summaryrefslogtreecommitdiff
path: root/MIBS/adva/F3-FPM-MIB
diff options
context:
space:
mode:
Diffstat (limited to 'MIBS/adva/F3-FPM-MIB')
-rw-r--r--MIBS/adva/F3-FPM-MIB6832
1 files changed, 6832 insertions, 0 deletions
diff --git a/MIBS/adva/F3-FPM-MIB b/MIBS/adva/F3-FPM-MIB
new file mode 100644
index 0000000..0e8bd43
--- /dev/null
+++ b/MIBS/adva/F3-FPM-MIB
@@ -0,0 +1,6832 @@
+F3-FPM-MIB DEFINITIONS ::= BEGIN
+
+IMPORTS
+ MODULE-COMPLIANCE, OBJECT-GROUP
+ FROM SNMPv2-CONF
+ MODULE-IDENTITY, OBJECT-TYPE, Integer32, Unsigned32, Counter64
+ FROM SNMPv2-SMI
+ TruthValue, RowStatus, StorageType,
+ VariablePointer, TEXTUAL-CONVENTION, DisplayString, DateAndTime
+ FROM SNMPv2-TC
+ VlanId, AdminState, OperationalState, SecondaryState,
+ VlanPriority, CmPmIntervalType, PerfCounter64, CmPmBinAction
+ FROM CM-COMMON-MIB
+ neIndex, shelfIndex, slotIndex
+ FROM CM-ENTITY-MIB
+ cmEthernetAccPortIndex, ShapingType, FlowVlanActionType,
+ FlowTagControl, PolicerAlgorithmType, PolicerColorMode,
+ cmMPFlowEntry, CmControlProtocolDispType, CmActiveControlProtocolsType,
+ cmEthernetNetPortIndex, cmMPFlowIndex
+ FROM CM-FACILITY-MIB
+ fsp150cm
+ FROM ADVA-MIB
+ ProtectLearningControl, LearningAction, FlowLearningConfigAction
+ FROM F3-BRIDGE-MIB
+ FlowSecState
+ FROM CM-COMMON-MIB;
+
+f3FpmMIB MODULE-IDENTITY
+ LAST-UPDATED "201607110000Z"
+ ORGANIZATION "ADVA Optical Networking"
+ CONTACT-INFO
+ " Jakub Nadolski
+ ADVA Optical Networking, Inc.
+ Tel: +48 58 7716 421
+ E-mail: jnadolski@advaoptical.com
+ Postal: ul. Slaska 35
+ 81-310 Gdynia, Poland"
+ DESCRIPTION
+ "This module defines the Flow Point Model MIB definitions
+ used by the F3 product lines.
+ Copyright (C) ADVA Optical Networking."
+ REVISION "201607110000Z"
+ DESCRIPTION
+ "Notes from release 201607110000Z
+ (1) renamed the type FlowSecureState to FlowSecState
+ Notes from release 201607080000Z
+ (1) added f3AccFlowpointRefConnectGuardFlowObject, f3AccFlowpointSecureBlockingControl, and
+ f3AccFlowpointSecureState to f3AccFlowpointTable
+ (2) added f3NetFlowpointRefConnectGuardFlowObject, f3NetFlowpointSecureBlockingControl,
+ and f3NetFlowpointSecureState to f3NetFlowpoitTable
+ (3) added f3MPFlowRefConnectGuardFlowObject and f3MPFlowSecureState to f3MPFlowExtTable
+ Notes from release 201504210000Z,
+ (1) Ready for release FSP150CC 8.1."
+
+ ::= {fsp150cm 43}
+
+--
+-- OID definitions
+--
+
+f3FpmConfigObjects OBJECT IDENTIFIER ::= {f3FpmMIB 1}
+f3FpmPerfObjects OBJECT IDENTIFIER ::= {f3FpmMIB 2}
+f3FpmPerfNotifications OBJECT IDENTIFIER ::= {f3FpmMIB 3}
+f3FpmConformance OBJECT IDENTIFIER ::= {f3FpmMIB 4}
+
+
+--
+-- Acess Flow Point Table
+--
+f3AccFlowPointTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF F3AccFlowPointEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of entries corresponding to Access Flow Point
+ for configuration purposes."
+ ::= { f3FpmConfigObjects 1 }
+
+f3AccFlowPointEntry OBJECT-TYPE
+ SYNTAX F3AccFlowPointEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A conceptual row in the f3AccFlowPointTable.
+ These entries represent an Access Flow Point.
+ If the Flow Point attached to a lag, the slotIndex should
+ be 255 (255 is used to identify the Flow Point belongs to lag),
+ and the cmEthernetAccPortIndex should be the f3LagIndex."
+
+ INDEX { neIndex, shelfIndex, slotIndex, cmEthernetAccPortIndex, f3AccFlowPointIndex }
+ ::= { f3AccFlowPointTable 1 }
+
+F3AccFlowPointEntry ::= SEQUENCE {
+ f3AccFlowPointIndex Integer32,
+ f3AccFlowPointAlias DisplayString,
+
+ f3AccFlowPointAdminState AdminState,
+ f3AccFlowPointOperationalState OperationalState,
+ f3AccFlowPointSecondaryState SecondaryState,
+
+ f3AccFlowPointAssociatedFlowId VariablePointer,
+
+ f3AccFlowPointIngressMultiCOSEnabled TruthValue,
+ f3AccFlowPointIngressCOS Integer32,
+ f3AccFlowPointEgressShapingType ShapingType,
+
+ f3AccFlowPointIngressVlanMemberList DisplayString,
+ f3AccFlowPointVlanMemberAction FlowVlanActionType,
+ f3AccFlowPointVlanMemberActionVlan DisplayString,
+ f3AccFlowPointIngressUntaggedFrameEnabled TruthValue,
+
+ f3AccFlowPointCTagControl FlowTagControl,
+ f3AccFlowPointCTagVlanId VlanId,
+ f3AccFlowPointCTagVlanPriority VlanPriority,
+ f3AccFlowPointSTagControl FlowTagControl,
+ f3AccFlowPointSTagVlanId VlanId,
+ f3AccFlowPointSTagVlanPriority VlanPriority,
+
+ f3AccFlowPointEgressOuterTagPrioMapEnabled TruthValue,
+ f3AccFlowPointEgressInnerTagPrioMapEnabled TruthValue,
+ f3AccFlowPointSESFramesLossThresholdRatio Integer32,
+ f3AccFlowPointDefaultMemberEnabled TruthValue,
+
+ f3AccFlowPointMcastRateLimitEnabled TruthValue,
+ f3AccFlowPointMcastRateLimitSpeedLo Unsigned32,
+ f3AccFlowPointMcastRateLimitSpeedHi Unsigned32,
+ f3AccFlowPointBcastRateLimitEnabled TruthValue,
+ f3AccFlowPointBcastRateLimitSpeedLo Unsigned32,
+ f3AccFlowPointBcastRateLimitSpeedHi Unsigned32,
+ f3AccFlowPointCombinedRateLimitEnabled TruthValue,
+ f3AccFlowPointCombinedRateLimitSpeedLo Unsigned32,
+ f3AccFlowPointCombinedRateLimitSpeedHi Unsigned32,
+
+ f3AccFlowPointSplitHorizonGroupOID VariablePointer,
+ f3AccFlowPointLoopAvoidance VariablePointer,
+ f3AccFlowPointHierarchicalCOSEnabled TruthValue,
+ f3AccFlowPointMaximumBWLo Unsigned32,
+ f3AccFlowPointMaximumBWHi Unsigned32,
+ f3AccFlowPointGuaranteedBWLo Unsigned32,
+ f3AccFlowPointGuaranteedBWHi Unsigned32,
+ f3AccFlowPointAutoBandwidthConfigEnabled TruthValue,
+ f3AccFlowPointAutoCIRPercentage Integer32,
+ f3AccFlowPointFrameFwdEnabled TruthValue,
+
+ f3AccFlowPointStorageType StorageType,
+ f3AccFlowPointRowStatus RowStatus,
+
+ f3AccFlowPointUsePortPrioMapProfile TruthValue,
+ f3AccFlowPointRefPrioMapProfile VariablePointer,
+ f3AccFlowpointRefConnectGuardFlowObject VariablePointer,
+ f3AccFlowpointSecureBlockingControl TruthValue,
+ f3AccFlowpointSecureState FlowSecState
+}
+
+f3AccFlowPointIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The integer index value corresponding to an Flow Point."
+ ::= { f3AccFlowPointEntry 1 }
+
+f3AccFlowPointAlias OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..64))
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object allows SNMP management entities to provide a
+ circuit identifier with the Flow Point."
+ ::= { f3AccFlowPointEntry 2 }
+
+f3AccFlowPointAdminState OBJECT-TYPE
+ SYNTAX AdminState
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object represents the Administrative State of the Flow Point."
+ ::= { f3AccFlowPointEntry 3 }
+
+f3AccFlowPointOperationalState OBJECT-TYPE
+ SYNTAX OperationalState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object represents the Operational State of the Flow Point."
+ ::= { f3AccFlowPointEntry 4 }
+
+f3AccFlowPointSecondaryState OBJECT-TYPE
+ SYNTAX SecondaryState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object represents the Secondary State of the Flow Point."
+ ::= { f3AccFlowPointEntry 5 }
+
+f3AccFlowPointAssociatedFlowId OBJECT-TYPE
+ SYNTAX VariablePointer
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object provides the association of an Flow with an Flow Point."
+ ::= { f3AccFlowPointEntry 6 }
+
+f3AccFlowPointIngressMultiCOSEnabled OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object allows specification of ingress multiple COS
+ (Class of Service) Flow Point."
+ ::= { f3AccFlowPointEntry 7 }
+
+f3AccFlowPointIngressCOS OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-create
+ STATUS deprecated
+ DESCRIPTION
+ "This object allows specification of ingress COS
+ (Class of Service) Flow Point.
+
+ This attribute has been deprecated and is not supported. The
+ Ingress COS is determined from the flowpoint's associated
+ Priority Mapping Profle."
+ ::= { f3AccFlowPointEntry 8 }
+
+f3AccFlowPointEgressShapingType OBJECT-TYPE
+ SYNTAX ShapingType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object allows specification of Shaping Type for Flow Point.
+ For 8.1.1 release, only flow-based Shaping Type is supported."
+ ::= { f3AccFlowPointEntry 9 }
+
+f3AccFlowPointIngressVlanMemberList OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..512))
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "It allows specification of VLAN members of the Flow Point.
+ VLAN members are comma separated, of the form X-Y where X is the
+ VLAN Id and Y is the VLAN Priority. VLAN members can be of
+ the form X-* or X (vlan X with all priorities), *-Y (all vlans
+ with priority Y), and X1:X2 (range of vlans from X1 to X2,
+ all priorities). Members with specific VLAN Id and specific
+ VLAN Priority are not supported. Once the Flow Point is created,
+ this attribute can only be updated using f3AccFlowPointVlanMemberAction
+ and f3AccFlowPointVlanMemberActionVlan objects."
+ ::= { f3AccFlowPointEntry 10 }
+
+f3AccFlowPointVlanMemberAction OBJECT-TYPE
+ SYNTAX FlowVlanActionType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object allows to add or remove the VLAN members specified by
+ f3AccFlowPointVlanMemberActionVlan object. SNMP manager must first
+ configure the VLAN member to be added/removed in the object
+ f3AccFlowPointVlanMemberActionVlan and then should specify
+ f3AccFlowPointVlanMemberAction on whether to add/remove the specified
+ VLAN member."
+ ::= { f3AccFlowPointEntry 11 }
+
+f3AccFlowPointVlanMemberActionVlan OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..16))
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object allows adding/removing VLAN members to a Flow Point.
+ VLAN member is of the form X-Y where X is the VLAN Id and Y is
+ the VLAN Priority. VLAN members can be of the form X-* (vlan X
+ with all priorities), *-Y (all vlans with priority Y), and X1:X2
+ (range of vlans from X1 to X2, all priorities). Members with
+ specific VLAN Id and specific VLAN Priority are not supported.
+ In order to add/remove VLAN member to a flow, user must specify
+ this object with appropriate VLAN and then
+ invoke f3AccFlowPointVlanMemberAction."
+ ::= { f3AccFlowPointEntry 12 }
+
+f3AccFlowPointIngressUntaggedFrameEnabled OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object allows to specify whether or not the Flow Point
+ supports untagged frame."
+ ::= { f3AccFlowPointEntry 13 }
+
+f3AccFlowPointCTagControl OBJECT-TYPE
+ SYNTAX FlowTagControl
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object allows specification of the tag management
+ operation on the C-TAG. Supported types are 'push', 'pushvid',
+ 'swaptag', 'swapvid' and 'none'. If the type is 'push',
+ the VLAN Id (f3AccFlowPointCTagVlanId) and priority
+ (f3AccFlowPointCTagVlanPriority) are pushed onto the frame;
+ if the type is 'pushvid', only the VLAN Id (12 bits) is pushed,
+ the Priority is copied from incoming tag's priority;
+ if the type is 'swaptag', both VLAN Id and Priority (15 bits)
+ are swapped with the specified f3AccFlowPointCTagVlanId and
+ f3AccFlowPointCTagVlanPriority;
+ if the type is 'swapvid', only the VLAN Id (12 bits) are
+ swapped with the specified f3AccFlowPointCTagVlanId;
+ if the type is 'none', no C-TAG management is performed."
+ ::= { f3AccFlowPointEntry 14 }
+
+f3AccFlowPointCTagVlanId OBJECT-TYPE
+ SYNTAX VlanId
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object allows specification of the VLAN Id to
+ be pushed or swapped, based on the value of
+ f3AccFlowPointIngressCTagControl. It is applicable
+ for 'push', 'swaptag', 'swapvid' and 'pushvid' control types."
+ ::= { f3AccFlowPointEntry 15 }
+
+f3AccFlowPointCTagVlanPriority OBJECT-TYPE
+ SYNTAX VlanPriority
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object allows specification of the VLAN Priority to
+ be pushed or swapped, based on the value of f3AccFlowPointIngressCTagControl.
+ It is applicable for 'push' and 'swaptag' control types."
+ ::= { f3AccFlowPointEntry 16 }
+
+f3AccFlowPointSTagControl OBJECT-TYPE
+ SYNTAX FlowTagControl
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object allows specification of the tag management
+ operation on the S-TAG. Supported types are 'push', 'pushvid',
+ 'swaptag', 'swapvid' and 'none'. If the type is 'push',
+ the VLAN Id (f3AccFlowPointSTagVlanId) and priority
+ (f3AccFlowPointSTagVlanPriority) are pushed onto the frame;
+ if the type is 'pushvid', only the VLAN Id (12 bits) is pushed,
+ the Priority is copied from incoming tag's priority;
+ if the type is 'swaptag', both VLAN Id and Priority (15 bits)
+ are swapped with the specified f3AccFlowPointSTagVlanId and
+ f3AccFlowPointSTagVlanPriority;
+ if the type is 'swapvid', only the VLAN Id (12 bits) are
+ swapped with the specified f3AccFlowPointSTagVlanId;
+ if the type is 'none', no S-TAG management is performed."
+ ::= { f3AccFlowPointEntry 17 }
+
+f3AccFlowPointSTagVlanId OBJECT-TYPE
+ SYNTAX VlanId
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object allows specification of the VLAN Id to
+ be pushed or swapped, based on the value of
+ f3AccFlowPointIngressSTagControl. It is applicable
+ for 'push', 'swaptag', 'swapvid' and 'pushvid' control types."
+ ::= { f3AccFlowPointEntry 18 }
+
+f3AccFlowPointSTagVlanPriority OBJECT-TYPE
+ SYNTAX VlanPriority
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object allows specification of the VLAN Priority to
+ be pushed or swapped, based on the value of
+ f3AccFlowPointIngressSTagControl. It is applicable
+ for 'push' and 'swaptag' control types."
+ ::= { f3AccFlowPointEntry 19 }
+
+f3AccFlowPointEgressOuterTagPrioMapEnabled OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object defines whether to use the Egress Prio
+ Mapping to swap the priority of outer tag. When Enabled,
+ it indicates that the operation specified in the
+ EgressPrioMapTable would be applied to Flow for specified COS.
+ When Disabled,the EgressPrioMapTable operations are ignored
+ for specified Flow COS."
+ ::= { f3AccFlowPointEntry 20 }
+
+f3AccFlowPointEgressInnerTagPrioMapEnabled OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object defines whether to use the Egress Prio
+ Mapping to swap the priority of inner tag. When Enabled,
+ it indicates that the operation specified in the
+ EgressPrioMapTable would be applied to Flow for specified COS.
+ When Disabled, the EgressPrioMapTable operations are ignored
+ for specified Flow COS."
+ ::= { f3AccFlowPointEntry 21 }
+
+f3AccFlowPointSESFramesLossThresholdRatio OBJECT-TYPE
+ SYNTAX Integer32 (0..100)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object is used to specify the frame-loss ratio
+ per flow that starts counting Severely Errored Seconds (SES)
+ on the flowpoint.
+ This functionality is applicable if the flowpoint is monitored
+ using the Y.1731 ESA functionality."
+ ::= { f3AccFlowPointEntry 22 }
+
+f3AccFlowPointDefaultMemberEnabled OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Truth Value means that on this FP, the membership is all the tag
+ packets without match any other membership associated to the port.
+ Untagged means untagged flow. Default only care tagged flow."
+ ::= { f3AccFlowPointEntry 23 }
+
+f3AccFlowPointMcastRateLimitEnabled OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Whether multicast packets need be limited per FP."
+ ::= { f3AccFlowPointEntry 24 }
+
+f3AccFlowPointMcastRateLimitSpeedLo OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The rate limiting for multicast packets per FP. When
+ f3AccFlowPointMcastRateLimitEnabled and the value is 0,
+ it means all multicast frame are dropped. This objects
+ only represents low 32 bits."
+ ::= { f3AccFlowPointEntry 25 }
+
+f3AccFlowPointMcastRateLimitSpeedHi OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The rate limiting for multicast packets per FP. When
+ f3AccFlowPointMcastRateLimitEnabled and the value is 0,
+ it means all multicast frame are dropped. This objects
+ only represents high 32 bits."
+ ::= { f3AccFlowPointEntry 26 }
+
+f3AccFlowPointBcastRateLimitEnabled OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Whether broadcast packets need be limited per FP."
+ ::= { f3AccFlowPointEntry 27 }
+
+f3AccFlowPointBcastRateLimitSpeedLo OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The rate limiting for broadcast packets per FP. When
+ f3AccFlowPointBcastRateLimitEnabled and the value is 0,
+ it means all multicast frame are dropped. This objects
+ only represents low 32 bits."
+ ::= { f3AccFlowPointEntry 28 }
+
+f3AccFlowPointBcastRateLimitSpeedHi OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The rate limiting for broadcast packets per FP. When
+ f3AccFlowPointBcastRateLimitEnabled and the value is 0,
+ it means all multicast frame are dropped. This objects
+ only represents high 32 bits."
+ ::= { f3AccFlowPointEntry 29 }
+
+f3AccFlowPointCombinedRateLimitEnabled OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Whether broadcast and multicast packets need be limited per FP."
+ ::= { f3AccFlowPointEntry 30 }
+
+f3AccFlowPointCombinedRateLimitSpeedLo OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The rate limiting for broadcast and multicast packets per FP.
+ When f3AccFlowPointCombinedRateLimitEnabled is true and the value is 0,
+ it means all broadcast and multicast frame are dropped. This object
+ only represents low 32 bits."
+ ::= { f3AccFlowPointEntry 31 }
+
+f3AccFlowPointCombinedRateLimitSpeedHi OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The rate limiting for broadcast and multicast packets per FP.
+ When f3AccFlowPointCombinedRateLimitEnabled is true and the value is 0,
+ it means all broadcast and multicast frame are dropped. This object
+ only represents high 32 bits."
+ ::= { f3AccFlowPointEntry 32 }
+
+f3AccFlowPointSplitHorizonGroupOID OBJECT-TYPE
+ SYNTAX VariablePointer
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Specifies the Split-Horizon Group OID. If there is no SHG, the value is none."
+ ::= { f3AccFlowPointEntry 33 }
+
+f3AccFlowPointLoopAvoidance OBJECT-TYPE
+ SYNTAX VariablePointer
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "EID of this associated Loop Avoidance protocol entity.
+ A value of NONE indicates there is no loop avoidance protocol.
+ Currently ERP EID is filled when ELAN service is created."
+ ::= { f3AccFlowPointEntry 34 }
+
+f3AccFlowPointHierarchicalCOSEnabled OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Enable or Disable Hierarchical COS shaping (flow shaping)."
+ ::= { f3AccFlowPointEntry 35 }
+
+f3AccFlowPointMaximumBWLo OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This attribute description the Flow Point maximum bandwidth.
+ This object only represents low 32 bits."
+ ::= { f3AccFlowPointEntry 36 }
+
+f3AccFlowPointMaximumBWHi OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This attribute description the Flow Point maximum bandwidth.
+ This object only represents high 32 bits."
+ ::= { f3AccFlowPointEntry 37 }
+
+f3AccFlowPointGuaranteedBWLo OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This attribute description the Flow Point guaranteed bandwidth.
+ This object only represents low 32 bits."
+ ::= { f3AccFlowPointEntry 38 }
+
+f3AccFlowPointGuaranteedBWHi OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This attribute description the Flow Point guaranteed bandwidth.
+ This objects only represents high 32 bits."
+ ::= { f3AccFlowPointEntry 39 }
+
+f3AccFlowPointAutoBandwidthConfigEnabled OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object specifies the shaper bandwidth is automatically adjusted
+ by the system. For a single COS Flow Point, the shaper EIR bandwidth is
+ set to the maximum port bandwidth; the shaper CIR is set to the available
+ port bandwidth multiplied by the value of the f3AccFlowPointAutoCIRPercentage
+ object. For a Hierarchical-COS Flow Point, the f3AccFlowPointMaximumBWLo and
+ f3AccFlowPointMaximumBWHi are set to the maximum port bandwidth;
+ the f3AccFlowPointGuaranteedBWLo and f3AccFlowPointGuaranteedBWHi are set to
+ the available port bandwidth multiplied by the value of the
+ f3AccFlowPointAutoCIRPercentage object. The value of this object must be FALSE
+ when f3AccFlowPointIngressMultiCOSEnabled is TRUE and
+ f3AccFlowPointHierarchicalCOSEnabled is FALSE."
+ ::= { f3AccFlowPointEntry 40 }
+
+f3AccFlowPointAutoCIRPercentage OBJECT-TYPE
+ SYNTAX Integer32 (0..100)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object specifies the percentage of available shaper CIR to be assigned
+ to this Flow Point when f3AccFlowPointAutoBandwidthConfigEnabled is TRUE."
+ ::= { f3AccFlowPointEntry 41 }
+
+f3AccFlowPointFrameFwdEnabled OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "When enabled Flow Point will forward frames it receives. When disabled,
+ the Flow Point will not forward frames it receives."
+ ::= { f3AccFlowPointEntry 42 }
+
+f3AccFlowPointStorageType OBJECT-TYPE
+ SYNTAX StorageType
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The type of storage configured for this entry."
+ ::= { f3AccFlowPointEntry 43 }
+
+f3AccFlowPointRowStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The status of this row.
+ An entry MUST NOT exist in the active state unless all
+ objects in the entry have an appropriate value, as described
+ in the description clause for each writable object.
+
+ The values of f3AccFlowPointRowStatus supported are
+ createAndGo(4) and destroy(6). All mandatory attributes
+ must be specified in a single SNMP SET request with
+ f3AccFlowPointRowStatus value as createAndGo(4).
+ Upon successful row creation, this object has a
+ value of active(1).
+
+ The f3AccFlowPointRowStatus object may be modified if
+ the associated instance of this object is equal to active(1)."
+ ::= { f3AccFlowPointEntry 44 }
+
+f3AccFlowPointUsePortPrioMapProfile OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This indicates whether the flow point is using, if true, the port's
+ Priority Mapping Profile or, if false, is using its own
+ Priority Mapping Profile."
+ ::= { f3AccFlowPointEntry 45 }
+
+f3AccFlowPointRefPrioMapProfile OBJECT-TYPE
+ SYNTAX VariablePointer
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object allows to set priority map profile."
+ ::= { f3AccFlowPointEntry 46 }
+
+f3AccFlowpointRefConnectGuardFlowObject OBJECT-TYPE
+ SYNTAX VariablePointer
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object specifies Mac Sec flow object OID."
+ ::= { f3AccFlowPointEntry 47 }
+
+f3AccFlowpointSecureBlockingControl OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object can be used to enable/disable secure block."
+ ::= { f3AccFlowPointEntry 48 }
+
+f3AccFlowpointSecureState OBJECT-TYPE
+ SYNTAX FlowSecState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object specifies the secure state of this flow."
+ ::= { f3AccFlowPointEntry 49 }
+
+
+--
+-- Access Flow Point QoS Shaper
+--
+f3AccFpQosShaperTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF F3AccFpQosShaperEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of entries corresponding to Access Flow Point
+ Quality of Service Shaper for configuration purposes."
+ ::= { f3FpmConfigObjects 2 }
+
+f3AccFpQosShaperEntry OBJECT-TYPE
+ SYNTAX F3AccFpQosShaperEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A conceptual row in the f3AccFpQosShaperTable.
+ These entries represent an Access Flow Point Quality
+ of Service Shaper."
+ INDEX { neIndex, shelfIndex, slotIndex, cmEthernetAccPortIndex,
+ f3AccFlowPointIndex, f3AccFpQosShaperIndex }
+ ::= { f3AccFpQosShaperTable 1 }
+
+F3AccFpQosShaperEntry ::= SEQUENCE {
+ f3AccFpQosShaperIndex Integer32,
+
+ f3AccFpQosShaperAdminState AdminState,
+ f3AccFpQosShaperOperationalState OperationalState,
+ f3AccFpQosShaperSecondaryState SecondaryState,
+
+ f3AccFpQosShaperCIRLo Unsigned32,
+ f3AccFpQosShaperCIRHi Unsigned32,
+ f3AccFpQosShaperEIRLo Unsigned32,
+ f3AccFpQosShaperEIRHi Unsigned32,
+ f3AccFpQosShaperCBS Unsigned32,
+ f3AccFpQosShaperEBS Unsigned32,
+ f3AccFpQosShaperBufferSize Unsigned32,
+ f3AccFpQosShaperCOS Integer32,
+
+ f3AccFpQosShaperStorageType StorageType,
+ f3AccFpQosShaperRowStatus RowStatus
+}
+
+f3AccFpQosShaperIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..8)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The unique integer index value corresponding to a Quality
+ of Service Shaper."
+ ::= { f3AccFpQosShaperEntry 1 }
+
+f3AccFpQosShaperAdminState OBJECT-TYPE
+ SYNTAX AdminState
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object represents the Administrative State of a Shaper."
+ ::= { f3AccFpQosShaperEntry 2 }
+
+f3AccFpQosShaperOperationalState OBJECT-TYPE
+ SYNTAX OperationalState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object represents the Operational State of a Shaper."
+ ::= { f3AccFpQosShaperEntry 3 }
+
+f3AccFpQosShaperSecondaryState OBJECT-TYPE
+ SYNTAX SecondaryState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object represents the Secondary State of the Shaper."
+ ::= { f3AccFpQosShaperEntry 4 }
+
+f3AccFpQosShaperCIRLo OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object represents the Commited Information Rate (CIR)
+ (Lower 32 bits) of the Shaper."
+ ::= { f3AccFpQosShaperEntry 5 }
+
+f3AccFpQosShaperCIRHi OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object represents the Commited Information Rate (CIR)
+ (Higher 32 bits) of the Shaper."
+ ::= { f3AccFpQosShaperEntry 6 }
+
+f3AccFpQosShaperEIRLo OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object represents the Excess Information Rate (EIR)
+ (Lower 32 bits) of a Shaper."
+ ::= { f3AccFpQosShaperEntry 7 }
+
+f3AccFpQosShaperEIRHi OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object represents the Excess Information Rate (EIR)
+ (Lower 32 bits) of a Shaper."
