diff options
Diffstat (limited to 'MIBS/audiocodes/AC-ANALOG-MIB')
| -rw-r--r-- | MIBS/audiocodes/AC-ANALOG-MIB | 1775 |
1 files changed, 1775 insertions, 0 deletions
diff --git a/MIBS/audiocodes/AC-ANALOG-MIB b/MIBS/audiocodes/AC-ANALOG-MIB new file mode 100644 index 0000000..03e0002 --- /dev/null +++ b/MIBS/audiocodes/AC-ANALOG-MIB @@ -0,0 +1,1775 @@ +
+AC-ANALOG-MIB DEFINITIONS ::= BEGIN
+
+
+ IMPORTS
+
+
+ OBJECT-TYPE,
+ MODULE-IDENTITY FROM SNMPv2-SMI
+ TAddress,
+ DisplayString,
+ DateAndTime, TEXTUAL-CONVENTION FROM SNMPv2-TC
+ IpAddress FROM RFC1155-SMI
+ Unsigned32,
+ Integer32,
+ enterprises FROM SNMPv2-SMI
+ SnmpAdminString FROM SNMP-FRAMEWORK-MIB
+ audioCodes,
+ acRegistrations,
+ acGeneric,
+ acProducts,acBoardMibs FROM AUDIOCODES-TYPES-MIB;
+
+
+acAnalog MODULE-IDENTITY
+ LAST-UPDATED "201207260446Z" --Thursday, July 26 2012
+ ORGANIZATION "AudioCodes Ltd"
+ CONTACT-INFO
+ "Postal: Support
+ AudioCodes LTD
+ 1 Hayarden Street
+ Airport City
+ Lod, ISRAEL 70151
+ Tel: 972-3-9764000
+ Fax: 972-3-9764040
+ Email: support@audiocodes.com
+ Web: www.audiocodes.com"
+
+
+ DESCRIPTION
+ ""
+
+
+
+
+ ::= {acBoardMibs 8}
+
+
+
+
+
+
+
+
+ acAnalogConfiguration OBJECT IDENTIFIER ::= {acAnalog 1}
+
+
+ acAnalogConfig OBJECT IDENTIFIER ::= {acAnalogConfiguration 1}
+
+
+ acAnalogMisc OBJECT IDENTIFIER ::= {acAnalogConfig 1}
+
+
+ acAnalogMiscCurrentDisconnectDuration OBJECT-TYPE
+ SYNTAX Unsigned32 (200..1500)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Defines the current-disconnect duration (in msec). This value
+is used in generation and detection.
+Access: Offline.
+AC INI-Param: CurrentDisconnectDuration"
+ ::= {acAnalogMisc 1}
+
+
+
+ acAnalogMiscFlashHookPeriod OBJECT-TYPE
+ SYNTAX Unsigned32 (25..3000)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Defines the flashhook period (in msec) for both analog and IP
+sides.
+
+For the analog side it defines:
+
+- The maximal hook-flash detection period (for FXS gateways).
+ A longer signal is considered offhook / onhook event.
+
+- The hook-flash generation period (for FXO gateways).
+
+For the IP side it defines the flash-hook period that is reported
+to IP.
+
+The valid range is 25 to 1500. The default value is 700 msec.
+Note: For FXO gateways, a constant of 90 msec must be added
+to the required hook-flash period. For example, to generate
+a 450 msec hook-flash, set ‘FlashHookPeriod’ to 540.
+.
+Access: Instant.
+AC INI-Param: FLASHHOOKPERIOD"
+ ::= {acAnalogMisc 2}
+
+
+
+ acAnalogMiscGroundKeyDetection OBJECT-TYPE
+ SYNTAX INTEGER {
+ disable(0)
+,
+ enable(1)
+
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enables/disables the analog ground key detection.
+0 = Disable
+1= Enable.
+Access: Offline.
+AC INI-Param: GroundKeyDetection"
+ ::= {acAnalogMisc 3}
+
+
+
+ acAuxiliaryFiles OBJECT IDENTIFIER ::= {acAnalogConfig 2}
+
+
+ acAuxiliaryFilesFxsCoefficients OBJECT-TYPE
+ SYNTAX SnmpAdminString (SIZE (0..47))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Defines the FXS loop coefficient filename.
+
+Max. 47 characters.
+AC INI-Param: FXSCOEFFILENAME"
+ ::= {acAuxiliaryFiles 1}
+
+
+
+ acAuxiliaryFilesFxoCoefficients OBJECT-TYPE
+ SYNTAX SnmpAdminString (SIZE (0..47))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Defines the FXO loop coefficient filename.
+
+Max. 47 characters.
+AC INI-Param: FXOCOEFFILENAME"
+ ::= {acAuxiliaryFiles 2}
+
+
+
+ acAnalogFxoConfig OBJECT IDENTIFIER ::= {acAnalogConfiguration 2}
+
+
+ acAnalogFxo OBJECT IDENTIFIER ::= {acAnalogFxoConfig 1}
+
+
+ acAnalogFxoFarEndDisconnectType OBJECT-TYPE
+ SYNTAX Unsigned32 (0..128)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This parameter sets the source for the acEV_FAR_END_DISCONNECTED
+event (or for the relevant control protocol event). It
+is a bit field parameter, hence (for example) if both CPT and
+current disconnect are required, the parameter should be set
+to 5.
+FarDisconnect contributor:
+1 = CPT
+2 = PolarityReversal
+4 = CurrentDisconnect
+8 = Silence.
+Access: Offline.
+AC INI-Param: FARENDDISCONNECTTYPE"
+ ::= {acAnalogFxo 1}
+
+
+
+ acAnalogFxoCountryCoefficients OBJECT-TYPE
+ SYNTAX INTEGER {
+ europe(66)
+,
+ unitedStates(70)
+
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Allows the user to modify the line characteristic (AC and DC)
+according to country.
