+-- "@(#)fa.mib 00/07/07"
+--
+-- Title: Fibre Alliance Fibre Channel Management Framework Integration MIB
+-- Rev 1.5, June 1, 1999.
+--
+-- Note: This is released for Brocade
+--
+-- Corrected revisionNumber description. last editor on Sept. 09, 2004
+--
+-- added FA MIB last edited on Dec. 18, 2000.
+-- Last edit date: Sept. 09, 2004
+
+FCMGMT-MIB DEFINITIONS ::= BEGIN
+ IMPORTS
+ IpAddress, TimeTicks, experimental
+ FROM RFC1155-SMI
+ OBJECT-TYPE
+ FROM RFC-1212
+ DisplayString
+ FROM RFC1213-MIB
+ TRAP-TYPE
+ FROM RFC-1215;
+
+ --Textual conventions for this MIB
+
+ FcNameId ::= OCTET STRING (SIZE(8))
+
+ FcGlobalId ::= OCTET STRING (SIZE(16))
+
+ FcAddressId ::= OCTET STRING (SIZE(3))
+
+ FcEventSeverity ::= INTEGER {
+ unknown (1),
+ emergency (2),
+ alert (3),
+ critical (4),
+ error (5),
+ warning (6),
+ notify (7),
+ info (8),
+ debug (9),
+ mark (10) -- All messages logged
+ }
+
+ FcUnitType ::= INTEGER {
+ unknown(1),
+ other(2), -- none of the following
+ hub(3), -- passive connectivity unit
+ -- supporting loop protocol.
+ switch(4), -- active connectivity unit
+ -- supporting multiple protocols.
+ gateway(5), -- unit that converts not only
+ -- the interface but also encapsulates
+ -- the frame into another protocol. The
+ -- assumption is that there is always
+ -- two gateways connected together. For
+ -- example, FC <-> ATM.
+ converter(6), -- unit that converts from one
+ -- interface to another. For
+ -- example, FC <-> SCSI.
+ hba(7), -- host bus adapter
+ proxy-agent(8), -- software proxy-agent
+ storage-device(9), -- disk,cd,tape,etc
+ host(10), -- host computer
+ storage-subsystem(11), -- raid, library, etc
+ module(12), -- subcomponent of a system
+ swdriver(13), -- software driver
+ storage-access-device(14), -- Provides storage management
+ -- and access for hetergeneous
+ -- hosts and heterogeneous devices.
+ wdm(15), -- waveform division mutiplexer
+ ups(16) -- uninterruptable power supply
+ }
+
+
+
+
+
+----------------------------------------------------------------------
+ fcmgmt OBJECT IDENTIFIER ::= { experimental 94 }
+
+ -- groups in fcmgmt
+
+ connSet OBJECT IDENTIFIER ::= { fcmgmt 1 }
+ trapReg OBJECT IDENTIFIER ::= { fcmgmt 2 }
+ statSet OBJECT IDENTIFIER ::= { fcmgmt 4 }
+ connUnitServiceSet OBJECT IDENTIFIER ::= { fcmgmt 5 }
+ connUnitServiceScalars OBJECT IDENTIFIER ::= { connUnitServiceSet 1 }
+ connUnitServiceTables OBJECT IDENTIFIER ::= { connUnitServiceSet 2 }
+
+ revisionNumber OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (4))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This is the revision number for this MIB. The
+ format of the revision value is as follows
+ (0) = high order major revision number
+ (1) = low order major revision number
+ (2) = high order minor revision number
+ (3) = low order minor revision number
+ The value will be stored as an ASCII value. The
+ following is the current value of this object.
+ (0) = '0'
+ (1) = '3'
+ (2) = '0'
+ (3) = '0'
+ This defines a revision of 03.00
+ "
+ ::= { fcmgmt 3 }
+
+ -- the connectivity unit group
+
+ -- Implementation of the group is mandatory for all systems.
+
+ uNumber OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of connectivity units present on this
+ system (represented by this agent). May be a count
+ of the boards in a chassis or the number of full boxes
+ in a rack."
+ DEFVAL { 1 }
+ ::= { connSet 1 }
+
+ systemURL OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The top-level URL of the system. If it does not exist
+ the value is empty string. The URL format is
+ implementation dependant and can have keywords embedded
+ that are preceeded by a percent sign (eg, %USER).
+ The following are the defined keywords that will
+ be recognized and replaced with data during a launch.
+ USER - replace with username
+ PASSWORD - replace with password
+ GLOBALID - replace with globalid
+ SERIALNO - replace with serial number
+ "
+ DEFVAL { "" }
+ ::= { connSet 2 }
+
+ statusChangeTime OBJECT-TYPE
+ SYNTAX TimeTicks
+ ACCESS read-only
+ STATUS obsolete
+ DESCRIPTION
+ "The sysuptime timestamp in centiseconds at which
+ the last status change occurred for any members of
+ the set."
+ ::= { connSet 3 }
+
+ configurationChangeTime OBJECT-TYPE
+ SYNTAX TimeTicks
+ ACCESS read-only
+ STATUS obsolete
+ DESCRIPTION
+ "The sysuptime timestamp in centiseconds at which
+ the last configuration change occurred for any
+ members of the set. This represents a union of change
+ information for connUnitConfigurationChangeTime."
+ ::= { connSet 4 }
+
+ connUnitTableChangeTime OBJECT-TYPE
+ SYNTAX TimeTicks
+ ACCESS read-only
+ STATUS obsolete
+ DESCRIPTION
+ "The sysuptime timestamp in centiseconds at which
+ the connUnitTable was updated (an entry was either
+ added or deleted."
+ ::= { connSet 5 }
+
+ -- The Connectivity table contains general information on the
+ -- system's units.
+ connUnitTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ConnUnitEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of units under a single SNMP agent. The number
+ of entries is given by the value of uNumber. It is 1
+ for stand-alone system."
+ ::= { connSet 6 }
+
+ connUnitEntry OBJECT-TYPE
+ SYNTAX ConnUnitEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A connectivity unit entry containing objects for a
+ particular unit."
+ INDEX { connUnitId }
+ ::= { connUnitTable 1 }
+
+ ConnUnitEntry ::=
+ SEQUENCE {
+ connUnitId
+ OCTET STRING,
+ connUnitGlobalId
+ FcGlobalId,
+ connUnitType
+ FcUnitType,
+ connUnitNumports
+ INTEGER,
+ connUnitState
+ INTEGER,
+ connUnitStatus
+ INTEGER,
+ connUnitProduct
+ DisplayString,
+ connUnitSn
+ DisplayString,
+ connUnitUpTime
+ TimeTicks,
+ connUnitUrl
+ DisplayString,
+ connUnitDomainId
+ OCTET STRING,
+ connUnitProxyMaster
+ INTEGER,
+ connUnitPrincipal
+ INTEGER,
+ connUnitNumSensors
+ INTEGER,
+ connUnitStatusChangeTime
+ TimeTicks,
+ connUnitConfigurationChangeTime
+ TimeTicks,
+ connUnitNumRevs
+ INTEGER,
+ connUnitNumZones
+ INTEGER,
+ connUnitModuleId
+ OCTET STRING,
+ connUnitName
+ DisplayString,
+ connUnitInfo
+ DisplayString,
+ connUnitControl
+ INTEGER,
+ connUnitContact
+ DisplayString,
+ connUnitLocation
+ DisplayString,
+ connUnitEventFilter
+ FcEventSeverity,
+ connUnitNumEvents
+ INTEGER,
+ connUnitMaxEvents
+ INTEGER,
+ connUnitEventCurrID
+ INTEGER
+ }
+
+ connUnitId OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (16))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The unique identification for this connectivity unit
+ among those within this proxy domain.
+ The value MUST be unique within the proxy domain
+ because it is the index variable for connUnitTable.
+ The value assigned to a given conectivity unit
+ SHOULD be persistent across agent and unit resets.
+ It SHOULD be the same as connUnitGlobalId
+ if connUnitGlobalId is known and stable."
+ ::= { connUnitEntry 1 }
+
+ connUnitGlobalId OBJECT-TYPE
+ SYNTAX FcGlobalId
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "An optional global-scope identifier for this connectivity unit.
+ It MUST be a WWN for this connectivity unit
+ or 16 octets of value zero.
+ WWN formats requiring fewer than 16 octets
+ MUST be extended to 16 octets with trailing zero octets,
+ If a WWN is used for connUnitId,
+ the same WWN MUST be used for connUnitGlobalId.
+ When a non-zero value is provided,
+ it SHOULD be persistent across agent and unit resets.
+ It SHOULD be globally unique.
+ It SHOULD be one of these FC-PH/PH3 formats:
+ IEEE (NAA=1)
+ IEEE Extended (NAA=2)
+ IEEE Registered (NAA=5).
+ IEEE Registered extended (NAA=6).
+
+ Use of the IEEE formats allows any IEEE-registered vendor
+ to assure global uniqueness independently.
+ The following are some references on IEEE WWN formats:
+ http://standards.ieee.org/regauth/oui/tutorials/fibreformat.html
+ http://standards.ieee.org/regauth/oui/tutorials/fibrecomp_id.html
+
+ If one or more WWNs are associated with the connUnit
+ via other management methods,
+ one of them SHOULD be used for connUnitGlobalId.
+ If there is not a WWN assigned specifically to the connUnit,
+ there is some merit, though not a requirement,
+ to using a WWN assigned to (one of)
+ its permanently attached FC/LAN interface(s).
+ This can not risk uniqueness, though.
