@@ -0,0 +1,1182 @@
+--
+-- Accedian Enterprise Specific MIB
+--
+-- Copyright (c) 2005-2010, Accedian Networks, Inc.
+-- All rights reserved.
+--
+-- The contents of this document is subject to change without notice.
+--
+
+
+ACD-SFP-MIB DEFINITIONS ::= BEGIN
+
+IMPORTS
+ MODULE-IDENTITY, OBJECT-TYPE,
+ Integer32, Unsigned32
+ FROM SNMPv2-SMI
+ DisplayString, TruthValue
+ FROM SNMPv2-TC
+ MODULE-COMPLIANCE, OBJECT-GROUP
+ FROM SNMPv2-CONF
+ acdMibs
+ FROM ACCEDIAN-SMI;
+
+acdSfp MODULE-IDENTITY
+
+ LAST-UPDATED "201011100100Z"
+ ORGANIZATION "Accedian Networks, Inc."
+ CONTACT-INFO
+ "Accedian Technical Assistance Center
+ Accedian Networks, Inc.
+ 4878 Levy, suite 202
+ Saint-Laurent, Quebec Canada H4R 2P1
+ E-mail: support@accedian.com"
+ DESCRIPTION
+ "The SFPs database for this Accedian Networks device."
+
+ REVISION "201011100100Z" -- 10 November 2010
+ DESCRIPTION
+ "Add compliance section."
+
+ REVISION "200804220100Z" -- 22 April 2008
+ DESCRIPTION
+ "Add acdSfpInfoIdType, acdSfpInfoExtIdType and acdSfpInfoTransCode support."
+
+ REVISION "200608060100Z" -- 6 Aug 2006
+ DESCRIPTION
+ "Initial version of MIB module ACD-SFP-MIB."
+
+ ::= { acdMibs 4 }
+
+acdSfpNotifications OBJECT IDENTIFIER ::= { acdSfp 5 }
+acdSfpMIBObjects OBJECT IDENTIFIER ::= { acdSfp 6 }
+acdSfpConformance OBJECT IDENTIFIER ::= { acdSfp 7 }
+
+-----------------------------------------------------------------------
+ -- The information SFP table
+ -- This table contains all SFP Info.
+---------------------------------------------------------------------------
+
+acdSfpInfoTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AcdSfpInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of all SFP info"
+ ::= { acdSfp 1 }
+
+acdSfpInfoEntry OBJECT-TYPE
+ SYNTAX AcdSfpInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This is a part of the content of the SFP's 0xA0 EEPROM"
+ INDEX { acdSfpInfoID }
+ ::= { acdSfpInfoTable 1 }
+
+
+AcdSfpInfoEntry ::= SEQUENCE {
+ acdSfpInfoID Unsigned32,
+ acdSfpInfoConnIdx Unsigned32,
+ acdSfpInfoConnType INTEGER,
+ acdSfpInfoVendor DisplayString,
+ acdSfpInfoVendorOui DisplayString,
+ acdSfpInfoVendorPn DisplayString,
+ acdSfpInfoVendorRev DisplayString,
+ acdSfpInfoWavelength Unsigned32,
+ acdSfpInfoSerialNum DisplayString,
+ acdSfpInfoYear Unsigned32,
+ acdSfpInfoMonth Unsigned32,
+ acdSfpInfoDay Unsigned32,
+ acdSfpInfoLot Unsigned32,
+ acdSfpInfoRev8472 INTEGER,
+ acdSfpInfoPresent TruthValue,
+ acdSfpInfoDiag TruthValue,
+ acdSfpInfoInternal TruthValue,
+ acdSfpInfoAlm TruthValue,
+ acdSfpInfoIdType Unsigned32,
+ acdSfpInfoExtIdType Unsigned32,
+ acdSfpInfoTransCode DisplayString
+}
+
+acdSfpInfoID OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Unique value for each SFP. Its value ranges from 1 to
+ MAXINT (4 bytes). "
+ ::= { acdSfpInfoEntry 1 }
+
+acdSfpInfoConnIdx OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object identifies the connector index on the box. The index
+ is assigned form left to rigth starting with 1."
+ ::= { acdSfpInfoEntry 2 }
+
+acdSfpInfoConnType OBJECT-TYPE
+ SYNTAX INTEGER {
+ sfpSC(1),
+ sfpFC1COPPER(2),
+ sfpFC2COPPER(3),
+ sfpBNC(4),
+ sfpFCCOAX(5),
+ sfpFIBERJACK(6),
+ sfpLC(7),
+ sfpMTRJ(8),
+ sfpMU(9),
+ sfpSG(10),
+ sfpPIGTAIL(11),
+ sfpHSSDCII(32),
+ sfpCOPPERPIGTAIL(33)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The connector value indicates the external optical or electrical
+ cable connector provided as the media interface."
