diff options
Diffstat (limited to 'MIBS/avtech/ROOMALERT11E-MIB')
| -rw-r--r-- | MIBS/avtech/ROOMALERT11E-MIB | 693 |
1 files changed, 693 insertions, 0 deletions
diff --git a/MIBS/avtech/ROOMALERT11E-MIB b/MIBS/avtech/ROOMALERT11E-MIB new file mode 100644 index 0000000..8dc9f02 --- /dev/null +++ b/MIBS/avtech/ROOMALERT11E-MIB @@ -0,0 +1,693 @@ +-- +--defines ROOMALERT11E-MIB for SNMP agent extension of Room Alert 11E +--Contents: Global Registration Module +-- Room Alert OIDs - Enterprise 20916 +--Version: 1.1.3 +--Date: 9 January 2014 +--Developed By: AVTECH Software, Inc. + +-- +--Copyright (c) 2014 AVTECH Software, Inc. +-- + +ROOMALERT11E-MIB DEFINITIONS ::= BEGIN + + +IMPORTS + enterprises, IpAddress, Counter, TimeTicks + FROM RFC1155-SMI + OBJECT-TYPE + FROM RFC-1212 + TRAP-TYPE + FROM RFC-1215; + + +avtech OBJECT IDENTIFIER ::= { enterprises 20916 } +products OBJECT IDENTIFIER ::= { avtech 1 } +roomalert11E OBJECT IDENTIFIER ::= { products 3 } +sensors OBJECT IDENTIFIER ::= { roomalert11E 1 } +traps OBJECT IDENTIFIER ::= { roomalert11E 2 } +thresholds OBJECT IDENTIFIER ::= { roomalert11E 3 } +channel1 OBJECT IDENTIFIER ::= { sensors 1 } +channel2 OBJECT IDENTIFIER ::= { sensors 2 } +channel3 OBJECT IDENTIFIER ::= { sensors 3 } +channel4 OBJECT IDENTIFIER ::= { sensors 4 } +channels OBJECT IDENTIFIER ::= { thresholds 1 } +channels1 OBJECT IDENTIFIER ::= { channels 1 } +channels2 OBJECT IDENTIFIER ::= { channels 2 } +channels3 OBJECT IDENTIFIER ::= { channels 3 } +channels4 OBJECT IDENTIFIER ::= { channels 4 } + +-- Room Alert 11E MIB +-- Parameters + +sensor1-1 OBJECT-TYPE + SYNTAX INTEGER(0..1) + ACCESS read-only + STATUS mandatory + DESCRIPTION "The reading for internal switch sensor 1 (0 = OPEN, 1 = CLOSED)." +::= { channel1 1 } + +sensor1-2 OBJECT-TYPE + SYNTAX INTEGER(0..1) + ACCESS read-only + STATUS mandatory + DESCRIPTION "The reading for internal switch sensor 2 (0 = OPEN, 1 = CLOSED)." +::= { channel1 2 } + +sensor1-3 OBJECT-TYPE + SYNTAX INTEGER(0..1) + ACCESS read-only + STATUS mandatory + DESCRIPTION "The reading for internal switch sensor 3 (0 = OPEN, 1 = CLOSED)." +::= { channel1 3 } + +sensor1-4 OBJECT-TYPE + SYNTAX INTEGER(0..1) + ACCESS read-only + STATUS mandatory + DESCRIPTION "The reading for internal switch sensor 4 (0 = OPEN, 1 = CLOSED)." +::= { channel1 4 } + +sensor1-5 OBJECT-TYPE + SYNTAX INTEGER(0..1) + ACCESS read-only + STATUS mandatory + DESCRIPTION "The reading for internal switch sensor 5 (0 = OPEN, 1 = CLOSED)." +::= { channel1 5 } + +sensor1-6 OBJECT-TYPE + SYNTAX INTEGER(0..1) + ACCESS read-only + STATUS mandatory + DESCRIPTION "The reading for internal switch sensor 6 (0 = OPEN, 1 = CLOSED)." +::= { channel1 6 } + +sensor1-7 OBJECT-TYPE + SYNTAX INTEGER(0..1) + ACCESS read-only + STATUS mandatory + DESCRIPTION "The reading for internal switch sensor 7 (0 = OPEN, 1 = CLOSED)." +::= { channel1 7 } + +sensor1-8 OBJECT-TYPE + SYNTAX INTEGER(0..1) + ACCESS read-only + STATUS mandatory + DESCRIPTION "The reading for internal switch sensor 8 (0 = OPEN, 1 = CLOSED)." +::= { channel1 8 } + +switch-label-1 OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION "The label for switch sensor 1" +::= { channel1 9 } + +switch-label-2 OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION "The label for switch sensor 2" +::= { channel1 10 } + +switch-label-3 OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION "The label for switch sensor 3" +::= { channel1 11 } + +switch-label-4 OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION "The label for