summaryrefslogtreecommitdiff
path: root/MIBS/arris/d5/SIM-MIB
diff options
context:
space:
mode:
Diffstat (limited to 'MIBS/arris/d5/SIM-MIB')
-rw-r--r--MIBS/arris/d5/SIM-MIB2823
1 files changed, 2823 insertions, 0 deletions
diff --git a/MIBS/arris/d5/SIM-MIB b/MIBS/arris/d5/SIM-MIB
new file mode 100644
index 0000000..043e428
--- /dev/null
+++ b/MIBS/arris/d5/SIM-MIB
@@ -0,0 +1,2823 @@
+SIM-MIB DEFINITIONS ::= BEGIN
+
+IMPORTS
+ MODULE-IDENTITY, OBJECT-TYPE, Unsigned32, Counter32, IpAddress, BITS, enterprises
+ FROM SNMPv2-SMI
+ TEXTUAL-CONVENTION, RowStatus, DisplayString
+ FROM SNMPv2-TC
+ MODULE-COMPLIANCE, OBJECT-GROUP
+ FROM SNMPv2-CONF;
+
+simMIB MODULE-IDENTITY
+ LAST-UPDATED "9707021700Z"
+ORGANIZATION "DVB Simulcrypt Technical Group" CONTACT-INFO " --- "
+ DESCRIPTION
+"The MIB module for defining DVB Simulcrypt Conditional
+ Access System configuration information."
+ ::= { enterprises 2696 1 1 }
+
+ECMGCSuCasId ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "Adding this to fix compile issue"
+ SYNTAX Unsigned32
+
+Signed16 ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "Adding this to fix compile issue"
+ SYNTAX INTEGER (0..65535)
+
+AdministrativeState ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+"Administrative state as defined by ITU-T Recommendation X.734"
+ SYNTAX BITS
+ {
+ locked(0),
+ unlocked(1),
+ shuttingDown(2)
+ }
+
+CaDescInsMode ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+"Conditional Access Descriptor Insertion Type."
+ SYNTAX BITS
+ {
+ psigInsertion(0),
+ noPsigInsertion(1)
+ }
+
+DelayType ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "Delay type."
+ SYNTAX BITS
+ {
+ immediate(0),
+ synchronized(1)
+ }
+
+DescriptorStatus ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+"The return status of descriptor insertion."
+ SYNTAX BITS
+ {
+ success(0),
+ unknownTrigger(1),
+ unknownLocation(2),
+ unsupportedDelay(3),
+ unknownContext(4),
+ unknownOtherTS(5),
+ unknownNetwork(6),
+ unknownTS(7),
+ unknownES(8),
+ unknownBouquet(9),
+ unknownEvent(10),
+ tableNotSupported(11),
+ tableFull(12),
+ other(13)
+ }
+
+ECMGChannelId ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+"The ECM_channel_ID is represented as a 2 bytes unsigned integer."
+SYNTAX INTEGER (0..65535)
+
+ECMGDelayValue ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+"The value od xxx_Delay_Start / _Stop in ECMG protocol."
+ SYNTAX Signed16
+
+ECMTriggerType ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+"The type of an ECM trigger in a PSI generator."
+ SYNTAX BITS
+ {
+ ecmStreamOpen(0),
+ ecmStreamClose(1),
+ ecmStreamChange(2),
+ accessCriteriaChange(3)
+ }
+
+EMMGChannelId ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+"Indicates the Data Channel Id."
+SYNTAX INTEGER (0..65535)
+
+EMMGCommCapability ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+"Type of communications capability between EMMG/PDG and Multiplexer:
+ TCP or UDP or both."
+ SYNTAX BITS
+ {
+ both(0),
+ tcp(1),
+ udp(2)
+ }
+
+EMMGCommType ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+"Type of communications capability between EMMG/PDG and Multiplexer:
+ TCP or UDP."
+ SYNTAX BITS
+ {
+ tcp(0),
+ udp(1)
+ }
+
+EMMGDataType ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+"Type of data carried in the EMMG/PDG Multiplexer stream."
+ SYNTAX BITS
+ {
+ emm(0),
+ other(1)
+ }
+
+FlowId ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+"The flow identifier is represented as a 2 bytes unsigned integer."
+SYNTAX INTEGER (0..65535)
+
+FlowType ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+"Type of Flow: EMM, ECM, or private data."
+ SYNTAX BITS
+ {
+ ecm(0),
+ emm(1),
+ privatedata(2)
+ }
+
+InsertLocation ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "Descriptor insertion location."
+ SYNTAX BITS
+ {
+ pmtLoop1(0),
+ pmtLoop2(1),
+ cat(2),
+ nitLopp1ActualNet(3),
+ nitLoop2ActualNet(4),
+ nitLopp1OtherNet(5),
+ nitLoop2OtherNet(6),
+ batLoop1(7),
+ batLoop2(8),
+ sdtActualTS(9),
+ sdtOtherTS(10),
+ eitPFActualTS(11),
+ eitPFOtherTS(12),
+ eitScheduleActualTS(13),
+ eitScheduleOtherTS(14)
+ }
+
+ProvTableId ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "Provision table identifier."
+ SYNTAX BITS
+ {
+ pat(0),
+ cat(1),
+ pmt(2),
+ nitActualNet(3),
+ nitOtherNet(4),
+ bat(5),
+ sdtActualTS(6),
+ sdtOtherTS(7),
+ eitPFActualTS(8),
+ eitPFOtherTS(9),
+ eitScheduleActualTS(10),
+ eitScheduleOtherTS(11)
+ }
+
+PsigType ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "Psig type."
+ SYNTAX BITS
+ {
+ sig(0),
+ psig(1),
+ psisig(2)
+ }
+
+SectionTSPktFlag ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+"Format of ECM, EMM, Private data datagrams: section or TS packet."
+ SYNTAX BITS
+ {
+ section(0),
+ tspacket(1)
+ }
+
+StreamId ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+"The Stream_ID is represented as a 2 bytes unsigned integer."
+SYNTAX INTEGER (0..65535)
+
+SuperCasId ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+"SuperCASId / Client_ID: a unsigned 32-bit identifier."
+ SYNTAX Unsigned32
+
+TriggerType ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+"The type of a trigger in a PSI generator."
+ SYNTAX BITS
+ {
+ dvbEvent(0),
+ futureDvbEvent(1),
+ newEcmStream(2),
+ flowPidChange(3),
+ accessCriteriaChange(4),
+ ecmStreamClosure(5),
+ pdStreamCEvent(6)
+ }
+
+
+simMIBObjects OBJECT IDENTIFIER ::= { simMIB 1 }
+simMIBConformance OBJECT IDENTIFIER ::= { simMIB 2 }
+
+simIdent OBJECT IDENTIFIER ::= { simMIBObjects 1 }
+simECMG OBJECT IDENTIFIER ::= { simMIBObjects 2 }
+simEMMG OBJECT IDENTIFIER ::= { simMIBObjects 3 }
+simCPSI OBJECT IDENTIFIER ::= { simMIBObjects 4 }
+simPSI OBJECT IDENTIFIER ::= { simMIBObjects 5 }
+
+
+-- ---------------------------------------------------------------------------------
+-- Ident Group - This group is used for software configuration management
+-- of all Simulcrypt components and includes the following objects:
+--
+
+simSofwareVersion OBJECT-TYPE
+SYNTAX DisplayString (SIZE (80))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"This contains a display string that defines the current version
+ of the software for this unit."
+ ::= { simIdent 1 }
+
+simMIBVersion OBJECT-TYPE
+SYNTAX DisplayString (SIZE (80))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"This contains a display string that defines the current version
+ of the MIB."
+ ::= { simIdent 2}
+
+simMIBPrivateVersion OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (80))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"This contains a display string that defines the current private
+ version of the MIB."
+ ::= { simIdent 3}
+
+simAgentVersion OBJECT-TYPE
+SYNTAX DisplayString (SIZE (80))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"This contains a display string that defines the current version
+ of the agent."
+ ::= { simIdent 4 }
+
+
+-- ---------------------------------------------------------------------------------
+-- ECM Generator Group - This group is used for configuration management and status
+-- monitoring of ECM Generators. It identifies each one of the ECM Generators by the
+-- IP Address and TCP/UDP Port Number. It also associates Super_CAS_IDs, ECM_Channel_IDs,
+-- and ECM_Stream_IDs with ECM Generators. It also associates status information and
+-- statistics with channels and streams. The ECM Generator Group consists of three
+-- conceptual tables. The first table is the interconnection table and is used for
+-- the Headend Network Manager to query the IP addresses and the port number to be used
+-- by an SCS to create a channel. It is indexed by a unique EcmgIndex which is an integer
+-- assigned by the ECMG agent.
+--
+
+simEcmgTable OBJECT-TYPE
+SYNTAX SEQUENCE OF SimEcmgEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+"This table specifies the IP addresses and Port numbers of ECM Generators
+ to be used by headend managers to configure SCSs. This table is to be
+ used in ECM Generators and ECM Generator proxies."
+ ::= { simECMG 1 }
+
+simEcmgEntry OBJECT-TYPE
+ SYNTAX SimEcmgEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+"Information about a single table entry. Depending on whether this is
+an ECMG agent or ECMG proxy agent different table entries can
+be omitted."
