diff options
Diffstat (limited to 'MIBS/arista/ARISTA-ENTITY-SENSOR-MIB')
| -rw-r--r-- | MIBS/arista/ARISTA-ENTITY-SENSOR-MIB | 199 |
1 files changed, 199 insertions, 0 deletions
diff --git a/MIBS/arista/ARISTA-ENTITY-SENSOR-MIB b/MIBS/arista/ARISTA-ENTITY-SENSOR-MIB new file mode 100644 index 0000000..d41c9f3 --- /dev/null +++ b/MIBS/arista/ARISTA-ENTITY-SENSOR-MIB @@ -0,0 +1,199 @@ +ARISTA-ENTITY-SENSOR-MIB DEFINITIONS ::= BEGIN + +IMPORTS + MODULE-IDENTITY, OBJECT-TYPE, + NOTIFICATION-TYPE FROM SNMPv2-SMI + MODULE-COMPLIANCE, OBJECT-GROUP, + NOTIFICATION-GROUP FROM SNMPv2-CONF + entPhysicalIndex, entPhysicalDescr FROM ENTITY-MIB + entStateAlarm FROM ENTITY-STATE-MIB + EntitySensorValue, entPhySensorValue + FROM ENTITY-SENSOR-MIB + SnmpAdminString FROM SNMP-FRAMEWORK-MIB + aristaMibs FROM ARISTA-SMI-MIB; + + +aristaEntSensorMIB MODULE-IDENTITY + LAST-UPDATED "201408150000Z" + ORGANIZATION "Arista Networks, Inc." + CONTACT-INFO + "Arista Networks, Inc. + + Postal: 5453 Great America Parkway + Santa Clara, CA 95054 + + Tel: +1 408 547-5500 + + E-mail: snmp@arista.com" + DESCRIPTION + "This MIB module augments the entPhySensorTable of + ENTITY-SENSOR-MIB to provide threshold information for + various sensors in the system. For example, a given device + may have several voltage sensors as well as temperature + sensors each with appropriate threshold support to help + NMS systems detect and alert appropriately. + + In addition, on systems where it is supported, if the + sensor value crosses the supported threshold value the system + can generate appropriate notification as well." + REVISION "201408150000Z" + DESCRIPTION "Updated postal and e-mail addresses." + REVISION "201305090950Z" + DESCRIPTION "Initial version of this MIB module." + ::= { aristaMibs 12 } + +-- Textual Conventions -- + + aristaEntSensorMibNotifications OBJECT IDENTIFIER + ::= { aristaEntSensorMIB 0 } + +aristaEntSensorMibObjects OBJECT IDENTIFIER + ::= { aristaEntSensorMIB 1 } + +aristaEntSensorMibConformance OBJECT IDENTIFIER + ::= { aristaEntSensorMIB 2 } + +-- entity threshold table -- + +aristaEntSensorThresholdTable OBJECT-TYPE + SYNTAX SEQUENCE OF AristaEntSensorThresholdEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table contains threshold information for the + various sensors in the system." + ::= { aristaEntSensorMibObjects 1 } + +aristaEntSensorThresholdEntry OBJECT-TYPE + SYNTAX AristaEntSensorThresholdEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A single row containing threshold information for a + sensor. Threshold values are reported using the unit + of EntitySensorValue. If a sensor does not support threshold + data, then an underflow/overflow value is returned. + All the other relevant information for the given sensor can be + obtained from the entPhySensorTable itself." + INDEX { entPhysicalIndex } + ::= { aristaEntSensorThresholdTable 1 } + +AristaEntSensorThresholdEntry ::= SEQUENCE { + aristaEntSensorThresholdLowWarning EntitySensorValue, + aristaEntSensorThresholdLowCritical EntitySensorValue, + aristaEntSensorThresholdHighWarning EntitySensorValue, + aristaEntSensorThresholdHighCritical EntitySensorValue, + aristaEntSensorStatusDescr SnmpAdminString +} + +aristaEntSensorThresholdLowWarning OBJECT-TYPE + SYNTAX EntitySensorValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The low thresold value for the given sensor at which point + the entity's alarm status is set to warning." + ::= { aristaEntSensorThresholdEntry 1 } + +aristaEntSensorThresholdLowCritical OBJECT-TYPE + SYNTAX EntitySensorValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The low critical value for the given sensor at which point + the entity's alarm status is set to critical." + ::= { aristaEntSensorThresholdEntry 2 } + +aristaEntSensorThresholdHighWarning OBJECT-TYPE + SYNTAX EntitySensorValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The high thresold value for the given sensor at which point + the entity's alarm status is set to warning." + ::= { aristaEntSensorThresholdEntry 3 } + +aristaEntSensorThresholdHighCritical OBJECT-TYPE + SYNTAX EntitySensorValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The high critical value for the given sensor at which point + the entity's alarm status is set to critical." + ::= { aristaEntSensorThresholdEntry 4 } + +aristaEntSensorStatusDescr OBJECT-TYPE + SYNTAX SnmpAdminString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A textual description of the current status of the sensor. + It serves as a human-readable representation of the operating + status including any threshold alerts." + ::= { aristaEntSensorThresholdEntry 5 } + + +-- Notifications -- + +aristaEntSensorAlarm NOTIFICATION-TYPE + OBJECTS { + entPhysicalDescr, entPhySensorValue, entStateAlarm + } + STATUS current + DESCRIPTION + "This notification is generated under 2 conditions: + a) When the value of the sensor value crosses a supported + low or high threshold into warning or critical status. + b) If previously the sensor value was in a warning or + critical status but returns back to a normal status." + ::= { aristaEntSensorMibNotifications 1 } + + +-- Conformance and Compliance + +aristaEntSensorMibCompliances OBJECT IDENTIFIER + ::= { aristaEntSensorMibConformance 1 } + +aristaEntSensorMibGroups OBJECT IDENTIFIER + ::= { aristaEntSensorMibConformance 2 } + +aristaEntSensorMibCompliance MODULE-COMPLIANCE + STATUS current + DESCRIPTION + "The compliance statement for Arista switches that implement + the ARISTA-ENTITY-SENSOR-MIB." + MODULE -- this module + MANDATORY-GROUPS { + aristaEntSensorThresholdGroup, + aristaEntSensorNotificationsGroup + } + ::= { aristaEntSensorMibCompliances 1 } + +aristaEntSensorThresholdGroup OBJECT-GROUP + OBJECTS { + aristaEntSensorThresholdLowWarning, + aristaEntSensorThresholdLowCritical, + aristaEntSensorThresholdHighWarning, + aristaEntSensorThresholdHighCritical, + aristaEntSensorStatusDescr + } + STATUS current + DESCRIPTION + "The collection of objects that provide threshold + information for the sensors in the system." + ::= { aristaEntSensorMibGroups 1 } + +aristaEntSensorNotificationsGroup NOTIFICATION-GROUP + NOTIFICATIONS { + aristaEntSensorAlarm + } + STATUS current + DESCRIPTION + "The collection of notifications generated by the system if + sensor(s) change value are not within the acceptable operating + range." + ::= { aristaEntSensorMibGroups 2 } + +END + + |