+ ::= { acdSfpInfoEntry 3 }
+
+acdSfpInfoVendor OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..16))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The vendor name is a 16 character field that contains ASCII
+ characters, left-aligned and padded on the right with ASCII
+ spaces (20h). The vendor name shall be the full name of the
+ corporation, a commonly accepted abbreviation of the name of
+ the corporation, the SCSI company code for the corporation,
+ or the stock exchange code for the corporation. At least one
+ of the vendor name or the vendor OUI fields shall contain
+ valid serial data."
+ ::= { acdSfpInfoEntry 4 }
+
+acdSfpInfoVendorOui OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (3))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The vendor organizationally unique identifier field (vendor OUI)
+ is a 3-byte field that contains the IEEE Company Identifier for
+ the vendor. A value of all zero in the 3-byte field indicates
+ that the Vendor OUI is unspecified."
+ ::= { acdSfpInfoEntry 5 }
+
+acdSfpInfoVendorPn OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..16))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The vendor part number (vendor PN) is a 16-byte field that
+ contains ASCII characters, leftaligned and padded on the
+ right with ASCII spaces (20h), defining the vendor's part
+ number or product name. A value of all zero in the 16-byte
+ field indicates that the vendor PN is unspecified."
+ ::= { acdSfpInfoEntry 6 }
+
+acdSfpInfoVendorRev OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..16))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The vendor revision number (vendor rev) is a 4-byte field that
+ contains ASCII characters, leftaligned and padded on the right
+ with ASCII spaces (20h), defining the vendor's product revision
+ number. A value of all zero in the 4-byte field indicates that
+ the vendor PN is unspecified."
+ ::= { acdSfpInfoEntry 7 }
+
+acdSfpInfoWavelength OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Nominal transmitter output wavelength at room temperature. 16 bit
+ value with byte 60 as high order byte and byte 61 as low order
+ byte. The laser wavelength is equal to the 16 bit integer
+ value in nm. This field allows the user to read the laser
+ wavelength directly, so it is not necessary to infer it from the
+ transceiver Code for Electronic Compatibility."
+ ::= { acdSfpInfoEntry 8 }
+
+acdSfpInfoSerialNum OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..16))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The vendor serial number (vendor SN) is a 16 character field that
+ contains ASCII characters, left-aligned and padded on the right
+ with ASCII spaces (20h), defining the vendor's serial number for
+ the transceiver. A value of all zero in the 16-byte field indicates
+ that the vendor PN is unspecified."
+ ::= { acdSfpInfoEntry 9 }
+
+acdSfpInfoYear OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This is the year of manufacturing."
+ ::= { acdSfpInfoEntry 10 }
+
+acdSfpInfoMonth OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This is the month of manufacturing."
+ ::= { acdSfpInfoEntry 11 }
+
+acdSfpInfoDay OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This is the day of manufacturing."
+ ::= { acdSfpInfoEntry 12 }
+
+acdSfpInfoLot OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This is the Lot number of manufacturing."
+ ::= { acdSfpInfoEntry 13 }
+
+
+acdSfpInfoRev8472 OBJECT-TYPE
+ SYNTAX INTEGER {
+ undefined(0),
+ rev93(1),
+ rev94(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This is to indicate to which revision this SFP is compatible."
+ ::= { acdSfpInfoEntry 14 }
+
+acdSfpInfoPresent OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This is to indicate if the SFP is present or not."
+ ::= { acdSfpInfoEntry 15 }
+
+acdSfpInfoDiag OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This is to indicate if the SFP supports Digital Diagnostics."
+ ::= { acdSfpInfoEntry 16 }
+
+acdSfpInfoInternal OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This is to indicate if the SFP supports internal calibration. If
+ externally calibrated, the measurements are raw A/D values and must
+ be converted to real world units using calibration constants
+ stored in EEPROM locations 56 to 95 at 2 wire serial bus address
+ A2h. Calibration is valid over vendor specified operating
+ temperature and voltage. Alarm and warning threshold values
+ should be interpreted in the same manner as real time 16 bit data."
+ ::= { acdSfpInfoEntry 17 }
+
+acdSfpInfoAlm OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This is to indicate if the SFP supports Alarm and warning
+ thresholds for the Digital Diagnostics."
+ ::= { acdSfpInfoEntry 18 }
+
+acdSfpInfoIdType OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The identifier value specifies the physical device described by
+ the two-wire interface information. This value shall be included
+ in the two-wire interface data (see SFF-8472 for details)."