+Access: Offline.
+AC INI-Param: CountryCoefficients"
+ ::= {acAnalogFxo 2}
+
+
+
+ acAnalogFxoDCRemover OBJECT-TYPE
+ SYNTAX INTEGER {
+ disable(0)
+,
+ enable(1)
+
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Determines whether to enable the analog DC remover in the DAA.
+
+One of the following values:
+
+0 = DC remover is disabled
+1 = DC remover is enabled.
+Access: Offline.
+AC INI-Param: EnableAnalogDCRemover"
+ ::= {acAnalogFxo 3}
+
+
+
+ acAnalogFxoDefaultLinePolarityState OBJECT-TYPE
+ SYNTAX INTEGER {
+ positive-polarity(0)
+,
+ negative-polarity(1)
+,
+ polarity-auto-detect(2)
+
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Sets the TTX pulses voltage level.
+0 = 0Vrms sinusoidal bursts
+1 = 0.5Vrms sinusoidal bursts
+2 = 1Vrms sinusoidal bursts.
+Access: Offline.
+AC INI-Param: SetDefaultLinePolarityState"
+ ::= {acAnalogFxo 4}
+
+
+
+ acAnalogFxoTxGainControl OBJECT-TYPE
+ SYNTAX Integer32 (-15..12)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Sets gain\attenuation of the FXO Tx path between -15db and 12db.
+default no gain.
+Access: Offline.
+AC INI-Param: FXOTxGainControl"
+ ::= {acAnalogFxo 5}
+
+
+
+ acAnalogFxoRxGainControl OBJECT-TYPE
+ SYNTAX Integer32 (-15..12)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Sets gain\attenuation of the FXO Rx path between -15db and 12db.
+default no gain.
+Access: Offline.
+AC INI-Param: FXORxGainControl"
+ ::= {acAnalogFxo 6}
+
+
+
+ -- ****************************************
+ -- acAnalogFxoFarEndDisconnectTone table declaration
+ -- ****************************************
+ acAnalogFxoFarEndDisconnectToneTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AcAnalogFxoFarEndDisconnectToneEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ ::= {acAnalogFxo 21}
+
+
+
+ -- ****************************************
+ -- acAnalogFxoFarEndDisconnectTone table entry
+ -- ****************************************
+ acAnalogFxoFarEndDisconnectToneEntry OBJECT-TYPE
+ SYNTAX AcAnalogFxoFarEndDisconnectToneEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX {acAnalogFxoFarEndDisconnectToneIndex}
+ ::= {acAnalogFxoFarEndDisconnectToneTable 1}
+
+
+
+ -- ****************************************
+ -- acAnalogFxoFarEndDisconnectTone TABLE
+ -- ****************************************
+ AcAnalogFxoFarEndDisconnectToneEntry ::= SEQUENCE {
+ acAnalogFxoFarEndDisconnectToneRowStatus Unsigned32,
+ acAnalogFxoFarEndDisconnectToneAction Unsigned32,
+ acAnalogFxoFarEndDisconnectToneActionResult Unsigned32,
+ acAnalogFxoFarEndDisconnectToneIndex Unsigned32,
+ acAnalogFxoFarEndDisconnectToneType INTEGER
+ }
+
+
+
+ acAnalogFxoFarEndDisconnectToneRowStatus OBJECT-TYPE
+ SYNTAX Unsigned32 (1..1)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Far End Disconnect table row-status.
+AC INI-Param: N/A"
+ ::= {acAnalogFxoFarEndDisconnectToneEntry 1}
+
+
+
+ acAnalogFxoFarEndDisconnectToneAction OBJECT-TYPE
+ SYNTAX Unsigned32 (0..0)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Far End Disconnect table action.
+AC INI-Param: N/A"
+ ::= {acAnalogFxoFarEndDisconnectToneEntry 2}
+
+
+
+ acAnalogFxoFarEndDisconnectToneActionResult OBJECT-TYPE
+ SYNTAX Unsigned32 (0..0)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Far End Disconnect table result.
+AC INI-Param: N/A"
+ ::= {acAnalogFxoFarEndDisconnectToneEntry 3}
+
+
+
+ acAnalogFxoFarEndDisconnectToneIndex OBJECT-TYPE
+ SYNTAX Unsigned32 (0..4)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table use.