+INDEX { simEcmgIndex}
+ ::= { simEcmgTable 1 }
+
+SimEcmgEntry ::= SEQUENCE {
+ simEcmgIndex INTEGER ,
+ simEcmgIpAddress IpAddress,
+ simEcmgTcpPort INTEGER,
+ simEcmgSuCasId SuperCasId,
+ simEcmgChannels Counter32,
+ simEcmgCwPrs Counter32,
+ simEcmgErrs Counter32,
+ simEcmgTargetCpsig INTEGER,
+ simEcmgCaMib OBJECT IDENTIFIER
+}
+
+simEcmgIndex OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"The ECM Generator Table unique index."
+ ::= { simEcmgEntry 1 }
+
+simEcmgIpAddress OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"IP address of the host of the ECMG."
+ ::= { simEcmgEntry 2 }
+
+simEcmgTcpPort OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"TCP port of the ECMG."
+ ::= { simEcmgEntry 3 }
+
+simEcmgSuCasId OBJECT-TYPE
+ SYNTAX SuperCasId
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"The Super_VAS_ID is formed by concatenation of the CA_system_id
+ (16 bit) and the CA_subsystem_ID (16 bit). It defines uniquely a
+ set of ECMGs for a given SCS."
+ ::= { simEcmgEntry 4 }
+
+simEcmgChannels OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"The total number of channels this ECMG is currently maintaining."
+ ::= { simEcmgEntry 5 }
+
+simEcmgCwPrs OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"The total number of CW provisioning requests received by this ECMG."
+ ::= { simEcmgEntry 6 }
+
+simEcmgErrs OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"The total number of communications errors for this ECMG."
+ ::= { simEcmgEntry 7 }
+
+simEcmgTargetCpsig OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"The index into the C(P)SIG table identifying the C(P)SIG associated
+ with this ECMG."
+ ::= { simEcmgEntry 8 }
+
+simEcmgCaMib OBJECT-TYPE
+ SYNTAX OBJECT IDENTIFIER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"The pointer to a provider proprietary MIB (like ifSpecific
+in the interfaces group of MIB II."
+ ::= { simEcmgEntry 9 }
+
+-- ---------------------------------------------------------------------------------
+-- ECMG Channel Table - Used for monitoring channel information. It is indexed
+-- by the ECMG Index from the ECMG table and the ChannelId.
+--
+
+simEcmgCTable OBJECT-TYPE
+SYNTAX SEQUENCE OF SimEcmgCEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+"This table specifies information relating to ECMG/SCS channels including
+ the IP addresses and Port numbers of SCSs communicating
+ with the ECMG Generators. "
+ ::= { simECMG 2 }
+
+simEcmgCEntry OBJECT-TYPE
+ SYNTAX SimEcmgCEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+"Information about a single table entry. Depending on whether this is
+ an ECMG agent or ECMG proxy agent different table entries can be
+ omitted."
+INDEX { simEcmgIndex, simEcmgChannelId}
+ ::= { simEcmgCTable 1 }
+
+SimEcmgCEntry ::= SEQUENCE {
+ simEcmgChannelId ECMGChannelId,
+ simEcmgCScsIpAddress IpAddress,
+ simEcmgCScsTcpPort INTEGER,
+ simEcmgCStreams Counter32,
+ simEcmgCCwPrs Counter32,
+ simEcmgCErrs Counter32,
+ simEcmgCSuCasId ECMGCSuCasId,
+ simEcmgFormat SectionTSPktFlag,
+ simACDelayStart ECMGDelayValue,
+ simACDelayStop ECMGDelayValue,
+ simDelayStart ECMGDelayValue,
+ simDelayStop ECMGDelayValue,
+ simTransitionDelayStart ECMGDelayValue,
+ simTransitionDelayStop ECMGDelayValue,
+ simECMRepPeriod INTEGER,
+ simMaxStreams Counter32,
+ simMinCPDuration INTEGER,
+ simLeadCW Counter32,
+ simCWPerMsg Counter32,
+ simMaxCompTime INTEGER
+ }
+
+simEcmgChannelId OBJECT-TYPE
+ SYNTAX ECMGChannelId
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"The ECMG/SCS Channel identifier."
+ ::= { simEcmgCEntry 1 }
+
+simEcmgCScsIpAddress OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"IP address of the SCS."
+ ::= { simEcmgCEntry 2 }
+
+simEcmgCScsTcpPort OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"TCP port of the SCS."
+ ::= { simEcmgCEntry 3 }
+
+simEcmgCStreams OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"The total number of streams this ECMG is currently maintaining on this channel."
+ ::= { simEcmgCEntry 4 }
+
+simEcmgCCwPrs OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of CW provisioning requests received by this ECMG on this channel."
+ ::= { simEcmgCEntry 5 }
+
+simEcmgCErrs OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of communications errors for this ECMG on this channel."
+ ::= { simEcmgCEntry 6 }
+
+simEcmgCSuCasId OBJECT-TYPE
+ SYNTAX ECMGCSuCasId
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The SuperCASId of the current Channel."
+ ::= { simEcmgCEntry 7 }
+
+simEcmgFormat OBJECT-TYPE
+ SYNTAX SectionTSPktFlag
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Format of datagrams : section or TS Packet."
+ ::= { simEcmgCEntry 8 }
+
+simACDelayStart OBJECT-TYPE
+ SYNTAX ECMGDelayValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"Value of AC_Delay_Start parameter in ECMG protocol, imposed by CAS."
+ ::= { simEcmgCEntry 9 }
+
+simACDelayStop OBJECT-TYPE
+ SYNTAX ECMGDelayValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"Value of AC_Delay_Stop parameter in ECMG protocol, imposed by CAS."
+ ::= { simEcmgCEntry 10 }
+
+simDelayStart OBJECT-TYPE
+ SYNTAX ECMGDelayValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"Value of Delay_Start parameter in ECMG protocol, imposed by CAS."
+ ::= { simEcmgCEntry 11 }
+
+simDelayStop OBJECT-TYPE
+ SYNTAX ECMGDelayValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"Value of Delay_Stop parameter in ECMG protocol, imposed by CAS."
+ ::= { simEcmgCEntry 12 }
+
+simTransitionDelayStart OBJECT-TYPE
+ SYNTAX ECMGDelayValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"Value of Transition_Delay_Start parameter in ECMG protocol, imposed by CAS."
+ ::= { simEcmgCEntry 13 }
+
+simTransitionDelayStop OBJECT-TYPE
+ SYNTAX ECMGDelayValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"Value of Transition_Delay_Stop parameter in ECMG protocol, imposed by CAS."
+ ::= { simEcmgCEntry 14 }
+
+simECMRepPeriod OBJECT-TYPE
+ SYNTAX INTEGER(0..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"Repeating period of ECM defined by CAS and applied by SCS."
+ ::= { simEcmgCEntry 15 }
+
+simMaxStreams OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"Max number of streams supported by the ECMG."
+ ::= { simEcmgCEntry 16 }
+
+simMinCPDuration OBJECT-TYPE
+ SYNTAX INTEGER(0..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"Min crypto-period length supported by the ECMG."
+ ::= { simEcmgCEntry 17 }
+
+simLeadCW OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"Number of CW the ecmg needs in advance."
+ ::= { simEcmgCEntry 18 }
+
+simCWPerMsg OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"Number of CW the ecmg needs in each ECM request."
+ ::= { simEcmgCEntry 19 }
+
+simMaxCompTime OBJECT-TYPE
+ SYNTAX INTEGER(0..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"Max delay supported by the ECMG for providing an ECM."
+ ::= { simEcmgCEntry 20 }
+
+
+-- ---------------------------------------------------------------------------------
+-- ECMG Stream Table - Used for monitoring stream information. It is indexed
+-- by the ECMG Index from the ECMG table, the ChannelId from the Channel Table
+-- and the StreamId.
+--
+
+simEcmgSTable OBJECT-TYPE
+SYNTAX SEQUENCE OF SimEcmgSEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+"This table specifies information relating to ECMG/SCS streams. "
+ ::= { simECMG 3 }
+
+simEcmgSEntry OBJECT-TYPE
+ SYNTAX SimEcmgSEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+"Information about a single table entry. Depending on whether this is
+an ECMG agent or ECMG proxy agent different table entries can be omitted."
+ INDEX { simEcmgIndex, simEcmgChannelId, simEcmgStreamId}
+ ::= { simEcmgSTable 1 }
+
+SimEcmgSEntry ::= SEQUENCE {
+ simEcmgStreamId StreamId,
+ simEcmgEcmId FlowId,
+ simEcmgSLastCp Unsigned32,
+ simEcmgSCwPrs Counter32,
+ simEcmgSErrs Counter32
+ }
+
+simEcmgStreamId OBJECT-TYPE
+ SYNTAX StreamId
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"The ECMG/SCS Stream identifier."
+ ::= { simEcmgSEntry 1 }
+
+simEcmgEcmId OBJECT-TYPE
+ SYNTAX FlowId
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"The unique ECM flow identifier."
+ ::= { simEcmgSEntry 2 }
+
+simEcmgSLastCp OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"The number of the crypto-period last processed on this stream."
+ ::= { simEcmgSEntry 3 }
+
+simEcmgSCwPrs OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"The total number of CW provisioning requests received by this ECMG on this stream."
+ ::= { simEcmgSEntry 4 }
+
+simEcmgSErrs OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"The total number of communications errors for this ECMG on this stream."
+ ::= { simEcmgSEntry 5 }
+
+-- ---------------------------------------------------------------------------------
+-- EMM/PD Generator Group - This group is used for management of EMM/PD Generators.