+ ::= { f3AccFpQosShaperEntry 8 }
+
+f3AccFpQosShaperCBS OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object represents the Commited Burst Size (CBS)
+ of a Shaper."
+ ::= { f3AccFpQosShaperEntry 9 }
+
+f3AccFpQosShaperEBS OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object represents the Excess Burst Size (EBS)
+ of a Shaper."
+ ::= { f3AccFpQosShaperEntry 10 }
+
+f3AccFpQosShaperBufferSize OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object represents the Buffer Size of the Shaper."
+ ::= { f3AccFpQosShaperEntry 11 }
+
+f3AccFpQosShaperCOS OBJECT-TYPE
+ SYNTAX Integer32 (0..7)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object provides the COS (Class of Service) value for
+ the QOS Shaper."
+ ::= { f3AccFpQosShaperEntry 12 }
+
+f3AccFpQosShaperStorageType OBJECT-TYPE
+ SYNTAX StorageType
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The type of storage configured for this entry."
+ ::= { f3AccFpQosShaperEntry 13 }
+
+f3AccFpQosShaperRowStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The status of this row.
+ An entry MUST NOT exist in the active state unless all
+ objects in the entry have an appropriate value, as described
+ in the description clause for each writable object.
+
+ The values of f3AccFpQosShaperRowStatus supported are
+ createAndGo(4) and destroy(6). All mandatory attributes
+ must be specified in a single SNMP SET request with
+ f3AccFpQosShaperRowStatus value as createAndGo(4).
+ Upon successful row creation, this object has a
+ value of active(1).
+
+ The f3AccFpQosShaperRowStatus object may be modified if
+ the associated instance of this object is equal to active(1)."
+ ::= { f3AccFpQosShaperEntry 14 }
+
+--
+-- Access Flow Point QoS Policer
+--
+f3AccFpQosPolicerTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF F3AccFpQosPolicerEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of entries corresponding to Access Flow Point
+ Quality of Service Policer for configuration purposes."
+ ::= { f3FpmConfigObjects 3 }
+
+f3AccFpQosPolicerEntry OBJECT-TYPE
+ SYNTAX F3AccFpQosPolicerEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A conceptual row in the f3AccFpQosPolicerTable.
+ These entries represent an Access Flow Point Quality
+ of Service Policer."
+ INDEX { neIndex, shelfIndex, slotIndex, cmEthernetAccPortIndex,
+ f3AccFlowPointIndex, f3AccFpQosPolicerIndex }
+ ::= { f3AccFpQosPolicerTable 1 }
+
+F3AccFpQosPolicerEntry ::= SEQUENCE {
+ f3AccFpQosPolicerIndex Integer32,
+
+ f3AccFpQosPolicerAdminState AdminState,
+ f3AccFpQosPolicerOperationalState OperationalState,
+ f3AccFpQosPolicerSecondaryState SecondaryState,
+
+ f3AccFpQosPolicerCIRLo Unsigned32,
+ f3AccFpQosPolicerCIRHi Unsigned32,
+ f3AccFpQosPolicerEIRLo Unsigned32,
+ f3AccFpQosPolicerEIRHi Unsigned32,
+ f3AccFpQosPolicerCBS Integer32,
+ f3AccFpQosPolicerEBS Integer32,
+
+ f3AccFpQosPolicerAlgorithm PolicerAlgorithmType,
+ f3AccFpQosPolicerColorMode PolicerColorMode,
+ f3AccFpQosPolicerCouplingFlag TruthValue,
+ f3AccFpQosPolicerPolicingEnabled TruthValue,
+
+ f3AccFpQosPolicerStorageType StorageType,
+ f3AccFpQosPolicerRowStatus RowStatus
+}
+
+f3AccFpQosPolicerIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..8)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The unique integer index value corresponding to a Quality
+ of Service Policer.
+ The Policer Index represents the COS level. This
+ is applicable in case of a Multi COS Flow Point. Index 1
+ represents COS 0; Index 2 represents COS 1 and so on."
+ ::= { f3AccFpQosPolicerEntry 1 }
+
+f3AccFpQosPolicerAdminState OBJECT-TYPE
+ SYNTAX AdminState
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object represents the Administrative State of a Policer."
+ ::= { f3AccFpQosPolicerEntry 2 }
+
+f3AccFpQosPolicerOperationalState OBJECT-TYPE
+ SYNTAX OperationalState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object represents the Operational State of a Policer."
+ ::= { f3AccFpQosPolicerEntry 3 }
+
+f3AccFpQosPolicerSecondaryState OBJECT-TYPE
+ SYNTAX SecondaryState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object represents the Secondary State of a Policer."
+ ::= { f3AccFpQosPolicerEntry 4 }
+
+f3AccFpQosPolicerCIRLo OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object represents the Commited Information Rate (CIR)
+ (Lower 32 bits) of the Policer."
+ ::= { f3AccFpQosPolicerEntry 5 }
+
+f3AccFpQosPolicerCIRHi OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object represents the Commited Information Rate (CIR)
+ (Higher 32 bits) of the Policer."
+ ::= { f3AccFpQosPolicerEntry 6 }
+
+f3AccFpQosPolicerEIRLo OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object represents the Excess Information Rate (EIR)
+ (Lower 32 bits) of a Policer."
+ ::= { f3AccFpQosPolicerEntry 7 }
+
+f3AccFpQosPolicerEIRHi OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object represents the Excess Information Rate (EIR)
+ (Lower 32 bits) of a Policer."
+ ::= { f3AccFpQosPolicerEntry 8 }
+
+f3AccFpQosPolicerCBS OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object represents the Commited Burst Size (CBS)
+ of a Policer."
+ ::= { f3AccFpQosPolicerEntry 9 }
+
+f3AccFpQosPolicerEBS OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object represents the Excess Burst Size (EBS)
+ of a Policer."
+ ::= { f3AccFpQosPolicerEntry 10 }
+
+f3AccFpQosPolicerAlgorithm OBJECT-TYPE
+ SYNTAX PolicerAlgorithmType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object represents Policer algorithm as 'srTCM'
+ (Single Rate Triple Color Marking) or 'trTCM'
+ (Two Rate Triple Color Marking)."
+ ::= { f3AccFpQosPolicerEntry 11 }
+
+f3AccFpQosPolicerColorMode OBJECT-TYPE
+ SYNTAX PolicerColorMode
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object allows specification of Policer Color Mode as
+ 'color-aware' or 'color-blind'."
+ ::= { f3AccFpQosPolicerEntry 12 }
+
+f3AccFpQosPolicerCouplingFlag OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object allows specification of Policer Coupling Flag.
+ When coupling is enabled, tokens that would normally be
+ added to the C-bucket are passed to the E-bucket only once the CIR
+ bucket has reached its CBS level. Therefore under this condition
+ the E-bucket is being filled at the rate of CIR + EIR.
+ Normally the long term average of frames declared yellow is
+ bounded by the EIR. Coupling is a function to allow the
+ long term average of frames declared yellow to be bounded by
+ CIR + EIR. This allows a higher volume of yellow frames
+ to be delivered/received if the arrival of green marked frames
+ is low. Tokens from the E-bucket do NOT get passed to the
+ C-bucket once the EBS level has been reached.
+ Enabling coupling in combination with a provisioned EIR of 0
+ allows for a single rate three color marking (srTCM) algorithm
+ to be established. In this situation the E-bucket is filled at the
+ CIR rate in the case the C-bucket is filled to its CBS level."
+ ::= { f3AccFpQosPolicerEntry 13 }
+
+f3AccFpQosPolicerPolicingEnabled OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object allows specification of Policer Policing.
+ When Policing is disabled, traffic policing is bypassed.
+ When Policing is enabled, traffic policing is applied."
+ ::= { f3AccFpQosPolicerEntry 14 }
+
+f3AccFpQosPolicerStorageType OBJECT-TYPE
+ SYNTAX StorageType
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The type of storage configured for this entry."
+ ::= { f3AccFpQosPolicerEntry 15 }
+
+f3AccFpQosPolicerRowStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The status of this row.
+ An entry MUST NOT exist in the active state unless all
+ objects in the entry have an appropriate value, as described
+ in the description clause for each writable object.
+
+ The values of f3AccFpQosPolicerRowStatus supported are
+ createAndGo(4) and destroy(6). All mandatory attributes
+ must be specified in a single SNMP SET request with
+ f3AccFpQosPolicerRowStatus value as createAndGo(4).
+ Upon successful row creation, this object has a
+ value of active(1).
+
+ The f3AccFpQosPolicerRowStatus object may be modified if
+ the associated instance of this object is equal to active(1)."
+ ::= { f3AccFpQosPolicerEntry 16 }
+
+--
+-- cmMPFlowTable extension for maximum forwarding table size configurations
+--
+f3MPFlowExtTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF F3MPFlowExtEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table extends cmMPFlowTable to provide configuration of maximum
+ forwarding table size."
+ ::= { f3FpmConfigObjects 4 }
+
+f3MPFlowExtEntry OBJECT-TYPE
+ SYNTAX F3MPFlowExtEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A conceptual row in the f3MPFlowExtTable."
+ AUGMENTS { cmMPFlowEntry }
+ ::= { f3MPFlowExtTable 1 }
+
+F3MPFlowExtEntry ::= SEQUENCE {
+ f3MPFlowExtMaxFwdEntries Integer32,
+ f3MPFlowRefConnectGuardFlowObject VariablePointer,
+ f3MPFlowSecureState FlowSecState
+}
+
+f3MPFlowExtMaxFwdEntries OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object allows configuring the maximum number of Forwarding Entires
+ for Forwarding Table of this MP Flow."
+ ::= { f3MPFlowExtEntry 1 }
+
+f3MPFlowRefConnectGuardFlowObject OBJECT-TYPE
+ SYNTAX VariablePointer
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object specifies Mac Sec flow object OID."
+ ::= { f3MPFlowExtEntry 2 }
+
+f3MPFlowSecureState OBJECT-TYPE
+ SYNTAX FlowSecState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object specifies the secure state of the macsec flow."
+ ::= { f3MPFlowExtEntry 3 }
+
+--
+-- Access Flow Point Control Protocol Disposition
+--
+f3AccFlowPointCpdV2Table OBJECT-TYPE
+ SYNTAX SEQUENCE OF F3AccFlowPointCpdV2Entry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of entries corresponding to Access Flow Point
+ Control Protocol Disposition V2."
+ ::= { f3FpmConfigObjects 5 }
+
+f3AccFlowPointCpdV2Entry OBJECT-TYPE
+ SYNTAX F3AccFlowPointCpdV2Entry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A conceptual row in the f3AccFlowPointCpdV2Table.
+ These entries represent a Control Protocol Disposition
+ filtering criteria on the Access Flow Point."
+ INDEX { neIndex, shelfIndex, slotIndex, cmEthernetAccPortIndex,
+ f3AccFlowPointIndex, f3AccFlowPointCpdV2Index }
+ ::= { f3AccFlowPointCpdV2Table 1 }
+
+F3AccFlowPointCpdV2Entry ::= SEQUENCE {
+ f3AccFlowPointCpdV2Index Integer32,
+ f3AccFlowPointCpdV2IslDispType CmControlProtocolDispType,
+ f3AccFlowPointCpdV2PagpDispType CmControlProtocolDispType,
+ f3AccFlowPointCpdV2UdldDispType CmControlProtocolDispType,
+ f3AccFlowPointCpdV2CdpDispType CmControlProtocolDispType,
+ f3AccFlowPointCpdV2VtpDispType CmControlProtocolDispType,
+ f3AccFlowPointCpdV2DtpDispType CmControlProtocolDispType,
+ f3AccFlowPointCpdV2PvstpPlusDispType CmControlProtocolDispType,
+ f3AccFlowPointCpdV2UplinkFastDispType CmControlProtocolDispType,
+ f3AccFlowPointCpdV2VlanBridgeDispType CmControlProtocolDispType,
+ f3AccFlowPointCpdV2L2PTDispType CmControlProtocolDispType,
+ f3AccFlowPointCpdV2BPDUDispType CmControlProtocolDispType,
+ f3AccFlowPointCpdV2PauseDispType CmControlProtocolDispType,
+ f3AccFlowPointCpdV2LACPDispType CmControlProtocolDispType,
+ f3AccFlowPointCpdV2LACPMarkerDispType CmControlProtocolDispType,
+ f3AccFlowPointCpdV2EfmOamDispType CmControlProtocolDispType,
+ f3AccFlowPointCpdV2SSMDispType CmControlProtocolDispType,
+ f3AccFlowPointCpdV2PortAuthenDispType CmControlProtocolDispType,
+ f3AccFlowPointCpdV2LANBridgesDispType CmControlProtocolDispType,
+ f3AccFlowPointCpdV2GMRPDispType CmControlProtocolDispType,
+ f3AccFlowPointCpdV2GVRPDispType CmControlProtocolDispType,
+ f3AccFlowPointCpdV2GARPDispType CmControlProtocolDispType,
+ f3AccFlowPointCpdV2ActiveControlProtocols CmActiveControlProtocolsType,
+ f3AccFlowPointCpdV2ELMIDispType CmControlProtocolDispType,
+ f3AccFlowPointCpdV2Mac00DispType CmControlProtocolDispType,
+ f3AccFlowPointCpdV2Mac01DispType CmControlProtocolDispType,
+ f3AccFlowPointCpdV2Mac02DispType CmControlProtocolDispType,
+ f3AccFlowPointCpdV2Mac03DispType CmControlProtocolDispType,
+ f3AccFlowPointCpdV2Mac04DispType CmControlProtocolDispType,
+ f3AccFlowPointCpdV2Mac05DispType CmControlProtocolDispType,
+ f3AccFlowPointCpdV2Mac06DispType CmControlProtocolDispType,
+ f3AccFlowPointCpdV2Mac07DispType CmControlProtocolDispType,
+ f3AccFlowPointCpdV2Mac08DispType CmControlProtocolDispType,
+ f3AccFlowPointCpdV2Mac09DispType CmControlProtocolDispType,
+ f3AccFlowPointCpdV2Mac0ADispType CmControlProtocolDispType,
+ f3AccFlowPointCpdV2Mac0BDispType CmControlProtocolDispType,
+ f3AccFlowPointCpdV2Mac0CDispType CmControlProtocolDispType,
+ f3AccFlowPointCpdV2Mac0DDispType CmControlProtocolDispType,
+ f3AccFlowPointCpdV2Mac0EDispType CmControlProtocolDispType,
+ f3AccFlowPointCpdV2Mac0FDispType CmControlProtocolDispType,
+ f3AccFlowPointCpdV2NearestLLDPDispType CmControlProtocolDispType,
+ f3AccFlowPointCpdV2NonTpmrLLDPDispType CmControlProtocolDispType,
+ f3AccFlowPointCpdV2CustomerLLDPDispType CmControlProtocolDispType
+}
+
+f3AccFlowPointCpdV2Index OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Unique Index value to access the CPD row."
+ ::= { f3AccFlowPointCpdV2Entry 1 }
+
+f3AccFlowPointCpdV2IslDispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Control Protocol Disposition for ISL (Inter Switch Link).
+ MAC Address (01:00:0C:00:00:00)."
+ ::= { f3AccFlowPointCpdV2Entry 2 }
+
+f3AccFlowPointCpdV2PagpDispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Control Protocol Disposition for PAGP (Port Aggregation Protocol).
+ MAC Address (01:00:0C:CC:CC:CC), Ethertype(0x104)."
+ ::= { f3AccFlowPointCpdV2Entry 3 }
+
+f3AccFlowPointCpdV2UdldDispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Control Protocol Disposition for UDLD (Unidirectional Link Detection).
+ MAC Address (01:00:0C:CC:CC:CC), Ethertype(0x111)."
+ ::= { f3AccFlowPointCpdV2Entry 4 }
+
+f3AccFlowPointCpdV2CdpDispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Control Protocol Disposition for CDP (Cisco Discovery Protocol).
+ MAC Address (01:00:0C:CC:CC:CC), Ethertype(0x2000)."
+ ::= { f3AccFlowPointCpdV2Entry 5 }
+
+f3AccFlowPointCpdV2VtpDispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Control Protocol Disposition for VTP (VLAN Trunking Protocol).
+ MAC Address (01:00:0C:CC:CC:CC), Ethertype(0x2003)."
+ ::= { f3AccFlowPointCpdV2Entry 6 }
+
+f3AccFlowPointCpdV2DtpDispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Control Protocol Disposition for DTP (Dynamic Trunking).
+ MAC Address (01:00:0C:CC:CC:CC), Ethertype(0x2004)."
+ ::= { f3AccFlowPointCpdV2Entry 7 }
+
+f3AccFlowPointCpdV2PvstpPlusDispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Control Protocol Disposition for Spanning Tree PVSTP+.
+ MAC Address (01:00:0C:CC:CC:CC), Ethertype(0x10B)."
+ ::= { f3AccFlowPointCpdV2Entry 8 }
+
+f3AccFlowPointCpdV2UplinkFastDispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Control Protocol Disposition for STP UplinkFast.
+ MAC Address (01:00:0C:CD:CD:CD), Ethertype(0x200A)."
+ ::= { f3AccFlowPointCpdV2Entry 9 }
+
+f3AccFlowPointCpdV2VlanBridgeDispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Control Protocol Disposition for VLAN Bridge.
+ MAC Address (01:00:0C:CD:CD:CE), Ethertype(0x10C)."
+ ::= { f3AccFlowPointCpdV2Entry 10 }
+
+f3AccFlowPointCpdV2L2PTDispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Control Protocol Disposition for Layer 2 Protocol Tunnelling(L2PT).
+ MAC Address (01:00:0C:CD:CD:D0)."
+ ::= { f3AccFlowPointCpdV2Entry 11 }
+
+f3AccFlowPointCpdV2BPDUDispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Control Protocol Disposition for IEEE Spanning Tree(STP),
+ MSTP (Multiple Spanning Tree) and RSTP (Rapid Reconfiguration of
+ Spanning Tree). MAC Address (01:80:C2:00:00:00)."
+ ::= { f3AccFlowPointCpdV2Entry 12 }
+
+f3AccFlowPointCpdV2PauseDispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Control Protocol Disposition for IEEE 802.3x Flow Control
+ (PAUSE frames)."
+ ::= { f3AccFlowPointCpdV2Entry 13 }
+
+f3AccFlowPointCpdV2LACPDispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Control Protocol Disposition for 802.3ad Link Aggregation
+ Protocol.
+ MAC Address (01:80:C2:00:00:03), Ethertype (0x8809), Subtype(01)."
+ ::= { f3AccFlowPointCpdV2Entry 14 }
+
+f3AccFlowPointCpdV2LACPMarkerDispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Control Protocol Disposition for IEEE 802.3ad Marker Protocol.
+ MAC Address (01:80:C2:00:00:03), Ethertype (0x8809), Subtype(02)."
+ ::= { f3AccFlowPointCpdV2Entry 15 }
+
+f3AccFlowPointCpdV2EfmOamDispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Control Protocol Disposition for IEEE 802.3ah EFM OAM.
+ MAC Address (01:80:C2:00:00:03), Ethertype (0x8809), Subtype(03)."
+ ::= { f3AccFlowPointCpdV2Entry 16 }
+
+f3AccFlowPointCpdV2SSMDispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Control Protocol Disposition for Sync Status Messages.
+ MAC Address (01:80:C2:00:00:02), Ethertype (0x19A7), Subtype(0A)."
+ ::= { f3AccFlowPointCpdV2Entry 17 }
+
+f3AccFlowPointCpdV2PortAuthenDispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Control Protocol Disposition for IEEE 802.1x Protocol.
+ MAC Address (01:80:C2:00:00:03), Ethertype (0x888E)."
+ ::= { f3AccFlowPointCpdV2Entry 18 }
+
+f3AccFlowPointCpdV2LANBridgesDispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Control Protocol Disposition for IEEE 802.1d LAN Bridge Managment.
+ MAC Address (01:80:C2:00:00:10)."
+ ::= { f3AccFlowPointCpdV2Entry 19 }
+
+f3AccFlowPointCpdV2GMRPDispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Control Protocol Disposition for GARP Multicast Registration
+ Protocol. MAC Address (01:80:C2:00:00:20)."
+ ::= { f3AccFlowPointCpdV2Entry 20 }
+
+f3AccFlowPointCpdV2GVRPDispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Control Protocol Disposition for GARP VLAN Registration
+ Protocol. MAC Address (01:80:C2:00:00:21)."
+ ::= { f3AccFlowPointCpdV2Entry 21 }
+
+f3AccFlowPointCpdV2GARPDispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Group Disposition type which includes GARP Reserved
+ MAC Address from range 01:80:C2:00:00:22 to 01:80:C2:00:00:2F."
+ ::= { f3AccFlowPointCpdV2Entry 22 }
+
+f3AccFlowPointCpdV2ActiveControlProtocols OBJECT-TYPE
+ SYNTAX CmActiveControlProtocolsType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "List of Active Control Protocol Dispositions. Note that
+ if the Port Level Disposition control is set to PEER or
+ DISCARD, the flow level disposition is no longer active.
+ This object provides information on all the active
+ dispositions."
+ ::= { f3AccFlowPointCpdV2Entry 23 }
+
+f3AccFlowPointCpdV2ELMIDispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ELMI (Ethernet Local Management Interface) Disposition type.
+ MAC Address 01:80:C2:00:00:07 and EtherType of 0x88EE."
+ ::= { f3AccFlowPointCpdV2Entry 24 }
+
+f3AccFlowPointCpdV2Mac00DispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "MAC Address 01:80:C2:00:00:00 Disposition type."
+ ::= { f3AccFlowPointCpdV2Entry 25 }
+
+f3AccFlowPointCpdV2Mac01DispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "MAC Address 01:80:C2:00:00:01 Disposition type."
+ ::= { f3AccFlowPointCpdV2Entry 26 }
+
+f3AccFlowPointCpdV2Mac02DispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "MAC Address 01:80:C2:00:00:02 Disposition type."
+ ::= { f3AccFlowPointCpdV2Entry 27 }
+
+f3AccFlowPointCpdV2Mac03DispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "MAC Address 01:80:C2:00:00:03 Disposition type."
+ ::= { f3AccFlowPointCpdV2Entry 28 }
+
+f3AccFlowPointCpdV2Mac04DispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "MAC Address 01:80:C2:00:00:04 Disposition type."
+ ::= { f3AccFlowPointCpdV2Entry 29 }
+
+f3AccFlowPointCpdV2Mac05DispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "MAC Address 01:80:C2:00:00:05 Disposition type."
+ ::= { f3AccFlowPointCpdV2Entry 30 }
+
+f3AccFlowPointCpdV2Mac06DispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "MAC Address 01:80:C2:00:00:06 Disposition type."
+ ::= { f3AccFlowPointCpdV2Entry 31 }
+
+f3AccFlowPointCpdV2Mac07DispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "MAC Address 01:80:C2:00:00:07 Disposition type."
+ ::= { f3AccFlowPointCpdV2Entry 32 }
+
+f3AccFlowPointCpdV2Mac08DispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "MAC Address 01:80:C2:00:00:08 Disposition type."
+ ::= { f3AccFlowPointCpdV2Entry 33 }
+
+f3AccFlowPointCpdV2Mac09DispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "MAC Address 01:80:C2:00:00:09 Disposition type."
+ ::= { f3AccFlowPointCpdV2Entry 34 }
+
+f3AccFlowPointCpdV2Mac0ADispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "MAC Address 01:80:C2:00:00:0A Disposition type."
+ ::= { f3AccFlowPointCpdV2Entry 35 }
+
+f3AccFlowPointCpdV2Mac0BDispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "MAC Address 01:80:C2:00:00:0B Disposition type."
+ ::= { f3AccFlowPointCpdV2Entry 36 }
+
+f3AccFlowPointCpdV2Mac0CDispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "MAC Address 01:80:C2:00:00:0C Disposition type."
+ ::= { f3AccFlowPointCpdV2Entry 37 }
+
+f3AccFlowPointCpdV2Mac0DDispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "MAC Address 01:80:C2:00:00:0D Disposition type."
+ ::= { f3AccFlowPointCpdV2Entry 38 }
+
+f3AccFlowPointCpdV2Mac0EDispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "MAC Address 01:80:C2:00:00:0E Disposition type."
+ ::= { f3AccFlowPointCpdV2Entry 39 }
+
+f3AccFlowPointCpdV2Mac0FDispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "MAC Address 01:80:C2:00:00:0F Disposition type."
+ ::= { f3AccFlowPointCpdV2Entry 40 }
+
+f3AccFlowPointCpdV2NearestLLDPDispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "LLDP (Link Layer Discovery Protocol) Nearest Bridge Disposition type."
+ ::= { f3AccFlowPointCpdV2Entry 41 }
+
+f3AccFlowPointCpdV2NonTpmrLLDPDispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "LLDP (Link Layer Discovery Protocol) Non-TPMR Bridge Disposition type."
+ ::= { f3AccFlowPointCpdV2Entry 42 }
+
+f3AccFlowPointCpdV2CustomerLLDPDispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "LLDP (Link Layer Discovery Protocol) Customer Bridge Disposition type."
+ ::= { f3AccFlowPointCpdV2Entry 43 }
+
+--
+-- Access Flowpoint table extension for Learning Control configuration
+--
+f3AccFlowPointLearningConfigTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF F3AccFlowPointLearningConfigEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table extends f3AccFlowPointTable to provide parameters for MAC Table control
+ configuration."
+ ::= { f3FpmConfigObjects 6 }
+
+f3AccFlowPointLearningConfigEntry OBJECT-TYPE
+ SYNTAX F3AccFlowPointLearningConfigEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A conceptual row in the f3AccFlowPointLearningConfigTable."
+ AUGMENTS { f3AccFlowPointEntry }
+ ::= { f3AccFlowPointLearningConfigTable 1 }
+
+F3AccFlowPointLearningConfigEntry ::= SEQUENCE {
+ f3AccFlowPointLearningConfigLearningEnabled TruthValue,
+ f3AccFlowPointLearningConfigMaxFwdEntries Integer32,
+ f3AccFlowPointLearningConfigProtectLearningCtrl ProtectLearningControl,
+ f3AccFlowPointLearningConfigAction FlowLearningConfigAction
+}
+
+f3AccFlowPointLearningConfigLearningEnabled OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object allows configuring Learning Control on this Flowpoint."
+ ::= { f3AccFlowPointLearningConfigEntry 1 }
+
+f3AccFlowPointLearningConfigMaxFwdEntries OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object allows configuring the maximum number of Forwarding Entries
+ on this Flowpoint."
+ ::= { f3AccFlowPointLearningConfigEntry 2 }
+
+f3AccFlowPointLearningConfigProtectLearningCtrl OBJECT-TYPE
+ SYNTAX ProtectLearningControl
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object allows configuring Learning Control on this Flowpoint."
+ ::= { f3AccFlowPointLearningConfigEntry 3 }
+
+f3AccFlowPointLearningConfigAction OBJECT-TYPE
+ SYNTAX FlowLearningConfigAction
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This objects allows performing user action on Flow Learning Table."
+ ::= { f3AccFlowPointLearningConfigEntry 4 }
+
+--
+-- Network Flow Point Table
+--
+
+f3NetFlowPointTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF F3NetFlowPointEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of entries corresponding to Network Flow Point
+ for configuration purposes."
+ ::= { f3FpmConfigObjects 7 }
+
+f3NetFlowPointEntry OBJECT-TYPE
+ SYNTAX F3NetFlowPointEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A conceptual row in the f3NetFlowPointTable.
+ These entries represent an Network Flow Point.
+ If the Flow Point attached to a lag, the slotIndex should
+ be 255 (255 is used to identify the Flow Point belongs to lag),
+ and the cmEthernetNetPortIndex should be the f3LagIndex."