+AC INI-Param: N/A"
+ ::= {acAnalogFxoFarEndDisconnectToneEntry 4}
+
+
+
+ acAnalogFxoFarEndDisconnectToneType OBJECT-TYPE
+ SYNTAX INTEGER {
+ acNullTone(0)
+,
+ acDialTone(1)
+,
+ acRingingTone(2)
+,
+ acBusyTone(3)
+,
+ acCongestionTone(4)
+,
+ acSpecialInfoTone(5)
+,
+ acWarningTone(6)
+,
+ acReorderTone(7)
+,
+ acConfirmationTone(8)
+,
+ acWaitingTone(9)
+,
+ acCallProgressCo1Tone(10)
+,
+ acCallProgressCo2Tone(11)
+,
+ acOldMilliwattTone(12)
+,
+ acNewMilliwattTone(13)
+,
+ acMessageWaitingIndicator(14)
+,
+ acStutterDialTone(15)
+,
+ acStutterOffHookWarningTone(16)
+,
+ acWaitingTone1(17)
+,
+ acComfortTone(18)
+,
+ acNAKTone(19)
+,
+ acVacantNumberTone(20)
+,
+ acSpecialConditionTone(21)
+,
+ acDialTone2(22)
+,
+ acOnHoldTone(23)
+,
+ acCallTransferDialTone(24)
+,
+ acCallForwardTone(25)
+,
+ acCreditCardServiceTone(26)
+,
+ acSpecialRecallDialTone(27)
+,
+ acAlertingTone(28)
+,
+ acNetworkCongestionTone(29)
+,
+ acWaitingTone2(30)
+,
+ acWaitingTone3(31)
+,
+ acWaitingTone4(32)
+,
+ acConfEnterTone(33)
+,
+ acConfExitTone(34)
+,
+ acConfLockTone(35)
+,
+ acConfUnlockTone(36)
+,
+ acConfTimeLimitTone(37)
+,
+ acPayphoneRecognitionTone(38)
+,
+ acCallerWaitingTone(39)
+,
+ acCNGFaxTone(40)
+,
+ acPrecConfNotifyType(41)
+,
+ acPresConfNotifyType(42)
+,
+ acPrecPreemptType(43)
+,
+ acPrecRTType(44)
+,
+ acR15reqOfANItone(45)
+,
+ acCo1Tone(200)
+,
+ acCo2Tone(201)
+,
+ acPlayRecordBeepTone(202)
+,
+ acTrunkTestingTestProgressTone(203)
+,
+ acTrunkTestingTestTone(204)
+,
+ acTrunkTestingGuardTone(205)
+,
+ acFSKTrunkTestingTone(206)
+,
+ acGeneralTrunkTestingTone1(207)
+,
+ acGeneralTrunkTestingTone2(208)
+,
+ acGeneralTrunkTestingTone3(209)
+,
+ acSpecialInfoToneFirst(210)
+,
+ acSpecialInfoToneSecond(211)
+,
+ acSpecialInfoToneThird(212)
+,
+ acTTYTone(213)
+,
+ acTT904ContinuityTone(214)
+,
+ acTTMilliwattLossMeasureTone(215)
+,
+ acCarrierDialTone(216)
+,
+ acCarrierAnswerTone(217)
+,
+ acCarrierChargingTone(218)
+,
+ acLongDistanceIndicatorTone(219)
+,
+ acSTUModemFirstTone(298)
+,
+ acSTUModemSecondTone(299)
+
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Defines which CPT types are detected as far-end disconnect.
+The CPT type is based on the acTCallProgressToneType enum.
+This is valid when FarEndDisconnectType allows CPT detection.
+
+Range = An array of up to 4 tone types.
+Access: Offline.
+AC INI-Param: DISCONNECTTONETYPE"
+ ::= {acAnalogFxoFarEndDisconnectToneEntry 5}
+
+
+
+ acAnalogFxsConfig OBJECT IDENTIFIER ::= {acAnalogConfiguration 3}
+
+
+ acAnalogFxs OBJECT IDENTIFIER ::= {acAnalogFxsConfig 1}
+
+
+ acAnalogFxsPolarityReversalType OBJECT-TYPE
+ SYNTAX INTEGER {
+ soft(0)
+,
+ hard(1)
+
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Sets the type of the polarity reversal signal used for the network
+far-end answer and disconnect indications. Smooth reversal
+prevents negative effects as non-required ringing.
+0 = Soft reverse polarity
+1 = Hard reverse polarity.
+Access: Offline.
+AC INI-Param: POLARITYREVERSALTYPE"
+ ::= {acAnalogFxs 1}
+
+
+
+ acAnalogFxsMeteringType OBJECT-TYPE
+ SYNTAX INTEGER {
+ mt12kHz(0)
+,
+ mt16kHz(1)
+,
+ mtPolarityReversal(2)
+
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Sets the metering method for charging pulses.
+0 = 12 kHz sinusoidal bursts
+1 = 16 kHz sinusoidal bursts
+2 = Polarity Reversal pulses.
+Access: Offline.
+AC INI-Param: METERINGTYPE"
+ ::= {acAnalogFxs 2}
+
+
+
+ acAnalogFxsLifeLineType OBJECT-TYPE
+ SYNTAX INTEGER {
+ acLifeLineType-Hardware-Only(0)
+,
+ acLifeLineTypeHardware-And-Link-Detection(1)
+,
+ acLifeLineType-Hardware-And-Link-And-Network-Detection(2)
+
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Defines the Lifeline phone type. The Lifeline phone is available
+(for FXS only) on port 4 in MP-104 and MP-108, on port
+2 in MP-102, on ports 1-4 in the MP-118, and on port 2 of each
+analog module in the Mediant 1000.
+0 = activate Lifeline phone on power down
+1 = activate Lifeline phone on power down or on detection of
+LAN disconnect
+2 = activate Lifeline phone on power down, or on detection
+of LAN disconnect, or on loss of ping.
+Access: Offline.
+AC INI-Param: LIFELINETYPE"
+ ::= {acAnalogFxs 3}
+
+
+
+ acAnalogFxsMinFlashHookTime OBJECT-TYPE
+ SYNTAX Unsigned32 (25..300)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Sets the minimal time (in msec) for detection of a flash-hook
+event (for FXS only). The valid range is 25 to 300. The default
+value is 300 msec.
+
+Detection is guaranteed for flash hook periods of at least
+60 msec (when setting the minimal time to 25). Flash-hook signals
+that last a shorter period of time are ignored.
+
+Note: It is recommended to reduce the detection time by 50
+msec from the desired value (e.g. if you set the value as 200
+msec, then enter 150 msec, i.e. 200 minus 50).
+.
+Access: Offline.
+AC INI-Param: MINFLASHHOOKTIME"
+ ::= {acAnalogFxs 4}
+
+
+
+ acAnalogFxsCallerIDTimingMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ disable(0)
+,
+ enable(1)
+
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Defines the Analog CallerID Timing Mode.
+
+0 = CallerID transferred between first and second rings
+1 = CallerID transferred on valid Off ring.
+Access: Offline.
