+vrcSuctPtSuperHeatTemp OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "decidegrees"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Suction super heat temperature in tenths of a degree. Units are given
+ by temperatureUnits field in deviceInfo. The range is determined by
+ the current temperature units.
+ Celsius: -400 to 1000
+ Fahrenheit: -400 to 2120"
+ ::= { vrcSuctPtEntry 5 }
+
+vrcSuctPtTempSensorFailAlarm OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Suction temperature sensor failure alarm state"
+ ::= { vrcSuctPtEntry 6 }
+
+--###########################################################################################--
+--vrcSuctCfgTable--
+--###########################################################################################--
+
+vrcSuctCfgTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF VrcSuctCfgEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table used for VRC suction configuration"
+ ::= { vrc 21 }
+
+vrcSuctCfgEntry OBJECT-TYPE
+ SYNTAX VrcSuctCfgEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry in the vrcSuctCfgTable: each entry contains config fields for
+ VRC suction"
+ INDEX { vrcSuctCfgIndex }
+ ::= { vrcSuctCfgTable 1 }
+
+VrcSuctCfgEntry ::= SEQUENCE {
+ vrcSuctCfgIndex Integer32,
+ vrcSuctCfgPressCalValue Integer32,
+ vrcSuctCfgTempSensFailAlmCtrl INTEGER
+}
+
+vrcSuctCfgIndex OBJECT-TYPE
+ SYNTAX Integer32(1..100)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Unique id for each entry in the table"
+ ::= { vrcSuctCfgEntry 1 }
+
+vrcSuctCfgPressCalValue OBJECT-TYPE
+ SYNTAX Integer32(-100..100)
+ UNITS "decibars"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Suction pressure calibration value in tenths of a bar"
+ ::= { vrcSuctCfgEntry 2 }
+
+vrcSuctCfgTempSensFailAlmCtrl OBJECT-TYPE
+ SYNTAX INTEGER {
+ suspend(2),
+ open(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Suction temperature sensor failure alarm control:
+ 2 = suspend
+ 3 = open"
+ ::= { vrcSuctCfgEntry 3 }
+
+--###########################################################################################--
+--Notifications--
+--###########################################################################################--
+
+trap OBJECT IDENTIFIER ::= { imd 32767 }
+
+trapPrefix OBJECT IDENTIFIER ::= { trap 0 }
+
+trapObj OBJECT IDENTIFIER ::= { trap 1 }
+
+
+trapSeverity OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(0),
+ warning(1),
+ alarm(2)
+ }
+ MAX-ACCESS accessible-for-notify
+ STATUS current
+ DESCRIPTION
+ "Indicates the severity of the trap:
+ 0 = None
+ 1 = Warning
+ 2 = Alarm"
+ ::= { trapObj 1 }
+
+trapThreshType OBJECT-TYPE
+ SYNTAX INTEGER {
+ low(1),
+ high(2)
+ }
+ MAX-ACCESS accessible-for-notify
+ STATUS current
+ DESCRIPTION
+ "Only sent for threshold alarms. Identifies the threshold type:
+ 1 = Low
+ 2 = High"
+ ::= { trapObj 2 }
+
+internalTestNOTIFY NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION "Test SNMP Trap"
+ ::= { trapPrefix 10101 }
+
+--#####deviceInfo#####--
+
+--#####pdu#####--
+
+--#####pduMainTable#####--
+
+pduMainAvailNOTIFY NOTIFICATION-TYPE
+ OBJECTS {
+ pduMainAvail,
+ trapSeverity,
+ sysName,
+ pduMainLabel
+ }
+ STATUS current
+ DESCRIPTION "PDU availability trap"
+ ::= { trapPrefix 10305 }
+
+pduMainAvailCLEAR NOTIFICATION-TYPE
+ OBJECTS {
+ pduMainAvail,
+ trapSeverity,
+ sysName,
+ pduMainLabel
+ }
+ STATUS current
+ DESCRIPTION "PDU availability clear trap"
+ ::= { trapPrefix 20305 }
+
+pduTotalRealPowerNOTIFY NOTIFICATION-TYPE
+ OBJECTS {
+ pduTotalRealPower,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ pduMainLabel,
+ pduTotalLabel
+ }
+ STATUS current
+ DESCRIPTION "PDU total real power trap"
+ ::= { trapPrefix 10309 }
+
+pduTotalRealPowerCLEAR NOTIFICATION-TYPE
+ OBJECTS {
+ pduTotalRealPower,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ pduMainLabel,
+ pduTotalLabel
+ }
+ STATUS current
+ DESCRIPTION "PDU total real power clear trap"
+ ::= { trapPrefix 20309 }
+
+pduTotalApparentPowerNOTIFY NOTIFICATION-TYPE
+ OBJECTS {
+ pduTotalApparentPower,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ pduMainLabel,
+ pduTotalLabel
+ }
+ STATUS current
+ DESCRIPTION "PDU total apparent power trap"
+ ::= { trapPrefix 10310 }
+
+pduTotalApparentPowerCLEAR NOTIFICATION-TYPE
+ OBJECTS {
+ pduTotalApparentPower,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ pduMainLabel,
+ pduTotalLabel
+ }
+ STATUS current
+ DESCRIPTION "PDU total apparent power clear trap"
+ ::= { trapPrefix 20310 }
+
+pduTotalPowerFactorNOTIFY NOTIFICATION-TYPE
+ OBJECTS {