+ As a counterexample, if your
+ agent runs in a host and the host has an HBA,
+ it is quite possible that agent, host, and HBA
+ will all be distinct connUnits, so the host
+ and agent can not use the WWN of the HBA.
+ Another example:
+ If your hub has a built-in Ethernet port, it
+ might be reasonable for the hub to use its LAN
+ address (prefixed with the appropriate
+ NAA) as its connUnitId. But if the
+ Ethernet were a replaceable PCCard, the hub
+ should have an independent ID."
+ ::= { connUnitEntry 2 }
+
+ connUnitType OBJECT-TYPE
+ SYNTAX FcUnitType
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The type of this connectivity unit."
+ ::= { connUnitEntry 3 }
+
+
+ connUnitNumports OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Number of physical ports in the connectivity unit
+ (internal/embedded, external)."
+ ::= { connUnitEntry 4 }
+
+ connUnitState OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(1),
+ online(2),
+ offline(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Overall state of the connectivity unit."
+ ::= { connUnitEntry 5 }
+
+ connUnitStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(1),
+ unused(2),
+ ok(3),
+ warning(4), -- needs attention
+ failed(5)
+ }
+ ACCESS read-only
+ STATUS mandatory
+
+ DESCRIPTION
+ "Overall status of the connectivity unit."
+ ::= { connUnitEntry 6 }
+
+ connUnitProduct OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..79))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The connectivity unit vendor's product
+ model name."
+ ::= { connUnitEntry 7 }
+
+ connUnitSn OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..79))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The serial number for this connectivity unit."
+ ::= { connUnitEntry 8 }
+
+ connUnitUpTime OBJECT-TYPE
+ SYNTAX TimeTicks
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of centiseconds since the
+ last unit initialization."
+ ::= { connUnitEntry 9 }
+
+ connUnitUrl OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "URL to launch a management application,
+ if applicable. Otherwise empty string.
+ In a standalone unit, this would be the
+ same as the top-level URL. This has the same
+ definition as systemURL for keywords."
+ ::= { connUnitEntry 10 }
+
+ connUnitDomainId OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(3))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "24 bit Fibre Channel address ID of this
+ connectivity unit, right justified with leading
+ zero's if required. This should be set to the
+ Fibre Channel address ID or if it is a switch
+ it would be set to the Domain Controller address.
+ If this value is not applicable,
+ return all bits set to one."
+ ::= { connUnitEntry 11 }
+
+ connUnitProxyMaster OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(1),
+ no(2),
+ yes(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A value of 'yes' means this is the proxy master
+ unit for a set of managed units. For example,
+ this could be the only unit with a management
+ card in it for a set of units. A standalone unit
+ should return 'yes' for this object."
+ ::= { connUnitEntry 12 }
+
+ connUnitPrincipal OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(1),
+ no(2),
+ yes(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Whether this connectivity unit is the principal unit
+ within the group of fabric elements. If this value
+ is not applicable, return unknown."
+ ::= { connUnitEntry 13 }
+
+ connUnitNumSensors OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Number of sensors in the connUnitSensorTable."
+ ::= { connUnitEntry 14 }
+
+ connUnitStatusChangeTime OBJECT-TYPE
+ SYNTAX TimeTicks
+ ACCESS read-only
+ STATUS obsolete
+ DESCRIPTION
+ "The sysuptime timestamp in centiseconds
+ at which the last status change occurred."
+ ::= { connUnitEntry 15 }
+
+ connUnitConfigurationChangeTime OBJECT-TYPE
+ SYNTAX TimeTicks
+ ACCESS read-only
+ STATUS obsolete
+ DESCRIPTION
+ "The sysuptime timestamp in centiseconds
+ at which the last configuration change
+ occurred."
+ ::= { connUnitEntry 16 }
+
+ connUnitNumRevs OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of revisions in the connUnitRevsTable."
+ DEFVAL { 1 }
+ ::= { connUnitEntry 17 }
+
+ connUnitNumZones OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS obsolete
+ DESCRIPTION
+ "Number of zones defined in connUnitZoneTable."
+ ::= { connUnitEntry 18 }
+
+ connUnitModuleId OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(16))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This is a unique id, persistent between boots,
+ that can be used to group a set of connUnits
+ together into a module. The intended use would
+ be to create a connUnit with a connUnitType of
+ 'module' to represent a physical or logical
+ group of connectivity units. Then the value
+ of the group would be set to the value of
+ connUnitId for this 'container' connUnit.
+ connUnitModuleId should be zeros if this
+ connUnit is not part of a module."
+ ::= { connUnitEntry 19 }
+
+ connUnitName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..79))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A display string containing a name for this
+ connectivity unit. This object value should be
+ persistent between boots."
+ ::= { connUnitEntry 20 }
+
+ connUnitInfo OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A display string containing information
+ about this connectivity unit. This object value
+ should be persistent between boots."
+ ::= { connUnitEntry 21 }
+
+ connUnitControl OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(1),
+ invalid(2),
+ resetConnUnitColdStart(3),
+ resetConnUnitWarmStart(4),
+ offlineConnUnit(5),
+ onlineConnUnit(6)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This object is used to control the addressed
+ connUnit.
+
+ NOTE: 'Cold Start' and 'Warm Start'
+ are as defined in MIB II and are not meant
+ to be a factory reset.
+
+ resetConnUnitColdStart:
+ the addressed unit performs
+ a 'Cold Start' reset.
+
+ resetConnUnitWarmStart:
+ the addressed unit performs
+ a 'Warm Start' reset.
+
+ offlineConnUnit:
+ the addressed unit puts itself into
+ an implementation dependant 'offline' state.
+ In general,if a unit is in an offline state,
+ it cannot be used to perform meaningful
+ Fibre Channel work.
+
+ onlineConnUnit:
+ the addressed unit puts itself into an
+ implementation dependant 'online' state.
+ In general, if a unit is in an online state,
+ it is capable of performing meaningful
+ Fibre Channel work.
+
+ NOTE: Each implementation may chose not to allow
+ any or all of these values on a SET. "
+
+ ::= { connUnitEntry 22 }
+
+ connUnitContact OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..79))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Contact information for this connectivity
+ unit."
+ ::= { connUnitEntry 23 }
+
+ connUnitLocation OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..79))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Location information for this connectivity
+ unit."
+ ::= { connUnitEntry 24 }
+
+ connUnitEventFilter OBJECT-TYPE
+ SYNTAX FcEventSeverity
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This value defines the event severity
+ that will be logged by this connectivity unit.
+ All events of severity less than or equal to
+ connUnitEventFilter are logged in connUnitEventTable."
+ ::= { connUnitEntry 25 }
+
+ connUnitNumEvents OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Number of events currently in the
+ connUnitEventTable."
+ ::= { connUnitEntry 26 }
+
+ connUnitMaxEvents OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Max number of events that can be defined
+ in connUnitEventTable."
+ ::= { connUnitEntry 27 }
+
+ connUnitEventCurrID OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The last used event id (connUnitEventId)."
+ ::= { connUnitEntry 28 }
+
+
+------------------------------------------------------------------
+-- The Table of revisions for hardware and software elements.
+
+ connUnitRevsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ConnUnitRevsEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Table of the revisions supported by
+ connectivity units managed by this agent."
+ ::= { connSet 7 }
+
+ connUnitRevsEntry OBJECT-TYPE
+ SYNTAX ConnUnitRevsEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ ""
+ INDEX { connUnitRevsUnitId,
+ connUnitRevsIndex }
+ ::= { connUnitRevsTable 1 }
+
+ ConnUnitRevsEntry ::=
+ SEQUENCE {
+ connUnitRevsUnitId
+ OCTET STRING,
+ connUnitRevsIndex
+ INTEGER,
+ connUnitRevsRevId
+ DisplayString,
+ connUnitRevsDescription
+ DisplayString }
+
+ connUnitRevsUnitId OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (16))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The connUnitId of the connectivity unit
+ that contains this revision table."
+ ::= { connUnitRevsEntry 1 }
+
+ connUnitRevsIndex OBJECT-TYPE
+ SYNTAX INTEGER (1..2147483647)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A unique value among all connUnitRevsEntrys
+ with the same value of connUnitRevsUnitId,
+ in the range between 1 and
+ connUnitNumRevs[connUnitRevsUnitId]."
+ ::= { connUnitRevsEntry 2 }
+
+ connUnitRevsRevId OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A vendor-specific string identifying a
+ revision of a component of the connUnit
+ indexed by connUnitRevsUnitId."
+ ::= { connUnitRevsEntry 3 }
+
+ connUnitRevsDescription OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Description of a component to which the revision
+ corresponds."
+ ::= { connUnitRevsEntry 4 }
+
+-----------------------------------------------------------------------
+-- The Sensor table
+
+ connUnitSensorTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ConnUnitSensorEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Table of the sensors supported by each
+ connectivity unit managed by this agent."
+ ::= { connSet 8 }
+
+ connUnitSensorEntry OBJECT-TYPE
+ SYNTAX ConnUnitSensorEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Each entry contains the information for a
+ specific sensor."
+ INDEX { connUnitSensorUnitId,
+ connUnitSensorIndex }
+ ::= { connUnitSensorTable 1 }
+
+ ConnUnitSensorEntry ::=
+ SEQUENCE {
+ connUnitSensorUnitId
+ OCTET STRING,
+ connUnitSensorIndex
+ INTEGER,
+ connUnitSensorName
+ DisplayString,
+ connUnitSensorStatus
+ INTEGER,
+ connUnitSensorInfo
+ DisplayString,
+ connUnitSensorMessage
+ DisplayString,
+ connUnitSensorType
+ INTEGER,
+ connUnitSensorCharacteristic
+ INTEGER
+ }
+
+ connUnitSensorUnitId OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (16))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The connUnitId of the connectivity unit
+ that contains this sensor table."