+AC INI-Param: ANALOGCALLERIDTIMINGMODE"
+ ::= {acAnalogFxs 5}
+
+
+
+ acAnalogFxsBellcoreCallerIDTypeOneSubStandard OBJECT-TYPE
+ SYNTAX INTEGER {
+ bellcore-Between-Rings(0)
+,
+ bellcore-Not-Ring-Related(1)
+,
+ bellcore-Before-Ring-RP-AS(2)
+
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Selects the sub-standard of the Bellcore Caller ID type.
+
+0 = Between_Rings
+1 = Not_Ring_Related
+2 = Before_Ring_RP_AS.
+Access: Offline.
+AC INI-Param: BellcoreCallerIDTypeOneSubStandard"
+ ::= {acAnalogFxs 6}
+
+
+
+ acAnalogFxsETSICallerIDTypeOneSubStandard OBJECT-TYPE
+ SYNTAX INTEGER {
+ eTSI-Between-Rings(0)
+,
+ eTSI-Before-Ring-DT-AS(1)
+,
+ eTSI-Before-Ring-RP-AS(2)
+,
+ eTSI-Before-Ring-LR-DT-AS(3)
+,
+ eTSI-Not-Ring-Related-DT-AS(4)
+,
+ eTSI-Not-Ring-Related-RP-AS(5)
+,
+ eTSI-Not-Ring-Related-LR-DT-AS(6)
+
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Selects the number denoting the ETSI CallerID Type 1 sub-standard.
+Either:
+0 = ETSI_Between_Rings
+1 = ETSI_Before_Ring_DT_AS
+2 = ETSI_Before_Ring_RP_AS
+3 = ETSI_Before_Ring_LR_DT_AS
+4 = ETSI_Not_Ring_Related_DT_AS
+5 = ETSI_Not_Ring_Related_RP_AS
+6 = ETSI_Not_Ring_Related_LR_DT_AS.
+Access: Offline.
+AC INI-Param: ETSICallerIDTypeOneSubStandard"
+ ::= {acAnalogFxs 7}
+
+
+
+ acAnalogFxsETSIVMWITypeOneStandard OBJECT-TYPE
+ SYNTAX INTEGER {
+ eTSI-VMWI-Between-Rings(0)
+,
+ eTSI-VMWI-Before-Ring-DT-AS(1)
+,
+ eTSI-VMWI-Before-Ring-RP-AS(2)
+,
+ eTSI-VMWI-Before-Ring-LR-DT-AS(3)
+,
+ eTSI-VMWI-Not-Ring-Related-DT-AS(4)
+,
+ eTSI-VMWI-Not-Ring-Related-RP-AS(5)
+,
+ eTSI-VMWI-Not-Ring-Related-LR-DT-AS(6)
+
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Selects the number denoting the ETSI VMWI Type 1 Standard.
+Choose:
+0 = ETSI_VMWI_Between_Rings
+1 = ETSI_VMWI_Before_Ring_DT_AS
+2 = ETSI_VMWI_Before_Ring_RP_AS
+3 = ETSI_VMWI_Before_Ring_LR_DT_AS
+4 = ETSI_VMWI_Not_Ring_Related_DT_AS
+5 = ETSI_VMWI_Not_Ring_Related_RP_AS
+6 = ETSI_VMWI_Not_Ring_Related_LR_DT_AS.
+Access: Offline.
+AC INI-Param: ETSIVMWITypeOneStandard"
+ ::= {acAnalogFxs 8}
+
+
+
+ acAnalogFxsBellcoreVMWITypeOneStandard OBJECT-TYPE
+ SYNTAX INTEGER {
+ bellcore-VMWI-Between-Rings(0)
+,
+ bellcore-VMWI-Not-Ring-Related(1)
+
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Use this parameter to select the Bellcore VMWI standard.
+
+0 - Between_Rings
+1 - Not_Ring_Related.
+Access: Offline.
+AC INI-Param: BellcoreVMWITypeOneStandard"
+ ::= {acAnalogFxs 9}
+
+
+
+ acAnalogFxsDisableAutoCalibration OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Determines whether to enable the analog Autocalibration in the
+DAA.
+
+One of the following values:
+
+0 = Auto calibration is enabled
+1 = Auto calibration is disabled.
+Access: Offline.
+AC INI-Param: DisableAnalogAutoCalibration"
+ ::= {acAnalogFxs 10}
+
+
+
+ acAnalogFxsExternalLifeLinePorts OBJECT-TYPE
+ SYNTAX Unsigned32 (0..24)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Set the amount of FXS ports which will be connected to an external
+life line and will be disabled (max value is half of
+the FXS ports).
+Access: Offline.
+AC INI-Param: ExternalLifeLinePorts"
+ ::= {acAnalogFxs 11}
+
+
+
+ acAnalogFxsCountryCoefficients OBJECT-TYPE
+ SYNTAX INTEGER {
+ europe(66)
+,
+ unitedStates(70)
+
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Allows the user to modify the line characteristic (AC and DC)
+according to country.
+Access: Offline.
+AC INI-Param: FXSCountryCoefficients"
+ ::= {acAnalogFxs 12}
+
+
+
+ acAnalogFxsTTXVoltageLevel OBJECT-TYPE
+ SYNTAX INTEGER {
+ notAvailable(-1)
+,
+ ttxVoltageLevel0V(0)
+,
+ ttxVoltageLevel05(1)
+,
+ ttxVoltageLevel1V(2)
+
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Sets the TTX pulses voltage level.
+0 = 0Vrms sinusoidal bursts
+1 = 0.5Vrms sinusoidal bursts
+2 = 1Vrms sinusoidal bursts
+-1 = notAvailable.
+Access: Offline.
+AC INI-Param: AnalogTTXVoltageLevel"
+ ::= {acAnalogFxs 13}
+
+
+
+ acAnalogEMConfig OBJECT IDENTIFIER ::= {acAnalogConfiguration 4}
+
+
+ acAnalogEM OBJECT IDENTIFIER ::= {acAnalogEMConfig 1}
+
+
+ acAnalogEMVoiceType OBJECT-TYPE
+ SYNTAX INTEGER {
+ twoWire(0)
+,
+ fourWire(1)
+
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "E&M Voice Configuration Type 2 or 4 wire.