+ pduTotalPowerFactor,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ pduMainLabel,
+ pduTotalLabel
+ }
+ STATUS current
+ DESCRIPTION "PDU total power factor trap"
+ ::= { trapPrefix 10311 }
+
+pduTotalPowerFactorCLEAR NOTIFICATION-TYPE
+ OBJECTS {
+ pduTotalPowerFactor,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ pduMainLabel,
+ pduTotalLabel
+ }
+ STATUS current
+ DESCRIPTION "PDU total power factor clear trap"
+ ::= { trapPrefix 20311 }
+
+pduTotalEnergyNOTIFY NOTIFICATION-TYPE
+ OBJECTS {
+ pduTotalEnergy,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ pduMainLabel,
+ pduTotalLabel
+ }
+ STATUS current
+ DESCRIPTION "PDU total energy trap"
+ ::= { trapPrefix 10312 }
+
+pduTotalEnergyCLEAR NOTIFICATION-TYPE
+ OBJECTS {
+ pduTotalEnergy,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ pduMainLabel,
+ pduTotalLabel
+ }
+ STATUS current
+ DESCRIPTION "PDU total energy clear trap"
+ ::= { trapPrefix 20312 }
+
+--#####pduPhaseTable#####--
+
+pduPhaseVoltageNOTIFY NOTIFICATION-TYPE
+ OBJECTS {
+ pduPhaseVoltage,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ pduMainLabel,
+ pduPhaseLabel
+ }
+ STATUS current
+ DESCRIPTION "PDU phase voltage trap"
+ ::= { trapPrefix 10324 }
+
+pduPhaseVoltageCLEAR NOTIFICATION-TYPE
+ OBJECTS {
+ pduPhaseVoltage,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ pduMainLabel,
+ pduPhaseLabel
+ }
+ STATUS current
+ DESCRIPTION "PDU phase voltage clear trap"
+ ::= { trapPrefix 20324 }
+
+pduPhaseCurrentNOTIFY NOTIFICATION-TYPE
+ OBJECTS {
+ pduPhaseCurrent,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ pduMainLabel,
+ pduPhaseLabel
+ }
+ STATUS current
+ DESCRIPTION "PDU phase current trap"
+ ::= { trapPrefix 10328 }
+
+pduPhaseCurrentCLEAR NOTIFICATION-TYPE
+ OBJECTS {
+ pduPhaseCurrent,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ pduMainLabel,
+ pduPhaseLabel
+ }
+ STATUS current
+ DESCRIPTION "PDU phase current clear trap"
+ ::= { trapPrefix 20328 }
+
+pduPhaseRealPowerNOTIFY NOTIFICATION-TYPE
+ OBJECTS {
+ pduPhaseRealPower,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ pduMainLabel,
+ pduPhaseLabel
+ }
+ STATUS current
+ DESCRIPTION "PDU phase real power trap"
+ ::= { trapPrefix 10332 }
+
+pduPhaseRealPowerCLEAR NOTIFICATION-TYPE
+ OBJECTS {
+ pduPhaseRealPower,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ pduMainLabel,
+ pduPhaseLabel
+ }
+ STATUS current
+ DESCRIPTION "PDU phase real power clear trap"
+ ::= { trapPrefix 20332 }
+
+pduPhaseApparentPowerNOTIFY NOTIFICATION-TYPE
+ OBJECTS {
+ pduPhaseApparentPower,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ pduMainLabel,
+ pduPhaseLabel
+ }
+ STATUS current
+ DESCRIPTION "PDU phase apparent power trap"
+ ::= { trapPrefix 10333 }
+
+pduPhaseApparentPowerCLEAR NOTIFICATION-TYPE
+ OBJECTS {
+ pduPhaseApparentPower,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ pduMainLabel,
+ pduPhaseLabel
+ }
+ STATUS current
+ DESCRIPTION "PDU phase apparent power clear trap"
+ ::= { trapPrefix 20333 }
+
+pduPhasePowerFactorNOTIFY NOTIFICATION-TYPE
+ OBJECTS {
+ pduPhasePowerFactor,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ pduMainLabel,
+ pduPhaseLabel
+ }
+ STATUS current
+ DESCRIPTION "PDU phase power factor trap"
+ ::= { trapPrefix 10334 }
+
+pduPhasePowerFactorCLEAR NOTIFICATION-TYPE
+ OBJECTS {
+ pduPhasePowerFactor,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ pduMainLabel,
+ pduPhaseLabel
+ }
+ STATUS current
+ DESCRIPTION "PDU phase power factor clear trap"
+ ::= { trapPrefix 20334 }
+
+pduPhaseEnergyNOTIFY NOTIFICATION-TYPE
+ OBJECTS {
+ pduPhaseEnergy,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ pduMainLabel,
+ pduPhaseLabel
+ }
+ STATUS current
+ DESCRIPTION "PDU phase energy trap"
+ ::= { trapPrefix 10335 }
+
+pduPhaseEnergyCLEAR NOTIFICATION-TYPE
+ OBJECTS {
+ pduPhaseEnergy,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ pduMainLabel,
+ pduPhaseLabel
+ }
+ STATUS current
+ DESCRIPTION "PDU phase energy clear trap"
+ ::= { trapPrefix 20335 }
+
+pduPhaseBalanceNOTIFY NOTIFICATION-TYPE
+ OBJECTS {
+ pduPhaseBalance,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ pduMainLabel,
+ pduPhaseLabel
+ }
+ STATUS current
+ DESCRIPTION "PDU phase balance trap"
+ ::= { trapPrefix 10337 }
+
+pduPhaseBalanceCLEAR NOTIFICATION-TYPE
+ OBJECTS {
+ pduPhaseBalance,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ pduMainLabel,
+ pduPhaseLabel
+ }
+ STATUS current
+ DESCRIPTION "PDU phase balance clear trap"
+ ::= { trapPrefix 20337 }
+
+pduPhaseCurrentCrestFactorNOTIFY NOTIFICATION-TYPE
+ OBJECTS {