+
+ INDEX { neIndex, shelfIndex, slotIndex, cmEthernetNetPortIndex, f3NetFlowPointIndex }
+ ::= { f3NetFlowPointTable 1 }
+
+F3NetFlowPointEntry ::= SEQUENCE {
+ f3NetFlowPointIndex Integer32,
+ f3NetFlowPointAlias DisplayString,
+
+ f3NetFlowPointAdminState AdminState,
+ f3NetFlowPointOperationalState OperationalState,
+ f3NetFlowPointSecondaryState SecondaryState,
+
+ f3NetFlowPointAssociatedFlowId VariablePointer,
+
+ f3NetFlowPointIngressMultiCOSEnabled TruthValue,
+ f3NetFlowPointIngressCOS Integer32,
+ f3NetFlowPointEgressShapingType ShapingType,
+
+ f3NetFlowPointIngressVlanMemberList DisplayString,
+ f3NetFlowPointVlanMemberAction FlowVlanActionType,
+ f3NetFlowPointVlanMemberActionVlan DisplayString,
+ f3NetFlowPointIngressUntaggedFrameEnabled TruthValue,
+
+ f3NetFlowPointCTagControl FlowTagControl,
+ f3NetFlowPointCTagVlanId VlanId,
+ f3NetFlowPointCTagVlanPriority VlanPriority,
+ f3NetFlowPointSTagControl FlowTagControl,
+ f3NetFlowPointSTagVlanId VlanId,
+ f3NetFlowPointSTagVlanPriority VlanPriority,
+
+ f3NetFlowPointEgressOuterTagPrioMapEnabled TruthValue,
+ f3NetFlowPointEgressInnerTagPrioMapEnabled TruthValue,
+ f3NetFlowPointSESFramesLossThresholdRatio Integer32,
+ f3NetFlowPointDefaultMemberEnabled TruthValue,
+
+ f3NetFlowPointMcastRateLimitEnabled TruthValue,
+ f3NetFlowPointMcastRateLimitSpeedLo Unsigned32,
+ f3NetFlowPointMcastRateLimitSpeedHi Unsigned32,
+ f3NetFlowPointBcastRateLimitEnabled TruthValue,
+ f3NetFlowPointBcastRateLimitSpeedLo Unsigned32,
+ f3NetFlowPointBcastRateLimitSpeedHi Unsigned32,
+ f3NetFlowPointCombinedRateLimitEnabled TruthValue,
+ f3NetFlowPointCombinedRateLimitSpeedLo Unsigned32,
+ f3NetFlowPointCombinedRateLimitSpeedHi Unsigned32,
+
+ f3NetFlowPointSplitHorizonGroupOID VariablePointer,
+ f3NetFlowPointLoopAvoidance VariablePointer,
+ f3NetFlowPointHierarchicalCOSEnabled TruthValue,
+ f3NetFlowPointMaximumBWLo Unsigned32,
+ f3NetFlowPointMaximumBWHi Unsigned32,
+ f3NetFlowPointGuaranteedBWLo Unsigned32,
+ f3NetFlowPointGuaranteedBWHi Unsigned32,
+ f3NetFlowPointAutoBandwidthConfigEnabled TruthValue,
+ f3NetFlowPointAutoCIRPercentage Integer32,
+ f3NetFlowPointFrameFwdEnabled TruthValue,
+
+ f3NetFlowPointStorageType StorageType,
+ f3NetFlowPointRowStatus RowStatus,
+
+ f3NetFlowPointUsePortPrioMapProfile TruthValue,
+ f3NetFlowPointRefPrioMapProfile VariablePointer,
+ f3NetFlowpointRefConnectGuardFlowObject VariablePointer,
+ f3NetFlowpointSecureBlockingControl TruthValue,
+ f3NetFlowpointSecureState FlowSecState
+}
+
+f3NetFlowPointIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The integer index value corresponding to an Flow Point."
+ ::= { f3NetFlowPointEntry 1 }
+
+f3NetFlowPointAlias OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..64))
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object allows SNMP management entities to provide a
+ circuit identifier with the Flow Point."
+ ::= { f3NetFlowPointEntry 2 }
+
+f3NetFlowPointAdminState OBJECT-TYPE
+ SYNTAX AdminState
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object represents the Administrative State of the Flow Point."
+ ::= { f3NetFlowPointEntry 3 }
+
+f3NetFlowPointOperationalState OBJECT-TYPE
+ SYNTAX OperationalState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object represents the Operational State of the Flow Point."
+ ::= { f3NetFlowPointEntry 4 }
+
+f3NetFlowPointSecondaryState OBJECT-TYPE
+ SYNTAX SecondaryState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object represents the Secondary State of the Flow Point."
+ ::= { f3NetFlowPointEntry 5 }
+
+f3NetFlowPointAssociatedFlowId OBJECT-TYPE
+ SYNTAX VariablePointer
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object provides the association of an Flow with an Flow Point."
+ ::= { f3NetFlowPointEntry 6 }
+
+f3NetFlowPointIngressMultiCOSEnabled OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object allows specification of ingress multiple COS
+ (Class of Service) Flow Point."
+ ::= { f3NetFlowPointEntry 7 }
+
+f3NetFlowPointIngressCOS OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-create
+ STATUS deprecated
+ DESCRIPTION
+ "This object allows specification of ingress COS
+ (Class of Service) Flow Point.
+
+ This attribute has been deprecated and is not supported. The
+ Ingress COS is determined from the flowpoint's associated
+ Priority Mapping Profle."
+ ::= { f3NetFlowPointEntry 8 }
+
+f3NetFlowPointEgressShapingType OBJECT-TYPE
+ SYNTAX ShapingType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object allows specification of Shaping Type for Flow Point.
+ For 8.1.1 release, only flow-based Shaping Type is supported."
+ ::= { f3NetFlowPointEntry 9 }
+
+f3NetFlowPointIngressVlanMemberList OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..512))
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "It allows specification of VLAN members of the Flow Point.
+ VLAN members are comma separated, of the form X-Y where X is the
+ VLAN Id and Y is the VLAN Priority. VLAN members can be of
+ the form X-* or X (vlan X with all priorities), *-Y (all vlans
+ with priority Y), and X1:X2 (range of vlans from X1 to X2,
+ all priorities). Members with specific VLAN Id and specific
+ VLAN Priority are not supported. Once the Flow Point is created,
+ this attribute can only be updated using f3NetFlowPointVlanMemberAction
+ and f3NetFlowPointVlanMemberActionVlan objects."
+ ::= { f3NetFlowPointEntry 10 }
+
+f3NetFlowPointVlanMemberAction OBJECT-TYPE
+ SYNTAX FlowVlanActionType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object allows to add or remove the VLAN members specified by
+ f3NetFlowPointVlanMemberActionVlan object. SNMP manager must first
+ configure the VLAN member to be added/removed in the object
+ f3NetFlowPointVlanMemberActionVlan and then should specify
+ f3NetFlowPointVlanMemberAction on whether to add/remove the specified
+ VLAN member."
+ ::= { f3NetFlowPointEntry 11 }
+
+f3NetFlowPointVlanMemberActionVlan OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..16))
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object allows adding/removing VLAN members to a Flow Point.
+ VLAN member is of the form X-Y where X is the VLAN Id and Y is
+ the VLAN Priority. VLAN members can be of the form X-* (vlan X
+ with all priorities), *-Y (all vlans with priority Y), and X1:X2
+ (range of vlans from X1 to X2, all priorities). Members with
+ specific VLAN Id and specific VLAN Priority are not supported.
+ In order to add/remove VLAN member to a flow, user must specify
+ this object with appropriate VLAN and then
+ invoke f3NetFlowPointVlanMemberAction."
+ ::= { f3NetFlowPointEntry 12 }
+
+f3NetFlowPointIngressUntaggedFrameEnabled OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object allows to specify whether or not the Flow Point
+ supports untagged frame."
+ ::= { f3NetFlowPointEntry 13 }
+
+f3NetFlowPointCTagControl OBJECT-TYPE
+ SYNTAX FlowTagControl
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object allows specification of the tag management
+ operation on the C-TAG. Supported types are 'push', 'pushvid',
+ 'swaptag', 'swapvid' and 'none'. If the type is 'push',
+ the VLAN Id (f3NetFlowPointCTagVlanId) and priority
+ (f3NetFlowPointCTagVlanPriority) are pushed onto the frame;
+ if the type is 'pushvid', only the VLAN Id (12 bits) is pushed,
+ the Priority is copied from incoming tag's priority;
+ if the type is 'swaptag', both VLAN Id and Priority (15 bits)
+ are swapped with the specified f3NetFlowPointCTagVlanId and
+ f3NetFlowPointCTagVlanPriority;
+ if the type is 'swapvid', only the VLAN Id (12 bits) are
+ swapped with the specified f3NetFlowPointCTagVlanId;
+ if the type is 'none', no C-TAG management is performed."
+ ::= { f3NetFlowPointEntry 14 }
+
+f3NetFlowPointCTagVlanId OBJECT-TYPE
+ SYNTAX VlanId
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object allows specification of the VLAN Id to
+ be pushed or swapped, based on the value of
+ f3NetFlowPointIngressCTagControl. It is applicable
+ for 'push', 'swaptag', 'swapvid' and 'pushvid' control types."
+ ::= { f3NetFlowPointEntry 15 }
+
+f3NetFlowPointCTagVlanPriority OBJECT-TYPE
+ SYNTAX VlanPriority
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object allows specification of the VLAN Priority to
+ be pushed or swapped, based on the value of f3NetFlowPointIngressCTagControl.
+ It is applicable for 'push' and 'swaptag' control types."
+ ::= { f3NetFlowPointEntry 16 }
+
+f3NetFlowPointSTagControl OBJECT-TYPE
+ SYNTAX FlowTagControl
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object allows specification of the tag management
+ operation on the S-TAG. Supported types are 'push', 'pushvid',
+ 'swaptag', 'swapvid' and 'none'. If the type is 'push',
+ the VLAN Id (f3NetFlowPointSTagVlanId) and priority
+ (f3NetFlowPointSTagVlanPriority) are pushed onto the frame;
+ if the type is 'pushvid', only the VLAN Id (12 bits) is pushed,
+ the Priority is copied from incoming tag's priority;
+ if the type is 'swaptag', both VLAN Id and Priority (15 bits)
+ are swapped with the specified f3NetFlowPointSTagVlanId and
+ f3NetFlowPointSTagVlanPriority;
+ if the type is 'swapvid', only the VLAN Id (12 bits) are
+ swapped with the specified f3NetFlowPointSTagVlanId;
+ if the type is 'none', no S-TAG management is performed."
+ ::= { f3NetFlowPointEntry 17 }
+
+f3NetFlowPointSTagVlanId OBJECT-TYPE
+ SYNTAX VlanId
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object allows specification of the VLAN Id to
+ be pushed or swapped, based on the value of
+ f3NetFlowPointIngressSTagControl. It is applicable
+ for 'push', 'swaptag', 'swapvid' and 'pushvid' control types."
+ ::= { f3NetFlowPointEntry 18 }
+
+f3NetFlowPointSTagVlanPriority OBJECT-TYPE
+ SYNTAX VlanPriority
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object allows specification of the VLAN Priority to
+ be pushed or swapped, based on the value of
+ f3NetFlowPointIngressSTagControl. It is applicable
+ for 'push' and 'swaptag' control types."
+ ::= { f3NetFlowPointEntry 19 }
+
+f3NetFlowPointEgressOuterTagPrioMapEnabled OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object defines whether to use the Egress Prio
+ Mapping to swap the priority of outer tag. When Enabled,
+ it indicates that the operation specified in the
+ EgressPrioMapTable would be applied to Flow for specified COS.
+ When Disabled,the EgressPrioMapTable operations are ignored
+ for specified Flow COS."
+ ::= { f3NetFlowPointEntry 20 }
+
+f3NetFlowPointEgressInnerTagPrioMapEnabled OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object defines whether to use the Egress Prio
+ Mapping to swap the priority of inner tag. When Enabled,
+ it indicates that the operation specified in the
+ EgressPrioMapTable would be applied to Flow for specified COS.
+ When Disabled, the EgressPrioMapTable operations are ignored
+ for specified Flow COS."
+ ::= { f3NetFlowPointEntry 21 }
+
+f3NetFlowPointSESFramesLossThresholdRatio OBJECT-TYPE
+ SYNTAX Integer32 (0..100)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object is used to specify the frame-loss ratio
+ per flow that starts counting Severely Errored Seconds (SES)
+ on the flowpoint.
+ This functionality is applicable if the flowpoint is monitored
+ using the Y.1731 ESA functionality."
+ ::= { f3NetFlowPointEntry 22 }
+
+f3NetFlowPointDefaultMemberEnabled OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Truth Value means that on this FP, the membership is all the tag
+ packets without match any other membership associated to the port.
+ Untagged means untagged flow. Default only care tagged flow."
+ ::= { f3NetFlowPointEntry 23 }
+
+f3NetFlowPointMcastRateLimitEnabled OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Whether multicast packets need be limited per FP."
+ ::= { f3NetFlowPointEntry 24 }
+
+f3NetFlowPointMcastRateLimitSpeedLo OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The rate limiting for multicast packets per FP. When
+ f3NetFlowPointMcastRateLimitEnabled and the value is 0,
+ it means all multicast frame are dropped. This objects
+ only represents low 32 bits."
+ ::= { f3NetFlowPointEntry 25 }
+
+f3NetFlowPointMcastRateLimitSpeedHi OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The rate limiting for multicast packets per FP. When
+ f3NetFlowPointMcastRateLimitEnabled and the value is 0,
+ it means all multicast frame are dropped. This objects
+ only represents high 32 bits."
+ ::= { f3NetFlowPointEntry 26 }
+
+f3NetFlowPointBcastRateLimitEnabled OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Whether broadcast packets need be limited per FP."
+ ::= { f3NetFlowPointEntry 27 }
+
+f3NetFlowPointBcastRateLimitSpeedLo OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The rate limiting for broadcast packets per FP. When
+ f3NetFlowPointBcastRateLimitEnabled and the value is 0,
+ it means all multicast frame are dropped. This objects
+ only represents low 32 bits."
+ ::= { f3NetFlowPointEntry 28 }
+
+f3NetFlowPointBcastRateLimitSpeedHi OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The rate limiting for broadcast packets per FP. When
+ f3NetFlowPointBcastRateLimitEnabled and the value is 0,
+ it means all multicast frame are dropped. This objects
+ only represents high 32 bits."
+ ::= { f3NetFlowPointEntry 29 }
+
+f3NetFlowPointCombinedRateLimitEnabled OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Whether broadcast and multicast packets need be limited per FP."
+ ::= { f3NetFlowPointEntry 30 }
+
+f3NetFlowPointCombinedRateLimitSpeedLo OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The rate limiting for broadcast and multicast packets per FP.
+ When f3NetFlowPointCombinedRateLimitEnabled is true and the value is 0,
+ it means all broadcast and multicast frame are dropped. This object
+ only represents low 32 bits."
+ ::= { f3NetFlowPointEntry 31 }
+
+f3NetFlowPointCombinedRateLimitSpeedHi OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The rate limiting for broadcast and multicast packets per FP.
+ When f3NetFlowPointCombinedRateLimitEnabled is true and the value is 0,
+ it means all broadcast and multicast frame are dropped. This object
+ only represents high 32 bits."
+ ::= { f3NetFlowPointEntry 32 }
+
+f3NetFlowPointSplitHorizonGroupOID OBJECT-TYPE
+ SYNTAX VariablePointer
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Specifies the Split-Horizon Group OID. If there is no SHG, the value is none."
+ ::= { f3NetFlowPointEntry 33 }
+
+f3NetFlowPointLoopAvoidance OBJECT-TYPE
+ SYNTAX VariablePointer
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "EID of this associated Loop Avoidance protocol entity.
+ A value of NONE indicates there is no loop avoidance protocol.
+ Currently ERP EID is filled when ELAN service is created."
+ ::= { f3NetFlowPointEntry 34 }
+
+f3NetFlowPointHierarchicalCOSEnabled OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Enable or Disable Hierarchical COS shaping (flow shaping)."
+ ::= { f3NetFlowPointEntry 35 }
+
+f3NetFlowPointMaximumBWLo OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This attribute description the Flow Point maximum bandwidth.
+ This object only represents low 32 bits."
+ ::= { f3NetFlowPointEntry 36 }
+
+f3NetFlowPointMaximumBWHi OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This attribute description the Flow Point maximum bandwidth.
+ This object only represents high 32 bits."
+ ::= { f3NetFlowPointEntry 37 }
+
+f3NetFlowPointGuaranteedBWLo OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This attribute description the Flow Point guaranteed bandwidth.
+ This object only represents low 32 bits."
+ ::= { f3NetFlowPointEntry 38 }
+
+f3NetFlowPointGuaranteedBWHi OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This attribute description the Flow Point guaranteed bandwidth.
+ This objects only represents high 32 bits."
+ ::= { f3NetFlowPointEntry 39 }
+
+f3NetFlowPointAutoBandwidthConfigEnabled OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object specifies the shaper bandwidth is automatically adjusted
+ by the system. For a single COS Flow Point, the shaper EIR bandwidth is
+ set to the maximum port bandwidth; the shaper CIR is set to the available
+ port bandwidth multiplied by the value of the f3NetFlowPointAutoCIRPercentage
+ object. For a Hierarchical-COS Flow Point, the f3NetFlowPointMaximumBWLo and
+ f3NetFlowPointMaximumBWHi are set to the maximum port bandwidth;
+ the f3NetFlowPointGuaranteedBWLo and f3NetFlowPointGuaranteedBWHi are set to
+ the available port bandwidth multiplied by the value of the
+ f3NetFlowPointAutoCIRPercentage object. The value of this object must be FALSE
+ when f3NetFlowPointIngressMultiCOSEnabled is TRUE and
+ f3NetFlowPointHierarchicalCOSEnabled is FALSE."
+ ::= { f3NetFlowPointEntry 40 }
+
+f3NetFlowPointAutoCIRPercentage OBJECT-TYPE
+ SYNTAX Integer32 (0..100)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object specifies the percentage of available shaper CIR to be assigned
+ to this Flow Point when f3NetFlowPointAutoBandwidthConfigEnabled is TRUE."
+ ::= { f3NetFlowPointEntry 41 }
+
+f3NetFlowPointFrameFwdEnabled OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "When enabled Flow Point will forward frames it receives.
+ When disabled, the Flow Point will not forward frames it receives."
+ ::= { f3NetFlowPointEntry 42 }
+
+f3NetFlowPointStorageType OBJECT-TYPE
+ SYNTAX StorageType
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The type of storage configured for this entry."
+ ::= { f3NetFlowPointEntry 43 }
+
+f3NetFlowPointRowStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The status of this row.
+ An entry MUST NOT exist in the active state unless all
+ objects in the entry have an appropriate value, as described
+ in the description clause for each writable object.
+
+ The values of f3NetFlowPointRowStatus supported are
+ createAndGo(4) and destroy(6). All mandatory attributes
+ must be specified in a single SNMP SET request with
+ f3NetFlowPointRowStatus value as createAndGo(4).
+ Upon successful row creation, this object has a
+ value of active(1).
+
+ The f3NetFlowPointRowStatus object may be modified if
+ the associated instance of this object is equal to active(1)."
+ ::= { f3NetFlowPointEntry 44 }
+
+f3NetFlowPointUsePortPrioMapProfile OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This indicates whether the flow point is using, if true, the port's
+ Priority Mapping Profile or, if false, is using its own
+ Priority Mapping Profile."
+ ::= { f3NetFlowPointEntry 45 }
+
+f3NetFlowPointRefPrioMapProfile OBJECT-TYPE
+ SYNTAX VariablePointer
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object allows to set priority map profile."
+ ::= { f3NetFlowPointEntry 46 }
+
+f3NetFlowpointRefConnectGuardFlowObject OBJECT-TYPE
+ SYNTAX VariablePointer
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object specifies Mac Sec flow object OID."
+ ::= { f3NetFlowPointEntry 47 }
+
+f3NetFlowpointSecureBlockingControl OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object can be used to enable/disable secure block."
+ ::= { f3NetFlowPointEntry 48 }
+
+f3NetFlowpointSecureState OBJECT-TYPE
+ SYNTAX FlowSecState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object specifies the secure state of this flow."
+ ::= { f3NetFlowPointEntry 49 }
+
+--
+-- Net Flow Point QoS Shaper
+--
+
+f3NetFpQosShaperTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF F3NetFpQosShaperEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of entries corresponding to Net Flow Point
+ Quality of Service Shaper for configuration purposes."
+ ::= { f3FpmConfigObjects 8 }
+
+f3NetFpQosShaperEntry OBJECT-TYPE
+ SYNTAX F3NetFpQosShaperEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A conceptual row in the f3NetFpQosShaperTable.
+ These entries represent an Net Flow Point Quality
+ of Service Shaper."
+ INDEX { neIndex, shelfIndex, slotIndex, cmEthernetNetPortIndex,
+ f3NetFlowPointIndex, f3NetFpQosShaperIndex }
+ ::= { f3NetFpQosShaperTable 1 }
+
+F3NetFpQosShaperEntry ::= SEQUENCE {
+ f3NetFpQosShaperIndex Integer32,
+
+ f3NetFpQosShaperAdminState AdminState,
+ f3NetFpQosShaperOperationalState OperationalState,
+ f3NetFpQosShaperSecondaryState SecondaryState,
+
+ f3NetFpQosShaperCIRLo Unsigned32,
+ f3NetFpQosShaperCIRHi Unsigned32,
+ f3NetFpQosShaperEIRLo Unsigned32,
+ f3NetFpQosShaperEIRHi Unsigned32,
+ f3NetFpQosShaperCBS Unsigned32,
+ f3NetFpQosShaperEBS Unsigned32,
+ f3NetFpQosShaperBufferSize Unsigned32,
+ f3NetFpQosShaperCOS Integer32,
+
+ f3NetFpQosShaperStorageType StorageType,
+ f3NetFpQosShaperRowStatus RowStatus
+}
+
+f3NetFpQosShaperIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..8)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The unique integer index value corresponding to a Quality
+ of Service Shaper."
+ ::= { f3NetFpQosShaperEntry 1 }
+
+f3NetFpQosShaperAdminState OBJECT-TYPE
+ SYNTAX AdminState
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object represents the Administrative State of a Shaper."
+ ::= { f3NetFpQosShaperEntry 2 }
+
+f3NetFpQosShaperOperationalState OBJECT-TYPE
+ SYNTAX OperationalState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object represents the Operational State of a Shaper."
+ ::= { f3NetFpQosShaperEntry 3 }
+
+f3NetFpQosShaperSecondaryState OBJECT-TYPE
+ SYNTAX SecondaryState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object represents the Secondary State of the Shaper."
+ ::= { f3NetFpQosShaperEntry 4 }
+
+f3NetFpQosShaperCIRLo OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object represents the Commited Information Rate (CIR)
+ (Lower 32 bits) of the Shaper."
+ ::= { f3NetFpQosShaperEntry 5 }
+
+f3NetFpQosShaperCIRHi OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object represents the Commited Information Rate (CIR)
+ (Higher 32 bits) of the Shaper."
+ ::= { f3NetFpQosShaperEntry 6 }
+
+f3NetFpQosShaperEIRLo OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object represents the Excess Information Rate (EIR)
+ (Lower 32 bits) of a Shaper."
+ ::= { f3NetFpQosShaperEntry 7 }
+
+f3NetFpQosShaperEIRHi OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object represents the Excess Information Rate (EIR)
+ (Lower 32 bits) of a Shaper."
+ ::= { f3NetFpQosShaperEntry 8 }
+
+f3NetFpQosShaperCBS OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object represents the Commited Burst Size (CBS)
+ of a Shaper."
+ ::= { f3NetFpQosShaperEntry 9 }
+
+f3NetFpQosShaperEBS OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object represents the Excess Burst Size (EBS)
+ of a Shaper."
+ ::= { f3NetFpQosShaperEntry 10 }
+
+f3NetFpQosShaperBufferSize OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object represents the Buffer Size of the Shaper."
+ ::= { f3NetFpQosShaperEntry 11 }
+
+f3NetFpQosShaperCOS OBJECT-TYPE
+ SYNTAX Integer32 (0..7)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object provides the COS (Class of Service) value for
+ the QOS Shaper."
+ ::= { f3NetFpQosShaperEntry 12 }
+
+f3NetFpQosShaperStorageType OBJECT-TYPE
+ SYNTAX StorageType
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The type of storage configured for this entry."
+ ::= { f3NetFpQosShaperEntry 13 }
+
+f3NetFpQosShaperRowStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The status of this row.
+ An entry MUST NOT exist in the active state unless all
+ objects in the entry have an appropriate value, as described
+ in the description clause for each writable object.
+
+ The values of f3NetFpQosShaperRowStatus supported are
+ createAndGo(4) and destroy(6). All mandatory attributes
+ must be specified in a single SNMP SET request with
+ f3NetFpQosShaperRowStatus value as createAndGo(4).
+ Upon successful row creation, this object has a
+ value of active(1).
+
+ The f3NetFpQosShaperRowStatus object may be modified if
+ the associated instance of this object is equal to active(1)."
+ ::= { f3NetFpQosShaperEntry 14 }
+
+--
+-- Net Flow Point QoS Policer
+--
+
+f3NetFpQosPolicerTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF F3NetFpQosPolicerEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of entries corresponding to Net Flow Point
+ Quality of Service Policer for configuration purposes."
+ ::= { f3FpmConfigObjects 9 }
+
+f3NetFpQosPolicerEntry OBJECT-TYPE
+ SYNTAX F3NetFpQosPolicerEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A conceptual row in the f3NetFpQosPolicerTable.
+ These entries represent an Net Flow Point Quality
+ of Service Policer."
+ INDEX { neIndex, shelfIndex, slotIndex, cmEthernetNetPortIndex,
+ f3NetFlowPointIndex, f3NetFpQosPolicerIndex }
+ ::= { f3NetFpQosPolicerTable 1 }
+
+F3NetFpQosPolicerEntry ::= SEQUENCE {
+ f3NetFpQosPolicerIndex Integer32,
+
+ f3NetFpQosPolicerAdminState AdminState,
+ f3NetFpQosPolicerOperationalState OperationalState,
+ f3NetFpQosPolicerSecondaryState SecondaryState,
+
+ f3NetFpQosPolicerCIRLo Unsigned32,
+ f3NetFpQosPolicerCIRHi Unsigned32,
+ f3NetFpQosPolicerEIRLo Unsigned32,
+ f3NetFpQosPolicerEIRHi Unsigned32,
+ f3NetFpQosPolicerCBS Integer32,
+ f3NetFpQosPolicerEBS Integer32,
+
+ f3NetFpQosPolicerAlgorithm PolicerAlgorithmType,
+ f3NetFpQosPolicerColorMode PolicerColorMode,
+ f3NetFpQosPolicerCouplingFlag TruthValue,
+ f3NetFpQosPolicerPolicingEnabled TruthValue,
+
+ f3NetFpQosPolicerStorageType StorageType,
+ f3NetFpQosPolicerRowStatus RowStatus
+}
+
+f3NetFpQosPolicerIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..8)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The unique integer index value corresponding to a Quality
+ of Service Policer.
+ The Policer Index represents the COS level. This
+ is applicable in case of a Multi COS Flow Point. Index 1
+ represents COS 0; Index 2 represents COS 1 and so on."
+ ::= { f3NetFpQosPolicerEntry 1 }
+
+f3NetFpQosPolicerAdminState OBJECT-TYPE
+ SYNTAX AdminState
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object represents the Administrative State of a Policer."
+ ::= { f3NetFpQosPolicerEntry 2 }
+
+f3NetFpQosPolicerOperationalState OBJECT-TYPE
+ SYNTAX OperationalState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object represents the Operational State of a Policer."
+ ::= { f3NetFpQosPolicerEntry 3 }
+
+f3NetFpQosPolicerSecondaryState OBJECT-TYPE
+ SYNTAX SecondaryState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object represents the Secondary State of a Policer."
+ ::= { f3NetFpQosPolicerEntry 4 }
+
+f3NetFpQosPolicerCIRLo OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object represents the Commited Information Rate (CIR)
+ (Lower 32 bits) of the Policer."