+Access: Offline.
+AC INI-Param: EnMVoiceType"
+ ::= {acAnalogEM 1}
+
+
+
+ acAnalogEMInterfaceType OBJECT-TYPE
+ SYNTAX INTEGER {
+ signaling(0)
+,
+ trunking(1)
+
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "E&M Signaling Type - Trunking or Signaling.
+Access: Offline.
+AC INI-Param: EnMSystemType"
+ ::= {acAnalogEM 2}
+
+
+
+ acAnalogEMSignalingType OBJECT-TYPE
+ SYNTAX Unsigned32 (1..5)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Set E&M standatd signaling types are described in TIA/EIA-464C.
+Access: Offline.
+AC INI-Param: EnMSignalingType"
+ ::= {acAnalogEM 3}
+
+
+
+ acAnalogEMPortRXGain OBJECT-TYPE
+ SYNTAX INTEGER {
+ disable(0)
+,
+ enable(1)
+
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Rx Gain.
+Access: Offline.
+AC INI-Param: EnMPortRXGain"
+ ::= {acAnalogEM 4}
+
+
+
+ acAnalogEMPortTXGain OBJECT-TYPE
+ SYNTAX INTEGER {
+ disable(0)
+,
+ enable(1)
+
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Tx Gain.
+Access: Offline.
+AC INI-Param: EnMPortTXGain"
+ ::= {acAnalogEM 5}
+
+
+
+ acAnalogEMCountryCoefficients OBJECT-TYPE
+ SYNTAX INTEGER {
+ unitedStates(0)
+,
+ europe(1)
+
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "E&M Country Coefficients.
+Access: Offline.
+AC INI-Param: EnMCountryCoefficients"
+ ::= {acAnalogEM 6}
+
+
+
+ acAnalogEMHookDebounceTiming OBJECT-TYPE
+ SYNTAX Unsigned32 (30..150)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Sets the on E&M hook detection debounce timing.
+Access: Offline.
+AC INI-Param: EnMhookDebounceTiming"
+ ::= {acAnalogEM 7}
+
+
+
+ acAnalogEMOffHookGlareEnable OBJECT-TYPE
+ SYNTAX INTEGER {
+ disable(0)
+,
+ enable(1)
+
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Protect the EnM port from Rx and Tx hook collision.
+Access: Offline.
+AC INI-Param: EnMOffHookGlareEnable"
+ ::= {acAnalogEM 8}
+
+
+
+ acAnalogStatus OBJECT IDENTIFIER ::= {acAnalog 2}
+
+
+ acAnalogStatusMisc OBJECT IDENTIFIER ::= {acAnalogStatus 1}
+
+
+ acAnalogStatusMiscFxsOrFxo OBJECT-TYPE
+ SYNTAX INTEGER {
+ fXO(0)
+,
+ fXS(1)
+,
+ eANDm(2)
+,
+ fXOandFXS(3)
+,
+ fXOandFXSandEM(5)
+,
+ fXOandEM(6)
+,
+ fXSandEM(7)
+
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Board is Fxs,Fxo, FXS_FXO or E&M.
+AC INI-Param: N/A"
+ ::= {acAnalogStatusMisc 1}
+
+
+
+ acAnalogStatusMiscBoardTemperature OBJECT-TYPE
+ SYNTAX Unsigned32 (0..100)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Temperature of the board in degrees Celsius, should not go higher
+then 60!.
+AC INI-Param: N/A"
+ ::= {acAnalogStatusMisc 2}
+
+
+
+ acAnalogStatusMiscAnalogChannelsCount OBJECT-TYPE
+ SYNTAX Unsigned32 (0..5000)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of the Analog channels in the board.
+AC INI-Param: N/A"
+ ::= {acAnalogStatusMisc 3}
+
+
+
+ acAnalogFxsFxo OBJECT IDENTIFIER ::= {acAnalogStatus 20}
+
+
+ -- ****************************************
+ -- acAnalogFxsFxo table declaration
+ -- ****************************************
+ acAnalogFxsFxoTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AcAnalogFxsFxoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ ::= {acAnalogFxsFxo 1}
+
+
+
+ -- ****************************************
+ -- acAnalogFxsFxo table entry
+ -- ****************************************
+ acAnalogFxsFxoEntry OBJECT-TYPE
+ SYNTAX AcAnalogFxsFxoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX {acAnalogFxsFxoIndex}
+ ::= {acAnalogFxsFxoTable 1}
+
+
+
+ -- ****************************************
+ -- acAnalogFxsFxo TABLE
+ -- ****************************************
+ AcAnalogFxsFxoEntry ::= SEQUENCE {
+ acAnalogFxsFxoIndex Unsigned32,
+ acAnalogFxsFxoType INTEGER,
+ acAnalogFxsFxoChipRevNum Unsigned32,
+ acAnalogFxsFxoHookState INTEGER
+ }
+
+
+
+ acAnalogFxsFxoIndex OBJECT-TYPE
+ SYNTAX Unsigned32 (0..24)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Index for table use.
+AC INI-Param: N/A"
+ ::= {acAnalogFxsFxoEntry 1}
+
+
+
+ acAnalogFxsFxoType OBJECT-TYPE
+ SYNTAX INTEGER {
+ fXO(0)
+,
+ fXS(1)
+,
+ eM(2)
+
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Line is Fxs, Fxo or E&M.
+AC INI-Param: N/A"
+ ::= {acAnalogFxsFxoEntry 2}
+
+
+
+ acAnalogFxsFxoChipRevNum OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Fxs/Fxo's Chip revision number.