+ pduPhaseCurrentCrestFactor,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ pduMainLabel,
+ pduPhaseLabel
+ }
+ STATUS current
+ DESCRIPTION "PDU phase current crest factor trap"
+ ::= { trapPrefix 10339 }
+
+pduPhaseCurrentCrestFactorCLEAR NOTIFICATION-TYPE
+ OBJECTS {
+ pduPhaseCurrentCrestFactor,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ pduMainLabel,
+ pduPhaseLabel
+ }
+ STATUS current
+ DESCRIPTION "PDU phase current crest factor clear trap"
+ ::= { trapPrefix 20339 }
+
+--#####pduBreakerTable#####--
+
+pduBreakerCurrentNOTIFY NOTIFICATION-TYPE
+ OBJECTS {
+ pduBreakerCurrent,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ pduMainLabel,
+ pduBreakerLabel
+ }
+ STATUS current
+ DESCRIPTION "PDU breaker current trap"
+ ::= { trapPrefix 10354 }
+
+pduBreakerCurrentCLEAR NOTIFICATION-TYPE
+ OBJECTS {
+ pduBreakerCurrent,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ pduMainLabel,
+ pduBreakerLabel
+ }
+ STATUS current
+ DESCRIPTION "PDU breaker current clear trap"
+ ::= { trapPrefix 20354 }
+
+pduBreakerVoltageNOTIFY NOTIFICATION-TYPE
+ OBJECTS {
+ pduBreakerVoltage,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ pduMainLabel,
+ pduBreakerLabel
+ }
+ STATUS current
+ DESCRIPTION "PDU breaker voltage trap"
+ ::= { trapPrefix 10358 }
+
+pduBreakerVoltageCLEAR NOTIFICATION-TYPE
+ OBJECTS {
+ pduBreakerVoltage,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ pduMainLabel,
+ pduBreakerLabel
+ }
+ STATUS current
+ DESCRIPTION "PDU breaker voltage clear trap"
+ ::= { trapPrefix 20358 }
+
+pduBreakerRealPowerNOTIFY NOTIFICATION-TYPE
+ OBJECTS {
+ pduBreakerRealPower,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ pduMainLabel,
+ pduBreakerLabel
+ }
+ STATUS current
+ DESCRIPTION "PDU breaker real power trap"
+ ::= { trapPrefix 10362 }
+
+pduBreakerRealPowerCLEAR NOTIFICATION-TYPE
+ OBJECTS {
+ pduBreakerRealPower,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ pduMainLabel,
+ pduBreakerLabel
+ }
+ STATUS current
+ DESCRIPTION "PDU breaker real power clear trap"
+ ::= { trapPrefix 20362 }
+
+pduBreakerApparentPowerNOTIFY NOTIFICATION-TYPE
+ OBJECTS {
+ pduBreakerApparentPower,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ pduMainLabel,
+ pduBreakerLabel
+ }
+ STATUS current
+ DESCRIPTION "PDU breaker apparent power trap"
+ ::= { trapPrefix 10363 }
+
+pduBreakerApparentPowerCLEAR NOTIFICATION-TYPE
+ OBJECTS {
+ pduBreakerApparentPower,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ pduMainLabel,
+ pduBreakerLabel
+ }
+ STATUS current
+ DESCRIPTION "PDU breaker apparent power clear trap"
+ ::= { trapPrefix 20363 }
+
+pduBreakerPowerFactorNOTIFY NOTIFICATION-TYPE
+ OBJECTS {
+ pduBreakerPowerFactor,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ pduMainLabel,
+ pduBreakerLabel
+ }
+ STATUS current
+ DESCRIPTION "PDU breaker power factor trap"
+ ::= { trapPrefix 10364 }
+
+pduBreakerPowerFactorCLEAR NOTIFICATION-TYPE
+ OBJECTS {
+ pduBreakerPowerFactor,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ pduMainLabel,
+ pduBreakerLabel
+ }
+ STATUS current
+ DESCRIPTION "PDU breaker power factor clear trap"
+ ::= { trapPrefix 20364 }
+
+pduBreakerEnergyNOTIFY NOTIFICATION-TYPE
+ OBJECTS {
+ pduBreakerEnergy,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ pduMainLabel,
+ pduBreakerLabel
+ }
+ STATUS current
+ DESCRIPTION "PDU breaker energy trap"
+ ::= { trapPrefix 10365 }
+
+pduBreakerEnergyCLEAR NOTIFICATION-TYPE
+ OBJECTS {
+ pduBreakerEnergy,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ pduMainLabel,
+ pduBreakerLabel
+ }
+ STATUS current
+ DESCRIPTION "PDU breaker energy clear trap"
+ ::= { trapPrefix 20365 }
+
+--#####pduLineTable#####--
+
+pduLineCurrentNOTIFY NOTIFICATION-TYPE
+ OBJECTS {
+ pduLineCurrent,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ pduMainLabel,
+ pduLineLabel
+ }
+ STATUS current
+ DESCRIPTION "PDU line current trap"
+ ::= { trapPrefix 10374 }
+
+pduLineCurrentCLEAR NOTIFICATION-TYPE
+ OBJECTS {
+ pduLineCurrent,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ pduMainLabel,
+ pduLineLabel
+ }
+ STATUS current
+ DESCRIPTION "PDU line current clear trap"
+ ::= { trapPrefix 20374 }
+
+--#####pduOutletSwitchTable#####--
+
+--#####pduOutletMeterTable#####--
+
+pduOutletMeterVoltageNOTIFY NOTIFICATION-TYPE
+ OBJECTS {
+ pduOutletMeterVoltage,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ pduMainLabel,
+ pduOutletMeterLabel
+ }
+ STATUS current
+ DESCRIPTION "PDU outlet voltage trap"
+ ::= { trapPrefix 10385 }
+
+pduOutletMeterVoltageCLEAR NOTIFICATION-TYPE
+ OBJECTS {