+ ::= { f3NetFpQosPolicerEntry 5 }
+
+f3NetFpQosPolicerCIRHi OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object represents the Commited Information Rate (CIR)
+ (Higher 32 bits) of the Policer."
+ ::= { f3NetFpQosPolicerEntry 6 }
+
+f3NetFpQosPolicerEIRLo OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object represents the Excess Information Rate (EIR)
+ (Lower 32 bits) of a Policer."
+ ::= { f3NetFpQosPolicerEntry 7 }
+
+f3NetFpQosPolicerEIRHi OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object represents the Excess Information Rate (EIR)
+ (Lower 32 bits) of a Policer."
+ ::= { f3NetFpQosPolicerEntry 8 }
+
+f3NetFpQosPolicerCBS OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object represents the Commited Burst Size (CBS)
+ of a Policer."
+ ::= { f3NetFpQosPolicerEntry 9 }
+
+f3NetFpQosPolicerEBS OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object represents the Excess Burst Size (EBS)
+ of a Policer."
+ ::= { f3NetFpQosPolicerEntry 10 }
+
+f3NetFpQosPolicerAlgorithm OBJECT-TYPE
+ SYNTAX PolicerAlgorithmType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object represents Policer algorithm as 'srTCM'
+ (Single Rate Triple Color Marking) or 'trTCM'
+ (Two Rate Triple Color Marking)."
+ ::= { f3NetFpQosPolicerEntry 11 }
+
+f3NetFpQosPolicerColorMode OBJECT-TYPE
+ SYNTAX PolicerColorMode
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object allows specification of Policer Color Mode as
+ 'color-aware' or 'color-blind'."
+ ::= { f3NetFpQosPolicerEntry 12 }
+
+f3NetFpQosPolicerCouplingFlag OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object allows specification of Policer Coupling Flag.
+ When coupling is enabled, tokens that would normally be
+ added to the C-bucket are passed to the E-bucket only once the CIR
+ bucket has reached its CBS level. Therefore under this condition
+ the E-bucket is being filled at the rate of CIR + EIR.
+ Normally the long term average of frames declared yellow is
+ bounded by the EIR. Coupling is a function to allow the
+ long term average of frames declared yellow to be bounded by
+ CIR + EIR. This allows a higher volume of yellow frames
+ to be delivered/received if the arrival of green marked frames
+ is low. Tokens from the E-bucket do NOT get passed to the
+ C-bucket once the EBS level has been reached.
+ Enabling coupling in combination with a provisioned EIR of 0
+ allows for a single rate three color marking (srTCM) algorithm
+ to be established. In this situation the E-bucket is filled at the
+ CIR rate in the case the C-bucket is filled to its CBS level."
+ ::= { f3NetFpQosPolicerEntry 13 }
+
+f3NetFpQosPolicerPolicingEnabled OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object allows specification of Policer Policing.
+ When Policing is disabled, traffic policing is bypassed.
+ When Policing is enabled, traffic policing is applied."
+ ::= { f3NetFpQosPolicerEntry 14 }
+
+f3NetFpQosPolicerStorageType OBJECT-TYPE
+ SYNTAX StorageType
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The type of storage configured for this entry."
+ ::= { f3NetFpQosPolicerEntry 15 }
+
+f3NetFpQosPolicerRowStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The status of this row.
+ An entry MUST NOT exist in the active state unless all
+ objects in the entry have an appropriate value, as described
+ in the description clause for each writable object.
+
+ The values of f3NetFpQosPolicerRowStatus supported are
+ createAndGo(4) and destroy(6). All mandatory attributes
+ must be specified in a single SNMP SET request with
+ f3NetFpQosPolicerRowStatus value as createAndGo(4).
+ Upon successful row creation, this object has a
+ value of active(1).
+
+ The f3NetFpQosPolicerRowStatus object may be modified if
+ the associated instance of this object is equal to active(1)."
+ ::= { f3NetFpQosPolicerEntry 16 }
+
+--
+-- Net Flow Point Control Protocol Disposition
+--
+
+f3NetFlowPointCpdV2Table OBJECT-TYPE
+ SYNTAX SEQUENCE OF F3NetFlowPointCpdV2Entry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of entries corresponding to Net Flow Point
+ Control Protocol Disposition V2."
+ ::= { f3FpmConfigObjects 10 }
+
+f3NetFlowPointCpdV2Entry OBJECT-TYPE
+ SYNTAX F3NetFlowPointCpdV2Entry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A conceptual row in the f3NetFlowPointCpdV2Table.
+ These entries represent a Control Protocol Disposition
+ filtering criteria on the Net Flow Point."
+ INDEX { neIndex, shelfIndex, slotIndex, cmEthernetNetPortIndex,
+ f3NetFlowPointIndex, f3NetFlowPointCpdV2Index }
+ ::= { f3NetFlowPointCpdV2Table 1 }
+
+F3NetFlowPointCpdV2Entry ::= SEQUENCE {
+ f3NetFlowPointCpdV2Index Integer32,
+ f3NetFlowPointCpdV2IslDispType CmControlProtocolDispType,
+ f3NetFlowPointCpdV2PagpDispType CmControlProtocolDispType,
+ f3NetFlowPointCpdV2UdldDispType CmControlProtocolDispType,
+ f3NetFlowPointCpdV2CdpDispType CmControlProtocolDispType,
+ f3NetFlowPointCpdV2VtpDispType CmControlProtocolDispType,
+ f3NetFlowPointCpdV2DtpDispType CmControlProtocolDispType,
+ f3NetFlowPointCpdV2PvstpPlusDispType CmControlProtocolDispType,
+ f3NetFlowPointCpdV2UplinkFastDispType CmControlProtocolDispType,
+ f3NetFlowPointCpdV2VlanBridgeDispType CmControlProtocolDispType,
+ f3NetFlowPointCpdV2L2PTDispType CmControlProtocolDispType,
+ f3NetFlowPointCpdV2BPDUDispType CmControlProtocolDispType,
+ f3NetFlowPointCpdV2PauseDispType CmControlProtocolDispType,
+ f3NetFlowPointCpdV2LACPDispType CmControlProtocolDispType,
+ f3NetFlowPointCpdV2LACPMarkerDispType CmControlProtocolDispType,
+ f3NetFlowPointCpdV2EfmOamDispType CmControlProtocolDispType,
+ f3NetFlowPointCpdV2SSMDispType CmControlProtocolDispType,
+ f3NetFlowPointCpdV2PortAuthenDispType CmControlProtocolDispType,
+ f3NetFlowPointCpdV2LANBridgesDispType CmControlProtocolDispType,
+ f3NetFlowPointCpdV2GMRPDispType CmControlProtocolDispType,
+ f3NetFlowPointCpdV2GVRPDispType CmControlProtocolDispType,
+ f3NetFlowPointCpdV2GARPDispType CmControlProtocolDispType,
+ f3NetFlowPointCpdV2ActiveControlProtocols CmActiveControlProtocolsType,
+ f3NetFlowPointCpdV2ELMIDispType CmControlProtocolDispType,
+ f3NetFlowPointCpdV2Mac00DispType CmControlProtocolDispType,
+ f3NetFlowPointCpdV2Mac01DispType CmControlProtocolDispType,
+ f3NetFlowPointCpdV2Mac02DispType CmControlProtocolDispType,
+ f3NetFlowPointCpdV2Mac03DispType CmControlProtocolDispType,
+ f3NetFlowPointCpdV2Mac04DispType CmControlProtocolDispType,
+ f3NetFlowPointCpdV2Mac05DispType CmControlProtocolDispType,
+ f3NetFlowPointCpdV2Mac06DispType CmControlProtocolDispType,
+ f3NetFlowPointCpdV2Mac07DispType CmControlProtocolDispType,
+ f3NetFlowPointCpdV2Mac08DispType CmControlProtocolDispType,
+ f3NetFlowPointCpdV2Mac09DispType CmControlProtocolDispType,
+ f3NetFlowPointCpdV2Mac0ADispType CmControlProtocolDispType,
+ f3NetFlowPointCpdV2Mac0BDispType CmControlProtocolDispType,
+ f3NetFlowPointCpdV2Mac0CDispType CmControlProtocolDispType,
+ f3NetFlowPointCpdV2Mac0DDispType CmControlProtocolDispType,
+ f3NetFlowPointCpdV2Mac0EDispType CmControlProtocolDispType,
+ f3NetFlowPointCpdV2Mac0FDispType CmControlProtocolDispType,
+ f3NetFlowPointCpdV2NearestLLDPDispType CmControlProtocolDispType,
+ f3NetFlowPointCpdV2NonTpmrLLDPDispType CmControlProtocolDispType,
+ f3NetFlowPointCpdV2CustomerLLDPDispType CmControlProtocolDispType
+}
+
+f3NetFlowPointCpdV2Index OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Unique Index value to access the CPD row."
+ ::= { f3NetFlowPointCpdV2Entry 1 }
+
+f3NetFlowPointCpdV2IslDispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Control Protocol Disposition for ISL (Inter Switch Link).
+ MAC Address (01:00:0C:00:00:00)."
+ ::= { f3NetFlowPointCpdV2Entry 2 }
+
+f3NetFlowPointCpdV2PagpDispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Control Protocol Disposition for PAGP (Port Aggregation Protocol).
+ MAC Address (01:00:0C:CC:CC:CC), Ethertype(0x104)."
+ ::= { f3NetFlowPointCpdV2Entry 3 }
+
+f3NetFlowPointCpdV2UdldDispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Control Protocol Disposition for UDLD (Unidirectional Link Detection).
+ MAC Address (01:00:0C:CC:CC:CC), Ethertype(0x111)."
+ ::= { f3NetFlowPointCpdV2Entry 4 }
+
+f3NetFlowPointCpdV2CdpDispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Control Protocol Disposition for CDP (Cisco Discovery Protocol).
+ MAC Address (01:00:0C:CC:CC:CC), Ethertype(0x2000)."
+ ::= { f3NetFlowPointCpdV2Entry 5 }
+
+f3NetFlowPointCpdV2VtpDispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Control Protocol Disposition for VTP (VLAN Trunking Protocol).
+ MAC Address (01:00:0C:CC:CC:CC), Ethertype(0x2003)."
+ ::= { f3NetFlowPointCpdV2Entry 6 }
+
+f3NetFlowPointCpdV2DtpDispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Control Protocol Disposition for DTP (Dynamic Trunking).
+ MAC Address (01:00:0C:CC:CC:CC), Ethertype(0x2004)."
+ ::= { f3NetFlowPointCpdV2Entry 7 }
+
+f3NetFlowPointCpdV2PvstpPlusDispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Control Protocol Disposition for Spanning Tree PVSTP+.
+ MAC Address (01:00:0C:CC:CC:CC), Ethertype(0x10B)."
+ ::= { f3NetFlowPointCpdV2Entry 8 }
+
+f3NetFlowPointCpdV2UplinkFastDispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Control Protocol Disposition for STP UplinkFast.
+ MAC Address (01:00:0C:CD:CD:CD), Ethertype(0x200A)."
+ ::= { f3NetFlowPointCpdV2Entry 9 }
+
+f3NetFlowPointCpdV2VlanBridgeDispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Control Protocol Disposition for VLAN Bridge.
+ MAC Address (01:00:0C:CD:CD:CE), Ethertype(0x10C)."
+ ::= { f3NetFlowPointCpdV2Entry 10 }
+
+f3NetFlowPointCpdV2L2PTDispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Control Protocol Disposition for Layer 2 Protocol Tunnelling(L2PT).
+ MAC Address (01:00:0C:CD:CD:D0)."
+ ::= { f3NetFlowPointCpdV2Entry 11 }
+
+f3NetFlowPointCpdV2BPDUDispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Control Protocol Disposition for IEEE Spanning Tree(STP),
+ MSTP (Multiple Spanning Tree) and RSTP (Rapid Reconfiguration of
+ Spanning Tree). MAC Address (01:80:C2:00:00:00)."
+ ::= { f3NetFlowPointCpdV2Entry 12 }
+
+f3NetFlowPointCpdV2PauseDispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Control Protocol Disposition for IEEE 802.3x Flow Control
+ (PAUSE frames)."
+ ::= { f3NetFlowPointCpdV2Entry 13 }
+
+f3NetFlowPointCpdV2LACPDispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Control Protocol Disposition for 802.3ad Link Aggregation
+ Protocol.
+ MAC Address (01:80:C2:00:00:03), Ethertype (0x8809), Subtype(01)."
+ ::= { f3NetFlowPointCpdV2Entry 14 }
+
+f3NetFlowPointCpdV2LACPMarkerDispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Control Protocol Disposition for IEEE 802.3ad Marker Protocol.
+ MAC Address (01:80:C2:00:00:03), Ethertype (0x8809), Subtype(02)."
+ ::= { f3NetFlowPointCpdV2Entry 15 }
+
+f3NetFlowPointCpdV2EfmOamDispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Control Protocol Disposition for IEEE 802.3ah EFM OAM.
+ MAC Address (01:80:C2:00:00:03), Ethertype (0x8809), Subtype(03)."
+ ::= { f3NetFlowPointCpdV2Entry 16 }
+
+f3NetFlowPointCpdV2SSMDispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Control Protocol Disposition for Sync Status Messages.
+ MAC Address (01:80:C2:00:00:02), Ethertype (0x19A7), Subtype(0A)."
+ ::= { f3NetFlowPointCpdV2Entry 17 }
+
+f3NetFlowPointCpdV2PortAuthenDispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Control Protocol Disposition for IEEE 802.1x Protocol.
+ MAC Address (01:80:C2:00:00:03), Ethertype (0x888E)."
+ ::= { f3NetFlowPointCpdV2Entry 18 }
+
+f3NetFlowPointCpdV2LANBridgesDispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Control Protocol Disposition for IEEE 802.1d LAN Bridge Managment.
+ MAC Address (01:80:C2:00:00:10)."
+ ::= { f3NetFlowPointCpdV2Entry 19 }
+
+f3NetFlowPointCpdV2GMRPDispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Control Protocol Disposition for GARP Multicast Registration
+ Protocol. MAC Address (01:80:C2:00:00:20)."
+ ::= { f3NetFlowPointCpdV2Entry 20 }
+
+f3NetFlowPointCpdV2GVRPDispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Control Protocol Disposition for GARP VLAN Registration
+ Protocol. MAC Address (01:80:C2:00:00:21)."
+ ::= { f3NetFlowPointCpdV2Entry 21 }
+
+f3NetFlowPointCpdV2GARPDispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Group Disposition type which includes GARP Reserved
+ MAC Address from range 01:80:C2:00:00:22 to 01:80:C2:00:00:2F."
+ ::= { f3NetFlowPointCpdV2Entry 22 }
+
+f3NetFlowPointCpdV2ActiveControlProtocols OBJECT-TYPE
+ SYNTAX CmActiveControlProtocolsType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "List of Active Control Protocol Dispositions. Note that
+ if the Port Level Disposition control is set to PEER or
+ DISCARD, the flow level disposition is no longer active.
+ This object provides information on all the active
+ dispositions."
+ ::= { f3NetFlowPointCpdV2Entry 23 }
+
+f3NetFlowPointCpdV2ELMIDispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ELMI (Ethernet Local Management Interface) Disposition type.
+ MAC Address 01:80:C2:00:00:07 and EtherType of 0x88EE."
+ ::= { f3NetFlowPointCpdV2Entry 24 }
+
+f3NetFlowPointCpdV2Mac00DispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "MAC Address 01:80:C2:00:00:00 Disposition type."
+ ::= { f3NetFlowPointCpdV2Entry 25 }
+
+f3NetFlowPointCpdV2Mac01DispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "MAC Address 01:80:C2:00:00:01 Disposition type."
+ ::= { f3NetFlowPointCpdV2Entry 26 }
+
+f3NetFlowPointCpdV2Mac02DispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "MAC Address 01:80:C2:00:00:02 Disposition type."
+ ::= { f3NetFlowPointCpdV2Entry 27 }
+
+f3NetFlowPointCpdV2Mac03DispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "MAC Address 01:80:C2:00:00:03 Disposition type."
+ ::= { f3NetFlowPointCpdV2Entry 28 }
+
+f3NetFlowPointCpdV2Mac04DispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "MAC Address 01:80:C2:00:00:04 Disposition type."
+ ::= { f3NetFlowPointCpdV2Entry 29 }
+
+f3NetFlowPointCpdV2Mac05DispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "MAC Address 01:80:C2:00:00:05 Disposition type."
+ ::= { f3NetFlowPointCpdV2Entry 30 }
+
+f3NetFlowPointCpdV2Mac06DispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "MAC Address 01:80:C2:00:00:06 Disposition type."
+ ::= { f3NetFlowPointCpdV2Entry 31 }
+
+f3NetFlowPointCpdV2Mac07DispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "MAC Address 01:80:C2:00:00:07 Disposition type."
+ ::= { f3NetFlowPointCpdV2Entry 32 }
+
+f3NetFlowPointCpdV2Mac08DispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "MAC Address 01:80:C2:00:00:08 Disposition type."
+ ::= { f3NetFlowPointCpdV2Entry 33 }
+
+f3NetFlowPointCpdV2Mac09DispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "MAC Address 01:80:C2:00:00:09 Disposition type."
+ ::= { f3NetFlowPointCpdV2Entry 34 }
+
+f3NetFlowPointCpdV2Mac0ADispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "MAC Address 01:80:C2:00:00:0A Disposition type."
+ ::= { f3NetFlowPointCpdV2Entry 35 }
+
+f3NetFlowPointCpdV2Mac0BDispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "MAC Address 01:80:C2:00:00:0B Disposition type."
+ ::= { f3NetFlowPointCpdV2Entry 36 }
+
+f3NetFlowPointCpdV2Mac0CDispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "MAC Address 01:80:C2:00:00:0C Disposition type."
+ ::= { f3NetFlowPointCpdV2Entry 37 }
+
+f3NetFlowPointCpdV2Mac0DDispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "MAC Address 01:80:C2:00:00:0D Disposition type."
+ ::= { f3NetFlowPointCpdV2Entry 38 }
+
+f3NetFlowPointCpdV2Mac0EDispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "MAC Address 01:80:C2:00:00:0E Disposition type."
+ ::= { f3NetFlowPointCpdV2Entry 39 }
+
+f3NetFlowPointCpdV2Mac0FDispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "MAC Address 01:80:C2:00:00:0F Disposition type."
+ ::= { f3NetFlowPointCpdV2Entry 40 }
+
+f3NetFlowPointCpdV2NearestLLDPDispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "LLDP (Link Layer Discovery Protocol) Nearest Bridge Disposition type."
+ ::= { f3NetFlowPointCpdV2Entry 41 }
+
+f3NetFlowPointCpdV2NonTpmrLLDPDispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "LLDP (Link Layer Discovery Protocol) Non-TPMR Bridge Disposition type."
+ ::= { f3NetFlowPointCpdV2Entry 42 }
+
+f3NetFlowPointCpdV2CustomerLLDPDispType OBJECT-TYPE
+ SYNTAX CmControlProtocolDispType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "LLDP (Link Layer Discovery Protocol) Customer Bridge Disposition type."
+ ::= { f3NetFlowPointCpdV2Entry 43 }
+
+--
+-- Net Flowpoint table extension for Learning Control configuration
+--
+f3NetFlowPointLearningConfigTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF F3NetFlowPointLearningConfigEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table extends f3NetFlowPointTable to provide parameters for MAC Table control
+ configuration."
+ ::= { f3FpmConfigObjects 11 }
+
+f3NetFlowPointLearningConfigEntry OBJECT-TYPE
+ SYNTAX F3NetFlowPointLearningConfigEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A conceptual row in the f3NetFlowPointLearningConfigTable."
+ AUGMENTS { f3NetFlowPointEntry }
+ ::= { f3NetFlowPointLearningConfigTable 1 }
+
+F3NetFlowPointLearningConfigEntry ::= SEQUENCE {
+ f3NetFlowPointLearningConfigLearningEnabled TruthValue,
+ f3NetFlowPointLearningConfigMaxFwdEntries Integer32,
+ f3NetFlowPointLearningConfigProtectLearningCtrl ProtectLearningControl,
+ f3NetFlowPointLearningConfigAction FlowLearningConfigAction
+}
+
+f3NetFlowPointLearningConfigLearningEnabled OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object allows configuring Learning Control on this Flowpoint."
+ ::= { f3NetFlowPointLearningConfigEntry 1 }
+
+f3NetFlowPointLearningConfigMaxFwdEntries OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object allows configuring the maximum number of Forwarding Entries
+ on this Flowpoint."
+ ::= { f3NetFlowPointLearningConfigEntry 2 }
+
+f3NetFlowPointLearningConfigProtectLearningCtrl OBJECT-TYPE
+ SYNTAX ProtectLearningControl
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object allows configuring Learning Control on this Flowpoint."
+ ::= { f3NetFlowPointLearningConfigEntry 3 }
+
+f3NetFlowPointLearningConfigAction OBJECT-TYPE
+ SYNTAX FlowLearningConfigAction
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This objects allows performing user action on Flow Learning Table."
+ ::= { f3NetFlowPointLearningConfigEntry 4 }
+
+--
+-- Access Flowpoint Current Statistics Table
+--
+
+f3AccFlowPointStatsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF F3AccFlowPointStatsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A collection of FlowPoint statistics.
+ These reflect the current data."
+ ::= { f3FpmPerfObjects 1 }
+
+f3AccFlowPointStatsEntry OBJECT-TYPE
+ SYNTAX F3AccFlowPointStatsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A conceptual row in the f3AccFlowPointStatsTable.
+ Entries exist in this table for each FlowPoint."
+ INDEX { neIndex, shelfIndex, slotIndex, cmEthernetAccPortIndex,
+ f3AccFlowPointIndex, f3AccFlowPointStatsIndex }
+ ::= { f3AccFlowPointStatsTable 1 }
+
+F3AccFlowPointStatsEntry ::= SEQUENCE {
+ f3AccFlowPointStatsIndex Integer32,
+ f3AccFlowPointStatsIntervalType CmPmIntervalType,
+ f3AccFlowPointStatsValid TruthValue,
+ f3AccFlowPointStatsAction CmPmBinAction,
+ f3AccFlowPointStatsL2CPFD PerfCounter64,
+ f3AccFlowPointStatsABRRx PerfCounter64,
+ f3AccFlowPointStatsABRRLRx PerfCounter64,
+ f3AccFlowPointStatsUAS PerfCounter64,
+ f3AccFlowPointStatsSES PerfCounter64,
+ f3AccFlowPointStatsFMG PerfCounter64,
+ f3AccFlowPointStatsFMY PerfCounter64,
+ f3AccFlowPointStatsFMRD PerfCounter64,
+ f3AccFlowPointStatsFTD PerfCounter64,
+ f3AccFlowPointStatsBytesIn PerfCounter64,
+ f3AccFlowPointStatsBytesOut PerfCounter64,
+ f3AccFlowPointStatsIBRMax PerfCounter64,
+ f3AccFlowPointStatsIBRRlMax PerfCounter64,
+ f3AccFlowPointStatsIBRMin PerfCounter64,
+ f3AccFlowPointStatsIBRRlMin PerfCounter64,
+ f3AccFlowPointStatsIBR PerfCounter64,
+ f3AccFlowPointStatsIBRRl PerfCounter64,
+ f3AccFlowPointStatsFBCD PerfCounter64,
+ f3AccFlowPointStatsFMCD PerfCounter64,
+ f3AccFlowPointStatsFdRxFb PerfCounter64,
+ f3AccFlowPointStatsFdTxFb PerfCounter64,
+ f3AccFlowPointStatsFdicd PerfCounter64,
+ f3AccFlowPointStatsNumLearnTableFlushes PerfCounter64
+}
+
+f3AccFlowPointStatsIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An arbitrary integer index value used to uniquely identify
+ this Access Ethernet Flowpoint statistics entry.
+ Index 1 corresponds to 15minute, index 2 to 1 day and index
+ 3 corresponds to rollover."
+ ::= { f3AccFlowPointStatsEntry 1 }
+
+f3AccFlowPointStatsIntervalType OBJECT-TYPE
+ SYNTAX CmPmIntervalType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Interval over which Performance Monitoring data is collected."
+ ::= { f3AccFlowPointStatsEntry 2 }
+
+f3AccFlowPointStatsValid OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the validity of the bin."
+ ::= { f3AccFlowPointStatsEntry 3 }
+
+f3AccFlowPointStatsAction OBJECT-TYPE
+ SYNTAX CmPmBinAction
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Allows the Manager to clear the bin."
+ ::= { f3AccFlowPointStatsEntry 4 }
+
+f3AccFlowPointStatsL2CPFD OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Layer 2 Control Protocol Frames Discarded."
+ ::= { f3AccFlowPointStatsEntry 5 }
+
+f3AccFlowPointStatsABRRx OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The average bit rate."
+ ::= { f3AccFlowPointStatsEntry 6 }
+
+f3AccFlowPointStatsABRRLRx OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The average bit rate, rate limited."
+ ::= { f3AccFlowPointStatsEntry 7 }
+
+f3AccFlowPointStatsUAS OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of Unavailable Seconds (UAS)."
+ ::= { f3AccFlowPointStatsEntry 8 }
+
+f3AccFlowPointStatsSES OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of Severely Errored Seconds (ES)."
+ ::= { f3AccFlowPointStatsEntry 9 }
+
+f3AccFlowPointStatsFMG OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of Frames Marked Green."
+ ::= { f3AccFlowPointStatsEntry 10 }
+
+f3AccFlowPointStatsFMY OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of Frames Marked Yellow."
+ ::= { f3AccFlowPointStatsEntry 11 }
+
+f3AccFlowPointStatsFMRD OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of Frames Marked Red and Discarded."
+ ::= { f3AccFlowPointStatsEntry 12 }
+
+f3AccFlowPointStatsFTD OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of Frames Tail Dropped."
+ ::= { f3AccFlowPointStatsEntry 13 }
+
+f3AccFlowPointStatsBytesIn OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of Bytes In in the ingress direction."
+ ::= { f3AccFlowPointStatsEntry 14 }
+
+f3AccFlowPointStatsBytesOut OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of Bytes Out in the ingress direction."
+ ::= { f3AccFlowPointStatsEntry 15 }
+
+f3AccFlowPointStatsIBRMax OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Instantaneous Bit Rate Maximum."
+ ::= { f3AccFlowPointStatsEntry 16 }
+
+f3AccFlowPointStatsIBRRlMax OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Instantaneous Bit Rate Maximum - Rate Limited."
+ ::= { f3AccFlowPointStatsEntry 17 }
+
+f3AccFlowPointStatsIBRMin OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Instantaneous Bit Rate Minimum."
+ ::= { f3AccFlowPointStatsEntry 18 }
+
+f3AccFlowPointStatsIBRRlMin OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Instantaneous Bit Rate Minimum - Rate Limited."
+ ::= { f3AccFlowPointStatsEntry 19 }
+
+f3AccFlowPointStatsIBR OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Instantaneous Bit Rate Minimum."
+ ::= { f3AccFlowPointStatsEntry 20 }
+
+f3AccFlowPointStatsIBRRl OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Instantaneous Bit Rate Minimum - Rate Limited."
+ ::= { f3AccFlowPointStatsEntry 21 }
+
+f3AccFlowPointStatsFBCD OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of Frames Dropped - Broadcast Rate Limit."
+ ::= { f3AccFlowPointStatsEntry 22 }
+
+f3AccFlowPointStatsFMCD OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of Frames Dropped - Multicast Rate Limit."
+ ::= { f3AccFlowPointStatsEntry 23 }
+
+f3AccFlowPointStatsFdRxFb OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of Frames Dropped RX - Flowpoint Blocked."
+ ::= { f3AccFlowPointStatsEntry 24 }
+
+f3AccFlowPointStatsFdTxFb OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of Frames Dropped TX - Flowpoint Blocked."