+AC INI-Param: N/A"
+ ::= {acAnalogFxsFxoEntry 3}
+
+
+
+ acAnalogFxsFxoHookState OBJECT-TYPE
+ SYNTAX INTEGER {
+ onHookState(1)
+,
+ offHookState(2)
+
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The hook state of the analog line.
+AC INI-Param: N/A"
+ ::= {acAnalogFxsFxoEntry 4}
+
+
+
+ acAnalogAction OBJECT IDENTIFIER ::= {acAnalog 3}
+
+
+ acAnalogFxoAction OBJECT IDENTIFIER ::= {acAnalogAction 1}
+
+
+ -- ****************************************
+ -- acAnalogFxoLineTest table declaration
+ -- ****************************************
+ acAnalogFxoLineTestTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AcAnalogFxoLineTestEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ ::= {acAnalogFxoAction 1}
+
+
+
+ -- ****************************************
+ -- acAnalogFxoLineTest table entry
+ -- ****************************************
+ acAnalogFxoLineTestEntry OBJECT-TYPE
+ SYNTAX AcAnalogFxoLineTestEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX {acAnalogFxoLineTestIndex}
+ ::= {acAnalogFxoLineTestTable 1}
+
+
+
+ -- ****************************************
+ -- acAnalogFxoLineTest TABLE
+ -- ****************************************
+ AcAnalogFxoLineTestEntry ::= SEQUENCE {
+ acAnalogFxoLineTestIndex Unsigned32,
+ acAnalogFxoLineTestActivate INTEGER,
+ acAnalogFxoLineTestHookState INTEGER,
+ acAnalogFxoLineTestPolarityStatus INTEGER,
+ acAnalogFxoLineTestLineConnectionStatus INTEGER,
+ acAnalogFxoLineTestLineCurrent Integer32,
+ acAnalogFxoLineTestLineVoltage Integer32,
+ acAnalogFxoLineTestRingState INTEGER,
+ acAnalogFxoLineTestLinePolarity INTEGER,
+ acAnalogFxoLineTestMwiState INTEGER,
+ acAnalogFxoLineTestLastCurrentDisconnectDuration
+ Unsigned32
+ }
+
+
+
+ acAnalogFxoLineTestIndex OBJECT-TYPE
+ SYNTAX Unsigned32 (0..24)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Index for table use.
+AC INI-Param: N/A"
+ ::= {acAnalogFxoLineTestEntry 1}
+
+
+
+ acAnalogFxoLineTestActivate OBJECT-TYPE
+ SYNTAX INTEGER {
+ noTestActivated(0)
+,
+ runLineTest(1)
+,
+ lineTestDone(2)
+,
+ testFailed(3)
+
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Activate line testing in an FXO analog line according to a given
+line-index.
+AC INI-Param: N/A"
+ ::= {acAnalogFxoLineTestEntry 2}
+
+
+
+ acAnalogFxoLineTestHookState OBJECT-TYPE
+ SYNTAX INTEGER {
+ onHookState(1)
+,
+ offHookState(2)
+
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The hook state of the analog line.
+AC INI-Param: N/A"
+ ::= {acAnalogFxoLineTestEntry 3}
+
+
+
+ acAnalogFxoLineTestPolarityStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ normalPolarity(1)
+,
+ reversePolarity(2)
+,
+ notAvailable(3)
+
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The line's polarity state.
+AC INI-Param: N/A"
+ ::= {acAnalogFxoLineTestEntry 4}
+
+
+
+ acAnalogFxoLineTestLineConnectionStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ lineDisconnected(1)
+,
+ lineConnected(2)
+
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The connection's status of the line.
+AC INI-Param: N/A"
+ ::= {acAnalogFxoLineTestEntry 5}
+
+
+
+ acAnalogFxoLineTestLineCurrent OBJECT-TYPE
+ SYNTAX Integer32 (-1..24)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The line's current [ma].
+AC INI-Param: N/A"
+ ::= {acAnalogFxoLineTestEntry 6}
+
+
+
+ acAnalogFxoLineTestLineVoltage OBJECT-TYPE
+ SYNTAX Integer32 (-128..128)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The line's voltage [V].
+AC INI-Param: N/A"
+ ::= {acAnalogFxoLineTestEntry 7}
+
+
+
+ acAnalogFxoLineTestRingState OBJECT-TYPE
+ SYNTAX INTEGER {
+ off(1)
+,
+ on(2)
+
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The Ring's State.
+AC INI-Param: N/A"
+ ::= {acAnalogFxoLineTestEntry 8}
+
+
+
+ acAnalogFxoLineTestLinePolarity OBJECT-TYPE
+ SYNTAX INTEGER {
+ positive(1)
+,
+ negative(2)
+
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The line's polarity state.
+AC INI-Param: N/A"
+ ::= {acAnalogFxoLineTestEntry 9}
+
+
+
+ acAnalogFxoLineTestMwiState OBJECT-TYPE
+ SYNTAX INTEGER {
+ off(1)
+,
+ on(2)
+
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Mwi's state.
+AC INI-Param: N/A"
+ ::= {acAnalogFxoLineTestEntry 10}
+
+
+
+ acAnalogFxoLineTestLastCurrentDisconnectDuration OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Last current disconnect duration in msec.