+ pduOutletMeterVoltage,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ pduMainLabel,
+ pduOutletMeterLabel
+ }
+ STATUS current
+ DESCRIPTION "PDU outlet voltage clear trap"
+ ::= { trapPrefix 20385 }
+
+pduOutletMeterCurrentNOTIFY NOTIFICATION-TYPE
+ OBJECTS {
+ pduOutletMeterCurrent,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ pduMainLabel,
+ pduOutletMeterLabel
+ }
+ STATUS current
+ DESCRIPTION "PDU outlet current trap"
+ ::= { trapPrefix 10389 }
+
+pduOutletMeterCurrentCLEAR NOTIFICATION-TYPE
+ OBJECTS {
+ pduOutletMeterCurrent,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ pduMainLabel,
+ pduOutletMeterLabel
+ }
+ STATUS current
+ DESCRIPTION "PDU outlet current clear trap"
+ ::= { trapPrefix 20389 }
+
+pduOutletMeterRealPowerNOTIFY NOTIFICATION-TYPE
+ OBJECTS {
+ pduOutletMeterRealPower,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ pduMainLabel,
+ pduOutletMeterLabel
+ }
+ STATUS current
+ DESCRIPTION "PDU outlet real power trap"
+ ::= { trapPrefix 10393 }
+
+pduOutletMeterRealPowerCLEAR NOTIFICATION-TYPE
+ OBJECTS {
+ pduOutletMeterRealPower,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ pduMainLabel,
+ pduOutletMeterLabel
+ }
+ STATUS current
+ DESCRIPTION "PDU outlet real power clear trap"
+ ::= { trapPrefix 20393 }
+
+pduOutletMeterApparentPowerNOTIFY NOTIFICATION-TYPE
+ OBJECTS {
+ pduOutletMeterApparentPower,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ pduMainLabel,
+ pduOutletMeterLabel
+ }
+ STATUS current
+ DESCRIPTION "PDU outlet apparent power trap"
+ ::= { trapPrefix 10394 }
+
+pduOutletMeterApparentPowerCLEAR NOTIFICATION-TYPE
+ OBJECTS {
+ pduOutletMeterApparentPower,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ pduMainLabel,
+ pduOutletMeterLabel
+ }
+ STATUS current
+ DESCRIPTION "PDU outlet apparent power clear trap"
+ ::= { trapPrefix 20394 }
+
+pduOutletMeterPowerFactorNOTIFY NOTIFICATION-TYPE
+ OBJECTS {
+ pduOutletMeterPowerFactor,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ pduMainLabel,
+ pduOutletMeterLabel
+ }
+ STATUS current
+ DESCRIPTION "PDU outlet power factor trap"
+ ::= { trapPrefix 10395 }
+
+pduOutletMeterPowerFactorCLEAR NOTIFICATION-TYPE
+ OBJECTS {
+ pduOutletMeterPowerFactor,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ pduMainLabel,
+ pduOutletMeterLabel
+ }
+ STATUS current
+ DESCRIPTION "PDU outlet power factor clear trap"
+ ::= { trapPrefix 20395 }
+
+pduOutletMeterEnergyNOTIFY NOTIFICATION-TYPE
+ OBJECTS {
+ pduOutletMeterEnergy,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ pduMainLabel,
+ pduOutletMeterLabel
+ }
+ STATUS current
+ DESCRIPTION "PDU outlet energy trap"
+ ::= { trapPrefix 10396 }
+
+pduOutletMeterEnergyCLEAR NOTIFICATION-TYPE
+ OBJECTS {
+ pduOutletMeterEnergy,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ pduMainLabel,
+ pduOutletMeterLabel
+ }
+ STATUS current
+ DESCRIPTION "PDU outlet energy clear trap"
+ ::= { trapPrefix 20396 }
+
+pduOutletCurrentCrestFactorNOTIFY NOTIFICATION-TYPE
+ OBJECTS {
+ pduOutletCurrentCrestFactor,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ pduMainLabel,
+ pduOutletMeterLabel
+ }
+ STATUS current
+ DESCRIPTION "PDU outlet current crest factor trap"
+ ::= { trapPrefix 10400 }
+
+pduOutletCurrentCrestFactorCLEAR NOTIFICATION-TYPE
+ OBJECTS {
+ pduOutletCurrentCrestFactor,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ pduMainLabel,
+ pduOutletMeterLabel
+ }
+ STATUS current
+ DESCRIPTION "PDU outlet current crest factor clear trap"
+ ::= { trapPrefix 20400 }
+
+--#####tempSensorTable#####--
+
+tempSensorAvailNOTIFY NOTIFICATION-TYPE
+ OBJECTS {
+ tempSensorAvail,
+ trapSeverity,
+ sysName,
+ tempSensorLabel
+ }
+ STATUS current
+ DESCRIPTION "RT availability trap"
+ ::= { trapPrefix 10404 }
+
+tempSensorAvailCLEAR NOTIFICATION-TYPE
+ OBJECTS {
+ tempSensorAvail,
+ trapSeverity,
+ sysName,
+ tempSensorLabel
+ }
+ STATUS current
+ DESCRIPTION "RT availability clear trap"
+ ::= { trapPrefix 20404 }
+
+tempSensorTempNOTIFY NOTIFICATION-TYPE
+ OBJECTS {
+ tempSensorTemp,
+ temperatureUnits,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ tempSensorLabel
+ }
+ STATUS current
+ DESCRIPTION "RT temperature trap"
+ ::= { trapPrefix 10405 }
+
+tempSensorTempCLEAR NOTIFICATION-TYPE
+ OBJECTS {
+ tempSensorTemp,
+ temperatureUnits,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ tempSensorLabel
+ }
+ STATUS current
+ DESCRIPTION "RT temperature clear trap"
+ ::= { trapPrefix 20405 }
+
+--#####airFlowSensorTable#####--
+
+airFlowSensorAvailNOTIFY NOTIFICATION-TYPE
+ OBJECTS {
+ airFlowSensorAvail,
+ trapSeverity,