switch sensor 4" +::= { channel1 12 } + +switch-label-5 OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION "The label for switch sensor 5" +::= { channel1 13 } + +switch-label-6 OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION "The label for switch sensor 6" +::= { channel1 14 } + +switch-label-7 OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION "The label for switch sensor 7" +::= { channel1 15 } + +switch-label-8 OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION "The label for switch sensor 8" +::= { channel1 16 } + +sensor2-1 OBJECT-TYPE + SYNTAX INTEGER(0..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION "The reading for sensor 2-1. If a temp or temp/humidity sensor is connected, value will be current temperature in Celsius." +::= { channel2 1 } + +sensor2-2 OBJECT-TYPE + SYNTAX INTEGER(0..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION "The reading for sensor 2-2. If a temp or temp/humidity sensor is connected, value will be current temperature in Fahrenheit." +::= { channel2 2 } + +sensor2-3 OBJECT-TYPE + SYNTAX INTEGER(0..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION "The reading for sensor 2-3. If temp/humidity sensor is connected, value will be current %RH." +::= { channel2 3 } + +sensor2-4 OBJECT-TYPE + SYNTAX INTEGER(0..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION "The reading for sensor 2-4. If temp/humidity sensor is connected, value will be current Heat Index in Fahrenheit." +::= { channel2 4 } + +sensor2-5 OBJECT-TYPE + SYNTAX INTEGER(0..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION "The reading for sensor 2-5. If temp/humidity sensor is connected, value will be current Heat Index in Celsius." +::= { channel2 5 } + +sensor2-6-label OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION "The label of this sensor" +::= { channel2 6} + +sensor3-1 OBJECT-TYPE + SYNTAX INTEGER(0..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION "The reading for sensor 3-1. If a temp or temp/humidity sensor is connected, value will be current temperature in Celsius." +::= { channel3 1 } + +sensor3-2 OBJECT-TYPE + SYNTAX INTEGER(0..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION "The reading for sensor 3-2. If a temp or temp/humidity sensor is connected, value will be current temperature in Fahrenheit." +::= { channel3 2 } + +sensor3-3 OBJECT-TYPE + SYNTAX INTEGER(0..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION "The reading for sensor 3-3. If temp/humidity sensor is connected, value will be current %RH." +::= { channel3 3 } + +sensor3-4 OBJECT-TYPE + SYNTAX INTEGER(0..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION "The reading for sensor 3-4. If temp/humidity sensor is connected, value will be current Heat Index in Fahrenheit." +::= { channel3 4 } + +sensor3-5 OBJECT-TYPE + SYNTAX INTEGER(0..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION "The reading for sensor 3-5. If temp/humidity sensor is connected, value will be current Heat Index in Celsius." +::= { channel3 5 } + +sensor3-6-label OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION "The label of this sensor" +::= { channel3 6} + +sensor4-1 OBJECT-TYPE + SYNTAX INTEGER(0..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION "The reading for sensor 4-1. If a temp or temp/humidity sensor is connected, value will be current temperature in Celsius." +::= { channel4 1 } + +sensor4-2 OBJECT-TYPE + SYNTAX INTEGER(0..