+ ::= { acdSfpInfoEntry 19 }
+
+acdSfpInfoExtIdType OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The extended identifier value provides additional information
+ about the transceiver. The field should be set to 04h for all SFP
+ modules indicating two-wire interface ID module definition (see
+ SFF-8472 for details)."
+ ::= { acdSfpInfoEntry 20 }
+
+acdSfpInfoTransCode OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (8))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The following bit significant indicators define the electronic
+ or optical interfaces that are supported by the transceiver. At
+ least one bit shall be set in this field (see SFF-8472 for details)."
+ ::= { acdSfpInfoEntry 21 }
+
+-----------------------------------------------------------------------
+ -- The Digital Diagnostics SFP table
+ -- This table contains all SFP Digital Diagnostics.
+---------------------------------------------------------------------------
+
+acdSfpDiagTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AcdSfpDiagEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of all SFP Digital Diagnostics"
+ ::= { acdSfp 2 }
+
+acdSfpDiagEntry OBJECT-TYPE
+ SYNTAX AcdSfpDiagEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This is a part the content of the SFP's 0xA0 EEPROM"
+ INDEX { acdSfpDiagID }
+ ::= { acdSfpDiagTable 1 }
+
+
+AcdSfpDiagEntry ::= SEQUENCE {
+ acdSfpDiagID Unsigned32,
+ acdSfpDiagConnIdx Unsigned32,
+ acdSfpDiagTemp Integer32,
+ acdSfpDiagVcc Unsigned32,
+ acdSfpDiagLbc Unsigned32,
+ acdSfpDiagTxPwr Unsigned32,
+ acdSfpDiagRxPwr Unsigned32,
+ acdSfpDiagTxPwrdBm DisplayString,
+ acdSfpDiagRxPwrdBm DisplayString
+}
+
+acdSfpDiagID OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Unique value for each SFP. Its value ranges from 1 to
+ MAXINT (4 bytes). "
+ ::= { acdSfpDiagEntry 1 }
+
+acdSfpDiagConnIdx OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object identifies the connector index on the box. The index
+ is assigned form left to rigth starting with 1."
+ ::= { acdSfpDiagEntry 2 }
+
+acdSfpDiagTemp OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Internally measured transceiver temperature. Represented as a
+ 16 bit signed twos complement value in degrees Celsius, yielding
+ a total range of -128C to +128C."
+ ::= { acdSfpDiagEntry 3 }
+
+acdSfpDiagVcc OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Internally measured transceiver supply voltage. Represented as
+ a 16 bit unsigned integer with the voltage defined as the full
+ 16 bit value (0 to 65535) with LSB equal to 100 micro-Volt,
+ yielding a total range of 0 to +6.55 Volts."
+ ::= { acdSfpDiagEntry 4 }
+
+acdSfpDiagLbc OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Measured TX bias current in micro-Amps yielding a total range of
+ 0 to 131 mA."
+ ::= { acdSfpDiagEntry 5 }
+
+acdSfpDiagTxPwr OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Measured TX output power in mW. Represented as a 16 bit unsigned
+ integer with the power defined as the full 16 bit value (0 to 65535)
+ with LSB equal to 0.1 micro-Watt, yielding a total range of 0
+ to 6.5535 mW (~ -40 to +8.2 dBm)."
+ ::= { acdSfpDiagEntry 6 }
+
+acdSfpDiagRxPwr OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Measured Rx input power in mW. Represented as a 16 bit unsigned
+ integer with the power defined as the full 16 bit value (0 to 65535)
+ with LSB equal to 0.1 micro-Watt, yielding a total range of 0
+ to 6.5535 mW (~ -40 to +8.2 dBm)."
+ ::= { acdSfpDiagEntry 7 }
+
+acdSfpDiagTxPwrdBm OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Measured TX output power in dBm (~ -40 to +8.2 dBm)."
+ ::= { acdSfpDiagEntry 8 }
+
+acdSfpDiagRxPwrdBm OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Measured Rx input power in dBm (~ -40 to +8.2 dBm)."
+ ::= { acdSfpDiagEntry 9 }
+
+-----------------------------------------------------------------------
+ -- The Alarm and Warning Thresholds SFP table
+ -- This table contains all SFP Alarm and Warning Thresholds.
