summaryrefslogtreecommitdiff
path: root/MIBS/asentria/SITEBOSS-571-STD-MIB
diff options
context:
space:
mode:
Diffstat (limited to 'MIBS/asentria/SITEBOSS-571-STD-MIB')
-rw-r--r--MIBS/asentria/SITEBOSS-571-STD-MIB18303
1 files changed, 18303 insertions, 0 deletions
diff --git a/MIBS/asentria/SITEBOSS-571-STD-MIB b/MIBS/asentria/SITEBOSS-571-STD-MIB
new file mode 100644
index 0000000..5f091cf
--- /dev/null
+++ b/MIBS/asentria/SITEBOSS-571-STD-MIB
@@ -0,0 +1,18303 @@
+-- SiteBoss 571 MIB
+
+-- v 1.44 December 30 2014
+
+-- Copyright (c) 2014 by Asentria Corporation. All rights reserved.
+
+
+SITEBOSS-571-STD-MIB DEFINITIONS ::= BEGIN
+
+IMPORTS
+ DisplayString
+ FROM SNMPv2-TC
+ IpAddress, TimeTicks, Integer32,
+ MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-TYPE
+ FROM SNMPv2-SMI
+ asentria
+ FROM ASENTRIA-ROOT-MIB;
+
+--***************************************************************************************
+--MODULE IDENTITY
+--***************************************************************************************
+
+ s571 MODULE-IDENTITY
+ LAST-UPDATED "201412300144Z"
+ ORGANIZATION "Asentria Corporation"
+ CONTACT-INFO
+ "Phone: 206-344-8800
+ Fax: 206-344-2116
+ Email: support@asentria.com"
+ DESCRIPTION
+ "MIB module for managing Asentria SiteBoss 571"
+
+ REVISION "201412300144Z"
+ DESCRIPTION
+ "-v1.44
+ -Removed wirelessPIN and scSecret objects (OMX-1064).
+ -Applicable since unit version 2.10.610."
+
+ REVISION "201412110143Z"
+ DESCRIPTION
+ "-v1.43
+ -Changed analog-input fuel sensor objects from Integer32 to DisplayString (OMX-1177).
+ -Added missing ipv6DefaultRouter object (OMX-1175).
+ -Applicable since unit version 2.10.580."
+
+ REVISION "201410160142Z"
+ DESCRIPTION
+ "-v1.42
+ -Added espcAIDisplayFormat object (OMX-1112).
+ -Removed espcAIPolarity, espcAIConvHighSign, espcAIConvLowSign objects (OMX-1113).
+ -Applicable since unit version 2.10.460."
+
+ REVISION "201410030141Z"
+ DESCRIPTION
+ "-v1.41
+ -Changed analog input objects from Integer32 to DisplayString.
+ -Applicable since unit version 2.10.460."
+
+ REVISION "201408140140Z"
+ DESCRIPTION
+ "-v1.40
+ -Fixed description for wirelessConnIP objects (OMX-1061).
+ -Applicable since unit version 2.10.390."
+
+ REVISION "201407030139Z"
+ DESCRIPTION
+ "-v1.39
+ -Fixed wirelessIdleTimeout (OMX-1037).
+ -Fixed CPE status objects (OMX-1036).
+ -Applicable since unit version 2.10.390."
+
+ REVISION "201406240138Z"
+ DESCRIPTION
+ "-v1.38
+ -Fixed CPE status objects.
+ -Applicable since unit version 2.10.340."
+
+ REVISION "201405290137Z"
+ DESCRIPTION
+ "-v1.37
+ -Added various missing objects (OMX-751).
+ -Added CPE objects (OMX-162).
+ -Applicable since unit version 2.10.320."
+
+ REVISION "201404110136Z"
+ DESCRIPTION
+ "-v1.36
+ -Clarified relay and power output function and documentation (OMX-926).
+ -Applicable since unit version 2.10.300."
+
+ REVISION "201401170135Z"
+ DESCRIPTION
+ "-v1.35
+ -Added IPv6 objects (OMX-705).
+ -Added power distribution objects (powerDistributionStatus branch) (OMX-708).
+ -Fixed ipRestrictionMask wrong type (OMX-743).
+ -Added ftpPushPermissions (OMX-737).
+ -Added snmpProxy objects (OMX-747).
+ -Applicable since unit version 2.10.150."
+
+ REVISION "201312040134Z"
+ DESCRIPTION
+ "-v1.34
+ -Added fsGenEnable (OMX-661).
+ -Applicable since unit version 2.10.110."
+
+ REVISION "201309040133Z"
+ DESCRIPTION
+ "-v1.33
+ -Added pdSystemCurrent and pdSystemPower objects (OMX-527).
+ -Added pdnDeviceCurrentValue and pdnDeviceCurrentValueStr objects (OMX-528).
+ -Applicable since unit version 2.09.626."
+
+ REVISION "201308010132Z"
+ DESCRIPTION
+ "-v1.32
+ -Added missing trapEventTypeNumber available values in description (OMX-437).
+ -Applicable since unit version 2.09.560."
+
+ REVISION "201307170131Z"
+ DESCRIPTION
+ "-v1.31
+ -Corrected snmpPBufferAllPeriod object.
+ -Applicable since unit version 2.09.560."
+
+ REVISION "201307020130Z"
+ DESCRIPTION
+ "-v1.30
+ -Added snmpPoll objects (OMX-394).
+ -Applicable since unit version 2.09.560."
+
+ REVISION "201306280129Z"
+ DESCRIPTION
+ "-v1.29
+ -Removed Ethernet Expansion card objects.
+ -Applicable since unit version 2.09.540."
+
+ REVISION "201306130128Z"
+ DESCRIPTION
+ "-v1.28
+ -Added sysFileTransfer and sysUpdate objects. (OMX-42)
+ -Applicable since unit version 2.09.520."
+
+ REVISION "201306120127Z"
+ DESCRIPTION
+ "-v1.27
+ -Renamed EX10 to Ethernet Expansion (OMX-364)
+ -Applicable since unit version 2.09.510."
+
+ REVISION "201305280126Z"
+ DESCRIPTION
+ "-v1.26
+ -Fixed incorrect SYNTAX for sysCharMask (OMX-328).
+ -Applicable since unit version 2.09.380."
+
+ REVISION "201305100125Z"
+ DESCRIPTION
+ "-v1.25
+ -Fixed incorrect SYNTAX statements for various objects (OMX-314).
+ -Applicable since unit version 2.09.380."
+
+ REVISION "201303150124Z"
+ DESCRIPTION
+ "-v1.24
+ -Renamed sysLocation branch to sysLoc (OMX-198).
+ -Applicable since unit version 2.09.240."
+
+ REVISION "201302060123Z"
+ DESCRIPTION
+ "-v1.23
+ -Added ex10 branch.
+ -Renamed telnet* objects.
+ -Applicable since unit version 2.09.240."
+
+ REVISION "201301140122Z"
+ DESCRIPTION
+ "-v1.22
+ -Added evReset branch and associated notification (OMX-83).
+ -Applicable since unit version 2.09.220."
+
+ REVISION "201211260121Z"
+ DESCRIPTION
+ "-v1.21
+ -Fixed backwards pppRoutingEnable/ethRoutingEnable comments. (BN 4620)"
+
+ REVISION "201208220120Z"
+ DESCRIPTION
+ "-v1.20
+ -Added additional AC power monitor items."
+
+ REVISION "201207090119Z"
+ DESCRIPTION
+ "-v1.19
+ -Removed wirelessBand object.
+ -Removed secSSH objects."
+
+ REVISION "201206120118Z"
+ DESCRIPTION
+ "-v1.18
+ -Removed user credentials objects.
+ -Added combined power distributor status objects."
+
+ REVISION "201204090117Z"
+ DESCRIPTION
+ "-v1.17
+ -Added eth2WanRoutingEnable object."
+
+ REVISION "201204050116Z"
+ DESCRIPTION
+ "-v1.16
+ -Added combined eventsensor status objects."
+
+ REVISION "201203060115Z"
+ DESCRIPTION
+ "-v1.15
+ -Added objects and trap definitions for fuel sensor and AC power monitor."
+
+ REVISION "201112050900Z"
+ DESCRIPTION
+ "-v1.14
+ -Added s571StockScriptTrap notification definition."
+
+ REVISION "201110240900Z"
+ DESCRIPTION
+ "-v1.13
+ -Added s571StockLoadSheddingTrap notification definition."
+
+ REVISION "201108080900Z"
+ DESCRIPTION
+ "-v1.12
+ -Added s571StockOutputTrap notification definition."
+
+ REVISION "201108010900Z"
+ DESCRIPTION
+ "-v1.11
+ -Added evMgmtReprocess object."
+
+ REVISION "201107200900Z"
+ DESCRIPTION
+ "-v1.10
+ -Added aisgStatus branch."
+
+ REVISION "201107080900Z"
+ DESCRIPTION
+ "-v1.09
+ -Added wirelessModemStatus branch."
+
+ REVISION "201101050900Z"
+ DESCRIPTION
+ "-v1.08
+ -Added espcCCNormalThreshold object."
+
+ REVISION "201012010900Z"
+ DESCRIPTION
+ "-v1.07
+ -Added support for PowerBoss external power distributors. This is in the
+ pdNextGen object branch which also supports the internal power distributor
+ of the SiteBoss 571. The old SNMP support for the internal power
+ distributor is kept in the older sub-branches of the powerDistributionStatus
+ branch (pdConfig, pdMain, pdOutput). The idea behind the pdNextGen object
+ branch is that there are 31 items for power monitoring and alarming, and
+ these items are organized in a double-indexed SNMP table object: the first
+ index is for the power distributor (and has the same numbering scheme as an
+ EventSensor -- like esIndexES, but is called pdnIndexPD), and the second
+ index is the power output to which the item applies (or just '1' if the item
+ is not specific to a particular power output). E.g., to read the main
+ current of the internal power distributor, you can use the old object
+ (pdMainCurrentValue.0) or you can use the new object
+ (pdnMainCurrentValue.200.1). To read the fuse event state of power output
+ number 8 on the power distributor (PowerBoss) at index 2, read
+ pdnOutputFuseInEventState.2.8."
+
+ REVISION "201011030900Z"
+ DESCRIPTION
+ "-v1.06
+ -Changed deadband, threshold, and current values for temperature
+ sensors from integer to floating-point type. This means the
+ SNMP object type for the temperature settings (deadbands and
+ thresholds) changed from Integer32 to DisplayString.
+ -Fixed bug where SNMP integer range defined in the MIB for
+ trapIncludedValue was 16-bit instead of 32-bit."
+
+ REVISION "201008240900Z"
+ DESCRIPTION
+ "-v1.05
+ -Fixed bug where some stock traps had too few varbinds declared.
+ -Removed useless trap definitions."
+
+ REVISION "201003170900Z"
+ DESCRIPTION
+ "-v1.04
+ -Removed useless object consoleInlineHsk.
+ -Added asset management object branch.
+ -Added altitude location object.
+ -Removed all obsolete switch references, made everything consistent
+ on outputs (relay outputs or power outputs).
+ -Added threshold objects for power distribution sensors.
+ -Added pdOutputCurrentValue object.
+ -Fixed description for pdOutputCurrentInEventState."
+
+ REVISION "201001190900Z"
+ DESCRIPTION
+ "-v1.03
+ -Increased range for esPointValueInt"
+
+ REVISION "200910080900Z"
+ DESCRIPTION
+ "-v1.02
+ -Incremental pre-release changes"
+
+ REVISION "200910050900Z"
+ DESCRIPTION
+ "-v1.01
+ -Incremental pre-release changes"
+
+ REVISION "200909170900Z"
+ DESCRIPTION
+ "-v1.00
+ -Initial version."
+
+ ::= { asentria 14 }
+ --1.3.6.1.4.1.3052.14
+
+
+
+--***************************************************************************************
+--Concise MIB View: Top Level Branches
+--***************************************************************************************
+
+-- status .1
+-- eventSensorStatus .1.1
+-- esPointTable .1.1.1
+-- dataEventStatus .1.2
+-- deStatusTable .1.2.1
+-- modemStatus .1.3
+-- modemCLIDLogTable .1.4
+-- powerDistributionStatus .1.5
+-- fuelSensorStatus .1.6
+-- fsStatusTable .1.6.1
+-- wirelessModemStatus .1.7
+-- acPowerMonitorStatus .1.8
+-- acpmStatusTable .1.8.1
+-- aisgStatus .1.9
+-- config .2
+-- eventSensorBasics .2.1
+-- esNumberEventSensors .2.1.1
+-- esTable .2.1.2
+-- esNewSensors .2.1.3
+-- eventSensorPointConfig .2.2
+-- esPointConfigTempTable .2.2.1
+-- esPointConfigCCTable .2.2.2
+-- esPointConfigHumidTable .2.2.3
+-- esPointConfigAITable .2.2.5
+-- esPointConfigOutputTable .2.2.6
+-- serialPorts .2.3
+-- numberPorts .2.3.1
+-- portConfigTable .2.3.2
+-- network .2.4
+-- interface .2.4.1
+-- defaultRouter .2.4.2
+-- dnsTable .2.4.3
+-- hostname .2.4.4
+-- hostTable .2.4.5
+-- ncpDuplex .2.4.6
+-- ncpTimeout .2.4.7
+-- snmp .2.4.8
+-- ftpPush .2.4.9
+-- ppp .2.4.10
+-- routing .2.4.11
+-- netSecurity .2.4.12
+-- rts .2.4.13
+-- trap .2.4.14
+-- routeTest .2.4.15
+-- gprs .2.4.16
+-- email .2.4.17
+-- netAdvanced .2.4.18
+-- web .2.4.19
+-- ipv6 .2.4.21
+-- cpe .2.4.22
+-- modem .2.5
+-- time .2.8
+-- clock .2.8.1
+-- console .2.10
+-- unitSecurity .2.11
+-- secCore .2.11.1
+-- secUserTable .2.11.2
+-- secFactory .2.11.3
+-- secVPN .2.11.5
+-- event .2.12
+-- evCore .2.12.1
+-- evData .2.12.2
+-- evNoData1 .2.12.3
+-- evNoData2 .2.12.4
+-- evSched1 .2.12.5
+-- evSched2 .2.12.6
+-- evShskLowTable .2.12.7
+-- evShskHighTable .2.12.8
+-- evNoSensor .2.12.9
+-- fuelSensor .2.12.11
+-- fuelSensorGeneralTable .2.12.11.1
+-- fuelSensorTankTable .2.12.11.2
+-- fuelSensorCustomTankTable .2.12.11.3
+-- fuelSensorVolumeTable .2.12.11.4
+-- fuelSensorDisconnectTable .2.12.11.5
+-- acPowerMonitor .2.12.12
+-- evReset .2.12.16
+-- action .2.14
+-- actionCallNumberTable .2.14.1
+-- actionPagerTable .2.14.2
+-- actionSched .2.14.3
+-- actionAsentria .2.14.4
+-- actionHostTable .2.14.6
+-- actionEmailTable .2.14.7
+-- actionParseError .2.14.8
+-- sys .2.16
+-- sysTime .2.16.1
+-- sysPT .2.16.2
+-- sysMTU .2.16.3
+-- sysAnswerString .2.16.4
+-- sysEventFileID .2.16.6
+-- sysEscapeCharacter .2.16.7
+-- sysTimeStamp .2.16.8
+-- sysLog .2.16.9
+-- sysCRDB .2.16.10
+-- sysCharMask .2.16.11
+-- sysPrompt .2.16.12
+-- sysBootStatus .2.16.13
+-- sysLoc .2.16.14
+-- sysAssetMgmt .2.16.15
+-- sysFileTransfer .2.16.17
+-- sysUpdate .2.16.18
+-- auditLog .2.17
+-- scripting .2.18
+-- scrGlobalEnable .2.18.1
+-- scrDTRCtrlPortEnableTable .2.18.2
+-- scrTable .2.18.3
+-- scrVolatileStringTable .2.18.4
+-- scrVolatileIntTable .2.18.5
+-- scrNonVolatileStringTable .2.18.6
+-- scrNonVolatileIntTable .2.18.7
+-- productIds .3
+-- siteName 3.1
+-- thisProduct .3.2
+-- stockTrapString .3.3
+-- trapEventTypeNumber .3.4
+-- trapEventTypeName .3.5
+-- trapIncludedValue .3.6
+-- trapIncludedString .3.7
+-- trapTypeString .3.8
+-- trapEventClassNumber .3.9
+-- trapEventClassName .3.10
+-- keyInterface .4.0
+
+--***************************************************************************************
+--Complete MIB View: All Objects
+--***************************************************************************************
+
+-- status .1
+-- eventSensorStatus .1.1
+-- esPointTable .1.1.1
+-- esPointEntry .1.1.1.1
+-- esIndexES .1.1.1.1.1
+-- esIndexPC .1.1.1.1.2
+-- esIndexPoint .1.1.1.1.3
+-- esPointName .1.1.1.1.4
+-- esPointInEventState .1.1.1.1.5
+-- esPointValueInt .1.1.1.1.6
+-- esPointValueStr .1.1.1.1.7
+-- esPointTimeLastChange .1.1.1.1.8
+-- esPointTimetickLastChange .1.1.1.1.9
+-- dataEventStatus .1.2
+-- deStatusTable .1.2.1
+-- deStatusEntry .1.2.1.1
+-- deStatusIndex .1.2.1.1.1
+-- deStatusName .1.2.1.1.2
+-- deStatusCounter .1.2.1.1.3
+-- deStatusThreshold .1.2.1.1.4
+-- modemStatus .1.3
+-- modemCLIDLogTable .1.4
+-- modemCLIDLogEntry .1.4.1
+-- modemCLIDLogIndex .1.4.1.1
+-- modemCLIDLogNumber .1.4.1.2
+-- powerDistributionStatus .1.5
+-- pdConfig .1.5.1
+-- pdMain .1.5.2
+-- pdMainCurrent .1.5.2.1
+-- pdMainCurrentInEventState .1.5.2.1.2
+-- pdMainCurrentValue .1.5.2.1.3
+-- pdMainCurrentValueStr .1.5.2.1.4
+-- pdMainCurrentDeadband .1.5.2.1.10
+-- pdMainCurrentVHighCurrent .1.5.2.1.11
+-- pdMainCurrentHighCurrent .1.5.2.1.12
+-- pdMainCurrentLowCurrent .1.5.2.1.13
+-- pdMainCurrentVLowCurrent .1.5.2.1.14
+-- pdMainVoltage .1.5.2.2
+-- pdMainVoltageInEventState .1.5.2.2.2
+-- pdMainVoltageValue .1.5.2.2.3
+-- pdMainVoltageValueStr .1.5.2.2.4
+-- pdMainVoltageDeadband .1.5.2.2.10
+-- pdMainVoltageVHighVoltage .1.5.2.2.11
+-- pdMainVoltageHighVoltage .1.5.2.2.12
+-- pdMainVoltageLowVoltage .1.5.2.2.13
+-- pdMainVoltageVLowVoltage .1.5.2.2.14
+-- pdMainPower .1.5.2.3
+-- pdMainPowerValue .1.5.2.3.3
+-- pdMainPowerValueStr .1.5.2.3.4
+-- pdOutput .1.5.3
+-- pdOutputCurrentTable .1.5.3.1
+-- pdOutputCurrentEntry .1.5.3.1.1
+-- pdOutputCurrentIndex .1.5.3.1.1.1
+-- pdOutputCurrentInEventState .1.5.3.1.1.2
+-- pdOutputCurrentValue .1.5.3.1.1.3
+-- pdOutputCurrentValueStr .1.5.3.1.1.4
+-- pdOutputCurrentDeadband .1.5.3.1.1.10
+-- pdOutputCurrentVHighCurrent .1.5.3.1.1.11
+-- pdOutputCurrentHighCurrent .1.5.3.1.1.12
+-- pdOutputCurrentLowCurrent .1.5.3.1.1.13
+-- pdOutputCurrentVLowCurrent .1.5.3.1.1.14
+-- pdOutputFuseTable .1.5.3.4
+-- pdOutputFuseEntry .1.5.3.4.1
+-- pdOutputFuseIndex .1.5.3.4.1.1
+-- pdOutputFuseInEventState .1.5.3.4.1.2
+-- pdOutputFuseValueStr .1.5.3.4.1.4
+-- pdNextGen .1.5.4
+-- pdnTable .1.5.4.1
+-- pdnEntry .1.5.4.1.1
+-- pdnIndexPD .1.5.4.1.1.1
+-- pdnIndexOutput .1.5.4.1.1.2
+-- pdnConfig .1.5.4.1.1.3
+-- pdnMainCurrentInEventState .1.5.4.1.1.4
+-- pdnMainCurrentValue .1.5.4.1.1.5
+-- pdnMainCurrentValueStr .1.5.4.1.1.6
+-- pdnMainCurrentDeadband .1.5.4.1.1.7
+-- pdnMainCurrentVHighCurrent .1.5.4.1.1.8
+-- pdnMainCurrentHighCurrent .1.5.4.1.1.9
+-- pdnMainCurrentLowCurrent .1.5.4.1.1.10
+-- pdnMainCurrentVLowCurrent .1.5.4.1.1.11
+-- pdnMainVoltageInEventState .1.5.4.1.1.12
+-- pdnMainVoltageValue .1.5.4.1.1.13
+-- pdnMainVoltageValueStr .1.5.4.1.1.14
+-- pdnMainVoltageDeadband .1.5.4.1.1.15
+-- pdnMainVoltageVHighVoltage .1.5.4.1.1.16
+-- pdnMainVoltageHighVoltage .1.5.4.1.1.17
+-- pdnMainVoltageLowVoltage .1.5.4.1.1.18
+-- pdnMainVoltageVLowVoltage .1.5.4.1.1.19
+-- pdnMainPowerValue .1.5.4.1.1.20
+-- pdnMainPowerValueStr .1.5.4.1.1.21
+-- pdnOutputCurrentInEventState .1.5.4.1.1.22
+-- pdnOutputCurrentValue .1.5.4.1.1.23
+-- pdnOutputCurrentValueStr .1.5.4.1.1.24
+-- pdnOutputCurrentDeadband .1.5.4.1.1.25
+-- pdnOutputCurrentVHighCurrent .1.5.4.1.1.26
+-- pdnOutputCurrentHighCurrent .1.5.4.1.1.27
+-- pdnOutputCurrentLowCurrent .1.5.4.1.1.28
+-- pdnOutputCurrentVLowCurrent .1.5.4.1.1.29
+-- pdnOutputFuseInEventState .1.5.4.1.1.30
+-- pdnOutputFuseValueStr .1.5.4.1.1.31
+-- pdnMainCombinedStatus .1.5.4.1.1.32
+-- pdnOutputCombinedStatusBlock1 .1.5.4.1.1.33
+-- pdnOutputCombinedStatusBlock2 .1.5.4.1.1.34
+-- pdnDeviceCurrentValue .1.5.4.1.1.35
+-- pdnDeviceCurrentValueStr .1.5.4.1.1.36
+-- pdSystem .1.5.5
+-- pdSystemCurrent .1.5.5.1
+-- pdSystemPower .1.5.5.2
+-- fuelSensorStatus .1.6
+-- fsStatusTable .1.6.1
+-- fsStatusEntry .1.6.1.1
+-- fsStatusIndex .1.6.1.1.1
+-- fsStatusName .1.6.1.1.2
+-- fsStatusDeviceState .1.6.1.1.3
+-- fsStatusVolumeValueString .1.6.1.1.4
+-- fsStatusVolumePercentLevel .1.6.1.1.7
+-- fsStatusVolumeInEventState .1.6.1.1.8
+-- fsStatusCombined .1.6.1.1.9
+-- wirelessModemStatus .1.7
+-- wmsStatus .1.7.1
+-- wmsSignal .1.7.2
+-- wmsRSSI .1.7.3
+-- wmsBER .1.7.4
+-- wmsUpdated .1.7.5
+-- wmsRegistration .1.7.6
+-- wmsLAC .1.7.7
+-- wmsCellID .1.7.8
+-- wmsIMSI .1.7.9
+-- wmsPhnum .1.7.10
+-- wmsLocalIP .1.7.11
+-- wmsMgfID .1.7.12
+-- wmsModelID .1.7.13
+-- wmsIMEI .1.7.14
+-- wmsRevID .1.7.15
+-- wmsNetName .1.7.16
+-- wmsGPRSStatus .1.7.17
+-- wmsBand .1.7.18
+-- wmsChannel .1.7.19
+-- wmsCountryCode .1.7.20
+-- wmsNetCode .1.7.21
+-- wmsPLMNColor .1.7.22
+-- wmsBScolor .1.7.23
+-- wmsMpRACH .1.7.24
+-- wmsMinRxLevel .1.7.25
+-- wmsBaseCoeff .1.7.26
+-- wmsSIMStatus .1.7.27
+-- wmsICCID .1.7.28
+-- wmsModemType .1.7.29
+-- acPowerMonitorStatus .1.8
+-- acpmStatusTable .1.8.1
+-- acpmStatusEntry .1.8.1.1
+-- acpmsIndex .1.8.1.1.1
+-- acpmsName .1.8.1.1.2
+-- acpmsAvgVoltageValueStr .1.8.1.1.3
+-- acpmsAvgVoltageMinStr .1.8.1.1.4
+-- acpmsAvgVoltageMaxStr .1.8.1.1.5
+-- acpmsAvgVoltageAvgStr .1.8.1.1.6
+-- acpmsAvgVoltageInEventState .1.8.1.1.7
+-- acpmsVoltagePhaseAValueStr .1.8.1.1.8
+-- acpmsVoltagePhaseBValueStr .1.8.1.1.9
+-- acpmsVoltagePhaseCValueStr .1.8.1.1.10
+-- acpmsAvgCurrentValueStr .1.8.1.1.11
+-- acpmsAvgCurrentMinStr .1.8.1.1.12
+-- acpmsAvgCurrentMaxStr .1.8.1.1.13
+-- acpmsAvgCurrentAvgStr .1.8.1.1.14
+-- acpmsAvgCurrentInEventState .1.8.1.1.15
+-- acpmsCurrentPhaseAValueStr .1.8.1.1.16
+-- acpmsCurrentPhaseBValueStr .1.8.1.1.17
+-- acpmsCurrentPhaseCValueStr .1.8.1.1.18
+-- acpmsFreqValueStr .1.8.1.1.19
+-- acpmsFreqMinStr .1.8.1.1.20
+-- acpmsFreqMaxStr .1.8.1.1.21
+-- acpmsFreqAvgStr .1.8.1.1.22
+-- acpmsFreqInEventState .1.8.1.1.23
+-- acpmsTRPValueStr .1.8.1.1.24
+-- acpmsTRPMinStr .1.8.1.1.25
+-- acpmsTRPMaxStr .1.8.1.1.26
+-- acpmsTRPAvgStr .1.8.1.1.27
+-- acpmsTRPInEventState .1.8.1.1.28
+-- acpmsRPPhaseAValueStr .1.8.1.1.29
+-- acpmsRPPhaseBValueStr .1.8.1.1.30
+-- acpmsRPPhaseCValueStr .1.8.1.1.31
+-- acpmsCombined .1.8.1.1.32
+-- acpmsTPFValueStr .1.8.1.1.33
+-- acpmsTPFMinStr .1.8.1.1.34
+-- acpmsTPFMaxStr .1.8.1.1.35
+-- acpmsTPFAvgStr .1.8.1.1.36
+-- acpmsTPFInEventState .1.8.1.1.37
+-- acpmsPFPhaseAValueStr .1.8.1.1.38
+-- acpmsPFPhaseBValueStr .1.8.1.1.39
+-- acpmsPFPhaseCValueStr .1.8.1.1.40
+-- acpmsTRcPValueStr .1.8.1.1.41
+-- acpmsTRcPMinStr .1.8.1.1.42
+-- acpmsTRcPMaxStr .1.8.1.1.43
+-- acpmsTRcPAvgStr .1.8.1.1.44
+-- acpmsRcPPhaseAValueStr .1.8.1.1.45
+-- acpmsRcPPhaseBValueStr .1.8.1.1.46
+-- acpmsRcPPhaseCValueStr .1.8.1.1.47
+-- acpmsTAPValueStr .1.8.1.1.48
+-- acpmsTAPMinStr .1.8.1.1.49
+-- acpmsTAPMaxStr .1.8.1.1.50
+-- acpmsTAPAvgStr .1.8.1.1.51
+-- acpmsAPPhaseAValueStr .1.8.1.1.52
+-- acpmsAPPhaseBValueStr .1.8.1.1.53
+-- acpmsAPPhaseCValueStr .1.8.1.1.54
+-- acpmsTotalEnergyWh .1.8.1.1.55
+-- acpmsTotalEnergyVAR .1.8.1.1.56
+-- acpmsTotalEnergyVA .1.8.1.1.57
+-- aisgStatus .1.9
+-- aisgsPower .1.9.1
+-- aisgsBaseStationID .1.9.2
+-- aisgsALDTable .1.9.3
+-- aisgsALDEntry .1.9.3.1
+-- aisgsALDIndex .1.9.3.1.1
+-- aisgsALDSectorID .1.9.3.1.2
+-- aisgsALDType .1.9.3.1.3
+-- aisgsALDDescription .1.9.3.1.4
+-- aisgsALDStatus .1.9.3.1.5
+-- aisgsALDID .1.9.3.1.6
+-- aisgsALDTilt .1.9.3.1.7
+-- aisgsALDHwVersion .1.9.3.1.8
+-- aisgsALDSwVersion .1.9.3.1.9
+-- aisgsALDModel .1.9.3.1.10
+-- aisgsALDAntennaModel .1.9.3.1.11
+-- aisgsALDMinTilt .1.9.3.1.12
+-- aisgsALDMaxTilt .1.9.3.1.13
+-- aisgsALDAISGVersion .1.9.3.1.14
+-- aisgsFileTable .1.9.4
+-- aisgsFileEntry .1.9.4.1
+-- aisgsFileIndex .1.9.4.1.1
+-- aisgsFileName .1.9.4.1.2
+-- aisgsFileType .1.9.4.1.3
+-- aisgsFileVersion .1.9.4.1.4
+-- aisgsAutoTable .1.9.5
+-- aisgsAutoEntry .1.9.5.1
+-- aisgsAutoIndex .1.9.5.1.1
+-- aisgsAutoVendor .1.9.5.1.2
+-- aisgsAutoALDModel .1.9.5.1.3
+-- aisgsAutoSoftware .1.9.5.1.4
+-- aisgsAutoConfig .1.9.5.1.5
+-- aisgsAutoTilt .1.9.5.1.6
+-- aisgsAAATable .1.9.6
+-- aisgsAAAEntry .1.9.6.1
+-- aisgsAAAIndex .1.9.6.1.1
+-- aisgsAAAALDID .1.9.6.1.2
+-- aisgsAAAAntennaSN .1.9.6.1.3
+-- aisgsAAASectorID .1.9.6.1.4
+
+-- config .2
+-- eventSensorBasics .2.1
+-- esNumberEventSensors .2.1.1
+-- esTable .2.1.2
+-- esEntry .2.1.2.1
+-- esIndex .2.1.2.1.1
+-- esName .2.1.2.1.2
+-- esID .2.1.2.1.3
+-- esNumberTempSensors .2.1.2.1.4
+-- esTempReportingMode .2.1.2.1.5
+-- esNumberCCs .2.1.2.1.6
+-- esCCReportingMode .2.1.2.1.7
+-- esNumberHumidSensors .2.1.2.1.8
+-- esHumidReportingMode .2.1.2.1.9
+-- esNumberNoiseSensors .2.1.2.1.10
+-- esNoiseReportingMode .2.1.2.1.11
+-- esNumberAirflowSensors .2.1.2.1.12
+-- esAirflowReportingMode .2.1.2.1.13
+-- esNumberAnalog .2.1.2.1.14
+-- esAnalogReportingMode .2.1.2.1.15
+-- esNumberOutputs .2.1.2.1.16
+-- esOutputReportingMode .2.1.2.1.17
+-- esTempCombinedStatus .2.1.2.1.18
+-- esCCCombinedStatusBlock1 .2.1.2.1.19
+-- esCCCombinedStatusBlock2 .2.1.2.1.20
+-- esCCCombinedStatusBlock3 .2.1.2.1.21
+-- esCCCombinedStatusBlock4 .2.1.2.1.22
+-- esCCCombinedStatusBlock5 .2.1.2.1.23
+-- esCCCombinedStatusBlock6 .2.1.2.1.24
+-- esCCCombinedStatusBlock7 .2.1.2.1.25
+-- esCCCombinedStatusBlock8 .2.1.2.1.26
+-- esHumidCombinedStatus .2.1.2.1.27
+-- esAnalogCombinedStatusBlock1 .2.1.2.1.28
+-- esAnalogCombinedStatusBlock2 .2.1.2.1.29
+-- esAnalogCombinedStatusBlock3 .2.1.2.1.30
+-- esAnalogCombinedStatusBlock4 .2.1.2.1.31
+-- esAnalogCombinedStatusBlock5 .2.1.2.1.32
+-- esAnalogCombinedStatusBlock6 .2.1.2.1.33
+-- esOutputCombinedStatusBlock1 .2.1.2.1.34
+-- esOutputCombinedStatusBlock2 .2.1.2.1.35
+-- esNewSensors .2.1.3
+-- eventSensorPointConfig .2.2
+-- esPointConfigTempTable .2.2.1
+-- esPointConfigTempEntry .2.2.1.1
+-- espcTempIndexES .2.2.1.1.1
+-- espcTempIndexPoint .2.2.1.1.2
+-- espcTempEnable .2.2.1.1.3
+-- espcTempScale .2.2.1.1.4
+-- espcTempDeadband .2.2.1.1.5
+-- espcTempVHighTemp .2.2.1.1.6
+-- espcTempVHighActions .2.2.1.1.7
+-- espcTempVHighTrapnum .2.2.1.1.8
+-- espcTempVHighClass .2.2.1.1.9
+-- espcTempHighTemp .2.2.1.1.10
+-- espcTempHighActions .2.2.1.1.11
+-- espcTempHighTrapnum .2.2.1.1.12
+-- espcTempHighClass .2.2.1.1.13
+-- espcTempNormalActions .2.2.1.1.14
+-- espcTempNormalTrapnum .2.2.1.1.15
+-- espcTempNormalClass .2.2.1.1.16
+-- espcTempLowTemp .2.2.1.1.17
+-- espcTempLowActions .2.2.1.1.18
+-- espcTempLowTrapnum .2.2.1.1.19
+-- espcTempLowClass .2.2.1.1.20
+-- espcTempVLowTemp .2.2.1.1.21
+-- espcTempVLowActions .2.2.1.1.22
+-- espcTempVLowTrapnum .2.2.1.1.23
+-- espcTempVLowClass .2.2.1.1.24
+-- esPointConfigCCTable .2.2.2
+-- esPointConfigCCEntry .2.2.2.1
+-- espcCCIndexES .2.2.2.1.1
+-- espcCCIndexPoint .2.2.2.1.2
+-- espcCCEnable .2.2.2.1.3
+-- espcCCName .2.2.2.1.4
+-- espcCCEventState .2.2.2.1.5
+-- espcCCThreshold .2.2.2.1.6
+-- espcCCEventActions .2.2.2.1.7
+-- espcCCEventTrapnum .2.2.2.1.8
+-- espcCCEventClass .2.2.2.1.9
+-- espcCCNormalActions .2.2.2.1.10
+-- espcCCNormalTrapnum .2.2.2.1.11
+-- espcCCNormalClass .2.2.2.1.12
+-- espcCCAlarmAlias .2.2.2.1.13
+-- espcCCNormalAlias .2.2.2.1.14
+-- espcCCNormalThreshold .2.2.2.1.15
+-- espcCCOverrideGlobalReminder .2.2.2.1.16
+-- espcCCReminderInterval .2.2.2.1.17
+-- esPointConfigHumidTable .2.2.3
+-- esPointConfigHumidEntry .2.2.3.1
+-- espcHumidIndexES .2.2.3.1.1
+-- espcHumidIndexPoint .2.2.3.1.2
+-- espcHumidEnable .2.2.3.1.3
+-- espcHumidDeadband .2.2.3.1.4
+-- espcHumidVHighHumid .2.2.3.1.5
+-- espcHumidVHighActions .2.2.3.1.6
+-- espcHumidVHighTrapnum .2.2.3.1.7
+-- espcHumidVHighClass .2.2.3.1.8
+-- espcHumidHighHumid .2.2.3.1.9
+-- espcHumidHighActions .2.2.3.1.10
+-- espcHumidHighTrapnum .2.2.3.1.11
+-- espcHumidHighClass .2.2.3.1.12
+-- espcHumidNormalActions .2.2.3.1.13
+-- espcHumidNormalTrapnum .2.2.3.1.14
+-- espcHumidNormalClass .2.2.3.1.15
+-- espcHumidLowHumid .2.2.3.1.16
+-- espcHumidLowActions .2.2.3.1.17
+-- espcHumidLowTrapnum .2.2.3.1.18
+-- espcHumidLowClass .2.2.3.1.19
+-- espcHumidVLowHumid .2.2.3.1.20
+-- espcHumidVLowActions .2.2.3.1.21
+-- espcHumidVLowTrapnum .2.2.3.1.22
+-- espcHumidVLowClass .2.2.3.1.23
+-- esPointConfigAITable .2.2.5
+-- esPointConfigAIEntry .2.2.5.1
+-- espcAIIndexES .2.2.5.1.1
+-- espcAIIndexPoint .2.2.5.1.2
+-- espcAIEnable .2.2.5.1.3
+-- espcAIDeadband .2.2.5.1.5
+-- espcAIVhighValue .2.2.5.1.6
+-- espcAIVhighActions .2.2.5.1.7
+-- espcAIVhighTrapnum .2.2.5.1.8
+-- espcAIVhighClass .2.2.5.1.9
+-- espcAIHighValue .2.2.5.1.10
+-- espcAIHighActions .2.2.5.1.11
+-- espcAIHighTrapnum .2.2.5.1.12
+-- espcAIHighClass .2.2.5.1.13
+-- espcAINormalActions .2.2.5.1.14
+-- espcAINormalTrapnum .2.2.5.1.15
+-- espcAINormalClass .2.2.5.1.16
+-- espcAILowValue .2.2.5.1.17
+-- espcAILowActions .2.2.5.1.18
+-- espcAILowTrapnum .2.2.5.1.19
+-- espcAILowClass .2.2.5.1.20
+-- espcAIVlowValue .2.2.5.1.21
+-- espcAIVlowActions .2.2.5.1.22
+-- espcAIVlowTrapnum .2.2.5.1.23
+-- espcAIVlowClass .2.2.5.1.24
+-- espcAIConvUnitName .2.2.5.1.25
+-- espcAIConvHighValue .2.2.5.1.26
+-- espcAIConvHighUnit .2.2.5.1.27
+-- espcAIConvLowValue .2.2.5.1.29
+-- espcAIConvLowUnit .2.2.5.1.30
+-- espcAIDisplayFormat .2.2.5.1.32
+-- esPointConfigOutputTable .2.2.6
+-- esPointConfigOutputEntry .2.2.6.1
+-- espcOutputIndexES .2.2.6.1.1
+-- espcOutputIndexPoint .2.2.6.1.2
+-- espcOutputEnable .2.2.6.1.3
+-- espcOutputActiveState .2.2.6.1.4
+-- espcOutputType .2.2.6.1.5
+-- espcOutputAliasValue .2.2.6.1.6
+-- espcOutputAliasColor .2.2.6.1.7
+-- espcOutputActiveAlias .2.2.6.1.10
+-- espcOutputActiveColor .2.2.6.1.11
+-- espcOutputActiveActions .2.2.6.1.12
+-- espcOutputActiveTrapnum .2.2.6.1.13
+-- espcOutputActiveClass .2.2.6.1.14
+-- espcOutputInactiveAlias .2.2.6.1.20
+-- espcOutputInactiveColor .2.2.6.1.21
+-- espcOutputInactiveActions .2.2.6.1.22
+-- espcOutputInactiveTrapnum .2.2.6.1.23
+-- espcOutputInactiveClass .2.2.6.1.24
+-- serialPorts .2.3
+-- numberPorts .2.3.1
+-- portConfigTable .2.3.2
+-- portConfigEntry .2.3.2.1
+-- portConfigIndex .2.3.2.1.1
+-- portConfigBaud .2.3.2.1.2
+-- portConfigDataFormat .2.3.2.1.3
+-- portConfigStripPtOutputLfs .2.3.2.1.4
+-- portConfigStripPtInputLfs .2.3.2.1.5
+-- portConfigMaskEnable .2.3.2.1.7
+-- portConfigDAEnable .2.3.2.1.8
+-- portConfigStoreAlarmsDPT .2.3.2.1.9
+-- portConfigRecordTimeout .2.3.2.1.10
+-- portConfigDataType .2.3.2.1.11
+-- portConfigEtxToCRLF .2.3.2.1.12
+-- portConfigMLREnable .2.3.2.1.13
+-- portConfigMLRStartField1Pos .2.3.2.1.14
+-- portConfigMLRStartField1Text .2.3.2.1.15
+-- portConfigMLRStartField2Pos .2.3.2.1.16
+-- portConfigMLRStartField2Text .2.3.2.1.17
+-- portConfigMLRNumLinesBefore .2.3.2.1.18
+-- portConfigMLREndDetection .2.3.2.1.19
+-- portConfigMLRLineCount .2.3.2.1.20
+-- portConfigMLREndField1Pos .2.3.2.1.21
+-- portConfigMLREndField1Text .2.3.2.1.22
+-- portConfigMLREndField2Pos .2.3.2.1.23
+-- portConfigMLREndField2Text .2.3.2.1.24
+-- portConfigMLRUseComplexRules .2.3.2.1.25
+-- portConfigBufferPT .2.3.2.1.26
+-- portConfigId .2.3.2.1.27
+-- portConfigMode .2.3.2.1.28
+-- portConfigHsk .2.3.2.1.29
+-- network .2.4
+-- interface .2.4.1
+-- ethernet .2.4.1.1
+-- ethernet1 .2.4.1.1.1
+-- eth1Mode .2.4.1.1.1.1
+-- eth1Address .2.4.1.1.1.2
+-- eth1SubnetMask .2.4.1.1.1.3
+-- eth1Router .2.4.1.1.1.4
+-- eth1VLAN .2.4.1.1.1.5
+-- eth1VLAN1 .2.4.1.1.1.5.1
+-- eth1VLAN1ID .2.4.1.1.1.5.1.1
+-- eth1VLAN1Priority .2.4.1.1.1.5.1.2
+-- eth1VLAN1Address .2.4.1.1.1.5.1.3
+-- eth1VLAN1SubnetMask .2.4.1.1.1.5.1.4
+-- eth1VLAN1Router .2.4.1.1.1.5.1.5
+-- eth1VLAN2 .2.4.1.1.1.5.2
+-- eth1VLAN2ID .2.4.1.1.1.5.2.1
+-- eth1VLAN2Priority .2.4.1.1.1.5.2.2
+-- eth1VLAN2Address .2.4.1.1.1.5.2.3
+-- eth1VLAN2SubnetMask .2.4.1.1.1.5.2.4
+-- eth1VLAN2Router .2.4.1.1.1.5.2.5
+-- eth1VLAN3 .2.4.1.1.1.5.3
+-- eth1VLAN3ID .2.4.1.1.1.5.3.1
+-- eth1VLAN3Priority .2.4.1.1.1.5.3.2
+-- eth1VLAN3Address .2.4.1.1.1.5.3.3
+-- eth1VLAN3SubnetMask .2.4.1.1.1.5.3.4
+-- eth1VLAN3Router .2.4.1.1.1.5.3.5
+-- eth1VLAN4 .2.4.1.1.1.5.4
+-- eth1VLAN4ID .2.4.1.1.1.5.4.1
+-- eth1VLAN4Priority .2.4.1.1.1.5.4.2
+-- eth1VLAN4Address .2.4.1.1.1.5.4.3
+-- eth1VLAN4SubnetMask .2.4.1.1.1.5.4.4
+-- eth1VLAN4Router .2.4.1.1.1.5.4.5
+-- eth1VLAN5 .2.4.1.1.1.5.5
+-- eth1VLAN5ID .2.4.1.1.1.5.5.1
+-- eth1VLAN5Priority .2.4.1.1.1.5.5.2
+-- eth1VLAN5Address .2.4.1.1.1.5.5.3
+-- eth1VLAN5SubnetMask .2.4.1.1.1.5.5.4
+-- eth1VLAN5Router .2.4.1.1.1.5.5.5
+-- eth1VLAN6 .2.4.1.1.1.5.6
+-- eth1VLAN6ID .2.4.1.1.1.5.6.1
+-- eth1VLAN6Priority .2.4.1.1.1.5.6.2
+-- eth1VLAN6Address .2.4.1.1.1.5.6.3
+-- eth1VLAN6SubnetMask .2.4.1.1.1.5.6.4
+-- eth1VLAN6Router .2.4.1.1.1.5.6.5
+-- eth1MAC .2.4.1.1.1.6
+-- eth1IPv6 .2.4.1.1.1.7
+-- eth1IPv6Mode .2.4.1.1.1.7.1
+-- eth1IPv6Static .2.4.1.1.1.7.2
+-- eth1IPv6StaticAddress .2.4.1.1.1.7.2.1
+-- eth1IPv6StaticRouter .2.4.1.1.1.7.2.2
+-- eth1IPv6Auto .2.4.1.1.1.7.3
+-- eth1IPv6AutoAddress1 .2.4.1.1.1.7.3.1
+-- eth1IPv6AutoAddress2 .2.4.1.1.1.7.3.2
+-- eth1IPv6AutoAddress3 .2.4.1.1.1.7.3.3
+-- eth1IPv6AutoAddress4 .2.4.1.1.1.7.3.4
+-- eth1IPv6LinkLocalAddress .2.4.1.1.1.7.4
+-- ethernet2 .2.4.1.1.2
+-- eth2Mode .2.4.1.1.2.1
+-- eth2Address .2.4.1.1.2.2
+-- eth2SubnetMask .2.4.1.1.2.3
+-- eth2Router .2.4.1.1.2.4
+-- eth2VLAN .2.4.1.1.2.5
+-- eth2VLAN1 .2.4.1.1.2.5.1
+-- eth2VLAN1ID .2.4.1.1.2.5.1.1
+-- eth2VLAN1Priority .2.4.1.1.2.5.1.2
+-- eth2VLAN1Address .2.4.1.1.2.5.1.3
+-- eth2VLAN1SubnetMask .2.4.1.1.2.5.1.4
+-- eth2VLAN1Router .2.4.1.1.2.5.1.5
+-- eth2VLAN2 .2.4.1.1.2.5.2
+-- eth2VLAN2ID .2.4.1.1.2.5.2.1
+-- eth2VLAN2Priority .2.4.1.1.2.5.2.2
+-- eth2VLAN2Address .2.4.1.1.2.5.2.3
+-- eth2VLAN2SubnetMask .2.4.1.1.2.5.2.4
+-- eth2VLAN2Router .2.4.1.1.2.5.2.5
+-- eth2VLAN3 .2.4.1.1.2.5.3
+-- eth2VLAN3ID .2.4.1.1.2.5.3.1
+-- eth2VLAN3Priority .2.4.1.1.2.5.3.2
+-- eth2VLAN3Address .2.4.1.1.2.5.3.3
+-- eth2VLAN3SubnetMask .2.4.1.1.2.5.3.4
+-- eth2VLAN3Router .2.4.1.1.2.5.3.5
+-- eth2VLAN4 .2.4.1.1.2.5.4
+-- eth2VLAN4ID .2.4.1.1.2.5.4.1
+-- eth2VLAN4Priority .2.4.1.1.2.5.4.2
+-- eth2VLAN4Address .2.4.1.1.2.5.4.3
+-- eth2VLAN4SubnetMask .2.4.1.1.2.5.4.4
+-- eth2VLAN4Router .2.4.1.1.2.5.4.5
+-- eth2VLAN5 .2.4.1.1.2.5.5
+-- eth2VLAN5ID .2.4.1.1.2.5.5.1
+-- eth2VLAN5Priority .2.4.1.1.2.5.5.2
+-- eth2VLAN5Address .2.4.1.1.2.5.5.3
+-- eth2VLAN5SubnetMask .2.4.1.1.2.5.5.4
+-- eth2VLAN5Router .2.4.1.1.2.5.5.5
+-- eth2VLAN6 .2.4.1.1.2.5.6
+-- eth2VLAN6ID .2.4.1.1.2.5.6.1
+-- eth2VLAN6Priority .2.4.1.1.2.5.6.2
+-- eth2VLAN6Address .2.4.1.1.2.5.6.3
+-- eth2VLAN6SubnetMask .2.4.1.1.2.5.6.4
+-- eth2VLAN6Router .2.4.1.1.2.5.6.5
+-- eth2MAC .2.4.1.1.2.6
+-- eth2IPv6 .2.4.1.1.2.7
+-- eth2IPv6Mode .2.4.1.1.2.7.1
+-- eth2IPv6Static .2.4.1.1.2.7.2
+-- eth2IPv6StaticAddress .2.4.1.1.2.7.2.1
+-- eth2IPv6StaticRouter .2.4.1.1.2.7.2.2
+-- eth2IPv6Auto .2.4.1.1.2.7.3
+-- eth2IPv6AutoAddress1 .2.4.1.1.2.7.3.1
+-- eth2IPv6AutoAddress2 .2.4.1.1.2.7.3.2
+-- eth2IPv6AutoAddress3 .2.4.1.1.2.7.3.3
+-- eth2IPv6AutoAddress4 .2.4.1.1.2.7.3.4
+-- eth2IPv6LinkLocalAddress .2.4.1.1.2.7.4
+-- defaultRouter .2.4.2
+-- dnsTable .2.4.3
+-- dnsEntry .2.4.3.1
+-- dnsIndex .2.4.3.1.1
+-- dnsAddress .2.4.3.1.2
+-- hostname .2.4.4
+-- hostTable .2.4.5
+-- hostEntry .2.4.5.1
+-- hostIndex .2.4.5.1.1
+-- hostDeclaration .2.4.5.1.2
+-- ncpDuplex .2.4.6
+-- ncpTimeout .2.4.7
+-- snmp .2.4.8
+-- snmpAgentEnable .2.4.8.1
+-- snmpNotificationCaptureEnable .2.4.8.5
+-- snmpNotificationCaptureFile .2.4.8.6
+-- snmpNotificationTx .2.4.8.7
+-- snmpNtfnAttempts .2.4.8.7.1
+-- snmpNtfnTimeout .2.4.8.7.2
+-- snmpNtfnCycles .2.4.8.7.3
+-- snmpNtfnSnooze .2.4.8.7.4
+-- snmpPoll .2.4.8.9
+-- snmpPMode .2.4.8.9.1
+-- snmpPBufferFile .2.4.8.9.2
+-- snmpPBufferAllPeriod .2.4.8.9.3
+-- snmpPRequestTable .2.4.8.9.4
+-- snmpPRequestEntry .2.4.8.9.4.1
+-- snmpPRequestIndex .2.4.8.9.4.1.1
+-- snmpPRequestDescription .2.4.8.9.4.1.2
+-- snmpPRequestAgent .2.4.8.9.4.1.3
+-- snmpPRequestReadcom .2.4.8.9.4.1.4
+-- snmpPRequestOID .2.4.8.9.4.1.5
+-- snmpPRequestPeriod .2.4.8.9.4.1.6
+-- snmpPRequestID .2.4.8.9.4.1.7
+-- snmpPRequestThreshold .2.4.8.9.4.1.8
+-- snmpPRequestResultStatus .2.4.8.9.4.1.10
+-- snmpPRequestResultValue .2.4.8.9.4.1.11
+-- snmpPRequestResultTime .2.4.8.9.4.1.12
+-- snmpPRequestResultType .2.4.8.9.4.1.13
+-- ftpPush .2.4.9
+-- ftpPushEnable .2.4.9.1
+-- ftpPushServer .2.4.9.2
+-- ftpPushAccount .2.4.9.5
+-- ftpPushDirectory .2.4.9.6
+-- ftpPushperiod .2.4.9.7
+-- ftpPushPushFileTable .2.4.9.8
+-- ftpPushPushFileEntry .2.4.9.8.1
+-- ftpPushPushFileIndex .2.4.9.8.1.1
+-- ftpPushPushFile .2.4.9.8.1.2
+-- ftpPushPushAudit .2.4.9.9
+-- ftpPushPushAlarms .2.4.9.10
+-- ftpPushRemoteFileTable .2.4.9.11
+-- ftpPushRemoteFileEntry .2.4.9.11.1
+-- ftpPushRemoteFileIndex .2.4.9.11.1.1
+-- ftpPushRemoteFileName .2.4.9.11.1.2
+-- ftpPushRemoteAlarmName .2.4.9.12
+-- ftpPushPassive .2.4.9.13
+-- ftpPushIncludeDate .2.4.9.14
+-- ftpPushIncludeTime .2.4.9.15