+ ::= { f3AccFlowPointStatsEntry 25 }
+
+f3AccFlowPointStatsFdicd OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of Frames Dropped - Ingress COS Disabled."
+ ::= { f3AccFlowPointStatsEntry 26 }
+
+f3AccFlowPointStatsNumLearnTableFlushes OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of learning table flushes."
+ ::= { f3AccFlowPointStatsEntry 27 }
+
+--
+-- Network Flowpoint Current Statistics Table
+--
+
+f3NetFlowPointStatsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF F3NetFlowPointStatsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A collection of FlowPoint statistics.
+ These reflect the current data."
+ ::= { f3FpmPerfObjects 2 }
+
+f3NetFlowPointStatsEntry OBJECT-TYPE
+ SYNTAX F3NetFlowPointStatsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A conceptual row in the f3NetFlowPointStatsTable.
+ Entries exist in this table for each FlowPoint."
+ INDEX { neIndex, shelfIndex, slotIndex, cmEthernetNetPortIndex,
+ f3NetFlowPointIndex, f3NetFlowPointStatsIndex }
+ ::= { f3NetFlowPointStatsTable 1 }
+
+F3NetFlowPointStatsEntry ::= SEQUENCE {
+ f3NetFlowPointStatsIndex Integer32,
+ f3NetFlowPointStatsIntervalType CmPmIntervalType,
+ f3NetFlowPointStatsValid TruthValue,
+ f3NetFlowPointStatsAction CmPmBinAction,
+ f3NetFlowPointStatsL2CPFD PerfCounter64,
+ f3NetFlowPointStatsABRRx PerfCounter64,
+ f3NetFlowPointStatsABRRLRx PerfCounter64,
+ f3NetFlowPointStatsUAS PerfCounter64,
+ f3NetFlowPointStatsSES PerfCounter64,
+ f3NetFlowPointStatsFMG PerfCounter64,
+ f3NetFlowPointStatsFMY PerfCounter64,
+ f3NetFlowPointStatsFMRD PerfCounter64,
+ f3NetFlowPointStatsFTD PerfCounter64,
+ f3NetFlowPointStatsBytesIn PerfCounter64,
+ f3NetFlowPointStatsBytesOut PerfCounter64,
+ f3NetFlowPointStatsIBRMax PerfCounter64,
+ f3NetFlowPointStatsIBRRlMax PerfCounter64,
+ f3NetFlowPointStatsIBRMin PerfCounter64,
+ f3NetFlowPointStatsIBRRlMin PerfCounter64,
+ f3NetFlowPointStatsIBR PerfCounter64,
+ f3NetFlowPointStatsIBRRl PerfCounter64,
+ f3NetFlowPointStatsFBCD PerfCounter64,
+ f3NetFlowPointStatsFMCD PerfCounter64,
+ f3NetFlowPointStatsFdRxFb PerfCounter64,
+ f3NetFlowPointStatsFdTxFb PerfCounter64,
+ f3NetFlowPointStatsFdicd PerfCounter64,
+ f3NetFlowPointStatsNumLearnTableFlushes PerfCounter64
+}
+
+f3NetFlowPointStatsIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An arbitrary integer index value used to uniquely identify
+ this Access Ethernet Flowpoint statistics entry.
+ Index 1 corresponds to 15minute, index 2 to 1 day and index
+ 3 corresponds to rollover."
+ ::= { f3NetFlowPointStatsEntry 1 }
+
+f3NetFlowPointStatsIntervalType OBJECT-TYPE
+ SYNTAX CmPmIntervalType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Interval over which Performance Monitoring data is collected."
+ ::= { f3NetFlowPointStatsEntry 2 }
+
+f3NetFlowPointStatsValid OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the validity of the bin."
+ ::= { f3NetFlowPointStatsEntry 3 }
+
+f3NetFlowPointStatsAction OBJECT-TYPE
+ SYNTAX CmPmBinAction
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Allows the Manager to clear the bin."
+ ::= { f3NetFlowPointStatsEntry 4 }
+
+f3NetFlowPointStatsL2CPFD OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Layer 2 Control Protocol Frames Discarded."
+ ::= { f3NetFlowPointStatsEntry 5 }
+
+f3NetFlowPointStatsABRRx OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The average bit rate."
+ ::= { f3NetFlowPointStatsEntry 6 }
+
+f3NetFlowPointStatsABRRLRx OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The average bit rate, rate limited."
+ ::= { f3NetFlowPointStatsEntry 7 }
+
+f3NetFlowPointStatsUAS OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of Unavailable Seconds (UAS)."
+ ::= { f3NetFlowPointStatsEntry 8 }
+
+f3NetFlowPointStatsSES OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of Severely Errored Seconds (ES)."
+ ::= { f3NetFlowPointStatsEntry 9 }
+
+f3NetFlowPointStatsFMG OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of Frames Marked Green."
+ ::= { f3NetFlowPointStatsEntry 10 }
+
+f3NetFlowPointStatsFMY OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of Frames Marked Yellow."
+ ::= { f3NetFlowPointStatsEntry 11 }
+
+f3NetFlowPointStatsFMRD OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of Frames Marked Red and Discarded."
+ ::= { f3NetFlowPointStatsEntry 12 }
+
+f3NetFlowPointStatsFTD OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of Frames Tail Dropped."
+ ::= { f3NetFlowPointStatsEntry 13 }
+
+f3NetFlowPointStatsBytesIn OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of Bytes In in the ingress direction."
+ ::= { f3NetFlowPointStatsEntry 14 }
+
+f3NetFlowPointStatsBytesOut OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of Bytes Out in the ingress direction."
+ ::= { f3NetFlowPointStatsEntry 15 }
+
+f3NetFlowPointStatsIBRMax OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Instantaneous Bit Rate Maximum."
+ ::= { f3NetFlowPointStatsEntry 16 }
+
+f3NetFlowPointStatsIBRRlMax OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Instantaneous Bit Rate Maximum - Rate Limited."
+ ::= { f3NetFlowPointStatsEntry 17 }
+
+f3NetFlowPointStatsIBRMin OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Instantaneous Bit Rate Minimum."
+ ::= { f3NetFlowPointStatsEntry 18 }
+
+f3NetFlowPointStatsIBRRlMin OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Instantaneous Bit Rate Minimum - Rate Limited."
+ ::= { f3NetFlowPointStatsEntry 19 }
+
+f3NetFlowPointStatsIBR OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Instantaneous Bit Rate Minimum."
+ ::= { f3NetFlowPointStatsEntry 20 }
+
+f3NetFlowPointStatsIBRRl OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Instantaneous Bit Rate Minimum - Rate Limited."
+ ::= { f3NetFlowPointStatsEntry 21 }
+
+f3NetFlowPointStatsFBCD OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of Frames Dropped - Broadcast Rate Limit."
+ ::= { f3NetFlowPointStatsEntry 22 }
+
+f3NetFlowPointStatsFMCD OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of Frames Dropped - Multicast Rate Limit."
+ ::= { f3NetFlowPointStatsEntry 23 }
+
+f3NetFlowPointStatsFdRxFb OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of Frames Dropped RX - Flowpoint Blocked."
+ ::= { f3NetFlowPointStatsEntry 24 }
+
+f3NetFlowPointStatsFdTxFb OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of Frames Dropped TX - Flowpoint Blocked."
+ ::= { f3NetFlowPointStatsEntry 25 }
+
+f3NetFlowPointStatsFdicd OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of Frames Dropped - Ingress COS Disabled."
+ ::= { f3NetFlowPointStatsEntry 26 }
+
+f3NetFlowPointStatsNumLearnTableFlushes OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of learning table flushes."
+ ::= { f3NetFlowPointStatsEntry 27 }
+
+--
+-- Access Flowpoint History Statistics Table
+--
+
+f3AccFlowPointHistoryTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF F3AccFlowPointHistoryEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A collection of FlowPoint statistics.
+ These reflect the history data."
+ ::= { f3FpmPerfObjects 3 }
+
+f3AccFlowPointHistoryEntry OBJECT-TYPE
+ SYNTAX F3AccFlowPointHistoryEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A conceptual row in the f3AccFlowPointHistoryTable.
+ Entries exist in this table for each FlowPoint."
+ INDEX { neIndex, shelfIndex, slotIndex, cmEthernetAccPortIndex,
+ f3AccFlowPointIndex, f3AccFlowPointStatsIndex,
+ f3AccFlowPointHistoryIndex }
+ ::= { f3AccFlowPointHistoryTable 1 }
+
+F3AccFlowPointHistoryEntry ::= SEQUENCE {
+ f3AccFlowPointHistoryIndex Integer32,
+ f3AccFlowPointHistoryTime DateAndTime,
+ f3AccFlowPointHistoryValid TruthValue,
+ f3AccFlowPointHistoryAction CmPmBinAction,
+ f3AccFlowPointHistoryL2CPFD PerfCounter64,
+ f3AccFlowPointHistoryABRRx PerfCounter64,
+ f3AccFlowPointHistoryABRRLRx PerfCounter64,
+ f3AccFlowPointHistoryUAS PerfCounter64,
+ f3AccFlowPointHistorySES PerfCounter64,
+ f3AccFlowPointHistoryFMG PerfCounter64,
+ f3AccFlowPointHistoryFMY PerfCounter64,
+ f3AccFlowPointHistoryFMRD PerfCounter64,
+ f3AccFlowPointHistoryFTD PerfCounter64,
+ f3AccFlowPointHistoryBytesIn PerfCounter64,
+ f3AccFlowPointHistoryBytesOut PerfCounter64,
+ f3AccFlowPointHistoryIBRMax PerfCounter64,
+ f3AccFlowPointHistoryIBRRlMax PerfCounter64,
+ f3AccFlowPointHistoryIBRMin PerfCounter64,
+ f3AccFlowPointHistoryIBRRlMin PerfCounter64,
+ f3AccFlowPointHistoryIBR PerfCounter64,
+ f3AccFlowPointHistoryIBRRl PerfCounter64,
+ f3AccFlowPointHistoryFBCD PerfCounter64,
+ f3AccFlowPointHistoryFMCD PerfCounter64,
+ f3AccFlowPointHistoryFdRxFb PerfCounter64,
+ f3AccFlowPointHistoryFdTxFb PerfCounter64,
+ f3AccFlowPointHistoryFdicd PerfCounter64,
+ f3AccFlowPointHistoryNumLearnTableFlushes PerfCounter64
+}
+
+f3AccFlowPointHistoryIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An arbitrary integer index value used to uniquely identify
+ this Access Ethernet Flowpoint History statistics entry.
+ Index 1 corresponds to 15minute, index 2 to 1 day and index
+ 3 corresponds to rollover."
+ ::= { f3AccFlowPointHistoryEntry 1 }
+
+f3AccFlowPointHistoryTime OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the time of history bin creation."
+ ::= { f3AccFlowPointHistoryEntry 2 }
+
+f3AccFlowPointHistoryValid OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the validity of the bin."
+ ::= { f3AccFlowPointHistoryEntry 3 }
+
+f3AccFlowPointHistoryAction OBJECT-TYPE
+ SYNTAX CmPmBinAction
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Allows the Manager to clear the bin."
+ ::= { f3AccFlowPointHistoryEntry 4 }
+
+f3AccFlowPointHistoryL2CPFD OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Layer 2 Control Protocol Frames Discarded."
+ ::= { f3AccFlowPointHistoryEntry 5 }
+
+f3AccFlowPointHistoryABRRx OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The average bit rate."
+ ::= { f3AccFlowPointHistoryEntry 6 }
+
+f3AccFlowPointHistoryABRRLRx OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The average bit rate, rate limited."
+ ::= { f3AccFlowPointHistoryEntry 7 }
+
+f3AccFlowPointHistoryUAS OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of Unavailable Seconds (UAS)."
+ ::= { f3AccFlowPointHistoryEntry 8 }
+
+f3AccFlowPointHistorySES OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of Severely Errored Seconds (ES)."
+ ::= { f3AccFlowPointHistoryEntry 9 }
+
+f3AccFlowPointHistoryFMG OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of Frames Marked Green."
+ ::= { f3AccFlowPointHistoryEntry 10 }
+
+f3AccFlowPointHistoryFMY OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of Frames Marked Yellow."
+ ::= { f3AccFlowPointHistoryEntry 11 }
+
+f3AccFlowPointHistoryFMRD OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of Frames Marked Red and Discarded."
+ ::= { f3AccFlowPointHistoryEntry 12 }
+
+f3AccFlowPointHistoryFTD OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of Frames Tail Dropped."
+ ::= { f3AccFlowPointHistoryEntry 13 }
+
+f3AccFlowPointHistoryBytesIn OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of Bytes In in the ingress direction."
+ ::= { f3AccFlowPointHistoryEntry 14 }
+
+f3AccFlowPointHistoryBytesOut OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of Bytes Out in the ingress direction."
+ ::= { f3AccFlowPointHistoryEntry 15 }
+
+f3AccFlowPointHistoryIBRMax OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Instantaneous Bit Rate Maximum."
+ ::= { f3AccFlowPointHistoryEntry 16 }
+
+f3AccFlowPointHistoryIBRRlMax OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Instantaneous Bit Rate Maximum - Rate Limited."
+ ::= { f3AccFlowPointHistoryEntry 17 }
+
+f3AccFlowPointHistoryIBRMin OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Instantaneous Bit Rate Minimum."
+ ::= { f3AccFlowPointHistoryEntry 18 }
+
+f3AccFlowPointHistoryIBRRlMin OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Instantaneous Bit Rate Minimum - Rate Limited."
+ ::= { f3AccFlowPointHistoryEntry 19 }
+
+f3AccFlowPointHistoryIBR OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Instantaneous Bit Rate Minimum."
+ ::= { f3AccFlowPointHistoryEntry 20 }
+
+f3AccFlowPointHistoryIBRRl OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Instantaneous Bit Rate Minimum - Rate Limited."
+ ::= { f3AccFlowPointHistoryEntry 21 }
+
+f3AccFlowPointHistoryFBCD OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of Frames Dropped - Broadcast Rate Limit."
+ ::= { f3AccFlowPointHistoryEntry 22 }
+
+f3AccFlowPointHistoryFMCD OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of Frames Dropped - Multicast Rate Limit."
+ ::= { f3AccFlowPointHistoryEntry 23 }
+
+f3AccFlowPointHistoryFdRxFb OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of Frames Dropped RX - Flowpoint Blocked."
+ ::= { f3AccFlowPointHistoryEntry 24 }
+
+f3AccFlowPointHistoryFdTxFb OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of Frames Dropped TX - Flowpoint Blocked."
+ ::= { f3AccFlowPointHistoryEntry 25 }
+
+f3AccFlowPointHistoryFdicd OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of Frames Dropped - Ingress COS Disabled."
+ ::= { f3AccFlowPointHistoryEntry 26 }
+
+f3AccFlowPointHistoryNumLearnTableFlushes OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of learning table flushes."
+ ::= { f3AccFlowPointHistoryEntry 27 }
+
+--
+-- Network Flowpoint History Statistics Table
+--
+
+f3NetFlowPointHistoryTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF F3NetFlowPointHistoryEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A collection of FlowPoint statistics.
+ These reflect the history data."
+ ::= { f3FpmPerfObjects 4 }
+
+f3NetFlowPointHistoryEntry OBJECT-TYPE
+ SYNTAX F3NetFlowPointHistoryEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A conceptual row in the f3NetFlowPointHistoryTable.
+ Entries exist in this table for each FlowPoint."
+ INDEX { neIndex, shelfIndex, slotIndex, cmEthernetNetPortIndex,
+ f3NetFlowPointIndex, f3NetFlowPointStatsIndex,
+ f3NetFlowPointHistoryIndex }
+ ::= { f3NetFlowPointHistoryTable 1 }
+
+F3NetFlowPointHistoryEntry ::= SEQUENCE {
+ f3NetFlowPointHistoryIndex Integer32,
+ f3NetFlowPointHistoryTime DateAndTime,
+ f3NetFlowPointHistoryValid TruthValue,
+ f3NetFlowPointHistoryAction CmPmBinAction,
+ f3NetFlowPointHistoryL2CPFD PerfCounter64,
+ f3NetFlowPointHistoryABRRx PerfCounter64,
+ f3NetFlowPointHistoryABRRLRx PerfCounter64,
+ f3NetFlowPointHistoryUAS PerfCounter64,
+ f3NetFlowPointHistorySES PerfCounter64,
+ f3NetFlowPointHistoryFMG PerfCounter64,
+ f3NetFlowPointHistoryFMY PerfCounter64,
+ f3NetFlowPointHistoryFMRD PerfCounter64,
+ f3NetFlowPointHistoryFTD PerfCounter64,
+ f3NetFlowPointHistoryBytesIn PerfCounter64,
+ f3NetFlowPointHistoryBytesOut PerfCounter64,
+ f3NetFlowPointHistoryIBRMax PerfCounter64,
+ f3NetFlowPointHistoryIBRRlMax PerfCounter64,
+ f3NetFlowPointHistoryIBRMin PerfCounter64,
+ f3NetFlowPointHistoryIBRRlMin PerfCounter64,
+ f3NetFlowPointHistoryIBR PerfCounter64,
+ f3NetFlowPointHistoryIBRRl PerfCounter64,
+ f3NetFlowPointHistoryFBCD PerfCounter64,
+ f3NetFlowPointHistoryFMCD PerfCounter64,
+ f3NetFlowPointHistoryFdRxFb PerfCounter64,
+ f3NetFlowPointHistoryFdTxFb PerfCounter64,
+ f3NetFlowPointHistoryFdicd PerfCounter64,
+ f3NetFlowPointHistoryNumLearnTableFlushes PerfCounter64
+}
+
+f3NetFlowPointHistoryIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An arbitrary integer index value used to uniquely identify
+ this Access Ethernet Flowpoint History statistics entry.
+ Index 1 corresponds to 15minute, index 2 to 1 day and index
+ 3 corresponds to rollover."
+ ::= { f3NetFlowPointHistoryEntry 1 }
+
+f3NetFlowPointHistoryTime OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the time of history bin creation."
+ ::= { f3NetFlowPointHistoryEntry 2 }
+
+f3NetFlowPointHistoryValid OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the validity of the bin."
+ ::= { f3NetFlowPointHistoryEntry 3 }
+
+f3NetFlowPointHistoryAction OBJECT-TYPE
+ SYNTAX CmPmBinAction
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Allows the Manager to clear the bin."
+ ::= { f3NetFlowPointHistoryEntry 4 }
+
+f3NetFlowPointHistoryL2CPFD OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Layer 2 Control Protocol Frames Discarded."
+ ::= { f3NetFlowPointHistoryEntry 5 }
+
+f3NetFlowPointHistoryABRRx OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The average bit rate."
+ ::= { f3NetFlowPointHistoryEntry 6 }
+
+f3NetFlowPointHistoryABRRLRx OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The average bit rate, rate limited."
+ ::= { f3NetFlowPointHistoryEntry 7 }
+
+f3NetFlowPointHistoryUAS OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of Unavailable Seconds (UAS)."
+ ::= { f3NetFlowPointHistoryEntry 8 }
+
+f3NetFlowPointHistorySES OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of Severely Errored Seconds (ES)."
+ ::= { f3NetFlowPointHistoryEntry 9 }
+
+f3NetFlowPointHistoryFMG OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of Frames Marked Green."
+ ::= { f3NetFlowPointHistoryEntry 10 }
+
+f3NetFlowPointHistoryFMY OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of Frames Marked Yellow."
+ ::= { f3NetFlowPointHistoryEntry 11 }
+
+f3NetFlowPointHistoryFMRD OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of Frames Marked Red and Discarded."
+ ::= { f3NetFlowPointHistoryEntry 12 }
+
+f3NetFlowPointHistoryFTD OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of Frames Tail Dropped."
+ ::= { f3NetFlowPointHistoryEntry 13 }
+
+f3NetFlowPointHistoryBytesIn OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of Bytes In in the ingress direction."
+ ::= { f3NetFlowPointHistoryEntry 14 }
+
+f3NetFlowPointHistoryBytesOut OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of Bytes Out in the ingress direction."
+ ::= { f3NetFlowPointHistoryEntry 15 }
+
+f3NetFlowPointHistoryIBRMax OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Instantaneous Bit Rate Maximum."
+ ::= { f3NetFlowPointHistoryEntry 16 }
+
+f3NetFlowPointHistoryIBRRlMax OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Instantaneous Bit Rate Maximum - Rate Limited."
+ ::= { f3NetFlowPointHistoryEntry 17 }
+
+f3NetFlowPointHistoryIBRMin OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Instantaneous Bit Rate Minimum."
+ ::= { f3NetFlowPointHistoryEntry 18 }
+
+f3NetFlowPointHistoryIBRRlMin OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Instantaneous Bit Rate Minimum - Rate Limited."
+ ::= { f3NetFlowPointHistoryEntry 19 }
+
+f3NetFlowPointHistoryIBR OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Instantaneous Bit Rate Minimum."
+ ::= { f3NetFlowPointHistoryEntry 20 }
+
+f3NetFlowPointHistoryIBRRl OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Instantaneous Bit Rate Minimum - Rate Limited."
+ ::= { f3NetFlowPointHistoryEntry 21 }
+
+f3NetFlowPointHistoryFBCD OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of Frames Dropped - Broadcast Rate Limit."
+ ::= { f3NetFlowPointHistoryEntry 22 }
+
+f3NetFlowPointHistoryFMCD OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of Frames Dropped - Multicast Rate Limit."
+ ::= { f3NetFlowPointHistoryEntry 23 }
+
+f3NetFlowPointHistoryFdRxFb OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of Frames Dropped RX - Flowpoint Blocked."
+ ::= { f3NetFlowPointHistoryEntry 24 }
+
+f3NetFlowPointHistoryFdTxFb OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of Frames Dropped TX - Flowpoint Blocked."
+ ::= { f3NetFlowPointHistoryEntry 25 }
+
+f3NetFlowPointHistoryFdicd OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of Frames Dropped - Ingress COS Disabled."
+ ::= { f3NetFlowPointHistoryEntry 26 }
+
+f3NetFlowPointHistoryNumLearnTableFlushes OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of learning table flushes."
+ ::= { f3NetFlowPointHistoryEntry 27 }
+
+--
+-- Access FlowPoint Threshold Table
+--
+
+f3AccFlowPointThresholdTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF F3AccFlowPointThresholdEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of entries that allow manageability of Agg FlowPoint Thresholds."
+ ::= { f3FpmPerfObjects 5 }
+
+f3AccFlowPointThresholdEntry OBJECT-TYPE
+ SYNTAX F3AccFlowPointThresholdEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A conceptual row in the f3AccFlowPointThresholdTable."
+ INDEX { neIndex, shelfIndex, slotIndex, cmEthernetAccPortIndex,
+ f3AccFlowPointIndex, f3AccFlowPointStatsIndex, f3AccFlowPointThresholdIndex }
+ ::= { f3AccFlowPointThresholdTable 1 }
+
+F3AccFlowPointThresholdEntry ::= SEQUENCE {
+ f3AccFlowPointThresholdIndex Integer32,
+ f3AccFlowPointThresholdInterval CmPmIntervalType,
+ f3AccFlowPointThresholdVariable VariablePointer,
+ f3AccFlowPointThresholdValueLo Unsigned32,
+ f3AccFlowPointThresholdValueHi Unsigned32,
+ f3AccFlowPointThresholdMonValue Counter64
+}
+
+f3AccFlowPointThresholdIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An index that uniquely identifies an entry in the
+ f3AccFlowPointThresholdTable."
+ ::= { f3AccFlowPointThresholdEntry 1 }
+
+f3AccFlowPointThresholdInterval OBJECT-TYPE
+ SYNTAX CmPmIntervalType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The interval over which monitored value is
+ sampled and compared with the specified threshold."
+ ::= { f3AccFlowPointThresholdEntry 2 }
+
+f3AccFlowPointThresholdVariable OBJECT-TYPE
+ SYNTAX VariablePointer
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The object identifier of the particular variable to be sampled."
+ ::= { f3AccFlowPointThresholdEntry 3 }
+
+f3AccFlowPointThresholdValueLo OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Lower 32 bits of the threshold value."
+ ::= { f3AccFlowPointThresholdEntry 4 }
+
+f3AccFlowPointThresholdValueHi OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Higher 32 bits of the threshold value."
+ ::= { f3AccFlowPointThresholdEntry 5 }
+
+f3AccFlowPointThresholdMonValue OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Monitored value corresponding to f3AccFlowPointThresholdVariable."
+ ::= { f3AccFlowPointThresholdEntry 6 }
+
+--
+-- Network FlowPoint Threshold Table
+--
+
+f3NetFlowPointThresholdTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF F3NetFlowPointThresholdEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of entries that allow manageability of Agg FlowPoint Thresholds."
+ ::= { f3FpmPerfObjects 6 }
+
+f3NetFlowPointThresholdEntry OBJECT-TYPE
+ SYNTAX F3NetFlowPointThresholdEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A conceptual row in the f3NetFlowPointThresholdTable."
+ INDEX { neIndex, shelfIndex, slotIndex, cmEthernetNetPortIndex,
+ f3NetFlowPointIndex, f3NetFlowPointStatsIndex, f3NetFlowPointThresholdIndex }
+ ::= { f3NetFlowPointThresholdTable 1 }
+
+F3NetFlowPointThresholdEntry ::= SEQUENCE {
+ f3NetFlowPointThresholdIndex Integer32,
+ f3NetFlowPointThresholdInterval CmPmIntervalType,
+ f3NetFlowPointThresholdVariable VariablePointer,
+ f3NetFlowPointThresholdValueLo Unsigned32,
+ f3NetFlowPointThresholdValueHi Unsigned32,
+ f3NetFlowPointThresholdMonValue Counter64
+}
+
+f3NetFlowPointThresholdIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An index that uniquely identifies an entry in the
+ f3NetFlowPointThresholdTable."
+ ::= { f3NetFlowPointThresholdEntry 1 }
+
+f3NetFlowPointThresholdInterval OBJECT-TYPE
+ SYNTAX CmPmIntervalType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The interval over which monitored value is
+ sampled and compared with the specified threshold."
+ ::= { f3NetFlowPointThresholdEntry 2 }
+
+f3NetFlowPointThresholdVariable OBJECT-TYPE
+ SYNTAX VariablePointer
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The object identifier of the particular variable to be sampled."
+ ::= { f3NetFlowPointThresholdEntry 3 }
+
+f3NetFlowPointThresholdValueLo OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Lower 32 bits of the threshold value."
+ ::= { f3NetFlowPointThresholdEntry 4 }
+
+f3NetFlowPointThresholdValueHi OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Higher 32 bits of the threshold value."
+ ::= { f3NetFlowPointThresholdEntry 5 }
+
+f3NetFlowPointThresholdMonValue OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Monitored value corresponding to f3NetFlowPointThresholdVariable."
+ ::= { f3NetFlowPointThresholdEntry 6 }
+
+--
+-- MP Flow Current Statistics Table
+--
+
+f3MPFlowStatsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF F3MPFlowStatsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A collection of MP Flow statistics.
+ These reflect the current data."
+ ::= { f3FpmPerfObjects 7 }
+
+f3MPFlowStatsEntry OBJECT-TYPE
+ SYNTAX F3MPFlowStatsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A conceptual row in the f3MPFlowStatsTable.
+ Entries exist in this table for each MP Flow."
+ INDEX { neIndex, cmMPFlowIndex, f3MPFlowStatsIndex }
+ ::= { f3MPFlowStatsTable 1 }
+
+F3MPFlowStatsEntry ::= SEQUENCE {
+ f3MPFlowStatsIndex Integer32,
+ f3MPFlowStatsIntervalType CmPmIntervalType,
+ f3MPFlowStatsValid TruthValue,
+ f3MPFlowStatsAction CmPmBinAction,
+ f3MPFlowStatsFDStaticBlock PerfCounter64,
+ f3MPFlowStatsFDHairPin PerfCounter64,
+ f3MPFlowStatsMacTableDiscards PerfCounter64,
+ f3MPFlowStatsFDProtLearn PerfCounter64
+}
+
+f3MPFlowStatsIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An arbitrary integer index value used to uniquely identify
+ this MP Flow statistics entry. Index 1 corresponds to 15minute,
+ index 2 to 1 day and index 3 corresponds to rollover."