+---------------------------------------------------------------------------
+
+acdSfpThreshTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AcdSfpThreshEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of all SFP Alarm and Warning Thresholds"
+ ::= { acdSfp 3 }
+
+acdSfpThreshEntry OBJECT-TYPE
+ SYNTAX AcdSfpThreshEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ " This is a part the content of the SFP's 0xA0 EEPROM"
+ INDEX { acdSfpThreshID }
+ ::= { acdSfpThreshTable 1 }
+
+
+AcdSfpThreshEntry ::= SEQUENCE {
+ acdSfpThreshID Unsigned32,
+ acdSfpThreshConnIdx Unsigned32,
+ acdSfpThreshTempHighAlm Integer32,
+ acdSfpThreshTempLowAlm Integer32,
+ acdSfpThreshTempHighWarn Integer32,
+ acdSfpThreshTempLowWarn Integer32,
+ acdSfpThreshVccHighAlm Unsigned32,
+ acdSfpThreshVccLowAlm Unsigned32,
+ acdSfpThreshVccHighWarn Unsigned32,
+ acdSfpThreshVccLowWarn Unsigned32,
+ acdSfpThreshLbcHighAlm Unsigned32,
+ acdSfpThreshLbcLowAlm Unsigned32,
+ acdSfpThreshLbcHighWarn Unsigned32,
+ acdSfpThreshLbcLowWarn Unsigned32,
+ acdSfpThreshTxPwrHighAlm Unsigned32,
+ acdSfpThreshTxPwrLowAlm Unsigned32,
+ acdSfpThreshTxPwrHighWarn Unsigned32,
+ acdSfpThreshTxPwrLowWarn Unsigned32,
+ acdSfpThreshRxPwrHighAlm Unsigned32,
+ acdSfpThreshRxPwrLowAlm Unsigned32,
+ acdSfpThreshRxPwrHighWarn Unsigned32,
+ acdSfpThreshRxPwrLowWarn Unsigned32,
+ acdSfpThreshTxPwrHighAlmdBm DisplayString,
+ acdSfpThreshTxPwrLowAlmdBm DisplayString,
+ acdSfpThreshTxPwrHighWarndBm DisplayString,
+ acdSfpThreshTxPwrLowWarndBm DisplayString,
+ acdSfpThreshRxPwrHighAlmdBm DisplayString,
+ acdSfpThreshRxPwrLowAlmdBm DisplayString,
+ acdSfpThreshRxPwrHighWarndBm DisplayString,
+ acdSfpThreshRxPwrLowWarndBm DisplayString
+
+}
+
+acdSfpThreshID OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Unique value for each SFP. Its value ranges from 1 to
+ MAXINT (4 bytes). "
+ ::= { acdSfpThreshEntry 1 }
+
+acdSfpThreshConnIdx OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object identifies the connector index on the box. The index
+ is assigned form left to rigth starting with 1."
+ ::= { acdSfpThreshEntry 2 }
+
+acdSfpThreshTempHighAlm OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "High Alarm transceiver temperature. Represented as a 16 bit
+ signed twos complement value in degrees Celsius, yielding
+ a total range of -128C to +128C."
+ ::= { acdSfpThreshEntry 3 }
+
+acdSfpThreshTempLowAlm OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Low Alarm transceiver temperature. Represented as a 16 bit
+ signed twos complement value in degrees Celsius, yielding
+ a total range of -128C to +128C."
+ ::= { acdSfpThreshEntry 4 }
+
+acdSfpThreshTempHighWarn OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "High Warning transceiver temperature. Represented as a 16 bit
+ signed twos complement value in degrees Celsius, yielding
+ a total range of -128C to +128C."
+ ::= { acdSfpThreshEntry 5 }
+
+acdSfpThreshTempLowWarn OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Low Warning transceiver temperature. Represented as a 16 bit
+ signed twos complement value in degrees Celsius, yielding
+ a total range of -128C to +128C."
+ ::= { acdSfpThreshEntry 6 }
+
+acdSfpThreshVccHighAlm OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "High Alarm transceiver supply voltage. Represented as
+ a 16 bit unsigned integer with the voltage defined as the full
+ 16 bit value (0 to 65535) with LSB equal to 100 micro-Volt,
+ yielding a total range of 0 to +6.55 Volts."
+ ::= { acdSfpThreshEntry 7 }
+
+acdSfpThreshVccLowAlm OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Low Alarm transceiver supply voltage. Represented as
+ a 16 bit unsigned integer with the voltage defined as the full
+ 16 bit value (0 to 65535) with LSB equal to 100 micro-Volt,
+ yielding a total range of 0 to +6.55 Volts."
+ ::= { acdSfpThreshEntry 8 }
+
+acdSfpThreshVccHighWarn OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "High Warning transceiver supply voltage. Represented as
+ a 16 bit unsigned integer with the voltage defined as the full
+ 16 bit value (0 to 65535) with LSB equal to 100 micro-Volt,
+ yielding a total range of 0 to +6.55 Volts."