+-- ftpPushIncludeSeq .2.4.9.16
+-- ftpPushPermissions .2.4.9.17
+-- ppp .2.4.10
+-- pppDial .2.4.10.1
+-- pppDialEnable .2.4.10.1.1
+-- pppDialNumber .2.4.10.1.2
+-- pppDialIdleTimeout .2.4.10.1.5
+-- pppDialRetries .2.4.10.1.6
+-- pppDialCDTimeout .2.4.10.1.7
+-- pppDialLoginTimeout .2.4.10.1.8
+-- pppDialMdmInit .2.4.10.1.9
+-- pppDialSuggestIP .2.4.10.1.10
+-- pppDialPlainLogin .2.4.10.1.11
+-- pppHost .2.4.10.2
+-- pppHostEnable .2.4.10.2.1
+-- pppHostIdleTimeout .2.4.10.2.2
+-- pppHostLocalIP .2.4.10.2.3
+-- pppHostRemoteIP .2.4.10.2.4
+-- routing .2.4.11
+-- pppRoutingEnable .2.4.11.1
+-- ethRoutingEnable .2.4.11.2
+-- ethRoutingNATEnable .2.4.11.3
+-- routingInterface .2.4.11.4
+-- eth2WanRoutingEnable .2.4.11.5
+-- netSecurity .2.4.12
+-- ipRestriction .2.4.12.1
+-- ipRestrictionTable .2.4.12.1.1
+-- ipRestrictionEntry .2.4.12.1.1.1
+-- ipRestrictionIndex .2.4.12.1.1.1.1
+-- ipRestrictionEnable .2.4.12.1.1.1.2
+-- ipRestrictionMask .2.4.12.1.1.1.3
+-- rts .2.4.13
+-- rtsFileTable .2.4.13.1
+-- rtsFileEntry .2.4.13.1.1
+-- rtsFileIndex .2.4.13.1.1.1
+-- rtsFileMode .2.4.13.1.1.2
+-- rtsFileShowAnswer .2.4.13.1.1.3
+-- rtsFileReqXON .2.4.13.1.1.4
+-- rtsFileTimeout .2.4.13.1.1.5
+-- rtsFileEmptyClose .2.4.13.1.1.6
+-- rtsFilePushHost .2.4.13.1.1.7
+-- rtsFilePushPort .2.4.13.1.1.8
+-- rtsFilePushRetryTimer .2.4.13.1.1.9
+-- rtsAlarms .2.4.13.2
+-- rtsAlarmsMode .2.4.13.2.1
+-- rtsAlarmsShowAnswer .2.4.13.2.2
+-- rtsAlarmsReqXON .2.4.13.2.3
+-- rtsAlarmsTimeout .2.4.13.2.4
+-- rtsAlarmsEmptyClose .2.4.13.2.5
+-- rtsAlarmsPushHost .2.4.13.2.6
+-- rtsAlarmsPushPort .2.4.13.2.7
+-- rtsAlarmsPushRetryTimer .2.4.13.2.8
+-- trap .2.4.14
+-- trapInclude .2.4.14.1
+-- trapIncludeDateTime .2.4.14.1.1
+-- trapIncludeSiteName .2.4.14.1.2
+-- trapIncludeSensorID .2.4.14.1.3
+-- trapIncludeUDName .2.4.14.1.4
+-- trapIncludeUDState .2.4.14.1.5
+-- trapIncludeSourceAddress .2.4.14.1.6
+-- trapAuthFailEnable .2.4.14.2
+-- routeTest .2.4.15
+-- routeTestEnable .2.4.15.1
+-- routeTestPeriod .2.4.15.2
+-- routeTestAddressTable .2.4.15.3
+-- routeTestAddressEntry .2.4.15.3.1
+-- routeTestAddressIndex .2.4.15.3.1.1
+-- routeTestAddress .2.4.15.3.1.2
+-- wireless .2.4.16
+-- wirelessMode .2.4.16.1
+-- wirelessAPN .2.4.16.2
+-- wirelessIdleTimeout .2.4.16.3
+-- wirelessDRE .2.4.16.9
+-- wirelessPPPUsername .2.4.16.10
+-- wirelessFirewall .2.4.16.11
+-- wirelessKeepaliveThreshold .2.4.16.12
+-- wirelessPPPDebug .2.4.16.13
+-- wirelessConnectivity .2.4.16.20
+-- wirelessConnEnable .2.4.16.20.1
+-- wirelessConnCheckInterval .2.4.16.20.2
+-- wirelessConnFailThreshold .2.4.16.20.3
+-- wirelessConnIP1 .2.4.16.20.10
+-- wirelessConnIP2 .2.4.16.20.11
+-- email .2.4.17
+-- emailServer .2.4.17.1
+-- emailDomain .2.4.17.2
+-- emailAuthEnable .2.4.17.3
+-- netAdvanced .2.4.18
+-- arpFilter .2.4.18.1
+-- web .2.4.19
+-- webEnable .2.4.19.1
+-- webPort .2.4.19.1
+-- webTimeout .2.4.19.1
+-- ipv6 .2.4.21
+-- ipv6DefaultRouter .2.4.21.1
+-- cpe .2.4.22
+-- cpeTable .2.4.22.1
+-- cpeEntry .2.4.22.1.1
+-- cpeIndex .2.4.22.1.1.1
+-- cpeHost .2.4.22.1.1.2
+-- cpeName .2.4.22.1.1.3
+-- cpeDescription .2.4.22.1.1.4
+-- cpeKeepalive .2.4.22.1.1.5
+-- cpeThreshold .2.4.22.1.1.6
+-- cpeEventReminderInterval .2.4.22.1.1.7
+-- cpeKeepaliveTicks .2.4.22.1.1.20
+-- cpePingSize .2.4.22.1.1.21
+-- cpeInfoReset .2.4.22.1.1.30
+-- cpeInfoNumReq .2.4.22.1.1.31
+-- cpeInfoNumGoodResp .2.4.22.1.1.32
+-- cpeInfoNumBadResp .2.4.22.1.1.33
+-- cpeInfoNumLostResp .2.4.22.1.1.34
+-- cpeInfoPercentLoss .2.4.22.1.1.35
+-- cpeInfoPercentBad .2.4.22.1.1.36
+-- modem .2.5
+-- modemFormat .2.5.1
+-- modemInitString .2.5.2
+-- modemCallAttempts .2.5.4
+-- modemCallDelay .2.5.5
+-- modemCmdTimout .2.5.6
+-- modemGoto .2.5.7
+-- modemClid .2.5.8
+-- modemCLIDEnable .2.5.8.1
+-- modemCLIDNumberTable .2.5.8.2
+-- modemCLIDNumberEntry .2.5.8.2.1
+-- modemCLIDNumberIndex .2.5.8.2.1.1
+-- modemCLIDNumber .2.5.8.2.1.2
+-- modemTAPInitString .2.5.9
+-- modemTAP8N1 .2.5.10
+-- time .2.8
+-- clock .2.8.1
+-- console .2.10
+-- consoleDuplex .2.10.1
+-- consoleTimeout .2.10.2
+-- consoleBaud .2.10.4
+-- consoleFormat .2.10.5
+-- consoleHsk .2.10.6
+-- consoleConfirm .2.10.7
+-- unitSecurity .2.11
+-- secCore .2.11.1
+-- scShowPasswordPrompt .2.11.1.1
+-- scConsoleLoginRequired .2.11.1.2
+-- scModemLoginRequired .2.11.1.3
+-- scTelnetLoginRequired .2.11.1.4
+-- scTelnetPTLoginRequired .2.11.1.5
+-- scRTSLoginRequired .2.11.1.6
+-- scAuthMode .2.11.1.7
+-- scRightsGroup .2.11.1.8
+-- secUserTable .2.11.2
+-- secUserEntry .2.11.2.1
+-- secUserIndex .2.11.2.1.1
+-- secUserEnable .2.11.2.1.2
+-- secUserConnectVia .2.11.2.1.5
+-- secUserLoginTo .2.11.2.1.6
+-- secUserAccessFile .2.11.2.1.7
+-- secUserPTEscapeTo .2.11.2.1.9
+-- secUserPPPType .2.11.2.1.10
+-- secUserRights .2.11.2.1.11
+-- secUserEventsReadAccess .2.11.2.1.13
+-- secUserAuditReadAccess .2.11.2.1.14
+-- secUserEventsWriteAccess .2.11.2.1.16
+-- secUserAuditWriteAccess .2.11.2.1.17
+-- secUserExpiration .2.11.2.1.18
+-- secUserCallbackNumber1 .2.11.2.1.19
+-- secUserCallbackNumber2 .2.11.2.1.20
+-- secUserCallbackNumber3 .2.11.2.1.21
+-- secUserChallengeTelnetMode .2.11.2.1.22
+-- secUserChallengeModemMode .2.11.2.1.23
+-- secUserChallengeConsoleMode .2.11.2.1.24
+-- secUserChallengeTelnetSendTo .2.11.2.1.25
+-- secUserChallengeModemSendTo .2.11.2.1.26
+-- secUserChallengeExpiration .2.11.2.1.27
+-- secFactory .2.11.3
+-- sfEnable .2.11.3.1
+-- sfSecret .2.11.3.2
+-- secSSH .2.11.4
+-- secVPN .2.11.5
+-- event .2.12
+-- evCore .2.12.1
+-- evClassNameTable .2.12.1.1
+-- evClassNameEntry .2.12.1.1.1
+-- evClassNameIndex .2.12.1.1.1.1
+-- evClassName .2.12.1.1.1.2
+-- evReminderInterval .2.12.1.2
+-- evLog .2.12.1.3
+-- evLogEnable .2.12.1.3.1
+-- evLogStoreAlarm .2.12.1.3.2
+-- evLogMaxSize .2.12.1.3.3
+-- evLogStoreSensor .2.12.1.3.4
+-- evLogTimeStampAlarms .2.12.1.3.5
+-- evLogPrependName .2.12.1.3.6
+-- evMgmt .2.12.1.4
+-- evMgmtReprocess .2.12.1.4.3
+-- evData .2.12.2
+-- evdCore .2.12.2.1
+-- evdExitOnTrue .2.12.2.1.1
+-- evdFilterAction .2.12.2.1.2
+-- evdWildCardChar .2.12.2.1.3
+-- evdTable .2.12.2.2
+-- evdEntry .2.12.2.2.1
+-- evdIndex .2.12.2.2.1.1
+-- evdEnable .2.12.2.2.1.2
+-- evdName .2.12.2.2.1.3
+-- evdEquation .2.12.2.2.1.4
+-- evdThreshold .2.12.2.2.1.5
+-- evdAutoclear .2.12.2.2.1.6
+-- evdClearInterval .2.12.2.2.1.7
+-- evdClearTime .2.12.2.2.1.8
+-- evdActions .2.12.2.2.1.9
+-- evdClass .2.12.2.2.1.10
+-- evdTrapNum .2.12.2.2.1.11
+-- evdMode .2.12.2.2.1.12
+-- evdFieldTable .2.12.2.3
+-- evdFieldEntry .2.12.2.3.1
+-- evdFieldIndex .2.12.2.3.1.1
+-- evdFieldStart .2.12.2.3.1.2
+-- evdFieldLength .2.12.2.3.1.3
+-- evdFieldName .2.12.2.3.1.4
+-- evdFieldLine .2.12.2.3.1.5
+-- evdFieldType .2.12.2.3.1.6
+-- evdMacroTable .2.12.2.4
+-- evdMacroEntry .2.12.2.4.1
+-- evdMacroIndex .2.12.2.4.1.1
+-- evdMacroName .2.12.2.4.1.2
+-- evdMacroEquation .2.12.2.4.1.3
+-- evNoData1 .2.12.3
+-- evNoData1Enable .2.12.3.1
+-- evNoData1Actions .2.12.3.2
+-- evNoData1Message .2.12.3.3
+-- evNoData1TrapNum .2.12.3.4
+-- evNoData1Class .2.12.3.5
+-- evNoData1Sched1Begin .2.12.3.6
+-- evNoData1Sched1End .2.12.3.7
+-- evNoData1Sched1Duration .2.12.3.8
+-- evNoData1Sched2Begin .2.12.3.9
+-- evNoData1Sched2End .2.12.3.10
+-- evNoData1Sched2Duration .2.12.3.11
+-- evNoData1PortEnableTable .2.12.3.12
+-- evNoData1PortEnableEntry .2.12.3.12.1
+-- evNoData1PortEnableIndex .2.12.3.12.1.1
+-- evNoData1PortEnable .2.12.3.12.1.2
+-- evNoData1Exclusions .2.12.3.13
+-- evNoData1Days .2.12.3.14
+-- evNoData2 .2.12.4
+-- evNoData2Enable .2.12.4.1
+-- evNoData2Actions .2.12.4.2
+-- evNoData2Message .2.12.4.3
+-- evNoData2TrapNum .2.12.4.4
+-- evNoData2Class .2.12.4.5
+-- evNoData2Sched1Begin .2.12.4.6
+-- evNoData2Sched1End .2.12.4.7
+-- evNoData2Sched1Duration .2.12.4.8
+-- evNoData2Sched2Begin .2.12.4.9
+-- evNoData2Sched2End .2.12.4.10
+-- evNoData2Sched2Duration .2.12.4.11
+-- evNoData2PortEnableTable .2.12.4.12
+-- evNoData2PortEnableEntry .2.12.4.12.1
+-- evNoData2PortEnableIndex .2.12.4.12.1.1
+-- evNoData2PortEnable .2.12.4.12.1.2
+-- evNoData2Exclusions .2.12.4.13
+-- evNoData2Days .2.12.4.14
+-- evSched1 .2.12.5
+-- evSched1Enable .2.12.5.1
+-- evSched1Actions .2.12.5.2
+-- evSched1Message .2.12.5.3
+-- evSched1TrapNum .2.12.5.4
+-- evSched1Class .2.12.5.5
+-- evSched1Sunday .2.12.5.6
+-- evSched1Monday .2.12.5.7
+-- evSched1Tuesday .2.12.5.8
+-- evSched1Wednesday .2.12.5.9
+-- evSched1Thursday .2.12.5.10
+-- evSched1Friday .2.12.5.11
+-- evSched1Saturday .2.12.5.12
+-- evSched1Exclusions .2.12.5.13
+-- evSched2 .2.12.6
+-- evSched2Enable .2.12.6.1
+-- evSched2Actions .2.12.6.2
+-- evSched2Message .2.12.6.3
+-- evSched2TrapNum .2.12.6.4
+-- evSched2Class .2.12.6.5
+-- evSched2Sunday .2.12.6.6
+-- evSched2Monday .2.12.6.7
+-- evSched2Tuesday .2.12.6.8
+-- evSched2Wednesday .2.12.6.9
+-- evSched2Thursday .2.12.6.10
+-- evSched2Friday .2.12.6.11
+-- evSched2Saturday .2.12.6.12
+-- evSched2Exclusions .2.12.6.13
+-- evShskLowTable .2.12.7
+-- evShskLowEntry .2.12.7.1
+-- evShskLowIndex .2.12.7.1.1
+-- evShskLowEnable .2.12.7.1.2
+-- evShskLowActions .2.12.7.1.3
+-- evShskLowMessage .2.12.7.1.4
+-- evShskLowClass .2.12.7.1.5
+-- evShskLowTrapNum .2.12.7.1.6
+-- evShskHighTable .2.12.8
+-- evShskHighEntry .2.12.8.1
+-- evShskHighIndex .2.12.8.1.1
+-- evShskHighEnable .2.12.8.1.2
+-- evShskHighActions .2.12.8.1.3
+-- evShskHighMessage .2.12.8.1.4
+-- evShskHighClass .2.12.8.1.5
+-- evShskHighTrapNum .2.12.8.1.6
+-- evNoSensor .2.12.9
+-- evNoSensorTimeout .2.12.9.1
+-- evNoSensorActions .2.12.9.2
+-- evNoSensorTrapNum .2.12.9.3
+-- evNoSensorClass .2.12.9.4
+-- fuelSensor .2.12.11
+-- fuelSensorGeneralTable .2.12.11.1
+-- fsGenEntry .2.12.11.1.1
+-- fsGenIndex .2.12.11.1.1.1
+-- fsGenName .2.12.11.1.1.2
+-- fsGenSensorType .2.12.11.1.1.3
+-- fsGenDistanceUnit .2.12.11.1.1.4
+-- fsGenRawValueTop .2.12.11.1.1.5
+-- fsGenTopOffset .2.12.11.1.1.6
+-- fsGenRawValueBottom .2.12.11.1.1.7
+-- fsGenBottomOffset .2.12.11.1.1.8
+-- fsGenInputES .2.12.11.1.1.9
+-- fsGenInputPoint .2.12.11.1.1.10
+-- fsGenFilterAveraging .2.12.11.1.1.11
+-- fsGenSysrepEnable .2.12.11.1.1.12
+-- fsGenSysrepThreshold .2.12.11.1.1.13
+-- fsGenSysrepLimit .2.12.11.1.1.14
+-- fsGenSysrepPackage .2.12.11.1.1.15
+-- fsGenSysrepType .2.12.11.1.1.16
+-- fsGenEnable .2.12.11.1.1.17
+-- fuelSensorTankTable .2.12.11.2
+-- fsTankEntry .2.12.11.2.1
+-- fsTankIndex .2.12.11.2.1.1
+-- fsTankHeight .2.12.11.2.1.2
+-- fsTankDimA .2.12.11.2.1.3
+-- fsTankDimB .2.12.11.2.1.4
+-- fsTankVolume .2.12.11.2.1.5
+-- fsTankVolumeUnit .2.12.11.2.1.6
+-- fsTankShape .2.12.11.2.1.7
+-- fuelSensorCustomTankTable .2.12.11.3
+-- fsCustomTankEntry .2.12.11.3.1
+-- fsCustomTankIndexFS .2.12.11.3.1.1
+-- fsCustomTankIndexDatum .2.12.11.3.1.2
+-- fsCustomTankHeight .2.12.11.3.1.3
+-- fsCustomTankVolume .2.12.11.3.1.4
+-- fuelSensorVolumeTable .2.12.11.4
+-- fsVolumeEntry .2.12.11.4.1
+-- fsVolumeIndex .2.12.11.4.1.1
+-- fsVolumeEnable .2.12.11.4.1.2
+-- fsVolumeDeadband .2.12.11.4.1.3
+-- fsVolumeVHighValue .2.12.11.4.1.4
+-- fsVolumeVHighActions .2.12.11.4.1.5
+-- fsVolumeVHighTrapNum .2.12.11.4.1.6
+-- fsVolumeVHighClass .2.12.11.4.1.7
+-- fsVolumeHighValue .2.12.11.4.1.8
+-- fsVolumeHighActions .2.12.11.4.1.9
+-- fsVolumeHighTrapNum .2.12.11.4.1.10
+-- fsVolumeHighClass .2.12.11.4.1.11
+-- fsVolumeNormalActions .2.12.11.4.1.12
+-- fsVolumeNormalTrapNum .2.12.11.4.1.13
+-- fsVolumeNormalClass .2.12.11.4.1.14
+-- fsVolumeLowValue .2.12.11.4.1.15
+-- fsVolumeLowActions .2.12.11.4.1.16
+-- fsVolumeLowTrapNum .2.12.11.4.1.17
+-- fsVolumeLowClass .2.12.11.4.1.18
+-- fsVolumeVLowValue .2.12.11.4.1.19
+-- fsVolumeVLowActions .2.12.11.4.1.20
+-- fsVolumeVLowTrapNum .2.12.11.4.1.21
+-- fsVolumeVLowClass .2.12.11.4.1.22
+-- fuelSensorDisconnectTable .2.12.11.5
+-- fsDiscEntry .2.12.11.5.1
+-- fsDiscIndex .2.12.11.5.1.1
+-- fsDiscEnable .2.12.11.5.1.2
+-- fsDiscHighValue .2.12.11.5.1.3
+-- fsDiscLowValue .2.12.11.5.1.4
+-- fsDiscActions .2.12.11.5.1.5
+-- fsDiscTrapNum .2.12.11.5.1.6
+-- fsDiscClass .2.12.11.5.1.7
+-- fsDiscNormalActions .2.12.11.5.1.8
+-- fsDiscNormalTrapNum .2.12.11.5.1.9
+-- fsDiscNormalClass .2.12.11.5.1.10
+-- acPowerMonitor .2.12.12
+-- acpmGeneralTable .2.12.12.1
+-- acpmGenEntry .2.12.12.1.1
+-- acpmGenIndex .2.12.12.1.1.1
+-- acpmGenDevice .2.12.12.1.1.2
+-- acpmGenName .2.12.12.1.1.3
+-- acpmGenAddress .2.12.12.1.1.4
+-- acpmGenPtRatio .2.12.12.1.1.5
+-- acpmGenCtRatio .2.12.12.1.1.6
+-- acpmGenPowerType .2.12.12.1.1.7
+-- acpmGenSysrepPackage .2.12.12.1.1.8
+-- acpmGenSysrepType .2.12.12.1.1.9
+-- acpmGenEnable .2.12.12.1.1.10
+-- acpmAvgVoltageTable .2.12.12.2
+-- acpmAvgVoltageEntry .2.12.12.2.1
+-- acpmAvgVoltageIndex .2.12.12.2.1.1
+-- acpmAvgVoltageEnable .2.12.12.2.1.2
+-- acpmAvgVoltageDeadband .2.12.12.2.1.3
+-- acpmAvgVoltageVHighValue .2.12.12.2.1.4
+-- acpmAvgVoltageVHighActions .2.12.12.2.1.5
+-- acpmAvgVoltageVHighTrapNum .2.12.12.2.1.6
+-- acpmAvgVoltageVHighClass .2.12.12.2.1.7
+-- acpmAvgVoltageHighValue .2.12.12.2.1.8
+-- acpmAvgVoltageHighActions .2.12.12.2.1.9
+-- acpmAvgVoltageHighTrapNum .2.12.12.2.1.10
+-- acpmAvgVoltageHighClass .2.12.12.2.1.11
+-- acpmAvgVoltageNormalActions .2.12.12.2.1.12
+-- acpmAvgVoltageNormalTrapNum .2.12.12.2.1.13
+-- acpmAvgVoltageNormalClass .2.12.12.2.1.14
+-- acpmAvgVoltageLowValue .2.12.12.2.1.15
+-- acpmAvgVoltageLowActions .2.12.12.2.1.16
+-- acpmAvgVoltageLowTrapNum .2.12.12.2.1.17
+-- acpmAvgVoltageLowClass .2.12.12.2.1.18
+-- acpmAvgVoltageVLowValue .2.12.12.2.1.19
+-- acpmAvgVoltageVLowActions .2.12.12.2.1.20
+-- acpmAvgVoltageVLowTrapNum .2.12.12.2.1.21
+-- acpmAvgVoltageVLowClass .2.12.12.2.1.22
+-- acpmAvgVoltageSysrepEnable .2.12.12.2.1.23
+-- acpmAvgVoltageSysrepThreshold .2.12.12.2.1.24
+-- acpmAvgVoltageSysrepLimit .2.12.12.2.1.25
+-- acpmAvgCurrentTable .2.12.12.3
+-- acpmAvgCurrentEntry .2.12.12.3.1
+-- acpmAvgCurrentIndex .2.12.12.3.1.1
+-- acpmAvgCurrentEnable .2.12.12.3.1.2
+-- acpmAvgCurrentDeadband .2.12.12.3.1.3
+-- acpmAvgCurrentVHighValue .2.12.12.3.1.4
+-- acpmAvgCurrentVHighActions .2.12.12.3.1.5
+-- acpmAvgCurrentVHighTrapNum .2.12.12.3.1.6
+-- acpmAvgCurrentVHighClass .2.12.12.3.1.7
+-- acpmAvgCurrentHighValue .2.12.12.3.1.8
+-- acpmAvgCurrentHighActions .2.12.12.3.1.9
+-- acpmAvgCurrentHighTrapNum .2.12.12.3.1.10
+-- acpmAvgCurrentHighClass .2.12.12.3.1.11
+-- acpmAvgCurrentNormalActions .2.12.12.3.1.12
+-- acpmAvgCurrentNormalTrapNum .2.12.12.3.1.13
+-- acpmAvgCurrentNormalClass .2.12.12.3.1.14
+-- acpmAvgCurrentLowValue .2.12.12.3.1.15
+-- acpmAvgCurrentLowActions .2.12.12.3.1.16
+-- acpmAvgCurrentLowTrapNum .2.12.12.3.1.17
+-- acpmAvgCurrentLowClass .2.12.12.3.1.18
+-- acpmAvgCurrentVLowValue .2.12.12.3.1.19
+-- acpmAvgCurrentVLowActions .2.12.12.3.1.20
+-- acpmAvgCurrentVLowTrapNum .2.12.12.3.1.21
+-- acpmAvgCurrentVLowClass .2.12.12.3.1.22
+-- acpmAvgCurrentSysrepEnable .2.12.12.3.1.23
+-- acpmAvgCurrentSysrepThreshold .2.12.12.3.1.24
+-- acpmAvgCurrentSysrepLimit .2.12.12.3.1.25
+-- acpmFreqTable .2.12.12.4
+-- acpmFreqEntry .2.12.12.4.1
+-- acpmFreqIndex .2.12.12.4.1.1
+-- acpmFreqEnable .2.12.12.4.1.2
+-- acpmFreqDeadband .2.12.12.4.1.3
+-- acpmFreqVHighValue .2.12.12.4.1.4
+-- acpmFreqVHighActions .2.12.12.4.1.5
+-- acpmFreqVHighTrapNum .2.12.12.4.1.6
+-- acpmFreqVHighClass .2.12.12.4.1.7
+-- acpmFreqHighValue .2.12.12.4.1.8
+-- acpmFreqHighActions .2.12.12.4.1.9
+-- acpmFreqHighTrapNum .2.12.12.4.1.10
+-- acpmFreqHighClass .2.12.12.4.1.11
+-- acpmFreqNormalActions .2.12.12.4.1.12
+-- acpmFreqNormalTrapNum .2.12.12.4.1.13
+-- acpmFreqNormalClass .2.12.12.4.1.14
+-- acpmFreqLowValue .2.12.12.4.1.15
+-- acpmFreqLowActions .2.12.12.4.1.16
+-- acpmFreqLowTrapNum .2.12.12.4.1.17
+-- acpmFreqLowClass .2.12.12.4.1.18
+-- acpmFreqVLowValue .2.12.12.4.1.19
+-- acpmFreqVLowActions .2.12.12.4.1.20
+-- acpmFreqVLowTrapNum .2.12.12.4.1.21
+-- acpmFreqVLowClass .2.12.12.4.1.22
+-- acpmFreqSysrepEnable .2.12.12.4.1.23
+-- acpmFreqSysrepThreshold .2.12.12.4.1.24
+-- acpmFreqSysrepLimit .2.12.12.4.1.25
+-- acpmTotalRealPowerTable .2.12.12.5
+-- acpmTRPEntry .2.12.12.5.1
+-- acpmTRPIndex .2.12.12.5.1.1
+-- acpmTRPEnable .2.12.12.5.1.2
+-- acpmTRPDeadband .2.12.12.5.1.3
+-- acpmTRPVHighValue .2.12.12.5.1.4
+-- acpmTRPVHighActions .2.12.12.5.1.5
+-- acpmTRPVHighTrapNum .2.12.12.5.1.6
+-- acpmTRPVHighClass .2.12.12.5.1.7
+-- acpmTRPHighValue .2.12.12.5.1.8
+-- acpmTRPHighActions .2.12.12.5.1.9
+-- acpmTRPHighTrapNum .2.12.12.5.1.10
+-- acpmTRPHighClass .2.12.12.5.1.11
+-- acpmTRPNormalActions .2.12.12.5.1.12
+-- acpmTRPNormalTrapNum .2.12.12.5.1.13
+-- acpmTRPNormalClass .2.12.12.5.1.14
+-- acpmTRPLowValue .2.12.12.5.1.15
+-- acpmTRPLowActions .2.12.12.5.1.16
+-- acpmTRPLowTrapNum .2.12.12.5.1.17
+-- acpmTRPLowClass .2.12.12.5.1.18
+-- acpmTRPVLowValue .2.12.12.5.1.19
+-- acpmTRPVLowActions .2.12.12.5.1.20
+-- acpmTRPVLowTrapNum .2.12.12.5.1.21
+-- acpmTRPVLowClass .2.12.12.5.1.22
+-- acpmTRPSysrepEnable .2.12.12.5.1.23
+-- acpmTRPSysrepThreshold .2.12.12.5.1.24
+-- acpmTRPSysrepLimit .2.12.12.5.1.25
+-- acpmDisconnectTable .2.12.12.6
+-- acpmDisconnectEntry .2.12.12.6.1
+-- acpmDisconnectIndex .2.12.12.6.1.1
+-- acpmDisconnectEnable .2.12.12.6.1.2
+-- acpmDisconnectActions .2.12.12.6.1.3
+-- acpmDisconnectTrapNum .2.12.12.6.1.4
+-- acpmDisconnectClass .2.12.12.6.1.5
+-- acpmDisconnectNormalActions .2.12.12.6.1.6
+-- acpmDisconnectNormalTrapNum .2.12.12.6.1.7
+-- acpmDisconnectNormalClass .2.12.12.6.1.8
+-- acpmTotalPowerFactorTable .2.12.12.7
+-- acpmTPFEntry .2.12.12.7.1
+-- acpmTPFIndex .2.12.12.7.1.1
+-- acpmTPFEnable .2.12.12.7.1.2
+-- acpmTPFDeadband .2.12.12.7.1.3
+-- acpmTPFNormalActions .2.12.12.7.1.4
+-- acpmTPFNormalTrapNum .2.12.12.7.1.5
+-- acpmTPFNormalClass .2.12.12.7.1.6
+-- acpmTPFLowValue .2.12.12.7.1.7
+-- acpmTPFLowActions .2.12.12.7.1.8
+-- acpmTPFLowTrapNum .2.12.12.7.1.9
+-- acpmTPFLowClass .2.12.12.7.1.10
+-- acpmTPFVLowValue .2.12.12.7.1.11
+-- acpmTPFVLowActions .2.12.12.7.1.12
+-- acpmTPFVLowTrapNum .2.12.12.7.1.13
+-- acpmTPFVLowClass .2.12.12.7.1.14
+-- acpmTPFSysrepEnable .2.12.12.7.1.15
+-- acpmTPFSysrepThreshold .2.12.12.7.1.16
+-- acpmTPFSysrepLimit .2.12.12.7.1.17
+-- evReset .2.12.16
+-- evResetEnable .2.12.16.1
+-- evResetDelay .2.12.16.2
+-- evResetActions .2.12.16.3
+-- evResetMessage .2.12.16.4
+-- evResetTrapnum .2.12.16.5
+-- evResetClass .2.12.16.6
+-- action .2.14
+-- actionCallNumberTable .2.14.1
+-- actionCallNumberEntry .2.14.1.1
+-- actionCallNumberIndex .2.14.1.1.1
+-- actionCallNumber .2.14.1.1.2
+-- actionPagerTable .2.14.2
+-- actionPagerEntry .2.14.2.1
+-- actionPagerIndex .2.14.2.1.1
+-- actionPagerType .2.14.2.1.2
+-- actionPagerNumber .2.14.2.1.3
+-- actionPagerID .2.14.2.1.4
+-- actionPagerMessage .2.14.2.1.5
+-- actionPagerPostCalloutDelay .2.14.2.1.6
+-- actionPagerPostIDDelay .2.14.2.1.7
+-- actionSched .2.14.3
+-- actionSchedEnable .2.14.3.1
+-- actionSchedBegin .2.14.3.2
+-- actionSchedEnd .2.14.3.3
+-- actionSchedWeekdaysOnly .2.14.3.4
+-- actionAsentria .2.14.4
+-- actionAsentriaRequireAck .2.14.4.1
+-- actionAsentriaVersion .2.14.4.2
+-- actionAsentriaTCPPort .2.14.4.3
+-- actionHostTable .2.14.6
+-- actionHostEntry .2.14.6.1
+-- actionHostIndex .2.14.6.1.1
+-- actionHost .2.14.6.1.2
+-- actionEmailTable .2.14.7
+-- actionEmailEntry .2.14.7.1
+-- actionEmailIndex .2.14.7.1.1
+-- actionEmail .2.14.7.1.2
+-- actionParseError .2.14.8
+-- sys .2.16
+-- sysTime .2.16.1
+-- sysTimeAutoDST .2.16.1.1
+-- sysTimeGMTOffset .2.16.1.2
+-- sysTimeGMTDirection .2.16.1.3
+-- sysTimeNet .2.16.1.4
+-- sysTimeNetEnable .2.16.1.4.1
+-- sysTimeNetHostTable .2.16.1.4.2
+-- sysTimeNetHostEntry .2.16.1.4.2.1
+-- sysTimeNetHostIndex .2.16.1.4.2.1.1
+-- sysTimeNetHost .2.16.1.4.2.1.2
+-- sysPT .2.16.2
+-- sysPTTimeout .2.16.2.1
+-- sysPTEndPause .2.16.2.2
+-- sysPTJoinable .2.16.2.3
+-- sysMTU .2.16.3
+-- sysAnswerString .2.16.4
+-- sysEventFileID .2.16.6
+-- sysEscapeCharacter .2.16.7
+-- sysTimeStamp .2.16.8
+-- sysTimeStampTimeFormat .2.16.8.1
+-- sysTimeStampDateFormat .2.16.8.2
+-- sysTimeStampSpaceAfter .2.16.8.3
+-- sysLog .2.16.9
+-- sysLogMode .2.16.9.1
+-- sysLoghost .2.16.9.2
+-- sysLogFilter .2.16.9.3
+-- sysLogFileSize .2.16.9.4
+-- sysLogFileCount .2.16.9.5
+-- sysLogListenPort .2.16.9.6
+-- sysCRDB .2.16.10
+-- sysCRDBCapacity .2.16.10.1
+-- sysCRDBPercentFull .2.16.10.2
+-- sysCRDBFileIDTable .2.16.10.3
+-- sysCRDBFileIDEntry .2.16.10.3.1
+-- sysCRDBFileIDIndex .2.16.10.3.1.1
+-- sysCRDBFileID .2.16.10.3.1.2
+-- sysCRDBFileEnforceMinTable .2.16.10.4
+-- sysCRDBFileEnforceMinEntry .2.16.10.4.1
+-- sysCRDBFileEnforceMinIndex .2.16.10.4.1.1
+-- sysCRDBFileEnforceMin .2.16.10.4.1.2
+-- sysCharMask .2.16.11
+-- sysPrompt .2.16.12
+-- sysBootStatus .2.16.13
+-- sysLoc .2.16.14
+-- sysLocLatitude .2.16.14.1
+-- sysLocLongitude .2.16.14.2
+-- sysLocXOffset .2.16.14.3
+-- sysLocYOffset .2.16.14.4
+-- sysLocAngle .2.16.14.5
+-- sysLocAltitude .2.16.14.6
+-- sysAssetMgmt .2.16.15
+-- sysAMManufacturer .2.16.15.1
+-- sysAMProduct .2.16.15.2
+-- sysAMSerialNumber .2.16.15.3
+-- sysAMHardwareOptions .2.16.15.4
+-- sysAMSoftwareVersion .2.16.15.5
+-- sysAMSiteName .2.16.15.6
+-- sysFileTransfer .2.16.17
+-- sysFileTransferStatus .2.16.17.1
+-- sysFileTransferURL .2.16.17.2
+-- sysFileTransferUsername .2.16.17.3
+-- sysFileTransferPassword .2.16.17.4
+-- sysUpdate .2.16.18
+-- sysUpdateStatus .2.16.18.1
+-- auditLog .2.17
+-- auditLogEnable .2.17.1
+-- auditLogStoreResets .2.17.2
+-- auditLogStoreCommands .2.17.3
+-- auditLogStoreOutputs .2.17.4
+-- auditLogStoreAlarmActions .2.17.5
+-- auditLogStorePwdFailures .2.17.6
+-- auditLogStoreLogins .2.17.7
+-- auditLogStoreSHSK .2.17.8
+-- auditLogStorePassthrough .2.17.9
+-- auditLogStoreInactivity .2.17.10
+-- auditLogStorePolling .2.17.11
+-- auditLogMaxSize .2.17.12
+-- scripting .2.18
+-- scrGlobalEnable .2.18.1
+-- scrDTRCtrlPortEnableTable .2.18.2
+-- scrDTRCtrlPortEnableEnabletry .2.18.2.1
+-- scrDTRCtrlPortEnableIndex .2.18.2.1.1
+-- scrDTRCtrlPortEnable .2.18.2.1.2
+-- scrTable .2.18.3
+-- scrEntry .2.18.3.1
+-- scrIndex .2.18.3.1.1
+-- scrEnable .2.18.3.1.2
+-- scrName .2.18.3.1.3
+-- scrFilename .2.18.3.1.4
+-- scrRunAlways .2.18.3.1.5
+-- scrRunAtStartup .2.18.3.1.6
+-- scrRunScheduled .2.18.3.1.7
+-- scrScheduleTime .2.18.3.1.8
+-- scrArguments .2.18.3.1.9
+-- scrRepeatInterval .2.18.3.1.10
+-- scrVolatileStringTable .2.18.4
+-- scrVolatileStringEntry .2.18.4.1
+-- scrVolatileStringIndex .2.18.4.1.1
+-- scrVolatileString .2.18.4.1.2
+-- scrVolatileIntTable .2.18.5
+-- scrVolatileIntEntry .2.18.5.1
+-- scrVolatileIntIndex .2.18.5.1.1
+-- scrVolatileInt .2.18.5.1.2
+-- scrNonVolatileStringTable .2.18.6
+-- scrNonVolatileStringEntry .2.18.6.1
+-- scrNonVolatileStringIndex .2.18.6.1.1
+-- scrNonVolatileString .2.18.6.1.2
+-- scrNonVolatileIntTable .2.18.7
+-- scrNonVolatileIntEntry .2.18.7.1
+-- scrNonVolatileIntIndex .2.18.7.1.1
+-- scrNonVolatileInt .2.18.7.1.2
+
+-- productIds .3
+-- siteName 3.1
+-- thisProduct .3.2
+-- stockTrapString .3.3
+-- trapEventTypeNumber .3.4
+-- trapEventTypeName .3.5
+-- trapIncludedValue .3.6
+-- trapIncludedString .3.7
+-- trapTypeString .3.8
+-- trapEventClassNumber .3.9
+-- trapEventClassName .3.10
+
+-- keyInterface .4.0
+
+
+--***************************************************************************************
+--TOP-LEVEL OBJECT IDENTIFIERS
+--***************************************************************************************
+
+
+
+ status OBJECT IDENTIFIER ::= { s571 1 }
+ --1.3.6.1.4.1.3052.14.1
+
+ eventSensorStatus OBJECT IDENTIFIER ::= { status 1 }
+ --1.3.6.1.4.1.3052.14.1.1
+
+ dataEventStatus OBJECT IDENTIFIER ::= { status 2 }
+ --1.3.6.1.4.1.3052.14.1.2
+
+ powerDistributionStatus OBJECT IDENTIFIER ::= { status 5 }
+ --1.3.6.1.4.1.3052.14.1.5
+
+ pdMain OBJECT IDENTIFIER ::= { powerDistributionStatus 2 }
+ --1.3.6.1.4.1.3052.14.1.5.2
+
+ pdMainCurrent OBJECT IDENTIFIER ::= { pdMain 1 }
+ --1.3.6.1.4.1.3052.14.1.5.2.1
+
+ pdMainVoltage OBJECT IDENTIFIER ::= { pdMain 2 }
+ --1.3.6.1.4.1.3052.14.1.5.2.2
+
+ pdMainPower OBJECT IDENTIFIER ::= { pdMain 3 }
+ --1.3.6.1.4.1.3052.14.1.5.2.3
+
+ pdOutput OBJECT IDENTIFIER ::= { powerDistributionStatus 3 }
+ --1.3.6.1.4.1.3052.14.1.5.3
+
+ pdOutputCurrent OBJECT IDENTIFIER ::= { pdOutput 1 }
+ --1.3.6.1.4.1.3052.14.1.5.3.1
+
+ pdOutputFuse OBJECT IDENTIFIER ::= { pdOutput 4 }
+ --1.3.6.1.4.1.3052.14.1.5.3.4
+
+ pdNextGen OBJECT IDENTIFIER ::= { powerDistributionStatus 4 }
+ --1.3.6.1.4.1.3052.14.1.5.4
+
+ pdSystem OBJECT IDENTIFIER ::= { powerDistributionStatus 5 }
+ --1.3.6.1.4.1.3052.14.1.5.5
+
+ fuelSensorStatus OBJECT IDENTIFIER ::= { status 6 }
+ --1.3.6.1.4.1.3052.14.1.6
+
+ wirelessModemStatus OBJECT IDENTIFIER ::= { status 7 }
+ --1.3.6.1.4.1.3052.14.1.7
+
+ acPowerMonitorStatus OBJECT IDENTIFIER ::= { status 8 }
+ --1.3.6.1.4.1.3052.14.1.8
+
+ aisgStatus OBJECT IDENTIFIER ::= { status 9 }
+ --1.3.6.1.4.1.3052.14.1.9
+
+
+ config OBJECT IDENTIFIER ::= { s571 2 }
+ --1.3.6.1.4.1.3052.14.2
+
+ eventSensorBasics OBJECT IDENTIFIER ::= { config 1 }
+ --1.3.6.1.4.1.3052.14.2.1
+
+ eventSensorPointConfig OBJECT IDENTIFIER ::= { config 2 }
+ --1.3.6.1.4.1.3052.14.2.2
+
+ serialPorts OBJECT IDENTIFIER ::= { config 3 }
+ --1.3.6.1.4.1.3052.14.2.3
+
+ network OBJECT IDENTIFIER ::= { config 4 }
+ --1.3.6.1.4.1.3052.14.2.4
+
+ interface OBJECT IDENTIFIER ::= { network 1 }
+ --1.3.6.1.4.1.3052.14.2.4
+
+ ethernet OBJECT IDENTIFIER ::= { interface 1 }
+ --1.3.6.1.4.1.3052.14.2.4.1
+
+ ethernet1 OBJECT IDENTIFIER ::= { ethernet 1 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1
+
+ eth1VLAN OBJECT IDENTIFIER ::= { ethernet1 5 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.5
+
+ eth1VLAN1 OBJECT IDENTIFIER ::= { eth1VLAN 1 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.5.1
+
+ eth1VLAN2 OBJECT IDENTIFIER ::= { eth1VLAN 2 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.5.2
+
+ eth1VLAN3 OBJECT IDENTIFIER ::= { eth1VLAN 3 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.5.3
+
+ eth1VLAN4 OBJECT IDENTIFIER ::= { eth1VLAN 4 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.5.4
+
+ eth1VLAN5 OBJECT IDENTIFIER ::= { eth1VLAN 5 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.5.5
+
+ eth1VLAN6 OBJECT IDENTIFIER ::= { eth1VLAN 6 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.5.6
+
+ eth1IPv6 OBJECT IDENTIFIER ::= { ethernet1 7 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.7
+
+ eth1IPv6Static OBJECT IDENTIFIER ::= { eth1IPv6 2 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.7.2
+
+ eth1IPv6Auto OBJECT IDENTIFIER ::= { eth1IPv6 3 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.7.3
+
+ ethernet2 OBJECT IDENTIFIER ::= { ethernet 2 }
+ --1.3.6.1.4.1.3052.14.2.4.1.2
+
+ eth2VLAN OBJECT IDENTIFIER ::= { ethernet2 5 }
+ --1.3.6.1.4.1.3052.14.2.4.1.2.5
+
+ eth2VLAN1 OBJECT IDENTIFIER ::= { eth2VLAN 1 }
+ --1.3.6.1.4.1.3052.14.2.4.1.2.5.1
+
+ eth2VLAN2 OBJECT IDENTIFIER ::= { eth2VLAN 2 }
+ --1.3.6.1.4.1.3052.14.2.4.1.2.5.2
+
+ eth2VLAN3 OBJECT IDENTIFIER ::= { eth2VLAN 3 }
+ --1.3.6.1.4.1.3052.14.2.4.1.2.5.3
+
+ eth2VLAN4 OBJECT IDENTIFIER ::= { eth2VLAN 4 }
+ --1.3.6.1.4.1.3052.14.2.4.1.2.5.4
+
+ eth2VLAN5 OBJECT IDENTIFIER ::= { eth2VLAN 5 }
+ --1.3.6.1.4.1.3052.14.2.4.1.2.5.5
+
+ eth2VLAN6 OBJECT IDENTIFIER ::= { eth2VLAN 6 }
+ --1.3.6.1.4.1.3052.14.2.4.1.2.5.6
+
+ eth2IPv6 OBJECT IDENTIFIER ::= { ethernet2 7 }
+ --1.3.6.1.4.1.3052.14.2.4.1.2.7
+
+ eth2IPv6Static OBJECT IDENTIFIER ::= { eth2IPv6 2 }
+ --1.3.6.1.4.1.3052.14.2.4.1.2.7.2
+
+ eth2IPv6Auto OBJECT IDENTIFIER ::= { eth2IPv6 3 }
+ --1.3.6.1.4.1.3052.14.2.4.1.2.7.3
+
+ snmp OBJECT IDENTIFIER ::= { network 8 }
+ --1.3.6.1.4.1.3052.14.2.4.8
+
+ snmpNotificationTx OBJECT IDENTIFIER ::= { snmp 7 }
+ --1.3.6.1.4.1.3052.14.2.4.8.7
+
+ snmpPoll OBJECT IDENTIFIER ::= { snmp 9 }
+ --1.3.6.1.4.1.3052.14.2.4.8.9
+
+ ftpPush OBJECT IDENTIFIER ::= { network 9 }
+ --1.3.6.1.4.1.3052.14.2.4.9
+
+ ppp OBJECT IDENTIFIER ::= { network 10 }
+ --1.3.6.1.4.1.3052.14.2.4.10
+
+ pppDial OBJECT IDENTIFIER ::= { ppp 1 }
+ --1.3.6.1.4.1.3052.14.2.4.10.1
+
+ pppHost OBJECT IDENTIFIER ::= { ppp 2 }
+ --1.3.6.1.4.1.3052.14.2.4.10.2
+
+ routing OBJECT IDENTIFIER ::= { network 11 }
+ --1.3.6.1.4.1.3052.14.2.4.11
+
+ netSecurity OBJECT IDENTIFIER ::= { network 12 }
+ --1.3.6.1.4.1.3052.14.2.4.12
+
+ ipRestriction OBJECT IDENTIFIER ::= { netSecurity 1 }
+ --1.3.6.1.4.1.3052.14.2.4.12.1
+
+ rts OBJECT IDENTIFIER ::= { network 13 }
+ --1.3.6.1.4.1.3052.14.2.4.13
+
+ rtsAlarms OBJECT IDENTIFIER ::= { rts 2 }
+ --1.3.6.1.4.1.3052.14.2.4.13.2
+
+ trap OBJECT IDENTIFIER ::= { network 14 }
+ --1.3.6.1.4.1.3052.14.2.4.14
+
+ trapInclude OBJECT IDENTIFIER ::= { trap 1}
+ --1.3.6.1.4.1.3052.14.2.4.14.1
+
+ routeTest OBJECT IDENTIFIER ::= { network 15 }
+ --1.3.6.1.4.1.3052.14.2.4.15
+
+ wireless OBJECT IDENTIFIER ::= { network 16 }
+ --1.3.6.1.4.1.3052.14.2.4.16
+
+ wirelessConnectivity OBJECT IDENTIFIER ::= { wireless 20 }
+ --1.3.6.1.4.1.3052.14.2.4.16.20
+
+ email OBJECT IDENTIFIER ::= { network 17 }
+ --1.3.6.1.4.1.3052.14.2.4.17
+
+ netAdvanced OBJECT IDENTIFIER ::= { network 18 }
+ --1.3.6.1.4.1.3052.14.2.4.18
+
+ web OBJECT IDENTIFIER ::= { network 19 }
+ --1.3.6.1.4.1.3052.14.2.4.19
+
+ ipv6 OBJECT IDENTIFIER ::= { network 21 }
+ --1.3.6.1.4.1.3052.14.2.4.21
+
+ cpe OBJECT IDENTIFIER ::= { network 22 }
+ --1.3.6.1.4.1.3052.14.2.4.22
+
+ modem OBJECT IDENTIFIER ::= { config 5 }
+ --1.3.6.1.4.1.3052.14.2.5
+
+ modemClid OBJECT IDENTIFIER ::= { modem 8 }
+ --1.3.6.1.4.1.3052.14.2.5.7
+
+ time OBJECT IDENTIFIER ::= { config 8 }
+ --1.3.6.1.4.1.3052.14.2.8
+
+ console OBJECT IDENTIFIER ::= { config 10 }
+ --1.3.6.1.4.1.3052.14.2.10
+
+ unitSecurity OBJECT IDENTIFIER ::= { config 11 }
+ --1.3.6.1.4.1.3052.14.2.11
+
+ secCore OBJECT IDENTIFIER ::= { unitSecurity 1 }
+ --1.3.6.1.4.1.3052.14.2.11.1
+
+ secFactory OBJECT IDENTIFIER ::= { unitSecurity 3 }
+ --1.3.6.1.4.1.3052.14.2.11.3
+
+ secSSH OBJECT IDENTIFIER ::= { unitSecurity 4 }
+ --1.3.6.1.4.1.3052.14.2.11.4
+
+ secVPN OBJECT IDENTIFIER ::= { unitSecurity 5 }
+ --1.3.6.1.4.1.3052.14.2.11.5
+
+ event OBJECT IDENTIFIER ::= { config 12 }
+ --1.3.6.1.4.1.3052.14.2.12
+
+ evCore OBJECT IDENTIFIER ::= { event 1 }
+ --1.3.6.1.4.1.3052.14.2.12.1
+
+ evLog OBJECT IDENTIFIER ::= { evCore 3 }
+ --1.3.6.1.4.1.3052.14.2.12.1.3
+
+ evMgmt OBJECT IDENTIFIER ::= { evCore 4 }
+ --1.3.6.1.4.1.3052.14.2.12.1.4
+
+ evData OBJECT IDENTIFIER ::= { event 2 }
+ --1.3.6.1.4.1.3052.14.2.12.1
+
+ evdCore OBJECT IDENTIFIER ::= { evData 1 }
+ --1.3.6.1.4.1.3052.14.2.12.2.1
+
+ evNoData1 OBJECT IDENTIFIER ::= { event 3 }
+ --1.3.6.1.4.1.3052.14.2.12.1
+
+ evNoData2 OBJECT IDENTIFIER ::= { event 4 }
+ --1.3.6.1.4.1.3052.14.2.12.1
+
+ evSched1 OBJECT IDENTIFIER ::= { event 5 }
+ --1.3.6.1.4.1.3052.14.2.12.1
+
+ evSched2 OBJECT IDENTIFIER ::= { event 6 }
+ --1.3.6.1.4.1.3052.14.2.12.1
+
+ evNoSensor OBJECT IDENTIFIER ::= { event 9 }
+ --1.3.6.1.4.1.3052.14.2.12.1
+
+ fuelSensor OBJECT IDENTIFIER ::= { event 11 }
+ --1.3.6.1.4.1.3052.14.2.12.11
+
+ acPowerMonitor OBJECT IDENTIFIER ::= { event 12 }
+ --1.3.6.1.4.1.3052.14.2.12.12
+
+ evReset OBJECT IDENTIFIER ::= { event 16 }
+ --1.3.6.1.4.1.3052.14.2.12.16
+
+ action OBJECT IDENTIFIER ::= { config 14 }
+ --1.3.6.1.4.1.3052.14.2.14
+
+ actionSched OBJECT IDENTIFIER ::= { action 3 }
+ --1.3.6.1.4.1.3052.14.2.14.3
+
+ actionAsentria OBJECT IDENTIFIER ::= { action 4 }
+ --1.3.6.1.4.1.3052.14.2.14.4
+
+ sys OBJECT IDENTIFIER ::= { config 16 }
+ --1.3.6.1.4.1.3052.14.2.16
+
+ sysTime OBJECT IDENTIFIER ::= { sys 1 }
+ --1.3.6.1.4.1.3052.14.2.16.1
+
+ sysTimeNet OBJECT IDENTIFIER ::= { sysTime 4 }
+ --1.3.6.1.4.1.3052.14.2.16.1.4
+
+ sysPT OBJECT IDENTIFIER ::= { sys 2 }
+ --1.3.6.1.4.1.3052.14.2.16.2
+
+ sysTimeStamp OBJECT IDENTIFIER ::= { sys 8 }
+ --1.3.6.1.4.1.3052.14.2.16.8
+
+ sysLog OBJECT IDENTIFIER ::= { sys 9 }
+ --1.3.6.1.4.1.3052.14.2.16.9
+
+ sysCRDB OBJECT IDENTIFIER ::= { sys 10 }
+ --1.3.6.1.4.1.3052.14.2.16.10
+
+ sysLoc OBJECT IDENTIFIER ::= { sys 14 }
+ --1.3.6.1.4.1.3052.14.2.16.14
+
+ sysAssetMgmt OBJECT IDENTIFIER ::= { sys 15 }
+ --1.3.6.1.4.1.3052.14.2.16.15
+
+ sysFileTransfer OBJECT IDENTIFIER ::= { sys 17 }
+ --1.3.6.1.4.1.3052.14.2.16.17
+
+ sysUpdate OBJECT IDENTIFIER ::= { sys 18 }
+ --1.3.6.1.4.1.3052.14.2.16.18
+
+ auditLog OBJECT IDENTIFIER ::= { config 17 }
+ --1.3.6.1.4.1.3052.14.2.17
+
+ scripting OBJECT IDENTIFIER ::= { config 18 }
+ --1.3.6.1.4.1.3052.14.2.18
+
+ productIds OBJECT IDENTIFIER ::= { s571 3 }
+ --1.3.6.1.4.1.3052.14.3
+
+--***************************************************************************************
+--OBJECT DEFINITIONS
+--***************************************************************************************
+
+--***************************************************************************************
+--EventSensor Status Section 1.1
+--***************************************************************************************
+
+esPointTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ESPoint
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "
+ This table organizes 4 basic attributes of points. A point
+ is a particular sensor on an EventSensor (e.g., temperature,
+ humidity, contact closure 2, output 5, etc.). The 4 point
+ attributes are its name, whether it's in its event state,
+ the point's value as a number and its value as a string.
+
+ Points are referenced by a point index. The point index
+ is a string of 3 numbers separated by periods.