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION "The reading for sensor 4-2. If a temp or temp/humidity sensor is connected, value will be current temperature in Fahrenheit." +::= { channel4 2 } + +sensor4-3 OBJECT-TYPE + SYNTAX INTEGER(0..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION "The reading for sensor 4-3. If temp/humidity sensor is connected, value will be current %RH." +::= { channel4 3 } + +sensor4-4 OBJECT-TYPE + SYNTAX INTEGER(0..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION "The reading for sensor 4-4. If temp/humidity sensor is connected, value will be current Heat Index in Fahrenheit." +::= { channel4 4 } + +sensor4-5 OBJECT-TYPE + SYNTAX INTEGER(0..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION "The reading for sensor 4-5. If temp/humidity sensor is connected, value will be current Heat Index in Celsius." +::= { channel4 5 } + +sensor4-6-label OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION "The label of this sensor" +::= { channel4 6} + +alarm1 OBJECT-TYPE + SYNTAX INTEGER(0..255) + ACCESS read-only + STATUS mandatory + DESCRIPTION "Alarm for sensor channel 1. The binary equivalent of the decimal number displayed will indicate which switch sensors are currently in an alarm state (0 = sensor ok, 1 = sensor in alarm state). For example, if switch sensors 1 and 4 are in alarm state, the value displayed will be 9, which equals 00001001 in binary." +::= { traps 1 } + +alarm2 OBJECT-TYPE + SYNTAX INTEGER(0..255) + ACCESS read-only + STATUS mandatory + DESCRIPTION "Alarm for sensor channel 2. If a digital temperature/humidity or digital temperature sensor is connected to this channel, 0 = sensor ok, 1 = high temp alarm, 2 = low temp alarm, 3 = humidity alarm. If a Switch Sensor Expansion box is connected, the binary equivalent of the decimal number displayed will indicate which switch sensors are currently in an alarm state (0 = sensor ok, 1 = sensor in alarm state). For example, if switch sensors 1 and 4 are in alarm state, the value displayed will be 9, which equals 00001001 in binary." +::= { traps 2 } + +alarm3 OBJECT-TYPE + SYNTAX INTEGER(0..255) + ACCESS read-only + STATUS mandatory + DESCRIPTION "Alarm for sensor channel 3. If a digital temperature/humidity or digital temperature sensor is connected to this channel, 0 = sensor ok, 1 = high temp alarm, 2 = low temp alarm, 3 = humidity alarm. If a Switch Sensor Expansion box is connected, the binary equivalent of the decimal number displayed will indicate which switch sensors are currently in an alarm state (0 = sensor ok, 1 = sensor in alarm state). For example, if switch sensors 1 and 4 are in alarm state, the value displayed will be 9, which equals 00001001 in binary." +::= { traps 3 } + +alarm4 OBJECT-TYPE + SYNTAX INTEGER(0..255) + ACCESS read-only + STATUS mandatory + DESCRIPTION "Alarm for sensor channel 4. If a digital temperature/humidity or digital temperature sensor is connected to this channel, 0 = sensor ok, 1 = high temp alarm, 2 = low temp alarm, 3 = humidity alarm. If a Switch Sensor Expansion box is connected, the binary equivalent of the decimal number displayed will indicate which switch sensors are currently in an alarm state (0 = sensor ok, 1 = sensor in alarm state). For example, if switch sensors 1 and 4 are in alarm state, the value displayed will be 9, which equals 00001001 in binary." +::= { traps 4 } + +alarmMessage1 OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION "Alarm Message from sensor channel 1 (Internal)" +::= { traps 5 } + +alarmMessage2 OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION "Alarm Message from sensor channel 2 (External)" +::= { traps 6 } + +alarmMessage3 OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION "Alarm Message from sensor channel 3 (External)" +::= { traps 7 } + +alarmMessage4 OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION "Alarm Message from sensor channel 4 (External)" +::= { traps 8 } + +threshold1-1 OBJECT-TYPE + SYNTAX INTEGER(0..