+AC INI-Param: N/A"
+ ::= {acAnalogFxoLineTestEntry 11}
+
+
+
+ acAnalogFxsAction OBJECT IDENTIFIER ::= {acAnalogAction 2}
+
+
+ -- ****************************************
+ -- acAnalogFxsLineTest table declaration
+ -- ****************************************
+ acAnalogFxsLineTestTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AcAnalogFxsLineTestEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ ::= {acAnalogFxsAction 1}
+
+
+
+ -- ****************************************
+ -- acAnalogFxsLineTest table entry
+ -- ****************************************
+ acAnalogFxsLineTestEntry OBJECT-TYPE
+ SYNTAX AcAnalogFxsLineTestEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX {acAnalogFxsLineTestIndex}
+ ::= {acAnalogFxsLineTestTable 1}
+
+
+
+ -- ****************************************
+ -- acAnalogFxsLineTest TABLE
+ -- ****************************************
+ AcAnalogFxsLineTestEntry ::= SEQUENCE {
+ acAnalogFxsLineTestIndex Unsigned32,
+ acAnalogFxsLineTestActivate INTEGER,
+ acAnalogFxsLineTestHookState INTEGER,
+ acAnalogFxsLineTestRingState INTEGER,
+ acAnalogFxsLineTestPolarityStatus INTEGER,
+ acAnalogFxsLineTestMessageWaitingIndication INTEGER,
+ acAnalogFxsLineTestLineCurrentReading Unsigned32,
+ acAnalogFxsLineTestLineVoltageReading Integer32,
+ acAnalogFxsLineTestAnalogVoltageReading Unsigned32,
+ acAnalogFxsLineTestRingVoltageReading Integer32,
+ acAnalogFxsLineTestLongLineCurrentReading Unsigned32
+ }
+
+
+
+ acAnalogFxsLineTestIndex OBJECT-TYPE
+ SYNTAX Unsigned32 (0..24)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Index for table use.
+AC INI-Param: N/A"
+ ::= {acAnalogFxsLineTestEntry 1}
+
+
+
+ acAnalogFxsLineTestActivate OBJECT-TYPE
+ SYNTAX INTEGER {
+ noTestActivated(0)
+,
+ runLineTest(1)
+,
+ lineTestDone(2)
+,
+ testFailed(3)
+
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Activate line testing in a FXS analog line according to a given
+line-index.
+AC INI-Param: N/A"
+ ::= {acAnalogFxsLineTestEntry 2}
+
+
+
+ acAnalogFxsLineTestHookState OBJECT-TYPE
+ SYNTAX INTEGER {
+ onHookState(1)
+,
+ offHookState(2)
+
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The hook state of the analog line.
+AC INI-Param: N/A"
+ ::= {acAnalogFxsLineTestEntry 3}
+
+
+
+ acAnalogFxsLineTestRingState OBJECT-TYPE
+ SYNTAX INTEGER {
+ offRingState(1)
+,
+ onRingState(2)
+
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Line's ring state.
+AC INI-Param: N/A"
+ ::= {acAnalogFxsLineTestEntry 4}
+
+
+
+ acAnalogFxsLineTestPolarityStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ normalPolarity(1)
+,
+ reversePolarity(2)
+
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Line's reversal-polarity.
+AC INI-Param: N/A"
+ ::= {acAnalogFxsLineTestEntry 5}
+
+
+
+ acAnalogFxsLineTestMessageWaitingIndication OBJECT-TYPE
+ SYNTAX INTEGER {
+ noWaitingMessage(1)
+,
+ waitingMessage(2)
+
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Line's messgae waiting indication state.
+AC INI-Param: N/A"
+ ::= {acAnalogFxsLineTestEntry 6}
+
+
+
+ acAnalogFxsLineTestLineCurrentReading OBJECT-TYPE
+ SYNTAX Unsigned32 (0..3000)
+ MAX-ACCESS read-only
+ STATUS obsolete
+ DESCRIPTION
+ "The Line current reading in 10ua units.
+This test is supported only in line no. 0.
+Not supported on MP500.
+In case of MP124 this test is supported in all ports except
+ports 2 and 3.
+As of version 6.6 this is an obsolete parameter.
+AC INI-Param: N/A"
+ ::= {acAnalogFxsLineTestEntry 7}
+
+
+
+ acAnalogFxsLineTestLineVoltageReading OBJECT-TYPE
+ SYNTAX Integer32 (-6000..6000)
+ MAX-ACCESS read-only
+ STATUS obsolete
+ DESCRIPTION
+ "The Line voltage reading in 10mV units.
+In case of MP124 the Line voltage reading in 1V units.
+This test is supported only in line no. 0.
+Not supported on MP500.
+In case of MP124 this test is supported in all ports except
+ports 2 and 3.
+As of version 6.6 this is an obsolete parameter.
+AC INI-Param: N/A"
+ ::= {acAnalogFxsLineTestEntry 8}
+
+
+
+ acAnalogFxsLineTestAnalogVoltageReading OBJECT-TYPE
+ SYNTAX Unsigned32 (300..340)
+ MAX-ACCESS read-only
+ STATUS obsolete
+ DESCRIPTION
+ "The current analog voltage reading in 10mV units.
+his test is supported only in line no. 0.
+Not supported on MP500.
+In case of MP124 this test is supported in all ports except
+ports 2 and 3.
+As of version 6.6 this is an obsolete parameter.
+AC INI-Param: N/A"
+ ::= {acAnalogFxsLineTestEntry 9}
+
+
+
+ acAnalogFxsLineTestRingVoltageReading OBJECT-TYPE
+ SYNTAX Integer32 (-13000..13000)
+ MAX-ACCESS read-only
+ STATUS obsolete
+ DESCRIPTION
+ "The current ring voltage reading in 10mV units.
+This test is supported only in line no. 0.
+Not supported on MP500.
+In case of MP124 this test is supported in all ports except
+ports 2 and 3.
+As of version 6.6 this is an obsolete parameter.
+AC INI-Param: N/A"
+ ::= {acAnalogFxsLineTestEntry 10}
+
+
+
+ acAnalogFxsLineTestLongLineCurrentReading OBJECT-TYPE
+ SYNTAX Unsigned32 (0..4000)
+ MAX-ACCESS read-only
+ STATUS obsolete
+ DESCRIPTION
+ "The current long line reading in 10ua units.
+This test is supported only in line no. 0.
+Not supported on MP500.