+ It contains all the information necessary for getting a piece
+ of data off an event sensor; namely, which EventSensor,
+ point class, and which-sensor-of-that-class (a.k.a. point).
+ "
+ ::= { eventSensorStatus 1 }
+ --1.3.6.1.4.1.3052.14.1.1.1
+
+esPointEntry OBJECT-TYPE
+ SYNTAX ESPoint
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for EventSensor point table"
+ INDEX { esIndexES, esIndexPC, esIndexPoint }
+ ::= { esPointTable 1 }
+ --1.3.6.1.4.1.3052.14.1.1.1.1
+
+esIndexES OBJECT-TYPE
+ SYNTAX Integer32 (1..200)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The part of the point index that refers to an
+ EventSensor.
+
+ The point index is a string of 3 numbers separated
+ by periods. It contains all the information
+ necessary for getting a piece of data off an event
+ sensor; namely, which EventSensor, point class,
+ and which-sensor-of-that-class (a.k.a. point).
+
+ This object's allowable values are 1 through 16,
+ and 200. 200 always refers to the EventSensor
+ inside the unit. 1 through 16 refer to additional
+ attached EventSensors.
+
+ The number corresponding to an EventSensor is
+ determined by the user at the initial configuration
+ time. If there is an internal sensor in the unit,
+ it will always be the first item in the Sensor
+ Events setup menu.
+
+ For example, if a new EventSensor is configured as
+ the 2nd entry AFTER the internal EventSensor (if
+ one exists) in the Sensor Events Setup Menu, then
+ that EventSensor will be known from then on as
+ EventSensor 2. All point indeces with esIndexES=2
+ will now refer to that particular EventSensor.
+ "
+ ::= { esPointEntry 1 }
+ --1.3.6.1.4.1.3052.14.1.1.1.1.1
+
+esIndexPC OBJECT-TYPE
+ SYNTAX Integer32 (1..6)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The part of the point index that refers to point class.
+
+ The point index is a string of 3 numbers separated by periods.
+ It contains all the information necessary for getting a piece
+ of data off an event sensor; namely, which EventSensor,
+ point class, and which-sensor-of-that-class (a.k.a. point).
+
+ The values for this object are:
+ 1=temperature sensor
+ 2=contact closure
+ 3=humidity sensor
+ 4=noise sensor
+ 5=analog input
+ 6=output (relay output or power output)
+ "
+ ::= { esPointEntry 2 }
+ --1.3.6.1.4.1.3052.14.1.1.1.1.2
+
+esIndexPoint OBJECT-TYPE
+ SYNTAX Integer32 (1..64)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The part of the point index that delineates which
+ sensor on the EventSensor.
+
+ So this combined with esIndexPC (Point Class or type)
+ and esIndexES (which EventSensor) uniquely defines each
+ point (sensor or output) attached to a unit. For
+ example, if esIndexES is 3, esIndexPC is 1 and
+ esIndexPoint is 4 then this is the Fourth Temperature
+ Sensor on EventSensor number 3."
+ ::= { esPointEntry 3 }
+ --1.3.6.1.4.1.3052.14.1.1.1.1.3
+
+esPointName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The name of the point on an EventSensor. For example,
+ 'AC temp' (in the case of the temperature sensor on an
+ EventSensor).
+
+ There can be multiple points of the same point class on an
+ EventSensor (e.g., 8 contact closures) and multiple sensor
+ classes on an EventSensor (e.g., temperature, contact closure,
+ humidity).
+
+ If the point referenced by a given point index is solitary
+ (e.g., temperature sensor, because there can be only one on
+ an EventSensor), then this object reads as '<EventSensor
+ name>'. Setting this object for solitary point indices sets
+ the EventSensor name only.
+
+ On the other hand, if a given point is among other points of
+ the same point class on an EventSensor, then this object reads
+ as '<Sensor name>'. Setting this object for these NON-
+ solitary point indices sets the sensor name only - not the
+ EventSensor name."
+ ::= { esPointEntry 4 }
+ --1.3.6.1.4.1.3052.14.1.1.1.1.4
+
+esPointInEventState OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A number referring to the event state of a point
+ on an EventSensor. This number can have different
+ meanings depending on the point class.
+
+ If the point class is temperature, humidity, or
+ analog input, then the values of this object are:
+ 1=very low
+ 2=low
+ 3=normal
+ 4=high
+ 5=very high
+
+ For contact closures the values of this object are:
+ 1=point in event state
+ 2=point in normal state
+
+ For outputs the values of this object is the numeric
+ code for the logical state of the output: 1 or 2. The
+ logical state of the output is either active/inactive for
+ relay outputs or on/off for power outputs. The logical
+ state of the output has different nomenclature depending
+ on the type of the output (relay output or power output):
+
+ 1=active (for relay output) or on (for power output)
+ 2=inactive (for relay output) or off (for power output)
+
+ This is not necessarily representative of physical state
+ of the output. Physical state is energized/de-energized,
+ for both relay and power outputs. For relay outputs,
+ the active logical state corresponds to either the energized
+ physical state or the de-energized physical state depending
+ on how the relay output is configured. For power outputs,
+ the on logical state always corresponds to the energized
+ physical state.
+
+ For any point class and any point, if the event
+ state is undefined, then the value of this object
+ is 0.
+
+ For any point class except output, this object is read-only.
+ For outputs, setting this object to 1 puts the output into
+ its active logical state.
+
+ Setting this object to 2 puts the output into its inactive
+ logical state.
+
+ Setting this object to any value greater than 2 puts the
+ output into its active logical state for that many seconds
+ (up to 3600), after which time it puts the output into its
+ inactive logical state.
+ "
+ ::= { esPointEntry 5 }
+ --1.3.6.1.4.1.3052.14.1.1.1.1.5
+
+esPointValueInt OBJECT-TYPE
+ SYNTAX Integer32 (-2147483648..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A read-only number referring to the value of a
+ point on an EventSensor.
+
+ If the point class is temperature, then this object
+ is the temperature in its configured scale (default
+ is Fahrenheit).
+
+ If the point class is contact closure, then
+ this object is either 0 (open) or 1 (closed).
+
+ If the point class is humidity, then this object
+ is the percent relative humidity.
+
+ If the point class is analog input, then this
+ object is the signed input value in tenths of the
+ configured units.
+
+ If the point class is an output, then this object is
+ the numeric code for the physical state of the output.
+ 0=de-energized
+ 1=energized
+
+ This object cannot be used to control the output, i.e,
+ change its logical or physical state (instead use
+ the esPointInEventState object).
+ "
+ ::= { esPointEntry 6 }
+ --1.3.6.1.4.1.3052.14.1.1.1.1.6
+
+esPointValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A string referring to the value of a point on an
+ EventSensor.
+
+ For contact closures this object is either 'Open'
+ or 'Closed'.
+
+ For outputs this object is a concatenation of the
+ logical state and physical state, separated by '/'.
+
+ For a relay output this object can be one of the
+ following 4 possible values:
+
+ Active/Energized
+ Inactive/Energized
+ Active/De-energized
+ Inactve/De-energized
+
+ For a power output this object can be one of the
+ following 2 possible values:
+
+ On/Energized
+ Off/De-energized
+
+ For temperature and humidity point classes, this
+ object is the string representation of the
+ esPointValueInt object. For temperature, 'C' or
+ 'F' is including in the string to indicate scale.
+
+ For analog inputs, this object is the string
+ representation of the plus/minus input in the
+ configured units appended with the unit name.
+ "
+ ::= { esPointEntry 7 }
+ --1.3.6.1.4.1.3052.14.1.1.1.1.7
+
+esPointTimeLastChange OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The time of the last time an event was
+ triggerred for a point on an EventSensor in
+ MM/DD/YY HH:MM:SS format.
+
+ For contact closures, the possible events are
+ Active and Inactive. For temperature, humidity,
+ and analog inputs, the possible events are Normal,
+ High, Very High, Low, and Very Low.
+
+ For outputs, this object is a null string."
+ ::= { esPointEntry 8 }
+ --1.3.6.1.4.1.3052.14.1.1.1.1.8
+
+esPointTimetickLastChange OBJECT-TYPE
+ SYNTAX TimeTicks
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The time of the last time an event was
+ triggerred for a point on an EventSensor in
+ 100ths of seconds since reset.
+
+ For contact closures, the possible events are
+ Active and Inactive. For temperature, humidity,
+ and analog inputs, the possible events are Normal,
+ High, Very High, Low, and Very Low.
+
+ For outputs, this object is 0."
+ ::= { esPointEntry 9 }
+ --1.3.6.1.4.1.3052.14.1.1.1.1.9
+
+--***************************************************************************************
+--Data Event Status Section 1.2
+--***************************************************************************************
+
+deStatusTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF DEStatus
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Data Event Status Table"
+ ::= { dataEventStatus 1 }
+ --1.3.6.1.4.1.3052.14.1.2.1
+
+deStatusEntry OBJECT-TYPE
+ SYNTAX DEStatus
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "EventSensor status entry"
+ INDEX { deStatusIndex }
+ ::= { deStatusTable 1 }
+ --1.3.6.1.4.1.3052.14.1.2.1.1
+
+deStatusIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..100)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for Data Events"
+ ::= { deStatusEntry 1 }
+ --1.3.6.1.4.1.3052.14.1.2.1.1.1
+
+deStatusName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Data Event name"
+ ::= { deStatusEntry 2 }
+ --1.3.6.1.4.1.3052.14.1.2.1.1.2
+
+deStatusCounter OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of times a data record has matched this
+ event's equation.
+ Range: 1-999999999"
+ ::= { deStatusEntry 3 }
+ --1.3.6.1.4.1.3052.14.1.2.1.1.3
+
+deStatusThreshold OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of times the equation is matched before
+ an event is triggered.
+ Range: 1-999999999"
+ ::= { deStatusEntry 4 }
+ --1.3.6.1.4.1.3052.14.1.2.1.1.4
+
+modemStatus OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "status of modem (idle, dialing, connected, etc.)"
+ ::= { status 3 }
+ --1.3.6.1.4.1.3052.14.1.3
+
+modemCLIDLogTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ModemCLIDLogConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of numbers of recent dialing parties"
+ ::= { status 4 }
+ --1.3.6.1.4.1.3052.14.1.4
+
+modemCLIDLogEntry OBJECT-TYPE
+ SYNTAX ModemCLIDLogConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of CLID log entries"
+ INDEX { modemCLIDLogIndex }
+ ::= { modemCLIDLogTable 1 }
+ --1.3.6.1.4.1.3052.14.1.4.1
+
+modemCLIDLogIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..8)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of CLID log entries"
+ ::= { modemCLIDLogEntry 1 }
+ --1.3.6.1.4.1.3052.14.1.4.1.1
+
+modemCLIDLogNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "recently logged number of dialing party"
+ ::= { modemCLIDLogEntry 2 }
+ --1.3.6.1.4.1.3052.14.1.4.1.2
+
+--***************************************************************************************
+--Power Distribution Status Section 1.5
+--***************************************************************************************
+
+pdConfig OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Power Distribution output configuration"
+ ::= { powerDistributionStatus 1 }
+ --1.3.6.1.4.1.3052.14.1.5.1
+
+pdMainCurrentInEventState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Power Distribution main current event state"
+ ::= { pdMainCurrent 2 }
+ --1.3.6.1.4.1.3052.14.1.5.2.1.2
+
+pdMainCurrentValue OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Power Distribution main current value in mA"
+ ::= { pdMainCurrent 3 }
+ --1.3.6.1.4.1.3052.14.1.5.2.1.3
+
+pdMainCurrentValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Power Distribution main current value formatted as a string"
+ ::= { pdMainCurrent 4 }
+ --1.3.6.1.4.1.3052.14.1.5.2.1.4
+
+pdMainCurrentDeadband OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Power Distribution main current sensor deadband in mA"
+ ::= { pdMainCurrent 10 }
+ --1.3.6.1.4.1.3052.14.1.5.2.1.10
+
+pdMainCurrentVHighCurrent OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Power Distribution main current sensor very high threshold in mA"
+ ::= { pdMainCurrent 11 }
+ --1.3.6.1.4.1.3052.14.1.5.2.1.11
+
+pdMainCurrentHighCurrent OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Power Distribution main current sensor high threshold in mA"
+ ::= { pdMainCurrent 12 }
+ --1.3.6.1.4.1.3052.14.1.5.2.1.12
+
+pdMainCurrentLowCurrent OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Power Distribution main current sensor low threshold in mA"
+ ::= { pdMainCurrent 13 }
+ --1.3.6.1.4.1.3052.14.1.5.2.1.13
+
+pdMainCurrentVLowCurrent OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Power Distribution main current sensor very low threshold in mA"
+ ::= { pdMainCurrent 14 }
+ --1.3.6.1.4.1.3052.14.1.5.2.1.14
+
+pdMainVoltageInEventState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Power Distribution main voltage event state"
+ ::= { pdMainVoltage 2 }
+ --1.3.6.1.4.1.3052.14.1.5.2.2.2
+
+pdMainVoltageValue OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Power Distribution main voltage value in mV"
+ ::= { pdMainVoltage 3 }
+ --1.3.6.1.4.1.3052.14.1.5.2.2.3
+
+pdMainVoltageValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Power Distribution main voltage value formatted as a string"
+ ::= { pdMainVoltage 4 }
+ --1.3.6.1.4.1.3052.14.1.5.2.2.4
+
+pdMainVoltageDeadband OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Power Distribution main voltage sensor deadband in mV"
+ ::= { pdMainVoltage 10 }
+ --1.3.6.1.4.1.3052.14.1.5.2.2.10
+
+pdMainVoltageVHighVoltage OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Power Distribution main voltage sensor very high threshold in mV"
+ ::= { pdMainVoltage 11 }
+ --1.3.6.1.4.1.3052.14.1.5.2.2.11
+
+pdMainVoltageHighVoltage OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Power Distribution main voltage sensor high threshold in mV"
+ ::= { pdMainVoltage 12 }
+ --1.3.6.1.4.1.3052.14.1.5.2.2.12
+
+pdMainVoltageLowVoltage OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Power Distribution main voltage sensor low threshold in mV"
+ ::= { pdMainVoltage 13 }
+ --1.3.6.1.4.1.3052.14.1.5.2.2.13
+
+pdMainVoltageVLowVoltage OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Power Distribution main voltage sensor very low threshold in mV"
+ ::= { pdMainVoltage 14 }
+ --1.3.6.1.4.1.3052.14.1.5.2.2.14
+
+pdMainPowerValue OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Power Distribution main power value in Watts"
+ ::= { pdMainPower 3 }
+ --1.3.6.1.4.1.3052.14.1.5.2.3.3
+
+pdMainPowerValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Power Distribution main power value formatted as a string"
+ ::= { pdMainPower 4 }
+ --1.3.6.1.4.1.3052.14.1.5.2.3.4
+
+pdOutputCurrentTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PowerDistribOutputCurrent
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of power output current values"
+ ::= { pdOutput 1 }
+ --1.3.6.1.4.1.3052.14.1.5.3.1
+
+pdOutputCurrentEntry OBJECT-TYPE
+ SYNTAX PowerDistribOutputCurrent
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of output current values"
+ INDEX { pdOutputCurrentIndex }
+ ::= { pdOutputCurrentTable 1 }
+ --1.3.6.1.4.1.3052.14.1.5.3.1.1
+
+pdOutputCurrentIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..13)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of power output current values"
+ ::= { pdOutputCurrentEntry 1 }
+ --1.3.6.1.4.1.3052.14.1.5.3.1.1.1
+
+pdOutputCurrentInEventState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The event state of this power distribution output
+ current (Very Low, Low, Normal, High, Very High)"
+ ::= { pdOutputCurrentEntry 2 }
+ --1.3.6.1.4.1.3052.14.1.5.3.1.1.2
+
+pdOutputCurrentValue OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Output current value in mA"
+ ::= { pdOutputCurrentEntry 3 }
+ --1.3.6.1.4.1.3052.14.1.5.3.1.1.3
+
+pdOutputCurrentValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Output current value formatted as a fixed-point string
+ in Amps."
+ ::= { pdOutputCurrentEntry 4 }
+ --1.3.6.1.4.1.3052.14.1.5.3.1.1.4
+
+pdOutputCurrentDeadband OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Deadband for this power output current sensor"
+ ::= { pdOutputCurrentEntry 10 }
+ --1.3.6.1.4.1.3052.14.1.5.3.1.1.10
+
+pdOutputCurrentVHighCurrent OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high threshold for this power output current sensor"
+ ::= { pdOutputCurrentEntry 11 }
+ --1.3.6.1.4.1.3052.14.1.5.3.1.1.11
+
+pdOutputCurrentHighCurrent OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High threshold for this power output current sensor"
+ ::= { pdOutputCurrentEntry 12 }
+ --1.3.6.1.4.1.3052.14.1.5.3.1.1.12
+
+pdOutputCurrentVLowCurrent OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low threshold for this power output current sensor"
+ ::= { pdOutputCurrentEntry 13 }
+ --1.3.6.1.4.1.3052.14.1.5.3.1.1.13
+
+pdOutputCurrentLowCurrent OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low threshold for this power output current sensor"
+ ::= { pdOutputCurrentEntry 14 }
+ --1.3.6.1.4.1.3052.14.1.5.3.1.1.14
+
+pdOutputFuseTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PowerDistribOutputFuse
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of output fuse values"
+ ::= { pdOutput 4 }
+ --1.3.6.1.4.1.3052.14.1.5.3.4
+
+pdOutputFuseEntry OBJECT-TYPE
+ SYNTAX PowerDistribOutputFuse
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of output fuse values"
+ INDEX { pdOutputFuseIndex }
+ ::= { pdOutputFuseTable 1 }
+ --1.3.6.1.4.1.3052.14.1.5.3.4.1
+
+pdOutputFuseIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..13)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of output fuse values"
+ ::= { pdOutputFuseEntry 1 }
+ --1.3.6.1.4.1.3052.14.1.5.3.4.1.1
+
+pdOutputFuseInEventState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A number referring to the event state of a power
+ distribution output fuse.
+
+ 14=fuse blown
+ 15=fuse ok"
+ ::= { pdOutputFuseEntry 2 }
+ --1.3.6.1.4.1.3052.14.1.5.3.4.1.2
+
+pdOutputFuseValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Output fuse value formatted as a string. E.g.,
+ 'BLOWN' or 'OK'"
+ ::= { pdOutputFuseEntry 4 }
+ --1.3.6.1.4.1.3052.14.1.5.3.4.1.4
+
+pdnTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PowerDistribNextGen
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of power distribution objects arranged according
+ to next-generation methodology (i.e., using multiple PowerBoss
+ power distributors in addition to the on-board power
+ distributor)."
+ ::= { pdNextGen 1 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1
+
+pdnEntry OBJECT-TYPE
+ SYNTAX PowerDistribNextGen
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of power distribution objects arranged according
+ to next-generation methodology (i.e., using multiple PowerBoss
+ power distributors in addition to the on-board power
+ distributor)."
+ INDEX { pdnIndexPD, pdnIndexOutput }
+ ::= { pdnTable 1 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1.1
+
+pdnIndexPD OBJECT-TYPE
+ SYNTAX Integer32 (1..200)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of power distribution objects, specifically the
+ index that refers to which power distributor. A value of 200 means
+ the internal power distributor. A value from 1 to 16 refers to a
+ PowerBoss external power distributor, and is the same value as esIndexES,
+ which refers to the PowerBoss as an EventSensor in the eventSensorStatus
+ object table. In other words, pdnIndexPD is the same as esIndexES:
+ esIndexES is used to refer to the PowerBoss as an eventsensor (i.e., control
+ outputs), while pdnIndexPD is used to refer to the PowerBoss when used for
+ power distribution monitoring (i.e., to alarm on output
+ current/voltage/fuse status)."
+ ::= { pdnEntry 1 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1.1.1
+
+pdnIndexOutput OBJECT-TYPE
+ SYNTAX Integer32 (1..12)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of power distribution objects, specifically the
+ index that refers to which output on the power distributor specified
+ by pdnIndexPD. For objects where the output is irrelevant, this index
+ should be 1."
+ ::= { pdnEntry 2 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1.1.2
+
+pdnConfig OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of outputs on the power distributor specified by pdnIndexPD.
+ pdnIndexOutput should be 1 for this object."
+ ::= { pdnEntry 3 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1.1.3
+
+pdnMainCurrentInEventState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The event state of the current (i.e. Amps) event of the power distributor
+ specified by pdnIndexPD. pdnIndexOutput should be 1 for this object.
+ Possible values for this object are: 'Very Low', 'Low', 'Normal', 'High',
+ 'Very High'."
+ ::= { pdnEntry 4 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1.1.4
+
+pdnMainCurrentValue OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current drawn, in mA, for the power distributor specified by pdnIndexPD.
+ If pdnIndexPD is 200 then this is the internal power distributor and refers to
+ the current drawn by the S571 (which is comprised of the internal power
+ distributor and ancillary internal equipment) and all equipment powered by the
+ S571's internal power outputs. If pdnIndexPD is 1-16 then this is an external
+ power distributor (PowerBoss) and refers to the current drawn by that PowerBoss and all
+ equipment powered by that PowerBoss. pdnIndexOutput should be 1 for this object."
+ ::= { pdnEntry 5 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1.1.5
+
+pdnMainCurrentValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Essentially pdnMainCurrentValue formatted as a string in units of Amps, with
+ 3 decimal places. pdnIndexOutput should be 1 for this object."
+ ::= { pdnEntry 6 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1.1.6
+
+pdnMainCurrentDeadband OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The deadband, in mA, for the main current sensor for the power distributor
+ specified by pdIndexPD. pdnIndexOutput should be 1 for this object."
+ ::= { pdnEntry 7 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1.1.7
+
+pdnMainCurrentVHighCurrent OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current, in mA, for the main current sensor's Very High event threshold,
+ for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1
+ for this object."
+ ::= { pdnEntry 8 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1.1.8
+
+pdnMainCurrentHighCurrent OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current, in mA, for the main current sensor's High event threshold,
+ for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1
+ for this object."
+ ::= { pdnEntry 9 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1.1.9
+
+pdnMainCurrentLowCurrent OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current, in mA, for the main current sensor's Low event threshold,
+ for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1
+ for this object."
+ ::= { pdnEntry 10 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1.1.10
+
+pdnMainCurrentVLowCurrent OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current, in mA, for the main current sensor's Very Low event threshold,
+ for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1
+ for this object."
+ ::= { pdnEntry 11 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1.1.11
+
+pdnMainVoltageInEventState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The event state of the voltage event of the power distributor
+ specified by pdnIndexPD. pdnIndexOutput should be 1 for this object.
+ Possible values for this object are: 'Very Low', 'Low', 'Normal', 'High',
+ 'Very High'."
+ ::= { pdnEntry 12 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1.1.12
+
+pdnMainVoltageValue OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The voltage, in mV, at the power distributor specified by pdnIndexPD.
+ If pdnIndexPD is 200 then this is the internal power distributor and refers to
+ the voltage at the S571 (which is comprised of the internal power
+ distributor and ancillary internal equipment) and all equipment powered by the
+ S571's internal power outputs. If pdnIndexPD is 1-16 then this is an external
+ power distributor (PowerBoss) and refers to the voltage at that PowerBoss and all
+ equipment powered by that PowerBoss. pdnIndexOutput should be 1 for this object."
+ ::= { pdnEntry 13 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1.1.13
+
+pdnMainVoltageValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Essentially pdnMainVoltageValue formatted as a string in units of Volts, with
+ 3 decimal places. pdnIndexOutput should be 1 for this object."
+ ::= { pdnEntry 14 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1.1.14
+
+pdnMainVoltageDeadband OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The deadband, in mV, for the main voltage sensor for the power distributor
+ specified by pdIndexPD. pdnIndexOutput should be 1 for this object."
+ ::= { pdnEntry 15 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1.1.15
+
+pdnMainVoltageVHighVoltage OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The voltage, in mA, for the main voltage sensor's Very High event threshold,
+ for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1
+ for this object."
+ ::= { pdnEntry 16 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1.1.16
+
+pdnMainVoltageHighVoltage OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The voltage, in mV, for the main voltage sensor's High event threshold,
+ for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1
+ for this object."
+ ::= { pdnEntry 17 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1.1.17
+
+pdnMainVoltageLowVoltage OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The voltage, in mV, for the main voltage sensor's Low event threshold,
+ for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1
+ for this object."
+ ::= { pdnEntry 18 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1.1.18
+
+pdnMainVoltageVLowVoltage OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The voltage, in mV, for the main voltage sensor's Very Low event threshold,
+ for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1
+ for this object."
+ ::= { pdnEntry 19 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1.1.19
+
+pdnMainPowerValue OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The power, in Watts, for the power distributor specified by pdIndexPD.
+ pdnIndexOutput should be 1 for this object."
+ ::= { pdnEntry 20 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1.1.20
+
+pdnMainPowerValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The power, in Watts, for the power distributor specified by pdIndexPD,
+ formatted as a string with the unit name 'Watts'. pdnIndexOutput should be 1
+ for this object."
+ ::= { pdnEntry 21 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1.1.21
+
+pdnOutputCurrentInEventState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The event state of the current (i.e. Amps) event of the power distributor
+ output specified by pdnIndexPD and pdnIndexOutput. E.g., for pdnIndexPD=200
+ and pdnIndexOutput=2, this refers to power output #2 of the internal power
+ distributor. Possible values for this object are: 'Very Low', 'Low', 'Normal',
+ 'High', 'Very High'."
+ ::= { pdnEntry 22 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1.1.22
+
+pdnOutputCurrentValue OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current drawn, in mA, for the power distributor output specified by
+ pdnIndexPD and pdIndexOutput. If pdnIndexPD is 200 then this is the internal
+ power distributor and refers to the current drawn by a specific power output
+ on the S571. If pdIndexPD is 3 then this is an external power distributor (PowerBoss)
+ identified as 'power distributor 3' and refers to the current drawn by a
+ specific power output on that PowerBoss. The specific power output is specified by
+ pdIndexOutput."
+ ::= { pdnEntry 23 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1.1.23
+
+pdnOutputCurrentValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Essentially pdnOutputCurrentValue formatted as a string in units of Amps, with
+ 3 decimal places."
+ ::= { pdnEntry 24 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1.1.24
+
+pdnOutputCurrentDeadband OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The deadband, in mA, for the main current sensor for the power distributor
+ specified by pdIndexPD. The power output is specified by pdnIndexOutput."
+ ::= { pdnEntry 25 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1.1.25
+
+pdnOutputCurrentVHighCurrent OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current, in mA, for a specific power output's current sensor Very High
+ event threshold, for the power distributor specified by pdIndexPD. The power
+ output is specified by pdnIndexOutput."
+ ::= { pdnEntry 26 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1.1.26
+
+pdnOutputCurrentHighCurrent OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current, in mA, for a specific power output's current sensor High event
+ threshold, for the power distributor specified by pdIndexPD. The power output
+ is specified by pdnIndexOutput for this object."
+ ::= { pdnEntry 27 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1.1.27
+
+pdnOutputCurrentLowCurrent OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current, in mA, for a specific power output's current sensor Low event
+ threshold, for the power distributor specified by pdIndexPD. The power output
+ is specified by pdnIndexOutput for this object."
+ ::= { pdnEntry 28 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1.1.28
+
+pdnOutputCurrentVLowCurrent OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current, in mA, for a specific power output's current sensor Very Low
+ event threshold, for the power distributor specified by pdIndexPD. The power
+ output is specified by pdnIndexOutput for this object."
+ ::= { pdnEntry 29 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1.1.29
+
+pdnOutputFuseInEventState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The event state of the fuse event of the power distributor output specified
+ by pdnIndexPD and pdnIndexOutput. E.g., for pdnIndexPD=14 and pdnIndexOutput=2,
+ this refers to power output #2 of the PowerBoss external power distributor,
+ identified as 'power distributor 14'. Possible values for this object are:
+ 'Very Low', 'Low', 'Normal', 'High', 'Very High'. This object exists only for
+ power distributors with fuse monitoring support."
+ ::= { pdnEntry 30 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1.1.30
+
+pdnOutputFuseValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The state of the fuse of the power distributor output specified
+ by pdnIndexPD and pdnIndexOutput. Possible values for this object are:
+ 'BLOWN' and 'OK'. This object exists only for power distributors with
+ fuse monitoring support."
+ ::= { pdnEntry 31 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1.1.31
+
+pdnMainCombinedStatus OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ format: voltageColorCode`voltageEventState`voltageValue`mainCurrentColorCode`mainCurrentEventState`mainCurrentValue`deviceCurrentValue`mainPowerValue"
+ ::= { pdnEntry 32 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1.1.32
+
+pdnOutputCombinedStatusBlock1 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ format: numInBlock~outputCurrentColorCode1`outputCurrentEventState1`outputCurrentValue1`fuseColorCode1`fuseValue1~..."
+ ::= { pdnEntry 33 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1.1.33
+
+pdnOutputCombinedStatusBlock2 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ format: numInBlock~outputCurrentColorCode1`outputCurrentEventState1`outputCurrentValue1`fuseColorCode1`fuseValue1~..."
+ ::= { pdnEntry 34 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1.1.34
+
+pdnDeviceCurrentValue OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Current drawn by device in mA. For the internal power distributor device,
+ this is the current drawn by the SiteBoss 571. For an external power
+ distributor device (PowerBoss), this is the current drawn by the
+ PowerBoss. This object exists only for power distributors with device
+ current monitoring support."
+ ::= { pdnEntry 35 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1.1.35
+
+pdnDeviceCurrentValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Current drawn by device as a string with units (Amps). For the internal
+ power distributor device, this is the current drawn by the SiteBoss 571.
+ For an external power distributor device (PowerBoss), this is the
+ current drawn by the PowerBoss. This object exists only for power
+ distributors with device current monitoring support."
+ ::= { pdnEntry 36 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1.1.36
+
+pdSystemCurrent OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total current drawn by all power distributors in system; that is, the
+ sum of all pdnMainCurrentValue objects for all connected power
+ distributors: internal and external."
+ ::= { pdSystem 1 }
+ --1.3.6.1.4.1.3052.14.1.5.5.1
+
+pdSystemPower OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total power used by all power distributors in system; that is, the
+ sum of all pdnMainPowerValue objects for all connected power
+ distributors: internal and external."
+ ::= { pdSystem 2 }
+ --1.3.6.1.4.1.3052.14.1.5.5.2
+
+
+--***************************************************************************************
+--Fuel Sensor 1.5
+--***************************************************************************************
+
+fsStatusTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF FSStatus
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor status table"
+ ::= { fuelSensorStatus 1 }
+ --1.3.6.1.4.1.3052.14.1.6.1
+
+fsStatusEntry OBJECT-TYPE
+ SYNTAX FSStatus
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor status table entry"
+ INDEX { fsStatusIndex }
+ ::= { fsStatusTable 1 }
+ --1.3.6.1.4.1.3052.14.1.6.1.1
+
+fsStatusIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..3)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for fuel sensors"
+ ::= { fsStatusEntry 1 }
+ --1.3.6.1.4.1.3052.14.1.6.1.1.1
+
+fsStatusName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor name"
+ ::= { fsStatusEntry 2 }
+ --1.3.6.1.4.1.3052.14.1.6.1.1.2
+
+fsStatusDeviceState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor device state"
+ ::= { fsStatusEntry 3 }
+ --1.3.6.1.4.1.3052.14.1.6.1.1.3
+
+fsStatusVolumeValueString OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Fuel volume. Range is -2,147,483,648 to 2,147,483,647. This value reads
+ -999 when the fuel sensor is disconnected"
+ ::= { fsStatusEntry 4 }
+ --1.3.6.1.4.1.3052.14.1.6.1.1.4
+
+fsStatusVolumePercentLevel OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Height of the fluid in the tank expressed as a percentage of the tank
+ height, in hundredths of a percent."
+ ::= { fsStatusEntry 7 }
+ --1.3.6.1.4.1.3052.14.1.6.1.1.7
+
+fsStatusVolumeInEventState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Current event status of the fuel sensor."
+ ::= { fsStatusEntry 8 }
+ --1.3.6.1.4.1.3052.14.1.6.1.1.8
+
+fsStatusCombined OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ deviceState`deviceStateColorCode`percentRounded`valueAsFloat`volumeEventState`volumeEventStateColorCode`capacity`units`name"
+ ::= { fsStatusEntry 9 }
+ --1.3.6.1.4.1.3052.14.1.6.1.1.9
+
+
+--***************************************************************************************
+--Wireless Modem Status Section 1.7
+--***************************************************************************************
+
+wmsStatus OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem status"
+ ::= { wirelessModemStatus 1 }
+ --1.3.6.1.4.1.3052.14.1.7.1
+
+wmsSignal OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem Signal strength"
+ ::= { wirelessModemStatus 2 }
+ --1.3.6.1.4.1.3052.14.1.7.2
+
+wmsRSSI OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem Signal strength (RSSI)"
+ ::= { wirelessModemStatus 3 }
+ --1.3.6.1.4.1.3052.14.1.7.3
+
+wmsBER OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem Bit Error Rate"
+ ::= { wirelessModemStatus 4 }
+ --1.3.6.1.4.1.3052.14.1.7.4
+
+wmsUpdated OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem info last update time"
+ ::= { wirelessModemStatus 5 }
+ --1.3.6.1.4.1.3052.14.1.7.5
+
+wmsRegistration OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem registration status"
+ ::= { wirelessModemStatus 6 }
+ --1.3.6.1.4.1.3052.14.1.7.6
+
+wmsLAC OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem Location Area Code"
+ ::= { wirelessModemStatus 7 }
+ --1.3.6.1.4.1.3052.14.1.7.7
+
+wmsCellID OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem Cell ID"
+ ::= { wirelessModemStatus 8 }
+ --1.3.6.1.4.1.3052.14.1.7.8
+
+wmsIMSI OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem Internation Mobile Subscriber Identity number"
+ ::= { wirelessModemStatus 9 }
+ --1.3.6.1.4.1.3052.14.1.7.9
+
+wmsPhnum OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem phone number"
+ ::= { wirelessModemStatus 10 }
+ --1.3.6.1.4.1.3052.14.1.7.10
+
+wmsLocalIP OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Local IP address of modem on wireless network"
+ ::= { wirelessModemStatus 11 }
+ --1.3.6.1.4.1.3052.14.1.7.11
+
+wmsMgfID OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem manufacturer ID"
+ ::= { wirelessModemStatus 12 }
+ --1.3.6.1.4.1.3052.14.1.7.12
+
+wmsModelID OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem model ID"
+ ::= { wirelessModemStatus 13 }
+ --1.3.6.1.4.1.3052.14.1.7.13
+
+wmsIMEI OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem International Mobile Equipment Identity number"
+ ::= { wirelessModemStatus 14 }
+ --1.3.6.1.4.1.3052.14.1.7.14
+
+wmsRevID OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem revision ID"
+ ::= { wirelessModemStatus 15 }
+ --1.3.6.1.4.1.3052.14.1.7.15
+
+wmsNetName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem network name"
+ ::= { wirelessModemStatus 16 }
+ --1.3.6.1.4.1.3052.14.1.7.16
+
+wmsGPRSStatus OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem (E)GPRS status"
+ ::= { wirelessModemStatus 17 }
+ --1.3.6.1.4.1.3052.14.1.7.17
+
+wmsBand OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem band"
+ ::= { wirelessModemStatus 18 }
+ --1.3.6.1.4.1.3052.14.1.7.18
+
+wmsChannel OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem channel"
+ ::= { wirelessModemStatus 19 }
+ --1.3.6.1.4.1.3052.14.1.7.19
+
+wmsCountryCode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem country code"
+ ::= { wirelessModemStatus 20 }
+ --1.3.6.1.4.1.3052.14.1.7.20
+
+wmsNetCode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem network code"
+ ::= { wirelessModemStatus 21 }
+ --1.3.6.1.4.1.3052.14.1.7.21
+
+wmsPLMNColor OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem PLMN color"
+ ::= { wirelessModemStatus 22 }
+ --1.3.6.1.4.1.3052.14.1.7.22
+
+wmsBScolor OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem BS color"
+ ::= { wirelessModemStatus 23 }
+ --1.3.6.1.4.1.3052.14.1.7.23
+
+wmsMpRACH OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem max power RACH"
+ ::= { wirelessModemStatus 24 }
+ --1.3.6.1.4.1.3052.14.1.7.24
+
+wmsMinRxLevel OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem minimum receive level"
+ ::= { wirelessModemStatus 25 }
+ --1.3.6.1.4.1.3052.14.1.7.25
+
+wmsBaseCoeff OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem base coefficient"
+ ::= { wirelessModemStatus 26 }
+ --1.3.6.1.4.1.3052.14.1.7.26
+
+wmsSIMStatus OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "WWireless modem SIM status"
+ ::= { wirelessModemStatus 27 }
+ --1.3.6.1.4.1.3052.14.1.7.27
+
+wmsICCID OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem SIM ICCID"
+ ::= { wirelessModemStatus 28 }
+ --1.3.6.1.4.1.3052.14.1.7.28
+
+wmsModemType OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem type"
+ ::= { wirelessModemStatus 29 }
+ --1.3.6.1.4.1.3052.14.1.7.29
+
+
+--***************************************************************************************
+--AC Power Monitor Section 1.8
+--***************************************************************************************
+
+acpmStatusTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ACPMStatus
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "AC power monitor status table"
+ ::= { acPowerMonitorStatus 1 }
+ --1.3.6.1.4.1.3052.14.1.8.1
+
+acpmStatusEntry OBJECT-TYPE
+ SYNTAX ACPMStatus
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "AC power monitor status table entry"
+ INDEX { acpmsIndex }
+ ::= { acpmStatusTable 1 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1
+
+acpmsIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..6)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for AC power monitors"
+ ::= { acpmStatusEntry 1 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.1
+
+acpmsName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Name for the AC power monitor device."
+ ::= { acpmStatusEntry 2 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.2
+
+acpmsAvgVoltageValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Average voltage, in volts. This is calculated using the formula
+ (register * PT ratio * 0.1). This could be either the average of
+ the phase voltages, or the sum of the phase voltages, depending
+ on device configuration."
+ ::= { acpmStatusEntry 3 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.3
+
+acpmsAvgVoltageMinStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Minimum average voltage value since last reset, in volts."
+ ::= { acpmStatusEntry 4 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.4
+
+acpmsAvgVoltageMaxStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Maximum average voltage value since last reset, in volts."
+ ::= { acpmStatusEntry 5 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.5
+
+acpmsAvgVoltageAvgStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Average average voltage value since last reset, in volts. This is
+ the unit's average of its measurements of the average voltage
+ reported by the AC power monitor device."
+ ::= { acpmStatusEntry 6 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.6
+
+acpmsAvgVoltageInEventState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Event state of this AC power monitor voltage (Low, Normal, High, etc.)."
+ ::= { acpmStatusEntry 7 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.7
+
+acpmsVoltagePhaseAValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Phase A voltage, in volts. This is calculated using the formula
+ (register * PT ratio * 0.1)."
+ ::= { acpmStatusEntry 8 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.8
+
+acpmsVoltagePhaseBValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Phase B voltage, in volts. This is calculated using the formula
+ (register * PT ratio * 0.1)."
+ ::= { acpmStatusEntry 9 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.9
+
+acpmsVoltagePhaseCValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Phase C voltage, in volts. This is calculated using the formula
+ (register * PT ratio * 0.1)."
+ ::= { acpmStatusEntry 10 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.10
+
+acpmsAvgCurrentValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Average current, in amps. This is calculated using the formula
+ (register * CT ratio * 0.001). This could be either the average of
+ the phase currents, or the sum of the phase currents, depending on
+ device configuration."
+ ::= { acpmStatusEntry 11 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.11
+
+acpmsAvgCurrentMinStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Minimum average current value since last reset, in amps."
+ ::= { acpmStatusEntry 12 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.12
+
+acpmsAvgCurrentMaxStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Maximum average current value since last reset, in amps."
+ ::= { acpmStatusEntry 13 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.13
+
+acpmsAvgCurrentAvgStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Average average current value since last reset, in amps. This is
+ the unit's average of its measurements of the average current reported
+ by the AC power monitor device."
+ ::= { acpmStatusEntry 14 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.14
+
+acpmsAvgCurrentInEventState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Event state of this AC power monitor current (Low, Normal, High, etc.)."
+ ::= { acpmStatusEntry 15 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.15
+
+acpmsCurrentPhaseAValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Phase A current, in amps. This is calculated using the formula
+ (register * CT ratio * 0.001)."
+ ::= { acpmStatusEntry 16 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.16
+
+acpmsCurrentPhaseBValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Phase B current, in amps. This is calculated using the formula
+ (register * CT ratio * 0.001)."
+ ::= { acpmStatusEntry 17 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.17
+
+acpmsCurrentPhaseCValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Phase C current, in amps. This is calculated using the formula
+ (register * CT ratio * 0.001)."
+ ::= { acpmStatusEntry 18 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.18
+
+acpmsAvgFreqValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Frequency, in hertz. On the YD2010, this is calculated using the
+ formula (register * 0.00106813). On the WattsOn, this is calculated
+ using the formula (register * 0.1)."
+ ::= { acpmStatusEntry 19 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.19
+
+acpmsAvgFreqMinStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Minimum frequency value since last reset, in hertz."
+ ::= { acpmStatusEntry 20 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.20
+
+acpmsAvgFreqMaxStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Maximum frequency value since last reset, in hertz."
+ ::= { acpmStatusEntry 21 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.21
+
+acpmsAvgFreqAvgStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Average frequency value since last reset, in hertz. This is the
+ unit's average of its measurements of the average frequency reported
+ by the AC power monitor device."
+ ::= { acpmStatusEntry 22 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.22
+
+acpmsAvgFreqInEventState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Event state of this AC power monitor frequency (Low, Normal, High, etc.)."
+ ::= { acpmStatusEntry 23 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.23
+
+acpmsTRPValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total real power, in watts. On the YD2010, this is calculated using
+ the formula (register * PT ratio * CT ratio * Urg * 0.4), where Urg is
+ the voltage range taken from register 0x30A. On the WattsOn models,
+ this is calculated using the formula (register * PT * CT)."
+ ::= { acpmStatusEntry 24 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.24
+
+acpmsTRPMinStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Minimum total real power value since last reset, in watts."
+ ::= { acpmStatusEntry 25 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.25
+
+acpmsTRPMaxStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Maximum total real power value since last reset, in watts."
+ ::= { acpmStatusEntry 26 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.26
+
+acpmsTRPAvgStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Average total real power value since last reset, in watts. This is
+ the unit's average of its measurements of the average total real power
+ reported by the AC power monitor device."
+ ::= { acpmStatusEntry 27 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.27
+
+acpmsTRPInEventState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Event state of this AC power monitor total real power (Low, Normal,
+ High, etc.)."
+ ::= { acpmStatusEntry 28 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.28
+
+acpmsRPPhaseAValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Phase A real power, in watts. On the YD2010, this is calculated using
+ the formula (register * PT ratio * CT ratio * Urg * 0.4), where Urg is
+ the voltage range taken from register 0x30A. On the WattsOn, this is
+ calculated using the formula (register * PT * CT)."
+ ::= { acpmStatusEntry 29 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.29
+
+acpmsRPPhaseBValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Phase B real power, in watts. On the YD2010, this is calculated using
+ the formula (register * PT ratio * CT ratio * Urg * 0.4), where Urg is
+ the voltage range taken from register 0x30A. On the WattsOn, this is
+ calculated using the formula (register * PT * CT)."
+ ::= { acpmStatusEntry 30 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.30
+
+acpmsRPPhaseCValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Phase C real power, in watts. On the YD2010, this is calculated using
+ the formula (register * PT ratio * CT ratio * Urg * 0.4), where Urg is
+ the voltage range taken from register 0x30A. On the WattsOn, this is
+ calculated using the formula (register * PT * CT)."
+ ::= { acpmStatusEntry 31 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.31
+
+acpmsCombined OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ name`deviceState`deviceStateColorCode`voltage`current`frequency`power~voltageEventState`voltageColorCode`currentEventState`currentColorCode`frequencyEventState`freuencyColorCode`powerEventState`powerColorCode"
+ ::= { acpmStatusEntry 32 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.32
+
+acpmsTPFValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total power factor."
+ ::= { acpmStatusEntry 33 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.33
+
+acpmsTPFMinStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total power factor minimum value since last reset."
+ ::= { acpmStatusEntry 34 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.34
+
+acpmsTPFMaxStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total power factor maximum value since last reset."
+ ::= { acpmStatusEntry 35 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.35
+
+acpmsTPFAvgStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total power factor average value since last reset."
+ ::= { acpmStatusEntry 36 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.36
+
+acpmsTPFInEventState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total power factor event state."
+ ::= { acpmStatusEntry 37 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.37
+
+acpmsPFPhaseAValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Phase A power factor."
+ ::= { acpmStatusEntry 38 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.38
+
+acpmsPFPhaseBValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Phase B power factor."
+ ::= { acpmStatusEntry 39 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.39
+
+acpmsPFPhaseCValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Phase C power factor."
+ ::= { acpmStatusEntry 40 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.40
+
+acpmsTRcPValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total reactive power, in VAR."
+ ::= { acpmStatusEntry 41 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.41
+
+acpmsTRcPMinStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total reactive power minimum value since last reset, in VAR."
+ ::= { acpmStatusEntry 42 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.42
+
+acpmsTRcPMaxStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total reactive power maximum value since last reset, in VAR."
+ ::= { acpmStatusEntry 43 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.43
+
+acpmsTRcPAvgStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total reactive power average value since last reset, in VAR."
+ ::= { acpmStatusEntry 44 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.44
+
+acpmsRcPPhaseAValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Phase A reactive power, in VAR."
+ ::= { acpmStatusEntry 45 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.45
+
+acpmsRcPPhaseBValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Phase B reactive power, in VAR."
+ ::= { acpmStatusEntry 46 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.46
+
+acpmsRcPPhaseCValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Phase C reactive power, in VAR."
+ ::= { acpmStatusEntry 47 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.47
+
+acpmsTAPValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total apparent power, in VA."
+ ::= { acpmStatusEntry 48 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.48
+
+acpmsTAPMinStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total apparent power minimum value since last reset, in VA."
+ ::= { acpmStatusEntry 49 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.49
+
+acpmsTAPMaxStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total apparent power maximum value since last reset, in VA."
+ ::= { acpmStatusEntry 50 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.50
+
+acpmsTAPAvgStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total apparent power average value since last reset, in VA."
+ ::= { acpmStatusEntry 51 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.51
+
+acpmsAPPhaseAValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Phase A apparent power, in VA."
+ ::= { acpmStatusEntry 52 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.52
+
+acpmsAPPhaseBValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Phase B apparent power, in VA."
+ ::= { acpmStatusEntry 53 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.53
+
+acpmsAPPhaseCValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Phase C apparent power, in VA."
+ ::= { acpmStatusEntry 54 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.54
+
+acpmsTotalEnergyWh OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total energy, in Wh."
+ ::= { acpmStatusEntry 55 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.55
+
+acpmsTotalEnergyVAR OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total reactive energy, in VAR."
+ ::= { acpmStatusEntry 56 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.56
+
+acpmsTotalEnergyVA OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total apparent energy, in VA."
+ ::= { acpmStatusEntry 57 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.57
+
+
+
+--***************************************************************************************
+--AISG Status Section 1.9
+--***************************************************************************************
+
+aisgsPower OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "AISG power state"
+ ::= { aisgStatus 1 }
+ --1.3.6.1.4.1.3052.14.1.9.1
+
+aisgsBaseStationID OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "AISG base station ID"
+ ::= { aisgStatus 2 }
+ --1.3.6.1.4.1.3052.14.1.9.2
+
+aisgsALDTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AISGALD
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The table of what AISG ALDs (Antenna Line Devices) are attached to the unit."
+ ::= { aisgStatus 3 }
+ --1.3.6.1.4.1.3052.14.1.9.3
+
+aisgsALDEntry OBJECT-TYPE
+ SYNTAX AISGALD
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table entry for AISG ALD table"
+ INDEX { aisgsALDIndex }
+ ::= { aisgsALDTable 1 }
+ --1.3.6.1.4.1.3052.14.1.9.3.1
+
+aisgsALDIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..18)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This number refers to an ALD; it is the ALD # as shown
+ in the web UI and CLI."
+ ::= { aisgsALDEntry 1 }
+ --1.3.6.1.4.1.3052.14.1.9.3.1.1
+
+aisgsALDSectorID OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The sector ID of this ALD."
+ ::= { aisgsALDEntry 2 }
+ --1.3.6.1.4.1.3052.14.1.9.3.1.2
+
+aisgsALDType OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The type of ALD (SR or MR)."
+ ::= { aisgsALDEntry 3 }
+ --1.3.6.1.4.1.3052.14.1.9.3.1.3
+
+aisgsALDDescription OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "User-defined description for this ALD."
+ ::= { aisgsALDEntry 4 }
+ --1.3.6.1.4.1.3052.14.1.9.3.1.4
+
+aisgsALDStatus OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Status of this ALD (i.e., OFF, OK, UNRSP, ALARM)."
+ ::= { aisgsALDEntry 5 }
+ --1.3.6.1.4.1.3052.14.1.9.3.1.5
+
+aisgsALDID OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The ID/serial number of this ALD."
+ ::= { aisgsALDEntry 6 }
+ --1.3.6.1.4.1.3052.14.1.9.3.1.6
+
+aisgsALDTilt OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current tilt value of this ALD."
+ ::= { aisgsALDEntry 7 }
+ --1.3.6.1.4.1.3052.14.1.9.3.1.7
+
+aisgsALDHwVersion OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The hardware version of this ALD."
+ ::= { aisgsALDEntry 8 }
+ --1.3.6.1.4.1.3052.14.1.9.3.1.8
+
+aisgsALDSwVersion OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The software version of this ALD."
+ ::= { aisgsALDEntry 9 }
+ --1.3.6.1.4.1.3052.14.1.9.3.1.9
+
+aisgsALDModel OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The model number of this ALD."
+ ::= { aisgsALDEntry 10 }
+ --1.3.6.1.4.1.3052.14.1.9.3.1.10
+
+aisgsALDAntennaModel OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The model number of the antenna associated with this ALD.
+ Note that not all ALDs have this."
+ ::= { aisgsALDEntry 11 }
+ --1.3.6.1.4.1.3052.14.1.9.3.1.11
+
+aisgsALDMinTilt OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The minimum tilt value of this ALD, as determined by the ALD's
+ loaded configuration file. A nonsensical value here indicates
+ that the ALD is not configured."
+ ::= { aisgsALDEntry 12 }
+ --1.3.6.1.4.1.3052.14.1.9.3.1.12
+
+aisgsALDMaxTilt OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The maximum tilt value of this ALD, as determined by the ALD's
+ loaded configuration file. A nonsensical value here indicates
+ that the ALD is not configured."
+ ::= { aisgsALDEntry 13 }
+ --1.3.6.1.4.1.3052.14.1.9.3.1.13
+
+aisgsALDAISGVersion OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The AISG version of this ALD. E.g., 1.1, 2.0."
+ ::= { aisgsALDEntry 14 }
+ --1.3.6.1.4.1.3052.14.1.9.3.1.14
+
+aisgsFileTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AISGFile
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The table of what AISG files are currently loaded on the unit."
+ ::= { aisgStatus 4 }
+ --1.3.6.1.4.1.3052.14.1.9.4
+
+aisgsFileEntry OBJECT-TYPE
+ SYNTAX AISGFile
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table entry for AISG File table"
+ INDEX { aisgsFileIndex }
+ ::= { aisgsFileTable 1 }
+ --1.3.6.1.4.1.3052.14.1.9.4.1
+
+aisgsFileIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..10)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for AISG File table. This defines the local store (local to
+ the unit) of files residing on the unit that are available to be
+ loaded onto ALDs."
+ ::= { aisgsFileEntry 1 }
+ --1.3.6.1.4.1.3052.14.1.9.4.1.1
+
+aisgsFileName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Name of AISG file (specified by user)."
+ ::= { aisgsFileEntry 2 }
+ --1.3.6.1.4.1.3052.14.1.9.4.1.2
+
+aisgsFileType OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Type of AISG file (e.g., SOFTWARE or CONFIG)"
+ ::= { aisgsFileEntry 3 }
+ --1.3.6.1.4.1.3052.14.1.9.4.1.3
+
+aisgsFileVersion OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Version of AISG file as reported by the ALD running this software.
+ This is for SOFTWARE files, so that the unit can know when (during
+ auto config) it does not need to load software onto an ALD (i.e.,
+ if the ALD already has this software version loaded)."
+ ::= { aisgsFileEntry 4 }
+ --1.3.6.1.4.1.3052.14.1.9.4.1.4
+
+aisgsAutoTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AISGAuto
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The table of AISG automatic configuration slots on the unit. These
+ slots describe what the unit should do automatically (load software,
+ load config, calibrate, tilt) upon finding the ALD during a scan, on
+ the specific basis of any ALD matching the vendor and ALD model defined
+ in a row of this table."
+ ::= { aisgStatus 5 }
+ --1.3.6.1.4.1.3052.14.1.9.5
+
+aisgsAutoEntry OBJECT-TYPE
+ SYNTAX AISGAuto
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table entry for AISG Auto table"
+ INDEX { aisgsAutoIndex }
+ ::= { aisgsAutoTable 1 }
+ --1.3.6.1.4.1.3052.14.1.9.5.1
+
+aisgsAutoIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..10)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for AISG Auto table."
+ ::= { aisgsAutoEntry 1 }
+ --1.3.6.1.4.1.3052.14.1.9.5.1.1
+
+aisgsAutoVendor OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The two-letter vendor code for this automatic configuration table row."