+ sysName,
+ airFlowSensorLabel
+ }
+ STATUS current
+ DESCRIPTION "AFHT3 availability trap"
+ ::= { trapPrefix 10504 }
+
+airFlowSensorAvailCLEAR NOTIFICATION-TYPE
+ OBJECTS {
+ airFlowSensorAvail,
+ trapSeverity,
+ sysName,
+ airFlowSensorLabel
+ }
+ STATUS current
+ DESCRIPTION "AFHT3 availability clear trap"
+ ::= { trapPrefix 20504 }
+
+airFlowSensorTempNOTIFY NOTIFICATION-TYPE
+ OBJECTS {
+ airFlowSensorTemp,
+ temperatureUnits,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ airFlowSensorLabel
+ }
+ STATUS current
+ DESCRIPTION "AFHT3 temperature trap"
+ ::= { trapPrefix 10505 }
+
+airFlowSensorTempCLEAR NOTIFICATION-TYPE
+ OBJECTS {
+ airFlowSensorTemp,
+ temperatureUnits,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ airFlowSensorLabel
+ }
+ STATUS current
+ DESCRIPTION "AFHT3 temperature clear trap"
+ ::= { trapPrefix 20505 }
+
+airFlowSensorFlowNOTIFY NOTIFICATION-TYPE
+ OBJECTS {
+ airFlowSensorFlow,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ airFlowSensorLabel
+ }
+ STATUS current
+ DESCRIPTION "AFHT3 airflow trap"
+ ::= { trapPrefix 10506 }
+
+airFlowSensorFlowCLEAR NOTIFICATION-TYPE
+ OBJECTS {
+ airFlowSensorFlow,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ airFlowSensorLabel
+ }
+ STATUS current
+ DESCRIPTION "AFHT3 airflow clear trap"
+ ::= { trapPrefix 20506 }
+
+airFlowSensorHumidityNOTIFY NOTIFICATION-TYPE
+ OBJECTS {
+ airFlowSensorHumidity,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ airFlowSensorLabel
+ }
+ STATUS current
+ DESCRIPTION "AFHT3 humidity trap"
+ ::= { trapPrefix 10507 }
+
+airFlowSensorHumidityCLEAR NOTIFICATION-TYPE
+ OBJECTS {
+ airFlowSensorHumidity,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ airFlowSensorLabel
+ }
+ STATUS current
+ DESCRIPTION "AFHT3 humidity clear trap"
+ ::= { trapPrefix 20507 }
+
+airFlowSensorDewPointNOTIFY NOTIFICATION-TYPE
+ OBJECTS {
+ airFlowSensorDewPoint,
+ temperatureUnits,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ airFlowSensorLabel
+ }
+ STATUS current
+ DESCRIPTION "AFHT3 dewpoint trap"
+ ::= { trapPrefix 10508 }
+
+airFlowSensorDewPointCLEAR NOTIFICATION-TYPE
+ OBJECTS {
+ airFlowSensorDewPoint,
+ temperatureUnits,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ airFlowSensorLabel
+ }
+ STATUS current
+ DESCRIPTION "AFHT3 dewpoint clear trap"
+ ::= { trapPrefix 20508 }
+
+--#####t3hdSensorTable#####--
+
+t3hdSensorAvailNOTIFY NOTIFICATION-TYPE
+ OBJECTS {
+ t3hdSensorAvail,
+ trapSeverity,
+ sysName,
+ t3hdSensorLabel
+ }
+ STATUS current
+ DESCRIPTION "T3HD availability trap"
+ ::= { trapPrefix 10804 }
+
+t3hdSensorAvailCLEAR NOTIFICATION-TYPE
+ OBJECTS {
+ t3hdSensorAvail,
+ trapSeverity,
+ sysName,
+ t3hdSensorLabel
+ }
+ STATUS current
+ DESCRIPTION "T3HD availability clear trap"
+ ::= { trapPrefix 20804 }
+
+t3hdSensorIntTempNOTIFY NOTIFICATION-TYPE
+ OBJECTS {
+ t3hdSensorIntTemp,
+ temperatureUnits,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ t3hdSensorLabel,
+ t3hdSensorIntLabel
+ }
+ STATUS current
+ DESCRIPTION "T3HD Internal temperature trap"
+ ::= { trapPrefix 10806 }
+
+t3hdSensorIntTempCLEAR NOTIFICATION-TYPE
+ OBJECTS {
+ t3hdSensorIntTemp,
+ temperatureUnits,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ t3hdSensorLabel,
+ t3hdSensorIntLabel
+ }
+ STATUS current
+ DESCRIPTION "T3HD Internal temperature clear trap"
+ ::= { trapPrefix 20806 }
+
+t3hdSensorIntHumidityNOTIFY NOTIFICATION-TYPE
+ OBJECTS {
+ t3hdSensorIntHumidity,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ t3hdSensorLabel,
+ t3hdSensorIntLabel
+ }
+ STATUS current
+ DESCRIPTION "T3HD Internal humidity trap"
+ ::= { trapPrefix 10807 }
+
+t3hdSensorIntHumidityCLEAR NOTIFICATION-TYPE
+ OBJECTS {
+ t3hdSensorIntHumidity,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ t3hdSensorLabel,
+ t3hdSensorIntLabel
+ }
+ STATUS current
+ DESCRIPTION "T3HD Internal humidity clear trap"
+ ::= { trapPrefix 20807 }
+
+t3hdSensorIntDewPointNOTIFY NOTIFICATION-TYPE
+ OBJECTS {
+ t3hdSensorIntDewPoint,
+ temperatureUnits,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ t3hdSensorLabel,
+ t3hdSensorIntLabel
+ }
+ STATUS current
+ DESCRIPTION "T3HD Internal dewpoint trap"
+ ::= { trapPrefix 10808 }
+
+t3hdSensorIntDewPointCLEAR NOTIFICATION-TYPE
+ OBJECTS {
+ t3hdSensorIntDewPoint,
+ temperatureUnits,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ t3hdSensorLabel,
+ t3hdSensorIntLabel
+ }
+ STATUS current
+ DESCRIPTION "T3HD Internal dewpoint clear trap"
+ ::= { trapPrefix 20808 }
+
+t3hdSensorExtATempNOTIFY NOTIFICATION-TYPE
+ OBJECTS {
+ t3hdSensorExtATemp,