+ ::= { acdSfpThreshEntry 9 }
+
+acdSfpThreshVccLowWarn OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Low Warning transceiver supply voltage. Represented as
+ a 16 bit unsigned integer with the voltage defined as the full
+ 16 bit value (0 to 65535) with LSB equal to 100 micro-Volt,
+ yielding a total range of 0 to +6.55 Volts."
+ ::= { acdSfpThreshEntry 10 }
+
+acdSfpThreshLbcHighAlm OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "High Alarm TX bias current in micro-Amps yielding a total range of
+ 0 to 131 mA."
+ ::= { acdSfpThreshEntry 11 }
+
+acdSfpThreshLbcLowAlm OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Low Alarm TX bias current in micro-Amps yielding a total range of
+ 0 to 131 mA."
+ ::= { acdSfpThreshEntry 12 }
+
+acdSfpThreshLbcHighWarn OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "High Warning TX bias current in micro-Amps yielding a total range of
+ 0 to 131 mA."
+ ::= { acdSfpThreshEntry 13 }
+
+acdSfpThreshLbcLowWarn OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Low Warning TX bias current in micro-Amps yielding a total range of
+ 0 to 131 mA."
+ ::= { acdSfpThreshEntry 14 }
+
+acdSfpThreshTxPwrHighAlm OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "High Alarm TX output power in mW. Represented as a 16 bit unsigned
+ integer with the power defined as the full 16 bit value (0 to 65535)
+ with LSB equal to 0.1 micro-Watt, yielding a total range of 0
+ to 6.5535 mW (~ -40 to +8.2 dBm)."
+ ::= { acdSfpThreshEntry 15 }
+
+acdSfpThreshTxPwrLowAlm OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Low Alarm TX output power in mW. Represented as a 16 bit unsigned
+ integer with the power defined as the full 16 bit value (0 to 65535)
+ with LSB equal to 0.1 micro-Watt, yielding a total range of 0
+ to 6.5535 mW (~ -40 to +8.2 dBm)."
+ ::= { acdSfpThreshEntry 16 }
+
+acdSfpThreshTxPwrHighWarn OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "High Warning TX output power in mW. Represented as a 16 bit unsigned
+ integer with the power defined as the full 16 bit value (0 to 65535)
+ with LSB equal to 0.1 micro-Watt, yielding a total range of 0
+ to 6.5535 mW (~ -40 to +8.2 dBm)."
+ ::= { acdSfpThreshEntry 17 }
+
+acdSfpThreshTxPwrLowWarn OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Low Warning TX output power in mW. Represented as a 16 bit unsigned
+ integer with the power defined as the full 16 bit value (0 to 65535)
+ with LSB equal to 0.1 micro-Watt, yielding a total range of 0
+ to 6.5535 mW (~ -40 to +8.2 dBm)."
+ ::= { acdSfpThreshEntry 18 }
+
+acdSfpThreshRxPwrHighAlm OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "High Alarm RX input power in mW. Represented as a 16 bit unsigned
+ integer with the power defined as the full 16 bit value (0 to 65535)
+ with LSB equal to 0.1 micro-Watt, yielding a total range of 0
+ to 6.5535 mW (~ -40 to +8.2 dBm)."
+ ::= { acdSfpThreshEntry 19 }
+
+acdSfpThreshRxPwrLowAlm OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Low Alarm RX input power in mW. Represented as a 16 bit unsigned
+ integer with the power defined as the full 16 bit value (0 to 65535)
+ with LSB equal to 0.1 micro-Watt, yielding a total range of 0
+ to 6.5535 mW (~ -40 to +8.2 dBm)."
+ ::= { acdSfpThreshEntry 20 }
+
+acdSfpThreshRxPwrHighWarn OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "High Warning RX input power in mW. Represented as a 16 bit unsigned
+ integer with the power defined as the full 16 bit value (0 to 65535)
+ with LSB equal to 0.1 micro-Watt, yielding a total range of 0
+ to 6.5535 mW (~ -40 to +8.2 dBm)."
+ ::= { acdSfpThreshEntry 21 }
+
+acdSfpThreshRxPwrLowWarn OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Low Warning RX input power in mW. Represented as a 16 bit unsigned
+ integer with the power defined as the full 16 bit value (0 to 65535)
+ with LSB equal to 0.1 micro-Watt, yielding a total range of 0
+ to 6.5535 mW (~ -40 to +8.2 dBm)."
+ ::= { acdSfpThreshEntry 22 }
+
+acdSfpThreshTxPwrHighAlmdBm OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "High Alarm TX output power in dBm (~ -40 to +8.2 dBm)."
+ ::= { acdSfpThreshEntry 23 }
+
+acdSfpThreshTxPwrLowAlmdBm OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Low Alarm TX output power in dBm (~ -40 to +8.2 dBm)."