+ ::= { aisgsAutoEntry 2 }
+ --1.3.6.1.4.1.3052.14.1.9.5.1.2
+
+aisgsAutoALDModel OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The ALD model number this automatic configuration table row."
+ ::= { aisgsAutoEntry 3 }
+ --1.3.6.1.4.1.3052.14.1.9.5.1.3
+
+aisgsAutoSoftware OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The software file name of this automatic configuration table row."
+ ::= { aisgsAutoEntry 4 }
+ --1.3.6.1.4.1.3052.14.1.9.5.1.4
+
+aisgsAutoConfig OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The configuration file name of this automatic configuration table row."
+ ::= { aisgsAutoEntry 5 }
+ --1.3.6.1.4.1.3052.14.1.9.5.1.5
+
+aisgsAutoTilt OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The tilt value for this automatic configuration table row. Any ALD not
+ already auto-configured by the unit will be tilted to this value, if its
+ vendor and model number match the vendor and ALD model number of this
+ table row."
+ ::= { aisgsAutoEntry 6 }
+ --1.3.6.1.4.1.3052.14.1.9.5.1.6
+
+
+aisgsAAATable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AISGAAA
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The table of AISG antenna-ALD associations slots on the unit. These
+ slots describe what antenna serial number and what sector ID the unit
+ should assign to an ALD that is undergoing automatic configuration."
+ ::= { aisgStatus 6 }
+ --1.3.6.1.4.1.3052.14.1.9.6
+
+aisgsAAAEntry OBJECT-TYPE
+ SYNTAX AISGAAA
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table entry for AISG AAA table"
+ INDEX { aisgsAAAIndex }
+ ::= { aisgsAAATable 1 }
+ --1.3.6.1.4.1.3052.14.1.9.6.1
+
+aisgsAAAIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..10)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for AISG AAA table."
+ ::= { aisgsAAAEntry 1 }
+ --1.3.6.1.4.1.3052.14.1.9.6.1.1
+
+aisgsAAAALDID OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The ID/serial number of the ALD for this AAA table row."
+ ::= { aisgsAAAEntry 2 }
+ --1.3.6.1.4.1.3052.14.1.9.6.1.2
+
+aisgsAAAAntennaSN OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The user-specified antenna serial number for this AAA table row.
+ An ALD that the unit finds with this ID/serial number will be
+ assigned this antenna serial number. This happens only during
+ auto-configuration of the ALD, which happens only once for an ALD."
+ ::= { aisgsAAAEntry 3 }
+ --1.3.6.1.4.1.3052.14.1.9.6.1.3
+
+aisgsAAASectorID OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The user-specified sector ID for this AAA table row.
+ An ALD that the unit finds with this ID/serial number will be
+ assigned this sector ID. This happens only during auto-configuration
+ of the ALD, which happens only once for an ALD."
+ ::= { aisgsAAAEntry 4 }
+ --1.3.6.1.4.1.3052.14.1.9.6.1.4
+
+
+--***************************************************************************************
+--EventSensor Basics Section 2.1
+--***************************************************************************************
+
+esNumberEventSensors OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of EventSensors recognized by the unit,
+ including the internal EventSensor.
+ Range: 1-17"
+ ::= { eventSensorBasics 1 }
+ --1.3.6.1.4.1.3052.14.2.1.1
+
+esTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ESExist
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The table of what EventSensors are attached to the unit,
+ including the internal EventSensor"
+ ::= { eventSensorBasics 2 }
+ --1.3.6.1.4.1.3052.14.2.1.2
+
+esEntry OBJECT-TYPE
+ SYNTAX ESExist
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table entry for EventSensor table"
+ INDEX { esIndex }
+ ::= { esTable 1 }
+ --1.3.6.1.4.1.3052.14.2.1.2.1
+
+esIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..200)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This number refers to an EventSensor; it has the
+ same meaning as the esIndexES object (see above),
+ except that this object is used only within the
+ esTable branch.
+
+ This object's allowable values are 1 through 16,
+ and 200. 200 always refers to the EventSensor
+ inside the unit. 1 through 16 refer to additional
+ attached EventSensors.
+
+ The number corresponding to an EventSensor is
+ determined by the user at the initial configuration
+ time. If there is an internal sensor in the unit,
+ it will always be the first item in the Sensor
+ Events setup menu.
+
+ For example, if a new EventSensor is configured as
+ the 2nd entry AFTER the internal EventSensor (if
+ one exists) in the Sensor Events Setup Menu, then
+ that EventSensor will be known from then on as
+ EventSensor 2. All point indeces with esIndex=2
+ will now refer to that particular EventSensor.
+ "
+ ::= { esEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.1.2.1.1
+
+esName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The name of the EventSensor"
+ ::= { esEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.1.2.1.2
+
+esID OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The factory-assigned ID of the EventSensor"
+ ::= { esEntry 3 }
+ --1.3.6.1.4.1.3052.14.2.1.2.1.3
+
+esNumberTempSensors OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of temperature sensors on the EventSensor"
+ ::= { esEntry 4 }
+ --1.3.6.1.4.1.3052.14.2.1.2.1.4
+
+esTempReportingMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description of how temperature values should
+ be interpreted."
+ ::= { esEntry 5 }
+ --1.3.6.1.4.1.3052.14.2.1.2.1.5
+
+esNumberCCs OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of contact closures on the EventSensor."
+ ::= { esEntry 6 }
+ --1.3.6.1.4.1.3052.14.2.1.2.1.6
+
+esCCReportingMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description of how CC values should be interpreted."
+ ::= { esEntry 7 }
+ --1.3.6.1.4.1.3052.14.2.1.2.1.7
+
+esNumberHumidSensors OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of humidity sensors on the EventSensor."
+ ::= { esEntry 8 }
+ --1.3.6.1.4.1.3052.14.2.1.2.1.8
+
+esHumidReportingMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description of how humidity sensor values should be
+ interpreted."
+ ::= { esEntry 9 }
+ --1.3.6.1.4.1.3052.14.2.1.2.1.9
+
+esNumberNoiseSensors OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of noise sensors on the EventSensor."
+ ::= { esEntry 10 }
+ --1.3.6.1.4.1.3052.14.2.1.2.1.10
+
+esNoiseReportingMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description of how noise sensor values should be
+ interpreted."
+ ::= { esEntry 11 }
+ --1.3.6.1.4.1.3052.14.2.1.2.1.11
+
+esNumberAirflowSensors OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of airflow sensors on the EventSensor."
+ ::= { esEntry 12 }
+ --1.3.6.1.4.1.3052.14.2.1.2.1.12
+
+esAirflowReportingMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description of how airflow sensor values should be
+ interpreted."
+ ::= { esEntry 13 }
+ --1.3.6.1.4.1.3052.14.2.1.2.1.13
+
+esNumberAnalog OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of analog inputs on the EventSensor."
+ ::= { esEntry 14 }
+ --1.3.6.1.4.1.3052.14.2.1.2.1.14
+
+esAnalogReportingMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description of how analog input values should be
+ interpreted."
+ ::= { esEntry 15 }
+ --1.3.6.1.4.1.3052.14.2.1.2.1.15
+
+esNumberOutputs OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of outputs (relay or power) on the EventSensor"
+ ::= { esEntry 16 }
+ --1.3.6.1.4.1.3052.14.2.1.2.1.16
+
+esOutputReportingMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description of how output values should be interpreted."
+ ::= { esEntry 17 }
+ --1.3.6.1.4.1.3052.14.2.1.2.1.17
+
+esTempCombinedStatus OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ name`value`scale`eventState`eventColorCode"
+ ::= { esEntry 18 }
+ --1.3.6.1.4.1.3052.14.2.1.2.1.18
+
+esCCCombinedStatusBlock1 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ numInBlock~name1`value1`eventColorCode1`alias1~name2`value2`eventColorCode2`alias2~...name8`value8`eventColorCode8`alias8"
+ ::= { esEntry 19 }
+ --1.3.6.1.4.1.3052.14.2.1.2.1.19
+
+esCCCombinedStatusBlock2 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ numInBlock~name9`value9`eventColorCode9`alias9~name10`value10`eventColorCode10`alias10~...name16`value16`eventColorCode16`alias16"
+ ::= { esEntry 20 }
+ --1.3.6.1.4.1.3052.14.2.1.2.1.20
+
+esCCCombinedStatusBlock3 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ numInBlock~name17`value17`eventColorCode17`alias17~name18`value18`eventColorCode18`alias18~...name24`value24`eventColorCode24`alias24"
+ ::= { esEntry 21 }
+ --1.3.6.1.4.1.3052.14.2.1.2.1.21
+
+esCCCombinedStatusBlock4 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ numInBlock~name25`value25`eventColorCode25`alias25~name26`value26`eventColorCode26`alias26~...name32`value32`eventColorCode32`alias32"
+ ::= { esEntry 22 }
+ --1.3.6.1.4.1.3052.14.2.1.2.1.22
+
+esCCCombinedStatusBlock5 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ numInBlock~name33`value33`eventColorCode33`alias33~name34`value34`eventColorCode34`alias35~...name40`value40`eventColorCode40`alias40"
+ ::= { esEntry 23 }
+ --1.3.6.1.4.1.3052.14.2.1.2.1.23
+
+esCCCombinedStatusBlock6 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ numInBlock~name41`value41`eventColorCode41`alias41~name42`value42`eventColorCode42`alias43~...name48`value48`eventColorCode48`alias48"
+ ::= { esEntry 24 }
+ --1.3.6.1.4.1.3052.14.2.1.2.1.24
+
+esCCCombinedStatusBlock7 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ numInBlock~name49`value49`eventColorCode49`alias49~name50`value50`eventColorCode50`alias50~...name56`value56`eventColorCode56`alias56"
+ ::= { esEntry 25 }
+ --1.3.6.1.4.1.3052.14.2.1.2.1.25
+
+esCCCombinedStatusBlock8 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ numInBlock~name57`value57`eventColorCode57`alias57~name57`value57`eventColorCode564`alias57~...name64`value64`eventColorCode64`alias64"
+ ::= { esEntry 26 }
+ --1.3.6.1.4.1.3052.14.2.1.2.1.26
+
+esHumidCombinedStatus OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ name`value`eventState`eventColorCode"
+ ::= { esEntry 27 }
+ --1.3.6.1.4.1.3052.14.2.1.2.1.27
+
+esAnalogCombinedStatusBlock1 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ numInBlock~name1`value1`units1`eventState`eventColorCode1~name2`value2`units2`eventState`eventColorCode2~..."
+ ::= { esEntry 28 }
+ --1.3.6.1.4.1.3052.14.2.1.2.1.28
+
+esAnalogCombinedStatusBlock2 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ numInBlock~name9`value9`units9`eventState9`eventColorCode9~..."
+ ::= { esEntry 29 }
+ --1.3.6.1.4.1.3052.14.2.1.2.1.29
+
+esAnalogCombinedStatusBlock3 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ numInBlock~namex`valuex`unitsx`eventStatex`eventColorCodex~..."
+ ::= { esEntry 30 }
+ --1.3.6.1.4.1.3052.14.2.1.2.1.31
+
+esAnalogCombinedStatusBlock4 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ numInBlock~namex`valuex`unitsx`eventStatex`eventColorCodex~..."
+ ::= { esEntry 31 }
+ --1.3.6.1.4.1.3052.14.2.1.2.1.31
+
+esAnalogCombinedStatusBlock5 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ numInBlock~namex`valuex`unitsx`eventStatex`eventColorCodex~..."
+ ::= { esEntry 32 }
+ --1.3.6.1.4.1.3052.14.2.1.2.1.32
+
+esAnalogCombinedStatusBlock6 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ numInBlock~namex`valuex`unitsx`eventStatex`eventColorCodex~..."
+ ::= { esEntry 33 }
+ --1.3.6.1.4.1.3052.14.2.1.2.1.33
+
+esOutputCombinedStatusBlock1 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ numInBlock~namex`valuex`unitsx`eventStatex`eventColorCodex~..."
+ ::= { esEntry 34 }
+ --1.3.6.1.4.1.3052.14.2.1.2.1.34
+
+esOutputCombinedStatusBlock2 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ numInBlock`namex`valuex`aliasx~namey`valuey`aliasy~...namez`valuez`aliasz"
+ ::= { esEntry 35 }
+ --1.3.6.1.4.1.3052.14.2.1.2.1.35
+
+
+esNewSensors OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "String representing the number of new (attached but unconfigured) EventSensors"
+ ::= { eventSensorBasics 3 }
+ --1.3.6.1.4.1.3052.14.2.1.3
+
+
+--***************************************************************************************
+--EventSensor Point Config Section 2.2
+--***************************************************************************************
+
+
+
+esPointConfigTempTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ESPointConfigTemp
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table organizes 3 basic attributes of temperature
+ sensor points. A point is a particular sensor on an
+ EventSensor. The 3 point attributes organizes in this table
+ are:
+ 1. the configuration item (e.g., enable, name, etc.)
+ 2. the eventsensor on which this point resides
+ 3. the point number (always 1 for temp sensors)
+
+ Points are referenced by a point config index. The point
+ config index is a string of 2 numbers separated by periods.
+ It contains all the information necessary for getting a
+ piece of data off an event sensor within the context of this
+ emperature point config table ; namely, which EventSensor,
+ and which sensor (a.k.a. point) (always 1 for temperature
+ sensors).
+ "
+ ::= { eventSensorPointConfig 1 }
+ --1.3.6.1.4.1.3052.14.2.2.1
+
+esPointConfigTempEntry OBJECT-TYPE
+ SYNTAX ESPointConfigTemp
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for EventSensor point config temperature table"
+ INDEX { espcTempIndexES, espcTempIndexPoint }
+ ::= { esPointConfigTempTable 1 }
+ --1.3.6.1.4.1.3052.14.2.2.1.1
+
+espcTempIndexES OBJECT-TYPE
+ SYNTAX Integer32 (1..200)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The part of the point index that refers to an
+ EventSensor.
+
+ The point config index is a string of 2 numbers separated
+ by a period. It contains all the information
+ necessary for getting a piece of data off an event
+ sensor within the the context of the eventsensor point
+ config temperature table; namely, which EventSensor,
+ and which sensor (a.k.a. point).
+
+ This object's allowable values are 1 through 16,
+ and 200. 200 always refers to the EventSensor
+ inside the unit. 1 through 16 refer to additional
+ attached EventSensors.
+
+ The number corresponding to an EventSensor is
+ determined by the user at the initial configuration
+ time. If there is an internal sensor in the unit,
+ it will always be the first item in the Sensor
+ Events setup menu.
+
+ For example, if a new EventSensor is configured as
+ the 2nd entry AFTER the internal EventSensor (if
+ one exists) in the Sensor Events Setup Menu, then
+ that EventSensor will be known from then on as
+ EventSensor 2. All point indeces with esIndexES=2
+ will now refer to that particular EventSensor.
+ "
+ ::= { esPointConfigTempEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.2.1.1.1
+
+espcTempIndexPoint OBJECT-TYPE
+ SYNTAX Integer32 (1..64)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The part of the point index that delineates which
+ sensor on the EventSensor.
+
+ So this combined with espcTempIndexES (which EventSensor)
+ uniquely defines each point attached to a unit within the
+ context of temperature point configuration."
+ ::= { esPointConfigTempEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.2.1.1.2
+
+espcTempEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable this temperature sensor"
+ ::= { esPointConfigTempEntry 3 }
+ --1.3.6.1.4.1.3052.14.2.2.1.1.3
+
+espcTempScale OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Scale (C/F) for this temperature sensor"
+ ::= { esPointConfigTempEntry 4 }
+ --1.3.6.1.4.1.3052.14.2.2.1.1.4
+
+espcTempDeadband OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Deadband for this temperature sensor (in floating-point format)"
+ ::= { esPointConfigTempEntry 5 }
+ --1.3.6.1.4.1.3052.14.2.2.1.1.5
+
+espcTempVHighTemp OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high temperature event threshold for this temperature
+ sensor (in floating-point format)"
+ ::= { esPointConfigTempEntry 6 }
+ --1.3.6.1.4.1.3052.14.2.2.1.1.6
+
+espcTempVHighActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high temperature event actions for this temperature
+ sensor"
+ ::= { esPointConfigTempEntry 7 }
+ --1.3.6.1.4.1.3052.14.2.2.1.1.7
+
+espcTempVHighTrapnum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high temperature event trap number for this
+ temperature sensor"
+ ::= { esPointConfigTempEntry 8 }
+ --1.3.6.1.4.1.3052.14.2.2.1.1.8
+
+espcTempVHighClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high temperature event class for this temperature
+ sensor"
+ ::= { esPointConfigTempEntry 9 }
+ --1.3.6.1.4.1.3052.14.2.2.1.1.9
+
+espcTempHighTemp OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High temperature event threshold for this temperature
+ sensor (in floating-point format)"
+ ::= { esPointConfigTempEntry 10 }
+ --1.3.6.1.4.1.3052.14.2.2.1.1.10
+
+espcTempHighActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High temperature event actions for this temperature sensor"
+ ::= { esPointConfigTempEntry 11 }
+ --1.3.6.1.4.1.3052.14.2.2.1.1.11
+
+espcTempHighTrapnum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High temperature event trap number for this temperature
+ sensor"
+ ::= { esPointConfigTempEntry 12 }
+ --1.3.6.1.4.1.3052.14.2.2.1.1.12
+
+espcTempHighClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High temperature event class for this temperature sensor"
+ ::= { esPointConfigTempEntry 13 }
+ --1.3.6.1.4.1.3052.14.2.2.1.1.13
+
+espcTempNormalActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return-to-normal event actions for this temperature sensor"
+ ::= { esPointConfigTempEntry 14 }
+ --1.3.6.1.4.1.3052.14.2.2.1.1.14
+
+espcTempNormalTrapnum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return-to-normal event trap number for this temperature
+ sensor"
+ ::= { esPointConfigTempEntry 15 }
+ --1.3.6.1.4.1.3052.14.2.2.1.1.15
+
+espcTempNormalClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return-to-normal event class for this temperature sensor"
+ ::= { esPointConfigTempEntry 16 }
+ --1.3.6.1.4.1.3052.14.2.2.1.1.16
+
+espcTempLowTemp OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low temperature event threshold for this temperature sensor
+ (in floating-point format)"
+ ::= { esPointConfigTempEntry 17 }
+ --1.3.6.1.4.1.3052.14.2.2.1.1.17
+
+espcTempLowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low temperature event actions for this temperature sensor"
+ ::= { esPointConfigTempEntry 18 }
+ --1.3.6.1.4.1.3052.14.2.2.1.1.18
+
+espcTempLowTrapnum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low temperature event trap number for this temperature
+ sensor"
+ ::= { esPointConfigTempEntry 19 }
+ --1.3.6.1.4.1.3052.14.2.2.1.1.19
+
+espcTempLowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low temperature event class for this temperature sensor"
+ ::= { esPointConfigTempEntry 20 }
+ --1.3.6.1.4.1.3052.14.2.2.1.1.20
+
+espcTempVLowTemp OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very Low temperature event threshold for this temperature
+ sensor (in floating-point format)"
+ ::= { esPointConfigTempEntry 21 }
+ --1.3.6.1.4.1.3052.14.2.2.1.1.21
+
+espcTempVLowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very Low temperature event actions for this temperature
+ sensor"
+ ::= { esPointConfigTempEntry 22 }
+ --1.3.6.1.4.1.3052.14.2.2.1.1.22
+
+espcTempVLowTrapnum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very Low temperature event trap number for this temperature
+ sensor"
+ ::= { esPointConfigTempEntry 23 }
+ --1.3.6.1.4.1.3052.14.2.2.1.1.23
+
+espcTempVLowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very Low temperature event class for this temperature sensor"
+ ::= { esPointConfigTempEntry 24 }
+ --1.3.6.1.4.1.3052.14.2.2.1.1.24
+
+
+
+
+
+esPointConfigCCTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ESPointConfigCC
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table organizes 3 basic attributes of contact closure
+ points. A point is a particular sensor on an EventSensor.
+ The 3 point attributes organizes in this table are:
+ 1. the configuration item (e.g., enable, name, etc.)
+ 2. the eventsensor on which this point resides
+ 3. the point number
+
+ Points are referenced by a point config index. The point
+ config index is a string of 2 numbers separated by a period.
+ It contains all the information necessary for getting a piece
+ of data off an event sensor within the context of this
+ contact closure point config table ; namely, which
+ EventSensor and which sensor.
+ "
+ ::= { eventSensorPointConfig 2 }
+ --1.3.6.1.4.1.3052.14.2.2.2
+
+esPointConfigCCEntry OBJECT-TYPE
+ SYNTAX ESPointConfigCC
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for EventSensor point config contact closure table"
+ INDEX { espcCCIndexES, espcCCIndexPoint }
+ ::= { esPointConfigCCTable 1 }
+ --1.3.6.1.4.1.3052.14.2.2.2.1
+
+espcCCIndexES OBJECT-TYPE
+ SYNTAX Integer32 (1..200)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The part of the point index that refers to an
+ EventSensor.
+
+ The point config index is a string of 2 numbers separated
+ by a period. It contains all the information
+ necessary for getting a piece of data off an event
+ sensor within the the context of the eventsensor point
+ config contact closure table; namely, which EventSensor
+ and which sensor (a.k.a. point).
+
+ This object's allowable values are 1 through 16,
+ and 200. 200 always refers to the EventSensor
+ inside the unit. 1 through 16 refer to additional
+ attached EventSensors.
+ "
+ ::= { esPointConfigCCEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.2.2.1.1
+
+espcCCIndexPoint OBJECT-TYPE
+ SYNTAX Integer32 (1..64)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The part of the point index that delineates which
+ sensor on the EventSensor.
+
+ So this combined with espcCCIndexES (which EventSensor)
+ uniquely defines each point attached to a unit within the
+ context of contact closure point configuration."
+ ::= { esPointConfigCCEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.2.2.1.2
+
+espcCCEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable for this contact closure"
+ ::= { esPointConfigCCEntry 3 }
+ --1.3.6.1.4.1.3052.14.2.2.2.1.3
+
+espcCCName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Name for this contact closure"
+ ::= { esPointConfigCCEntry 4 }
+ --1.3.6.1.4.1.3052.14.2.2.2.1.4
+
+espcCCEventState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Event state for this contact closure"
+ ::= { esPointConfigCCEntry 5 }
+ --1.3.6.1.4.1.3052.14.2.2.2.1.5
+
+espcCCThreshold OBJECT-TYPE
+ SYNTAX Integer32 (0..65535)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Event threshold (seconds) for this contact closure"
+ ::= { esPointConfigCCEntry 6 }
+ --1.3.6.1.4.1.3052.14.2.2.2.1.6
+
+espcCCEventActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Event actions for this contact closure"
+ ::= { esPointConfigCCEntry 7 }
+ --1.3.6.1.4.1.3052.14.2.2.2.1.7
+
+espcCCEventTrapnum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Event trap number for this contact closure"
+ ::= { esPointConfigCCEntry 8 }
+ --1.3.6.1.4.1.3052.14.2.2.2.1.8
+
+espcCCEventClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Event class for this contact closure"
+ ::= { esPointConfigCCEntry 9 }
+ --1.3.6.1.4.1.3052.14.2.2.2.1.9
+
+espcCCNormalActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return-to-normal actions for this contact closure"
+ ::= { esPointConfigCCEntry 10 }
+ --1.3.6.1.4.1.3052.14.2.2.2.1.10
+
+espcCCNormalTrapnum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return-to-normal trap number for this contact closure"
+ ::= { esPointConfigCCEntry 11 }
+ --1.3.6.1.4.1.3052.14.2.2.2.1.11
+
+espcCCNormalClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return-to-normal class for this contact closure"
+ ::= { esPointConfigCCEntry 12 }
+ --1.3.6.1.4.1.3052.14.2.2.2.1.12
+
+espcCCAlarmAlias OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Event alias for this contact closure"
+ ::= { esPointConfigCCEntry 13 }
+ --1.3.6.1.4.1.3052.14.2.2.2.1.13
+
+espcCCNormalAlias OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return-to-normal alias for this contact closure"
+ ::= { esPointConfigCCEntry 14 }
+ --1.3.6.1.4.1.3052.14.2.2.2.1.14
+
+espcCCNormalThreshold OBJECT-TYPE
+ SYNTAX Integer32 (0..65535)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Event threshold (seconds) for this contact closure to return to normal"
+ ::= { esPointConfigCCEntry 15 }
+ --1.3.6.1.4.1.3052.14.2.2.2.1.15
+
+espcCCOverrideGlobalReminder OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Override global reminder interval (evReminderInterval) for this CC."
+ ::= { esPointConfigCCEntry 16 }
+ --1.3.6.1.4.1.3052.14.2.2.2.1.16
+
+espcCCReminderInterval OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Individual reminder interval for this CC, applicable when the global
+ reminder is overriden."
+ ::= { esPointConfigCCEntry 17 }
+ --1.3.6.1.4.1.3052.14.2.2.2.1.17
+
+
+esPointConfigHumidTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ESPointConfigHumid
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table organizes 3 basic attributes of humidity points.
+ A point is a particular sensor on an EventSensor. The 3
+ point attributes organizes in this table are:
+ 1. the configuration item (e.g., enable, name, etc.)
+ 2. the eventsensor on which this point resides
+ 3. the point number (always 1 for humidity sensors)
+
+ Points are referenced by a point config index. The point
+ config index is a string of 2 numbers separated by a period.
+ It contains all the information necessary for getting a piece
+ of data off an event sensor within the context of this
+ humidity point config table ; namely, which EventSensor and
+ which sensor.
+ "
+ ::= { eventSensorPointConfig 3 }
+ --1.3.6.1.4.1.3052.14.2.2.3
+
+esPointConfigHumidEntry OBJECT-TYPE
+ SYNTAX ESPointConfigHumid
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for EventSensor point config humidity table"
+ INDEX { espcHumidIndexES, espcHumidIndexPoint }
+ ::= { esPointConfigHumidTable 1 }
+ --1.3.6.1.4.1.3052.14.2.2.3.1
+
+espcHumidIndexES OBJECT-TYPE
+ SYNTAX Integer32 (1..200)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The part of the point index that refers to an
+ EventSensor.
+
+ The point config index is a string of 2 numbers separated
+ by a period. It contains all the information
+ necessary for getting a piece of data off an event
+ sensor within the the context of the eventsensor point
+ config contact closure table; namely, which EventSensor
+ and which sensor (a.k.a. point).
+
+ This object's allowable values are 1 through 16,
+ and 200. 200 always refers to the EventSensor
+ inside the unit. 1 through 16 refer to additional
+ attached EventSensors.
+ "
+ ::= { esPointConfigHumidEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.2.3.1.1
+
+espcHumidIndexPoint OBJECT-TYPE
+ SYNTAX Integer32 (1..64)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The part of the point index that delineates which
+ sensor on the EventSensor.
+
+ So this combined with espcHumidIndexES (which EventSensor)
+ uniquely defines each point attached to a unit within the
+ context of contact closure point configuration."
+ ::= { esPointConfigHumidEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.2.3.1.2
+
+espcHumidEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable for this humidity sensor"
+ ::= { esPointConfigHumidEntry 3 }
+ --1.3.6.1.4.1.3052.14.2.2.3.1.3
+
+espcHumidDeadband OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Deadband for this humidity sensor"
+ ::= { esPointConfigHumidEntry 4 }
+ --1.3.6.1.4.1.3052.14.2.2.3.1.4
+
+espcHumidVHighHumid OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event threshold for this humidity sensor"
+ ::= { esPointConfigHumidEntry 5 }
+ --1.3.6.1.4.1.3052.14.2.2.3.1.5
+
+espcHumidVHighActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event actions for this humidity sensor"
+ ::= { esPointConfigHumidEntry 6 }
+ --1.3.6.1.4.1.3052.14.2.2.3.1.6
+
+espcHumidVHighTrapnum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event trap number for this humidity sensor"
+ ::= { esPointConfigHumidEntry 7 }
+ --1.3.6.1.4.1.3052.14.2.2.3.1.7
+
+espcHumidVHighClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event class for this humidity sensor"
+ ::= { esPointConfigHumidEntry 8 }
+ --1.3.6.1.4.1.3052.14.2.2.3.1.8
+
+espcHumidHighHumid OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event threshold for this humidity sensor"
+ ::= { esPointConfigHumidEntry 9 }
+ --1.3.6.1.4.1.3052.14.2.2.3.1.9
+
+espcHumidHighActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event actions for this humidity sensor"
+ ::= { esPointConfigHumidEntry 10 }
+ --1.3.6.1.4.1.3052.14.2.2.3.1.10
+
+espcHumidHighTrapnum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event trap number for this humidity sensor"
+ ::= { esPointConfigHumidEntry 11 }
+ --1.3.6.1.4.1.3052.14.2.2.3.1.11
+
+espcHumidHighClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event class for this humidity sensor"
+ ::= { esPointConfigHumidEntry 12 }
+ --1.3.6.1.4.1.3052.14.2.2.3.1.12
+
+espcHumidNormalActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return-to-normal actions for this humidity sensor"
+ ::= { esPointConfigHumidEntry 13 }
+ --1.3.6.1.4.1.3052.14.2.2.3.1.13
+
+espcHumidNormalTrapnum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return-to-normal trap number for this humidity sensor"
+ ::= { esPointConfigHumidEntry 14 }
+ --1.3.6.1.4.1.3052.14.2.2.3.1.14
+
+espcHumidNormalClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return-to-normal class for this humidity sensor"
+ ::= { esPointConfigHumidEntry 15 }
+ --1.3.6.1.4.1.3052.14.2.2.3.1.15
+
+espcHumidLowHumid OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event threshold for this humidity sensor"
+ ::= { esPointConfigHumidEntry 16 }
+ --1.3.6.1.4.1.3052.14.2.2.3.1.16
+
+espcHumidLowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event actions for this humidity sensor"
+ ::= { esPointConfigHumidEntry 17 }
+ --1.3.6.1.4.1.3052.14.2.2.3.1.17
+
+espcHumidLowTrapnum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event trap number for this humidity sensor"
+ ::= { esPointConfigHumidEntry 18 }
+ --1.3.6.1.4.1.3052.14.2.2.3.1.18
+
+espcHumidLowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event class for this humidity sensor"
+ ::= { esPointConfigHumidEntry 19 }
+ --1.3.6.1.4.1.3052.14.2.2.3.1.19
+
+espcHumidVLowHumid OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event threshold for this humidity sensor"
+ ::= { esPointConfigHumidEntry 20 }
+ --1.3.6.1.4.1.3052.14.2.2.3.1.20
+
+espcHumidVLowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event actions for this humidity sensor"
+ ::= { esPointConfigHumidEntry 21 }
+ --1.3.6.1.4.1.3052.14.2.2.3.1.21
+
+espcHumidVLowTrapnum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event trap number for this humidity sensor"
+ ::= { esPointConfigHumidEntry 22 }
+ --1.3.6.1.4.1.3052.14.2.2.3.1.22
+
+espcHumidVLowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event class for this humidity sensor"
+ ::= { esPointConfigHumidEntry 23 }
+ --1.3.6.1.4.1.3052.14.2.2.3.1.23
+
+
+esPointConfigAITable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ESPointConfigAnalogInput
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table organizes 3 basic attributes of analog input
+ points. A point is a particular sensor on an EventSensor.
+ The 3 point attributes organizes in this table are:
+ 1. the configuration item (e.g., enable, name, etc.)
+ 2. the eventsensor on which this point resides
+ 3. the point number
+
+ Points are referenced by a point config index. The point
+ config index is a string of 2 numbers separated by a period.
+ It contains all the information necessary for getting a
+ piece of data off an event sensor within the context of this
+ analog input point config table ; namely, which EventSensor
+ and which sensor.
+ "
+ ::= { eventSensorPointConfig 5 }
+ --1.3.6.1.4.1.3052.14.2.2.5
+
+esPointConfigAIEntry OBJECT-TYPE
+ SYNTAX ESPointConfigAnalogInput
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for EventSensor point config analog input table"
+ INDEX { espcHumidIndexES, espcHumidIndexPoint }
+ ::= { esPointConfigAITable 1 }
+ --1.3.6.1.4.1.3052.14.2.2.5.1
+
+espcAIIndexES OBJECT-TYPE
+ SYNTAX Integer32 (1..200)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The part of the point index that refers to an
+ EventSensor.
+
+ The point config index is a string of 2 numbers separated
+ by a period. It contains all the information
+ necessary for getting a piece of data off an event
+ sensor within the the context of the eventsensor point
+ config contact closure table; namely, which EventSensor
+ and which sensor (a.k.a. point).
+
+ This object's allowable values are 1 through 16,
+ and 200. 200 always refers to the EventSensor
+ inside the unit. 1 through 16 refer to additional
+ attached EventSensors.
+ "
+ ::= { esPointConfigAIEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.2.5.1.1
+
+espcAIIndexPoint OBJECT-TYPE
+ SYNTAX Integer32 (1..64)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The part of the point index that delineates which
+ sensor on the EventSensor.
+
+ So this combined with espcAIIndexES (which EventSensor)
+ uniquely defines each point attached to a unit within the
+ context of contact closure point configuration."
+ ::= { esPointConfigAIEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.2.5.1.2
+
+espcAIEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF for this analog input sensor"
+ ::= { esPointConfigAIEntry 3 }
+ --1.3.6.1.4.1.3052.14.2.2.5.1.3
+
+espcAIDeadband OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Deadband for this analog input sensor"
+ ::= { esPointConfigAIEntry 5 }
+ --1.3.6.1.4.1.3052.14.2.2.5.1.5
+
+espcAIVhighValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event threshold (decivolts or tenths of
+ milliamps) for this analog input sensor"
+ ::= { esPointConfigAIEntry 6 }
+ --1.3.6.1.4.1.3052.14.2.2.5.1.6
+
+espcAIVhighActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event actions for this analog input sensor"
+ ::= { esPointConfigAIEntry 7 }
+ --1.3.6.1.4.1.3052.14.2.2.5.1.7
+
+espcAIVhighTrapnum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event trap number for this analog input sensor"
+ ::= { esPointConfigAIEntry 8 }
+ --1.3.6.1.4.1.3052.14.2.2.5.1.8
+
+espcAIVhighClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event class for this analog input sensor"
+ ::= { esPointConfigAIEntry 9 }
+ --1.3.6.1.4.1.3052.14.2.2.5.1.9
+
+espcAIHighValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event threshold (decivolts or tenths of milliamps) for
+ this analog input sensor"
+ ::= { esPointConfigAIEntry 10 }
+ --1.3.6.1.4.1.3052.14.2.2.5.1.10
+
+espcAIHighActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event actions for this analog input sensor"
+ ::= { esPointConfigAIEntry 11 }
+ --1.3.6.1.4.1.3052.14.2.2.5.1.11
+
+espcAIHighTrapnum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event trap number for this analog input sensor"
+ ::= { esPointConfigAIEntry 12 }
+ --1.3.6.1.4.1.3052.14.2.2.5.1.12
+
+espcAIHighClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event class for this analog input sensor"
+ ::= { esPointConfigAIEntry 13 }
+ --1.3.6.1.4.1.3052.14.2.2.5.1.13
+
+espcAINormalActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return-to-normal actions for this analog input sensor"
+ ::= { esPointConfigAIEntry 14 }
+ --1.3.6.1.4.1.3052.14.2.2.5.1.14
+
+espcAINormalTrapnum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return-to-normal trap number for this analog input sensor"
+ ::= { esPointConfigAIEntry 15 }
+ --1.3.6.1.4.1.3052.14.2.2.5.1.15
+
+espcAINormalClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return-to-normal class for this analog input sensor"
+ ::= { esPointConfigAIEntry 16 }
+ --1.3.6.1.4.1.3052.14.2.2.5.1.16
+
+espcAILowValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event threshold (decivolts or tenths of milliamps) for
+ this analog input sensor"
+ ::= { esPointConfigAIEntry 17 }
+ --1.3.6.1.4.1.3052.14.2.2.5.1.17
+
+espcAILowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event actions for this analog input sensor"
+ ::= { esPointConfigAIEntry 18 }
+ --1.3.6.1.4.1.3052.14.2.2.5.1.18
+
+espcAILowTrapnum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event trap number for this analog input sensor"
+ ::= { esPointConfigAIEntry 19 }
+ --1.3.6.1.4.1.3052.14.2.2.5.1.19
+
+espcAILowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event class for this analog input sensor"
+ ::= { esPointConfigAIEntry 20 }
+ --1.3.6.1.4.1.3052.14.2.2.5.1.20
+
+espcAIVlowValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event threshold (decivolts or tenths of milliamps)
+ for this analog input sensor"
+ ::= { esPointConfigAIEntry 21 }
+ --1.3.6.1.4.1.3052.14.2.2.5.1.21
+
+espcAIVlowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event actions for this analog input sensor"
+ ::= { esPointConfigAIEntry 22 }
+ --1.3.6.1.4.1.3052.14.2.2.5.1.22
+
+espcAIVlowTrapnum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event actions for this analog input sensor"
+ ::= { esPointConfigAIEntry 23 }
+ --1.3.6.1.4.1.3052.14.2.2.5.1.23
+
+espcAIVlowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event class for this analog input sensor"
+ ::= { esPointConfigAIEntry 24 }
+ --1.3.6.1.4.1.3052.14.2.2.5.1.24
+
+espcAIConvUnitName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Converstion unit name for this analog input sensor"
+ ::= { esPointConfigAIEntry 25 }
+ --1.3.6.1.4.1.3052.14.2.2.5.1.25
+
+espcAIConvHighValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Conversion high value for this analog input sensor"
+ ::= { esPointConfigAIEntry 26 }
+ --1.3.6.1.4.1.3052.14.2.2.5.1.26
+
+espcAIConvHighUnit OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Conversion high unit value for this analog input sensor"
+ ::= { esPointConfigAIEntry 27 }
+ --1.3.6.1.4.1.3052.14.2.2.5.1.27
+
+espcAIConvLowValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Conversion low value for this analog input sensor"
+ ::= { esPointConfigAIEntry 29 }
+ --1.3.6.1.4.1.3052.14.2.2.5.1.29
+
+espcAIConvLowUnit OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Conversion unit low unit value for this analog input sensor"
+ ::= { esPointConfigAIEntry 30 }
+ --1.3.6.1.4.1.3052.14.2.2.5.1.30
+
+espcAIDisplayFormat OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Analog input display format"
+ ::= { esPointConfigAIEntry 32 }
+ --1.3.6.1.4.1.3052.14.2.2.5.1.32
+
+esPointConfigOutputTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ESPointConfigOutput
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table organizes configuration items for output
+ points. A point is a particular sensor on an EventSensor.
+ The 3 point attributes organized in this table are:
+ 1. the configuration item (e.g., enable, name, etc.)
+ 2. the eventsensor on which this point resides
+ 3. the point number
+
+ Points are referenced by a point config index. The point
+ config index is a string of 2 numbers separated by a period.
+ It contains all the information necessary for getting a
+ piece of data off an event sensor within the context of this
+ output config table ; namely, which EventSensor
+ and which sensor.
+ "
+ ::= { eventSensorPointConfig 6 }
+ --1.3.6.1.4.1.3052.14.2.2.6
+
+esPointConfigOutputEntry OBJECT-TYPE
+ SYNTAX ESPointConfigOutput
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for EventSensor point config output table"
+ INDEX { espcOutputIndexES, espcOutputIndexPoint }
+ ::= { esPointConfigOutputTable 1 }
+ --1.3.6.1.4.1.3052.14.2.2.6.1
+
+espcOutputIndexES OBJECT-TYPE
+ SYNTAX Integer32 (1..200)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The part of the point index that refers to an
+ EventSensor.
+
+ The point config index is a string of 2 numbers separated
+ by a period. It contains all the information
+ necessary for getting a piece of data off an event
+ sensor within the the context of the eventsensor point
+ config contact closure table; namely, which EventSensor
+ and which sensor (a.k.a. point).
+
+ This object's allowable values are 1 through 16,
+ and 200. 200 always refers to the EventSensor
+ inside the unit. 1 through 16 refer to additional
+ attached EventSensors.
+ "
+ ::= { esPointConfigOutputEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.2.6.1.1
+
+espcOutputIndexPoint OBJECT-TYPE
+ SYNTAX Integer32 (1..64)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The part of the point index that delineates which
+ sensor on the EventSensor.
+
+ So this combined with espcOutputIndexES (which EventSensor)
+ uniquely defines each point attached to a unit within the
+ context of output point configuration."
+ ::= { esPointConfigOutputEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.2.6.1.2
+
+espcOutputEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enables the output event for this output. This has no effect
+ on whether the relay changes state, only on whether a state change
+ triggers an event."
+ ::= { esPointConfigOutputEntry 3 }
+ --1.3.6.1.4.1.3052.14.2.2.6.1.3
+
+espcOutputActiveState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Which state is considered the active state: energized/de-energized."
+ ::= { esPointConfigOutputEntry 4 }
+ --1.3.6.1.4.1.3052.14.2.2.6.1.4
+
+espcOutputType OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Output type: RELAY, POWER, SSR, TTL."
+ ::= { esPointConfigOutputEntry 5 }
+ --1.3.6.1.4.1.3052.14.2.2.6.1.5
+
+espcOutputAliasValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Output alias corresponding to its event state."
+ ::= { esPointConfigOutputEntry 6 }
+ --1.3.6.1.4.1.3052.14.2.2.6.1.6
+
+espcOutputAliasColor OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Output color corresponding to its event state."
+ ::= { esPointConfigOutputEntry 7 }
+ --1.3.6.1.4.1.3052.14.2.2.6.1.7
+
+espcOutputActiveAlias OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Alias for the output active state."
+ ::= { esPointConfigOutputEntry 10 }
+ --1.3.6.1.4.1.3052.14.2.2.6.1.10
+
+espcOutputActiveColor OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Output color (as rendered in the web UI, in RGB hex format) corresponding
+ to the output active state."
+ ::= { esPointConfigOutputEntry 11 }
+ --1.3.6.1.4.1.3052.14.2.2.6.1.11
+
+espcOutputActiveActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Actions for the output active event."
+ ::= { esPointConfigOutputEntry 12 }
+ --1.3.6.1.4.1.3052.14.2.2.6.1.12
+
+espcOutputActiveTrapnum OBJECT-TYPE
+ SYNTAX Integer32 (150..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Actions for the output active event."
+ ::= { esPointConfigOutputEntry 13 }
+ --1.3.6.1.4.1.3052.14.2.2.6.1.13
+
+espcOutputActiveClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Class (severity) for the output active event."
+ ::= { esPointConfigOutputEntry 14 }
+ --1.3.6.1.4.1.3052.14.2.2.6.1.14
+
+espcOutputInactiveAlias OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Alias for the output inactive state."
+ ::= { esPointConfigOutputEntry 20 }
+ --1.3.6.1.4.1.3052.14.2.2.6.1.20
+
+espcOutputInactiveColor OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Output color (as rendered in the web UI, in RGB hex format) corresponding
+ to the output inactive state."
+ ::= { esPointConfigOutputEntry 21 }
+ --1.3.6.1.4.1.3052.14.2.2.6.1.21
+
+espcOutputInactiveActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Actions for the output inactive event."
+ ::= { esPointConfigOutputEntry 22 }
+ --1.3.6.1.4.1.3052.14.2.2.6.1.22
+
+espcOutputInactiveTrapnum OBJECT-TYPE
+ SYNTAX Integer32 (150..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Actions for the output inactive event."
+ ::= { esPointConfigOutputEntry 23 }
+ --1.3.6.1.4.1.3052.14.2.2.6.1.23
+
+espcOutputInactiveClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Class (severity) for the output inactive event."
+ ::= { esPointConfigOutputEntry 24 }
+ --1.3.6.1.4.1.3052.14.2.2.6.1.24
+
+
+--***************************************************************************************
+--Serial Port Section 2.3
+--***************************************************************************************
+
+numberPorts OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of RS-232 ports found.
+ Range: 2 or 4"
+ ::= { serialPorts 1 }
+ --1.3.6.1.4.1.3052.14.2.3.1
+
+portConfigTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PortConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Port config table"
+ ::= { serialPorts 2 }
+ --1.3.6.1.4.1.3052.14.2.3.2
+
+portConfigEntry OBJECT-TYPE
+ SYNTAX PortConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Port config entry"
+ INDEX { portConfigIndex }
+ ::= { portConfigTable 1 }
+ --1.3.6.1.4.1.3052.14.2.3.2.1
+
+portConfigIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..16)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for ports"
+ ::= { portConfigEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.3.2.1.1
+
+portConfigBaud OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Baud rate, 19200, 9600, etc."
+ ::= { portConfigEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.3.2.1.2
+
+portConfigDataFormat OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Value representing word length, parity, and
+ stop bits: 0=8N1, 1=7E1, 2=7O1, 3=7N1, 4=8O2"
+ ::= { portConfigEntry 3 }
+ --1.3.6.1.4.1.3052.14.2.3.2.1.3
+
+portConfigStripPtOutputLfs OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Strip passthrough LFs sent to device on this port:
+ 1=yes, 0=no."
+ ::= { portConfigEntry 4 }
+ --1.3.6.1.4.1.3052.14.2.3.2.1.4
+
+portConfigStripPtInputLfs OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Strip passthrough LFs received from device on this
+ port: 1=yes, 0=no."
+ ::= { portConfigEntry 5 }
+ --1.3.6.1.4.1.3052.14.2.3.2.1.5
+
+portConfigMaskEnable OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "1=Use the character mask on this port. 0=Do
+ not use the mask. When the mask is enabled,
+ the following ASCII characters are ignored
+ on the port:
+ 0, 1, 4-9, 11, 12, 14-31, 128-255.
+ When the mask is disabled, all characters are
+ accepted on the port."
+ ::= { portConfigEntry 7 }
+ --1.3.6.1.4.1.3052.14.2.3.2.1.7
+
+portConfigDAEnable OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "1=Enable the Data Alarm Evaluator for data
+ on this port. 0=Do not evaluate data on this
+ port."
+ ::= { portConfigEntry 8 }
+ --1.3.6.1.4.1.3052.14.2.3.2.1.8
+
+portConfigStoreAlarmsDPT OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF: store alarms received during passthrough"
+ ::= { portConfigEntry 9 }
+ --1.3.6.1.4.1.3052.14.2.3.2.1.9
+
+portConfigRecordTimeout OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Timeout after last unterminated data received upon
+ which data collected so far is stored as a record."
+ ::= { portConfigEntry 10 }
+ --1.3.6.1.4.1.3052.14.2.3.2.1.10
+
+portConfigDataType OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "How the port interprets incoming data: ASCII/BINARY"
+ ::= { portConfigEntry 11 }
+ --1.3.6.1.4.1.3052.14.2.3.2.1.11
+
+portConfigEtxToCRLF OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF whether the port translates incoming ETX to CRLF"
+ ::= { portConfigEntry 12 }
+ --1.3.6.1.4.1.3052.14.2.3.2.1.12
+
+portConfigMLREnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF Whether Multiline Records are collected on this port."
+ ::= { portConfigEntry 13 }
+ --1.3.6.1.4.1.3052.14.2.3.2.1.13
+
+portConfigMLRStartField1Pos OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Position of MLR start field 1"
+ ::= { portConfigEntry 14 }
+ --1.3.6.1.4.1.3052.14.2.3.2.1.14
+
+portConfigMLRStartField1Text OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Text to match MLR start field 1"
+ ::= { portConfigEntry 15 }
+ --1.3.6.1.4.1.3052.14.2.3.2.1.15
+
+portConfigMLRStartField2Pos OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Position of MLR start field 2"
+ ::= { portConfigEntry 16 }
+ --1.3.6.1.4.1.3052.14.2.3.2.1.16
+
+portConfigMLRStartField2Text OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Text to match MLR start field 2"
+ ::= { portConfigEntry 17 }
+ --1.3.6.1.4.1.3052.14.2.3.2.1.17
+
+portConfigMLRNumLinesBefore OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number of lines before the starting line which should
+ be included in the MLR"
+ ::= { portConfigEntry 18 }
+ --1.3.6.1.4.1.3052.14.2.3.2.1.18
+
+portConfigMLREndDetection OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "How the MLR parser determines what ends an MLR: by FORMULA,
+ number of lines received so far (COUNT), or number of blank
+ lines received so far (BLANKS)"
+ ::= { portConfigEntry 19 }
+ --1.3.6.1.4.1.3052.14.2.3.2.1.19
+
+portConfigMLRLineCount OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number of lines in the MLR (used by the end detection mode)"
+ ::= { portConfigEntry 20 }
+ --1.3.6.1.4.1.3052.14.2.3.2.1.20
+
+portConfigMLREndField1Pos OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Position of MLR end field 1"
+ ::= { portConfigEntry 21 }
+ --1.3.6.1.4.1.3052.14.2.3.2.1.21
+
+portConfigMLREndField1Text OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Text to match MLR end field 1"
+ ::= { portConfigEntry 22 }
+ --1.3.6.1.4.1.3052.14.2.3.2.1.22
+
+portConfigMLREndField2Pos OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Position of MLR end field 2"
+ ::= { portConfigEntry 23 }
+ --1.3.6.1.4.1.3052.14.2.3.2.1.23
+
+portConfigMLREndField2Text OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Text to match MLR end field 2"
+ ::= { portConfigEntry 24 }
+ --1.3.6.1.4.1.3052.14.2.3.2.1.24
+
+portConfigMLRUseComplexRules OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF MLR parser uses complex rules (field possitions/
+ formulas, etc.)"
+ ::= { portConfigEntry 25 }
+ --1.3.6.1.4.1.3052.14.2.3.2.1.25
+
+portConfigBufferPT OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF records received during passthrough mode are
+ buffered/stored in the database"
+ ::= { portConfigEntry 26 }
+ --1.3.6.1.4.1.3052.14.2.3.2.1.26
+
+portConfigId OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The text identifer for the port"
+ ::= { portConfigEntry 27 }
+ --1.3.6.1.4.1.3052.14.2.3.2.1.27
+
+portConfigMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Mode of the serial port."
+ ::= { portConfigEntry 28 }
+ --1.3.6.1.4.1.3052.14.2.3.2.1.28
+
+portConfigHsk OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Handshaking mode of the serial port."
+ ::= { portConfigEntry 29 }
+ --1.3.6.1.4.1.3052.14.2.3.2.1.29
+
+--***************************************************************************************
+--Network Section 2.4
+--***************************************************************************************
+
+eth1Mode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Mode of the Ethernet1 interface: STATIC,DHCP,VLAN"
+ ::= { ethernet1 1 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.1
+
+eth1Address OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 IP address"
+ ::= { ethernet1 2 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.2
+
+eth1SubnetMask OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 subnet mask"
+ ::= { ethernet1 3 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.3
+
+eth1Router OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 router"
+ ::= { ethernet1 4 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.4
+
+-- Ethernet1 VLAN1
+
+eth1VLAN1ID OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN1 ID"
+ ::= { eth1VLAN1 1 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.5.1.1
+
+eth1VLAN1Priority OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN1 priority"
+ ::= { eth1VLAN1 2 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.5.1.2
+
+eth1VLAN1Address OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN1 IP address"
+ ::= { eth1VLAN1 3 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.5.1.3
+
+eth1VLAN1SubnetMask OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN1 subnet mask"
+ ::= { eth1VLAN1 4 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.5.1.4
+
+eth1VLAN1Router OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN1 router"
+ ::= { eth1VLAN1 5 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.5.1.5
+
+-- Ethernet1 VLAN2
+
+eth1VLAN2ID OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN2 ID"
+ ::= { eth1VLAN2 1 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.5.2.1
+
+eth1VLAN2Priority OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN2 priority"
+ ::= { eth1VLAN2 2 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.5.2.2
+
+eth1VLAN2Address OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN2 IP address"
+ ::= { eth1VLAN2 3 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.5.2.3
+
+eth1VLAN2SubnetMask OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN2 subnet mask"
+ ::= { eth1VLAN2 4 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.5.2.4
+
+eth1VLAN2Router OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN2 router"
+ ::= { eth1VLAN2 5 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.5.2.5
+
+-- Ethernet1 VLAN3
+
+eth1VLAN3ID OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN3 ID"
+ ::= { eth1VLAN3 1 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.5.3.1
+
+eth1VLAN3Priority OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN3 priority"
+ ::= { eth1VLAN3 2 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.5.3.2
+
+eth1VLAN3Address OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN3 IP address"
+ ::= { eth1VLAN3 3 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.5.3.3
+
+eth1VLAN3SubnetMask OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN3 subnet mask"
+ ::= { eth1VLAN3 4 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.5.3.4
+
+eth1VLAN3Router OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN3 router"
+ ::= { eth1VLAN3 5 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.5.3.5
+
+-- Ethernet1 VLAN4
+
+eth1VLAN4ID OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN4 ID"
+ ::= { eth1VLAN4 1 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.5.4.1
+
+eth1VLAN4Priority OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN4 priority"
+ ::= { eth1VLAN4 2 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.5.4.2
+
+eth1VLAN4Address OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN4 IP address"
+ ::= { eth1VLAN4 3 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.5.4.3
+
+eth1VLAN4SubnetMask OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN4 subnet mask"
+ ::= { eth1VLAN4 4 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.5.4.4
+
+eth1VLAN4Router OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN4 router"
+ ::= { eth1VLAN4 5 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.5.4.5
+
+-- Ethernet1 VLAN5
+
+eth1VLAN5ID OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN5 ID"
+ ::= { eth1VLAN5 1 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.5.5.1
+
+eth1VLAN5Priority OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN5 priority"
+ ::= { eth1VLAN5 2 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.5.5.2
+
+eth1VLAN5Address OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN5 IP address"
+ ::= { eth1VLAN5 3 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.5.5.3
+
+eth1VLAN5SubnetMask OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN5 subnet mask"
+ ::= { eth1VLAN5 4 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.5.5.4
+
+eth1VLAN5Router OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN5 router"
+ ::= { eth1VLAN5 5 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.5.5.5
+
+-- Ethernet1 VLAN6
+
+eth1VLAN6ID OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN6 ID"
+ ::= { eth1VLAN6 1 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.5.6.1
+
+eth1VLAN6Priority OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN6 priority"
+ ::= { eth1VLAN6 2 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.5.6.2
+
+eth1VLAN6Address OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN6 IP address"
+ ::= { eth1VLAN6 3 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.5.6.3
+
+eth1VLAN6SubnetMask OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN6 subnet mask"
+ ::= { eth1VLAN6 4 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.5.6.4
+
+eth1VLAN6Router OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN6 router"
+ ::= { eth1VLAN6 5 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.5.6.5
+
+eth1MAC OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 MAC"
+ ::= { ethernet1 6 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.6
+
+eth1IPv6Mode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Controls IPv6 operation for this Ethernet interface."