+-- It identifies each one of the EMM/PD Generators by the IP Address and TCP/UDP Port
+-- Number.It also associates Client_IDs, Data_stream_IDs, and Data_Channel_IDs with EMM/PD
+-- Generators. It also associates status information and statistics with streams. The
+-- EMMG/PDG Generator Group consists of four conceptual tables. The first table is used
+-- for information relevant to EMMG/PDG and is indexed by a unique EmOrPdIndex which is
+-- assigned by the EMMG/PDG agent.
+--
+
+simEmOrPdTable OBJECT-TYPE
+SYNTAX SEQUENCE OF SimEmOrPdEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+"This table defines the EMMG or PDG interfaces to the MUX and is to be
+ used in EMMGs/PDGs and optionally the multiplexer."
+ ::= { simEMMG 1 }
+
+simEmOrPdEntry OBJECT-TYPE
+ SYNTAX SimEmOrPdEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+"Information about a single table entry. Depending on whether this is an
+ EMMG/PDG or multiplexer agent different table entries can be omitted."
+ INDEX { simEmOrPdIndex }
+ ::= { simEmOrPdTable 1 }
+
+SimEmOrPdEntry ::= SEQUENCE {
+ simEmOrPdIndex INTEGER,
+ simEmOrPdDataType EMMGDataType,
+ simEmOrPdClientId SuperCasId,
+ simEmOrPdCommCapability EMMGCommCapability,
+ simEmOrPdErrs Counter32,
+ simEmOrPdTargetCpsig INTEGER,
+ simEmOrPdCaMib OBJECT IDENTIFIER
+ }
+
+simEmOrPdIndex OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"Unique index into the EMMG or PDG table. "
+ ::= { simEmOrPdEntry 1 }
+
+simEmOrPdDataType OBJECT-TYPE
+ SYNTAX EMMGDataType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"Data_type: Type of data handled by this EMMG/PDG. "
+ ::= { simEmOrPdEntry 2 }
+
+simEmOrPdClientId OBJECT-TYPE
+ SYNTAX SuperCasId
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"Client_ID: The Client_ID is a 32-bit identifier. It shall identify uniquely
+ an EMMG/PDG across all the EMMGs/PDGs connected to a given MUX. To facilitate
+ uniqueness of this value, the following rules apply:
+* In the case of EMMs or other CA related data, the two first bytes of the
+ client_id should be equal to the two bytes of the corresponding CA_system_ID.
+* In other cases a value allocated by DVB for this purpose should be used."
+ ::= { simEmOrPdEntry 3 }
+
+simEmOrPdCommCapability OBJECT-TYPE
+ SYNTAX EMMGCommCapability
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"Communication capability between EMMG/PDG and the multiplexer. Currently
+ TCP or UDP or both."
+ ::= { simEmOrPdEntry 4 }
+
+simEmOrPdErrs OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"The total number of communications errors for this EMMG/PDG."
+ ::= { simEmOrPdEntry 5 }
+
+simEmOrPdTargetCpsig OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+"The index into the C(P)SIG table identifying the C(P)SIG associated
+ with this EMMG/PDG."
+ ::= { simEmOrPdEntry 6 }
+
+simEmOrPdCaMib OBJECT-TYPE
+ SYNTAX OBJECT IDENTIFIER
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+"Pointer to a vendor proprietary extension to the EMMG/PDG MIB group."
+ ::= { simEmOrPdEntry 7 }
+
+
+-- ---------------------------------------------------------------------------------
+-- EMMG/PDG Logical Access Point Table - The second EMM Generator/ PD Generator table
+-- is used for configuration of the EMMGs/PDGs. It is uniquely indexed by the
+-- EmOrPdLapIndex which is a globally assigned quantity (with respect to the headend)
+-- and associates globally assigned Logical Access Points (LAPs) with mux ports.
+--
+
+simEmOrPdLapTable OBJECT-TYPE
+SYNTAX SEQUENCE OF SimEmOrPdLapEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+"This table is used for configuration of EMM/PD Generators."
+ ::= { simEMMG 2 }
+
+simEmOrPdLapEntry OBJECT-TYPE
+ SYNTAX SimEmOrPdLapEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+"Information about a single table entry."
+ INDEX { simEmOrPdLapIndex }
+ ::= { simEmOrPdLapTable 1 }
+
+SimEmOrPdLapEntry ::= SEQUENCE {
+ simEmOrPdLapIndex INTEGER,
+ simEmOrPdLapAdminState AdministrativeState,
+ simEmOrPdLapCommType EMMGCommType,
+ simEmOrPdLapMuxIpAddress IpAddress,
+ simEmOrPdLapMuxPort INTEGER,
+ simEmOrPdLapStatus RowStatus,
+ simEmOrPdLapMuxUIpAddress IpAddress,
+ simEmOrPdLapMuxUPort INTEGER
+ }
+
+simEmOrPdLapIndex OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"Unique Logical Access Point (LAP) identifier. "
+ ::= { simEmOrPdLapEntry 1 }
+
+simEmOrPdLapAdminState OBJECT-TYPE
+ SYNTAX AdministrativeState
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+" Used by an authorized manager to lock a conceptual row for exclusive
+ write and create access."
+ ::= { simEmOrPdLapEntry 2 }
+
+simEmOrPdLapCommType OBJECT-TYPE
+ SYNTAX EMMGCommType
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+"Type of communication between EMMG/PDG and the multiplexer. Currently TCP or UDP."
+ ::= { simEmOrPdLapEntry 3}
+
+simEmOrPdLapMuxIpAddress OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+"IP address of the multiplexer for EMMG/PDG TCP communication."
+ ::= { simEmOrPdLapEntry 4 }
+
+simEmOrPdLapMuxPort OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+"Port number (TCP) of the multiplexer for EMMG/PDG TCP communication."
+ ::= { simEmOrPdLapEntry 5 }
+
+simEmOrPdLapStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+"Used for table row creation management."
+ ::= { simEmOrPdLapEntry 6 }
+
+simEmOrPdLapMuxUIpAddress OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+"IP address of the multiplexer for EMMG/PDG UDP communication."
+ ::= { simEmOrPdLapEntry 7 }
+
+simEmOrPdLapMuxUPort OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+"Port number (UDP) of the multiplexer for EMMG/PDG UDP communication."
+ ::= { simEmOrPdLapEntry 8 }
+
+-- ---------------------------------------------------------------------------------
+-- EMMG/PDG Logical Access Point Group Table - The third EMM Generator/ PD Generator table
+-- is used for configuration of the EMMGs/PDG. It associates LAP Groups and LAPs and is
+-- uniquely indexed by the EmOrPdLapGroup, and EmOrPdLapIndex.
+--
+
+simEmOrPdLapGTable OBJECT-TYPE
+SYNTAX SEQUENCE OF SimEmOrPdLapGEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+"This table is used for configuration of EMM/PD Generators."
+ ::= { simEMMG 3 }
+
+simEmOrPdLapGEntry OBJECT-TYPE
+ SYNTAX SimEmOrPdLapGEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+"Information about a single table entry."
+INDEX { simEmOrPdLapGroup, simEmOrPdLapIndex }
+ ::= { simEmOrPdLapGTable 1 }
+
+SimEmOrPdLapGEntry ::= SEQUENCE {
+ simEmOrPdLapGroup INTEGER,
+ simEmOrPdLapGAdminState AdministrativeState,
+ simEmOrPdLapGStatus RowStatus
+ }
+
+simEmOrPdLapGroup OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"Logical Access Point (LAP) group. "
+ ::= { simEmOrPdLapGEntry 1 }
+
+simEmOrPdLapGAdminState OBJECT-TYPE
+ SYNTAX AdministrativeState
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+" Used by an authorized manager to lock a conceptual row for exclusive
+ write and create access."
+ ::= { simEmOrPdLapGEntry 2 }
+
+simEmOrPdLapGStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+"Used for table row creation management."
+ ::= { simEmOrPdLapGEntry 3 }
+
+-- ---------------------------------------------------------------------------------
+-- EMMG/PDG Channel Table - Used for monitoring of EMM / PD Generator channels.
+--
+
+simEmOrPdCTable OBJECT-TYPE
+SYNTAX SEQUENCE OF SimEmOrPdCEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+"This table is used for monitoring of channels between Muxes and EMMGs/PDGs."
+ ::= { simEMMG 4 }
+
+simEmOrPdCEntry OBJECT-TYPE
+ SYNTAX SimEmOrPdCEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+"Information about a single table entry."
+INDEX { simEmOrPdIndex, simEmOrPdLapIndex, simEmOrPdChannelId }
+ ::= { simEmOrPdCTable 1 }
+
+SimEmOrPdCEntry ::= SEQUENCE {
+ simEmOrPdChannelId EMMGChannelId,
+ simEmOrPdCommType EMMGCommType,
+ simEmOrPdCIpAddress IpAddress,
+ simEmOrPdCPort INTEGER,
+ simEmOrPdCErrs Counter32,
+ simEmOrPdCFormat SectionTSPktFlag,
+ simEmOrPdCUIpAddress IpAddress,
+ simEmOrPdCUPort INTEGER
+ }
+
+simEmOrPdChannelId OBJECT-TYPE
+ SYNTAX EMMGChannelId
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"Data_channel_ID: This identifier uniquely identifies a
+ EMM/Private Data channel within a client_ID."
+ ::= { simEmOrPdCEntry 1 }
+
+simEmOrPdCommType OBJECT-TYPE
+ SYNTAX EMMGCommType
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+"Communications type: TCP or UDP."