+ ::= { connUnitSensorEntry 1 }
+
+ connUnitSensorIndex OBJECT-TYPE
+ SYNTAX INTEGER (1..2147483647)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A unique value among all connUnitSensorEntrys
+ with the same value of connUnitSensorUnitId,
+ in the range between 1 and
+ connUnitNumSensor[connUnitSensorUnitId]."
+ ::= { connUnitSensorEntry 2}
+
+ connUnitSensorName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A textual identification of the sensor
+ intended primarily for operator use."
+ ::= { connUnitSensorEntry 3 }
+
+ connUnitSensorStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(1),
+ other(2),
+ ok(3), -- the sensor indicates ok
+ warning(4), -- the sensor indicates a warning
+ failed(5) -- the sensor indicates failure
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The status indicated by the sensor."
+ ::= { connUnitSensorEntry 4 }
+
+ connUnitSensorInfo OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Miscellaneous static info about the sensor
+ such as its serial number."
+ ::= { connUnitSensorEntry 5 }
+
+ connUnitSensorMessage OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This describes the status of the sensor
+ as a message. It may also provide more
+ resolution on the sensor indication, for
+ example 'Cover temperature 1503K, above
+ nominal operating range'"
+ ::= { connUnitSensorEntry 6 }
+
+ connUnitSensorType OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(1),
+ other(2),
+ battery(3),
+ fan(4),
+ power-supply(5),
+ transmitter(6),
+ enclosure(7),
+ board(8),
+ receiver(9)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The type of component being monitored by this
+ sensor."
+ ::= { connUnitSensorEntry 7 }
+
+ connUnitSensorCharacteristic OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(1),
+ other(2),
+ temperature(3),
+ pressure(4),
+ emf(5),
+ currentValue(6), -- current is a keyword
+ airflow(7),
+ frequency(8),
+ power(9),
+ door(10)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The characteristics being monitored by this
+ sensor."
+ ::= { connUnitSensorEntry 8 }
+
+-----------------------------------------------------------------------
+-- The port table
+
+ connUnitPortTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ConnUnitPortEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Generic information on ports for a specific
+ connUnit."
+ ::= { connSet 10 }
+
+ connUnitPortEntry OBJECT-TYPE
+ SYNTAX ConnUnitPortEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Each entry contains the information for
+ a specific port."
+ INDEX { connUnitPortUnitId,
+ connUnitPortIndex }
+ ::= { connUnitPortTable 1 }
+
+ ConnUnitPortEntry ::=
+ SEQUENCE {
+ connUnitPortUnitId
+ OCTET STRING,
+ connUnitPortIndex
+ INTEGER,
+ connUnitPortType
+ INTEGER,
+ connUnitPortFCClassCap
+ OCTET STRING,
+ connUnitPortFCClassOp
+ OCTET STRING,
+ connUnitPortState
+ INTEGER,
+ connUnitPortStatus
+ INTEGER,
+ connUnitPortTransmitterType
+ INTEGER,
+ connUnitPortModuleType
+ INTEGER,
+ connUnitPortWwn
+ FcNameId,
+ connUnitPortFCId
+ OCTET STRING,
+ connUnitPortSn
+ DisplayString,
+ connUnitPortRevision
+ DisplayString,
+ connUnitPortVendor
+ DisplayString,
+ connUnitPortSpeed
+ INTEGER,
+ connUnitPortControl
+ INTEGER,
+ connUnitPortName
+ DisplayString,
+ connUnitPortPhysicalNumber
+ INTEGER,
+ connUnitPortStatObject
+ OBJECT IDENTIFIER,
+ connUnitPortProtocolCap
+ OCTET STRING,
+ connUnitPortProtocolOp
+ OCTET STRING,
+ connUnitPortNodeWwn
+ FcNameId,
+ connUnitPortHWState
+ INTEGER
+ }
+
+ connUnitPortUnitId OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (16))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The connUnitId of the connectivity unit
+ that contains this port."
+ ::= { connUnitPortEntry 1 }
+
+ connUnitPortIndex OBJECT-TYPE
+ SYNTAX INTEGER (1..2147483647)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A unique value among all connUnitPortEntrys
+ on this connectivity unit, between 0 and
+ connUnitNumPort[connUnitPortUnitId]."
+ ::= { connUnitPortEntry 2 }
+
+ connUnitPortType OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown (1),
+ other (2),
+ not-present (3),
+ hub-port (4),
+ n-port (5), -- end port for fabric
+ l-port (6), -- end port for loop
+ fl-port (7), -- public loop
+ f-port (8), -- fabric port
+ e-port (9), -- fabric expansion port
+ g-port (10), -- generic fabric port
+ domain-ctl (11), -- domain controller
+ hub-controller(12),
+ scsi (13), -- parallel SCSI port
+ escon (14),
+ lan (15),
+ wan (16),
+ ac (17), -- AC power line
+ dc (18), -- DC power line
+ ssa (19) -- serial storage architecture
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The port type."
+ ::= { connUnitPortEntry 3 }
+
+ connUnitPortFCClassCap OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (2))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Bit mask that specifies the classes
+ of service capability of this port. If this is not
+ applicable, return all bits set to zero.
+
+ The bits have
+ the following definition:
+ unknown - 0
+ class-f - 1
+ class-one - 2
+ class-two - 4
+ class-three - 8
+ class-four - 16
+ class-five - 32
+ class-six - 64"
+ ::= { connUnitPortEntry 4 }
+
+ connUnitPortFCClassOp OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (2))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Bit mask that specifies the classes
+ of service that are currently operational.
+ If this is not applicable, return all bits
+ set to zero. This object has the same
+ definition as connUnitPortFCClassCap"
+ ::= { connUnitPortEntry 5 }
+
+ connUnitPortState OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(1),
+ online(2), -- available for meaningful work
+ offline(3), -- not available for meaningful work
+ bypassed(4), -- no longer used (4/12/00)
+ diagnostics(5)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The user selected state of the port hardware."
+ ::= { connUnitPortEntry 6 }
+
+ connUnitPortStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown (1),
+ unused (2), -- device cannot report this status
+ ready (3), -- FCAL Loop or FCPH Link reset protocol
+ -- initialization has completed
+ warning (4), -- do not use (4/12/00)
+ failure (5), -- do not use (4/12/00)
+ notparticipating (6), -- loop notparticipating and does not
+ -- have a loop address
+ initializing (7), -- protocol is proceeding
+ bypass (8), -- do not use (4/12/00)
+ ols (9) -- FCP offline status
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "An overall protocol status for the
+ port. This value of connUnitPortState is not
+ online, then this is reported Unknown."
+ ::= { connUnitPortEntry 7 }
+
+ connUnitPortTransmitterType OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(1),
+ other(2),
+ unused(3),
+ shortwave(4),
+ longwave(5),
+ copper(6),
+ scsi(7),
+ longwaveNoOFC(8),
+ shortwaveNoOFC(9),
+ longwaveLED(10),
+ ssa(11)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The technology of the port transceiver."
+ ::= { connUnitPortEntry 8 }
+
+ connUnitPortModuleType OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(1),
+ other(2),
+ gbic(3),
+ embedded(4), -- fixed, ie, oneXnine
+ glm(5),
+ gbicSerialId(6),
+ gbicNoSerialId(7),
+ gbicNotInstalled(8),
+ smallFormFactor(9)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The module type of the port connector."
+ ::= { connUnitPortEntry 9 }
+
+ connUnitPortWwn OBJECT-TYPE
+ SYNTAX FcNameId
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The World Wide Name of the port
+ if applicable, otherwise empty string."
+ ::= { connUnitPortEntry 10 }
+
+ connUnitPortFCId OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(3))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This is the assigned Fibre Channel ID of
+ this port. This value is expected to be
+ a Big Endian value of 24 bits. If this is
+ loop, then it is the ALPA that is connected.
+ If this is an eport, then it will only
+ contain the domain ID left justified, zero
+ filled. If this port does not have a Fibre
+ Channel address, return all bits set to 1."
+ ::= { connUnitPortEntry 11 }
+
+ connUnitPortSn OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..79))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The serial number of the unit (e.g., for
+ a GBIC). If this is not applicable, return
+ empty string."
+ ::= { connUnitPortEntry 12 }
+
+ connUnitPortRevision OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..79))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The port revision (e.g., for a GBIC)."
+ ::= { connUnitPortEntry 13 }
+
+ connUnitPortVendor OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..79))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The port vendor (e.g., for a GBIC)."
+ ::= { connUnitPortEntry 14 }
+
+ connUnitPortSpeed OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The speed of the port in kilobytes per
+ second."
+ ::= { connUnitPortEntry 15 }
+
+ connUnitPortControl OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(1),
+ invalid(2),
+ resetConnUnitPort(3),
+ bypassConnUnitPort(4),
+ unbypassConnUnitPort(5),
+ offlineConnUnitPort(6),
+ onlineConnUnitPort(7),
+ resetConnUnitPortCounters(8)
+ }
+ ACCESS read-write -- (or maybe write-only)
+ STATUS mandatory
+ DESCRIPTION
+ "This object is used to control the addressed
+ connUnit's port. Valid commands are:
+
+ resetConnUnitPort: If the addressed connUnit
+ allows this operation to be performed to this
+ port, the addressed port performs a
+ vendor-specific 'reset' operation. Examples of
+ these operations are: the Link Reset protocol,
+ the Loop Initialization protocol, or a
+ resynchronization occurring between the
+ transceiver in the addressed port to the
+ transceiver that the port is connected to.