+ ::= { eth1IPv6 1 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.7.1
+
+eth1IPv6StaticAddress OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "he static IPv6 address to use for this interface when in
+ operating in STATIC mode."
+ ::= { eth1IPv6Static 1 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.7.2.1
+
+eth1IPv6StaticRouter OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The IPv6 router to engage as the default router when this
+ interface operates in STATIC mode."
+ ::= { eth1IPv6Static 2 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.7.2.1
+
+eth1IPv6AutoAddress1 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "One of the automatically-acquired IPv6 addresses."
+ ::= { eth1IPv6Auto 1 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.7.3.1
+
+eth1IPv6AutoAddress2 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "One of the automatically-acquired IPv6 addresses."
+ ::= { eth1IPv6Auto 2 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.7.3.2
+
+eth1IPv6AutoAddress3 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "One of the automatically-acquired IPv6 addresses."
+ ::= { eth1IPv6Auto 3 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.7.3.3
+
+eth1IPv6AutoAddress4 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "One of the automatically-acquired IPv6 addresses."
+ ::= { eth1IPv6Auto 4 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.7.3.4
+
+eth1IPv6LinkLocalAddress OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The link local IPv6 address for this interface. This is
+ present when the IPv6 mode is not OFF."
+ ::= { eth1IPv6 4 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.7.4
+
+
+eth2Mode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Mode of the Ethernet2 interface: STATIC,DHCP,VLAN"
+ ::= { ethernet2 1 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.1
+
+eth2Address OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 IP address"
+ ::= { ethernet2 2 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.2
+
+eth2SubnetMask OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 subnet mask"
+ ::= { ethernet2 3 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.3
+
+eth2Router OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 router"
+ ::= { ethernet2 4 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.4
+
+
+-- Ethernet2 VLAN1
+
+eth2VLAN1ID OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN1 ID"
+ ::= { eth2VLAN1 1 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.5.1.1
+
+eth2VLAN1Priority OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN1 priority"
+ ::= { eth2VLAN1 2 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.5.1.2
+
+eth2VLAN1Address OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN1 IP address"
+ ::= { eth2VLAN1 3 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.5.1.3
+
+eth2VLAN1SubnetMask OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN1 subnet mask"
+ ::= { eth2VLAN1 4 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.5.1.4
+
+eth2VLAN1Router OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN1 router"
+ ::= { eth2VLAN1 5 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.5.1.5
+
+-- Ethernet2 VLAN2
+
+eth2VLAN2ID OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN2 ID"
+ ::= { eth2VLAN2 1 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.5.2.1
+
+eth2VLAN2Priority OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN2 priority"
+ ::= { eth2VLAN2 2 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.5.2.2
+
+eth2VLAN2Address OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN2 IP address"
+ ::= { eth2VLAN2 3 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.5.2.3
+
+eth2VLAN2SubnetMask OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN2 subnet mask"
+ ::= { eth2VLAN2 4 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.5.2.4
+
+eth2VLAN2Router OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN2 router"
+ ::= { eth2VLAN2 5 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.5.2.5
+
+-- Ethernet2 VLAN3
+
+eth2VLAN3ID OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN3 ID"
+ ::= { eth2VLAN3 1 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.5.3.1
+
+eth2VLAN3Priority OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN3 priority"
+ ::= { eth2VLAN3 2 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.5.3.2
+
+eth2VLAN3Address OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN3 IP address"
+ ::= { eth2VLAN3 3 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.5.3.3
+
+eth2VLAN3SubnetMask OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN3 subnet mask"
+ ::= { eth2VLAN3 4 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.5.3.4
+
+eth2VLAN3Router OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN3 router"
+ ::= { eth2VLAN3 5 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.5.3.5
+
+-- Ethernet2 VLAN4
+
+eth2VLAN4ID OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN4 ID"
+ ::= { eth2VLAN4 1 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.5.4.1
+
+eth2VLAN4Priority OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN4 priority"
+ ::= { eth2VLAN4 2 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.5.4.2
+
+eth2VLAN4Address OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN4 IP address"
+ ::= { eth2VLAN4 3 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.5.4.3
+
+eth2VLAN4SubnetMask OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN4 subnet mask"
+ ::= { eth2VLAN4 4 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.5.4.4
+
+eth2VLAN4Router OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN4 router"
+ ::= { eth2VLAN4 5 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.5.4.5
+
+-- Ethernet2 VLAN5
+
+eth2VLAN5ID OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN5 ID"
+ ::= { eth2VLAN5 1 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.5.5.1
+
+eth2VLAN5Priority OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN5 priority"
+ ::= { eth2VLAN5 2 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.5.5.2
+
+eth2VLAN5Address OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN5 IP address"
+ ::= { eth2VLAN5 3 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.5.5.3
+
+eth2VLAN5SubnetMask OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN5 subnet mask"
+ ::= { eth2VLAN5 4 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.5.5.4
+
+eth2VLAN5Router OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN5 router"
+ ::= { eth2VLAN5 5 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.5.5.5
+
+-- Ethernet2 VLAN6
+
+eth2VLAN6ID OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN6 ID"
+ ::= { eth2VLAN6 1 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.5.6.1
+
+eth2VLAN6Priority OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN6 priority"
+ ::= { eth2VLAN6 2 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.5.6.2
+
+eth2VLAN6Address OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN6 IP address"
+ ::= { eth2VLAN6 3 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.5.6.3
+
+eth2VLAN6SubnetMask OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN6 subnet mask"
+ ::= { eth2VLAN6 4 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.5.6.4
+
+eth2VLAN6Router OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN6 router"
+ ::= { eth2VLAN6 5 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.5.6.5
+
+eth2MAC OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 MAC"
+ ::= { ethernet2 6 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.6
+
+eth2IPv6Mode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Controls IPv6 operation for this Ethernet interface."
+ ::= { eth2IPv6 1 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.7.1
+
+eth2IPv6StaticAddress OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "he static IPv6 address to use for this interface when in
+ operating in STATIC mode."
+ ::= { eth2IPv6Static 1 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.7.2.1
+
+eth2IPv6StaticRouter OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The IPv6 router to engage as the default router when this
+ interface operates in STATIC mode."
+ ::= { eth2IPv6Static 2 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.7.2.1
+
+eth2IPv6AutoAddress1 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "One of the automatically-acquired IPv6 addresses."
+ ::= { eth2IPv6Auto 1 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.7.3.1
+
+eth2IPv6AutoAddress2 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "One of the automatically-acquired IPv6 addresses."
+ ::= { eth2IPv6Auto 2 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.7.3.2
+
+eth2IPv6AutoAddress3 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "One of the automatically-acquired IPv6 addresses."
+ ::= { eth2IPv6Auto 3 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.7.3.3
+
+eth2IPv6AutoAddress4 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "One of the automatically-acquired IPv6 addresses."
+ ::= { eth2IPv6Auto 4 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.7.3.4
+
+eth2IPv6LinkLocalAddress OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The link local IPv6 address for this interface. This is
+ present when the IPv6 mode is not OFF."
+ ::= { eth2IPv6 4 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.7.4
+
+
+defaultRouter OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The default router/gateway"
+ ::= { network 2 }
+ --1.3.6.1.4.1.3052.14.2.4.2
+
+-- DNS
+
+dnsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF DNSConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "DNS server address table"
+ ::= { network 3 }
+ --1.3.6.1.4.1.3052.14.2.4.3
+
+dnsEntry OBJECT-TYPE
+ SYNTAX DNSConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "DNS server address entry"
+ INDEX { dnsIndex }
+ ::= { dnsTable 1 }
+ --1.3.6.1.4.1.3052.14.2.4.3.1
+
+dnsIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..2)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for DNS server address"
+ ::= { dnsEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.4.3.1.1
+
+dnsAddress OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "DNS server address"
+ ::= { dnsEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.4.3.1.2
+
+hostname OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The hostname of the unit"
+ ::= { network 4 }
+ --1.3.6.1.4.1.3052.14.2.4.4
+
+hostTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF HostConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Static host table"
+ ::= { network 5 }
+ --1.3.6.1.4.1.3052.14.2.4.5
+
+hostEntry OBJECT-TYPE
+ SYNTAX HostConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Static host entry"
+ INDEX { hostIndex }
+ ::= { hostTable 1 }
+ --1.3.6.1.4.1.3052.14.2.4.5.1
+
+hostIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..2)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for static host"
+ ::= { hostEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.4.5.1.1
+
+hostDeclaration OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Static host declaration string (i.e. 'address hostname')"
+ ::= { hostEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.4.5.1.2
+
+-- Network Command Processor
+
+ncpDuplex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "For network command processor: 1=Input characters are echoed; 0=no echo."
+ ::= { network 6 }
+ --1.3.6.1.4.1.3052.14.2.4.6
+
+ncpTimeout OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Network command processor inactivity timeout"
+ ::= { network 7 }
+ --1.3.6.1.4.1.3052.14.2.4.7
+
+-- SNMP
+
+snmpAgentEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF for snmp agent"
+ ::= { snmp 1 }
+ --1.3.6.1.4.1.3052.14.2.4.8.1
+
+snmpNotificationCaptureEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF unit receives and stores SNMP traps/informs"
+ ::= { snmp 5 }
+ --1.3.6.1.4.1.3052.14.2.4.8.5
+
+snmpNotificationCaptureFile OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "File to which unit stores received SNMP traps/informs"
+ ::= { snmp 6 }
+ --1.3.6.1.4.1.3052.14.2.4.8.6
+
+snmpNtfnAttempts OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Maximum of times the unit attempts to send a notification
+ (trap/inform) in 1 cycle"
+ ::= { snmpNotificationTx 1 }
+ --1.3.6.1.4.1.3052.14.2.4.8.7.1
+
+snmpNtfnTimeout OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number of seconds between retries of sending a notification"
+ ::= { snmpNotificationTx 2 }
+ --1.3.6.1.4.1.3052.14.2.4.8.7.2
+
+snmpNtfnCycles OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number of times the unit attempts a group of attempts to send
+ a notification (a cycle)"
+ ::= { snmpNotificationTx 3 }
+ --1.3.6.1.4.1.3052.14.2.4.8.7.3
+
+snmpNtfnSnooze OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Minutes between cycles"
+ ::= { snmpNotificationTx 4 }
+ --1.3.6.1.4.1.3052.14.2.4.8.7.4
+
+
+-- SNMP Poll
+
+snmpPMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Mode of poll operation: OFF, POLL ONLY (just make the results
+ available to view), or POLL BUFFER (store the results)."
+ ::= { snmpPoll 1 }
+ --1.3.6.1.4.1.3052.14.2.4.8.9.1
+
+snmpPBufferFile OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "CRDB file in which data is stored."
+ ::= { snmpPoll 2 }
+ --1.3.6.1.4.1.3052.14.2.4.8.9.2
+
+snmpPBufferAllPeriod OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Period (in seconds) that, if non-zero, all results are buffered
+ in the CRDB regardless of the threshold."
+ ::= { snmpPoll 3 }
+ --1.3.6.1.4.1.3052.14.2.4.8.9.3
+
+snmpPRequestTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SNMPPollRequestConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of SNMP Poll requests."
+ ::= { snmpPoll 4 }
+ --1.3.6.1.4.1.3052.14.2.4.8.9.4
+
+snmpPRequestEntry OBJECT-TYPE
+ SYNTAX SNMPPollRequestConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table pf SNMP Poll requests."
+ INDEX { snmpPRequestIndex }
+ ::= { snmpPRequestTable 1 }
+ --1.3.6.1.4.1.3052.14.2.4.8.9.4.1
+
+snmpPRequestIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..64)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of SNMP Poll requests."
+ ::= { snmpPRequestEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.4.8.9.4.1.1
+
+snmpPRequestDescription OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A description for this single telemetry request; no functional effect."
+ ::= { snmpPRequestEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.4.8.9.4.1.2
+
+snmpPRequestAgent OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "SNMP Agent IP address or hostname for this single telemetry request."
+ ::= { snmpPRequestEntry 3 }
+ --1.3.6.1.4.1.3052.14.2.4.8.9.4.1.3
+
+snmpPRequestReadcom OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "SNMP read community for this single telemetry request."
+ ::= { snmpPRequestEntry 4 }
+ --1.3.6.1.4.1.3052.14.2.4.8.9.4.1.4
+
+snmpPRequestOID OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "SNMP object identifier for this single telemetry request."
+ ::= { snmpPRequestEntry 5 }
+ --1.3.6.1.4.1.3052.14.2.4.8.9.4.1.5
+
+snmpPRequestPeriod OBJECT-TYPE
+ SYNTAX Integer32 (1..255)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "How many seconds between periodic SNMP polls of this
+ single telemetry request."
+ ::= { snmpPRequestEntry 6 }
+ --1.3.6.1.4.1.3052.14.2.4.8.9.4.1.6
+
+snmpPRequestID OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A textual field that is part of the record containing
+ the telemetry result."
+ ::= { snmpPRequestEntry 7 }
+ --1.3.6.1.4.1.3052.14.2.4.8.9.4.1.7
+
+snmpPRequestThreshold OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Controls when new data is stored upon a successful
+ telemetry request."
+ ::= { snmpPRequestEntry 8 }
+ --1.3.6.1.4.1.3052.14.2.4.8.9.4.1.8
+
+snmpPRequestResultStatus OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Status of the last attempt for this telemetry request."
+ ::= { snmpPRequestEntry 10 }
+ --1.3.6.1.4.1.3052.14.2.4.8.9.4.1.10
+
+snmpPRequestResultValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The telemetry value if the last request was successful."
+ ::= { snmpPRequestEntry 11 }
+ --1.3.6.1.4.1.3052.14.2.4.8.9.4.1.11
+
+snmpPRequestResultTime OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The timestamp of the last telemetry request."
+ ::= { snmpPRequestEntry 12 }
+ --1.3.6.1.4.1.3052.14.2.4.8.9.4.1.12
+
+snmpPRequestResultType OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The type of the telemetry as reported by the agent."
+ ::= { snmpPRequestEntry 13 }
+ --1.3.6.1.4.1.3052.14.2.4.8.9.4.1.13
+
+
+-- FTP
+
+ftpPushEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable FTP push for REGULAR (protocol: FTP) or SECURE (protocol:
+ SFTP) operation, or disable it (OFF)"
+ ::= { ftpPush 1 }
+ --1.3.6.1.4.1.3052.14.2.4.9.1
+
+ftpPushServer OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "FTP server to which data should be pushed"
+ ::= { ftpPush 2 }
+ --1.3.6.1.4.1.3052.14.2.4.9.2
+
+ftpPushAccount OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "FTP push account"
+ ::= { ftpPush 5 }
+ --1.3.6.1.4.1.3052.14.2.4.9.5
+
+ftpPushDirectory OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "FTP push directory"
+ ::= { ftpPush 6 }
+ --1.3.6.1.4.1.3052.14.2.4.9.6
+
+ftpPushperiod OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Minutes between pushes"
+ ::= { ftpPush 7 }
+ --1.3.6.1.4.1.3052.14.2.4.9.7
+
+ftpPushPushFileTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF FTPPushPushFileConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of files to push"
+ ::= { ftpPush 8 }
+ --1.3.6.1.4.1.3052.14.2.4.9.8
+
+ftpPushPushFileEntry OBJECT-TYPE
+ SYNTAX FTPPushPushFileConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of files to push"
+ INDEX { ftpPushPushFileIndex }
+ ::= { ftpPushPushFileTable 1 }
+ --1.3.6.1.4.1.3052.14.2.4.9.8.1
+
+ftpPushPushFileIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..16)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of files to push"
+ ::= { ftpPushPushFileEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.4.9.8.1.1
+
+ftpPushPushFile OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF push this local FILEx"
+ ::= { ftpPushPushFileEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.4.9.8.1.2
+
+ftpPushPushAudit OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF push the audit log"
+ ::= { ftpPush 9 }
+ --1.3.6.1.4.1.3052.14.2.4.9.9
+
+ftpPushPushAlarms OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF push the alarms/events file"
+ ::= { ftpPush 10 }
+ --1.3.6.1.4.1.3052.14.2.4.9.10
+
+ftpPushRemoteFileTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF FTPPushRemoteFileConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of remote names of files to push"
+ ::= { ftpPush 11 }
+ --1.3.6.1.4.1.3052.14.2.4.9.11
+
+ftpPushRemoteFileEntry OBJECT-TYPE
+ SYNTAX FTPPushRemoteFileConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of remote names of files to push"
+ INDEX { ftpPushRemoteFileIndex }
+ ::= { ftpPushRemoteFileTable 1 }
+ --1.3.6.1.4.1.3052.14.2.4.9.11.1
+
+ftpPushRemoteFileIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..16)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of remote names of files to push"
+ ::= { ftpPushRemoteFileEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.4.9.11.1
+
+ftpPushRemoteFileName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "remote name of pushed FILEx (name on server)"
+ ::= { ftpPushRemoteFileEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.4.9.11.2
+
+ftpPushRemoteAlarmName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Filename on server for alarms"
+ ::= { ftpPush 12 }
+ --1.3.6.1.4.1.3052.14.2.4.9.12
+
+ftpPushPassive OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF use ftp passive mode"
+ ::= { ftpPush 13 }
+ --1.3.6.1.4.1.3052.14.2.4.9.13
+
+ftpPushIncludeDate OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF include the date in the name of the pushed file"
+ ::= { ftpPush 14 }
+ --1.3.6.1.4.1.3052.14.2.4.9.14
+
+ftpPushIncludeTime OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF include the time in the name of the pushed file"
+ ::= { ftpPush 15 }
+ --1.3.6.1.4.1.3052.14.2.4.9.15
+
+ftpPushIncludeSeq OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF include a sequence number in the name of the pushed file"
+ ::= { ftpPush 16 }
+ --1.3.6.1.4.1.3052.14.2.4.9.16
+
+ftpPushPermissions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Unix permissions to apply to pushed files (octal notation)."
+ ::= { ftpPush 17 }
+ --1.3.6.1.4.1.3052.14.2.4.9.17
+
+
+pppDialEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF PPP dialout enabled"
+ ::= { pppDial 1 }
+ --1.3.6.1.4.1.3052.14.2.4.10.1.1
+
+pppDialNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "phone number to dial"
+ ::= { pppDial 2 }
+ --1.3.6.1.4.1.3052.14.2.4.10.1.2
+
+pppDialIdleTimeout OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Seconds of inactivity after which the unit disconnects"
+ ::= { pppDial 5 }
+ --1.3.6.1.4.1.3052.14.2.4.10.1.5
+
+pppDialRetries OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number of dialing retries for PPP"
+ ::= { pppDial 6 }
+ --1.3.6.1.4.1.3052.14.2.4.10.1.6
+
+pppDialCDTimeout OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number of seconds to wait after dialing for CD before
+ giving up"
+ ::= { pppDial 7 }
+ --1.3.6.1.4.1.3052.14.2.4.10.1.7
+
+pppDialLoginTimeout OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Seconds to wait to negotiate PPP after connecting"
+ ::= { pppDial 8 }
+ --1.3.6.1.4.1.3052.14.2.4.10.1.8
+
+pppDialMdmInit OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Modem init string to use when dialing PPP"
+ ::= { pppDial 9 }
+ --1.3.6.1.4.1.3052.14.2.4.10.1.9
+
+pppDialSuggestIP OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "IP address to suggest as the unit's end (local end) of the
+ PPP link"
+ ::= { pppDial 10 }
+ --1.3.6.1.4.1.3052.14.2.4.10.1.10
+
+pppDialPlainLogin OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF look for login/password prompt before negotiating
+ PPP"
+ ::= { pppDial 11 }
+ --1.3.6.1.4.1.3052.14.2.4.10.1.11
+
+pppHostEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF Unit accepts PPP negotiation"
+ ::= { pppHost 1 }
+ --1.3.6.1.4.1.3052.14.2.4.10.2.1
+
+pppHostIdleTimeout OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Seconds of inactivity after which PPP-hosted link will
+ terminate"
+ ::= { pppHost 2 }
+ --1.3.6.1.4.1.3052.14.2.4.10.2.2
+
+pppHostLocalIP OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Local IP address to negotiate"
+ ::= { pppHost 3 }
+ --1.3.6.1.4.1.3052.14.2.4.10.2.3
+
+pppHostRemoteIP OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Remote IP address to hand out to PPP peer"
+ ::= { pppHost 4 }
+ --1.3.6.1.4.1.3052.14.2.4.10.2.4
+
+-- Routing
+
+pppRoutingEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF unit routes IP traffic from PPP/Wireless to Ethernet"
+ ::= { routing 1 }
+ --1.3.6.1.4.1.3052.14.2.4.11.1
+
+ethRoutingEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF unit routes IP traffic from Ethernet to PPP/Wireless"
+ ::= { routing 2 }
+ --1.3.6.1.4.1.3052.14.2.4.11.2
+
+ethRoutingNATEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF unit applies NAT on routed IP frames egressing the
+ unit on its PPP interface"
+ ::= { routing 3 }
+ --1.3.6.1.4.1.3052.14.2.4.11.3
+
+routingInterface OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "When Ethernet routing is enabled (routing.1), this is the
+ Ethernet interface to which IP frames received on PPP are
+ routed"
+ ::= { routing 4 }
+ --1.3.6.1.4.1.3052.14.2.4.11.4
+
+eth2WanRoutingEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Make ETH2 operate as a WAN port to route outbound traffic
+ arriving on ETH1."
+ ::= { routing 5 }
+ --1.3.6.1.4.1.3052.14.2.4.11.5
+
+-- IP Restrictions
+
+ipRestrictionTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IPRestrictionConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of IP restrictions"
+ ::= { ipRestriction 1 }
+ --1.3.6.1.4.1.3052.14.2.4.12.1.1
+
+ipRestrictionEntry OBJECT-TYPE
+ SYNTAX IPRestrictionConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of IP restrictions"
+ INDEX { ipRestrictionIndex }
+ ::= { ipRestrictionTable 1 }
+ --1.3.6.1.4.1.3052.14.2.4.12.1.1
+
+ipRestrictionIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..8)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of IP restrictions"
+ ::= { ipRestrictionEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.4.12.1.1.1.1
+
+ipRestrictionEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable this IP restriction"
+ ::= { ipRestrictionEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.4.12.1.1.1.2
+
+ipRestrictionMask OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "IP restriction mask"
+ ::= { ipRestrictionEntry 3 }
+ --1.3.6.1.4.1.3052.14.2.4.12.1.1.1.3
+
+
+-- RTS
+
+
+rtsFileTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF RTSFileConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of RTS files"
+ ::= { rts 1 }
+ --1.3.6.1.4.1.3052.14.2.4.13.1
+
+rtsFileEntry OBJECT-TYPE
+ SYNTAX RTSFileConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of RTS files"
+ INDEX { rtsFileIndex }
+ ::= { rtsFileTable 1 }
+ --1.3.6.1.4.1.3052.14.2.4.13.1
+
+rtsFileIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..16)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of RTS files"
+ ::= { rtsFileEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.4.13.1.1.1
+
+rtsFileMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "RTS mode (OFF,LISTEN,PUSH) for FILEx"
+ ::= { rtsFileEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.4.13.1.1.2
+
+rtsFileShowAnswer OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Show answer string upon RTS connect for FILEx"
+ ::= { rtsFileEntry 3 }
+ --1.3.6.1.4.1.3052.14.2.4.13.1.1.3
+
+rtsFileReqXON OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF require XON to start flow for FILEx"
+ ::= { rtsFileEntry 4 }
+ --1.3.6.1.4.1.3052.14.2.4.13.1.1.4
+
+rtsFileTimeout OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Idle connection close timer (0 means no timeout) for FILEx"
+ ::= { rtsFileEntry 5 }
+ --1.3.6.1.4.1.3052.14.2.4.13.1.1.5
+
+rtsFileEmptyClose OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF close the socket when FILEx is empty"
+ ::= { rtsFileEntry 6 }
+ --1.3.6.1.4.1.3052.14.2.4.13.1.1.6
+
+rtsFilePushHost OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Host to which FILEx should be pushed via RTS"
+ ::= { rtsFileEntry 7 }
+ --1.3.6.1.4.1.3052.14.2.4.13.1.1.7
+
+rtsFilePushPort OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "TCP port to which FILEx should be pushed via RTS"
+ ::= { rtsFileEntry 8 }
+ --1.3.6.1.4.1.3052.14.2.4.13.1.1.8
+
+rtsFilePushRetryTimer OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Retry timer (seconds) for retrying failed RTS push connect
+ attempts"
+ ::= { rtsFileEntry 9 }
+ --1.3.6.1.4.1.3052.14.2.4.13.1.1.9
+
+-- RTS Alarms
+
+rtsAlarmsMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "RTS mode (OFF,LISTEN,PUSH) for alarms file"
+ ::= { rtsAlarms 1 }
+ --1.3.6.1.4.1.3052.14.2.4.13.2.1
+
+rtsAlarmsShowAnswer OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Show answer string upon RTS connect for alarms file"
+ ::= { rtsAlarms 2 }
+ --1.3.6.1.4.1.3052.14.2.4.13.2.2
+
+rtsAlarmsReqXON OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF require XON to start flow for alarms file"
+ ::= { rtsAlarms 3 }
+ --1.3.6.1.4.1.3052.14.2.4.13.2.3
+
+rtsAlarmsTimeout OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Idle connection close timer (0 means no timeout) for alarms
+ file"
+ ::= { rtsAlarms 4 }
+ --1.3.6.1.4.1.3052.14.2.4.13.2.4
+
+rtsAlarmsEmptyClose OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF close the socket when this file is empty for alarms
+ file"
+ ::= { rtsAlarms 5 }
+ --1.3.6.1.4.1.3052.14.2.4.13.2.5
+
+rtsAlarmsPushHost OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Host to which alarms file should be pushed via RTS"
+ ::= { rtsAlarms 6 }
+ --1.3.6.1.4.1.3052.14.2.4.13.2.6
+
+rtsAlarmsPushPort OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "TCP port to which alarms file should be pushed via RTS"
+ ::= { rtsAlarms 7 }
+ --1.3.6.1.4.1.3052.14.2.4.13.2.7
+
+rtsAlarmsPushRetryTimer OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Retry timer (seconds) for retrying failed RTS push connect
+ attempts"
+ ::= { rtsAlarms 8 }
+ --1.3.6.1.4.1.3052.14.2.4.13.2.8
+
+-- Traps
+
+trapIncludeDateTime OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF include date and time in stock trap message"
+ ::= { trapInclude 1 }
+ --1.3.6.1.4.1.3052.14.2.4.14.1.1
+
+trapIncludeSiteName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF include site name in stock trap message"
+ ::= { trapInclude 2 }
+ --1.3.6.1.4.1.3052.14.2.4.14.1.2
+
+trapIncludeSensorID OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF include sensor ID in stock trap message"
+ ::= { trapInclude 3 }
+ --1.3.6.1.4.1.3052.14.2.4.14.1.3
+
+trapIncludeUDName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF include user defined name in stock trap message"
+ ::= { trapInclude 4 }
+ --1.3.6.1.4.1.3052.14.2.4.14.1.4
+
+trapIncludeUDState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF include user defined state in stock trap message"
+ ::= { trapInclude 5 }
+ --1.3.6.1.4.1.3052.14.2.4.14.1.5
+
+trapIncludeSourceAddress OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF include source IP address in stock trap message"
+ ::= { trapInclude 6 }
+ --1.3.6.1.4.1.3052.14.2.4.14.1.6
+
+trapAuthFailEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable trap sent upon SNMP authentication failure"
+ ::= { trap 2 }
+ --1.3.6.1.4.1.3052.14.2.4.14.2
+
+-- Route testing
+
+routeTestEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable route testing"
+ ::= { routeTest 1 }
+ --1.3.6.1.4.1.3052.14.2.4.15.1
+
+
+routeTestPeriod OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The period which a route is considered valid"
+ ::= { routeTest 2 }
+ --1.3.6.1.4.1.3052.14.2.4.15.2
+
+routeTestAddressTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF RouteTestConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of route testing addresses"
+ ::= { routeTest 3 }
+ --1.3.6.1.4.1.3052.14.2.4.15.3
+
+routeTestAddressEntry OBJECT-TYPE
+ SYNTAX RouteTestConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of RTS files"
+ INDEX { routeTestAddressIndex }
+ ::= { routeTestAddressTable 1 }
+ --1.3.6.1.4.1.3052.14.2.4.15.3.1
+
+routeTestAddressIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..3)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of RTS files"
+ ::= { routeTestAddressEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.4.15.3.1.1
+
+routeTestAddress OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Address to ping to see if the route to it is valid"
+ ::= { routeTestAddressEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.4.15.3.1.2
+
+
+-- Wireless
+
+
+wirelessMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Wireless mode (OFF,PERMANENT-EDGE)"
+ ::= { wireless 1 }
+ --1.3.6.1.4.1.3052.14.2.4.16.1
+
+wirelessAPN OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Wireless access point name"
+ ::= { wireless 2 }
+ --1.3.6.1.4.1.3052.14.2.4.16.2
+
+wirelessIdleTimeout OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Wireless idle timeout"
+ ::= { wireless 3 }
+ --1.3.6.1.4.1.3052.14.2.4.16.3
+
+wirelessDRE OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Default route enable for wireless network interface.
+ When this is ON, the wireless link, if up, becomes
+ the default route, overriding the default route setting
+ (defaultRouter object). When OFF, the default route
+ setting controls the default route and the wireless link
+ does not become the default route."
+ ::= { wireless 9 }
+ --1.3.6.1.4.1.3052.14.2.4.16.9
+
+wirelessPPPUsername OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Username for PPP-based wireless modem connections."
+ ::= { wireless 10 }
+ --1.3.6.1.4.1.3052.14.2.4.16.10
+
+wirelessFirewall OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable wireless modem firewall."
+ ::= { wireless 11 }
+ --1.3.6.1.4.1.3052.14.2.4.16.11
+
+wirelessKeepaliveThreshold OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Minutes of no RX activity before sending keep-alive."
+ ::= { wireless 12 }
+ --1.3.6.1.4.1.3052.14.2.4.16.12
+
+wirelessPPPDebug OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable wireless modem PPP debug."
+ ::= { wireless 13 }
+ --1.3.6.1.4.1.3052.14.2.4.16.13
+
+wirelessConnEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable wireless modem connectivity check."
+ ::= { wirelessConnectivity 1 }
+ --1.3.6.1.4.1.3052.14.2.4.16.20.1
+
+wirelessConnCheckInterval OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Wireless connectivity check interval in minutes."
+ ::= { wirelessConnectivity 2 }
+ --1.3.6.1.4.1.3052.14.2.4.16.20.2
+
+wirelessConnFailThreshold OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Wireless connectivity fail threshold."
+ ::= { wirelessConnectivity 3 }
+ --1.3.6.1.4.1.3052.14.2.4.16.20.3
+
+wirelessConnIP1 OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Wireless connectivity check IP address 1."
+ ::= { wirelessConnectivity 10 }
+ --1.3.6.1.4.1.3052.14.2.4.16.20.10
+
+wirelessConnIP2 OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Wireless connectivity check IP address 2."
+ ::= { wirelessConnectivity 11 }
+ --1.3.6.1.4.1.3052.14.2.4.16.20.11
+
+
+-- Email
+
+
+emailServer OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "SMTP server to which the unit sends email"
+ ::= { email 1 }
+ --1.3.6.1.4.1.3052.14.2.4.17.1
+
+emailDomain OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Domain to use in recipient address"
+ ::= { email 2 }
+ --1.3.6.1.4.1.3052.14.2.4.17.2
+
+emailAuthEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable SMTP authentication"
+ ::= { email 3 }
+ --1.3.6.1.4.1.3052.14.2.4.17.3
+
+-- Advanced network config
+
+arpFilter OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ARP filter code"
+ ::= { netAdvanced 1 }
+ --1.3.6.1.4.1.3052.14.2.4.18.1
+
+
+-- Web interface
+
+webEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF for the web interface"
+ ::= { web 1 }
+ --1.3.6.1.4.1.3052.14.2.4.19.1
+
+webPort OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "TCP port on which web interface listens"
+ ::= { web 2 }
+ --1.3.6.1.4.1.3052.14.2.4.19.2
+
+webTimeout OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Web interface session timeout (seconds)"
+ ::= { web 3 }
+ --1.3.6.1.4.1.3052.14.2.4.19.3
+
+
+
+-- IPv6
+
+ipv6DefaultRouter OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The IPv6 default router in use."
+ ::= { ipv6 1 }
+ --1.3.6.1.4.1.3052.14.2.4.21.1
+
+
+
+-- CPE table
+
+cpeTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CPEConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of CPEs"
+ ::= { cpe 1 }
+ --1.3.6.1.4.1.3052.14.2.4.22.1
+
+cpeEntry OBJECT-TYPE
+ SYNTAX CPEConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of CPEs"
+ INDEX { cpeIndex }
+ ::= { cpeTable 1 }
+ --1.3.6.1.4.1.3052.14.2.4.22.1.1
+
+cpeIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..16)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of CPEs"
+ ::= { cpeEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.4.22.1.1.1
+
+cpeHost OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "CPE host (IP address or DNS name)"
+ ::= { cpeEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.4.22.1.1.2
+
+cpeName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "CPE name, informational only"
+ ::= { cpeEntry 3 }
+ --1.3.6.1.4.1.3052.14.2.4.22.1.1.3
+
+cpeDescription OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "CPE description, informational only"
+ ::= { cpeEntry 4 }
+ --1.3.6.1.4.1.3052.14.2.4.22.1.1.4
+
+cpeKeepalive OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number of seconds between each successful ping request."
+ ::= { cpeEntry 5 }
+ --1.3.6.1.4.1.3052.14.2.4.22.1.1.5
+
+cpeThreshold OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number of unsuccessful pings that triggers the CPE event."
+ ::= { cpeEntry 6 }
+ --1.3.6.1.4.1.3052.14.2.4.22.1.1.6
+
+cpeEventReminderInterval OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "CPE event reminder interval (minutes)."
+ ::= { cpeEntry 7 }
+ --1.3.6.1.4.1.3052.14.2.4.22.1.1.7
+
+cpeKeepaliveTicks OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "CPE ping period in 16ths of a second (nonzero overrides keepalive)."
+ ::= { cpeEntry 20 }
+ --1.3.6.1.4.1.3052.14.2.4.22.1.1.20
+
+cpePingSize OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number of bytes in CPE ping payload"
+ ::= { cpeEntry 21 }
+ --1.3.6.1.4.1.3052.14.2.4.22.1.11
+
+cpeInfoReset OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Set any number to reset CPE ping stats."
+ ::= { cpeEntry 30 }
+ --1.3.6.1.4.1.3052.14.2.4.22.1.1.30
+
+cpeInfoNumReq OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of requests transmitted."
+ ::= { cpeEntry 31 }
+ --1.3.6.1.4.1.3052.14.2.4.22.1.1.31
+
+cpeInfoNumGoodResp OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of non-corrupt responses."
+ ::= { cpeEntry 32 }
+ --1.3.6.1.4.1.3052.14.2.4.22.1.1.32
+
+cpeInfoNumBadResp OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of corrupt responses."
+ ::= { cpeEntry 33 }
+ --1.3.6.1.4.1.3052.14.2.4.22.1.1.33
+
+cpeInfoNumLostResp OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of requests with no response."
+ ::= { cpeEntry 34 }
+ --1.3.6.1.4.1.3052.14.2.4.22.1.1.34
+
+cpeInfoPercentLoss OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Percent loss (missing responses / total requests)."
+ ::= { cpeEntry 35 }
+ --1.3.6.1.4.1.3052.14.2.4.22.1.1.35
+
+cpeInfoPercentBad OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Percent corrupt (corrupt responses / total requests)."
+ ::= { cpeEntry 36 }
+ --1.3.6.1.4.1.3052.14.2.4.22.1.1.36
+
+--***************************************************************************************
+--Modem Section 2.5
+--***************************************************************************************
+
+
+
+
+
+modemFormat OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Modem data format (8N1,7E1,7O1,7N1)"
+ ::= { modem 1 }
+ --1.3.6.1.4.1.3052.14.2.5.1
+
+modemInitString OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Init string for modem"
+ ::= { modem 2 }
+ --1.3.6.1.4.1.3052.14.2.5.2
+
+
+modemCallAttempts OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Max mumber of times the modem should try to call out until
+ successful connect"
+ ::= { modem 4 }
+ --1.3.6.1.4.1.3052.14.2.5.4
+
+modemCallDelay OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Minimum delay (seconds) between callouts"
+ ::= { modem 5 }
+ --1.3.6.1.4.1.3052.14.2.5.6
+
+
+modemCmdTimout OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number of minutes after which an idle command session via
+ modem is terminated"
+ ::= { modem 6 }
+ --1.3.6.1.4.1.3052.14.2.5.6
+
+modemGoto OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "When a user connects, where that user is routed (command
+ session, passthrough to port 1, passthrough to port 2, etc.)"
+ ::= { modem 7 }
+ --1.3.6.1.4.1.3052.14.2.5.7
+
+
+modemCLIDEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF Calling Line Identification security"
+ ::= { modemClid 1 }
+ --1.3.6.1.4.1.3052.14.2.5.8.1
+
+
+modemCLIDNumberTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ModemCLIDNumberConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of authorized callers identified by phone number"
+ ::= { modemClid 2 }
+ --1.3.6.1.4.1.3052.14.2.5.8.2
+
+modemCLIDNumberEntry OBJECT-TYPE
+ SYNTAX ModemCLIDNumberConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of CLID numbers"
+ INDEX { modemCLIDNumberIndex }
+ ::= { modemCLIDNumberTable 1 }
+ --1.3.6.1.4.1.3052.14.2.5.8.2.1
+
+modemCLIDNumberIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..20)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of CLID numbers"
+ ::= { modemCLIDNumberEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.5.8.2.1.1
+
+modemCLIDNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "auhorized CLID number"
+ ::= { modemCLIDNumberEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.5.8.2.1.2
+
+modemTAPInitString OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Init string to use for TAP (pager) connections"
+ ::= { modem 9 }
+ --1.3.6.1.4.1.3052.14.2.5.9
+
+modemTAP8N1 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF: use 8N1 data/parity/stop for TAP connections"
+ ::= { modem 10 }
+ --1.3.6.1.4.1.3052.14.2.5.10
+
+
+--***************************************************************************************
+--Time Section 2.8
+--***************************************************************************************
+
+clock OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Text string for date and time;
+ e.g. 'SUN 01/02/98 12:34:27'. When setting
+ this object, only the date and time are
+ required; the unit will ignore a specified
+ day of week because it is calculated from
+ the date and time. When this object is included
+ in a notification as a varbind, it represents
+ the time that the triggering event occurred."
+ ::= { time 1 }
+ --1.3.6.1.4.1.3052.14.2.8.1
+
+--***************************************************************************************
+--Console Section 2.10
+--***************************************************************************************
+
+
+consoleDuplex OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF characters echoed on telnet command session"
+ ::= { console 1 }
+ --1.3.6.1.4.1.3052.14.2.10.1
+
+consoleTimeout OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Minutes of inactivity after which telnet command session is terminated"
+ ::= { console 2 }
+ --1.3.6.1.4.1.3052.14.2.10.2
+
+consoleBaud OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Console baud rate"
+ ::= { console 4 }
+ --1.3.6.1.4.1.3052.14.2.10.4
+
+consoleFormat OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Console data format (8N1,7E1,7O1,7N1,8O2)"
+ ::= { console 5 }
+ --1.3.6.1.4.1.3052.14.2.10.5
+
+consoleHsk OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Console handshaking mode"
+ ::= { console 6 }
+ --1.3.6.1.4.1.3052.14.2.10.6
+
+consoleConfirm OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF Prompt to confirm certain actions"
+ ::= { console 7 }
+ --1.3.6.1.4.1.3052.14.2.10.7
+
+--***************************************************************************************
+--Core Security Section 2.11.1
+--***************************************************************************************
+
+scShowPasswordPrompt OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF show password prompt upon login"
+ ::= { secCore 1 }
+ --1.3.6.1.4.1.3052.14.2.11.1.1
+
+scConsoleLoginRequired OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF login required upon connecting via console"
+ ::= { secCore 2 }
+ --1.3.6.1.4.1.3052.14.2.11.1.2
+
+scModemLoginRequired OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF login required upon connecting via modem"
+ ::= { secCore 3 }
+ --1.3.6.1.4.1.3052.14.2.11.1.3
+
+scTelnetLoginRequired OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF login required upon connecting via Telnet"
+ ::= { secCore 4 }
+ --1.3.6.1.4.1.3052.14.2.11.1.4
+
+scTelnetPTLoginRequired OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF login required upon connecting via Telnet to pass-
+ through ports (TCP ports 210x)"
+ ::= { secCore 5 }
+ --1.3.6.1.4.1.3052.14.2.11.1.5
+
+scRTSLoginRequired OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF login required upon connecting to RTS (TCP ports 220x)"
+ ::= { secCore 6 }
+ --1.3.6.1.4.1.3052.14.2.11.1.6
+
+scAuthMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Authentication mode (USERNAME/PW,PW/USERNAME,PASSWORD ONLY)"
+ ::= { secCore 7 }
+ --1.3.6.1.4.1.3052.14.2.11.1.7
+
+scRightsGroup OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The set of aliases used for the 8 available rights levels"
+ ::= { secCore 8 }
+ --1.3.6.1.4.1.3052.14.2.11.1.8
+
+
+--***************************************************************************************
+--User Security Section 2.11.2
+--***************************************************************************************
+
+
+secUserTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SecUserConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of users"
+ ::= { unitSecurity 2 }
+ --1.3.6.1.4.1.3052.14.2.11.2
+
+secUserEntry OBJECT-TYPE
+ SYNTAX SecUserConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of users"
+ INDEX { secUserIndex }
+ ::= { secUserTable 1 }
+ --1.3.6.1.4.1.3052.14.2.11.2.1
+
+secUserIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..12)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of users"
+ ::= { secUserEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.11.2.1.1
+
+secUserEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable user"
+ ::= { secUserEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.11.2.1.2
+
+secUserConnectVia OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Methods by which user is allowed to connect:
+ L=local (console)
+ T=Telnet
+ M=modem
+ F=FTP
+ R=RTS
+ S=SSH
+ "
+ ::= { secUserEntry 5 }
+ --1.3.6.1.4.1.3052.14.2.11.2.1.5
+
+secUserLoginTo OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The function presented to the user upon login (COMMAND,
+ PASSTHROUGH,MENU)"
+ ::= { secUserEntry 6 }
+ --1.3.6.1.4.1.3052.14.2.11.2.1.6
+
+secUserAccessFile OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The default access file associated with the user"
+ ::= { secUserEntry 7 }
+ --1.3.6.1.4.1.3052.14.2.11.2.1.7
+
+secUserPTEscapeTo OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The function presented to the user upon escaping pass-
+ through: currently only MENU"
+ ::= { secUserEntry 9 }
+ --1.3.6.1.4.1.3052.14.2.11.2.1.9
+
+secUserPPPType OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The kind of PPP access allowed to this user cannot connect
+ via PPP (NONE), can connect but only to the unit (LOCAL), or
+ can connect and route to Ethernet (ROUTING)"
+ ::= { secUserEntry 10 }
+ --1.3.6.1.4.1.3052.14.2.11.2.1.10
+
+secUserRights OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The rights level granted to this user"
+ ::= { secUserEntry 11 }
+ --1.3.6.1.4.1.3052.14.2.11.2.1.11
+
+secUserEventsReadAccess OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "DENY/ALLOW user to read the events/alarms file"
+ ::= { secUserEntry 13 }
+ --1.3.6.1.4.1.3052.14.2.11.2.1.13
+
+secUserAuditReadAccess OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "DENY/ALLOW user to read the audit log"
+ ::= { secUserEntry 14 }
+ --1.3.6.1.4.1.3052.14.2.11.2.1.14
+
+secUserEventsWriteAccess OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "DENY/ALLOW user to delete the events file"
+ ::= { secUserEntry 16 }
+ --1.3.6.1.4.1.3052.14.2.11.2.1.16
+
+secUserAuditWriteAccess OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "DENY/ALLOW user to write to the audit log"
+ ::= { secUserEntry 17 }
+ --1.3.6.1.4.1.3052.14.2.11.2.1.17
+
+secUserExpiration OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Expiration date/time of this user"
+ ::= { secUserEntry 18 }
+ --1.3.6.1.4.1.3052.14.2.11.2.1.18
+
+secUserCallbackNumber1 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number slot 1 the unit calls for dialback"
+ ::= { secUserEntry 19 }
+ --1.3.6.1.4.1.3052.14.2.11.2.1.19
+
+secUserCallbackNumber2 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number slot 2 the unit calls for dialback"
+ ::= { secUserEntry 20 }
+ --1.3.6.1.4.1.3052.14.2.11.2.1.20
+
+secUserCallbackNumber3 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number slot 3 the unit calls for dialback"
+ ::= { secUserEntry 21 }
+ --1.3.6.1.4.1.3052.14.2.11.2.1.21
+
+secUserChallengeTelnetMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Telnet challenge mode: when user logs in via telnet, unit
+ allows access (OFF), presents a challenge (CHALLENGE), or
+ unit sends a one-time-password (SEND PASSWORD) to a
+ destination configured by secUserChallengeTelnetSendTo"
+ ::= { secUserEntry 22 }
+ --1.3.6.1.4.1.3052.14.2.11.2.1.22
+
+secUserChallengeModemMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Modem challenge mode: when user logs in via modem, unit
+ allows access (OFF), presents a challenge (CHALLENGE), sends
+ a one-time-password (SEND PASSWORD) to a destination
+ configured by secUserChallengeTelnetSendTo, or dials a
+ number (CALLBACK) configured with secUserCallbackNumberx"
+ ::= { secUserEntry 23 }
+ --1.3.6.1.4.1.3052.14.2.11.2.1.23
+
+secUserChallengeConsoleMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Console challenge mode: when user logs in via console, unit
+ allows access (OFF), or presents a challenge (CHALLENGE)"
+ ::= { secUserEntry 24 }
+ --1.3.6.1.4.1.3052.14.2.11.2.1.24
+
+secUserChallengeTelnetSendTo OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Email action used as the destination address for one-time-
+ password when a user logs in with a challenge mode of
+ SEND PASSWORD"
+ ::= { secUserEntry 25 }
+ --1.3.6.1.4.1.3052.14.2.11.2.1.25
+
+secUserChallengeModemSendTo OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Modem action used as the destination phone number for one-
+ time-password when a user logs in with a challenge mode of
+ SEND PASSWORD"
+ ::= { secUserEntry 26 }
+ --1.3.6.1.4.1.3052.14.2.11.2.1.26
+
+secUserChallengeExpiration OBJECT-TYPE
+ SYNTAX Integer32 (0..180)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time (in minutes) after which a one-time-password is sent
+ that it can be used to log in"
+ ::= { secUserEntry 27 }
+ --1.3.6.1.4.1.3052.14.2.11.2.1.27
+
+
+--***************************************************************************************
+--Factory Security Section 2.11.3
+--***************************************************************************************
+
+sfEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable factory access"
+ ::= { secFactory 1 }
+ --1.3.6.1.4.1.3052.14.2.11.3.1
+
+sfSecret OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Secret used for factory access"
+ ::= { secFactory 2 }
+ --1.3.6.1.4.1.3052.14.2.11.3.2
+
+
+--***************************************************************************************
+--SSH Security Section 2.11.3
+--***************************************************************************************
+
+--***************************************************************************************
+--Event Section 2.12
+--***************************************************************************************
+
+--***************************************************************************************
+--Event Core Section 2.12.1
+--***************************************************************************************
+
+
+evClassNameTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EventClassConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of classes"
+ ::= { evCore 1 }
+ --1.3.6.1.4.1.3052.14.2.12.1.1
+
+evClassNameEntry OBJECT-TYPE
+ SYNTAX EventClassConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of classes"
+ INDEX { evClassNameIndex }
+ ::= { evClassNameTable 1 }
+ --1.3.6.1.4.1.3052.14.2.12.1.1.1
+
+evClassNameIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..12)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of classes"
+ ::= { evClassNameEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.12.1.1.1.1
+
+evClassName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Class name for this slot"
+ ::= { evClassNameEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.12.1.1.1.2
+
+evReminderInterval OBJECT-TYPE
+ SYNTAX Integer32 (0..65535)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Interval (minutes) between EventSensor reminder events"
+ ::= { evCore 2 }
+ --1.3.6.1.4.1.3052.14.2.12.1.2
+
+evLogEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable event log"
+ ::= { evLog 1 }
+ --1.3.6.1.4.1.3052.14.2.12.1.3.1
+
+evLogStoreAlarm OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF store data alarms in event log"
+ ::= { evLog 2 }
+ --1.3.6.1.4.1.3052.14.2.12.1.3.2
+
+evLogMaxSize OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "max size (in KB) of event log"
+ ::= { evLog 3 }
+ --1.3.6.1.4.1.3052.14.2.12.1.3.3
+
+evLogStoreSensor OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF store EventSensor events in event log"
+ ::= { evLog 4 }
+ --1.3.6.1.4.1.3052.14.2.12.1.3.4
+
+evLogTimeStampAlarms OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF put timestamps on event log entries"
+ ::= { evLog 5 }
+ --1.3.6.1.4.1.3052.14.2.12.1.3.5
+
+evLogPrependName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF prepend data event name to data alarm records in event
+ log"
+ ::= { evLog 6 }
+ --1.3.6.1.4.1.3052.14.2.12.1.3.6
+
+
+evMgmtReprocess OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number of sensors that have generated events since reset.