+ ::= { simEmOrPdCEntry 2 }
+
+simEmOrPdCIpAddress OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"IP address of the host of the EMMG or PDG."
+ ::= { simEmOrPdCEntry 3 }
+
+simEmOrPdCPort OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"Port number *TCP or UDP of the EMMG or PDG."
+ ::= { simEmOrPdCEntry 4 }
+
+simEmOrPdCErrs OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"The total number of communications errors on this channel."
+ ::= { simEmOrPdCEntry 5 }
+
+simEmOrPdCFormat OBJECT-TYPE
+ SYNTAX SectionTSPktFlag
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"Format of datagrams : section or TS Packet."
+ ::= { simEmOrPdCEntry 6 }
+
+simEmOrPdCUIpAddress OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"IP address of the host of the EMMG or PDG for UDP."
+ ::= { simEmOrPdCEntry 7 }
+
+simEmOrPdCUPort OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"Port number (UDP) of the EMMG or PDG."
+ ::= { simEmOrPdCEntry 8 }
+
+-- ---------------------------------------------------------------------------------
+-- EMMG/PDG Stream Table - Used for monitoring of EMM / PD Generator streams.
+--
+
+simEmOrPdSTable OBJECT-TYPE
+SYNTAX SEQUENCE OF SimEmOrPdSEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+"This table is used for monitoring of streams between Muxes and EMMGs/PDGs."
+ ::= { simEMMG 5 }
+
+simEmOrPdSEntry OBJECT-TYPE
+ SYNTAX SimEmOrPdSEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+"Information about a single table entry."
+ INDEX { simEmOrPdIndex, simEmOrPdLapIndex, simEmOrPdDataId }
+ ::= { simEmOrPdSTable 1 }
+
+SimEmOrPdSEntry ::= SEQUENCE {
+ simEmOrPdDataId FlowId,
+ simEmOrPdSChannelId EMMGChannelId,
+ simEmOrPdBwidth Unsigned32,
+ simEmOrPdStreamId StreamId,
+ simEmOrPdSErrs Counter32,
+ simEmOrPdSBytes Counter32,
+ simEmOrPdSReqBwidth Unsigned32
+ }
+
+simEmOrPdDataId OBJECT-TYPE
+ SYNTAX FlowId
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+"DataID: This identifier uniquely identifies a EMM/Private Data stream."
+ ::= { simEmOrPdSEntry 1 }
+
+simEmOrPdSChannelId OBJECT-TYPE
+ SYNTAX EMMGChannelId
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Channel identifier."
+ ::= { simEmOrPdSEntry 2 }
+
+simEmOrPdBwidth OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Negotiated Bandwidth."
+ ::= { simEmOrPdSEntry 3 }
+
+simEmOrPdStreamId OBJECT-TYPE
+ SYNTAX StreamId
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"Data_stream_ID: This identifier uniquely identifies a EMM/Private
+ Data stream within a channel."
+ ::= { simEmOrPdSEntry 4 }
+
+simEmOrPdSErrs OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"The total number of communications errors on this stream."
+ ::= { simEmOrPdSEntry 5 }
+
+simEmOrPdSBytes OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"The total number of bytes sent by this EMMG/PDG on this stream."
+ ::= { simEmOrPdSEntry 6 }
+
+simEmOrPdSReqBwidth OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+" Bandwidth as requested by CAS."
+ ::= { simEmOrPdSEntry 7 }
+
+-- ---------------------------------------------------------------------------------
+-- C(P)SIG) Group - This Group is used for management of some aspects of interaction
+-- between the custom PSI Generators (C(P)SIG)) and the PSI Generator. It consists of
+-- three tables. The first table is used for advertising C(P)SIG) information by the
+-- C(P)SIG) host. The second table is used for the manager to configure the C(P)SIG).
+-- The third and fourth tables are used for C(P)SIG) channel and stream monitoring.
+--
+
+
+simCpsigTable OBJECT-TYPE
+SYNTAX SEQUENCE OF SimCpsigEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+"This table defines the C(P)SIG) interfaces to the Mux and is to be
+ used in the C(P)SIG and optionally the multiplexer."
+ ::= { simCPSI 1 }
+
+simCpsigEntry OBJECT-TYPE
+ SYNTAX SimCpsigEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+"Information about a single table entry. Depending on whether this is an
+ EMMG/PDG or multiplexer agent different table entries can be omitted."
+ INDEX { simCpsigIndex }
+ ::= { simCpsigTable 1 }
+
+SimCpsigEntry ::= SEQUENCE {
+ simCpsigIndex INTEGER,
+ simCpsigSuperCasId SuperCasId,
+ simCpsigErrs Counter32,
+ simCpsigChannels Counter32,
+ simCpsigCpsigIpAddress IpAddress,
+ simCpsigCpsigPort INTEGER,
+ simCpsigCaMib OBJECT IDENTIFIER
+ }
+
+simCpsigIndex OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"Unique index into the Cpsig table. "
+ ::= { simCpsigEntry 1 }
+
+simCpsigSuperCasId OBJECT-TYPE
+ SYNTAX SuperCasId
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "super_CAS_id "
+ ::= { simCpsigEntry 2 }
+
+simCpsigErrs OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"The total number of communication errors for this C(P)SIG)."
+ ::= { simCpsigEntry 3 }
+
+simCpsigChannels OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"The total number of channels for this C(P)SIG)."
+ ::= { simCpsigEntry 4 }
+
+simCpsigCpsigIpAddress OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"The IP Address of the C(P)SIG)."
+ ::= { simCpsigEntry 5 }
+
+simCpsigCpsigPort OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"The TCP port number of the C(P)SIG)."
+ ::= { simCpsigEntry 6 }
+
+simCpsigCaMib OBJECT-TYPE
+ SYNTAX OBJECT IDENTIFIER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+" Pointer to a vendor proprietary extension to the C(P)SIG) MIB group."
+ ::= { simCpsigEntry 7 }
+
+
+-- ---------------------------------------------------------------------------------
+-- C(P)SIG) Channel Table - Used for monitoring of C(P)SIG channels.
+--
+
+simCpsigCTable OBJECT-TYPE
+SYNTAX SEQUENCE OF SimCpsigCEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+"This table is used for monitoring of channels between (P)SIGs and C(P)SIGs."
+ ::= { simCPSI 2 }
+
+simCpsigCEntry OBJECT-TYPE
+ SYNTAX SimCpsigCEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+" Information about a single table entry."
+ INDEX { simCpsigIndex, simCpsigChannelId }
+ ::= { simCpsigCTable 1 }
+
+SimCpsigCEntry ::= SEQUENCE {
+ simCpsigChannelId INTEGER,
+ simCpsigPsigIpAddress IpAddress,
+ simCpsigPsigPort INTEGER,
+ simCpsigCErrs Counter32,
+ simCpsigCTstrms Counter32,
+ simCpsigCSstrms Counter32
+ }
+
+simCpsigChannelId OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"ChannelId identifies the C(P)SIG channel."
+ ::= { simCpsigCEntry 1 }
+
+simCpsigPsigIpAddress OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"IP address of the host of the (P)SIG."
+ ::= { simCpsigCEntry 2 }
+
+simCpsigPsigPort OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"TCP Port number of the (P)SIG."
+ ::= { simCpsigCEntry 3 }
+
+simCpsigCErrs OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"The total number of communication errors on this channel."
+ ::= { simCpsigCEntry 4 }
+
+simCpsigCTstrms OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"The total number of transport streams on this channel."
+ ::= { simCpsigCEntry 5 }
+
+simCpsigCSstrms OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"The total number of service streams on this channel."
+ ::= { simCpsigCEntry 6 }
+
+-- ---------------------------------------------------------------------------------
+-- C(P)SIG Stream Table - Used for monitoring of C(P)SIG) streams.
+--
+
+simCpsigStreamTable OBJECT-TYPE
+SYNTAX SEQUENCE OF SimCpsigStreamEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+"This table is used for monitoring of streams between Muxes and C(P)SIG)s."
+ ::= { simCPSI 3 }
+
+simCpsigStreamEntry OBJECT-TYPE
+ SYNTAX SimCpsigStreamEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+"Information about a single table entry."
+ INDEX { simCpsigIndex, simCpsigChannelId, simCpsigStreamId }
+ ::= { simCpsigStreamTable 1 }
+
+SimCpsigStreamEntry ::= SEQUENCE {
+ simCpsigStreamId INTEGER,
+ simCpsigStreamTStreamId INTEGER,
+ simCpsigStreamNid INTEGER,
+ simCpsigStreamOnid INTEGER,
+ simCpsigStreamMaxCompTime INTEGER,
+ simCpsigStreamTriggerEnable TriggerType,
+ simCpsigStreamLastTrigger TriggerType,
+ simCpsigStreamLastEventId INTEGER,
+ simCpsigStreamLastServiceId INTEGER,
+ simCpsigStreamLastEsId INTEGER,
+ simCpsigStreamLastEcmPid INTEGER,
+ simCpsigStreamErrs Counter32,
+ simCpsigStreamBytes Counter32
+ }
+
+simCpsigStreamId OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+"This identifier uniquely identifies a C(P)SIG) stream"
+ ::= { simCpsigStreamEntry 1 }
+
+simCpsigStreamTStreamId OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"This identifier uniquely identifies a C(P)SIG transport stream"
+ ::= { simCpsigStreamEntry 2 }
+
+simCpsigStreamNid OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"This identifier uniquely identifies the network id associated with the stream"
+ ::= { simCpsigStreamEntry 3 }
+
+simCpsigStreamOnid OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"This identifier uniquely identifies the original network
+ id associated with the stream"
+ ::= { simCpsigStreamEntry 4 }
+
+simCpsigStreamMaxCompTime OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"Max Computation time by the C(P)SIG."