+ ::= { acdSfpThreshEntry 24 }
+
+acdSfpThreshTxPwrHighWarndBm OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "High Warning TX output power in dBm (~ -40 to +8.2 dBm)."
+ ::= { acdSfpThreshEntry 25 }
+
+acdSfpThreshTxPwrLowWarndBm OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Low Warning TX output power in dBm (~ -40 to +8.2 dBm)."
+ ::= { acdSfpThreshEntry 26 }
+
+acdSfpThreshRxPwrHighAlmdBm OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "High Alarm Rx input power in dBm (~ -40 to +8.2 dBm)."
+ ::= { acdSfpThreshEntry 27 }
+
+acdSfpThreshRxPwrLowAlmdBm OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Low Alarm Rx input power in dBm (~ -40 to +8.2 dBm)."
+ ::= { acdSfpThreshEntry 28 }
+
+acdSfpThreshRxPwrHighWarndBm OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "High Warning Rx input power in dBm (~ -40 to +8.2 dBm)."
+ ::= { acdSfpThreshEntry 29 }
+
+acdSfpThreshRxPwrLowWarndBm OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Low Warning Rx input power in dBm (~ -40 to +8.2 dBm)."
+ ::= { acdSfpThreshEntry 30 }
+
+------------------------------------------------------------------------------
+ -- The Alarm and Warning Thresholds SFP Status table
+ -- This table contains all statuses for the SFP Alarm and Warning Thresholds.
+------------------------------------------------------------------------------
+
+acdSfpThreshStatusTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AcdSfpThreshStatusEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of all SFP Digital Diagnostics Thresholds statuses"
+ ::= { acdSfp 4 }
+
+acdSfpThreshStatusEntry OBJECT-TYPE
+ SYNTAX AcdSfpThreshStatusEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This is a part the content of the SFP's 0xA2 EEPROM"
+ INDEX { acdSfpThreshStatusID }
+ ::= { acdSfpThreshStatusTable 1 }
+
+
+AcdSfpThreshStatusEntry ::= SEQUENCE {
+ acdSfpThreshStatusID Unsigned32,
+ acdSfpThreshStatusConnIdx Unsigned32,
+ acdSfpThreshStatusTempHighAlm TruthValue,
+ acdSfpThreshStatusTempLowAlm TruthValue,
+ acdSfpThreshStatusTempHighWarn TruthValue,
+ acdSfpThreshStatusTempLowWarn TruthValue,
+ acdSfpThreshStatusVccHighAlm TruthValue,
+ acdSfpThreshStatusVccLowAlm TruthValue,
+ acdSfpThreshStatusVccHighWarn TruthValue,
+ acdSfpThreshStatusVccLowWarn TruthValue,
+ acdSfpThreshStatusLbcHighAlm TruthValue,
+ acdSfpThreshStatusLbcLowAlm TruthValue,
+ acdSfpThreshStatusLbcHighWarn TruthValue,
+ acdSfpThreshStatusLbcLowWarn TruthValue,
+ acdSfpThreshStatusTxPwrHighAlm TruthValue,
+ acdSfpThreshStatusTxPwrLowAlm TruthValue,
+ acdSfpThreshStatusTxPwrHighWarn TruthValue,
+ acdSfpThreshStatusTxPwrLowWarn TruthValue,
+ acdSfpThreshStatusRxPwrHighAlm TruthValue,
+ acdSfpThreshStatusRxPwrLowAlm TruthValue,
+ acdSfpThreshStatusRxPwrHighWarn TruthValue,
+ acdSfpThreshStatusRxPwrLowWarn TruthValue
+}
+
+acdSfpThreshStatusID OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Unique value for each SFP. Its value ranges from 1 to
+ MAXINT (4 bytes). "
+ ::= { acdSfpThreshStatusEntry 1 }
+
+acdSfpThreshStatusConnIdx OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object identifies the connector index on the box. The index
+ is assigned form left to rigth starting with 1."
+ ::= { acdSfpThreshStatusEntry 2 }
+
+acdSfpThreshStatusTempHighAlm OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This is to indicate if the temperature reaches or overpasses the High
+ alarm threshold."
+ ::= { acdSfpThreshStatusEntry 3 }
+
+acdSfpThreshStatusTempLowAlm OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This is to indicate if the temperature reaches or underpasses the Low
+ alarm threshold."
+ ::= { acdSfpThreshStatusEntry 4 }
+
+acdSfpThreshStatusTempHighWarn OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This is to indicate if the temperature reaches or overpasses the High
+ warning threshold."
+ ::= { acdSfpThreshStatusEntry 5 }
+
+acdSfpThreshStatusTempLowWarn OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This is to indicate if the temperature reaches or underpasses the Low
+ warning threshold."