+
+ bypassConnUnitPort: If the addressed connUnit
+ allows this operation to be performed to this
+ port, the addressed port performs a
+ vendor-specific 'bypass' operation. Examples of
+ these operations are:
+ transitioning from online to offline, a
+ request(NON-PARTICIPATING) command to the
+ Loop Port state machine, or removal of the
+ port from an arbitrated loop by a hub.
+
+ unbypassConnUnitPort: If the addressed connUnit
+ allows this operation to be performed to this
+ port, the addressed port performs a
+ vendor-specific 'unbypass' operation. Examples
+ of these operations are:
+ the Link Failure protocol, a
+ request(PARTICIPATING) command to the
+ Loop Port state machine, or addition of the
+ port to an arbitrated loop by a hub.
+
+ offlineConnUnitPort: If the addressed connUnit
+ allows this operation to be performed to this
+ port, the addressed port performs a
+ vendor-specific 'offline' operation. Examples
+ of these operations are:
+ disabling a port's transceiver, the Link
+ Failure protocol, request(NON-PARTICIPATING)
+ command to the Loop Port state machine, or
+ removal of the port from an arbitrated loop
+ by a hub.
+
+ onlineConnUnitPort: If the addressed connUnit
+ allows this operation to be performed to this
+ port, the addressed port performs a
+ vendor-specific 'online' operation. Examples
+ of these operations are:
+ enabling a port's transceiver, the Link
+ Failure protocol, request(PARTICIPATING)
+ command to the Loop Port state machine, or
+ addition of the port from an arbitrated loop
+ by a hub.
+
+ NOTE: Each implementation may chose not to allow
+ any or all of these values on a SET. "
+
+ ::= { connUnitPortEntry 16 }
+
+ connUnitPortName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A string describing the addressed port."
+ ::= { connUnitPortEntry 17 }
+
+ connUnitPortPhysicalNumber OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This is the internal port number this
+ port is known by. In many implementations,
+ this should be the same as connUnitPortIndex.
+ Some implementations may have an internal port
+ representation not compatible with the rules
+ for table indeces. In that case, provide the
+ internal representation of this port in this
+ object. This value may also be used in the
+ connUnitLinkPortNumberX or connUnitLinkPortNumberY
+ objects of the connUnitLinkTable."
+ ::= { connUnitPortEntry 18 }
+
+ connUnitPortStatObject OBJECT-TYPE
+ SYNTAX OBJECT IDENTIFIER
+ ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "This contains the OID of the first object of the
+ table that contains the statistics for this particular
+ port. If this has a value of zero, then there are no
+ statistics available for this port. The port type
+ information will help identify the statistics objects
+ that will be found in the table. From this point, one
+ would do a getnext to get the next statistics object.
+ When the first part of the OID changes, the end of
+ table is reached."
+ ::= { connUnitPortEntry 19 }
+
+ connUnitPortProtocolCap OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (2))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Bit mask that specifies the driver level
+ protocol capability of this port. If this is not
+ applicable, return all bits set to zero.
+
+ The bits have
+ the following definition:
+ unknown - 0
+ Loop - 1
+ Fabric - 2
+ SCSI - 4
+ TCP/IP - 8
+ VI - 16
+ FICON - 32"
+ ::= { connUnitPortEntry 20 }
+
+ connUnitPortProtocolOp OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (2))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Bit mask that specifies the driver level
+ protocol(s) that are currently operational.
+ If this is not applicable, return all bits
+ set to zero. This object has the same
+ definition as connUnitPortProtocolCap"
+ ::= { connUnitPortEntry 21 }
+
+ connUnitPortNodeWwn OBJECT-TYPE
+ SYNTAX FcNameId
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The Node World Wide Name of the port
+ if applicable, otherwise all zeros.
+ This should have the same value for a
+ group of related ports. The container is
+ defined as the largest physical entity.
+ For example, all ports on HBAs on a host
+ will have the same Node WWN. All ports on
+ the same storage subsystem will have the
+ same Node WWN."
+ ::= { connUnitPortEntry 22 }
+
+ connUnitPortHWState OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown (1),
+ failed (2), -- port failed diagnostics
+ bypassed (3), -- FCAL bypass, loop only
+ active (4), -- connected to a device
+ loopback (5), -- Port in ext loopback
+ txfault (6), -- Transmitter fault
+ noMedia (7), -- media not installed
+ linkDown (8) -- waiting for activity (rx sync)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The hardware detected state of the port."
+ ::= { connUnitPortEntry 23 }
+
+
+-----------------------------------------------------------------------
+-- event group
+
+ connUnitEventTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ConnUnitEventEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The table of connectivity unit events. Errors,
+ warnings, and information should be reported
+ in this table."
+ ::= { connSet 11 }
+
+ connUnitEventEntry OBJECT-TYPE
+ SYNTAX ConnUnitEventEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Each entry contains information on
+ a specific event for the given
+ connectivity unit."
+ INDEX { connUnitEventUnitId, connUnitEventIndex }
+ ::= { connUnitEventTable 1 }
+
+ ConnUnitEventEntry ::=
+ SEQUENCE {
+ connUnitEventUnitId
+ OCTET STRING,
+ connUnitEventIndex
+ INTEGER,
+ connUnitEventId
+ INTEGER,
+ connUnitREventTime
+ DisplayString,
+ connUnitSEventTime
+ TimeTicks,
+ connUnitEventSeverity
+ FcEventSeverity,
+ connUnitEventType
+ INTEGER,
+ connUnitEventObject
+ OBJECT IDENTIFIER,
+ connUnitEventDescr
+ DisplayString
+ }
+
+ connUnitEventUnitId OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (16))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The connUnitId of the connectivity unit
+ that contains this event table."
+ ::= { connUnitEventEntry 1 }
+
+ connUnitEventIndex OBJECT-TYPE
+ SYNTAX INTEGER (1..2147483647)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Each connectivity unit has its own event buffer.
+ As it wraps, it may write over previous events.
+ This object is an index into the buffer.
+ It is recommended that this table be read using
+ 'getNext's to retrieve the initial table.
+ The management application should read the
+ event table at periodic intervals and then
+ determine if any new entries were added by
+ comparing the last known index value with the
+ current highest index value. The management
+ application should then update its copy of
+ the event table. If the read interval
+ is too long, it is possible that there may
+ be events that may not be contained in the
+ agent's internal event buffer.
+ For example, an agent may read events 50-75.
+ At the next read interval, connUnitEventCurrID
+ is 189. If the management app tries to read
+ event index 76, and the agent's internal buffer
+ is 100 entries max, event index 76 will no longer
+ be available.
+ The index value is an incrementing integer starting
+ from one every time there is a table reset.
+ On table reset, all contents are emptied and
+ all indeces are set to zero. When an
+ event is added to the table, the event is
+ assigned the next higher integer value than
+ the last item entered into the table. If the
+ index value reaches its maximum value, the next
+ item entered will cause the index value to
+ roll over and start at one again."
+ ::= { connUnitEventEntry 2 }
+
+ connUnitEventId OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS obsolete
+ DESCRIPTION
+ "The internal event Id. Incremented for each
+ event, ranging between 0 and connUnitMaxEvents.
+ Not used as table index to simplify
+ the agent implementation. When this
+ reaches the end of the range specified by
+ connUnitMaxEvents, the Id will roll over to start
+ at zero. This value will be set back to zero at
+ reset. The relationship of this value to the index
+ is that internal event id may represent a smaller
+ number than a 32 bit integer (eg max 100 entries)
+ and would only have a value range up to
+ connUnitMaxEvents."
+ ::= { connUnitEventEntry 3 }
+
+ connUnitREventTime OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (15))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This is the real time when the event occurred.
+ It has the following format.
+ DDMMYYYY HHMMSS
+ DD=day number
+ MM=month number
+ YYYY=year number
+ HH=hour number
+ MM=minute number
+ SS=seconds number
+ If not applicable, return a NULL string."
+ ::= { connUnitEventEntry 4 }
+
+ connUnitSEventTime OBJECT-TYPE
+ SYNTAX TimeTicks
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This is the sysuptime timestamp when the
+ event occurred."
+ ::= { connUnitEventEntry 5 }
+
+ connUnitEventSeverity OBJECT-TYPE
+ SYNTAX FcEventSeverity
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The event severity level."
+ ::= { connUnitEventEntry 6 }
+
+ connUnitEventType OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(1),
+ other(2),
+ status(3),
+ configuration(4),
+ topology(5)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The type of this event."
+ ::= { connUnitEventEntry 7 }
+
+ connUnitEventObject OBJECT-TYPE
+ SYNTAX OBJECT IDENTIFIER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This is used with the connUnitEventType
+ to identify which object the event refers to.
+ It can be the OID of a connectivity unit or of
+ another object like connUnitPortStatus[...]"
+ ::= { connUnitEventEntry 8 }
+
+ connUnitEventDescr OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The description of the event."
+ ::= { connUnitEventEntry 9 }
+
+-- The link table
+-- is intended to organize and communicate
+-- any information the agent possesses
+-- which would assist a management application
+-- to discover the CONNECTIVITY UNITS in the
+-- framework and the TOPOLOGY of their interconnect.