+ temperatureUnits,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ t3hdSensorLabel,
+ t3hdSensorExtALabel
+ }
+ STATUS current
+ DESCRIPTION "T3HD External A temperature trap"
+ ::= { trapPrefix 10811 }
+
+t3hdSensorExtATempCLEAR NOTIFICATION-TYPE
+ OBJECTS {
+ t3hdSensorExtATemp,
+ temperatureUnits,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ t3hdSensorLabel,
+ t3hdSensorExtALabel
+ }
+ STATUS current
+ DESCRIPTION "T3HD External A temperature clear trap"
+ ::= { trapPrefix 20811 }
+
+t3hdSensorExtBTempNOTIFY NOTIFICATION-TYPE
+ OBJECTS {
+ t3hdSensorExtBTemp,
+ temperatureUnits,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ t3hdSensorLabel,
+ t3hdSensorExtBLabel
+ }
+ STATUS current
+ DESCRIPTION "T3HD External B temperature trap"
+ ::= { trapPrefix 10814 }
+
+t3hdSensorExtBTempCLEAR NOTIFICATION-TYPE
+ OBJECTS {
+ t3hdSensorExtBTemp,
+ temperatureUnits,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ t3hdSensorLabel,
+ t3hdSensorExtBLabel
+ }
+ STATUS current
+ DESCRIPTION "T3HD External B temperature clear trap"
+ ::= { trapPrefix 20814 }
+
+--#####thdSensorTable#####--
+
+thdSensorAvailNOTIFY NOTIFICATION-TYPE
+ OBJECTS {
+ thdSensorAvail,
+ trapSeverity,
+ sysName,
+ thdSensorLabel
+ }
+ STATUS current
+ DESCRIPTION "THD availability trap"
+ ::= { trapPrefix 10904 }
+
+thdSensorAvailCLEAR NOTIFICATION-TYPE
+ OBJECTS {
+ thdSensorAvail,
+ trapSeverity,
+ sysName,
+ thdSensorLabel
+ }
+ STATUS current
+ DESCRIPTION "THD availability clear trap"
+ ::= { trapPrefix 20904 }
+
+thdSensorTempNOTIFY NOTIFICATION-TYPE
+ OBJECTS {
+ thdSensorTemp,
+ temperatureUnits,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ thdSensorLabel
+ }
+ STATUS current
+ DESCRIPTION "THD temperature trap"
+ ::= { trapPrefix 10905 }
+
+thdSensorTempCLEAR NOTIFICATION-TYPE
+ OBJECTS {
+ thdSensorTemp,
+ temperatureUnits,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ thdSensorLabel
+ }
+ STATUS current
+ DESCRIPTION "THD temperature clear trap"
+ ::= { trapPrefix 20905 }
+
+thdSensorHumidityNOTIFY NOTIFICATION-TYPE
+ OBJECTS {
+ thdSensorHumidity,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ thdSensorLabel
+ }
+ STATUS current
+ DESCRIPTION "THD humidity trap"
+ ::= { trapPrefix 10906 }
+
+thdSensorHumidityCLEAR NOTIFICATION-TYPE
+ OBJECTS {
+ thdSensorHumidity,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ thdSensorLabel
+ }
+ STATUS current
+ DESCRIPTION "THD humidity clear trap"
+ ::= { trapPrefix 20906 }
+
+thdSensorDewPointNOTIFY NOTIFICATION-TYPE
+ OBJECTS {
+ thdSensorDewPoint,
+ temperatureUnits,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ thdSensorLabel
+ }
+ STATUS current
+ DESCRIPTION "THD dewpoint trap"
+ ::= { trapPrefix 10907 }
+
+thdSensorDewPointCLEAR NOTIFICATION-TYPE
+ OBJECTS {
+ thdSensorDewPoint,
+ temperatureUnits,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ thdSensorLabel
+ }
+ STATUS current
+ DESCRIPTION "THD dewpoint clear trap"
+ ::= { trapPrefix 20907 }
+
+--#####a2dSensorTable#####--
+
+a2dSensorAvailNOTIFY NOTIFICATION-TYPE
+ OBJECTS {
+ a2dSensorAvail,
+ trapSeverity,
+ sysName,
+ a2dSensorLabel
+ }
+ STATUS current
+ DESCRIPTION "A2D availability trap"
+ ::= { trapPrefix 11104 }
+
+a2dSensorAvailCLEAR NOTIFICATION-TYPE
+ OBJECTS {
+ a2dSensorAvail,
+ trapSeverity,
+ sysName,
+ a2dSensorLabel
+ }
+ STATUS current
+ DESCRIPTION "A2D availability clear trap"
+ ::= { trapPrefix 21104 }
+
+a2dSensorValueNOTIFY NOTIFICATION-TYPE
+ OBJECTS {
+ a2dSensorValue,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ a2dSensorLabel,
+ a2dSensorAnalogLabel,
+ a2dSensorDisplayValue
+ }
+ STATUS current
+ DESCRIPTION "A2D measurement trap"
+ ::= { trapPrefix 11105 }
+
+a2dSensorValueCLEAR NOTIFICATION-TYPE
+ OBJECTS {
+ a2dSensorValue,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ a2dSensorLabel,
+ a2dSensorAnalogLabel,
+ a2dSensorDisplayValue
+ }
+ STATUS current
+ DESCRIPTION "A2D measurement clear trap"
+ ::= { trapPrefix 21105 }
+
+--#####humiditySensorTable#####--
+
+humiditySensorAvailNOTIFY NOTIFICATION-TYPE
+ OBJECTS {
+ humiditySensorAvail,
+ trapSeverity,
+ sysName,
+ humiditySensorLabel
+ }
+ STATUS current
+ DESCRIPTION "Remote humidity availability trap"
+ ::= { trapPrefix 11204 }
+
+humiditySensorAvailCLEAR NOTIFICATION-TYPE
+ OBJECTS {
+ humiditySensorAvail,
+ trapSeverity,
+ sysName,
+ humiditySensorLabel
+ }
+ STATUS current
+ DESCRIPTION "Remote humidity availability clear trap"
+ ::= { trapPrefix 21204 }
+
+humiditySensorValueNOTIFY NOTIFICATION-TYPE
+ OBJECTS {