+ ::= { acdSfpThreshStatusEntry 6 }
+
+acdSfpThreshStatusVccHighAlm OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This is to indicate if the supply voltage reaches or overpasses the High
+ alarm threshold."
+ ::= { acdSfpThreshStatusEntry 7 }
+
+acdSfpThreshStatusVccLowAlm OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This is to indicate if the supply voltage reaches or underpasses the Low
+ alarm threshold."
+ ::= { acdSfpThreshStatusEntry 8 }
+
+acdSfpThreshStatusVccHighWarn OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This is to indicate if the supply voltage reaches or overpasses the High
+ warning threshold."
+ ::= { acdSfpThreshStatusEntry 9 }
+
+acdSfpThreshStatusVccLowWarn OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This is to indicate if the supply voltage reaches or underpasses the Low
+ warning threshold."
+ ::= { acdSfpThreshStatusEntry 10 }
+
+acdSfpThreshStatusLbcHighAlm OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This is to indicate if the Laser Bias Current reaches or overpasses
+ the High alarm threshold."
+ ::= { acdSfpThreshStatusEntry 11 }
+
+acdSfpThreshStatusLbcLowAlm OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This is to indicate if the Laser Bias Current reaches or underpasses
+ the Low alarm threshold."
+ ::= { acdSfpThreshStatusEntry 12 }
+
+acdSfpThreshStatusLbcHighWarn OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This is to indicate if the Laser Bias Current reaches or overpasses
+ the High warning threshold."
+ ::= { acdSfpThreshStatusEntry 13 }
+
+acdSfpThreshStatusLbcLowWarn OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This is to indicate if the Laser Bias Current reaches or underpasses
+ the Low warning threshold."
+ ::= { acdSfpThreshStatusEntry 14 }
+
+acdSfpThreshStatusTxPwrHighAlm OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This is to indicate if the Transmit Power reaches or overpasses the High
+ alarm threshold."
+ ::= { acdSfpThreshStatusEntry 15 }
+
+acdSfpThreshStatusTxPwrLowAlm OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This is to indicate if the Transmit Power reaches or underpasses the Low
+ alarm threshold."
+ ::= { acdSfpThreshStatusEntry 16 }
+
+acdSfpThreshStatusTxPwrHighWarn OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This is to indicate if the Transmit Power reaches or overpasses the High
+ warning threshold."
+ ::= { acdSfpThreshStatusEntry 17 }
+
+acdSfpThreshStatusTxPwrLowWarn OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This is to indicate if the Transmit Power reaches or underpasses the Low
+ warning threshold."
+ ::= { acdSfpThreshStatusEntry 18 }
+
+acdSfpThreshStatusRxPwrHighAlm OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This is to indicate if the Receive Power reaches or overpasses the High
+ alarm threshold."
+ ::= { acdSfpThreshStatusEntry 19 }
+
+acdSfpThreshStatusRxPwrLowAlm OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This is to indicate if the Receive Power reaches or underpasses the Low
+ alarm threshold."
+ ::= { acdSfpThreshStatusEntry 20 }
+
+acdSfpThreshStatusRxPwrHighWarn OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This is to indicate if the Receive Power reaches or overpasses the High
+ warning threshold."
+ ::= { acdSfpThreshStatusEntry 21 }
+
+acdSfpThreshStatusRxPwrLowWarn OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This is to indicate if the Receive Power reaches or underpasses the Low
+ warning threshold."
+ ::= { acdSfpThreshStatusEntry 22 }
+
+---------------------------------------------------------------------------
+ -- ACD-SFP-MIB Module - Conformance Information
+---------------------------------------------------------------------------
+
+acdSfpCompliances OBJECT IDENTIFIER ::= { acdSfpConformance 1 }
+acdSfpGroups OBJECT IDENTIFIER ::= { acdSfpConformance 2 }
+
+---------------------------------------------------------------------------
+ -- Units of conformance
+---------------------------------------------------------------------------
+
+acdSfpInfoGroup OBJECT-GROUP
+ OBJECTS {
+ acdSfpInfoConnIdx,
+ acdSfpInfoConnType,
+ acdSfpInfoVendor,
+ acdSfpInfoVendorOui,
+ acdSfpInfoVendorPn,
+ acdSfpInfoVendorRev,
+ acdSfpInfoWavelength,
+ acdSfpInfoSerialNum,
+ acdSfpInfoYear,
+ acdSfpInfoMonth,
+ acdSfpInfoDay,
+ acdSfpInfoLot,
+ acdSfpInfoRev8472,
+ acdSfpInfoPresent,
+ acdSfpInfoDiag,
+ acdSfpInfoInternal,
+ acdSfpInfoAlm,
+ acdSfpInfoIdType,
+ acdSfpInfoExtIdType,
+ acdSfpInfoTransCode
+ }
+ STATUS current
+ DESCRIPTION
+ "Objects for the SFP information Group."