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION "Threshold 1 defined for Channel 1" +::= { channels1 1 } + +threshold1-2 OBJECT-TYPE + SYNTAX INTEGER(0..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION "Threshold 2 defined for Channel 1" +::= { channels1 2 } + +threshold1-3 OBJECT-TYPE + SYNTAX INTEGER(0..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION "Threshold 3 defined for Channel 1" +::= { channels1 3 } + +threshold1-4 OBJECT-TYPE + SYNTAX INTEGER(0..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION "Threshold 4 defined for Channel 1" +::= { channels1 4 } + +threshold1-5 OBJECT-TYPE + SYNTAX INTEGER(0..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION "Threshold 5 defined for Channel 1" +::= { channels1 5 } + +threshold1-6 OBJECT-TYPE + SYNTAX INTEGER(0..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION "Threshold 6 defined for Channel 1" +::= { channels1 6 } + +threshold1-7 OBJECT-TYPE + SYNTAX INTEGER(0..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION "Threshold 7 defined for Channel 1" +::= { channels1 7 } + +threshold1-8 OBJECT-TYPE + SYNTAX INTEGER(0..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION "Threshold 8 defined for Channel 1" +::= { channels1 8 } + +threshold2-1 OBJECT-TYPE + SYNTAX INTEGER(0..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION "Threshold 1 defined for Channel 2" +::= { channels2 1 } + +threshold2-2 OBJECT-TYPE + SYNTAX INTEGER(0..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION "Threshold 2 defined for Channel 2" +::= { channels2 2 } + +threshold2-3 OBJECT-TYPE + SYNTAX INTEGER(0..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION "Threshold 3 defined for Channel 2" +::= { channels2 3 } + +threshold2-4 OBJECT-TYPE + SYNTAX INTEGER(0..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION "Threshold 4 defined for Channel 2" +::= { channels2 4 } + +threshold3-1 OBJECT-TYPE + SYNTAX INTEGER(0..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION "Threshold 1 defined for Channel 3" +::= { channels3 1 } + +threshold3-2 OBJECT-TYPE + SYNTAX INTEGER(0..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION "Threshold 2 defined for Channel 3" +::= { channels3 2 } + +threshold3-3 OBJECT-TYPE + SYNTAX INTEGER(0..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION "Threshold 3 defined for Channel 3" +::= { channels3 3 } + +threshold3-4 OBJECT-TYPE + SYNTAX INTEGER(0..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION "Threshold 4 defined for Channel 3" +::= { channels3 4 } + +threshold4-1 OBJECT-TYPE + SYNTAX INTEGER(0..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION "Threshold 1 defined for Channel 4" +::= { channels4 1 } + +threshold4-2 OBJECT-TYPE + SYNTAX INTEGER(0..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION "Threshold 2 defined for Channel 4" +::= { channels4 2 } + +threshold4-3 OBJECT-TYPE + SYNTAX INTEGER(0..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION "Threshold 3 defined for Channel 4" +::= { channels4 3 } + +threshold4-4 OBJECT-TYPE + SYNTAX INTEGER(0..