+-- That is, the goal is to assist the management
+-- application not only to LIST the elements of the framework,
+-- but to MAP them.
+
+-- With this goal, the agent SHOULD include
+-- as much as it possesses about any links
+-- from its own connectivity units to others,
+-- including links among its own units.
+
+-- An agent SHOULD include partial information
+-- about links if it is not able to fully
+-- define them in accord with the following structure;
+-- however, the information MUST include either
+-- a nonzero connUnitNodeId- or a nonzero connUnitPortWwn-
+-- for each end of the link.
+
+-- If the agent is able to discover links
+-- which do not directly attach to members of its agency
+-- and its discovery algorithm gives some assurance
+-- the links are recently valid, it MAY include these links.
+
+-- Link information entered by administrative action
+-- MAY be included even if not validated directly
+-- if the link has at least one endpoint in this agency,
+-- but SHOULD NOT be included otherwise.
+
+-- A connectivity unit should fill the table in as best it can.
+-- One of the methods to fill this in would be to use the RNID
+-- ELS (ANSI document 99-422v0). This allows one to query a
+-- port for the information needed for the link table.
+
+-- This table is accessed either directly if the management
+-- software has an index value or via GetNexts. The value of
+-- the indexes are not required to be contiguous. Each entry
+-- created in this table will be assigned an index. This
+-- relationship is kept persistent until the entry is removed
+-- from the table or the system is reset. The total number of
+-- entries are defined by the size of the table
+
+-- For an entry to be considered to be valid, both the X (local)
+-- and the Y (remote) need to have one valid value.
+
+ connUnitLinkTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ConnUnitLinkEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of links know to this agent from this
+ connectivity unit to other connectivity units."
+ ::= { connSet 12 }
+
+ connUnitLinkEntry OBJECT-TYPE
+ SYNTAX ConnUnitLinkEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "An entry describing a particular link to another."
+ INDEX { connUnitLinkUnitId,
+ connUnitLinkIndex }
+ ::= { connUnitLinkTable 1 }
+
+ ConnUnitLinkEntry ::=
+ SEQUENCE {
+ connUnitLinkUnitId
+ OCTET STRING,
+ connUnitLinkIndex
+ INTEGER,
+ connUnitLinkNodeIdX
+ OCTET STRING,
+ connUnitLinkPortNumberX
+ INTEGER,
+ connUnitLinkPortWwnX
+ OCTET STRING,
+ connUnitLinkNodeIdY
+ OCTET STRING,
+ connUnitLinkPortNumberY
+ INTEGER,
+ connUnitLinkPortWwnY
+ OCTET STRING,
+ connUnitLinkAgentAddressY
+ OCTET STRING,
+ connUnitLinkAgentAddressTypeY
+ INTEGER,
+ connUnitLinkAgentPortY
+ INTEGER,
+ connUnitLinkUnitTypeY
+ FcUnitType,
+ connUnitLinkConnIdY
+ OCTET STRING,
+ connUnitLinkCurrIndex
+ INTEGER
+ }
+
+ connUnitLinkUnitId OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (16))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The connUnitId of the connectivity unit
+ that contains this link table."
+ ::= { connUnitLinkEntry 1 }
+
+ connUnitLinkIndex OBJECT-TYPE
+ SYNTAX INTEGER (0..2147483647)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This value is used to create a unique value
+ for each entry in the link table with the same
+ connUnitLinkUnitId. The value
+ can only be reused if it is not currently in
+ in use and the value is the next candidate to
+ be used. This value is allowed to wrap at the
+ highest value represented by the number of bits.
+ This value is reset to zero when the system is
+ Reset and the first value to be used is one."
+ ::= { connUnitLinkEntry 2 }
+
+ connUnitLinkNodeIdX OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(64))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The node WWN of the unit at one end
+ of the link. If the node WWN is unknown
+ and the node is a connUnit in the responding
+ agent then the value of this object MUST BE
+ equal to its connUnitID."
+ ::= { connUnitLinkEntry 3 }
+
+ connUnitLinkPortNumberX OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The port number on the unit specified by
+ connUnitLinkNodeIdX if known, otherwise -1.
+ If the value is nonnegative then it will be
+ equal to connUnitPortPhysicalNumber."
+ ::= { connUnitLinkEntry 4 }
+
+ connUnitLinkPortWwnX OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(16))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The port WWN of the unit specified by
+ connUnitLinkNodeIdX if known,
+ otherwise 16 octets of binary 0"
+ ::= { connUnitLinkEntry 5 }
+
+ connUnitLinkNodeIdY OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(64))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The node WWN of the unit at the other end
+ of the link. If the node WWN is unknown
+ and the node is a connUnit in the responding
+ SNMP agency then the value of this object
+ MUST BE equal to its connUnitID."
+ ::= { connUnitLinkEntry 6 }
+
+ connUnitLinkPortNumberY OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The port number on the unit specified by
+ connUnitLinkNodeIdY if known, otherwise -1.
+ If the value is nonnegative then it will be
+ equal to connUnitPortPhysicalNumber."
+ ::= { connUnitLinkEntry 7 }
+
+ connUnitLinkPortWwnY OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(16))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The port WWN on the unit specified by
+ connUnitLinkNodeIdY if known,
+ otherwise 16 octets of binary 0"
+ ::= { connUnitLinkEntry 8 }
+
+ connUnitLinkAgentAddressY OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(16))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The address of an FCMGMT MIB agent for the
+ node identified by connUnitLinkNodeIdY,
+ if known; otherwise 16 octets of binary 0"
+ ::= { connUnitLinkEntry 9 }
+
+ connUnitLinkAgentAddressTypeY OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "If connUnitLinkAgentAddressY is nonzero,
+ it is a protocol address.
+ ConnUnitLinkAgentAddressTypeY is the
+ the 'address family number' assigned by IANA
+ to identify the address format.
+ (eg, 1 is Ipv4, 2 is Ipv6)."
+ ::= { connUnitLinkEntry 10 }
+
+ connUnitLinkAgentPortY OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The IP port number for the agent. This is
+ provided in case the agent is at a non-standard
+ SNMP port."
+ ::= { connUnitLinkEntry 11 }
+
+ connUnitLinkUnitTypeY OBJECT-TYPE
+ SYNTAX FcUnitType
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Type of the FC connectivity unit as defined in
+ connUnitType."
+ ::= { connUnitLinkEntry 12 }
+
+ connUnitLinkConnIdY OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(3))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This is the Fibre Channel ID of this port.
+ If the connectivity unit is a switch, this
+ is expected to be a Big Endian value of 24
+ bits. If this is loop, then it is the ALPA
+ that is connected. If this is an eport, then
+ it will only contain the domain ID. If not
+ any of those, unknown or cascaded loop,
+ return all bits set to 1."
+ ::= { connUnitLinkEntry 13 }
+
+ connUnitLinkCurrIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The last used link index."
+ ::= { connUnitLinkEntry 14 }
+
+
+------------------------------------------------------------------
+-- The following four tables have been obsoleted. These were used to
+-- keep statistic information based on the type of port type. It was
+-- changed for all ports to use a common statistics table.
+
+-- Hub Port Statistics
+
+-- connUnitPortStatHubTable OBJECT-TYPE
+-- SYNTAX SEQUENCE OF ConnUnitPortStatHubEntry
+-- ACCESS not-accessible
+-- STATUS obsolete
+-- DESCRIPTION
+-- "A list of statistics for the hub port type.
+
+-- This object has been obsoleted."
+-- ::= { statSet 1 }
+
+
+-- Fabric Port Statistics
+
+-- connUnitPortStatFabricTable OBJECT-TYPE
+-- SYNTAX SEQUENCE OF ConnUnitPortStatFabricEntry
+-- ACCESS not-accessible
+-- STATUS obsolete
+-- DESCRIPTION
+-- "A list of statistics for the fabric port types.
+
+-- This object has been obsoleted."
+-- ::= { statSet 2 }
+
+-- SCSI Port Statistics
+
+-- connUnitPortStatSCSITable OBJECT-TYPE
+-- SYNTAX SEQUENCE OF ConnUnitPortStatSCSIEntry
+-- ACCESS not-accessible
+-- STATUS obsolete
+-- DESCRIPTION
+-- "A list of statistics for the SCSI port type.
+
+-- This object has been obsoleted."
+-- ::= { statSet 3 }
+
+-- LAN/WAN Port Statistics
+
+-- connUnitPortStatLANTable OBJECT-TYPE
+-- SYNTAX SEQUENCE OF ConnUnitPortStatLANEntry
+-- ACCESS not-accessible
+-- STATUS obsolete
+-- DESCRIPTION
+-- "A list of statistics for the LAN/WAN port type.
+
+-- This object has been obsoleted."
+-- ::= { statSet 4 }
+
+
+
+-- There is one and only one statistics table for each
+-- individual port. For all objects in statistics table, if the object is not
+-- supported by the conn unit then the high order bit is set to 1 with all other
+-- bits set to zero. The high order bit is reserved to indicate if the object
+-- if supported or not. All objects start at a value of zero at hardware
+-- initialization and continue incrementing till end of 63 bits and then
+-- wrap to zero.
+
+-- Port Statistics
+
+ connUnitPortStatTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ConnUnitPortStatEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of statistics for the fabric port types."
+ ::= { statSet 5 }
+
+ connUnitPortStatEntry OBJECT-TYPE
+ SYNTAX ConnUnitPortStatEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "An entry describing port statistics."