+ Write this to reprocess each sensor's last generated event
+ since reset. The value to write determines what kind of
+ events should be reprocessed:
+ 'all': all sensor events
+ 'cc': cc events
+ 'temperature': temperature events
+ 'humidity': humidity events
+ 'analog': analog input events"
+ ::= { evMgmt 3 }
+ --1.3.6.1.4.1.3052.14.2.12.1.4.3
+
+
+
+
+
+
+--***************************************************************************************
+--Data event section 2.12.2
+--***************************************************************************************
+
+evdExitOnTrue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF: Data alarm evaluator stops checking record against
+ alarm equations when it finds an equation that matches"
+ ::= { evdCore 1 }
+ --1.3.6.1.4.1.3052.14.2.12.2.1.1.1
+
+evdFilterAction OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "What happens to a record that matches an equation:
+ REJECT/ACCEPT"
+ ::= { evdCore 2 }
+ --1.3.6.1.4.1.3052.14.2.12.2.1.1.2
+
+evdWildCardChar OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Character (in decimal ASCII code format) used to indicate
+ wildcards in data alarm equation"
+ ::= { evdCore 3 }
+ --1.3.6.1.4.1.3052.14.2.12.2.1.1.3
+
+
+evdTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF DataEventConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of data events"
+ ::= { evData 2 }
+ --1.3.6.1.4.1.3052.14.2.12.2.2
+
+evdEntry OBJECT-TYPE
+ SYNTAX DataEventConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of data events"
+ INDEX { evdIndex }
+ ::= { evdTable 1 }
+ --1.3.6.1.4.1.3052.14.2.12.2.2.1
+
+evdIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..1000)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of data events"
+ ::= { evdEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.12.2.2.1.1
+
+evdEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable this data event"
+ ::= { evdEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.12.2.2.1.2
+
+evdName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Name for this data event"
+ ::= { evdEntry 3 }
+ --1.3.6.1.4.1.3052.14.2.12.2.2.1.3
+
+evdEquation OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Equation for this data event"
+ ::= { evdEntry 4 }
+ --1.3.6.1.4.1.3052.14.2.12.2.2.1.4
+
+evdThreshold OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number of equation matches that must happen to trigger this
+ data event"
+ ::= { evdEntry 5 }
+ --1.3.6.1.4.1.3052.14.2.12.2.2.1.5
+
+evdAutoClear OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF this data alarm is automatically cleared (re-armed)
+ upon reaching the threshold number of matches"
+ ::= { evdEntry 6 }
+ --1.3.6.1.4.1.3052.14.2.12.2.2.1.6
+
+evdClearInterval OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Interval at which this alarm is automatically cleared (no
+ bearing with evdAutoClear)"
+ ::= { evdEntry 7 }
+ --1.3.6.1.4.1.3052.14.2.12.2.2.1.7
+
+evdClearTime OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Tie of day (HH:MM) at which this data alarm is cleared (no
+ bearing with evdAutoClear)"
+ ::= { evdEntry 8 }
+ --1.3.6.1.4.1.3052.14.2.12.2.2.1.8
+
+evdActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Actions for this data event"
+ ::= { evdEntry 9 }
+ --1.3.6.1.4.1.3052.14.2.12.2.2.1.9
+
+evdClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Class for this data event"
+ ::= { evdEntry 10 }
+ --1.3.6.1.4.1.3052.14.2.12.2.2.1.10
+
+evdTrapNum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Trap number for this event"
+ ::= { evdEntry 11 }
+ --1.3.6.1.4.1.3052.14.2.12.2.2.1.11
+
+evdMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ALARM/FILTER: what is happens when this data event
+ triggers: either generate actions (mode=ALARM) )or
+ ACCEPT/REJECT (via evdFilterAction) the record
+ (mode=FILTER)"
+ ::= { evdEntry 12 }
+ --1.3.6.1.4.1.3052.14.2.12.2.2.1.12
+
+evdFieldTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF DataEventFieldConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of data event fields"
+ ::= { evData 3 }
+ --1.3.6.1.4.1.3052.14.2.12.2.3
+
+evdFieldEntry OBJECT-TYPE
+ SYNTAX DataEventFieldConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of data event fields"
+ INDEX { evdFieldIndex }
+ ::= { evdFieldTable 1 }
+ --1.3.6.1.4.1.3052.14.2.12.2.3.1
+
+evdFieldIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..16)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of data event fields"
+ ::= { evdFieldEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.12.2.3.1.1
+
+evdFieldStart OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Start position (1-based) for this data event field"
+ ::= { evdFieldEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.12.2.3.1.2
+
+evdFieldLength OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number of characters this data event field occupies"
+ ::= { evdFieldEntry 3 }
+ --1.3.6.1.4.1.3052.14.2.12.2.3.1.3
+
+evdFieldName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Start position (1-based) for this data event field"
+ ::= { evdFieldEntry 4 }
+ --1.3.6.1.4.1.3052.14.2.12.2.3.1.4
+
+evdFieldLine OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Line number (1-based, for multiline records) for this data
+ event field"
+ ::= { evdFieldEntry 5 }
+ --1.3.6.1.4.1.3052.14.2.12.2.3.1.5
+
+evdFieldType OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Alpha/Numeric type for this data event field"
+ ::= { evdFieldEntry 6 }
+ --1.3.6.1.4.1.3052.14.2.12.2.3.1.6
+
+evdMacroTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF DataEventMacroConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of data event macros"
+ ::= { evData 4 }
+ --1.3.6.1.4.1.3052.14.2.12.2.4
+
+evdMacroEntry OBJECT-TYPE
+ SYNTAX DataEventMacroConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of data event macros"
+ INDEX { evdMacroIndex }
+ ::= { evdMacroTable 1 }
+ --1.3.6.1.4.1.3052.14.2.12.2.4.1
+
+evdMacroIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..100)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of data event macros"
+ ::= { evdMacroEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.12.2.4.1.1
+
+evdMacroName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Name of this macro for use in data event equations"
+ ::= { evdMacroEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.12.2.4.1.2
+
+evdMacroEquation OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Equation for this data event macro"
+ ::= { evdMacroEntry 3 }
+ --1.3.6.1.4.1.3052.14.2.12.2.4.1.3
+
+--***************************************************************************************
+--No data event 1 Section 2.12.3
+--***************************************************************************************
+
+evNoData1Enable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable this no data event"
+ ::= { evNoData1 1 }
+ --1.3.6.1.4.1.3052.14.2.12.3.1
+
+evNoData1Actions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Actions for this no data event"
+ ::= { evNoData1 2 }
+ --1.3.6.1.4.1.3052.14.2.12.3.2
+
+evNoData1Message OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Message for this no data event"
+ ::= { evNoData1 3 }
+ --1.3.6.1.4.1.3052.14.2.12.3.3
+
+evNoData1TrapNum OBJECT-TYPE
+ SYNTAX Integer32 (0..65535)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Trap number for this no data event"
+ ::= { evNoData1 4 }
+ --1.3.6.1.4.1.3052.14.2.12.3.4
+
+evNoData1Class OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Class for this no data event"
+ ::= { evNoData1 5 }
+ --1.3.6.1.4.1.3052.14.2.12.3.5
+
+evNoData1Sched1Begin OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Schedule 1 begin time (HH:MM) for this no data event"
+ ::= { evNoData1 6 }
+ --1.3.6.1.4.1.3052.14.2.12.3.6
+
+evNoData1Sched1End OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Schedule 1 end time (HH:MM) for this no data event"
+ ::= { evNoData1 7 }
+ --1.3.6.1.4.1.3052.14.2.12.3.7
+
+evNoData1Sched1Duration OBJECT-TYPE
+ SYNTAX Integer32 (0..65535)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Duration (minutes) for schedule 1 of this no data event"
+ ::= { evNoData1 8 }
+ --1.3.6.1.4.1.3052.14.2.12.3.8
+
+evNoData1Sched2Begin OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Schedule 2 begin time (HH:MM) for this no data event"
+ ::= { evNoData1 9 }
+ --1.3.6.1.4.1.3052.14.2.12.3.9
+
+evNoData1Sched2End OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Schedule 2 end time (HH:MM) for this no data event"
+ ::= { evNoData1 10 }
+ --1.3.6.1.4.1.3052.14.2.12.3.10
+
+evNoData1Sched2Duration OBJECT-TYPE
+ SYNTAX Integer32 (0..65535)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Duration (minutes) for schedule 2 of this no data event"
+ ::= { evNoData1 11 }
+ --1.3.6.1.4.1.3052.14.2.12.3.11
+
+evNoData1PortEnableTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF NoDataEvent1PortEnableConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of no data event 1 port enables"
+ ::= { evNoData1 12 }
+ --1.3.6.1.4.1.3052.14.2.12.3.12
+
+evNoData1PortEnableEntry OBJECT-TYPE
+ SYNTAX NoDataEvent1PortEnableConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of no data event 1 port enables"
+ INDEX { evNoData1PortEnableIndex }
+ ::= { evNoData1PortEnableTable 1 }
+ --1.3.6.1.4.1.3052.14.2.12.3.12.1
+
+evNoData1PortEnableIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..16)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of no data event 1 port enables"
+ ::= { evNoData1PortEnableEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.12.3.12.1.1
+
+evNoData1PortEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF: no data event 1 observes this port"
+ ::= { evNoData1PortEnableEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.12.3.12.1.2
+
+evNoData1Exclusions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Exclusions (space-separated MM/DD-formatted dates) for this
+ no data event"
+ ::= { evNoData1 13 }
+ --1.3.6.1.4.1.3052.14.2.12.3.13
+
+evNoData1Days OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Days of the week on which this no event is active"
+ ::= { evNoData1 14 }
+ --1.3.6.1.4.1.3052.14.2.12.3.14
+
+--***************************************************************************************
+--No data event 2 Section 2.12.4
+--***************************************************************************************
+
+evNoData2Enable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable this no data event"
+ ::= { evNoData2 1 }
+ --1.3.6.1.4.1.3052.14.2.12.4.1
+
+evNoData2Actions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Actions for this no data event"
+ ::= { evNoData2 2 }
+ --1.3.6.1.4.1.3052.14.2.12.4.2
+
+evNoData2Message OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Message for this no data event"
+ ::= { evNoData2 3 }
+ --1.3.6.1.4.1.3052.14.2.12.4.3
+
+evNoData2TrapNum OBJECT-TYPE
+ SYNTAX Integer32 (505..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Trap number for this no data event"
+ ::= { evNoData2 4 }
+ --1.3.6.1.4.1.3052.14.2.12.4.4
+
+evNoData2Class OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Class for this no data event"
+ ::= { evNoData2 5 }
+ --1.3.6.1.4.1.3052.14.2.12.4.5
+
+evNoData2Sched1Begin OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Schedule 1 begin time (HH:MM) for this no data event"
+ ::= { evNoData2 6 }
+ --1.3.6.1.4.1.3052.14.2.12.4.6
+
+evNoData2Sched1End OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Schedule 1 end time (HH:MM) for this no data event"
+ ::= { evNoData2 7 }
+ --1.3.6.1.4.1.3052.14.2.12.4.7
+
+evNoData2Sched1Duration OBJECT-TYPE
+ SYNTAX Integer32 (0..65535)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Duration (minutes) for schedule 1 of this no data event"
+ ::= { evNoData2 8 }
+ --1.3.6.1.4.1.3052.14.2.12.4.8
+
+evNoData2Sched2Begin OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Schedule 2 begin time (HH:MM) for this no data event"
+ ::= { evNoData2 9 }
+ --1.3.6.1.4.1.3052.14.2.12.4.9
+
+evNoData2Sched2End OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Schedule 2 end time (HH:MM) for this no data event"
+ ::= { evNoData2 10 }
+ --1.3.6.1.4.1.3052.14.2.12.4.10
+
+evNoData2Sched2Duration OBJECT-TYPE
+ SYNTAX Integer32 (0..65535)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Duration (minutes) for schedule 2 of this no data event"
+ ::= { evNoData2 11 }
+ --1.3.6.1.4.1.3052.14.2.12.4.11
+
+evNoData2PortEnableTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF NoDataEvent2PortEnableConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of no data event 2 port enables"
+ ::= { evNoData2 12 }
+ --1.3.6.1.4.1.3052.14.2.12.4.12
+
+evNoData2PortEnableEntry OBJECT-TYPE
+ SYNTAX NoDataEvent2PortEnableConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of no data event 2 port enables"
+ INDEX { evNoData2PortEnableIndex }
+ ::= { evNoData2PortEnableTable 1 }
+ --1.3.6.1.4.1.3052.14.2.12.4.12.1
+
+evNoData2PortEnableIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..16)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of no data event 2 port enables"
+ ::= { evNoData2PortEnableEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.12.4.12.1.1
+
+evNoData2PortEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF: no data event 2 observes this port"
+ ::= { evNoData2PortEnableEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.12.4.12.1.2
+
+evNoData2Exclusions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Exclusions (space-separated MM/DD-formatted dates) for this
+ no data event"
+ ::= { evNoData2 13 }
+ --1.3.6.1.4.1.3052.14.2.12.4.13
+
+evNoData2Days OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Days of the week on which this no event is active"
+ ::= { evNoData2 14 }
+ --1.3.6.1.4.1.3052.14.2.12.4.14
+
+--***************************************************************************************
+--Scheduled Event 1 Section 2.12.5
+--***************************************************************************************
+
+evSched1Enable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable this scheduled event"
+ ::= { evSched1 1 }
+ --1.3.6.1.4.1.3052.14.2.12.5.1
+
+evSched1Actions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Actions for this scheduled event"
+ ::= { evSched1 2 }
+ --1.3.6.1.4.1.3052.14.2.12.5.2
+
+evSched1Message OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Message for this scheduled event"
+ ::= { evSched1 3 }
+ --1.3.6.1.4.1.3052.14.2.12.5.3
+
+evSched1TrapNum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Trap number for this scheduled event"
+ ::= { evSched1 4 }
+ --1.3.6.1.4.1.3052.14.2.12.5.4
+
+evSched1Class OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Class for this scheduled event"
+ ::= { evSched1 5 }
+ --1.3.6.1.4.1.3052.14.2.12.5.5
+
+evSched1Sunday OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time on Sunday (HH:MM) when this scheduled event triggers"
+ ::= { evSched1 6 }
+ --1.3.6.1.4.1.3052.14.2.12.5.6
+
+evSched1Monday OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time on Monday (HH:MM) when this scheduled event triggers"
+ ::= { evSched1 7 }
+ --1.3.6.1.4.1.3052.14.2.12.5.7
+
+evSched1Tuesday OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time on Tuesday (HH:MM) when this scheduled event triggers"
+ ::= { evSched1 8 }
+ --1.3.6.1.4.1.3052.14.2.12.5.8
+
+evSched1Wednesday OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time on Wednesday (HH:MM) when this scheduled event triggers"
+ ::= { evSched1 9 }
+ --1.3.6.1.4.1.3052.14.2.12.5.9
+
+evSched1Thursday OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time on Thursday (HH:MM) when this scheduled event triggers"
+ ::= { evSched1 10 }
+ --1.3.6.1.4.1.3052.14.2.12.5.10
+
+evSched1Friday OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time on Friday (HH:MM) when this scheduled event triggers"
+ ::= { evSched1 11 }
+ --1.3.6.1.4.1.3052.14.2.12.5.11
+
+evSched1Saturday OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time on Saturday (HH:MM) when this scheduled event triggers"
+ ::= { evSched1 12 }
+ --1.3.6.1.4.1.3052.14.2.12.5.12
+
+evSched1Exclusions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Exclusions (space-separated MM/DD-formatted dates) for this
+ scheduled event"
+ ::= { evSched1 13 }
+ --1.3.6.1.4.1.3052.14.2.12.5.13
+
+
+--***************************************************************************************
+--Scheduled Event 2 Section 2.12.6
+--***************************************************************************************
+
+evSched2Enable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable this scheduled event"
+ ::= { evSched2 1 }
+ --1.3.6.1.4.1.3052.14.2.12.6.1
+
+evSched2Actions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Actions for this scheduled event"
+ ::= { evSched2 2 }
+ --1.3.6.1.4.1.3052.14.2.12.6.2
+
+evSched2Message OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Message for this scheduled event"
+ ::= { evSched2 3 }
+ --1.3.6.1.4.1.3052.14.2.12.6.3
+
+evSched2TrapNum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Trap number for this scheduled event"
+ ::= { evSched2 4 }
+ --1.3.6.1.4.1.3052.14.2.12.6.4
+
+evSched2Class OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Class for this scheduled event"
+ ::= { evSched2 5 }
+ --1.3.6.1.4.1.3052.14.2.12.6.5
+
+evSched2Sunday OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time on Sunday (HH:MM) when this scheduled event triggers"
+ ::= { evSched2 6 }
+ --1.3.6.1.4.1.3052.14.2.12.6.6
+
+evSched2Monday OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time on Monday (HH:MM) when this scheduled event triggers"
+ ::= { evSched2 7 }
+ --1.3.6.1.4.1.3052.14.2.12.6.7
+
+evSched2Tuesday OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time on Tuesday (HH:MM) when this scheduled event triggers"
+ ::= { evSched2 8 }
+ --1.3.6.1.4.1.3052.14.2.12.6.8
+
+evSched2Wednesday OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time on Wednesday (HH:MM) when this scheduled event triggers"
+ ::= { evSched2 9 }
+ --1.3.6.1.4.1.3052.14.2.12.6.9
+
+evSched2Thursday OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time on Thursday (HH:MM) when this scheduled event triggers"
+ ::= { evSched2 10 }
+ --1.3.6.1.4.1.3052.14.2.12.6.10
+
+evSched2Friday OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time on Friday (HH:MM) when this scheduled event triggers"
+ ::= { evSched2 11 }
+ --1.3.6.1.4.1.3052.14.2.12.6.11
+
+evSched2Saturday OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time on Saturday (HH:MM) when this scheduled event triggers"
+ ::= { evSched2 12 }
+ --1.3.6.1.4.1.3052.14.2.12.6.12
+
+evSched2Exclusions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Exclusions (space-separated MM/DD-formatted dates) for this
+ scheduled event"
+ ::= { evSched2 13 }
+ --1.3.6.1.4.1.3052.14.2.12.6.13
+
+--***************************************************************************************
+--Serial Handshaking Low Section 2.12.7
+--***************************************************************************************
+
+evShskLowTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SerialHandshakingLowEventConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of serial handshaking low events"
+ ::= { event 7 }
+ --1.3.6.1.4.1.3052.14.2.12.7
+
+evShskLowEntry OBJECT-TYPE
+ SYNTAX SerialHandshakingLowEventConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of serial handshaking low events"
+ INDEX { evShskLowIndex }
+ ::= { evShskLowTable 1 }
+ --1.3.6.1.4.1.3052.14.2.12.7.1
+
+evShskLowIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..16)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of serial handshaking low events"
+ ::= { evShskLowEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.12.7.1.1
+
+evShskLowEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF: enable the serial handshaking low event for this port"
+ ::= { evShskLowEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.12.7.1.2
+
+evShskLowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Actions for the serial handshaking low event for this port"
+ ::= { evShskLowEntry 3 }
+ --1.3.6.1.4.1.3052.14.2.12.7.1.3
+
+evShskLowMessage OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Message for the serial handshaking low event for this port"
+ ::= { evShskLowEntry 4 }
+ --1.3.6.1.4.1.3052.14.2.12.7.1.4
+
+evShskLowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Class for the serial handshaking low event for this port"
+ ::= { evShskLowEntry 5 }
+ --1.3.6.1.4.1.3052.14.2.12.7.1.5
+
+evShskLowTrapNum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Trap number for the serial handshaking low event for this port"
+ ::= { evShskLowEntry 6 }
+ --1.3.6.1.4.1.3052.14.2.12.7.1.6
+
+
+--***************************************************************************************
+--Serial Handshaking High Section 2.12.8
+--***************************************************************************************
+
+evShskHighTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SerialHandshakingHighEventConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of serial handshaking high events"
+ ::= { event 8 }
+ --1.3.6.1.4.1.3052.14.2.12.8
+
+evShskHighEntry OBJECT-TYPE
+ SYNTAX SerialHandshakingHighEventConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of serial handshaking high events"
+ INDEX { evShskHighIndex }
+ ::= { evShskHighTable 1 }
+ --1.3.6.1.4.1.3052.14.2.12.8.1
+
+evShskHighIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..16)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of serial handshaking high events"
+ ::= { evShskHighEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.12.8.1.1
+
+evShskHighEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF: enable the serial handshaking high event for this
+ port"
+ ::= { evShskHighEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.12.8.1.2
+
+evShskHighActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Actions for the serial handshaking high event for this port"
+ ::= { evShskHighEntry 3 }
+ --1.3.6.1.4.1.3052.14.2.12.8.1.3
+
+evShskHighMessage OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Message for the serial handshaking high event for this port"
+ ::= { evShskHighEntry 4 }
+ --1.3.6.1.4.1.3052.14.2.12.8.1.4
+
+evShskHighClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Class for the serial handshaking high event for this port"
+ ::= { evShskHighEntry 5 }
+ --1.3.6.1.4.1.3052.14.2.12.8.1.5
+
+evShskHighTrapNum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Trap number for the serial handshaking high event for this
+ port"
+ ::= { evShskHighEntry 6 }
+ --1.3.6.1.4.1.3052.14.2.12.8.1.6
+
+
+
+--***************************************************************************************
+--No Sensor Event Section 2.12.9
+--***************************************************************************************
+
+evNoSensorTimeout OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Timeout (seconds) after which an EventSensor becomes
+ unresponsive that this event is triggered"
+ ::= { evNoSensor 1 }
+ --1.3.6.1.4.1.3052.14.2.12.9.1
+
+evNoSensorActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Actions for no sensor event"
+ ::= { evNoSensor 2 }
+ --1.3.6.1.4.1.3052.14.2.12.9.2
+
+evNoSensorTrapNum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Trap number for no sensor event"
+ ::= { evNoSensor 3 }
+ --1.3.6.1.4.1.3052.14.2.12.9.3
+
+evNoSensorClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Class for no sensor event"
+ ::= { evNoSensor 4 }
+ --1.3.6.1.4.1.3052.14.2.12.9.4
+
+
+
+--***************************************************************************************
+--Fuel Sensor Config Section 2.12.11
+--***************************************************************************************
+
+
+fuelSensorGeneralTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF FuelSensorConfigGeneral
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table organizes general fuel sensor attributes."
+ ::= { fuelSensor 1 }
+ --1.3.6.1.4.1.3052.14.2.12.11.1
+
+fsGenEntry OBJECT-TYPE
+ SYNTAX FuelSensorConfigGeneral
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for fuel sensor general config table."
+ INDEX { fsGenIndex }
+ ::= { fuelSensorGeneralTable 1 }
+ --1.3.6.1.4.1.3052.14.2.12.11.1.1
+
+fsGenIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..3)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Which fuel sensor in the fuel sensor general config table."
+ ::= { fsGenEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.12.11.1.1.1
+
+fsGenName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor name."
+ ::= { fsGenEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.12.11.1.1.2
+
+fsGenSensorType OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Type of fuel sensor in use; NONE disables the fuel sensor."
+ ::= { fsGenEntry 3 }
+ --1.3.6.1.4.1.3052.14.2.12.11.1.1.3
+
+fsGenDistanceUnit OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Distance units in use when setting and indicating tank dimensions."
+ ::= { fsGenEntry 4 }
+ --1.3.6.1.4.1.3052.14.2.12.11.1.1.4
+
+fsGenRawValueTop OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Analog input reading corresponding to the SENSOR FULL point."
+ ::= { fsGenEntry 5 }
+ --1.3.6.1.4.1.3052.14.2.12.11.1.1.5
+
+fsGenTopOffset OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Distance, in the specified distance unit, between the SENSOR FULL
+ point and the TANK FULL point. The value is positive if the
+ SENSOR FULL point is above the TANK FULL point, and negative if it is
+ below."
+ ::= { fsGenEntry 6 }
+ --1.3.6.1.4.1.3052.14.2.12.11.1.1.6
+
+fsGenRawValueBottom OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Analog input reading corresponding to the minimum fluid height
+ measurable by the fuel sensor."
+ ::= { fsGenEntry 7 }
+ --1.3.6.1.4.1.3052.14.2.12.11.1.1.7
+
+fsGenBottomOffset OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Distance, in the specified distance unit, between the SENSOR EMPTY
+ point and the TANK EMPTY point. The value is positive if the
+ SENSOR EMPTY point is above the TANK EMPTY point, and negative if it
+ is below."
+ ::= { fsGenEntry 8 }
+ --1.3.6.1.4.1.3052.14.2.12.11.1.1.8
+
+fsGenInputES OBJECT-TYPE
+ SYNTAX Integer32 (1..200)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Which eventsensor contains the analog input associated with this fuel
+ sensor. Allowed values are 200 (for internal ES), or 1-16."
+ ::= { fsGenEntry 9 }
+ --1.3.6.1.4.1.3052.14.2.12.11.1.1.9
+
+fsGenInputPoint OBJECT-TYPE
+ SYNTAX Integer32 (1..16)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Which analog input point, on the specified eventsensor, that is
+ associated with the fuel sensor."
+ ::= { fsGenEntry 10 }
+ --1.3.6.1.4.1.3052.14.2.12.11.1.1.10
+
+fsGenFilterAveraging OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor filter averaging factor."
+ ::= { fsGenEntry 11 }
+ --1.3.6.1.4.1.3052.14.2.12.11.1.1.11
+
+fsGenSysrepEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor System Reporting enable."
+ ::= { fsGenEntry 12 }
+ --1.3.6.1.4.1.3052.14.2.12.11.1.1.12
+
+fsGenSysrepThreshold OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor System Reporting threshold (floating point value)."
+ ::= { fsGenEntry 13 }
+ --1.3.6.1.4.1.3052.14.2.12.11.1.1.13
+
+fsGenSysrepLimit OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor System Reporting limit."
+ ::= { fsGenEntry 14 }
+ --1.3.6.1.4.1.3052.14.2.12.11.1.1.14
+
+fsGenSysrepPackage OBJECT-TYPE
+ SYNTAX Integer32 (0..10)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor System Reporting package number."
+ ::= { fsGenEntry 15 }
+ --1.3.6.1.4.1.3052.14.2.12.11.1.1.15
+
+fsGenSysrepType OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor ASM profile type."
+ ::= { fsGenEntry 16 }
+ --1.3.6.1.4.1.3052.14.2.12.11.1.1.16
+
+fsGenEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor enable."
+ ::= { fsGenEntry 17 }
+ --1.3.6.1.4.1.3052.14.2.12.11.1.1.17
+
+
+fuelSensorTankTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF FuelSensorConfigTank
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table organizes tank-specific fuel sensor attributes."
+ ::= { fuelSensor 2 }
+ --1.3.6.1.4.1.3052.14.2.12.11.2
+
+fsTankEntry OBJECT-TYPE
+ SYNTAX FuelSensorConfigTank
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for fuel sensor tank config table."
+ INDEX { fsTankIndex }
+ ::= { fuelSensorTankTable 1 }
+ --1.3.6.1.4.1.3052.14.2.12.11.2.1
+
+fsTankIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..3)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Which fuel sensor in the fuel sensor tank config table."
+ ::= { fsTankEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.12.11.2.1.1
+
+fsTankHeight OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Height of the tank, from the TANK EMPTY point to the TANK FULL point,
+ in the specified distance unit (i.e. TANK HEIGHT). This is a
+ floating point value."
+ ::= { fsTankEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.12.11.2.1.2
+
+fsTankDimA OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Tank dimension measurement A for certain tank profiles. For
+ HORIZ OVAL, this is the length of the straight section. This is a
+ floating point value."
+ ::= { fsTankEntry 3 }
+ --1.3.6.1.4.1.3052.14.2.12.11.2.1.3
+
+fsTankDimB OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Tank dimension measurement B for certain tank profiles. For
+ HORIZ OVAL, this is the radius of the curved section. This is a
+ floating point value."
+ ::= { fsTankEntry 4 }
+ --1.3.6.1.4.1.3052.14.2.12.11.2.1.4
+
+fsTankVolume OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "How many volume units the tank contains, when full. This is a
+ floating point value."
+ ::= { fsTankEntry 5 }
+ --1.3.6.1.4.1.3052.14.2.12.11.2.1.5
+
+fsTankVolumeUnit OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Name of the unit representing fluid volume in the tank. This is only
+ used for display purposes; it does not affect the volume calculation."
+ ::= { fsTankEntry 6 }
+ --1.3.6.1.4.1.3052.14.2.12.11.2.1.6
+
+fsTankShape OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The shape of the fuel tank. A value of LINEAR produces a fluid
+ volume reading that is directly proportional to fluid height. The
+ HORIZ CYL and HORIZ OVAL settings use a hard-coded formula to
+ calculate the volume. The CUSTOM setting uses a strapping table that
+ must be configured as well (see fuelSensorCustomTankTable)."
+ ::= { fsTankEntry 7 }
+ --1.3.6.1.4.1.3052.14.2.12.11.2.1.7
+
+
+fuelSensorCustomTankTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF FuelSensorConfigCustomTankStrapping
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table organizes the custom tank strapping table. Each fuel
+ sensor has a table of height/volume pairs in service only when the tank
+ shape (fsTankShape) in CUSTOM. This allows the unit to calculate
+ volumes for nonstandard tank shapes, to the degree that accurate
+ height/volume measurements can be configured. This SNMP table has two
+ indexes: the first for which fuel sensor and the second for which
+ height/volume pair."
+ ::= { fuelSensor 3 }
+ --1.3.6.1.4.1.3052.14.2.12.11.3
+
+fsCustomTankEntry OBJECT-TYPE
+ SYNTAX FuelSensorConfigCustomTankStrapping
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for fuel sensor custom tank config table."
+ INDEX { fsCustomTankIndexFS, fsCustomTankIndexDatum }
+ ::= { fuelSensorCustomTankTable 1 }
+ --1.3.6.1.4.1.3052.14.2.12.11.3.1
+
+fsCustomTankIndexFS OBJECT-TYPE
+ SYNTAX Integer32 (1..3)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Which fuel sensor in the fuel sensor tank config table. This is the
+ first of two indexes for this SNMP table."
+ ::= { fsCustomTankEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.12.11.3.1.1
+
+fsCustomTankIndexDatum OBJECT-TYPE
+ SYNTAX Integer32 (1..32)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Which hight/volume pair: there are 32 pairs per fuel sensor. This is
+ the second of two indexes for this SNMP table."
+ ::= { fsCustomTankEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.12.11.3.1.2
+
+fsCustomTankHeight OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Height of custom tank height/volume pair. This is a floating point
+ value."
+ ::= { fsCustomTankEntry 3 }
+ --1.3.6.1.4.1.3052.14.2.12.11.3.1.3
+
+fsCustomTankVolume OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Volume of custom tank height/volume pair. This is a floating point
+ value."
+ ::= { fsCustomTankEntry 4 }
+ --1.3.6.1.4.1.3052.14.2.12.11.3.1.4
+
+
+fuelSensorVolumeTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF FuelSensorConfigVolume
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table organizes volume-event-specific fuel sensor attributes."
+ ::= { fuelSensor 4 }
+ --1.3.6.1.4.1.3052.14.2.12.11.4
+
+fsVolumeEntry OBJECT-TYPE
+ SYNTAX FuelSensorConfigVolume
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for fuel sensor volume event config table."
+ INDEX { fsVolumeIndex }
+ ::= { fuelSensorVolumeTable 1 }
+ --1.3.6.1.4.1.3052.14.2.12.11.4.1
+
+fsVolumeIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..3)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Which fuel sensor in the fuel sensor volume event config table."
+ ::= { fsVolumeEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.12.11.4.1.1
+
+fsVolumeEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable fuel sensor volume events."
+ ::= { fsVolumeEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.12.11.4.1.2
+
+fsVolumeDeadband OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor deadband (hysteresis). This is a floating point value."
+ ::= { fsVolumeEntry 3 }
+ --1.3.6.1.4.1.3052.14.2.12.11.4.1.3
+
+fsVolumeVHighValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume very high event threshold value. This is a
+ floating point value."
+ ::= { fsVolumeEntry 4 }
+ --1.3.6.1.4.1.3052.14.2.12.11.4.1.4
+
+fsVolumeVHighActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume very high event threshold actions."
+ ::= { fsVolumeEntry 5 }
+ --1.3.6.1.4.1.3052.14.2.12.11.4.1.5
+
+fsVolumeVHighTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (519..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume very high event threshold trap number."
+ ::= { fsVolumeEntry 6 }
+ --1.3.6.1.4.1.3052.14.2.12.11.4.1.6
+
+fsVolumeVHighClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume very high event threshold class (severity)."
+ ::= { fsVolumeEntry 7 }
+ --1.3.6.1.4.1.3052.14.2.12.11.4.1.7
+
+fsVolumeHighValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume high event threshold value. This is a floating
+ point value."
+ ::= { fsVolumeEntry 8 }
+ --1.3.6.1.4.1.3052.14.2.12.11.4.1.8
+
+fsVolumeHighActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume high event threshold actions."
+ ::= { fsVolumeEntry 9 }
+ --1.3.6.1.4.1.3052.14.2.12.11.4.1.9
+
+fsVolumeHighTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (519..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume high event threshold trap number."
+ ::= { fsVolumeEntry 10 }
+ --1.3.6.1.4.1.3052.14.2.12.11.4.1.10
+
+fsVolumeHighClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume high event threshold class (severity)."
+ ::= { fsVolumeEntry 11 }
+ --1.3.6.1.4.1.3052.14.2.12.11.4.1.11
+
+fsVolumeNormalActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume return to normal actions."
+ ::= { fsVolumeEntry 12 }
+ --1.3.6.1.4.1.3052.14.2.12.11.4.1.12
+
+fsVolumeNormalTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (519..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume return to normal trap number."
+ ::= { fsVolumeEntry 13 }
+ --1.3.6.1.4.1.3052.14.2.12.11.4.1.13
+
+fsVolumeNormalClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume return to normal class (severity)."
+ ::= { fsVolumeEntry 14 }
+ --1.3.6.1.4.1.3052.14.2.12.11.4.1.14
+
+fsVolumeLowValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume low event threshold value. This is a floating
+ point value."
+ ::= { fsVolumeEntry 15 }
+ --1.3.6.1.4.1.3052.14.2.12.11.4.1.15
+
+fsVolumeLowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume low event threshold actions."
+ ::= { fsVolumeEntry 16 }
+ --1.3.6.1.4.1.3052.14.2.12.11.4.1.16
+
+fsVolumeLowTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (519..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume low event threshold trap number."
+ ::= { fsVolumeEntry 17 }
+ --1.3.6.1.4.1.3052.14.2.12.11.4.1.17
+
+fsVolumeLowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume low event threshold class (severity)."
+ ::= { fsVolumeEntry 18 }
+ --1.3.6.1.4.1.3052.14.2.12.11.4.1.18
+
+fsVolumeVLowValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume very low event threshold value. This is a
+ floating point value."
+ ::= { fsVolumeEntry 19 }
+ --1.3.6.1.4.1.3052.14.2.12.11.4.1.19
+
+fsVolumeVLowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume very low event threshold actions."
+ ::= { fsVolumeEntry 20 }
+ --1.3.6.1.4.1.3052.14.2.12.11.4.1.20
+
+fsVolumeVLowTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (519..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume very low event threshold trap number."
+ ::= { fsVolumeEntry 21 }
+ --1.3.6.1.4.1.3052.14.2.12.11.4.1.21
+
+fsVolumeVLowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume very low event threshold class (severity)."
+ ::= { fsVolumeEntry 22 }
+ --1.3.6.1.4.1.3052.14.2.12.11.4.1.22
+
+
+
+fuelSensorDisconnectTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF FuelSensorConfigDisconnect
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table organizes disconnect-event-specific fuel sensor attributes."
+ ::= { fuelSensor 5 }
+ --1.3.6.1.4.1.3052.14.2.12.11.5
+
+fsDiscEntry OBJECT-TYPE
+ SYNTAX FuelSensorConfigDisconnect
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for fuel sensor disconnect event config table."
+ INDEX { fsDiscIndex }
+ ::= { fuelSensorDisconnectTable 1 }
+ --1.3.6.1.4.1.3052.14.2.12.11.5.1
+
+fsDiscIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..3)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Which fuel sensor in the fuel sensor disconnect event config table."
+ ::= { fsDiscEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.12.11.5.1.1
+
+fsDiscEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor disconnect event enable."
+ ::= { fsDiscEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.12.11.5.1.2
+
+fsDiscHighValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High end of input value range when fuel sensor is disconnected. This
+ is in the units of the analog input value."
+ ::= { fsDiscEntry 3 }
+ --1.3.6.1.4.1.3052.14.2.12.11.5.1.3
+
+fsDiscLowValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low end of input value range when fuel sensor is disconnected. This
+ is in the units of the analog input value."
+ ::= { fsDiscEntry 4 }
+ --1.3.6.1.4.1.3052.14.2.12.11.5.1.4
+
+fsDiscActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor disconnect event actions."
+ ::= { fsDiscEntry 5 }
+ --1.3.6.1.4.1.3052.14.2.12.11.5.1.5
+
+fsDiscTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (515..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor disconnect event trap number."
+ ::= { fsDiscEntry 6 }
+ --1.3.6.1.4.1.3052.14.2.12.11.5.1.6
+
+fsDiscClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor disconnect event class (severity)."
+ ::= { fsDiscEntry 7 }
+ --1.3.6.1.4.1.3052.14.2.12.11.5.1.7
+
+fsDiscNormalActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor disconnect return to normal actions."
+ ::= { fsDiscEntry 8 }
+ --1.3.6.1.4.1.3052.14.2.12.11.5.1.8
+
+fsDiscNormalTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (515..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor disconnect return to normal trap number."
+ ::= { fsDiscEntry 9 }
+ --1.3.6.1.4.1.3052.14.2.12.11.5.1.9
+
+fsDiscNormalClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor disconnect return to normal class (severity)."
+ ::= { fsDiscEntry 10 }
+ --1.3.6.1.4.1.3052.14.2.12.11.5.1.10
+
+
+--***************************************************************************************
+--AC Power Monitor Config Section 2.12.12
+--***************************************************************************************
+
+acpmGeneralTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ACPMConfigGeneral
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table organizes general AC power monitor attributes."
+ ::= { acPowerMonitor 1 }
+ --1.3.6.1.4.1.3052.14.2.12.12.1
+
+acpmGenEntry OBJECT-TYPE
+ SYNTAX ACPMConfigGeneral
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for AC power monitor general config table."
+ INDEX { acpmGenIndex }
+ ::= { acpmGeneralTable 1 }
+ --1.3.6.1.4.1.3052.14.2.12.12.1.1
+
+acpmGenIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..6)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Which AC power monitor in the AC power monitor general config table."
+ ::= { acpmGenEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.12.12.1.1.1
+
+acpmGenDevice OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Model of the AC power monitor device. The unit needs this setting to
+ know which registers to poll for the various data items, among other
+ things."
+ ::= { acpmGenEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.12.12.1.1.2
+
+acpmGenName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Name for the AC power monitor device."
+ ::= { acpmGenEntry 3 }
+ --1.3.6.1.4.1.3052.14.2.12.12.1.1.3
+
+acpmGenAddress OBJECT-TYPE
+ SYNTAX Integer32 (1..247)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Modbus address of the AC power monitor device."
+ ::= { acpmGenEntry 4 }
+ --1.3.6.1.4.1.3052.14.2.12.12.1.1.4
+
+acpmGenPtRatio OBJECT-TYPE
+ SYNTAX Integer32 (1..10000)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ratio of secondary turns to primary turns on potential transformers
+ (PT)."
+ ::= { acpmGenEntry 5 }
+ --1.3.6.1.4.1.3052.14.2.12.12.1.1.5
+
+acpmGenCtRatio OBJECT-TYPE
+ SYNTAX Integer32 (1..10000)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ratio of secondary turns to primary turns on current transformers
+ (CT)."
+ ::= { acpmGenEntry 6 }
+ --1.3.6.1.4.1.3052.14.2.12.12.1.1.6
+
+acpmGenPowerType OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Type of power being monitored."
+ ::= { acpmGenEntry 7 }
+ --1.3.6.1.4.1.3052.14.2.12.12.1.1.7
+
+acpmGenSysrepPackage OBJECT-TYPE
+ SYNTAX Integer32 (0..10)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "System reporting package number."
+ ::= { acpmGenEntry 8 }
+ --1.3.6.1.4.1.3052.14.2.12.12.1.1.8
+
+acpmGenSysrepType OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ASM profile type."
+ ::= { acpmGenEntry 9 }
+ --1.3.6.1.4.1.3052.14.2.12.12.1.1.9
+
+acpmGenEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "AC power monitor enable."
+ ::= { acpmGenEntry 10 }
+ --1.3.6.1.4.1.3052.14.2.12.12.1.1.10
+
+
+acpmAvgVoltageTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ACPMConfigAvgVoltage
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table organizes AC power monitor average voltage attributes."
+ ::= { acPowerMonitor 2 }
+ --1.3.6.1.4.1.3052.14.2.12.12.2
+
+acpmAvgVoltageEntry OBJECT-TYPE
+ SYNTAX ACPMConfigAvgVoltage
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for AC power monitor average voltage config table."
+ INDEX { acpmAvgVoltageIndex }
+ ::= { acpmAvgVoltageTable 1 }
+ --1.3.6.1.4.1.3052.14.2.12.12.2.1
+
+acpmAvgVoltageIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..6)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Which AC power monitor in the AC power monitor average voltage config
+ table."
+ ::= { acpmAvgVoltageEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.12.12.2.1.1
+
+acpmAvgVoltageEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable AC power monitor average voltage events."
+ ::= { acpmAvgVoltageEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.12.12.2.1.2
+
+acpmAvgVoltageDeadband OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Deadband (hysteresis) for average voltage event. This is a floating
+ point value."
+ ::= { acpmAvgVoltageEntry 3 }
+ --1.3.6.1.4.1.3052.14.2.12.12.2.1.3
+
+acpmAvgVoltageVHighValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event threshold. This is a floating point value."
+ ::= { acpmAvgVoltageEntry 4 }
+ --1.3.6.1.4.1.3052.14.2.12.12.2.1.4
+
+acpmAvgVoltageVHighActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event actions."
+ ::= { acpmAvgVoltageEntry 5 }
+ --1.3.6.1.4.1.3052.14.2.12.12.2.1.5
+
+acpmAvgVoltageVHighTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (520..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event trap number."
+ ::= { acpmAvgVoltageEntry 6 }
+ --1.3.6.1.4.1.3052.14.2.12.12.2.1.6
+
+acpmAvgVoltageVHighClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event class."
+ ::= { acpmAvgVoltageEntry 7 }
+ --1.3.6.1.4.1.3052.14.2.12.12.2.1.7
+
+acpmAvgVoltageHighValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event threshold. This is a floating point value."
+ ::= { acpmAvgVoltageEntry 8 }
+ --1.3.6.1.4.1.3052.14.2.12.12.2.1.8
+
+acpmAvgVoltageHighActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event actions."
+ ::= { acpmAvgVoltageEntry 9 }
+ --1.3.6.1.4.1.3052.14.2.12.12.2.1.9
+
+acpmAvgVoltageHighTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (520..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event trap number."
+ ::= { acpmAvgVoltageEntry 10 }
+ --1.3.6.1.4.1.3052.14.2.12.12.2.1.10
+
+acpmAvgVoltageHighClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event class."
+ ::= { acpmAvgVoltageEntry 11 }
+ --1.3.6.1.4.1.3052.14.2.12.12.2.1.11
+
+acpmAvgVoltageNormalActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return to normal actions."
+ ::= { acpmAvgVoltageEntry 12 }
+ --1.3.6.1.4.1.3052.14.2.12.12.2.1.12
+
+acpmAvgVoltageNormalTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (520..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return to normal trap number."
+ ::= { acpmAvgVoltageEntry 13 }
+ --1.3.6.1.4.1.3052.14.2.12.12.2.1.13
+
+acpmAvgVoltageNormalClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return to normal class."
+ ::= { acpmAvgVoltageEntry 14 }
+ --1.3.6.1.4.1.3052.14.2.12.12.2.1.14
+
+acpmAvgVoltageLowValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event threshold. This is a floating point value."
+ ::= { acpmAvgVoltageEntry 15 }
+ --1.3.6.1.4.1.3052.14.2.12.12.2.1.15
+
+acpmAvgVoltageLowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event actions."
+ ::= { acpmAvgVoltageEntry 16 }
+ --1.3.6.1.4.1.3052.14.2.12.12.2.1.16
+
+acpmAvgVoltageLowTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (520..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event trap number."
+ ::= { acpmAvgVoltageEntry 17 }
+ --1.3.6.1.4.1.3052.14.2.12.12.2.1.17
+
+acpmAvgVoltageLowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event class."
+ ::= { acpmAvgVoltageEntry 18 }
+ --1.3.6.1.4.1.3052.14.2.12.12.2.1.18
+
+acpmAvgVoltageVLowValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event threshold. This is a floating point value."
+ ::= { acpmAvgVoltageEntry 19 }
+ --1.3.6.1.4.1.3052.14.2.12.12.2.1.19
+
+acpmAvgVoltageVLowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event actions."
+ ::= { acpmAvgVoltageEntry 20 }
+ --1.3.6.1.4.1.3052.14.2.12.12.2.1.20
+
+acpmAvgVoltageVLowTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (520..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event trap number."
+ ::= { acpmAvgVoltageEntry 21 }
+ --1.3.6.1.4.1.3052.14.2.12.12.2.1.21
+
+acpmAvgVoltageVLowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event class."
+ ::= { acpmAvgVoltageEntry 22 }
+ --1.3.6.1.4.1.3052.14.2.12.12.2.1.22
+
+acpmAvgVoltageSysrepEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "System reporting enable for average voltage telemetry."
+ ::= { acpmAvgVoltageEntry 23 }
+ --1.3.6.1.4.1.3052.14.2.12.12.2.1.23
+
+acpmAvgVoltageSysrepThreshold OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "System reporting threshold for average voltage telemetry. This is
+ a floating point value."
+ ::= { acpmAvgVoltageEntry 24 }
+ --1.3.6.1.4.1.3052.14.2.12.12.2.1.24
+
+acpmAvgVoltageSysrepLimit OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "System reporting limit for average voltage telemetry."
+ ::= { acpmAvgVoltageEntry 25 }
+ --1.3.6.1.4.1.3052.14.2.12.12.2.1.25
+
+
+acpmAvgCurrentTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ACPMConfigAvgCurrent
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table organizes AC power monitor average current attributes."
+ ::= { acPowerMonitor 3 }
+ --1.3.6.1.4.1.3052.14.2.12.12.3
+
+acpmAvgCurrentEntry OBJECT-TYPE
+ SYNTAX ACPMConfigAvgCurrent
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for AC power monitor average current config table."
+ INDEX { acpmAvgCurrentIndex }
+ ::= { acpmAvgCurrentTable 1 }
+ --1.3.6.1.4.1.3052.14.2.12.12.3.1
+
+acpmAvgCurrentIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..6)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Which AC power monitor in the AC power monitor average current
+ config table."
+ ::= { acpmAvgCurrentEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.12.12.3.1.1
+
+acpmAvgCurrentEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable AC power monitor average current events."
+ ::= { acpmAvgCurrentEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.12.12.3.1.2
+
+acpmAvgCurrentDeadband OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Deadband (hysteresis) for average current event. This is a floating
+ point value."
+ ::= { acpmAvgCurrentEntry 3 }
+ --1.3.6.1.4.1.3052.14.2.12.12.3.1.3
+
+acpmAvgCurrentVHighValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event threshold. This is a floating point value."
+ ::= { acpmAvgCurrentEntry 4 }
+ --1.3.6.1.4.1.3052.14.2.12.12.3.1.4
+
+acpmAvgCurrentVHighActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event actions."
+ ::= { acpmAvgCurrentEntry 5 }
+ --1.3.6.1.4.1.3052.14.2.12.12.3.1.5
+
+acpmAvgCurrentVHighTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (521..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event trap number."
+ ::= { acpmAvgCurrentEntry 6 }
+ --1.3.6.1.4.1.3052.14.2.12.12.3.1.6
+
+acpmAvgCurrentVHighClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event class."
+ ::= { acpmAvgCurrentEntry 7 }
+ --1.3.6.1.4.1.3052.14.2.12.12.3.1.7
+
+acpmAvgCurrentHighValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event threshold. This is a floating point value."
+ ::= { acpmAvgCurrentEntry 8 }
+ --1.3.6.1.4.1.3052.14.2.12.12.3.1.8
+
+acpmAvgCurrentHighActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event actions."
+ ::= { acpmAvgCurrentEntry 9 }
+ --1.3.6.1.4.1.3052.14.2.12.12.3.1.9
+
+acpmAvgCurrentHighTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (521..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event trap number."
+ ::= { acpmAvgCurrentEntry 10 }
+ --1.3.6.1.4.1.3052.14.2.12.12.3.1.10
+
+acpmAvgCurrentHighClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event class."
+ ::= { acpmAvgCurrentEntry 11 }
+ --1.3.6.1.4.1.3052.14.2.12.12.3.1.11
+
+acpmAvgCurrentNormalActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return to normal actions."
+ ::= { acpmAvgCurrentEntry 12 }
+ --1.3.6.1.4.1.3052.14.2.12.12.3.1.12
+
+acpmAvgCurrentNormalTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (521..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return to normal trap number."
+ ::= { acpmAvgCurrentEntry 13 }
+ --1.3.6.1.4.1.3052.14.2.12.12.3.1.13
+
+acpmAvgCurrentNormalClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return to normal class."
+ ::= { acpmAvgCurrentEntry 14 }
+ --1.3.6.1.4.1.3052.14.2.12.12.3.1.14
+
+acpmAvgCurrentLowValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event threshold. This is a floating point value."
+ ::= { acpmAvgCurrentEntry 15 }
+ --1.3.6.1.4.1.3052.14.2.12.12.3.1.15
+
+acpmAvgCurrentLowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event actions."
+ ::= { acpmAvgCurrentEntry 16 }
+ --1.3.6.1.4.1.3052.14.2.12.12.3.1.16
+
+acpmAvgCurrentLowTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (521..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event trap number."
+ ::= { acpmAvgCurrentEntry 17 }
+ --1.3.6.1.4.1.3052.14.2.12.12.3.1.17
+
+acpmAvgCurrentLowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event class."
+ ::= { acpmAvgCurrentEntry 18 }
+ --1.3.6.1.4.1.3052.14.2.12.12.3.1.18
+
+acpmAvgCurrentVLowValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event threshold. This is a floating point value."
+ ::= { acpmAvgCurrentEntry 19 }
+ --1.3.6.1.4.1.3052.14.2.12.12.3.1.19
+
+acpmAvgCurrentVLowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event actions."
+ ::= { acpmAvgCurrentEntry 20 }
+ --1.3.6.1.4.1.3052.14.2.12.12.3.1.20
+
+acpmAvgCurrentVLowTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (521..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event trap number."
+ ::= { acpmAvgCurrentEntry 21 }
+ --1.3.6.1.4.1.3052.14.2.12.12.3.1.21
+
+acpmAvgCurrentVLowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event class."
+ ::= { acpmAvgCurrentEntry 22 }
+ --1.3.6.1.4.1.3052.14.2.12.12.3.1.22
+
+acpmAvgCurrentSysrepEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "System reporting enable for average current telemetry."
+ ::= { acpmAvgCurrentEntry 23 }
+ --1.3.6.1.4.1.3052.14.2.12.12.3.1.23
+
+acpmAvgCurrentSysrepThreshold OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "System reporting threshold for average current telemetry. This is a
+ floating point value."
+ ::= { acpmAvgCurrentEntry 24 }
+ --1.3.6.1.4.1.3052.14.2.12.12.3.1.24
+
+acpmAvgCurrentSysrepLimit OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "System reporting limit for average current telemetry."
+ ::= { acpmAvgCurrentEntry 25 }
+ --1.3.6.1.4.1.3052.14.2.12.12.3.1.25
+
+
+acpmFreqTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ACPMConfigFreq
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table organizes AC power monitor frequency attributes."
+ ::= { acPowerMonitor 4 }
+ --1.3.6.1.4.1.3052.14.2.12.12.4
+
+acpmFreqEntry OBJECT-TYPE
+ SYNTAX ACPMConfigFreq
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for AC power monitor frequency config table."
+ INDEX { acpmFreqIndex }
+ ::= { acpmFreqTable 1 }
+ --1.3.6.1.4.1.3052.14.2.12.12.4.1
+
+acpmFreqIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..6)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Which AC power monitor in the AC power monitor frequency config
+ table."
+ ::= { acpmFreqEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.12.12.4.1.1
+
+acpmFreqEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable AC power monitor frequency events."
+ ::= { acpmFreqEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.12.12.4.1.2
+
+acpmFreqDeadband OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Deadband (hysteresis) for frequency event. This is a floating
+ point value."
+ ::= { acpmFreqEntry 3 }
+ --1.3.6.1.4.1.3052.14.2.12.12.4.1.3
+
+acpmFreqVHighValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event threshold. This is a floating point value."
+ ::= { acpmFreqEntry 4 }
+ --1.3.6.1.4.1.3052.14.2.12.12.4.1.4
+
+acpmFreqVHighActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event actions."
+ ::= { acpmFreqEntry 5 }
+ --1.3.6.1.4.1.3052.14.2.12.12.4.1.5
+
+acpmFreqVHighTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (522..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event trap number."
+ ::= { acpmFreqEntry 6 }
+ --1.3.6.1.4.1.3052.14.2.12.12.4.1.6
+
+acpmFreqVHighClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event class."
+ ::= { acpmFreqEntry 7 }
+ --1.3.6.1.4.1.3052.14.2.12.12.4.1.7
+
+acpmFreqHighValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event threshold. This is a floating point value."
+ ::= { acpmFreqEntry 8 }
+ --1.3.6.1.4.1.3052.14.2.12.12.4.1.8
+
+acpmFreqHighActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event actions."
+ ::= { acpmFreqEntry 9 }
+ --1.3.6.1.4.1.3052.14.2.12.12.4.1.9
+
+acpmFreqHighTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (522..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event trap number."
+ ::= { acpmFreqEntry 10 }
+ --1.3.6.1.4.1.3052.14.2.12.12.4.1.10
+
+acpmFreqHighClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event class."
+ ::= { acpmFreqEntry 11 }
+ --1.3.6.1.4.1.3052.14.2.12.12.4.1.11
+
+acpmFreqNormalActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return to normal actions."
+ ::= { acpmFreqEntry 12 }
+ --1.3.6.1.4.1.3052.14.2.12.12.4.1.12
+
+acpmFreqNormalTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (522..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return to normal trap number."
+ ::= { acpmFreqEntry 13 }
+ --1.3.6.1.4.1.3052.14.2.12.12.4.1.13
+
+acpmFreqNormalClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return to normal class."
+ ::= { acpmFreqEntry 14 }
+ --1.3.6.1.4.1.3052.14.2.12.12.4.1.14
+
+acpmFreqLowValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event threshold. This is a floating point value."
+ ::= { acpmFreqEntry 15 }
+ --1.3.6.1.4.1.3052.14.2.12.12.4.1.15
+
+acpmFreqLowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event actions."
+ ::= { acpmFreqEntry 16 }
+ --1.3.6.1.4.1.3052.14.2.12.12.4.1.16
+
+acpmFreqLowTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (522..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event trap number."
+ ::= { acpmFreqEntry 17 }
+ --1.3.6.1.4.1.3052.14.2.12.12.4.1.17
+
+acpmFreqLowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event class."
+ ::= { acpmFreqEntry 18 }
+ --1.3.6.1.4.1.3052.14.2.12.12.4.1.18
+
+acpmFreqVLowValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event threshold. This is a floating point value."
+ ::= { acpmFreqEntry 19 }
+ --1.3.6.1.4.1.3052.14.2.12.12.4.1.19
+
+acpmFreqVLowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event actions."
+ ::= { acpmFreqEntry 20 }
+ --1.3.6.1.4.1.3052.14.2.12.12.4.1.20
+
+acpmFreqVLowTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (522..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event trap number."
+ ::= { acpmFreqEntry 21 }
+ --1.3.6.1.4.1.3052.14.2.12.12.4.1.21
+
+acpmFreqVLowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event class."
+ ::= { acpmFreqEntry 22 }
+ --1.3.6.1.4.1.3052.14.2.12.12.4.1.22
+
+acpmFreqSysrepEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "System reporting enable for frequency telemetry."