+ ::= { simCpsigStreamEntry 5 }
+
+simCpsigStreamTriggerEnable OBJECT-TYPE
+ SYNTAX TriggerType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"Triggers enabled by the C(P)SIG."
+ ::= { simCpsigStreamEntry 6 }
+
+simCpsigStreamLastTrigger OBJECT-TYPE
+ SYNTAX TriggerType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"Last trigger processed by the C(P)SIG."
+ ::= { simCpsigStreamEntry 7 }
+
+simCpsigStreamLastEventId OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"Last event id processed by the C(P)SIG."
+ ::= { simCpsigStreamEntry 8 }
+
+simCpsigStreamLastServiceId OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"Last service id processed by the C(P)SIG."
+ ::= { simCpsigStreamEntry 9 }
+
+simCpsigStreamLastEsId OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"Last elementary stream id processed by the C(P)SIG."
+ ::= { simCpsigStreamEntry 10 }
+
+simCpsigStreamLastEcmPid OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"Last ECM pid processed by the C(P)SIG."
+ ::= { simCpsigStreamEntry 11 }
+
+simCpsigStreamErrs OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"The total number of communication errors on this stream."
+ ::= { simCpsigStreamEntry 12 }
+
+simCpsigStreamBytes OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"The total number of bytes sent by this EMMG/PDG on this stream."
+ ::= { simCpsigStreamEntry 13 }
+
+-- ---------------------------------------------------------------------------------
+-- (P)SIG Group - This Group is used for the synchronization and information
+-- exchange between the PSI Generator and Custom PSI Generators and
+-- between the SI Generator and Custom SI Generators.
+--
+
+simPsigTable OBJECT-TYPE
+SYNTAX SEQUENCE OF SimPsigEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+"This table advertises the (P)SIG configuration information. "
+ ::= { simPSI 1 }
+
+simPsigEntry OBJECT-TYPE
+ SYNTAX SimPsigEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+"Information about a single table entry. "
+INDEX { simPsigIndex }
+ ::= { simPsigTable 1 }
+
+SimPsigEntry ::= SEQUENCE {
+ simPsigIndex INTEGER,
+ simPsigType PsigType,
+ simPsigTriggerSupport TriggerType,
+ simPsigNetworkId INTEGER,
+ simPsigONetworkId INTEGER,
+ simPsigTransStreamId INTEGER,
+ simPsigTSServices OCTET STRING
+ }
+
+simPsigIndex OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"The unique index into the table."
+ ::= { simPsigEntry 1 }
+
+simPsigType OBJECT-TYPE
+ SYNTAX PsigType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Psig type"
+ ::= { simPsigEntry 2 }
+
+simPsigTriggerSupport OBJECT-TYPE
+ SYNTAX TriggerType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"Identifies which trigger types the PSIG supports."
+ ::= { simPsigEntry 3 }
+
+simPsigNetworkId OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Network identifier. "
+ ::= { simPsigEntry 4 }
+
+simPsigONetworkId OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"Original Network identifier. "
+ ::= { simPsigEntry 5 }
+
+simPsigTransStreamId OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"Transport Stream identifier. "
+ ::= { simPsigEntry 6 }
+
+simPsigTSServices OBJECT-TYPE
+SYNTAX OCTET STRING (SIZE(0..511))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"List of service identifies on the transport stream. "
+ ::= { simPsigEntry 7 }
+
+--
+--
+
+simPsigConfigTable OBJECT-TYPE
+SYNTAX SEQUENCE OF SimPsigConfigEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+"This table configures the (P)SIG/(C)PSIG communication. "
+ ::= { simPSI 2 }
+
+simPsigConfigEntry OBJECT-TYPE
+ SYNTAX SimPsigConfigEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+"Information about a single table entry. "
+ INDEX { simPsigConfigCustCasId, simPsigConfigIndex , simPsigIndex}
+ ::= { simPsigConfigTable 1 }
+
+SimPsigConfigEntry ::= SEQUENCE {
+ simPsigConfigIndex INTEGER,
+ simPsigConfigAdminState AdministrativeState,
+ simPsigConfigCpsigType PsigType,
+ simPsigConfigCustCasId SuperCasId,
+ simPsigConfigMaxCompTime INTEGER,
+ simPsigConfigServiceId INTEGER,
+ simPsigConfigTriggerEnable TriggerType,
+ simPsigConfigCADInsMode CaDescInsMode,
+ simPsigConfigEntryStatus RowStatus
+ }
+
+simPsigConfigIndex OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+"The unique index into the table."
+ ::= { simPsigConfigEntry 1 }
+
+simPsigConfigAdminState OBJECT-TYPE
+ SYNTAX AdministrativeState
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+"Used by an authorized manager to lock a conceptual row for exclusive
+ write and create access."
+ ::= { simPsigConfigEntry 2 }
+
+simPsigConfigCpsigType OBJECT-TYPE
+ SYNTAX PsigType
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "C(P)SIG type."
+ ::= { simPsigConfigEntry 3 }
+
+simPsigConfigCustCasId OBJECT-TYPE
+ SYNTAX SuperCasId
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Custom CAS Identifier."
+ ::= { simPsigConfigEntry 4 }
+
+simPsigConfigMaxCompTime OBJECT-TYPE
+ SYNTAX INTEGER(0..65535)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+"Maximum Computing Time. "
+ ::= { simPsigConfigEntry 5 }
+
+simPsigConfigServiceId OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Service identifier. "
+ ::= { simPsigConfigEntry 6 }
+
+simPsigConfigTriggerEnable OBJECT-TYPE
+ SYNTAX TriggerType
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+"Trigger types enabled. "
+ ::= { simPsigConfigEntry 7 }
+
+simPsigConfigCADInsMode OBJECT-TYPE
+ SYNTAX CaDescInsMode
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+"Conditional Access Descriptor Insert mode. "
+ ::= { simPsigConfigEntry 8 }
+
+simPsigConfigEntryStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+"Used for table row creation management."
+ ::= { simPsigConfigEntry 9 }
+
+--
+--
+
+simPsigEcmTrTable OBJECT-TYPE
+SYNTAX SEQUENCE OF SimPsigEcmTrEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+"This table contains all the active ECM Triggers."
+ ::= { simPSI 3 }
+
+simPsigEcmTrEntry OBJECT-TYPE
+ SYNTAX SimPsigEcmTrEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+"Information about a single table entry. "
+ INDEX { simPsigEcmTrIndex }
+ ::= { simPsigEcmTrTable 1 }
+
+SimPsigEcmTrEntry ::= SEQUENCE {
+ simPsigEcmTrIndex INTEGER,
+ simPsigEcmTrNetworkId INTEGER,
+ simPsigEcmTrONetworkId INTEGER,
+ simPsigEcmTrTransStreamId INTEGER,
+ simPsigEcmTrServiceId INTEGER,
+ simPsigEcmTrEsId INTEGER,
+ simPsigEcmTrType ECMTriggerType,
+ simPsigEcmTrSuCasId SuperCasId,
+ simPsigEcmTrEcmId FlowId,
+ simPsigEcmTrEcmPid INTEGER,
+ simPsigEcmTrAccessCriteria OCTET STRING
+ }
+
+simPsigEcmTrIndex OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The trigger index."
+ ::= { simPsigEcmTrEntry 1 }
+
+simPsigEcmTrNetworkId OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The Network Identifier."
+ ::= { simPsigEcmTrEntry 2 }
+
+simPsigEcmTrONetworkId OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+"The Original Network Identifier."
+ ::= { simPsigEcmTrEntry 3 }
+
+simPsigEcmTrTransStreamId OBJECT-TYPE
+ SYNTAX INTEGER(0..65535)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+"Transport Stream Identifier. "
+ ::= { simPsigEcmTrEntry 4 }
+
+simPsigEcmTrServiceId OBJECT-TYPE
+ SYNTAX INTEGER(0..65535)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Service Identifier. "
+ ::= { simPsigEcmTrEntry 5 }
+
+simPsigEcmTrEsId OBJECT-TYPE
+ SYNTAX INTEGER(0..65535)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+"Elementary Stream Identifier. "
+ ::= { simPsigEcmTrEntry 6 }
+
+simPsigEcmTrType OBJECT-TYPE
+ SYNTAX ECMTriggerType
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+"ECM Trigger Type. "
+ ::= { simPsigEcmTrEntry 7 }
+
+simPsigEcmTrSuCasId OBJECT-TYPE
+ SYNTAX SuperCasId
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+"ECM Client Identifier. "
+ ::= { simPsigEcmTrEntry 8 }
+
+simPsigEcmTrEcmId OBJECT-TYPE
+ SYNTAX FlowId
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+"ECM Stream Identifier. "
+ ::= { simPsigEcmTrEntry 9 }
+
+simPsigEcmTrEcmPid OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "ECM PID "
+ ::= { simPsigEcmTrEntry 10 }
+
+simPsigEcmTrAccessCriteria OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(0..127))
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Access criteria. "
+ ::= { simPsigEcmTrEntry 11 }
+
+--
+--
+
+simPsigFlowTrTable OBJECT-TYPE
+SYNTAX SEQUENCE OF SimPsigFlowTrEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+"This table contains all the active Flow Triggers."