+ INDEX { connUnitPortStatUnitId,
+ connUnitPortStatIndex }
+ ::= { connUnitPortStatTable 1 }
+
+ ConnUnitPortStatEntry ::=
+ SEQUENCE {
+ connUnitPortStatUnitId
+ FcGlobalId,
+ connUnitPortStatIndex
+ INTEGER,
+ connUnitPortStatCountError
+ OCTET STRING,
+ connUnitPortStatCountTxObjects
+ OCTET STRING,
+ connUnitPortStatCountRxObjects
+ OCTET STRING,
+ connUnitPortStatCountTxElements
+ OCTET STRING,
+ connUnitPortStatCountRxElements
+ OCTET STRING,
+ connUnitPortStatCountBBCreditZero
+ OCTET STRING,
+ connUnitPortStatCountInputBuffersFull
+ OCTET STRING,
+ connUnitPortStatCountFBSYFrames
+ OCTET STRING,
+ connUnitPortStatCountPBSYFrames
+ OCTET STRING,
+ connUnitPortStatCountFRJTFrames
+ OCTET STRING,
+ connUnitPortStatCountPRJTFrames
+ OCTET STRING,
+ connUnitPortStatCountClass1RxFrames
+ OCTET STRING,
+ connUnitPortStatCountClass1TxFrames
+ OCTET STRING,
+ connUnitPortStatCountClass1FBSYFrames
+ OCTET STRING,
+ connUnitPortStatCountClass1PBSYFrames
+ OCTET STRING,
+ connUnitPortStatCountClass1FRJTFrames
+ OCTET STRING,
+ connUnitPortStatCountClass1PRJTFrames
+ OCTET STRING,
+ connUnitPortStatCountClass2RxFrames
+ OCTET STRING,
+ connUnitPortStatCountClass2TxFrames
+ OCTET STRING,
+ connUnitPortStatCountClass2FBSYFrames
+ OCTET STRING,
+ connUnitPortStatCountClass2PBSYFrames
+ OCTET STRING,
+ connUnitPortStatCountClass2FRJTFrames
+ OCTET STRING,
+ connUnitPortStatCountClass2PRJTFrames
+ OCTET STRING,
+ connUnitPortStatCountClass3RxFrames
+ OCTET STRING,
+ connUnitPortStatCountClass3TxFrames
+ OCTET STRING,
+ connUnitPortStatCountClass3Discards
+ OCTET STRING,
+ connUnitPortStatCountRxMulticastObjects
+ OCTET STRING,
+ connUnitPortStatCountTxMulticastObjects
+ OCTET STRING,
+ connUnitPortStatCountRxBroadcastObjects
+ OCTET STRING,
+ connUnitPortStatCountTxBroadcastObjects
+ OCTET STRING,
+ connUnitPortStatCountRxLinkResets
+ OCTET STRING,
+ connUnitPortStatCountTxLinkResets
+ OCTET STRING,
+ connUnitPortStatCountNumberLinkResets
+ OCTET STRING,
+ connUnitPortStatCountRxOfflineSequences
+ OCTET STRING,
+ connUnitPortStatCountTxOfflineSequences
+ OCTET STRING,
+ connUnitPortStatCountNumberOfflineSequences
+ OCTET STRING,
+ connUnitPortStatCountLinkFailures
+ OCTET STRING,
+ connUnitPortStatCountInvalidCRC
+ OCTET STRING,
+ connUnitPortStatCountInvalidTxWords
+ OCTET STRING,
+ connUnitPortStatCountPrimitiveSequenceProtocolErrors
+ OCTET STRING,
+ connUnitPortStatCountLossofSignal
+ OCTET STRING,
+ connUnitPortStatCountLossofSynchronization
+ OCTET STRING,
+ connUnitPortStatCountInvalidOrderedSets
+ OCTET STRING,
+ connUnitPortStatCountFramesTooLong
+ OCTET STRING,
+ connUnitPortStatCountFramesTruncated
+ OCTET STRING,
+ connUnitPortStatCountAddressErrors
+ OCTET STRING,
+ connUnitPortStatCountDelimiterErrors
+ OCTET STRING,
+ connUnitPortStatCountEncodingDisparityErrors
+ OCTET STRING
+ }
+
+ connUnitPortStatUnitId OBJECT-TYPE
+ SYNTAX FcGlobalId
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The connUnitId of the connectivity unit
+ that contains this port stat table."
+ ::= { connUnitPortStatEntry 1 }
+
+ connUnitPortStatIndex OBJECT-TYPE
+ SYNTAX INTEGER (0..2147483647)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A unique value among all entrys
+ in this table, between 0 and
+ connUnitNumPort[connUnitPortUnitId]."
+ ::= { connUnitPortStatEntry 2 }
+
+ connUnitPortStatCountError OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (8))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A count of the errors that have occured
+ on this port."
+ ::= { connUnitPortStatEntry 3 }
+
+ connUnitPortStatCountTxObjects OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (8))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of frames/packets/IOs/etc that have been transmitted
+ by this port. Note: A Fibre Channel frame starts with SOF and
+ ends with EOF. FC loop devices should not count frames passed
+ through. This value represents the sum total for all other Tx
+ objects."
+ ::= { connUnitPortStatEntry 4 }
+
+ connUnitPortStatCountRxObjects OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (8))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of frames/packets/IOs/etc that have been received
+ by this port. Note: A Fibre Channel frame starts with SOF and
+ ends with EOF. FC loop devices should not count frames passed
+ through. This value represents the sum total for all other Rx
+ objects."
+ ::= { connUnitPortStatEntry 5 }
+
+ connUnitPortStatCountTxElements OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (8))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of octets or bytes that have been transmitted
+ by this port. One second periodic polling of the port. This
+ value is saved and compared with the next polled value to
+ compute net throughput. Note, for Fibre Channel, ordered
+ sets are not included in the count."
+ ::= { connUnitPortStatEntry 6 }
+
+ connUnitPortStatCountRxElements OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (8))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of octets or bytes that have been received.
+ by this port. One second periodic polling of the port. This
+ value is saved and compared with the next polled value to
+ compute net throughput. Note, for Fibre Channel, ordered
+ sets are not included in the count."
+ ::= { connUnitPortStatEntry 7 }
+
+ connUnitPortStatCountBBCreditZero OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (8))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Count of transitions in/out of BBcredit zero state.
+ The other side is not providing any credit. Note,
+ this is a Fibre Channel stat only."
+ ::= { connUnitPortStatEntry 8 }
+
+ connUnitPortStatCountInputBuffersFull OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (8))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Count of occurrences when all input buffers of a
+ port were full and outbound buffer-to-buffer credit
+ transitioned to zero. There is no credit to
+ provide to other side. Note, this is a Fibre Channel
+ stat only."
+ ::= { connUnitPortStatEntry 9 }
+
+ connUnitPortStatCountFBSYFrames OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (8))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Count of times that FBSY was returned to this port as a
+ result of a frame that could not be delivered to the other
+ end of the link. This occurs if either the Fabric or the
+ destination port is temporarily busy. Port can only occur
+ on SOFc1 frames (the frames that establish a connection).
+ Note, this is a Fibre Channel only stat. This is the sum
+ of all classes. If you cannot keep the by class counters,
+ then keep the sum counters."
+ ::= { connUnitPortStatEntry 10 }
+
+ connUnitPortStatCountPBSYFrames OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (8))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Count of times that PBSY was returned to this port as a
+ result of a frame that could not be delivered to the other
+ end of the link. This occurs if the destination port is
+ temporarily busy. PBSY can only occur on SOFc1 frames
+ (the frames that establish a connection). Note, this is
+ a Fibre Channel only stat.This is the sum
+ of all classes. If you cannot keep the by class counters,
+ then keep the sum counters."
+ ::= { connUnitPortStatEntry 11 }
+
+ connUnitPortStatCountFRJTFrames OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (8))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Count of times that FRJT was returned to this port as a
+ result of a Frame that was rejected by the fabric. Note,
+ This is the total for all classes and is a Fibre Channel
+ only stat."
+ ::= { connUnitPortStatEntry 12 }
+
+ connUnitPortStatCountPRJTFrames OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (8))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Count of times that FRJT was returned to this port as a
+ result of a Frame that was rejected at the destination
+ N_Port. Note, This is the total for all classes and is
+ a Fibre Channel only stat."
+ ::= { connUnitPortStatEntry 13 }
+
+ connUnitPortStatCountClass1RxFrames OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (8))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Count of Class 1 Frames received at this port. Note, this
+ is a Fibre Channel only stat."
+ ::= { connUnitPortStatEntry 14 }
+
+ connUnitPortStatCountClass1TxFrames OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (8))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Count of Class 1 Frames transmitted out this port. Note,
+ this is a Fibre Channel only stat."
+ ::= { connUnitPortStatEntry 15 }
+
+ connUnitPortStatCountClass1FBSYFrames OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (8))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Count of times that FBSY was returned to this port as a
+ result of a Class 1 Frame that could not be delivered to the
+ other end of the link. This occurs if either the Fabric or the
+ destination port is temporarily busy. FBSY can only occur on
+ SOFc1 frames (the frames that establish a connection). Note,
+ this is a Fibre Channel only stat."
+ ::= { connUnitPortStatEntry 16 }
+
+ connUnitPortStatCountClass1PBSYFrames OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (8))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Count of times that PBSY was returned to this port as a result
+ of a Class 1 Frame that could not be delivered to the other end
+ of the link. This occurs if the destination N_Port is temporarily
+ busy. PBSY can only occur on SOFc1 frames (the frames that
+ establish a connection). Note, this is a Fibre Channel only
+ stat."