+ ::= { acdSfpGroups 1 }
+
+acdSfpDiagGroup OBJECT-GROUP
+ OBJECTS {
+ acdSfpDiagConnIdx,
+ acdSfpDiagTemp,
+ acdSfpDiagVcc,
+ acdSfpDiagLbc,
+ acdSfpDiagTxPwr,
+ acdSfpDiagRxPwr,
+ acdSfpDiagTxPwrdBm,
+ acdSfpDiagRxPwrdBm
+ }
+ STATUS current
+ DESCRIPTION
+ "Objects for the SFP diagnostics Group."
+ ::= { acdSfpGroups 2 }
+
+acdSfpThreshGroup OBJECT-GROUP
+ OBJECTS {
+ acdSfpThreshConnIdx,
+ acdSfpThreshTempHighAlm,
+ acdSfpThreshTempLowAlm,
+ acdSfpThreshTempHighWarn,
+ acdSfpThreshTempLowWarn,
+ acdSfpThreshVccHighAlm,
+ acdSfpThreshVccLowAlm,
+ acdSfpThreshVccHighWarn,
+ acdSfpThreshVccLowWarn,
+ acdSfpThreshLbcHighAlm,
+ acdSfpThreshLbcLowAlm,
+ acdSfpThreshLbcHighWarn,
+ acdSfpThreshLbcLowWarn,
+ acdSfpThreshTxPwrHighAlm,
+ acdSfpThreshTxPwrLowAlm,
+ acdSfpThreshTxPwrHighWarn,
+ acdSfpThreshTxPwrLowWarn,
+ acdSfpThreshRxPwrHighAlm,
+ acdSfpThreshRxPwrLowAlm,
+ acdSfpThreshRxPwrHighWarn,
+ acdSfpThreshRxPwrLowWarn,
+ acdSfpThreshTxPwrHighAlmdBm,
+ acdSfpThreshTxPwrLowAlmdBm,
+ acdSfpThreshTxPwrHighWarndBm,
+ acdSfpThreshTxPwrLowWarndBm,
+ acdSfpThreshRxPwrHighAlmdBm,
+ acdSfpThreshRxPwrLowAlmdBm,
+ acdSfpThreshRxPwrHighWarndBm,
+ acdSfpThreshRxPwrLowWarndBm
+ }
+ STATUS current
+ DESCRIPTION
+ "Objects for the SFP thresholds Group."
+ ::= { acdSfpGroups 3 }
+
+acdSfpThreshStatusGroup OBJECT-GROUP
+ OBJECTS {
+ acdSfpThreshStatusConnIdx,
+ acdSfpThreshStatusTempHighAlm,
+ acdSfpThreshStatusTempLowAlm,
+ acdSfpThreshStatusTempHighWarn,
+ acdSfpThreshStatusTempLowWarn,
+ acdSfpThreshStatusVccHighAlm,
+ acdSfpThreshStatusVccLowAlm,
+ acdSfpThreshStatusVccHighWarn,
+ acdSfpThreshStatusVccLowWarn,
+ acdSfpThreshStatusLbcHighAlm,
+ acdSfpThreshStatusLbcLowAlm,
+ acdSfpThreshStatusLbcHighWarn,
+ acdSfpThreshStatusLbcLowWarn,
+ acdSfpThreshStatusTxPwrHighAlm,
+ acdSfpThreshStatusTxPwrLowAlm,
+ acdSfpThreshStatusTxPwrHighWarn,
+ acdSfpThreshStatusTxPwrLowWarn,
+ acdSfpThreshStatusRxPwrHighAlm,
+ acdSfpThreshStatusRxPwrLowAlm,
+ acdSfpThreshStatusRxPwrHighWarn,
+ acdSfpThreshStatusRxPwrLowWarn
+ }
+ STATUS current
+ DESCRIPTION
+ "Objects for the SFP threshold status Group."
+ ::= { acdSfpGroups 4 }
+
+acdSfpCompliance MODULE-COMPLIANCE
+ STATUS current
+ DESCRIPTION
+ "The compliance statement for support of the ACD-SFP-MIB module."
+ MODULE
+ MANDATORY-GROUPS {
+ acdSfpInfoGroup,
+ acdSfpDiagGroup,
+ acdSfpThreshGroup,
+ acdSfpThreshStatusGroup
+ }
+
+ ::= { acdSfpCompliances 1 }
+
+END