+In case of MP124 this test is supported in all ports except
+ports 2 and 3.
+As of version 6.6 this is an obsolete parameter.
+AC INI-Param: N/A"
+ ::= {acAnalogFxsLineTestEntry 11}
+
+
+
+ acAnalogCommonAction OBJECT IDENTIFIER ::= {acAnalogAction 3}
+
+
+ -- ****************************************
+ -- acAnalogCommonChannel table declaration
+ -- ****************************************
+ acAnalogCommonChannelTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AcAnalogCommonChannelEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table for common channels operations."
+ ::= {acAnalogCommonAction 1}
+
+
+
+ -- ****************************************
+ -- acAnalogCommonChannel table entry
+ -- ****************************************
+ acAnalogCommonChannelEntry OBJECT-TYPE
+ SYNTAX AcAnalogCommonChannelEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX {acAnalogCommonChannelIndex}
+ ::= {acAnalogCommonChannelTable 1}
+
+
+
+ -- ****************************************
+ -- acAnalogCommonChannel TABLE
+ -- ****************************************
+ AcAnalogCommonChannelEntry ::= SEQUENCE {
+ acAnalogCommonChannelIndex Unsigned32,
+ acAnalogCommonChannelAction INTEGER
+ }
+
+
+
+ acAnalogCommonChannelIndex OBJECT-TYPE
+ SYNTAX Unsigned32 (0..5000)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Index for table use, the current channel.
+AC INI-Param: N/A"
+ ::= {acAnalogCommonChannelEntry 1}
+
+
+
+ acAnalogCommonChannelAction OBJECT-TYPE
+ SYNTAX INTEGER {
+ noAction(0)
+,
+ reset(1)
+
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "An action to make on the current channel, The Reset action is
+for Analog channels only.
+AC INI-Param: N/A"
+ ::= {acAnalogCommonChannelEntry 2}
+
+
+
+ acAnalogLegs OBJECT IDENTIFIER ::= {acAnalogStatus 21}
+
+
+ -- ****************************************
+ -- acAnalogLegs table declaration
+ -- ****************************************
+ acAnalogLegsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AcAnalogLegsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ ::= {acAnalogLegs 1}
+
+
+
+ -- ****************************************
+ -- acAnalogLegs table entry
+ -- ****************************************
+ acAnalogLegsEntry OBJECT-TYPE
+ SYNTAX AcAnalogLegsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX {acAnalogLegsLegIndex}
+ ::= {acAnalogLegsTable 1}
+
+
+
+ -- ****************************************
+ -- acAnalogLegs TABLE
+ -- ****************************************
+ AcAnalogLegsEntry ::= SEQUENCE {
+ acAnalogLegsLegIndex Unsigned32,
+ acAnalogLegsCallIndex Unsigned32,
+ acAnalogLegsAnalogType INTEGER,
+ acAnalogLegsEchoCanceller INTEGER,
+ acAnalogLegsHighPassFilter INTEGER,
+ acAnalogLegsDTMFDetection INTEGER,
+ acAnalogLegsVoiceVolume Unsigned32,
+ acAnalogLegsInputGain Unsigned32,
+ acAnalogLegsLegName SnmpAdminString
+ }
+
+
+
+ acAnalogLegsLegIndex OBJECT-TYPE
+ SYNTAX Unsigned32 (0..5000)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Decribes The Digital EndPoint In A Call.
+AC INI-Param: N/A"
+ ::= {acAnalogLegsEntry 1}
+
+
+
+ acAnalogLegsCallIndex OBJECT-TYPE
+ SYNTAX Unsigned32 (0..5000)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Decribes The Call which The Rtp EndPoint Participant In It.
+AC INI-Param: N/A"
+ ::= {acAnalogLegsEntry 2}
+
+
+
+ acAnalogLegsAnalogType OBJECT-TYPE
+ SYNTAX INTEGER {
+ fxs(1)
+,
+ fxo(2)
+
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Describs whether the board is FXS or FXO.
+AC INI-Param: N/A"
+ ::= {acAnalogLegsEntry 3}
+
+
+
+ acAnalogLegsEchoCanceller OBJECT-TYPE
+ SYNTAX INTEGER {
+ disable(0)
+,
+ enable(1)
+
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Enables or Disables the Echo Canceller.
+AC INI-Param: N/A"
+ ::= {acAnalogLegsEntry 4}
+
+
+
+ acAnalogLegsHighPassFilter OBJECT-TYPE
+ SYNTAX INTEGER {
+ disable(0)
+,
+ enable(1)
+
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Enables or Disables theHigh Pass Filter.
+AC INI-Param: N/A"
+ ::= {acAnalogLegsEntry 5}
+
+
+
+ acAnalogLegsDTMFDetection OBJECT-TYPE
+ SYNTAX INTEGER {
+ disable(0)
+,
+ enable(1)
+
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Enables or Disables the DTMF Detection.
+AC INI-Param: N/A"
+ ::= {acAnalogLegsEntry 6}
+
+
+
+ acAnalogLegsVoiceVolume OBJECT-TYPE
+ SYNTAX Unsigned32 (0..20000)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Describs the volume of the voice in dB.
+AC INI-Param: N/A"
+ ::= {acAnalogLegsEntry 7}
+
+
+
+ acAnalogLegsInputGain OBJECT-TYPE
+ SYNTAX Unsigned32 (0..20000)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Describes the Input Gain on the leg in dB.
+AC INI-Param: N/A"
+ ::= {acAnalogLegsEntry 8}
+
+
+
+ acAnalogLegsLegName OBJECT-TYPE
+ SYNTAX SnmpAdminString (SIZE (0..64))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Describes the Leg Name as in the Control Protocol.
+AC INI-Param: N/A"
+ ::= {acAnalogLegsEntry 9}
+
+
+
+
+
+END
|