+ ::= { acpmFreqEntry 23 }
+ --1.3.6.1.4.1.3052.14.2.12.12.4.1.23
+
+acpmFreqSysrepThreshold OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "System reporting threshold for frequency telemetry. This is a
+ floating point value."
+ ::= { acpmFreqEntry 24 }
+ --1.3.6.1.4.1.3052.14.2.12.12.4.1.24
+
+acpmFreqSysrepLimit OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "System reporting limit for frequency telemetry."
+ ::= { acpmFreqEntry 25 }
+ --1.3.6.1.4.1.3052.14.2.12.12.4.1.25
+
+
+acpmTotalRealPowerTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ACPMConfigTRP
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table organizes AC power monitor total real power attributes."
+ ::= { acPowerMonitor 5 }
+ --1.3.6.1.4.1.3052.14.2.12.12.5
+
+acpmTRPEntry OBJECT-TYPE
+ SYNTAX ACPMConfigTRP
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for AC power monitor total real power config table."
+ INDEX { acpmTRPIndex }
+ ::= { acpmTotalRealPowerTable 1 }
+ --1.3.6.1.4.1.3052.14.2.12.12.5.1
+
+acpmTRPIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..6)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Which AC power monitor in the AC power monitor total real power
+ config table."
+ ::= { acpmTRPEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.12.12.5.1.1
+
+acpmTRPEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable AC power monitor total real power events."
+ ::= { acpmTRPEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.12.12.5.1.2
+
+acpmTRPDeadband OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Deadband (hysteresis) for total real power event. This is a floating
+ point value."
+ ::= { acpmTRPEntry 3 }
+ --1.3.6.1.4.1.3052.14.2.12.12.5.1.3
+
+acpmTRPVHighValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event threshold. This is a floating point value."
+ ::= { acpmTRPEntry 4 }
+ --1.3.6.1.4.1.3052.14.2.12.12.5.1.4
+
+acpmTRPVHighActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event actions."
+ ::= { acpmTRPEntry 5 }
+ --1.3.6.1.4.1.3052.14.2.12.12.5.1.5
+
+acpmTRPVHighTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (523..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event trap number."
+ ::= { acpmTRPEntry 6 }
+ --1.3.6.1.4.1.3052.14.2.12.12.5.1.6
+
+acpmTRPVHighClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event class."
+ ::= { acpmTRPEntry 7 }
+ --1.3.6.1.4.1.3052.14.2.12.12.5.1.7
+
+acpmTRPHighValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event threshold. This is a floating point value."
+ ::= { acpmTRPEntry 8 }
+ --1.3.6.1.4.1.3052.14.2.12.12.5.1.8
+
+acpmTRPHighActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event actions."
+ ::= { acpmTRPEntry 9 }
+ --1.3.6.1.4.1.3052.14.2.12.12.5.1.9
+
+acpmTRPHighTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (523..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event trap number."
+ ::= { acpmTRPEntry 10 }
+ --1.3.6.1.4.1.3052.14.2.12.12.5.1.10
+
+acpmTRPHighClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event class."
+ ::= { acpmTRPEntry 11 }
+ --1.3.6.1.4.1.3052.14.2.12.12.5.1.11
+
+acpmTRPNormalActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return to normal actions."
+ ::= { acpmTRPEntry 12 }
+ --1.3.6.1.4.1.3052.14.2.12.12.5.1.12
+
+acpmTRPNormalTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (523..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return to normal trap number."
+ ::= { acpmTRPEntry 13 }
+ --1.3.6.1.4.1.3052.14.2.12.12.5.1.13
+
+acpmTRPNormalClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return to normal class."
+ ::= { acpmTRPEntry 14 }
+ --1.3.6.1.4.1.3052.14.2.12.12.5.1.14
+
+acpmTRPLowValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event threshold. This is a floating point value."
+ ::= { acpmTRPEntry 15 }
+ --1.3.6.1.4.1.3052.14.2.12.12.5.1.15
+
+acpmTRPLowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event actions."
+ ::= { acpmTRPEntry 16 }
+ --1.3.6.1.4.1.3052.14.2.12.12.5.1.16
+
+acpmTRPLowTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (523..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event trap number."
+ ::= { acpmTRPEntry 17 }
+ --1.3.6.1.4.1.3052.14.2.12.12.5.1.17
+
+acpmTRPLowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event class."
+ ::= { acpmTRPEntry 18 }
+ --1.3.6.1.4.1.3052.14.2.12.12.5.1.18
+
+acpmTRPVLowValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event threshold. This is a floating point value."
+ ::= { acpmTRPEntry 19 }
+ --1.3.6.1.4.1.3052.14.2.12.12.5.1.19
+
+acpmTRPVLowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event actions."
+ ::= { acpmTRPEntry 20 }
+ --1.3.6.1.4.1.3052.14.2.12.12.5.1.20
+
+acpmTRPVLowTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (523..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event trap number."
+ ::= { acpmTRPEntry 21 }
+ --1.3.6.1.4.1.3052.14.2.12.12.5.1.21
+
+acpmTRPVLowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event class."
+ ::= { acpmTRPEntry 22 }
+ --1.3.6.1.4.1.3052.14.2.12.12.5.1.22
+
+acpmTRPSysrepEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "System reporting enable for total real power telemetry."
+ ::= { acpmTRPEntry 23 }
+ --1.3.6.1.4.1.3052.14.2.12.12.5.1.23
+
+acpmTRPSysrepThreshold OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "System reporting threshold for total real power telemetry. This is a
+ floating point value."
+ ::= { acpmTRPEntry 24 }
+ --1.3.6.1.4.1.3052.14.2.12.12.5.1.24
+
+acpmTRPSysrepLimit OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "System reporting limit for total real power telemetry."
+ ::= { acpmTRPEntry 25 }
+ --1.3.6.1.4.1.3052.14.2.12.12.5.1.25
+
+
+acpmDisconnectTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ACPMConfigDisconnect
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table organizes AC power monitor device disconnect event
+ attributes."
+ ::= { acPowerMonitor 6 }
+ --1.3.6.1.4.1.3052.14.2.12.12.6
+
+acpmDisconnectEntry OBJECT-TYPE
+ SYNTAX ACPMConfigDisconnect
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for AC power monitor device disconnect event config table."
+ INDEX { acpmDisconnectIndex }
+ ::= { acpmDisconnectTable 1 }
+ --1.3.6.1.4.1.3052.14.2.12.12.6.1
+
+acpmDisconnectIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..6)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Which AC power monitor in the AC power monitor device disconnect
+ event config table."
+ ::= { acpmDisconnectEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.12.12.6.1.1
+
+acpmDisconnectEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable AC power monitor device disconnect event."
+ ::= { acpmDisconnectEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.12.12.6.1.2
+
+acpmDisconnectActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Actions for disconnect event."
+ ::= { acpmDisconnectEntry 3 }
+ --1.3.6.1.4.1.3052.14.2.12.12.6.1.3
+
+acpmDisconnectTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (524..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Trap number for disconnect event."
+ ::= { acpmDisconnectEntry 4 }
+ --1.3.6.1.4.1.3052.14.2.12.12.6.1.4
+
+acpmDisconnectClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Class for disconnect event."
+ ::= { acpmDisconnectEntry 5 }
+ --1.3.6.1.4.1.3052.14.2.12.12.6.1.5
+
+acpmDisconnectNormalActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Actions for disconnect return to normal event."
+ ::= { acpmDisconnectEntry 6 }
+ --1.3.6.1.4.1.3052.14.2.12.12.6.1.6
+
+acpmDisconnectNormalTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (524..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Trap number for disconnect return to normal event."
+ ::= { acpmDisconnectEntry 7 }
+ --1.3.6.1.4.1.3052.14.2.12.12.6.1.7
+
+acpmDisconnectNormalClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Class for disconnect return to normal event."
+ ::= { acpmDisconnectEntry 8 }
+ --1.3.6.1.4.1.3052.14.2.12.12.6.1.8
+
+acpmTotalPowerFactorTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ACPMConfigTotalPowerFactor
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table organizes AC power monitor device total power factor
+ event attributes."
+ ::= { acPowerMonitor 7 }
+ --1.3.6.1.4.1.3052.14.2.12.12.7
+
+acpmTPFEntry OBJECT-TYPE
+ SYNTAX ACPMConfigTotalPowerFactor
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for AC power monitor device total power factor event config
+ table."
+ INDEX { acpmTPFIndex }
+ ::= { acpmTotalPowerFactorTable 1 }
+ --1.3.6.1.4.1.3052.14.2.12.12.7.1
+
+acpmTPFIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..6)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Which AC power monitor in the AC power monitor device disconnect
+ event config table."
+ ::= { acpmTPFEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.12.12.7.1.1
+
+acpmTPFEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable AC power monitor device disconnect event."
+ ::= { acpmTPFEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.12.12.7.1.2
+
+acpmTPFDeadband OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Deadband (hysteresis)."
+ ::= { acpmTPFEntry 3 }
+ --1.3.6.1.4.1.3052.14.2.12.12.7.1.3
+
+acpmTPFNormalActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Normal actions."
+ ::= { acpmTPFEntry 4 }
+ --1.3.6.1.4.1.3052.14.2.12.12.7.1.4
+
+acpmTPFNormalTrapNum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Normal trap number."
+ ::= { acpmTPFEntry 5 }
+ --1.3.6.1.4.1.3052.14.2.12.12.7.1.5
+
+acpmTPFNormalClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Normal class."
+ ::= { acpmTPFEntry 6 }
+ --1.3.6.1.4.1.3052.14.2.12.12.7.1.6
+
+acpmTPFLowValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low threshold."
+ ::= { acpmTPFEntry 7 }
+ --1.3.6.1.4.1.3052.14.2.12.12.7.1.7
+
+acpmTPFLowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low actions."
+ ::= { acpmTPFEntry 8 }
+ --1.3.6.1.4.1.3052.14.2.12.12.7.1.8
+
+acpmTPFLowTrapNum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low trap number."
+ ::= { acpmTPFEntry 9 }
+ --1.3.6.1.4.1.3052.14.2.12.12.7.1.9
+
+acpmTPFLowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low class."
+ ::= { acpmTPFEntry 10 }
+ --1.3.6.1.4.1.3052.14.2.12.12.7.1.10
+
+acpmTPFVLowValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very Low threshold."
+ ::= { acpmTPFEntry 11 }
+ --1.3.6.1.4.1.3052.14.2.12.12.7.1.11
+
+acpmTPFVLowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very Low actions."
+ ::= { acpmTPFEntry 12 }
+ --1.3.6.1.4.1.3052.14.2.12.12.7.1.12
+
+acpmTPFVLowTrapNum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very Low trap number."
+ ::= { acpmTPFEntry 13 }
+ --1.3.6.1.4.1.3052.14.2.12.12.7.1.13
+
+acpmTPFVLowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very Low class."
+ ::= { acpmTPFEntry 14 }
+ --1.3.6.1.4.1.3052.14.2.12.12.7.1.14
+
+acpmTPFSysrepEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "System reporting enable."
+ ::= { acpmTPFEntry 15 }
+ --1.3.6.1.4.1.3052.14.2.12.12.7.1.15
+
+acpmTPFSysrepThreshold OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "System reporting threshold."
+ ::= { acpmTPFEntry 16 }
+ --1.3.6.1.4.1.3052.14.2.12.12.7.1.16
+
+acpmTPFSysrepLimit OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "System reporting limit."
+ ::= { acpmTPFEntry 17 }
+ --1.3.6.1.4.1.3052.14.2.12.12.7.1.17
+
+
+
+--***************************************************************************************
+--Reset Event Section 2.12.16
+--***************************************************************************************
+
+
+evResetEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable/disable reset event. This event is triggered when the unit
+ finishes booting."
+ ::= { evReset 1 }
+ --1.3.6.1.4.1.3052.14.2.12.16.1
+
+evResetDelay OBJECT-TYPE
+ SYNTAX Integer32 (0..3600)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number of seconds to wait after unit finishes booting before triggering
+ the reset event."
+ ::= { evReset 2 }
+ --1.3.6.1.4.1.3052.14.2.12.16.2
+
+evResetActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Actions for reset event."
+ ::= { evReset 3 }
+ --1.3.6.1.4.1.3052.14.2.12.16.3
+
+evResetMessage OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Message for reset event."
+ ::= { evReset 4 }
+ --1.3.6.1.4.1.3052.14.2.12.16.4
+
+evResetTrapnum OBJECT-TYPE
+ SYNTAX Integer32 (543..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Trap number for reset event."
+ ::= { evReset 5 }
+ --1.3.6.1.4.1.3052.14.2.12.16.5
+
+evResetClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Class (severity) for reset event."
+ ::= { evReset 6 }
+ --1.3.6.1.4.1.3052.14.2.12.16.6
+
+
+--***************************************************************************************
+--Action Section 2.14
+--***************************************************************************************
+
+
+
+actionCallNumberTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ActionCallNumberConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of phone numbers to dial for modem actions"
+ ::= { action 1 }
+ --1.3.6.1.4.1.3052.14.2.14.1
+
+actionCallNumberEntry OBJECT-TYPE
+ SYNTAX ActionCallNumberConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of phone numbers to dial for modem actions"
+ INDEX { actionCallNumberIndex }
+ ::= { actionCallNumberTable 1 }
+ --1.3.6.1.4.1.3052.14.2.14.1.1
+
+actionCallNumberIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..4)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of phone numbers to dial for modem actions"
+ ::= { actionCallNumberEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.14.1.1.1
+
+actionCallNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The number to dial for this action slot"
+ ::= { actionCallNumberEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.14.1.1.2
+
+actionPagerTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ActionPagerConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of pager configurations"
+ ::= { action 2 }
+ --1.3.6.1.4.1.3052.14.2.14.2
+
+actionPagerEntry OBJECT-TYPE
+ SYNTAX ActionPagerConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of pager configurations"
+ INDEX { actionPagerIndex }
+ ::= { actionPagerTable 1 }
+ --1.3.6.1.4.1.3052.14.2.14.2.1
+
+actionPagerIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..4)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "index for table of pager configurations"
+ ::= { actionPagerEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.14.2.1.1
+
+actionPagerType OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "type of this pager configuration"
+ ::= { actionPagerEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.14.2.1.2
+
+actionPagerNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "phone number to dial for this pager configuration"
+ ::= { actionPagerEntry 3 }
+ --1.3.6.1.4.1.3052.14.2.14.2.1.3
+
+actionPagerID OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ID to use for this pager configuration"
+ ::= { actionPagerEntry 4 }
+ --1.3.6.1.4.1.3052.14.2.14.2.1.4
+
+actionPagerMessage OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "message to use for this pager configuration"
+ ::= { actionPagerEntry 5 }
+ --1.3.6.1.4.1.3052.14.2.14.2.1.5
+
+actionPagerPostCalloutDelay OBJECT-TYPE
+ SYNTAX Integer32 (0..255)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Seconds to wait after dialing before sending ID"
+ ::= { actionPagerEntry 6 }
+ --1.3.6.1.4.1.3052.14.2.14.2.1.6
+
+actionPagerPostIDDelay OBJECT-TYPE
+ SYNTAX Integer32 (0..255)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Seconds to wait after sending ID to send message"
+ ::= { actionPagerEntry 7 }
+ --1.3.6.1.4.1.3052.14.2.14.2.1.7
+
+actionSchedEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable action schedule"
+ ::= { actionSched 1 }
+ --1.3.6.1.4.1.3052.14.2.14.3.1
+
+actionSchedBegin OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "action schedule begin time (HH:MM)"
+ ::= { actionSched 2 }
+ --1.3.6.1.4.1.3052.14.2.14.3.2
+
+actionSchedEnd OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "action schedule end time (HH:MM)"
+ ::= { actionSched 3 }
+ --1.3.6.1.4.1.3052.14.2.14.3.3
+
+actionSchedWeekdaysOnly OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF whether the action schedule applies to weekdays only
+ (ON) or all days (OFF)"
+ ::= { actionSched 4 }
+ --1.3.6.1.4.1.3052.14.2.14.3.4
+
+actionAsentriaRequireAck OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF Asentria action requires an ack from the receiver"
+ ::= { actionAsentria 1 }
+ --1.3.6.1.4.1.3052.14.2.14.4.1
+
+actionAsentriaVersion OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "version 1.0 or 1.1"
+ ::= { actionAsentria 2 }
+ --1.3.6.1.4.1.3052.14.2.14.4.2
+
+actionAsentriaTCPPort OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "TCP port used for TCP-based Asentria alarms"
+ ::= { actionAsentria 3 }
+ --1.3.6.1.4.1.3052.14.2.14.4.3
+
+actionHostTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ActionHostConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of network hosts to use for network-based actions"
+ ::= { action 6 }
+ --1.3.6.1.4.1.3052.14.2.14.6
+
+actionHostEntry OBJECT-TYPE
+ SYNTAX ActionHostConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of network hosts to use for network-based
+ actions"
+ INDEX { actionHostIndex }
+ ::= { actionHostTable 1 }
+ --1.3.6.1.4.1.3052.14.2.14.6.1
+
+actionHostIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..6)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of network hosts to use for network-based
+ actions"
+ ::= { actionHostEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.14.6.1.1
+
+actionHost OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Hostname/IP address used as destination for network-based
+ action (e.g., trap)"
+ ::= { actionHostEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.14.6.1.2
+
+actionEmailTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ActionEmailConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of email addresses to use for email actions"
+ ::= { action 7 }
+ --1.3.6.1.4.1.3052.14.2.14.7
+
+actionEmailEntry OBJECT-TYPE
+ SYNTAX ActionEmailConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of email addresses to use for email actions"
+ INDEX { actionEmailIndex }
+ ::= { actionEmailTable 1 }
+ --1.3.6.1.4.1.3052.14.2.14.7.1
+
+actionEmailIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..6)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of email addresses to use for email actions"
+ ::= { actionEmailEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.14.7.1.1
+
+actionEmail OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "email address"
+ ::= { actionEmailEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.14.7.1.2
+
+actionParseError OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "When a user attempts to configure an invalid action setting/
+ object, this object says why it was invalid."
+ ::= { action 8 }
+ --1.3.6.1.4.1.3052.14.2.14.8
+
+--***************************************************************************************
+--System Section 2.16
+--***************************************************************************************
+
+
+sysTimeAutoDST OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF automatically adjust for Daylight Savings Time"
+ ::= { sysTime 1 }
+ --1.3.6.1.4.1.3052.14.2.16.1.1
+
+sysTimeGMTOffset OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Absolute value of offset (hours) from GMT of the timezone"
+ ::= { sysTime 2 }
+ --1.3.6.1.4.1.3052.14.2.16.1.2
+
+sysTimeGMTDirection OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Direction (AHEAD/BEHIND) of timezone relative to GMT"
+ ::= { sysTime 3 }
+ --1.3.6.1.4.1.3052.14.2.16.1.3
+
+
+sysTimeNetEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Network time mode"
+ ::= { sysTimeNet 1 }
+ --1.3.6.1.4.1.3052.14.2.16.1.4.1
+
+sysTimeNetHostTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF NetworkTimeHostConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of hosts to use for network time services"
+ ::= { sysTimeNet 2 }
+ --1.3.6.1.4.1.3052.14.2.16.1.4.2
+
+sysTimeNetHostEntry OBJECT-TYPE
+ SYNTAX NetworkTimeHostConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of hosts to use for network time services"
+ INDEX { sysTimeNetHostIndex }
+ ::= { sysTimeNetHostTable 1 }
+ --1.3.6.1.4.1.3052.14.2.16.1.4.2.1
+
+sysTimeNetHostIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..6)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of hosts to use for network time services"
+ ::= { sysTimeNetHostEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.16.1.4.2.1.1
+
+sysTimeNetHost OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "host to use for network time services"
+ ::= { sysTimeNetHostEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.16.1.4.2.1.2
+
+sysPTTimeout OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Timeout (minutes) of inactivity after which a pass-through
+ session is terminated (0 means it never terminates)"
+ ::= { sysPT 1 }
+ --1.3.6.1.4.1.3052.14.2.16.2.1
+
+sysPTEndPause OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "number of 16ths of a second between escape characters
+ received on pass-through origin IO handle that are reuired
+ for the escape characters to register as pass-through escape
+ characters in the pass-through escape sequence. Set to 0 to
+ make the escape character register as part of the pass-
+ through escape sequence without requiring a pause."
+ ::= { sysPT 2 }
+ --1.3.6.1.4.1.3052.14.2.16.2.2
+
+sysPTJoinable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable joinable pass-through sessions."
+ ::= { sysPT 3 }
+ --1.3.6.1.4.1.3052.14.2.16.2.3
+
+sysMTU OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Maximum transfer unit for ethernet interfaces"
+ ::= { sys 3 }
+ --1.3.6.1.4.1.3052.14.2.16.3
+
+sysAnswerString OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "String displayed upon login"
+ ::= { sys 4 }
+ --1.3.6.1.4.1.3052.14.2.16.4
+
+sysEventFileID OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ID string for events file"
+ ::= { sys 6 }
+ --1.3.6.1.4.1.3052.14.2.16.6
+
+sysEscapeCharacter OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Decimal ASCII code of the system escape character"
+ ::= { sys 7 }
+ --1.3.6.1.4.1.3052.14.2.16.7
+
+sysTimeStampTimeFormat OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Format of time stamp: HH:MM,HH:MM:SS,BLANK"
+ ::= { sysTimeStamp 1 }
+ --1.3.6.1.4.1.3052.14.2.16.8.1
+
+sysTimeStampDateFormat OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Format of date stamp: MM/DD,MM/DD/YY,MM/DD/YYYY,BLANK"
+ ::= { sysTimeStamp 2 }
+ --1.3.6.1.4.1.3052.14.2.16.8.2
+
+sysTimeStampSpaceAfter OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF Inlude a space after timestamp"
+ ::= { sysTimeStamp 3 }
+ --1.3.6.1.4.1.3052.14.2.16.8.3
+
+sysLogMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Syslog mode: disabled, emit UDP (REMOTE), save in a
+ rotating file set (FILE), or emit on a listening socket
+ (SERVER)"
+ ::= { sysLog 1 }
+ --1.3.6.1.4.1.3052.14.2.16.9.1
+
+sysLoghost OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Syslog host: destination machine when syslog mode is REMOTE"
+ ::= { sysLog 2 }
+ --1.3.6.1.4.1.3052.14.2.16.9.2
+
+sysLogFilter OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "String describing what functions place data in the syslog"
+ ::= { sysLog 3 }
+ --1.3.6.1.4.1.3052.14.2.16.9.3
+
+sysLogFileSize OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Size (in KB) of syslog files (when syslog mode is SERVER or
+ FILE)"
+ ::= { sysLog 4 }
+ --1.3.6.1.4.1.3052.14.2.16.9.4
+
+sysLogFileCount OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number of files in syslog file set (when syslog mode is
+ SERVER or FILE)"
+ ::= { sysLog 5 }
+ --1.3.6.1.4.1.3052.14.2.16.9.5
+
+sysLogListenPort OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "TCP port on which the unit listens for a connection on
+ which syslog data is dumped (when syslog mode is SERVER)"
+ ::= { sysLog 6 }
+ --1.3.6.1.4.1.3052.14.2.16.9.6
+
+sysCRDBCapacity OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Capacity of Call Record Database (in KB)"
+ ::= { sysCRDB 1 }
+ --1.3.6.1.4.1.3052.14.2.16.10.1
+
+sysCRDBPercentFull OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Percent of the CRDB used"
+ ::= { sysCRDB 2 }
+ --1.3.6.1.4.1.3052.14.2.16.10.2
+
+
+sysCRDBFileIDTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CRDBFileIDConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of CRDB file IDs"
+ ::= { sysCRDB 3 }
+ --1.3.6.1.4.1.3052.14.2.16.10.3
+
+sysCRDBFileIDEntry OBJECT-TYPE
+ SYNTAX CRDBFileIDConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of CRDB file IDs"
+ INDEX { sysCRDBFileIDIndex }
+ ::= { sysCRDBFileIDTable 1 }
+ --1.3.6.1.4.1.3052.14.2.16.10.3.1
+
+sysCRDBFileIDIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..16)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of CRDB file IDs"
+ ::= { sysCRDBFileIDEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.16.10.3.1.1
+
+sysCRDBFileID OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ID of CRDB file for this port-associated file x"
+ ::= { sysCRDBFileIDEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.16.10.3.1.2
+
+sysCRDBFileEnforceMinTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CRDBFileEnforceMinConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of CRDB file minimum size enforcement settings"
+ ::= { sysCRDB 4 }
+ --1.3.6.1.4.1.3052.14.2.16.10.4
+
+sysCRDBFileEnforceMinEntry OBJECT-TYPE
+ SYNTAX CRDBFileEnforceMinConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of CRDB file minimum size enforcement
+ settings"
+ INDEX { sysCRDBFileEnforceMinIndex }
+ ::= { sysCRDBFileEnforceMinTable 1 }
+ --1.3.6.1.4.1.3052.14.2.16.10.4.1
+
+sysCRDBFileEnforceMinIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..24)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of CRDB file minimum size enforcement
+ settings"
+ ::= { sysCRDBFileEnforceMinEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.16.10.4.1.1
+
+sysCRDBFileEnforceMin OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF: enforce minimum size for this CRDB file x"
+ ::= { sysCRDBFileEnforceMinEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.16.10.4.1.2
+
+sysCharMask OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Character mask used for ignoring certain characters on
+ serial ports when assembling data records (when port mode is
+ ASCII)"
+ ::= { sys 11 }
+ --1.3.6.1.4.1.3052.14.2.16.11
+
+sysPrompt OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Prompt to use in a commnand session"
+ ::= { sys 12 }
+ --1.3.6.1.4.1.3052.14.2.16.12
+
+sysBootStatus OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "String describing the boot status of the unit (Booted OK/
+ still booting"
+ ::= { sys 13 }
+ --1.3.6.1.4.1.3052.14.2.16.13
+
+sysLocLatitude OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Latitude portion of geographic coordinates as string"
+ ::= { sysLoc 1 }
+ --1.3.6.1.4.1.3052.14.2.16.14.1
+
+sysLocLongitude OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Longitude portion of geographic coordinates as string"
+ ::= { sysLoc 2 }
+ --1.3.6.1.4.1.3052.14.2.16.14.2
+
+sysLocXOffset OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "X-offset portion of geographic coordinates as string"
+ ::= { sysLoc 3 }
+ --1.3.6.1.4.1.3052.14.2.16.14.3
+
+sysLocYOffset OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Y offset portion of geographic coordinates as string"
+ ::= { sysLoc 4 }
+ --1.3.6.1.4.1.3052.14.2.16.14.4
+
+sysLocAngle OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Angle portion of geographic coordinates as string"
+ ::= { sysLoc 5 }
+ --1.3.6.1.4.1.3052.14.2.16.14.5
+
+sysLocAltitude OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Altitude portion of geographic coordinates as string"
+ ::= { sysLoc 6 }
+ --1.3.6.1.4.1.3052.14.2.16.14.6
+
+sysAMManufacturer OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Device manufacturer"
+ ::= { sysAssetMgmt 1 }
+ --1.3.6.1.4.1.3052.14.2.16.15.1
+
+sysAMProduct OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Device product description (i.e., model or model number)"
+ ::= { sysAssetMgmt 2 }
+ --1.3.6.1.4.1.3052.14.2.16.15.2
+
+sysAMSerialNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Manufacturer serial number for device"
+ ::= { sysAssetMgmt 3 }
+ --1.3.6.1.4.1.3052.14.2.16.15.3
+
+sysAMHardwareOptions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Hardware options currently installed on device"
+ ::= { sysAssetMgmt 4 }
+ --1.3.6.1.4.1.3052.14.2.16.15.4
+
+sysAMSoftwareVersion OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Currently-running software version on device"
+ ::= { sysAssetMgmt 5 }
+ --1.3.6.1.4.1.3052.14.2.16.15.5
+
+sysAMSiteName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Site Name of device (user definable, also known as the
+ siteName object under the productIds branch."
+ ::= { sysAssetMgmt 6 }
+ --1.3.6.1.4.1.3052.14.2.16.15.6
+
+
+--***************************************************************************************
+--Sys File Transfer Section 2.16.17
+--***************************************************************************************
+
+sysFileTransferStatus OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Start/cancel file transfer, or check transfer status. To start, set this object
+ to 'start'. To cancel, set this object to 'cancel'. To check status, get the
+ object"
+ ::= { sysFileTransfer 1 }
+ --1.3.6.1.4.1.3052.14.2.16.17.1
+
+sysFileTransferURL OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "URL (describing protocol, host, directory, and file) on which file transfer
+ function operates."
+ ::= { sysFileTransfer 2 }
+ --1.3.6.1.4.1.3052.14.2.16.17.2
+
+sysFileTransferUsername OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Username for user account at the resource specified by sysFileTransferURL."
+ ::= { sysFileTransfer 3 }
+ --1.3.6.1.4.1.3052.14.2.16.17.3
+
+sysFileTransferPassword OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Password for user account at the resource specified by sysFileTransferURL."
+ ::= { sysFileTransfer 4 }
+ --1.3.6.1.4.1.3052.14.2.16.17.4
+
+--***************************************************************************************
+--Sys Update Section 2.16.18
+--***************************************************************************************
+
+sysUpdateStatus OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Check time/result of last update attempt."
+ ::= { sysUpdate 1 }
+ --1.3.6.1.4.1.3052.14.2.16.18.1
+
+
+--***************************************************************************************
+--Audit Log Section 2.17
+--***************************************************************************************
+
+auditLogEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable audit log"
+ ::= { auditLog 1 }
+ --1.3.6.1.4.1.3052.14.2.17.1
+
+auditLogStoreResets OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF audit log stores when the unit resets"
+ ::= { auditLog 2 }
+ --1.3.6.1.4.1.3052.14.2.17.1
+
+auditLogStoreCommands OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF audit log stores commands entered in a command
+ session"
+ ::= { auditLog 3 }
+ --1.3.6.1.4.1.3052.14.2.17.1
+
+auditLogStoreOutputs OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF audit log stores output (relay output and power output)
+ activity"
+ ::= { auditLog 4 }
+ --1.3.6.1.4.1.3052.14.2.17.1
+
+auditLogStoreAlarmActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF audit log stores action delivery activity"
+ ::= { auditLog 5 }
+ --1.3.6.1.4.1.3052.14.2.17.1
+
+auditLogStorePwdFailures OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF audit log stores when user was denied login"
+ ::= { auditLog 6 }
+ --1.3.6.1.4.1.3052.14.2.17.1
+
+auditLogStoreLogins OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF audit log stores when a user was allowed login"
+ ::= { auditLog 7 }
+ --1.3.6.1.4.1.3052.14.2.17.1
+
+auditLogStoreSHSK OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF audit log stores serial handshaking status
+ (regardless of serial handshaking event)"
+ ::= { auditLog 8 }
+ --1.3.6.1.4.1.3052.14.2.17.1
+
+auditLogStorePassthrough OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF audit log stores pass-through activity"
+ ::= { auditLog 9 }
+ --1.3.6.1.4.1.3052.14.2.17.1
+
+auditLogStoreInactivity OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF audit log stores when sessions expire due to
+ inactivity"
+ ::= { auditLog 10 }
+ --1.3.6.1.4.1.3052.14.2.17.1
+
+auditLogStorePolling OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF audit log stores CRDB polling activity"
+ ::= { auditLog 11 }
+ --1.3.6.1.4.1.3052.14.2.17.1
+
+auditLogMaxSize OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Maximum size (in KB) of audit log"
+ ::= { auditLog 12 }
+ --1.3.6.1.4.1.3052.14.2.17.1
+
+--***************************************************************************************
+--Scripting Section 2.17
+--***************************************************************************************
+
+scrGlobalEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable scripting"
+ ::= { scripting 1 }
+ --1.3.6.1.4.1.3052.14.2.18.1
+
+scrDTRCtrlPortEnableTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ScriptingDTRCtrlPortEnableConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of DTR control port enables"
+ ::= { scripting 2 }
+ --1.3.6.1.4.1.3052.14.2.18.2
+
+scrDTRCtrlPortEnableEntry OBJECT-TYPE
+ SYNTAX ScriptingDTRCtrlPortEnableConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of DTR control port enables"
+ INDEX { scrDTRCtrlPortEnableIndex }
+ ::= { scrDTRCtrlPortEnableTable 1 }
+ --1.3.6.1.4.1.3052.14.2.18.2.1
+
+scrDTRCtrlPortEnableIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..16)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of DTR control port enables"
+ ::= { scrDTRCtrlPortEnableEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.18.2.1.1
+
+scrDTRCtrlPortEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable DTR control of scripting for this port"
+ ::= { scrDTRCtrlPortEnableEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.18.2.1.2
+
+
+scrTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ScriptingConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of scripts"
+ ::= { scripting 3 }
+ --1.3.6.1.4.1.3052.14.2.18.3
+
+scrEntry OBJECT-TYPE
+ SYNTAX ScriptingConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of scripts"
+ INDEX { scrIndex }
+ ::= { scrTable 1 }
+ --1.3.6.1.4.1.3052.14.2.18.3.1
+
+scrIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..20)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of scripts"
+ ::= { scrEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.18.3.1.1
+
+scrEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable this script"
+ ::= { scrEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.18.3.1.2
+
+scrName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Name of this script"
+ ::= { scrEntry 3 }
+ --1.3.6.1.4.1.3052.14.2.18.3.1.3
+
+scrFilename OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Filename for this script"
+ ::= { scrEntry 4 }
+ --1.3.6.1.4.1.3052.14.2.18.3.1.4
+
+scrRunAlways OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF: this script always runs"
+ ::= { scrEntry 5 }
+ --1.3.6.1.4.1.3052.14.2.18.3.1.5
+
+scrRunAtStartup OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF: this script runs at startup"
+ ::= { scrEntry 6 }
+ --1.3.6.1.4.1.3052.14.2.18.3.1.6
+
+scrRunScheduled OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF: this script runs at a certain time of day"
+ ::= { scrEntry 7 }
+ --1.3.6.1.4.1.3052.14.2.18.3.1.7
+
+scrScheduleTime OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time of day (HH:MM) this script is scheduled to run"
+ ::= { scrEntry 8 }
+ --1.3.6.1.4.1.3052.14.2.18.3.1.8
+
+scrArguments OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Arguments for this script"
+ ::= { scrEntry 9 }
+ --1.3.6.1.4.1.3052.14.2.18.3.1.9
+
+scrRepeatInterval OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "How often this script runs (minutes)"
+ ::= { scrEntry 10 }
+ --1.3.6.1.4.1.3052.14.2.18.3.1.10
+
+scrVolatileStringTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ScriptingVolatileString
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of volatile string settings for use in
+ scripts."
+ ::= { scripting 4 }
+ --1.3.6.1.4.1.3052.14.2.18.4
+
+scrVolatileStringEntry OBJECT-TYPE
+ SYNTAX ScriptingVolatileString
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of volatile script string
+ settings"
+ INDEX { scrVolatileStringIndex }
+ ::= { scrVolatileStringTable 1 }
+ --1.3.6.1.4.1.3052.14.2.18.4.1
+
+scrVolatileStringIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..50)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of volatile script string
+ settings"
+ ::= { scrVolatileStringEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.18.4.1.1
+
+scrVolatileString OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Volatile string for use in scripts. Use this
+ object to cache frequently-changing string values
+ or string values that do not need to persist
+ through reset. This object corresponds to the
+ scripting.vstring[] setting key branch; use those
+ keys in scripts and you can view or change their
+ values with this object."
+ ::= { scrVolatileStringEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.18.4.1.2
+
+scrVolatileIntTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ScriptingVolatileInt
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of volatile integer settings for use in
+ scripts."
+ ::= { scripting 5 }
+ --1.3.6.1.4.1.3052.14.2.18.5
+
+scrVolatileIntEntry OBJECT-TYPE
+ SYNTAX ScriptingVolatileInt
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of volatile script integer
+ settings"
+ INDEX { scrVolatileIntIndex }
+ ::= { scrVolatileIntTable 1 }
+ --1.3.6.1.4.1.3052.14.2.18.5.1
+
+scrVolatileIntIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..50)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of volatile script integer
+ settings"
+ ::= { scrVolatileIntEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.18.5.1.1
+
+scrVolatileInt OBJECT-TYPE
+ SYNTAX Integer32 (0..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Volatile integer for use in scripts. Use this
+ object to cache frequently-changing integer values
+ or integer values that do not need to persist
+ through reset. This object corresponds to the
+ scripting.vint[] setting key branch; use those
+ keys in scripts and you can view or change their
+ values with this object."
+ ::= { scrVolatileIntEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.18.5.1.2
+
+scrNonVolatileStringTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ScriptingNonVolatileString
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of non-volatile string settings for use in
+ scripts."
+ ::= { scripting 6 }
+ --1.3.6.1.4.1.3052.14.2.18.6
+
+scrNonVolatileStringEntry OBJECT-TYPE
+ SYNTAX ScriptingNonVolatileString
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of non-volatile script string
+ settings"
+ INDEX { scrNonVolatileStringIndex }
+ ::= { scrNonVolatileStringTable 1 }
+ --1.3.6.1.4.1.3052.14.2.18.6.1
+
+scrNonVolatileStringIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..50)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of non-volatile script string
+ settings"
+ ::= { scrNonVolatileStringEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.18.6.1.1
+
+scrNonVolatileString OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Non-volatile string for use in scripts. Use this
+ object to store values that need to persist
+ through reset. This object corresponds to the
+ scripting.nvstring[] setting key branch; use those
+ keys in scripts and you can view or change their
+ values with this object. Note: to store frequently-
+ changing integers, use the scrVolatileString object,
+ otherwise your scripts may cause unnecessary wear of
+ the non-volatile storage medium on the unit."
+ ::= { scrNonVolatileStringEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.18.6.1.2
+
+scrNonVolatileIntTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ScriptingNonVolatileInt
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of non-volatile integer settings for use in
+ scripts."
+ ::= { scripting 7 }
+ --1.3.6.1.4.1.3052.14.2.18.7
+
+scrNonVolatileIntEntry OBJECT-TYPE
+ SYNTAX ScriptingNonVolatileInt
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of non-volatile script integer
+ settings"
+ INDEX { scrNonVolatileIntIndex }
+ ::= { scrNonVolatileIntTable 1 }
+ --1.3.6.1.4.1.3052.14.2.18.7.1
+
+scrNonVolatileIntIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..50)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of non-volatile script integer
+ settings"
+ ::= { scrNonVolatileIntEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.18.7.1.1
+
+scrNonVolatileInt OBJECT-TYPE
+ SYNTAX Integer32 (0..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Non-volatile integer for use in scripts. Use this
+ object to store integer values that need to persist
+ through reset. This object corresponds to the
+ scripting.nvint[] setting key branch; use those
+ keys in scripts and you can view or change their
+ values with this object. Note: to store frequently-
+ changing integers, use the scrVolatileInt object,
+ otherwise your scripts may cause unnecessary wear of
+ the non-volatile storage medium on the unit."
+ ::= { scrNonVolatileIntEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.18.7.1.2
+
+--***************************************************************************************
+--Product IDs Section 3
+--***************************************************************************************
+
+siteName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Site Name string; Max 40 characters."
+ ::= { productIds 1 }
+ --1.3.6.1.4.1.3052.14.3.1
+
+thisProduct OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This is a factory configured string for the
+ product name."
+ ::= { productIds 2 }
+ --1.3.6.1.4.1.3052.14.3.2
+
+stockTrapString OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The message defined for the event that triggers a trap."
+ ::= { productIds 3 }
+ --1.3.6.1.4.1.3052.14.3.3
+
+trapEventTypeNumber OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The user-defined trap variable for the type of
+ event that happened. Definitions:
+ 4 Scheduled
+ 7 Serial Handshaking Low
+ 8 Serial Handshaking High
+ 10 Contact Closure Active
+ 11 Contact Closure Inactive
+ 12 Temperature High
+ 13 Temperature Very High
+ 14 Temperature Low
+ 15 Temperature Very Low
+ 16 Temperature Return to Normal
+ 17 Humidity High
+ 18 Humidity Very High
+ 19 Humidity Low
+ 20 Humidity Very Low
+ 21 Humidity Return to Normal
+ 26 Analog High
+ 27 Analog Very High
+ 28 Analog Low
+ 29 Analog Very Low
+ 30 Analog Normal
+ 40 EventSensor Unresponsive
+ 41 Custom
+ 42 CPE Down
+ 44 CPE Normal
+ 47 Power Distribution
+ 49 Fuel Sensor Disconnect
+ 50 Fuel Sensor Disconnect Return to Normal
+ 52 AISG Device Alarm
+ 53 AISG Device Alarm Return to Normal
+ 54 AISG Device Unresponsive
+ 55 AISG Device Unresponsive Return to Normal
+ 56 Fuel Sensor
+ 57 AC Power Monitor Average Voltage Very Low
+ 58 AC Power Monitor Average Voltage Low
+ 59 AC Power Monitor Average Voltage Return to Normal
+ 60 AC Power Monitor Average Voltage High
+ 61 AC Power Monitor Average Voltage Very High
+ 62 AC Power Monitor Average Current Very Low
+ 63 AC Power Monitor Average Current Low
+ 64 AC Power Monitor Average Current Return to Normal
+ 65 AC Power Monitor Average Current High
+ 66 AC Power Monitor Average Current Very High
+ 67 AC Power Monitor Frequency Very Low
+ 68 AC Power Monitor Frequency Low
+ 69 AC Power Monitor Frequency Return to Normal
+ 70 AC Power Monitor Frequency High
+ 71 AC Power Monitor Frequency Very High
+ 72 AC Power Monitor Total Real Power Very Low
+ 73 AC Power Monitor Total Real Power Low
+ 74 AC Power Monitor Total Real Power Return to Normal
+ 75 AC Power Monitor Total Real Power High
+ 76 AC Power Monitor Total Real Power Very High
+ 77 AC Power Monitor Disconnect
+ 78 AC Power Monitor Disconnect Return to Normal
+ 79 Load Shedding Started
+ 80 Load Shedding Ended
+ 81 Fuel Sensor Volume Sudden Change
+ 82 Fuel Sensor Volume Slow Change
+ 83 CPE Down Reminder
+ 84 AC Power Monitor Total Power Factor Very Low
+ 85 AC Power Monitor Total Power Factor Low
+ 86 AC Power Monitor Total Power Factor Return to Normal
+ 100 Contact Closure Active Reminder
+ 101 Temperature High Reminder
+ 102 Temperature High Very Reminder
+ 103 Temperature Low Reminder
+ 104 Temperature Very Low Reminder
+ 105 Humidity High Reminder
+ 106 Humidity Very High Reminder
+ 107 Humidity Low Reminder
+ 108 Humidity Very Low Reminder
+ 109 Analog High Reminder
+ 110 Analog Very High Reminder
+ 111 Analog Low Reminder
+ 112 Analog Very Low Reminder
+ 130 Relay Output Active
+ 131 Relay Output Inactive
+ 132 Power Output On
+ 133 Power Output Off
+ 164 Reset
+ 166 Fuel Sensor Levels Auto Adjust
+ "
+ ::= { productIds 4 }
+ --1.3.6.1.4.1.3052.14.3.4
+
+trapEventTypeName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The user-defined trap variable for the string
+ corresponding to the event type."
+ ::= { productIds 5 }
+ --1.3.6.1.4.1.3052.14.3.5
+
+trapIncludedValue OBJECT-TYPE
+ SYNTAX Integer32 (-2147483648..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The user-defined trap variable for the generic
+ included value."
+ ::= { productIds 6 }
+ --1.3.6.1.4.1.3052.14.3.6
+
+trapIncludedString OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The user-defined trap variable for the generic
+ included string."
+ ::= { productIds 7 }
+ --1.3.6.1.4.1.3052.14.3.7
+
+trapTypeString OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The cause of the trap, added for DL880 compatibility."
+ ::= { productIds 8 }
+ --1.3.6.1.4.1.3052.14.3.8
+
+trapEventClassNumber OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The user-defined trap variable for the configurable
+ class number associated with the triggering event."
+ ::= { productIds 9 }
+ --1.3.6.1.4.1.3052.14.3.9
+
+trapEventClassName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The user-defined trap variable for the configurable
+ class name associated with the class number."
+ ::= { productIds 10 }
+ --1.3.6.1.4.1.3052.14.3.10
+
+
+--***************************************************************************************
+--Product IDs Section 3
+--***************************************************************************************
+
+keyInterface OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object represents a setting key interface. When
+ setting this object, the value to set is the 'sk' command
+ you would enter on the command line (without the 'sk'). To
+ get the result of the operation, read this object after you
+ write it.
+
+ For example, to configure EventSensor 1 contact closure 34
+ event actions to be an SNMP InformRequest to host foo, set
+ this object to:
+ 'event.sensor[1].cc[34].eventactions=inform(foo)'. The SNMP
+ response is the result of the operation: if setting that key
+ to that value was a success then the SNMP response will be a
+ success and the response value will be what you had set. If
+ you subsequently read this object then you will see a
+ message 'OK: ...'.
+
+ If setting that key to that value failed then the SNMP
+ response will be a failure (a badValue response). If you
+ subsequently read this object then the value returned is the
+ reason that setting that key to that value failed.
+
+ For another example, to read user 3's pass-through access
+ for port 7, set this object to:
+ 'sec.user[3].port[7].ptaccess'. The SNMP response is the
+ result of the operation: if reading that key is a success
+ then the SNMP response will be a success and the response
+ value will be what you had SET (i.e., the opertion of
+ reading a key, which is just the key itself with no '='
+ operator, and this is not the key value you want to read).
+ If you subsequently read this object then the value
+ returned is the value of the key you want to read.
+
+ If reading that key failed (e.g., if the key is invalid)
+ then the SNMP response to your SNMP set operation (the
+ value you set being the invalid key to read) will be a
+ failure (a badValue response). If you subsequently read
+ this object then the value returned is the reason that
+ reading that key failed (i.e., 'invalid key')."