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION "Threshold 4 defined for Channel 4" +::= { channels4 4 } + + +-- ROOMALERT11E TRAPS + +tempAlarm1-11e TRAP-TYPE + ENTERPRISE roomalert11E + VARIABLES { alarmMessage2, sensor2-1, sensor2-2, sensor2-1 } + DESCRIPTION "A tempAlarm1 trap signifies that the current + temperature on external sensor 1 is outside the + defined high or low threshold." +::= 1 + +room-alert-11E-SNMP-trap TRAP-TYPE + ENTERPRISE roomalert11E + VARIABLES { alarmMessage1,alarmMessage2,alarmMessage3,alarmMessage4 } + DESCRIPTION "A Room Alert 11E SNMP Trap indicates that an alarm + condition has occurred on the sensor inidcated + by the alarmMessage variable." +::= 2 + +tempAlarm2-11e TRAP-TYPE + ENTERPRISE roomalert11E + VARIABLES { alarmMessage3, sensor3-1, sensor3-2, sensor3-1 } + DESCRIPTION "A tempAlarm2 trap signifies that the current + temperature on external sensor 2 is outside the + defined high or low threshold." +::= 3 + +tempClear2-11e TRAP-TYPE + ENTERPRISE roomalert11E + VARIABLES { alarmMessage3, sensor3-1, sensor3-2, sensor3-1 } + DESCRIPTION "A tempClear2 trap signifies that the current + temperature on external sensor 2 has returned to + a normal condition and is within the defined + high or low threshold." +::= 4 + +tempAlarm3-11e TRAP-TYPE + ENTERPRISE roomalert11E + VARIABLES { alarmMessage4, sensor4-1, sensor4-2, sensor4-1 } + DESCRIPTION "A tempAlarm3 trap signifies that the current + temperature on external sensor 3 is outside the + defined high or low threshold." +::= 5 + +tempClear3-11e TRAP-TYPE + ENTERPRISE roomalert11E + VARIABLES { alarmMessage4, sensor4-1, sensor4-2, sensor4-1 } + DESCRIPTION "A tempClear3 trap signifies that the current + temperature on external sensor 3 has returned to + a normal condition and is within the defined + high or low threshold." +::= 6 + +humidityAlarm1-11e TRAP-TYPE + ENTERPRISE roomalert11E + VARIABLES { alarmMessage2, sensor2-1, sensor2-2, sensor2-3 } + DESCRIPTION "A humidityAlarm1 trap signifies that the current + humidity on external sensor 1 is outside the + defined high or low threshold." +::= 7 + +humidityClear1-11e TRAP-TYPE + ENTERPRISE roomalert11E + VARIABLES { alarmMessage2, sensor2-1, sensor2-2, sensor2-3 } + DESCRIPTION "A humidityClear1 trap signifies that the current + humidity on external sensor 1 has returned to + a normal condition and is within the defined + high or low threshold." +::= 8 + +humidityAlarm2-11e TRAP-TYPE + ENTERPRISE roomalert11E + VARIABLES { alarmMessage3, sensor3-1, sensor3-2, sensor3-3 } + DESCRIPTION "A humidityAlarm2 trap signifies that the current + humidity on external sensor 2 is outside the + defined high or low threshold." +::= 9 + +humidityClear2-11e TRAP-TYPE + ENTERPRISE roomalert11E + VARIABLES { alarmMessage3, sensor3-1, sensor3-2, sensor3-3 } + DESCRIPTION "A humidityClear2 trap signifies that the current + humidity on external sensor 2 has returned to + a normal condition and is within the defined + high or low threshold." +::= 10 + +humidityAlarm3-11e TRAP-TYPE + ENTERPRISE roomalert11E + VARIABLES { alarmMessage4, sensor4-1, sensor4-2, sensor4-3 } + DESCRIPTION "A humidityAlarm3 trap signifies that the current + humidity on external sensor 3 is outside the + defined high or low threshold." +::= 11 + +humidityClear3-11e TRAP-TYPE + ENTERPRISE roomalert11E + VARIABLES { alarmMessage4, sensor4-1, sensor4-2, sensor4-3 } + DESCRIPTION "A humidityClear3 trap signifies that the current + humidity on external sensor 3 has returned to + a normal condition and is within the defined + high or low threshold." +::= 12 + +switchAlarm1-11e TRAP-TYPE + ENTERPRISE roomalert11E + VARIABLES { alarmMessage1, sensor1-1, sensor1-1, sensor1-1 } + DESCRIPTION "A switchAlarm1 trap signifies that switch sensor 1 + is in an alarm state." +::= 13 + +switchClear1-11e TRAP-TYPE + ENTERPRISE roomalert11E + VARIABLES { alarmMessage1, sensor1-1, sensor1-1, sensor1-1 } + DESCRIPTION "A switchClear1 trap signifies that the switch sensor 1 + has returned to a normal state." +::= 14 + +switchAlarm2-11e TRAP-TYPE + ENTERPRISE roomalert11E + VARIABLES { alarmMessage1, sensor1-2, sensor1-2, sensor1-2 } + DESCRIPTION "A switchAlarm2 trap signifies that switch sensor 2 + is in an alarm state." +::= 15 + +switchClear2-11e TRAP-TYPE + ENTERPRISE roomalert11E + VARIABLES { alarmMessage1, sensor1-2, sensor1-2, sensor1-2 } + DESCRIPTION "A switchClear2 trap signifies that the switch sensor 2 + has returned to a normal state." +::= 16 + +switchAlarm3-11e TRAP-TYPE + ENTERPRISE roomalert11E + VARIABLES { alarmMessage1, sensor1-3, sensor1-3, sensor1-3 } + DESCRIPTION "A switchAlarm1 trap signifies that switch sensor 1 + is in an alarm state." +::= 17 + +switchClear3-11e TRAP-TYPE + ENTERPRISE roomalert11E + VARIABLES { alarmMessage1, sensor1-3, sensor1-3, sensor1-3 } + DESCRIPTION "A switchClear3 trap signifies that the switch sensor 3 + has returned to a normal state." +::= 18 + +switchAlarm4-11e TRAP-TYPE + ENTERPRISE roomalert11E + VARIABLES { alarmMessage1, sensor1-4, sensor1-4, sensor1-4 } + DESCRIPTION "A switchAlarm4 trap signifies that switch sensor 4 + is in an alarm state." +::= 19 + +switchClear4-11e TRAP-TYPE + ENTERPRISE roomalert11E + VARIABLES { alarmMessage1, sensor1-4, sensor1-4, sensor1-4 } + DESCRIPTION "A switchClear4 trap signifies that the switch sensor 4 + has returned to a normal state." +::= 20 + +switchAlarm5-11e TRAP-TYPE + ENTERPRISE roomalert11E + VARIABLES { alarmMessage1, sensor1-5, sensor1-5, sensor1-5 } + DESCRIPTION "A switchAlarm5 trap signifies that switch sensor 5 + is in an alarm state." +::= 21 + +switchClear5-11e TRAP-TYPE + ENTERPRISE roomalert11E + VARIABLES { alarmMessage1, sensor1-5, sensor1-5, sensor1-5 } + DESCRIPTION "A switchClear5 trap signifies that the switch sensor 5 + has returned to a normal state." +::= 22 + +switchAlarm6-11e TRAP-TYPE + ENTERPRISE roomalert11E + VARIABLES { alarmMessage1, sensor1-6, sensor1-6, sensor1-6 } + DESCRIPTION "A switchAlarm6 trap signifies that switch sensor 6 + is in an alarm state." +::= 23 + +switchClear6-11e TRAP-TYPE + ENTERPRISE roomalert11E + VARIABLES { alarmMessage1, sensor1-6, sensor1-6, sensor1-6 } + DESCRIPTION "A switchClear6 trap signifies that the switch sensor 6 + has returned to a normal state." +::= 24 + +switchAlarm7-11e TRAP-TYPE + ENTERPRISE roomalert11E + VARIABLES { alarmMessage1, sensor1-7, sensor1-7, sensor1-7 } + DESCRIPTION "A switchAlarm7 trap signifies that switch sensor 7 + is in an alarm state." +::= 25 + +switchClear7-11e TRAP-TYPE + ENTERPRISE roomalert11E + VARIABLES { alarmMessage1, sensor1-7, sensor1-7, sensor1-7 } + DESCRIPTION "A switchClear7 trap signifies that the switch sensor 7 + has returned to a normal state." +::= 26 + +switchAlarm8-11e TRAP-TYPE + ENTERPRISE roomalert11E + VARIABLES { alarmMessage1, sensor1-8, sensor1-8, sensor1-8 } + DESCRIPTION "A switchAlarm8 trap signifies that switch sensor 8 + is in an alarm state." +::= 27 + +switchClear8-11e TRAP-TYPE + ENTERPRISE roomalert11E + VARIABLES { alarmMessage1, sensor1-8, sensor1-8, sensor1-8 } + DESCRIPTION "A switchClear8 trap signifies that the switch sensor 8 + has returned to a normal state." +::= 28 +END |