+ ::= { simPSI 4 }
+
+simPsigFlowTrEntry OBJECT-TYPE
+ SYNTAX SimPsigFlowTrEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+"Information about a single table entry. "
+ INDEX { simPsigFlowTrIndex }
+ ::= { simPsigFlowTrTable 1 }
+
+SimPsigFlowTrEntry ::= SEQUENCE {
+ simPsigFlowTrIndex INTEGER,
+ simPsigFlowTrType FlowType,
+ simPsigFlowTrSuCasId SuperCasId,
+ simPsigFlowTrFlowId FlowId,
+ simPsigFlowTrFlowPID INTEGER
+ }
+
+simPsigFlowTrIndex OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The trigger index."
+ ::= { simPsigFlowTrEntry 1 }
+
+simPsigFlowTrType OBJECT-TYPE
+ SYNTAX FlowType
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Flow Type. "
+ ::= { simPsigFlowTrEntry 2 }
+
+simPsigFlowTrSuCasId OBJECT-TYPE
+ SYNTAX SuperCasId
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+"Flow Super CAS identifier. "
+ ::= { simPsigFlowTrEntry 3 }
+
+simPsigFlowTrFlowId OBJECT-TYPE
+ SYNTAX FlowId
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+"Flow Stream Identifier. "
+ ::= { simPsigFlowTrEntry 4 }
+
+simPsigFlowTrFlowPID OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Flow PID "
+ ::= { simPsigFlowTrEntry 5 }
+
+--
+--
+
+simPsigEvntTrTable OBJECT-TYPE
+SYNTAX SEQUENCE OF SimPsigEvntTrEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+"This table contains all the active EVNT Triggers."
+ ::= { simPSI 5 }
+
+simPsigEvntTrEntry OBJECT-TYPE
+ SYNTAX SimPsigEvntTrEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+"Information about a single table entry. "
+ INDEX { simPsigEvntTrIndex}
+ ::= { simPsigEvntTrTable 1 }
+
+SimPsigEvntTrEntry ::= SEQUENCE {
+ simPsigEvntTrIndex INTEGER,
+ simPsigEvntTrNetworkId INTEGER,
+ simPsigEvntTrONetworkId INTEGER,
+ simPsigEvntTrTransStreamId INTEGER,
+ simPsigEvntTrServiceId INTEGER,
+ simPsigEvntTrEventId INTEGER,
+ simPsigEvntTrStartTime OCTET STRING,
+ simPsigEvntTrDuration OCTET STRING,
+ simPsigEvntTrPrivateData OCTET STRING
+ }
+
+simPsigEvntTrIndex OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+"The event trigger index."
+ ::= { simPsigEvntTrEntry 1 }
+
+simPsigEvntTrNetworkId OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The Network Identifier."
+ ::= { simPsigEvntTrEntry 2 }
+
+simPsigEvntTrONetworkId OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+"The Original Network Identifier."
+ ::= { simPsigEvntTrEntry 3 }
+
+simPsigEvntTrTransStreamId OBJECT-TYPE
+ SYNTAX INTEGER(0..65535)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+"Transport Stream Identifier. "
+ ::= { simPsigEvntTrEntry 4 }
+
+simPsigEvntTrServiceId OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+" Event trigger service identifier. "
+ ::= { simPsigEvntTrEntry 5 }
+
+simPsigEvntTrEventId OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Event Identifier. "
+ ::= { simPsigEvntTrEntry 6 }
+
+simPsigEvntTrStartTime OBJECT-TYPE
+ SYNTAX OCTET STRING(SIZE (0..4))
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+"Event start time. "
+ ::= { simPsigEvntTrEntry 7 }
+
+simPsigEvntTrDuration OBJECT-TYPE
+ SYNTAX OCTET STRING(SIZE (0..2))
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Event duration. "
+ ::= { simPsigEvntTrEntry 8 }
+
+simPsigEvntTrPrivateData OBJECT-TYPE
+ SYNTAX OCTET STRING(SIZE (0..256))
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+"EVNT Channel Identifier. "
+ ::= { simPsigEvntTrEntry 9 }
+
+--
+--
+
+simPsigDescInsTable OBJECT-TYPE
+SYNTAX SEQUENCE OF SimPsigDescInsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+"This table contains all the information related to descriptor insertion."
+ ::= { simPSI 6 }
+
+simPsigDescInsEntry OBJECT-TYPE
+ SYNTAX SimPsigDescInsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+"Information about a single table entry. "
+INDEX { simPsigDescInsIndex}
+ ::= { simPsigDescInsTable 1 }
+
+SimPsigDescInsEntry ::= SEQUENCE {
+ simPsigDescInsIndex INTEGER,
+ simPsigDescInsAdminState AdministrativeState,
+ simPsigDescInsTrIndex INTEGER,
+ simPsigDescInsTrType TriggerType,
+ simPsigDescInsLocationId InsertLocation,
+ simPsigDescInsNetworkId INTEGER,
+ simPsigDescInsONetworkId INTEGER,
+ simPsigDescInsTransStreamId INTEGER,
+ simPsigDescInsServiceId INTEGER,
+ simPsigDescInsElmStreamId INTEGER,
+ simPsigDescInsBouquetId INTEGER,
+ simPsigDescInsEventId INTEGER,
+ simPsigDescInsONetworkId2loop INTEGER,
+ simPsigDescInsNetworkIdOther INTEGER,
+ simPsigDescInsTransStreamId2OrO INTEGER,
+ simPsigDescInsDelayType DelayType,
+ simPsigDescInsDelay OCTET STRING,
+ simPsigDescPrivDataSpfier INTEGER,
+ simPsigDescInsEntryStatus RowStatus
+ }
+
+simPsigDescInsIndex OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+"The unique index into the table."
+ ::= { simPsigDescInsEntry 1 }
+
+simPsigDescInsAdminState OBJECT-TYPE
+ SYNTAX AdministrativeState
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+"Used by an authorized manager to lock a conceptual row for exclusive
+ write and create access."
+ ::= { simPsigDescInsEntry 2 }
+
+simPsigDescInsTrIndex OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+"The unique index into the corresponding trigger table."
+ ::= { simPsigDescInsEntry 3 }
+
+simPsigDescInsTrType OBJECT-TYPE
+ SYNTAX TriggerType
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+"The type of the trigger that caused this descriptor insert."
+ ::= { simPsigDescInsEntry 4 }
+
+simPsigDescInsLocationId OBJECT-TYPE
+ SYNTAX InsertLocation
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+"The type of target table for insertion."
+ ::= { simPsigDescInsEntry 5 }
+
+simPsigDescInsNetworkId OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The Network Identifier."
+ ::= { simPsigDescInsEntry 6 }
+
+simPsigDescInsONetworkId OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+"The Original Network Identifier."
+ ::= { simPsigDescInsEntry 7 }
+
+simPsigDescInsTransStreamId OBJECT-TYPE
+ SYNTAX INTEGER(0..65535)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+"Transport Stream Identifier. "
+ ::= { simPsigDescInsEntry 8 }
+
+simPsigDescInsServiceId OBJECT-TYPE
+ SYNTAX INTEGER(0..65535)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Service Identifier. "
+ ::= { simPsigDescInsEntry 9 }
+
+simPsigDescInsElmStreamId OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+"Elementary stream identifier. "
+ ::= { simPsigDescInsEntry 10 }
+
+simPsigDescInsBouquetId OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+"Event trigger bouquet identifier. "
+ ::= { simPsigDescInsEntry 11 }
+
+simPsigDescInsEventId OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "EVNT Identifier. "
+ ::= { simPsigDescInsEntry 12 }
+
+simPsigDescInsONetworkId2loop OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+"The Original Network Identifier second loop."
+ ::= { simPsigDescInsEntry 13 }
+
+simPsigDescInsNetworkIdOther OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+"The Network Identifier other."
+ ::= { simPsigDescInsEntry 14 }
+
+simPsigDescInsTransStreamId2OrO OBJECT-TYPE
+ SYNTAX INTEGER(0..65535)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+"Transport Stream Identifier second loop or other. "
+ ::= { simPsigDescInsEntry 15 }
+
+simPsigDescInsDelayType OBJECT-TYPE
+ SYNTAX DelayType
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+"Delay type, immediate or synchronized. "
+ ::= { simPsigDescInsEntry 16 }
+
+simPsigDescInsDelay OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(0..1))
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Insert delay"
+ ::= { simPsigDescInsEntry 17 }
+
+simPsigDescPrivDataSpfier OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Private data specifier"
+ ::= { simPsigDescInsEntry 18 }
+
+simPsigDescInsEntryStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+"Other transport stream identifiers."
+ ::= { simPsigDescInsEntry 19 }
+
+--
+--
+
+simPsigDescInsDescTable OBJECT-TYPE
+SYNTAX SEQUENCE OF SimPsigDescInsDescEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+"This table contains all the descriptors to be inserted."
+ ::= { simPSI 7 }
+
+simPsigDescInsDescEntry OBJECT-TYPE
+ SYNTAX SimPsigDescInsDescEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+"Information about a single table entry. "
+INDEX { simPsigDescInsIndex, simPsigDescInsDescIndex }
+ ::= { simPsigDescInsDescTable 1 }
+
+SimPsigDescInsDescEntry ::= SEQUENCE {
+ simPsigDescInsDescIndex INTEGER,
+ simPsigDescInsDescAdminState AdministrativeState,
+ simPsigDescInsDescriptor OCTET STRING,
+ simPsigDescInsDescriptorStatus DescriptorStatus,
+ simPsigDescInsDescEntryStatus RowStatus
+ }
+
+simPsigDescInsDescIndex OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+"The unique index into the table."