+ ::= { connUnitPortStatEntry 17 }
+
+ connUnitPortStatCountClass1FRJTFrames OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (8))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Count of times that FRJT was returned to this port as a result
+ of a Class 1 Frame that was rejected by the fabric. Note, this
+ is a Fibre Channel only stat."
+ ::= { connUnitPortStatEntry 18 }
+
+ connUnitPortStatCountClass1PRJTFrames OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (8))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Count of times that FRJT was returned to this port as a result
+ of a Class 1 Frame that was rejected at the destination N_Port.
+ Note, this is a Fibre Channel only stat."
+ ::= { connUnitPortStatEntry 19 }
+
+ connUnitPortStatCountClass2RxFrames OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (8))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Count of Class 2 Frames received at this port. Note, this
+ is a Fibre Channel only stat."
+ ::= { connUnitPortStatEntry 20 }
+
+ connUnitPortStatCountClass2TxFrames OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (8))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Count of Class 2 Frames transmitted out this port. Note,
+ this is a Fibre Channel only stat."
+ ::= { connUnitPortStatEntry 21 }
+
+ connUnitPortStatCountClass2FBSYFrames OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (8))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Count of times that FBSY was returned to this port as a
+ result of a Class 2 Frame that could not be delivered to the
+ other end of the link. This occurs if either the Fabric or the
+ destination port is temporarily busy. FBSY can only occur on
+ SOFc1 frames (the frames that establish a connection). Note,
+ this is a Fibre Channel only stat."
+ ::= { connUnitPortStatEntry 22 }
+
+ connUnitPortStatCountClass2PBSYFrames OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (8))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Count of times that PBSY was returned to this port as a result
+ of a Class 2 Frame that could not be delivered to the other end
+ of the link. This occurs if the destination N_Port is temporarily
+ busy. PBSY can only occur on SOFc1 frames (the frames that
+ establish a connection). Note, this is a Fibre Channel only
+ stat."
+ ::= { connUnitPortStatEntry 23 }
+
+ connUnitPortStatCountClass2FRJTFrames OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (8))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Count of times that FRJT was returned to this port as a result
+ of a Class 2 Frame that was rejected by the fabric. Note, this
+ is a Fibre Channel only stat."
+ ::= { connUnitPortStatEntry 24 }
+
+ connUnitPortStatCountClass2PRJTFrames OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (8))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Count of times that FRJT was returned to this port as a result
+ of a Class 2 Frame that was rejected at the destination N_Port.
+ Note, this is a Fibre Channel only stat."
+ ::= { connUnitPortStatEntry 25 }
+
+ connUnitPortStatCountClass3RxFrames OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (8))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Count of Class 3 Frames received at this port. Note, this
+ is a Fibre Channel only stat."
+ ::= { connUnitPortStatEntry 26 }
+
+ connUnitPortStatCountClass3TxFrames OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (8))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Count of Class 3 Frames transmitted out this port. Note,
+ this is a Fibre Channel only stat."
+ ::= { connUnitPortStatEntry 27 }
+
+ connUnitPortStatCountClass3Discards OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (8))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Count of Class 3 Frames that were discarded upon reception
+ at this port. There is no FBSY or FRJT generated for Class 3
+ Frames. They are simply discarded if they cannot be delivered.
+ Note, this is a Fibre Channel only stat."
+ ::= { connUnitPortStatEntry 28 }
+
+ connUnitPortStatCountRxMulticastObjects OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (8))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Count of Multicast Frames or Packets received at this port."
+ ::= { connUnitPortStatEntry 29 }
+
+ connUnitPortStatCountTxMulticastObjects OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (8))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Count of Multicast Frames or Packets transmitted out this port."
+ ::= { connUnitPortStatEntry 30 }
+
+ connUnitPortStatCountRxBroadcastObjects OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (8))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Count of Broadcast Frames or Packets received at this port."
+ ::= { connUnitPortStatEntry 31 }
+
+ connUnitPortStatCountTxBroadcastObjects OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (8))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Count of Broadcast Frames or Packets transmitted out this port.
+ On a Fibre Channel loop, count only OPNr frames generated."
+ ::= { connUnitPortStatEntry 32 }
+
+ connUnitPortStatCountRxLinkResets OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (8))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Count of Link resets. This is the number of LRs received. Note, this
+ is a Fibre Channel only stat."
+ ::= { connUnitPortStatEntry 33 }
+
+ connUnitPortStatCountTxLinkResets OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (8))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Count of Link resets. This is the number LRs transmitted. Note, this
+ is a Fibre Channel only stat."
+ ::= { connUnitPortStatEntry 34 }
+
+ connUnitPortStatCountNumberLinkResets OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (8))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Count of Link resets and LIPs detected at this port.
+ The number times the reset link protocol is initiated.
+ These are the count of the logical resets, a count of the
+ number of primatives. Note, this is a Fibre Channel only
+ stat."
+ ::= { connUnitPortStatEntry 35 }
+
+ connUnitPortStatCountRxOfflineSequences OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (8))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Count of Offline Primitive OLS received at this port.
+ Note, this is a Fibre Channel only stat."
+ ::= { connUnitPortStatEntry 36 }
+
+ connUnitPortStatCountTxOfflineSequences OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (8))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Count of Offline Primitive OLS transmitted by this port.
+ Note, this is a Fibre Channel only stat."
+ ::= { connUnitPortStatEntry 37 }
+
+ connUnitPortStatCountNumberOfflineSequences OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (8))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Count of Offline Primitive sequence received at this port.
+ Note, this is a Fibre Channel only stat."
+ ::= { connUnitPortStatEntry 38 }
+
+ connUnitPortStatCountLinkFailures OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (8))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Count of link failures. This count is part of the Link Error
+ Status Block (LESB). (FC-PH 29.8). Note, this is a Fibre
+ Channel only stat."
+ ::= { connUnitPortStatEntry 39 }
+
+ connUnitPortStatCountInvalidCRC OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (8))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Count of frames received with invalid CRC. This count is
+ part of the Link Error Status Block (LESB). (FC-PH 29.8). Loop
+ ports should not count CRC errors passing through when
+ monitoring. Note, this is a Fibre Channel only stat."
+ ::= { connUnitPortStatEntry 40 }
+
+ connUnitPortStatCountInvalidTxWords OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (8))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Count of invalid transmission words received at this
+ port. This count is part of the Link Error Status Block (LESB).
+ (FC-PH 29.8). Note, this is a Fibre Channel only stat."
+ ::= { connUnitPortStatEntry 41 }
+
+ connUnitPortStatCountPrimitiveSequenceProtocolErrors OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (8))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Count of primitive sequence protocol errors detected at
+ this port. This count is part of the Link Error Status
+ Block (LESB). (FC-PH 29.8). Note, this is a Fibre Channel
+ only stat."
+ ::= { connUnitPortStatEntry 42 }
+
+ connUnitPortStatCountLossofSignal OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (8))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Count of instances of signal loss detected at port.
+ This count is part of the Link Error Status Block (LESB).
+ (FC-PH 29.8). Note, this is a Fibre Channel only stat."
+ ::= { connUnitPortStatEntry 43 }
+
+ connUnitPortStatCountLossofSynchronization OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (8))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Count of instances of synchronization loss detected at port.
+ This count is part of the Link Error Status Block (LESB).
+ (FC-PH 29.8). Note, this is a Fibre Channel only stat."
+ ::= { connUnitPortStatEntry 44 }
+
+ connUnitPortStatCountInvalidOrderedSets OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (8))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Count of invalid ordered sets received at port. This count
+ is part of the Link Error Status Block (LESB). (FC-PH 29.8).
+ Note, this is a Fibre Channel only stat."
+ ::= { connUnitPortStatEntry 45 }
+
+ connUnitPortStatCountFramesTooLong OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (8))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Count of frames received at this port where the
+ frame length was greater than what was agreed to in
+ FLOGI/PLOGI. This could be caused by losing the end of
+ frame delimiter. Note, this is a Fibre Channel only stat."
+ ::= { connUnitPortStatEntry 46 }
+
+ connUnitPortStatCountFramesTruncated OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (8))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Count of frames received at this port where the
+ frame length was less than the minimum indicated by the
+ frame header - normally 24 bytes, but it could be more if the
+ DFCTL field indicates an optional header should have been
+ present. Note, this is a Fibre Channel only stat."
+ ::= { connUnitPortStatEntry 47 }
+
+ connUnitPortStatCountAddressErrors OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (8))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Count of frames received with unknown addressing.
+ e.x. unknown SID or DID. the SID or DID is not known to the
+ routing algorithm. Note. this is a Fibre Channel only stat."
+ ::= { connUnitPortStatEntry 48 }
+
+ connUnitPortStatCountDelimiterErrors OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (8))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Count of invalid frame delimiters received at this
+ port. An example is a frame with a class 2 start and and a
+ class 3 at the end. Note, this is a Fibre Channel only stat."
+ ::= { connUnitPortStatEntry 49 }
+
+ connUnitPortStatCountEncodingDisparityErrors OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (8))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Count of disparity errors received at this port. Note,
+ this is a Fibre Channel only stat."
+ ::= { connUnitPortStatEntry 50 }
+
+
+--------------------------------------------------------------------
+-- the Fibre Channel Simple Name Server table
+--
+-- The Fibre Channel Simple Name Server table contains an entry for each device
+-- presently known to this connUnit. There will not be any version on this since
+-- FC-GS3 does not define a version today.