+ ::= { f3MPFlowStatsEntry 1 }
+
+f3MPFlowStatsIntervalType OBJECT-TYPE
+ SYNTAX CmPmIntervalType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Interval over which Performance Monitoring data is collected."
+ ::= { f3MPFlowStatsEntry 2 }
+
+f3MPFlowStatsValid OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the validity of the bin."
+ ::= { f3MPFlowStatsEntry 3 }
+
+f3MPFlowStatsAction OBJECT-TYPE
+ SYNTAX CmPmBinAction
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Allows the Manager to clear the bin."
+ ::= { f3MPFlowStatsEntry 4 }
+
+f3MPFlowStatsFDStaticBlock OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Specifies current counter for number of frames discarded due to a
+ static entry in Mac Table."
+ ::= { f3MPFlowStatsEntry 5 }
+
+f3MPFlowStatsFDHairPin OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Specifies current counter for number of frames discarded because
+ destination Port is the ingress flowpoint or destination Port is in the
+ same Split Horizon Group."
+ ::= { f3MPFlowStatsEntry 6 }
+
+f3MPFlowStatsMacTableDiscards OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Specifies current counter for total number of MAC Table entries that have
+ been or would have been learned, but have been failed due to a lack of
+ storage space in the Filtering Database."
+ ::= { f3MPFlowStatsEntry 7 }
+
+f3MPFlowStatsFDProtLearn OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Specifies current counter for number
+ of frames dropped - protection learning."
+ ::= { f3MPFlowStatsEntry 8 }
+
+--
+-- MP Flow History Statistics Table
+--
+
+f3MPFlowHistoryTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF F3MPFlowHistoryEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A collection of MP Flow statistics.
+ These reflect the history data."
+ ::= { f3FpmPerfObjects 8 }
+
+f3MPFlowHistoryEntry OBJECT-TYPE
+ SYNTAX F3MPFlowHistoryEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A conceptual row in the f3MPFlowHistoryTable.
+ Entries exist in this table for each MP Flow."
+ INDEX { neIndex, cmMPFlowIndex, f3MPFlowStatsIndex, f3MPFlowHistoryIndex }
+ ::= { f3MPFlowHistoryTable 1 }
+
+F3MPFlowHistoryEntry ::= SEQUENCE {
+ f3MPFlowHistoryIndex Integer32,
+ f3MPFlowHistoryTime DateAndTime,
+ f3MPFlowHistoryValid TruthValue,
+ f3MPFlowHistoryAction CmPmBinAction,
+ f3MPFlowHistoryFDStaticBlock PerfCounter64,
+ f3MPFlowHistoryFDHairPin PerfCounter64,
+ f3MPFlowHistoryMacTableDiscards PerfCounter64,
+ f3MPFlowHistoryFDProtLearn PerfCounter64
+}
+
+f3MPFlowHistoryIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An arbitrary integer index value used to uniquely identify
+ this MP Flow History statistics entry. Index 1 corresponds to 15minute,
+ index 2 to 1 day and index 3 corresponds to rollover."
+ ::= { f3MPFlowHistoryEntry 1 }
+
+f3MPFlowHistoryTime OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the time of history bin creation."
+ ::= { f3MPFlowHistoryEntry 2 }
+
+f3MPFlowHistoryValid OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the validity of the bin."
+ ::= { f3MPFlowHistoryEntry 3 }
+
+f3MPFlowHistoryAction OBJECT-TYPE
+ SYNTAX CmPmBinAction
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Allows the Manager to clear the bin."
+ ::= { f3MPFlowHistoryEntry 4 }
+
+f3MPFlowHistoryFDStaticBlock OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Specifies history bin for number of frames discarded due to a
+ static entry in Mac Table."
+ ::= { f3MPFlowHistoryEntry 5 }
+
+f3MPFlowHistoryFDHairPin OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Specifies history bin for number of frames discarded because
+ destination Port is the ingress flowpoint or destination Port is in the
+ same Split Horizon Group."
+ ::= { f3MPFlowHistoryEntry 6 }
+
+f3MPFlowHistoryMacTableDiscards OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Specifies history bin for total number of MAC Table entries that have
+ been or would have been learned, but have been failed due to a lack of
+ storage space in the Filtering Database."
+ ::= { f3MPFlowHistoryEntry 7 }
+
+f3MPFlowHistoryFDProtLearn OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Specifies history bin for total number
+ of frames dropped - protection learning."
+ ::= { f3MPFlowHistoryEntry 8 }
+
+--
+-- MP Flow Threshold Table
+--
+
+f3MPFlowThresholdTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF F3MPFlowThresholdEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of entries that allow manageability of MP Flow Thresholds."
+ ::= { f3FpmPerfObjects 9 }
+
+f3MPFlowThresholdEntry OBJECT-TYPE
+ SYNTAX F3MPFlowThresholdEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A conceptual row in the f3MPFlowThresholdTable."
+ INDEX { neIndex, cmMPFlowIndex, f3MPFlowStatsIndex, f3MPFlowThresholdIndex }
+ ::= { f3MPFlowThresholdTable 1 }
+
+F3MPFlowThresholdEntry ::= SEQUENCE {
+ f3MPFlowThresholdIndex Integer32,
+ f3MPFlowThresholdInterval CmPmIntervalType,
+ f3MPFlowThresholdVariable VariablePointer,
+ f3MPFlowThresholdValueLo Unsigned32,
+ f3MPFlowThresholdValueHi Unsigned32,
+ f3MPFlowThresholdMonValue Counter64
+}
+
+f3MPFlowThresholdIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An index that uniquely identifies an entry in the
+ f3MPFlowThresholdTable."
+ ::= { f3MPFlowThresholdEntry 1 }
+
+f3MPFlowThresholdInterval OBJECT-TYPE
+ SYNTAX CmPmIntervalType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The interval over which monitored value is
+ sampled and compared with the specified threshold."
+ ::= { f3MPFlowThresholdEntry 2 }
+
+f3MPFlowThresholdVariable OBJECT-TYPE
+ SYNTAX VariablePointer
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The object identifier of the particular variable to be sampled."
+ ::= { f3MPFlowThresholdEntry 3 }
+
+f3MPFlowThresholdValueLo OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Lower 32 bits of the threshold value."
+ ::= { f3MPFlowThresholdEntry 4 }
+
+f3MPFlowThresholdValueHi OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Higher 32 bits of the threshold value."
+ ::= { f3MPFlowThresholdEntry 5 }
+
+f3MPFlowThresholdMonValue OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Monitored value corresponding to f3MPFlowThresholdVariable."
+ ::= { f3MPFlowThresholdEntry 6 }
+
+--
+-- Access Flow Point QoS Shaper Current Statistics Table
+--
+
+f3AccFpQosShaperStatsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF F3AccFpQosShaperStatsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A collection of Acc FlowPoint QOS Shaper statistics.
+ These reflect the current data."
+ ::= { f3FpmPerfObjects 10 }
+
+f3AccFpQosShaperStatsEntry OBJECT-TYPE
+ SYNTAX F3AccFpQosShaperStatsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A conceptual row in the f3AccFpQosShaperStatsTable.
+ Entries exist in this table for each FlowPoint QoS Shaper."
+ INDEX { neIndex, shelfIndex, slotIndex, cmEthernetAccPortIndex,
+ f3AccFlowPointIndex, f3AccFpQosShaperIndex,
+ f3AccFpQosShaperStatsIndex }
+ ::= { f3AccFpQosShaperStatsTable 1 }
+
+F3AccFpQosShaperStatsEntry ::= SEQUENCE {
+ f3AccFpQosShaperStatsIndex Integer32,
+ f3AccFpQosShaperStatsIntervalType CmPmIntervalType,
+ f3AccFpQosShaperStatsValid TruthValue,
+ f3AccFpQosShaperStatsAction CmPmBinAction,
+ f3AccFpQosShaperStatsBT PerfCounter64,
+ f3AccFpQosShaperStatsBTD PerfCounter64,
+ f3AccFpQosShaperStatsFD PerfCounter64,
+ f3AccFpQosShaperStatsFTD PerfCounter64,
+ f3AccFpQosShaperStatsABRRL PerfCounter64,
+ f3AccFpQosShaperStatsBREDD PerfCounter64,
+ f3AccFpQosShaperStatsFREDD PerfCounter64
+}
+
+f3AccFpQosShaperStatsIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An arbitrary integer index value used to uniquely identify
+ this QOS Shaper statistics entry.
+ 1 - 15min
+ 2 - 1day
+ 3 - rollover
+ 4 - 5min"
+ ::= { f3AccFpQosShaperStatsEntry 1 }
+
+f3AccFpQosShaperStatsIntervalType OBJECT-TYPE
+ SYNTAX CmPmIntervalType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Interval over which Performance Monitoring data is collected."
+ ::= { f3AccFpQosShaperStatsEntry 2 }
+
+f3AccFpQosShaperStatsValid OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the validity of the bin."
+ ::= { f3AccFpQosShaperStatsEntry 3 }
+
+f3AccFpQosShaperStatsAction OBJECT-TYPE
+ SYNTAX CmPmBinAction
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Allows the Manager to clear the bin."
+ ::= { f3AccFpQosShaperStatsEntry 4 }
+
+f3AccFpQosShaperStatsBT OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Bytes Transmitted."
+ ::= { f3AccFpQosShaperStatsEntry 5 }
+
+f3AccFpQosShaperStatsBTD OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Bytes Tail Dropped."
+ ::= { f3AccFpQosShaperStatsEntry 6 }
+
+f3AccFpQosShaperStatsFD OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Frames Dequeued."
+ ::= { f3AccFpQosShaperStatsEntry 7 }
+
+f3AccFpQosShaperStatsFTD OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Frames Tail Dropped."
+ ::= { f3AccFpQosShaperStatsEntry 8 }
+
+f3AccFpQosShaperStatsABRRL OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Average Bit Rate - Rate Limited."
+ ::= { f3AccFpQosShaperStatsEntry 9 }
+
+f3AccFpQosShaperStatsBREDD OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Bytes Random Early Discard, Dropped."
+ ::= { f3AccFpQosShaperStatsEntry 10 }
+
+f3AccFpQosShaperStatsFREDD OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Frames Random Early Discard, Dropped."
+ ::= { f3AccFpQosShaperStatsEntry 11 }
+
+--
+-- Access Flow Point QoS Shaper History Statistics Table
+--
+
+f3AccFpQosShaperHistoryTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF F3AccFpQosShaperHistoryEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A collection of Acc FlowPoint QOS Shaper statistics.
+ These reflect the history data."
+ ::= { f3FpmPerfObjects 11 }
+
+f3AccFpQosShaperHistoryEntry OBJECT-TYPE
+ SYNTAX F3AccFpQosShaperHistoryEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A conceptual row in the f3AccFpQosShaperHistoryTable.
+ Entries exist in this table for each FlowPoint QoS Shaper."
+ INDEX { neIndex, shelfIndex, slotIndex, cmEthernetAccPortIndex,
+ f3AccFlowPointIndex, f3AccFpQosShaperIndex,
+ f3AccFpQosShaperStatsIndex, f3AccFpQosShaperHistoryIndex }
+ ::= { f3AccFpQosShaperHistoryTable 1 }
+
+F3AccFpQosShaperHistoryEntry ::= SEQUENCE {
+ f3AccFpQosShaperHistoryIndex Integer32,
+ f3AccFpQosShaperHistoryTime DateAndTime,
+ f3AccFpQosShaperHistoryValid TruthValue,
+ f3AccFpQosShaperHistoryAction CmPmBinAction,
+ f3AccFpQosShaperHistoryBT PerfCounter64,
+ f3AccFpQosShaperHistoryBTD PerfCounter64,
+ f3AccFpQosShaperHistoryFD PerfCounter64,
+ f3AccFpQosShaperHistoryFTD PerfCounter64,
+ f3AccFpQosShaperHistoryABRRL PerfCounter64,
+ f3AccFpQosShaperHistoryBREDD PerfCounter64,
+ f3AccFpQosShaperHistoryFREDD PerfCounter64
+}
+
+f3AccFpQosShaperHistoryIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An arbitrary integer index value used to uniquely identify
+ this QOS Shaper statistics entry."
+ ::= { f3AccFpQosShaperHistoryEntry 1 }
+
+f3AccFpQosShaperHistoryTime OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the time of history bin creation."
+ ::= { f3AccFpQosShaperHistoryEntry 2 }
+
+f3AccFpQosShaperHistoryValid OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the validity of the bin."
+ ::= { f3AccFpQosShaperHistoryEntry 3 }
+
+f3AccFpQosShaperHistoryAction OBJECT-TYPE
+ SYNTAX CmPmBinAction
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Allows the Manager to clear the bin."
+ ::= { f3AccFpQosShaperHistoryEntry 4 }
+
+f3AccFpQosShaperHistoryBT OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Bytes Transmitted."
+ ::= { f3AccFpQosShaperHistoryEntry 5 }
+
+f3AccFpQosShaperHistoryBTD OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Bytes Tail Dropped."
+ ::= { f3AccFpQosShaperHistoryEntry 6 }
+
+f3AccFpQosShaperHistoryFD OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Frames Dequeued."
+ ::= { f3AccFpQosShaperHistoryEntry 7 }
+
+f3AccFpQosShaperHistoryFTD OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Frames Tail Dropped."
+ ::= { f3AccFpQosShaperHistoryEntry 8 }
+
+f3AccFpQosShaperHistoryABRRL OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Average Bit Rate - Rate Limited."
+ ::= { f3AccFpQosShaperHistoryEntry 9 }
+
+f3AccFpQosShaperHistoryBREDD OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Bytes Random Early Discard, Dropped."
+ ::= { f3AccFpQosShaperHistoryEntry 10 }
+
+f3AccFpQosShaperHistoryFREDD OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Frames Random Early Discard, Dropped."
+ ::= { f3AccFpQosShaperHistoryEntry 11 }
+
+--
+-- Access Flow Point QoS Shaper Threshold Table
+--
+
+f3AccFpQosShaperThresholdTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF F3AccFpQosShaperThresholdEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of entries that allow manageability of Acc FlowPoint
+ QoS Shaper Thresholds."
+ ::= { f3FpmPerfObjects 12 }
+
+f3AccFpQosShaperThresholdEntry OBJECT-TYPE
+ SYNTAX F3AccFpQosShaperThresholdEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A conceptual row in the f3AccFpQosShaperThresholdTable."
+ INDEX { neIndex, shelfIndex, slotIndex, cmEthernetAccPortIndex,
+ f3AccFlowPointIndex, f3AccFpQosShaperIndex,
+ f3AccFpQosShaperStatsIndex, f3AccFpQosShaperThresholdIndex }
+ ::= { f3AccFpQosShaperThresholdTable 1 }
+
+F3AccFpQosShaperThresholdEntry ::= SEQUENCE {
+ f3AccFpQosShaperThresholdIndex Integer32,
+ f3AccFpQosShaperThresholdInterval CmPmIntervalType,
+ f3AccFpQosShaperThresholdVariable VariablePointer,
+ f3AccFpQosShaperThresholdValueLo Unsigned32,
+ f3AccFpQosShaperThresholdValueHi Unsigned32,
+ f3AccFpQosShaperThresholdMonValue Counter64
+}
+
+f3AccFpQosShaperThresholdIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An index that uniquely identifies an entry in the
+ f3AccFpQosShaperThresholdTable."
+ ::= { f3AccFpQosShaperThresholdEntry 1 }
+
+f3AccFpQosShaperThresholdInterval OBJECT-TYPE
+ SYNTAX CmPmIntervalType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The interval over which monitored value is
+ sampled and compared with the specified threshold."
+ ::= { f3AccFpQosShaperThresholdEntry 2 }
+
+f3AccFpQosShaperThresholdVariable OBJECT-TYPE
+ SYNTAX VariablePointer
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The object identifier of the particular variable to be
+ sampled."
+ ::= { f3AccFpQosShaperThresholdEntry 3 }
+
+f3AccFpQosShaperThresholdValueLo OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Lower 32 bits of the threshold value."
+ ::= { f3AccFpQosShaperThresholdEntry 4 }
+
+f3AccFpQosShaperThresholdValueHi OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Higher 32 bits of the threshold value."
+ ::= { f3AccFpQosShaperThresholdEntry 5 }
+
+f3AccFpQosShaperThresholdMonValue OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Monitored value corresponding to f3AccFpQosShaperThresholdVariable."
+ ::= { f3AccFpQosShaperThresholdEntry 6 }
+
+--
+-- Network Flow Point QoS Shaper Current Statistics Table
+--
+
+f3NetFpQosShaperStatsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF F3NetFpQosShaperStatsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A collection of Net FlowPoint QOS Shaper statistics.
+ These reflect the current data."
+ ::= { f3FpmPerfObjects 13 }
+
+f3NetFpQosShaperStatsEntry OBJECT-TYPE
+ SYNTAX F3NetFpQosShaperStatsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A conceptual row in the f3NetFpQosShaperStatsTable.
+ Entries exist in this table for each FlowPoint QoS Shaper."
+ INDEX { neIndex, shelfIndex, slotIndex, cmEthernetNetPortIndex,
+ f3NetFlowPointIndex, f3NetFpQosShaperIndex,
+ f3NetFpQosShaperStatsIndex }
+ ::= { f3NetFpQosShaperStatsTable 1 }
+
+F3NetFpQosShaperStatsEntry ::= SEQUENCE {
+ f3NetFpQosShaperStatsIndex Integer32,
+ f3NetFpQosShaperStatsIntervalType CmPmIntervalType,
+ f3NetFpQosShaperStatsValid TruthValue,
+ f3NetFpQosShaperStatsAction CmPmBinAction,
+ f3NetFpQosShaperStatsBT PerfCounter64,
+ f3NetFpQosShaperStatsBTD PerfCounter64,
+ f3NetFpQosShaperStatsFD PerfCounter64,
+ f3NetFpQosShaperStatsFTD PerfCounter64,
+ f3NetFpQosShaperStatsABRRL PerfCounter64,
+ f3NetFpQosShaperStatsBREDD PerfCounter64,
+ f3NetFpQosShaperStatsFREDD PerfCounter64
+}
+
+f3NetFpQosShaperStatsIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An arbitrary integer index value used to uniquely identify
+ this QOS Shaper statistics entry.
+ 1 - 15min
+ 2 - 1day
+ 3 - rollover
+ 4 - 5min"
+ ::= { f3NetFpQosShaperStatsEntry 1 }
+
+f3NetFpQosShaperStatsIntervalType OBJECT-TYPE
+ SYNTAX CmPmIntervalType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Interval over which Performance Monitoring data is collected."
+ ::= { f3NetFpQosShaperStatsEntry 2 }
+
+f3NetFpQosShaperStatsValid OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the validity of the bin."
+ ::= { f3NetFpQosShaperStatsEntry 3 }
+
+f3NetFpQosShaperStatsAction OBJECT-TYPE
+ SYNTAX CmPmBinAction
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Allows the Manager to clear the bin."
+ ::= { f3NetFpQosShaperStatsEntry 4 }
+
+f3NetFpQosShaperStatsBT OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Bytes Transmitted."
+ ::= { f3NetFpQosShaperStatsEntry 5 }
+
+f3NetFpQosShaperStatsBTD OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Bytes Tail Dropped."
+ ::= { f3NetFpQosShaperStatsEntry 6 }
+
+f3NetFpQosShaperStatsFD OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Frames Dequeued."
+ ::= { f3NetFpQosShaperStatsEntry 7 }
+
+f3NetFpQosShaperStatsFTD OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Frames Tail Dropped."
+ ::= { f3NetFpQosShaperStatsEntry 8 }
+
+f3NetFpQosShaperStatsABRRL OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Average Bit Rate - Rate Limited."
+ ::= { f3NetFpQosShaperStatsEntry 9 }
+
+f3NetFpQosShaperStatsBREDD OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Bytes Random Early Discard, Dropped."
+ ::= { f3NetFpQosShaperStatsEntry 10 }
+
+f3NetFpQosShaperStatsFREDD OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Frames Random Early Discard, Dropped."
+ ::= { f3NetFpQosShaperStatsEntry 11 }
+
+--
+-- Network Flow Point QoS Shaper History Statistics Table
+--
+
+f3NetFpQosShaperHistoryTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF F3NetFpQosShaperHistoryEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A collection of Net FlowPoint QOS Shaper statistics.
+ These reflect the history data."
+ ::= { f3FpmPerfObjects 14 }
+
+f3NetFpQosShaperHistoryEntry OBJECT-TYPE
+ SYNTAX F3NetFpQosShaperHistoryEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A conceptual row in the f3NetFpQosShaperHistoryTable.
+ Entries exist in this table for each FlowPoint QoS Shaper."
+ INDEX { neIndex, shelfIndex, slotIndex, cmEthernetNetPortIndex,
+ f3NetFlowPointIndex, f3NetFpQosShaperIndex,
+ f3NetFpQosShaperStatsIndex, f3NetFpQosShaperHistoryIndex }
+ ::= { f3NetFpQosShaperHistoryTable 1 }
+
+F3NetFpQosShaperHistoryEntry ::= SEQUENCE {
+ f3NetFpQosShaperHistoryIndex Integer32,
+ f3NetFpQosShaperHistoryTime DateAndTime,
+ f3NetFpQosShaperHistoryValid TruthValue,
+ f3NetFpQosShaperHistoryAction CmPmBinAction,
+ f3NetFpQosShaperHistoryBT PerfCounter64,
+ f3NetFpQosShaperHistoryBTD PerfCounter64,
+ f3NetFpQosShaperHistoryFD PerfCounter64,
+ f3NetFpQosShaperHistoryFTD PerfCounter64,
+ f3NetFpQosShaperHistoryABRRL PerfCounter64,
+ f3NetFpQosShaperHistoryBREDD PerfCounter64,
+ f3NetFpQosShaperHistoryFREDD PerfCounter64
+}
+
+f3NetFpQosShaperHistoryIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An arbitrary integer index value used to uniquely identify
+ this QOS Shaper statistics entry."
+ ::= { f3NetFpQosShaperHistoryEntry 1 }
+
+f3NetFpQosShaperHistoryTime OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the time of history bin creation."
+ ::= { f3NetFpQosShaperHistoryEntry 2 }
+
+f3NetFpQosShaperHistoryValid OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the validity of the bin."
+ ::= { f3NetFpQosShaperHistoryEntry 3 }
+
+f3NetFpQosShaperHistoryAction OBJECT-TYPE
+ SYNTAX CmPmBinAction
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Allows the Manager to clear the bin."
+ ::= { f3NetFpQosShaperHistoryEntry 4 }
+
+f3NetFpQosShaperHistoryBT OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Bytes Transmitted."
+ ::= { f3NetFpQosShaperHistoryEntry 5 }
+
+f3NetFpQosShaperHistoryBTD OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Bytes Tail Dropped."
+ ::= { f3NetFpQosShaperHistoryEntry 6 }
+
+f3NetFpQosShaperHistoryFD OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Frames Dequeued."
+ ::= { f3NetFpQosShaperHistoryEntry 7 }
+
+f3NetFpQosShaperHistoryFTD OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Frames Tail Dropped."
+ ::= { f3NetFpQosShaperHistoryEntry 8 }
+
+f3NetFpQosShaperHistoryABRRL OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Average Bit Rate - Rate Limited."
+ ::= { f3NetFpQosShaperHistoryEntry 9 }
+
+f3NetFpQosShaperHistoryBREDD OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Bytes Random Early Discard, Dropped."
+ ::= { f3NetFpQosShaperHistoryEntry 10 }
+
+f3NetFpQosShaperHistoryFREDD OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Frames Random Early Discard, Dropped."
+ ::= { f3NetFpQosShaperHistoryEntry 11 }
+
+--
+-- Network Flow Point QoS Shaper Threshold Table
+--
+
+f3NetFpQosShaperThresholdTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF F3NetFpQosShaperThresholdEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of entries that allow manageability of Net FlowPoint
+ QoS Shaper Thresholds."
+ ::= { f3FpmPerfObjects 15 }
+
+f3NetFpQosShaperThresholdEntry OBJECT-TYPE
+ SYNTAX F3NetFpQosShaperThresholdEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A conceptual row in the f3NetFpQosShaperThresholdTable."
+ INDEX { neIndex, shelfIndex, slotIndex, cmEthernetNetPortIndex,
+ f3NetFlowPointIndex, f3NetFpQosShaperIndex,
+ f3NetFpQosShaperStatsIndex, f3NetFpQosShaperThresholdIndex }
+ ::= { f3NetFpQosShaperThresholdTable 1 }
+
+F3NetFpQosShaperThresholdEntry ::= SEQUENCE {
+ f3NetFpQosShaperThresholdIndex Integer32,
+ f3NetFpQosShaperThresholdInterval CmPmIntervalType,
+ f3NetFpQosShaperThresholdVariable VariablePointer,
+ f3NetFpQosShaperThresholdValueLo Unsigned32,
+ f3NetFpQosShaperThresholdValueHi Unsigned32,
+ f3NetFpQosShaperThresholdMonValue Counter64
+}
+
+f3NetFpQosShaperThresholdIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An index that uniquely identifies an entry in the
+ f3NetFpQosShaperThresholdTable."
+ ::= { f3NetFpQosShaperThresholdEntry 1 }
+
+f3NetFpQosShaperThresholdInterval OBJECT-TYPE
+ SYNTAX CmPmIntervalType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The interval over which monitored value is
+ sampled and compared with the specified threshold."
+ ::= { f3NetFpQosShaperThresholdEntry 2 }
+
+f3NetFpQosShaperThresholdVariable OBJECT-TYPE
+ SYNTAX VariablePointer
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The object identifier of the particular variable to be
+ sampled."
+ ::= { f3NetFpQosShaperThresholdEntry 3 }
+
+f3NetFpQosShaperThresholdValueLo OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Lower 32 bits of the threshold value."
+ ::= { f3NetFpQosShaperThresholdEntry 4 }
+
+f3NetFpQosShaperThresholdValueHi OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Higher 32 bits of the threshold value."
+ ::= { f3NetFpQosShaperThresholdEntry 5 }
+
+f3NetFpQosShaperThresholdMonValue OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Monitored value corresponding to f3NetFpQosShaperThresholdVariable."
+ ::= { f3NetFpQosShaperThresholdEntry 6 }
+
+--
+-- Access Flow Point QoS Policer Current Statistics Table
+--
+
+f3AccFpQosPolicerStatsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF F3AccFpQosPolicerStatsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A collection of Acc FlowPoint QOS Policer statistics.
+ These reflect the current data."
+ ::= { f3FpmPerfObjects 16 }
+
+f3AccFpQosPolicerStatsEntry OBJECT-TYPE
+ SYNTAX F3AccFpQosPolicerStatsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A conceptual row in the f3AccFpQosPolicerStatsTable.
+ Entries exist in this table for each Acc FlowPoint QoS Policer."
+ INDEX { neIndex, shelfIndex, slotIndex, cmEthernetAccPortIndex,
+ f3AccFlowPointIndex, f3AccFpQosPolicerIndex, f3AccFpQosPolicerStatsIndex }
+ ::= { f3AccFpQosPolicerStatsTable 1 }
+
+F3AccFpQosPolicerStatsEntry ::= SEQUENCE {
+ f3AccFpQosPolicerStatsIndex Integer32,
+ f3AccFpQosPolicerStatsIntervalType CmPmIntervalType,
+ f3AccFpQosPolicerStatsValid TruthValue,
+ f3AccFpQosPolicerStatsAction CmPmBinAction,
+ f3AccFpQosPolicerStatsFMG PerfCounter64,
+ f3AccFpQosPolicerStatsFMY PerfCounter64,
+ f3AccFpQosPolicerStatsFMRD PerfCounter64,
+ f3AccFpQosPolicerStatsBytesIn PerfCounter64,
+ f3AccFpQosPolicerStatsBytesOut PerfCounter64,
+ f3AccFpQosPolicerStatsABR PerfCounter64
+}
+
+f3AccFpQosPolicerStatsIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An integer index value used to uniquely identify
+ this QOS Policer statistics entry.