+ ::= { simPsigDescInsDescEntry 1 }
+
+simPsigDescInsDescAdminState OBJECT-TYPE
+ SYNTAX AdministrativeState
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+"Used by an authorized manager to lock a conceptual row for exclusive
+ write and create access."
+ ::= { simPsigDescInsDescEntry 2 }
+
+simPsigDescInsDescriptor OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(0..8191))
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+"The descriptor to be inserted."
+ ::= { simPsigDescInsDescEntry 3 }
+
+simPsigDescInsDescriptorStatus OBJECT-TYPE
+ SYNTAX DescriptorStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+"The insertion status of the descriptor."
+ ::= { simPsigDescInsDescEntry 4 }
+
+simPsigDescInsDescEntryStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+"Other transport stream identifiers."
+ ::= { simPsigDescInsDescEntry 5 }
+
+--
+--
+
+simPsigTblProvTable OBJECT-TYPE
+SYNTAX SEQUENCE OF SimPsigTblProvEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+"This table is the interface to obtaining all PSI/SI information."
+ ::= { simPSI 8 }
+
+simPsigTblProvEntry OBJECT-TYPE
+ SYNTAX SimPsigTblProvEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+"Information about a single table entry. "
+INDEX { simPsigTblProvIndex }
+ ::= { simPsigTblProvTable 1 }
+
+SimPsigTblProvEntry ::= SEQUENCE {
+ simPsigTblProvIndex INTEGER,
+ simPsigTblProvTableId ProvTableId,
+ simPsigTblNetworkId INTEGER,
+ simPsigTblONetworkId INTEGER,
+ simPsigTblTransStreamId INTEGER,
+ simPsigTblServiceId INTEGER,
+ simPsigTblBouquetId INTEGER,
+ simPsigTblEventId INTEGER,
+ simPsigTblONetworkId2loop INTEGER,
+ simPsigTblNetworkIdOther INTEGER,
+ simPsigTblTransStreamId2OrO INTEGER,
+ simPsigTblSegmentNr INTEGER,
+ simPsigTblProvPart OCTET STRING,
+ simPsigTblProvPartNumber INTEGER
+ }
+
+simPsigTblProvIndex OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"The unique index into the table."
+ ::= { simPsigTblProvEntry 1 }
+
+simPsigTblProvTableId OBJECT-TYPE
+ SYNTAX ProvTableId
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"The table identifier of the table."
+ ::= { simPsigTblProvEntry 2 }
+
+simPsigTblNetworkId OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The Network Identifier."
+ ::= { simPsigTblProvEntry 3 }
+
+simPsigTblONetworkId OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+"The Original Network Identifier."
+ ::= { simPsigTblProvEntry 4 }
+
+simPsigTblTransStreamId OBJECT-TYPE
+ SYNTAX INTEGER(0..65535)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+"Transport Stream Identifier. "
+ ::= { simPsigTblProvEntry 5 }
+
+simPsigTblServiceId OBJECT-TYPE
+ SYNTAX INTEGER(0..65535)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Service Identifier. "
+ ::= { simPsigTblProvEntry 6 }
+
+simPsigTblBouquetId OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+"Event trigger bouquet identifier. "
+ ::= { simPsigTblProvEntry 7 }
+
+simPsigTblEventId OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Event Identifier "
+ ::= { simPsigTblProvEntry 8 }
+
+simPsigTblONetworkId2loop OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+"The Original Network Identifier second loop."
+ ::= { simPsigTblProvEntry 9 }
+
+simPsigTblNetworkIdOther OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+"The Network Identifier other."
+ ::= { simPsigTblProvEntry 10 }
+
+simPsigTblTransStreamId2OrO OBJECT-TYPE
+ SYNTAX INTEGER(0..65535)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+"Transport Stream Identifier second loop or other. "
+ ::= { simPsigTblProvEntry 11 }
+
+simPsigTblSegmentNr OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Segment Number "
+ ::= { simPsigTblProvEntry 12 }
+
+simPsigTblProvPart OBJECT-TYPE
+SYNTAX OCTET STRING (SIZE(0..8191))
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Event Identifier "
+ ::= { simPsigTblProvEntry 13 }
+
+simPsigTblProvPartNumber OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+"Each table is subdivided into parts for SNMP transport if necessary.
+ The part number identifies the table part of this entry. "
+ ::= { simPsigTblProvEntry 14 }
+
+--
+--
+
+simPsigPIDProvTable OBJECT-TYPE
+SYNTAX SEQUENCE OF SimPsigPIDProvEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+"This is the PID provisioning table."
+ ::= { simPSI 9 }
+
+simPsigPIDProvEntry OBJECT-TYPE
+ SYNTAX SimPsigPIDProvEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+"Information about a single table entry. "
+INDEX { simPsigPIDProvSuCasId, simPsigPIDProvFlowId }
+ ::= { simPsigPIDProvTable 1 }
+
+SimPsigPIDProvEntry ::= SEQUENCE {
+ simPsigPIDProvFlowType FlowType,
+ simPsigPIDProvSuCasId SuperCasId,
+ simPsigPIDProvFlowId FlowId,
+ simPsigPIDProvFlowPID INTEGER
+ }
+
+simPsigPIDProvFlowType OBJECT-TYPE
+ SYNTAX FlowType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Flow Type. "
+ ::= { simPsigPIDProvEntry 1 }
+
+simPsigPIDProvSuCasId OBJECT-TYPE
+ SYNTAX SuperCasId
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"Flow Super CAS identifier. "
+ ::= { simPsigPIDProvEntry 2 }
+
+simPsigPIDProvFlowId OBJECT-TYPE
+ SYNTAX FlowId
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+"Flow Stream Identifier. "
+ ::= { simPsigPIDProvEntry 3 }
+
+simPsigPIDProvFlowPID OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Flow PID "
+ ::= { simPsigPIDProvEntry 4 }
+
+--
+--
+
+simPsigPdTrTable OBJECT-TYPE
+SYNTAX SEQUENCE OF SimPsigPdTrEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+"This table contains all the active Private Data Triggers."
+ ::= { simPSI 10 }
+
+simPsigPdTrEntry OBJECT-TYPE
+ SYNTAX SimPsigPdTrEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+"Information about a single table entry. "
+INDEX { simPsigPdTrIndex }
+ ::= { simPsigPdTrTable 1 }
+
+SimPsigPdTrEntry ::= SEQUENCE {
+ simPsigPdTrIndex INTEGER,
+ simPsigPdTrNetworkId INTEGER,
+ simPsigPdTrONetworkId INTEGER,
+ simPsigPdTrTransStreamId INTEGER,
+ simPsigPdTrServiceId INTEGER,
+ simPsigPdTrEsId INTEGER,
+ simPsigPdTrType ECMTriggerType,
+ simPsigPdTrSuCasId SuperCasId,
+ simPsigPdTrPdId FlowId,
+ simPsigPdTrPdPid INTEGER,
+ simPsigPdTrPdStreamType INTEGER,
+ simPsigPdTrPrivateData OCTET STRING
+ }
+
+
+simPsigPdTrIndex OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The trigger index."
+ ::= { simPsigPdTrEntry 1 }
+
+simPsigPdTrNetworkId OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The Network Identifier."
+ ::= { simPsigPdTrEntry 2 }
+
+simPsigPdTrONetworkId OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+"The Original Network Identifier."
+ ::= { simPsigPdTrEntry 3 }
+
+simPsigPdTrTransStreamId OBJECT-TYPE
+ SYNTAX INTEGER(0..65535)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+"Transport Stream Identifier. "
+ ::= { simPsigPdTrEntry 4 }
+
+simPsigPdTrServiceId OBJECT-TYPE
+ SYNTAX INTEGER(0..65535)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Service Identifier. "
+ ::= { simPsigPdTrEntry 5 }
+
+simPsigPdTrEsId OBJECT-TYPE
+ SYNTAX INTEGER(0..65535)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+"Elementary Stream Identifier. "
+ ::= { simPsigPdTrEntry 6 }
+
+simPsigPdTrType OBJECT-TYPE
+ SYNTAX ECMTriggerType
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+"ECM Trigger Type. "
+ ::= { simPsigPdTrEntry 7 }
+
+simPsigPdTrSuCasId OBJECT-TYPE
+ SYNTAX SuperCasId
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+"ECM Client Identifier. "
+ ::= { simPsigPdTrEntry 8 }
+
+simPsigPdTrPdId OBJECT-TYPE
+ SYNTAX FlowId
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+"ECM Stream Identifier. "
+ ::= { simPsigPdTrEntry 9 }
+
+simPsigPdTrPdPid OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "ECM PID "
+ ::= { simPsigPdTrEntry 10 }
+
+simPsigPdTrPdStreamType OBJECT-TYPE
+ SYNTAX INTEGER (0..255)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+"Stream type of Private Data Stream"
+ ::= { simPsigPdTrEntry 11 }
+
+simPsigPdTrPrivateData OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(0..127))
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+"Private Data string. "
+ ::= { simPsigPdTrEntry 12}
+
+-- ---------------------------------------------------------------------------------
+--
+-- Conformance Information
+--
+
+simCompliances OBJECT IDENTIFIER ::= { simMIBConformance 1 }
+simGroups OBJECT IDENTIFIER ::= { simMIBConformance 2 }
+
+simEcmgCompliance MODULE-COMPLIANCE
+ STATUS current
+ DESCRIPTION
+"The compliance statement for SNMP Entities which host or represent ECMGs"
+MODULE -- this module
+MANDATORY-GROUPS { simIdentGroup, simEcmgGroup}
+ ::= { simCompliances 1}
+
+simEmOrPdCompliance MODULE-COMPLIANCE
+ STATUS current
+ DESCRIPTION
+"The compliance statement for SNMP Entities which host or
+ represent EMMGs or PDGs"
+MODULE -- this module
+MANDATORY-GROUPS { simIdentGroup, simEmOrPdGroup}
+ GROUP simEmOrPdLapGGroup
+ DESCRIPTION
+"Allows for grouping of LAPs "
+ ::= { simCompliances 2}
+
+simCpsigCompliance MODULE-COMPLIANCE
+ STATUS current
+ DESCRIPTION
+"The compliance statement for SNMP Entities which host or
+ represent C(P)SIG)s"
+MODULE -- this module
+MANDATORY-GROUPS { simIdentGroup, simCpsigGroup}
+ ::= { simCompliances 3}
+
+simPsigCompliance MODULE-COMPLIANCE
+ STATUS current
+ DESCRIPTION
+"The compliance statement for SNMP Entities which host or
+ represent (P)SIG)s"
+MODULE -- this module
+MANDATORY-GROUPS { simIdentGroup, simPsigGroup}
+ ::= { simCompliances 4}
+
+simIdentGroup OBJECT-GROUP
+ OBJECTS {
+ simSofwareVersion,
+ simMIBVersion,
+ simMIBPrivateVersion,
+ simAgentVersion
+ }
+ STATUS current
+ DESCRIPTION
+"A collection of objects providing software configuration infomation."