+ humiditySensorValue,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ humiditySensorLabel
+ }
+ STATUS current
+ DESCRIPTION "Remote humidity value trap"
+ ::= { trapPrefix 11205 }
+
+humiditySensorValueCLEAR NOTIFICATION-TYPE
+ OBJECTS {
+ humiditySensorValue,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ humiditySensorLabel
+ }
+ STATUS current
+ DESCRIPTION "Remote humidity value clear trap"
+ ::= { trapPrefix 21205 }
+
+--#####sn2dSensorTable#####--
+
+sn2dSensorAvailNOTIFY NOTIFICATION-TYPE
+ OBJECTS {
+ sn2dSensorAvail,
+ trapSeverity,
+ sysName,
+ sn2dSensorLabel
+ }
+ STATUS current
+ DESCRIPTION "SN-2D availability trap"
+ ::= { trapPrefix 11304 }
+
+sn2dSensorAvailCLEAR NOTIFICATION-TYPE
+ OBJECTS {
+ sn2dSensorAvail,
+ trapSeverity,
+ sysName,
+ sn2dSensorLabel
+ }
+ STATUS current
+ DESCRIPTION "SN-2D availability clear trap"
+ ::= { trapPrefix 21304 }
+
+sn2dSensorDoor1StateNOTIFY NOTIFICATION-TYPE
+ OBJECTS {
+ sn2dSensorDoor1State,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ sn2dSensorLabel,
+ sn2dSensorDoor1Label,
+ sn2dSensorDoor1DisplayState
+ }
+ STATUS current
+ DESCRIPTION "SN-2D Door switch 1 state trap"
+ ::= { trapPrefix 11306 }
+
+sn2dSensorDoor1StateCLEAR NOTIFICATION-TYPE
+ OBJECTS {
+ sn2dSensorDoor1State,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ sn2dSensorLabel,
+ sn2dSensorDoor1Label,
+ sn2dSensorDoor1DisplayState
+ }
+ STATUS current
+ DESCRIPTION "SN-2D Door switch 1 state clear trap"
+ ::= { trapPrefix 21306 }
+
+sn2dSensorDoor2StateNOTIFY NOTIFICATION-TYPE
+ OBJECTS {
+ sn2dSensorDoor2State,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ sn2dSensorLabel,
+ sn2dSensorDoor2Label,
+ sn2dSensorDoor2DisplayState
+ }
+ STATUS current
+ DESCRIPTION "SN-2D Door switch 2 state trap"
+ ::= { trapPrefix 11309 }
+
+sn2dSensorDoor2StateCLEAR NOTIFICATION-TYPE
+ OBJECTS {
+ sn2dSensorDoor2State,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ sn2dSensorLabel,
+ sn2dSensorDoor2Label,
+ sn2dSensorDoor2DisplayState
+ }
+ STATUS current
+ DESCRIPTION "SN-2D Door switch 2 state clear trap"
+ ::= { trapPrefix 21309 }
+
+--#####cooling#####--
+
+--#####vrc#####--
+
+--#####vrcMainTable#####--
+
+vrcMainAvailNOTIFY NOTIFICATION-TYPE
+ OBJECTS {
+ vrcMainAvail,
+ trapSeverity,
+ sysName,
+ vrcMainLabel
+ }
+ STATUS current
+ DESCRIPTION "VRC availability trap"
+ ::= { trapPrefix 13001 }
+
+vrcMainAvailCLEAR NOTIFICATION-TYPE
+ OBJECTS {
+ vrcMainAvail,
+ trapSeverity,
+ sysName,
+ vrcMainLabel
+ }
+ STATUS current
+ DESCRIPTION "VRC availability clear trap"
+ ::= { trapPrefix 23001 }
+
+--#####vrcMainPtTable#####--
+
+--#####vrcMainCfgTable#####--
+
+--#####vrcOutFanPtTable#####--
+
+vrcOutFanPtSpeedNOTIFY NOTIFICATION-TYPE
+ OBJECTS {
+ vrcOutFanPtSpeed,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ vrcMainLabel
+ }
+ STATUS current
+ DESCRIPTION "VRC out-fan speed trap"
+ ::= { trapPrefix 13002 }
+
+vrcOutFanPtSpeedCLEAR NOTIFICATION-TYPE
+ OBJECTS {
+ vrcOutFanPtSpeed,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ vrcMainLabel
+ }
+ STATUS current
+ DESCRIPTION "VRC out-fan speed clear trap"
+ ::= { trapPrefix 23002 }
+
+--#####vrcOutFanCfgTable#####--
+
+--#####vrcInFanPtTable#####--
+
+--#####vrcInFanCfgTable#####--
+
+--#####vrcCompPtTable#####--
+
+vrcCompPtCapacityNOTIFY NOTIFICATION-TYPE
+ OBJECTS {
+ vrcCompPtCapacity,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ vrcMainLabel
+ }
+ STATUS current
+ DESCRIPTION "VRC compressor capacity trap"
+ ::= { trapPrefix 13003 }
+
+vrcCompPtCapacityCLEAR NOTIFICATION-TYPE
+ OBJECTS {
+ vrcCompPtCapacity,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ vrcMainLabel
+ }
+ STATUS current
+ DESCRIPTION "VRC compressor capacity clear trap"
+ ::= { trapPrefix 23003 }
+
+--#####vrcCompCfgTable#####--
+
+--#####vrcReturnPtTable#####--
+
+vrcReturnPtTempNOTIFY NOTIFICATION-TYPE
+ OBJECTS {
+ vrcReturnPtTemp,
+ temperatureUnits,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ vrcMainLabel
+ }
+ STATUS current
+ DESCRIPTION "VRC return temperature trap"
+ ::= { trapPrefix 13004 }
+
+vrcReturnPtTempCLEAR NOTIFICATION-TYPE
+ OBJECTS {
+ vrcReturnPtTemp,
+ temperatureUnits,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ vrcMainLabel
+ }
+ STATUS current
+ DESCRIPTION "VRC return temperature clear trap"
+ ::= { trapPrefix 23004 }
+
+--#####vrcReturnCfgTable#####--
+
+--#####vrcSupplyPtTable#####--
+
+vrcSupplyPtTempNOTIFY NOTIFICATION-TYPE
+ OBJECTS {
+ vrcSupplyPtTemp,
+ temperatureUnits,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ vrcMainLabel
+ }
+ STATUS current