+ 1 - 15min
+ 2 - 1day
+ 3 - rollover
+ 4 - 5min"
+ ::= { f3AccFpQosPolicerStatsEntry 1 }
+
+f3AccFpQosPolicerStatsIntervalType OBJECT-TYPE
+ SYNTAX CmPmIntervalType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Interval over which Performance Monitoring data is collected."
+ ::= { f3AccFpQosPolicerStatsEntry 2 }
+
+f3AccFpQosPolicerStatsValid OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the validity of the bin."
+ ::= { f3AccFpQosPolicerStatsEntry 3 }
+
+f3AccFpQosPolicerStatsAction OBJECT-TYPE
+ SYNTAX CmPmBinAction
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Allows the Manager to clear the bin."
+ ::= { f3AccFpQosPolicerStatsEntry 4 }
+
+f3AccFpQosPolicerStatsFMG OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Frames Marked Green."
+ ::= { f3AccFpQosPolicerStatsEntry 5 }
+
+f3AccFpQosPolicerStatsFMY OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Frames Marked Yellow."
+ ::= { f3AccFpQosPolicerStatsEntry 6 }
+
+f3AccFpQosPolicerStatsFMRD OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Frames Marked Red and Discarded."
+ ::= { f3AccFpQosPolicerStatsEntry 7 }
+
+f3AccFpQosPolicerStatsBytesIn OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of bytes received by the Policer."
+ ::= { f3AccFpQosPolicerStatsEntry 8 }
+
+f3AccFpQosPolicerStatsBytesOut OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of bytes transmitted by the Policer."
+ ::= { f3AccFpQosPolicerStatsEntry 9 }
+
+f3AccFpQosPolicerStatsABR OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Average Bit Rate on the Policer."
+ ::= { f3AccFpQosPolicerStatsEntry 10 }
+
+--
+-- Access Flow Point QoS Policer History Statistics Table
+--
+
+f3AccFpQosPolicerHistoryTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF F3AccFpQosPolicerHistoryEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A collection of Acc FlowPoint QOS Policer statistics.
+ These reflect the history data."
+ ::= { f3FpmPerfObjects 17 }
+
+f3AccFpQosPolicerHistoryEntry OBJECT-TYPE
+ SYNTAX F3AccFpQosPolicerHistoryEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A conceptual row in the f3AccFpQosPolicerHistoryTable.
+ Entries exist in this table for each Acc FlowPoint QoS Policer."
+ INDEX { neIndex, shelfIndex, slotIndex, cmEthernetAccPortIndex,
+ f3AccFlowPointIndex, f3AccFpQosPolicerIndex,
+ f3AccFpQosPolicerStatsIndex, f3AccFpQosPolicerHistoryIndex }
+ ::= { f3AccFpQosPolicerHistoryTable 1 }
+
+F3AccFpQosPolicerHistoryEntry ::= SEQUENCE {
+ f3AccFpQosPolicerHistoryIndex Integer32,
+ f3AccFpQosPolicerHistoryTime DateAndTime,
+ f3AccFpQosPolicerHistoryValid TruthValue,
+ f3AccFpQosPolicerHistoryAction CmPmBinAction,
+ f3AccFpQosPolicerHistoryFMG PerfCounter64,
+ f3AccFpQosPolicerHistoryFMY PerfCounter64,
+ f3AccFpQosPolicerHistoryFMRD PerfCounter64,
+ f3AccFpQosPolicerHistoryBytesIn PerfCounter64,
+ f3AccFpQosPolicerHistoryBytesOut PerfCounter64,
+ f3AccFpQosPolicerHistoryABR PerfCounter64
+}
+
+f3AccFpQosPolicerHistoryIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An arbitrary integer index value used to uniquely identify
+ this QOS Policer history entry."
+ ::= { f3AccFpQosPolicerHistoryEntry 1 }
+
+f3AccFpQosPolicerHistoryTime OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the time of history bin creation."
+ ::= { f3AccFpQosPolicerHistoryEntry 2 }
+
+f3AccFpQosPolicerHistoryValid OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the validity of the bin."
+ ::= { f3AccFpQosPolicerHistoryEntry 3 }
+
+f3AccFpQosPolicerHistoryAction OBJECT-TYPE
+ SYNTAX CmPmBinAction
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Allows the Manager to clear the bin."
+ ::= { f3AccFpQosPolicerHistoryEntry 4 }
+
+f3AccFpQosPolicerHistoryFMG OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Frames Marked Green."
+ ::= { f3AccFpQosPolicerHistoryEntry 5 }
+
+f3AccFpQosPolicerHistoryFMY OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Frames Marked Yellow."
+ ::= { f3AccFpQosPolicerHistoryEntry 6 }
+
+f3AccFpQosPolicerHistoryFMRD OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Frames Marked Red and Discarded."
+ ::= { f3AccFpQosPolicerHistoryEntry 7 }
+
+f3AccFpQosPolicerHistoryBytesIn OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of bytes received by the Policer."
+ ::= { f3AccFpQosPolicerHistoryEntry 8 }
+
+f3AccFpQosPolicerHistoryBytesOut OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of bytes transmitted by the Policer."
+ ::= { f3AccFpQosPolicerHistoryEntry 9 }
+
+f3AccFpQosPolicerHistoryABR OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Average Bit Rate on the Policer."
+ ::= { f3AccFpQosPolicerHistoryEntry 10 }
+
+--
+-- Access Flow Point QoS Policer Threshold Table
+--
+
+f3AccFpQosPolicerThresholdTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF F3AccFpQosPolicerThresholdEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of entries that allow manageability of QOS
+ Policer Thresholds."
+ ::= { f3FpmPerfObjects 18 }
+
+f3AccFpQosPolicerThresholdEntry OBJECT-TYPE
+ SYNTAX F3AccFpQosPolicerThresholdEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A conceptual row in the f3AccFpQosPolicerThresholdTable."
+ INDEX { neIndex, shelfIndex, slotIndex, cmEthernetAccPortIndex,
+ f3AccFlowPointIndex, f3AccFpQosPolicerIndex,
+ f3AccFpQosPolicerStatsIndex, f3AccFpQosPolicerThresholdIndex }
+ ::= { f3AccFpQosPolicerThresholdTable 1 }
+
+F3AccFpQosPolicerThresholdEntry ::= SEQUENCE {
+ f3AccFpQosPolicerThresholdIndex Integer32,
+ f3AccFpQosPolicerThresholdInterval CmPmIntervalType,
+ f3AccFpQosPolicerThresholdVariable VariablePointer,
+ f3AccFpQosPolicerThresholdValueLo Unsigned32,
+ f3AccFpQosPolicerThresholdValueHi Unsigned32,
+ f3AccFpQosPolicerThresholdMonValue Counter64
+}
+
+f3AccFpQosPolicerThresholdIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An index that uniquely identifies an entry in the
+ f3AccFpQosPolicerThresholdTable."
+ ::= { f3AccFpQosPolicerThresholdEntry 1 }
+
+f3AccFpQosPolicerThresholdInterval OBJECT-TYPE
+ SYNTAX CmPmIntervalType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The interval over which monitored value is
+ sampled and compared with the specified threshold."
+ ::= { f3AccFpQosPolicerThresholdEntry 2 }
+
+f3AccFpQosPolicerThresholdVariable OBJECT-TYPE
+ SYNTAX VariablePointer
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The object identifier of the particular variable to be
+ sampled."
+ ::= { f3AccFpQosPolicerThresholdEntry 3 }
+
+f3AccFpQosPolicerThresholdValueLo OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Lower 32 bits of the threshold value."
+ ::= { f3AccFpQosPolicerThresholdEntry 4 }
+
+f3AccFpQosPolicerThresholdValueHi OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Higher 32 bits of the threshold value."
+ ::= { f3AccFpQosPolicerThresholdEntry 5 }
+
+f3AccFpQosPolicerThresholdMonValue OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Monitored value corresponding to f3AccFpQosPolicerThresholdVariable."
+ ::= { f3AccFpQosPolicerThresholdEntry 6 }
+
+--
+-- Network Flow Point QoS Policer Current Statistics Table
+--
+
+f3NetFpQosPolicerStatsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF F3NetFpQosPolicerStatsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A collection of Net FlowPoint QOS Policer statistics.
+ These reflect the current data."
+ ::= { f3FpmPerfObjects 19 }
+
+f3NetFpQosPolicerStatsEntry OBJECT-TYPE
+ SYNTAX F3NetFpQosPolicerStatsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A conceptual row in the f3NetFpQosPolicerStatsTable.
+ Entries exist in this table for each Net FlowPoint QoS Policer."
+ INDEX { neIndex, shelfIndex, slotIndex, cmEthernetNetPortIndex,
+ f3NetFlowPointIndex, f3NetFpQosPolicerIndex, f3NetFpQosPolicerStatsIndex }
+ ::= { f3NetFpQosPolicerStatsTable 1 }
+
+F3NetFpQosPolicerStatsEntry ::= SEQUENCE {
+ f3NetFpQosPolicerStatsIndex Integer32,
+ f3NetFpQosPolicerStatsIntervalType CmPmIntervalType,
+ f3NetFpQosPolicerStatsValid TruthValue,
+ f3NetFpQosPolicerStatsAction CmPmBinAction,
+ f3NetFpQosPolicerStatsFMG PerfCounter64,
+ f3NetFpQosPolicerStatsFMY PerfCounter64,
+ f3NetFpQosPolicerStatsFMRD PerfCounter64,
+ f3NetFpQosPolicerStatsBytesIn PerfCounter64,
+ f3NetFpQosPolicerStatsBytesOut PerfCounter64,
+ f3NetFpQosPolicerStatsABR PerfCounter64
+}
+
+f3NetFpQosPolicerStatsIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An integer index value used to uniquely identify
+ this QOS Policer statistics entry.
+ 1 - 15min
+ 2 - 1day
+ 3 - rollover
+ 4 - 5min"
+ ::= { f3NetFpQosPolicerStatsEntry 1 }
+
+f3NetFpQosPolicerStatsIntervalType OBJECT-TYPE
+ SYNTAX CmPmIntervalType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Interval over which Performance Monitoring data is collected."
+ ::= { f3NetFpQosPolicerStatsEntry 2 }
+
+f3NetFpQosPolicerStatsValid OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the validity of the bin."
+ ::= { f3NetFpQosPolicerStatsEntry 3 }
+
+f3NetFpQosPolicerStatsAction OBJECT-TYPE
+ SYNTAX CmPmBinAction
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Allows the Manager to clear the bin."
+ ::= { f3NetFpQosPolicerStatsEntry 4 }
+
+f3NetFpQosPolicerStatsFMG OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Frames Marked Green."
+ ::= { f3NetFpQosPolicerStatsEntry 5 }
+
+f3NetFpQosPolicerStatsFMY OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Frames Marked Yellow."
+ ::= { f3NetFpQosPolicerStatsEntry 6 }
+
+f3NetFpQosPolicerStatsFMRD OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Frames Marked Red and Discarded."
+ ::= { f3NetFpQosPolicerStatsEntry 7 }
+
+f3NetFpQosPolicerStatsBytesIn OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of bytes received by the Policer."
+ ::= { f3NetFpQosPolicerStatsEntry 8 }
+
+f3NetFpQosPolicerStatsBytesOut OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of bytes transmitted by the Policer."
+ ::= { f3NetFpQosPolicerStatsEntry 9 }
+
+f3NetFpQosPolicerStatsABR OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Average Bit Rate on the Policer."
+ ::= { f3NetFpQosPolicerStatsEntry 10 }
+
+--
+-- Network Flow Point QoS Policer History Statistics Table
+--
+
+f3NetFpQosPolicerHistoryTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF F3NetFpQosPolicerHistoryEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A collection of Net FlowPoint QOS Policer statistics.
+ These reflect the history data."
+ ::= { f3FpmPerfObjects 20 }
+
+f3NetFpQosPolicerHistoryEntry OBJECT-TYPE
+ SYNTAX F3NetFpQosPolicerHistoryEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A conceptual row in the f3NetFpQosPolicerHistoryTable.
+ Entries exist in this table for each Net FlowPoint QoS Policer."
+ INDEX { neIndex, shelfIndex, slotIndex, cmEthernetNetPortIndex,
+ f3NetFlowPointIndex, f3NetFpQosPolicerIndex,
+ f3NetFpQosPolicerStatsIndex, f3NetFpQosPolicerHistoryIndex }
+ ::= { f3NetFpQosPolicerHistoryTable 1 }
+
+F3NetFpQosPolicerHistoryEntry ::= SEQUENCE {
+ f3NetFpQosPolicerHistoryIndex Integer32,
+ f3NetFpQosPolicerHistoryTime DateAndTime,
+ f3NetFpQosPolicerHistoryValid TruthValue,
+ f3NetFpQosPolicerHistoryAction CmPmBinAction,
+ f3NetFpQosPolicerHistoryFMG PerfCounter64,
+ f3NetFpQosPolicerHistoryFMY PerfCounter64,
+ f3NetFpQosPolicerHistoryFMRD PerfCounter64,
+ f3NetFpQosPolicerHistoryBytesIn PerfCounter64,
+ f3NetFpQosPolicerHistoryBytesOut PerfCounter64,
+ f3NetFpQosPolicerHistoryABR PerfCounter64
+}
+
+f3NetFpQosPolicerHistoryIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An arbitrary integer index value used to uniquely identify
+ this QOS Policer history entry."
+ ::= { f3NetFpQosPolicerHistoryEntry 1 }
+
+f3NetFpQosPolicerHistoryTime OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the time of history bin creation."
+ ::= { f3NetFpQosPolicerHistoryEntry 2 }
+
+f3NetFpQosPolicerHistoryValid OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the validity of the bin."
+ ::= { f3NetFpQosPolicerHistoryEntry 3 }
+
+f3NetFpQosPolicerHistoryAction OBJECT-TYPE
+ SYNTAX CmPmBinAction
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Allows the Manager to clear the bin."
+ ::= { f3NetFpQosPolicerHistoryEntry 4 }
+
+f3NetFpQosPolicerHistoryFMG OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Frames Marked Green."
+ ::= { f3NetFpQosPolicerHistoryEntry 5 }
+
+f3NetFpQosPolicerHistoryFMY OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Frames Marked Yellow."
+ ::= { f3NetFpQosPolicerHistoryEntry 6 }
+
+f3NetFpQosPolicerHistoryFMRD OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Frames Marked Red and Discarded."
+ ::= { f3NetFpQosPolicerHistoryEntry 7 }
+
+f3NetFpQosPolicerHistoryBytesIn OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of bytes received by the Policer."
+ ::= { f3NetFpQosPolicerHistoryEntry 8 }
+
+f3NetFpQosPolicerHistoryBytesOut OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of bytes transmitted by the Policer."
+ ::= { f3NetFpQosPolicerHistoryEntry 9 }
+
+f3NetFpQosPolicerHistoryABR OBJECT-TYPE
+ SYNTAX PerfCounter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Average Bit Rate on the Policer."
+ ::= { f3NetFpQosPolicerHistoryEntry 10 }
+
+--
+-- Network Flow Point QoS Policer Threshold Table
+--
+
+f3NetFpQosPolicerThresholdTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF F3NetFpQosPolicerThresholdEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of entries that allow manageability of QOS
+ Policer Thresholds."
+ ::= { f3FpmPerfObjects 21 }
+
+f3NetFpQosPolicerThresholdEntry OBJECT-TYPE
+ SYNTAX F3NetFpQosPolicerThresholdEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A conceptual row in the f3NetFpQosPolicerThresholdTable."
+ INDEX { neIndex, shelfIndex, slotIndex, cmEthernetNetPortIndex,
+ f3NetFlowPointIndex, f3NetFpQosPolicerIndex,
+ f3NetFpQosPolicerStatsIndex, f3NetFpQosPolicerThresholdIndex }
+ ::= { f3NetFpQosPolicerThresholdTable 1 }
+
+F3NetFpQosPolicerThresholdEntry ::= SEQUENCE {
+ f3NetFpQosPolicerThresholdIndex Integer32,
+ f3NetFpQosPolicerThresholdInterval CmPmIntervalType,
+ f3NetFpQosPolicerThresholdVariable VariablePointer,
+ f3NetFpQosPolicerThresholdValueLo Unsigned32,
+ f3NetFpQosPolicerThresholdValueHi Unsigned32,
+ f3NetFpQosPolicerThresholdMonValue Counter64
+}
+
+f3NetFpQosPolicerThresholdIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An index that uniquely identifies an entry in the
+ f3NetFpQosPolicerThresholdTable."
+ ::= { f3NetFpQosPolicerThresholdEntry 1 }
+
+f3NetFpQosPolicerThresholdInterval OBJECT-TYPE
+ SYNTAX CmPmIntervalType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The interval over which monitored value is
+ sampled and compared with the specified threshold."
+ ::= { f3NetFpQosPolicerThresholdEntry 2 }
+
+f3NetFpQosPolicerThresholdVariable OBJECT-TYPE
+ SYNTAX VariablePointer
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The object identifier of the particular variable to be
+ sampled."
+ ::= { f3NetFpQosPolicerThresholdEntry 3 }
+
+f3NetFpQosPolicerThresholdValueLo OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Lower 32 bits of the threshold value."
+ ::= { f3NetFpQosPolicerThresholdEntry 4 }
+
+f3NetFpQosPolicerThresholdValueHi OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Higher 32 bits of the threshold value."
+ ::= { f3NetFpQosPolicerThresholdEntry 5 }
+
+f3NetFpQosPolicerThresholdMonValue OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Monitored value corresponding to f3NetFpQosPolicerThresholdVariable."
+ ::= { f3NetFpQosPolicerThresholdEntry 6 }
+
+--
+-- Notifications
+--
+
+f3AccFlowPointThresholdCrossingAlert NOTIFICATION-TYPE
+ OBJECTS {
+ f3AccFlowPointThresholdIndex,
+ f3AccFlowPointThresholdInterval,
+ f3AccFlowPointThresholdVariable,
+ f3AccFlowPointThresholdValueLo,
+ f3AccFlowPointThresholdValueHi,
+ f3AccFlowPointThresholdMonValue
+ }
+ STATUS current
+ DESCRIPTION
+ "This trap is sent each time a threshold on a PM condition
+ on an Ethernet Access Port FlowPoint is crossed."
+ ::= { f3FpmPerfNotifications 1 }
+
+f3NetFlowPointThresholdCrossingAlert NOTIFICATION-TYPE
+ OBJECTS {
+ f3NetFlowPointThresholdIndex,
+ f3NetFlowPointThresholdInterval,
+ f3NetFlowPointThresholdVariable,
+ f3NetFlowPointThresholdValueLo,
+ f3NetFlowPointThresholdValueHi,
+ f3NetFlowPointThresholdMonValue
+ }
+ STATUS current
+ DESCRIPTION
+ "This trap is sent each time a threshold on a PM condition
+ on an Ethernet Network Port FlowPoint is crossed."
+ ::= { f3FpmPerfNotifications 2 }
+
+f3MPFlowThresholdCrossingAlert NOTIFICATION-TYPE
+ OBJECTS {
+ f3MPFlowThresholdIndex,
+ f3MPFlowThresholdInterval,
+ f3MPFlowThresholdVariable,
+ f3MPFlowThresholdValueLo,
+ f3MPFlowThresholdValueHi,
+ f3MPFlowThresholdMonValue
+ }
+ STATUS current
+ DESCRIPTION
+ "This trap is sent each time a threshold on a PM condition
+ on an MP Flow is crossed."
+ ::= { f3FpmPerfNotifications 3 }
+
+f3AccFpQosShaperThresholdCrossingAlert NOTIFICATION-TYPE
+ OBJECTS {
+ f3AccFpQosShaperThresholdIndex,
+ f3AccFpQosShaperThresholdInterval,
+ f3AccFpQosShaperThresholdVariable,
+ f3AccFpQosShaperThresholdValueLo,
+ f3AccFpQosShaperThresholdValueHi,
+ f3AccFpQosShaperThresholdMonValue
+ }
+ STATUS current
+ DESCRIPTION
+ "This trap is sent each time a threshold on a PM condition
+ on an Acc FlowPoint QoS Shaper is crossed."
+ ::= { f3FpmPerfNotifications 4 }
+
+f3NetFpQosShaperThresholdCrossingAlert NOTIFICATION-TYPE
+ OBJECTS {
+ f3NetFpQosShaperThresholdIndex,
+ f3NetFpQosShaperThresholdInterval,
+ f3NetFpQosShaperThresholdVariable,
+ f3NetFpQosShaperThresholdValueLo,
+ f3NetFpQosShaperThresholdValueHi,
+ f3NetFpQosShaperThresholdMonValue
+ }
+ STATUS current
+ DESCRIPTION
+ "This trap is sent each time a threshold on a PM condition
+ on an Net FlowPoint QoS Shaper is crossed."
+ ::= { f3FpmPerfNotifications 5 }
+
+f3AccFpQosPolicerThresholdCrossingAlert NOTIFICATION-TYPE
+ OBJECTS {
+ f3AccFpQosPolicerThresholdIndex,
+ f3AccFpQosPolicerThresholdInterval,
+ f3AccFpQosPolicerThresholdVariable,
+ f3AccFpQosPolicerThresholdValueLo,
+ f3AccFpQosPolicerThresholdValueHi,
+ f3AccFpQosPolicerThresholdMonValue
+ }
+ STATUS current
+ DESCRIPTION
+ "This trap is sent each time a threshold on a PM condition
+ on an Acc FlowPoint QoS Policer is crossed."
+ ::= { f3FpmPerfNotifications 6 }
+
+f3NetFpQosPolicerThresholdCrossingAlert NOTIFICATION-TYPE
+ OBJECTS {
+ f3NetFpQosPolicerThresholdIndex,
+ f3NetFpQosPolicerThresholdInterval,
+ f3NetFpQosPolicerThresholdVariable,
+ f3NetFpQosPolicerThresholdValueLo,
+ f3NetFpQosPolicerThresholdValueHi,
+ f3NetFpQosPolicerThresholdMonValue
+ }
+ STATUS current
+ DESCRIPTION
+ "This trap is sent each time a threshold on a PM condition
+ on an Net FlowPoint QoS Policer is crossed."
+ ::= { f3FpmPerfNotifications 7 }
+
+--
+-- Conformance
+--
+
+f3FpmCompliances OBJECT IDENTIFIER ::= {f3FpmConformance 1}
+f3FpmGroups OBJECT IDENTIFIER ::= {f3FpmConformance 2}
+
+f3FpmCompliance MODULE-COMPLIANCE
+ STATUS current
+ DESCRIPTION
+ "Describes the requirements for conformance to the F3-FPM-MIB compilance."
+ MODULE -- this module
+ MANDATORY-GROUPS {
+ f3AccFlowPointGroup,
+ f3AccFpQosShaperGroup,
+ f3AccFpQosPolicerGroup,
+ f3MPFlowExtGroup,
+ f3AccFlowPointCpdV2Group,
+ f3AccFlowPointLearningConfigGroup,
+ f3NetFlowPointGroup,
+ f3NetFpQosShaperGroup,
+ f3NetFpQosPolicerGroup,
+ f3NetFlowPointCpdV2Group,
+ f3NetFlowPointLearningConfigGroup,
+ f3AccFlowPointPerfGroup,
+ f3NetFlowPointPerfGroup,
+ f3MPFlowPerfGroup,
+ f3AccFpQosShaperPerfGroup,
+ f3NetFpQosShaperPerfGroup,
+ f3AccFpQosPolicerPerfGroup,
+ f3NetFpQosPolicerPerfGroup,
+ f3FpmPerfNotifGroup
+ }
+ ::= { f3FpmCompliances 1 }
+
+f3AccFlowPointGroup OBJECT-GROUP
+ OBJECTS {
+ f3AccFlowPointAlias,
+ f3AccFlowPointAdminState,
+ f3AccFlowPointOperationalState,
+ f3AccFlowPointSecondaryState,
+ f3AccFlowPointAssociatedFlowId,
+ f3AccFlowPointIngressMultiCOSEnabled,
+ f3AccFlowPointIngressCOS,
+ f3AccFlowPointEgressShapingType,
+ f3AccFlowPointIngressVlanMemberList,
+ f3AccFlowPointVlanMemberAction,
+ f3AccFlowPointVlanMemberActionVlan,
+ f3AccFlowPointIngressUntaggedFrameEnabled,
+ f3AccFlowPointCTagControl,
+ f3AccFlowPointCTagVlanId,
+ f3AccFlowPointCTagVlanPriority,
+ f3AccFlowPointSTagControl,
+ f3AccFlowPointSTagVlanId,
+ f3AccFlowPointSTagVlanPriority,
+ f3AccFlowPointEgressOuterTagPrioMapEnabled,
+ f3AccFlowPointEgressInnerTagPrioMapEnabled,
+ f3AccFlowPointSESFramesLossThresholdRatio,
+ f3AccFlowPointDefaultMemberEnabled,
+ f3AccFlowPointMcastRateLimitEnabled,
+ f3AccFlowPointMcastRateLimitSpeedLo,
+ f3AccFlowPointMcastRateLimitSpeedHi,
+ f3AccFlowPointBcastRateLimitEnabled,
+ f3AccFlowPointBcastRateLimitSpeedLo,
+ f3AccFlowPointBcastRateLimitSpeedHi,
+ f3AccFlowPointCombinedRateLimitEnabled,
+ f3AccFlowPointCombinedRateLimitSpeedLo,
+ f3AccFlowPointCombinedRateLimitSpeedHi,
+ f3AccFlowPointSplitHorizonGroupOID,
+ f3AccFlowPointLoopAvoidance,
+ f3AccFlowPointHierarchicalCOSEnabled,
+ f3AccFlowPointMaximumBWLo,
+ f3AccFlowPointMaximumBWHi,
+ f3AccFlowPointGuaranteedBWLo,
+ f3AccFlowPointGuaranteedBWHi,
+ f3AccFlowPointAutoBandwidthConfigEnabled,
+ f3AccFlowPointAutoCIRPercentage,
+ f3AccFlowPointFrameFwdEnabled,
+ f3AccFlowPointStorageType,
+ f3AccFlowPointRowStatus,
+ f3AccFlowPointUsePortPrioMapProfile,
+ f3AccFlowPointRefPrioMapProfile,
+ f3AccFlowpointRefConnectGuardFlowObject,
+ f3AccFlowpointSecureBlockingControl,
+ f3AccFlowpointSecureState
+
+ }
+ STATUS current
+ DESCRIPTION
+ "A collection of Access Flow Point objects."
+ ::= { f3FpmGroups 1 }
+
+f3AccFpQosShaperGroup OBJECT-GROUP
+ OBJECTS {
+ f3AccFpQosShaperIndex,
+ f3AccFpQosShaperAdminState,
+ f3AccFpQosShaperOperationalState,
+ f3AccFpQosShaperSecondaryState,
+ f3AccFpQosShaperCIRLo,
+ f3AccFpQosShaperCIRHi,
+ f3AccFpQosShaperCBS,
+ f3AccFpQosShaperEIRLo,
+ f3AccFpQosShaperEIRHi,
+ f3AccFpQosShaperEBS,
+ f3AccFpQosShaperBufferSize,
+ f3AccFpQosShaperCOS,
+ f3AccFpQosShaperStorageType,
+ f3AccFpQosShaperRowStatus
+ }
+ STATUS current
+ DESCRIPTION
+ "A collection of Access Flow Point QoS Shaper objects."