+ ::= { simGroups 1 }
+
+simEcmgGroup OBJECT-GROUP
+ OBJECTS {
+ simEcmgIndex,
+ simEcmgIpAddress,
+ simEcmgTcpPort,
+ simEcmgSuCasId,
+ simEcmgChannels,
+ simEcmgCwPrs,
+ simEcmgErrs,
+ simEcmgTargetCpsig,
+ simEcmgCaMib ,
+ simEcmgChannelId,
+ simEcmgCScsIpAddress,
+ simEcmgCScsTcpPort,
+ simEcmgCStreams,
+ simEcmgCCwPrs,
+ simEcmgCErrs,
+ simEcmgStreamId,
+ simEcmgEcmId,
+ simEcmgSLastCp,
+ simEcmgSCwPrs,
+ simEcmgSErrs
+ }
+ STATUS current
+ DESCRIPTION
+" A collection of objects providing ECMG infomation."
+ ::= { simGroups 2 }
+
+simEmOrPdGroup OBJECT-GROUP
+ OBJECTS {
+ simEmOrPdIndex,
+ simEmOrPdDataType,
+ simEmOrPdClientId,
+ simEmOrPdCommCapability,
+ simEmOrPdErrs,
+ simEmOrPdTargetCpsig ,
+ simEmOrPdCaMib,
+ simEmOrPdLapIndex,
+ simEmOrPdLapAdminState,
+ simEmOrPdLapCommType,
+ simEmOrPdLapMuxIpAddress,
+ simEmOrPdLapMuxPort,
+ simEmOrPdLapStatus,
+ simEmOrPdChannelId,
+ simEmOrPdCommType,
+ simEmOrPdCIpAddress,
+ simEmOrPdCPort,
+ simEmOrPdCErrs,
+ simEmOrPdDataId,
+ simEmOrPdSChannelId,
+ simEmOrPdBwidth,
+ simEmOrPdStreamId,
+ simEmOrPdSErrs,
+ simEmOrPdSBytes
+ }
+ STATUS current
+ DESCRIPTION
+" A collection of objects providing EMMG/PDG infomation."
+ ::= { simGroups 3 }
+
+simEmOrPdLapGGroup OBJECT-GROUP
+ OBJECTS {
+ simEmOrPdLapGroup,
+ simEmOrPdLapGAdminState,
+ simEmOrPdLapGStatus
+ }
+ STATUS current
+ DESCRIPTION
+" A collection of objects providing LAPG infomation."
+ ::= { simGroups 4 }
+
+simCpsigGroup OBJECT-GROUP
+ OBJECTS {
+ simCpsigIndex,
+ simCpsigSuperCasId,
+ simCpsigErrs,
+ simCpsigChannels,
+ simCpsigCpsigIpAddress,
+ simCpsigCpsigPort,
+ simCpsigCaMib,
+ simCpsigChannelId,
+ simCpsigPsigIpAddress,
+ simCpsigPsigPort,
+ simCpsigCErrs,
+ simCpsigCTstrms,
+ simCpsigCSstrms,
+ simCpsigStreamTStreamId,
+ simCpsigStreamNid,
+ simCpsigStreamOnid,
+ simCpsigStreamMaxCompTime,
+ simCpsigStreamTriggerEnable,
+ simCpsigStreamLastTrigger,
+ simCpsigStreamLastEventId,
+ simCpsigStreamLastServiceId,
+ simCpsigStreamLastEsId,
+ simCpsigStreamLastEcmPid,
+ simCpsigStreamErrs,
+ simCpsigStreamBytes
+ }
+ STATUS current
+ DESCRIPTION
+"A collection of objects providing C(P)SIG) infomation."
+ ::= { simGroups 5 }
+
+
+simPsigGroup OBJECT-GROUP
+ OBJECTS {
+ simPsigIndex,
+ simPsigType,
+ simPsigTriggerSupport,
+ simPsigNetworkId,
+ simPsigONetworkId,
+ simPsigTransStreamId,
+ simPsigTSServices,
+ simPsigConfigAdminState,
+ simPsigConfigCustCasId,
+ simPsigConfigMaxCompTime,
+ simPsigConfigServiceId,
+ simPsigConfigTriggerEnable,
+ simPsigConfigEntryStatus,
+ simPsigConfigCpsigType,
+ simPsigConfigCADInsMode,
+ simPsigEcmTrNetworkId,
+ simPsigEcmTrONetworkId,
+ simPsigEcmTrTransStreamId,
+ simPsigEcmTrServiceId,
+ simPsigEcmTrEsId,
+ simPsigEcmTrType,
+ simPsigEcmTrSuCasId,
+ simPsigEcmTrEcmId,
+ simPsigEcmTrEcmPid,
+ simPsigEcmTrAccessCriteria,
+ simPsigEvntTrNetworkId,
+ simPsigEvntTrONetworkId,
+ simPsigEvntTrTransStreamId,
+ simPsigEvntTrServiceId,
+ simPsigEvntTrEventId,
+ simPsigEvntTrStartTime,
+ simPsigEvntTrDuration,
+ simPsigEvntTrPrivateData,
+ simPsigFlowTrIndex,
+ simPsigFlowTrType,
+ simPsigFlowTrSuCasId,
+ simPsigFlowTrFlowId,
+ simPsigFlowTrFlowPID,
+ simPsigDescInsIndex,
+ simPsigDescInsAdminState,
+ simPsigDescInsTrIndex,
+ simPsigDescInsTrType,
+ simPsigDescInsLocationId,
+ simPsigDescInsNetworkId,
+ simPsigDescInsONetworkId,
+ simPsigDescInsTransStreamId,
+ simPsigDescInsServiceId,
+ simPsigDescInsElmStreamId,
+ simPsigDescInsBouquetId,
+ simPsigDescInsEventId,
+ simPsigDescInsNetworkIdOther,
+ simPsigDescInsONetworkId2loop,
+ simPsigDescInsTransStreamId2OrO,
+ simPsigDescInsDelayType,
+ simPsigDescInsDelay,
+ simPsigDescPrivDataSpfier,
+ simPsigDescInsEntryStatus,
+ simPsigDescInsDescIndex,
+ simPsigDescInsDescAdminState,
+ simPsigDescInsDescriptor,
+ simPsigDescInsDescriptorStatus,
+ simPsigDescInsDescEntryStatus,
+ simPsigTblProvIndex,
+ simPsigTblProvTableId ,
+ simPsigTblNetworkId,
+ simPsigTblONetworkId ,
+ simPsigTblTransStreamId ,
+ simPsigTblServiceId ,
+ simPsigTblBouquetId,
+ simPsigTblEventId ,
+ simPsigTblNetworkIdOther,
+ simPsigTblONetworkId2loop,
+ simPsigTblTransStreamId2OrO,
+ simPsigTblSegmentNr,
+ simPsigTblProvPart,
+ simPsigTblProvPartNumber,
+ simPsigPIDProvFlowType,
+ simPsigPIDProvSuCasId,
+ simPsigPIDProvFlowId,
+ simPsigPIDProvFlowPID,
+ simPsigPdTrNetworkId,
+ simPsigPdTrONetworkId,
+ simPsigPdTrTransStreamId,
+ simPsigPdTrServiceId,
+ simPsigPdTrEsId,
+ simPsigPdTrType,
+ simPsigPdTrSuCasId,
+ simPsigPdTrPdId,
+ simPsigPdTrPdPid,
+ simPsigPdTrPdStreamType,
+ simPsigPdTrPrivateData
+ }
+ STATUS current
+ DESCRIPTION
+"A collection of objects providing (P)SIG) infomation."
+ ::= { simGroups 6 }
+
+END