+--
+-- This table is accessed either directly if the management
+-- software has an index value or via GetNexts. The value of
+-- the indexes are not required to be contiguous. Each entry
+-- created in this table will be assigned an index. This
+-- relationship is kept persistent until the entry is removed
+-- from the table or the system is reset. The total number of
+-- entries are defined by the size of the table
+
+connUnitSnsMaxEntry OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The maximum number of entries in the table."
+ ::= { connUnitServiceScalars 1 }
+
+connUnitSnsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ConnUnitSnsEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "This table contains an entry for each object registered with
+ this port in the switch."
+ ::= { connUnitServiceTables 1 }
+
+connUnitSnsEntry OBJECT-TYPE
+ SYNTAX ConnUnitSnsEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The Simple Name Server table for the port represented by
+ connUnitSnsPortIndex ."
+ INDEX { connUnitSnsId, connUnitSnsPortIndex, connUnitSnsPortIdentifier }
+ ::= { connUnitSnsTable 1 }
+
+ConnUnitSnsEntry ::=
+ SEQUENCE {
+ connUnitSnsId
+ OCTET STRING,
+ connUnitSnsPortIndex
+ INTEGER,
+ connUnitSnsPortIdentifier
+ FcAddressId,
+ connUnitSnsPortName
+ FcNameId,
+ connUnitSnsNodeName
+ FcNameId,
+ connUnitSnsClassOfSvc
+ OCTET STRING,
+ connUnitSnsNodeIPAddress
+ OCTET STRING,
+ connUnitSnsProcAssoc
+ OCTET STRING,
+ connUnitSnsFC4Type
+ OCTET STRING,
+ connUnitSnsPortType
+ OCTET STRING,
+ connUnitSnsPortIPAddress
+ OCTET STRING,
+ connUnitSnsFabricPortName
+ FcNameId,
+ connUnitSnsHardAddress
+ FcAddressId,
+ connUnitSnsSymbolicPortName
+ DisplayString,
+ connUnitSnsSymbolicNodeName
+ DisplayString
+ }
+
+connUnitSnsId OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (16))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The connUnitId of the connectivity unit
+ that contains this Name Server table."
+ ::= { connUnitSnsEntry 1 }
+
+connUnitSnsPortIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The physical port number of this SNS table entry. Each physical port
+ has an SNS table with 1-n entries indexed by connUnitSnsPortIdentifier (port
+ address)"
+ ::= { connUnitSnsEntry 2 }
+
+connUnitSnsPortIdentifier OBJECT-TYPE
+ SYNTAX FcAddressId
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The Port Identifier for this entry in the SNS table."
+ ::= { connUnitSnsEntry 3 }
+
+connUnitSnsPortName OBJECT-TYPE
+ SYNTAX FcNameId
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The Port Name for this entry in the SNS table."
+ ::= { connUnitSnsEntry 4 }
+
+connUnitSnsNodeName OBJECT-TYPE
+ SYNTAX FcNameId
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The Node Name for this entry in the SNS table."
+ ::= { connUnitSnsEntry 5 }
+
+connUnitSnsClassOfSvc OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(1))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The Classes of Service offered by this entry in the SNS table."
+ ::= { connUnitSnsEntry 6 }
+
+connUnitSnsNodeIPAddress OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(16))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The IPv6 formatted address of the Node for this entry in the SNS table."
+
+ ::= { connUnitSnsEntry 7 }
+
+connUnitSnsProcAssoc OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(1))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The Process Associator for this entry in the SNS table."
+ ::= { connUnitSnsEntry 8 }
+
+connUnitSnsFC4Type OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(1))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The FC-4 Types supported by this entry in the SNS table."
+ ::= { connUnitSnsEntry 9 }
+
+connUnitSnsPortType OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(1))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The Port Type of this entry in the SNS table."
+ ::= { connUnitSnsEntry 10 }
+
+connUnitSnsPortIPAddress OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(16))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The IPv6 formatted address of this entry in the SNS table."
+ ::= { connUnitSnsEntry 11 }
+
+connUnitSnsFabricPortName OBJECT-TYPE
+ SYNTAX FcNameId
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The Fabric Port name of this entry in the SNS table."
+ ::= { connUnitSnsEntry 12 }
+
+connUnitSnsHardAddress OBJECT-TYPE
+ SYNTAX FcAddressId
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The Hard Address of this entry in the SNS table."
+ ::= { connUnitSnsEntry 13 }
+
+connUnitSnsSymbolicPortName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..79))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The Symbolic Port Name of this entry in the SNS table."
+ ::= { connUnitSnsEntry 14 }
+
+connUnitSnsSymbolicNodeName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..79))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The Symbolic Node Name of this entry in the SNS table."
+ ::= { connUnitSnsEntry 15 }
+
+
+-----------------------------------------------------------------------
+-- SNMP trap registration group
+
+ trapMaxClients OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The maximum number of SNMP trap recipients
+ supported by the connectivity unit."
+ ::= { trapReg 1 }
+
+ trapClientCount OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The current number of rows in the trap table."
+ ::= { trapReg 2 }
+
+ trapRegTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TrapRegEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A table containing a row for each IP address/port
+ number that traps will be sent to."
+ ::= { trapReg 3 }
+
+ trapRegEntry OBJECT-TYPE
+ SYNTAX TrapRegEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Ip/Port pair for a specific client."
+ INDEX { trapRegIpAddress,
+ trapRegPort }
+ ::= { trapRegTable 1 }
+
+ TrapRegEntry ::=
+ SEQUENCE {
+ trapRegIpAddress
+ IpAddress,
+ trapRegPort
+ INTEGER,
+ trapRegFilter
+ FcEventSeverity,
+ trapRegRowState
+ INTEGER
+ }
+
+ trapRegIpAddress OBJECT-TYPE
+ SYNTAX IpAddress
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The Ip address of a client registered for
+ traps."
+ ::= { trapRegEntry 1 }
+
+ trapRegPort OBJECT-TYPE
+ SYNTAX INTEGER (1..2147483647)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The UDP port to send traps to for this host.
+ Normally this would be the standard trap port
+ (162). This object is an index and must be
+ specified to create a row in this table."
+ ::= { trapRegEntry 2 }
+
+ trapRegFilter OBJECT-TYPE
+ SYNTAX FcEventSeverity
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This value defines the trap severity
+ filter for this trap host. The connUnit will send
+ traps to this host that have a severity level
+ less than or equal to this value.
+ The default value of this object is 'warning'."
+ ::= { trapRegEntry 3}
+
+ trapRegRowState OBJECT-TYPE
+ SYNTAX INTEGER {
+ rowDestroy(1), -- Remove row from table.
+ rowInactive(2), -- Row exists, but TRAPs disabled
+ rowActive(3) -- Row exists and is enabled for
+ -- sending traps
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies the state of the row.
+ rowDestroy
+ READ: Can never happen.
+ WRITE: Remove this row from the table.
+ rowInactive
+ READ: Indicates that this row does exist, but
+ that traps are not enabled to be sent to the
+ target.
+ WRITE: If the row does not exist, and the agent
+ allows writes to the trap table, then a new
+ row is created. The values of the optional
+ columns will be set to default values. Traps are
+ not enabled to be sent to the target. If the row
+ already existed, then traps are disabled from being
+ sent to the target.
+ rowActive
+ READ: Indicates that this row exists, and that traps
+ are enabled to be sent to the target.
+ WRITE: If the row does not exist, and the agent
+ allows writes to the trap table, then a new row is
+ created. The values of the optional columns will be
+ set to default values. Traps are enabled to be sent
+ to the target. If the row already exists, then traps
+ are enabled to be sent to the target.
+
+ A value of rowActive or rowInactive must be specified to
+ create a row in the table."
+ ::= { trapRegEntry 4}
+
+
+-- Related traps
+
+ connUnitStatusChange TRAP-TYPE
+ ENTERPRISE fcmgmt
+ VARIABLES { connUnitStatus, connUnitState }
+ DESCRIPTION
+ "The overall status of the connectivity unit has
+ changed.
+ Recommended severity level (for filtering): alert"
+ ::= 1
+
+ -- connUnitAddedTrap , 2, no longer used
+
+ connUnitDeletedTrap TRAP-TYPE
+ ENTERPRISE fcmgmt
+ VARIABLES { connUnitId }
+ DESCRIPTION
+ "A connUnit has been deleted from this agent.
+ Recommended severity level (for filtering): warning"
+ ::= 3
+
+ connUnitEventTrap TRAP-TYPE
+ ENTERPRISE fcmgmt
+ VARIABLES { connUnitEventId,
+ connUnitEventType,
+ connUnitEventObject,
+ connUnitEventDescr }
+ DESCRIPTION
+ "An event has been generated by the
+ connectivity unit.
+ Recommended severity level (for filtering): info"
+ ::= 4
+
+ connUnitSensorStatusChange TRAP-TYPE
+ ENTERPRISE fcmgmt
+ VARIABLES { connUnitSensorStatus }
+ DESCRIPTION
+ "The overall status of the connectivity unit has
+ changed.
+ Recommended severity level (for filtering): alert"
+ ::= 5
+
+ connUnitPortStatusChange TRAP-TYPE
+ ENTERPRISE fcmgmt
+ VARIABLES { connUnitPortStatus, connUnitPortState }
+ DESCRIPTION
+ "The overall status of the connectivity unit has
+ changed.
+ Recommended severity level (for filtering): alert"
+ ::= 6
+
+END
+
+
+