+ ::= { s571 4 }
+ --1.3.6.1.4.1.3052.14.4
+
+
+--***************************************************************************************
+--TABLE DEFINITIONS
+--***************************************************************************************
+
+ESPointConfigTemp ::=
+ SEQUENCE {
+ espcTempIndexES
+ Integer32,
+ espcTempIndexPoint
+ Integer32,
+ espcTempEnable
+ DisplayString,
+ espcTempScale
+ DisplayString,
+ espcTempDeadband
+ DisplayString,
+ espcTempVHighTemp
+ DisplayString,
+ espcTempVHighActions
+ DisplayString,
+ espcTempVHighTrapnum
+ Integer32,
+ espcTempVHighClass
+ DisplayString,
+ espcTempHighTemp
+ DisplayString,
+ espcTempHighActions
+ DisplayString,
+ espcTempHighTrapnum
+ Integer32,
+ espcTempHighClass
+ DisplayString,
+ espcTempNormalActions
+ DisplayString,
+ espcTempNormalTrapnum
+ Integer32,
+ espcTempNormalClass
+ DisplayString,
+ espcTempLowTemp
+ DisplayString,
+ espcTempLowActions
+ DisplayString,
+ espcTempLowTrapnum
+ Integer32,
+ espcTempLowClass
+ DisplayString,
+ espcTempVLowTemp
+ DisplayString,
+ espcTempVLowActions
+ DisplayString,
+ espcTempVLowTrapnum
+ Integer32,
+ espcTempVLowClass
+ DisplayString
+}
+
+
+ESPointConfigCC ::=
+ SEQUENCE {
+ espcCCIndexES
+ Integer32,
+ espcCCIndexPoint
+ Integer32,
+ espcCCEnable
+ DisplayString,
+ espcCCName
+ DisplayString,
+ espcCCEventState
+ DisplayString,
+ espcCCThreshold
+ Integer32,
+ espcCCEventActions
+ DisplayString,
+ espcCCEventTrapnum
+ Integer32,
+ espcCCEventClass
+ DisplayString,
+ espcCCNormalActions
+ DisplayString,
+ espcCCNormalTrapnum
+ Integer32,
+ espcCCNormalClass
+ DisplayString,
+ espcCCAlarmAlias
+ DisplayString,
+ espcCCNormalAlias
+ DisplayString,
+ espcCCNormalThreshold
+ Integer32,
+ espcCCOverrideGlobalReminder
+ DisplayString,
+ espcCCReminderInterval
+ Integer32
+}
+
+ESPointConfigHumid ::=
+ SEQUENCE {
+ espcHumidIndexES
+ Integer32,
+ espcHumidIndexPoint
+ Integer32,
+ espcHumidEnable
+ DisplayString,
+ espcHumidDeadband
+ Integer32,
+ espcHumidVHighHumid
+ Integer32,
+ espcHumidVHighActions
+ DisplayString,
+ espcHumidVHighTrapnum
+ Integer32,
+ espcHumidVHighClass
+ DisplayString,
+ espcHumidHighHumid
+ Integer32,
+ espcHumidHighActions
+ DisplayString,
+ espcHumidHighTrapnum
+ Integer32,
+ espcHumidHighClass
+ DisplayString,
+ espcHumidNormalActions
+ DisplayString,
+ espcHumidNormalTrapnum
+ Integer32,
+ espcHumidNormalClass
+ DisplayString,
+ espcHumidLowHumid
+ Integer32,
+ espcHumidLowActions
+ DisplayString,
+ espcHumidLowTrapnum
+ Integer32,
+ espcHumidLowClass
+ DisplayString,
+ espcHumidVLowHumid
+ Integer32,
+ espcHumidVLowActions
+ DisplayString,
+ espcHumidVLowTrapnum
+ Integer32,
+ espcHumidVLowClass
+ DisplayString
+}
+
+ESPointConfigAnalogInput ::=
+ SEQUENCE {
+ espcAIIndexES
+ Integer32,
+ espcAIIndexPoint
+ Integer32,
+ espcAIEnable
+ DisplayString,
+ espcAIDeadband
+ DisplayString,
+ espcAIVhighValue
+ DisplayString,
+ espcAIVhighActions
+ DisplayString,
+ espcAIVhighTrapnum
+ Integer32,
+ espcAIVhighClass
+ DisplayString,
+ espcAIHighValue
+ DisplayString,
+ espcAIHighActions
+ DisplayString,
+ espcAIHighTrapnum
+ Integer32,
+ espcAIHighClass
+ DisplayString,
+ espcAINormalActions
+ DisplayString,
+ espcAINormalTrapnum
+ Integer32,
+ espcAINormalClass
+ DisplayString,
+ espcAILowValue
+ DisplayString,
+ espcAILowActions
+ DisplayString,
+ espcAILowTrapnum
+ Integer32,
+ espcAILowClass
+ DisplayString,
+ espcAIVlowValue
+ DisplayString,
+ espcAIVlowActions
+ DisplayString,
+ espcAIVlowTrapnum
+ Integer32,
+ espcAIVlowClass
+ DisplayString,
+ espcAIConvUnitName
+ DisplayString,
+ espcAIConvHighValue
+ DisplayString,
+ espcAIConvHighUnit
+ DisplayString,
+ espcAIConvLowValue
+ DisplayString,
+ espcAIConvLowUnit
+ DisplayString,
+ espcAIDisplayFormat
+ DisplayString
+}
+
+
+ActionCallNumberConfig ::=
+ SEQUENCE {
+ actionCallNumberIndex
+ Integer32,
+ actionCallNumber
+ DisplayString
+
+}
+
+ActionPagerConfig ::=
+ SEQUENCE {
+ actionPagerIndex
+ Integer32,
+ actionPagerType
+ DisplayString,
+ actionPagerNumber
+ DisplayString,
+ actionPagerID
+ DisplayString,
+ actionPagerMessage
+ DisplayString,
+ actionPagerPostCalloutDelay
+ Integer32,
+ actionPagerPostIDDelay
+ Integer32
+}
+
+ESPointConfigOutput ::=
+ SEQUENCE {
+ espcOutputIndexES
+ Integer32,
+ espcOutputIndexPoint
+ Integer32,
+ espcOutputEnable
+ DisplayString,
+ espcOutputActiveState
+ DisplayString,
+ espcOutputType
+ DisplayString,
+ espcOutputAliasValue
+ DisplayString,
+ espcOutputAliasColor
+ DisplayString,
+ espcOutputActiveAlias
+ DisplayString,
+ espcOutputActiveColor
+ DisplayString,
+ espcOutputActiveActions
+ DisplayString,
+ espcOutputActiveTrapnum
+ Integer32,
+ espcOutputActiveClass
+ DisplayString,
+ espcOutputInactiveAlias
+ DisplayString,
+ espcOutputInactiveColor
+ DisplayString,
+ espcOutputInactiveActions
+ DisplayString,
+ espcOutputInactiveTrapnum
+ Integer32,
+ espcOutputInactiveClass
+ DisplayString
+}
+
+EventClassConfig ::=
+ SEQUENCE {
+ evClassNameIndex
+ Integer32,
+ evClassName
+ DisplayString
+}
+
+RTSFileConfig ::=
+ SEQUENCE {
+ rtsFileIndex
+ Integer32,
+ rtsFileMode
+ DisplayString,
+ rtsFileShowAnswer
+ DisplayString,
+ rtsFileReqXON
+ DisplayString,
+ rtsFileTimeout
+ Integer32,
+ rtsFileEmptyClose
+ DisplayString,
+ rtsFilePushHost
+ DisplayString,
+ rtsFilePushPort
+ Integer32,
+ rtsFilePushRetryTimer
+ Integer32
+}
+
+
+ModemCLIDLogConfig ::=
+ SEQUENCE {
+ modemCLIDLogIndex
+ Integer32,
+ modemCLIDLogNumber
+ DisplayString
+}
+
+
+PowerDistribOutputCurrent ::=
+ SEQUENCE {
+ pdOutputCurrentIndex
+ Integer32,
+ pdOutputCurrentInEventState
+ DisplayString,
+ pdOutputCurrentValue
+ Integer32,
+ pdOutputCurrentValueStr
+ DisplayString,
+ pdOutputCurrentDeadband
+ Integer32,
+ pdOutputCurrentVHighCurrent
+ Integer32,
+ pdOutputCurrentHighCurrent
+ Integer32,
+ pdOutputCurrentLowCurrent
+ Integer32,
+ pdOutputCurrentVLowCurrent
+ Integer32
+}
+
+PowerDistribOutputFuse ::=
+ SEQUENCE {
+ pdOutputFuseIndex
+ Integer32,
+ pdOutputFuseInEventState
+ DisplayString,
+ pdOutputFuseValueStr
+ DisplayString
+}
+
+PowerDistribNextGen ::=
+ SEQUENCE {
+ pdnIndexPD
+ Integer32,
+ pdnIndexOutput
+ Integer32,
+ pdnConfig
+ DisplayString,
+ pdnMainCurrentInEventState
+ DisplayString,
+ pdnMainCurrentValue
+ Integer32,
+ pdnMainCurrentValueStr
+ DisplayString,
+ pdnMainCurrentDeadband
+ Integer32,
+ pdnMainCurrentVHighCurrent
+ Integer32,
+ pdnMainCurrentHighCurrent
+ Integer32,
+ pdnMainCurrentLowCurrent
+ Integer32,
+ pdnMainCurrentVLowCurrent
+ Integer32,
+ pdnMainVoltageInEventState
+ DisplayString,
+ pdnMainVoltageValue
+ Integer32,
+ pdnMainVoltageValueStr
+ DisplayString,
+ pdnMainVoltageDeadband
+ Integer32,
+ pdnMainVoltageVHighVoltage
+ Integer32,
+ pdnMainVoltageHighVoltage
+ Integer32,
+ pdnMainVoltageLowVoltage
+ Integer32,
+ pdnMainVoltageVLowVoltage
+ Integer32,
+ pdnMainPowerValue
+ Integer32,
+ pdnMainPowerValueStr
+ DisplayString,
+ pdnOutputCurrentInEventState
+ DisplayString,
+ pdnOutputCurrentValue
+ Integer32,
+ pdnOutputCurrentValueStr
+ DisplayString,
+ pdnOutputCurrentDeadband
+ Integer32,
+ pdnOutputCurrentVHighCurrent
+ Integer32,
+ pdnOutputCurrentHighCurrent
+ Integer32,
+ pdnOutputCurrentLowCurrent
+ Integer32,
+ pdnOutputCurrentVLowCurrent
+ Integer32,
+ pdnOutputFuseInEventState
+ DisplayString,
+ pdnOutputFuseValueStr
+ DisplayString,
+ pdnMainCombinedStatus
+ DisplayString,
+ pdnOutputCombinedStatusBlock1
+ DisplayString,
+ pdnOutputCombinedStatusBlock2
+ DisplayString,
+ pdnDeviceCurrentValue
+ Integer32,
+ pdnDeviceCurrentValueStr
+ DisplayString
+}
+
+CPEConfig ::=
+ SEQUENCE {
+ cpeIndex
+ Integer32,
+ cpeHost
+ DisplayString,
+ cpeName
+ DisplayString,
+ cpeDescription
+ DisplayString,
+ cpeKeepalive
+ Integer32,
+ cpeThreshold
+ Integer32,
+ cpeEventReminderInterval
+ Integer32,
+ cpeKeepaliveTicks
+ Integer32,
+ cpePingSize
+ Integer32,
+ cpeInfoReset
+ Integer32,
+ cpeInfoNumReq
+ Integer32,
+ cpeInfoNumGoodResp
+ Integer32,
+ cpeInfoNumBadResp
+ Integer32,
+ cpeInfoNumLostResp
+ Integer32,
+ cpeInfoPercentLoss
+ DisplayString,
+ cpeInfoPercentBad
+ DisplayString
+}
+
+ScriptingConfig ::=
+ SEQUENCE {
+ scrIndex
+ Integer32,
+ scrEnable
+ DisplayString,
+ scrName
+ DisplayString,
+ scrFilename
+ DisplayString,
+ scrRunAlways
+ DisplayString,
+ scrRunAtStartup
+ DisplayString,
+ scrRunScheduled
+ DisplayString,
+ scrScheduleTime
+ DisplayString,
+ scrArguments
+ DisplayString,
+ scrRepeatInterval
+ Integer32
+}
+
+ScriptingDTRCtrlPortEnableConfig ::=
+ SEQUENCE {
+ scrDTRCtrlPortEnableIndex
+ Integer32,
+ scrDTRCtrlPortEnable
+ DisplayString
+
+}
+
+ScriptingVolatileString ::=
+ SEQUENCE {
+ scrVolatileStringIndex
+ Integer32,
+ scrVolatileString
+ DisplayString
+}
+
+ScriptingVolatileInt ::=
+ SEQUENCE {
+ scrVolatileIntIndex
+ Integer32,
+ scrVolatileInt
+ Integer32
+}
+
+ScriptingNonVolatileString ::=
+ SEQUENCE {
+ scrNonVolatileStringIndex
+ Integer32,
+ scrNonVolatileString
+ DisplayString
+}
+
+ScriptingNonVolatileInt ::=
+ SEQUENCE {
+ scrNonVolatileIntIndex
+ Integer32,
+ scrNonVolatileInt
+ Integer32
+}
+
+CRDBFileEnforceMinConfig ::=
+ SEQUENCE {
+ sysCRDBFileEnforceMinIndex
+ Integer32,
+ sysCRDBFileEnforceMin
+ DisplayString
+}
+
+CRDBFileIDConfig ::=
+ SEQUENCE {
+ sysCRDBFileIDIndex
+ Integer32,
+ sysCRDBFileID
+ DisplayString
+}
+
+NetworkTimeHostConfig ::=
+ SEQUENCE {
+ sysTimeNetHostIndex
+ Integer32,
+ sysTimeNetHost
+ DisplayString
+}
+
+ActionHostConfig ::=
+ SEQUENCE {
+ actionHostIndex
+ Integer32,
+ actionHost
+ DisplayString
+}
+
+ActionEmailConfig ::=
+ SEQUENCE {
+ actionEmailIndex
+ Integer32,
+ actionEmail
+ DisplayString
+}
+
+FileEnforceMinimumConfig ::=
+ SEQUENCE {
+ sysCRDBFileEnforceMinIndex
+ Integer32,
+ sysCRDBFileEnforceMin
+ DisplayString
+}
+
+SerialHandshakingLowEventConfig ::=
+ SEQUENCE {
+ evShskLowIndex
+ Integer32,
+ evShskLowEnable
+ DisplayString,
+ evShskLowActions
+ DisplayString,
+ evShskLowMessage
+ DisplayString,
+ evShskLowClass
+ DisplayString,
+ evShskLowTrapNum
+ Integer32
+}
+
+SerialHandshakingHighEventConfig ::=
+ SEQUENCE {
+ evShskHighIndex
+ Integer32,
+ evShskHighEnable
+ DisplayString,
+ evShskHighActions
+ DisplayString,
+ evShskHighMessage
+ DisplayString,
+ evShskHighClass
+ DisplayString,
+ evShskHighTrapNum
+ Integer32
+}
+
+NoDataEvent1PortEnableConfig ::=
+ SEQUENCE {
+ evNoData1PortEnableIndex
+ Integer32,
+ evNoData1PortEnable
+ DisplayString
+}
+
+NoDataEvent2PortEnableConfig ::=
+ SEQUENCE {
+ evNoData2PortEnableIndex
+ Integer32,
+ evNoData2PortEnable
+ DisplayString
+}
+
+DataEventMacroConfig ::=
+ SEQUENCE {
+ evdMacroIndex
+ Integer32,
+ evdMacroName
+ DisplayString,
+ evdMacroEquation
+ DisplayString
+}
+
+DataEventFieldConfig ::=
+ SEQUENCE {
+ evdFieldIndex
+ Integer32,
+ evdFieldStart
+ Integer32,
+ evdFieldLength
+ Integer32,
+ evdFieldName
+ DisplayString,
+ evdFieldLine
+ Integer32,
+ evdFieldType
+ DisplayString
+}
+
+DataEventConfig ::=
+ SEQUENCE {
+ evdIndex
+ Integer32,
+ evdEnable
+ DisplayString,
+ evdName
+ DisplayString,
+ evdEquation
+ DisplayString,
+ evdThreshold
+ Integer32,
+ evdAutoClear
+ DisplayString,
+ evdClearInterval
+ DisplayString,
+ evdClearTime
+ DisplayString,
+ evdActions
+ DisplayString,
+ evdClass
+ DisplayString,
+ evdTrapNum
+ Integer32,
+ evdMode
+ DisplayString
+}
+
+SecUserConfig ::=
+ SEQUENCE {
+ secUserIndex
+ Integer32,
+ secUserEnable
+ DisplayString,
+ secUserConnectVia
+ DisplayString,
+ secUserLoginTo
+ DisplayString,
+ secUserAccessFile
+ DisplayString,
+ secUserPTEscapeTo
+ DisplayString,
+ secUserPPPType
+ DisplayString,
+ secUserRights
+ DisplayString,
+ secUserEventsReadAccess
+ DisplayString,
+ secUserAuditReadAccess
+ DisplayString,
+ secUserEventsWriteAccess
+ DisplayString,
+ secUserAuditWriteAccess
+ DisplayString,
+ secUserExpiration
+ DisplayString,
+ secUserCallbackNumber1
+ DisplayString,
+ secUserCallbackNumber2
+ DisplayString,
+ secUserCallbackNumber3
+ DisplayString,
+ secUserChallengeTelnetMode
+ DisplayString,
+ secUserChallengeModemMode
+ DisplayString,
+ secUserChallengeConsoleMode
+ DisplayString,
+ secUserChallengeTelnetSendTo
+ DisplayString,
+ secUserChallengeModemSendTo
+ DisplayString,
+ secUserChallengeExpiration
+ Integer32
+}
+
+
+
+
+ModemCLIDNumberConfig ::=
+ SEQUENCE {
+ modemCLIDNumberIndex
+ Integer32,
+ modemCLIDNumber
+ DisplayString
+}
+
+
+RouteTestConfig ::=
+ SEQUENCE {
+ routeTestAddressIndex
+ Integer32,
+ routeTestAddress
+ DisplayString
+}
+
+IPRestrictionConfig ::=
+ SEQUENCE {
+ ipRestrictionIndex
+ Integer32,
+ ipRestrictionEnable
+ DisplayString,
+ ipRestrictionMask
+ DisplayString
+}
+
+DNSConfig ::=
+ SEQUENCE {
+ dnsIndex
+ Integer32,
+ dnsAddress
+ IpAddress
+}
+
+HostConfig ::=
+ SEQUENCE {
+ hostIndex
+ Integer32,
+ hostDeclaration
+ DisplayString
+}
+
+SNMPPollRequestConfig ::=
+ SEQUENCE {
+ snmpPRequestIndex
+ Integer32,
+ snmpPRequestDescription
+ DisplayString,
+ snmpPRequestAgent
+ DisplayString,
+ snmpPRequestReadcom
+ DisplayString,
+ snmpPRequestOID
+ DisplayString,
+ snmpPRequestPeriod
+ Integer32,
+ snmpPRequestID
+ DisplayString,
+ snmpPRequestThreshold
+ DisplayString,
+ snmpPRequestResultStatus
+ DisplayString,
+ snmpPRequestResultValue
+ DisplayString,
+ snmpPRequestResultTime
+ DisplayString,
+ snmpPRequestResultType
+ DisplayString
+}
+
+FTPPushPushFileConfig ::=
+ SEQUENCE {
+ ftpPushPushFileIndex
+ Integer32,
+ ftpPushPushFile
+ DisplayString
+}
+
+FTPPushRemoteFileConfig ::=
+ SEQUENCE {
+ ftpPushRemoteFileIndex
+ Integer32,
+ ftpPushRemoteFileName
+ DisplayString
+}
+
+PortConfig ::=
+ SEQUENCE {
+ portConfigIndex
+ Integer32,
+ portConfigBaud
+ Integer32,
+ portConfigDataFormat
+ Integer32,
+ portConfigStripPtOutputLfs
+ Integer32,
+ portConfigStripPtInputLfs
+ Integer32,
+ portConfigMaskEnable
+ Integer32,
+ portConfigDAEnable
+ Integer32,
+ portConfigStoreAlarmsDPT
+ DisplayString,
+ portConfigRecordTimeout
+ Integer32,
+ portConfigDataType
+ DisplayString,
+ portConfigEtxToCRLF
+ DisplayString,
+ portConfigMLREnable
+ DisplayString,
+ portConfigMLRStartField1Pos
+ Integer32,
+ portConfigMLRStartField1Text
+ DisplayString,
+ portConfigMLRStartField2Pos
+ Integer32,
+ portConfigMLRStartField2Text
+ DisplayString,
+ portConfigMLRNumLinesBefore
+ Integer32,
+ portConfigMLREndDetection
+ DisplayString,
+ portConfigMLRLineCount
+ Integer32,
+ portConfigMLREndField1Pos
+ Integer32,
+ portConfigMLREndField1Text
+ DisplayString,
+ portConfigMLREndField2Pos
+ Integer32,
+ portConfigMLREndField2Text
+ DisplayString,
+ portConfigMLRUseComplexRules
+ DisplayString,
+ portConfigBufferPT
+ DisplayString,
+ portConfigId
+ DisplayString,
+ portConfigMode
+ DisplayString,
+ portConfigHsk
+ DisplayString
+
+}
+
+ESPoint ::=
+ SEQUENCE {
+ esIndexES
+ Integer32,
+ esIndexPC
+ Integer32,
+ esIndexPoint
+ Integer32,
+ esPointName
+ DisplayString,
+ esPointInEventState
+ Integer32,
+ esPointValueInt
+ Integer32,
+ esPointValueStr
+ DisplayString,
+ esPointTimeLastChange
+ DisplayString,
+ esPointTimetickLastChange
+ TimeTicks
+}
+
+ESExist ::=
+ SEQUENCE {
+ esIndex
+ Integer32,
+ esName
+ DisplayString,
+ esID
+ DisplayString,
+ esNumberTempSensors
+ Integer32,
+ esTempReportingMode
+ DisplayString,
+ esNumberCCs
+ Integer32,
+ esCCReportingMode
+ DisplayString,
+ esNumberHumidSensors
+ Integer32,
+ esHumidReportingMode
+ DisplayString,
+ esNumberNoiseSensors
+ Integer32,
+ esNoiseReportingMode
+ DisplayString,
+ esNumberAirflowSensors
+ Integer32,
+ esAirflowReportingMode
+ DisplayString,
+ esNumberAnalog
+ Integer32,
+ esAnalogReportingMode
+ DisplayString,
+ esNumberOutputs
+ Integer32,
+ esOutputReportingMode
+ DisplayString,
+ esTempCombinedStatus
+ DisplayString,
+ esCCCombinedStatusBlock1
+ DisplayString,
+ esCCCombinedStatusBlock2
+ DisplayString,
+ esCCCombinedStatusBlock3
+ DisplayString,
+ esCCCombinedStatusBlock4
+ DisplayString,
+ esCCCombinedStatusBlock5
+ DisplayString,
+ esCCCombinedStatusBlock6
+ DisplayString,
+ esCCCombinedStatusBlock7
+ DisplayString,
+ esCCCombinedStatusBlock8
+ DisplayString,
+ esHumidCombinedStatus
+ DisplayString,
+ esAnalogCombinedStatusBlock1
+ DisplayString,
+ esAnalogCombinedStatusBlock2
+ DisplayString,
+ esAnalogCombinedStatusBlock3
+ DisplayString,
+ esAnalogCombinedStatusBlock4
+ DisplayString,
+ esAnalogCombinedStatusBlock5
+ DisplayString,
+ esAnalogCombinedStatusBlock6
+ DisplayString,
+ esOutputCombinedStatusBlock1
+ DisplayString,
+ esOutputCombinedStatusBlock2
+ DisplayString
+}
+
+DEStatus ::=
+ SEQUENCE {
+ deStatusIndex
+ Integer32,
+ deStatusName
+ DisplayString,
+ deStatusCounter
+ Integer32,
+ deStatusThreshold
+ Integer32
+}
+
+AISGALD ::=
+ SEQUENCE {
+ aisgsALDIndex
+ Integer32,
+ aisgsALDSectorID
+ DisplayString,
+ aisgsALDType
+ DisplayString,
+ aisgsALDDescription
+ DisplayString,
+ aisgsALDStatus
+ DisplayString,
+ aisgsALDID
+ DisplayString,
+ aisgsALDTilt
+ DisplayString,
+ aisgsALDHwVersion
+ DisplayString,
+ aisgsALDSwVersion
+ DisplayString,
+ aisgsALDModel
+ DisplayString,
+ aisgsALDAntennaModel
+ DisplayString,
+ aisgsALDMinTilt
+ DisplayString,
+ aisgsALDMaxTilt
+ DisplayString,
+ aisgsALDAISGVersion
+ DisplayString
+}
+
+AISGFile ::=
+ SEQUENCE {
+ aisgsFileIndex
+ Integer32,
+ aisgsFileName
+ DisplayString,
+ aisgsFileType
+ DisplayString,
+ aisgsFileVersion
+ DisplayString
+}
+
+AISGAuto ::=
+ SEQUENCE {
+ aisgsAutoIndex
+ Integer32,
+ aisgsAutoVendor
+ DisplayString,
+ aisgsAutoALDModel
+ DisplayString,
+ aisgsAutoSoftware
+ DisplayString,
+ aisgsAutoConfig
+ DisplayString,
+ aisgsAutoTilt
+ DisplayString
+}
+
+AISGAAA ::=
+ SEQUENCE {
+ aisgsAAAIndex
+ Integer32,
+ aisgsAAAALDID
+ DisplayString,
+ aisgsAAAAntennaSN
+ DisplayString,
+ aisgsAAASectorID
+ DisplayString
+}
+
+FSStatus ::=
+ SEQUENCE {
+ fsStatusIndex
+ Integer32,
+ fsStatusName
+ DisplayString,
+ fsStatusDeviceState
+ DisplayString,
+ fsStatusVolumeValueString
+ DisplayString,
+ fsStatusVolumePercentLevel
+ DisplayString,
+ fsStatusVolumeInEventState
+ DisplayString,
+ fsStatusCombined
+ DisplayString
+}
+
+ACPMStatus ::=
+ SEQUENCE {
+ acpmsIndex
+ Integer32,
+ acpmsName
+ DisplayString,
+ acpmsAvgVoltageValueStr
+ DisplayString,
+ acpmsAvgVoltageMinStr
+ DisplayString,
+ acpmsAvgVoltageMaxStr
+ DisplayString,
+ acpmsAvgVoltageAvgStr
+ DisplayString,
+ acpmsAvgVoltageInEventState
+ DisplayString,
+ acpmsVoltagePhaseAValueStr
+ DisplayString,
+ acpmsVoltagePhaseBValueStr
+ DisplayString,
+ acpmsVoltagePhaseCValueStr
+ DisplayString,
+ acpmsAvgCurrentValueStr
+ DisplayString,
+ acpmsAvgCurrentMinStr
+ DisplayString,
+ acpmsAvgCurrentMaxStr
+ DisplayString,
+ acpmsAvgCurrentAvgStr
+ DisplayString,
+ acpmsAvgCurrentInEventState
+ DisplayString,
+ acpmsCurrentPhaseAValueStr
+ DisplayString,
+ acpmsCurrentPhaseBValueStr
+ DisplayString,
+ acpmsCurrentPhaseCValueStr
+ DisplayString,
+ acpmsAvgFreqValueStr
+ DisplayString,
+ acpmsAvgFreqMinStr
+ DisplayString,
+ acpmsAvgFreqMaxStr
+ DisplayString,
+ acpmsAvgFreqAvgStr
+ DisplayString,
+ acpmsAvgFreqInEventState
+ DisplayString,
+ acpmsTRPValueStr
+ DisplayString,
+ acpmsTRPMinStr
+ DisplayString,
+ acpmsTRPMaxStr
+ DisplayString,
+ acpmsTRPAvgStr
+ DisplayString,
+ acpmsTRPInEventState
+ DisplayString,
+ acpmsRPPhaseAValueStr
+ DisplayString,
+ acpmsRPPhaseBValueStr
+ DisplayString,
+ acpmsRPPhaseCValueStr
+ DisplayString,
+ acpmsCombined
+ DisplayString,
+ acpmsTPFValueStr
+ DisplayString,
+ acpmsTPFMinStr
+ DisplayString,
+ acpmsTPFMaxStr
+ DisplayString,
+ acpmsTPFAvgStr
+ DisplayString,
+ acpmsTPFInEventState
+ DisplayString,
+ acpmsPFPhaseAValueStr
+ DisplayString,
+ acpmsPFPhaseBValueStr
+ DisplayString,
+ acpmsPFPhaseCValueStr
+ DisplayString,
+ acpmsTRcPValueStr
+ DisplayString,
+ acpmsTRcPMinStr
+ DisplayString,
+ acpmsTRcPMaxStr
+ DisplayString,
+ acpmsTRcPAvgStr
+ DisplayString,
+ acpmsRcPPhaseAValueStr
+ DisplayString,
+ acpmsRcPPhaseBValueStr
+ DisplayString,
+ acpmsRcPPhaseCValueStr
+ DisplayString,
+ acpmsTAPValueStr
+ DisplayString,
+ acpmsTAPMinStr
+ DisplayString,
+ acpmsTAPMaxStr
+ DisplayString,
+ acpmsTAPAvgStr
+ DisplayString,
+ acpmsAPPhaseAValueStr
+ DisplayString,
+ acpmsAPPhaseBValueStr
+ DisplayString,
+ acpmsAPPhaseCValueStr
+ DisplayString,
+ acpmsTotalEnergyWh
+ Integer32,
+ acpmsTotalEnergyVAR
+ Integer32,
+ acpmsTotalEnergyVA
+ Integer32
+}
+
+FuelSensorConfigGeneral ::=
+ SEQUENCE {
+ fsGenIndex
+ Integer32,
+ fsGenName
+ DisplayString,
+ fsGenSensorType
+ DisplayString,
+ fsGenDistanceUnit
+ DisplayString,
+ fsGenRawValueTop
+ DisplayString,
+ fsGenTopOffset
+ DisplayString,
+ fsGenRawValueBottom
+ DisplayString,
+ fsGenBottomOffset
+ DisplayString,
+ fsGenInputES
+ Integer32,
+ fsGenInputPoint
+ Integer32,
+ fsGenFilterAveraging
+ Integer32,
+ fsGenSysrepEnable
+ DisplayString,
+ fsGenSysrepThreshold
+ DisplayString,
+ fsGenSysrepLimit
+ Integer32,
+ fsGenSysrepPackage
+ Integer32,
+ fsGenSysrepType
+ DisplayString,
+ fsGenEnable
+ DisplayString
+}
+
+FuelSensorConfigTank ::=
+ SEQUENCE {
+ fsTankIndex
+ Integer32,
+ fsTankHeight
+ DisplayString,
+ fsTankDimA
+ DisplayString,
+ fsTankDimB
+ DisplayString,
+ fsTankVolume
+ DisplayString,
+ fsTankVolumeUnit
+ DisplayString,
+ fsTankShape
+ DisplayString
+}
+
+FuelSensorConfigCustomTankStrapping ::=
+ SEQUENCE {
+ fsCustomTankIndexFS
+ Integer32,
+ fsCustomTankIndexDatum
+ Integer32,
+ fsCustomTankHeight
+ DisplayString,
+ fsCustomTankVolume
+ DisplayString
+}
+
+FuelSensorConfigVolume ::=
+ SEQUENCE {
+ fsVolumeIndex
+ Integer32,
+ fsVolumeEnable
+ DisplayString,
+ fsVolumeDeadband
+ DisplayString,
+ fsVolumeVHighValue
+ DisplayString,
+ fsVolumeVHighActions
+ DisplayString,
+ fsVolumeVHighTrapNum
+ Integer32,
+ fsVolumeVHighClass
+ DisplayString,
+ fsVolumeHighValue
+ DisplayString,
+ fsVolumeHighActions
+ DisplayString,
+ fsVolumeHighTrapNum
+ Integer32,
+ fsVolumeHighClass
+ DisplayString,
+ fsVolumeNormalActions
+ DisplayString,
+ fsVolumeNormalTrapNum
+ Integer32,
+ fsVolumeNormalClass
+ DisplayString,
+ fsVolumeLowValue
+ DisplayString,
+ fsVolumeLowActions
+ DisplayString,
+ fsVolumeLowTrapNum
+ Integer32,
+ fsVolumeLowClass
+ DisplayString,
+ fsVolumeVLowValue
+ DisplayString,
+ fsVolumeVLowActions
+ DisplayString,
+ fsVolumeVLowTrapNum
+ Integer32,
+ fsVolumeVLowClass
+ DisplayString
+}
+
+FuelSensorConfigDisconnect ::=
+ SEQUENCE {
+ fsDiscIndex
+ Integer32,
+ fsDiscEnable
+ DisplayString,
+ fsDiscHighValue
+ DisplayString,
+ fsDiscLowValue
+ DisplayString,
+ fsDiscActions
+ DisplayString,
+ fsDiscTrapNum
+ Integer32,
+ fsDiscClass
+ DisplayString,
+ fsDiscNormalActions
+ DisplayString,
+ fsDiscNormalTrapNum
+ Integer32,
+ fsDiscNormalClass
+ DisplayString
+}
+
+ACPMConfigGeneral ::=
+ SEQUENCE {
+ acpmGenIndex
+ Integer32,
+ acpmGenDevice
+ DisplayString,
+ acpmGenName
+ DisplayString,
+ acpmGenAddress
+ Integer32,
+ acpmGenPtRatio
+ Integer32,
+ acpmGenCtRatio
+ Integer32,
+ acpmGenPowerType
+ DisplayString,
+ acpmGenSysrepPackage
+ Integer32,
+ acpmGenSysrepType
+ DisplayString,
+ acpmGenEnable
+ DisplayString
+}
+
+ACPMConfigAvgVoltage ::=
+ SEQUENCE {
+ acpmAvgVoltageIndex
+ Integer32,
+ acpmAvgVoltageEnable
+ DisplayString,
+ acpmAvgVoltageDeadband
+ DisplayString,
+ acpmAvgVoltageVHighValue
+ DisplayString,
+ acpmAvgVoltageVHighActions
+ DisplayString,
+ acpmAvgVoltageVHighTrapNum
+ Integer32,
+ acpmAvgVoltageVHighClass
+ DisplayString,
+ acpmAvgVoltageHighValue
+ DisplayString,
+ acpmAvgVoltageHighActions
+ DisplayString,
+ acpmAvgVoltageHighTrapNum
+ Integer32,
+ acpmAvgVoltageHighClass
+ DisplayString,
+ acpmAvgVoltageNormalActions
+ DisplayString,
+ acpmAvgVoltageNormalTrapNum
+ Integer32,
+ acpmAvgVoltageNormalClass
+ DisplayString,
+ acpmAvgVoltageLowValue
+ DisplayString,
+ acpmAvgVoltageLowActions
+ DisplayString,
+ acpmAvgVoltageLowTrapNum
+ Integer32,
+ acpmAvgVoltageLowClass
+ DisplayString,
+ acpmAvgVoltageVLowValue
+ DisplayString,
+ acpmAvgVoltageVLowActions
+ DisplayString,
+ acpmAvgVoltageVLowTrapNum
+ Integer32,
+ acpmAvgVoltageVLowClass
+ DisplayString,
+ acpmAvgVoltageSysrepEnable
+ DisplayString,
+ acpmAvgVoltageSysrepThreshold
+ DisplayString,
+ acpmAvgVoltageSysrepLimit
+ Integer32
+}
+
+ACPMConfigAvgCurrent ::=
+ SEQUENCE {
+ acpmAvgCurrentIndex
+ Integer32,
+ acpmAvgCurrentEnable
+ DisplayString,
+ acpmAvgCurrentDeadband
+ DisplayString,
+ acpmAvgCurrentVHighValue
+ DisplayString,
+ acpmAvgCurrentVHighActions
+ DisplayString,
+ acpmAvgCurrentVHighTrapNum
+ Integer32,
+ acpmAvgCurrentVHighClass
+ DisplayString,
+ acpmAvgCurrentHighValue
+ DisplayString,
+ acpmAvgCurrentHighActions
+ DisplayString,
+ acpmAvgCurrentHighTrapNum
+ Integer32,
+ acpmAvgCurrentHighClass
+ DisplayString,
+ acpmAvgCurrentNormalActions
+ DisplayString,
+ acpmAvgCurrentNormalTrapNum
+ Integer32,
+ acpmAvgCurrentNormalClass
+ DisplayString,
+ acpmAvgCurrentLowValue
+ DisplayString,
+ acpmAvgCurrentLowActions
+ DisplayString,
+ acpmAvgCurrentLowTrapNum
+ Integer32,
+ acpmAvgCurrentLowClass
+ DisplayString,
+ acpmAvgCurrentVLowValue
+ DisplayString,
+ acpmAvgCurrentVLowActions
+ DisplayString,
+ acpmAvgCurrentVLowTrapNum
+ Integer32,
+ acpmAvgCurrentVLowClass
+ DisplayString,
+ acpmAvgCurrentSysrepEnable
+ DisplayString,
+ acpmAvgCurrentSysrepThreshold
+ DisplayString,
+ acpmAvgCurrentSysrepLimit
+ Integer32
+}
+
+ACPMConfigFreq ::=
+ SEQUENCE {
+ acpmFreqIndex
+ Integer32,
+ acpmFreqEnable
+ DisplayString,
+ acpmFreqDeadband
+ DisplayString,
+ acpmFreqVHighValue
+ DisplayString,
+ acpmFreqVHighActions
+ DisplayString,
+ acpmFreqVHighTrapNum
+ Integer32,
+ acpmFreqVHighClass
+ DisplayString,
+ acpmFreqHighValue
+ DisplayString,
+ acpmFreqHighActions
+ DisplayString,
+ acpmFreqHighTrapNum
+ Integer32,
+ acpmFreqHighClass
+ DisplayString,
+ acpmFreqNormalActions
+ DisplayString,
+ acpmFreqNormalTrapNum
+ Integer32,
+ acpmFreqNormalClass
+ DisplayString,
+ acpmFreqLowValue
+ DisplayString,
+ acpmFreqLowActions
+ DisplayString,
+ acpmFreqLowTrapNum
+ Integer32,
+ acpmFreqLowClass
+ DisplayString,
+ acpmFreqVLowValue
+ DisplayString,
+ acpmFreqVLowActions
+ DisplayString,
+ acpmFreqVLowTrapNum
+ Integer32,
+ acpmFreqVLowClass
+ DisplayString,
+ acpmFreqSysrepEnable
+ DisplayString,
+ acpmFreqSysrepThreshold
+ DisplayString,
+ acpmFreqSysrepLimit
+ Integer32
+}
+
+ACPMConfigTRP ::=
+ SEQUENCE {
+ acpmTRPIndex
+ Integer32,
+ acpmTRPEnable
+ DisplayString,
+ acpmTRPDeadband
+ DisplayString,
+ acpmTRPVHighValue
+ DisplayString,
+ acpmTRPVHighActions
+ DisplayString,
+ acpmTRPVHighTrapNum
+ Integer32,
+ acpmTRPVHighClass
+ DisplayString,
+ acpmTRPHighValue
+ DisplayString,
+ acpmTRPHighActions
+ DisplayString,
+ acpmTRPHighTrapNum
+ Integer32,
+ acpmTRPHighClass
+ DisplayString,
+ acpmTRPNormalActions
+ DisplayString,
+ acpmTRPNormalTrapNum
+ Integer32,
+ acpmTRPNormalClass
+ DisplayString,
+ acpmTRPLowValue
+ DisplayString,
+ acpmTRPLowActions
+ DisplayString,
+ acpmTRPLowTrapNum
+ Integer32,
+ acpmTRPLowClass
+ DisplayString,
+ acpmTRPVLowValue
+ DisplayString,
+ acpmTRPVLowActions
+ DisplayString,
+ acpmTRPVLowTrapNum
+ Integer32,
+ acpmTRPVLowClass
+ DisplayString,
+ acpmTRPSysrepEnable
+ DisplayString,
+ acpmTRPSysrepThreshold
+ DisplayString,
+ acpmTRPSysrepLimit
+ Integer32
+}
+
+ACPMConfigDisconnect ::=
+ SEQUENCE {
+ acpmDisconnectIndex
+ Integer32,
+ acpmDisconnectEnable
+ DisplayString,
+ acpmDisconnectActions
+ DisplayString,
+ acpmDisconnectTrapNum
+ Integer32,
+ acpmDisconnectClass
+ DisplayString,
+ acpmDisconnectNormalActions
+ DisplayString,
+ acpmDisconnectNormalTrapNum
+ Integer32,
+ acpmDisconnectNormalClass
+ DisplayString
+}
+
+ACPMConfigTotalPowerFactor ::=
+ SEQUENCE {
+ acpmTPFIndex
+ Integer32,
+ acpmTPFEnable
+ DisplayString,
+ acpmTPFDeadband
+ DisplayString,
+ acpmTPFNormalActions
+ DisplayString,
+ acpmTPFNormalTrapNum
+ Integer32,
+ acpmTPFNormalClass
+ DisplayString,
+ acpmTPFLowValue
+ DisplayString,
+ acpmTPFLowActions
+ DisplayString,
+ acpmTPFLowTrapNum
+ Integer32,
+ acpmTPFLowClass
+ DisplayString,
+ acpmTPFVLowValue
+ DisplayString,
+ acpmTPFVLowActions
+ DisplayString,
+ acpmTPFVLowTrapNum
+ Integer32,
+ acpmTPFVLowClass
+ DisplayString,
+ acpmTPFSysrepEnable
+ DisplayString,
+ acpmTPFSysrepThreshold
+ DisplayString,
+ acpmTPFSysrepLimit
+ Integer32
+}
+
+
+--***************************************************************************************
+--TRAP DEFINITIONS
+--***************************************************************************************
+
+s571StockContactClosureTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock contact closure trap is issued when a contact closure
+ event happens."
+ ::= { s571 110 }
+
+s571StockTempTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock temperature trap is issued when a temperature event
+ happens."
+ ::= { s571 120 }
+
+s571StockHumidityTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock humidity trap is issued when a humidity event
+ happens."
+ ::= { s571 130 }
+
+s571StockAnalogTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock analog trap is issued when an analog sensor event
+ happens."
+ ::= { s571 140 }
+
+s571StockOutputTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock output trap is issued when an output event
+ happens. That is, depending on the configuration,
+ when an output changes state for any reason, this
+ trap will be sent."
+ ::= { s571 150 }
+
+s571StockPDCurrentTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock analog trap is issued when a power distribution
+ current event happens."
+ ::= { s571 180 }
+
+s571StockPDVoltageTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock analog trap is issued when a power distribution
+ voltage event happens."
+ ::= { s571 190 }
+
+s571StockPDFuseTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock analog trap is issued when a power distribution
+ fuse event happens."
+ ::= { s571 210 }
+
+s571StockDataAlarmTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "The stock data alarm trap is issued when a
+ data alarm happens."
+ ::= { s571 503 }
+
+s571StockNoDataAlarmTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "The stock no-data alarm trap is issued when
+ the unit has received no data for a configured
+ interval within a configured schedule."
+ ::= { s571 505 }
+
+s571StockSchedTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "The stock scheduled alarm trap is issued
+ when the current time reaches the scheduled
+ alarm time."
+ ::= { s571 506 }
+
+s571StockImmediateTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "The stock immediate alarm trap is issued
+ when the user enters the DOTRAP command."
+ ::= { s571 507 }
+
+s571StockCTSTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock CTS trap is issued when an RS-232 CTS event
+ happens."
+ ::= { s571 510 }
+
+s571CPEDownTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock CPE Down trap is issued when a CPE Down event
+ happens."
+ ::= { s571 511 }
+
+s571FuelSensorDisconnectTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock Fuel Sensor Disconnect trap is issued when a Fuel
+ Sensor Disconnect or Connect (Return to Normal) event happens."
+ ::= { s571 515 }
+
+s571FuelSensorVolumeTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock Fuel Sensor Volume trap is issued when a Fuel
+ Sensor Volume event happens"
+ ::= { s571 519 }
+
+s571ACPowerMonitorAvgVoltageTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock AC power monitor average voltage trap is issued when an
+ AC power monitor average voltage event happens."
+ ::= { s571 520 }
+
+s571ACPowerMonitorAvgCurrentTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock AC power monitor average current trap is issued when an
+ AC power monitor average current event happens."
+ ::= { s571 521 }
+
+s571ACPowerMonitorFrequencyTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock AC power monitor frequency trap is issued when an
+ AC power monitor frequency event happens."
+ ::= { s571 522 }
+
+s571ACPowerMonitorTRPTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock AC power monitor TRP (total real power) trap is issued
+ when an AC power monitor TRP event happens."
+ ::= { s571 523 }
+
+s571ACPowerMonitorDisconnectTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock AC power monitor disconnect trap is issued
+ when an AC power monitor disconnect event happens."
+ ::= { s571 524 }
+
+s571StockLoadSheddingTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock Load Shedding trap is issued when a Load Shedding event
+ happens."
+ ::= { s571 525 }
+
+s571StockScriptTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock script trap is issued when a script triggers
+ an event via a_lib.PostEvent() called with no trap
+ number (or this trap number) specified."
+ ::= { s571 526 }
+
+s571FuelSensorVolumeSuddenChangeTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock Fuel Sensor Volume Sudden Change trap is issued
+ when a Fuel Sensor Volume Sudden Change event happens"
+ ::= { s571 527 }
+
+s571FuelSensorVolumeSlowChangeTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock Fuel Sensor Volume Slow Change trap is issued
+ when a Fuel Sensor Volume Slow Change event happens"
+ ::= { s571 528 }
+
+s571ACTotalPowerFactorTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock AC power monitor total power factor trap is issued
+ when an AC power monitor total power factor event happens."
+ ::= { s571 540 }
+
+s571ResetTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock reset trap is issued when a reset event happens."
+ ::= { s571 543 }
+
+s571UserTrap1000 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1000."
+ ::= { s571 1000 }
+
+s571UserTrap1001 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1001."
+ ::= { s571 1001 }
+
+s571UserTrap1002 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1002."
+ ::= { s571 1002 }
+
+s571UserTrap1003 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1003."
+ ::= { s571 1003 }
+
+s571UserTrap1004 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1004."
+ ::= { s571 1004 }
+
+s571UserTrap1005 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1005."
+ ::= { s571 1005 }
+
+s571UserTrap1006 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1006."
+ ::= { s571 1006 }
+
+s571UserTrap1007 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1007."
+ ::= { s571 1007 }
+
+s571UserTrap1008 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1008."
+ ::= { s571 1008 }
+
+s571UserTrap1009 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1009."
+ ::= { s571 1009 }
+
+s571UserTrap1010 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1010."
+ ::= { s571 1010 }
+
+s571UserTrap1011 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1011."
+ ::= { s571 1011 }
+
+s571UserTrap1012 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1012."
+ ::= { s571 1012 }
+
+s571UserTrap1013 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1013."
+ ::= { s571 1013 }
+
+s571UserTrap1014 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1014."
+ ::= { s571 1014 }
+
+s571UserTrap1015 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1015."
+ ::= { s571 1015 }
+
+s571UserTrap1016 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1016."
+ ::= { s571 1016 }
+
+s571UserTrap1017 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1017."
+ ::= { s571 1017 }
+
+s571UserTrap1018 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1018."
+ ::= { s571 1018 }
+
+s571UserTrap1019 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1019."
+ ::= { s571 1019 }
+
+s571UserTrap1020 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1020."
+ ::= { s571 1020 }
+
+s571UserTrap1021 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1021."
+ ::= { s571 1021 }
+
+s571UserTrap1022 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1022."
+ ::= { s571 1022 }
+
+s571UserTrap1023 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1023."
+ ::= { s571 1023 }
+
+s571UserTrap1024 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1024."
+ ::= { s571 1024 }
+
+s571UserTrap1025 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1025."
+ ::= { s571 1025 }
+
+s571UserTrap1026 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1026."
+ ::= { s571 1026 }
+
+s571UserTrap1027 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1027."
+ ::= { s571 1027 }
+
+s571UserTrap1028 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1028."
+ ::= { s571 1028 }
+
+s571UserTrap1029 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1029."
+ ::= { s571 1029 }
+
+s571UserTrap1030 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1030."
+ ::= { s571 1030 }
+
+s571UserTrap1031 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1031."
+ ::= { s571 1031 }
+
+s571UserTrap1032 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1032."
+ ::= { s571 1032 }
+
+s571UserTrap1033 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1033."
+ ::= { s571 1033 }
+
+s571UserTrap1034 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1034."
+ ::= { s571 1034 }
+
+s571UserTrap1035 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1035."
+ ::= { s571 1035 }
+
+s571UserTrap1036 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1036."
+ ::= { s571 1036 }
+
+s571UserTrap1037 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1037."
+ ::= { s571 1037 }
+
+s571UserTrap1038 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1038."
+ ::= { s571 1038 }
+
+s571UserTrap1039 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1039."
+ ::= { s571 1039 }
+
+s571UserTrap1040 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1040."
+ ::= { s571 1040 }
+
+s571UserTrap1041 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1041."
+ ::= { s571 1041 }
+
+s571UserTrap1042 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1042."
+ ::= { s571 1042 }
+
+s571UserTrap1043 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1043."
+ ::= { s571 1043 }
+
+s571UserTrap1044 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1044."
+ ::= { s571 1044 }
+
+s571UserTrap1045 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1045."
+ ::= { s571 1045 }
+
+s571UserTrap1046 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1046."
+ ::= { s571 1046 }
+
+s571UserTrap1047 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1047."
+ ::= { s571 1047 }
+
+s571UserTrap1048 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1048."
+ ::= { s571 1048 }
+
+s571UserTrap1049 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1049."
+ ::= { s571 1049 }
+
+s571UserTrap1050 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1050."
+ ::= { s571 1050 }
+
+s571UserTrap1051 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1051."
+ ::= { s571 1051 }
+
+s571UserTrap1052 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1052."
+ ::= { s571 1052 }
+
+s571UserTrap1053 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1053."
+ ::= { s571 1053 }
+
+s571UserTrap1054 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1054."
+ ::= { s571 1054 }
+
+s571UserTrap1055 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1055."
+ ::= { s571 1055 }
+
+s571UserTrap1056 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1056."
+ ::= { s571 1056 }
+
+s571UserTrap1057 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1057."
+ ::= { s571 1057 }
+
+s571UserTrap1058 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1058."
+ ::= { s571 1058 }
+
+s571UserTrap1059 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1059."
+ ::= { s571 1059 }
+
+s571UserTrap1060 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1060."
+ ::= { s571 1060 }
+
+s571UserTrap1061 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1061."
+ ::= { s571 1061 }
+
+s571UserTrap1062 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1062."
+ ::= { s571 1062 }
+
+s571UserTrap1063 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1063."
+ ::= { s571 1063 }
+
+s571UserTrap1064 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1064."
+ ::= { s571 1064 }
+
+s571UserTrap1065 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1065."
+ ::= { s571 1065 }
+
+s571UserTrap1066 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1066."
+ ::= { s571 1066 }
+
+s571UserTrap1067 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1067."
+ ::= { s571 1067 }
+
+s571UserTrap1068 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1068."
+ ::= { s571 1068 }
+
+s571UserTrap1069 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1069."
+ ::= { s571 1069 }
+
+s571UserTrap1070 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1070."
+ ::= { s571 1070 }
+
+s571UserTrap1071 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1071."
+ ::= { s571 1071 }
+
+s571UserTrap1072 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1072."
+ ::= { s571 1072 }
+
+s571UserTrap1073 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1073."
+ ::= { s571 1073 }
+
+s571UserTrap1074 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1074."
+ ::= { s571 1074 }
+
+s571UserTrap1075 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1075."
+ ::= { s571 1075 }
+
+s571UserTrap1076 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1076."
+ ::= { s571 1076 }
+
+s571UserTrap1077 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1077."
+ ::= { s571 1077 }
+
+s571UserTrap1078 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1078."
+ ::= { s571 1078 }
+
+s571UserTrap1079 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1079."
+ ::= { s571 1079 }
+
+s571UserTrap1080 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1080."
+ ::= { s571 1080 }
+
+s571UserTrap1081 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1081."
+ ::= { s571 1081 }
+
+s571UserTrap1082 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1082."
+ ::= { s571 1082 }
+
+s571UserTrap1083 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1083."
+ ::= { s571 1083 }
+
+s571UserTrap1084 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1084."
+ ::= { s571 1084 }
+
+s571UserTrap1085 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1085."
+ ::= { s571 1085 }
+
+s571UserTrap1086 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1086."
+ ::= { s571 1086 }
+
+s571UserTrap1087 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1087."
+ ::= { s571 1087 }
+
+s571UserTrap1088 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1088."
+ ::= { s571 1088 }
+
+s571UserTrap1089 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1089."
+ ::= { s571 1089 }
+
+s571UserTrap1090 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1090."
+ ::= { s571 1090 }
+
+s571UserTrap1091 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1091."
+ ::= { s571 1091 }
+
+s571UserTrap1092 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1092."
+ ::= { s571 1092 }
+
+s571UserTrap1093 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1093."
+ ::= { s571 1093 }
+
+s571UserTrap1094 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1094."
+ ::= { s571 1094 }
+
+s571UserTrap1095 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1095."
+ ::= { s571 1095 }
+
+s571UserTrap1096 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1096."
+ ::= { s571 1096 }
+
+s571UserTrap1097 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1097."
+ ::= { s571 1097 }
+
+s571UserTrap1098 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1098."
+ ::= { s571 1098 }
+
+s571UserTrap1099 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1099."
+ ::= { s571 1099 }
+
+s571UserTrap1100 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1100."
+ ::= { s571 1100 }
+
+s571UserTrap1101 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1101."
+ ::= { s571 1101 }
+
+s571UserTrap1102 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1102."
+ ::= { s571 1102 }
+
+s571UserTrap1103 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1103."
+ ::= { s571 1103 }
+
+s571UserTrap1104 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1104."
+ ::= { s571 1104 }
+
+s571UserTrap1105 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1105."
+ ::= { s571 1105 }
+
+s571UserTrap1106 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1106."
+ ::= { s571 1106 }
+
+s571UserTrap1107 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1107."
+ ::= { s571 1107 }
+
+s571UserTrap1108 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1108."
+ ::= { s571 1108 }
+
+s571UserTrap1109 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1109."
+ ::= { s571 1109 }
+
+s571UserTrap1110 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1110."
+ ::= { s571 1110 }
+
+s571UserTrap1111 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1111."
+ ::= { s571 1111 }
+
+s571UserTrap1112 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1112."
+ ::= { s571 1112 }
+
+s571UserTrap1113 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1113."
+ ::= { s571 1113 }
+
+s571UserTrap1114 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1114."
+ ::= { s571 1114 }
+
+s571UserTrap1115 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1115."
+ ::= { s571 1115 }
+
+s571UserTrap1116 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1116."
+ ::= { s571 1116 }
+
+s571UserTrap1117 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1117."
+ ::= { s571 1117 }
+
+s571UserTrap1118 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1118."
+ ::= { s571 1118 }
+
+s571UserTrap1119 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1119."
+ ::= { s571 1119 }
+
+s571UserTrap1120 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1120."
+ ::= { s571 1120 }
+
+s571UserTrap1121 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1121."
+ ::= { s571 1121 }
+
+s571UserTrap1122 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1122."
+ ::= { s571 1122 }
+
+s571UserTrap1123 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1123."
+ ::= { s571 1123 }
+
+s571UserTrap1124 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1124."
+ ::= { s571 1124 }
+
+s571UserTrap1125 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1125."
+ ::= { s571 1125 }
+
+s571UserTrap1126 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1126."
+ ::= { s571 1126 }
+
+s571UserTrap1127 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1127."
+ ::= { s571 1127 }
+
+s571UserTrap1128 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1128."
+ ::= { s571 1128 }
+
+s571UserTrap1129 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1129."
+ ::= { s571 1129 }
+
+s571UserTrap1130 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1130."
+ ::= { s571 1130 }
+
+s571UserTrap1131 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1131."
+ ::= { s571 1131 }
+
+s571UserTrap1132 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1132."
+ ::= { s571 1132 }
+
+s571UserTrap1133 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1133."
+ ::= { s571 1133 }
+
+s571UserTrap1134 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1134."
+ ::= { s571 1134 }
+
+s571UserTrap1135 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1135."
+ ::= { s571 1135 }
+
+s571UserTrap1136 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1136."
+ ::= { s571 1136 }
+
+s571UserTrap1137 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1137."
+ ::= { s571 1137 }
+
+s571UserTrap1138 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1138."
+ ::= { s571 1138 }
+
+s571UserTrap1139 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1139."
+ ::= { s571 1139 }
+
+s571UserTrap1140 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1140."
+ ::= { s571 1140 }
+
+s571UserTrap1141 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1141."
+ ::= { s571 1141 }
+
+s571UserTrap1142 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1142."
+ ::= { s571 1142 }
+
+s571UserTrap1143 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1143."
+ ::= { s571 1143 }
+
+s571UserTrap1144 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1144."
+ ::= { s571 1144 }
+
+s571UserTrap1145 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1145."
+ ::= { s571 1145 }
+
+s571UserTrap1146 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1146."
+ ::= { s571 1146 }
+
+s571UserTrap1147 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1147."
+ ::= { s571 1147 }
+
+s571UserTrap1148 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1148."
+ ::= { s571 1148 }
+
+s571UserTrap1149 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1149."
+ ::= { s571 1149 }
+
+s571UserTrap1150 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1150."
+ ::= { s571 1150 }
+
+s571UserTrap1151 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1151."
+ ::= { s571 1151 }
+
+s571UserTrap1152 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1152."
+ ::= { s571 1152 }
+
+s571UserTrap1153 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1153."
+ ::= { s571 1153 }
+
+s571UserTrap1154 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1154."
+ ::= { s571 1154 }
+
+s571UserTrap1155 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1155."
+ ::= { s571 1155 }
+
+s571UserTrap1156 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1156."
+ ::= { s571 1156 }
+
+s571UserTrap1157 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1157."
+ ::= { s571 1157 }
+
+s571UserTrap1158 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1158."
+ ::= { s571 1158 }
+
+s571UserTrap1159 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1159."
+ ::= { s571 1159 }
+
+s571UserTrap1160 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1160."
+ ::= { s571 1160 }
+
+s571UserTrap1161 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1161."
+ ::= { s571 1161 }
+
+s571UserTrap1162 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1162."
+ ::= { s571 1162 }
+
+s571UserTrap1163 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1163."
+ ::= { s571 1163 }
+
+s571UserTrap1164 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1164."
+ ::= { s571 1164 }
+
+s571UserTrap1165 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1165."
+ ::= { s571 1165 }
+
+s571UserTrap1166 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1166."
+ ::= { s571 1166 }
+
+s571UserTrap1167 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1167."
+ ::= { s571 1167 }
+
+s571UserTrap1168 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1168."
+ ::= { s571 1168 }
+
+s571UserTrap1169 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1169."
+ ::= { s571 1169 }
+
+s571UserTrap1170 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1170."
+ ::= { s571 1170 }
+
+s571UserTrap1171 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1171."
+ ::= { s571 1171 }
+
+s571UserTrap1172 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1172."
+ ::= { s571 1172 }
+
+s571UserTrap1173 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1173."
+ ::= { s571 1173 }
+
+s571UserTrap1174 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1174."
+ ::= { s571 1174 }
+
+s571UserTrap1175 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1175."
+ ::= { s571 1175 }
+
+s571UserTrap1176 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1176."
+ ::= { s571 1176 }
+
+s571UserTrap1177 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1177."
+ ::= { s571 1177 }
+
+s571UserTrap1178 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1178."
+ ::= { s571 1178 }
+
+s571UserTrap1179 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1179."
+ ::= { s571 1179 }
+
+s571UserTrap1180 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1180."
+ ::= { s571 1180 }
+
+s571UserTrap1181 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1181."
+ ::= { s571 1181 }
+
+s571UserTrap1182 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1182."
+ ::= { s571 1182 }
+
+s571UserTrap1183 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1183."
+ ::= { s571 1183 }
+
+s571UserTrap1184 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1184."
+ ::= { s571 1184 }
+
+s571UserTrap1185 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1185."
+ ::= { s571 1185 }
+
+s571UserTrap1186 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1186."
+ ::= { s571 1186 }
+
+s571UserTrap1187 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1187."
+ ::= { s571 1187 }
+
+s571UserTrap1188 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1188."
+ ::= { s571 1188 }
+
+s571UserTrap1189 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1189."
+ ::= { s571 1189 }
+
+s571UserTrap1190 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1190."
+ ::= { s571 1190 }
+
+s571UserTrap1191 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1191."
+ ::= { s571 1191 }
+
+s571UserTrap1192 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1192."
+ ::= { s571 1192 }
+
+s571UserTrap1193 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1193."
+ ::= { s571 1193 }
+
+s571UserTrap1194 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1194."
+ ::= { s571 1194 }
+
+s571UserTrap1195 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1195."
+ ::= { s571 1195 }
+
+s571UserTrap1196 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1196."
+ ::= { s571 1196 }
+
+s571UserTrap1197 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1197."
+ ::= { s571 1197 }
+
+s571UserTrap1198 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1198."
+ ::= { s571 1198 }
+
+s571UserTrap1199 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1199."
+ ::= { s571 1199 }
+
+END