+ DESCRIPTION "VRC supply temperature trap"
+ ::= { trapPrefix 13005 }
+
+vrcSupplyPtTempCLEAR NOTIFICATION-TYPE
+ OBJECTS {
+ vrcSupplyPtTemp,
+ temperatureUnits,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ vrcMainLabel
+ }
+ STATUS current
+ DESCRIPTION "VRC supply temperature clear trap"
+ ::= { trapPrefix 23005 }
+
+--#####vrcSupplyCfgTable#####--
+
+--#####vrcPowerPtTable#####--
+
+vrcPowerPtVoltageNOTIFY NOTIFICATION-TYPE
+ OBJECTS {
+ vrcPowerPtVoltage,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ vrcMainLabel
+ }
+ STATUS current
+ DESCRIPTION "VRC power voltage trap"
+ ::= { trapPrefix 13006 }
+
+vrcPowerPtVoltageCLEAR NOTIFICATION-TYPE
+ OBJECTS {
+ vrcPowerPtVoltage,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ vrcMainLabel
+ }
+ STATUS current
+ DESCRIPTION "VRC power voltage clear trap"
+ ::= { trapPrefix 23006 }
+
+vrcPowerPtFrequencyNOTIFY NOTIFICATION-TYPE
+ OBJECTS {
+ vrcPowerPtFrequency,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ vrcMainLabel
+ }
+ STATUS current
+ DESCRIPTION "VRC power frequency trap"
+ ::= { trapPrefix 13007 }
+
+vrcPowerPtFrequencyCLEAR NOTIFICATION-TYPE
+ OBJECTS {
+ vrcPowerPtFrequency,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ vrcMainLabel
+ }
+ STATUS current
+ DESCRIPTION "VRC power frequency clear trap"
+ ::= { trapPrefix 23007 }
+
+--#####vrcPowerCfgTable#####--
+
+--#####vrcOutdoorPtTable#####--
+
+vrcOutdoorPtTempNOTIFY NOTIFICATION-TYPE
+ OBJECTS {
+ vrcOutdoorPtTemp,
+ temperatureUnits,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ vrcMainLabel
+ }
+ STATUS current
+ DESCRIPTION "VRC outdoor temperature trap"
+ ::= { trapPrefix 13008 }
+
+vrcOutdoorPtTempCLEAR NOTIFICATION-TYPE
+ OBJECTS {
+ vrcOutdoorPtTemp,
+ temperatureUnits,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ vrcMainLabel
+ }
+ STATUS current
+ DESCRIPTION "VRC outdoor temperature clear trap"
+ ::= { trapPrefix 23008 }
+
+--#####vrcDischPtTable#####--
+
+vrcDischPtTempNOTIFY NOTIFICATION-TYPE
+ OBJECTS {
+ vrcDischPtTemp,
+ temperatureUnits,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ vrcMainLabel
+ }
+ STATUS current
+ DESCRIPTION "VRC discharge temperature trap"
+ ::= { trapPrefix 13009 }
+
+vrcDischPtTempCLEAR NOTIFICATION-TYPE
+ OBJECTS {
+ vrcDischPtTemp,
+ temperatureUnits,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ vrcMainLabel
+ }
+ STATUS current
+ DESCRIPTION "VRC discharge temperature clear trap"
+ ::= { trapPrefix 23009 }
+
+vrcDischPtPressureNOTIFY NOTIFICATION-TYPE
+ OBJECTS {
+ vrcDischPtPressure,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ vrcMainLabel
+ }
+ STATUS current
+ DESCRIPTION "VRC discharge pressure trap"
+ ::= { trapPrefix 13010 }
+
+vrcDischPtPressureCLEAR NOTIFICATION-TYPE
+ OBJECTS {
+ vrcDischPtPressure,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ vrcMainLabel
+ }
+ STATUS current
+ DESCRIPTION "VRC discharge pressure clear trap"
+ ::= { trapPrefix 23010 }
+
+--#####vrcDischCfgTable#####--
+
+--#####vrcSuctPtTable#####--
+
+vrcSuctPtTempNOTIFY NOTIFICATION-TYPE
+ OBJECTS {
+ vrcSuctPtTemp,
+ temperatureUnits,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ vrcMainLabel
+ }
+ STATUS current
+ DESCRIPTION "VRC suction temperature trap"
+ ::= { trapPrefix 13011 }
+
+vrcSuctPtTempCLEAR NOTIFICATION-TYPE
+ OBJECTS {
+ vrcSuctPtTemp,
+ temperatureUnits,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ vrcMainLabel
+ }
+ STATUS current
+ DESCRIPTION "VRC suction temperature clear trap"
+ ::= { trapPrefix 23011 }
+
+vrcSuctPtPressureNOTIFY NOTIFICATION-TYPE
+ OBJECTS {
+ vrcSuctPtPressure,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ vrcMainLabel
+ }
+ STATUS current
+ DESCRIPTION "VRC suction pressure trap"
+ ::= { trapPrefix 13012 }
+
+vrcSuctPtPressureCLEAR NOTIFICATION-TYPE
+ OBJECTS {
+ vrcSuctPtPressure,
+ trapThreshType,
+ trapSeverity,
+ sysName,
+ vrcMainLabel
+ }
+ STATUS current
+ DESCRIPTION "VRC suction pressure clear trap"
+ ::= { trapPrefix 23012 }
+
+--#####vrcSuctCfgTable#####--
+
+--###########################################################################################--
+--common group--
+--###########################################################################################--
+
+common OBJECT IDENTIFIER ::= { vertiv 42 }
+
+identity OBJECT IDENTIFIER ::= { common 1 }
+
+i03 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Value given for sysObjectID on IMD3 units"
+ ::= { identity 53 }
+
+r05 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Value given for sysObjectID on R-Series units"
+ ::= { identity 15 }
+
+END