+ ::= { f3FpmGroups 2 }
+
+f3AccFpQosPolicerGroup OBJECT-GROUP
+ OBJECTS {
+ f3AccFpQosPolicerAdminState,
+ f3AccFpQosPolicerOperationalState,
+ f3AccFpQosPolicerSecondaryState,
+ f3AccFpQosPolicerCIRLo,
+ f3AccFpQosPolicerCIRHi,
+ f3AccFpQosPolicerEIRLo,
+ f3AccFpQosPolicerEIRHi,
+ f3AccFpQosPolicerCBS,
+ f3AccFpQosPolicerEBS,
+ f3AccFpQosPolicerAlgorithm,
+ f3AccFpQosPolicerColorMode,
+ f3AccFpQosPolicerCouplingFlag,
+ f3AccFpQosPolicerStorageType,
+ f3AccFpQosPolicerRowStatus
+ }
+ STATUS current
+ DESCRIPTION
+ "A collection of Access Flow Point QoS Policer objects."
+ ::= { f3FpmGroups 3 }
+
+f3MPFlowExtGroup OBJECT-GROUP
+ OBJECTS {
+ f3MPFlowExtMaxFwdEntries,
+ f3MPFlowRefConnectGuardFlowObject,
+ f3MPFlowSecureState
+ }
+ STATUS current
+ DESCRIPTION
+ "A collection of MP Flow objects."
+ ::= { f3FpmGroups 4 }
+
+f3AccFlowPointCpdV2Group OBJECT-GROUP
+ OBJECTS {
+ f3AccFlowPointCpdV2IslDispType,
+ f3AccFlowPointCpdV2PagpDispType,
+ f3AccFlowPointCpdV2UdldDispType,
+ f3AccFlowPointCpdV2CdpDispType,
+ f3AccFlowPointCpdV2VtpDispType,
+ f3AccFlowPointCpdV2DtpDispType,
+ f3AccFlowPointCpdV2PvstpPlusDispType,
+ f3AccFlowPointCpdV2UplinkFastDispType,
+ f3AccFlowPointCpdV2VlanBridgeDispType,
+ f3AccFlowPointCpdV2L2PTDispType,
+ f3AccFlowPointCpdV2BPDUDispType,
+ f3AccFlowPointCpdV2PauseDispType,
+ f3AccFlowPointCpdV2LACPDispType,
+ f3AccFlowPointCpdV2LACPMarkerDispType,
+ f3AccFlowPointCpdV2EfmOamDispType,
+ f3AccFlowPointCpdV2SSMDispType,
+ f3AccFlowPointCpdV2PortAuthenDispType,
+ f3AccFlowPointCpdV2LANBridgesDispType,
+ f3AccFlowPointCpdV2GMRPDispType,
+ f3AccFlowPointCpdV2GVRPDispType,
+ f3AccFlowPointCpdV2GARPDispType,
+ f3AccFlowPointCpdV2ActiveControlProtocols,
+ f3AccFlowPointCpdV2ELMIDispType,
+ f3AccFlowPointCpdV2Mac00DispType,
+ f3AccFlowPointCpdV2Mac01DispType,
+ f3AccFlowPointCpdV2Mac02DispType,
+ f3AccFlowPointCpdV2Mac03DispType,
+ f3AccFlowPointCpdV2Mac04DispType,
+ f3AccFlowPointCpdV2Mac05DispType,
+ f3AccFlowPointCpdV2Mac06DispType,
+ f3AccFlowPointCpdV2Mac07DispType,
+ f3AccFlowPointCpdV2Mac08DispType,
+ f3AccFlowPointCpdV2Mac09DispType,
+ f3AccFlowPointCpdV2Mac0ADispType,
+ f3AccFlowPointCpdV2Mac0BDispType,
+ f3AccFlowPointCpdV2Mac0CDispType,
+ f3AccFlowPointCpdV2Mac0DDispType,
+ f3AccFlowPointCpdV2Mac0EDispType,
+ f3AccFlowPointCpdV2Mac0FDispType,
+ f3AccFlowPointCpdV2NearestLLDPDispType,
+ f3AccFlowPointCpdV2NonTpmrLLDPDispType,
+ f3AccFlowPointCpdV2CustomerLLDPDispType
+ }
+ STATUS current
+ DESCRIPTION
+ "A collection of Access Flow Point CDPV2 objects."
+ ::= { f3FpmGroups 5 }
+
+f3AccFlowPointLearningConfigGroup OBJECT-GROUP
+ OBJECTS {
+ f3AccFlowPointLearningConfigLearningEnabled,
+ f3AccFlowPointLearningConfigMaxFwdEntries,
+ f3AccFlowPointLearningConfigProtectLearningCtrl,
+ f3AccFlowPointLearningConfigAction
+ }
+ STATUS current
+ DESCRIPTION
+ "A collection of Access Flowpoint Learning Config objects."
+ ::= { f3FpmGroups 6 }
+
+f3NetFlowPointGroup OBJECT-GROUP
+ OBJECTS {
+ f3NetFlowPointAlias,
+ f3NetFlowPointAdminState,
+ f3NetFlowPointOperationalState,
+ f3NetFlowPointSecondaryState,
+ f3NetFlowPointAssociatedFlowId,
+ f3NetFlowPointIngressMultiCOSEnabled,
+ f3NetFlowPointIngressCOS,
+ f3NetFlowPointEgressShapingType,
+ f3NetFlowPointIngressVlanMemberList,
+ f3NetFlowPointVlanMemberAction,
+ f3NetFlowPointVlanMemberActionVlan,
+ f3NetFlowPointIngressUntaggedFrameEnabled,
+ f3NetFlowPointCTagControl,
+ f3NetFlowPointCTagVlanId,
+ f3NetFlowPointCTagVlanPriority,
+ f3NetFlowPointSTagControl,
+ f3NetFlowPointSTagVlanId,
+ f3NetFlowPointSTagVlanPriority,
+ f3NetFlowPointEgressOuterTagPrioMapEnabled,
+ f3NetFlowPointEgressInnerTagPrioMapEnabled,
+ f3NetFlowPointSESFramesLossThresholdRatio,
+ f3NetFlowPointDefaultMemberEnabled,
+ f3NetFlowPointMcastRateLimitEnabled,
+ f3NetFlowPointMcastRateLimitSpeedLo,
+ f3NetFlowPointMcastRateLimitSpeedHi,
+ f3NetFlowPointBcastRateLimitEnabled,
+ f3NetFlowPointBcastRateLimitSpeedLo,
+ f3NetFlowPointBcastRateLimitSpeedHi,
+ f3NetFlowPointCombinedRateLimitEnabled,
+ f3NetFlowPointCombinedRateLimitSpeedLo,
+ f3NetFlowPointCombinedRateLimitSpeedHi,
+ f3NetFlowPointSplitHorizonGroupOID,
+ f3NetFlowPointLoopAvoidance,
+ f3NetFlowPointHierarchicalCOSEnabled,
+ f3NetFlowPointMaximumBWLo,
+ f3NetFlowPointMaximumBWHi,
+ f3NetFlowPointGuaranteedBWLo,
+ f3NetFlowPointGuaranteedBWHi,
+ f3NetFlowPointAutoBandwidthConfigEnabled,
+ f3NetFlowPointAutoCIRPercentage,
+ f3NetFlowPointFrameFwdEnabled,
+ f3NetFlowPointStorageType,
+ f3NetFlowPointRowStatus,
+ f3NetFlowPointUsePortPrioMapProfile,
+ f3NetFlowPointRefPrioMapProfile,
+ f3NetFlowpointRefConnectGuardFlowObject,
+ f3NetFlowpointSecureBlockingControl,
+ f3NetFlowpointSecureState
+ }
+ STATUS current
+ DESCRIPTION
+ "A collection of Network Flow Point objects."
+ ::= { f3FpmGroups 7 }
+
+f3NetFpQosShaperGroup OBJECT-GROUP
+ OBJECTS {
+ f3NetFpQosShaperIndex,
+ f3NetFpQosShaperAdminState,
+ f3NetFpQosShaperOperationalState,
+ f3NetFpQosShaperSecondaryState,
+ f3NetFpQosShaperCIRLo,
+ f3NetFpQosShaperCIRHi,
+ f3NetFpQosShaperCBS,
+ f3NetFpQosShaperEIRLo,
+ f3NetFpQosShaperEIRHi,
+ f3NetFpQosShaperEBS,
+ f3NetFpQosShaperBufferSize,
+ f3NetFpQosShaperCOS,
+ f3NetFpQosShaperStorageType,
+ f3NetFpQosShaperRowStatus
+ }
+ STATUS current
+ DESCRIPTION
+ "A collection of Network Flow Point QoS Shaper objects."
+ ::= { f3FpmGroups 8 }
+
+f3NetFpQosPolicerGroup OBJECT-GROUP
+ OBJECTS {
+ f3NetFpQosPolicerAdminState,
+ f3NetFpQosPolicerOperationalState,
+ f3NetFpQosPolicerSecondaryState,
+ f3NetFpQosPolicerCIRLo,
+ f3NetFpQosPolicerCIRHi,
+ f3NetFpQosPolicerEIRLo,
+ f3NetFpQosPolicerEIRHi,
+ f3NetFpQosPolicerCBS,
+ f3NetFpQosPolicerEBS,
+ f3NetFpQosPolicerAlgorithm,
+ f3NetFpQosPolicerColorMode,
+ f3NetFpQosPolicerCouplingFlag,
+ f3NetFpQosPolicerStorageType,
+ f3NetFpQosPolicerRowStatus
+ }
+ STATUS current
+ DESCRIPTION
+ "A collection of Network Flow Point QoS Policer objects."
+ ::= { f3FpmGroups 9 }
+
+f3NetFlowPointCpdV2Group OBJECT-GROUP
+ OBJECTS {
+ f3NetFlowPointCpdV2IslDispType,
+ f3NetFlowPointCpdV2PagpDispType,
+ f3NetFlowPointCpdV2UdldDispType,
+ f3NetFlowPointCpdV2CdpDispType,
+ f3NetFlowPointCpdV2VtpDispType,
+ f3NetFlowPointCpdV2DtpDispType,
+ f3NetFlowPointCpdV2PvstpPlusDispType,
+ f3NetFlowPointCpdV2UplinkFastDispType,
+ f3NetFlowPointCpdV2VlanBridgeDispType,
+ f3NetFlowPointCpdV2L2PTDispType,
+ f3NetFlowPointCpdV2BPDUDispType,
+ f3NetFlowPointCpdV2PauseDispType,
+ f3NetFlowPointCpdV2LACPDispType,
+ f3NetFlowPointCpdV2LACPMarkerDispType,
+ f3NetFlowPointCpdV2EfmOamDispType,
+ f3NetFlowPointCpdV2SSMDispType,
+ f3NetFlowPointCpdV2PortAuthenDispType,
+ f3NetFlowPointCpdV2LANBridgesDispType,
+ f3NetFlowPointCpdV2GMRPDispType,
+ f3NetFlowPointCpdV2GVRPDispType,
+ f3NetFlowPointCpdV2GARPDispType,
+ f3NetFlowPointCpdV2ActiveControlProtocols,
+ f3NetFlowPointCpdV2ELMIDispType,
+ f3NetFlowPointCpdV2Mac00DispType,
+ f3NetFlowPointCpdV2Mac01DispType,
+ f3NetFlowPointCpdV2Mac02DispType,
+ f3NetFlowPointCpdV2Mac03DispType,
+ f3NetFlowPointCpdV2Mac04DispType,
+ f3NetFlowPointCpdV2Mac05DispType,
+ f3NetFlowPointCpdV2Mac06DispType,
+ f3NetFlowPointCpdV2Mac07DispType,
+ f3NetFlowPointCpdV2Mac08DispType,
+ f3NetFlowPointCpdV2Mac09DispType,
+ f3NetFlowPointCpdV2Mac0ADispType,
+ f3NetFlowPointCpdV2Mac0BDispType,
+ f3NetFlowPointCpdV2Mac0CDispType,
+ f3NetFlowPointCpdV2Mac0DDispType,
+ f3NetFlowPointCpdV2Mac0EDispType,
+ f3NetFlowPointCpdV2Mac0FDispType,
+ f3NetFlowPointCpdV2NearestLLDPDispType,
+ f3NetFlowPointCpdV2NonTpmrLLDPDispType,
+ f3NetFlowPointCpdV2CustomerLLDPDispType
+ }
+ STATUS current
+ DESCRIPTION
+ "A collection of Network Flow Point CDPV2 objects."
+ ::= { f3FpmGroups 10 }
+
+f3NetFlowPointLearningConfigGroup OBJECT-GROUP
+ OBJECTS {
+ f3NetFlowPointLearningConfigLearningEnabled,
+ f3NetFlowPointLearningConfigMaxFwdEntries,
+ f3NetFlowPointLearningConfigProtectLearningCtrl,
+ f3NetFlowPointLearningConfigAction
+ }
+ STATUS current
+ DESCRIPTION
+ "A collection of Network Flowpoint Learning Config objects."
+ ::= { f3FpmGroups 11 }
+
+f3AccFlowPointPerfGroup OBJECT-GROUP
+ OBJECTS {
+ f3AccFlowPointStatsIndex,
+ f3AccFlowPointStatsIntervalType,
+ f3AccFlowPointStatsValid,
+ f3AccFlowPointStatsAction,
+ f3AccFlowPointStatsL2CPFD,
+ f3AccFlowPointStatsABRRx,
+ f3AccFlowPointStatsABRRLRx,
+ f3AccFlowPointStatsUAS,
+ f3AccFlowPointStatsSES,
+ f3AccFlowPointStatsFMG,
+ f3AccFlowPointStatsFMY,
+ f3AccFlowPointStatsFMRD,
+ f3AccFlowPointStatsFTD,
+ f3AccFlowPointStatsBytesIn,
+ f3AccFlowPointStatsBytesOut,
+ f3AccFlowPointStatsIBRMax,
+ f3AccFlowPointStatsIBRRlMax,
+ f3AccFlowPointStatsIBRMin,
+ f3AccFlowPointStatsIBRRlMin,
+ f3AccFlowPointStatsIBR,
+ f3AccFlowPointStatsIBRRl,
+ f3AccFlowPointStatsFBCD,
+ f3AccFlowPointStatsFMCD,
+ f3AccFlowPointStatsFdRxFb,
+ f3AccFlowPointStatsFdTxFb,
+ f3AccFlowPointStatsFdicd,
+ f3AccFlowPointStatsNumLearnTableFlushes,
+ f3AccFlowPointHistoryIndex,
+ f3AccFlowPointHistoryTime,
+ f3AccFlowPointHistoryValid,
+ f3AccFlowPointHistoryAction,
+ f3AccFlowPointHistoryL2CPFD,
+ f3AccFlowPointHistoryABRRx,
+ f3AccFlowPointHistoryABRRLRx,
+ f3AccFlowPointHistoryUAS,
+ f3AccFlowPointHistorySES,
+ f3AccFlowPointHistoryFMG,
+ f3AccFlowPointHistoryFMY,
+ f3AccFlowPointHistoryFMRD,
+ f3AccFlowPointHistoryFTD,
+ f3AccFlowPointHistoryBytesIn,
+ f3AccFlowPointHistoryBytesOut,
+ f3AccFlowPointHistoryIBRMax,
+ f3AccFlowPointHistoryIBRRlMax,
+ f3AccFlowPointHistoryIBRMin,
+ f3AccFlowPointHistoryIBRRlMin,
+ f3AccFlowPointHistoryIBR,
+ f3AccFlowPointHistoryIBRRl,
+ f3AccFlowPointHistoryFBCD,
+ f3AccFlowPointHistoryFMCD,
+ f3AccFlowPointHistoryFdRxFb,
+ f3AccFlowPointHistoryFdTxFb,
+ f3AccFlowPointHistoryFdicd,
+ f3AccFlowPointHistoryNumLearnTableFlushes,
+ f3AccFlowPointThresholdIndex,
+ f3AccFlowPointThresholdInterval,
+ f3AccFlowPointThresholdVariable,
+ f3AccFlowPointThresholdValueLo,
+ f3AccFlowPointThresholdValueHi,
+ f3AccFlowPointThresholdMonValue
+ }
+ STATUS current
+ DESCRIPTION
+ "A collection of Access Flowpoint Performance objects."
+ ::= { f3FpmGroups 12 }
+
+f3NetFlowPointPerfGroup OBJECT-GROUP
+ OBJECTS {
+ f3NetFlowPointStatsIndex,
+ f3NetFlowPointStatsIntervalType,
+ f3NetFlowPointStatsValid,
+ f3NetFlowPointStatsAction,
+ f3NetFlowPointStatsL2CPFD,
+ f3NetFlowPointStatsABRRx,
+ f3NetFlowPointStatsABRRLRx,
+ f3NetFlowPointStatsUAS,
+ f3NetFlowPointStatsSES,
+ f3NetFlowPointStatsFMG,
+ f3NetFlowPointStatsFMY,
+ f3NetFlowPointStatsFMRD,
+ f3NetFlowPointStatsFTD,
+ f3NetFlowPointStatsBytesIn,
+ f3NetFlowPointStatsBytesOut,
+ f3NetFlowPointStatsIBRMax,
+ f3NetFlowPointStatsIBRRlMax,
+ f3NetFlowPointStatsIBRMin,
+ f3NetFlowPointStatsIBRRlMin,
+ f3NetFlowPointStatsIBR,
+ f3NetFlowPointStatsIBRRl,
+ f3NetFlowPointStatsFBCD,
+ f3NetFlowPointStatsFMCD,
+ f3NetFlowPointStatsFdRxFb,
+ f3NetFlowPointStatsFdTxFb,
+ f3NetFlowPointStatsFdicd,
+ f3NetFlowPointStatsNumLearnTableFlushes,
+ f3NetFlowPointHistoryIndex,
+ f3NetFlowPointHistoryTime,
+ f3NetFlowPointHistoryValid,
+ f3NetFlowPointHistoryAction,
+ f3NetFlowPointHistoryL2CPFD,
+ f3NetFlowPointHistoryABRRx,
+ f3NetFlowPointHistoryABRRLRx,
+ f3NetFlowPointHistoryUAS,
+ f3NetFlowPointHistorySES,
+ f3NetFlowPointHistoryFMG,
+ f3NetFlowPointHistoryFMY,
+ f3NetFlowPointHistoryFMRD,
+ f3NetFlowPointHistoryFTD,
+ f3NetFlowPointHistoryBytesIn,
+ f3NetFlowPointHistoryBytesOut,
+ f3NetFlowPointHistoryIBRMax,
+ f3NetFlowPointHistoryIBRRlMax,
+ f3NetFlowPointHistoryIBRMin,
+ f3NetFlowPointHistoryIBRRlMin,
+ f3NetFlowPointHistoryIBR,
+ f3NetFlowPointHistoryIBRRl,
+ f3NetFlowPointHistoryFBCD,
+ f3NetFlowPointHistoryFMCD,
+ f3NetFlowPointHistoryFdRxFb,
+ f3NetFlowPointHistoryFdTxFb,
+ f3NetFlowPointHistoryFdicd,
+ f3NetFlowPointHistoryNumLearnTableFlushes,
+ f3NetFlowPointThresholdIndex,
+ f3NetFlowPointThresholdInterval,
+ f3NetFlowPointThresholdVariable,
+ f3NetFlowPointThresholdValueLo,
+ f3NetFlowPointThresholdValueHi,
+ f3NetFlowPointThresholdMonValue
+ }
+ STATUS current
+ DESCRIPTION
+ "A collection of Network Flowpoint Performance objects."
+ ::= { f3FpmGroups 13 }
+
+f3MPFlowPerfGroup OBJECT-GROUP
+ OBJECTS {
+ f3MPFlowStatsIndex,
+ f3MPFlowStatsIntervalType,
+ f3MPFlowStatsValid,
+ f3MPFlowStatsAction,
+ f3MPFlowStatsFDStaticBlock,
+ f3MPFlowStatsFDHairPin,
+ f3MPFlowStatsMacTableDiscards,
+ f3MPFlowStatsFDProtLearn,
+ f3MPFlowHistoryIndex,
+ f3MPFlowHistoryTime,
+ f3MPFlowHistoryValid,
+ f3MPFlowHistoryAction,
+ f3MPFlowHistoryFDStaticBlock,
+ f3MPFlowHistoryFDHairPin,
+ f3MPFlowHistoryMacTableDiscards,
+ f3MPFlowHistoryFDProtLearn,
+ f3MPFlowThresholdIndex,
+ f3MPFlowThresholdInterval,
+ f3MPFlowThresholdVariable,
+ f3MPFlowThresholdValueLo,
+ f3MPFlowThresholdValueHi,
+ f3MPFlowThresholdMonValue
+ }
+ STATUS current
+ DESCRIPTION
+ "A collection of MP Flow Performance objects."
+ ::= { f3FpmGroups 14 }
+
+f3AccFpQosShaperPerfGroup OBJECT-GROUP
+ OBJECTS {
+ f3AccFpQosShaperStatsIndex,
+ f3AccFpQosShaperStatsIntervalType,
+ f3AccFpQosShaperStatsValid,
+ f3AccFpQosShaperStatsAction,
+ f3AccFpQosShaperStatsBT,
+ f3AccFpQosShaperStatsBTD,
+ f3AccFpQosShaperStatsFD,
+ f3AccFpQosShaperStatsFTD,
+ f3AccFpQosShaperStatsABRRL,
+ f3AccFpQosShaperStatsBREDD,
+ f3AccFpQosShaperStatsFREDD,
+ f3AccFpQosShaperHistoryIndex,
+ f3AccFpQosShaperHistoryTime,
+ f3AccFpQosShaperHistoryValid,
+ f3AccFpQosShaperHistoryAction,
+ f3AccFpQosShaperHistoryBT,
+ f3AccFpQosShaperHistoryBTD,
+ f3AccFpQosShaperHistoryFD,
+ f3AccFpQosShaperHistoryFTD,
+ f3AccFpQosShaperHistoryABRRL,
+ f3AccFpQosShaperHistoryBREDD,
+ f3AccFpQosShaperHistoryFREDD,
+ f3AccFpQosShaperThresholdIndex,
+ f3AccFpQosShaperThresholdInterval,
+ f3AccFpQosShaperThresholdVariable,
+ f3AccFpQosShaperThresholdValueLo,
+ f3AccFpQosShaperThresholdValueHi,
+ f3AccFpQosShaperThresholdMonValue
+ }
+ STATUS current
+ DESCRIPTION
+ "A collection of Acc FlowPoint QoS Shaper Performance objects."
+ ::= { f3FpmGroups 15 }
+
+f3NetFpQosShaperPerfGroup OBJECT-GROUP
+ OBJECTS {
+ f3NetFpQosShaperStatsIndex,
+ f3NetFpQosShaperStatsIntervalType,
+ f3NetFpQosShaperStatsValid,
+ f3NetFpQosShaperStatsAction,
+ f3NetFpQosShaperStatsBT,
+ f3NetFpQosShaperStatsBTD,
+ f3NetFpQosShaperStatsFD,
+ f3NetFpQosShaperStatsFTD,
+ f3NetFpQosShaperStatsABRRL,
+ f3NetFpQosShaperStatsBREDD,
+ f3NetFpQosShaperStatsFREDD,
+ f3NetFpQosShaperHistoryIndex,
+ f3NetFpQosShaperHistoryTime,
+ f3NetFpQosShaperHistoryValid,
+ f3NetFpQosShaperHistoryAction,
+ f3NetFpQosShaperHistoryBT,
+ f3NetFpQosShaperHistoryBTD,
+ f3NetFpQosShaperHistoryFD,
+ f3NetFpQosShaperHistoryFTD,
+ f3NetFpQosShaperHistoryABRRL,
+ f3NetFpQosShaperHistoryBREDD,
+ f3NetFpQosShaperHistoryFREDD,
+ f3NetFpQosShaperThresholdIndex,
+ f3NetFpQosShaperThresholdInterval,
+ f3NetFpQosShaperThresholdVariable,
+ f3NetFpQosShaperThresholdValueLo,
+ f3NetFpQosShaperThresholdValueHi,
+ f3NetFpQosShaperThresholdMonValue
+ }
+ STATUS current
+ DESCRIPTION
+ "A collection of Net FlowPoint QoS Shaper Performance objects."
+ ::= { f3FpmGroups 16 }
+
+f3AccFpQosPolicerPerfGroup OBJECT-GROUP
+ OBJECTS {
+ f3AccFpQosPolicerStatsIndex,
+ f3AccFpQosPolicerStatsIntervalType,
+ f3AccFpQosPolicerStatsValid,
+ f3AccFpQosPolicerStatsAction,
+ f3AccFpQosPolicerStatsFMG,
+ f3AccFpQosPolicerStatsFMY,
+ f3AccFpQosPolicerStatsFMRD,
+ f3AccFpQosPolicerStatsBytesIn,
+ f3AccFpQosPolicerStatsBytesOut,
+ f3AccFpQosPolicerStatsABR,
+ f3AccFpQosPolicerHistoryIndex,
+ f3AccFpQosPolicerHistoryTime,
+ f3AccFpQosPolicerHistoryValid,
+ f3AccFpQosPolicerHistoryAction,
+ f3AccFpQosPolicerHistoryFMG,
+ f3AccFpQosPolicerHistoryFMY,
+ f3AccFpQosPolicerHistoryFMRD,
+ f3AccFpQosPolicerHistoryBytesIn,
+ f3AccFpQosPolicerHistoryBytesOut,
+ f3AccFpQosPolicerHistoryABR,
+ f3AccFpQosPolicerThresholdIndex,
+ f3AccFpQosPolicerThresholdInterval,
+ f3AccFpQosPolicerThresholdVariable,
+ f3AccFpQosPolicerThresholdValueLo,
+ f3AccFpQosPolicerThresholdValueHi,
+ f3AccFpQosPolicerThresholdMonValue
+ }
+ STATUS current
+ DESCRIPTION
+ "A collection of Acc FlowPoint QoS Policer Performance objects."
+ ::= { f3FpmGroups 17 }
+
+f3NetFpQosPolicerPerfGroup OBJECT-GROUP
+ OBJECTS {
+ f3NetFpQosPolicerStatsIndex,
+ f3NetFpQosPolicerStatsIntervalType,
+ f3NetFpQosPolicerStatsValid,
+ f3NetFpQosPolicerStatsAction,
+ f3NetFpQosPolicerStatsFMG,
+ f3NetFpQosPolicerStatsFMY,
+ f3NetFpQosPolicerStatsFMRD,
+ f3NetFpQosPolicerStatsBytesIn,
+ f3NetFpQosPolicerStatsBytesOut,
+ f3NetFpQosPolicerStatsABR,
+ f3NetFpQosPolicerHistoryIndex,
+ f3NetFpQosPolicerHistoryTime,
+ f3NetFpQosPolicerHistoryValid,
+ f3NetFpQosPolicerHistoryAction,
+ f3NetFpQosPolicerHistoryFMG,
+ f3NetFpQosPolicerHistoryFMY,
+ f3NetFpQosPolicerHistoryFMRD,
+ f3NetFpQosPolicerHistoryBytesIn,
+ f3NetFpQosPolicerHistoryBytesOut,
+ f3NetFpQosPolicerHistoryABR,
+ f3NetFpQosPolicerThresholdIndex,
+ f3NetFpQosPolicerThresholdInterval,
+ f3NetFpQosPolicerThresholdVariable,
+ f3NetFpQosPolicerThresholdValueLo,
+ f3NetFpQosPolicerThresholdValueHi,
+ f3NetFpQosPolicerThresholdMonValue
+ }
+ STATUS current
+ DESCRIPTION
+ "A collection of Net FlowPoint QoS Policer Performance objects."
+ ::= { f3FpmGroups 18 }
+
+f3FpmPerfNotifGroup NOTIFICATION-GROUP
+ NOTIFICATIONS {
+ f3AccFlowPointThresholdCrossingAlert,
+ f3NetFlowPointThresholdCrossingAlert,
+ f3MPFlowThresholdCrossingAlert,
+ f3AccFpQosShaperThresholdCrossingAlert,
+ f3NetFpQosShaperThresholdCrossingAlert,
+ f3AccFpQosPolicerThresholdCrossingAlert,
+ f3NetFpQosPolicerThresholdCrossingAlert
+ }
+ STATUS current
+ DESCRIPTION
+ "A collection of notifications related to FSP150CC
+ Threshold Crossing Alerts."
+ ::= { f3FpmGroups 19 }
+
+END